Loading...
HomeMy WebLinkAbout48129-Z x O�g�FFOIKCA- Town of Southold 1/27/2023 dam. P.O.Box 1179 0 o _ t 53095 Main Rd 4,1 �o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43797 Date: 1/27/2023 THIS CERTIFIES that the building GENERATOR Location of Property: 2790 New Suffolk Ave., Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-9-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/28/2022 pursuant to which Building Permit No. 48129 dated 7/28/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Norris, Susan of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48129 1/6/2023 PLUMBERS CERTIFICATION DATED ut or' d Signature ��o�osu FE Qt TOWN OF SOUTHOLD o�y BUILDING DEPARTMENT a TOWN CLERK'S OFFICE SOUTHOLD, NY � BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48129 Date: 7/28/2022 Permission is hereby granted to: Norris, Susan PO BOX 66 Mattituck, NY 11952 To: Install generator to an existing single family dwelling per manufacturer specifications as applied for. Maintain minimum setback of 25 feet. At premises located at: 2790 New Suffolk Ave., Mattituck SCTM #473889 Sec/Block/Lot# 115.-9-4 Pursuant to application dated 6/28/2022 and approved by the Building Inspector. To expire on 1/27/2024. Fees: ACCESSORY $100.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $85.00 Total: $235.00 Building Inspector pf SOUI��I � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �e sean.devlin(pDtown.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Susan Norris Address: 2790 New Suffolk Ave city:Mattituck st: NY zip: 11952 Building Permit#: 48129 Section: 115 Block: 9 Lot: 4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Standard Electric License No: 43098ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 60kW Kohler Generator w/400A Transfer Switch Notes: Generator Inspector Signature: Date: January 6, 2023 S. Devlin-Cert Electrical Compliance Form OF SOUlyolo / 2 f 1 O Re-tvS( f # TOWN OF SOUTHOLD BUILDING DEPT. �o • �o `yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: C✓ Age- DY' A��,J.-- r, /egt- 44 C- k,, CT Av d e 1 Q ttlAeA dotia 'c DATE C 27/ INSPECTOR V' IV SO - - 1 TOWN OF SOUTHOLD"BUILDING DEPT. IOU beau 631-765-1802 INSPECTION FOUNDATION 1ST ROUGH PLBG. FOUNDATION 2ND INSULATIOWCAULKING FRAMING /STRAPPING FINAL FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) *[c-,- IA ELECTRICAL (FINAL) CODE VIOLATION L.?1pPRE C/O RENTAL REMARKS: DATE — INSPECTOR 7z�_ I` so `v TOWN OF SOUTHOLD BUILDING DEPT. cnurm, 631-765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CA�ULKING [ ] FRAMING /STRAPPING [ FINAL bQ,��/i�'+4 � [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �lL Z C 04 - "-A�4 DATE ?i INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ---------------------------------- FOUNDATION(2ND) 900 J ' O y ROUGH FRAMING& PLUMBING y 1 r INSULATION PER N.Y. y STATE ENERGY CODE '14r 0 loll . c� FINAL AD ITIONAL COMMENTS O Z m b � y � O x d b y ,,off°suFFoi �oG° TOWN OF SOUTHOLD—BUILDING DEPARTMENT n y�` Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny_gov Date Received APPLICATION FOR BUILDING PERMIT ,Q For Office Use Only ® PERMIT NO. v I Building Inspector: JUU II ` - N 2 8 2022 2 Applications�and forms must-be filled out in their entirety.Incomplete Do applications will'not.be accepted. Where the Applicant is not the owner,an BUILDING DFPI: Owner's Authorization form-(Page 2)shall be completed. TOWN OF SOUTHOLD Date: OWNER(S)OF PROPERTY: Name: SCTM#1000- r _ Project Address:2790 New Suffolk Ave. Mattituck, NY 11952 Phone#: 6 3 1 '7, Email: Mailing Address: CONTACT PERSON: Name:Chris Tyndall Mailing Address:285 Pulaski Street Riverhead, NY 11901 Phone#:(631)831-8569 Email:ctyndali@commanderpowersystems.com DESIGN PROFESSIONAL INFORMATION: . Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Standard Electric Corp Mailing Address:6500 Jericho Tpke, Suite 22E Syosset, NY 11791 Phone#:(516) 499-7354 Email:cbrutto@standardelectriccorp.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 2 Other install new Kohler 60 KW standby generator(LP) $39,500.00 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes j"o IF YES, PROVIDE A COPY. CR Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by . Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,.County,New York and"other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In buildings)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law: Application Submitted By(print name): kQ,v I h C Ccs ll 11 t r5 iRAuthorized Agent ❑Owner �'e-ev{', Signature of Applicant: Date: Q-V (-2 STATE OF NEW YORK) SS: COUNTY OF SA fOI V— ) k V 1(n Cil IcL-6::- c Ve-- being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contra r,Agent, rporate Officer,etc.) of said owner or owners,and is duly authorized top mor have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 30 day of 1U(Y-- ,2d22 rotary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATM NO.01 DW6306900 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2,oZa\_ I, &k' esiding at Q S vf--ry I k A qg- M-4441 4� kj , f t_(S? do hereby authorize V?�y;n G( -Rr-CLQ 1;A to apply on my behalf to the Town of Southold uilding Department for approval as described herein. �- Owner's Signature Da e Print Owner's Name 2 ILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD -Town Hall Annex - 54375 Main Road - PO Box 1179 OGSoOepc�cL� Southold, New York 11971=J959 ;. 10"N °' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr ccD-southoldtownny.gov - seand(a—)southoldtownny.-gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required). Date: Company Name: . „ Electrician's Name: License No.: m C q 3pet $ Elec. email: r4WIn Elec. Phone No: 5-,(4, ; _ 3�- ❑I request an email copy of Certificate of Compliance Elec. Address.: �; - S 5 -05-spd 1U 117 S JOB SITE INFORMATION (All Information Required) Name: �i*�� Address: ci IQ �' , S'„ IL M , A/ Cross Street: Phone No.: j Q zt — Bldg.Permit#: A? 9 email: Tax Map District: 1000 Section: s Block: 0 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):. Square Footage: Circle All That Apply: Is job ready for inspection?: ® YES ❑ NO. ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect[]Service Reconnect❑Underground❑Overhead #Underground Laterals❑1 ❑2 ❑ H Frame ❑ Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION i t. uT L� POS GATE �o NZ TO m WOOD FENCE o �o `_L„ POLE WOOD FENCE v N z v z m Z r- z r z N z � � x m O f rn O z c N 0 0 m -4 t0 m rmn UTILITY m POLE �. p DOG F,QY�'•. PEN FENCE LINK AJVI �,., UTILITY PARK AVENUE i Fs POLE 0.11IrY POLE— - GUY 1L #23B1 WIRE N GRANITE n MON. STONE > BUILDING N o" La GRATE D RATE NO a 3 RATE c 9L FRAME BUILDING a> �SS O (� 0 1pq:OOF OVER �Ly� WOOD PORCH o ? o� o m 2 �r m ` o ROOF OVER K WOOD PORCH METAL x 3 STORY COVER o STONE. FRAME & STUCCO HOUSE ax� z o AN a ROOF OVER x v 0 OPEN PORCH Z C) r� > > a z o � z o OVER Z PATIO 0 o ro DRNEWAY mz OR m n ix m HEDGE Z N SLATE PATIO lIk f tE =;o55 m INGROUND S� w v m POOL ATE FOUNTAIN .1 00 00 z to p m O SLATE WOOD WOOD -1* N N K DECK BULKHEAD LA AT TE PAVILION PAVILION WOOD SLATE ODD POO�LEHOUSE � WOOD HIGH WATER MARK BULKHEAD WALK DECK WOOD BULKHEAD N GATE WOOD BULKHEAD BULKHEADWO D RAIL FENCE STONE & CONC.SEAWALL W000 & VINYL BULKHEAD OOD 562.56' N SEAWALL Z GATE S 85'37'24" W DECK Lo p o � 0 cog 0 cog c�� o� m 0 0 mo M0 Ao ;Do Mo o V n: o 0 00 00 0 00 00 p0 00 N_. W o o zo zv z zo zo z zo O co z o S 85°35'50" W 542.55' r,, z .S.C. rax No N 1000-123-09-01 . N, YOM Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent or that Carrier 1a. Legal Name and Address of Insured(Use street address only) 1 b.Business Telephone Number of Insured Standard Electric Corp 516-499-7354 Calogero Brutto 6500 Jericho Tpke. 1 c. Federal Employer Identification Number or Social Security Syosset, NY 11791 Number Work Location of Insured(Only required if specifically limited to 208322723 certain locations in New York State,i.e.a Wrap-Up Policy) 2, Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier Standard Securitv (Entity Being Listed as Certificate Holder) 3b. Policy Number of entity listed in box"1a": 62310-00 Town of Southold 54375 Main Road 3c. Policy effective period: Southold, NY 11971 03/26/2010 03/26/2023 4. Policy provides the following benefits: A. All for the employer's employees eligible under the New York Disability Law B. Only the following class or classes of employer's employees: _C. Paid family leave benefits only 5. Policy covers: —A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law _B. Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed 2/1/2022 By: David M Borg (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone No. 631 673 7600 Name and Title: President IMPORTANT: If box 4a is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If box"4b"is checked,this certificate is NOT COMPLETE for the purposes of Section 220, Sub.8 of the Disability Benefits Law. It must be mailed for completion to the Workers'Compensation Board, DB Plans Acceptance Unit, 328 State Street, Schenectady, New York 12305 PART 2.To be completed by the NYS Workers Compensation Board(Only if Box 4C or 5B of Part 1 has been checked State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named-insured employer has complied with the NYS Disability Benefits Law with respect to all or his/her employees. Date Signed By: (Signature of NYS Workers'compensation Board Employee) Telephone No. Title: Please Note: Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS license insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance Brokers are not authorized to issue this form. D13120.1(10-17) NEW c Workers' CERTIFICATE OF C STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE 'lam Board 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Standard Electric Corp 516-499-7354 CalogeroBrutto 6500 ger Br Tpke. 1 c.NYS Unemployment Insurance Employer Registration Number of Syosset, NY 11791 Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 208322723 xx- 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Twin Citv Fire Ins Co Town of Southold 54375 Main Road 3b.Policy Number of Entity Listed in Box"1 a" Southold, NY 11971 12WECAJ5V6F 3c.Policy effective period 12/23/2021 12/23/2022 3d.The Proprietor,Partners or Executive Officers are included.(Only heck box if all partners/officers included)all excluded or certain partners/officers xclut. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever Is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Borg& Borg Inc., David M Borg President (Print name of authorized representative or licensed agent of insurance carrier) A/! � 2/1/2022 Approved by: (Signature) (Date) Title:_Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier: 631-673-7600 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov ACOO® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) 2/1/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Borg&Borg Inc. PHONE FAX 148 East Main Street Arc a 631-673-7600 ac NoZ 631-351-1700 Huntington NY 11743 ADDRESS: INSURERS)AFFORDING COVERAGE NAIC# INSURERA:Merchants Mutual Insurance 23329 INSURED STANELE-01 INSURER B: Standard Electric Corp INSURERC: Calogero Brutto 6500 Jericho Tpke. INSURER D: _ Syosset NY 11791 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:440138992 REVISION NUMBER: 'THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR I TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP w �i LIMITS LTR i POLICYNUMBER MM/DD/YYYY MMIDD YYY A X COMMERCIAL GENERAL LIABILITY BOP1083594 211/2022 2/1/2023 EACH OCCURRENCE $1,000,000 CLAIMS-MADE OCCUR PREMISES(Ea occur°apel— 500,000 MED EXP(Any one person) $15,000_ PERSONAL&ADV INJURY $Included GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICYu JECT �LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ A AUTOMOBILE LIABILITY CAP1075066 2/1/2022 2/1/2023 COMBINED SINGLE LIMIT $1,000,000 Ea accident _ x ANY AUTO BODILY INJURY(Per pomon) $� OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS _ X HIRED X NON-OWNED PROPERTY DAMAGE —_ $ IAUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE is EXCESS LIAR HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ Is WORKERS COMPENSATION AND EMPLOYERS'LIABILFTY YIN SPTER ERH ANYPROPRIETOR/PARTNERIEXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ II es,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT I S DESCRIPTION OF OPERATIONS r LOCATIONS I VEHICLES(ACORD 101,Additional Romarks Sehedulo,may bo attaehod It mora spaco is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road Southold NY 11971 AUTHORIZED REPRESENTATIVE �c,� ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD MCCn APPROVED AS NOTED DATE!! —;tQ B.P._# 4 COMPLY WITH ALL CODES OF a FE 235.00 BY NEW YORK STATE & TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED ' sourHOLOTowNzaa FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, SOUTHOLD TOWN PLANNING BOARD STRAPoING. ELECTRICAL&CAULKING 3. INSULATION SOUTHOLD TOWN TRUSTEES 4. FINAL-CONSTRUCTION &ELECTRICAL MUST BE COMPLETE FOR C.O. N.Y.S.DEC ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. 9LEICAL jN,9PE-Gjrj0N REQUIRED Additional Certification May Be Required, KOHLER. JUN 2 fl 7n79 Model: 60RCI..A BUILDING DEPT Multi-Fuel i0«•INI OF SOUTHLfD LPG/Natural Gas 09001 Standard Features • Kohler Co. provides one-source responsibility for the �NONLOL generating system and accessories. NATIOKAW REGI5TEREe • The generator set and its components are prototype-tested, factory-built,and production-tested. • The generator set accepts rated load in one step. • A standard 5-year/2000-hour limited warranty covers all systems and components. • Quick-ship(QS)models with:tlected features are available. See your Kohler distributor for details. . RDC2 Controller o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT ATS). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to changing demand. o Digital voltage regulation protects your valuable The Kohler® Advantage electronics from harmonic distortion and unstable power quality. • Nigh Quality Power • Engine Features Kohler generators provide advanced voltage and o Powerful and reliable Kohler 6.2L liquid-cooled engine frequency regulation along with ultra-low levels of harmonic distortion for excellent generator power quality to o Electronic.engine management system. protect your valuable electronics. o Simple field conversion between natural gas and LP vapor • Extraordinary Reliability fuels while maintaining emission certification. Kohler is known for extraordinary reliability and • Innovative Cooling System performance and backs that up with a 5-year/2000-hour o Electronically controlled fan speeds minimize generator limited warranty. set sound signature. • Aluminum Sound Enclosure • Approved for stationary standby applications in locations Aluminum sound enclosure is standard. served by a reliable utility source. Optional 291 kph(181 mph)wind-load-rated enclosure • Certifications door kit is available for field installation. o The 60 Hz generator set engine is certified by the • Fast Response Environmental Protection Agency(EPA)to conform to the Kohler's Fast-Response®X excitation system delivers New Source Performance Standard(NSPS)for stationary excellent voltage response and short-circuit capability spark-ignited emissions. using a rare-earth permanent magnet(PM)-excited o UL 2200/cUL listing is availbble(60 Hz only). alternator. o CSA certification is available(60 Hz only). • Quiet Operation o Accepted b the Massachusetts Board of Registration of Kohler home generators provide quiet,neighborhood- Plumbers and Gas Fitters. friendly performance. Generator Set Ratings Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 120/208 3 60 60/75 209 60[75 209 127/220 3 60 60/75 197 60/75 197 120/240 3 60 60/75 181 60/75 181 4P10X 277/480 3 60 60/75 91 60/75 91 220/380* 3 50 50/62 95 50/62 95 230/400 3 50 50/62 90 50/62 90 240/416* 3 50 50/62 87 50/62 28577' — �.--- rye✓ i.;!E�tPXAft.2401_;,_ .8F0 * 5o Hz models are factory-connected as 23o/400 volts. Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. RATINIaS AB a.6e#18se ores me races at 0.9 p mer tecier shtgie ptsase udts are rimed g 1.0 fa�c y aMly to irsteNEdiors served by 8 t rd ty wase The statdby ratln9 b aPWicable to varying loads for the duadat of a power adage.There Is rq aveAo�i cepebl6ty for Cds ra�drg.Re6ngs ere in aocardence wdh IS08528.1 erid IS0�0461.Obmin tedrd� Udonrlabort buletln TIB-tot far tetlngs gudefirres,��ratlngs de6rilfons,end sae car�tlon dentes. The generator set rtranuFeobaer reserves the rfglx to cfiarge the design or spea6cariars v�had ratios ane v6tlTout any obNgetlort a qty vrhetsoever.Availabi6ry is> � w6dlord nadce+. Cordae you loml KotdeT generator dslnt>tdor 11x . oa-zn (soRct� 71t8b Alternator Specifications Specifications Akemator • The unique Fast-Response®X excitation system delivers Manufacturer Kohler excellent voltage response and short-circuit capability using a Type 4-Pole,Rotating Field rare-earth,permanent magnet(PM)-excited alternator. Exciter type Brushless,Rare-Earth • Brushless, rotating-field alternator. Permanent Magnet ® NEMA MG1, IEEE,and ANSI standards compliance for Leads:quantity,type temperature rise and motor startin�. 4P10X 12,Reconnechable 4Q10X 4,110-120/220-240 • Sustained short-Circuit current of up to 300%of the rated Voltage regulator Solid State,Votts/HZ current for up to 10 seconds. Insulation: NEMA MG1 • Sustained short-circuit current enabling downstream circuit Material Class H Temperature rise 130°C,Standby breakers to trip without collapsing the alternator field. Bearing:quanPty,type 1,Sealed • Self-ventilated and dripproof construction. Coupling Flexible Disc Amortisseur windings Full • Windings are vacuum-impregnated with epoxy vamish for Voltage regulation,no-load to full-load ±1.0%RMS dependability and long life. Unbalanced load capability 100%of Rated Standby • Superior voltage waveform from a two-thirds pitch stator and Current skewed rotor. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion(THD)from no load to full load with 480 V,400 V 4P1 OX(12 lead) 275(60 Hz),220(50 Hz) a linear load is less than 3.5%. 240 V,220 V 401 OX(4 lead) 144(60 Hz),132(50 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type KG6208 6.2L Exhaust flow at rated kW,m3/min.(cfm) 16.4(580) 13.6(480) Natural Aspiration Exhaust temperature at rated kW,dry Cylinder arrangement V-8 exhaust,°C(°F) 849(1200) Rated rpm 1800 1500 Maximum allowable back pressure, Displacement,L(cu.in.) 6.2(378) kPa(in.Hg) .i 10.2(3.0) Bore and stroke,mm(in.) 101.6 x 95.25(4.00 x 3.75) Exhaust outlet size at engine hookup, Compression ratio 10.5:1 mm(in.) , 76(3.0)OD Max.power at rated rpm,kW(HP) 77.0(103) 64.3(86) Cylinder head material Cast Aluminum Fuel Piston type and material High Silicon Aluminum Fuel System Crankshaft material Cast Iron Valve(exhaust)material Forged Steel Fuel type LP Gas or Natural Gas Governor type Electronic Fuel supply line inlet 1 in.NPT Frequency regulation,no-load to full-load Isochronous Natural gas fuel supply pressure, Frequency regulation,steady state s1.0% kPa(in.HO) 1.74-2.74(7-11) Frequency -Fixed LPG vaporrwithdrawal fuel supply Air cleaner type Dry Pressure,kPa(in.H2O) 1.24-2.74(5-11) Fuel Composition Limits* Nat Gas LP Gas Engine Electrical Methane,%by volume 92 min. - Engine Electrical System Ethane,%by volume 4.5 max. - Ignition system Electronic Propane,%by volume 1.0 max. 87 min. Battery alternator: Propene,%by volume 0.1 max. 5.0 max. ry ch�n9 C4 and higher,%by volume 0.3 max. 2.5 max. Ground(negative/positive) Negative Sulfur,ppm mass 25 max. Volts(DC) 12 Lower heating value, Ampere rating 130 MJ/m3(Bk#",min. 33.2(890) 84.2(2260) Starter motor rated voltage(DC) 12 A Fuels with other compositions may be acceptable. If your fuel is Battery,recommended cold cranking outside the listed specifications,contact your local distributor for amps(CCA): further analysis and advice. Qty.,rating for-18°C(0°F) One,630 Battery voltage(DC) 12 Lubrication Battery group size 24 Lubricating System Type Full Pressure Oil pan capacity,L(qt.) 5.7(6.0) Oil pan capacity with finer,L(qt.) 7.1 (7.5) Oil finer:quantity,type 1,Cartridge r 64.277 (soaCLa,) 7n8b Application Data s Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature,°C(°F) 45(113) Radiator system capacity,including engine,L(gal.) 21.3(5.6) vareea: zaov Engine jacket water flow,Lpm(gpm) 131 (34.6) 109(28.8) 0 Heat rejected to cooling water at rated t ®®® kW,dry exhaust,kW(Btu/min.) 54(3070) 49(2790) Water pump type Centrifugal Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by engine battery charging alternator) 12VDC,18 amps each The RDC2 controller provides integrated control for the Operation Requirements generator set, Kohler®Model RXT transfer switch, Air Requirements 60 Hz 50 Hz programmable interface module(PIM),and load shed kit. Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status m3/min.(scfm)t 62.2(2200) 62.2(2200) messages and y stem settings that are clear and easy to read, Air over engine,m3/min.(cfm) 31.1 (1100) 31.1 (1100) g y even in direct sunlight or low light. Combustion air,m3/min.(cfm) 5.5(195) 4.6(162) t Air density=1.20 kgW(0.075 Ibm/lt3) RD02 Controller Features Fuel Consumption* • Membrane keypad: Natural.Gas,m3/hr.(c h)at%toad 60 Hz 50 Hz o OFF,AUTO,and RUN pushbuttons 100% 28.7(1013) 24.9 (878) o Select and arrow buttons for access to system 75% 21.6 (761) 18.7 (660) configuration and adjustmrint menus 50% 14.0 (493) 12.1 (427) • LED indicators for OFF,AUTq,and RUN modes 25% 7.0 (248) 6.1 (215) LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for utility power and generator set source availability and ATS position(Model RXT transfer switch 100% 10.1 (357) 8.8 (309) required) 75% 7.2 (255) 6.3 (221) • LCD screen: 50% 5.4 (191) 4.7 (166) 25% 3.2 (113) 2.8 (98) o Two lines x 16 characters per line # Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btuffi) o Backlit display with adjustable contrast for excellent LP Vapor,93 W/m3(2500 Btu/fl3) visibility in all lighting conditions LP vapor conversion factors: • Scrolling system status display 858 ft.3=1 Ib o Generator set status 0.535 m3=1 kg, o Voltage and frequency 36.39 ft.3=1 gal. o Engine temperature o Oil pressure Sound Enclosure Features o Battery voltage e Sound-attenuating enclosure uses acoustic insulation that o Engine runtime hours meets UL 94 HF1 flammability classification and repels • Date and time displays moisture absorption. • Smart engine cooldown senses engine temperature • Internally mounted critical silencer. • Digital isochronous governor to maintain steady-state speed • Skid-mounted,aluminum construction with two removable at all loads access panels. • Digital voltage regulation: ±1.0%RMS no-load to full-load • Scratch-and corrosion-resistant Kohler®cashmere • Automatic start with programmed cranking cycle powder-baked finish. • Programmable exerciser can-be set to start automatically on any future day and time,and run every week or every two, Sound Data weeks Model 60RCLA sound levels are 57 dB(A)during weekly engine • Exercise modes exercise and 61 dB(A)during normal operation. o Unloaded exercise with complete system diagnostics All sound levels are measured at a distance of 23 ft. (7 m)from o Unloaded full-speed exercise the generator set. Actual sound levels may vary based on o loaded full-speed exercise(Model RXT ATS required) installation parameters. • Front-access mini USB connector for SiteTech TM connection • Integral Ethernet connector for Kohler®OnCue@ Plus • Built-in 2.5 amp battery charger • Remote two-wire startMop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. c CA-277 (60RCu+) 7/18b r KOHLER CO.,Kohler,Wisconsin.53044 USA Phone KOHLER, For the nearest sales�and service outlFax et n the US and Canada,phone 14800544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options(continued) • Diagnostic messages Enclosure Option o Displays diagnostic messages for the engine,generator, ❑ 291 kph(181 mph)wind load rated enclosure Model RXT transfer switch,programmable interface Starting Aids§ module(PIM),and load shed kit ❑ Block Heater,120 V o Over 70 diagnostic messages can be displayed ❑ Block Heater,240 V • Maintenance reminders § Recommended for ambient temperatures below 0°C(32°F) • System settings Controller Accessories b System voltage,frequency,and phase ❑ Lockable Emergency Stop(lockout/tagout) o Voltage adjustment ❑ Programmable Interface Module(PI11) o Measurement system, English or metric (provides 2 digital inputs and 6 relajr tputs) • ATS status(Model RXT ATS required) Automatic Transfer Switches and Accessories o Source availability ❑ Model RXT Automatic Transfer Switch o ATS position(normal/utility or emergency/generator) ❑ Model RXT Automatic Transfer Switch with combined interface/ load management board o Source voltage and frequency L) Model • ATS control(Model FDCT ATS required) Automatic Transfer Switch C] Load shed kit for RDT or RXT . o Source voltage and frequency settings ❑ Power relay modules(use up to 4 relay modules for o Engine start time delay each load management device) o Transfer time delays ❑ Other Kohler®ATS o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable Interface Module(PIM)status displays literature o Input status(active/inactive) ❑ General Maintenance Literature Kit o Output status(active/inactive) ❑ Overhaul Literature Kit • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Optional Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features • Aluminum sound enclosure with enclosed silencer Dimensions and Weights • Battery.rack and cables Overall Size,L x W x H,mm(in.): 2280 x 836 x 1182 • Electronic,isochronous governor (89.8 x 32.9 x 46.5) • Engine-generator set is designed and manufactured in Shipping Weight,wet,kg(Ib.): 1 859(1894) facilities certified to ISO:9001. Weight includes generator set with engine fluids and 4Q1 OX alternator, • Flexible fuel line sound enclosure,and silencer. r • Gas fuel system(includes fuel mixer,electronic secondary gas regulator,two gas solenoid valves,and flexible fuel line between the engine and the skid-mounted fuel system components) H • Integral vibration isolation • Line circuit breaker • Oil drain extension • OnCuem Plus Generator Management System for remote monitoring(see specification sheet G6-140) • Operation and installation literature used This drawing is provided for reference only and should not be . used for planning installation. Contact your local distributor for more • RDC2 controller with built-in battery charger "' detailed information. • Standard 5-year/2000-hour limited warranty DISTRIBUTED BY: Available Options Approvals and listings ❑ UL 2200 Listing(60 Hz only) ❑ CSA Approval(60 Hz only) Electrical System ❑ Battery ❑ Battery Heater �c. ®2018 by Kohler Co.All rights reserved. 64-277 (60RCIA) 7/18b .46 a KOHLER. Model: RXT Autd. atic Transfer Switch 100-400 Amps 09001 Model RXT Automatic Transfer Switch srEn s The Model RXT automatic transfer switch is designed for use NATIONALLY REGISTERED only with Kohler®generator sets equipped with RDC2 or DC2 generator set/transfer switch controls. The transfer switch operation is controlled by the RDC2/DC2 controller. Standard Features e Allows utility voltage display on the RDC2/DC2 generator set/iransfer switch controller,available exclusively on Kohler® residential and light commercial generator sets e UL listed o Models with load centers,UL 67 listed,file#E251086 o Models without load centers,UL 1008 listed,file#E58962 e CSA certification,file#LR58301, is available for. o Standard ATS without load center(single and three-phase) o Service entrance ATS 100 and 200 amp models e Corrosion-resistant NEMA 3R aluminum enclosure o Padlockabte o Approved for indoor or outdoor installation o ANSI 49 gray e NEMA 1 enclosure available on,100 amp load center models e Contactor electrically and mechanically interlocked e Double throw inherently interlocked design e Contactor manually operable for maintenance purposes e Silver alloy main contacts e Transfer switches are 100%equipment rated and can be applied at the rated current without derating(non-service entrance models) e Service entrance models include disconnect circuit breaker on the utility(normal)source side(80%rated) e Five-year limited warranty Covers have been removed for illustration. Standard Interface Board e Standard interface board connects to the Model RDC2 or D02 generator set/transfer switch controller. Available Models a Includes a load control contact that provides a 5 minute time e 100,200,and 400 amp standard and service delay for startup of selected loads after transfer to the entrance models are available. emergency source. Use for large motor loads. e 150 and 300 amp service entrance models are also Combined Interface/Load available. Management Board e Combined interface/load management board is available on single-phase standard and service a Optional combined interface/load management board entrance models. (Not available on 3-phase or load replaces the standard interface0oard and connects to the center models.) Model RDC2 or DC2 generator set/transfer switch controller. e 100 amp standard single-phase models are available a The combined board is availablh on single-phase standard with or without a 16-space load center. Up to 8 and service entrance models. tandem breakers can be used for a total of 24 (Not available on 3-phase or load center models.) circuits. • The combined board automatically manages up to six e 100amp standard single phase model with a residential loads:. 12-space load center and a NEMA 1 enclosure is o Up to four customer-supplied power relay modules can available as a standalone non-configurable spec be connected for management of non-essential (GM85273-SA,. secondary loads. e See page 7 for more information. o Two HVAC relays are included for control of two independent air conditioner loads. Gll-140(Model RXf Automatic Transfer Switch) 3118e Pagel Specifications Codes and Standards Standard Interface Board The ATS meets or exceeds the requirements of the following Controller interface connections #20 AWG shielded Wsted-pair specifications: A and B Belden 9402 or 8762 or equivalent a Underwriters Laboratories UL 67,Enclosed Panel Boards Controller interface connections #12-20 AWG (load center models)file#E251086 PWR and COM (see ATS Installation Manual) a Underwriters Laboratories UL 1008,Standard for Automatic Load control contact rating 10 A @ 250 VAC Transfer Switches for Use in Emergency Systems,file Load control connections 1 #12-18 AWG #E58962 Note: For combined interface/load management board a Underwriters Laboratories UL 508,Standard for Industrial specifications, see page 3. Control Equipment e CSA certification available,file#LR58301 (not available for Environmental Specifications 150,300,or 400 amp service entrance or 100 amp load center models). Must be selected when the transfer switch Operating temperature -2o°C to 70°C(-4°F to 158°F) is ordered. Storage temperature -40°C to 85°C(-40°Fto 185°F) a NFPA 70,National Electrical Code Humidity. 5 to 95%noncondensing a NFPA 110,Emergency and Standby Power Systems e NEMA Standard ICI 0-1993,AC Automatic Transfer Switches •i Cable Sizes , AL/CU UL-Listed Solderless Screw-7ype Terminals for External Power Connections switch 'Range of Wire Sizes,Cu/AI Size, Amps Switch phases Normal and Emergency Load Neutral Ground Standard 1 (1)#14-1/0 AWG (1)#14-1/0 AWG (5)#12 to 250 KCMIL(Cu)or (5)#10 to 250 KCMIL(AI) 12-space per customer-supplied (13)#4-14 AWG or load center 1 (1)#14-1/0 AWG circuit breaker (1)#6-2/0 AWG (9)#6-#14 AWG (NEMA 1) (4)#14-1/0 AWG 100 16-space per customer-supplied (27)#4-14 AWG or bad center 1 (1)#14-1/0 AWG circuit breaker (3)#4-1/0 AWG or (NEMA 311) 1 (1)#6-2/0 AWG Service 1 Norrnal:(1)#12-2/0 AWG (1)#14-1/0 AWG (5)#12 to 250 KCMIL(Cu)or Entrance Emerg:(1)#14-1/0 AWG (5)#10 to 250 KCMIL(Al) 3-Phase 3 (1)#14-1/0 AWG (1)#14-1/0 AWG (3)#4 AWG-600 KCMIL (4)#14-1/0 AWG (6)1/0 AWG-250 KCMIL (9)#14-#6 AWG 150 Service 1 Normal:(1)#4-300 KCMIL (1)#6-250 KCMIL (5)#12 to 250 KCMIL(Cu)or 200 Entrance Emerg:(1)#6-250 KCMIL (5)#10 to 250 KCMIL(M 200 Standard 1 (1)#6 AWG-250 KCMIL (1)#6-250 KCMIL (5)#12 to 250 KCMIL(Cu)or (9)#14-#4 AWG 3-Phase 3 (5)#10 to 250 KCMIL(AI) (4)#14-1/0 AWG Normal::(1)#1-600 KCMIL 300 service 1 or(2)#1-250 KCMIL (2)#6-250 KCMIL (3)114 AWG-600 KCMIL (6)#6-3/0 AWG 400 Entrance Emerg:(2)#6-250 KCMIL (6)1/0 AWG-250.1(CMIL (2)#6-250 KCMIL (2)#6-250 KCMIL �� (3)#4 AWG-600 KCMIL 1 208-240 V 3 (6)#6-3/0 AWG (6)1/0 AWG-250 KCMIL 3 or 4 pole 3 (1)#4-600 KCMIL (1)#4-800 KCMIL 480 V (2)1/0-250 KCMIL (2)1/0-250 KCMIL Note: Data is subject to change.Refer to the transfer switch dimension drawings and wiring diagrams for planning and installation. G11-140(Model RXT Automatic Transfer Swih;h) 3/18a Page 2 F ' Optional Combined Interface/Load Management Board The RXT transfer switch is available with either a standard Priority Setting interface board or a combined interface/load management • Loads are added and shed according to their priority. Load 1 board. The combined board allows load management as is the top priority,which is added first and shed last. Load 6 described below. is the lowest priority. • Less critical loads can be turned off automatically when Load Management essential appliances are running. • The combined load management board disconnects • Load priorities are hard-wired at installation. non-critical loads to prevent generator overload,in compliance with NEC. Viewing Load Shed Outputs with OnCue@ • The combined load management board monitors generator Pius current and frequency to determine when to add or shed • Use Kohler's OnCue@ Plus Gbnerator Management System loads. This monitoring prevents frequency drops that can damage valuable electronics like computers and televisions. (sold separately)to view load status(On or Oft)for loads • Load management allows the use of a smaller generator set. connected to the load shed relays. • Use OnCue®Plus to remotely monitor when loads are shed Operation or added. • Loads are automatically added or shed based on generator • The load shed outputs can be labeled in OnCue@ Plus. capacity. Current Transformer • The load control system uses dynamic logic to prevent shedding important loads unnecessarily when air • The combined load management board option includes a conditioning,refrigerator,or water pump motors start 400 amp current transfomer(CT)for load monitoring. (patent pending). • A larger diameter CT is available for applications that require • The load management board and generator communicate to larger cables• provide smart power management. The time to shed loads • A 500 amp CT is available for use with a 60RCL generator. decreases as each load is shed to quickly adapt to critical • See the table below for current transformer specifications power requirements. and optional kit numbers. • Load shed power level and frequency setpoints can be adjusted using a personal computer paptop)and Kohler@ SiteTech- software,which is only available to Kohler- authorized distributors and dealers. Load Shed Specifications Connection Rating Connection Pilot Relays* 125VAC, 10 A total(general purpose) #12-20 AWG 120VAC, 125VA(pilot duty) HVAC Relays(qty.2) 125VAC,10 A(general purpose) #12-20 AWG 120VAC, 125VA(pilot duty) RBUS Communication and Power Use Belden#9402 or equivalent 20 AWG Connections to the RDC2/DC2 0.5 A @ 12 VDC shielded,twisted-pair communications controller cable t * Four(4)pilot relays are provided for customer-supplied normally closed load-switching contactors/relays. The combination of four load relay outputs cannot exceed 10 amps total current draw. Kohler@ power relay modules are recommended. # For long distances,use an equivalent shielded,twisted-pair cable for RBUS connections and individual 12-20 AWG wires(qty.2)for power connections. Current Transformer Specifications Ratio Outer Diameter Inner Diameter Service Part (Amps:VAC) mm pn.) mm(in.) Number Sales Kft Part Plumber CT Availability 400:3 63.5(2.5) 28.7(1.13) - GM83929 N/A Included with combined board 400:3 111.8(4.4) 57.2(2.25) GM17250 GM17250-KPI-QS Sold Separately 500:3 ' 171.5(6.75) 108.0(4.25) GM60264 GM17250-KP2-QS Sold Separately (use With 60RCL) .t r � i G71-140(Model RXT Automadc Transfer Snitch) 3/189 Page 3 Withstand and Close-On Ratings (WCR) Service Entrance Transfer Switch Ratings The service.entrance transfer switch is factory-equipped with a normal source disconnect circuit breaker., Suitable for the control of motors,electric discharge lamps,tungsten filament lamps and electric heating equipment where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent of switch rating. Switch Rating,Amps* WCR,RMS Symmetrical Amps at 240 VAC 100,150,200 22,000 300,400 35,000 * Continuous load current not to exceed 80%of switch rating. Contactor Ratings with Coordinated Circuit Breakers Single-phase transfer switches are UL listed at 240 VAC maximum. Three-phase transfer switches are rated at 480 VAC maximum. The following table lists contactor withstand current ratings(WCR)for 100-400 ampere non-service entrance rated switches with specific manufacturer's circuit breakers per UL and Canadian safety standards. Suitable for the control of motors, electric discharge lamps,tungsten filament lamps and electric heating equipment where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent of switch rating. The transfer switch is rated for use on a circuit capable of delivering not more than the RMS symmetrical amperes maximum as shown in the tables below,but no greater than the interrupting capacity of the selected breaker. WCR Ratings with Specific Manufacturer's Molded-Case Circuit Breaker Switch Number WCR,RMS Rating, Voltage, of Poles/ Symmetrical ' Maximum Amps max. Phases Amps Manufacturer Type or Gass Size,Amps 100 240 1 pole 10,000 Any Breaker* Any Breaker(0.025 seconds max.) — 11500 240 1 p 10,000 Any Breaker* Any Breaker(0.025 seconds max.) — hase FCL 100 JGS,JGH,JGC,JGU,JGX,JBD,JD,HJD,JDC, 250 Eaton LCL,LCLA LDC,CLDC,KDB,KD,HKD,KDC,LD,CLD, 400 HLD,CHLD CEDE,HED4,HED6 125 CFD6,FD6A,FXD6,HFD6,HFXD6,HHFD6, 250 3 pole/ ITE/Siemens 3 HHFXD6 100 CJD6 400 200 480 4 �/ 30,000SEL,SEP,THLC1,PE E,PE N,PE H,PE L 150 3 phase THLC2 225 General Electric SFH,SFL,SFP,PE E,PE_N,PE H,PE.L 250 SGH,'SGL,SGP,FGN,FGH,FGL,FGP,PG_E, 400 PG_N,PG_H,PG_L,PG P HG,HJ,HL,HR 150 Schneider JJ,JL,JR 250 LG,U,LL,LR 400 * For higher WCR values,contact the factory for additional specific breaker ratings. 6 G11-140(Model RXT Autanalic Transfer Switch) Wl Be Page 4 a WCR Ratings with Specific Manufacturer's Molded-Casa Circuit Breakers Switch Number WCR,RMS Rating, Voltage, of Poles/ Symmetrical Maximum Amps max. Phases Amps Manufacturer Type or Class Size,Amps ABS T5,T6 600 CHKD,CKD,DK,HKD,KD,KDB,KDC, 400 LATRIPAC,LCL Eaton CHLD,CLD,CLDC,HLD,LD,LDB,LDC 600 HMDL,MDL,NB TRI-PAC 800 General Electric FGH,FGL,FGN,FGP,SGHA 600 CJD6,HHJD6,HHJXD6,HJD6,HJGA,HJXD6, JD6,JXD2,JXD6,SCJD6,SHJD6,SJD6,NJGA, 400 6 WGA 35,000 300ash CLD,HHLD,HHLXD,HLD,HLGA,HLXD,LD600 , Siemens LLGA,LXD,NLGA,SCLD,SHLD,SLD CMD,HLMD,HLMXD,HMD,HMG,HMXD,LMD, LMG,LMXD,MD,MXD,NMG,SCMD,SHMD, 800 SMD' LA,LC,LE,LH,U,LX,LXI 400 Square D DG DJ DL,LC,LE,LI,LX,LXI 600 CAOOH,CJ400L,GJ40ON 400 Merlin Gerin CJ600H,CJ600N 600 3 pole/ 35,060 Any Breaker Any Breaker(0.017 seconds ma),� 600 3 Phi 50,000 Eaton LD , 600 HJD,JDC,JGC,JGH,JGU,JGX 250 CHLD4,CLD,HLD4,CLDC,LDC,KDC,HKD, 400 CHMDL4,CMDL4 Eaton CHLD6,HDLG,CHMDL6,CMDL6,CLDC,CLD6, 600 LDC6,CLDC6 CHMDL8,HMDL8,MDL:8,CMDL8 800 CFD6,HFD6,HFXD6,HHFD6,HHFXDB 250 CJD6 400 3 pole/ ITE/Siemens 3 phase CLD6,HHLD6,HHLXD6,HLD6,HLXD6 600 400 486 50,000 CMD6,MD6,HMD6,HMXD6,MXD6 800 4 pole/ SEL,SEP,PE N,PE H,PE L 150 3 phase SFL,SFP,PE N,PE H,PE_L 250 General Electric SGL,SGP 400 FGL,FGP,SGL,SGP,PG-H,PG_L,PG N, 600 PG-P HJ,HL,HR 150 JJ,JL,JR 250 Schneider W,LL,LR 600 MJ 800 A i G11-140(Model RXT Automatic Transfer Switch) 3/188 Page 5 Dimensions and Weights Note: /Always use the transfer switch dimension drawing for planning and Installation. Weights and dimensions may vary for different configurations. See the Operation/Installation Manual or your local distributor for dimension drawings. Transfer switch weights and dimensions shown in the table do not include packaging. To estimate the shipping weight,add 3 kg (5 lbs.)or-10%(whichever is larger)to the weight shown. H W i i- ®*-i Shipping Weight * Dimension Amps Description Dimensions H x W x D mm n. f kg Ob.) Drawing Single phase 623 x 335 x 180 (24.5 x 13.2 x 7.1) t 7 (15) ADV-8688 With 12-or 16-space load center(NEMA 1) 610 x 330 x 154 (24.0 x 13.0 x 6.0) 12 (26) ADV-8487 With 16-space load center 614 x 335 x 180 (24.2 x 13.2 x 7.1) 8 (18) ADV-8690 100 Three phase 682 x 462 x 228 (26.8 x 18.2 x 9.0) 14 (30) ADV-8889 Service entrance(ASE) 734 x 416 x 175 (28.9 x 16.4 x 6.9) 10 (22) ADV-9046 Service entrance(CSE) 754 x 416 x 175 (29.7 x 16.4 x 6.9) 14 (30) ADV-8797 150 Service entrance(ASE) 734 x 416 x 175 (28.9 x 16.4 x 6.9) 12 (26) ADV-9046 Service entrance(ASE) 734 x 416 x 175 (28.9 x 16.4 x 6.9) 12 (26) ADV-9046 Service entrance(CSE) 754 x 416 x 175 (29.7 x 16.4 x 6.9 16 (36) ADV-8798 200 Single phase 623 x 335 x 180 (24.5 x 13.2 x 7.1) 7 (15) ADV-8688 Three phase 682 x 462 x 228 (26.8 x 18.2 x 9.0) 14 (30) ADV-8689 300 Service entrance 1075.x,559 x 329 (42.3 x 22.0 x 12.9) _ 46 (101) ADV-8694 3-Pole/208-240'volts 1067 x 559 x 329 (42.0 x 22.0 x 12.9) 41 (90) ADV-8692 3-Pole/480 volts 1222 x 610 x 343 (48.1 x 24.0 x 13.5) 59 (130) ADV-8693 '-� 4-Pole 1222 x 610 x 343 (48.1 x 24.0 x 13.5) 59 (130) ADV-8693 Service entrance 1075 x 559 x 329 (423 x 22.0 x 12.9) 46 (101) ADV-8694 t Depth does not include the padlock hasp on the front of the enclosure. * Transfer switch weights are approximate and do not include packaging. Note: Enclosures are type NEMA 3R except as noted. l G11-140 (Model R)CT Autom Transfer SwiMh) 3M 8e Page 6 A Accessories ❑ Auxiliary position-Indicating contacts ❑ Status Indicator kit for combined Interface/load • One closed on normal position and one closed on emergency management board position • LEDs indicate normal and emergency source availability • Form C contacts rated 15 A @ 250 VAC and contactor position ❑ Power relay modules • Dual color LEDs for each load indicate load status • 50 amp DPST power relay mounted in a NEMA type 3R (powered or shed)and flash during a test enclosure • Load shed test button allows the operator to cycle the • Use up to four modules with the combined interface/load load mode) in order of priority(when generator is in RUN management board ) • Mounts on the outside of the RXT enclosure • UUcUL listed • View transfer switch and load status without removing • Dimensions: 172 x 233 x 92 mm(6.8 x 9.2 x 3.6 in.) enclosure cover • For more information,see specification sheet G6-143 • An overhang on the enclosure protects the indicator ❑ Status Indicator kit for standard interface board . panel and ribbon cable opening • LEDs indicate normal and emergency source availability • Dimensions: 183 mm x 42 mm(7.20 in.x 1.65 in.) and contactor position o Connects to the combined interface/load management • Mounts on the outside of the RXT enclosure board only • View transfer switch status without removing enclosure • For more information on the status indicator kit,see cover specification sheet G11-123 • An overhang on the enclosure protects the indicator ❑ Auxiliary circuit breaker(;'arvice entrance models only) panel and ribbon cable opening • 15 amp single-pole type 00 circuit breaker • Dimensions: 92 mm x 42 mm(3.62 in.x 1.65 in.) • Mounts on a bracket inside the enclosure • Connects to the standard interface board only • For more information on the status indicator kit,see specification sheet G11-123 Available Models All Model RXT transfer switches are standard-transition 60 Hz automatic transfer switches. Letters in parentheses refer to the model designation code described on the last page. Description Voltages WCR§ Am Connections 208(C) 240(F) 480(M) Poles Phases RMS symmetrical Amps Standard(A) • 2(N) 1 10,000 Standard,with 16-space load • 2(N) 1 10,000 center(B)I 100 Standard,with 12-space • 2(N) 1 10,000 load center** Service entrance(ASE,CSE) • 2(N) 1 22,000 Standard,3-phase(A) • • • 3(1)or 4(V) 3 30,000 150 Service entrance(ASE) • 2(N) 1 22,000 Standard(A) • 2(N) 14 10,000 200 Service entrance(ASE,CSE) • 2(N) 1 22,000 Standard,3-ph a(A) • • • 3(T)or 4(V) 3 30,000 300 Service entrance(ASE) • 2(N) 1 35,000 Standard(A) • 2(N) 1 54,000 Service entrance(ASE) • 2(N) 1 35,000 Standard,3-phase(A) • . • 3(T)or 4(1/) 3 50,000 § Withstand and close-on rating. See pages 3-5 for WCR information and specific breaker ratings. ¶ With 16-space load center and NEMA 1 or NEMA 3R enclosure. Up to 8 tandem breakers can be used,for a maximum of 24 circuits. *"GM85273-SA_with 12-space load center and NEMA 1 enclosure. Note: Combined interface board is available on single-phase standard or service entrance models. (Not available on 3-phase or load center models.) �t G11-140(Model RXT AutomaticTransfer Swkch) 3/18e Pap? r KOHLER CO.,Kohler,Wisconsin 53044 USA KOHLEk Phone92G-457-4441,salesFax service 9-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-5442444 KOHLERPower.com Model Designation Model Controls Voltage Poles Enclosure Current Rating t Connections Record the transfer switch model designation in the boxes. The transfer switch model designation defines ratings and characteristics as explained.below. Semple Model Designation: RXT-JFNC-0200A Model Enclosure RXT: Kohler Automatic Transfer Switch A:—NEMA 1 Controls �C: NEMA 3R J: Interface for RDC2/DC2 Controller NEMA 1 enclosure is available on 100 amp load center models only. (standard or combined interface/load Current Rating management) 0100: 100 amps 0300-300-amps Vottage/Frequency 0150:.150 amps0400 400 amps C: 208 Volts/60 Hz(3-phase only) 0200:200 amps F: 240 Volts/60 Hz Connections M: 480 Volts/60 Hz(3-phase only) A: No load center Number of Poles/Wires B: With load center(100 amp single-phase only) N: 2-pole,3-wire,solid neutral(120/240 V only) ASE: Service entrance rated . T: 3-pole,4-wire,solid neutral CSE: Service entrance rated with CSA.oprtification V. 4-pole,4-wire,switched neutral (100/200 amps only) DISTRIBUTED BY: .t Availability is subject to change without notice.Kohler Co.reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler® z' generator distributor for availability. ®2014,2015,2018,2018 by Kohler co. All rights reserved. G11-140 (Model R)CT Automatic Transw switch) 3/18e Pag9 8