HomeMy WebLinkAboutClimate Control System at Town Hall Basement Records Storage rooms RESOLUTION 2023-341 ADOPTED DOC ID: 19040 THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION NO. 2023-341 WAS ADOPTED AT THE REGULAR MEETING OF THE SOUTHOLD TOWN BOARD ON APRIL 11,2023: RESOLVED that the Town Board of the Town of Southold hereby accepts the bid of Grattan's Heating & Cooling for the removal of old climate control system and installation of new climate control system in the Town Hall Basement Records Storage rooms for an amount not to exceed $24,300, per estimate#947 dated 1/12/23, all in accordance with the approval of the Town Attorney. This project shall be a legal charge to H.1620.2.500.675, Town Hall Basement. Denis Noncarrow Southold Town Clerk RESULT: ADOPTED [UNANIMOUS] MOVER: Jill Doherty, Councilwoman SECONDER:Brian O. Mealy, Councilman AYES: Nappa, Doroski, Mealy, Doherty, Evans, Russell ®�®vagFFoc�-�, DENIS NONCARROW �� off. Town Hall,53095 Main Road P.O.Box 1179 TOWN CLERK ® C* Southold,New York 11971 REGISTRAR OF VITAL STATISTICS ® Fax(631)765-6145 MARRIAGE OFFICER ® Telephone(631)765-1800 RECORDS MANAGEMENT OFFICER www.southoldtownny.gov FREEDOM OF INFORMATION OFFICER OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD April 12, 2023 Grattan's Heating and Cooling 322 Terry Ct. Southold NY 11971 Dear Mr. Grattan, Congratulations. At the regular Town Board meeting held on April 11th, 2023 the Town Board accepted the bid of Grattan's Heating and Cooling to install climate control systems in the storage rooms at town hall. A certified copy of the resolution is enclosed. Thank you for your bid. Ve trul yo , Denis Noncarrow Town Clerk Ens. - DENIS NONCARROW =� G.j� Town Hall,53095 Main Road TOWN CLERK p- P.O.Box 1179 COD Z Southold,New York 11971 REGISTRAR OF VITAL STATISTICS Q Fax(631)765-6145 MARRIAGE OFFICER Telephone(631)765-1800 RECORDS MANAGEMENT OFFICER �O! `1►a www.southoldtownny.gov FREEDOM OF INFORMATION OFFICER OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD April 13, 2023 Five Star Heating and A/C Inc 134 Sweezy Ave. Riverhead NY 11901 Dear Casey, At the regular Town Board meeting held on April 11th, 2023 the Town Board accepted the bid from Grattan's Heating and Cooling to install a Climate System in the Town Hall Basement. A certified copy of the resolution is enclosed. Thank you for your bid. Very truly yours, Denis Noncarrow Town Clerk Encl. o�oSaFF0j/r DENIS NONCARROW Town Hall,53095 Main Road P.O.,OWN CLERKBox 1179 C* y Z Southold,New York 11971 REGISTRAR OF VITAL STATISTICS Q Fax(631)765-6145 MARRIAGE OFFICER 'y RECORDS MANAGEMENT OFFICER ,( .� Telephone 765-1800 FREEDOM OF INFORMATION OFFICER www.southoldtldtownny.gov OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD April 13, 2023 Kolb Heating and Cooling PO Box 106 Mattituck NY 11952 Dear John, At the regular Town Board meeting held on April 11th, 2023 the Town Board accepted the bid from Grattan's Heating and Cooling to install a Climate System in the Town Hall Basement. A certified copy of the resolution is enclosed. Thank you for your bid. Very truly yours, Denis Noncarrow Town Clerk Encl. Grattan's Heating&Cooling Estimate -322 Terry Ct Southold, NY 11971 US (631)745-5555 grattanshvac@gmail.com Town Of Southold DPW P.O. Box 1179 Southold, NY 11971 7 7i ESTIMAl E#.? - :: DATE -~ — EXPIRATION: 947 01/12/2023 02/13/2023 RATE, : 01/12/2023 Installation 1 ! 0.00 _ 0.00 Remove and discard failed package systems for records storage. Furnish and install Rheem heat pump systems for each room. Installation includes (2) new outdoor heat pump systems with low ambient cooling capabilities model # RP1436AJ1 NA located in existing location on pre cast pads, (2) new Rheem air handlers model# RH1T3617STANJA located inb existing location in basement, (2) new electric heat strips size 10KW for each air handler, (2) pit 1`° new April Aire bypass humidifiers model<RP-6= located oneach airhandler, (2) April Aire dehumidifiers mod0 located on each air handler, reconnecting low voltage wiringan re urn ducting with new insulated transitions, insulated refrigerant piping, condensate drain piping, (2) new digital thermostats and all necessary materials and start up and testing of new systems. Investment Price 1 24,3010-00 ; 24,300.00 $24,300.00 Twenty Four Thousand Three Hundred Dollars Deposit 1 0.00 0.00, 50% upon signed contract 50% upon start up and completion Warranty 1 0.00 , 0.00, Manufacturers factory warranty on all parts during normal business hours i Note 1 ; 0.00 ; 0.00, Estimate has been constructed with the knowledge that this project is prevailing wage and will adhere to prevailing wage regulations Records storage at Town Hall TOTAL $24,300.00 Accepted By Accepted Date Grattan's Heating&Cooling Estimate _.322 Terry Ct Southold, NY 11971 US (631)745-5555 grattanshvac@gmail.com ADDRESS Town Of Southold DPW P.O. Box 1179 Southold, NY 11971 :ESTIMATE# DATE EXPIRATION DATE 947 01/12/2023 02/13/2023 ACTIVITY QTY: RATE AMOUNT 01/12/2023 Installation 1 0.00 0.00 Remove and discard failed package systems for records storage. Furnish and install Rheem heat pump systems for each room. Installation includes (2) new outdoor heat pump systems with low ambient cooling capabilities model # RP1436AJ1 NA located in existing location on pre cast pads, (2) new Rheem air handlers model# RH1T3617STANJA located inb existing location in basement, (2) new electric heat strips size 10KW for each air handler, (2) new April Aire bypass humidifiers model RE600M located on each air handler, (2) April Aire dehumidifiers model RE100 located on each air handler, reconnecting low voltage wiring, supply and return ducting with new insulated transitions, insulated refrigerant piping, condensate drain piping, (2) new digital thermostats and all necessary materials and start up and testing of new systems. Investment Price 1 24,300.00 24,300.00 $24,300.00 Twenty Four Thousand Three Hundred Dollars Deposit 1 0.00 0.00 50% upon signed contract 50% upon start up and completion Warranty 1 0.00 0.00 Manufacturers factory warranty on all parts during normal business hours Note 1 0.00 0.00 Estimate has been constructed with the knowledge that this project is prevailing wage and will adhere to prevailing wage regulations Records storage at Town Hall TOTAL $247300.00 Accepted By Accepted Date Noncarrow, Denis To: Hansen-Hightower, Kristie Cc: Abrams, Tim; Norklun, Stacey Subject: Climate systems Hi As we spoke,we received 3 quotes on the climate control systems in the basement of Town Hall.They keep the documents at a level of temperature and Humidity. Tim has 25,000 in one of his budget lines that he can use. The quotes come in at 37,750 Kolb 29,500 5 star 24,300 Grattan's At Prevailing wages. Is this all good Kristie. What else will you need to see. Thankyou Denis Noncarrow Southold Town Clerk. Town of Southold, New York www.southoldtownny.aov denisn@southoldtownny.gov 631-765-1800 CONFIDENTIALITY NOTICE: This communication with its contents may contain confidential and/or legally privileged information. It is solely for the use of the intended recipient(s). Unauthorized interception, review, use.or disclosure is prohibited and may violate applicable laws including the Electronic Communications Privacy Act. If you are not the intended recipient, please contact the sender and destroy all copies of the communication. a - s FIVE STAR HEATING&A/C INC. Estimate 134 SWEEZY AVE. RIVERHEAD, NY 11901 US (631) 298-9122 casey@5starhvac.com ADDRESS ": .I SHIP TO +' TOWN of SOUTHOLD TOWN of SOUTHOLD _ _ 5395 MAIN RD. 5395 MAIN RD. SOUTHOLD, NY 11971 USA SOUTHOLD, NY 11971 USA , i - -- i -----'- ESTIMATE# DATE I EXPIRATION DATE 1752 i 01/04/2023 j 02/03/2023 P.O. NUMBER SALES REP RECORDS STORAGE CJP ACTIVITY, Cay RATE ! AMOUNTi WE PROPOSE TO PROVIDE AND INSTALL THE FOLLOWING NEW H/C EQUIPMENT FOR RECORDS STORAGE AREA AT ABOVE LISTED LOCATION. i ' TWO[2]OF THE FOLLOWING HEAT PUMP SYSTEMS: -� rI COMFORT STAR EQUIPMENT OUTDOOR UNIT MODEL#CPR36-CD[O] INDOOR UNIT M#AHU36-SG2 COMFEAH-10B/10KW HEAT STRIP j APRILAIRE MANUAL HUMIDIFIER LARGE BYPASS MODEL# RE600M WITH HUMIDSTAT CONTROLLER NEW CONTROLLERS/THERMOSTATS 220V LGVCMA-20ULS CONDENSATE PUMP INCLUDED: INSTALL, MODIFY AND REHOOK TO EXISTING DUCT WORK j ALL REQUIRED LOW VOLTAGE WIRING ALL NEW REFRIGERANT LINES I REMOVAL AND PROPER DISPOSAL OF ALL OLD EQUPMENT j 1YR. WORKMANSHIP WARRANTY ! NOT INCLUDED: ANY PERMITS, DRAWINGS, LOAD CADS, OR RELATED PAPERWORK OR FEE'S ALL REQUIRED LINE VOLTAGE WIRING I j (electrician recommendation upon request) I IMPROVEMENT f 21,700.00 CAPITAL IMPROVEMENT j PAYMENT SCHEDULE: $10,850.00 AT CONTRACT 1 $5,425.00 AT START OF PROJECT ! $5,425.00-AT PROJECT COMPLETION IJ. THANK YOU FOR CHOOSING FIVE STAR HEATING AND AIR SUBTOTAL 21,700.00 CONDITIONING INC. TAX 0.00 TOTAL $21 ,700.00 Accepted By Accepted Date FIVE STAR HEATING&)VC INC. Estimate 134 SWEEZY AVE. RIVERHEAD, NY 11901 US (631) 298-9122 caseyL@5starhvac.com AbbRS�­ '_­' TOWN of SOUfkb" Lb' TOWN of SOUTHOLD 5395 MAIN RD. 5395 MAIN RD. SOUTHOLD, NY 11971 USA SOUTHOLD, NY 11971 USA F_srwATF_o i DATEi,EXPIRATION DATA ........... ........... 1758 01/17/2023 162/0,3/2,02'3' P.O. NUMBER SALES REP RECORDS ROOMS Cip WE PROPOSE TO ROVIDE AND INSTALL (2)TWO NEW APRILAIRE MODEL# RE100C DEHUMIDIFIER'S WITH BUILT-IN CONTROLLERS AND 115V CONDENSATE PUMPS. THRE WILL BE (1) ONE UNIT FOR EACH AREA FOR DEHUMIDIFICATION. 115V MAIN POWER FOR EACH UNIT AND PUMP IS NOT INCLUDED AND WILL NEED TO BE PROVIDED BY CUSTOMER'S ELECTRICIAN. CAPITAL IMPROVEMENT 21 3,900.00 7,800.00; INSTALLATION -- THANK YOU! SUBTOTAL 7,800.00 TAX 0.00 TOTAL $7,800.00 Accepted By Accepted Date Page No. 1 of 3 Pages kolb11500 Old Sound Avenue, PO Box 106 Mattituck, New York 11952 P 631-298-55271 F 631-298-5534 HEATING + COOLING www•kolbmechanical.com PROPOSAL SUBMITTED TO PHONE DATE Town - &7 Mary-2,-2023 STREET JO NAME P.O. Box 1179 53095 Main Road CITY,STATE AND ZIP JOB LOCATION Southold, NY 11971 Southold NY 11971 EMAIL ADDRESS CELL PHONE TimA@southoldtownny.cov JZ/95 We hereby submit specifications and estimates for, Remove and discard the two (2) existing Liberty heating and air conditioning system which serve the Records Room. Utilizing the existing supply air distribution ductwork, provide and install two (2) new Mitsubishi P-Series ducted Variable Refrigerant Flow high efficiency heat pump heating and air conditioning systems to consist of the following: Scope of Work: • Provide all engineering for the design and installation of the HVAC system. • Equipment and ductwork shall reside within the semi-conditioned building envelope. • Provide and install all necessary additional supply air distribution ductwork and all new return air distribution ductwork, insulated as per New York State Energy Conservation Construction Code. • Provide and install flexible connectors at the supply and return connections. • All new sheet metal return ductwork to be internally lined with sound attenuating acoustical liner. Liner to be fastened by means of glue and mechanical weld pin fasteners. • Provide all necessary ductwork modifications and new ductwork transitions to accommodate the new air handler configurations. • All new duct seams to be sealed with UL181 metal foil tape. • All new visible distribution plenum boxes to be painted-with flat black paint. • Provide and install two (2) Mitsubishi M-Series, model #PVA-A24AA7, 24,000 BTU, ducted multi-position high efficiency fully modulating fan coil unit, complete with all necessary controls. • Provide and install two (2) Mitsubishi M-Series, model #PUZ-A24NKA7, 24,000 BTU, Variable Refrigerant Flow high efficiency outdoor heat pump condensing unit to be installed at the residence exterior, exact location to be determined. Unit shall be set on a pre-cast slab. • Provide and install two (2) AprilAire, model #2213, 5"thick MERV-13 HEPA extended media type air barters. • Provide and install vibration isolators for all motor bearing equipment. *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,until fully paid All past due accounts shall be charged interest of 1.5%per month. All payments Due Upon Receipt. 'JC'JCOpOBC hereby to fumish material and labor—complete in accordance with above specifications,for the sum of: Base Total Options Total Grand_Total Payment to be made as follows: Ali material is guaranteed to be as specified. All work to be completed in a Workmanlike manner according to standard practices.Any alteration or deviation from above specifications involving extra Authorized costs will be executed only upon vmtten orders,and will become an extra charge over and above the Signature estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Owner to carry fire,tomado and other necessary insurance. Our workers are fully covered by Workman's Note:This project may be Compensation Insurance. withdrawn by us if not accepted within 16 ;ZJCCOpfnJJCC Of VCOOPOOfir The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Print Name Date of Acceptance Signature Page No. 2 of 3 Pages � �aaaY [®R 11500 Old Sound Avenue, PO Box 106 Mattituck, New York 11952 P 631-298-5527 1 F 631-298=5534 H E AT I NG + COOLING www•kolbmechanical.com PROPOSAL SUBMITTED TO PHONE DATE Town of Southold - hr� f STREET JOB NAME P.O. Box 1179 53095 Main Road CITY,STATE AND ZIP JOB LOCATION Southold, NY 11971 Southold NY 11971 EMAIL ADDRESS CELL PHONE TImA southoldtownny.00v JZ/gs We hereby submit specifications and estimates for: Scope of Work (Continued): • Provide and install Armorflex cleaned and capped insulated type 1' nitrogenized refrigeration piping. • Charge refrigerant circuit with new R-410A Puron non-ozone depleting environmentally compliant refrigerant. • Provide and install all condensate schedule 40 PVC piping for the HVAC system. • Provide and install Hart&Cooley grilles and registers, where necessary. • Provide and install two (2) Mitsubishi remote thermostat controller. • Provide and install all low voltage HVAC control wiring. • Coordinate power wiring load requirements and power wiring schematics with the electrician. • Perform all testing and balancing of HVAC system upon start-up. • System to include a one (1) year parts and labor service contract. Excludes: • Line voltage power wiring, by Electrician. • Cutting, patching, painting, and/or framing of sheetrock, and carpentry for HVAC, if required. • Specialty grilles/registers and materials/finishes. • Any applicable permits, certificates, or associated fees, if required. Warranty: • All work to be done in a professional manner by trained installers and service personnel. • One-year parts & labor service during'normal business hours on above system. • Exclusive Mitsubishi Elite Diamond Dealer Twelve-year parts and compressor warranty. • All factory warranties honored. Total Investment: $ 37,750.00 *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIA CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain properly of Kolb Mechanical Corp.,until fully paid All past due accounts shall be charged interest of 1.5%per month. All payments Due Upon Receipt. STC I)COpOOt hereby to furnish material and labor—complete in accordance with above specifications,for the sum of: Base Total Options Total Grand Total Payment to be made as follows: All material is guaranteed to be as specified. All work to be completed in a workmanlike manner } according to standard practices.Any alteration or deviation from above specifications involving extra Authorized J costs will be executed only upon written orders,and will become an extra charge over and above the Signature-' estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Omer to _. carry fire,tomado and other necessary insurance. Our workers are fully covered by Workman's Note:This project ay be Compensation Insurance. withdrawn by us it not accep ed within 16 21cceptrmce Of Vt11d$1oorif The above prices,specifications and conditions are satisfactory an are hereby accepted.'You are authorized to do the work as specified. Payment will be made as outlined above. I Print Name Date of Acceptance j(Signature Page No. 3 of 3 Pages 11500 Old Sound Avenue, PO Box 106 i k o I b Mattituck, New York 11952 P 631-298-5527 1 F 631-298-5534 HEATING + COOLING www•kolbmechanical.com PROPOSAL SUBMITTED TO PHONE DATE Town o 6047 Fehrilary 2 217121 - STREET JOB NAME P.O. Box 1179 _ 53095 Main Road CITY,STATE AND ZIP JOB LOCATION Southold, NY 11971 Southold NY 11971 EMAILADDflE55 CELLPHONE TimA@southoldtownny.gov JZ/gs We hereby submit specifications and estimates for: Please initial beside any accepted option/s: - Option #1 - Humidification with Fan Pac: Provide and install one (1) AprilAire immersed electrode high output steam humidifier with a stainless-steel steam dispersion tube. Humidification system to be configured to operate in conjunction with, or independently of a call for heating. Includes all necessary materials, labor, installation and start-up. Additional Investment: $ 3,150.00 I - Option #2 - Dehumidification: Provide and install one (1) AprilAire standalone dehumidification system to consist of the following: ® One (1) AprilAire, model #E100, ducted dehumidification system. Includes: • Kindorf support system. • Schedule 40 PVC condensate drain piping. • Low voltage HVAC control wiring. • All necessary materials, labor, installation and start-up. Additional Investment: $ 4,200.00 *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,.until fully paid All past due accounts shall be charged Interest of 1.5%per month. All payments Due Upon Receipt. =t Teopose hereby to furnish material and labor—complete in accordance with above specifications,for the sum of: Please print grand total below; including any accepted option/s: Base Total Options Total Grand Total Payment to be made as follows: Snot Deposit; 90oye43a1ar4Ge—pt:4e— In All material is guaranteed to be as specified. All work to be completed in a workmanlike manner , according to standard practices.Any alteration or deviation from above specifications involving extra Authorized costs will be executed only upon written orders,and will become an extra charge over and above the Signature estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Owner to carry fire,temado and other necessary insurance. Our workers are fully covered by Workman's Note:This project may be Compensation Insurance, withdrawn by us if not accepted within_-_ 16 21CCeptnnte of VWPID0111 The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Print Name Date of Acceptance_—__ X Signature 5s � �1700 7Qoo assoa By Ernest A. Conrad, PE March 1999 There is a popular misconception that a realistic environmental criteria to preserve artifacts is that which is a compromise between opposed needs of the building, the occupant, and the collection at a cost which an institution is willing to pay. This philosophy completely misses the mark. Too much of our history has been lost using this rationale. A'realistic environment is not a compromise where two extremes are averaged into one, such that neither is appropriate. But rather, it is a balance in which the different needs can all be satisfied through a realistic analysis of factual data followed by cost conscious design choices to achieve that end, both in first cost and operating cost. In the "realistic" world, this philosophy is often easier said than done. But it's not really all that difficult, so long'as the design choices focus on factual measured data, from both the past as well as the present. How then does one achieve this cost conscious balance? There are over 8,000 different combinations of climate control design choices in the commercial marketplace today. Only a step-by-step logical process of analysis will succeed in arriving at the one choice most appropriate. It is a team process which can be divided into the three following steps: • classify envelope • identify heat loads • perform moisture inventory Classification System A classification system has been developed by Landmark Facilities Group, Inc., in which all buildings or individual room spaces are divided into classification categories. Each category represents structures of similar thermal characteristics limitations. The kinds of collections each group might house safely is then identified. Occupancy limitations are also given. In all, there are three climate control categories. They are: uncontrolled, partially controlled, and climate controlled. Each has two sub-level classifications. Table 1 summarizes the classification system and Table 2 presents preservation approach examples. UNCONTROLLED -An uncontrolled building would have no installed systems for heating or cooling. Type I - No Mechanical Devices -A Type I structure is the simplest form of construction which is an open structure. Examples would include objects such as covered bridge, open sawmill, a privy, stocks, a well or gazebo. Environmental conditions in this Type I structure would essentially equal the outdoors. In temperate climates the temperature would likely range from 100°F (38°C) in summer to -10°F (-25°C) in winter. Humidity levels would range from saturation (100%RH) down to lows of perhaps 20%RH. It is noted that it is rare for humidity levels to fall below 20%RH in an unheated structure. The overall annual humidity range in a Type I structure would then be +/-40%RH. The kine of collections that may fare well in a Type I structure would be hardy materials such as farm tools, wagons, sculptures and the like. This is a good location to use reproductions or common materials which can be readily replaced. Obviously, these buildings would have no comfort occupancy use. Type II -Ventilation Only -A Type II structure, also has no systems for heating or cooling, but it is enclosed on its sides and above for basic weather protection. Examples would be sheathed post and beam buildings such as a barn, shed, silo, cabin, or icehouse. Environmental conditions would be naturally improved over a Type I structure slightly, however infiltration rates would be high and day/night thermal "coast" would be small. Exhaust fans and natural venting would help reduce summer high temperatures and high humidities. In winter, it would rarely fall much below freezing inside and the natural infiltration would help dilute unwanted, internal moisture levels. Temperature would generally range from 90°F (36°C) to 32°F (0°C) over a years time. With no heating, humidity levels may likely vary from a high of 90%RH to a low of around 30%RH, or 30%RH year round. The kinds of collections that would be relatively safe in these structures would be hardy collections. These might consist of tools, machinery, wagons, carriages and vehicles. Again, educational reproductions and other common materials would be appropriate here. In.a museum setting, none of these buildings would have comfort occupancy use except for specific events such as perhaps an open hearth cooking demonstration. PARTIAL CONTROL - Buildings in the partial control category have some kind of mechanical systems installed to produce temperature control only. No specific devices are installed to add or remove moisture in a precision fashion. Type III - Heating and Ventilation - Type III structure would have a practical limit of climate control consisting of simple-low level tempered heating and exhaust ventilation. Typical construction features would consist of wood framing and siding or masonry. Windows would be single glazed and no insulation materials or vapor retarders would be present. Examples would be a rough frame house, boat, train, lighthouse, carriage house, or industrial workshop. By combining the use of exhaust fans in summer and minimum heating in winter, temperature conditions might likely be controlled between 80°F (26°C) in summer and 50°F (10°C) in winter. With no specific humidity control devices, humidity levels would likely drift from a high of 70%RH to a low of 30%RH. Thus, the usual range of humidity would be +/-20%RH. The kinds of collections that might be relatively safe within these facilities would cover a fairly broad range of materials which are not sensitive to fluctuations. Simple period room furnishings, hardy textiles, metals, ceramics, and common household goods would be reasonably protected. Highly restrained collections such as inlays or extremely sensitive compounds should be removed during seasonal extremes or separately controlled using buffered cases or similar. It is important to recognize that wintertime occupancy would not be permissible in rooms where these collections are exhibited or stored. Room temperature must be maintained below the normal comfort range at these times. Type IV - Basic HVAC -A Type IV structure would have a ducted system of heating and cooling. The system may also be capable of limited humidification and dehumidification re- heat depending upon the specific building's perimeter envelope construction. Typical building Construction features would be heavy masonry walls or composite framing with plastered walls over several layers of wood. The general construction would be tight with low infiltration. Modest insulation characteristics would be present, along with storm windows. Attics would be insulated and vented to the outdoors. Examples of buildings would be a finished home, church, meeting place, store, inn or modern commercial building. With an ability for year round temperature control and limited humidity control, environmental conditions in a Type IV building that holds collections would range in temperature from 75°F (24°C) in summer to about 60°F (15°C) in winter. Winter ambient above 60°F (15°C) could only be permitted with active monitoring in place to demonstrate a condensation free perimeter envelope. Relative humidity could be held below 60% RH in summer and around 30%RH in winter. Thus, the year-round humidity range would be +/-15 %RH. The kinds of collections that would be relatively safe in these buildings would cover a host of museum materials including books and other paper-based collections. Again, it must be recognized that winter occupancy must be limited in these facilities in order to protect both the building and the collections. Continued monitoring must be employed to assure the safety of this delicate balance. CLIMATE CONTROLLED - Buildings in the climate controlled category are generally specifically designed from their outset to be humidified structures. Few buildings fit in this category naturally. Systems in these buildings have the ability to accurately control both temperature and humidity levels year round. Type V - Climate Control with.Drift - Type V facilities are equipped with ducted HVAC systems which also contain devices to mechanically humidify and perform process logic to dehumidify. These systems may be capable of year-round constant climate control without any drift, but are chosen not to function that way. Scheduled seasonal drift is intentionally selected by the user for either of two reasons. One reason might be the building simply can not tolerate outdoor winter extremes without condensation forming at its perimeter envelope. The other reason may be basic cost economics relating to the intense energy consumption required to achieve summertime room ambient conditions of certain temperatures and relative humidities. Buildings in the Type V group are all well insulated structures having at least double glazing, good vapor retardant characteristics, and vestibules leading to the outside. Examples of these buildings would be museums, research libraries, galleries, and storage buildings. By having complete climate-control capability and accurate controls devices, temperature and humidity environments in these facilities can generally be chosen at will. Reasonable ranges of conditions might be a summer high temperature of 75°F (24°C) and an occupant winter comfort of 70T (21 CC). Over the course of a year, the humidity levels may be chosen to drift from, perhaps, a winter low of 35%RH to a summer high of 55%RH. This would yield an overall annual humidity range of+/-10%. Controls instrumentation in these facilities would need to have an accuracy of about +/-1°F and +/-2%RH. The kinds of collections that would likely be safe in these structures would consist of all, but the most delicate of materials. Museum quality collections of fine arts, inlays, conserved collections, and finely crafted arts should all be safe here. There would be no occupancy restrictions relating to user comfort in these facilities. Tyt'e.V!-a Special Constant Environments -Type VI facilities are specifically constructed to accommodate specialized environmental needs for a particular purpose. Precision climate control systems with specialty components are employed. These structures are generally small in size due to their high construction cost and operating cost. Examples are vaults, storage rooms, and specialty cases or enclosures. Environmental conditions in these structures are specifically designed for their contents and are held constant within the limits of the chosen technology of precision accuracy. Temperature could likely be maintained between 70°F (21 °C) and 68°F (2°C) year round. Humidity levels might be selected to range between 50%RH and 40%RH or even smaller. This range presented is an overall annual +/-5 %RH. Controls instrumentation in these facilities would have an accuracy of+/-1 OF and +/-1%RH or less. These facilities are what might be considered the "intensive care" rooms for materials deemed to need special care. The materials might include unique minerals, chemically damaged objects such as some bronzes, composite materials with mismatched expansion coefficients, some photographs and perhaps extremely old materials. Only limited access would be permitted in these facilities. Human comfort would have no priority; only the collections would be protected. IDENTIFY HEAT LOADS Once the natural thermal limits of a structure are known, it is then put to the test mathematically, as six heat loads are imposed on it. These heat loads are as follows: • Solar- This is the heat energy of the sun which passes through glass windows, doors and skylights. It changes minute by minute and represents 10 times the heat energy of others but only in the concentrated point where its light lands. • Transmission -This is heat energy that moves through a wall or roof caused by a temperature difference on either side. This heat load is most significant in winter when the difference between inside and outside are as much as 70°F (21'C) . During summer, the influence is only one"third this amount. • Lights - Lights and other electric devices are significant heat contributors to a space. However, they only contribute when they are on. Therefore, they can represent 90% of the heat added to a room when occupied and 0% when not occupied. COUNTY OF SUFFOLK STEVEN BELLONE SUFFOLK COUNTY EXECUTIVE OFFICE OF CENTRAL PROCUREMENT NOTICE OF CONTRACT UPDATED VERBIAGE - MISSING FROM BID MASTER AGREEMENT ANNUAL REQUIREMENTS HVAC- SERVICE AND NEW INSTALLATION COMMODITY CODE: 91036 CONTRACT: CONTRACT#: ACRI101921-P INITIATING DEPT: DPW OPENING DATE: 09-15-2021 1494 PERIOD OF CONTRACT: 10-19-2021 THROUGH 10-18-202x2 BID #: 21/0218LPWI VENDOR: PREMIER MECHA L SERVICES, INC. 1493 CHURCH ST ^ q6,q(t,1741 HOLBROOK NY 1 C�L S VENDOR ID: VC0032994 J CONTACT: KIM PAULICELLI Qom.lei CV"; 1, PHONE: 631-956-1112 FAX: 631-956-1113 EMAIL: KIM@ PREMIERMECHANICAL.NET ADDITIONAL VENDORS: CLICK HERE DETAIL PAGE: CLICK HERE ATTACHMENT: DELIVERY: FOB - DESTINATION POLITICAL THIS CONTRACT IS AVAILABLE FOR USE BY OTHER MUNICIPALITIES SUBDIVISIONS: FOR FURTHER INFORMATION JESSICA RIDGE CONTACT PURCHASING AGENT: 12-06-2021 SUFFOLK COUNTY IS AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER (631) 852-5196 335 YAPHANK AVENUE YAPHANK, N.Y. 11980 FAX (631) 852-5221 Return to Contract List I Return to Search Page For technical assistance or technical comments CLICK HERE WSE CERTIFIED 1493 Church Street Premier Rilechanical Services Holbrook,NY 11741 Engineering a new dynamic. p(631)956.1112 F(631)956-1113 CotitractoWMvier Project 11, Date Design Documenis Southold Town Hall Route 25 Southold Town Hall 53095 PO Box 2 53095 Main Rd 9/20/22 All work to be done in accordance Southold NY,11971-0959 Peconic,NY 11958 with Contract#ACRI101921-P Split AC Replacement A":Tim Abrams FROMM •As per your request,we are pleased to provide a budget proposal to replace two 3 ton Liebert split systems for Southold Town Hall records room. Scope of work includes but is not limited to: •Rigging services will be provided to remove existing units&install new. •Removal and disposal of existing freon in accordance with EPA regulations. •Provide two new 3 ton condensing unit&air handler in records room. •Existing refrigeration lines replaced due to new freon being used. •Disconnect and reconnect all control and power wiring. •The existing domestic water piping will be reused and connected to new unit for humidification. •A new refrigeration charge R410A for new units. •Supply and install new refrigeration dryers and site glasses and refrigeration piping accessories required by the manufacturer. •Modify existing supply&return duct to match new units. •Start-Up&1 Year Parts Warranty. •Units to be provided with factory built in controls. •No integration into existing BMS is included. •Insulation will be installed on piping. General Exclusions •Dumpsters •Gas Piping •Duct Smoke Detectors •Building Management System •Structural Steel Dunnage •Premium Time Work •ICRA Partitions •Fire Alarm Wiring •Carpentry Openings •Overtime Labor •Roofing&Flashing •Painting •Masonry Openings •Permits&Fees •Fire Stopping •Ductwork •Fire Smoke Damper Monitoring •Controlled Inspections •Temporary Heating&Cooling •Controls on BMS •Warranty •Any Parts NOT Mentioned Above •Maintenance/Inspections •Filter Changes •Testing&Balancing Proposed Price Proposed Price for This Project-$159,076.50-ONE HUNDRED AND FIFTY NINE THOUSAND DOLLARS, SEVENTY SIX DOLLARS AND FIFTY CENTS. We would like to thank you for considering Prein ler Mechanical and look forward to working with you. Sdould you find this proposal acceptable, please sign and return original to our office. This proposal is valid for Thirty(30)days from this date and is subject to the addition of all applicable sales taxes unless a satisfactory tax-exempt certificate is supplied prior to the start ofthe iab. PREMIER MECHANICAL LSA NYS CERTIFIED IIBE Proposal prepared by: ICacie DeLuca,Junior Estimator P:(631)956-1112 Accepted by: Signature&Title: Date: ti WBE CERTIFIED Premier E new nechannd Services Engineering a new dynamic. Project Estimate Sheet Project: Southold Town Hall Liebert Unit replacement Date: 9/20/2022 Labor . . , Trade Hours Rate Cost Notes Steamfitter $157.00 $0.00 Sheet Metal Worker $155.00 $0.00 Service Technician 24 $117.00 $2,808.00 Pump Down/reclaim/disconnect existing units Service Technician 16 $117.00 $1,872.00 Leak Detectors/terminate Low Voltage Service Technician 16 $117.00 $1,872.00 Start-Up Service Technician 48 $137.50 $6,600.00 Piping/Install/Rigging Project Supervisor 8 $125.00 $1,000.00 Labor Subtotal'`;: $14,152:00 Material.&.Equipment Description Vendor Cost Notes AC Units Liebert $93,760.00 See attached quote for current leadtimes on equipment Piping $4,700.00 Freon Johnstone $500.00 Reclaim Johnstone $75.00 Nitrogen Johnstone $75.00 Refrigeration Specialties Johnstone $2,300.00 Dryer,Siteglass Virbration isolation Grainger $220.00 . Pad's for indoor and outdoor units Material&Equi'pment Subtotal $101;630.00, = Material&Equipment Markup(15%) $15;244:50.. , Material&:Equipment Total $716,874.50'p Subcontract ars, Description Vendor Cost Notes insulation Twin Forks $5,200,00 Ductwork SCH $9,600.00 Rigging/Diconnects/Install Clean Up East End $2,500.00 Demolition and unit removal Rigging A&J $2,600.00 Electrical Rolands Electric $5,600.00 Power wiring and Control conduit SubcontractorSubtotal $251500.00 Subcontractor.rdarkup(10%) $2,55o.00 Subcontractor Total $28;050.00' Labor $14,152.00 Equipment&Material $116,874.50 Subcontractor $28,050.00 Grand Total :; $lwi076.50. e� Manhattan Office Plainview Office 1 Penn Plaza, Suite 1500 125 Newtown Rd., Suite 360 New York, NY 10119 Plainview, NY 11803 PH: (212) 239-7711 PH (516) 349=8500 COMPANY: All Bidders PROPOSAL#: CPQ-366190 ATTN: Estimating PAGES: 3 + terms + cuts FROM: Tim Davis TF DATE: Set 16, 2022 PROJECT: SOUTHOLD TOWN HALL REPLACEMENTS We are pleased to provide our confirming quotation for the following Liebert Cooling System(s) CSA listed and labeled with the CSA C/US logo per our standard terms and conditions htti):Htermsconditions.vertivco.com/., The price below is based upon our interpretation of the existing system M#: BU042A-CAM/S#: 378224- 002. No written specifications or drawings provided. Please advise us if revisions are required. Two(2) 11 kW Nominal Liebert PDX Air-Cooled Systems, Model PX011 UA1 CD Units are configured for input voltage of 208 Volts, 3 Phase, 60 Hz • Upflow Air-Cooled System with Front Air Return • Evaporator Type: tilted-slab, copper tubes-aluminum fins with hydrophilic coating • Digital scroll, variable capacity compressor utilizing R-41 OA • Crankcase Heater • Thermal Expansion Valve • Piping exit location out the right side panel of unit • Variable speed EC plug fans • Liebert iCOM Control with High Definition Display • iCOM based communication o Base Comms &Connectivity includes one Ethernet port and one RS-485 port on iCOM controller, dedicated to supporting BACnet IP, Modbus TCP/IP, BACnet 485 , Modbus 485 and SNMP vl/v2c/v3 • Two-Stage 6kW Electric Reheat • Infrared Humidifier • Filter Rating: MERV 8 per ASHRAE 52.2-2007 with One (1) Extra Set of Filters per unit • Locking Disconnect Switch • 65,000 Amp, rms Short Circuit Current Rating • Dual-float condensate pump factory-mounted internal to unit • Supply Air Sensor • Temperature/Humidity Sensors internal for return air sensing • Non-addressable Smoke Sensor • High Temperature Sensor • Three Remote Shut Down Contacts • Four Alarm Contacts • Main Fan Contact • Liquitect Shutdown Contact • Unit Color: RAL 7021 Black Gray Matte • Ship Loose Items (field installed): o LT410 Point Leak-Detection Sensor with External 24 VAC Transformer, quantity one (1) per unit Two(2) Liebert 1-Fan Quiet-Line Air-Cooled MC Microchannel Condensers, Model MCS028E1YD Units are configured for input voltage of 2081230 Volts, 3 Phase, 60 Hz • Outdoor Design Ambient Temperature: 95°F • Microchannel aluminum coil 9/16/2022 Vertiv-Proprietary Page 1 of 8 L - • R-410A factory set points and single refrigerant circuit • Liebert Lee-Temp Kit and factory programmed software for fan control with Lee-Temp o Lee-Temp Kit requires individual input power supply, configured for 208/230 Volts, 1 Phase, 60 Hz • Variable Speed EC Fans • Premium electronic control board providing communication with iCOM using CANbus • Locking Disconnect • Short Circuit Current Rating of 65,000 Amps, rms • Aluminum exterior panels • Epoxy-coated coil with UV topcoat for extended coil life in corrosive environments • Ship Loose Items (field installed): 0 18" high aluminum legs o Liebert Lee-Temp Kits, quantity one (1) per unit Services Include: • 1St Year Parts and Labor Warranty (defined as 12 months from Warranty Inspection or 13 months from Ship Date,whichever occurs first) • 2"d Through 51h Year Compressor Only Extended Warranty • Factory Supervised Warranty Inspection following start-up by installer with installing contractor present during normal business hours M-F. The following items are not included and if required must be supplied by others: • Installation, mechanical or electrical, start-up/commissioning of system/training, maintenance and/or service of any kind, preventative service, point-to-point wiring diagrams,jobsite/hydraulic gate delivery,factory/field witness testing, Rigging, unloading or handling of equipment, Knock- down or cut-down supervision/field service work, labeling, pt-to-pt wiring diagrams/schematics/mapping, PE certifications or engineering. • VFDs, surge suppression, phase loss monitoring, differential pressure switch(es),flow switch(es) • Economizer Coils, Floorstands of any kind, Plenums of any kind • CU Disconnect Switches • Leak detection systems, alternate refrigerants • Auxiliary drain pans, autochange-over/auto-dialer. • Dry contact monitoring panels (ie, RCM4) • Sitescan panels, SiteScan tie-in, spare parts of any kind. • Spring/vibration isolators. • External dampers or motors, special valves (ie pressure independent). • Gauges, insulation, ductwork, fusible plugs, external piping or valves, kindorf, hangers, rails, curbs and/or pads. • Seismic certification. • LEED, UL or ETL certification. Total Price, *FOB factory,freight allowed and prepaid within the continental US, net 30 days subject to credit approval, no tax included, is................................................$ 93,760.00 * Equipment delivered via Non-Teamster driver in a 40' long enclosed truck with no tailgate lift. Current shipping lead-time: 49-52 weeks for indoor PDX units. 78-80 weeks for outdoor MC units. (from acceptance by Vertiv order entry) Subject to change without notice.Please allow 7-10 days for shipping delivery. Quote Expire Date: 10/15/2022 20:00 Vertiv-Proprietary 1 Thank you for your interest in Liebert products and services.We look forward to working with you further on this project. Terms & Conditions: -Quotation Valid for 30 days -Price does not include tax -Terms are Net 30 Days, subject to manufacturer's approval - INFORMATION TO BUYER: This order between the Buyer and Seller is limited to Seller's Terms and Conditions located at http://termsconditions.vertivco.com/ unless a formal agreement governing this Purchase Order/transaction has been executed by the parties, in which case the Terms and Conditions of the signed agreement shall govern. Seller hereby objects to all Buyer's terms and conditions received by Seller and/or issued by Buyer. - Taxes. Any current or future tax, duty, tariff or governmental charge (or increase in same) affecting Seller's costs of production, sale, services or delivery or shipment of Goods Parts, and/or Software, or which Seller is otherwise required to pay or collect in connection with the sale, purchase, delivery, performance, storage, processing, use or consumption of Goods, Parts, ` and/or Software, shall be for Buyer's account and shall be added to the price or billed to Buyer separately, at Seller's election. Raw Materials Escalation Clause. Seller warrants that the prices set forth in the quote are complete and that no additional charge will be added without Buyer's consent, except to the extent that Seller's costs to procure raw materials for the goods increase or decrease (by at least +/- 5% for any such individual raw materials) as compared to such costs listed on the London Metal Exchange (www.ime.com) for such materials at the time of Seller's proposal or quotation, in which case the parties agree that Seller's invoice may adjust prices (up or.down) proportionate to the amount of such increase or decrease for affected raw materials. ALL purchase orders require the following elements for your order to be processed 1) POs are required to be made out to: Vertiv Corporation 1050 Dearborn Drive Columbus, OH 43085 2)ALL PO's require that payment terms of"Net 30 days" be clearly reflected on the PO. 3)ALL PO's require a signature from the issue Vertiv-Proprietary Y Vertiv Corporation warranties that are made by manufacturers and suppliers of such Resale Products. EXCEPT AS TERMS AND CONDITIONS OF SALE SPECIFIED ABOVE, RESALE PRODUCTS FURNISHED HEREUNDER ARE FURNISHED AS-IS, WHERE-IS,WITH NO WARRANTY WHATSOEVER.THE WARRANTY SET FORTH IN THIS SECTION Vertiv Corporation Is herein referred to as the"Seller"and the customer or person or entity purchasing 5 AND THE WARRANTY SET FORTH IN SECTION 8 ARE THE SOLE AND EXCLUSIVE WARRANTIES goods and/or services('Goods")and/or parts required for services("Parts")or licensing software and/or GIVEN BY SELLER WITH RESPECT TO THE GOODS AND/OR SOFTWARE AND ARE IN LIEU OF firmware,which are preloaded,or to be used with Goods("Software")from Seller is referred to as the AND EXCLUDE ALL OTHER WARRANTIES,EXPRESS OR IMPLIED,ARISING BY OPERATION OF "Buyer."These Terns and Conditions,any price list or schedule,quotation,acknowledgment,Seller's LAW OR OTHERWISE,INCLUDING WITHOUT LIMITATION,MERCHANTABILITY AND FITNESS FOR scope or statement of work,or invoice from Seller relevant to the sale of the Goods,Parts and licensing of A PARTICULAR PURPOSE WHETHER OR NOT THE PURPOSE OR USE HAS BEEN DISCLOSED TO Software by Seller,and all associated terms,conditions and documents incorporated by specific reference SELLER IN SPECIFICATIONS, DRAWINGS OR OTHERWISE,AND WHETHER OR NOT SELLER'S herein or therein, constitute the complete and exclusive statement of the terms of the agreement PRODUCTS ARE SPECIFICALLY DESIGNED AND/OR MANUFACTURED BY SELLER FOR BUYER'S ("Agreement")governing the sale of Goods,Parts,and/or license of Software by Seller to Buyer.Any USE OR PURPOSE. SELLER'S WARRANTY EXTENDS ONLY TO PURCHASERS WHO BUY FOR discrepancies between the terms of the above referenced documents shall be resolved by Seller.Seller's INDUSTRIAL OR COMMERCIAL USE.This warranty does not extend to any losses or damages due to acceptance of Buyer's purchase order is expressly conditional on Buyer's assent to all of Seller's terms misuse,accident,abuse,neglect,normal wear and tear,negligence(other than Seller's),unauthorized and conditions of sale,including terms and conditions that are different from or additional to the terms and modification or alteration, use beyond rated capacity, unsuitable power sources or environmental conditions of Buyers purchase order. Buyer's acceptance of.the Goods, Parts, and/or Software will conditions,improper installation,repair,handling,maintenance or application or any other cause not the manifest Buyer's assent to the terms of this Agreement.Seller reserves the right in its sole discretion to fault of Seller. To the extent that Buyer or Its agents have supplied specifications, information, refuse orders. representation of operating conditions or other data to Seller In the selection or design of the Goods and/or Software and the preparation of Sellers quotation,and/or scope of work,and in the event that actual 1.PRICES:Unless otherwise specified in writing by Seller,the price quoted or specified by Seller for the operating conditions or other conditions differ from those represented by Buyer,any warranties or other Goods,Parts and/or Software shall remain In effect for thirty(30)days after the date of Setters quotation, provisions contained herein that are affected by such conditions shall be null and void.Buyer assumes all Seller's scope of work or acknowledgment of Buyer's order for the Goods,whichever occurs first,provided other responsibility for any loss,damage,or Injury to persons or property arising out of,connected with,or an unconditional authorization from Buyer for the shipment or performance of the Goods and/or Parts, resulting from the use of Goods, Parts, and/or Software, either alone or in combination with other and/or Software is received and accepted by Seller within such time period.If such authorization is not products/components. received by Seller within such thirty(30)day period,Seller shall have the right to change the price for the Goods,Parts and/or Software to Sellers price for the Goods,Parts,and/or Software at the time of Seller's 6.LIMITATION OF REMEDY AND LIABILITY:THE SOLE AND EXCLUSIVE REMEDY FOR BREACH shipment or performance thereof.All prices and licensee fees are exclusive of taxes,transportation and OF ANY WARRANTY HEREUNDER(OTHER THAN THE WARRANTY PROVIDED UNDER SECTION 8) insurance,which are to be bome by Buyer.Seller reserves the right to correct any obvious errors in SHALL BE LIMITED TO REPAIR, CORRECTION OR REPLACEMENT, OR REFUND OF THE specifications or prices and,in the event of a force majeure event,make equitable adjustments in Sellers PURCHASE PRICE UNDER SECTION 5.SELLER SHALL NOT BE LIABLE FOR DAMAGES CAUSED price for the Goods,Parts,and/or Software prior to Setters shipment or performance thereof.Unless BY DELAY IN PERFORMANCE AND THE REMEDIES OF BUYER SET FORTH IN THIS AGREEMENT otherwise specified by Seller,Parts that are required for the performance of services will be furnished at ARE EXCLUSIVE. IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF Seller's then-prevailing prices.A service charge of$19.99 will be added to all orders which,excluding ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, shipping charges,taxes,and insurance,do not meet the minimum order value of$750.00.The service OTHER TORT OR OTHERWISE),SHALL SELLER'S LIABILITY TO BUYER AND/OR ITS CUSTOMERS charge amount and/or minimum order value may be changed by Seller at any time,without notice. EXCEED THE PRICE PAID BY BUYER FOR THE SPECIFIC GOODS,PARTS,AND/OR SOFTWARE PROVIDED BY SELLER GIVING RISE TO THE CLAIM OR CAUSE OF ACTION.BUYER AGREES 2.TAXES:Any current or future tax,duty,tariff or governmental charge(or increase in same)affecting THAT SELLER'S LIABILITY TO BUYER AND/OR ITS CUSTOMERS SHALL NOT EXTEND TO INCLUDE Sellers costs of production,sale,services or delivery or shipment of Goods Parts,and/or Software,or INCIDENTAL,CONSEQUENTIAL OR PUNITIVE DAMAGES.The term"consequential damages"shall which Seller is otherwise required to pay or collect in connection with the sale, purchase, delivery, include, but not be limited to, loss of anticipated profits, business interruption, loss of use, revenue, performance,storage, processing,use or consumption of Goods, Parts,and/or Software, shall be for reputation and data,costs incurred,Including without limitation,for capital,fuel,power and toss or damage Buyers account and shall be added to the price or billed to Buyer separately,at Seller's election, to property or equipment.It is expressly understood that any technical advice furnished by Seller with respect to the use of the Goods,Parts and/or Software is given without charge,and Seller assumes no 3.TERMS OF PAYMENT:Unless otherwise specified by Seller,terms are net thirty(30)days from dale of obligation or liability for the advice given,or results obtained,all such advice being given and accepted at Seller's invoice in U.S.currency.Seller shall have the right,among other remedies,either to terminale this Buyer's risk. Agreement or to suspend further performance under this and/or other agreements with Buyer in the event Buyer falls to make any payment when due,which other agreements Buyer and Seller hereby amend 7. INSURANCE: Seller shall maintain the following Insurance or self-Insurance coverage: Workers accordingly.Buyer shall be liable for all expenses,Including attorneys'fees,relating to the collection of Compensation In accordance with the statutory requirements of the stale in which the work is performed. past due amounts.If any payment owed to Seller is not paid when due,it shall bear interest,at a rate to be Employer's Liability with a limit of liability of$2,000,000 per occurrence for bodily injury by accident or determined by Seller,which shall not exceed the maximum rate permitted by law,from the date on which it bodily injury by disease.Commercial General Liability(CGL)for bodily injury and property damage with a Is due until it is paid.Seller may preserve Its Interests in payment by enforcing any applicable mechanic's, limit of$2,000,000 per occurrence and per location aggregate.Automobile Liability Insurance that covers labor,construction or similar lien rights.Should Buyer's financial responsibility become unsatisfactory to usage of all owned,non-owned and leased vehicles and which is subject to a combined single limit per Seller,cash payments or security satisfactory to Seller may be required by Seller for future deliveries or occurrence of$2,000,000.Automobile Liability insurance Includes Contractual Liability,but no special performance of Goods, Parts, and/or Software. If such cash payment or security is not provided, in endorsements.Buyer expressly acknowledges and agrees that Seller has set its prices and entered into addition to Setters other rights and remedies,Seller may discontinue deliveries or performance.Buyer this Agreement in reliance upon the limitations of liability, Insurance coverage, and other terms and hereby grants Seller a security interest in all Goods,Parts,and/or Software sold to Buyer by Seller,which conditions specified herein,which allocate the risk between Seller and Buyer and form a basis of this security interest shall continue until all such Goods,Parts,and/or Software are fully paid for,and Buyer, bargain between the parties. upon Sellers demand,will execute and deliver to Seller such instruments as Seller requests to protect and perfect such security Interest.As permitted by law,all purchases paid by credit card shall be charged a 8.PATENTS AND COPYRIGHTS:Subject to the limitations of the second paragraph of Section 6 and any 2.0%usage surcharge of the Invoice total,for fees paid by Seller to accept credit card transactions. and all associated terms,conditions and documents incorporated by specific reference by Seller,Seller warrants that the Goods and/or Software sold,except as are made specifically for Buyer according to 4.SHIPMENT AND DELIVERY:While Seller will use all reasonable commercial efforts to maintain the Buyer's specifications,do not infringe any valid U.S.patent or copyright in existence as of the date of delivery date(s)and/or performance dates acknowledged or quoted by Seller,all shipping dates and/or shipment.This warranty Is given upon the condition that Buyer promptly notify Seller of any claim or suit performance dates are approximate and not guaranteed. Seller reserves the right to make partial involving Buyer in which such infringement is alleged and cooperate fully with Seller and permit Seller to shipments.Seller,at its option,shall not be bound to lender delivery of any Goods,Parts,and/or Software control completely the defense,settlement or compromise of any such allegation of infringement.Sellers for which Buyer has not provided shipping Instructions and other required information.If the shipment or warranty as to utility patents only applies to infringement arising solely out of Buyer's operation according performance of the Goods,Parts,and/or Software is postponed or delayed by Buyer for any reason,Buyer to Sellers specifications and Instructions of such Goods and/or Software.In the event(1)such Goods agrees to reimburse Seller for any and all storage costs and other additional expenses resulting therefrom. and/or Software are held to infringe such a U.S.patent or copyright in such suit,and the use of such For sales in which the end destination of the Goods,Parts,and/or Software is outside of the United States Goods and/or Software is enjoined,or(ti)a compromise or settlement is made by Seller,Seller shall have (except for those international sales to Seller's affiliated companies),risk of loss and legal title to the the right,at Its option and expense,to procure for Buyer the right to continue using such Goods and/or Goods,Parts,and/or Software shall transfer to Buyer immediately after the Goods,Parts,and/or Software Software,or replace them with non-Infringing Goods and/or Software,or modify same to become non- have passed beyond the territorial limits of the United States.For international sales to Seller's affiliated infringing,or grant Buyer a credit for the depreciated value of such Goods and/or Software and accept companies,all shipments of Goods,Parts,and/or Software are made on a Delivered at Place(DAP)basis, return of them.In the event of the foregoing,Seller may also,at its option,cancel the agreement as to per Incoterms 2020,with freight charges from Seller's facility to destination terminal invoiced to buyer future deliveries of such Goods and/or Software,without liability.Except as otherwise provided herein, either on a Prepaid or PPD/Add basis,as agreed to by Seller and Buyer.All other shipments of Goods, Seller or applicable third party licensor to Seller maintains all right, title and Interest in and to the Parts,and/or Software are made on an Ex Works(EXW)Seller's Shipping Point basis,per Incoterms intellectual property in the Goods,Parts,and/or Software. 2020,with Seller responsible to load goods on Buyers nominated vehicle.Any claims for shortages or damages suffered In transit are the responsibility of Buyer and shall be submitted by Buyer directly to the 9. EXCUSE OF PERFORMANCE: Seller shall not be liable for delays in performance or for non- carrier.Notwithstanding the above,risk of loss and legal title to Parts shall transfer to Buyer(1)upon performance due to acts of God;acts of Buyer;war;viral outbreaks,disease, pandemic,widespread delivery by the Seller,or(it)at the time Parts are placed in storage due to Buyer's delay or postponement. sickness,or epidemic;fire;flood;weather;sabotage;strikes or labor disputes;civil disturbances or riots; Shortages or damages must be identified and signed for at the time of delivery.Requests for changes In governmental requests,restrictions,allocations,laws,regulations,orders or actions;unavailability of or quoted transportation modes will not be made or accepted on orders already processed unless otherwise delays in transportation;unavailability of or delays in the supply of materials,components,parts or labor mutually agreed upon by Seller and Buyer.Requests for changes In quoted transportation modes to required for the design and/or manufacture of Goods,Software or the performance by Seller hereunder; orders already accepted by Seller will be subject to new freight terms and billed at the price in effect at the default of suppliers;or unforeseen circumstances,acts or omissions of Buyer,or any events or causes time of the request for change.Any request for changes to quoted transportation modes must be beyond Sellers reasonable control.Deliveries or other performance may be suspended for an appropriate submitted in writing to Seller and are subject to Sellers acceptance and adjustment in freight price.The period of time or canceled by Seller upon notice to Buyer in the event of any of the foregoing,but the transportation costs quoted by Seller may be changed by Seller without notice in order to reflect Sellers balance of this Agreement shall otherwise remain unaffected as a result of the foregoing. If Seller prices at the time of shipment and will reflect any market increase in transportation costs.If a price for determines that its ability to supply the total demand for the Goods,Parts,and/or Software,or to obtain delivery has been quoted,any changes at the destination for transportation modes,spotting,switching, material used directly or indirectly In the manufacture of the Goods,Parts,and/or Software,is hindered, handling,storage and other accessorial services and demurrage shall be bome by the customer,and any limited or made Impracticable due to causes set forth in this paragraph, Seller may delay or cancel related increase in transportation charges shall be added to the quoted price. performance,make equitable adjustments in Seller's price for the Goods,Parts,and/or Software,and/or allocate its available supply of the Goods,Parts,Software,and/or such material(without obligation to 5. LIMITED WARRANTY: Subject to the limitations of Section 6, Seller's standard warranty that is acquire other supplies of any such Goods,Parts,Software,or material)among its purchasers on such applicable to the Goods and/or Software at the time of purchase is the only warranty applicable to the sale basis as Seller determines to be equitable without liability for any failure of performance which may result of Sellers Goods and/or Software and its terms,conditions and limitations are incorporated by reference therefrom. herein.Seller warrants that it will perform the services as described in these terms and conditions and will exercise all reasonable skill,care and due diligence in the performance of the services.Seller warrants 10.CANCELLATION:Buyer may cancel orders only upon reasonable advance written notice and upon that all services performed shall be free from faulty workmanship for a period of thirty(30)days from payment to Seller of Seller's cancellation charges which Include, among other things, all costs and completion of services.Thermal Solution Components,including but not limited to,fans,air-to-air heal expenses Incurred, and to cover commitments made by the Seller, and a reasonable profit thereon. exchangers, air conditioners, emergency DC vent systems and filtered thermal vent systems are Setters determination of such cancellation charges shall be conclusive. warranted to be free from defects in material and workmanship for a period of twelve(12)months from date of shipment,or manufacturers pass through warranty,whichever Is longer,provided the following 11.CHANGES:Buyer may request changes or additions to the Goods,Parts,and/or Software consistent conditions are met:(i)Semi-annual preventive maintenance logs are maintained by Buyer and such lags with Seller's specifications and criteria.In the event such changes or additions are accepted by Seller, are available to Seller upon request;and(it)Input voltage to the air conditioner unit does not vary by Seller may revise the price,license fees,and dates of delivery and/or performance dates.Seller reserves greater than +/-10%; and (lit) in the event of accidental or Intentional shut-off, a Thermal Solution the right to change designs and specifications for the Goods,Parts,and/or Software without prior notice to Component will not be restarted for at least five(5)minutes;and(iv)the refrigerant specified on the unit Buyer,except with respect to Goods,Parts,and/or Software being made to order for Buyer.Seller shall nameplate label will be the only refrigerant utilized In the air conditioner unit;and,(v)Buyer complies with have no obligation to Install or make such change in any Goods,Parts,and/or Software manufactured all Installation,operations and maintenance instructions provided by Seller.Goods,Parts and/or Software prior to the date of such change. purchased by Seller from a third party for resale or license to Buyer("Resale Products")shall carry only the warranty extended by the original manufacturer.To the extent assignable,Seller assigns to Buyer any Vertiv Terms and Conditions,August 2021 SL-70604 REVD_8-21 1' r 12.NUCLEARIMEDICAL:GOODS, PARTS,AND SOFTWARE SOLD HEREUNDER ARE NOT FOR Seller unless made In writing and signed on its behalf by a duly authorized representative of Seller.No USE IN CONNECTION WITH ANY NUCLEAR, MEDICAL, LIFE-SUPPORT AND RELATED conditions,usage of trade,course of dealing or performance,understanding or agreement purporting to APPLICATIONS.Buyer accepts Goods,Parts,and Software with the foregoing understanding,agrees to modify,vary,explain,or supplement this Agreement shall be binding unless hereafter made In writing and communicate the same in writing to any subsequent purchasers or users and to defend,indemnify and signed by the party to be bound, and no modification or additional terms shall be applicable to this hold harmless Seller from any claims, losses,sults,judgments and damages,including incidental and Agreement by Seller's receipt,acknowledgment,or acceptance of purchase orders,shipping Instruction consequential damages,arising from such use,whether the cause of action be based in tort,contract or forms,or other documentation containing terms at variance with or in addition to those set forth herein. otherwise,including allegations that the Sellers liability is based on negligence or strict liability. Any such modifications or additional terms are specifically rejected and deemed a material alteration hereof.If this document shall be deemed an acceptance of a prior offer by Buyer,such acceptance is 13.ASSIGNMENT:Buyer shall not assign its rights or delegate Its duties hereunder or any Interest herein expressly conditional upon Buyer's assent to any additional or different terms set forth herein.Seller without the prior written consent of Seller,and any such assignment,without such consent,shall be void. reserves the right to subcontract services to others.No waiver by either party with respect to any breach or default or of any right or remedy,and no course of dealing,shall be deemed to constitute a continuing 14.SOFTWARE:Notwithstanding any other provision herein to the contrary,Seller or applicable third waiver of any other breach or default or of any other right or remedy,unless such waiver be expressed in party licensor to Seller shall retain all rights of ownership and title in its respective Software,including writing and signed by the party to be bound.All typographical or clerical errors made by Seiler in any without limitation all rights of ownership and title in its respective copies of such Software. Except as quotation,acknowledgment or publication are subject to correction.The validity, performance,and all otherwise provided herein,Buyer is hereby granted a nonexclusive,non-transferable royalty free license to other matters relating to the interpretation and effect of this Agreement shall be governed by the law of the use the Software Incorporated Into the Goods solely for purposes of Buyer properly utilizing such Goods state of Ohio without regard to its conflict of laws principles.Buyer and Seller agree that the proper venue purchased from Seller.All other Software shall be furnished to,and used by,Buyer only after execution of for all actions arising in connection herewith shall be only in Ohio and the parties agree to submit to such Seller's(or the licensor's)applicable standard license agreement,the terms of which are incorporated jurisdiction.No action,regardless of form,arising out of transactions relating to this contract,may be herein by reference. brought by either party more than two (2)years after the cause of action has accrued. The U.N. Convention on Contracts for the International Sales of Goods shall not apply to this agreement. 15.TOOLING:Tool,die,and pattern charges,if any,are in addition to the price of the Goods and are due and payable upon completion of the tooling.All such tools,dies and patterns shall be and remain the 25.DATA COLLECTION AND USE:By using the Goods,Parts and/or Software,Buyer grants Seller,Its property of Seller.Charges for tools,dies,and patterns do not convey to Buyer,title,ownership interest In, affiliates,subsidiaries,and service providers,a non-exclusive,irrevocable,royalty free,worldwide right or rights to possession or removal,or prevent their use by Seller for other purchasers,except as otherwise and license to collect,compile,retain,use,reproduce,and create derivative works of,your non-personal expressly provided by Seller and Buyer in writing with reference to this provision. information and data,which includes without limitation,all data,materials,reports,text,sound,video, image files,software or any other information("Service Data")that is provided by,or on behalf of,Buyer, 16. DOCUMENTATION: Seller shall provide Buyer with that data/documentation which is specifically or collected or compiled by Seller,its affiliates,subsidiaries,or service providers through the Goods.Parts, Identified in Sellers quotation.If additional copies of data/documentation are to be provided by Seller,it and/or Software.Seller,its affiliates,subsidiaries,and service providers may collect,compile,retain,use, shall be provided to Buyer at Sellers applicable prices then in effect. reproduce,and create derivative works of Service Data:(i)to provide services,support,and maintenance; (ii)to develop and improve products,software,and services;and(iii)for scientific and technical research 17.INSPECTIONfTESTING:Buyer,at its option and expense,may observe the Inspection and testing by and marketing purposes.Buyer is solely responsible for the Service Data,and Buyer will secure and Seller of the Goods and/or Software for compliance with Sellers standard test procedures prior to maintain all rights necessary for Seller,its affiliates,subsidiaries,and service providers to process and use shipment,which inspection and testing shall be conducted at Sellers plant at such reasonable time as is Service Data as described in this paragraph without violating the rights of any third party or otherwise, specified by Seller.Any rejection of the Goods and/or Software must be made promptly by Buyer before obligating Seller,its affiliates,subsidiaries,and service providers to Buyer or any third party.The Service shipment.Tests shall be deemed to be satisfactorily completed and the test fully met when the Goods Data will be aggregated with other information,materials,or data collected or compiled by,or provided to, and/or Software meet Sellers criteria for such procedures.If Buyer does not Inspect the Goods and/or Seller,Its affiliates,subsidiaries,or service providers and anonymized,such that the Service Data will not Software at Sellers plant as provided herein,Buyer shall have ten(10)days from(1)the date of delivery of intentionally reveal Buyer's identity.In accordance with applicable law,Service Data may be transferred, Goods,Parts,and/or Software and(ii)from the date of completion of each portion of the services to transmitted,or distributed to,stored,and processed in,cloud computing environments in the United States inspect the Goods,Parts,and/or Software,and in the event of any non-conformity,Buyer must give written or any other country in which Seller,its affiliates,subsidiaries,or service providers maintain operations.By notice to Seller within said period stating why the Goods,Parts,and/or Software are not conforming, using the Goods.Parts,and/or Software,Buyer agrees to such use,transfer,transmission,distribution, Failure by Buyer to give such notice constitutes unqualified acceptance of the Goods, Parts, and/or storage,and processing of the Service Data.Seller,its affiliates,subsidiaries,and service providers will Software. Buyer's sole remedy for non-conforming services shall be correct performance of services retain Service Data for as long as is necessary for Seller and its affiliates and subsidiaries business incorrectly performed by Seller. purposes in accordance with applicable law.The rights and licenses granted herein to Sellers service providers shall only be granted to the extent service providers are providing goods and services on 18.RETURNED GOODS:Advance written permission to return Goods,Parts,and/or Software must be Seller's and its affiliates and subsidiaries behalf. obtained from Seller in accordance with Seller's then current Return Material Authorization (RMA) procedures and a return authorization number issued.Such Goods,Parts,and/or Software must be(i) 26.PRIVACY:Seller will collect and process personal data of those employed by or otherwise affiliated current,unused,catalogued Goods,Parts,and/or Software,still in original packaging(it)free of all liens, with Buyer in accordance with Sellers"Privacy Notice for Customers and Suppliers—California"available encumbrances,or other claims,and(ill)shipped,transportation prepaid,to Seller's specified location, here www.vertiv.com/ca-privacy(the "Notice"), which Notice the Buyer hereby acknowledges having Returns made without proper written permission will not be accepted by Seller.Seller reserves the right to received,read,and understood.In the event of any queries or concerns with its contents,Buyer must inspect Goods,Parts,and/or Software prior to authorizing return, contact Seller at the contact details provided in the Notice prior to entering into this Agreement or the commencement of performance hereunder,in failure of which,the terms of the Notice will be deemed 19.BILLABLE SERVICES:Additional charges will be billed to Buyer at Seller's then prevailing labor rales accepted and consented to in their entirety. and Parts prices for any of the following:a)any services not specified in Seller's quotation,Seller's order acknowledgement,Seller's scope of work,or other documents referenced herein and therein;b)any 27.ADDITIONAL SERVICE CONDITIONS:The Buyer shall furnish to Seller,at no cost,suitable working services performed at times other than Seller's normal service hours;c)if timely and reasonable site space,storage space,adequate heat,telephone,light,ventilation,regulated electric power and oudets for and/or equipment access is denied the Seller service representative;d)if it is necessary,due to local testing purposes.The facilities shall be within a reasonable distance from where the Goods are to be circumstances, to use union labor or hire an outside contractor,Seller service personnel will provide provided.Seller and its representatives shall have full and free access to the equipment in order to provide supervision only and the cost of such union or contract labor will be charged to Buyer;(e)if service or the necessary Goods.Buyer authorizes Seller to send a service technician or an authorized agent to repair is necessary to return equipment to proper operating condition as a result of other than Seller(I) access any site requested by Buyer to perform services,including services on different scopes of work maintenance, repair, or modification (Including, without limitation, changes in specifications or and equipment as requested by Buyer.Buyer shall provide the means to shut-off and secure electric incorporation of attachments or other features),(ii)misuse or neglect,(including,without limitation,failure power to the equipment and provide safe working conditions.Seller is under no obligation to remove or to maintain facilities and equipment in a reasonable manner), (III) failure to operate equipment In dispose of Parts or equipment unless specifically agreed upon in Seller's scope of work.Buyer shall accordance with applicable specifications,and(iv)catastrophe,accident, or other causes external to Immediately Inform Seller,in writing, at the time of order placement and thereafter,of any unsafe or equipment;(f)Seller's performance is made more burdensome or costly as a result of Buyer's failure to hazardous substance or condition at the site,including,but not limited to,the presence of asbestos or comply with its obligations herein,or(g)any additional obligations or requirements,including but not asbestos-containing materials,and shall provide Seller with any applicable Material Data Safety Sheets limited to those related to Insurance requirements,service delivery,building entry or technical training. regarding the same.Any losses,costs,damages,claims and expenses Incurred by Seller as a result of Buyer's failure to so advise Seller shall be bome by Buyer.Seller,In its sole discretion and without cost or 20.DRAWINGS:Sellers documentation,prints and drawings(including without limitation,the underlying penalty,reserves the right to cancel its performance under this Agreement or any order immediately upon technology)furnished by Seller to Buyer In connection with this Agreement are the property of Seller and written notice to Buyer following Seller discovery of unsafe or hazardous site substance or condition or any Seller retains all rights,Including without limitation,exclusive rights of use,licensing and sale.Possession other circumstance altering Seller's performance hereunder.Buyer shall appoint a representative familiar of such prints or drawings does not convey to Buyer any rights or license,and Buyer shall return all copies with the site and the nature of Seller's performance to be accessible at all times that Seller personnel are (in whatever medium) of such prints or drawings to Seller immediately upon request therefor. at the site. Seller shall not be liable for any expenses incurred by Buyer in removing, replacing or Notwithstanding the foregoing,Buyer may use the documentation,prints and drawings In connection with refurbishing any Buyer equipment or any part of Buyers building structure that restricts Seller access. the use of the Goods,Parts,and/or Software. Buyer personnel shall cooperate with and provide all necessary assistance to Seller.Seller shall not be liable or responsible for any work performed by Buyer. 21.BUYER SUPPLIED DATA:To the extent that Seller has been provided by,or on behalf of,Buyer any specifications,description of operating conditions or other data and information in connection with the 28.INDEMNITY:Each party shall indemnify and hold the other party harmless from loss,damage,liability selection or design of the Goods,Parts,and/or Software,and/or the provision of services,and the actual or expense resulting from damage to personal property of a third party,or injuries,including death,to third operating conditions or other circumstances differ from those provided by Buyer and relied upon by Seller, parties to the extent caused by a negligent act or omission of the party providing Indemnification or that any warranties or other provisions contained herein which are affected by such conditions shall be null and party's subcontractors, agents or employees during performance of services hereunder. Such void. indemnification shall be reduced to the extent damage or injuries are attributable to others and in no event shall the Indemnifying party be obligated to Indemnify or insure the other party for the Indemnitee's own 22.EXPORT/IMPORT:Buyer agrees that all applicable import and export control laws,regulations,orders fault or negligence.The indemnifying party shall defend the other party in accordance with and to the and requirements,including without limitation those of the United States and the European Union,and the extent of the above indemnification,provided that the indemnifying party Is:i)promptly notified by the jurisdictions In which the Seller and Buyer are established or from which Goods,Parts,Software,and other party, in writing, of any claims, demands or suits for such damages or injuries; it) given all services may be supplied,will apply to their receipt and use.In no event shall Buyer use,transfer,release, reasonable Information and assistance by the other party; iii) given full control over any resulting import, export, Goods, Parts, or Software in violation of such applicable laws, regulations, orders or negotiation, arbitration or litigation, including the right to choose counsel and settle claims, or the requirements. Indemnifying party's obligations herein shall be deemed waived. 23.NON-SOLICITATION:Buyer shall not solicit,directly or indirectly,or employ any employee of Seller COPYRIGHT 2021 Vertiv Group Corp.All rights reserved.VertivT"'and the Vertiv logo are trademarks or during the period any Goods are being provided to Buyer and for a period of one(1)year after the last registered trademarks of Vertiv Group Corp.All other names and logos referred to are trade names, provision of Goods, trademarks or registered trademarks of their respective owners.While every precaution has been taken to ensure accuracy and completeness here,Vertiv Group Corp.assumes no responsibility,and disclaims all 24.GENERAL PROVISIONS:This Agreement supersedes all other communications,negotiations and liability,for damages resulting from use of this Information or for any errors or omissions.Specifications, prior oral or written statements regarding the subject matter of this Agreement.No change,modification, rebates and other promotional offers are subject to change at Vertiv's sole discretion upon notice. rescission,discharge,abandonment,or waiver of these terms and conditions shall be binding upon the Vertiv Terms and Conditions,August 2021 SL-70604—REVD_8-21 .y, LIMITED WARRANTY FOR INTELLISLOT INTERFACE CARDS,LEAK DETECTION PRODUCTS,STANDALONE MONITORING PRODUCTS, RACK MONITORING PRODUCTS,AND AUTOMATED SHUTDOWN PRODUCTS Warrantor: Vertiv Corporation (referred to herein as ("Vertiv") offers the following One Year Limited Warranty Against Defects in Material and Workmanship ("Warranty")for applicable Product. Products Covered: •IntelliSlot Interface Cards . •Leak Detection Products •Standalone Monitoring Panels •Rack Monitoring Products •Automated Shutdown Products Terms of Limited Warranty: As provided herein,Vertiv warrants that during the Warranty Period(as defined below): •is free of defects in material and workmanship;and •conforms to the descriptions contained in any applicable certified drawings for such Product,to Vertiv's final invoices,and to applicable Vertiv Product brochures and manuals current as of the date of Product shipment("Descriptions") Warranty Period: A period of thirteen(13)months from date of product shipment. Product shipment date is determined only from the bill of lading.If any part or portion of the Vertiv Product fails to conform to the Warranty within the Warranty Period, Vertiv, at its option, will furnish new or factory remanufactured Products for repair or replacement of that failed portion or part.REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT OR PART THEREOF DOES NOT EXTEND OR RESTART THE ORIGINAL WARRANTY PERIOD.Vertiv does not control the use of any Product and, accordingly,materials classified as"Descriptions"are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. Who is Covered: This Warranty extends to the original end-user(the "User') and only within the fifty states of the USA and.Canada. This Warranty is not transferable or assignable without the prior written permission of Vertiv.This Warranty is given ONLY to purchasers who buy for commercial or industrial use in the ordinary course of business.Vertiv assigns to User any warranties which are made by manufacturers and suppliers of components of, or accessories to, the Vertiv Product and which are assignable, but Vertiv makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties, assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components or accessories. Warranty Claims Procedure and Services: Within thirty(30)days after Users discovery of a defect, User must contact their local Vertiv representative and provide all material information relating to such alleged defect. User may contact Vertiv at (800) 543-2378 for local Vertiv representative information. Vertiv, in its sole discretion, shall either repair or replace defective Products. User shall bear all labor or shipping charges associated with de-installation, shipment and transportation of the returned Product and the transportation and installation of the Product replaced under warranty.Warranty coverage will be extended only after Vertiv or its representative's inspection discloses the claimed defect and shows no signs of treatment or use that would void the coverage of this Warranty.All defective Products and parts thereof replaced under this Warranty become the property of Vertiv. Items Not Covered: THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse, improper application,wrong or inadequate electrical current or connection, negligence, inappropriate on site operating conditions, repair by non-Vertiv designated personnel, accident in transit, tampering, alterations, a change in location or operating use, exposure to the elements,Acts of God, theft or installation contrary to Vertiv's recommendations or specifications,or in any event if the Vertiv serial number has been altered,defaced,or removed. THIS WARRANTY DOES NOT COVER unauthorized shipping costs, Product installation/removal costs,travel costs,external circuit breaker resetting or maintenance or service items and further, except as may be provided herein, does NOT include labor costs or transportation, arising from the replacement of the Vertiv Product or any part thereof or charges to remove or reinstall same at any premises of User,nor for site inspections that determine no corrective action was required nor any other services not expressly provided for by the terms of the Warranty.Consumables,including but not limited to air filters,are not covered by this Warranty. THIS WARRANTY IS VOID UPON THE FOLLOWING: (1) the Product having been stored in an unsuitable environment after Product shipment,and/or(2)if the Product contains an internal battery, User allows such battery to discharge below the minimum battery voltage cutoff point or if the User does not start recharging a discharged,or partially discharged,battery within forty-eight(48)hours of the discharge period. No salesperson, employee or agent of Vertiv is authorized to add to or vary the terms of this Warranty. Vertiv retains the right to cancel the Warranty, subject to reinstatement at Vertiv's sole discretion, for late-or non-payment of the Product purchase price and any other amounts due. Warranty terms may only be modified,if at all,if in writing and signed by a Vertiv officer. Other Limitations: THIS LIMITED WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. USER'S SOLE AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE VERTIV PRODUCT AS SET FORTH HEREIN. IF USER'S REMEDY IS DEEMED TO FAIL OF ITS ESSENTIAL PURPOSE BY A COURT OF COMPETENT JURISDICTION,VERTIV'S RESPONSIBILITY FOR PROPERTY LOSS OR DAMAGE SHALL NOT EXCEED THE NET PRODUCT PURCHASE PRICE. IN NO EVENT SHALL VERTIV ASSUME ANY LIABILITY FOR INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES OF ANY KIND WHATSOEVER, INCLUDING WITHOUT LIMITATION LOST PROFITS, BUSINESS INTERRUPTION OR LOSS OF DATA,WHETHER ANY CLAIM IS BASED UPON THEORIES OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, TORT, OR OTHERWISE. THE PRODUCTS LISTED IN THIS WARRANTY ARE NOT FOR USE IN CONNECTION WITH ANY NUCLEAR,MEDICAL,LIFE-SUPPORT AND RELATED APPLICATIONS. 590-2023-501A/SL-04900 8-18 OPTIONAL LIMITED WARRANTY FOR THERMAL MANAGEMENT PRODUCTS Warrantor:Vertiv Corporation (referred to herein as"Vertiv") offers the following Optional Limited Warranty Against Defects in Material and Workmanship ("Warranty")for applicable Product. Products Covered: •Compressors contained in Liebert Thermal Management Products Terms of Limited Warranty: As provided herein,Vertiv warrants that during the Warranty Period(as defined below)the Product: •is free of defects in material and workmanship;and •conforms to the descriptions contained in any applicable certified drawings for such Product,to Vertiv's final invoices,and to applicable Vertiv Product brochures and manuals current as of the date of Product shipment("Descriptions") Warranty Period: A period of U one ,(__) two U three(_) four years after the expiratiori of the One Year Limited Warranty Against Defects in Materia land Workmanship. If any part or portion of the Vertiv Product fails to conform to the Warranty within the Warranty Period,Vertiv,at its option,will furnish new or factory remanufactured Products for repair or replacement of that failed portion or part. REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT OR PART THEREOF DOES NOT EXTEND OR RESTART THE ORIGINAL WARRANTY PERIOD.Vertiv does not control the use of any Product and, accordingly, materials classified as "Descriptions" are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. Who is Covered:' This Warranty extends to the original end-user(the"User")and only within the fifty states of the USA and,Canada. This Warranty is not transferable or assignable without the prior written permission of Vertiv.This Warranty is given ONLY to purchasers who buy for commercial or industrial use in the ordinary course of business.Vertiv assigns to User any warranties which are made by manufacturers and suppliers of components of, or accessories to, the Vertiv Product and which are assignable, but Vertiv makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties,assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers / or suppliers and extends no coverage under this Warranty to such components or accessories. Warranty Claims Procedure and Services: Within thirty (30) days after User's discovery of a defect, User must contact their local Vertiv representative and provide all material information relating to such alleged defect.User may contact Vertiv at(800)543-2378 for local Vertiv representative information. Vertiv,in its sole discretion,shall either repair or replace defective Products.User shall bear all labor or shipping charges associated with de- installation, shipment and transportation of the returned Product and the transportation and installation of the Product replaced under warranty.Warranty coverage will be extended only after Vertiv or its representative's inspection discloses the claimed defect and shows no signs of treatment or use that would void the coverage of this Warranty.All defective Products and parts thereof replaced under this Warranty become the property of Vertiv. Items Not Covered: THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse,improper application,wrong or inadequate electrical current or connection, inadequate water or drain services, negligence, inappropriate on site operating conditions, repair by non-Vertiv designated personnel, accident in transit, tampering, alterations, a change in location or operating use, exposure to the elements,Acts of God,theft or installation contrary to Vertiv's recommendations or specifications,or in any event if the Vertiv serial number has been altered, defaced,or removed. THIS WARRANTY DOES NOT COVER shipping costs, Product installation/removal costs, travel costs, external circuit breaker resetting, loss of refrigerant, maintenance or service items and further, except as may be provided herein, does NOT include labor costs or transportation, arising from the replacement of the Vertiv Product or any part thereof or charges to remove or reinstall same at any premises of User,nor for site inspections that determine no corrective action'was required nor any other services not expressly provided for by the terms of the Warranty. Consumables, including but not limited to air filters,are not covered by this Warranty. Non-compressor related parts are warranted separately. THIS WARRANTY IS VOID UPON THE FOLLOWING: (1) the Product having been stored in an unsuitable environment after Product shipment and/or (2) if applicable, Product warranty inspection performed by a third party other than.Vertiv and/or its authorized representatives.No salesperson,employee or agent of Vertiv is authorized to add to or vary the terms of this Warranty.Vertiv retains the right to cancel the Warranty,subject to reinstatement at Vertiv's sole discretion,for late-or non-payment of the Product purchase price and any other amounts due. Warranty terms may only be modified,if at all,if in writing and signed by a Vertiv officer. Other Limitations: THIS LIMITED WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. USER'S SOLE AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE VERTIV PRODUCT AS SET FORTH HEREIN,IF USER'S REMEDY IS DEEMED TO FAIL OF ITS ESSENTIAL PURPOSE BY A COURT OF COMPETENT JURISDICTION, VERTIV'S RESPONSIBILITY FOR PROPERTY LOSS OR DAMAGE SHALL NOT EXCEED THE NET PRODUCT PURCHASE PRICE. IN NO EVENT SHALL VERTIV ASSUME ANY LIABILITY FOR INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES OF ANY KIND WHATSOEVER, INCLUDING WITHOUT LIMITATION LOST PROFITS, BUSINESS INTERRUPTION OR LOSS OF DATA,WHETHER ANY CLAIM IS BASED UPON THEORIES OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, TORT, OR OTHERWISE. THE PRODUCTS LISTED IN THIS WARRANTY ARE NOT FOR USE IN CONNECTION WITH ANY NUCLEAR,MED 590-2004-501A/SL-020008-18 n ,Y r LIMITED WARRANTY FOR THERMAL MANAGEMENT PRODUCTS Warrantor: Vertiv Corporation (referred to herein as "Vertiv") offers the following One-Year Limited Warranty Against Defects in Material and Workmanship("Warranty")for applicable Product. Products Covered: •Vertiv Thermal Management Products Terms of Limited Warranty: As provided herein,Vertiv warrants that during the Warranty Period(as defined below)the Product: •is free of defects in material and workmanship;and •conforms to the descriptions contained in any applicable certified drawings for such Product,to Vertiv's final invoices,and to applicable Vertiv Product brochures and manuals current as of the date of Product shipment("Descriptions") Warranty Period: A period of one (1) year from a valid, documented Product warranty inspection performed by Vertiv personnel, which period shall expire no later than eighteen (18)months from the Product shipment date. Product shipment date is determined only from the bill of lading. If Product warranty inspection is not performed,the Warranty Period is thirteen(13)months from the date of shipment by the original end-user. If any part or portion of the Vertiv Product fails to conform to the Warranty within the Warranty Period, Vertiv, at its option, will furnish new or factory remanufactured Products for repair or replacement of that failed portion or part.REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT OR PART THEREOF DOES NOT EXTEND OR RESTART THE ORIGINAL WARRANTY PERIOD.Vertiv does not control the use of any Product and,accordingly, materials classified as "Descriptions" are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. Who is Covered This Warranty extends to the original end-user(the"User")and only within the fifty states of the USA and Canada.This Warranty is not transferable or assignable without the prior written permission of Vertiv. This Warranty is given ONLY to purchasers who buy for commercial or industrial use in the ordinary course of business.Vertiv assigns to User any warranties which are made by manufacturers and suppliers of components of,or accessories to, the Vertiv Product and which are assignable, but Vertiv makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties, assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components or accessories. Warranty Claims Procedure and Services: Within thirty(30)days after User's discovery of a defect,User must contact their local Vertiv representative and provide all material information relating to such alleged defect.User may contact Vertiv at(800)543-2378 for local Vertiv representative information. Vertiv,in its sole discretion,shall either repair or replace defective Products. User shall bear all labor or shipping charges associated with de-installation, shipment and transportation of the returned Product and the transportation and installation of the Product replaced under warranty.Warranty coverage will be extended only after Vertiv or its representative's inspection discloses the claimed defect and shows no signs of treatment or use that would void the coverage of this Warranty.All defective Products and parts thereof replaced under this Warranty become the property of Vertiv. Items Not Covered: THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse, improper application, wrong or inadequate electrical current or connection, inadequate water or drain services, negligence, inappropriate on site operating conditions, repair by non-Vertiv designated personnel, accident in transit,tampering, alterations, a change in location or operating use, exposure to the elements, Acts of God,theft or installation contrary to Vertiv's recommendations or specifications,or in any event if the Vertiv serial number has been altered,defaced,or removed. THIS WARRANTY DOES NOT COVER shipping costs, Product installation/removal costs, travel costs, external circuit breaker resetting, loss of refrigerant,maintenance or service items and further,except as may be provided herein,does NOT include labor costs or transportation,arising from the replacement of the Vertiv Product or any part thereof or charges to remove or reinstall same at any premises of User, nor for site inspections that determine no corrective action was required nor any other services not expressly provided for by the terms of the Warranty. Consumables, including but not limited to air filters,are not covered by this Warranty. THIS WARRANTY IS VOID UPON THE FOLLOWING:(1)the Product having been stored in an unsuitable environment after Product shipment and/or(2) if applicable,Product warranty inspection performed by a third party other than Vertiv and/or its authorized representatives.No salesperson,employee or agent of Vertiv is authorized to add to or vary the terms of this Warranty.Vertiv retains the right to cancel the Warranty,subject to reinstatement at Vertiv's sole discretion,for late-or non-payment of the Product purchase price and any other amounts due.Warranty terms-may only be modified, if at all, if in writing and signed by a Vertiv officer. Other Limitations THIS LIMITED WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES,EXPRESS OR IMPLIED,INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. USER'S SOLE AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE VERTIV PRODUCT AS SET FORTH HEREIN. IF USER'S REMEDY IS DEEMED TO FAIL OF ITS ESSENTIAL PURPOSE BY A COURT OF COMPETENT JURISDICTION, VERTIV'S RESPONSIBILITY FOR PROPERTY LOSS OR DAMAGE SHALL NOT EXCEED THE NET PRODUCT PURCHASE PRICE. IN NO EVENT SHALL VERTIV ASSUME ANY LIABILITY FOR INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES OF ANY KIND WHATSOEVER, INCLUDING WITHOUT LIMITATION LOST PROFITS, BUSINESS INTERRUPTION OR LOSS OF DATA, WHETHER ANY CLAIM IS BASED UPON THEORIES OF CONTRACT, NEGLIGENCE, STRICT LIABILITY,, TORT, OR OTHERWISE. THE PRODUCTS LISTED IN THIS WARRANTY ARE NOT FOR USE IN CONNECTION WITH ANY NUCLEAR,MEDICAL,LIFE-SUPPORT AND RELATED APPLICATIONS. 590-2001-5018/SL-01000 9-19 Document generated 16 September 2022 03:00 PM (EST). vERTiv LIEBERT PDX STANDARD FEATURES AIR COOLED DX COOLING COIL The evaporator coil is constructed of copper tubes and hydrophilic coated aluminum fins.A stainless steel condensate drain pan is provided. REFRIGERATION SYSTEM Single refrigeration circuit shall include a liquid line filter drier,a refrigerant sight glass with moisture indicator, an expansion valve,pressure safety switch, and a liquid line solenoid valve. DIGITAL SCROLL COMPRESSOR The compressor is an R-41 OA scroll-type with variable capacity operation from 20-100%. Compressor solenoid valve unloads the compressor to provide variable capacity operation.The compressor has a suction gas cooled motor, EPDM vibration isolators, internal thermal overloads,automatic reset high pressure switch with lockout after three failure occurrences, RotoLock service valves,low pressure transducer and crankcase heater. ELECTRONICALLY COMMUTATED(EC)FAN is plug type,integral direct driven fan with backward curved blades and Electronically Commutated DC motor;commonly referred to as an EC fan.The fan speed shall be variable and automatically regulated by the Liebert iCOMO control through all modes of operation.The impeller shall be made of aluminum and dynamically balanced.The fan shall be located to draw air through the coil to ensure even air distribution and maximum coil performance. CABINET The exterior panels are 20 gauge steel and powder coated with RAL7021 black gray matte color paint to protect against corrosion. Exterior panels are insulated with 1/2"(sides)or 1"(front and rear), 1-1/2 Ib insulation. Front and side panels have captive, 1/4 turn fasteners to allow quick panel removal.The cabinet is designed so that all components are serviceable and removable using the front and right sides of the unit. , FILTER-The filter shall be deep-pleated,2 in(51 mm)thick with a MERV8 rating efficiency based on ASHRAE 52.2-2007. LIEBERT iCOM CONTROL SYSTEM The Liebert PDX is controlled by the iCOM Control System. A 7-inch,high definition, capacitive,color touchscreen presents system information and allows parameters to be viewed and adjusted. The controls shall be menu driven and shall display user menus for active alarms,event log,graphic data, unit view/status overview(including the monitoring of room conditions,operational status in percentage of each function,date and time),total run hours,various sensors, display setup and service contacts. It features a 3-level password protection system. Unit—to-Unit communication capability with other Liebert PDX units is included as standard. BASE-COMMS FOR BMS CONNECTIVITY The Liebert iCOM controller provides one Ethernet Port and one RS-485 Port dedicated for BMS connectivity. Provides ground fault isolated RS-485 Modbus, BACnet IP &Modbus IP network connectivity to Building Management Systems,for unit monitoring and management. Also, provides ground fault isolated 10/100 baseT Ethernet connectivity for unit monitoring and management. The supported management interfaces include:SNMP v1/v2c/v3 for Network Management Systems, HTTP for web page viewing,SMTP for e-mail, and SMS for mobile messaging. The iCOM controller can support dual IP on one network and one 485 protocol simultaneously. UNIT DISCONNECT SWITCH A"Locking-Type"fused disconnect switch is available.The"Locking-Type"consists of a main unit switch operational from the outside of the unit. Access to the high voltage electric panel can be obtained only with the switch in the "off"position.The disconnect has main fuses within the disconnect. 65,000 AMP SHORT CIRCUIT CURRENT RATING(SCCR)The 60Hz electrical panel provides 65kA SCCR. REMOTE SHUTDOWN TERMINAL The remote shutdown terminal shall provide the customer with a location to remotely shut down the unit,complying with the National Fire Code. DPNO03380 REV: 5 Z Page:1/2 REV DATE: 9/18 Document generated 16 September 2022 03:00 PM (EST). A VERTIV LIEBERT PDX STANDARD FEATURES AIR COOLED COMMON ALARM CONTACT The common alarm contacts shall provide the customer with a set of normally open contacts for remote indication of unit alarms. Four alarm contacts shall be provided for units without a condensate pump. Three alarm contacts shall be provided for units with a condensate pump. SUPPLY AIR SENSOR The supply air temperature sensor shall provide real-time,direct feedback to the downflow raised floor cooling unit to provide a consistent supply air temperature by adjusting the compressor capacity or the chilled water valve accordingly to maintain set point. The supply air temperature sensor will provide real-time, monitoring of discharge air temperature on all other units. INFRARED HUMIDIFIER High intensity infrared quartz lamps over a stainless steel humidifier pan.An automatic water supply system maintains water level in the pan and a timed flush system greatly reduces mineral precipitation,and is field adjustable to change the cycle time. A 1"(25mm)air-gap within the water supply piping assembly shall prevent backflow of the humidifier supply water. ELECTRIC REHEAT Electric low watt density 304/304 stainless steel fin tubular electric reheat elements provide reheat to control room dry bulb temperature. s g DPNO03380 REV: 5 Page:2/2 REV DATE: 9/18 uE �^ Document generated 16 September 2U2303:0DIPM (EST). r — — � N���������� ������ ��������N�� ��N�������� U ������ � u�m� m m nn. ' OPTIONAL FEATURES ^���� COOLED �����K ���� ��u�n ��v�v����� (Refer tOspecification sheet for options supplied) STEAM GENERATING HUM|D.IFIERisfactory-in stalied ill the 000|ing unit and is operated bythe Lieber-tiCOMcontrol system. It is complete with disposable cylinder,all Supply and dfain valves, steam distributor and electronic controls,The need to change the canister is indiu8l,ed On the Li:bediC0M display.The humidifier is designed to operate with water conductivity from 330-670(0OHz) 0iu0&fcOn. System 8Uknn}aUoa||y hl|u and drains aSweU as maintains the required water level based on conductivity.A 1`(25(nm)air- gap within the ir-gapw8Moth8 humidifier assembly nl'GUprevent backflow oUthe humidifier supply water. SCR REHEAT s a 61,.w electric re�ea', clement controlled by a variabLe ouiput Silicon Cnntn}|}od Rectifier/SCR> control. The SCR reheat option provides Precise temperoturecontrol. PX811mndgbonly, DUAL-FLOAT CONDENSATE PUMP has a capacity of 5 GPM (118.9 l/min)at 40ft(12.2 m) head. Pump is complete with integral primary and secondary float sw|VCh8S'pump, motor assembly and reservoir.The secondary float shall send osignal tothe|oou|alarm and shut down the unit upon high water condition.The condensate pump shall be facto ry-i ristalled on upflow units and field-installed on dmwnUmwun|tu. DIGITAL SCROLL COMPRESSOR SOUND JACKET The compressor sound jacket shall r8dVSo the |ova|of sound emitted from the compressor. It shall consist o(R3/8inch closed cell polymeric 4.5- 8.5lb/ftodensity jacket that eon|OSesth8compressor. _ STANDARD SCROLL COMPRESSOR The compressor is8nR-410Ascroll-type with 8suction gas-cooled motor. EPDWvibration isolators. internal thermal overloads,automatic reset high pressure switch with lockout after three failures. Rotolock service valves, arid low pressure transducer.The crankcase heater and adioohargo check valve shall be provided for additional uyoiem pmteoUm)from refrigerant migration during off cycles. DUAL COOL consists of an additional koo-cooling chilled water/glycol oui| and is constructed oicopper tubes and hvdmohi|icc0uNd alurninurn fins.A 2-way or 3-way modulating valve controls the chilled water flow passing through tl�ie cooling coil. The free cooling coil |aoJategkaily located in the return air stream V/all air-cooled unit tneither precool o[0�|�nOo 0e�rhe��enioMOg�g ��oe��oo coil. L|obed iCOM onn1m|a [lie ooUvaMnw'dVgctivaUnnarid modulation<dthe cooling Sources allowing the system tofunction as modulating chilled watert"g|yCo|system, nna compressorizedsVstem.orCnmbiDationOfboth.StandondpnasaureratinOiu15OpoiO (1034 kPa). Optional pressure rating iS4OOpoig/2758kPa\. This iva4pipeaysieni. ELECTRONIC EXPANSION VALVE shall boCfstepper-motor type, The EEVshall maintain consistent superheat cf therefriger8ot vapor at the outlet of the evaporator coil over the unit's operating range.The valve shall be controlled by -a separate electronic controller. Superheat shall bedetermined through the suction prexaum-iempeokune method, FILTER~The filter shall bmdoop'p|ented. 2ill(51mm) thick with aMERV11rating efficiency based onAGHRAE52.2-2UO7, DOUBLE SKIN PANELS The exterior panels ohu|be internally lined with 20 gauge galvanized steel,sandwiching the insulation between the panels for easy cleaning. SMOKE SENSOR-The Smoke Sensor samples the return air and shuts down the unit upon activation and sends visual and audible alarms. Dry contacts are available for o remote customer alarm.This smoke sensor io not intended to function as orreplace any room smoke detection system that may borequired hvlocal ornational codes. Document generated 16 September 2022 03:00 PM (EST). VERTIV LIEBERT PDX OPTIONAL FEATURES AIR COOLED HIGH TEMPERATURE SENSOR-The High Temperature Sensor is mounted in the electric panel with the sensing element in the return air flow.The high temperature sensor shall immediately shut down the system when high temperatures are detected. CtONIP.RESSOR OVERLOAD SENSOR A pair of 4/0 contacts shall he factory-installed and wired to each compressor to indicate Con ipressor Overload. REMOTE TEMIDERATURE AND HUMIDITY SENSORS Arc provided in a vented case for mounting in he room to be conditioned. Includes 30 ft. (9m), 60 ft. (18m), 90 ft. (27m), 120 ft.(36m), or 150 ft. (45m) of cable supplied for connecting sensors to unit. REHEAT/HUMIDIFIER LOCKOUT—The op?ion includes the relays necessary to disable the reheat and humidifier from an external customer supplied 24 Volt AC signal while on emergercy power. LOW VOLTAGE TERMINAL PACKAGE One(1)extra N/0 common alarm contacts shall be provided.Two(2)extra remote shutdown terminals shall be provided.One (1)pair of N/0 contacts shall be factory-installed and wired to indicate Main Fan Overload.One(1) pair of N/0 contacts shall be provided for Liqui-tect signal shut down. (Liqui-tect not included). REMOTE HUMIDITY CONTACT allows the unit's humidity controller to control a humidifier outside the unit. Power to operate the remote humidifier does not come from the Liebert PDX unit. FLOOR STAND Is constructed of galvanized stool ane available in heights from 6"to 2X'(1 50mm to 610mm)with vibration isolation pads provided on the adjustable legs, REniRN AIR FL OOP STAND ASSEMBLY ilie upllow unit with rear return air configuration shall be suppli&J with a skirted-floor stand assensbly. The floor stand assembly shall be constructed of galvanized steel with powder coated panels and supplied with air filter,The floor stand assembly shall be 24-1;8 in (613mm) high and have adjustable legs with vibration isolation pads. It provides a roar return duct flange and removable panel for filter access. UPFLOVV UNIT PIbE IrUM(S)are available in various configurations for upflow units:ducted air discharge with solid panels or 2 way,3 way;or 4 way air discharge with grilles. Each plenum is constructed of 20 gauge steel with 1"(25.4mm), 1 1/2 ib, (,63kg)insulation and is powder-coated with RAL7021 black gray matte color paint to protect against corrosion.The ducted air discharge plenum is available in 18 in.(457mm), 24 in,(610mm),30 in. (762mm),36 in. (914mm),42 in. (1067mm), or 48 in. (1219mm), and the air discharge with grilles plenum is 18 in. (457mm) high. DOWN 'LOW UNIT PL ENUMIS)are available in variOLls heights. Each plenum is constructed of 20 gauge steel kivith i..(25mm), Jih (0.68kg) insulation and is powder-coated with RAL7021 black gray matte color paint to protect against corrosion. The ducted air return plenum .s available ir, 18"(457mm),24"(61 Omni),30"(762mm), 36'(914mm), 4Z'(1 067mm), or 48' (1219mm). LIQUI-TECT SENSOR-The water sensor is a hermetically sealed solid state device with no moving parts.When the sensor detects the presence of moisture,the alarm system is activated. s - DPN003381 REV: 3 Z Page:2/2 REV DATE: 8/18 U 1f J Document generated 16 September 2022 03:00 PM (EST). V A ,� VERTIV LIEBERT PDX F�, CABINET DIMENSIONAL DATA UPFLOW MODELS :o o ° 301/4" 34 3/8" (768mm) (874mm) Duct Flange • 4 11/4" Top View ° (32mm) 32 5/8" (827mm) Duct Flange (39mm)� • 5 5/8" ( 143mm) 34" 24" (864mm) ® (610mm) 771/2" ( 1970mm) Shaded area indicates a Recommended Clearance for recommended minimum unit installation and for servicing clearance be provided for these components if equipped: component access. Reheat,Filter Clog Switch, Econ-O-Coil Valve,or Gravity Drain 341/2" Connections. (876mm) Front View DRY WEIGHT Ib(kg)APPROXIMATE Note:Unit with front return shown.Bottom return with Liebert PDX Model No. PX011 PX018-023 PX029 rear return floorstand is also Air Cooled 600(272) 670(304) 700(317) available(24"height rear return floorstand is Air Cooled w/dual cool 700(317) 750(340) 790(358) I required for use with bottom Water/Glycol 620(281) 690(31.3..) 720(327)` return unit). GLYCOOLT"'or WaLet Glycol w/dual cool 720(327, 771(11411, 81,0;367) Liebetl PCW Mode!^,No, PW011 PWO17 P`I 029 Chilled V�/a r 575(,260) 600(27/2) 650(2941) $� ___ DPNO02937 REV: 7 Z Page:1/1 REV DATE: 4/18 Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT PDX PIPING SCHEMATIC AIR COOLED MODELS WITH TXV LIEBERT MC CONDENSER Check Valve WITH LEE-TEMP RECEIVER Relief Valve Service Valve LIQUID RETURN_ LIEBERT MC CONDENSER — — — Head Pressure Pressure Transducer Optional FieldLEE-TEMP RECEIVER Control Valve h�st�illed Fusible Pfug CONDENSERCGI LIOUID _— I I CONDENSER COIL LIQUID I I Indudes',adory provided nvi�rted �," Trap. No external trap required'. i _ . ....,.,.. NOT GAS i Includes factory provided inverted DISCHnR G E trap. No external trap required. HOT GAS DISCHARGE � I LIEBERT PDX UNIT LIQUID I I Sensing EVAPORATOR I I Digital Solenoid Valve Bulb COIL SUCTION 2 I For rises over 25ft.(7.6m), Service trap every 20ft.(6m)or evenly Valve divided 7 heck Valve COMPRESSOR Service External I Valve Equalizer Trap at base of risers over 5ft.(1.5m) A II HOT GAS DISCHARGE J Thermal Expansion Solenoid Sight Filter Drier LIQUID RETURN INTERCONNECTING Valve Valve Glass PIPING FACTORY REFRIGERANT PIPING SERVICE/SCHRADER(ACCESS)CONNECTION NO VALVE CORE ——— FIELD PIPING SERVICE/SCHRADER(ACCESS)CONNECTION WITH VALVE CORE Notes: 1. Schematic representation shown. Do not use for specific connection locations. Components are not supplied by Liebert but are required for proper circuit operation and maintenance. 3. Traps must be installed and horizontal lines pitched to ensure proper oil return and to reduce liquid floodback to compressor. Pitch horizontal hot gas piping at a minimum of 1/2"per 10 feet(42mm per 10m)so that gravity will aid in moving oil in the direction of the refrigeration flow. i 4. Do not isolate any refrigerant cirdbits from over pressurization protection. $ DPNO02929 REV: 8 Page:1/1 REV DATE: 12/17 s ' .9 Document generated 16 September 2022 03:00 PM (EST). A VERTIV. LIEBERT PDX PRIMARY CONNECTION LOCATIONS UPFLOW AIR COOLED MODELS G1 L1 Optional piping exit location out the right side ECR ECS panel in lieu to top connections.Please advise if top connections(as shown)are preferred. • ECR O Y 1 ECS CDP L1 HUM E1 LV1 G1 5 5/8" CDA FRONT OF UNIT (143mm I TOP VIEW FRONT VIEW RIGHT SIDE VIEW POINT DESCRIPTION X in.(mm) Yin.(mm) Z in.(mm) CONNECTION SIZE in. PX011 PX01tl3 PX0?? PXC=i9 L1 LIQUID LINE SYSTEM 25-5/8(651) 3/8 1:2 G1 HOT GAS DISCHARGE 5-1/8(130) 27-7/8(708) NIA 1/2 5 8 I r CD CONDENSATE DRAIN N/A 16-5/8(422) 3-1/8(89) 3/4 NPT FEMALE CDP ICONDENSATE DRAIN WITH PUMP 3-114(83) 5-7/8(149) 1/2 HUM 1HUMIDIFIER SUPPLY LINE 29-1/2(749) 26(660) 1/4 5 (;Cl„•i.;- (?ll.�4SUPPI Y.. 3-1%4 i83) 1..1:£1 -.CR ;EC:ON-0,"011 RETURN j3• 8-14. 21Q; NIA El ELECTRICAL CONN.(HIGH VOLT) 30(762) E2 ELECTRICAL CONN.(HIGH VOLT) 31-114(794) 27-3/4(705) 718,1.3/8,1-3/4 Q6 LV1 ELECTRICAL CONN.(LOWVOLT) 1-112(38) 27-1/2(699) 1 LV2 ELECTRICAL CONN.(LOWVOLT) 26-1/2(673) Notes: Q1. Drawing not to scale. All dimensions from rear corner of unit including panels3. Supplied on Dual Cooling Systems only. and have a tolerance of±1/2"(13mm). Unit with front return shown. Bottom return with rear return floorstand also available. 5. All refrigerant&water piping connections are O.D.Copper except as noted. Field pitch Condensate drain line a minimum of 118"(3mm)per 12"(305mm) All units contain a factory installed condensate trap. Do not trap external to the unit. A6. Concentric knockouts to be used based on field supplied conduit diameter. Drain line may contain boiling water. Select appropriate drain system materials $ The drain line must comply with local codes. DPNO02939 REV: 10 Z Pagel/1 REV DATE: 5/19 ti Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT PDX try 1P,C����:' ELECTRICAL FIELD CONNECTIONS UPFLOW & DOINNF LOVI MODELS 1. High Voltage Entrance.Supplied on top and bottom of electric box. Knockout size 01.75in (44.5mm). 2. Low Voltage Entrance.01.375 in. (34.9mm) hole located on bottom of Electric Box. 3. Three phase Electric Service and earth ground.Field supplied. 4. Three phase connection. Electric service connection terminals on disconnect. 5. Factory installed disconnect switch.Fused disconnect switch provided on units. 6. Earth ground connection.Connection terminals for field supplied earth grounding wire. 7. Earth ground bar.Connection terminals with factory ground from each high voltage component for field supplied earth grounding wire. 8. Control and monitoring section of electric box. 9. Remote unit shutdown. Replace existing jumper between terminals 37&38 with normally closed switch having a minimum 75VA,24VAC rating. Use field supplied Class 1 wiring.Two additional contact pairs available as an option (labeled as 37B& 38B, 37C&38C). Replace existing jumper for appropriate pair as done for 37&38. 10. Remote Alarm Device(RAD)Connections.Alarm connections may be factory wired or field wired. See schematic, RAD1- 4,for factory wired alarms. For field wired alarms, use Class 1 wiring to connect normally open contacts between terminals 24&50,24&51,24&55, or 24&56.Suitable for 24VAC. 11. Smoke detector alarm connections.Field supplied Class 1 wiring to 1 Amp,24VAC maximum remote alarm circuits. Factory wired contacts from optional smoke detector are#91-Common,#92-N0, and#93-NC. Optional smoke detector trouble (SDT)connections#80&#81. 12. Common alarm connection. Field supplied Class 1 wiring to common alarm terminals 75&76 (and optional 94&95, and 96&97),which are factory connected to normally open contacts, 1 Amp,24VAC maximum on common alarm relay(113). 13. Heat rejection connection. Field supplied Class 1 wiring to heat rejection interlock terminals 70&71 which are factory connected to normally open compressor side switch (self contained units only)or to GLYCOOL relay K11 (GLYCOOL units only). On Dual Cool units only,connect auxilliary cooling source terminals 72&73 to relay K11.See indoor and outdoor electric schematic for more information. i 4. Rehe4t and Humidifier Lockout. Optional emergency power lockout of reheat and/or hua lidifier:Gor nections;.122&,11-'83 wrr, provided for remote 24VAG source and Glass 1 wiring by others. 15. Main Fan Auxiliary Switch.Optional main fan auxiliary side switch.Terminals located on customer connection terminal block for remote indication that the evaporator fan motor/unit is on. Field to connect 24V maximum, Class 1 wiring to connections#84&#85. 16. Optional Condensate Alarm(Dual Float Condensate Pump only).Relay terminals located on customer connection terminal block for remote indication. Field supplied Class 1 wiring to connections#88&#89. 17. Optional Remote Liquitect Indicator.Optional remote liquitect indicator for unit shutdown.Terminals located on customer connection terminal block. Field to connect 24V maximum, Class 1 wiring to connections#58&#59. 18. Optional Analog Inputs#3&#4.Customer connection to terminals 41,42,43,44 for analog inputs. 19. Spare Terminals for Optional Devices.Customer connection when optional device is supplied. See unit schematic. g DPNO04594 REV: 0 Z Page:1/3 REV DATE: 3/18 E `o `Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV LIEBERT PDX & PCW ELECTRICAL FIELD CONNECTIONS UPFLOW & DOWNFLOVYMODELS 20.CANbus Connector.Terminal block with terminals 49-1 (CAN-H)and 49-3 (CAN-L) +SH (shield connection). The terminals are used to connect the CANbus communication cable(provided by others)from the indoor unit to the Liebert MC Condenser. 21.CANbus Cable. CANbus cable provided by others to connect to the outdoor condenser and optional PRE unit. No special considerations are required when the total external cable connection between the indoor unit and outdoor unit(s) is less than 450FT(137M). For total external cable connections greater than 450FT(137M). For external cable connections greater than 450FT(137M), but less than 80OFT(243M) a CANbus isolator is required (Contact Factory). Cable must have the following specifications: -Braided shield or foil shield with drain wire -Shield must be wired to ground at indoor unit -22-18AWG stranded tinned copper -Twisted pair(minimum 4 twists per foot) -Low Capacitance (15pF/FT or less) -Must be rated to meet local codes and conditions - EXAMPLES BELDEN 89207(PLENUM RATED),OR ALPHA WIRE 6454 CATEGORY 5,5E, OR HIGHER 22. Do not run in same conduit, raceway,or chase as high voltage wiring. 23. For CANbus network lengths greater than 450FT(137M)call Factory. OPTIONAL COMMUNICATION CONNECTIONS 24.Unit-To-Unit—Plug 64 is reserved for U2U communication. 25.Site and BMS—Plug 74 and terminal block 3 are reserved for Site and BMS connections. Plug 74 is an eight pin RJ45 for a Cat 5 cable.Terminal block 3 is a two position screw terminal block for use with twisted pair wires.Only one of these connections can be used at a time. NOTE:Refer to specification sheet for total unit full load amps,wire size amps, and max overcurrent protective device size. a DPNO04594 REV: 0 Z Page:2/3 REV DATE: 3/18 Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV. LIEBERT PDX & PICA! ELECTRICAL FIELD CONNECTIONS UPFLOW DOWNFLOW MODELS � 5 � d • 'i III J UPFLOW UNIT DOWN LOW UNIT UINDMUE113 ❑ 18 � ° 1:1 N 10 . 0111 U 13 13 ® ❑ ElIII o [E][3 El ,9 �U U14 11 RI° p 3 ® ® ® ® ® = 14 "' ®o N 20 oil D ©° ° IIII s , ® 1s o ®° ° 9 III °°°°° o ®° SII ° ® ® ® o U19 0111 ®° 5 ° •� B 4{ e ° A ° A ° ° ••ti� • •' g m ° m j O I q:4 °® a�Pe�6 III • ,e ° �¢ ® e 12 ®E1111 U9° A .• � °gr t 0 �° 10 �. ® ®° bi is o N 11 Ella ° 3 r- - 0 �° o 11 O �° 7 19 0 6 8 24 25 V9 Q° a 1 High Voltage Entrance Low Voltage Entrance 2 9 9 Terminal Block For 15 $ Customer Connection DPNO04594 REV: 0 Z Page:3/3 REV DATE: 3/18 ° Document generated 16 September 2022 03:00 PM (EST). A � VERTIV. L I E B E R T P D X �:� ' :,_ � ELECTRICAL FIELD CONNECTIONS UPFLOW MODELS i \\ 1 2 I CO Sol 0 4 3 o � � t II � II fl � I j \ 2 0 � I A.I i I I 1 O Opening for field wiring.Suggested entry point for HV field wiring to unit. O Opening for field wiring.Suggested entry point for LV field wiring to unit. OWire tie anchors.Use to secure customer wiring. Notes: AWire needs to be routed outside Electric Box to Low Voltage knockout on bottom of Electric Box. �I DPNO04596 REV: 0 Z Page:1/1 REV DATE: 3/18 lY 8 7 6 5 4 3 2 1 AITEPtiAlE PI3 ,EATREECiIw 4 ALLfE1DWPAU LOBEPERIfULlLOE4IISEo]PP6V OOMlCfQ6 P1r. uNE I Lt-eR �I e]e9raDn Parma u'' EM, raTAVNE i Rli aPiASEEMvmzr6cls vE1% rz w+aswla®naonwwuma sEElwruraEvurE varACE FDRVANSUR'LY ]]MASE I I - - IPS W 669 n 61J la, R--�4 NNWOG �E6 ypar.aNlo]I6i UifScn 6lOu➢6EnHF➢mmAb n.xNL%R %11EE0NG STPPLY T'— m'1BI61 ISI SH lnf WINZSY.H WSANNf64NL19EVOTADEOVERIW66151EY rIEO`ROUl 631 - p-t aSRAY 66, MMU IYZ 6K-�I, p TPOHSalfE0.5lHPnt I I ® 0196TA19C PPE551.RE C0.6REWRO+eRw66ANFAIHu19L WNIRl YQ3ACfOrHUWDS�SrB,lt3®xJ FACTONY xOwI®LWNIM SwitN Bx BR (w W W 2N 638 dRLU90f] - 0 a91 --j] CwfR0.13PG) %ffUf FUSEyWYEEPNR�OvF�IA�CFl��SFD ax3 FOrmi +M W ANALOG i-EE%ll'fruo101' S'IFDfoRPRawRYEBraFRUWIfMpRdd 6— il.tl.�CT0 SWE UODEL5J WOOL IM &C-�13 �1� 5 i OPIIIXLL6WF� IFGIP4>Fm6PIPUIS�RF9 Ni�IDw A9IKNI NH -rte_ 0.911aININ)lLPpul! W RE4,mElraunw EE3DrotolaEaxv,ux ENIMPAWBO ' p25II 211 a i flOPRwLLmM1FAVAUAUARrSOEMnPt TEwIW46 LOGr®wR9D%90W COWE'm BLI^� t 0 j �RS{i) TILII 9R L N N 163 X-1 Ei GM Et 9.OP110NLE46ifGe96YNA£RI➢LYWIOr 9EHFAi ArpO(+NMOr6h NrlaC116r15 D 6,9- ] BH-wl[R,cJ �ID3Ao-iBR 13 R 41 6S3 ISI /}t OR R 41J ISJ R ul q •II-GWY Q Pts t60Pn6rWLCOOASAfr PIA6NHwREIArrFw¢w5l0uT®WwNrL W1a'Aill@]f D $ _ � ❑❑ a❑ ASIPS NRr IB' ]{191.t L$fERnNlo-rsT PCB CONTRCLFSES ,A LL53Y SUPPOFDOW URWDIHIWTSONr, TD 5 rOR-IotlRl 1-Nxo�®(--I H 1}2 OR W �}3 Kt1 nrQiY� EI PS 1D ,i IAE V10.'BUbDS51EY6 MBN416WILriS.m RE9EIMERtJ,L1[RW fOA90 ^ 60J Ytio61(M) (.IAIO�A-,I U m L, IPL+ R=] EWRE3R =TERNNUS H NJIEB OYF)dLW].uVNP6r.91MAreEU�JMEc1EDPoR]OBEG SEE NO]E6 OR ]e i ]]O psD9 3C 7>e mm 366 17 RSDI , At Nx 1 -�- -}k- S3--II��-it- 35J F ITE "j�-BR j b] -�-oTo-A R B5 `�� NOIE6 'bl i-di M] 15 9R9 RaDTE I p- R--S i j �Tl_ _� IXWJAw nR 1 j t-NWPE6 ENR, SE-TORt 51 .1p MY5IAi5E]LSpa DmKa� `II�I�c�I�P�{/ELt�� 1R---S i I } i 10., Oli I SW NF Ofl 16A S5556 R-flL1ER¢➢G SW1]OIA QS IOI.E�NOCtlLi¢3AYw 10 rJ01C( Bi- �/ OR ! t1 PAD I W.NHMOIr6Exfl]R OINK+ EIECInOfiT � rTF-�qi 6, Wi iHIPqT NiRESYd@1q 6PqRE5Qlf I � 20 sff - 20 frp UAr WNOCfIW6 r2N.t➢4 leffATO]ROLIOi -Y um-uouel�saE+ao, w IDraROia+ mo W1El B51�I p SIA A�� C,AUKI I' IDJ -Po ci-P---�-f-Ofl 6] !j I ^^� V I OR-y fd)•-j--t OR-- IS.tr,l9 LPr,-IGWfItES51.71f1RN6PE&, X —F—F.-l- ------------- A O L_ \/ .--FAVCONfILfgi 111 NQ.RE1fAi9Plffx@ffILIOR r9 rn]E�e9�P.__{H - -m9 ' aeaH�en el j ecL,nEnvmNro I LDR R-% +6� I f �]_-_---_�-- I j O- m-ImrwislAP�lrlmc Rs,+-RENF.rsuEn•srus ss w n _ !j -- --- _ R_ --_-- -ry a-wwDRunwrwac i xPl rvx6swxcERuseu�,+ a SEE BRt6R SEE r---- R-- _ 361 - R q C C Y E}I Bt S0� NO E T!�•\�� 61 ; NyNFU RyL O.LO O�eN w VE '25 ] \-�M-En 3 -LcS6I, Y-j i! 019 ISDrfl SOi + III •fS Os-�FAw�ur]IQ+L Ie ICCEl:AVEab !j Sbl II-5 1O ] Pyr R e9� m-rATIEFL .) G`-LPDE—ERAO 4 aSIWA3ValANECIIaSAL5O9EE1dlE5 y3,1y,,],19�31,nxA818 I i Ot] j P 9xl I O,A-IOT,AEO tl G'AR.O?OBEAfrPL3PAWea163Ar Y 4-1 49 II3 II-2 I 6 -0II'r11f6 O,1-IIOIDIPESOFrmOApI rIWC 30 LPSa-OY0B16t1E0.1P60.frTI Tf FARn1Pfl01RA WMEC11pN !1 R n I.. JJ 161 0,].IDi P✓5619ASSt ridlG 31 SWROI 0000 00 can c+Aux, i i SK zM za1 SEC eR�9+ a,s.ms9�ww,TRuc cru s�a,Tn+A�vaw.elu P U. Sal O,]-rD= CwF9.O/LLmYNiF,iROY5wi01 30 mAwGH6Nr cR>trpwREs ec--�} u ! st•t A W -6N_ -_--_— --_--- s3a 30 osis6.smvLr�.wsamR s9 e�'el--e6L Pu,+�loam,n 1. aM@RES'DR tct' Alm L, ! ! SA8 &4 W 3Pv KASW9D Si] n.ittK1110liRVEiOmEF ] HIS.REUr I] Hr3N iE3a£AAMiES3AT � xl I I Sib .-------- __-____-- -- 51,1 16-WU]IONTWAmn1619 0 XG6e1-IOT MS6YPAESVILVE, 31 I j UHW-OPf016pIAr00.5 LOR-LWRE6i9Nr60w9RFI.SY II I 5b, �-R BI(�8(- P515HE1D 36P 4645-LNdIiAVND4WNY90E5M101 20 Q j SiBV p- COLWAWWIN,SBAWIt 11 EWIJOMEX,63N"SEE- H 4.. j 34] ��--w o3 �LWNLLFE4T MCI-0-P➢p1Es1A91DE O 19 IN DSVAIININrM 36 %691 R�{ u 35 wc-Ia<wiExnormlmHnuL w Ha30RFA R Nla L2 I ; �-, -a6R ]6] 13RDN{—`_J%rzroD R,' so.oPSUloam+ er ��;I�INMNq 25 o 3s, zIx I 3/]EnES -(��.������i /%.,..�� J�������� s43 3N ---M1— I.'Ht 3As ,-R---- , uY.15 w.rv.HL6rFl[N%NFMV4YE �3 9f.5M,F6EIECrOR PRAY D wru+Dws6wmuvwNerP�nemws]swLTxumEiel ! i I I oz O—T _wTEfi Im.NwaLI6g*NALu'ffn sua:,v a sPc.siArcPaE.mFlEwxlu a i i 1M aWLT3 9L] I IE%1 1}.1&49 HNA NOIYIApI�FAAWw ,I B 40 j la] 1W +zJ °i 346 ���/// 3.9 '-H-� 40 B j I-TI P-lo`POWER1. W 7St R- -R 353 3S6 N R L'S 35.:N] sE�rarEe `� F.nomsuvlaEuwr:mTs6Eww+c In I i l Is] 'Exl ' s,-0 _ Px�iaSrs'�rrra:�z.wiiwnliro {18 p A of 1 ZBR �_— 53 NOrE6-fIJ— --.1�� /-q ..svlo�AwnE.YFswlOEoblov,lusTvax P]ffAf 4Jr 45 I 1 'T+ --- y —� I+ IUFOLIX6W16NAnNEOW16 ll` 31on 36n 369 5— - ! a OFENCWPAl90ARD WMdCIION IIFK I 9xJ 9.9 AJ ® O PIIIG d9RAEelNO 334 319 315 O 161LTla&OIXOOI+ECRw ONWInPOl60A10 REIffATI PRQ 1 aYFS a,6' �--� ❑0 C3 rHaTAL51PPIbNKCn6NFa1F�I6- l ~ FUSEArIDIRfJSi0Ww09 ❑ COIN mE]ECIIWNGS P Il 3R¢ YJ `--� ISSg M57VUELS MY af50 Ja 6D wP6 P.. cw6 -R 3 �] eu C- eI } �SEENOTEI �R 3]-0 n®BPoa�pxY111E 1 cP i VERTIV. 9EE W,E 19 tIu � 1 33-0 -s-w�}(�-w � �\ 3za �� /� ��na,• "w,9An:lmcnrvataotm ELECTRICAL SCHEMATIC —55m ❑'�"�R LPn . b,�I ."a '+� ,, u®ERFDxax A El—A x.GCONrAtls � wwTmis SHADEDwAAcE4w9a4AArYeBREEANlaSxESs I��s�LO.7 sel 6L---.--eL ;aat3---'-Rw-.o--tix�Pr,lI-r-'a1I--BeKc--",2, aVFLONN9':TER WF-._ 't9 x[ rofAc[ ICON!GLOBAL CONTROL! -------- �FA CPFNwINFRARED HUMIDIFIERMEAIR I WATER I GLYCOL I GLYCOOL 60 Dpi-aR 356 �sffrprErz 60 '�LUNASLWa) wnmDlDS TOL'Gi SCREEN REFERENCE -e-R SIJ R�OR��^ll FSaaOLYaE 5ET50R DAVDVANLOa O9Nt115 W(-�Ba 513 Z1 D,aORZ� I35 136 auNaDREN moms 323662 T 8 7 6 5 4 3 2 1 wRU Na 186215 REVS Table 3.2 Electrical data by Reheat Option for PDX with Humidifier with Condensate Pump .•. 208 39.9 48,6 - 60 36.5 41.0 50 P.53.2 ;61.9 70 45.7 .; ;':'50,. 3_ 48.7. 56.8, "7& . PX011 380 - - - - - - - 460 18.8 22.7 . ;,;:,25,;': ..:.17.4 19.5`:`'_ 24.6 28,:5'.`;. "' 35. 575 15.7 19.7 20 15.3 16.7 20 3 24.2 25 2M-!k 47.5 - 230 63.1 76.0 90 45.3 51.0 70 - - PX018: 380: 33.4 40.2:.='.' 45'.':: :,;'24;3., ,. .,..27.3'..', 35 - 460 '30.5 36.8 40 .21.9 24.6 35 - - - 575.. 24.4' '29.5 30 19.8,.. .'21:9 30'': - - 208 72.7 88.0 100 52.7 59.7 , 80 - - 230 68.3 82.5. "100`. 50.5 57;5 80 PX023 380 37.2 45.0 50 28.1 32.1 45 - - - " • 460;,%` :" 33'.7 -:-;.: 40z8:,.. ..50 °"' 25.1 28.6- '40_`•,.: . - 575 27.1 32.9 40 22.5 25.3 35. - - - 208 "/6.2 92.4',.:,; Y100.`,: 56.2 64.1 230 71.8 86.9 100 54.0 61.9 90 - - - PX029 ;` '380_•= .39.2 47.6, 60, ,-30.1. 34.6';: - 460 36.0 43.7 50 27.4 . 31.5 , 45 - - - 575` 34.9 a:40' .., 24.1 27.3 , 35 _ FLA=Full Load Amps;WSA=Wire Size Amps;OPD=Maximum Overcurrent Protection Device 32 Vertiv I LiebertV`PDX'"and PCW'"System Design Catalog Document generated 16 September 2022 03:00 PM (EST). A VERTIV LIEBERTO iCOMTM PRODUCT INFORMATION UNIT MOUNTED DISPLAY I ' i I I The Liebert&COMTM display is a 7-inch capacitive, color-touchscreen display in an ergonomic, aesthetically pleasing housing.The display and housing will be viewable while the unit accent panels are open or closed. The display can be easily detached to view while the panel is open. Menu Layout-The menus will be broken out into two main menu screens: User screen and Service screen. The User screen contains the menus to access parameters required for basic unit control and setup. The Service screen is designed for service personal and provides access to advanced control setup features and diagnostic information. Password Protection-The display will contain two unique passwords to protect against unauthorized changes. An auto hide/show feature allows the user to see applicable information based on the login used.These four-digit passwords may be customized according to User preference. Unit Backup and Restore-The user shall have the ability to create safety copies of important control parameters. The display has the ability for the user to automatically backup unit configuration settings to internal memory or USB storage drive. Configuration settings may be transferred to another unit for a more streamlined unit startup. Parameter Search-The display has search fields for efficient navigation and parameter lookup. Parameter Download-The Liebert iCOM shall enable the user to download a report that lists parameter names, factory default settings, and the user programmed settings in .csv format for remote reference. Parameter Directory-The Liebert iCOM shall provide a directory that lists all parameters in the control. The list shall provide Line ID numbers, parameter'labels, and current parameter values. �I DPNO04350 REV: 2 Pagel/3 REV DATE: 3/20 Document generated 16 September 2022 03:00 PM (EST). ti A VERTIV LIEBERTO iCOMTM PRODUCT INFORMATION UNIT MOUNTED DISPLAY Context Sensitive Help-The display will have an onboard help database. The database will provide context sensitive help to assist with setup and navigation of the menus. Display Setup-The user has the ability to configure the display information based on the specific user's preference. Language, units of measure, screen contrast, home screen layout, back light timer and the hide/show of certain readouts will be configurable through the display. Additional Readouts-The display has the ability for the user to configure custom widgets on the main screen. Widget options will include items such as fan speed, call for cooling, call for free cooling, maintenance status, call for hot water reheat, call for electric reheat, call for dehumidification, call for humidification, airflow, static pressure, fluid flow rate and cooling capacity. Status LEDs-The display will provide the user with the unit's operating status using an integrated LED. The LED will indicate if the unit has an active alarm; if the unit has an active alarm that has been acknowledged; or if the unit is on, off, or in a standby status. Unit Alarms—All unit alarms are annunciated through both audio and visual cues, clearly displayed on the screen, automatically recorded in the event log, and communicated to monitoring plug connections. Event Log—The display will automatically store the last 400 unit-only events (messages,warnings, and alarms). Service Contact Information—The display has the ability to store the local service or sales contact information. Upgradeable—Display and Control Board software upgrades are performed through a USB connection. Unit-to-Unit(U2U)Communication—Communication via private Ethernet network allows for advanced control functionality(Teamwork modes, sharing sensor data, Standby Rotation, Lead-Lag, and Cascade operation). Temperature Control- Precision temperature control is maintained while maximizing efficiency based on a user entered setpoint and tolerance. Various Control Types- Proportional, PI (proportional-integral), or Intelligent control types can be selected for supply or return temperature. These control types have been developed to maximize component life.and maintain precise environmental control. . Timers/Sleep Mode-The menus shall allow various customer settings for turning the unit On or Off. Sensor Calibration-The menus shall allow unit sensors to be calibrated with external sensors. MaintenanceMeliness Settings-The menus shall allow reporting of potential component problems before they occur. DPNO04350 REV: 2 Z Page:2/3 REV DATE: 3/20 2 Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV LIEBERTO iCOMTM PRODUCT INFORMATION UNIT MOUNTED DISPLAY Options Setup-The menus shall provide operation settings for the installed components. Auto Restart-The unit will return to its previous operating status after loss of power. Units can be stagger started to minimize system current draw. Auxiliary Boards-The menus shall allow setup of optional expansion boards. Various Sensors:The menus shall allow setup and display of optional custom sensors.The control shall include four customer accessible analog inputs for field-supplied sensors.The analog inputs shall accept a 4 to 20mA signal. The user shall be able to change the input to 0 to 5VDC or 0 to 10VDC. The gains for each analog input shall be programmable from the front display. The analog inputs shall be able to be monitored from the front display. Diagnostics/Service Mode-The LiebertO iCOMTm control shall be provided with self-diagnostics to aid in troubleshooting. The microcontroller board shall be diagnosed and reported as pass/not pass. Control inputs shall be indicated as On or Off at the front display. Control outputs shall be able to be turned On or Off from the front display without using jumpers or a service terminal. Each control output shall be indicated by an LED on a circuit board. DPNO04350 REV: 2 Z Page:3/3 REV DATE: 3/20 Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT® iCOMTM UNIT TO UNIT NETWORK CONNECTIONS UEBER Q CW, UEBERTO CWA, LIR } 0 DS, UEBERTO DSE, LIEBERT® PDX, LTO PO RS485 / SITE AND BMS COMMUNICATION ETHERNETCONNECTIONS ��� �� I I I I I i 1 2 I � DETAIL A .0 qP.A 71 P72 E5 T HERNET CABLE P74 P64 I (IELD SUPPLIED) I UNIT-TO-UNIT NETWORKING SWITCH t I (FIELD SUPPLIED) P76 J���J� ICOMTM MICROPROCESSOR AND 110 BOARD P75 o TO/FROM OTHER r lnl� NETWORKED UNITS ooh P95 � o o P100 m °- P95 DVI-D CABLE CONNECTION TO 7-INCH ICOM DISPLAY P100 POWER SUPPLY TO 7-INCH ICOM DISPLAY DPNO04351 REV: 4 Z Page:1/2 REV DATE: 2/20 Document generated 16 September 2022 03:00 PM (EST). A VERTIV. LIEBERT® iCOMTM UNIT TO UNIT NETWORK CONNECTIONS UEBERTO CW, LIEBERT® CWA, LIE E TO DS, UERE TO DSE, LIEBERT® PDX, UE E T 0 PCW ETHERNET CABLE (FIELD SUPPLIED) 11 0 11 P71 P72 E5 � P71 P72 E5 ;TB3 P74 P64 ;TB3 P74 P64 P76iCOMTm N P76 iCOMrM N MICROPROCESSOR a a MICROPROCESSOR a a AND VO BOARD AND VO BOARD P75 o P75 ° a ° a�N P95 �g P95 foo o P100 � o Pi00EB a � P95 DVI-D CABLE CONNECTION TO 7-INCH ICOM DISPLAY P100 POWER SUPPLY TO P95 DVI-D CABLE CONNECTION 7-INCH ICOM DISPLAY TO 7-INCH ICOM DISPLAY P100 POWER SUPPLY TO 7-INCH ICOM DISPLAY NOTE* For dual-unit network configurations only DPNO04351 REV: 4 Z Page:2/2 REV DATE: 2/20 Q VERTIV,. LIEBERT° LIOUFTECTTM 410 POINT LEAK DETECTION SENSOR Product Specification/Installation Guide �e . , The Liebert`a'Liqui-Tect'"410(LT410) LT410 APPLICATIONS COMPONENTS OF THE provides single-point detection of LIOUI-TECTTM 410 MODULE leaks.The point-detection sensor The LT410 is ideally suited for: has two gold-plated sensing probes • Glycol and chilled water cooling, The LT410 consists of a metal enclosure with a hinged top door that to prevent corrosion and to provide . Humidification supply water piping, provides access to the internal wiring accurate readings.The LT410 constantly monitors for leaks,internal through a box connector for installation• Condensate pumps and drains, termination.It includes side access faults,and power failures and warns • Unit and ceiling auxiliary drip pans, of the power and contact wiring.The brackets allow for sensor height any abnormal conditions.Mounting . Overhead piping troughs. mounting brackets attach to the br adjustment and leveling. enclosure with adjustable slots to allow LOCATIONS/PLACEMENT custom setting of the height of the The LT410 is the ideal solution for sensing probes. sensing leaks under a raised computer The LT410 is an excellent choice for: floor or air conditioning drip pans. . Large scale network control centers, Two independent outputs provide added flexibility with the capacity to • Data centers, signal both a local alarm panel,Liebert • Server rooms and closets, cooling unit and a remote building . Unattended,remote shelters, management system or external equipment,such as motorized water • Mechanical equipment rooms, shutoff valves. • Sensitive areas with overhead piping, • Industrial process control rooms. SL-31050R9007-20 1 LIEBERT"LIOUI-TECTT"470 POINT LEAK DETECTION SENSOR �/E RTIC/. Product Specification/Installation Guide DIMENSIONS- TOP, FRONT AND SIDE TOP VIEW 5.85" FRONT VIEW SIDE VIEW (148.5mm) 000, o O ® O 4:I r .46" (113.2m m) ° Form-C relay outputs and power wiring _ 6.35" (161.2mm)—� f 2.25" Adjustable probe (57.2mm) height 0.0-0.51, (0.0-12.7mm) SPECIFICATIONS Power Requirements 24 VAC 100 mA;50/60 Hz,3 VA(max.). I Dimensions,W x D x H 6.35in.x2.25in.x4.46in.(161,2mmx57.2mmx113.2mm) t Weight(assembled) 2.0 Ib:'(0.9 kg) 3 Metal Enclosure I NEMA 1,IP 30 ! ENVIRONMENTAL CONDITIONS Operating Temperature 50°F to 104°F(10°C to 40°C) 4 Operating Humidity. 10%to 95%relative humidity(non-condensing) Operating Altitude 0 to 10,000:ft.(0 to 3,048 m) 4 Output Relay Contact Rating - 2 Form C;3 A rating at 24 VAC. AGENCY LISTINGS i UL UL916 C-UL C22:2,No.-205-M1983 CE Yes. . FCC Compliance . 47 CFR,Part 15 SL-31060 Rev3-07-20 2 LIEBERT"LIQUI-TECT'"410 POINT LEAK DETECTION SENSOR �/E RT V. Product Specification/Installation Guide 00 PLACEMENT ON SUBFLOOR UNDER COOLING SUPPORT EQUIPMENT To a Liebert cooling unit and an optional monitoring panel . i To external power supply or directly from unit(see Power Wiring on page 4) Leak detection zone (directly beneath unit) W w O U O O U O p p ZZ U Z Z U d 0- N N N WIRING INTERCONNECTIONS Circuits are shown in powered,non-alarm state. Gold-plated Probes NOTE:All power and alarm connections must be Class 2 circuits. Height adjustable 0-0.5"(0-12.7mm) Rea WiJre�s, • 24 V,AC/DC Alarm Contact Rating, Alarm Contact Rating, .. s @ 0.10A,50-60 Hz,DC' i 24 VAC @ 3A", 24"VAC @,3A" 'Class 2 Circuit'Only Class 2 Circuit Only'. Class 2 Circuit Only SL-31050_Rev3 07-20 3 1 LIEBERTO LIOUI-TECTTM 410 POINT LEAK DETECTION SENSOR Product Specification/Installation Guide V E RTI V POWER WIRING WIRING TO AUXILIARY ALARM PANELS The LT410 is rated for 24 VAC,50/60 Hz,and 0.10 A. The LT410 has two Forrn-C dry contact alarm output contacts:one orange wire and two yellow wires.Each Liebert'°'DS,DEE,r`W,PDX,i (;W, contact is rated for 24 VAC at 3 amp. liri-PSI=� § v"li'tl iC01A LT410 (8 ton) Liebert"'),.LS&,CW,PDX, TB1 TB1 LT410 f GV' of (8 T5(24V) Red Orange Wires Cooling Unit 35(Ground) Red 1-NC • 1-COM 24(24V) 1 NO 50,51.55 or 56 _yxe„y T2 Ta Location of T5(24V) Note:Terntinai 50 no,avails b ra on Ndini lvlatat(8 tort) T5 connection on main controller board of G3 1 iebcrt`'tJiit3i 1Yate G4 LT f+1 } /•?Ptc"t rU'IC�o�i'e:!i y/with iCON-1 Liebert unit. e Gs grange Wires Cooling Uri, Livumrr.''l9ini-fwtta`.e 1-711110 fi) Z ao 5 ton? T61 LT410 0 to 5 ton) Orangevdires CaoEir:y Unit L_ebter t'CRV E_"i"ZOG IVtCd;Urn.-er:troI Board' l"tat LT410 Lieber,`CRV Transformer LT410 Orange wires cooling Unit TB1 Red �- C From 24V Transformer Red LT410 Liebert"I contact monitor panel Yellow Wires Alarm Panel 2-NC • 2-COM Input Contact 2-NO (N.OJ Vertiv.com I Vertiv Headquarters,1050 Dearborn Drive,Columbus,OH,43085,USA (i)2020 Vertiv Group Corp.All rights reserved.Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp.All other names and logos referred to are trade names,trademarks or registered trademarks of their respective owners.While every precaution has b:)en taken to ensure accuracy and completeness herein.Vertiv Group. Co.assumes no responsibility,and disclaims all liability,for damages resulting from use of this information or for any errors or omissions.Specifications are subject to change without notice. SL-31050 Rev3_07-20 4 Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV. LIEBERT MC CONDENSER PREMIUM EFFICIENCY CONTROL STANDARD & OPTIONAL FEATURES STANDARD FEATURES COIL Liebert microchannel coils are all-aluminum construction.Tubes are created by extruding small parallel refrigerant flow paths into aluminum. Full-depth louvered aluminum fins fill spaces between the tubes. Tubes, fins and aluminum headers are oven-brazed to form a complete refrigerant-to-air heat exchange coil.Baffles are used in the headers to separate one coil slab into multiple passes as needed.Coils are factory leak tested at a minimum of 300 PSIG and dehydrated. Copper stub pipes are electric resistance welded to aluminum coils and joints are protected with polyolefin to seal joint from environmental corrosive elements. Hot gas and liquid lines are brazed to the stub pipes with spun closed ends for customer piping connections.Coil pipe assembles are filled and sealed with a nitrogen holding charge for shipment.One coil is used per fan assembly. FAN/MOTOR ASSEMBLY The fan/motor assembly is complete with external rotor motor,fan blades and fan/finger guard.Fan blades are constructed of stamped aluminum or steel extrusion coated with PP plastic.Fan guards are heavy gauge,close meshed,steel wire,coated with a black corrosion resistant finish. Fan terminal blocks located on the top of the fan guard with IP54 protection class.Fans are factory balanced and tested before shipment. FAN MOTORS Fan motors are specifically designed for variable speed and have ball bearings.The EC fans provide internal overload protection through the built-in electronics.Each EC fan motor has built-in controller and communication module,linked via RS485 communication wire to each fan and the Premium Control Board.This allows each fan to receive and respond to precise fan speed inputs from the Premium control board. PREMIUM EFFICIENCY FAN CONTROL The Liebert premium efficiency condenser control system is complete with control board, EC fan motor(s),refrigerant-pressure transducer(s), refrigerant-temperature thermistor(s), ambient-temperature thermistor, and motor overload protection in the factory wired control panel.The control board maintains EC fans on the same circuit to the same speed in order to maintain refrigerant head pressure.The control board receives a run signal from the compressor of the indoor unit via field-supplied low voltage interlock wires and field-supplied CANbus communication wires from the indoor unit iCOM.The control system provides refrigerant head pressure and system starting for outdoor ambient temperature as low as -30°F (-35 °C), provided the total temperature design range (from minimum to maximum)is 125°F(70°C)or less. HOUSING The condenser housing is constructed of bright aluminum sheet and divided into individual fan sections by full width baffles. Internal structural support members,including coil support frame,are galvanized steel for strength and corrosion resistance.Panel doors are provided on two sides of each coil/fan section to provide for coil cleaning.Aluminum legs are provided with rigging holes for hoisting the unit into position. COMMUNICATION The Premium Efficiency Control communicates with the iCOM control of the indoor Liebert unit using field supplied CANbus wires.The communication link allows for condenser alarm condition communication to iCOM,communication of other measurable items on the condenser,and fan control features to improve efficiency,sound and wintertime operation based on iCOM programming. UNIT DISCONNECT SWITCH Locking unit disconnect switch is factory installed and wired in attached condenser control section. OPTIONAL FEATURES LIEBERT LEE-TEMP LOW AMBIENT CONTROL Lee-Temp receiver kits can be added to achieve head pressure control down to minimum ambient temperatures of-30°F(-34°C).The premium efficiency fan control when used with the Liebert Lee-Temp receiver kits runs the fan(s) at lower speeds during cold temperatures saving fan energy. 575V POWER SUPPLY The factory installed condenser option will include a secondary enclosure,a 575V-tc-480V,3 phase,step down a-ansformer, secondary fuses for the.transformer.and all wiring between the main and secondary electrical enclosures.Site power connections will ne made in the main electrical enclosure and rhe secondary enclosure will be located on the condenser end opposite of the main electrical enclosure. E-COAT COIL PROTECTION The aluminum microchannel coil is epoxy-coated for extended coil life in corrosive environments,such as coastal areas. Factory-applied E-coat using immersion and baking process provides a flexible epoxy-coating to all coil surfaces and ensures complete coil encapsulation. Coil color is black and a factory-applied UV topcoat protects the E-coat from solar UV ray degradation. DPNO02155 REV: 4 g Page:1/1 REV DATE: 8/19 U2. Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV. LIEBERT MC CONDENSER CABINET & ANCHOR DIMENSIONAL DATA 1 FAN (MC5028, MCM040, MUM) 5/5v- Opficn 575V �F r QpllOfl H _ TOP OF ,' • • FAN GUARD o G o-� O � a A 0 0 •o A' With Receiver Option C Entering Hot Gas and Leaving Liquid Piping © b' _ o A ! ! o. Main °' - Anchor Electric M L K ® ° Plan Box End I 0 1 6112" Ref. (165mm 1 Ute— 15114" K �3 ' Left Side of Unit l 387mm) 35/8" Front View(Lee-Temp Shown) (93mm) (21mm) Typ' �(48mm) Typ. Typ. LIEBERT F in.(mm) MODEL (LEG HEIGHT DIMENSIONS) (178rr{m) NUMBER 18(IM - 31(9.14)-._-_j_ 48('.219) 60(152-4) Typ, MCS028 -- -- --.1 L" la1 C W,NO DIM'G" 31-5/8(803) 435`811'f01 i31-5'8('r51) 72-5'8(`•87("; ` DIM°H" 39-5/8(1006) 1 57-5'II i(4642- ( tiJ 5'8 7682- 81 5B 1,'2073) DETAIL A 1/2"(13mm)x 1"(25mm) - " -- - — ;�1CLo�� Obround Typ. - ---- - - Typical all legs UIP:! 'G" r'8(9 i? 53 7 8 11 63; 1 557:8 2-'6 3S '-7 Note; 43-58— I_« r,,.,:, -- " i;i10F1r ti`-'S( 1565) � 0o0 1 S� UiF 'H 1. Liebert recommends a clearance of 36"(915mm)on 2.each side for proper operation and component access. 2. Cross Bracing required for legs longer than LIEBERT A in r7mi 18"(457.2mm).Quantity varies per model&options MODEL A in(mm) ( C in(mm) D in(mm) K in(mm) L in(mm) M in(mm) selected. 11575V ONLY) 3 For PDX w/EEV systems&unheated refrigerant NUMBER receivers,6-1/2"(165mm)is 9-1/4"(235mm)and MCS028 50-5/8(1287) 58-7!8(1495) 44-1/8(1120) 42-1/2(1080) 42-1/2(1080) 40-7/8(1038) 35-7/8(910) 15-1/4"(387)is not applicable. a MCM040 4ai) 653/8(16-61), 48(1219) 46-516(1!7,. 46;2- 168) 4 57-3' 16(1 4-3'8(1127.09-5,1609) $a MCI 055 68(17271 77(195b) 5�(1 422) 54 ir8(13811 5`5-_; l"4101 53 '8(1366;i 48 P1238) DPNO03436 REV: 2 Page:1/1 REV DATE: 12/16 Document generated 16 September 2022 03:00 PM (EST). ti0 VERTIV. LIEBERT MC CONDENSER CONDENSER AND OPTION WEIGHT DATA, lb(kg) Size Small (MCS) Mediiii ( iCM) Condenser Model MCS028 MCS056 MCN11040 MCM080 MCM160 Refrigerant Circuits 1 2 1 1 2 2 18"Leg 1 154 (70) 270 ( i 22) 231 (' 105) 441 (200) 441 (200) 880 3910) Condenser Dry 36"Leg I 286 130) 1 419 190) 363 165) 590 (268) X590 (268) 1 1066 484'.. 318 14 4, 451 205) 395 ( 179) 622 8-2) F Weight 48"Leg ? 2Q2, 60" 12 1114 f 1, Y. 60"Leg 349 15 8) 432—(219) ( 4 26 ( 19'3) j 653 2961 i 653 2961 1160 526.; Additional Weight for Options PDX-EEV Receiver 45 20) 45 120) 45 20) 51 220 1100) Lee-Temp 5 110 (50) 55 251, 1 DSE Receiver DA050/080/085 90 (4 -6-13—ffe­ce1vCr DA1 25/150/165 92(42) 13:1 (8311 575V Transformer 5 2�) 65 29) 60 27) 70 3 2) 70 32) 80 361 ----------- Coated Coil 4 (2) 8 41 5 2) 5) 0 5) 20 9; L u'isroiclIA/ind Bracing 118"legs41 I 40 IF) 40 ( 18) 40 18) 40 18) 57 2f,i J_ Size Large(MCL) Condenser Model--- MCI-055 A N16-L,10 MCLI 65 Refrigerant Circuits I 1 2 1 1 2 18"Leg 344 156) 602 273) 1 891 404) 1186 (538) 7-186-7(—538) Condenser Dry 36"Leg 486 220) 766 347) 1 ! 766 515) 1453 659, 14153 659) -4-87'Leg 518 23155) 7H 36122-1) 17798 362) 1184 53 7, 1501 6811 '501 681' weight J"f j --R-9 3-6) 82 —123;-07 —15 4—1 (-702k 60"Leg 549 249) _,-547-(702) Additional Weight for Options PDX-EEE Receiver 45 (20) Lee-Temp 60 27! 115 521 120 (511) 175 791, 215 (98) 240 10 DSE Recaiver DA05010W-085- -' '-----4-5 c0) 90 (41) 45 5 20) 4 .......... )SE Receiver D Al 25150/165 94 43) 94 43) 94 i 43) 132 85; -1 (30) 77 05) 77 (35) 118 118 54) 118 54) 5 5VTronsformar 54) Coated Coil 8 (,4) 16 ( 7) 16 7) 24 I 1) 2 15) 32 15%; — 4-1 19) 5,,�isajk-A,Uind Bracing 40 ( 18) 40 �' 18) 57 26) 57 26) 57 26; Total weight is the sum of'Condenser'+('PDX-EEV Receiver'or'Lee-Temp'or'DS E Receiver 050/080/085'or'DSE Receiver 125/150/165)'+'Coated Coil'+'575V Transf ormer'.+'Seism1cffiFind Bracing' DPNO03034 REV: 4 Page:1 /1 REV DATE: 4/18 Document generated 16 September 2022 03:00 PM (EST). A VERTIV. _ LIEBERT MC CONDENSER PIPING LOCATIONS SINGLE CIRCUIT WITH LEE-TEMP HOT GAS LINE TO CONDENSER ENTERING HOT GAS LINE COVER' I _ m \ I I ® � B VIEW ® I I I I I I II t METAL CLAMP ISOLATOR POSITION ELBOW TO B VIEW FASTEN HOT GAS LINE TO CABINET DIRECT RELIEF VALVE USING FLAT SURFACE CLAMPS WITH DETAIL A DOWNWARD ISOLATORS(FIELD SUPPLIED) SEE DETAIL A-A = _ = FIELD PIPING LEAVING LIQUID LINE LIQUID LINE FROM CONDENSER GENERALARRANGEMENT i LIEBERT SUPPLIED PIPING ASSEMBLY WILL INCLUDE 1 TO 3 HEAD PRESSURE VALVES AND CHECK VALVES DEPENDENT ON CONDENSER CAPACITY AND REFRIGERANT. NOTE: 1.THE FOLLOWING MATERIALS ARE SUPPLIED BY LIEBERT,SHIPPED LOOSE FOR EACH CIRCUIT AND FOR FIELD INSTALLATION: INSULATED LEE-TEMP RECEIVER TANK WITH ELECTRIC HEATER PADS AND SIGHT GLASSES,PIPING ASSEMBLY WITH HEAD PRESSURE CONTROL VALVE AND CHECK VALVE,ROTO-LOCK VALVE AND PRESSURE RELIEF VALVE.ALL OTHER PIPING AND ELECTRICAL WIRING TO BE SUPPLIED AND INSTALLED BY OTHERS. ADDITIONAL CONDENSER LEG PER CIRCUIT WHEN REQUIRED,SHIPS WITH THE CONDENSER. CONDENSER PIPING CONNECTION SIZES CONDENSER CONNECTIONS (ODS-INCHES) LEE-TEMP CONNECTIONS CONDENSER HOT GAS TEE LIQ TO L-T VALVE RECEIVER OUT MODEL NO. CIRCUITS HOT GAS LIQUID (IDS-INCHES) (ODS-INCHES) ROTO LOCK (IDS-INCHES) MCS028 7/8 5/8 7/8 5/8 5/8 U1CM040 MCM080i 718 1-118 718 1-11 7118 j fIVICL0355 1 rib "CL110 1-3/8 i-1;8 i•3;18 11;8 1 %8 __ '1CL220 _ 1-5i t-3.8 1.5/ 1-3/88 t 3;8 �._ J ... w_ 'SHIPPING COVER IS NOT NECESSARY FOR PROPER CONDENSER OPERATION AND s MAY BE RECYCLED IF FIELD PIPING INTERFERES WITH PROPER REATTACHMENT. DPNO02167 REV: 7 Z Pagel/1 REV DATE: 12/16 Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT AIR COOLED SYSTEMS RECOMMENDED REFRIGERANT LINE SIZES CU, OD LIEBERT AIR-COOLED SYSTEMS USING R-41 OA System Fluid : R410A Any Compressor Type Indoor Model Equivalent Length 50 ft(15m) 100 ft(30m) 150 ft(45m) 300 ft(91 m) 450ft(137m) CR01 9RA/CR020RA Hot Gas Line,in. 3/4 3/4 3/4 7/8 j Liquid Line,in, 5/8 51118 5/8 3/4 CR035RA Hot Gas Line,in. 7/8 7/8 7/8 1-1,,8 2 Liquid Line,in. 3/4 3/4 3/4 7/8 PX011 Hot Gas Line,in. 1/2 5/8 2 5/8 2 5/8 'I Liquid Line,in. 3/8 1/2 1/2 1/2 PX018 blot Gas Line,in. 5 5 :'8 5/8 118 3/4 2 Liquid Line,in. 1,2 1;2 1/2J-- 5/ Pxa23 Hot Gas Line.in. 3/4 314 3/4 7;8 2 - Liquid Line,in. 5/8 5/8 51/8 5,18 pX029 Hot Gas Line,in. �7/8 7`8 I 7/8 _ 1_1r8 2 _ __ - __ Liquid Line,in. 5118 _5;8_ _5118 3/4 I DA050/DA080/ Hot Gas Line,in. 1-1/8 _ 1-1/8 1.1/8 1-1!3 _ - 1-1 8 DA085 Liquid Line,in. 7/8 7-8 7/8 _7118 7;8-� _.� Not Gas Line.in 1 3'8 3'5- T 1 3/8 1-3!8 1 r8 ' DA125 - --— Liquid Line,ins...-..-_ 7/8�— 7 a 7118 7!8 ^718_ 3� DA150 Hot teas Line,in. 1-3/8 _ 1-3.'8 —� 1.3/8 mm — 1-3'8�- u 1-3,'8 _ Liquid line,in. 7/8 1 1118 1-1/8 1-1/8 11-11'8 DAiti5 Hot Gas Line,in_ � 1-3`8 1-3/8 1-3/8 1-318 _.._ 1-3,`83 3 _ Liquid Line,in. 7/8 1-1/8 1.1118 1.1/8 1-1;8 3 _ Hot Gas Line,in. 15/8 1-5/8 1-5118 `' 1-5/84 DA250/DA265 a Liquid Line,in. 1 orb 1 ,3/8 1 3/$ 1 3/8 �_...__. System Fluid: R410A Digital Scroll Models [f ndcor klodel Equivalent Length 50 ft(15rn) 75 fl(23m) 100 ff(30m) 125 f ;38rn) 150 ft;45ni) MT036 Suction Line,in. 7/8 718 718 718 718 Lia,,uid Line,in. 1/2 1/2 1/2 1/2 1;`2 WOOJ Suction Line,in. 7/8 1-1/8 2 1-1/8 2 1-1/8 21 1-1118 2 Liquid Line,in. 1112 ill %85%8 5/8 ll":71160 Suction Line,in. 1-1/8 1-11/8 1-1/8 _ TV8 _ 1-1/18 Liquid Line,in. 1/2 5/8 _ _ 5/8 5118 Notes: 1.Consult factory for proper line sizing for runs longer than maximum equivalent length shown in table. 2.Must downsize vertical riser one trade size(1-1/8"to 7/8"or 7/8"to 3/4"or 3/4"to 5/8"or 5/8"to 1/2"). 3.Consult factory when actual pipe length between condenser/Liebert®EconoPhase and Liebert®DSE unit will exceed 300 ft(91 m). 4.Liebert DA250-265 unit can be extended to max 200ft(61 m)linear or 300ft.(91 m)equivalent. Z DPN000788 REV: 14 Z Page:1/2 REV DATE: 2/20 r LL Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV LIEBERT MC CONDENSER AIR COOLED PIPING SCHEMATIC CONDENSER ABOVE INDOOR UNIT Liquid 7.6" I - -- 1194mm l Gas - MC Condenser with Receiver Gas (Piping to Condenser&Receiver not shown for clarity) MC CCti`1Ci4r;i spi ,,iA gout RI-ceiver ;Piping to Ocie?en<er",oi Nhot";n for clarity) Notes: I A 1A. Pitch horizontal hot gas piping at a minimum of 60' 1/2"per 10 feet(42mm per 10m)so that gravity will 118.3m l aid in moving oil in the direction of the refrigeration flow. Maximum 2. Single circuit condenser shown. Vertical Rise Indoor Unit Z4 A3. Unit piping entrance varies by unit and may be through the top of the unit. I �4. the unit maybe Liebert DS,PDX,or CRV and Is shown for reference only while demonstrating proper TXV location pipe and unit/condenser height differences. Liquid I 5. The bottom of the condenser coil or bottom of the receiver (If equipped)must be higher than the elevation of the TXV inside the indoor unit. The vertical height must not exceed 60 feet(18.3m). Z . Trapping must be practiced at bottom of riser with any rise over 5 feet high.If rise exceeds 25 feet(7.5m),then a trap is required in 20 fool(6 m)increments or evenly divided I H I 6 I I I GI 6 I 3 Gas - - -Gas I iLiquid 1 Liquid Internal TXV Height H in.(mm) PDX Dawn ow 4, PDX Uplow 20(508) DS035-105 Do�,vn5()w/Up0uw 43(1092) CHV CR019 _-. 45;11x13__ —--— Field piping GRU-CR020 CR035_-- 27rv(Eif36 DPNO03954 REV: 4 Z Page:1/4 REV DATE : 9/19 Document generated 16 September 2022 03:00 PM (EST). A VERTIVti LIEBERT MC CONDENSER AIR COOLED PIPING SCHEMATIC CONDENSER AND INDOOR UNIT AT SAME LEVEL Indoor Unit A4 F0 TXV location o o A I II I H Gas, 1 Liquid I -_ — — I MC Condenser with Receiver ; _ 3 (complete piping not shown for clarity) —--— Field piping Notes: QPitch horizontal hot gas piping at a minimum of 1/2"per 10 feet(42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow. 2. Single circuit condenser shown. AUnit piping entrance varies by unit and may be through Internal TXV H in.(mm)Height the top of the unit. g AIndoor unit may be Liebert DS,PDX,or CRV and i PDX Downflc ., 44(11 18) is shown for reference only. PDX Upflow 20(508 i The bottom of the receiver must be higher than the elevation of the TXV inside the indoor unit,otherwise extended legs or DS035-105 DowMow/Upi1ow 43(1092) a field piped subcooler needs to be utilized. Contact your CRV-CRO19 - 45(1143)- Vertiv sales representative for additional information. CRV-CR020/CR035 27(686) s g DPNO03954 REV: 4 Z Page:2/4 REV DATE : 9/19 11 Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT MC CONDENSER AIR COOLED PIPING SCHEMATIC CONDENSER BELOW INDOOR UNIT Ful -1 i AIndoor Unit--",/ Z�TXV location H I I 3 15' Gas © (4.6m) I Notes: Maximum 5 I I Vertical Drop I itch horizontal hot gas piping at a minimum of 1/2"per 10 feet(42mm per 10m) so that gravity will Liquid aid in moving oil in the direction of the refrigeration flow. 2. Single circuit condenser shown, A3. Unit piping entrance varies by unit and may be through I the top of the unit. A4 Indoor unit may be Lieberl DS,PDX,or CRV and MC Condenser with Receiver 1 is shown for reference only while demonstrating proper Gas pipe and unit/condenser height differences. A5. The bottom of the condenser coil must be less than 15 feet(4.6m) below the location of the TXV in the indoor unit, otherwise extended legs or a field piped subcooler needs to be utilized. Contact your Vertiv sales representative for additional information. 6. This Configuration is not valid for Lieber!MC with Lee-Temp or unheated receiver. {; .............. —--------�.. Gas Liquid Internal TXV Height H in.(mm) PDX Downflow ' 44(1113) MC Condenser without receiver —––— Field piping PDX U flow 20(508) DS035-105 Dow illow,'UpBo i 43 (1092) CRV-CRO19 45(11431 CRV-CR020/CR035 27(636,'^ DPNO03954 REV: 4 Z Page:4/4 REV DATE : 9/19 Document generated 16 September 2022 03:00 PM (EST). 0 VERTIV LIEBERT MC CONDENSER TYPICAL PIPING SCHEMATIC FOR AIR-COOLED DX SYSTEMS a Check Valve Relief Valve ! Gplional Field Insialked Service Head Pressure Fusible Pl�,g Valve Control Valve LIQUID RETURN Pre--ure — — — — Trar sd ter Pressure LEE-TEMP RECEIVER Transducer Check Valve r CC NDLNSLR C01 CONDENSER COIL (Includes ac,ory pruvidod ---I nverled trot;. Na (Includes factory provided external;r1p req:aifcx, r).?.� d g..__ __ inverted trap. No external trap required) LIEBERT MC CONCENS HOT GAS DISCHARGE LIEBERT MC CONDENSER WITH LEE-TEMP OPTION LIQUID r r Sensing Bulb EVAPORATOR COIL A3 SUCTION For rises over 25ft.(7.6m),trap I every 20ft.(6m) I or evenly divided Service Valve Check i,g., Field installed relief valve;s)required Valve Service far 50Hz EU CE units. COMPRESSOR Valve External I Equalizer I HOT GAS DISCHARGE LIQUID LINE Expansion Solenoid Sight Filter Drier Valve Valve Glass INTERCONNECTING PIPING FACTORY REFRIGERANT PIPING 0 SERVICEISCHRADER(ACCESS)CONNECTION NO VALVE CORE —— FIELD PIPING 4 SERVICE/SCHRADER(ACCESS)CONNECTION WITH VALVE CORE �3 Trap at base of risers Notes: 1. Single refrigeration circuit shown for clarity, over 5ft.(1.5m) 2. Schematic representation shown.Do not use for specific connection locations. Components are not supplied by Liebert,but are required for proper operation and maintenance. 4. Traps must be installed and horizontal lines pitched to ensure proper oil return and to reduce liquid floodback to compressor. Pitch horizontal hot gas piping at a minimum of 1/2"per 10 feet(42mm per 10m)so that gravity will aid in moving oil in the direction of the refrigeration flow. 5. Do not islolate any refrigeration circuits from over pressurization protection. DPNO02188 REV: 7 Z Page:1/1 REV DATE: 12/17 lY °Document generated 16 September 2022 03:00 PM (EST). VERTIV. LIEBERT MC CONDENSER ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP Electrical Connections for Lee-Temp Receiver Lee-Temp receiver tank(1 per circuit). FAN2 NOTE:Heater pad voltage available for FAN1 120V/1 phase/60 Hz or 230V11 phase/60Hz O 150 or 300 Watt,varies by condenser. 0 Electrical connection box with cover. . o O � (Cover removed for clarity.) m a Electrical service connection.Pigtails in electric handy box are factory wired to Lee-Temp heater pads for field connection of separate continuous electric source,wire not by Liebert. 0 0 0 o ® ® o 0 0 0 0 0 ® ® m ® ® w o p 5C o . •— —• 0000po ° 7. --�� sss — — 0 °0000 (LEFT KNOCKOUT) (RIGHT TWO KNOCKOUTS .8. IO 9. iin�ie.�.ia' o cn'�a.rre KEY ELECTRICAL DETAILS: 1) Three phase electrical service—Terminals are on top of disconnect switch for one and two fan units.Terminals are on bottom of disconnect switch for three and four fan units.Three phase service not by Liebert.See Note 5(below). 2) Earth ground—Field lug terminal for earth ground connection.Ground terminal strip for fan motor ground connection. 3) Primary high voltage entrance—Two 7/8"(22.2mm)diameter knockouts located at the bottom of the enclosure. 4) SPD field connection terminals—High voltage surge protective device(SPD)terminals.SPD is an optional device. $ DPNO02374 REV: 9 Z Page:1/3 REV DATE: 2/17 11 Document generated 16 September 2022 03:00 PM (EST). A LIEBERT MC CONDENSER VERTIV ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP 5) CANbus terminal connections—Field terminals for CANbus cable connection. •5A is the CANbus connectors. o TB49-1 is the input terminal for CANbus high. o TB49-3 is the input terminal for CANbus low. o TB50-1 is output terminal for CANbus high. o TB50-3 is the output terminal for CANbus low. o Each CANbus cable shield is connected to terminal"SH",item 9. •5B is the"END OF LINE"jumper. •5C is the CANbus"DEVICE ADDRESS DIP SWITCH".CANbus cable not by Liebert.See Note 2(below). 6) Remote unit shutdown—Replace exiting jumper between terminals TB38-1 and TB38-2 with field supplied normally closed switch having a minimum 75VA 24VAC rating.Use field supplied Class 1 wiring.(This is an optional feature that may be owner specified.) 7) Alarm terminal connections— a. Common Alarm Relay indicates when any type of alarm occurs.TB74-1 is common,TB74-2 is normally open,and TB74-3 is normally closed. 1 Amp 24VAC is the maximum load.Use Class 1 field supplied wiring. b. Shutdown Alarm Relay indicates when condenser loses power,or when a critical alarm has occurred that shuts down the condenser unit.TB74-4 is common,TB74-5 is normally open,and TB74-6 is normally closed.1 Amp 24VAC is the maximum load. Use Class 1 field supplied wiring. 8) Indoor unit interlock and SPD alarm terminals— a. On any call for compressor operation,normally open contact is closed across terminals 70&71 for Circuit 1,and normally open contact is closed across terminals 70&230 for Circuit 2 from indoor room unit. b. During SPD alarm,normally open contact is closed across terminals 12&13.SPD is an optional device. 9) CANbus shield terminal—Terminal for field connection of the CANbus field supplied cables.Shield of CANbus field supplied cables must not be connected to ground. 10) Primary low voltage entrance—One 7/8"(22.2mm)diameter knockout that is free for customer low voltage wiring. 11) SPD entrance—One 7/8"(22.2mm)diameter knockout hole located at the bottom of the enclosure.High voltage surge protective device (SPD)is optional. NOTES: 1. Refer to specification sheet for unit voltage rating,full load amp,and wire size amp ratings. 2. The CANbus wiring is field supplied and must be: - Braided shield or foil shield with drain wire - Shield must be wired to ground at indoor unit - 22-18AWG stranded tinned copper -Twisted pair(minimum 4 twists per foot) - Low Capacitance(15pF/FT or less) - Must be rated to meet local codes and conditions - EXAMPLES BELDEN 89207(PLENUM RATED),OR ALPHA WIRE 6454 CATEGORY 5,5E,OR HIGHER 3. Do not run in same conduit,raceway,or chase as high voltage wiring. 4. For CANbus network lengths greater than 45OFT(137M)call Factory. DPNO02374 REV: 9 Z Page:2/3 REV DATE: 2/17 lL Document generated 16 September 2022 03:00 PM (EST). A VERTIV LIEBERT MC CONDENSER ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP 5. All wiring must be sized and selected for insulation case per NEC and other local codes. 6. Do not bend cables to less than four times the diameter of the cable. 7. Do not deform cables when securing in bundles or when hanging them. 8. Avoid running the cables by devices that may introduce noise,such as machines,fluorescent lights,and electronics. 9. Avoid stretching cables. 10. The electrically commutated (EC) motors included in the Liebert MC Condenser are suitable for connection to power supplies with a solidly grounded neutral or high resistance to ground or corner ground. A.Acceptable power supplies for 208 to 575V nominal units: • 208V wye with solidly grounded neutral and 120V line to ground; • 380V wye with solidly grounded neutral and 220V line to ground; • 480V wye with solidly grounded neutral and 277V line to ground; • 575V wye with solidly grounded neutral and 332V line to ground(uses step-down transformer); • Wye with high resistance(or impedance)ground; • Delta with corner ground B.Unacceptable power supplies for 208V to 575V nominal units: • Delta without ground or with floating ground; • Delta with grounded center tap. DPNO02374 REV: 9 Z Page:3/3 REV DATE: 2/17 0 LL i 8 7 6 5 4 3 2 1 _ 5]SvfF>:nmWuuR —, 431 �',--n, ew sst NOTES: ql9®p6WaSCf -- to pOwEaBIpIX UFT_ / L EC TAPS HAVE NTEANALOVERLOAD PROTECTION DEVICES s eoz ssz 2.MOTORSPROTECfID FOR PRIMARY SMGLEPHPSECONDITIONS I 3R E IW I �T TERMNN 3.CONTROL VOLTAGE TRANSFORMER PR MRR TAP IS DEPENDENT TIKTAGE �- BK art 49-300- —�— 0NUNEVOLTAGE SEELABELONTRANSFORhER 6YODFAs U o ff' I L 644 4 SPD[SAM OPRONALFIEID INSTALLEDDEVICE 5ffnolEnRe u' r.�SH t�tElu�F S MAID RMAREONCY PROVIDED IN DUAL CIRCUIT UNITS. 5 I I 49.1 0 - 'A, V: 646 5 6 FAN l AND ROT ARE CONNECTED FOR ONE FAN CONDENSERS. EaRTxGxm ND 1�0D^Wl 7.FAN!-FAN2 AND RCI-FC2ARE CONVECTED FOR 2 FAN UMTS [ONDE7581 zi epz 666 4 FAN1-FANS AND FCt-FC3ARE CONNECTED FOR 3 FAN UNITS --- y 1 H2 FC4 X1 X2 X3 PRE 49.30 —`h3 F14 54] 9.FAN7-FANO AND FCI-FCq ARE CONNECTED FOO4FAN UMTS D I - I n4 BaE 11. SECONDSET OF JUMPER FOR�MD RSB RMINALSHUTDM PSIIS PRESENT D ww ,s, mpg na s+l [TEEIUANAS riff CO�MXUSE ARIICAnONSECOND TO THE } 1 FAN IN THE ORDER 10 OurPUr, tN rH�VAm Aa sF2 10 12 CONVECT ORDER PAIR SHIELDEDCABLEIF ED) Jh� t5J Fra su FROM UEBEAT INDOOR UNTTTOP49PIPUTTERMINALS APD V I OJIRR2 ts. 414 6H FROM P50 OUTPUT TERM! TO SECOND CONDENSER OR TO PRE OPTION AS SHOWN.IF CONNECTING CAN COMMUNICATIONS 5rsv.'W+mataww.FR I7aIDsi re I SEENp1E3 T, 13. FINAL ONLY NOT TO m STRANDED CABLE MST SHIELD OF CABLES TO SH EwSHELDED,244-16AWG q----ONr E, STRANDED TIMED COPPER,TVASTED PNRIMNMUM 4 TWSTS 15 ———————————J zdt a � w z14 15 Pf:fl FOOT),ION CAPACRANC RATEDF R LE551•MUST BE ---u mmroscr --- roa1=aBIttK VOLTAGEAtmTFMPEAATURE R4TED FOO COmITION3 PRESSE. -` FOO CANBUS NETWORK LENGTHS GREATER THAN 350 10 tP1IN4 1m), YOLTAOESIOPLY -u ESR 3A 3A CONTACT UEBERT FACTORY.00 NOTflUN WiDi HGH40LTAGE HIRE BrorlFTs u ' �' NOMENCLATURE 8R RSfD ELSLWAERONBWSCCROPTDN 7 } T7— ATS THEIR STOR-OUTDOOR AMBIENT 46 „FaRBOROMD suROEPRT1Ec1pN,-T $1 31 20—FB FSEBLCDK FOR 576VMIER SECONDARY 1 D�.WOI '-i-} FR2d FTSE BLOCKFOR FAN2-d 31,36,41 �_.-_._..___.. J—N J 192 FC1-4 FAN CONTACTOR I-4 23252729 a� t0 —�(9Qe Sff ND1ElJ --- l3 12 L, Sff 101Et0. FAN-4 EC FAN MOTOR I-4 -1,36,41 36 CMIBUS-OND OF UN'JUMPQi(CIRCUT EXMRDJ 54.570 _�Y1.___-- Of 331 R FCI wu2 b COMMON RELAY,30V 1NA MAK FORM C 49 r��+ B9MUSEDW E 97 K4 SMITDOWNALARM RELAY,30V 1LAMAX FORM 49 C 1 SFEtpTEtt. FC YfBM1H1�—1fAN11Ni$ MRBIRBI FUSE BLOCK FOR FAN 1 25 C Lar i i BIt1 Fo— nt R��w 9a _,R 25 as 4 FAN ENOTORURE TII4 CCMPGTOfl 7RIFG 1d 234,752729 } R5 Er RTSI REFSPARIGERANTTI.2TPoAC39,40 'v N--� RTSI-2 SURGE EROTECTI NDEVI R-CDICLTTI-2 42,44fun BK3�� zgt R Fp w 204 X971 SPD CANBUSRDTECTKIN DEVICE 2 S CANBLSADORESS gPStiVRCH(CIRCUfffX1AAD) 55,5561 gENpB 11, Ti CONTROL XFMFA 14 = ftn 6k 2s, a FCs w zsx agllAx T7 CONTROLBOORDSOLATICNXFMER 2D 30 I SKI_I U7 SPO-INPUT ADDnXWL_ 37 L12i fS4� BK2�� �N_0 BK 11d US 5 REMOTE SMRDOAN2 SO4AL 26.35.31.33 �� U6.7 COMPRESSOfl SIGNALCIFICUTT I-2 3231 3 rx 13 I Fm BK3�i� F--6 ,t-] 4FLUTBOMDPLUG AND TFAMNALASBGNMENB SFE ,t. r OR ,la 18136133-SPDA ryWi$ 1850-LANBII61011M:NEXTDEMCE SFENI4NEDiKN tta %5-axuN0 Dt0YpOQ11%lrE P%_m 35 I Wt---�iF�—BK BK I DEFNswnN 71 I %]-PRESSURE TRVWWO Z cwaRl W-UAZE WRAC 0=ff zFC3 94]OORPOOY ,H 3$ Pts-PRFSSIflE1RaP50110ERF0a CWO4T2 1851-SPPRETRRCOUIPUT plts—oiM�BR BK I Tam EElaN. — IR to rm:T Bio P&Iir PoarnLl �.wdWSs�utcErFJwwu >VA 141 PJ( O--P B! 114 Ptl-R6RNSTI CARFORCMM2 TBA.]169D-Dd)O]fl CQ.1P9GW1 } 6163�{I.0-8K P9-TRMCOIfTPUr PoRFANI 1814-MARY RELAYS L J PN-HVACDNII.PIIt 1819-RSO TDFAZ } SFE 811, %p.TRMCWIRIr RO F- 1880-RSffiSE 1FAZ I 1W F8a �1 56x lU:U%COU�FCAF W TBBI-SPME R516ro FNS B 'ERE a a nx 40 lam-RFwTESARDOWN B ac b RSB. W2 a xt FAG1analPRlmlpEttlTfGEWWS } FANI BK3-���R P 17-2 R Pfl lAl At OflB10 Aa FACIp1Y51Wg1®N,¢TMRrG RBDSMgIDHYtl.T,wSG 81 Al CUAR¢EpfYmpIEWYLWgc-NV¢T INS 2M oRi62o HQ "'W,LFNOOENLES FlDIDEDINOFlILOS R A '61 W FIECIRpbOSWfppRNL10,018 45 P12 1st SFE N3BS 45 I4II�dlD(ttSWNNEtf g6 ]99 RS4S 83 R- 191 O AT9 O 193 D O PIGRR+Mf�e�40 841 SEENpBi ® O lEY4NNBDIXCQdECIpNONCORR6BD9FD Atx V 161 p H IM COT El 1WLW]E�WYIFLTONttIEIFfBa4D6 w9iNG No142 K1 S4MrD0AT1 145 49 SQ Q GPd.TOCingRll OE1ECi0a DRD4T FEIAY Ki AIARN IM 50 ]� R°AY 146 50 NFE4a— y ------------------------------ --------------------------- DR. —P.yRRE �.� --- .pro,f4.F� ONEINDOOR UMTWITHONECONDENSER I ONE INDOOR UNIT WITH TWO CONDENSERS CONDENSER ONE "-"4tE VERTIV. �Q 1 iEoa ---- iJ j CAN 55 4" SCHEMATIC a � 70 a 71 I CQNO]BN6EL12 �"`� 55 71 q"'03"�°'"'01� A 70 D, 71 7, FiOVEAANHBEWEL „,� a IE e e ,�R , �� � PREMIUM MODEL A {�-_ �E---- - a Z9pNAY IF=I3 PRE.S"MIN y�Js I �' I Y:E��O>It,1a,IC=- 1-4 EC FANS D�EaTRDO.. O p3 I 230 I CONDENSER TWO weo�nOal w 22��QQ I F--2{e Ti 0— 230 MICROCHANNEL i---{0J 0 I uE mr NDoalRoa4uNIr L --_—T 0 _—J J6 G �� °""m"'1° CONDENSER 60 °®QiTB'900R1�0'"1"di I `` 1 5 60 "XE"E'L •tvt� 208/230/380/460/575V 2 OR 3 WIRES ROD SUPPLIED 3WIRESRELDSUPPUED vaNNa °`"tv,6Me AND SPED NOT TO EXCEED 1 AND SPED NOT TO EXCEED I IF CCNDFHffR T IA6fDEVICE VOLT DROP. I VOLT DROP. burp PyE.sxus3, ar dulroLDaEH m,606 300291 15 8 7 6 5 4 3 2 1 FOaMNG,e0A5 REV1 REFERENCE ,• j a 6.2 Liebert NIC Electrical Power Requirements Table 6.3, below lists the power requirements by model number.Table 6.4 below lists the additional electrical requirements if your system includes a Liebert" Lee-Temp"'Receiver. Table 6.3 Electrical data,three-phase,60Hz condenser,Premium EC-fan Control .•. 208/230V 3.0 3.8" 15 380V MCS028 460,V 1.4 1.8 15 575V 1.2, 7.5 15 208/230V 2.3 2.9. 15 , 380V MCM040 460V 1.4 1.8 15 575V 7:2 208/230V 4.6 '5.2 15 380V 2.8 3:2 MCM080 460V 2.8 3.2 15,. 15, 208/230V .• 5.7 7.1 15 380V 2:8.,. 3.5: MCLO55 " 460V 2:8. 3.5 q 15 . 575V . . ..2.3 1. FLA=Full Load Amps;WSA=Wire Size Amps;OPD,.=Maximum Overcurrent Protection Device. Table 6.4 Electrical data,Lee-Temp"receiver,60Hz Watts/Receiver 150 150 Amps. 0.7.:. Wire Size Amps 1.8 0.9 Maximum Overcurrent:P"rotectjon Device. Amps:.,. 1. The LiebertO Lee-Temp receiver requires a separate power feed for heaters. 2. 'The condenser is not designed to supply power to the receiver heater.pads, 3. The Liebert Lee-Temp system allows system start-up and positive head pressure control in outdoor temperature as low as-30°F(-34°C). 46 Vertiv I Liebeacl PDX`and PCW"System Design Catalog 'Document generated 16 September 2022 03:00 PM (EST). VERTIV LIEBERT PDX CANbus & INTERLOCK CONNECTIONS BETWEEN PDX UNIT & LIEBERT MC CONDENSER (PREMIUM) CONNNECTlTlON8 0 • TS50 0• D .n J6 TERMINATION JUMPER ourPur " e®, ®• • '� MUST BE SET TO PINS 1 AND 2. CONDENSER m WP"TB49 a • CANbus V ADDRESSING SWITCH o DETAILt CAN CABLE CONNECTION(A) SHIELD CONNECTION FACTORY WIRING BETWEEN MC CONTROL BOARD AND B A s" TERMINAL STRIP, A HEAT REJECTION INTERLOCK WIRE 70 CANbus CABLE CONNECTION 71 I LOW VOLTAGE FIELD ENTRANCE B 230 LOCATED ON BOTTOM LEFT OF CONDENSER ENCLOSURE. HEAT REJECTION INTERLOCK(B) INDOOR UNIT o� — —��; �r�mmr�qq• ❑ 1 U❑ ❑ N00 (01 ❑ I B g ylgj�$i eo e:n6 rn ® wu rn U [1A ❑❑ ❑U A (OIl OWD ❑ OWO CO ? ❑ A m V O O V ❑ ❑❑ ❑ tD 1@1 11 0 CNJI a Z N 1W1 0 ❑ glu - O O ❑ O O El El❑ ❑ PARTIAL VIEW SHOWN FOR CLARITY DPNO03266 REV: 3 Z Page:1/2 REV DATE: 5/17 f ,6 y Document generated 16 September 2022 03:00 PM (EST). A VERTIV� LIEBERT PDX CANbus & INTERLOCK CONNECTIONS BETWEEN PDX UNIT & LIEBERT MC CONDENSER (PREMIUM) COMPONENT NOTES: 1.COMPONENT APPEARANCE,ORIENTATION AND POSITIONINGMAY VARY TERMINAL NAMES AND CALLOUTS REMAIN CONSTANT. 2.ALL CIRCUITS TO THESE CONNECTION POINTS ARE CLASS 2. CAN&CABLE NOTES(A): 1.CABLE MUSTHAVE THE FOLLOWING SPECIFICATIONS: BRAIDED SHIELD OR FOIL SHIELD WITH DRAIN WIRE -SHIELD MUST BE WIRED TO GROUND AT INDOOR UNIT 22-18AWG STRANDED TINNED COPPER -TWISTED PAIR(MINIMUM 4 TWISTS PER FOOT) -LOW CAPACITANCE(15pF/FT OR LESS) -MUST BE RATED TO MEET LOCAL CODES AND CONDITIONS. EXAMPLES BELDEN 89207(PLENUM RATED),OR ALPHA WIRE 6454 CATEGORY 5,5E,OR HIGHER. 2.DO NOT RUN IN SAME CONDUIT,RACEWAY,OR CHASE AS HIGH VOLTAGE WIRING. 3.FOR CANBUS NETWORK LENGTHS GREATER THAN 450FT(137M),CONTACT FACTORY. INTERLOCK WIRE NOTES(B): 1.FIELD SUPPLIED WIRE -2 CONDUCTOR 18AWG OR GREATER -RATED 600V 2.RUN FIELD SUPPLIED WIRES BETWEEN THE INDOOR UNIT AND THE CONDENSER. i 0 DPNO03266 REV: 3 Z Page:2/2 REV DATE: 5/17