Loading...
HomeMy WebLinkAbout48365-Z �OS�EFO( y Town of Southold 1/12/2023 P.O.Box 1179 W 53095 Main Rd �d Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43754 Date: 1/12/2023 THIS CERTIFIES that the building HVAC Location of Property: 1300 Park View Ln, Orient SCTM#: 473889 Sec/Block/Lot: 15.-5-24.22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/19/2022 pursuant to which Building Permit No. 48365 dated 10/3/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: 5 mini split-ductless air conditioning units and heat pump system to a single family dwelling as applied for The certificate is issued to Katechis,Joanne&Stamoulis,Gregory of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48365 12/6/2022 PLUMBERS CERTIFICATION DATED Authoriz d ignature gUFfD(G BUILDING DEPARTMENT oo TOWN CLERK'S OFFICE y x SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48365 Date: 10/3/2022 Permission is hereby granted to: Katechis, Joanne 1300 Park View Ln Orient, NY 11957 To: Legalize the installation of 5 mini split-ductless A/C & heat pump system to a single family dwelling as applied for. At premises located at: 1300 Park View Ln, Orient SCTM # 473889 Sec/Block/Lot# 15.-5-24.22 Pursuant to application dated 8/19/2022 and approved by the Building Inspector. 11 To expire on 4/3/2024. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $180.00 Total: $630.00 Building Inspector 0f SO!/T�ol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 OI�COUIVV,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joanne Katechis Address: 1300 Park View Ln city:Orient st: NY zip: 11957 Building Permit#: 48365 Section: 15 Block: 5 Lot: 24.22 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement - Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 5 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 8 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 5 Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " 5 Mini Splits Inspector Signature: Date: December 6, 2022 S. Devlin-Cert Electrical Compliance Form OF SOUTy�Io Lq 10 ?7&6 r 15300 to lv"I �� f # TOW` N OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) N-S& ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE Z Z7i INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS b t� FOUNDATION (1ST) W ------------------------------------ FOUNDATION (2ND) ' z 1A ROUGH FRAMING& PLUMBING �r INSULATION PER N.Y. , a STATE ENERGY CODE FINAL ADDITIONAL COMMENTS i-lo - V1 z m ;o � O S t� b o z x d ro TOWN OF SOUTHOLD—BUILDING DEPARTMENT G Town Hall Annex 54375 Main Road P. O. Box 1179,Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only / AUG 1 9 2022 PERMIT NO. 365 Building Inspector: Applications and forms must be filled'out in their entirety.Incomplete TOrlv:� Gc applications will not be accepted. 'Where-the Applicant.is not the owner,an- .. Owner's Authorization form(Page 2)'shall be completed. Date: OWNER(S)OF PROPERTY:- Name: _Fs_ #1000- _ Project Address: IS:,�16 Phone#: Z Email: Mailing Address: CONTACT PERSON: Name: Mailing Address: Phone#: DESIGN PROFESSIONAL.INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR'I N FORMATION: Name: Mailing Address: Phone#: Email: -DESCRIPTION OFr PROPOSED CONSTRUCTION [:]NewStructure ❑Addition ❑Alteration QRepairDemo i Estimated Cost of Project: ❑Other t`�J ,11/� /Z/%�1/I ,�,�L17— $ Will the lot be re-graded? ❑Yes []No Will excess fill be removed from premises? ❑Yes F-1 No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone- Ordinance of the Town of Southold,Suffolk,County,New York and other applicable'Laws,Ordinances or Regulations;for the construction of buildings,, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises-and in building(s)for necessary inspections:False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pri t name : []Authorize Agent CblOwner Signature of Applicant: Date: 1 a STATE OF NEW YORK) SS: COUNTY OF Sul Fo I-K ) ,2 oa o eKa±eLh 15 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the C),'on,,:F, (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1°I*hday of U 209 A (XJh�J 0 �UUVA tary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION NO.01 DW6306900 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,202_� I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Dep ment for approval as described herein. Owner's Signature Date Print Owner' ame 2 BUILDING DEPARTMENT- Electrical Inspector �► © TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 *.aye Telephone (631) 765-1802 - FAX (631) 765-9502 ro.gerrc@.southoldtownny.gov — seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request,an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: ,3079nf✓G` /Iq 21*11 Address: /SOD Cross Street: Phone No.: 3%�77.7 Bldg.Permit#: 6 2��p 5 email: Tax Map District: 1000 Section: S Block: 5 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): /�`S S�eV}� S uare Foota e: M Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 0-P-Ace, APPROVED AS NOTED COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES DATE'10-3-A'A B.P.# 4 3 5 AS REQUIRED AND CONDITIONS OF FJIo30 Ob BY J9 Y�r SOUTHOLD,T,,OW ZBA NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE SOUTHOLD-TOM PWNMBCAFD FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED SOUTHOLD TOWNTRtg= • _ FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, N.YS.DEC STRAPPING, ELECTRICAL&CAULKING 3. INSULATION 4. FINAL-CONSTRUCTION &ELECTRICAL -A MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS. AkkMITSUBISHI L RIC WAL11MG Split-ductless A/C and Heat Pumps T 1 • 1 • • •HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES -- - _ ___—_— - _—-- •Wall-mounted indoor unit for residential and small commercial �2 applications •Standard Hybrid Catechin Prefilter is included with indoor unit g� •Quiet operation ��. •"Powerful Mode"function permits system to temporarily run ata �i '— ( lower/higher temperature with an increased fan speed,which Indoor Unit:MSZ-A09NA , quickly brings the room to the optimum comfort level •Wireless remote controller Is Included;PAR-21 MAA wired 444_ remote controller can be installed as an option •Indoor unit powered from outdoor unit using A-Control Outdoor Unit:MUZ-A09NA •Auto fan speed control;auto restart following a power outage Wireless Remote Controller •Limited warranty:five years on parts and defects and seven years Indoor Unit on compressors MCA...............................................1 A Fan Motor............ .....................0.76 F.L.A. OPTIONAL ACCESSORIES Airflow(Lo-Med-Hi-Powerful) Outdoor Unit Cooling .....................152-229-307-338 Dry CFM 134-205-275-303 Wet CFM •Drain Socket Assembly(MAC-851 DS) Heating 159-222-307-321 CFM Indoor Unit Sound Pressure Level(Lo-Med-Hi-Powerful) . •M-NET Control Adapter(MAC-3991F) Cooling ........................... 22-33-38-41 dB(A •MA Contact Terminal Interface(MAC-3971 F) Heating ............................ 22-33-38-39 dB(A; •Wired Remote Controller(PAR-21 MAA;requires MAC-3971F) •Condensate Pump(230V;S13100-230) DIMENSIONS UNIT INCHES/MM •Anti-allergy Enzyme Filter(Two pieces per set;MAC-1415FT) W 30-11/16/780 •Three-pole Disconnect Switch(TAZ-MS303) D 8-1/4/210 Cooling* H 11-3/4/298 Rated Capacity................................9,000 Btu/h Weight.....................................23 lbs./10 kg Minimum Capacity..............................5,500 Btu/h External Finish .....................Munsell No.1.OY 9.2/0.2 SEER............................................ 17.0 Field Drainpipe Size O.D......................6/8"/15.88 mm Total Input........................................690 W Remote Controller . Wireless .... ......... ............. Heating at 47°F* (Optional Wired Remote Controller.PAR-21 MAA; Rated Capacity...............................10,900 Btu/h see Data Submittal Sheet) Minimum Capacity .............................5,200 Btu/h HSPF ............................................. 8.2 Outdoor Unit Total Input........................................860 W Compressor.............................DC-driven Inverter Heating at 17°F* MCA..............................................12 A Rated Capacity................................6,400 Btu/h Fan Motor.....................................0.52 F.L.A. Input........................................700 W Sound Pressure Level Total In P Cooling/Heating............................48/48 d6(A) •Rating Conditions(Cooling)-Indoor.80°F(27°C)DB,67°F(19°C)WB;Outdoor.95°F (35°C)DB,75°F(24°C)WB. (Heating at47°F)-Indoor.70°F(21°C)DB,60°F(16°C)WB;Outdoor.47°F(8°C)D6,43°F(6°C)WB. DIMENSIONS INCHES/MM (Heating at 17°F)-Indoor.70°F(21°C)DB,60°F(16°C)WB;Outdoor.17°F(-8°C)DB,15°F(9°C)WB. W 31-1/2/800 Power Supply....................208/230V,1-Phase,60 Hz D 11-1/4/286 Breaker Size....................................... 15 A H 21-5/8/550 Voltage Indoor-Outdoor S1-S2 ......................AC 208/230V Weight ....................................75 lbs./34 kg Indoor-Outdoor S2-S3 .........................DC 12-24V External Finish......................... Munsell 3Y 7.8/1.1 Indoor-Remote Controller.........................Wireless OPERATING RANGE Refrigerant Type...................................R410A Refrigerant Pipe Size O.D. Indoor Intake Air Temp. Outdoor Intake Air Temp Gas Side.................................3/8"/9.52 mm DB 32°C °F( ) , 90 Liquid Side................................1/4"/6.35 mm Maximum 115°F(as°c)De Max.Refrigerant Pipe Length.....................65 ft./20 m 73°F 23°c we Max.Refrigerant Pipe Hei ht Difference ............40 ft./12 m Cooling 67°F(190c DB, Connection P 9 Minimum 57°F(14°C)WB 14°F(-10°C)DB n Method ................................ Flared Maximum 80°F(27°C)DB, 75-F(24-C)DB, 67°F 19°C WB 65°F 18°C WB Heating 70°F(21°C)DB, 14°F(-10°C)DB, Minimum 60°F(16°C)WB 13°F(-11°C)WB 1 I T®RR DIMENSIONS: A1 ' MUZ-A09NA MSZ-A09NA .- �- 30-11i16 Conduit plate MSZ-A•NA- l II and MSY A•NA-0 are excluded. Unit: inch 7/16x1 Oblong hole 7/16x13/16 Oblong hole Installation plate 2-3/16 8-7/8 8-7/8 2-3116 7/8 ho e CD j Iii o ob ao 6 0 I 6-1/816-118 1-314 to 00 2-3116 [ 13-3/-16 12-5/8 2-3/4 Indoor unit Air in Wall hole o2-9/16 "8-1/4 3/16 Installation late 2-1/8J 24-9/16 4 Liquid line o1/4 19-11/16 2-5/161 I_ J 3/4 Gas line� o16 Insulation o1-l-3/88 O.D O.D I I I o3/4 LD Drain hose o5/8 Air out (Connected part O.D) Insulation o1-1/8 MUZ-A09NA Unit: inch REQUIRED SPACE Basically open 4 inch or more 15-3/4 without any obstruction in front Drain hole of-518 and on both sides of the unit. m Air in o(mole Air in b m i � 47�or w M mom 1-9/16 fq/ Air out or mGIB ormor 38x13116 C vaoe 7/8 29/32 11-1/4 17132 open two sides of left, handle / right,or rear side. m NAL N Liquid pipe :1/4(flared) Gas pipef:3/8(flared) MUZ-A09/12NA 1i 1:1/2(flared) MUZ-A15/17NA,MUY-A15117NA M 11-29132 6-23132 `n 1511 19-11/16 31-1/2 2-23/32 MITSUBISHI ENEnGY STAR ELECTRIC Ila n(tk HVAC Advanced Products Division ARI Standard 'Unitary Small HP 3400 Lawrenceville Suwanee Rd Suwanee,GA 30024 UA Tele:678-376-2900•Fax:800-889-9904 Toll Free:800-4334822(#3) wwwfirldro,101,011— www.mehvac.com C SD-MSZ-A09NA&MUZ-A09NA-200903 ©MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice. SUBMITTAL DATA: MXZ-3C24NA2 + MITSUBISHI MULINVERTER HEAT-PUMP SYSTEM ArIk ELECTRIC TI-INDOOR Job Name: System Reference: Date: i� Outdoor Unit:MXZ-3C24NA2 ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ❑ 1/2"x 3/8"PortAdapter(MAC-A455JP-E) ❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ M-NET Adapter(PAC-IF0IMNT E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C24NA2 Rated Capacity Btu/h 22,000/23,600 Cooling* Capacity Range Btu/h 12,600-22,000/12,600-25,500 (Non-ducted/Ducted) Rated Total Input W 1,620/2,100 Rated Capacity Btu/h 25,000/24,600 Heating at 47°F* Capacity Range Btu/h 11,400-30,600/11,400-29,400 (Non-clucted/Ducted) Rated Total Input W 1,750/1,900 Heating at 17°F* Rated Capacity Btu/h 14,000/14,000 (Non-ducted/Ducted) Rated Total Input W 2,120/2,230 Energy Star®(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Yes Power Supply Voltage,Phase,Hertz 208/23OV,1-Phase;60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC t24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB(A)A) 51 (Non-ducted/Ducted) Heating 55 External Dimensions(H x W x D) In(mm) 31711/32 x 37-13/32 x 13 796 x 950 x 330 Net Weight Lbs(kg) 137 62 External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(6.35) Eight Ports Gas(Low Pressure) A Port:1/2(12.7);Other:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU Ft(m)m) 49(15) Difference If IDU is Below ODU 49(15) Connection Method Flared/Flared Refrigerant R410A Rating Conditions perAHRI Standard: Cooling i Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at47°F i Indoor.70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at47°F i Outdoor.47°F(8°C)DB/43°F(6°C)WB Heating at 17°F i Outdoor.17°F(-8°C)DB 115°F(9°C)WB i Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: MXZ-3C24NA2 OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 20.0 13.6 9.8 4.2 2.97 Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) Ducted and 18.0 12.4 9.5 4.0 2.79 Non-ducted Ducted 16.0 11.2 9.2 3.8 2.61 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C24NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. I 1 OPERATIONAL , , I DUCTED: Operational CoolingCapacity IndoorPerformance for .- (Btu1h) Power Usage Range(W) Current(208/23OV) Unit Combinations Unit A Unit B Unit C 9 9000 0 '0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 9+9 9000 9000 0 10900 10900 0 9000 12000 0 9+12 TBD 9429 12571 0 9+15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+12 10900 10900 0 12000 12000 0 12+15 9689 12111 0 10667 13333 0 9+9+9 7867 7867 7867 8200 8200 8200 S Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc. t OPERATIONAL ■ ■ I • ■ ■ , ■ contd. NON-DUCTED: Operational CoolingCapacity IndoorPerformance for ge(Btu/h) Power Usage Range is O Unit Combinations (Unit A+Unit B+Unit C) Unit A Unit B Unit C 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 6286 15714 0 6+18 5450 16350 0 6000 18000 0 9+9 9000 9000 0 11000 11000 0 8571 11429 0 9+12 9429 12571 0 TBD 9+15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+12 10900 10900 10 12000 12000 0 12+15 9689 12111 0 10667 13333 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7086 7086 10629 6+6+12 5500 5500 11000 6250 6250 12500 6+6+15 5333 5333 13333 5556 5556 13889 6+9+9 5500 8250 8250 6250 9375 9375 6+9+12 5333 8000 10667 5556 8333 11111 9+9+9 8000 8000 8000 8333 8333 8333 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: Unit: inch(mm) -7/8' 23-5/8' 6-7/8' Rem Av Intake 2-13/16' 9- 2' 2-1/32' 3-I1/16' 2-O Sha ed Notched Hole 13/32 )Foundation Bolt M701 3-3/3 m n � t Side Air Intake 4 m m a N 6-/1-5/16'Orain Hale Av iv 13/32' m �aLschOrge 13/32' 2-(15/32'x1-13/32'1 Oval Hole 1-1/32 2-07/8'knockout hole (Foundation Bolt M10) 1-1/2• (Connectin wire hole) 1-5/8' 37-13/32' 31/32' 13' 19/32' 3-/7/8'punchetl hole IConnecting wire hole) HanO ^� ` Hwtlle =01. Hn kV Handle n � 0 O® Air Intake Nm Q LID GAS t UNI C 11-1.121S-ARE® =Cal LW UnlBGAS 3/810952]FLARE =O® GAS J LIa t UNI A•LIa 1/410635FLARE GAS J GAS 1/2'10WIFLARE _U v 1-11/32 14-7/32' 1.FREE SPACE v E O E E 3-15/16' or mare m n 0 p f7- /16'or more13-25/32'or more Conduit plates 2.SERVICE SPACE Conduit connector E 1 \y E Lock nut 3-15/16' or mare SERVICE SPACE 13-25/32'or more _13-25/32' or more _ I MITSUBISHI M+W ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com CETA us U0nE0 FORM#MXZ-3C24NA2 for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc. SUBMITTAL D. MSZ-GL09NA MITSUBISHI 9,000: INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS ArIk ELECTRIC Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL09NA ®UU' I GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-GL09NA Cooling Capacityl,3 BTU/H 9,000 Heatirig Capacity2.3 BTU/H 10,900 Voltage,Phase,Frequency 208/230V,1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight --r--Lbs.(kg) 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Notes: 'Cooling(Indoor//Outdoor) T 80 DB,67 WB//95 DB,75 WB Nominal Conditions 2Heating at 47T(Indoor//Outdoor) T 70 DB,60 WB H 47 DB,43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: 09 Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo touchT"/RedLINKTm Wireless Controller ❑MHK2 Deluxe MA Remote Controller) ❑PAR-40MAAU Simple MA Controller) ❑PAC-YT53CRAU-J Touch MA Controller) ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interfacet ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1 CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711-110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑X85-003 Fascia Kit for MicroBlue Pump–mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 • MSZ-GL09NA Unit: inch 1/16x1 Oblong hole 1116x13/I6 Oblong hole Installafion plafe 3-1/8 8 1/8 8 118 -1/8 31-1/16 �_ 30-15/16 1/4 0 co °� .6 n m m co 6-1/8-L6-1/8 J 13-5/16 13-9/16 1.2! 1/8 3/16 9 1/8 1 Air in all hole 43 Indoor unit fl �7 Installation late Q � � Pi rn N N — 97 N ■ M N 1-5/8 1-3/4 1-15/16_ 24-3/8 Drain hse 2 5/I6, 3/4 — About 4 3/ � 1 _ ■ eo Q �, Insulation o1-3/80.1) �Fi- Liquid line o1/4 19-11/16(Flared connection o114) Gas line o3/8 16-15/16 2 3/16 I 15/16 I 3/16 (Flared connection:o3/8(06/09112 KBTUIH),o112(15 KBTU/H) � Drain hose Insulation e1-1/8 O.D Connected part e5/8 0.13 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:8004334822 www.mehvac.com FORM#MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT PUMP cI us SYSTEMS-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SUBMITTAL DATA: MSZ-GL12NA MITSUBISHI 12,000:TU/H WALL-MOUNTED INDOOR Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL12NA SUIS. GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-GL12NA Cooling Capacity,3 BTU/H 12,000 Heating Capacity2,3 BTU/H 14,400 Voltage,Phase,Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 45-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight Lbs.(kg) 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Notes: lCooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB Nominal Conditions 2Heating at 47°F(Indoor//Outdoor) T 70 DB,60 WB//47 DB,43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo fouchTm RedLINKTm Wireless Controller ❑MHK2 Deluxe MA Remote Controller) ❑PAR-40MAAU Simple MA Controller) ❑PAC-YT53CRAU-J Touch MA Controller) ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interfacet ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet!8�and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1 CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711-110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(2081230V)[recommended] ❑X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑X85-003 Fascia Kit for MicroBlue Pump–mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 • ' Unit: inch 7/16x1 Oblong hole 1/16x13/16 Oblong hole Installation plate 3-1/8 8 7/8118 -118 „ 31-7/16 30-15/16 1/4 o m " °0 ab e 6 1/8 6-1/8 co 2-3/ 13-5/16J. 13-9/16 9-1/8 Air i0 all hole 03 3/16 Indoor unit fl �1fT7 LJ allation late N N - M � 1-3/4 I IS/I6 24-3/8 0IE5-1/8,� � MDrain hose 2-5/I� r314 Air out 0 ■ mQ I Insulation of-3/8 0.1) 'a Liquid line o1/4 19-11/16(Flared connection o1/4) u. Gas line o3/8 16-15/16 1,2-3/16 1-15/16 (Flared connection:o3/8(06109112 KBTU/H),o1/2(15 KBTU/H) 13/16 Drain hose Insulation of-1/8 0.1)Connected part o5/8 0.1) 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800433-4822 www.mehvac.com FORM#MSZ-GL12NA FOR MXZ-C MULTI-ZONE HEAT PUMP c�TI us SYSTEMS-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SUBMITTAL DATA: MXZ-3C24NA2 MITSUBISHI MULINVERTER HEAT-PUMP SYSTEM AWIL ELECTRIC TI-INDOOR Job Name: System Reference: Date: 1 ,u Outdoor Unit:MXZ-3C24NA2 ACCESSORIES ❑ 3/8"x 1/2"PortAdapter(MAC-A454JP-E) ❑ 1/2"x 3/8"PortAdapter(MAC-A455JP-E) ❑ 1/2"x 5/8"PortAdapter(MAC-A456JP-E) ❑ M-NET Adapter(PAC-IF01 MNT-E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C24NA2 Rated Capacity Btu/h 22,000/23,600 Cooling* Capacity Range Btu/h 12,600-22,000/12,600-25,500 (Non-ducted/Ducted) Rated Total Input W 1,620/2,100 Rated Capacity Btu/h 25,000/24,600 Heating at 47°F* Capacity Range Btu/h 11,400-30,600/11,400-29,4001 (Non-ducted/Ducted) Rated Total Input W 1,750!1,900 Heating at 17°F* Rated Capacity Btu/h 14,000/14,000 (Non-ductedlDucted) Rated Total Input W 2,120!2,230 Energy Star®(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Yes Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA ' A 22.1 Indoor-Outdoor S1-S2 V AC 208/230 Voltage Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB( )A 51 (Non-ducted/Ducted) Heating 55 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13• 796 x 950 x 330 Net Weight Lbs(kg) 137 62 External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(6.35) Eight Ports Gas(Low Pressure) A Port:1/2(12.7);Other:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU Ft(m)m) 49(15) Difference If IDU is Below ODU 49(15) Connection Method Flared/Flared Refrigerant R41 OA Rating Conditions perAHRI Standard: Cooling IIndoor..80°F(27°C)DB/67"F(19°C)WB Heating at47°FIIndoor..700F(21°C)DB/60°F(16°C)WB Heating at 171FIndoor:700F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at47°F I Outdoor.47°F(8°C)DB/43°F(6°C)WB Heating at 17°F Outdoor.17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted Heating 5 to 65•F(-15 to 18°C)WB (06+06+09) 20.0 13.6 9.8 4.2 2.97 Ducted and 18.0 12.4 9.5 4.0 2.79 Non-ducted Ducted 16.0 11.2 9.2 3.8 2.61 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C24NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. I 1 OPERATIONAL ■ ■ 1 , 1 ■ ■ • ■ 1 DUCTED: operational CoolingCapacity IndoorPerformance for Unit Combinations Unit A Unit B Unit C 9 9000 0 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 9+9 9000 9000 0 10900 10900 0 9000 12000 0 9+12 TBD 9429 12571 0 9+15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+12 10900 10900 0 12000 12000 0 12+15 9689 12111 0 10667 13333 0 9+9+9 7867 7867 7867 8200 8200 8200 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL PERF• 'MANCE, contd. NON-DUCTED: OperAtional Cooling .. IndoorPerformance for .. Usage is O Unit Combinations Unit A Unit B Unit C 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 6286 15714 0 6+18 5450 16350 0 6000 18000 0 9+9 9000 9000 0 11000 11000 0 8571 11429 0 9+12 TBD 9429 12571 0 9+15 8175 13625 0 9000 15000 0 9+18 7267 14533 0 8000 16000 0 12+12 10900 10900 0 12000 12000 0 12+15 9689 12111 0 10667 13333 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7086 7086 10629 6+6+12 5500 5500 11000 6250 6250 12500 6+6+15 5333 5333 13333 5556 5556 13889 6+9+9 5500 8250 8250 6250 9375 9375 6+9+12 5333 8000 10667 5556 8333 11111 9+9+9 8000 8000 8000 8333 8333 8333 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. I Unit:inch(mm) -7/8' 23-518' o Rear k 2-13/16' 9- 2- 2-1/32' 3-1/16' 2-U Sho ed Notched HDIe 13/32' IFoundotion Bolt M101 m N S°e Air Wake* m m P 6-01-5/16'Draln Hale oAr ,,, 3/32' m Discharge 13/32' 2-115/32'x1-13/32')Oval Hole 1-1/32' 2-07/8'knockout hole (Foundotion Bolt M10) 1-1/2• (Connectin wire hole) 1-5/8' I 37-13/32' 31/32' 13' 19/32' 3-67/8'punched hole 'Co nnEC"il'wire hale) Ren m f-1r—C� � N Nvn01e O rV MonNe HanNe m u, O 2-3 Air O® Air Intake O® Lb}ural C m N GAS LID VL'106351FLARE N m O® 5)l UNt S} GAS 3/8109527FLARE 7 LID f 1 Lo VL'(0635)FLARE GAS UNI A—GAS V2'(012.71FLARE � 1-11/32' 14-7/32' 1.FREE SPACE a o E d y 3-15/16'or more ° m n 0 0 0 3-15/16' or more13-25/32'or more Conduit plates 2.SERVICE SPACE E a t' Conduit connector Lock nut _V 3-15/16' Dr more SERVICE SPACE 13-25/32'or are 13-25/32'or more A& MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com Eta us FORM#MXZ-3C24NA2 for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc. SUBMITTAL 9,000 BTUIH WALL-MOUNTED INDOOR UNIT FORMULTI-ZONE Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL09NA GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button 1 Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: I ' Cooling Capacity',3 BTU/H 9,000 Heating Capacity2,3 BTU/H 10,900 Voltage,Phase,Frequency 208/230V,1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight Lbs.(kg) 26(11.5) Refrigerant Type R41 OA Piping Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6,35) Notes: 'Cooling(Indoor H Outdoor) °F 80 DB,67 WB//95 DB,75 WB Nominal Conditions 21-leating at 47°F(Indoor H Outdoor) °F 70 DB,60 WB//47 DB,43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: 09 Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo touchT"' RedLINKTm Wireless Controller ❑MHK2 Deluxe MA Remote Controller) ❑PAR-40MAAU Simple MA Controller) ❑PAC-YT53CRAU-J Touch MA Controller) ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interfacet ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01 HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1 CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711-110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑X85-003 Fascia Kit for MicroBlue Pump–mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without\notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 • MSZ-GL09NA Unit: inch 1/16x1 Oblong hole 1/16x13/I6 Oblong hole Insfallofion plafe 3-1/8 8'1/8 8 1/8 118 m 77 31-1/16 30-15/16 1/4 o m o �r1l - [2-1/8 -3/ 13-5/16 139/16 3/16 9-1/8 Indoor unit Air in all hole i 3 Insfallafion lafe N Pi in eh N 1-5/8 1-3/4 1-15/16,1 24-3/8 X15-1/8_ \0,(.in hose 4-3/I6c,; 2-5/lam 3/4 ,o � � Air ouf 4 3/ Insulation o1-3/8 0.1) G Liquid line of/4 19-11/16(Flared connection o1/4) E Gas line o3/816-15116 2-3/16 1-15/16-1 It JI 3/16 (Flared connection:0318(06109112 KBTUIH),o1/2(15 KBTUIH) Drain hose Insulation of-1/8 0.0 Connected part o5/8 0.13 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-333-4822 www.mehvac.com e I' FORM#MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT PUMP cI us SYSTEMS-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SUBMITTAL DATA: MSZ-GL12NA MITSUBISHI M-SERIES 12,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS Ar1k ELECTRIC Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL12NA i t GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: MSZ-GL12NA Cooling Capacity'.3 BTU/H 12,000 Heating Capacity2.3 BTU/H 14,400 Voltage,Phase,Frequency 2081230V, 1 phase,60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet . CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 45-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In.(mm) 33-1/2(850) Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight Lbs.(kg) 26(11.5) Refrigerant Type R41 OA Gas Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Notes: 'Cooling(indoor H Outdoor) T 80 DB,67 WB//95 DB,75 WB Nominal Conditions 2Heating at 47°F(Indoor H.Outdoor) T 70 DB,60 WB//47 DB,43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: Anti-allergy Enzyme Filter ❑MAC-408FT-E kumo touchTm RedLINKTm Wireless Controller ❑MHK2 Deluxe MA Remote Controller) ❑PAR-40MAAU Simple MA Controller) ❑PAC-YT53CRAU-J Touch MA Controller) ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interfacet ❑MAC-3341F-E Wireless Interface 2 ❑PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® ❑PAC-WHS01HC-E USNAP Interface ❑PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711-110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H ❑X85-003 Fascia Kit for MicroBlue Pump–mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3341F-E 2Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 • ` Unit: inch 1/16x1 Oblong hole 1/16x13/I6 Oblong hole Insfallafion late 3"1/8 8"118 8 1/8 118 31-1/16 30-15/16 1/4 CO cc n m o �_ 6-1/8 6-1/8 w 2-3/ 13-5/16 13-9/16 2-1/8 9 1/8 Air in al l hole 03 3116 Indoor unit fl �7 Installation Iafe Q � � LJ 'id M � 1-3/4 1-15/I6, 24-3/8 5 I/S,I � 1 1 5/8 `77 4-3/16 ' Drain hose 4-3/ 2-5/16 3/4 ■ �Q Air out n M _ Insulation 01-3/8 O.D 'a Liquid line o1/4 19-11/16(Flared connection o1/4) 'a Gas line o3/8 16-15/16 2-3/16 1-15/16 I 3/16 (Flared connection:o318(06109112 KBTUIH),o1/2(15 KBTUIH) —� Drain hose Insulation of-1/8 O.D Connected part o5/8 O.D 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ' FORM#MSZ-GL12NA FOR MXZ-C MULTI-ZONE HEAT PUMP CONUs SYSTEMS-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.