Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
48368-Z
�p�OSHFF�CKcpGy� Town of Southold 1/6/2023 o - P.O.Box 1179 W 53095 Main Rd oo� �ap� r4� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43745 Date: 1/6/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 765 Madison St, Greenport SCTM#: 473889 Sec/Block/Lot: 41.-1-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/19/2022 pursuant to which Building Permit No. 48368 dated 10/4/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing single family dwelling as applied for. The certificate is issued to Charters,Matthew&Kaitlin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48368 12/6/2022 PLUMBERS CERTIFICATION DATED thor e Si nature TOWN OF SOUTHOLD aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY y � BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48368 Date: 10/4/2022 Permission is hereby granted to: Charters, Matthew 40 Madison St Greenport, NY 11944 To: Install roof mounted solar panels to an existing single family dwelling as applied for. At premises located at: 765 Madison St, Greenport SCTM #473889 Sec/Block/Lot# 41.-1-2 Pursuant to application dated 8/22/2022 and approved by the Building Inspector. To expire on 4/4/2024. Fees: SOLAR PANELS $50.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector pF SO(/j�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a-town.southold.ny.us Southold,NY 11971-0959 COWNs�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Matthew Charters Address: 765 Madison St AKA 40 city,Greenport st: NY zip: 11944 Building Permit#: 48368 Section: 41 Block: 1 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: SUNation Solar License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12.96kW Roof Mounted PV Solar Energy System w/ (32) REC 405W Modules, IQ4 Combiner AC Disconnect Notes: Solar Inspector Signature: ✓ Date: December 6, 2022 S.Devlin-Cert Electrical Compliance Form OE SOGIyo� $ 3 (06 C " I alid-OA �-� AV,7(�e f # TOWN OF SOUTHOLD BUILDING DEPT. �ycoum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: ��1,0� Of k., r DATE IZ 7/ INSPECTOR s ` SOUTyOIo # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULZi: /CA LKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE ARKS: 7 DATE j INSPECTOR Fishier En:grieern�g �Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 - Phone: (631)786-4419 -j(o 5 Ta is o n November 15, 2022 Town of Southold Post Installation Certification Subject: Engineer Statement for Solar Roof Installation DEC 0 5 2Q22 Charters Residence-40 Madison Street, Greenport LD Permit No.:463688- 9 T3 '71� BUILDING DEPT , Instal l Date: 11/11/2022 7OWN OF SOl1Tl-?DLD Inspection Date: 11/15/2022 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services, P.C. to be in compliance with the minimum requirements of the Town,the 2020 Residential Code of New York State,2018 International Residential Code(2018 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017,and the provisions of ASCE 7-16. Sincerely, �r William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) H ------------------------------------ C FOUNDATION (2ND) z 0 H ROUGH FRAMING& PLUMBING rrnn � V, r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS O g z �rn � k H x H x d r� b H o�°SufF���000 TOWN OF SOUTHOLD—BUILDING DEPARTMENT y y= Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov 1� 9• Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. a c/ V Building Inspector: AUG 19 2022 Applications and forms must be filled out in their'entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. ,Owner's Authorization form(Page 2)shall.be completed. TOWN OF SOUTHOLD Date: OWNER(S)OF PROPERTY: Name:Matthew Charters SCTM#1000-41-1-2 - - - _ . . Project Addresi 4qyadison Street, Greenport, NY 11944 Phone#:631-873-7315 F��charters90@gmail.com Mailing Address:40 Madison Street, Greenport, NY 11944 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems.. Mailing Address: 171 Remington Blvd„_Ronkonkoma,NY 11779 Phone#: 631-750-9454 - .TEmail: ermittin sunation.com DESIGN PROFESSIONAL INFORMATION: Name:William Fisher Mailing Address:509 Sayville Blvd, Sayville, NY 11782 Phone#:631-786-44.19.. Email:bill@fisher-ny..com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd., Ronkonkoma,, NY 11779 Phone#: 631-750-9454 Email:perm ittin sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ (A. I ��•bv Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 0-Check Box After Reading: The owner/contractor/design piofessional.is responsible for"all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors'on premises and in building(s)for necessary inspections.False statements made herein are punishable as,a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): Scott askin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 6 day of } "tid J+ ,20 a La- Notary Public TAMMY LEA Notary Public.State of New York PROPERTY OWNER AUTHORIZATION Regrstration No.OILE6410842 Qualified in Suffolk County (Where the applicant is not the owner) Commission Expires November 2,201\ Matthew Charters residing at 40 Madison Street Greenport do hereby authorize Scott Maskin to apply on my behalf to the Tow of Southold B it ing Department for approval as described herein. �a wn s S atLI a ate Matthew Charters Print Owner's Name 2 OS�F�pt�.c~ BUILDING DEPARTMENT-Electrical Inspector �Gy TOWN OF SOUTHOLD f�o � '� Town Hall Annex - 54375 Main Road - PO Box 1179 +# �' � Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov-w sea nd(&-southoldtownnyrgov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permitting@sunation.com Address:_ 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Matthew Charters Address: 40 adison Street Greenport, NY 11944 Cross Street: aK -. -725 Madi-c;on Phone No.: 631-873-7315 Bldg.Permit `6 31A email: mcharters90@gmail.com Tax Map District: 1000 Section: 41 Block: 1 Lot: 2 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# . New Service- Fire Reconnect- Flood Reconnect-Service Reconnected-Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals NYS 1 F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.Com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 753118816 0• '0 5 GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 mm SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBERPOLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIRECTOR,ISURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 l�H�ill�III00000001100000994033041Hi Form WC-CERT-NOPRINf Version 3(08/29/2019)[WC Policy-216067021 U-26.3 64 [00000000000099403304][0001-000021606702][#*Z][15782-06][CertNoP-CERT 1][01-00001] ® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) A�O 2/11/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: The Horton Group PHONE FAX 10320 Orland Parkway NNE ExtI:708-845-3000 ac Ne: Orland Park IL 60467 ADDRESS: certificates@thehortongroup.com INSURERS AFFORDING COVERAGE NAIC# INSURERA:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER B:The Continental Insurance Company 35289 SUNation Solar Systems, Inc. 171 Remington Blvd INSURER C:Axis Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURER D:Travelers Property&Casualty Company of America 25674 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLTYPE OF INSURANCE JU&SUER POLICY NUMBER MM/DDI EFF MPOMIOIEXP WVD OD LIMITS LTR A GENERAL LIABILITY Y Y MKLVIENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE $1,000,000 DAMAGE TO RENTED X COMMERCIAL GENERAL LIABILITY PREMISES Ea occurrence $300,000 CLAIMS-MADE F—I OCCUR MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COM P/OPAGG $2,000,000 POLICYFX]PRO- LOC $ JFCT F-]B AUTOMOBILE LIABILITY Y Y 7018308202 2/112022 2/11/2023 COMBINED SINGLE LIMIT Ea accident $1,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS NUTOS ON-OWNED PROPERTY DAMAGE $ HIREDAUTOS AUTOS [(Peracddent C UMBRELLA LIABX OCCUR Y Y P-001-000795195.01 21112022 2/11/2023 EACH OCCURRENCE $3,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $3,000,000 DED I I RETENTION$ I $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE❑ N/A E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-030-2T010874-TIL-22 2/112022 2/11/2023 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more apace is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ^—y ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD 1 Suffolk County Dept.of Labor,Licensing&Consumer Affairs , t HOME IMPROVEMENT LICENSE Name � SCOTT A MASKIN x IAl�p Business Name • s cert'rfles that the firer is duly licensed SUNATION SOLAR SYSTEMS INC be County of sut=olk License Number:H-44104 , Rosalie Drago Issued: 03/06!2008 t Commissioner Expires: 3/1/2024 t ' ' 4 9 t. G� 7 I' I 6 b r f � t I r 1 �f y r+� 7 L *" Suffolk County Dept of Labor,Licensing$Consumer Affairs rl MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN Business Name This certifies that the SUNATION SOLAR SYSTEMS INC bearer is duly licensed by the County of Suffolk License Number:ME-33412 � Rosalie Drago Issued: 06124/2003 Commissioner Expires: 06101/2023 i i I r 1� i M� r I r I I e Suffolk County Dept.of Labor,Licensing$Consumer Affairs HOME IMPROVEMENT LICENSE :`.r. Name { SCOTT A MASKIN Business Name • `` certifies that the firer is duty licensed SUNATION SOLAR SYSTEMS INC he County of sufol'K License Number:H-44104 Rosalie Drago Issued: 03/06/2008 Commissioner Expires: 3/1/2024 • f i i; i i t i I Suffolk County Dept.of Labor,Licensing$Consumer Affairs f �!. MASTER ELECTRICAL LICENSE Name 'r SCOTT A MASKIN • Business Name # This certifies that the hearer is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk I License Number:ME-33412 Rosalie Drago Issued: 06/2412003 j Commissioner Expires: 06/01/2023 1 t r 6' d i •3� a i i� t� ®-UTILITY METER PLAN KEY NOa(J J ®'SERVICE DISCONNECT P RESIDENTIAL -0 COVER SHEET lT SUPPLY SIDE CONNECTION At-1 PARTIAL ROOF PLAN iAUTOMAncTRANS1EIISWITCH PHOTOVOLTAIC S A1-4 ROOF ACCESS PLAN M,-GAS METER S11-1 STRUCTURE ®-MAINSERVICEPANEL El-1 ONE-LINE DIAGRAM ®-SUB PANEL SUNATION SOLAR SYSTEMS S 4355 � -WIRELESS ROUTER (14)PROPOSED PV MODULES 171 REMINGTON BOULEVARD INSTALLER R INVERTER E2-1 PV LABELS RONKONKOMA, NEW YORK 11779 NUMBER B- -- - G1-1 PV PHOTOS Q-ENPHASE 10 COMBINER Charters Residence Q-PANEL PHOTOVOLTAIC ❑- 40 Madison Street, Greenport, NY 11944 ELECTRIC VEHICLE CHARGER ®-ENPHASE ENVOY ROOF Drawn By: SELECT- 08/12/2022 -SENSE CONSUMPTION MONITOR ACCESS 36" — IE -AC DISCONNECT Q FD� � �� / (T -TESLA GATEWAY V Dj -TESLAPOWERWALL ()FENPHASE 10 SYSTEM CONTROLLER m `�.F•AccEss �P���° sh `� FISHER ENGINEERING SERVICES, P.C. -EN PHASE IO LOAD CONTROLLERAlAAAAAA 18"-VENTILATION ROOF ;3 I �� -7- 509 Sayville Boulevard A U G 1 9 2022 W-ENPHASE101oBATTERY 18"-VENTILATION w> Sayville, New York, 11782 ®-ENPHASE103BATTERY 18"-VENTILATION �y " ., 4Licensee No. 074659 qH-GENERATION PANEL 18"-VENTILATION ' ^",�/�E59 ?� (631)-786-4419 18"-VENTILATION Bill @ Fisher-NY.com BUILDING DEPT. M-BACKED UP LOADS CENTER I VVVVVT TOWN OF SOUT 101,D -VENT PIPE -EXTERIOR LOCATION 1STFLDORLOCATION Building Review Note BASEMENT LOCATION ROOF Town building examiner has received the enclosed document for minimum acceptable -GARAGE LOCAWN ACCESSI plan submittal requirements of the town as specified in the building and/or Residential 36" '�� Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York vivvvvv-- (B) State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM interpreted as an attestation that,to the best of the licensee's belief and information AC the work in this document is: Module Type/Qty: (32)REC405 Pure Black MSP DSC (6)PROP SED PV MODULES- Accurate ATS Conforms with governing codes applicable at the time of submission _SS Module Dimension: 71.69"x 40"x 1.18" U Conforms with reasonable standards of practice and with view to the safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 45 lbs/2.3 PSF (EXT) licensee. Micro Inverter: (32)Enphase IQ8PLUS-72-2-US (12)PROPOSED PV MODULES APPROVED AS NOTED ✓ I,, Structural Statement System DC Rating: 12.96 kW FRONT OF HOUSE - FACIR.a STREET OR DRIVEWAY (6 • The existing structure is adequate to support the new loads imposed by the 0-'-I- Estimated AC Production: 11,118 kWh/yr DAIF_�00'00 BY IB.P. # photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Production Source: Aurora FE NOTIFY BUILDING DEPARTMENT AT PV Notes 765-1802 8 AM TO 4 PM FOR THE 1. This PV system has been designed to meet all current and applicable fire FOLLOWING INSPECTIONS: prevention setback pathways per 2020 NYS Residential Code. Proper ground 1. FOUNDATION -TWO REQUIRED clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code FOR POURED CONCRETE reference and exception for any codes is depicted on the PV-1 plate of this 2. ROUGH FRAMING.PLUMBING, drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the STRAPPING. ELECTRICAL&CAULKING solar equipment. 3. INSULATION 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 4. FINAL-CONSTRUCTION &ELECTRICAL 4. Weight of the installed system shall not exceed more than 5-psf MUST BE COMPLETE FOR C.O. 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and ALL CONSTRUCTION SHALL MEET THE inspection. FULL HOUSE ROOF PLAN REQUIREMENTS OF THE CODES OF NEW SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building YORK STATE. NOT RESPONSIBLE FOR and other structures of the ASCE 7-16 and the 2020 New York State Residential DESIGN OR CONSTRUCTION ERRORS. Code. PVICOMPLY WITH ALL CODES OFELECTRfCAL mO JOB# 22601 I`!EW YORK STATS & TOWN CODES t INSPECTION REQUIRED COVER PAGE S REQUIRED AND CONDITIONS OF REVISION # N/A SOUTHOLD TOWNZBIt 5Connec4 m SUNATION SOUTHOLD TOWN PLANNING MANOu�Si�e� IQI_ �`� aid l ��1 REVISED BY N/A SOUTHOLD TOWN TRI SM rP � � access'i.blz . N.Y.S. DEC OF NFly CIRCUIT 3 GUTTER y a , FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard Sayville,New York,11782 n% Licensee No.074659 (631)-786-4419 u-r Bill@Fisher-NY.com • • • • 10 • • • 4 • • • • • • • • • • • • • • 0000 %00 ° • :• - ROOF 3 SUNATION J --y AA - SUNation Solar Systems 171 Remington Blvd. RIDGE Ronkonkoma,New York 11779 _^ (631)-75D-9454 Cj RIDGE ° RIDGE CAPPING NYSERDA ¢�' �P-) INSTALLER 4355 13'-2y2" CIRCUIT2 NUMBER JOB NUMBER 13'-0Y2" 13'-3yj 22601 --- ROOF AREA • • t ¢ 2'-2y2" ,5'-s}¢ IV ROOF 1 V 'V1 — 13-0Y2' 1V PHOTOVOLTAIC MODULEi P. OT- 1� Z } N B'-9!2 O • N CM • O �Z T ROOF 2 - c°'o C Co cc y m V O cr LU 26-6 LL w - GUTTER CIRCUIT 1 CIRCUIT 2 t m U c CO) y 3 a cd a Attachment Spacing: Portrait Attachment Spacing: Landscape Roof# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner 1 FOH West Roof 12 2490 230 6.1/12 4811 32" 1611 641' 64" 481' 2 FOH West Roof 6 2490 220 5.9/12 4811 3211 1611 64" 64" 48" 3 BOH East Roof 14 690 230 6.1/12 48" 3211 1611 6411 64" 4811 N.T.S. Al -1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and �P� M setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof, to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. `ate ° 074659 `� Exceptions: 1. Detached, nonhabitable structures, including but not limited to FISHER ENGINEERING detached garages, parking shade structures, carports, solar SERVICES,P.C. 509 Sayville Boulevard trellises and similar structures, shall not be required to provide q P Sayville,New York,11782 roof access. —(14) PROPOSED PV MODULES Licensee No.074659 2. Roof access, pathways and setbacks need to be provided (631)-786-4419 where the building official has determined that rooftop _ Bill@Fisher-NY.com operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two SUNATION units vertical in 12 units horizontal (17-percent slope)or less [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches ROOF 171 Remington Blvd. CCESS (914 mm) wide, shall be provided on all buildings. Not fewer than one A 36" For Ronkonkoma,New York 11779 A (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. - For each roof plane with a photovoltaic array, a pathway not less than Ai iA ❑ 36 inches (914 mm) wide shall be provided from the lowest roof edge IN SALLE 4355 to the ridge on thee same roof plane as the photovoltaic array, on an INSTALLER NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fightersj ACCESS JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal \ 18" - VENTILATION ROOF - - ---- - obstructions such as vent pipes, conduit, or mechanical equipment. 18" -VENTILATION 2260 1 Pathways on opposing roof slopes shall not be located along the same plane as the truss, rafter, or other such framing system that supports 18" - VENTILATION the pathway.a p y 18"-VENTILATION Exception: j 18" - VENTILATION 1. Access pathways shall not be required on roof slopes containing photovoltaic modules, panels, or an array where the opposing wlvvvv w or adjacent roof slope is an access roof. VV Z z oN Access Roof-A roof surface that: ROOF a) r T ACCESS Q m n o 1. Can be accessed from the ground by the fire service. 36" 2. Is capable of providing fire service access to the ridge or peak D w of an opposing or adjacent roof surface that contains VB LL -J LU photovoltaic modules, panels,or an array. ( ) ' U) 3. Is relatively free of vents, skylights,conduits, mechanical MSP IQ AC W CO '- (6) PROPOSED PV MODULES- 1= = m equipment and other such obstructions. __ == DSC � 0r 4. Does not contain photovoltaic modules, panels or an array, or is ATS $$C D m a single ridge roof where the maximum edge to edge width of U g o the photovoltaic panel system does not exceed 33 percent of i the ridge length. (EXT) [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be (12) PROPOSED PV MODULES- located less than 18 inches(457 mm)from a horizontal ridge. FRONT OF HOUSE - FACING STREET OR DRIVEWAY [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm) wide shall be provided to the emergency escape and rescue opening. N.T.S. A1 =4 ROOF ACCESS PLAN ��- OF_ NFA Typical Attachment Method w ° 074659 �� RIDGE y SNAP'N'RACK ULTRA RAIL ` �L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING PHOTOVOLTAIC -7 15-5.5„ SERVICES,P.C. MODULE 509 Sayville Boulevard ® Sayville,New York,11782 Licensee No.074659 3/4” MODULE SPACING (631)-786-4419 BETWEEN ROWS AND Bill@Fisher-NY.com (2)S.S.304 5.OMM X 60MM COLUMNS (TYP.) WOOD SCREW FASTENER SUNATION RT-MINI ROOF 0 ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LAYER ASPHALT 4 355___ 2' X 6 / 16" O.C. NUMBER(TYP.) / NSTALLDER / NUMBER JOB NUMBER 22601 PLYWOOD DECKING (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP.) WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP* 12'-3" ROOF SECTION (TYP.) rn N SCALE: N.T.S. T N } o Z N T SOLAR MODULE FRAME 0 0 00 0 O NOTE:3/4'SPACING F C 1 BETWEEN MODULE ROWS Q _ Roof# Rafter Size/Spacing Max Span Material Layers Sheathing T m U AND COLUMNS. � fn (D LLJ 1 2"x 6"/16"O.C. 12'-3" Composite Shingles 1 Plywood 55 HEIGHT ADJUSTABLE O J —j L-FOOT(TYP.) Z 2 2"x 6"/16"O.C. 10'-8" Composite Shingles 1 Plywood END CLAMP w LU U) 3 2" x 6" / 16" O.C. 11'-10.5" Composite Shingles 1 Plywood N 0 SNAP'N'RACK U Iz m �B. ULTRA RAIL O C: (TYP.) HEIGHT OFF OF M ROOF SURFACE C Q RT MINI 2 (TYP-) Typical Module PEST WRAP CUT Side Profile AWAY FOR CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER - SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GRO LOAD NOW SPEED(MPH.) TOEFOFECTSHIC SPECIAL WIND ZONE WIND BORNE ONEDEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE S 1 1 20 PSF 140 B NO 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE OF NE�y F's �0 s Foa�OF .074659�\? ES'i0 FISHER ENGINEERING SERVICES,P.C. 509 Sayville Boulevard Enphase A/C Branch Circuit (typ.) Sayville,New York,11782 _ 120/240v Licensee No.074659 UTILITY (631)-786-4419 SERVICE Bill@Fisher-NY.com ti Enphase Microinverter(typ.) N ti SUNATION COMBINER J Module J-Box(typ.) PANEL SUPPLY-SIDE n A CONNECTION 'V' SUNation Solar Systems 171 Remington Blvd. _F Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 100A INSTALLER R 4355 1 IN EGC Attached To Rail(typ.) MAIN J NUMBER ENPHASEGATEWAY 5. JOB NUMBER (No bads.wndwn9 m�Y) ---�� — 2P15A 22601 Eptuw Ca w CONDUIT AND CONDUCTOR SCHEDULE 2P2QA ENPHASE BRANCH CIRCUIT#1 C.rcud#1 TAG CONDUCTOR CONDUIT RUN r` – ENPHASE BRANCH CIRCUIT:'12 C2cuRW2 60A TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#3 �P�A MAIN s _ 1 Enphase Q-Cable 12 6 N/A N/A 15' EGC arouit k3 2 Type NM 10 6 N/A N/A 30' G G G MAIN � 3 HWN-2 10 6 PVC SCH.80 1.25" 15' 1 2. 3 ENPHASE A1C SERVICE IQ COMBINER DISCONNECT PANEL GC 8 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR r N SERVICE RATED N 4 HWN-2 6 3 PVC SCH.80 1.25" 10' 4 ENCLOSURE 6 z N GC 8 1 PVC SCH.80 1.25" 10' — MIN.60A — N MIN.22k AIC Z ,- 5 HWN-2 6 3 PVC SCH.80 1.25" 10' — 0 � Q 00 6 GC 6 1 N/A N/A 10' BUILDING Q GROUNDING '7 ELECTRODEU tv 0fr (3 W Z u) - J Circuit# PV Module Oty. Micro-Inverter Oty. Maximum AC Operating Current Q) u 1 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US 11 13.31 A N U m 2 REC405 Pure Black 10 Enphase I08PLUS-72-2-US 10 12.1 A o ?: 0 cz 3 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US 11 13.31 A 0 0 Maximum AC Operating Current(Total) 38.72 A E1 = 1 ONE-LINE DIAGRAM pF NFA LABEL LOCATION: LABEL LOCATION: ,�Q .�off' �•F,s — _ 0� WARNING: PCONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ Disconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. POWERSOURCE NEC 2017 690.31(G)(3) NEC 2017 705.10 /o.074659PAOTO `�� LABEL LOCATION: Second D • - � OFE A MAXIMUM AC OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Located next to Meter Pan FISHER ENGINEERING CURRENT VALUES ON DISCONNECT LABEL. SERVICES,P.C. NOMINALOPERCURRENTATING 509 Sayville Boulevard NEC 2017 690.54/NEC 2017 690.13(B) Sayville,New York,11782 NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 THE BUILDING MAIN SERVICE DISCONNECT. (631)-786-4419 Bill@Fisher-NY.com This building is equipped with an WARNING Service Disconnect Interconnected Electric Power `✓ SUNATION Production Source ` Er, ELECTRIC SHOCK HA • • • SUNation Solar Systems ZARD Source Type: 171 Remington Blvd. Ronkonkoma,New York 11779 DO NOT TOUCH TERMINALS Solar Photovoltaic TERMINALS ON BOTH THE LINE AND P ServiceDisconnect Disconnect is Located: Interior: (631)-750-9454 LOAD SIDES MAYBE ENERGIZED Located Service in Main PanelBasement:_ Garage Exterior. NYSERDA 4355 IN THE OPEN POSITION Front:_ Rear:---- LH side: PHOTOVOLTAIC INSTALLER F;H Side: Other Location. NUMBER F'�-IOTDVOLTAIC MODULES PRODUCE DC VOLTA(' - WHENEVER THEY ARE BOLDED TOSLNJGHT SUNation Solar Systems EQUIPPED WITH WID 631-750-9454 JOB NUMBER www.sunation com SHUTDOWN 22601 T CV T CV O r\ z N Z W a T L O C O 00 CU O a� U. � U W Z J W N U U c m o CZ 0 M Cz O 't E2= 1 PV LABELS OF NF o 46 Vot T ♦I FISHER ENGINEERING \� SERVICES,P.C. 509 Sayville Boulevard Sayville,New York,11782 Licensee No.074659 (631)-786-4419 Bill@Fisher-NY.com R SUNATION &�14 SUNation Solar Systems y > "+ �. 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 a y. N SSTALLE IN ALLEERDA 4355 `+. NR NUMBER JOB NUMBER 22601 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF vj- T N ! r N > O Z 0 c O 00 N O ' cc U y 0 (D �F LLJ' 'l ' U. i _ J oamn.u.nu;no' 01 W 098386266 W i it to Q. L w .0 SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP GI = I PV PHOTOS y Fisher Engineering Services, P.C. 509 Sayville Blvd• Sayville •New York 11782 Phone: (631) 786-4419 August 12, 2022 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Charters Residence-40 Madison Street, Greenport,NY 11944 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020-Residential Code of New York State(2020 RCNYS),Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code, NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x6" on 16" c.c., with an actual span of 12'-3", 10'-8", 11'-10.5", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, NE William G. Fisher, P.E. Licensed Professional Engineer h t r Corr, Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections k. �s::{ X:•R v.�. t t „+�: ; RE[ ALPH (X 3? �K .rt PURE 5ERIE PRODUCT SPECIFICATIONS: = 4 r: 400wpJt, ' • I 20.3 w//-F/T 2 f,\_4 Sss, R E C PROOUET 5PECIFICATIOKN5 SOLAR'S MOST TRUSTED 1821±2.5[71.7±0.11 za n.11 901[35.51 460[18.11 (1I CERTIFICATIONS IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ...........-................... ................ ❑ + ISO 14001:2004,ISO 9001:2015,OHSAS 18001:2007,IEC 62941 ` 1100[43.31 o�E 0-a r Intertek 6.0±0.2 10.24±0.011 '- + WARRANTY s _ _ m Standard: REC ProTrust +1 FIVII u * 1 nsta[led by a n REC Certified Solar Professional No Yes Yes o 11+0.2 a __.__._.. _............._..._....... o[0.43±0.011 System Size Al[ 625kW 25-500kW 16 ........._......................_................................ Product Warranty(yrs) 20 25 25 z0.s±o.s Power Warranty(yrs) 25 25 25 [o.a±0.021 1200[47.21 - Labor Wa rranty(yrs) 0 _ 25 10 ' f Power in Year 1 98% 98% 98% Annual Degradation 0.25/0 : 0.2S/o 0.25/0 o 0 0 z2 ..._..._......._._.......___..__._.____...___.................... s[0.91 671±3[26.4±0.121 Power in Year 2S 92% [ 92% 92% ��45[7.8] - _�30[1.21 5ee warranty documents for details.Conditions apply Measurements in mm[in] t GENERAL DATA __ i• MAXIMUM RATINGS 132half-cut REC heterojunction cells St5ub[iMC4PV-KBT4/KST4,12AWG(4mmz) Operationaltemperature: -40...+185°F(-40...+85°C) ............................................................................................................ Celltype: with lead-free,gaplesstechnology Connectors: in accordance withlEC62852 .M.a ximumsystemvoItage: 1000V 6 strings of22 cells in series IP68 only when connected ........................................................ ........................................................ .... .................................(...........................g.................. ...................................,...............-.........-.I.............�.. Maximum test load(front): +7000Pa(146lbs/sq ft). 0.13 in 3.2 mm solar lass with 12AWG 4mm PVwire,43+47in 1+1.2m -.......-- . ............ - -- ............- Glass: Cable: anti-reflection surface treatment accordancewithENS0618 Maximum test load(rear): -4000Pa(83.5lbs/sq ft)' Backsheet: Highly resistant polymer(black) Dimensions: 71.7x 40 x1.2 in(1821 x 1016 x 30 mm) Maxser[esfuserat[ng: 25A Max reverse current: 25A o Frame: Anodized aluminum(black) Weight: 45 lbs(20.5 kg) 'See installation manual for mounting instructions. ... . ... .. ........ . .......................................... . .. ............... ................. .................................................. Design load-Test load/1.5(safety factor) t 3-part,3 bypass diodes,IP68 rated 3 Junction box: inaccordancewithIEC 62790 Origin: Made in Singapore g `y` ELECTRICAL DATA m- tt Product Codec RECxxxAA Pure A TEMPERATURE RATINGS- M Power Output-PM (WP) 385 390 395 400 405 Nominal Module Operating Temperature: 44 C(±2°C) ........ .. ............. ... .............._....... ........ ................................................. . ....... .-... Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Temperature coefficient OfPMAx: -0.26%/°C ................. . ....................................................................................... ..............-...............................................................................I............... o Nominal Power Voltage-VMPP(V) 41.2 41.5 41.842.1 42.4 Temperature coefficient ofVoc: -0.24%/eC .............. ... ....................................................................................... ................................. ................................................................................. u Nominal Power Current-IMPP(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficient oflsc: 0.04%/°C a I ...................-.................................. .. . .. ..... ............................ ... ..... ..... . Ln Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 The temperature coefficients stated are linear values . ......................................_.................................. Short Circuit Current-Isc(A) 10.10 10.15 10.20 10.25 10.30 ....... ................ ... ._._ _.................._..............._...__._................_.....................I.. ..................- Power Density(W/sq ft) 19.3 19.6 19.8 20.1 20.3 L0 LIGHT BEHAVIOUR _............... . ..... ............_............................................ .... ......._.................................................. Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical lowirradianceperformance ofmodule atSTC: ni 0 Power Output-PMA.(WP) 293 297 301 305 309 _ ................................................ .............................................................. ... ....... . F Nominal Power Voltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0CF Q .... ._. .. .. ..... ........ ................ :............................_..........- -...-......._... .............._..... j-----------------j---------j--------! o g Nominal Power Current- IMPP(A) 7.55 7.S9 7.63 7.68 7.72 - Z .......................... .................... Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 """""---" """."--_;"-_..._- ShortCircuit Current-Isc(A) 8.16 8.20 8.24 8.28 8.32 m m Imadlance(W/m')� Values at standard test conditions(5TC air mass AM13,irradiance 10.75 W/sq ft 0000 W/m'),temperature 77F(25°C),based on a production spreadwithatolerance ofP,„ ,Voc&Isc s3%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/m',temperature 68°F(20°C),windspeed 3.3 ft/s Q m/s).`Where root indicates the nominal power class(PMS)at STC above. Founded in 1996,REC Group is an international pioneering solar energy (` n r/- company dedicated to empowering consumers with clean,affordable REC solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational a headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. ENPHASE. ka W -- Ilk IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling np High productivity and reliability i Produce power even when the 25 i; year limited grid is down rranty - • More than one million cumulative Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, • Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED • Complies with the latest L SAFETY advanced grid support Connect PV modules quickly and easily to I08 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA IDCI 198-60-2-US1 Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module[so] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1 I: 1 1: Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 i Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -4000 to+600C(-40OF to+1400F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBSP-DS-0002-01-EN-US-2021-10-19 l SEP-IES 100 FLASHED L FOOT KIT SnapNrack - .l PV Mounting Systems The SnapNrack line of soar mounting systems is designed to reduce total '�q��.}G,y4a4:.i Y=� ,•$�'Y 0%4.-�T h`n if.�fYyt'�ji `'•''.-.]N��:r! ,r�.��:Fr(�i.,���1yir.: y�••r'ti.-nrSi"s:'ry ry�}.`fix_r ;.- ='-=-:o. installation costs. The system features ,�- 'Iny""p n., 5n'+yi�. f;^,CS'r.'f'i•' .....C�h` technical innovations proven on more than 20OMW of solar projects to simplify ' a ,'l`: '� Via'',-�'1r'p'LG.>'-r„ •ya•:y installation and reduce costs. ;�,- -_�. •:��. , -� �,-„�.d ,�-}y Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative •r solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps• shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1”slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending FW Mi )UhuCr�i o 32yeftp-m�n c •i `'-����'`^--' •,.\ SFr ®"�� Flashed L Foot Kit Assembled(I'spacer sold separately) Flashed L Foot Kit Parts(I'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions r-SNAPNRACK CHANNEL NUT ' SNAPNRACK 92 DEGREE L-FOOT,CLEAR 5/1618 FLANGE NUT 511618 X LIN BOLTWITH SPLIT LOCK WASHER m -SNAPNRACK COMPOSmON FLASHING 3.93 SNAPNRACK L-FOOT BASE SnapNrack Flashed L Foot Data Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship Snap'N\,,� rack, FIA , (877) 732-2860 www.SnapNrack.com *0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. 4 i LP SERIES 100 ROOF • SnapN'rack Solar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive ;f`y down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient visually appealing, hotovoltaic PV module installation system. Series 100 UL is Listedto the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) IdentifySite Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide ( Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required I i • Proprietary SnapNrack grounding lug snaps in the rail _ channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules O L. LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Standard Rail SnapNrack Banding P Bolt with Split- Splice Insert Al Split-Lock Washer Lack Washer SnapNrack Banding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding Bonding SnapNrack Stainless Adjustable End Channel Nut Bonding Bolt with Clamp Bottom Channel Nut Stainless Hardware with • Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire �� — •®' SnapNrack Ground Lug g Assembly ■ a (ONE REQUIRED PER ROW OF ■ • MODULES) SnapNrack Bonding Universal ■ t End Clamp(UEC)Wave UEC Pull Strap ®�,��,•�r®���ros®�.�®r: UEC Wedge Stainless Steel Bolt —1®est with Flat Washer IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff CIamP Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut •, Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff o SnapNrack SnapNrackJ All Purpose Mill Finish L Foot Standoff All Base(1-Hole SnapNrack Base Shown) SnapNrack A Metal Roof Mill Finish L Foot Base Assembly L Foot Base Flashing SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff AssemblyRoof Base with L Foot Base with Flashing Bonding L Foot SnapNrack • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) S na p ra c k- solaf (877) 732-2860 www.SnapNrack.com Zi Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.Allinghts reserved. I OF FISHER ENGINEERING �� . . SERVICES,P.C. 509 Sayville Boulevard r. _ = =¢,= \ a�r j ' •, i Sayville,New York,11782 Licensee No.074659 r r _,• (631)-786-4419 Bill@Fisher-NY.com SUNNTfON r SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 ■ ` ; (631)-75D-9454 ERDA • - _ - 1� !' _- - - _. � F`�•! - NTINSALLE R BER 43551 — '�.- JOB NUMBER 22601 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF a � CV r- N i z CV _ N 1 W L )✓ O a) I? CD 00 •� "�__ , ;4 „J ' .it � � � U W'I Y t LL „ "'138f W L898386266 Q w L O C �i min y �- O d- r -. I ,r Mj SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 = 1 PV PHOTOS OF NES FISHER ENGINEERING Enphase A/C Branch Circuit(typ.) SERVICES,P.C. 509 Sayville Boulevard . . . . . . . Sayville,New York,11782 120/240v Licensee No.074659 UTILITY (631)-786-4419 Enphase Microinverter(typ.) ti --- SERVICE Bill@Fisher-NY.com 4 COMBINER SU pN�1 N � 14 Module)-Box �^" ,�R.-'}���Y ��, t✓ (typJ- _--- . PANEL SUPPLY-SIDE n n CONNECTION '\Y/I SUNation Solar Systems 171 Remington Blvd. PV Module(typ.) Ronkonkoma,New York 11779 (631)-750-9454 EGC Attached To Rail(typ.) NYSERDA MOON 1 INSTALLER 4355 MAIN I NUMBER ENPHASE GATEWAY 5 JOB NUMBER (No loads,monitoring only) f� 2P1 E G.—, 226015A — au CONDUIT AND CONDUCTOR SCHEDULE 21`20A �1 — ENPHASE BRANCH CIRCUIT#1— Circuit#1 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 2P2pA TYPE GAUGE QUANTITY TYPE SIZE LENGTH Circuit#z 60A ENPHASE BRANCH CIRCUIT#3 2P20A MAIN s, _ 1 Enphase Q-Cable 12 6 N/A; N/A 15' EGC Circuit#3 2 Type NM 10 6 N/A N/A 30' G G G 3 HWN-2 10 6 PVC SCH. 80 1.25" 15' 1 2 g ENPHASE MAIN a IO COMBINER A/C SERVICE 0) GC 8 1 PVC SCH. 80 1.25" 15' ROOF ATTIC EXTERIOR DISCONNECT PANEL T- CV 4fGC WN-2EE 6 3 PVC SCH.80 1.25" 10' SERVICE RATED T N ENCLOSURE } O 8 1 PVC SCH.80 1.25" 10' 4 MIN. OS 6 Z N MIN.22k AIC r- T 5N-2 6 3 PVC SCH.80 1.25" 10' O C O o\p 6 6 1 N/A N/A 10' BUILDING Q N a o GROUNDING r ELECTRODE N V Circuit# PV Module Ot LLO Cn U - J Y Micro-Inverter Oty. Maximum AC Operating Current w 0) W rA 1 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US 11 13.31 AZ U) 4, U c m 2 REC405 Pure Black 10 Enphase I08PLUS-72-2-US 10 12.1 A o c 3 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US0 Cz 11 13.31 A Q � o I �r i Maximum AC Operating Current(Total) 38.72 A ' �I E1 - 1 ONE-LINE DIAGRAM OF NFGG MG.G. �P\\o Fsh �O s� .o °•074659 FISHER ENGINEERING SERVICES,P.C. Enphase A/C Branch Circuit (typ.) 509 Sayville BoulevardSayville,New York,11782 120/240v Licensee No.074659 UTILITY (631)-786-4419 SERVICE Bill C�Fisher-NY.com ti Enphase Microinverter(typ.) ... N SU t y� gam@,� M COMBINER SUNA 1 ION Module J-Box(typ.) FPANEL p c 3E a1-4 y SUPPLY-SIDE n n CONNECTION '\Y/' SUNation Solar Systems • • 171 Remington Blvd. PV Module(typ.) Ronkonkoma,New York 11779 (631)-75D-9454 EGC Attached To Rail(typ.) \\\ NYSERDA 100A \ INSTALLER4355 MAIN J NUMBER ENPHASE GATEWAY 5 JOB NUMBER (No loads,monitoring only) f\ _ -� -� - 22601 2P15A Epp ase Gateway CONDUIT AND CONDUCTOR SCHEDULE zPzoA s — ENPHASE BRANCH CIRCUIT#1 Circuit#1 TAG CONDUCTOR CONDUIT RUN zPzoA ENPHASE BRANCH CIRCUIT#2 Circuit 4, 2 60A TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#32P20A MAIN s _ 1 Enphase Q-Cable 12 6 N/A N/A 15' EGC Circuit#3 2 Type NM 10 6 N/A N/A 30' G G G 3 HWN-2 10 6 PVC SCH. 80 1.25" 15' 1 2 3 ENPHASE A/C MAIN SERVICE I) IO COMBINER DISCONNECT PANEL GC 8 1 PVC SCH.80 1.25 15 ROOF ATTIC EXTERIOR � CV SERVICE RATED N 4 HWN-2 6 3 PVC SCH. 80 1.25" 10' ENCLOSURE } O GC 8 1 PVC SCH.80 1.25" 10' 4 MIN.60A 6 z N MIN.22k AIC tv T 5 HWN-2 6 3 PVC SCH.80 1.25" 10' _ 6 GC 6 1 N/A N/A 10' `� BUILDING a a) 0 0 N Q O GROUNDING r ` ELECTRODE U 1 0 (3 LU Circuit# PV Module Qty- Micro-Inverter Qty. Maximum AC Operating Current w ami � CZ 1 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US 11 13.31 A ~ U) U c 2 REC405 Pure Black 10 Enphase IQ8PLUS-72-2-US 10 12.1 A 0 3 Cz 3 REC405 Pure Black 11 Enphase IQ8PLUS-72-2-US 11 13.31 A � O I -- Maximum AC Operating Current(Total) 38.72 A E1 = 1 ONE-LINE DIAGRAM