Loading...
HomeMy WebLinkAbout47976-Z o���FFOI Town of Southold 1/25/2023 y� P.O.Box 1179 o - o _ 53095 Main Rd yy,01 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43784 Date: 1/25/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 25500 Route 25,Orient SCTM#: 473889 Sec/Block/Lot: 18.-6-10 Subdivision: Filed Map No. Lot.No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/20/2022 pursuant to which Building Permit No. 47976 dated 6/21/2022 wag issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Sutton,Alexander&Tracy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47976 12/30/2022 PLUMBERS CERTIFICATION DATED A o ize S griature VSUEFoio` TOWN OF SOUTHOLD ��� BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • oma " SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47976 Date: 6/21/2022 Permission is hereby granted to: Sutton, Alexander 25500 Route 25 Orient, NY 11957 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 25500 Route 25, Orient SCTM # 473889 Sec/Block/Lot# 18.-6-10 Pursuant to application dated 5/20/2022 and approved by the Building Inspector. To expire on 12/21/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector *OF SO�r�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G sean.devlina-town.southold.ny.us Southold,NY 11971-0959 '`Qly '� coum BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alexander Sutton Address: 25500 Route 25 city:Orient st: NY zip: 11957 Building Permit#: 47976 Section: 18 Block: 6 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: SUNation Energy License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Surrey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 16.8kW Roof Mounted PV Solar Energy System w/ (46) REC 365AA Modules, 80A Disconnect, Combiner Panel Notes: Solar Inspector Signature: Date: December 30, 2022 S. Devlin-Cert Electrical Compliance Form OE SOUly�lo L�10\7 10 ?_YS 0 0 M k I r1 r-,`j # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: IN 04 o f nl SI t, Oe 12 SZ oNM5I 1 DATE 17 /IS, AN SPECTOR -- # * TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL %twv [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 0 DATE '1/ INSPECTOR Graham Associates 256-A Orinoco Drive,Brightwaters,NY 11718 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 July 9, 2022 FTown of Southold Post Installation Certification .IAP 2 Re: Permit # BUILONG DEPT. TnIg1A1 Sutton Residence 25500 Main Road, Orient Inspection Date: 6/30/2022 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Graham Associates to be in compliance with the minimum requirements of the 2020 New York State Residential Building Code; Town Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-10. If you have any further questions, do not hesitate to call. �N-0 N air .L lchael K Dunn, RA r l - _ � T1Nlitl]MY 9NWyYM� Will moot wDVF11R MCiA _ ��.�- •S _J T +. f r _ •.+.mss�:.::.�'�".,.�'..",+ _ ON GENERA. UTILFTY [ SERVICE DISCONNECiOF� , Kir 4 I r ,. Is ao l PNOTOVOLVAIC AC W YM�[Q4rtI,lpR m. OftiuTNfTAGVQiviE 1 •.44 w - IK_ a t � t 1� 7 • 3 Mae Thank • Cecelia Polvere Closeout •• • . • 171 Remington • Ronkonkoma, a • 631-750-9454 Fax: 6'31-750-9455 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) -� ------------------------------------ G � FOUNDATION (2ND) A z 0 . H ROUGH FRAMING& PLUMBING N � �n r INSULATION PER N.Y. y STATE ENERGY CODE yy � FINAL ADDITIONAL COMMENTS aOO,00 �Z 13 012,1_' - V-1-ec-r'ic Cer+ o z D rb _ r o H rW z x d r� b H o�sofF0(,YcoG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� H x Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. l!! Building Inspector: MAY 1 0. qn99 Applications and forms must be filled out in their entirety.Incomplete , R 0 applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed. TOWN OF SOUTHOLD Date: OWNER(S)OF PROPERTY: Name: Alexander Sutton SCTM#1000-018.00-06.00-010.000 Project Address: 25500 Main Road, Orient, NY 11957 Phone#: 516-380-3301 Email: iiwac@optonline.net Mailing Address: P.O. Box 636, Southold, NY 11957 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454Email:_permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name: Glenn Graham Mailing Address:1981 Union Blvd, Bay Shore, NY 11706 Phone#: 631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171- Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION []NewStructure ❑Addition BAlteration ❑Repair ❑Demolition Estimated Cost of Project: 120ther 5-ka'- $ �{9,3`f 3•D t7 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? Dyes BNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes BNo IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Scott Maskin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) r SS: COUNTY OF Suffolk ) Scott Maski n being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 dlo Vo ary Public TAMMY LEA Notary Public,State of New York Registration No.01LE6410842 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION Commission Expires November 2,20A (Where the applicant is not the owner) Alexander Sutton residing at 25500 Main Road, Orient do hereby authorize Scott Maskin to apply on my be If to the Town Southold Building Department for approval as described herein. wner's Signature Date Alexander Sutton Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector 4O i TOWN OF SOUTHOLD CZ - own Hall Annex - 54375 Main Road - PO Box 1179 } =WING DEPT. - Southold, New York 11971-0959 • OF SOUTHOLD J;� Telephone (631) 765-1802 - FAX (631) 765-9502 0. rogerr so.utholdtownny.gov ._seand(c�southoldtownny.gov _ APPLICAPON FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permifting@sunation.com Address:_ 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Alexander Sutton Address: 25500 Main Road, Orient, NY 11957 Cross Street: Phone No.: (516) 380-3301 BIdg.Permit#: q4jb email: Tax Map District: 1000 Section: 018.00 Block: 06.00 Lot: 010.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs rot k�� BUILDING DEPARTMENT-Electrical Inspector !i TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 ._,,�,:.}.,�. -�*► Southold, New York 11971-0959 --� Telephone (631) 765-1802 - FAX (631) 765-9502 ? ...:_ .. seandaoutholdtownny.govrogerr(awov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/25/2021 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858=ME email: iPhone No.,_ 631-771-5152 01 request an email.copy of Certificate of Compliance Address..,, .Nprth Sea Road, Southampton, NY 11968 res... .., ., JOB SITE INPORMATf`ON, (All Information Required) Name: Robert Ruocco Address:, 310 Narrow River Road, Orient, NY i Cross Street: Phone No.: 516-383-5985 . BIdg.Permit#: �j�j;�� email: rruocco@gmail.com Tax Map District: 100.0 Section: 27 Block: 4 Lot: 9.4 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roofrmountdd solar electric system (16)SunPower SPR-A400-G-AC panels (16)SunPower SPR-A400-G-AC microinverters (1)SunPower monitor PVS6 System Size 6.400kW Check All That Apply:. Is job ready for inspection?: DYES ONO ❑Rough In ❑Final Do'you need a Temp Certificate?: ❑✓ YES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [—]Overhead # Underground LateralsD1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx 2 � 0 r ct, SUNATION ENERGY 0E.L'4.Ci 202 NG TDWAFO FSO®EFW U� r Hello, Enclosed are documents for permit close-out for upcoming/recent inspections. Thank you, Cecelia Polvere Closeout Coordinator closeout@sunation.com 1-11 REMINGTON BOULEVARD _ RONKONKOMA, Ronkonkoma, NY 11779 Office: 631-750-9454 Fax: 631-750-9455 SUNATION ENERGY CLICK HERE TO REFER A FRIEND OR FAMILY MEMBER s "IUN ® I[ Gln I� II IVI I� SUNAI eNERGY jAm 2 6 2023 E00 BUILDING DEPT n1n►n1ntc cni m4n1 n January 20, 2023 Hello, Enclosed are engineer's letters for permit closeout. Please feel free to reach out with questions. Best Regards, Tiffany Paolini closeout@sunation.com (631)750-9454 I 11 11 REMINGIT,ON BOULEINWIR4 .7. m o v NYS 1 F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 753118816 GCG RISK MANAGEMENT INC , 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBERPOLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIRECTOR,4SURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 Il�H�ll�iliI000�0�000110000�09940tl3304�11m1111111 Form WC-CERT-NOPWNT Vcmian 3(08/29/2019)[WC Policy-21606702] _ U-26.3 64 [oo000000000099ao3304](auoi-000021606702)[sa27[15782-a6][Cr�NoP-MT 1][01-00001) YCompensation workers' STATE CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1 a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/0112021 to 09/30/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described aove. Date Signed 12/1/2021 By 9wok (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) III III 111iiiiiiiiiiiiiuuiiiiiii�iiiiiiuiiiiiiiii1111111 ® DATE(MMDD/YYYY) A�o CERTIFICATE OF LIABILITY INSURANCE 2/11/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: The Horton Group PHONE FAX 10320 Orland Parkway AMAN Ext•708-845-3000INC.Noll: Orland Park IL 60467 ADDRIESS: certificates thehorton rou .com INSURER(S) AFFORDING COVERAGE NAIC# INSURERA:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER B:The Continental Insurance Company 35289 SUNation Solar Systems, Inc. 171 Remington Blvd INSURER C:Axis Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURER D:Travelers Property&Casualty Company of America 25674 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. /NSR TYPE OF INSURANCE ADOL SUER POLICY NUMBER MM DDYLICY EFF IMM UCDY/YYYY LIMITS LTRINSR Vivo A GENERAL LIABILITY Y Y MKLVlENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE $1,000,000 X DAMAGE TO RENTED COMMERCIAL GENERAL LIABILITY PREMISES Ea occurrenceS300,000 CLAIMS-MADE F�OCCUR MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 POLICY I X I PRO LOC S B AUTOMOBILE LIABILITY Y Y 7018308202 2/112022 2/11/2023 COMBINED SINGLE LIMIT Ea accident) $1,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) S AUTOS AUTOS NON OWNED PeOPER ntDAMAGE $ HIREDAUTOS AUTOS L $ C UMBRELLA LIARX OCCUR Y Y P-001-000795195-01 2/112022 2/11/2023 EACH OCCURRENCE $3,000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $3,000,000 DED I I RETENTIONS S WORKERS COMPENSATION OR I IMIT O R AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE[ N[--] NIA E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-630-2T010874-TIL-22 2/112022 2/112023 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional Insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD F Suffolk County Dept.of Labor,Licensing&Consumer Affairs f; MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN • f Business Name This certifies that the bearer Is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk License Number:ME-33412 Rosalie Drago Issued: 06/24/2003 Commissioner Expires: 06101/2023 I i i s li i 41 .., i a r i' r ' i f 1 4 i Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE ` at�'� Name �r'.a,• SCOTT A MASKIN Business Name • s certifies that the firer is duly licensed SUNATION SOLAR SYSTEMS INC :he County of suffolk License Number:H44104 Rosalie Drago Issued: 03/06/2008 Commissioner Expires: 3/1/2024 t e �• i I i i t I i i I I ® SERVICDISC METER p R 0P0SED R ESIDENTIAL PLAN KEY "0' SERVICE DISCONNECT PV1-0 COVER SHEET 0 SUPPLY SIDE CONNECTIOND Ai-1 PARTIAL ROOF PLAN I:'-AUTOMATICTRANSFERSWITCH DLL 302 HOTOVOLTAIC S A1-4 ROOF ACCESS PLAN 0-GAS METER S1-1 STRUCTURE ®-MAIN SERVICE PANEL B SIL DINGDEPr ©-SUB PANEL IMNOFSOU HOLD SUNATION SOLAR SYSTEMS NYSERDA 4355 E1-1 ONE-LINE DIAGRAM ! WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER , - E2-1 PV LABELS ®-INVERTER RONKONKOMA, NEW YORK 11779 NUMBER G1-1 PV PHOTOS 7-ENPHASE10COMBINER ®-PANEbPHOTOVOLTAIC FRONT OF HOUSE-FACING STREET OR DRIVEWAY Browne Residence ELECTRICVEHICLECHARGER 1400 Wunneweta Road, Cutchogue, NY 11935 -ENPHASEENVOY _ _— — AS-BUILT PLANS ®-SENSE CONSUMPTION MONITOR Drawn By. T. Passannante - 06/07/2022 -AC DISCONNECT li -TESLA GATEWAY ®-TESLA POWERWALL OF NFA -ENPHASEIOLOADCONTROLLER ACCESSQtn `�•F IQ QAC Roof �P\�� %r,5 FISHER ENGINEERING SERVICES, P.C. -ENPHASE 10 10 BATTERY t^ ®-ENPHASEIO3BATTERY (EXT) ss 509 Sayville Boulevard U® - Sayville, New York, 11782 Q-GENERATION PANEL � I � ...,•--. � Licensee No. 074659 ©-BACKED UP LOADS CENTER s � AccEss -Oi46 (631)-786-4419 5g,,�� O -VE"T%PE ROOF F -:� I@Fisher-NY.com -EXTERIOR LOCATION -18"-VENTILATION -1ST FLOOR LOCATION ACCESS ROOF -BASEMENT LOCATION Building Review Note -GARAGE LOCATION Town building examiner has received the enclosed document for minimum acceptable plan submittal requirements of the town as specified in the building and/or Residential 18"-VENTILATION Code of the State of New York. This review does not guarantee compliance with that PROPOSED PV SYSTEM Ei U code. that responsibility is guaranteed under the seal and signature of the New York Module Type/Qty: (16)REC405 Pure Black State licensed design professional of record. That seal and signature has been 77 0 interpreted as an attestation that,to the best of the licensee's belief and information ork in Module Dimension: 71.69"x 40"x 1.18" the Accurate this document is: Module Weight/PSF: 45 lbs/2.3 PSF Conforms with governing codes applicable at the time of submission • Conforms with reasonable standards of practice and with view to the Micro Inverter: (i6)Enphase IQ7A-72-2-US (4)PROPOSED PV MODULES safeguarding of life,health,property and public welfare is the responsibility of the (12)PROPOSED PV MODULES licensee. System DC Rating: 6.48 kW Estimated AC Production: 4,275 kWh/yr Structural Statement Production Source: Aurora • The existing structure is adequate to support the new loads imposed by the photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to IRC-2018 table R802.4.1(2)-Rafter Spans. PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be - provided where necessary. An in depth description of each applicable code APE,A RES;E reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PVImO COVER PAGE JOB# 22076 � ' REVISION # N/A ,C�� SUNatior REVISED BY N/A Solar as It should OF NFIy G.Fs 3 �' ��E W � D �0•074659�� FESSIONA� FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard Sayville,New York,11782 Licensee No.074659 (631)-786-4419 Bill @ Fisher-NY.com ♦ I / -U- SUNation / I ♦ Solar as It should be RIDGE CAPPING SUNation Solar Systems (TYP.) 171 Remington Blvd. Ronkonkoma,New York 11779 RIDGE (631)-750-9454 - 33'-8" NYSERDA INSTALLER R NUMBER 4355 , ROOF 1 JOB NUMBER RIDGE PHOTOVOLTAIC MODULE 22076 W --- - 32'"0/2" 8" (n ^ 0 - LO U1 rn N O ❑ I O El u } a N f Z Z - -- - Q�' 6'-5Y2" o m o CIRCUIT 3 CIRCUIT 2 X" . , a = = z CHIMNEY iv O y ROOF 2 cc N _ _ M °0 3 O -6t -, GUTTER ? 3cc 5 Cc 33'-10" -- W O t0 Q ROOF AREA CIRCUIT 1 m GUTTER 3 00 0 Attachment Spacing: Portrait Attachment Spacing: Landscape Roof#I Roof Description Modules Azimuth Tilt Pitch - Interior Edge Corner Interior Edge Corner 1 BOH Southwest Roof 4 2240 410 10.9/12 48" 32" 16" 64" 48" 48" 2 BOH Southwest Roof 12 1 2240 90 2.4/12 32" 16" 16" 64" 48" 32" A1 = 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS Cc)F NFA (NY) R324.6 Roof access and pathways. Roof access, pathways and ,�P om Fs setback requirements shall be provided in accordance with Sections �'� o R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof,to provide pathways - 4 to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. Exceptions: 1. Detached, nonhabitable structures, including but not limited to FISHER ENGINEERING detached garages, parking shade structures, carports, solar SERVICES,P.C. 509 Sayville Boulevard trellises and similar structures, shall not be required to provide Sayville,New York,11782 roof access. Licensee No.074659 2. Roof access, pathways and setbacks need to be provided (631)-786-4419 where the building official has determined that rooftop Bill@Fisher-NY.com operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two FRONT OF HOUSE - FACING STREET OR DRIVEWAY units vertical in 12 units horizontal(17-percent slope)or less $UNation Solar as It should be [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches on Remington Blvd. Ronkonkoma,New York 11779 (914 mm) wide, shall be provided on all buildings. Not fewer than one (631)-750.9454 pathway shall be provided on the street or driveway side of the roof. -For each roof plane with a photovoltaic array, a pathway not less than 36 inches (914 mm) wide shall be provided from the lowest roof edge NYSERDA 43551 INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. ACCESS Pathways shall be over areas capable of supporting fire fighters IQ AC ROOF JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal (EXT) - DSC - obstructions such as vent pipes, conduit, or mechanical equipment. SSCM MSP' (B) 22076 Pathways on opposing roof slopes shall not be located along the same = plane as the truss, rafter, or other such framing system that supports the pathway. ACCESS Exception: ROOF 18"-VENTILATION LO 1. Access pathways shall not be required on roof slopes containing ACCESS rn photovoltaic modules, panels, or an array where the opposing ROOF o or adjacent roof slope is an access roof. z N - - Z Access Roof-A roof surface that: CO H � m o - 18"-VENTILATION Q a a =' 1. Can be accessed from the ground by the fire service. v d m 2. Is capable of providing fire service access to the ridge or peak O Jc of an opposing or adjacent roof surface that contains VVLL 0 5 U) photovoltaic modules,panels,or an array. 7 3 Q � a 3. Is relatively free of vents,skylights,conduits, mechanical w oro aH m iv equipment and other such obstructions. Cl) 4. Does not contain photovoltaic modules, panels or an array, or is m a single ridge roof where the maximum edge to edge width of the photovoltaic panel system does not exceed 33 percent of o 0 (4)PROPOSED PV MODULES o the ridge length. (12) PROPOSED PV MODULES v [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm) wide shall be provided to ` the emergency escape and rescue opening. I A1 =4 ROOF ACCESS PLAN OF NFIy Typical Attachment Method ,om G./,. {0 pa. /'0 RIDGE SNAP'N'RACK ULTRA RAIL ` L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING PHOTOVOLTAIC 711'-6" SERVICES,P.C. MODULE 509 Sayville Boulevard ® Sayville,New York,11782 Licensee No.074659 3/4" MODULE SPACING (631)-786-4419 BETWEEN ROWS AND Bill@Fisher-NY.com (2)S.S.304 S.OMM X 90MM COLUMNS (TYP.) WOOD SCREW FASTENER p 100, -- SUNation RT-MINI ROOF Solar as It should be ' ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER SHINGLE(TYP.) / / NUMBER 4355 NYSERDA 2" x 6" / 24" O.C. JOB NUMBER 22. 076 PLYWOOD DECKING (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP') WALL ATTACHMENT TYPE APPLIED TO-ROOF'TYP' 10'-11.25" LO N ROOF SECTION (TYP.) - ROOF "1&2" o SCALE: N.T.S. z Z3 Z SOLAR MODULE FRAME U 0 U ' NOTE:3/4'SPACING IF U Z Roof# Rafter Size/Spacing Max Span Material Layers Sheathing BETWEEN MODULE ROWS a a- AND COLUMNS. � � U � � ty 1 2"x 6"/24"O.C. 4'-5.5" Composite Shingles 1 Plywood s"5• HEIGHT ADJUSTABLE � L-FOOT(TYP.) Z N MO 2 2"x 6"/24"O.C. 10'-11.25" Mod-Bit 1 Plywood ENDPM ;LAMP F o Q SNAP'N'RACK N CO Q) f"" 6.0' ULTRA RAIL l� (TYP-) Q) m HEIGHT OFF OF j ROOF SURFACE ` 5 � i RT MINI Q 0 (TYP-) o Typical Module PEST WRAP CUT It AWAYFOR Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX S 1 1 SPEED(MPH.) SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE LOAD EFFECTS ZONE _ 20 PSF 140 B C 2 B SEVERE 3'-0" MODERATE TO 15 DEG NIA SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE OF NFy, G.F,s s ��a ��•Ci4659 ��� FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard Enphase A/C Branch Circuit (typ.) Sayville,New York,11782 . . . . . . . 120/240v Licensee No.074659 UTILITY (631)-786-4419 SERVICE Bill C&Fisher-NY.com ti N Enphase Microinverter(typ.) ti N r � .� COMBINER -(5- SUNation Module J-Box(typ.) PANEL SUPPLY-SIDE / I Solar as It should ba CONNECTION SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 ERDA IN S ALLEA355 EGC Attached To Rail(typ.) 200A \ INSTALLE MAIN /) NUMBER Enphase Envoy 5 JOB NUMBER (No roads.monitoring w*) s �. 22076 2P� CONDUIT AND CONDUCTOR SCHEDULE 2P20A E — ENPHASE BRANCH CIRCUIT#1 Cscuit#1 TAG CONDUCTOR CONDUIT RUN - ENPHASE BRANCH CIRCUIT#2 C P A#2 60A 1 TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#3Zp�A MAIN J s 1 Enphase O-Cable 12 6 N/A N/A 15' EGC - Circuit Lr) G G G Cy')2 Type NM 10 6 N/A N/A 65' MAIN °' CSI 3 HWN-2 10 6 PVC SCH.80 1.25" 15' 1 2 3 ENPHASE A/C SERVICE r N IQ COMBINER DISCONNECT PANEL } N GC 8 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR SERVICE RATED z 1` 4 HWN-2 6 3 PVC SCH.80 1.25" 5' 4 ENCLOSURE s a� 0 GC 8 1 PVC SCH.80 1.25" 10' — MIN.60A — cc MIN.22k AIC Z O O7 O 5 HWN-2 6 3 PVC SCH.80 1.25" 10' O o Cf) 6 GC 6 1 N/A N/A 10' BUILDING Q Q GROUNDING —I ELECTRODE U a- 0 0 7U. J C (� ? O m v7 Circuit# PV Module Qty Micro-inverter Qty. Maximum AC Operating Current F 3 Er 1 REC405 Pure Black 10 Enphase IQ7A-72-2-US 10 14.5 A Q N m � I-- 2 REC405 Pure Black 6 Enphase IQ7A-72-2-US 6 8.7 A m c � CD Q 0 T Maximum AC Operating Current(Total) 23.2 A E1 =1 ONE-LINE DIAGRAM LABEL LOCATION: F LABEL LOCATION: WARNING: • • • CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS ServiceDisconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE } �' `^ -7- CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. POWERSOURCE NEC 2017 690.31(G)(3) NEC 2017 705.10 a °074659 a a DISCONNECT LABEL LOCATION: Sec• • • t to Meter Pan MAXIMUM AC•• SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Located FISH9 ENGINEERING NOMINAL OPERATING CURRENT VALUES ON DISCONNECT LABEL. SERVICES,P.C. 509 Sayville Boulevard NEC 2017 690.54/NEC 2017 690.13(B) Sayville,New York,11782 NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 THE BUILDING MAIN SERVICE DISCONNECT. (631)-786-4419 IlkBill(P Fisher-NY.com WARNING This building is equipped with an r Interconnected Electric Power 0 SUNation Production Source Solar as it should be • • REMOVE SUNation Solar Systems ELECTRIC SHOCK HAZARD Source Type: 171 Remington Blvd. DO NOTLS Ronkonkoma,New York 11779 TERMINALS ON BOTH THE LINE ANDDisconnect Solar Photovoltaic Disconnect is Located: Interior (631)-750-9454 LOAD SIDES MAY BE ENERGIZED ServiceLocated in Main Panel Basement Garage: Exterior NYSERDA 4355 IN THE OPEN POSITION Front Rear:__ LH Side • • •LTAC SYSTEM INSTALLER PHOTOVOLTAIC MODULES PRODUCEDC VOLTAGE RH Side ._ Other Location. _ NUMBER wrovEUERTHEY ARE E:cPOE°T°suNLIc'ff SUNation Solar Systems ' JOB NUMBER 631-750-9454 EQUIPPED www.sunation.com SHUTDOWN22076 I0 M N rN >- N Z -I--_ 0) � O V O r Q -0a) C CzJ r— � O U H C 0 � -0 c15 ZC 0 EDto co 30 (Z Q L- M O � C 00 C C: > Cz O Q O T E2= 1 PV LABELS OF NFA G AM FISHER O&GINEERING SERVICES,P.C. • - a ,. �q�• ,- `B.. t ' _ v.� i,". / '�- 509 Sayville Boulevard Sayville,New York,11782 Licensee No.074659 1-• (631)-786-4419 Bill@Fisher-NY.com . SUNation Solar as it should be r "+= SUNation Solar Systems f' t 171 Remington Blvd. . - — Ronkonkoma,New York 11779 . + — (631)-750-9454 ww IN S 4355 !� ,r" — INSTALLER NUMBER JOB NUMBER 22076 ARRAY LOCATION(S) ARRAY LOCATION'S) SATELLITE IMAGE VIA GROUND VIA ROOF co O (V T r N O -— c7 r.�.�.�r.. CV 0) CY) O t 74 Q ' Cz t y f ! O Cz a N W Cz O Q O T SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 = 1 PV PHOTOS 0 4� AP ROVED AS NOTED DATE: P.# FEE: BY:_ ELECTRICAL NOTIFY BUILDINGPARTMENT AT 765-1802, 8 AM TO 4 PM FOR THE INSPECTION REQUIRED FOLLOWING INSPECTIONS: 1. FOUNDATION - T'WO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE F;Dk C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. 6, A 6 a� � COMPLY WITH ALL CODES OF j al !fie (' '-,a-d`'�y NEW YORK STATE & TOWN CODES CCe.Snb�,� AS REQUIRED AND CONDITIONS OF OL SQJHER-�PCAnINfNG BOARD Seu-��RUSTEES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY t Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Building Consultants & Expeditors (631)665-9619 May 13, 2022 Town of Southold D �� [ Building Department MAY 1 9.?112 54375 Rt. 25 Southold, NY 11971 BUILDING DEPT. TOWN OF SOUTHOLD Re: Sutton Residence 25500 Main Road Orient, NY 16.79 KW Rooftop Solar Photovoltaic Systems To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-10 If you have any further questions, do not hesitate to call. 4' Rb _LOLL iY T unn RA f� , d 1 1 sndloNd I'; I Nv3ASZ pieme 4�ejos09C `� � S,sy :., ;'m, _- I Y% s3IN3S )OHd V. -D-3 I m== ' ---�- I- Vis' F�•'�r+ MEN 33 V l o � `r RCC PRODUET DATA5HEtET SOLAR'S MOST TRUSTED RKALFHASERIES>��': I CERTIFICATIONS 1721±2.5[67.8±0.11 IEC 61215:201,13,IEC 61730301�67�17"0'3,UL 61730 _28[1.]] 802[31.6] _A55[17.9] I E C6280.4 PID ............................................................ 1EC61701Salt Mist + IEC 62716 ...........Ammonia-Resistance ...-.. . . .......... 1000[39.41 UL 1703 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 612I5-2:2016 Hailstone(35mm) AS4040.2 NCC 2016 Cyclic Wind Load ........................_.............I................ +of Ni o v ISO 14001:2004,ISO 9001:2015,OHSAS 180012007,IEC 62941 cd 41 O_ CE ❑EO of NO 11±0.2 lnte�k [0.43±0.01] ✓ K WARRANTY _ Standard: RECProTrust .......... ............. ................. Installed by an REC Certified 20.5±0.5 No Yes Yes Solar Professional a [0.8±0.02] ........................I.... .................. ................ I sit 1200[47.21 . .......... '7 System Size All : E25 kW 25-500 kW ........... ................... Product Warranty(yrs) 20 25 25 ............................................................................................ a 45[1.81 22.510.91 621±3[24.5±0.12] ­R ow erWa.rra-n.ty-(yrs) 25 ...........25 25 .........................10... 130[1.2] Labor Warranty(yrs) 0-.......... .2..5........ ...­_­ Measurements in mm[in] Power in Year 1 98% :..._.98% 98% ........... ...... . GENERAL DATA Annual Degradation 0.25% 0.25% 0.25% 120 hatf-cut bifacial cells with REC Power in Year 25 92% 92% 92% StgubtiMC4PV-KBT4/KST4,12AWG(4mm2) See warranty documents for:details.Conditions apply. Celltype: heterojunction celitechno[ogy Connectors: in accardancewith IEC 62852 6 strings of20 cells in series IP68 onlywhen connected ...................I....................................................I.............. ............................................. -... ..................... MAXIMUM RATINGS 0.13 in(3.2 mm)solar glass with 12AWG(4mm2)PVwire,39+47in(l+]2m) Glass: Cable: Operational temperature: -40...+85*C a nti-reflection su rfa ce treatm entaccordance with EN 50618 ..........................­­............ ............ ................................................. ............................... ............... .........I . .. -............. . . .... ............................................. Maximum systernvoltage: 1000V Backsheet: Highlyresistant Dimensions: 678x40xl.2in(1721x1016x30mm) ............................................ ........................................­ polymeric construction Design load(+):snow 4666 Pa(975 lbs/sq ft)* ........................................................................... ................11...............I.......................................................................... Maximum test load(+): 7000 Pa(146 lbs/sq ft)* Frame: Anodized aluminum Weight: 43 lbs(19.5 kg) ............................. ............................................................................ . . . . ­­ . ............................................ ................. ..................... .................................................................................... Design load(-):wind 2666 Pa(55.6 lbs/sq ft)* 3-part,3 bypass diodes,IP67rated - . . Maximum test load 4000 Pa 83.5lbs ft Junction box: * aj in accordance with IEC 62790 Origm: Made in Singapore (+ ( / .............I................ .............................................................q ) ....... Max series fuse rating: 2SA ELECTRICAL DATA Product Code*:RECxxxAA .................................................. ..................................................... Max reverse current: 25A Power Output-Pmgx(Wp) 360 365 370 375 380 'Calculated usinga safety factor ofl.5 'See installation manual for mounting instructions Watt Class Sorting-(W) -0/.5 -0/+5 -0/+S -0/+5 -0/+5 . . ......... . .......... .......- ........ ................................ .........­­............ .............. ................................. Nominal Power Voltage-Vmpp(V) 36.7 37.1 37.4 37.8 38.1 TEMPERATURE RATINGS* t Nominal Power Current-Impp(A) 9.82 9.85 9.90 9.94 9.98 Nominal Module OperatingTemperature: 44°C ±2°C ............................................................... . ......... . .......................... ...... ......... ................... ...............I......................................................................... Open Circuit Voltage-Voc(V) 43.9 44.0 44.1 44.2 44.3 Temperature coefficient OfPMAX: -0.26%/°C I..................... ........................................................................... o .............. .................. ........... ..... ................................................................................................I............................ Z Short Circuit Current-Isc(A) 10.491052 10.55 10.58 10.61 Temperature coefficient of Vac: -0.24%/°C . .............. .... ............................... ...................................................... ............................... ...................................... ........I.................................................... Power Density(W/sq ft) 19.1 19.4 19.7 19.9 20.2 Temperature coefficient of1sc: 0.04%/°C K Ln Panel Efficiency(%) 20.6 20.9 21.2 21.4 21.7 'The temperature coefficients stated are linearvalues LIGHT BEHAVIOUR Power Output-PM,x(Wp) 274 278 282 286 289 .. . .... ........ . . ............. .............. ........... . ...... ................................... Typical low irradiance performance ofmodule at STC: C) Nominal PowerVoltage-Vmpp(V) 34.6 35.0 35.2 35.6 35.9 2 .. ............ ............................................... . ........... Z Nominal Power Current-Impp(A) 7.93 7.96.... 8.00 8.03 8.06 .. ........I............... ........ ........ ...... Open Circuit Voltage-Vo,(V) 41.4 41.5 41.6 41.6 41.7 ... ........ ... .................................................... ..................................................................... -----------------I---------- -------- Short Circuit Current-Isc(A) 8.47 8.50 8.52 8.55 8.57 --------------- -------- Values at standard test conditions(STC:air mass AM I.S.irradlance 10.75 W/sq ft(1000 W/M2),temperature 77*F(25*C),based on a production spread with a tolerance of P,.,Voc&Isc±3%within one watt class.Nominal module operating temperature(NM OT:air - - - - - - - - - mass AM 1.5,irradiance 800 W/M2,temperature 68°F(20*C),windspeed 3.3 ft/5(I m/s).`Where xxx indicates the nominal power class Irradlance(W/M2) of (P..)at STC above.Bifaciality coefficent of up to P_-4%. REC Group is an international pioneering solar energy company dedicated to empowering consumers with REC clean,affordable solar power in order to facilitate global energy transitions.Committed to quality and innovation,REC offers photovoltaic modules with leading high quality,backed by an exceptional low warrantyclaims rate ofiess thanlOOppm.Founded in Norway inl996,REC employs2,000 people and has an annual solar panel capacity ofl.8 GW.With over`10 GW installed worldwide,REC is empowering more than 16 million people with clean solar energy.REC Groupisa B[uestar Elkem companywith headquarters in Norway, operational headquarters in Singapore,and regional bases in North America,Europe,and Asia-Pacific. www.recgroup.com a tData Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro'"" and Enphase IQ 7+ Micro'M Q 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'M, Enphase IQ Battery'M, and the Enphase Enlighten'"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) i Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing Class II double-insulated enclosure UL listed 0 Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com %W00EN PHASE. y f • A Enphase IQ 7 and IQ 7+ Microinverters a INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V . Peak power tracking voltage 27V-37V 27V-45V Operating range 16 V-48 V. 16V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A, 15A Overvoltage class DC port II II DC port backfeed current 0 A' 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuitfault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III IIP AC port backfeed current 18 mA 18 mA Power factor setting 1.0, 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6°i° 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connecfortype MC4(or Amphenol H4 UTX with additional Q-DCC 5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double insulated,corrosion resistant polymeric enclosure_ Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) .. Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means. The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits mayvary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com EN PHAS Ea .00 ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 SERIES 100 SnapNrackFLASHED L FOOT KIT PV Mounting Systems The SnapNrack line of solar mounting t's�3'aS1�->c:.4 `%�?_�i:t .�;_.•.a:* ..�.:is v.r;r.•. _�T1�• 'S+,'; S P:4}' 4.�r,•:::^/Ay. f o'T :w n```i':;Y::;' _:4-It::�',i •':-d•• l•': r.:rT�'- i:• ne desi is systems d to reduce total Y g �� >z.'.'.`,�ti�.:.3 � �84�;}"«�� �°ie j.,�'v r`_<.;}•�% fc;,1•�?°J.;• `r.l +.� .�r >�ntl�t''v i r .FL'• :.�:W Ja."''t�;3.:�C{•K;:i�• �': "'r_'�•�:^•'.'Y- 'rr�'9•sr� installation costs. The system features yF` diEti�'h `�Z. technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. p, r Flashed L Foot Simplified `:8 ,y SnapNrack Series 100 Flashed L Foot Kit is an innovative ' h solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) I distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending pW N(DUU <a Z JBROMO I i Flashed-L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions rSNAPNRACK CHANNEL NUT .-SNA➢NRACK 92 DEGREE L-FOOT,CLEAR 5/1618 FLANGE NUT �5/16-18%11N BOLT WITH vl. SPIT LOCK WASHER -SNAMRACK COMPOSITION FLASHING \QPo 1pO�. 3.43 '-SNAPNRACK L-FOOT BASE SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship S n a p l�� rack (877) 732-2860 www.SnapNrack.com Cj Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. 6 SERIES 100 ROOF • SnapWacl Solar • Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical ; innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. : Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) rte.:}{i'Ya,,..«vn _ ..A?�",�tiw".-,:`:'S:.t:✓i.'w`.'s':x.ra.rtL%v...i.•�.. ):`}`-.:..:Jsss module installation system.Series 100 UL is Listed ( to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, f 2) Identify Site Conditions (Array Tilt, Building and bonding jumpers between splices.The UL 2703 Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules j` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrackBonding �`' g see Clamp Top Mid Clamp SnapNrack SnapNrack Bonding ar Bonding SnapNrack Stainless Adjustable End _ Bonding Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lack Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG f Copper Wire — SnapNrack Ground Lug Assembly a (ONE REQUIRED PER ROW OF • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap ����! UEC Wedge Stainless Steel Bolt s , with Flat Washer IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar �p Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack 'a� Stainless SnapNrack Flange Mill Finish 92 Degree L Foot Bolt Standoff ;® 4 SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shawn) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack • • UL Technical Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) SnapKllrack- Solar (877) 732-2860 www.SnapNrack.com 'a Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. ®-SERVryDISC - PROPOSED RESIDENTIAL PLAN KEY ®-SERV CE DISCONNECT COVER SHEET 9 SUPPLY SIDENN Al-1 PARTIALROOFPLAN ®'AUTOMATICTRANSFER SWITCH PHOTOVOLTAIC S A14 ROOF ACCESS PLAN B_GAS METER ®-MAINSERVICEPANEL (3)PROPOSED PV MODULES S1-1 STRUCTURE SUNATION SOLAR SYSTEMS NYSERDA 4355 ®-SUB PANEL Q-WIRELESS ROUTER E1-1 ONE-LINE DIAGRAM 171 REMINGTON BOULEVARD INSTALLER E2-1 PV LABELS ®-INVERTER RONKONKOMA,NEW YORK 11779 NUMBER G1-1 PV PHOTOS ®. -ENPHASENICOMBINER f3)PROPOSED PV MODULES Sutton Residence ®-PANEL PHOTOVOLTAIC ___ ___ _ (3)PROPOSED PV MODULES Q•ELECTRIC VEHICLE CHARGER - 25500 Main Road, Orient, NY 11957 ®-ENPRASE ENVOY / ROOF ROOF Drawn By: R. Butera-05/13/2022 ®-SENSE CONSUMPTION MONITOR ACCESS ACCESS -36'- ®-AC DISCONNECT ATG' Q-TESLA GATEWAY ®-TESLA POWERWALL -Is"-VENTILATION 18"-VENTILATION / �"TEG`T ©'-ENPHASE IO LOAD CONTROLLER -18"-VENTILATION -13"-VENTILATION ❑ / ROOF uNN ( ®-ENPHASE 1010 BATTERY . ACCESS MAY 19 2022 ®-ENPHASE 103 BATTERY R(CESS ACCEF �Z Ilk ®-GENERATION PANEL T \ O ®-BACKED UP LOADS CENTER BUILDING DEPT. AC&ESS 1e"-VENTILATION �� y B-VENT PIPE $61e"-VENTILATION EXTERIOR LOCATION -•//./ TOWN OFSOUTHOLD _ t> m- IST FLOOR LOCATION I I V Ly C3 AREA RESERVED FOR PZ.-BASEMENT LOCATION (4)PROPOSED PV MODULES _ I O p I M> A SFS S � i�" w Note -GARAGE LOCATION H H -n a I IIiH ng examiner has received the enclosed document for minimum acceptable M Z Z I plan submittal requirements of the town as specified in the building and/or Residential PROPOSED PV SYSTEM Code of the State of New York. This review does not guarantee compliance with that LU w � (3)PROPOSED PV MODULES code. that responsibility is guaranteed under the seal and signature of the New York Module Type/Q 46 REC365AA Om m b State licensed design professional of record. That seal and signature has been YP Qty: ( ) I interpreted as an attestation that,to the best of the licensee's belief and information _ the work in this document is: Module Dimension: 67.76"x 40"x 1.18" o I �� Accurate Conforms with governing codes applicable at the time of submission Module Weight/PSF: 43 lbs/2.2 PSF m M 'l I �} •(5)PROPOSED PV MODULES Conforms with reasonable standards of practice and with view to the T (e) safeguarding of life,health,property and public welfare is the responsibility of the Micro Inverter: (46)Enphase IQ7PLUS-72-2-US > , I (EXT) licensee. System DC Rating: 16.79 kW Z I I ATS s G - ROOF - Structural Statement (n ACCESS Estimated AC Production: 13,975 kWh/yr A � -w_ DS • The existing structure is adequate to support the new loads imposed by the Production Source: Aurora m €€ photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to IRC-2018 table R802.4.1(2)-Rafter Spans. 0 (11)PROPOSED PV MODULES (12)PROPOSED PV MODULES J PV Notes m 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground < - clearance,roof access points,access pathways and ventilation systems shall be - --- provided where necessary. An in depth description of each applicable code AREA RESERVED FOR AHJ: reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. �1 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PVImO COVER PAGE JOB# 21477 REVISION # N/A 1— SUNati® �' Solar as it should be REVISED BY N/A SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and ', pta77 setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof,to provide pathways ,r to specific areas of the roof, provide for smoke ventilation opportunity "r � areas and to provide emergency egress from the roof. Exceptions: = 02C' 1. Detached, nonhabitable structures, including but not limited to (3)PROPOSED PV MODULES detached garages, parking shade structures, carports, solar trellises and similar structures, shall not be required to provide roof access. 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop (3)PROPOSED PV MODULES operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two __ ____ ———— —— (3)PROPOSED PV MODULES ®. SUNation units vertical in 12 units horizontal(17-percent slope)or less - [ ® Solar as It should be [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar Systems R 171 roof planes from lowest roof edge to ridge and not less than 36 inches ROOF ACCESS Ronkonkoma,Remington Yo k1 m 1779 (914 mm)wide,shall be provided on all buildings. Not fewer than one ACCESS -36°- (631)-750-9454 .3s°- pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, a pathway not less than V\] 36 inches (914 mm)wide shall be provided from the lowest roof edge IN SALLE 435 5 to the ridge on thee same roof plane as the photovoltaic array, on an -18"-VENTILATION -18"-VENTILATION NSTALLER NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. -18"-VENTILATION -18"-VENTILATION ❑ Pathways shall be over areas capable of supporting fire fighters ROOF JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal VVVR96F R F ACCESS obstructions such as vent pipes, conduit, or mechanical equipment. CEss ACCE VVV 21 477 -3s- �s°- Pathways on opposing roof slopes shall not be located along the same plane as the truss, rafter, or other such framing system that supports the pathway. OF -18"-VENTILATION AC SS -36°- -18"-VENTILATION Exception: 1. Access pathways shall not be required on roof slopes containingVVV-7 photovoltaic modules, panels, or an array where the opposing I Z Z ❑ ROOF Lo a or adjacent roof slope is an access roof. (4)PROPOSED PV MODULES I _O _O Access °' o F ❑ .36° Z r N > 0 Access Roof-A roof surface that: T g g „Z LO V� Z Z Q o LD 1. Can be accessed from the ground by the fire service. Z 1 > j Z 2. Is capable of providing fire service access to the ridge or peak —1 1 1 1 (3)PROPOSED PV MODULES O CC of an opposing or adjacent roof surface that contains O 1 °� °� I Z c o m photovoltaic modules,panels,or an array. I cc Cd 3. Is relatively free of vents,skylights,conduits,mechanical p > > equipment and other such obstructions. N > LO 4. Does not contain photovoltaic modules,panels or an array,or isrn MU� o a single ridge roof where the maximum edge to edge width of I i (e) 1 (5)PROPOSED PV MODULES a the photovoltaic panel system does not exceed 33 percent of -n > the ridge length. n I i (EXT) z 1 I ATS SS [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be G) ROOF r located less than 18 inches(457 mm)from a horizontal ridge. Cn AC > AC CESS 1 C M[NY] R324.6.2.2 - Emergency escape and rescue opening. Panels m IQ=s M and modules installed on dwellings shall not be placed on the portion --I of the roof that is below and emergency escape and rescue opening. 0 (11)PROPOSED PV MODULES A pathway not less than 36 inches(914 mm)wide shall be provided to ` the emergency escape and rescue opening. (12)PROPOSED PV MODULES M D A1 =4 ROOF ACCESS PLAN �AITECT Typical Attachment Method N o) C, p2 RIDGE SNAP'N'RACK ULTRA RAIL PHOTOVOLTAIC 13'-6" �L-FOOT AND RAIL ASSEMBLY MODULE 3/4"MODULE SPACING BETWEEN ROWS AND (2)S.S.304 5.OMM X 60MM B COLUMNS(TYP.) WOOD SCREW FASTENER S ar■Nation RT-MINI ROOF solar as It should be ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER ASPHALT o NYSERDA 4355 INSTALLE 2" X 6" / 16" O.V. SHINGLE(TYP.) o // NUMBER R JOB NUMBER 21477 PLYWOOD DECKING (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP.) WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" 10'-2" owl — ROOF SECTION (TYP.) to N SCALE: N.T.S. � M Z N z SOLAR MODULE FRAME O to NOTE:3/4"SPACING O BETWEEN MODULE ROWSco Q Roof# Rafter Size/Spacing Max Span Material Layers Sheathing I T AND COLUMNS. 0 1 2"x 6"/16"O.C. 10'-2" Composite Shingles 1 Oriented Strand Board 6'6" HEIGHT ADJUSTABLE � CC L-FOOT 9YP.) Z C: Q m 2 2"x 6"/16"O.C. 9'-9.5" Composite Shingles 1 Oriented Strand Board END CLAMP w RYP-) ~ C 3 2"x 6"/16"O.C. 6'-9" Composite Shingles 1 Oriented Strand Board � � !4--SNAP 7J'RACK — N ((] 60" ULTRA RAIL 4 2"x 6"/16"O.C. 6'-7.5" . Composite Shingles 1 Oriented Strand Board (rYP-) 1 CZ HEIGHT OFF OF to 5 2��x 6i�/16��O.C. 61-511 Composite Shingles 1 Oriented Strand Board to 0 ROOFSURFACE 6 2"x 6"/16"O.C. 6'-6.5" Composite Shingles 1 Oriented Strand BoardN RT MINI 2 ITYP.) Typical Module PEST WRAP CUT AWAY FOR Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE UNDEQUIREDNT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE g 1 1 SPEED(MPH.) SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED LOAD EFFECTS ZONE 20 PSF 140 B NO 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PIANS 599 51 HEAVY EXAMINER STRUCTURE ITEc�. o NN 01 S , , Enphase A/C Branch Circuit(typ.) 120/240v UTILITY SERVICE N Enphase Microinverter(typ.) EXISTING COMBINER m Module J-Box 4 FPANEL (typ.) SUNati®� SUPPLY-SIDE ® I Solar as It should be . . . . CONNECTION ` � . F l SUNation Solar Systems 171 Remington Blvd. PV Module typ. Ronkonkoma,New York 11779 (631)-750-9454 200A 1 200A 1 EGCAttached ToRall(typ.) MAIN J MAIN J NYSERDA 4355 Enphase Envoy INSTALLER (No loads,monitoring only) 5 NUMBER JOB NUMBER 2P20A 2P15A Circuit#, Envoy 21477 CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 2P20A Circuit#2 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 2P20A 1 I circ ENPHASE BRANCH CIRCUIT#3 80A uit#a J TYPE GAUGE QUANTITY TYPE SIZE LENGTH MAIN ENPHASE BRANCH CIRCUIT#4 2P20A � � Circuit#4 1 Enphase Q-Cable 12 8 N/A N/A 15' 2 Type NM 10 8 N/A N/A 30' EGC G ,01-FG G G 2 3 MAIN ENPHASE A/C AUTOMATIC SERVICE 3 HWN-2 10 8 PVC SCH.80 1.25 15 TRANSFER GC 8 1 PVC SCH.80 1.2511 ROOF ATTIC EXTERIOR 15' IQ COMBINER DISCONNECT SWITCH PANEL 4 HWN-2 4 3 PVC SCH.80 1.25" 10' SERVICE RATED 4 ENCLOSURE 6 LA N MIN.100A GC 8 1 PVC SCH.80 1.25" 10' MIN.22k AIC �p 5 HWN-2 3 3 PVC SCH.80 1.25" 10' BUILDING } M 6 GC 6 1 N/A N/A 10' GROUNDING Z Z ELECTRODE Q U } LO H O Q ' "i cis 0 Z Cz 107 Circuit# PV Module Qty Micro-Inverter Qty. Maximum AC Operating Current CC OC 1 REC365AA 11 Enphase I07PLUS-72-2-US 11 13.31 A N U) m 2 REC365AA 12 Enphase IQ7PLUS-72-2-US 12 14.52 AC) 3: LO 3 REC365AA 13 Enphase I07PLUS-72-2-US 13 15.73 A N 4 REC365AA 10 Enphase IQ7PLUS-72-2-US 10 12.1 A Maximum AC Operating Current(Total) 55.66 A El =1 ONE-LINE DIAGRAM LABEL LOCATION: LABEL LOCATION: A® PHOTOVOLTAJC CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS S;ervice Disconnect * MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE U N _ CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. yy SOURCE NEC 2017 690.31(G)(3) NEC 2017 705.10 t 7 <' o (� 3Yy LABEL LOCATION: Second Disconnect •• - SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND • -• • • • _ CURRENT VALUES ON DISCONNECT LABEL. v rAT ` NEC 2017 690.54/NEC 2017 690.13(8) NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO d THE BUILDING MAIN SERVICE DISCONNECT. This building is equipped with an Interconnected Electric Power 1 W • ENING - . ) suN�ti®�, Production Source ® ( ® Solar as it should be ELECTRIC SHOCK HAZARD �. iNOT REMOVE THIS TAG SUNation Solar Systems Source Type: 171 Remington Blvd. DO NOT TOUCH TERMINALS Solar Photovoltaic Ronkonkoma,New York 11779 • (631)-750-9454 TERMINALS ON BOTH THE LINE AND Disconnect is Located: Interior. LOAD SIDES MAY BE ENERGIZEDLocated Service Basement_ Garage:_ F�cterior._ NYSERDA435 5 IN THE OPEN POSITION Front:_ Rear._ LH Side:_ I PHOTOVOLTAIC INSTALLER PHOTOVOLTAIC M ODI n PRODUCE DC VOLTAGE RH Side:_ Other Location: 3 NUMBER WHENEVERTHEYAREE)(POEDTOSUNUGHr SUNation Solar Systems i EQUIPPED WITH RAPID 631-750-9454 ,• JOB NUMBER www.sunation.com --�- - 21477 LO N O r CV �- co Z CU Z O 'r LO O Q N i cD fx 0 Z C C Cz 120 LLI O cc lY N U rn C OCz L0 i N E2- 1 PV LABELS u �• �1N a --r •.I :i,'' -.+^mac N. �. � ... 1'. .2r. - /J :•-C�r.•%^ .yam \.Vi:.-.+::.{ a� IL h�170 t Orient `•.�'?f�,''o rT�a..` :_. '` +'.`�!:, .sSa�i,�c',t,YEp t1 f r*_r:�•�ti,K SUNati®n Solar as It should be 41 SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 ' ;�4' •i-a ; -':� �... r,-y_.:�.; w:: ��� (631)-750-9454 r NYSERDA 4. � L INSTALLER l 7`� \'^; .; "'tip, 'a _ •'�.'.-'-- ' •-''=' NUMBER 4355 s j`4'•x JOB NUMBER 21477 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF InN 0) N M to C) O cz ILL :3 co LU Ir cc CO O 3t 0 cu to r���•z. :",: n� �, - - -meq �_-_ iP'�-s::,i,- : y =i^ ..'`v� _- Ln ❑ 04 SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 =1 PV PHOTOS