Loading...
HomeMy WebLinkAbout46952-Z opo cpG Town of Southold 2/16/2023 P.O.Box 1179 "' x+� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43856 Date: 2/16/2023 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 545 Ryder Farm Ln, Orient SCTM#: 473889 Sec/Block/Lot: 15.-4-9.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/24/2021 pursuant to which Building Permit No. 46952 dated 10/12/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alteration for laundry room to existing single family dwelling. The certificate is issued to Pugh,David&Silvestri,Tina of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46952 2/7/2022 PLUMBERS CERTIFICATION DATED 9/30/2022 I/ A AA , arado t ri d gnature TOWN OF SOUTHOLD �pSHfFatK BUILDING DEPARTMENT TOWN CLERKS OFFICE V y�o �a� 'i SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE--SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46952 Date: 10/12/2021 Permission is hereby granted to: Pugh, David 345 E 81st St Unit 10L New York, NY 10028 To: Construct kitchen and second floor interior alterations at existing single family dwelling as applied for. *Front entry addition NOT part of this permit and requires ZBA approval. At premises located at: 545 Ryder Farm Ln, Orient SCTM #473889 Sec/Block/Lot# 15.4-9.1 Pursuant to application dated 9/24/2021 and approved by the Building Inspector. To expire on 4/13/2023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $335.20 CO-ALTERATION TO DWELLING $50.00 Total: $385.20 �-�K Building Inspector OF SOUTyoI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinA)town.southold.ny.us Southold,NY 11971-0959 �yC4UN1`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: David Pugh Address: 545 Ryder Farm Ln city:Orient st: NY zip: -11957 Building Permit#: 46952 Section: 15 Block: 4 Lot: - 9.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Retrofit Electric License No: 60131 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor 1st Floor Pool New Renovation X 2nd Floor X Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 19 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 5 Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 3 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HH's & Smokes on Second Floor Inspector Signature: Date: February 7, 2022 S.Devlin-Cert Electrical Compliance Form Town Hall Annex 1 _ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 •, Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD II OCT p 3 2022 E IM Toe. CERTIFICATION ti. Date: Z� Building Permit No. - I � /� Owner:- ITAv � � Ra (Please print) Plumber:.- 6C.A- llkirkircl. . C).. (Please print) I certify that the solder used in the water supply system contains less than 2/10 of I% lead. (Plumbers Signature) Sworn to before me this 6 day of 20 >I,.-- ROBERT J ROSSETTI Notary Public State of New York NO.01R06348297 Qualified in Suffolk County Notary Public, C—puPty' T My Commission Expires Sep 26, 2024 OF SOGIyo _ 6 ( 5-2 �� S- 1�_Y_7 I f # TOWN OF SOUTHOLD BUILDING DEPT. _f50r" 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] "INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]-"'FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) :[ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O 11 REMARKS: .. _ft4g®' � �S i 'AAN ee Z 2 Z DATE I12Az INSPECTOR � q�q Y �o���F souryo6 TOWN OF SOUTHOLD BUILDING DEPT. �yCOU631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/C LKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFET NSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMA KS: 0MA100 l lV DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) -------------------------------------- FOUNDATION --------------------- - --=FOUNDATION(2ND) kA tai T ROUGH FRAMING PLUMBING ' rb INSULATION.PER N.Y. y STATE ENERGY CODE �1 tiL � JA/ V I FINAL ADDTTIONAL COMME. TS 06) 1401 s Lb`0 • C CL-e,e, " � H =O�S�fFOIK�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y x Town Hall Annex 54375 Main Road P. O. Box 117.9 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtownny.gov f Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ' PERMIT NO. Building Inspector: SEP 2 4 2021 BUILUINU.. Applications and forms must be filled out in their-entirety.Incomplete TOWN OF SOUTHOLD applications,will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:September 2021 OWNER(S)OF PROPERTY: Name:David Pugh------- -- - ------ -- - ------ SCTM#1000_15_-4-9 l _-- - -----------_ �. Project Address:545 Rvder Farm Lane, Orient, NY 11.957 Phone#:917-601-1528E mail:davidpugh71 @gmail.com Mailing Address_345 E. 81 St Street, Apt_ 10L, NY,_NY 10028 CONTACT PERSON: Name:Martin D. Finnegan, Esg; _ Mailing Address:Post Office Box 9398,_33W. 2nd Street, Riverhead, NY 11901 Phone#:631-727-2180 x265 Email:mfinnegan@su_ffolklaw.com DESIGN PROFESSIONAL INFORMATION: Name:Richard Massa Mailing Address:90 8th Avenue, Brooklyn,_NY_11215 Phone#:212-367-8992 Email:richard@rma-nyc.com _.._. _-a..__-_..___-_ CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration []Repair ❑Demolition Estimated Cost of Project: El Other Interior Alterations $ Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_400 this property? ❑Yes ®No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone. Ordinance of the Town'of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, Musing code and regulations and to admit`authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class'A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): David Pugh ❑Authorized Agent BOwner Signature of Applican . Date. 1 STATE OF NEW YORK) SS ) COUNTY OF yu David Pugh being duly sworn,deposes and says that(s)pis the applicant (Name of individual signing contract) above named, (S&i5 the Owner (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best o&is her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this SAMUEL JOSEPH GARCIA NOTARY PUBLIC STATE OF NEW YO Registration No.01GA6382579 �� Qualified in Kings County J day of September 20 CQ, Exp October 29, otary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 C ik I ING DEPARTMENT- Electrical Inspector `� f TOWN OF SOUTHOLD AN H x J 2 6 VoGvn a Annex- 54375 Main Road - PO Box 1179 o • BUILDING oG_;,is Southold, New York 11971-0959 TOWN OFSOlJ-r D e ephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cilsoutholdtownny.gov - seand(aD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: I 0;2D Company Name: ` Electrician's Name: Q S License No.:MLS Ca 1 3 1 Ele email: Elec. Phone No: I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: --�`� tw Address: g (� Cross Street: I Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUQE SQUARE FOOTAGE (Please Print Clearly): -- Square Footage: j,5o Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New service[-]Fire Reconnect[-]Flood Reconnect[-]Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION Q� �OSUFfOL�`,O� it I� �;1 i3l, I ING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD H� JAN 2 6 V&n nnex - 54375 Main Road - PO Box 1179 • Bu1LD11\;t d>r -1: Southold, New York 11971-0959 TOWN OF scu ` °eephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a)southoldtownny.gov � seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) _ Date: (—Ob0; Company Name: may` jC, c, Electrician's Name: '" Qr\ Q S License No.: Ca 1 .3 1 _Eleemail: Elec. Phone No: _ 36 — 1 request an email copy of Certificate of Compliance Elec. Address.: Q JOB SITE INFORMATION (All Information Required) Name: Address: 51 Cross Street: Phone No.: oft6 oL Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION ppOFWORK, INCLUQE SQUARE FOOTAGE (Please Print Clearly): 4fArr-S Square Footage: ] v Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In El Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) r Service Size❑1 PhF-13 Ph_ Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's f (y{! I UC Lts Fans F"ridge Exhaust Oven „ WD' , Smok�s DW Mini: _ �: .. . ...: ... .. :.._....., ..............._.:_...._ ...Mier..._ _ . ..... _. _ ..... __. _. Carbon. .. - o . . :..:`Generator.: b- .,. . .. _... Cook _. op sf f Tcan er Com AC AH Hood {Servi A Have . r ce mps, Used Special:. Comments: N Lor 64 SURVEY OF PROPERTY AT ORIENT POINT Pin 8s s'oo"E 150.00' TOWN OF SOUTHOLD REAR REB. SUFFOLK COUNTY N FEN.COR. POST &WNYL MESH DEER FEN. FEN.COP- 0 3'N o/v O.s'S I FND. s' METAL o x r 1000-15-04-09 Y GATE x m Q SCALE.• 1=30' O I I h u2TALI ► o' JUNE 22, 2011 � �, 0 x DECEMBER 17, 2019 (ROAD ABANDO M NMENT Z Oy�` PROPANE m d L+1 TANK I Z {1 I \ O C- % 24.0`OU7Dy SHO Wff.' 4 p ASPHALT WOOD, v b MIR 88COUNTER94 UNDER ARBOR STEPS �.6'y 4 OARBOR OVER DECK tECK r*f ~ $ CERTIF/ED T0: DAVID PUGH AND TINA SILVESTRI v FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC STEPS WOOD 27Y po W0011 cnMETALJ ELEVATIONS REFERENCED TO NAND W LOT 62 KEY AREA=25,829 St? FT. v Q = REBAR n ��///��,�� WI R D. EC� C� � °� E ® = WELL W A = STAKE x REBAR FN = LEST HOLE -• ED j54,42'� -Sl*341001E SEP 2 4 2021 cc - PIPE7 97 BUILDING DEPT. �5 ' '?�• ~ ' 42 `� S2 ' 4- w 7�800"E TOWN OF SOUTHOLD ■ - MONUMENT 17.64' = WETLAND FLAG SI4.414p'W �oE0L t'd'L NEW �,NE , , oN � = UTTUTY POLE N�4.41'''� PARI 0 6E A�ANDSQ�FT l \-1-62.25 / = ROAD CENTERLINE FEN.COR. 'f0 ,3 ➢28 � N 2 O.WE AR E57= DEER FENCE �w OWN �' pF �EbV -- off —= OVERHEAD WIRES c o / oN �� y s �4140�W P�CNO? LOT NUMBERS REFER TO 's/AP OF ORIENT BY 7HE FLED IN THE SUFFOLK COUNTY CLERKS OFFICE ON OC1bBE1r 1961 AS FILE NO. .3444 ,r O ANY AL7ERA170N OR ADD/AON To 7H/S SURVEY/S A NOLA17M OF / SEC770N 7209 OF 7HE NEW YORK STATE®UCA77AN LAW. AS PER SECTIOE7YCEPpT N.Y.S UC. NO. 49618 N 7209—SUBDINS/ON 2 ALL CER1/f1CA110NS A►E74EON ORS, ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY/F SAID MAP P.C. OR COP/ES BEAR 7HE IMPRESSED SEAL OF 7HE SURVEYOR JWOSE 020 FAX (631) 765-1797 S/GNA LURE APPEARS HEREON. P.O. Box 909 SOUTHOLD, N.Y. 1 971 SMEET 11—168 \L Az4crn LL_ 0 0 O 'PROVED AS NOTED la1 J.P.# ' 25.74' 190.53' BUILDING DEPARTMENT AT 25.74' 190.53 ® .02 8 AM TO 4 PM FOR THE - ® 75 11V S: rOUNDATION - TW REQUIRED FOR POURED CON RETE EXISTING EXISTING2. ROUGH - FRAMING '& PLUMBING ' ' SHED FREESTANDING —FREES TANDING SHED 3. INSULATNON 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION HALL MEET THE REQUIREMENTS OFT E CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTR CTION (ERRORS. ri $.., �,�e �a..d..,-, J,t Ji°..��id E YL�` {(''2�� � I�Dr r �r p1 ch- 11Vcu'7 i " IXIS nNO . i/ EXISTING 'I --v N 1 U R 1'C Z G m STATE & TOWN CODES RED DECK ARBOR RED DECK VAS hLOUiRL OF- OJ oO CIONS OF EXISTING EXISTINGOUTDOO OUTDOOR SHOWER P SOUTHOI TOWN ZBIA Lu =o � SHOWER R =) r^ V' J SOUTHOL TOWN PLANNING BOARD U o U o I-T FZ SOUTHOL TOWN TRIUSTEES o X (� I �J.`r'.S,DEC r_. x m I o x EXI9ING EXISTING 2 STOREY F AME HOUSE 7 STOREY FRAME GARAGE -I'ING EXISTING r� X , 2 STOREY F AME HOUSE �STOREY FRAME GARAGE N X o Cl D ARc IXIS ING I 48'6*. . , LANDING , ..... .. ..• ::::: , \� D 1 ,' AND TEPS •• , ':.FRP..• EW':.�:. i I .:?::.FRG Etrrctr.:•:::.. I EXISTING PLUMBER CERTIFICA VON • WALKWAY I -- ON LEAD CONTENT BE ORE LINE OF PROPOSED CERTIFICATE OF OCCUPANCY •• I EXISTING f + Q OVERHANG 9� 7 V O EXSOLDER USED IN WATER F0F 3076 (�E-`i`� ASPHALT ASPHALTNEWA DRIVEWAY DRIVEWAY V, 6 PROPOSED NEW SUPPLY SYSTEM CAMI JOT WALKWAY EXCEED 2/10 OF 1% LEAD. • _ _ _ _ _ _ _ �— _ _ _ / PROPERTY LINE _ - -----PROPE LINE /n \ / 153.85' / 153.85' 0 F- RYDER FARM LANE4 RYDER FARM LANE a W 0 EXISTING SITE PLAN PROPOSED SITE PLAN U- z O SCALE: 1/16" = 1'-0" N SCALE: 1/16" = 1'-0" °� W W w zce_ z 2: O W a z LL � ,_•, W W N P-4 V) W Z N U) Z oz � ZONING ANALYSIS FOR 545 RYDER FARM LANE CONT. Lu >i (5 FW- LLn O rn a U) m SCOPE OF WORK: PROPOSED ADDITION TO SINGLE FAMILY HOME IN EXISTING NON-COMPLIANT MINIMUM SIDE YARD: 15' Oi— U z m FRONT YARD SETBACK. VARIANCE REQUIRED. EXISTING SIDE YARDS: 48.5' [COMPLIES] '' Q LU �' Z 56.1' [COMPLIES] Q 0 ADDRESS: 545 RYDER FARM LANE,ORIENT POINT, NY MINIMUM COMBINED SIDE 0 0 Q AHJ: TOWN OF SOUTHOLD YARDS: 35' SCC ZONING TEXT: TOWN OF SOUTHOLD TOWN CODE CHAPTER 280 EXISTING COMBINED SIDE J O TAX MAP ID: 1000-15.4-9 YARDS: 104.6' [COMPLIES] LOT AREA: 0.59 ACRES/25,700 SF MINIMUM REAR YARD: 50' ZONE: R-40 EXISTING REAR YARD: 87.42' [COMPLIES] Z MINIMUM LIVABLE FLOOR AREA: 850 SF W USE REGULATIONS EXISTING LIVABLE FLOOR Lu §280-17 USE PERMITTED: ONE-FAMILY DETACHED DWELLING AREA: 1,982 SF [COMPLIES] USE PROPOSED: ONE-FAMILY DETACHED DWELLING[COMPLIES] PROPOSED LIVABLE FLOOR AREA: 2,104 SF [COMPLIES] MAXIMUM LOT COVERAGE: 20D/o ct BULK REGULATIONS EXISTING LOT COVERAGE: 3.9%D (991 SF/25,700 SF) [COMPLIES] F- PROPOSED LOT COVERAGE:4.3%D (1113 SF/25,700 SF) [COMPLIES] Z Ln DENSITY AND MINIMUM LOT SIZE MAXIMUM HEIGHT: 35'/2 Yz STORIES §280-18 MINIMUM LOT SIZE: 40,000 SF EXISTING HEIGHT: 25'/2'/STORIES [COMPLIES] °d a 280 ATT 1 EXISTING LOT SIZE: 25,700 SF [EXISTING NON-COMPLIANT] D U E v LC, , w N 00N 280 ATT 3 MINIMUM LOT WIDTH: 150' PARKING REGULATIONS V Z Z 00 00 00 EXISTING LOT WIDTH: 153.85' [COMPLIES] §280-78 MINIMUM REQUIRED PARKING OCT 0 8 2021 F W ` MINIMUM LOT DEPTH: 175 SPACES: 2 ,._, � W w2aooCID EXISTING LOT DEPTH: 150' [EXISTING NON-COMPLIANT] EXISTING PARKING SPACES: 2 [COMPLIES] BUILDING DEPT. V ,-i O M M TOWN OF SOUTHOLD H z:MINIMUM FRONT YARD: 50' _ R i.- Lu >- N N EXISTING FRONT YARD: 35.8' [EXISTING NON-COMPLIANT] V a H N N PROPOSED FRONT YARD: 26.83' [NON-COMPLIANT] ccrftcl� 2: p =) W ---VARIANCE REQUIRED--- a DC O� V) Z a- LL DESIGN REVIEW . rn O O O N REMOVE SECTION OF WALL REMOVE SECTION OF NALL TO ACCOMMODATE TO ACCOMMODATE RE LOCATED RELOCATED WINDOW SLIDING GLASS DOOR — — — — — —— — I (Z I I KITCHEN ' REMOVE EXISTING I I REMOVE EXISTING / I KITCHEN CABINETS I I CLOSET WALLS — —I AND ALL BASES. L — — J — Li T � - � I I I \ J REMOVE EXISTING WOOD STEPS z o --1 U) o0 o U-10 o � � L � z O � U o X i� X O X c4 X X ED A/? Ncp IN\ 9j. ?3076 O FOS NE�� l REMOVE EXISTING __ _ _ _ _ _ - - CONCRETE LANDING L- --- - - - - - J AND STEPS DEMO PLAN 1ST FLOOR DEMO PLAN 2ND FLOOR N z SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" N4 F.-I O F_ 0 w O LI) LLz Z g O a p O Lu w O DEMOLITION NOTES ASBESTOS ABATEMENT NOTES (IF REQ'D) LEAD PAINT NOTES (IF REQUIRED) z z 2: 0 w N 1. REMOVE ONLY WALL SECTION INDICATED OF NON ASBESTOS. ALL CONTRACTORS SHALL USE SAFE WORK PRACTICES DURING THE 0� >- LOAD-BEARING WALL AS SHOWN ON PLANS IN THE EVENT THAT ASBESTOS CONTAINING MATERIAL (`ACM") IS WORK AND TAKE PRECAUTIONS TO PREVENT THE SPREAD OF DUST AND Q W z DISCOVERED BY THE LESSEE, ITS CONTRACTORS, AGENTS OR DEBRIS WHICH MAY CONTAIN LEAD. 13-10" w W N Q 2. REMOVE AFFECTED BASEBOARD ON EACH SIDE OF WALL. EMPLOYEES, THE OWNER SHALL COMPLY WITH THE REQUIREMENTS W Z O OF LOCAL LAWS, AS AMENDED, BY FILING WITH THE APPROPRIATE [A] SUCH PRACTICES SHALL INCLUDE BUT ARE NOT LIMITEDTO (1) TIE INTO EXIST. N wLr)3. REMOVE FINISHES AND FIXTURES AS REQUIRED. ASBESTOS EVALUATION FORMS AS COMPLETED BY A CERTIFIED LIMITING ACCESS TO THE WORK AREA TO ONLY WORKERS,(2)COVERING FOUNDATION WALL z oC 1.0 ASBESTOS INVESTIGATOR. COPIES OF THE ASBESTOS THE WORK AREAD WITH SIX MIL POLYETHYLENE PLASTIC ORw = O 4. PROTECT ALL SURFACES WHICH ARE TO REMAIN. INVESTIGATOR'S NEW JERSEY CERTIFICATION AND THE EVALUATION EQUIVALENT, (3)PROTECTING THE WORKERS,(4) PROTECTING LESSEE'S AT 12" OC - oC = j w m FORMS FILED WITH THE LOCAL BUILDING AUTHORITIES. BELONGINGS BY COVERING OR REMOVING THEM FROM THE WORK AREA, Ln O p pp 5. PROTECT ADJACENT FLOOR AND WALL SURFACES. IN THE EVENT ACM WILL BE DISTURBED BY THE WORK, THE (5)WETTING THE PAINTED SURFACES BEFORE DISTURBING THE PAINT - - - - - - OWNER'S CONTRACTOR SHALL, AS REQUIRED BY LAW, EMPLOY ONLY AND(6)WETTING THE DEBRIS BEFORE SWEEPING. CONTRACTORS 6. CONTRACTOR SHALL ASSURE THAT NO BUILDING LICENSED AND CERTIFIED ASBESTOS REMOVAL AND DISPOSAL AND/OR WORKERS MAY NOT USE UNSAFE PAINT REMOVAL PRACTICES, O Q W Z SYSTEMS WILL BE DEMOLISHED OR DAMAGED DURING COMPANIES AND HANDLERS. EVIDENCE OF LICENSING AND INCLUDING (1) OPEN FLAME BURNING, (2) POWER SANDING OR Q n Z THE REMOVAL OF THE WALL SECTIONS INCLUDING CERTIFICATION OF ASBESTOS CONTRACTORS SHALL BE SUBMITTED SANDBLASTING(UNLESS A SPECIAL VACUUM ATTACHMENT IS USED TO Q BUT NOT LIMITED TO VENTILATION,AND FIRE RATED TO THE OWNER PRIOR TO THE COMMENCEMENT OF THE WORK. CONTAIN DUST),AND (3) DRY SCRAPING MORE THAN A DE.MINIMUS NEW PC FOOTINGu 62 SHAFTS, ELECTRICAL, GAS, HEATING, PLUMBING ALL OF THE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE SURFACE AREA(DE MINIMUS MEANS AN AREA OF LESS THAN ONE _ RISERS, ETC. WITH ALL APPLICABLE LEGAL REQUIREMENTS APPLICABLE TO THE SQUARE FOOT PER ROOM). NEW REINFORCED 10" PC _j REMOVAL, ENCAPSULATION AND DISPOSAL OF ACM AS REQUIRED FOUNDATION WALLS. 7. REMOVE EXISTING SUPPLY AND RETURN AC GRILLS AND OR REQUESTED BY THE NEW JERSEY DEPARTMENT OF [B] NO MORE THAN SIXTY(60) DAYS PRIOR TO BEGINNING RENOVATION °O � Z RE-INSTALL NEW AS NECESSARY TO COORDINATE WITH ENVIRONMENTAL PROTECTION AND ANY OTHER GOVERNMENTAL ACTIVITIES IN THE HOME THE CONTRACTOR SHALL PROVIDE THE OWNER ;; SEE STRUCTURAL NEW PROPOSED LAYOUT. AGENCIES HAVING JURISDICTION. WITH THE ENVIRONMENTAL PROTECTION AGENCY(THE-EPA-)PAMPHLET DRAWINGS FOR DETAIL. '-' ENTITLED, PROTECTING YOUR FAMILY FROM LEAD IN THE HOME, (THE U) 8. CONTRACTOR(S) SHALL ASSURE THAT NO BUILDING SYSTEMS "PAMPHLET"). THE CONTRACTOR SHALL BE RESPONSIBLE FOR w WILL BE DEMOLISHED OR DAMAGED DURING DEMOLITION, OBTAINING THE OWNER'S WRITTEN ACKNOWLEDGEMENT OF RECEIPT OF =` "• ;': .?'""• * : s INCLUDING BUT NOT LIMITED TO VENTILATION AND FIRE RATED THE PAMPHLET OR A CERTIFICATE OF MAILING EVIDENCING SAME. PAINT SHAFTS, ELECTRICAL, GAS, HEATING, PLUMBING RISERS OR IMPREGNATED CLOTH-TYPE COVERS SHOULD NOT BE USED AS A INTERCOM. COVERING OR BARRIER OR IN ANY OTHER WAY BY ANY CONTRACTOR IN CONNECTION WITH THE ALTERATIONS,AS SUCH ARE POTENTIAL6' ,,f a-• I- 9. CONTRACTORS)SHALL MAKE ADEQUATE PROBES OF ALL EXISTING SOURCES OF LEAD DUST. CONTRACTOR TO CLEAN THE ALTERATION Ln Z Ln PARTITIONS TO BE DEMOLISHED TO DETERMINE THE PRESENCE OF SITE,PROPERLY REMOVING ALL DUST AND DEBRIS. CONTRACTORS TO in ANY CONCEALED RISERS, ELECTRIC CONDUIT,TELEPHONE, USE A HIGH EFFICIENCY PARTICULATE AIR VACUUM (NEPA) FOR ALL ,� 4 °6 a INTERCOM OR ANY OTHER UTILITY LINES SERVICING THE BUILDING CLEAN-UP ACTIVITIES. NO CHILDREN SHALL HAVE ACCESS TO THE J v(*-' "j . w N N PRIOR TO COMMENCING DEMOLITION. ALTERATION SITE OR DUSTY AREAS THAT MAY POSSESS LEAD HAZARDS. v {. �. .• w w Z 0a0 0000 10. REMOVE ALL EXISTING BATH FIXTURES AND FINISHES AS SHOWN [C] THE REQUIRING'THE USE OF LEAD-SAFE PRACTICES"FOR WORK Lu w Y FOR FIRST LEVEL BATHROOM. IMPACTING 6 SQ. FT.OR MORE OF LEAD PAINT IN BUILDWGS ERECTED w = Q O a! ID �o BEFORE 1978,AND ALL APPLICABLE STATE AND LOCAL REGULATIONS Emma E- U .-i 0 PROPOSED WORK MUST COMPLY WITH FEDERAL EPA RULE ISSUE APRIL = R F=- w >- N 22,2008. Q� 2: O -,n w N N Q oC m (n Z a. li LEGEND NEW FOUNDATION PLAN EXISTING TO REMAIN — — —— —— SCALE: 1/4" = 1'-0" N • — — —— — — EXISTING TO BE DEMOLISHED DESIGN R rn C) 0 O M PROVIDE FOR DIRECT VENT NEW SLIDING GLASS DOOR NEW SLIDING GLASS DOOR TO EXTERIOR FOR IN EXISTING LOCATION NEW WINDOW IN NEW OPENING ELECTRIC DRYER. DBL.2x10 LVL BEAM IN NEW OPENING DBL. 2x10 LVL BEAM 4x4 POST 4x4 POST 4x4 POST 4x4 POST - J L - - NEW RANGE r IN EXISTING NEW DISH WASHER NEW ICE MAKER ', LOCATION IN NEW LOCATION PROVIDE ACCESS DOOR FOR EXISTING CONNECTION TO NEW A WORK IN NEW LOCATION I I BATHROOM NEW SINK LAUNDRY EQUIPMENT NEW SINK IN EXISTING LOCATION 3'-10�" NEW STACKED O 2 ELECTRIC WASHER NEW REF/FREEZER WITH ICE MAKER IN ( I EXISTING AND DRYER EXISTING LOCATION NEW KITCHEN ISLAND I I BEDROOM i NEW BENCH CO NO WORK SEAT 2'-10" NEW WINE FRIDGE NEW IN NEW LOCATION �-1N ( 1 KITCHEN o LAUNDRY CL. - II 20-2 Lo co EXISITING - - - - -- - - - - - - NEW WOODEN LIVINGROOM O LANDING AND STEP EXISTING 1 STAIRS 3-0 102 10" o 0 0 NO WORK E- O °C = OO 1O � O � EXISITING EXISTING o Z) in GARAGE LU MASTER BEDROOM = o NO WORK L o V) o EXISTING a DINING ROOM NO WORK EXISTING EXISTING o x BEDROOM BEDROOM o x NO WORK NO WORK N x Li DBL.2x101 I VL BEAM �GRED�C 4x4 POST 1 4 .� x4 POST ��� GD 4x4 POST I = 4x4 POST 1 �� CL CL 101A 1101B R co '� � � ?3076 y0 o V NEW I = L7 NE VESTIBULE U-) �� 60 4x4 OST I I I I 101 �� I I - 4x4 POST I 12-0f II t o I II I I II I 4x4 POST I 4x4 POST PROPOSED PLAN 2ND FLOOR -1 I I I III III I o LU - -- - - - fll SCALE: i/4" = V-0" a o � Ln W z N Q O d. DBL.2x10 LVL BEAM DBL.2x10 LVL BEAM F- � A ° o GENERAL CONSTRUCTION NOTES U- LL_ 13'-10" 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RULES 16. CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT THE 31. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING 43. THE GENERAL CONTRACTOR/OR ENGINEER SHALL SUBMIT ALL W W z AND REGULATIONS OF THE NEW JERSEY BUILDING CODE AND ALL ARCHITECT FOR ANY CLARIFICATION OF DRAWINGS OR FINISHED SURFACES TO INCLUDE CORNER BEADS, STOPS, ETC. FABRICATION SHOP DRAWINGS AND FIXTURE CUTS TO THE z z N OTHER LOCAL,STATE AND FEDERAL CODES HAVING JURISDICTION INFORMATION NEEDED,2 WEEKS PRIOR TO CONSTRUCTION OR FOR CHIPS,CRACKS, HOLES, DAMAGED SURFACES AND ANY ARCHITECT FOR APPROVAL. ALL SHOP DRAWINGS AND CUTS SIGNED J Y 1 0 WHETHER OR NOT SPECIFIED ON THE DRAWINGS. ORDERING MATERIALS OF THE SAME. OTHER DEFECTS CAUSING AN APPEARANCE DIFFERENT FROM A "APPROVED"SHALL SUPERSEDE ORIGINATING DRAWINGS IN DESIGNz 2. THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS 17. BEFORE SUBMITTING A PROPOSAL,ALL CONTRACTORS SHALL NEW FIRST CLASS FINISHED INSTALLATION. THESE DEFECTIVE APPEARANCE ONLY,ALL CONTRACTORS SHALL ASSUME 2: O V Q (INCLUDING PLUMBERS AND ELECTRICIANS)SHALL BE LICENSED TO VISIT THE SITE, FAMILIARIZE THEMSELVES WITH EXISTING SURFACES SHALL BE REPAIRED OR IF BEYOND REPAIRING,THEN RESPONSIBILITY FOR ALL ERRORS IN THEIR DRAWINGS. } PERFORM WORK IN THE LOCAL JURISDICTION AND THE STATE OF CONDITIONS,AND SATISFY THEMSELVES TO THE NATURE AND THE GENERAL CONTRACTOR SHALL REMOVE EXISTING AND 44. GENERAL CONTRACTORS NOTE: ALL EQUIPMENT FURNISHED BY W V) PROPOSED PLAN ST FLOOR NEW JERSEY. SCOPE OF THE WORK AND THE DIFFICULTIES THAT REQUIRE ITS INSTALL NEW SURFACES. OWNER[F.B.O.]AS INDICATED AND/OR DIRECTED,THE CONTRACTOR W N 3. CONSTRUCTION SHALL COMPLY WITH ALL FEDERAL,STATE AND EXECUTION. 32. ALL EXISTING ITEMS NOT BEING REMOVED SHALL BE SHALL RECEIVE SIDEWALK LEVEL', CONVEY THE EQUIPMENT AS 10� z O LOCAL CODES,ORDINANCES,RULES AND REGULATIONS 18. THE SUBMISSION OF A PROPOSAL SHALL BE AN INDICATION THAT REFURBISHED WHERE REQUIRED.ANY LOOSE ITEMS SHALL BE REQUIRED, MECHANICAL,AND ELECTRICAL CONNECTIONS COMPLETE W N W W PERTAINING TO LABOR AND MATERIALS. THE CONTRACTOR HAS VISITED THE SITE AND LATER CLAIMS, TIGHTENED(CEILING EXIT SIGN, ETC.)AND ANY MISSING PARTS AND READY FOR USE. 0 IY (n �� �� N4. ALL CONTRACTORS SHALL OBSERVE ALL LAWS AND ORDINANCES LABOR, EQUIPMENT,OR MATERIAL REQUIRED OR FOR OF ANY ITEMS TO REMAIN SHALL BE REPLACED (LIGHT FIXTURE, 45. ALL EXITS SHALL BE KEPT READILY ACCESSIBLE AND UNOBSTRUCTED } l0 SCALE: 1/4 = 1 -0 GOVERNING THE WORK OF THE CONTRACT,AND SHALL OBTAIN, DIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN ETC.) BY THE GENERAL CONTRACTOR TO ACHIEVE A FINISHED AT ALL TIMES. � W 2 a- AND PAY FOR ANY ADDITIONAL PERMITS,INSPECTIONS OR FEES FORESEEN HAD AN EXAMINATION OF THE SITE BEEN MADE,WILL FIRST CLASS INSTALLATION APPEARANCE. 46. EXIT DOORS SHALL BE READILY OPENABLE AT ALL TIMES FROM THE Ln J (D O REQUIRED FOR THE WORK OF HIS TRADE OR TRADES,BEFORE NOT BE RECOGNIZED. 33. ALL EXISTING MATERIALS TO BE REMOVED AND REINSTALLED BY SIDE FROM WHICH EGRESS IS TO BE MADE. d' 13� m WORK IS TO BE STARTED. 19. ALL WORK SCHEDULES SHALL BE REVIEWED WITH THE OWNER THE GENERAL CONTRACTOR SHALL BE PROTECTED BY THE 47. NO CONDUITS, PIPES, ETC.,SHALL ENCROACH UPON FIRE RATED In O d a m 5. ALL WORK SHALL BE PERFORMED BY INSURED CONTRACTOR(S). AND NO WORK SHALL COMMENCE UNTIL WRITTEN APPROVAL OF GENERAL CONTRACTOR AND IF DAMAGED SHALL BE REPLACED PARTITIONS ENCLOSING GARAGE, MECHANICAL ROOMS, STAIRS, OR z6i . � ��' THE CONTRACTOR(S)SHALL OBTAIN AND DISPLAY CERTIFICATES THE SCHEDULE IS OBTAINED FROM THE OWNER. THE GENERAL AT HIS EXPENSE. VENTS. OF WORKMAN'S COMPENSATION AND LIABILITY. CONTRACTOR SHALL OBTAIN APPROVALS OF ALL WORK 34. ALL DAMAGED SURFACES (FINISHED FLOOR, WALL, ETC.) SHALL 48. PROVIDE AND/OR INSTALL ANCHORS,INSERTS, HANGERS, ETC_AS O ~ U Z 6. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS TO SCHEDULES. BE REPAIRED TO THE SATISFACTION OF THE ARCHITECT. REQUIRED FOR VARIOUS TRADES. Q Lu COMPLETE THE WORK-OWNER IS RESPONSIBLE FOR PAYING 20. ALL WORK SHALL BE CARRIED FORWARD IN A WORKMAN-LIKE 35. IN ADDITION TO BEING AMPLY PROTECTED THROUGHOUT THE 49. THE GENERAL CONTRACTOR'S CEILING CONTRACTOR SHALL CLOSELY 0 n PERMIT FEES. MANNER,AND UNLESS OTHERWISE NOTED, SHALL MEET ALL THE PERIOD OF CONSTRUCTION ALL"EXISTING TO REMAIN", COORDINATE HIS WORK WITH THAT OF THE PLUMBING AND Q 0 7. THE GENERAL CONTRACTOR SHALL PROTECT ALL SURFACES IN REQUIREMENTS THAT WILL EFFECT THEIR WORK. EXISTING RELOCATED OR NEW ITEMS, INSTALLED BY THE ELECTRICAL CONTRACTORS WHEREVER THEIR RESPECTIVE WORK IS U aC AREAS OF THE BUILDING NOT AFFECTED BY THE PROPOSED21. PROVIDE ALL EQUIPMENT AND TEMPORARY CONSTRUCTION GENERAL CONTRACTOR SHALL BE THOROUGHLY CLEANED TO THE CONTIGUOUS. O Q Q CONSTRUCTION. NECESSARY TO SAFEGUARD ALL PERSONS AND PROPERTY. SATISFACTION OF THE ARCHITECT JUST PRIOR TO BEING 50. PRIOR TO CLOSING UP ANY CEILING,ALL PLENUM SYSTEMS (PLUMBING _I WINDOWS: LEGEND 8. EACH CONTRACTOR WILL BE HELD STRICTLY RESPONSIBLE FOR HIS 22. PERSONS SUPERINTENDING WORK SHALL INSPECT ALL DEVICES TURNED OVER TO THE OWNER. AND ELECTRIC) SHALL BE INSPECTED AND WHERE REQUIRED TESTED WORK. ANY DISCREPANCIES IN THE PLANS OR DETAILS AND FIELD FOR ADEQUATE SAFETY. 36. THE GENERAL CONTRACTOR SHALL THOROUGHLY CLEAN ALL BY CONTRACTORS, ENGINEERS,AND BY THE AUTHORITIES HAVING 1. WOOD WINDOWS AND EXTERIOR WOOD DOORS TO BE BY ANDERSON, CONDITIONS SHALL BE CALLED TO THE ATTENTION OF THE 23. PROVIDE FIRE FIGHTING EQUIPMENT AS REQUIRED BY FIRE LIGHT FIXTURES AND FIXTURE LENSES,A/C DIFFUSERS AND JURISDICTION TO INSURE THEIR PROPER INSTALLATION AND z ARCHITECT BEFORE COMMENCING ANY WORK. DEPARTMENT. REGISTERS, DECORATIVE FINISHES,ALL DOORS, ETC. PRIOR TO FUNCTION. IN THE SIZE AND MODEL NUMBER SHOWN ON THE DRAWINGS. NEW POURED CONCRETE WALL g, DIMENSIONS SHALL NOT BE SCALED.ALL DIMENSIONS SHALL BE AS 24. THE GENERAL CONTRACTOR IS RESPONSIBLE TO EXERCISE STRICT LEAVING THE JOB. 51. THE GENERAL CONTRACTOR SHALL PROVIDE CUT OUTS AND OTHER PROVIDE INSECT SCREENS, SEE WINDOW SCHEDULE FOR DETAILS. WRITTEN ON DRAWINGS AND VERIFIED. CONTROLS OVER THE JOB SITE IN ORDER TO PREVENT ANY DIRT 37. ALL MATERIALS AND CONSTRUCTION SHALL BE IN STRICT SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR U) 2. ALL GLAZING IN DOORS AND WINDOWS TO BE INSULATED, HIGH NEW 4%"' WALL PARTITION WITH " 10. THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE OR DUST FROM LEAVING THE WORK AREA. ACCORDANCE WITH THE LATEST EDITION OF THE ASTM LIGHTING FIXTURES,AND OTHER INSERTED ITEMS. W PERFORMANCE LOW E COATING,AND TEMPERED. METAL STUDS AND %" CEMENTITIOUS FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND 25. THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE SPECIFICATIONS APPLICABLE,AND SHALL CONFORM TO THE 52. CHANNELING OR DEMOLITION OF ANY STRUCTURAL ELEMENTS WILL 3. SECURE WINDOW AND DOOR UNITS PER MANUFACTURERS BOARD TYPE 'X' ON EACH SIDE. ARCHITECT'S OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM BUILDING AND ANY ADJOINING PROPERTY OR WORK,AND STANDARDS AND RECOMMENDATIONS OF THE VARIOUS TRADE NOT BE ALLOWED. ci� REQUIREMENTS. TYPE-1 THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS., DAMAGE TO SAME CAUSED BY HIS WORK OR WORKMEN MUST BE INSTITUTIONS (A.C.I.,A.I.S.C., ETC.) WHERE APPLICABLE. ALL 53. INSTALL ALL NEW WALLS AND CEILINGS AS SHOWN ON DRAWINGS. O 11. ALL CONSTRUCTION,DIMENSIONS AND DETAILS SHALL CONCUR MADE GOOD WITHOUT DELAY. PATCHING AND REPLACING OF MATERIALS INCORPORATED INTO THE WORK SHALL BE NEW. 54. ALL WALLS AND CEILINGS ARE TO BE TAPED SPACKLED, 4. EXTERIOR FINISH TO BE WHITE, INTERIOR FINISH TO BE DETERMINED NEW 2" THICK WALL FURRED OUT WITH AND BE DETERMINED FROM THESE DRAWINGS ONLY. DAMAGED WORK SHALL BE DONE BY THE CONTRACTOR WHO IS 38. ALL MATERIALS,ASSEMBLIES, FORMS,AND METHODS OF SKIM COATED, PRIMED AND FINISHED SMOOTH. W FROM CONCRETE FOUNDATION WALL. 12. WHERE THE CONTRACT,NOTES OR DRAWINGS CALL FOR ANY RESPONSIBLE FOR THE DAMAGE. CONSTRUCTION AND SERVICE EQUIPMENT SHALL MEET THE CONTRACTOR IS TO PAINT WITH A SINGLE COAT OF %" FURRING METAL HAT CHANNEL WORK OF A MORE STRINGENT NATURE THAN THAT REQUIRED BY 26. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY REQUIREMENTS OF THE LOCAL&STATE BUILDING CODE AND PRIMER AND TWO FINISH COATS. PAINT TO BE 4>_ WITH X" THICK CEMENTITIOUS BOARD THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING PROTECTION OF HIS WORK UNTIL TURNED OVER TO THE CLIENT. SHALL HAVE BEEN ACCEPTED FOR USE UNDER THE PRESCRIBED MANUFACTURED BY BENJAMIN MOORE OR AN APPROVED EQUAL. H r-1 TYPE 'X'. TYPE-2 JURISDICTION OVER THE WORK,THE WORK OF THE MORE 27. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING, CODE TEST METHODS. COLOR TO BE SELECTED BY ARCHITECT. od u rN-I STRINGENT NATURE CALLED FOR THE CONTRACT,CONSTRUCTION AND PATCHING OF WORK THAT MAY BE REQUIRED TO MAKE ALL 39. ALL MATERIALS,ASSEMBLIES AND METHODS OF CONSTRUCTION 55. CONTRACTOR TO INSTALL ALL NEW DOORS, CASINGS, J CLNOTES OR DRAWINGS SHALL BE FURNISHED IN ALL CASES. PARTS COME TOGETHER PROPERLY AND FIT TO RECEIVE OR BE REGULATED BY THE N.Y.C. BUILDING CODE SHALL BE SUBJECT BASE MOULDING, HARDWARE, ETC.THROUGHOUT HOUSE. W *-1 N N ROOM NUMBER 13. ALL DRAWINGS AND CORRESPONDING NOTES ARE BINDING AND RECEIVED BY WORK OF OTHER CONTRACTORS SHOWN UPON OR TO CONTROLLED INSPECTION BY THE PERSON SUPERINTENDING 56. CONTRACTOR TO INSTALL AND PAINT ALL NEW MOULDINGS AND TRIM. M 00 TILES: tot WILL BE PART OF THE CONTRACT DOCUMENTS. REASONABLY IMPLIED BY THE DRAWINGS AND NOTES. THE CONSTRUCTION. SIGNED COPIES OF ALL TEST AND 57. ALL MATERIAL INSTALLED IN CRAWL SPACE TO BE OFz z 1 DOOR NUMBER 14. ALL WORK LISTED ON THE CONSTRUCTION DRAWINGS SHALL BE 00 00 28. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUTOUTS INSPECTION REPORTS SHALL BE FILED THROUGH THE WATERPROOF OR AT MINIMUM,WATER RESISTANT CALIBER. f- fW" W SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR UNLESS AND PATCHING REQUIRED FOR THE INSTALLATION OF ALL WORK. ARCHITECT WITH THE LOCAL AUTHORITY HAVING JURISDICTION. 58. CONTRACTOR TO CONSULT STRUCTURAL DRAWINGS in u H > W Y 1. TILE SIZE AND COLOR NOTED ON FINISH SCHEDULE.TILE TO BE THIN SET OVER ROOM NUMBER NOTED OTHERWISE. HOWEVER,IT IS EXPECTED THAT THE 29. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES 40. ALL MACHINERY,TOOLS,SERVICE, LINES, CONDUITS,SHALL BE BEFORE PERFORMING ANY WORK. W = Q O ID PREPARED SUBSTRATE. SURFACE PREPARATION IS THE RESPONSIBILITY OF THIS GENERAL CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK EXCEPT ITEMS TO BE REUSED OR AS OTHERWISE DIRECTED. GUARDED, SHIELDED OR BARRICADED TO PROVIDE SAFETY AND 59. CONTRACTOR TO COORDINATE FLOOR DRAIN LINES WITH f- u ' Q M M TRADE. NO ADDITIONAL COSTS WILL BE ALLOWED FOR SURFACE PREP. 1 WINDOW NUMBER WITH THAT OF HIS SUB-CONTRACTORS AND ANY OF THE CLIENTS 30. ALL DAMAGED EXISTING AREAS TO REMAIN AND EXISTING AREAS CONTACT BY THE PUBLIC. LOCATION OF SUMPS, DRY WELLS&PILES. _ W >- N N 2. PROVIDE TRIM SHAPES AS REQUIRED FOR EACH PARTICULAR APPLICATION, INCLUDING CONTRACTORS TO ASSURE THAT ALL SCHEDULES ARE MET. AFFECTED BY DEMOLITION OR NEW CONSTRUCTIONS WORK 41. WASTE MATERIALS OR DEBRIS SHALL BE REMOVED FROM THE 60. CONTRACTOR TO COORDINATE DIMENSIONS AND um Q O H N N 1 A14D 2 SIDED SURFACE BULLNOSED, COVED BASE, ETC. 15. THE GENERAL CONTRACTOR SHALL CONTACT THE OWNER TO SHOWN ON DRAWING SHALL BE PATCHED AS REQUIRED TO MATCH SITE DAILY. INSTALLATION OF ALL MATERIALS AND PRODUCTS AS PER O W 3. TILE JOINTS TO BE 1/16".TILE TO BE SET IN A GRID PATTERN. GROUT TO BE LATICRETE DETERMINE THE RULES AND REGULATIONS OF THE BUILDING FOR IMMEDIATE EXISTING ADJACENT IN MATERIAL, FIRE RATING, 42. MAINTAIN STRUCTURAL INTEGRITY OF ADJOINING WALLS, THE MANUFACTURER RECOMMENDATIONS. Q o 5) z f1 LL SERIES 1600 UNSANDED, FACTORY PREPARED, DRY GOUT MIX WITH LATEX ADDITIVE IN CONSTRUCTION,TO DETERMINE WHEN AND HOW DELIVERIES CAN FINISH AND COLOR, UNLESS OTHERWISE NOTED. GROUND AND PROPERTY AND PROTECT SAME FROM 61. GRIFFOLYN TX-1600 VAPOR BARRIER MANUF. BY REEF A COLOR TO TILE UNLESS OTHERWISE NOTED ON FINISH PLAN. BE MADE,WHAT PHASES OF CONSTRUCTION CAN BE DONE ON DISTURBANCE. INDUSTRIES TO BE USED BETWEEN CRUSHED STONE& REGULAR OR OVERTIME,AND IN GENERAL,ANY SPECIAL CONCRETE SLAB IN CRAWL SPACE THROUGHOUT.INCLUDE 4. PROVIDE SADDLE AT DOOR OPENINGS WHERE TWO FLOOR MATERIALS INTERACT. REQUIREMENTS WHICH WILL EFFECT THEIR WORK. PIPE BOOTS AND TAPING. .IQ DESIGINREVIEW rn C) 0 Lt- O d' Jo NEW ROOF TO MATCH EXISTING EXISTING ROOF BEDROOM BEYOND NEW ROOF TO MATCH p ROOF OVERHANG O EXISTING ROOF h_ OLL = O O oO p O p W O w U) O z NEW ROOF RIDGE_ _ — — — — NEW ROOF RIDGE — — — — � O � ov (ELEVATION = +00.00') (ELEVATION = +00.00') i CR X FINISHED SECOND FLOOR ATTIC SPACE N X (ELEVATION = +00.00') ATTIC SPACE D ARC s - 6-0" �g p HANGING LIGHT WALL SCONCE \\ VAULTED INT.CEILING / / \ \ '9j, ?3076 y0�� \ EXISTING LIVING FFRONT RENCH DOORENTRY \ ROOM\ BEYOND OUT-SWING CASEMENT WINDOW N RONT TRY NEW0 TNTRY 00 EAST =c? \ - - / \ / To SOUTH RAILING CLOSET EXTERIOR 0 STEPS / NEW INTERIOR FRENCH DOORS / / Q FINISHED FIRST FLOOR FINISHED FIRST FLOOR _ - °C _ _ _ W (ELEVATION = +00.00') (ELEVATION = +00.00') O NEW LANDING _ _ L81-011 U- (ELEVATION = +00.00) • ' " '" ~ Z ° NEW CRAWL .°• °. NEW CRAWL ,b:- O PROPOSED GRACE SPACE PROPOSED GRADE_ SPACE u- (ELEVATION = +0.00') (ELEVATION = +0.00') •' M S° W LV o I° ` ,I I I JL I I o O W U STACK CULTURED STONE BASE — coZ * .+ :• ' .i :• I I — :� ..' TO ALIGN WITH CONCRETE .j .:• I I I _ — I I I I I — — °• W ° u- '� Q EXISTING FOUNDATION WALL - W N • BASEMENT _ ui UJ IF } Z t0 = O W Lu 7 Ln J C� Ln O n a Ln m 5'-511 8'-10" 13'-10" - - - - - - 4"LAYER OF GRAVEL REINFORCED CONCRETE FOUNDATION WALL, 4"LAYER OF GRAVEL Z W F— QD J- ° I— z REINFORCED CONCRETE FOUNDATION WALLS. BACKFILL SEE STRUCTURAL DRAWINGS FOR DETAILS. BACKFILL Q U ca Q W 2;- SEE STRUCTURAL DRAWINGS FOR DETAILS. ' ' Z p. C7 CO Lu �hrs N t� O W Fz Ln _ J o- / ' � LLI N N U = z M 0000 H UJ ao 00 V > W �[ ►� I� H U m O 0 1.0 ko M M �s= Q co IW-- .N-� ,N-1 cl LLJ� N N < C2 mLnZa LL Law-1111m,Aff DESIGN REVIEW 99=. rn 0 0 LL.. O Ln EXISTING ROOF Jim NEW LIGHT GRAY VINYL CORNER TRIM BOARD EXISTING OR NEW VINYL SIDING EXISTING EXISTING EXISTING IXISIING EXISTING ROOF EXISTING WINDOW WINDOW WINDOW WINCOW WINDOW NEW LIGHT GRAY NEW ROOF TO MATCH VINYL CORNER EXISTING ROOF TRIM BOARD ROOF OVERHANG HANGING LIGHT BEYOND IXISTlNG ' EXISTINGdr WINDOW ♦` WALL SCONCE WINDOW / WINDOW EXISTING ♦ NEW SOLID COMPOSITE z PANELS TO CONCEAL Ln STRUCTURE AND FRAMING ♦ 11 A I ` _ pI nt 0 0 O ♦ ♦♦ ,, � � , O � pa� RAILING _ Lu oC EXTERIOR STEPS � O O T1 11 11 11 11 ri o X o x N X OUT-SWING CASEMENT WINDOW NEW LIGHT GRAY VINYL TRIM OUT-SWING CASEMENT WINDOW NEW CULTURED STONE BASE EXISTING GARAGE DOOR FRAME AROUND ALL WINDOWS HANDRAIL TO COVER EXISTING NEW LIGHT GRAY VINYL TRIM FRAME STACK CULTURED STONE BASE TO ALIGN WITH EXISTING FIREPLACE FIXED SIDELIGHTS FOUNDATION ED ARS AROUND ALL WINDOWS CONCRETE FOUNDATION WALL ��R ► ON L NEW FRENCH DOOR FRONT ENTRY �Ui� �D NEW SOLID COMPOSITE PANELS TOCONCEAL C CEA STEPS UP TO FRONT ENTRY y n� STRUCTURE AND FRAMING STACK CULTURED STONE BASE TO ALIGN WITH CONCRETE FOUNDATION WALL PROPOSED SOUTH ELEVATION PROPOSED EAST ELEVATION PROPOSED NORTH ELEVATION 30lro A OF NE`N SCALE: 1/4" = V-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" z O 0 Lu za o O LL Q z w O -I ()� W LL 0 3: W z z a � � O REMOVE EXISTING SHUTTERS U2: 0 a AT ALL EXISTING WINDOWS 1rn E"�I IE-� E'=_'�I IE' E=�1 LaL rt W Z I G=� K=�I I G=� r_ I I K=� C=�I Q I E=_ E=3 1 I E=3 E==31 I E=_ E_�1 p[ W N '-' IG=� W Z O U) E=_ E=_ i E=_ E=_ i E=_ E_=I L N W U' I E=_3 E=_31 I E=E3 E_=I I E=_ E=_31 }. H z 1 E_= E__1 I E=_ E=31 I E== E_=I W }. _ 11==� r_==fl I G=� K=�l I C=� r-=�I Ln - J U' H I E_� E__I I E_= E__I I E__ E__I OC =LjX m m OQ Lu 1--1 Z r �r Cllr -�IiTr �� r O p K a i ii iiii r-' rriiii ii i K G i -� I E=3 E=31 II 411 �A " IIII II I E=_ E=31 Ir- 1 '-r-� I E_3 E_=31 II 44 'I Ar'I 11 TNI II 1 E=_ E__I z I II 4U �I�I� �I I� 114 II I I I E__ E=3; I 11 114 1I II 1I IIII 4 IE__ E__Iri ri � iiii I C=3E=_ 3 ii -� EC==E�i1 VQ) IIII IIE_� E_�i u4 E_=I L__ _J Illi II II II �I V' I� IIII II IIII L__ __J Il ll Illlll tl IL'I I' 111111 IIII IIII I�IIII j1 11 It`ll 111111 IIII ♦ 11L------ w W r------------- ----- m H in ri 06 d N ri REMOVE EXISTING CONCRETE rq REMOVE EXISTING ENTRY �= = m 000 LANDING AND STEPS DOOR AND SIDE LIGHTS LVu w Z 00 00 REMOVE EXISTING CONCRETE LANDING AND STEPS W = Q O OC 10 1-0 �- U ,-i0mM EXISTING SOUTH ELEVATION EXISTING EAST ELEVATION EXISTING NORTH ELEVATION o � � oZ) Lu Z) Lu N N < wzati SCALE: 1/4" = V-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" DESIGN REVIEW rn 0 0 LiO 1.0 GFI PLUG MOLD OUTLET DEDICATED OUTLET FOR DISHWASHER ZL - - - - - - DEDICATED OUTLET r - - - - L MIM DEDICATED APPLIANCE FOR GAS RANGE I OUTLETS FOR EXISTING _ DEDICATED OUTLET I ( ELECTRIC WASHER BATHROOM FOR EXAUST FAN MIM j GFI PLUG MOLD OUTLET AND ELECTRIC DRYER (0—TNOWORK 4 � DEDICATED OUTLET EXISTING FOR REFRIDGERATOR I I I BEDROOM � NO WORK NEW KITCHEN MIM LAUNDRY CL. 202 201 EXISITING - - - - - - - - - - - - LIVINGROOM O EXISTING z STAIRS NO WORK 0 0 F- O b EXISITING LU EXISTING o o g GARAGE MASTER BEDROOM =) O) = z EXISTING NO WORK LL_ Ln O ,� O U DINING ROOM o EXISTING EXISTING x NO WORK BEDROOM BEDROOM o x NO WORK NO WORK N x II II II REARc DFC) CL CL 101 A ?3076NEW y0 I VESTIBULE I SOF NE� I II I 101 1I II I I II I I II I I I I I I II I I II I I I III III POWER PLAN 2ND FLOOR I III III I I III III , o L - - - - - - J SCALE: 1/4" = 1'-0" N Q w O LL Z 0 POWER PLAN 1ST FLOOR N w WSCALE: 1/4" = 1'-0" z z 2: 0w U Z LQi. � •� w z w N Q ELECTRICAL NOTES LEGEND w z o w a 1. ALL COVER PLATES TO BE DECORA STYLE AS MANUFACTURED BY NEW DUPLEX W z l0 Lu LEVITON. ALL TELEPHONE AND CABLE JACKS TO BE DECORA STYLE } = AS MANUFACTURED BY LEVITON.ALL RECEPTACLES,TELEPHONE H NEW QUAD OUTLET AND CABLE JACKS TO BE GANGED AS PER QUANTITY AT EACH Ln O n d d m LOCATION SHOWN. ALL WALL PLATES TO BE DECORA PLUS i SCREWLESS SNAP-ON. Z U C� m NEW DUPLEX DEDICATED OUTLET 2. ALL WIRING SHALL RUN IN GALVANIZED STEEL CONDUITS, BX O Q LU H :::P- FLEXIBLE FLEXIBLE CONDUIT, OR APPROVED EQUAL PER CODE. _.— . — . . NEW UNDER CABINET OUTLET STRIP 3. CONTRACTOR TO VERIFY LOCATION OF ALL SWITCHES, U RECEPTACLES AND LIGHTING WITH ARCHITECT PRIOR TO NEW TELEPHONE JACK O INSTALLATION. l< I J 4. CONTRACTOR TO VERIFY QUANTITY OF ALL PRODUCT TO BE USED NEW ETHERNET JACK PRIOR TO ORDERING AND PRIOR TO INSTALLATION. ��' Z FFI 5. CONTRACTOR TO VERIFY ALL POWER LOADS WITH ELECTRIC IV NEW CABLE TV JACK PANEL AND ADVISE OWNER AND ARCHITECT TO ANY w INCONSISTENCIES. MOTOR FOR RETRACTABLE AWNING 0 I 6. PROVIDE FOR CABLE N LINES IF REQUIRED. 0 7. CONTRACTOR TO PROVIDE ALL WIRING, CABLING,AND ® ELECTRICAL PANEL '-' LLI ELECTRICAL FIXTURES. CONTRACTOR SHALL VERIFY THAT THE DOOR BELL LOCATIONS,5'A.F.F. I-_ ABOVE MEET OR EXCEED LOCAL ELECTRICAL CODE. DB © CHIME LOCATIONS, l'BELOW FINISHED CEILING z Lr) 8. CONTRACTOR TO VERIFY WITH OWNER AND ARCHITECT THE TYPE od U OF ALL WIRING AND CABLING PROVIDED PRIOR TO ORDERING. SYMBOL TAGS d wrq 9. ALL EXISTING OUTLETS AND TELEPHONE JACKS TO BE REPLACED A-MOUNT 18"A.F.F. Z Ol 00 WITH NEW AS PER NOTE NUMBER ONE (1)ABOVE IN AREAS OF = w 00 00 WORK. B-MOUNT 48"A.F.F. W C-APPLIANCE/EQUIPMENT DEDICATED LINE.MOUNT HEIGHT Lu ~ > W Y W 2QO0� OtO 10. NO SURFACE MOUNTED CONDUIT, CABLES, OR BOXES IS IN ACCORDANCE W/MANUFACTURERS RECOMMENDATIONS. 16mmm I- U '-1 O m r'? PERMITTED UNLESS CONCEALED. CHANNELING OR CUTTING OFH = IR �- N (V STRUCTURAL SYSTEMS FOR PLACEMENT OF CONDUIT, CABLES AND D-MOUNT 4"ABOVE COUNTERTOP = Q p~0 I-w ,� FIXTURE BOXES IS NOT PERMITTED. U N r14E-MOUNT 42"A.F.F. 2: 05Uj 11. ALL SINGLE GANG OUTLETS MOUNTED ABOVE 18"A.F.F. SHALL BE Q Lf) z in- LL- ROTATED 90 TO HORIZONTAL UNLESS NOTED OTHERWISE. W-MOUNT 58"A.F.F. 12. ALL ELECTRICAL WORK SHALL BE COMPLETED BY AN ELECTRICIAN GFI-DENOTES GROUND FAULT CIRCUT INTERRUPTER LICENSED BY THE LOCAL MUNICIPALITY. EXT-WEATHER PROOF OUTLET W/HINGED COVER 13. ALL ELECTRICAL WORK SHALL BE PERFORMED BY ELECTRICIANS DULY LICENSED BY THE LOCAL BUILDING AUTHORITY. U-PROVIDE WIRING FOR UNDERCABINET LIGHTING DESIGNREVIEW rn C:) O O n UNDER-CABINET LIGHTS '\P) EWS EWS EWS EWS L - � 1 R UNDER-CABINET LIGHTS R II R Rim Ir . L - co L LI � HP _ HP_ HP , I I ( I ( IL - - - - - -- - --� 1 } R R _ R R / I- Rl yn I 1 } R R O Ln � R~ 0 O o � o � I o 0 o EXISTING PULL z:) cn = z DOWN STAIR U o U _T_ SWITCH TO �, X R I UPSTAIRS O x r�' X HALL LIGHTS 0 N X ED ARC, i 3 p M ��`pqs� I I H ?*r ro P ypQ' �� I OF NES I TR 1 I ws--�EHP EWS RCP PLAN 2ND FLOOR F- , J N SCALE: 1/4" = V-0" Q W u�- - - -- - - - - -�u 0 z RCP PLAN 1ST FLOOR ° z W W SCALE: 1/4" = V-0" N z z a 2: O U w V W N W z O Wuj Uj 0 kD In 'W' J C7 t - REFLECTED CEILING NOTES CONT. SYMBOL SCHEDULE CARBON MONOXIDE AND SMOKE DETECTING ALARMS AND DEVICES In 0 � a � m � z ca ca 1. EXISTING CEILINGS ARE TO REMAIN UNLESS NOTED OTHERWISE. 11. ALL CEILINGS TO BE 5/$" GYPSUM BOARD UNLESS OTHERWISE NEW DUPLEX z0 v 1. CARBON MONOXIDE AND SMOKE DETECTION ALARMS SHALL BE PROVIDED PER 908.7.1 AND 907.2.11.1 OF Q W CEILING SHALL BE PREPPED FOR NEW FINISHES AND FINISHED NOTED. LAMINATE AROUND BEAMS. THE 2014 BUILDING CODE RESPECTIVELY-OR MOST CURRENT VERSION OF BUILDING CODE.DEVICES SHALL C) n PER SCHEDULE. NO NEW THROUGH STRUCTURAL PENETRATIONS NEW QUAD OUTLET BE INSTALLED IN THE FOLLOWING LOCATIONS: Q 0 ARE PROPOSED THROUGH COLUMN & BEAMS. DROPPED CEILINGS 12. ALL INTERIOR FIXTURES TO BE ACCEPTABLE FOR WET/DAMP u SHALL BE INSTALLED PER NEW YORK STATE BUILDING CODE. LOCATIONS 1.1 ON THE CEILING OR WALL OUTSIDE EACH ROOM USED FOR SLEEPING PURPOSED WITHIN 15'FROM THE 0 0 0 NEW DUPLEX DEDICATED OUTLET DOOR TO SUCH ROOM --� 2. ALL WIRING TO BE FED THRU AND PROTECTED BY BX CABLE. 13. 'D' DESIGNATION ON SWITCH SYMBOL DENOTES DIMMER. T GALVANIZED STEEL RIGID CONDUIT IS ALSO PERMITTED PER CODE 1.2 IN EACH ROOM USED FOR SLEEPING PURPOSES z TO BE VERIFIED BY ELECTRICIAN. 14. ALL SWITCHES TO BE DIVA PADDLE STYLE AS - - - - NEW UNDER CABINET OUTLET STRIP L7 MANUFACTURED BY LUTRON. 1.3 DEVICES SHALL NOT BE INSTALLED WITHIN 20'OF COOKING APPLIANCES UNLESS LISTED IN ACCORDANCE 3. ALL SWITCHES TO BE DECORA STYLE AS MANUFACTURED BY _ _ _ _ NEW LED STRIP LIGHTS/ WITH THE 8TH EDITION OF UL 217 FOR SMOKE ALARMS OR THE 7TH EDITION OF UL 268 FOR SMOKE W LEVITON, COLOR TO BE WHITE OR APPROVED BY OWNER AND 15. ALL SWITCH PLATES TO BE CLARO SCREWLESS UNDER-CABINET LIGHTS DETECTORS PER BC14 907.2.11.5. 0 ARCHITECT. SNAP-ON AS MANUFACTURED BY LUTRON. ALL SWITCHES p(f TO BE GANGED AS PER QUANTITY AT EACH LOCATION. NEW DIMMER SWITCH 2. CARBON MONOXIDE AND SMOKE DETECTION ALARMS SHALL BE PROVIDED WITH PRIMARY POWER FROM 0 4. CONTRACTOR TO VERIFY ALL POWER LOADS WITH ELECTRICAL d MOUNTED @ 48"A.F.F. THE BUILDING WIRING AND THERE SHALL BE NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER lo" PANEL AND ADVISE OWNER AND ARCHITECT OF INCONSISTENCIES. 16. ALL LIGHTS TO HAVE MAGNETIC BALLAST. NO LIGHTS SHALL NEW THREE-WAY DIMMER SWITCH CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT. SECONDARY POWER SHALL BE FROM SEALED 10 LLJ BE PROVIDED W/ ELECTRONIC BALLAST. $ YEAR BATTERIES AND DEVICES SHALL INDICATE WHEN BATTERIES ARE LOW. 5. CONTRACTOR TO COORDINATE ALL SWITCH TYPES AND CAPACITIES d3 MOUNTED @ 48"A.F.F. Z � TO ACCOMMODATE LIGHTING LAYOUT. 17. ELECTRICIAN TO COORDINATE ALL SWITCH TYPES AND RECESSED LED LIGHT INTO HORIZONTAL PAINTED 3. DEVICES SHALL BE CAPABLE OF AUDIBLE AND VISUAL INDICATION IN ACCORDANCE WITH ANSI 117.1A-2009 06 u N CAPACITIES TO ACCOMMODATE LIGHTING LAYOUT. 0d r-1 BRIDGED BETJVEEN ROOF JOISTS -� +-i 6. CONTRACTOR TO VERIFY LOCATION OF ALL SWITCHES AND R 4. DEVICES SHALL BE INTERCONNECTED PER BC14 907.2.11.3 SO THAT WHEN ONE SMOKE AND CARBON . W N N LIGHTING BEFORE INSTALLATION WITH ARCHITECT. 18. CONTRACTOR TO VERIFY QUANTITY OF ALL PRODUCTS TO HP MONOXIDE DETECTOR IS ACTIVATED ALL SMOKE AND CARBON MONOXIDE DETECTORS SHALL BE �j = Z rn 000 BE USED PRIOR TO ORDERING AND PRIOR TO INSTALLATION. - HANGING PENDANT ACTIVATED. 0 W W 00 00 7. ALL NEW LIGHT FIXTURES SHALL USE HIGH EFFICACY LAMPS. �j � > W Y n N 19. CONTRACTOR TO VERIFY WITH OWNER AND ARCHITECT THE EHP W 2 Q O 0� 9.0 O 8. ALL ELECTRICAL WORK SHALL MEET OR EXCEED THE REQUIREMENTS TYPE OF ALL WIRING &CABLING PROVIDED. { EXTERIOR HANGING PENDANT V = ,-1 0 M M � W �"' NN ~ OF THE CALIFORNIA ELECTRICAL CODE, IN ADDITION TO ANY OTHER =V Q 00 ,-4 ,4 APPLICABLE OR SUPERSEDING CODES WITHIN THE JURISDICTION. 20. CONTRACTOR TO VERIFY AND PROVIDE FOR WIRING, EXTERIOR WALL SCONCE N N CABLING, ELECTRICIANS, AND FIXTURE TYPE TO MEET ALL Ews 0� 2: O W 9. ALL BULBS AND LUMINARIES SHALL BE L.E.D. TYPE UNLESS STATE AND LOCAL CODES. Q 0� m U) Z o_ LL NOTED OTHERWISE. ® NEW FLUORESCENT LIGHT FIXTURE 10. SURFACE MOUNTED CONDUIT, CABLES, OR BOXES ARE PERMITTED CEILING HEIGHT HIGHER AT THIS LOCATION DUE WITH STRICT ADHERENCE TO CLEAN AND DIRECT LINES AS ® TO UNIQUE FRAMING ABOVE APPROVED BY OWNER AND ARCHITECT. DESIGNI REVIEW rn 0 C:) O 00 ASPHALT SHINGLES TO MATCH EXISTING ROOF — CEDAR BREATHER BY BENJAMIN EXTEND DES OF DOOIR OPENING W/ CERTI-RIDGE VENT OBDYKE OVER ROOFING FELT METING SET IN BEDAOF ISEALANT LL H(BY OTHERS) TYPE 30 ROOFING FELT IF VERTICAL HEIGHT OF FLASHING IS LESS THAN 6 MINIMUM EXTEND KEMPEROL SOLID SHEATHING AS MEMBRANE FLASHING UNDER METAL SILL PLATE & REINSTALL SET SILL PLATE IN BED NOTED BY STRUCTURAL OF POLYURETHANES LANT. (RECOMMENDED MAINTAIN CONTINUOUS AIR FOR ALL CONDITIONS ENGINEER SPACE TO ALLOW MOVEMENT EREETENIP ANGLED RESIN TERMINATION OITS. OF AIR TO RIDGE VENT PREPARE LEVEL & PATCH SUBSTRATE AS REQUIRED W/APPROVED LEVELING COMPOUND PRIMER & MEMBRANE (TOP ) 5/4X6 AZEK FASCIA INSULATION WITH 2' KEMPEROL MEMBRANE FLASHING VAPOR BARRIER EXTEND 4" MIN. HORIZONTALLY ONTO FIELD SUBSTRATE. ASSURE FULL SUBSTRATE & OCOCOMPOSITE ALUMINUM GUTTER RESIN SATURATION OF F EECE 2X6 DOUBLE TOP PLATE 6" MINIMUM IN CORNER AREA. CONTINUOUS 4" WIDE STRIP OF KEMPEROL AZEK SOFFIT WITH 3" MEMBRANE © WALL TO DECK TRANSITION. CONTINUOUS VENT KEMPEROL FIELD MEMBRANE 2' THERMAL INSULATION, 5/4X4 AZEK TRIM MIN. R-18 2$1 z oU) 0 O= O O Luo o � DOOR SILL FLASHING Lo � 0 1 o X N.T.S. o X N X X 5/8" GYPSUM BOARD - �S� �'4Rc COATED COPPER OR FIRST FLOOR EQUIVALENT FLASHING APPROVED BY CULTURED STONE NEW WOOD BASE 'I ?3076 CHAMPAGNE SILL BY 4F t4 Y2'X1Y" AZEK TRIM CULTURED STONE. SWT-1370 NEW TREATED WOOD SILL PLATE (TYP) 3/4" WOOD FLOOR SUBFLOOR 3/4" GALVANIZED METAL BRACKET I 3�4 SHEATHING VENTED AIR SPACE METAL LATH OVER PLYWOOD r z NEW BLOCKING o WATERPROOFING MEMBRANE R38 FIBERGLASS BATT INSULATION o I INTERIOR FINISH PER SCHEDTJI 230 FLOOR JOIST. x� ce 3/4" AZEK BOARD MORTAR ::1Lu STUD WALL W/FIBERGLASS }' BATT INSULATION q a TERMITE SHIELD o PRO-FIT LEDGESTONE, WEATHER RESISTANT PLATINUMBARRIER OVER , BY CULTURED +' p< z SHEATHING OR SUBSTRATE STONE. PF-8017 HOT DIP GALVANIZED ANCHOR p a BOLTS AZACK TRIM BOARDS LINE OF FINISHED GRADE. w w -' GSM FLASHING SLOPE AWAY FROM HOUSE. _ =I I- 'j� z z W/DRIP EDGE I I=III—I II o CAULK AS REQUIRED GRADE - =III=III=III= p W CULTURED STONE Mi i 4 WATERTABLE/SILL 2 0" I I=III=III I I I I �- *-+ w O ° -III—III—III—I CRAWL SPACE z Lu o SIMPSON A-21 OR ~ II 10 POURED REIN. CONCRETE 1= — a o a w N � w w METAL BRACKET, HOLDING FOUNDATION WALL. SEE STRUC. -) I=I I—I I FOUNDATION WALL, SMOOTH FINISH, z CAPACITY 5 LBS./LF or = o PAINTED WITH BENJAMIN MOORE ECO � J ' MIN.22 GA. MTL. SUPPORT DWGS. I I (=III LATH SPEC PRIM aLn m __ ER AND PAINT O a SCRATCH COAT < m -I I I— r` r _ a CONCRETE SLAB, FINISH SMOOTH O U z <<; COATED COPPER FLASHING ,o; :: y MORTAR SETTING BED o 0 0 • • • a d Q LU �. CULTURED STONE VENEER a o Q 0 UENGINEERED STONE FILTER FABRIC VANEER 0 Q o VAPOR BARRIER: GRIFFOLYN TX 1600 -� CRUSHED STONE o o a MANUFACTURED BY REEF INDUSTRIES A CRUSHED STONE w TRI M D ETAI L STONE VENEER DETAIL 4 PERFORATED DRAIN PIPE Q Q o 0 0 CLOSED CELL COMPRESSION PAD °C 2 _ 3 � � cl�w Ln SCALE: 1-1/2" = 1'-0" SCALE: 1-1/2" = 1'-0" N a r-i � u z rn 00 w w w Y,00 00 TYPICAL WALL SECTION L_ ~ ' " '' 4 y62 w >- � " SCALE: 1" = 1'-0" � Q 2: O (- = w N N Q oC m Ln z a LL DESIGN REVIEW rn O 0 U- 0 SOLID SHEATHING W/ CEDAR co COMMON RAFTER — BREATHER. SEE STRUCTURAL DRAWINGS FOR SHEATHING DETAILS BARGE RAFTER CONTINUOUS BITUMINOUS PORK CHOP C END WATERPROOFING MEMBRANE BLOCKING AS REQUIRED W/ SPACE FOR VENTILATION ASPHALT ROOF SHINGLES, EXTENDED SOFFIT LEDGER CERTI-LAST COMMON RAFTER DOUBLE TOP PLATE LINE OF CORNER OF HCUSE SOFFIT LEDGER SHINGLES TO PROJECT 02' BEYOND FASCIA & 1" OVER RAKE END SOFFIT JOIST EAVE FLASHING 5/4"x6" AZEK FASCIA BOARD � z ALUMINUM GUTTER O ce CONTINUOUS MEMBRANE 5/4"x6" CONTINUOUS AZEK 0O o 0O SOFFITED EAVE / RAKE TRANSITION SOFFITED EAVE / RAKE TRANSITION EXTENDS 24 (MIN.) FASCIA BOARD 0 = 0 ,1 1 2BEYOND INNER FACE OF = O� LU P INSULATED WALL U-) o O ( CONTINUOUS AZEK SOFFIT Ln N.T.S. N.T.S. 36 FOR 3:12 TO 4:12 ROOFS) o X CONTINUOUS 3" SCREENED o x VENT W/ TRIM c X CONTINUOUS LEDGER FOR SOFFIT JOISTS 5/4"x4" CONTINUOUS AZEK TRIM 'd RFED ARC �G top Fn SOFFITED EAVE DETAIL M ` N.T.S. y>" 23076 y0 F0) NES z O THE BOTTOM EDGE OF FELT PAPER SHOULD 00 BE POSITIONED ABOVE THE BUTT OF THE Q ASPHALT SHINGLE AT A DISTANCE EQUAL TO TWICE THE WEATHER EXPOSURE. NEVER W TWO NAILS (ONLY) FOR EACH INTERLAY SHINGLES W/ FELT. 0 SHINGLE APPROXIMATELY -Y4FROM EDGE AND APPROXIMATELY 1Y" Z ABOVE EXPOSURE LINE. 0 U_ . w w SPACE ASPHALT Z Z SHINGLES 3/8" TO 5/8" APART w 2: 0 U EXPOSURE r., Lupi -�\� CERT(-RIDGE w N Q ASPHALT SHINGLE W Z w W ROOFING FELTZ �p � 0 SHINGLES SHOULD PROJECT 1Y2" / Ln � (�') O SOLID SHEATHING W/ CEDAR RIDGE VENT PRODUCT a BEYOND THE FASCIA & � � :D D O m APPROXIMATELY 1" OVER THE BREATHER. SEE STRUCTURAL INSTALLED TO MANU. tn_O rn a a_ m DWGS FOR DETAILS. CAULKING RECOMMENDATIONS GABLE OR RAKE END. Lil U z � SOLID SHEATHING © EAVE F___4 Q u_j ADJACENT COURSE JOINTS FELT AIR FLOW BACK FOLDED Q C) O SHOULD BE OFFSET 1Y2" MIN. EAVE PROTECTION AIR RIDGE O � Q DC ALUMINUM GUTTER _J STARTER COURSE FASCIA Z (7 V) Lu RAFTER O Ln ASPHALT SHINGLE ROOFING DETAIL RIDGE VENTILATION DETAIL W z dNr-1 40165N N.T.S. N.T.S. � z zrn00 Lu Lu ,0000 = < 0cecnM ON N O D W N N Q � OI (I� ZdLL DESIGN REVIEW-