HomeMy WebLinkAbout49144-Z .� TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 49144 Date: 4/20/2023
Permission is hereby granted to:
Hud ens, Thomas
340 E 23rd St A t PH 1 F
New York, NY 10010
To: construct additions and alterations (and to legalize as-built finished basement) to
existing single-family dwelling as applied for per SCHD approval. Additional
ceritifcation will be required.
At premises located at:
8555 Main Bayview Rd, Southold
SCTM #473889
Sec/Block/Lot# 78.-9-48
Pursuant to application dated 9/28/2022 and approved by the Building Inspector,
To expire on 10/19/2024.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $1,129.60
AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $660.00
CO-ADDITION TO DWELLING $50.00
Total: $1,839.60
gilding Inspector
s r TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone 631 765-1802 Fax 631 765-9502 htt� s // r"rw�".s0 ut .oldtc� n>1 -..&,)v
P ( ) ( ) w
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
PERMIT NO. Building Inspector,, ',
IL A'u u,:o
'711ill is
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date:9/28/22
OWNER(S)OF PROPERTY:
Name,-Thomas Hudgens, Christy Carter T 10010-78-09-48
Project address:8555 main Bayview road southold ny 11971
Phone#,347-325-4347 Email:tkhsecond a@gmail.com
Mailing Address:same as above
CONTACT PERSON:
Name:Clay Coffey, Margot Coffey
Mailing Address:430 Main Street 2nd Floor Greenport NY 11944
Phone#:347-276-6093 Email:clay@i aac-rae.com, margot@isaac-rae.com
DESIGN PROFESSIONAL INFORMATION:.
Name:Clay Coffey,-Margot Coffey
Mailing Address:430 Main Street 2nd Floor Greenport NY 11944
Phone#:846-275-2447 Email*clay@i aac-rae.co , margot@jsaac-rae.com
CONTRACTOR INFORMATION:
Name:
Mailing Address
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ®Addition RAlteration ❑Repair *Demolition Estimated Cost of Project:
❑Other $1,300,000
Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo
1
PROPERTY INFORMATION
Existing use of property:Single family residence Intended use of property:Single family residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? ❑Yes RNo IF YES, PROVIDE A COPY.
19 Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary Inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print in e):Clay f° y ®Authorized Agent Downer
�w
Signature of Applicant: Date:
CONNIE D.BUNCH
STATE OF NEW YORK) Notary Public,State of New York
No.01 BU6185050
SS: Qualified in Suffolk County
COUNTY OF ) Commission Expires April 14. 2
being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of Q =1 to la,)
Notary Public
PROPERTY( OWNER AUTHORIZATION
(Where the applicant is not the owner)
I,
residing at 8555 Main Bayview Road Southold NY
do hereby authorize clay Coffey to apply on
my behalf to the Town of Southold Building Department for approval as described herein,
�ner'sgnature Date
Print Owner's 'ame
2
y ro
00^40, Generated by REScheck-Web Software
LVIJ Compliance Certificate
Project 8555 Main Bayview
Energy Code: 2018 IECC
Location: Southold, New York
Construction Type Single-family
Project Type: Addition
Climate Zone: 4 (5572 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
8555 Main Bayview Road Isaac Coffey Isaac Coffey
Southold, ny 11971 Isaac-Rae Isaac-Rae
430 Main street 430 Main street
Greenport, ny 11944 Greenport, ny 11944
13472766093 13472766093
clay@isaac-rae.com clay@isaac-rae.com
Compliance: 22.7%Better Than Code Ma� III
ximum UA: 353 Your UA: 273 Maximum SHGC: 0.40 Your SHGC: 0.16
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
n
., t' r ,,",.v:w and rdc�pbl il.'t u�tawl w
•,,, ;,.�, +rviiir�rlr9ii7r,il9, .c�ri, ivil�.,l Iri�^4_I .iimiitIlr� , ..Il,_ iii^aral,,,lic�litl,.,
,a�l"7w.'iril,l lir Ilir. _;� Pli�, irri'. t � ^rrleyil,:,
Erre to e Assemblies
Cathedral Ceiling Over Addition:Cathedral Ceiling 1,415 30.0 10.0 0.025 0.026 35 37
Flat Ceiling Over Entry Connector:Cathedral Ceiling 1,415 30.0 10.0 0.025 0.026 35 37
Wall 1: Wood Frame, 16" o.c. 566 23.0 8.6 0.035 0.060 15 26
Door: Glass Door(over 50%glazing) 65 0.200 0.320 13 21
SHGC: 0.16
Window: Metal Frame w/Thermal Break 65 0.200 0.320 13 21
SHGC: 0.16
Wall 2:Wood Frame, 16" o.c. 566 23.0 8.6 0.035 0.060 20 34
Wall 3:Wood Frame, 16"o.c. 283 23.0 8.6 0.035 0.060 8 14
Window 1: Metal Frame w/Thermal Break 50 0.200 0.320 10 16
SHGC: 0.16
Wall 4: Wood Frame, 16" o.c. 283 23.0 8.6 0.035 0.060 7 13
Window 2: Metal Frame w/Thermal Break 70 0.200 0.320 14 22
SHGC: 0.16
Wall 5 Glass Entry Wall: Other 80 0.200 0.060 16 5
Wall 6 Glass Entry Door: Other 80 0.200 0.060 16 5
Floor: Slab-On-Grade(Unhealed) 144 10.0 0.360 0.360 0 0
Insulation depth: 2.0'
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 1 of 10
Basement Wall: Solid Concrete or Masonry
Wall height: 12.0'
Depth below grade: 10.0' 1,728 15.0 5.0 0.041 0.059 71 102
Insulation depth: 12.0'
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version: REScheck-Web and to comply with the mandatory r 4uirF
',,erifslisted in the REScheck Inspection Checklist.
r2
Name
Title Sli a f° Date
01"
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 2 of 10
All REScheck Software Version
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Pre-Inspection/Plan
.,..._ _m .—Plans Verified FielV Verified .W _.._' I._.. _
Section
Review I Complies Comments/Assumptions
03.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
_. ...m,.... w .. _ _ .a...............
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. []Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
w .. ._ .. _ ...__ ... .....mm _._.._
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual j or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
..1Hy .... „.. �....� act(T.ier 2.... .®... ,,.. ow m_
.p..a._c..t..(.�Tier 3)I h Impact(Tier 1) 2 Medium Imp"--
.M
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 3 of 10
Se& Req cts n
PlansVerifiedfled ....Field Valuefied p.. .� _...... ..
ID
# Foundation Inspection Com ies omments ssum ions
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values.
❑ Heated ❑ Heated ❑Not Observable
❑Not Applicable
...........en -------------------------- .....,-_ _ _... .... ..._.. ..........,. ._...,,__ ..... ,......
402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[F03]1 depth/length. ❑Does Not table for values.
[]Not Observable
❑Not Applicable
402.1.1 Conditioned basement wall R- _ R �� � �� ❑Compli
___ ._.� _ �.................... ....��mm n_�_n,..
es See the Envelope Assemblies
[F04]1 insulation R-value.Where interior R_ R- ❑Does Not table for values.
insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 ,,, , wall Conditioned basement -..
l ❑Complies
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions„
„ ❑Not Observable
❑Not Applicable
402.2.9 Conditioned
1 wall ft ft ❑ Envelope Assemblies
... table for -..,ss emblies
.......,.........
[F06] insulation depth of burial
al or ❑Dees Not values.
distance from top of wall.
❑Not Observable
_. .. ❑Not Applicable
cable. ..._
303.2.1Apotectivcovering
is installed ❑Complies
[FO1 1]2 pexpoeri exterior
❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
e-
403.9.., .® .,Snow-and ice-melting.. ..s..y......... .� _. _....._...
stem ❑Complies
[FO12]2 controls installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 jHtgh Impact(Tier 1) 2 IMedium Impact(Tier 2) 3 Low Irr�pact ier
(T +3)
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 4 of 10
S_...._ g__w_ _. 9 .p on Value Value
e .Complies? Comments/Assumptions_ .....__
Section Framing/Rough-In Ins ecti Plans Verified Field
Verified T
& Rec] ICS
. ...... ..
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ❑Not Applicable
... ---... __........... .. �._ ., .� __... . ........ ___._.- . ........... .................................. ...........
303 1.3 U-factors of fenestration products ❑Complies
[FR4]
1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. []Not Observable
❑
., ... ... __. ..._._,......... ..... ......w . ,
Not Applicable
402.4.1.1 _ Doe. .w ... __..._...__.... ...
Air barrier and thermal barrier Complies
[FR23]1 installed per manufacturer's s Not
instructions.
❑Not Observable
_ ❑Not Applicable
[0���3 Fenestration that is no. . --- ...... -.... �. .... .....---__...........
t site built ❑Complies
1 listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/i.5.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 ..._sealefixtures IC-rated recessed lighting ❑Com
g ures plies
at housing/interior/interior finish ❑Does Not
and labeled to indicate<_2.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.3.1 Supply
u.......I and ......- .
_._..... ... -.-.-.
pp y return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_
R-6 where< 3 inches.Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>=3 inches and R-4.2
for<3 inches in diameter.
4 OR.3.2 boxes..... _.mm_M..........filt... ..
®,......... ------.----------- _..e .. ...................... .__,w_..
air handlers and filter ❑Complies
1 are sealed with ❑Does.Not
joints/seams compliant with
International Mechanical Code or ❑Not Observable
International Residential Code, as ❑Not Applicable
applicable,
[3.3.5 duildi or
cavities are not used as ®Complies
. .. ......... — w ,. .................. ..
t
a plenums. ❑Does Not
[-]Not Observable
❑Not Applicable
[03.4 HVAC piping gFcoonveying fluids R- R- ❑Doe .w.._. _. _. ....m.mmm..
_... plies
above
r chilled fluids ❑ s Not
below 55°F are insulated to>_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC
C ❑Complies
[FR24]1 piping, ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 rt Hot water
_....._.__ ..... ---.._
pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
.,. ,.,, - ... ..�................ �..... ........................_.. ...�.._.
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
g p p (Tie 2) 3 Low Impact(Tier 3)
�..1. Hi h Impact(Tier 1) 2Medium Impact(Ti �. _.�__... 1
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 5 of 10
. .
AdditionalComments/Assumptions:
'
_,2"'Medium Impact(Tier 2) ow mpac ier
Project Title: 8555Main Bayview Report date: 09/25/22
Data filename: Page § oflO
WSection
Insulationnsp Inspection n Plans Verified Field Verified
_ Comp ies
,
S Comments/Assumptions
Value Value
SReq.ID
_ .....
303.1 All installed insulation is labeled ❑Complies m_.m
[IN13]2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R value. If this is a Wood ❑ Wood ❑Complies See^^ table eEnvelvaluEnvelope Ass... ....
emblies
es Not
l/3
402.2.5, mass wall with at least of the
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass []Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
____
303.2 Wall
lnunsulation i instructions.
❑Co
installed per 9 ElComplies ... --
es Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
G..... ... - _
1 IIHigh Impact(Tear 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier.
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 7 of 10
# Final Inspection Provisions Plans Ver fiedmm Field Verified —Complies? pJ+Comments/Assumptions� uwu......wv
..S�e�cton_
Value
Value
....,..
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.6
[Fill' ❑Not Applicable
.. instructions. ..
__ ....
.1.1, dingisulatstaldper ElComplies
303.2m manufacturer's ❑Doe
Not
(FI211 Blown insulation marked every ❑Not Observable
300 ftz.
❑Not Applicable
402.2.3 ' .Vented attics with air .. .. ....... .. .. _ _ ..._.._ ..,�.�,.. .......
permeable ❑Complies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies —
[FI3]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
. _.. _. ...,....... — — ....... ., .. ...... .... ........ _..
402.4.1,2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.3.3 Ducts are pressure tested to cfm/100 cf������/1 m lies �-
-------- __........ .
p m/100 ❑Complies
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure. _
403.3.4 Duct tightness test result of<-4 —_ ... .....�..... ...... _ .. . ....
g — fm/100 cfm/100 ❑Complies
[FI411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2.1 Air handl —� w. ... _
er leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
4..m—. ,. _ .—............— m ..,..,......._.............. �.�� _.. ....�. � _....
03.1.1 Programmable thermostats ❑Complies
[F1912 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat . -. u...... ®,.... „ w _rv.... _.__ .......... _ ...
pump thermostat installed ❑Complies
[F]10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot mm.........._. _ _. —.___.__...................... .....
�e . . water ❑Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium (Tim pact(Tier 3)
11 Impact(Tier 2) 3 Low Impact.mm.l.. .. ... —._
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 8 of 10
# i FinaInspection Value � .... ��a..n.r,., ...... ...
Final �� w_.. ....._...._
-T[ Fteq Puns Verified FieldValue
fied Complies? Comments/Assumptions
VV Provisions Co
403.6.1 All mechanical ventilation system ❑Complies
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and airflow limits per Table []Not Observable
R403.6.1. ❑Not Applicable
403.2 Hot water boilers supplying
_ — _-- m.m._............ �...�.. ...... ....... A.............._._
hea t ❑Complies
[FI26]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature. ..... .......... __ .....--- ......
__ - ....... ....--_ ........u..
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply []Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present, Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
. ., . . .. ....,_ . ._ . ---- �....... .. __ ..._.............._. .......
403.5.1.2 Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
m403.5.2 Demand recirculation water ❑Com
...a .. „__ ......._
plies
[F130]2 systems have controls that ❑Does Not
manage operation of the pump
and limit the temperature of the ❑Not Observable
water entering the cold water ❑Not Applicable
piping to<= 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[F13 1]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units <2 psi for
individual units connected to
three or more showers.
.. __ ........ ........ ...._., m .,...... ...., ,.....,.., e........... . .......... .............._
404.1 90%or more of permanent ❑Complies
[F16]1 fixtures have high efficacy lamps. ❑Does Not
❑Not Observable
❑Not Applicable
04.1. no ll gas liti pilot light.hs have ®„ - ElDoesplies
Not -__. ___ ____.. _ .............
ng
uous
❑Not Observable
❑Not Applicable
401.3 _Compliance certificate...posted.
❑Complies
[F17]2 ❑Does Not
❑Not Observable
❑Not Applicable
e w 2 Medium.. n.... _ i _ Y.,e
Hi h Impact(Tier 1) 2 Im act(Tier ow Impact(Tier 2 3 L3)
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 9 of 10
S_ect�on
u Plans Verified
Field Verified Final Inspection Provisions Complies? Comments/Assumptions
ValValue
& RedD[ .. ._._ _ , n_........_ ... ... ...
303.3 ....
...
Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
.._ .. _ ...__. 11,11--
.. p ..
9 p .. ier 2) 3 Low Impact(Tier 3)
1 Hi h Im act(Tier 1) 2 *Medium I.. act(T
Project Title: 8555 Main Bayview Report date: 09/26/22
Data filename: Page 10 of 10
12018
��u C Energy
kVIII li
Effidency Certificate
m m
Above-Grade Wall 31.60
Below-Grade Wall 20.00
Floor 10.00
Ceiling/ Roof 40.00
Ductwork(unconditioned spaces):
Window 0.20 0.16
Door 0.20 0.16
m m m m m ® u
Heating System::
Cooling System:
Water Heater:
Name: Date:
Comments
ICK k6l)RAIN
R MATERIAL ct of Record: - .�_m ... ..
N ` - PROVIDE SPEED ....
N LEVELER ON EACH"OUTLET
)LYLOCK DISTRLBUTION�BOX MARK Architect
C.... . ......� ........._,_ ....m. ...�. S — RAE
11575 Main Bayview Road
Southold, NY 11971
CONCRETE
COLLAR 24' Contact;PLUG Contact; Isaac Clay Coffey
NYS LIC#039767
:R AND
ER,"-777"
I60 T. 347-276-6093 E. clay@isaac-rae.com
-PVC PIPE"D3034
; .
SDR 35"__..__
AI„3 EP�„ TO SEPTIC
Project;
TANK 8555 MAI IN BAYV I EW
DWELLING
8555 MAIN BAYV I EW ROAD
cI so° PVC WYE SOUTHOLD NY 11971 _ ._ _._..... . ..
CI TO PVC HOUSE
ADAPTOR ..... Project No.:
I R-02
LEAN OUT DETAIL MARK "J” m
%2„ - 1 1 _'-p,.rwm.. "" Seal/Signature:
„
,CTMA 1000-78-09-48
le ARc
wamwxxa Wall
Ar
VP
w A
r � w
0
6 �_. ra I .
a„
Date. Scale:
0
yaha ii AS NOTED
P ��.... ..... �..�.. ._—._ _.,a.....
w t Drawing Title:
PROPOSED SEPTIC SITE PLAN
r
Drawing No.:
HEALTH DEPARTMENT APPROVAL STAMP 1 30
SURVEY OF PROPERTY
AT BA YVIEW
TOWN OF SOUTHOLD
SUFFOLK COUNTY N.Y.
1000-78-09-48
SCALE. V--50' for
MARCH 28, 2012 CORE
JUNE 18,M 2013 (CER77F7CA770NS) .s F1.0N tOT 1,0
OCTOBER 2, 2020 CMF S82'19'10"E / WIRE FENCE ALONG
FEN.COR.
JANUARY 25, 2021 (U77LIT7ES) o S'N j' DEER FENCE TOP OF WALL
MARCH 21, 2022 FE,
COR8•71 0.6'N
1.3'N C' ,NRY RET ". WIRE FENCE CMF
WALL CON �FEN.COi3; `yy mo .
* b'N It 0.4'N COR.EL
�y fi rY ; I tiJ3Z Ly' 0 TL6'. 33.2'
CID
rf Y MASOMAY
FIR£P.. E/ ,r3' POOL 0.
�! GAS PROPANE T I OVENya'`p' � �BEA>= r1 P^3 /'gVa7.
/
GAS LINE--. ON
CONIC.W _ e ry yP } e CMF \ 4
Q I COVE �yy
F �\�
STONE
WAL
ATI�?y OC STONE
y GAVECIUSIOE METAL EDGE } O �B.0 ��AlATxII,O
PL 84.3l HENT PUMPCE
Z STAKE 13 AC
�+ SET
41
roC
41 y FR.OUT. CHICKEN
J a/ _ OF sNowER COOP /may
1/1 735.0 �e ELEC.
, METERIx-
Ix STOIaE-RE'I'.aNING\ WIRE
aJW WALL
AN FPS 1 FEN.
'HEa
IR a .1a.a 1w.1`x
o 1W zB.
a4/ Tr y6
CS a 6, 7/W.13.4•LP
_n $
LOCATIOW Z' WIRE FEN. ,r� 4�' Q�'
'A' B' mow
Ln 2B' 535' 4 7/c
LP2 25' 421 �'k
�
GI
00
�/
B W= BOTTOM WALL EL
KEY -100,00, '4
REBAR
= RE6AR POUND /�y+a
�+✓ 7
A = WELL ( �
I► = STAKE 1
4i = TEST HOLE y4�
� = PIPE
CER77FIED TO.
■ = MONUMENT THOMAS K. HUDGENS �/
CHRISTY L. CARTER
WETLAND FLAG FIDELITY NATIONAL TITLE INSURANCE COMPANY
Va'= U77LITY POLE WELLS FARGO BANK, N.A.
UE = EXIS77NG UNDERGROUND ELECTRIC
—off— = EXIS77NG OVERHEAD WIRE
— EXYS77MG UNDERGROUND GAS LINE
L 0 T NO.s REFER TO"NAP OF HIGHWOOD AT BAYWEW FILE,{5547 AREA= 103,726 Sq.F't. or
Y.S.
ANY ALTERAflON OR ADD17701V TO THIS SURVEY IS A WOLA77ON OF ,238 Acres P . NO. 49616
SEC77ON 7209 OF THE NEW YORK STATE EDUCA770M LAW. EXCEPT PECONIC SURVEYORS, P.C.
AS PER SECTION 7209—SUBDIVI5I0N 2. ALL CERTIFICATIONS HEREON (631) 765-5020 FAX(631) 765-1797
ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY lF SAID MAP ELEVA77ONS AND CONTOUR LINES P.O. BOX 909
OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR KHOSE ARE REFERENCED TO NAVD. 1230 TRAVELER 57REET
SIGNATURE APPEARS HEREON. SOU7HOLD, N.Y. 11971 12-141