Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
47615-Z
g11fFD1,f'QoG Town of Southold 1/23/2023 y� P.O.Box 1179 0 o • �� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43781 Date: 1/23/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3505 Delmar Dr, Laurel SCTM#: 473889 Sec/Block/Lot: 125.4-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/1/2022 pursuant to which Building Permit No. 47615 dated 3/29/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Carrillo,Leivy&Ors. of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47615 1/18/2023 PLUMBERS CERTIFICATION DATED ut ori a Signature X` TOWN OF SOUTHOLD o�SUFFot c� BUILDING DEPARTMENT . y x TOWN CLERK'S OFFICE "may • �� SOUTHOLD, NY �L BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47615 Date: 3/29/2022 Permission is hereby granted to: Carrillo, Leivy 3505 Delmar Dr Laurel, NY 11948 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 3505 Delmar Dr, Laurel SCTM #473889 Sec/Block/Lot# 125.-4-5 Pursuant to application dated 3/1/2022 and approved by the Building Inspector. To expire on 9/28/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pv SO!/TyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a sean.devlina-town.southold.ny.us Southold,NY 11971-0959 Q �y�OUNTI,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lelvy Carrillo Address: 3505 Delmar Dr city:Laurel st: NY zip: 11948 Building Permit#: 47615 Section: 125 Block: 4 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunrun Installations License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed.Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 8.5kW Roof Mounted PV Solar Energy System w/ (25) JAM60S10-340 Modules, AC Disconnect, DC Disconnect Notes: Solar Inspector Signature: Date: January 18, 2023 S.Devlin-Cert Electrical Compliance Form OF SOUIyo� Y7(0/5 3 # # TOWN OF SOUTHOLD BUILDING DEPT. `yro631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ . ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O// [ ] RENTAL REMARKS: GrINC& dfaA DATE In-1/1 INSPECTOR �o��OF SOOTyO� -7 4t J 13-O e # # TOWN OF SOUTHOLD BUILDIN DEPT. °`ycaurnr '� 765-1802 - INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] -INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Sat LI IOU-crr ore lo�� mj,5�e_A_ JL eeJ -C-eST 4o _ _ j9AAC1 DATE INSPECT.O.R l �� OF SOUT,yolo - -- # } TOWN OF SOUTHOLD BUILDING DEPT. �o • ,o `ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOW' CAULKING [ ] FRAMING /STRAPPING [ VI FINAL�o l [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL 17A DATE INSPECTOR u, u (i OF SOUTyO� -7(o l`' / # # TOWN OF SOUTHOLD BUILDING TDPT . cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O I [ ] RENTAL REMARKS: / ot/ 10 CAc4 nt->. aou'l n&q DATE `li INSPECTOR Horton, LisaMarie From: Jen Maher <jen.maher@sunrun.com> Sent: Thursday,January 5, 2023 11:50 AM To: Horton, LisaMarie Cc: Damion Carter; Steve Haines; Hillary Zucker Subject: Re: Carrillo #47615 Attachments: Plans_Carrillo,Leivy Rev B_Stamped.pdf Hello again, Here are the photos of the arrays along with the exterior equipment and the planset, which you should have in front of you. Please let me know what Sean says, he can call me if needed. Thank you for your help! 3505 Delmar Dr Laurel Array 1 4 r Arra} 1 } f N r i c MMMEWMIFMW IL I r On Thu, Jan 5, 2023 at 11:40 AM Jen Maher<jen.maher(a)sunrun.com>wrote: Morning, Just so I'm clear- you want the date of the revised plans,that were already submitted, changed to reflect a date after his inspection of 12/6? Please clarify so that I may task our permit team with these revisions. 2 ���. . BUILDING DEPT: December 11,2022 - -- st'r�Mctur��[- ENNE-EI2 Subject: Post-Installation Approval Letter Permit#:47615 Job Number:216R-505CARR; Rev:Al Installation Date:4/21/2022 Client: Leivy Carrillo Address:3505 Delmar Dr, Laurel, NY, 11948 Attn::To'Whom It May Coricerri The purpose of the review was to verify the installation is in conformance with the permitted plan set and that-any potential modifications from those:plans.meet the intent of:the permitted plan set.: .: The PV racking system's attachments have been observed to be.installed in conformance with the permitted plan set.The installation complies with the code provisions listed-below. !:2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,ASCE 7-16,.: :. NDS 2018 •Basic Wind Speed V= 128 mph, Exposure: B •Ground Snow Load=25 psf Paul Zacher,P.E. Professional Engineer T:91'6.9613960.x101 email: paul@pzse.com QF NEfNY �K. ZAcyO� r � 48 W xP�9j365z AR �FESSION FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------ C FOUNDATION (2ND) COD z 0 ROUGH FRAMING& PLUMBING y ` V1 r INSULATION PER N.Y. STATE ENERGY CODE 2 L I 'l, FINAL ADDITIONAL COMMENTS l 1a 22 Q CLQ C ld Y1 rn " - / VAX D ltil � 9 3 , 3 o N Qr o 1 I l%,l L3 — Sjgp4ric. er4— '0 Wz x y x d b H . . ..... Q C19-)2/2- :q. : SUFF94 . . ..... TOWN OF SOUTHOLD-BUILDING DEPARTMENT N Town Hall Annex 54375 Main Road P. O. Box 1179.Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631).765-9502-h tp§:%/www.southoldtownny. og_v. — Dk6 Received APPLICATION FOR BUILDING PERMITif- �: . .'F Office Use Only b. AR � 1 y PERMIT NO. Buildinglnspector: p . M 2022 BUILDING D�P-L Applications and forms must:be filled out in their entirety.'lncomplete TOWN Of .SOUTHOLD applications will riot be accepted. Where the Applicant is not the owner,an Owner's Authorization.form(Page 2).shalEbe completed. Date: 1q. OWNERS)OF PRO ERTY: Name: SCTM#,1000 _ C a. r� la 5 Project Address:. 3 so.S r Phone#: Email: Ie a Mailing Address.: _.J: CONTACT PERSON: Name: b.Mailing Address:. . Phone#: Email::.: - - -- -- DESIGN PROFESSIONAL INFORMATION: Name: - - . -- --._ . _a l l Mailing Address: Phone#: Email: l (p 3 ZPD G v� 2Se q_ . i' CONTRACTOR INFORMATIOW. Name: nin _ /:(/./ J Mailing Address: Phone#: Email: - - 57 - j�l-y _7 1-1 - - -- l.�e rrva, DESCRIPTION'OF'PROPOSED CONSTRUCTION.. []NewStructure [--]Addition .❑Alteration ❑Repair El Estimated Cost of Rroject: her_ _ O�Q ...... . $ Will the lot be re-graded? ❑Yes o Will excess fill be removed from:premises? ❑Yes o. 1. PROPERTY INFORMATION ..... Existing use of property: Intended use of property:. , Zone.or use district in which premises is situated: Are there any covenants a restrictions with respect to ..... this property?:.DYes 2116o IF YES; PROVIDE A COPY: 03"Check Box After Reading: The owner/contractor/design professional.is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town'Code.,APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance,of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,'alterations or for removal or demolition as herein described.The applicant agrees to coi ply with all applicable laws,ordinances,building code,- housing ode;housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessaryinspections.False statements made.herein are P P .. unishable as a[lass A misdemeanor ursuant to Section 210.45 of the New.York State Penal Law. • Application SLib pp miffed By( rint name): S ( Authorized Agent DOwner Signature of Applicant: ( - -- Date: 4 STATE OF NEW.Y.ORK) SS: OUNTY OF - V l�Y __ being duly sworn,,deposes and says that(s)he.is the applicant. (Name of:individual signing contract)above named,:.:.: (S)he is the , —.. ... Ci: 1rC-� '(Contractor,Agent;Corporate Officer,.etc.) of said owner or owners, and is duly authorized:to perform or have performed the said work an:d to make and file this- .application;that:all statements contained in this application are true to the best of his/her knowledge and.belief;and that the work will be performed in the rrianher set forth in theapplication file therewith. Sworn-before me this day of Notary:Public: .JAMES GERARD BRENNAN: No.o16R6376583 PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YORK - Wherethe applicant is not the:'wner bwalified in Nassad County ( PP Uy'CornmIssion Expires 06-18-202. :.. ... I, residing.. t - D do'hereby.authorize to apply on my beh g=h6ld Building Department for approval as described herein. Owner's Signature: Date ..: Print Owner's Name 2 ti _ -4;1 ILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ® 1 �02�To II Annex - 54375 Main Road - PO Box 1179 o • jAR� Southold, New York 11971-0959 41%VBuy o° sovTM+o�-telephone (631) 765-1802 - FAX (631) 765-9502 -rola rogerr(cDsoutholdtownny gov - seand(cr southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: u Electrician's Name: License No.: ,_E_lec.c. email: Lj rmif s rvn CCm Elec. Phone No: -� l5 1 request an email copy of Certificate of Compliance Elec. Address.: 07 7 Gt ve , 0,0 U JOB SITE INFORMATION (All Information Required) Name: ke ►V ( a-rri ll D Address: 35-0S J)eaY V /�(s�relAq /C/ g- Cross Street: Phone No.: Bldg.Permit#: email: e/W eArrj L�2li/- Cr Tax Map District: 1000 Section: /o? 5- Block: Lot: 5- BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): (N Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ O ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑-1`40 Issued On Temp Information: (All information required) Service Size F11 Ph 1—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑underground❑Overhead # Underground Laterals D 1 F12 H Frame D Pole Work done on Service? M Y DN Additional Information: PAYMENT DUE WITH APPLICATION ILDING DEPARTMENT Electrical Inspector TOWN,OF SOUTHOLD. ti To II Annex- 54375 Main Road - PO Box:1179 1202 New York 1197.1-0959 MAR'' Southold, oy�jOl Bui Dj ouFPT eIe hone 631 765=1:802 - FAX (631),765-9502 : . TOIN rogerr _southoldtownny.gov se gov APPLICATION FOR ELECTRICAL. INSPECTION . . ELECTRICIAN INFORMATION-(Au Information Required) Date: Company Name: ' Electrician's Name.:. �3���t�� (.1 rrri7�s run •C LicenseNo.: Elec.:email: Elec. Phone No: -T .. J L I: request an email.copy of Certificate of Compliance-: Elec. Address::. 07 Gt t/2 0 GAP U JOB-SITE (All Information Required) Name:: 2►�/ :_:Address: 35-05 . -beltwew V Z-a(JY&l . Cross Street: -..Phone No.: Bldg'Permit#: email: �- p /a; ". . Block: Lot. i.Tax Ma District: . 1000 :.::Section: BRIEF DESCRIPTION: OF WORK, INCLUDE SQUARE FOOTAGE (Please:Print Clearly): .Ln s 11 a cry: . o Dov cep d sv lcz� pa-0-152 : . . w S L-S wn : . . .. . : .. Square Footage: .. Circle All That Apply: Is job ready for inspection?.: ❑ YES cO ❑Rou h In ❑ Final. Do youneed a Temp Certificate?: YES O Issued On Temp.lnformation: (All information required) : : . . Service Size 1 Ph 3 Ph Size: A :# Meters .. Old Meter#: New.Service Fire Reconnect Flood. Reconnect Service:Reconnect Underground Overhead ❑ ❑ ❑ . .. # Underground Laterals 1 2 . H Frame Pole Work done on Service? MY, N Additional Information: :. PAYMENT DUE WITH_APPLICATION f LSI 26 00e Lot , to 1> 1 � A Q 140..E p, 0 hilli 1 �Ir job 'Y t � 1 t ,00 M • 300 S. $ 24 qF.y" ,r O , NA 4 Nore': .332;,s",�%tom rd�.�v5c SUBq WWON AMP PILEP ON rove OPPICE eue OF TNA"a rm r or NNP'Pax COUN7"Y ON J~Nt, /0 M Ad ANAP #4 04*0. .. :(.(.;: .:5C',?1L�.�a„�t.f�ili`��ttta:f:tt•�.f�Y,,a,,}✓f//'���'yu,+C.am•,..C«!'••.:='-�—;.°�a�"Y:�4'}-.'-i��:.°y<...�>,:.a.�-,4«��>•,�-cw.c;.".._�fi^•-f-.1k^�}r:,'=is.?S_irr^;.„.��.y.,y_il'.fti.'•1ti�Il:;,/'.:�-s..G:,•�s.:,-zu-\r2a'z.�-':'_s`.^�',-:.•f4..r:'.Fv.:�Vi�.cr�:'�:,^ti ier�.2•'„>+••`.'�,•',��rir:'.�.e�fr,t'<:•'.;^'.5c.%+_^.;i^,,a..v;.-..,4,:_-.�a.....'.C'.:..,`”....-'�`�'�'4`'��7,;`.,.N,.,tr'.=:'.'L".lr�•u�.r:�.,•.r::M..,•.C,.i�'a...z',..'.",�r.•",-,-,.:..•[�,<-4e-..a_-U,..lr,_�.`•;;�.^+..;�.�':.a'+'ms.:ti�:Y�-Ls�'L'4:.',�l.�'•/Za,y.r♦<?�,.-fz„`f.Sj_.i:D:t`-arP�]bi_+4..�e;i,s:ry�i-.%-�,.<t.�•a--)c'',jf��,-�a'_�`'..}".49y'sJ(.o�,".�43„!w�r:^-'tiJ�`'7•t.��`,-y��?r`;�4 i,.♦.kuf�:i.�,.ugj�n'i;.r.y..,}eL`��ri�'r}'_;.'in:.'��r,.:..«�..'.<.,�'<._-z•.•.i�, �N:••:.ti,., h-tiir��ss':s.i•-•y.w1.-•`•.'-.�''.�4.l.�) ^..h. fta{ - �1♦ w.-�'c_.d.:��...'.s�-•.(y:y.?:r•�:�-.:".,t.ti.,,w;`e,.`�.•i.`P.`^"-„tti.f�y`�}i,Pt'♦��,5i","'r.P'iri,%y•::�..^7.l' , �.\:• .. .. . �� ` '-_ __'""� - �.=0::..,� J::,:• ;L'.^-�,:w�:.:L"-_-3'cL••a_t:,w',^: 'vv;.x.,'^^,`._i.:•iL?r,,:,�.2'cY :w_5'r:yc:�`.,:t.=,^::^.:."h:::N..>i,`:,;:;•C':.7.c`•.:L:=�: ..::!7:a....it:;r..`..5! ..z"•.•_.�;:, �i�. .r Su o lk Co..un <<r ty DepaYtnzent of.Labor Dcensing: & its" � ; ... Consumer A airs .� �7 VETERANS , MEMORIAL:HINEW YORK HAUPPAUGE, RK11788 t Yn fillj E -DATE S SUED: :. Z 1.0/1/2003. . . No: '33878-IVIE ! a Is t»r 4 �ry1� nrf SUFFOLK COUNTY dc er Elect i ..U` License �4kj -This is to certify that SAMY A MOUNAS 1 �~ doing business as .. . . . . SUNRUN INSTALLATION SERVICES INC: is►;.: ,;> k fN h �t ;�,�,�,� -•r having given satisfactory.evidence.of competency;is hereby licensed as MASTER:ELECTRICIAN in accordance with and subject to-the provisions-of applicable laws rules and regulations of :the:County.of Suffolk,State of New York, Additional Businesses ' L• NOT VALID WITHOUT DEPARTMENTAL SEAL ha�,������:•:�r' ' AND.ACURRENT Mil :``mss I CONSUMER AFFAIRS c• 1 ID CARDG ' ,f;•,;F ',1 Acting Commission er \ t'�;r�F { ... I u ��a t /,y,, Jj .... l:P _ \f ..,_...:..� .55...�.•i✓k,v.V.TY• 1.,..v. v _Tt. .�.. ........ ,��-�. .._...,�-. ......•..... eY�' -:�"•^' � . .d ,N'. .0`. .`b,..,•.• a?. ,.T;^.•.`1.:,.'.`..YS:';C"s'R"v ".-"Y>.'t•.�'S i'�wf:.an"i-.i'L^.`n,:.f'=-`a^$::\� -t'R:4t'.c:.). ^•�`;::i.2 tiCv�s:::a..w'da-ZtY'::d'.L•2.i'.'�:::4'��f. a^�.-b='. .�'," -� -r..;;.�,•' =r-' .°,�-','i `�.' :.fie" �, =�•}.���.r":�'.”"-'3;�-,r ,y .<,•35J, � ,ia,-'-....._.. J. y. "�" •-•._ fry f,. .:�LL'1. J�'^.�: y ixf w D� 7��^ T i .. �RJ'"��.'L'YL'^�s..�_�i F^ �'^���,y>,�.�.y�''.�.....- •;�•..� '` �-•�... �� �- \,,�' [,ftt,' � G..1 %ATL .� ^••7 •1 �^ w� •:.Jt'• ,y1 ,� /� ��l_ ..� �.,(''y 4«�S''y' - }.. yam':Fes" I•r�_}�o _ �<:' tt��_ C ,:,::>..5y << ,;-ti`: i• ,p;. ti•' 7 �'or +•._ , ,::i=� r .�':. �L _sdk',.. �'. •)-.+ w. ,,i,.-r.��': t. ;e: \•��!'Yh`;?'� •/:��> ,r'�HV' .s '.r• -y� j� �:E r.r p� '+y,J;: .1"':• :.7 �.J•�" •G::i� .I� ... ... Li .f, 4•!5,x':' ���: ,r� •h c:• »`a � j t'-"%'''X, - .�\T�t��,9• 3-• ,�� <t..• :z^�- ..�iry o .4.'�'a •�,' as,�`i ^�� _t.: r\L,. ��t� o✓ '`'�n. �e .� c;�'c:�•�"..> �, �?l �... �' -n .. �r -.� ,;'�` /- .- `��1'' -�• -.-est i ��s� :17`x• �...-a•-_.,�((`�`���( './5.:�1� �� � - :�rf.G. � .,',•�•`r�-•;9> .:.a'oy''.'J�,�,�w•�'��'�',��' .,!✓ .;,'fir ,.�a' t ,.•'.;�% <���;_; r^M1 =:;��:.yt, r: 5' `•k�?z � �1��;r�..Dn;-�a� ti�lt41�5 �.c .,r:'^^•a•`����_ .;�,;:• _..'�_•t � rt".rs ;'•:'.�•-..Lv'/1 R*-.,_� a.� 1.✓'°'�. r 1f�,i'�- d',,: _�y.�-..� �=;r-.. •rte?�r� �,:-, � Z:..�. ;.�,.;.t�:., <� _.,�.,,.r. �Gii�a:;.,;,.,rt -�.;:..,_�l,.- �'�. M�, r �;,- -r :t:�->� a <'.;t?a: yS+;_,;c:L,.y rd �k;}., .q+:r:1;1'2` t__:. .,r r +1g,;.• �.s-a�-_" .; TS.�a.��-._e1J�:rir �v.-��.. 1. i� 1f 1. ..r�� 4�'`>�'i' „x''.,q} ��;.a;:�>w..•;,,,a'L%r�+,�er`� iF.�_ 5..; �'1 J•. .: ;.t 1..J r•{Pi`11 of.:?:•` ir:Y Y' �`5;,� f•'.sJ.� :t6�.f7F�.. :.-..7'-«li lf•i�:!'r,- "-il r.l r�l:::: - •�- ty:�f+?:«- ' t:.'^moi-' :>r- :�_�:�� ,,•,v.�t- - •t.,.y. 7:r. i iQ7•y -<Y ;�f. -r". ¢:.,� i ,_t.p-•'^C: 't(„f,,�.�i`'.'d�"-_'ice,%7:1 f1�!:,.'''�-`, .. .;W �*�..���'�' `•.-.,-,w,,''�-'��,, � �;r�y,'.yJ+''`r.;�Y" __,�.• >.`.rc+'' •.?. `�af�•.`"�.`?:.:- .d�/ \:'".e.�'��..�•.:.a.-i. �.,�, t:•- :.e':!I ..� - r ,r _�e',�. Y Y I d e vy sunrun JAN BUILDING DEPT. 177 Cantiague Rock Road TOWN OF SOMOLD.: Westbury.NY 11590 LiPermitsa-sunrun.com 1/12/2023 RE: As'-Built. Plans Permit: 5393 Address: 3505 Delmar 'Dr, Laurel, NY 11948, qw The Following Revisions have been. made.to the.plans: SYSTEM SIZE DECREASED - 918OW to:850OW MODULE COUNT:DECREASED _ 27 to 25 Thank You, 1 JAN Thomas Catterson BUILDING�O . Sunrun Permit Coordinator. , �owNOFsotrtH � 435-919-2666 X7 (015 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:850OW DC,760OW AC •ALL WORK SHALL COMPLY WITH 2020 NYS Code Books w/2018 IRC/IBCAEBC, SOLAR MODULES •MODULES:(25)JA SOLAR:JAM60S10-340/MR ICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE PV-1.0 COVER SHEET MUN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE760OH-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEALMP MAIN PANEL PV-3.0 LAYOUT TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLYSP SUB-PANEL SKIRT SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT& © •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ® CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Q SUNRUN METER ATTIC VENT RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. SM � FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALLINV INVERTER(S) 0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT OF NE(.y Y •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC DISCONNECT(S) K.Z,q�y O•Q Al0 1pSATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. _ w ODC DISCONNECTS) ® FIRE SETBACKS W •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. �...: ��o v�1365�� •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE 'QOFESSIONP� INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT 00825-ME (E) EXISTING +sawaorrs�vE.wKnsw�c Nv+m+ ESS ENERGY STORAGE SYSTEM rxea EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: ,,,,,Q MAG MAGNETIC LEIVYCARRILLO V peg MSP MAIN SERVICE PANEL 3505 DELMAR DR,LAUREL,NY, y° (N) NEW 11948 0 NTS NOT TO SCALE OC ON CENTER TEL.(631)905-7596 - - ;O PRE-FAB PRE-FABRICATED APN:1000-125-00.04-00-005-000 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 216R-505CARR RSD RAPID SHUTDOWN DEVICE •lean.rw iwae,x. TL TRANSFORMERLESS TYP TYPICAL DESIGNER: (415)580-6920 ex3 V VOLTS JACK HASKINS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:B 421/2022 PAGE PV-1.0 CA r ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=3/32"=V-0" SITE PLAN-SCALE=1/64"=V-0" PITCH AZIM AZIM (SOFT) ® AR-01 11' 240' 252° 271.6 DN AR-02 38' 240° 252° 181.1 O;n ROOF ACCESS a 9p (E)DETACHED / Op STRUCTURE g (E)RESIDENCE O� f� Op ROOF PATHWAYS (3'TYP) ROOF ACCESS g \ a (E)RESIDENCE FIRE SETBACKS \\\\/// (E)POOL (N)ARRAY AR-02 (18"TYP) ROOF PATHWAYS (3'TYP) s u n ru n O 00825-ME o O 15p LO EAV,HICltBVLLE W 11851 %KYIE 805.515.Sb) FAX 815.M8.SR3 CUSTOMER RESIDENCE: LEIVY CARRILLO 3505 DELMAR DR,LAUREL,NY, Ff-.m 11948 (N)ARRAY AR-01 SE Ac INV TEL.(631)905-7598 APN:1000-12500-04-00-005-000 PROJECT NUMBER: 218R-505CARR OF NE!-yY DESIGNER: (415)5SM920 64 K Z-40, 0�� JACK HASKINS 9 of SHEET W SITE PLAN �p 91365',Pz cam' REV:B 4/21/2022 ROFESSIONP PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ONWIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 12'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4 2'-1" 4'-0" 1'-8" STAGGERED 128 MPH 3-SEC GUST. RL UNIVERSAL,SPEEDSEAL TRACK ON S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-8" 16" COMP,SEE DETAIL SNR-DC-00436 51-4" 2'-1" 4'-0" 2'-0" STAGGERED 116":2.5"MIN EMBEDMENT STRUCTURAL NOTES: D1-AR-01-SCALE:3/16"=1'-0" INSTALLERS SHALL NOTIFY PITCH:11° 27'-11" —3'-5"— ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES AZIM:240° 1'_11" 1'_11" OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY a,9„ REGION OF ANY ROOF PLANE —5'-0"TYP— EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 9,_11„ ❑ BOUNDARY REGION ONLY AS FOLLOWS: 6'$" ••ALLOWABLE ATTACHMENT SPACING INDICATED ON ❑ PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG 11" INDICATED ON PLANS TO BE {-4 2— 11 2 2 16 9 ,� 1/5TH OF ALLOWABLE ATTACHMENT SPACING ITV-6" 29'-10" INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" PITCH:38° s u n r u n AZIM:240° 00825-ME 16'_11" AB 15CHARL0TTE ,H-NY 11801 PHONE805.5W.- FA%80.5.388.3013 a,�„ CUSTOMER RESIDENCE: LEVY CARRILLO 3505 DELMAR DR,LAUREL,NY, 11948 TEL.(631)905-7598 a'TYP - APN:1000-125-00-04-00-005-000 PROJECT NUMBER: 216R-505CARR -.a- J - ] �7�7777777Z/////77777= OF Z'4 JACK DESIGNER: (415)580-6920 ex3 2'-5" D co yFP�� JACK HASKINS of SHEET 40'-10' + - -w LAYOUT XP'91361 REV:B 4/21/2022 SEE SITE PLAN FOR NORTH ARROW A'QOfESS10NP� PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER M OPSEGLI24232 M ACCOUNT#: UTILITY 9692555978 GRID 1 EXISTING C 200A MAIN BREAKER i EXISTING SOLAREDGE TECHNOLOGIES: 225A (N)LOCKABLE SE760OH-USSN WITH MAIN BLADE TYPE REVENUE GRADE METERING FACILITY PANEL AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 3 2 OR EQUIVALENT 1 JA SOLAR:JAM60S70-340/MR OPTIMIZERS WIRED IN: `Y (1)SERIES OF(10)OPTIMIZERS (1)SERIES OF(15)OPTIMIZERS (N)40A SQUARE D LOAD RATED DC DISCONNECT PV BREAKER AT NOTE:TOTAL PV BACKFEED=40A DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END USED FOR INTERCONNECTION 3R,60A,2P COMPLIANT P370 OF BUSBAR CALCULATIONS 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 1"PVC OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 00825-ME t5 CIMRLOTTE AVE.XMXbuLLE NY 11801 GHG1E 803.310.518] FAC 815.1M.XIlO MODULE CHARACTERISTICS CUSTOMER RESIDENCE: P370 OPTIMIZER CHARACTERISTICS: JA SOLAR:JAM60S10-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC 3505 ELMARCARRILLO OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC 3505 DELMAR DR,LAUREL,NY, MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC 11948 SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC TEL.(631)9057598 AP N:1000-12500-04-00-005-000 SYSTEM CHARACTERISTICS-INVERTERI PROJECT NUMBER: SYSTEM SIZE: 8500 W 216R-505CARR SYSTEM OPEN CIRCUIT VOLTAGE: 15V SYSTEM OPERATING VOLTAGE: 400 VDESIGNER: 415 580-6920 ex3 MAX ALLOWABLE DC VOLTAGE: 480 V JACK HASKINS SYSTEM OPERATING CURRENT: 21.25 A SYSTEM SHORT CIRCUIT CURRENT: 30 A SHEET ELECTRICAL REV:B 4/21/2022 PAGE PV-4.0 WARNING , 1 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE • PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 110.21(8),UNLESS SPECIFIC INSTRUCTIONSARE REQUIREDBY SECTION690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. COMBINER PANELMAXIMUM SYSTEM VOLTAGE: 480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ONLINE AND LOAD DO NOT ADD LOADS MAXIMUM CIRCUIT CURRENT: WORDS,COLORS AND SYMBOLS. 30 '• •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION: •• • THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). CONTROLLER OR DC-TO-DC C• • 15 ADC INVOLVED. LABEL LOCATION: PER CODE(S):NEC 2017:705.12(Bx2x3Xc) •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2017:690.13(B) PER CODE(S):NEC 2017:690.53 �+- WARNING : 77ir POWER SOURCE OUTPUT CONNECTION DDO NOT RELOCATE THISICOVERCURRENT DEVICE LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(8x3) 705.12(Bx2x3)(b) • SOLAR PV SYSTEM BUILDING SUPPLIED BY UTILITY LABEL LOCATION: GRID AND PHOTOVOLTAIC INSTALLED WITHIN T OF RAPID SHUT DOWN SYSTEM SWITCH PER CODE(S):NEC 2017:690.56(CX3),IFC 2012:605.11.1,IFC 2018:1204.5.3 ® sunrun 4 SOLAR PV SYSTEM EQUIPPEDkPV 00825-ME WITH RAPID SHUTDOWN POWER SOURCE CUSTOMER RESIDENCE: L [ LEIVY CARRILLO LABEL LOCATION: 3505 DELMAR DR,LAUREL,NY, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 11948 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3 TURN RAPID SHUTDOWN ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" TEL.(631)9057598 PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), POSITION TO SHUT DOWN ••µms SYSTEM IFC 2012:605.11.1.4 DISCONNECT APN:1000.125.00-04-00-005-000 PV SYSTEM AND REDUCE SHOCK HAZARD IN THE PROJECT NUMBER: ARRAY. LABEL LOCATION: 216R-505CARR • • • • POINT OF INTERCONNECTION OPERATINGMAXIMUM AC CURRENT: _ (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) DESIGNER: (415)5806920 ex3 NOMINALOPERATING VOLTAGE: JACK HASKINS LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2017:690.54 ARE CONNECTED. REV:B 4/21/2022 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 . :a Harvest the Sunshine 340W MBB Half-Cell Module Mono 1 Series Cwntroduction] Assembled with multi�busbar PERC cells,the half-cell configuration of the modules offers the advantages of . power shadingon -energy generation, for •.• Higher output power Lower LCOE Less shading and lower resistive loss Better mechanical loading tolerance I'Superior Warranty Comprehensive Certificates • 12-year product warranty IEC 61215,IEC 61730, UL 61215,UL 61730 • 25-year linear power output warranty ISO 9001:2015 Quality management systems 100% ISO 14001:2015 Environmental management systems ®_ OHSAS 18001:2007 Occupational health and safety manage- ment systems • IEC TS 62941:2016 Terrestrial photovoltaic(PV)modules– Guidelines for increased confidence in PV module design JA Linear Power Warranty ■ Industry Warranty ® `m— N0O .- JASOLAR Specifications subject to technical changes and tests. JA solar reserves the right of final interpretation. r JASOLAR JAM60S10 320-340/MR ® MECHANICAL DIAGRAMS SPECIFICATIONS 996'2 35,1 Cell Mono I Weight 18.7kgt3% ttlittw Dimensions 1689t2mmx996t2mmx35ttmm Enlarge view of I lild 1111111111111 Pill 1111111111111111 mounlinu hole(10'.1) Cable Cross Section Size 4nI (12AWG) uvholes No.of cells 120(6x20) O o O+ IIIIIIIIIII hill III 1 11111111111111 Junction Box IP68,3 diodes ��e�nob. Connector QC4.10 (1000V) no BPI aces QC 4.10-35 (1500V) Label Cable Length Portrait:300mm(+)/400mm(-); Dr.lnlrp hl.. ❑ (Including Connector) Landscape:1000mm(+)/1000mnI 8=aca. Packaging Configuration 30 Per Pallet Remarkcustomized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 TYPE -320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[A 40.60 40.87 41.08 41.32 41.55 Maximum Power Voltage(Vmp)[V] 33.73 33.97 34.24 34.48 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_Isc) +0.044%/°C Temperature Coefficient of Voc(p-Voc) -0.272%/°C Temperature Coefficient of Pmax(y_Pmp) -0.350%/'C STC Irradiance 1000W/ma, cell temperature 25C,AM1.5G Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 Maximum System Voltage 1000V/1500V DC(UL) -320/MR -325/MR -330/MR -335/MR -340/MR Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40°C-+85°C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)[V] 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400PaO12 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 Ib/ft') Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±2°C NOCT Irradiance 800W/m2,ambient temperature 20'C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 1000W/m' -10 1000W/m' 10 -1, 300 60WJ/m' -600W/m' -2SC 6 tfOUJYIm' 250 400W/m, 6 40°C c 6 600W/m, 200 p /m� c 6 70'C y m j o3 150 ? U 4 400W/m' a U 4 00 2 m 50 2 0 0 10 20 30 40 0 0 10 20 30 40 0 0 10 23 30 40 Voltage(V) Voltage(V) Voltage(V) ModulesPremium Cells, Premium solar=@@ Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US ® solar-..= .HD 0 solar•••. 25 .101•••� e _•v_ ® ° o 1 _j r^ 0 Z. eo e s . J o 0 I � e � o 0 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r ' • • z Single Phase Inverter with HD-Wave Technology for North America SE3OOOH-US/ SE38OOH-US / SE5OOOH-US/ SE6OOOH-US/SE76OOH-US/ SE1O000H-US/ SE114OOH-US SE3000H-US SE3800H-US SESOOOH-US I SE6000H US SE7600H US SE10000H-US SE1140OH-US OUTPUT Rated AC Power Output 3000 3800�° 240V SOOU 6000 @ 240V 7600 10000 11400 VA ated..........r Out...................... .....3000..... 3300.(a1208V, 5000�.208V Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,E 208V, , 5000 @-208V 000 AC Output Voltage Min.-Nom.-Max. Vac ..(183 208„-229)........................... ............... ................ ................ ................. ................ . AC Output Voltage Min.-Nom.-Max. Of Va� ..(211,-249_2§4)........................... ................ ................ ................ ................. ................ ................. ................. AC Fre uenc (Nominal) 59.3-60-60.5111 Hz Maximum Continuous Output Current 16 24 A 208V....................................... ................ ................ ................ ................. ................ ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..@240V..................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold 1 A ................................ . ...........................................................Yes.......................................................... ........... Utility Monitoring,Islanding Protection, Country Configurable Thresholds INPUT Maximum DC Power @240V ..... .....4650..... 5900 7750 9300..... 11800 15500 17650..... ... N..... Maximum DC Power @208V 5100 7750 .............................................. ................ ................ ................ ................. ................ ................. ................. ........... Transformer.less,Ungrounded............ ......................................................... Yes .......................................................... ........... Maximum Input Voltage.................. ..........................................................480..... ..Vdc.... .................................................... . Nominal DC Input Voltage 380 400 Vdc ...... .I ........... Maximum Input Current 208V 9 13.5 ................ ................ ................. Maximum Input Current @240V 8.5 10:5 13:5 16S 20 27 30.5 Adc ................ . ..... . ................. ........... Max:Input Short Circuit Current ...... ........................................45 Adc .......................... . ........................................................... . Reverse-PolarityProtection Yes . . ...... ................................................. ......... Ground-Fault Isolation Detection 60OUSensitivity . --------- -------------------- *............ . M .aximum. - inverter ---Efficiency.............. ......99.......I..................................................99:2. %..... CEC Weighted Efficiency 99 % .................................................. ........................................................... ...... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) ............................... ........... Revenue Grade Data,,AN51 C12 20...... Ophona1121.. .. ... ............................................ ........... Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741f UL1741 SA,UL1699B,CSA C22:2,Canadian AFCI according to TILL:M.07 ............. ........... Grid Connection Standards IEEE1547 Rule 21 Rule 14(HI) ........................................... ............................ ... ......... ..... Pl Emissions I FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4':minimum/14-6 AWG............................ 3/4"minimum/144 AWG .. ........... DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3%4"minimum/1"S strings/ AWG RanB?................................ . . 14;6 AWG............ ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 17421. in/mm 3x14.6x7.3/540x370 A 185 .............................................. ................................. ................ .................................. ................................... ........... Weight with Safety Switch.„-........... ...-.--.,-.22/-30...........,1,.25.1/11:4 1 -26.2111:9..,....... 38:8/17:6 Ib/-kg-, Noise <25 I <50 dBA.... .............................................. .................................................................... ................................... CoolinNatural Convection ....,Natural convection .................................. Operating Temperature Ran&e . ............................4 ........ d ..... .'F Protection Rating NEMA 3R(InverterwlthSafetySwltch) ..................... ........... n1 For other regional settings please contact SolarEdge support 121 Revenue grade inverter P/N:SE�H-USOOONNQ Is1 For power tie-rating information refer to:https://www.solamdge.com/sites/default/files/se-temperature-derating-note-na.pdf 141-00 version P/N:SEnni-I-1.15000NN1.14 rrrnm Ro H S 0 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE, OPTIMIZED BY SOLAREDGE • AW .4 JAW ,h .I�t.�+> s ., ` ' ft System designed with r4� All parts fit in a box for easy ` maximum versatility for any logistics arrays including staggered Drop-in features make the - � - install process intuitive and fast _—_---_ Simple design allows system to be installed by single installer U Listed to UL Standard 2703 for on the roof Grounding/Bonding and Fire Classification SnapNrack RL Universal is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the highest spansof any current rail less system. Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments 'R Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing '► row-to-row bonding 0< • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules lt4 • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior. SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. . • • by SnapNrackSolar •unting Solutions. DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins 5flapWack REVISION: Solar Mr inq Solutions PART NUMBER(S): AIM MARKET STREET,29TH FLOOR A SAN FRANCISCO,CA 94105 USA PHONE(415)580-6900•FAX(415)580-6902 242-02155 THE INFORMATION IN THIS D-ING S CONFIDENTIAL AND PROPRIETARY ANY REPRODUCTW,DISCLOSUiE.OR U8E THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONS W OF-RUN SWT1 LLC. 10 5 0 4 3 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins SnapNrock- REVISION: !ar Mniwtinn S PART NUMBER(S): 595 MARKET STREET,29TH FLOOR SAN FRANCISCO,CA 94105 USA PHONE(415)58M9D0 FAX(415)580-6902 242-02155 THEINFORIMTION INTHISOfUWINGISCONFIDENTIALANDPROPRIETARY ANY REPRODUCTION,DISCLOSURE,OR USE THEREOF IS PROMWTED WITHOUT THE WRITTENCONSENTOFSUNRUNSIX HLLC. 1.50 3.41 s 1.50 s L-0- 2.35 1.50 1.55 .66- 2.00 i to 1.24 1.00 SLOT �y 2.63 1.50 ALL DIMENSIONS IN INCHES pa �j t�.V February 14,2022 Astra v.1.62PZE CAT COA Subject:Structural Certification for Proposed Residential Solar Installation. structur- � Job Number:216R-505CARR;Rev Al Client:Leivy Carrillo Address:3505 Delmar Dr,Laurel,NY, 11948 Attn:To Whom It May Concern Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 2020 NYS CODE BOOKS WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V=128 mph,Exposure B •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration GoDCRng Result Landscape 64/25 Staggered 65% Pass AR-01 Portrait 48/20 Staggered 79% Pass Roofing Material Pitch Structure Check Comp Shingle ill Pass Orientation Attachment Spaci ng/C anti lever Configuration GoDCRng Result Landscape 64/25 Staggered 50% Pass AR-02 Portrait 48/24 Staggered 60% Pass Roofing Material Pitch Structure Check Comp Shingle 38• Pass of NEW COQ �K.� cy�o�� Paul Zacher,P.E. Professional Engineer T: 916.961.3960 x101 W email: paul@pzse.com O xP� a,Pz 91365• AR�FESSIC 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE N DESCRIPTION •SYSTEM SIZE:850OW DC,7600W AC •ALL WORK SHALL COMPLY WITH 2020 NYS Code Books w/2018 IRC/IBC/IEBC, SOLAR MODULES •MODULES:(25)JA SOLAR:JAM60Sl0-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE PV-1.0 COVER SHEET INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE760OH-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL PV-3.0 LAYOUT TRACK ON COMP,SEE DETAIL SNR-DC-00436 ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT 8 SKIRT © MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ® CHIMNEY INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER Q ATTIC VENT RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. � FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT OF NE(.y •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT K.ZA0 CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). CO ® T-VENT • �� •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) SATELLITE DISH ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. iDC DC DISCONNECT(S) ® FIRE SETBACKSO °0$136 ?P� OFESSI •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. 16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)). CB IQ COMBINER BOX HARDSCAPE F_--I INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER IAZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT 00825-ME (E) EXISTING 15 LwuuOT EAVE,Mf U5w 11wi ESS ENERGY STORAGE SYSTEM 0E°°3303°' uc xs moxa EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC LEIVY CARRILLO MSP MAIN SERVICE PANEL 3505 DELMAR DR,LAUREL,NY, (N) NEW 11948 Q NTS NOT TO SCALE OC ON CENTER TEL.(631)905-7596 0 PRE-FAB PRE-FABRICATED APN:1000-12500-04-00-005-000 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 216R-505CARR • - RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL DESIGNER: (415)580-6920 ex3 V VOLTS JACK HASKINS O W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:C 12-01-2023 PAGE PV-1.0 SITE PLAN DETAIL•SCALE=3/32"=1'-0" SITE PLAN-SCALE=1/64"=1'-0" ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) ® ® AR-01 11" 240° 252° 271.6 AR-02 38° 240° 252° 181.1 ROOF ACCESS w \ 9p (E)DETACHED / O� STRUCTURE g (E)RESIDENCE O� 9,p ROOF PATHWAYS �P (3'TYP) ROOF ACCESS ? (E)RESIDENCE FIRE SETBACKS �(E).L (N)ARRAY AR-02 (18-TYP) ROOF PATHWAYS (3'TYP) s u n r u n O 00825-ME o O 15 LIWLLO1lE AVE.MCK4NLLE NY t trot VIKVE roS.510.5b] EA%M52M.]Ot3 CUSTOMER RESIDENCE: LEIW CARRILLO 3505 DELMAR DR,LAUREL,NY, SMP 11948 (N)ARRAY AR-01 SE O INV TEL.(631)905-7598 APN:1000-125-00-04-00-005-000 PROJECT NUMBER: of NE w 216R-505CARR Y C co K ZAC, 0� DESIGNER: (415)580.6920 ez3 * 9 't JACK HASKINS lw SHEET ,O v�1361ae2� SITE PLAN ROFFSSIONP� REV:C 12-01-2023 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 12'-0" 16COMP,SEE DETAIL SNR-DC-00436 5'.4" 2'-1' 4--0- V-8' STAGGERED 128 MPH 3-SEC GUST. RL UNIVERSAL,SPEEDSEAL TRACK ON S.S.LAG SCREWS: AR-02 COMP SHINGLE•RLU 2-Story 2X6 RAFTERS 11'-8" 16" COMP,SEE DETAIL SNR-DC-00436 5'.4- 2--l' 4'-0" 2'-0" STAGGERED 16":2.5"MIN EMBEDMENT STRUCTURAL NOTES: D1-AR-01-SCALE:3/16"=1'-0" INSTALLERS SHALL NOTIFY PITCH:11' 2T-11' —3'-5'— ENGINEER OF ANY POTENTIAL AZIM:240° STRUCTURAL ISSUES 1•_11• 1'_11• OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION, 1,`-0• IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY 4,_9" REGION OF ANY ROOF PLANE —5'-4"TY P— EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 9'-11" ❑ BOUNDARY REGION ONLY AS FOLLOWS: ER 63g 8• ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50 ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE }-4'-2'— 11'-2" -2'- 16'-9' ,� ATTACHMENT SPACING 29'-10' V INDICATED ON PLANS D2-AR-02-SCALE:1/8"=V-0" PITCH:38° s u n r u n AZIM:240° 00825-ME 16'-11" Ac ISCWRLOTTE AVE.XICNSNLLE NY IIl01 Rg1E�.�.Sb1 4'-6• CUSTOMER RESIDENCE: LEIVY CARRILLO 3505 DELMAR DR,LAUREL,NY, 11948 TEL.(631)905-7596 4'TYP - APN:1000-12600-04-00-005-000 PROJECT NUMBER: OF NE(yY 216R-505CARR K.ZAO CyF-P DESIGNER: (415)560-6920 ex3 2'_5• O _* JACK HASKINS �I W SHEET 40'-10' O ' 13652"�� LAYOUT OFESStU'- REV:C 12-01-2023 SEE SITE PLAN FOR NORTH AR OW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: M PSEGLIMETER 24232 NO :TOTAL PV BACKFEED=40A UTILITY USE FOR INTERCONNECTION GRID CAL LATIONS SUPPLY SIDE TAP 4 (N)LOCKABLE 1 SOLAREDGE TECHNOLOGIES:EXISTING 200A BLADE TYPE SE760OH-USSN WITH Ac DISCONNECT MAIN BREAKER FUSED REVENUE GRADE METERING T I 7600 WATT INVERTER JUNCTION BOX PV MODULES 3 2 OR EQUIVALENT 1 JA SOLAR:JAM60S10-340/MR EXISTING _ / (25)MODULE225A — S MAIN `- ..i` _— `� �(jj// OPTIMIZERS WIRED IN: FACILITY PANEL 40A FUSES `Y (1)SERIES OF(15)OPTIMIZERS (1)SERIES OF(10)OPTIMIZERS LOADS SQUARE D LOAD RATED DC DISCONNECT D222NRB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A COMPLIANT P370 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1"PVC OR EQU IV. (4)10 AWG THHNrrHWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 4 1"PVC OR EQUIV. (2)6 AWG THHN7THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 00825-ME 5 CNMLLOTIE AVE,H-UE NY i1NI PNONE mS.SW.5b1 E�x eu.me.ma MODULE CHARACTERISTICS p370 OPTIMIZER CHARACTERISTICS: CUSTOMER RESIDENCE: JA SOLAR:JAM60S 1 0-340/MR: 340 W LEIVY CARRILLO OPEN CIRCUIT VOLTAGE: 41.55 V MIN INPUT VOLTAGE: 8 VDC 3505 DELMAR DR,LAUREL,NY, MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC 11948 SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC TEL.(631)905-7598 AP N:1000-12500-04-00-005-000 SYSTEM CHARACTERISTICS-INVERTER 1 PROJECT NUMBER: SYSTEM SIZE: 8500 W 216R-505CARR SYSTEM OPEN CIRCUIT VOLTAGE: 15V SYSTEM OPERATING VOLTAGE: 400 V DESIGNER: (415)580-6920 ex3 MAX ALLOWABLE DC VOLTAGE: 480 V JACK HASKINS SYSTEM OPERATING CURRENT: 21.25 A SYSTEM SHORT CIRCUIT CURRENT: 30 A SHEET ELECTRICAL REV:C 12-01-2023 PAGE PV-4.0 I INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE • PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. CUIT CURRENT: COMBINER PANELMAXIMUM SYSTEM • 480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS _ WORDS,COLORS AND SYMBOLS. 30 •• •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION LABEL LOCATION: • • •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). CONTROLLER OR DC-TO-DC C• D 15 ADC INVOLVED. • LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3&) SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2017:690.13(8) PER CODE(S):NEC 2017:690.53 ! WARNING &WARNING DUALPOWERSUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3) 705.12(151)(2)(3)(b) FOR SOLAR P • 1. . BUILDING SUPPLIED BY UTILITY LABEL LOCATION: GRID AND PHOTOVOLTAIC INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC 2012:805.11.1,IFC 2018:1204.5.3 ® sunrun 4' SOLAR PV SYSTEM EQUIPPED 15C ME 5 HRNLOTTE RYE.NICNSALLE NY 11a11 WITH RAPID SHUTDOWN C F ' .• al . • .• k.PV CUSTOMER RESIDENCE: LEIW CARRILLO LABEL LOCATION: 3505 DELMAR DR,LAUREL,NY, INTERIORAND EXTERIOR DC CONDUIT EVERY 10 FT, 11948 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3TURN RAPID SHUTDOWN ON EVERYJBIPUL BOX CONTAINING OC CIRCUITS. SWITCH TO THE"OFF• TEL.(631)905-7598 PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), POSITION TO SHUT DOWN w. SYSTEM IFC 2012:605.11.1.4 DISCONNECT APN:1000-125-00-04-00-005-000 PV SYSTEM AND REDUCE SHOCK HAZARD IN THEPROJECT NUMBER: ARRAY LABEL TION: 216R-505CARR DISCONNECTPHOTOVOLTAIC AC POINT OF INTERCONNECTION mw. LE (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) DESIGNER: (415)580-6920 ex3 NOMINAL OPERATING AC VOLTAGE: 240 VAC JACK HASKINS LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2017:690.54 ARE CONNECTED. REV:C 12-01-2023 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0 ' -- - Harvest the Sunshine Y - RN � 1 CC • • Mono Higher output power Lower LCOE Less shading and lower resistive loss Better mechanical loading tolerance Superior Warranty Comprehensive Certificates 12-year product warranty IEC 61215,IEC 61730, UL 61215,UL 61730 25-year linear power output warranty ISO 9001:2015 Quality management systems 700% ISO 14001:2015 Environmental management systems OHSAS 18001:2007 Occupational health and safety manage- ment systems IEC TS 62941:2016 Terrestrial photovoltaic(PV)modules— Guidelines for increased confidence in PV module design v JA Linear Power Warranty ■ Industry Warranty I JAS• • www.jasolar.com A Solar reserves the right of final interpretation. ❑� JASOLAR JAM60S10 320-340/MR= MECHANICAL DIAGRAMS SPECIFICATIONS 996iz 36:1 Cell Mono lac Weight 18.7kgt3% Dimensions 1689t2mmx996t2mmx35t1mm Enlarge view of moun8ng hole(0:1) Cable Cross Section Size 4MM2 (12AWG) 1.&V hole No.of cells 120(6x20) O o O Mv:mm Junction Box IP68,3 diodes avau�gna.• Connector OC 4.10 (1000V) b e pace• QC 4.10-35 (1500V) LD" Cable Length Portrait:300mm(+)/400mm(-); 1r.11n,ha.• ❑ (Including Connector) Landscape:1000mm(+)/1000mm(-) e pace Packaging Configuration 30 Per Pallet ELECTRICAL PARAMETERS AT STC TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[V] 40.60 40.87 41.08 41.32 41.55 Maximum Power Voltage(Vmp)M 33.73 33.97 34.24 34.48 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_lsc) +0.044%/°C Temperature Coefficient of Voc(p_Voc) -0.272%/'C Temperature Coefficient of Pmax(y_Pmp) -0.350%/°C STC Irradiance 1000W/m', cell temperature 25'C,AM1.5G Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 Maximum System Voltage 1000V/1500V DC(UL) -320/MR -325/MR -330/MR -335/MR -340/MR Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40'C-+85'C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)[V] 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8,14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 lb/ft') Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±.2C NOCT Irradiance 800W/m',ambient temperature 20'C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 1000wim' t000W/m' 10 10"C 6bWWlm° _ 250 - 600W/m' 8 401C 400W/m' < 551C c 6 bWWlm' 200 - 200W.�m' c 6 70°C t 3 150 U 40 0, U 4 100 2 m 50 2 0 0 10 20 30 40 00 10 20 30 40 0 0 10 2D 30 40 Voltage(V) Voltage(V) Voltage(V) Premium Cells, Premium Modules Version No. 20191220A solar • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/ SE5000H-US/ SE6000H-US/SE760OH-US/ SE1000OH-US/SE1140OH-US o solar-..: _HD ° solar, ,0 ° � a r � e - 0 0 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring IIIIIIIIIII' I L Outdoor and indoor installation w(,,.v e Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r " • • � Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/SE760OH-US/SE1000OH-US/SE1140OH-US _ — SEWWH-US T SE380OH-US I SE5000H-US f SE6000H-US SE760OH-US SE10000H-US SE1140014-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA .............. 3300,O 208V.'._..... .. . . ..... .......... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 760010000 11400 VA 3300.E 208V 5000 208V ............... ... .......... ................ ................ ........... AC Output Voltage Min:Nom:Max. ✓ ✓ Vac X183„208,;2291 ......................... .... . ✓ ✓....... .......✓...... ................ .......✓ ...... ...Vac.... AC Output Voltage Min.-Nom.-Max. I/ ✓ .141.:244.:?.641......................... ............... ................ ............... ................ ............... ................ ............... AC Freyuen.y(Nominal) 59.3-60-60.5(t( Hz ................ ............... ................ . ................ ............... ................ ................ Maximum Continuous Output Current 16 24 - A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A 01240V ............... ................ ............... ................ ............... ................ ................ ........... GFDI Threshold1 A Uti .......ing.,..Islan........ding ....ectio.....n.,.. ........................................................ ....................................................... ........... lity Monitor ..Prot Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W ........... ................ ............... ................ .............. .............. .......... Maximum DC Power(d208V 5100 . 7750 - ................ ................ ...... .. Transformer-less,ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC .. g..Input Volta a ............ ........ 380 400Vdc P . ....... ................ ............... ................ ............... ........ ..... ................ Maximum Input Current 208V 9 13.5 .......... ............... .. ........... ............. Maximum Input Current @240V 8:5...... 10:5 13:5 16:5 20...... ?� 30.5 Adc ..... . Max:Input Short Circuit Current 45 Adc .... ...................................................... ......................................................... .... Reverse Polarity Protection Yes Ground-Fault Isolation Detection 600ka Sensitivity .... . Maximum Inverter Efficiency 99... 99.2 % ... .................................. .............................................. ........... CEC Weighted Efficiency 99 % ....................................................................................................... ........... Nighttime Power Consumption ADDITIONAL FEATURES Su ported Communication Interfaces RS48S,Ethernet,Zi Bee(optional),Cellular(optional) p................_......... ..... . ............I............... ...... g,.....,........ .............................. ........... ReYenYApi:q eData4ANS...... ........ 9099011" ... .„•,••,••,•,., ,,,,, . ,,,,,,,,,,•,,. ,,,..,., .,., •,,,,,,,,,. Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741 UL1741 SA,UL1699Br CSA C22.2,Canadian AFCI according to T.I.L.M-07 ........... Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) EmissionsFCC Part 15 Class B . _. INSTALLATION SPECIFICATIONS AC Out ut Conduit Size/AWG Ran a 3/4"minimum/14-6 AWG 3/4"minimum/14 4 AWG P.................. 6..... ...... ..... ........ .............. ........ ........... . ........... DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings% AWG Ran&? ...........14.-6 AWG........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x /540 x 370 185 in/mm x 18 Wei ht with Safe Switch 221 25.1/11.4 26.2/11.9 38.8/17.6 Ib/ 6 tY....................... ................. . ....... . ......... ...... kg Noise <25 <50 dBA Cooling Natural Convection Natural convection ................. O eratin Tem erature Ran a -13 to+140/-25 to+60(31(-N*.F/-40°C option)l4) F/"C Protection Rating NEMA 3R(Inverter with Safety Switchl lu For other regional settings please contact SolarEdge support (1i Revenue grade inverter P/N:5Ewx xH-USOOONNC2 (3)For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (4)-00 version P/N:SE(ooxH-US0O0NNU4 ROHS 0 Solar'E'Oge Technologies,Inc.All rights reserved.SOLAREDGE, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date: r r Shap rack Solar Mounting Solutions RL • f.. Installing Solar Never Been • Easy � System designed with �� All parts fit in a box for easy maximum versatility for any logistics arrays including staggered Drop-in features make the y - install process intuitive and fast _—_--_—_ Simple design allows system to ���� be installed by single installer U Listed to UL Standard 2703 for on the roof � Grounding/Bonding and Fire Classification Nrack RL Universal . • is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and :L the highest spans of any current rail less system. H Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments � t Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing I► row-to-row bonding • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior. SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • Snap rack- Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated • Rail splices bond rails together, no rail ---- =* jumpers required 0 No drilling of rail or reaching for other tools _ required -` • Class A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy Snaprack- snapnrack.com Solar Mounting Solutions Stainless Bolt with Stainless Steel Bonding Splice — Standard Rail Split-Lock Washer Bolt with Split- Insert 015-09616 Lock Washer Bonding Adjustable End Clamp Top Bonding Splice Mid Clamp Base Bonding Bonding Adjustable ChannelNut End Clamp Bottom �� Bonding Stainless Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock Bonding Adjustable J Bonding Mid Clamp Bonding Standard Washer End Clamp 242-02053 Rall Splice Ground Lug zaz-ozoe7 242-04015 242-02101 12-6 AWG Copper Wire Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave UEC Pull Strap - UEC Wedge Stainless Steel Bolt Z.__J. with Flat Washer IF I IF Universal End Clamp 242-0225 Standoff Clamp Assembly Rubber Serrated Stainless f Channel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree Stainless L Foot Flange Standoff Bolt All Purpose L Foot Mill Finish Standoff Metal Roof Base(11-Hole Mill Finish L Foot Base Assembly Base Shown) Flashing L Foot Base Metal Roof Base Standoff J L L Foot Base with Flashing J with L Foot 242-92057 242-92050 242-02037 SERIES • • TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill finish on select products Material Finish • Silver or black coated hardware Note:Appearance of mill finish products may vary and change over time. Wind Loads 110-190 mph(ASCE 7-10) Snow Loads 0 - 120 psf Array Pitch 0-60 degrees 877-732-2860 www.snapnrack.com contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions.All rights reserved W#*acks l00_Bro&"re2.1 TOPSPEED ROOF ATTACHMENT DETAIL TO WOOD,DECK REVISION: - _ 1 1/28/2022 NEW DETAIL MIA A 5/27/2022 .DC001090 BDP EACH MOUNT HAS 1"OF LEVELING CAPABILITY – —_ REFER TO SNAPNRACK INSTALLATION MANUAL FOR ROOF SURFACE TO BOTTOM OF MODULE _ HARDWARE TORQUE SPECIFICATIONS HEIGHT RANGE:3.5-4.5 IN – –� FOR ATTACHMENT SPECIFICATIONS,SEEN "SNR=DC-30004 TOPSPEED,ATTACHMENT DETAIL,_ MOUNT TO WOOD DECK" MODULE HEIGHT OFF ROOF:_ ROOFING MATERIAL, FOR MOUNT PLACEMENT SPECIFICATIONS,SEE:. 3!x 4'/z IN COMP SHINGLE,TYP. "SNR-DC-30005 TOPSPEED,MOUNT PLACEMENT ON SOLAR PANEL".. BASE HEIGHT UNDER SCREW: MINIMUM DECK THICKNESS' FOR BASIC SYSTEM INFORMATION SEE: 600 IN 7/16"OSB "SNR-DC-30006,TOPSPEED,SYSTEM OVERWEW ON 15/-7/ PLYWOOD COMP" FOR SPECIAL CASE INSTALLATIONS SEE: "SNR-DC-30007 TOPSPEED,SPECIAL CASE INSTALLATION" MIN i'PLYWOOD"OR OSB ROOF DECK MIN 1/4"SCREW PROTRUSION MIN�'PROTURSION OF WOOD SCREW THROUGH DECK TOPSPEED - - MOUNTASSEMBLY ATTACHMENT DETAIL (X4)#14 WOOD SCREWS,S.S. ROOFING MATERIAL, FULLY EMBEDED INTO WOOD DECK COMP SHINGLE,TYP., WOOD ROOF DECKING,TYP. FILL"SPEEDSEAL"CAVITIES WITH APPROPRIATE OVERVIEW ROOF SEALANT TO WATERPROOF ATTACHMENT. SEE INSTALLATION MANUAL FOR DETAILS ON PROPER PLACEMENT ON COURSE Sumun South LLC DESIGNER: M.AFFENTRANGER SG4LE: NTS " DRAWING NUMBER: DESCRIPTION: REV: PH rach- WOM(•'0�°^°°" M(41p—" 2 DRAFTER: M.AFFENTRANGER .: SNR-DC-30004 TOPSPEED,ATTACHMENT DETAIL,MOUNT TO �." DATE: WOOD DECK " A Solar Mounting Solutions """ � � APPROVED BY: B.PETERSON " 5/27/2022 ~ February 14,,2022 _ Astra v.1.62 . .GAT COA Pz Subject:.Structural Certification for Proposed Residential Solar Installation. .. tt_udt E'.b.. - . .. N INE Job.Number:216R-505CARR;.Rev Al Client:Leivy Carrillo: Address:3505 Delmar Dr,Laurel,NY,11948: : Attn:To Whom It May Concern Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural . evaluation of the loading was based.on the site observations and the design criteria listed below. Design Criteria::,:,.:., 2020 2020 NYS CODE BOOKS WITH 2018 IRC/IBC/IEBC;7-16 ASCE&2018 NDS ' Basic Wind Speed V=128 mph;Exposure B . .. ...... .. •Ground SnoW.Load=25 psf .Based:on this evaluation,I certify-that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I:certifythatthe PV module assembly including all attachments supporting it have been reviewed to be in accordance With the manufacturer's specifications. = .. . .... Results Summary(Hardware Check Includes Uplift Check-on Attachments/Fastener,Structure Check Considers Main Structure)'' verni Orientation Attachment Spacing/Cantilever Configuration GoDCRng Result Landscape 64/25 '. Staggered " ':.' Pass AR-01 : Portrait 48/20 Staggered 79% Pass Roofing Material. ...... ..... .Pitch .... . Structure Check . .. . . .. ...... .. Comp Shingle 11° Pass Orientation Attachment Spacing/Cantilever Configuration GoDCRng Result Landscape 64/25 •. Staggered ::' . 50% Pass AR-02 portrait. .. 48.L 24 .....Staggered 60% .. Pass . Roofing Material Pitch Structure Check Comp Shingle. .. ..:..: ...: 38° Pass d WV of oF w . . . E �K• ZAcO... ,P . Paul Zachei'T.E. OCT 25_ .2022 " . CO Professional Engineer '- cc T:916.961.3960 x101 . 1. 8� .. a,i Ii; 9 : . email: paul@pzse.com. Ax P�9T � � L65 .. ...... . TOWN 2: �C � Off':S►fbUTiIiOUI� 'Q�FESSIONP� . 1478 Stone Point Dr:Suite 190,Roseville;:CA,95661 P '(916)961=3960 JASOLAR JAM60S 10 320-340/M R MECHANICAL DIAGRAMS SPECIFICATIONS 99612 3as1 Cell Mono j Weight 18.7kgt3% Dimensions 1689t2mmx996t2mmx35t1mm Enlarge view of mounting hole(0:1) Cable Cross Section Size 4mrrt= (12AWG) Grounding We, 0 pla.a No.of cells 120(6x20) UE O o O umn:.mm Junction Box IP68,3 diodes tmoanuagnalea AA Connector QC 4.10 (1000V) agl_. QC 4.10-35 (1500V) lit Label Cable Length Portrait:300mm(+)/400mm(-); oalnmgroles 11 (IncludingConnector) Landscape:1000mm(+)/1000mrtf(-) a places Packaging Configuration 30 Per Pallet Remark.customized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60SIO TYPE -320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[V) 40.60 40.87 41.08 41.32 41.55 Maximum Power Voltage(Vmp)[V] 33:73 33.97 34.24 34.48 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9:49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W: Temperature Coefficient of Isc(a_Isc) +0.044%/°C Temperature Coefficient of Vo4_Voc)' -0.272%t*C Temperature Coefficient of Pmax(y_Pmp) -0.350%/°C STC [rradiance 1000W/ml, cell temperature 25'C,AM1.5G. Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 Maximum System Voltage 1000V/1500V DC(IJL) TYPE -320/MR -325/MR -330/MR -335/MR -340/MR Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40'C-+85'C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)[V] 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 lb/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 lb/ft') Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 ' NOCT 45t2'C NOCT Irradiance 800W/m',ambient temperature 20'C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 77-M --- - 10 1000WIM2- 300 25°Ca tlUUW/m` 250 _ 55°C6 60UWIm' -..- 200 670`Co 150 U 4 400W/m' a4 tao 2 20D /m 50 2 0 0 10 20 30 40 , D 0 10 20 30 40 0 0 10 27 37 40 Voltage(V) Voltage(V) Voltage(V) ModulesPremium Cells, Premium 1 t' solar=ee Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US / SE5000H-US/ SE6000H-US/SE760OH-US/ SE10000H-US/ SE1140OH-US SE3000H-US SE380OH-US SE5000H-US I SE6000H-11S SE7600H US SE30000H-US I SE11400H-US OUTPUT Rated AC Power Output 3000 3800-@240V 5000 6000 @ 240V 7600 10000 11400 VA .............................................. ................ .3300,(n,208V. ................ .5000..e°.208V. ................ ................. ................. ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,�a 208V. ................ .SOOO.. .208V ................ ................. ........... AC Output Voltage Min:Nom.-Max. ✓ ✓ - - - Vac ..(183,-208. 229)........................... ............... . ............... ................ ................. ................ ................. ................. ........... AC Output Voltage Min.-Nom.-Max. ✓ ✓ �/ / ✓ Vac AC Frequency(Nominal).................. ................ 59.3.-..6.0.-.6.0..5.h).............i. ........ ........... (211-240.:264........................... ..... .......... ................ ................ ................. .. H?..... Maximum Continuous Output Current 16 24 A .208V....................................... ................ .....I.......... .......:........ .....I........... ..........I..... ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A .0°.240V..................................... ................ .I.............. ................ ................. ................ ................. ................. ........... GFDI Threshold1 ................ ....°..... ....................................... ............................................................ ............................................ Utility Monitoring,Islanding Protection, Yes CountryConfi urable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Nn ..208V.............. ................ .....5100.,.,. .... 7750 ........ ................. ................. ........... Transformer-less,Ungrounded Yes ............................................................. ........... Maximum Input Voltage Nominal DClnputVolta�e 380 ......... ..... 400 .... , Vdc ................ ............ Maximum Input Current 13.5 rent @240V 8.5 105 Maximum Input Cur13;5 16S 20 27 30 5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarit Protection Yes Ground-Fault isolation Detection 600ka5ensitivity ..... .. .... ..... ..... .......................... ................ Maximum Inverter Efficiency 99...... .............................................. 99 2 .0..... ............................................ .......... .. ....... . .... ............ .CFC Weighted Efficiency.................. ...........................................................99........................................................... ....1�..... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade,Data,,AN51C12;20,,,- „ .. Oppon. . ...... ......... .. ......, ........................ ........... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety „ UL1741,UL1741 SA,UL16998,CSA 022:2,Canadian AFCI according.to T.I.L,M-07 ..................... ........... Grid Connection Standards ... .....................IEEE1547 Rule 21 Rule 14(HI) .................................. ........... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS, AC Output Conduit Size/AWG Range 3/4"minimu...m.../14-6.....AWG..................... 3/4"minimum/14-4 AWG ........ . .... DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWG Rang?............................... .......... . . 14-6 AWG............ ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm 21.3 x 14.6 x 7.3/540 x 370 x 185 .............................................. ................................. ................ ............6.2/................ ................................... ........... Weight with Safety Switch................ .............22/,10.............I..25.1/11:4..I...........26.2/11:9........... ....... .38....17:6............ .Ib/.. Noise Cooling ..... .............. Natural Convection Natural.conv.ecn ..... .... ....tio................... ........... OperatinpTemperatureRange ........_ ........ „-13 to+140/:25to+60 (40F/;40Coption)1°i ... „°F/'C ProtectionRatin NEMA3R(InverterwithSafetySwltch) ....... ........ ........ ... ........... In For other regional settings please contact SolarEdge support (2)Revenue grade inverter P/N:5E� uH-US000NNC2 (3)For power de-rating information refer to:https.,//v .solaredge.mm/sites/default/files/se-temperature-derating-note-na.pdf i°i-40 version P/N:SEa H-USOOONNU4 0 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE.the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks W301arEdge Technologies.Inc,Ali other trademarks mentioned herein are trademairks,of their respective owners�Date:07/2018/VOI/ENG NAM.Sut�iect to change without notice. i- ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:25 PSF Span Spacing WIND SPEED: RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" T-8" STAGGERED 128 MPH 3-SEC GUST. AR-01 COMP SHINGLE-RLU 2-Story2X6 RAFTERS 12'-0' 16" COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED N6":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 111-81, 16" COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:3116"=V-0" ENGINEER OF ANY POTENTIAL PITCH:11° 2T-11" —3-5 STRUCTURAL ISSUES AZIM:240° �1'-11" �'-11" OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. IF ARRAY(EXCLUDING SKIRT) 1'6" IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE 4,4„ EDGES(EXCEPT VALLEYS), —5'4"TYP— THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS. FOLLOWS: 6,$„ ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG 11" INDICATED ON PLANS TO BE I I 1/5TH OF ALLOWABLE _2'_ 16'-9" Ti' ATTACHMENT SPACING INDICATED ON PLANS 29'-1 0' D2-AR-02-SCALE:1/8"=1'-0" s u n r u n PITCH:38° AZIM:240° 00825-ME AB 16'-11" 15 CHARLOTIEAVE,HK](SV4LE NY 11801 FHONE¢055W 5a01 FA%Bl5]692023 CUSTOMER RESIDENCE: 4'-6" LEIVY CARRILLO 3505 DELMAR DR,LAUREL,NY, 11948 TEL.(631)905-7598 - 4'TYP - APN:1080-125-00-04-00-005-000 PROJECT NUMBER: 216R-505CARR 777 OF NE!-yY DESIGNER: ro (415)58MS20 ex3 D K.ZgOy��OP� JACK HASKINS 2'-5" 11 SHEET 40'-10" —n. I, A Jab w LAYOUT a �13fi6 � REV:B 4/21/2022 SEE SITE PLAN FOR NORTH ARROW AROFESSICA PAGE PV-3.0 . . ... . .. . .... S unfu n* = .. .. . ...... . ... . . . ® 2.QVIS R6ck-,-Road . Westbury IVY 11-560 OCT 5 2022 LiPermits(bsuiiruh-cl-t M. . - . TOWN PF SOUTROLD m. Perrr;it=: LEI V'Y fl,t4 3-5505- D:ELM-A 3 . ft hilo.t7r : rrrs -ons:`hn rd_ oh `: tri ; . ..... . .. . ..... . . Tt+v. pa r .r. : rhive, - een.::revi_ .ed. tw Thi- r�.k .y, u ► :: . ... . Desiree-�le_v'i'ns_. t �%rrti: p_ ri:t: :odMatr . . L4 I cots' C a r FCOMP, OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION IZE:850OW DC,760OW AC ALL WORK SHALL COMPLY WITH 2020 NYS Code Books w/2018 IRC/IBC/IEBC, SOLAR MODULES(25j JA SOLAR:JAM60S10-340lMR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCEPV-1.0 COVER SHEET .(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL PV-3.0 LAYOUT OMP,SEE DETAIL SNR-DC-00436 ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT A •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ® CHIMNEY INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER Q ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. = FLUSH ATTIC VENT SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. 0 PVC PIPE VENT OF NEIy •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALLINV INVERTER(S) ® METAL PIPE VENT K.Z-4 0,p CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). — ® T-VENT t ��t 5 �' K CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) .r X48 1p SATELLITE DISH q •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. �Pol. •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. 0 DC DISCONNECT(S) FO FIRE SETBACKS AQO�SSIONP\ •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX � HARDSCAPE INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n ru n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM VICINITY MAP COMP COIMUTH POSITION s DC DIRECT CURRENT 00825-ME (E) EXISTING sscHnuone eve,wcKsviue Nr 11 ESS ENERGY STORAGE SYSTEM Fq,°—ei t EXT EXTERIOR r INT INTERIOR CUSTOMER RESIDENCE: � MAG MAGNETIC LEIVY CARRILLO cissn'"tnic3z s6' % MSP MAIN SERVICE PANEL 3505 DELMAR DR,LAUREL,NY, (N) NEW 11948 S NTS NOT TO SCALE jVI;_ _%s t" OC ON CENTER TEL. 631 905-7598 •r.uxs cax PRE-FAB PRE-FABRICATED APN:1000-125-Oo-04-oo-o0S000 PSF POUNDS PER SQUARE FOOT a PROJECT NUMBER: PV PHOTOVOLTAIC ; s s:csQez3 a JAN 3�� RSD RAPID SHUTDOWN DEVICE 216R-505CARR �ED"j {� 3��� 7� TL TRANSFORMERLESS 415 580-6920 ex3 TYP TYPICAL DESIGNER: ( ) a" V VOLTS JACK HASKINS cr BUILDINGW". W WATTS SHEET t { COVER SHEET TOWNOFSOLTM D REV NAME DATE COMMENTS REV:C 12-01-2023 PAGE PV-1.0 4 SITE PLAN DETAIL-SCALE=3132"=1'-0" ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1164"=1'-0" PITCH AZIM AZIM (SQFT) ® ® AR-01 110 240° 252° 271.6 AR-02 38° 240° 252° 181.1 O� ROOF ACCESS (E)DETACHED STRUCTURE (E)RESIDENCE O� vp Op ROOF PATHWAYS (3 TYP) ROOF ACCESS / e (E)RESIDENCE (N)ARRAY AR-02 FIRE SETBACKS (E)POOL (18-TYP) ROOF PATHWAYS (3'TYP) s u n r u n O 00825-ME O O 15 CHARLOTTE AVE.HICKSVILLE NV 11801 PHONE B05.SOOS481 FAX B0516S1013 CUSTOMER RESIDENCE: LEIVY CARRILLO 3505 DELMAR DR,LAUREL,NY, SMP 11948 (N)ARRAY AR-01 SE O INV TEL.(631)905-7598 APN:1000-125-00-04-00-005-000 PROJECT NUMBER: OF NE 1y 216R-505CARR A y �K-ZA CDESIGNER: (415)580-6920 ex3 + 5 * JACK HASKINS 4 4$ SHEET SITE PLAN Op �91365� RQFESSIONP REV:C 12-01-2023 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 12'-0" 16" COMP,SEE DETAIL SNR-DC-00436 5--4- 2'-1" 4--0- 11-81. STAGGERED 128 MPH 3-SEC GUST. AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11' RL UNIVERSAL,SPEEDSEAL TRACK ON S.S.LAG SCREWS:-8" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4- 2--1- 4--0- Z-011 STAGGERED /16":2.5"MIN EMBEDMENT STRUCTURAL NOTES: D7-AR-01-SCALE:3/16"=1'-0" INSTALLERS SHALL NOTIFY PITCH:11° 27'-11" .'-3!-5'—,. ENGINEER OF ANY POTENTIAL AZIM:240° STRUCTURAL ISSUES 1'-11" rr1'-11" OBSERVED PRIOR TO PROCEEDING W/ 1 INSTALLATION. ZZZ V-6- IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY 4,-9„ REGION OF ANY ROOF PLANE —6-4TYP— I EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 9'_11" ❑ BOUNDARY REGION ONLY AS FOLLOWS: 6'-8" ••ALLOWABLE ATTACHMENT SPACING INDICATED ON ❑ PLANS TO BE REDUCED BY 50 ••ALLOWABLE OVERHANG 11" INDICATED ON PLANS TO BE I I 115TH OF ALLOWABLE 16'-9" T} ATTACHMENT SPACING 29'-10" L1,_6„ INDICATED ON PLANS D - -SCALE:118"=7'-0" s u n r u n PITCH:H:38 38° AZIM:240° 00825-ME 16'-11" 15 CHARLOTTE AVE,HIC-ILLE W 11801 PHONE 005510518] FA%BG536810]3 4'I6" , CUSTOMER RESIDENCE: LEIVY CARRILLO 3505 DELMAR DR,LAUREL,NY, 11946 4'TYP - TEL.(631)905-7598 11'-2" 13 B, APN:1000-125-00-04-00-005-000 PROJECT NUMBER: OF NEGyr 216R-505CARR �K.Z.4 0 zzzL co yF � DESIGNER: (415)580-6920 ex3 2'-5" 0 5 r, JACK HASKINS I a l 48 W }-3'- 16'-7" 40'-10" O o00 'P2 a� SHEET LAYOUT 91365- F. AROFESSIDNP� REV:C 12-01-2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: M PSEGLI 24232 NO :TOTAL PV BACKFEED=40A UTILITY USE FOR INTERCONNECTION GRID CAL LATIONS SUPPLY SIDE TAP 4 (N)LOCKABLE SOLAREDGE TECHNOLOGIES: C EXISTING 200A BLADE TYPE SE760OH-USSN WITH MAIN BREAKER FUSED AC Ac } DISCONNECT REVENUE GRADE METERING I 7600 WATT INVERTER JUNCTION BOX PV MODULES EXISTING 3 2 OR EQUIVALENT 1 JA SOLAR:JAM60S10-340/MR _ / (25)MODULES 225AMAIN `� ../'` �� + // (25) OPTIMIZERS WIRED IN: FACILITY PANEL 40A FUSES `Y (1)SERIES OF(10)OPTIMIZERS LOADS (1)SERIES OF(15)OPTIMIZERS 6Ro�,No SQUARE D LOAD RATED DC DISCONNECT D222NRB WITH AFC],RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A COMPLIANT P370 1201240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 11 (2 W H N- 1 10 T H 8A TH W 4 1"PVC OR EQU IV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHNIFHWN-2 (1)8 AWG THHNlFHWN-2 00825-ME 15 CHARLOTTE AVE.--LLE NV 11801 PHONE 8055/05097 FAX 905.2682073 MODULE CHARACTERISTICS CUSTOMER RESIDENCE: P370 OPTIMIZER CHARACTERISTICS: JA SOLAR:JAM60S10-340/MR: 340 W LEIW CARRILLO 6 OPEN CIRCUIT VOLTAGE: 41.55 V MIN INPUT VOLTAGE: VDC 3505 DELMAR DR,LAUREL,NY, MAX POWER VOLTAGE: 34.73 V MAX INPUT VOLTAGE: 60 VDC 11948 SHORT CIRCUIT CURRENT: 10.46 A MAX INPUT ITC: 11 ADC MAX OUTPUT CURRENT: 15 ADC TEL.(631)905-7598 APN:1000-125-00-04-00-005-000 SYSTEM CHARACTERISTICS-INVERTER 1 PROJECT NUMBER: SYSTEM SIZE: 8500 W 216R-505CARR SYSTEM OPEN CIRCUIT VOLTAGE: 15V SYSTEM OPERATING VOLTAGE: 400 V DESIGNER: (415)580-6920 ex3 MAX ALLOWABLE DC VOLTAGE: 480 V JACK HASKINS SYSTEM OPERATING CURRENT: 21.25 A SYSTEM SHORT CIRCUIT CURRENT: 30 A SHEET ELECTRICAL REV:C 12-01-2023 PAGE PV-4.0 YYARNON�• INVERTERI NOTES AND SPECIFICATIONS: &WARN 1N G �. PHOT• S , . , •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM NNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR COMBINER PANELIF REQUESTED BYTHE LOCALAHJ.MAXIMUM • Gll� 480 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS WORDS,COLORS AND SYMBOLS. 30 • •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: •OUTPUT CURRENTOF METHOD AND SHALL NOT BE HAND WRITTEN. PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). • •• -••• •• • • 15 ! INVOLVED. LABEL LOCATION: PER CODE(S):NEC 2017:705.12(B)(2)(3)(c) •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),ACIDC DISCONNECT(S), LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2017:690.13(B) PER CODE(S):NEC 2017:690.53 ;/�� &WARNING WARNING DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTON SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):NEC 2017: PER CODE(S):NEC 2017:705.12(B)(3) 705.12(B)(2)(3)(b) Q® •O e. PV SITEM BUILDING SUPPLIED BY UTILITY LABEL LOCATION: GRID AND PHOTOVOLTAIC INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018:1204.5.3 ® sunrun 4" MT] SOLAR PV SYSTEM EQUIPPED a 00825-ME WITH RAPID SH Ac ® _ 8 CUSTOMER RESIDENCE: LEIVY CARRILLO LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 1194 DELMAR DR,LAUREL,NY, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3„ TURN RAPID SHUTDOWN 11946 ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" BOwPp1C TEL. 631)905-7598 PER CODE(S):NEC 2017:690.31(G)(3),690.31(G)(4), POSITION TO SHUT DOWN PV SYSTEM IFC 2012:605.11.1.4 PV SYSTEM AND REDUCE DISCONNECT APN:1000-125-00-04-00-005-000 SHOCK HAZARD IN THE PROJECT NUMBER: ARRAY. LABEL TION: 216R-505CARR '-PH0TOV0LTAIC,ACDISCONNECTPOINT OF INTERCONNECTION ®- (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) DESIGNER: (415)580-6920 ex3 • •- - .LT • JACK HASKINS LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2017:690.54 ARE CONNECTED. REV:C 12-07-2023 PER CODE(S):NEC 2017:690.56(C)(1)(a) PAGE PV-5.0