Loading...
HomeMy WebLinkAbout46702-Z S�FFO(+ r Town of Southold o� o��,, 1/14/2023 a y� i P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43764 Date: 1/14/2023 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1180 Smith Dr S, Southold SCTM#: 473889 Sec/Block/Lot: 76.-3-12.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/8/2020 pursuant to which Building Permit No. 46702 dated 8/17/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions and alterations, including covered entry,to existing accessory garage as applied for. The certificate is issued to Kessel,Helga N Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46702 5/16/2022 PLUMBERS CERTIFICATION DATED Aut or' a Signature �o�SUFFot,��oTOWN OF SOUTHOLD �y BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "may • ,� SOUTHOLD, NY os BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46702 Date: 8/17/2021 Permission is hereby granted to: Kessel, Helga 800 Golden Beach Blvd Venice, FL 34285 To: construct additions and alterations to existing accessory garage as applied for per DEC No Permit Necessary letter. At premises located at: 1180 Smith Dr S, Southold SCTM #473889 Sec/Block/Lot# 76.-3-12.1 Pursuant to application dated 12/8/2020 and approved by the Building Inspector. To expire on 2/1612023. Fees: ACCESSORY $167.20 CO-ACCESSORY BUILDING $50.00 Total: $217.20 Buil ' g n ec or pF SO(/r�,olo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(a-town.southold.nv.us Southold,NY 11971-0959 Q�yCOi+JNTY,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Kessel Helga N Trust Address: 1180 Smith Dr S city:Southold st: NY zip: 11971 Building Permit#: 46702 Section: 76 Block: 3 Lot: 12.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Ben Franklin Electric License No: 4211 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor X Hot Tub Addition Survey Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt 9 Ceiling Fixtures 5 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 2 CO2 Detectors Sub Panel 100A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 1 Switches 5 4'LED Exit Fixtures 11 Pump Other Equipment: Sub Panel 8 Circuit/ 3 Used Notes: Acc. Garage Inspector Signature: Date: May 16, 2022 S.Devlin-Cert Electrical Compliance Form o��OF SOGIyO Ll 0 S.AV JW fZ # # TOWN OF SOUTHOLD BUILDING DEPT. co 765-1802 INSPECTION _ [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE-& CHIMNEY ': [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION' [ ] FIRE RESISTANT PENETRATION :ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O REMARKS: 'A CGRP ot-<l ka f C47:1 110CLr DATE Z ll2 INSPECTOR OF SOGIyo� TO. N� 6(/( # # OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: -l' �. &7e.3Q'Lii I In �(Z IA//�/) 01 Q, d DATE Z INSPECTOR �— OF SOUIyOlo TOWN OF SOUTHOLD BUILDING DEPT. oourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING FINAL 6m9w [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 574�rPP �, a6 C .i F.�C1fL 6&9--r. F.;l7C/gTE AS v DATE S-zu INSPECTOR ✓� OE SOUTyolo TOWN OF SOUTHOLD BUILDING DEPT. `yComm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL -� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: i0, lu Aon DATE LO'L�/ INSPECTOR S' CHARLES M. THOMAS R.A., PLLC FEB 1 6 2021 ZOG LINCOLN STREET RIVERHEAD, NY I 1 901 (63 1 )727-7993 CDTHOMAS63 @AOL.COM Z/1 5/2O2 I Building Department Town of Southold Re: Kessel Residence SCTM # 1000-76-03-12.1 Amanda, Enclosed please find revised plans for the garage addition that we discussed. The client intends to leave the upper area of the garage unfinished and used only for storage. The stair is open to the garage area and no longer enclosed in a separate "foyer" area. This will give them more usable space to park cars. Thank you for your attention to this matter. Please contact me with any questions you have. 0 Very your .ATHOMAS, R.A., ARL��S / 1 D E CEHE CHARLES M. THOMAS R.A., PLLC JUN 2 12022 206 LINCOLN STREET TOWN BUILDING OF D PT RIVERHEAD, NY 1 1 901 HOLD (63 1 )702-35 1 9 / /{ ODTHOMAS63 @AOL.COM W�V2- JUNE 20, 2022 Building Department Town of Southold Re: Kessel Residence 1180 Smith Drive South, Southold SCTM#1000-76-3-12.1 Dear Sir/Madam: This letter shall serve to certify that no fire separation is required between a detached garage and unfinished storage above. As per table R302.6 "Dwelling- Garage Siparation" from the 2020 Residential Code of New York State, 5/8" sheet rock is only needed for habitable rooms above the garage. Since the proposed room over the garage is to be unfinished with open framing for storage only, 5/8 sheet rock on walls and ceiling is not needed. Thank you for your attention to this matter. Please contact me with any questions you have. Very tr lyV-- CHARLES M. TMAS, R.A., A�C . Y CHARLES M. THOMAS R.A., PLLC ® II 206 LINCOLN STREET DEL 2f 2077 RIVERHEAD, NY 1 1 901 (5 1 6) 702-3519 BUILDING DEP` ODTHOMAS63 @AOL.COM `IOWHOFSOifl1-IOLD DECEMBER 23, 2022 Building Department Town of Southold Re: Kessel Residence 1180 Smith Drive South, Southold SCTM#1000-76-3-12.1 Dear Sir/Madam: This letter shall serve to certify that I was retained to inspect the above referenced detached garage throughout construction. I can attest that I have completed the following inspections and all elements have been installed/constructed in a manner than conforms to my plans and specifications and the 2020 NYS Residential Code: • Poured concrete footing • Footing keyway • Foundation wall prior to backfill • Framing and strapping Thank you for your attention to this matter. Please contact me with any questions you have. Very truly yours, CHARLES M. THOMAS, R.A., O T ' FIELD:INSPECTION REP. ,E DATE 1777 FOUNDATION(1ST) C3 H FOUTDATION`(2ND) ROUGH FR.AM PLUMBING: 1 INSULATION.PER N.Y. :. : ' ::.: ER ..„.. . ; STATETNGY 6015E s Z ls—f`�-d�7r•.: 'ST S FsAA�LS 05, RAF='OV(e6 Ct FINAL. 4Mr, f aDDiroivaa :ca:... . ,a e '-3 o. 5-��-aa� TOWN OF SOUTHOLD—BUILDING DEPARTMENT N. Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov 6 V For Office Use Only Date Received qo PERMIT NO. Building Inspector. J I \JV Applications and forms must be filled out in their entirety. Incomplete applications J % 2020 will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. 7 7 M-1— APPLICATION'FOR BUIL,DI'N'G PERMIT ate: 7 OWNER(S),OP PROPERTY: Name: LW-L N F-9 ESS E L- Tax Map#:SCTM#1000- Physical Address: 1-T Hb)Z\V-E 5,0 u-Vk sov,"qotj 01 Phone#: � Email: Iq 6�CknClii A eS!S�k 636 64-S-- 30II . 1 � I C 0 M Mailing Address: SRAIL ftS Pr FDV-0 CONTACT PERSON,:,, -Name: —Mailing Address: 0,7 Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: R P,Lf S, 7 W fA Mailing Address: 1P. o. .9w 8 Tea YA eS .0 1 Phone#: Email: �33 CONTRACTOR INFORMATION:. Name: -T-6wY V_a5_Mr4ro_K_ Mailing Address: WA_r 6,9-1 etc) Phone#: Email: 2 Z CP r lytCO-t - 'DESCRIPTION IF PROPOSED CONSTRUCTION ONewStructure *ddition Alteration EIRepair ElDemolition Estimated Cost of Project: Elother Will the lot be re-graded? Dyes E]No 6;,-1ki'l`l`e' xcess fill be removed from premises? E]Yes ONO PROPERTY INFORMATION Existing use of property: Or Intended use of property: Date of Purchase:- Name of Former Owner: 2-0 2-C Zone or use district in which premises is situated: Ar&e're any covenants and restrictions with respect to this, Foperty? Dyes ONO IF YES, PROVIDE A COPY. K heck Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by er 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): L& ti 57F ❑Authorized Agent Owner Signature of Applicant: I } Date: 1 ( 1 t ?�Z71) STATE OF NEW YORK) COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor Agent;.: orpor,ate Officer,etc.) of said owner or owners, and is duly authorized to perform';or.Ma`tr'e::performed the said work and to make and file this application;that all statements contained in this application are-.'true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of4 t✓�V"'t�`i1x�t 20 ( U h A icoft elio N t ryP blit Notary Public State of New York County of Suffolk REG#01 MU6090387 PROPERTY OWNER AUTHORIZATION Expires April 14,20 (Where the applicant is not the owner) 1,^f'1� A- residing at / 1 D� 15-7 1y� c k �P" do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. O�ner's Signature Date RE, L&A `N j�jje �E:5,�5 E L__ Print Owner's Name NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits,Region 1 SUNY®Stony Brook,50 Circle Road,Stony Brook,NY 11790 P:(631)444-03651 F:(631)4440360 www.dec.ny.gov NO PERMIT NECESSARY August 9, 2021 Helga Kessel 1180 Smith Dr. S. Southold, N.Y. 11971 Re: UPA#1-4738-00743/00004 Facility: 1180 Smith Dr. S., N.Y. SCTM# 1000-76-3-12.1 Dear Helga Kessel: The Department of Environmental Conservation (DEC) has completed a review of your proposal to construct a 132 square foot addition to your detached garage. Based on the information you submitted, the survey prepared by Nathan Taft Corwin III, LLS last revised 6/10/2021, this department has determined that the project is listed in the Tidal Wetlands Land Use Regulations (6NYCRR Part 661.5 (b) (#50)) as a use not requiring a permit. All work is located greater than 75' from the tidal wetland boundary, and the lot coverage is less than 20%. Therefore, no permit is required under the Tidal Wetlands Act (Article 25) of the Environmental Conservation Law. (DEP ARNO) Be advised, any additional work or modification to the project as described, may require DEC authorization (e.g. changing the footprint of your home, upgrading the sanitary system, etc.). Please contact this office if such activities are contemplated. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. ;S'Anry, • Sherri Aicher Deputy Regional Permit Administrator cc: JMO Environmental Consulting, BMHP, File NEWYORK Departmental STATL'O/' �n„rte EnvlranmQntal Conservatlon ILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o r �' •EB O 7 ���? T r all Annex - 54375 Main Road - PO Box 1179 � x BUILDING DEPT. Southold, New York 11971-0959 QWN OF SOUTHOLD Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr _southoldtownny.gov - sea nde-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/3/22 Company Name: B.F.E. Inc Electrician's Name: Ben Franklin Electrical License No.: ME 4211 Elec. email: bfe562@gmail.com Elec. Phone No: 631-878-2544 0 I request an email copy of Certificate of Compliance Elec. Address.: HU box 1294 Center Moriches NY 11934 JOB SITE INFORMATION (All Information Required) Name: Kessel Add "" "1,18'0:Smifh dr Southold Cross Street: Phone No.: +++++++++++++++ Bldg.P.P-et4'6702email: ++++++++++++++++ Tax Map District: 1000 Section: Block: Lot: BRIEF.hi,.DE �.a.u,R. I'PinTION,Mt-S*-,vna7afvO.*.mF. a dt`aUaDJE aQaAAf, RE FOOTAGE (Please Print Clearly): 0 n `ea" G.u,l+, v:'.•;., . vr P4, Square Fo�tag,, -_, .:1,75,y . Circle All That Apply: >. Is job ready for inspection?: R1*'YE" t7;E] NO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: .(All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 72 M H Frame M Pole Work done on Service? MY MN Additional Information: PAYMENT DUE WITH APPLICATION 2 XCP e �OSUFF (;, nV E 'B ILDING DEPARTMENT- Electrical Inspector O t TOWN OF SOUTHOLD o� EB 0 7 2022 T all Annex - 54375 Main Road - PO Box 1179 cn x' BUILDING DEPT. Southold, New York 11971-0959 � b1:! i Off SOUTHOLDy,� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cD-southoldtownny.gov — seand(cD-southoldtowriny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/3/22 Company Name: B.F.E. Inc Electrician's Name: Ben Franklin Electrical License No.: ME 4211 Elec. email: bfe562@gmail.com Elec. Phone No: 631-878-2544 0 I request an email copy of Certificate of Compliance Elec. Address.: PU ox 1294 Center Moriches NY 11934 JOB SITE INFORMATION (All Information Required) Name: Kessel Address: 1180 Smith dr Southold Cross Street: Terry PL Phone No.: +++++++++++++++ __Bld r� ; '6702 '_ _ �Ip 0-a..._. email:.+++--... - +++++++ Tax Map District: 1000 Section: Block: Lot: /� ryV�ly:Q`°Ty+rJJ I FR K f�:. FOOTAGE (Please Print Clearly): .A.i.tlifciW \ 1 R. fl• .P.1 ;/.,...«i; y -, J^� $90.00 Square Footage: 175' Circle All That Apply: Is job ready for inspection?: Fs/1YES ❑ NO ❑✓ Rough In Final Is Do you need a Temp Certificate?: ❑ YES FV-� NO Issued On Temp Information: .(All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Servicer-1 Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �k�) hV*1 PERMIT Address:- Switches ` Outlets GFI's Surface Sconces H H's f I UC Lts Fans �.. . . ...... . .. ... .......:. ,. .Fridge �.. ... .. , .. ,.. ..HW . _ .. . ..,.. .. .. .. . . Exhaust Oven W/D Smokes DW Mini : Carbon _. :1Vlicro.. .,: .:::. _ .-. . _Generator.:.. .. .. ...;• Tra Combo Cooktop nsfer::. . � a AC. AH. Hood Service Ampsa' H"ve Used: . Special:. Comments: { CGenerated by REScheck-Web Software �(J Compliance Certificate Project Phillips Residence Energy Code: 2018 IECC Location: Mattituck, New York Construction Type: Single-family Project Type: Addition Climate Zone: 4 (5331 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 165 Dogwood Lane Peter Phillips Chuck Thomas Mattituck, NY P.O. Box 877 jamesport, NY 11947 516-702-3519 ,Compliance: Passes using UA trade-off Compliance: 0.3%Better Than Code Maximum UA: 383 Your UA: 382 Maximum SHGC: 0.40 Your SHGC: 0.30 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Ceiling: Flat Ceiling or Scissor Truss 2,194 38.0 0.0 0.030 0.026 66 57 Wall:Wood Frame, 16" o.c. 2,194 21.0 0.1 0.057 0.060 91 96 Door: Solid Door(under 50%glazing) 36 0.350 0.320 13 12 Door 1: Glass Door(over 50%glazing) 109 0.300 0.320 33 35 SHGC: 0.30 Door 2: Glass Door(over 50%glazing) 216 0.300 0.320 65 69 SHGC: 0.30 Window:Vinyl Frame 230 0.300 0.320 69 74 SHGC: 0.30 Crawl: Solid Concrete or Masonry Wall height:4.0' 823 0.0 11.0 0.073 0.065 45 40 Depth below grade: 3.0' Insulation depth: 4.0' Compliance Statement: The proposed—buildii g design described here is con ' t with the building plans,specifications,and other calculations submitted with the p�m1;app'icatlon-zkThe proposed building as b n desi to meet the 2018 IECC requirements in REScheck Version : RESche kP �e gand�to_compj�.wAh the mandatory re uire nts lis d i he REScheck Inspection Che klist. Name TitleSl"eVre Date Project Title: Phillips Residence,>-, h Report date: 08/23/21 Data filename: Pagel of 9 t REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified: # Pre-Inspection/Plan Review Complies? Comments%Assumptions &Req.ID, Value. Value, 103.1, ,Construction drawings and j❑Complies 103.2 documentation demonstrate 113Does Not [PR1]1 :energy code compliance for the I :building envelope.Thermal ❑Not Observable lenvelope represented on (. I❑Not Applicable ;construction documents. I 103.1, ;Construction drawings and ❑Complies 103.2, ;documentation demonstrate ? ❑Does Not 403.7 ;energy code compliance for I [PR3]1 ;lighting and mechanical systems. i 3❑Not Observable , (Systems serving multiple ❑Not Applicable ;dwelling units must demonstrate t ;compliance with the IECC Commercial Provisions. 302.1, !Heating and cooling equipment is; Heating: Heating: ;❑Complies 403.7 (sized per ACCA Manual S based Btu/hr Btu/hr ;❑Does Not [PR2]2 Ion loads calculated per ACCA Cooling: Cooling: :❑Not Observable ' Manual j or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable y � ! Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 2 of 9 section, Plans Yer'ified, Field.Verified # Foundation:inspect'ion Complies? " Comments/Assumptions &Req:ID . Value , Value:. 402.2.11 ;Unvented crawl space wall R- R- ;❑Complies ;See the Envelope Assemblies [FO7]1 !insulation R-value. :❑Does Not ;table for values. R- � R- , ❑Not Observable ❑Not Applicable 303.2 ;Unvented crawl space wall �❑Complies [FO8]1 hnsulation installed per ❑Does Not !manufacturer's instructions. ❑Not Observable f❑Not Applicable 402.2.11 ;Unvented crawl space continuous I❑Complies [FO9]1 (vapor retarder installed over ❑Does Not exposed earth,joints overlapped ;by 6 in.and sealed,extending at ❑Not Observable 1 I least 6 in. up and attached to the ;[]Not Applicable ;wall. 402.2.11 I Unvented crawl space wall in. in. ;❑Complies ;See the Envelope Assemblies [FO10]1 hnsulation depth of burial orj ;❑Does Not :table for values. distance from top of wall. ;❑Not Observable ❑Not Applicable 303.2.1 iA protective covering is installed ` ., I❑Complies [F011]z, Ito protect exposed exterior e ❑Does Not }insulation and extends a u•. . ? []Not Observable 1 i minimum of 6 in. below grade. • ; ; - J❑Not Applicable ; 403:9 Snow-and ice-melting system ❑Complies [FO12]2controls installed. . j ;❑Does Not tg) € J❑Not Observable s ]❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/:Rough-In-Inspection Complies? Comments/Assumptions` &"Req.ID, Value Value'. , 402.1.1, ;Door U-factor. ; U- ; U- ;❑Complies ;see the Envelope Assemblies 402.3.4 :❑Does Not ;table for values. [FR1]1 v ' ; ;❑Not Observable ❑Not Applicable 402.1.1, ;Glazing LI-factor(area-weighted U- U- ;[]Complies ;See the Envelope Assemblies 402.3.1, ;average). !❑Does Not ;table for values. 402.3.3, 402.5 ; ! :❑Not Observable [FR2]1 ;❑Not Applicable 303.1.3 i U-factors of fenestration products ❑Complies [FR4]1 :are determined in accordance ❑Does Not j +with the NFRC test procedure or ou ,taken from the default table. )❑Not Observable , ❑Not Applicable ; 402.4.1.1 ;Air barrier and thermal barrier i ❑Complies ; [FR23]1 ;installed per manufacturer's �_ ; `'° ❑Does Not instructions. lJ ; ❑Not Observable ❑Not Applicable 402.4.3 ;Fenestration that is not site built [ ; i❑Complies [FR20]1 ;is listed and labeled as meeting : s❑Does Not j AAMA/WDMA/CSA 101/I.S.2/A440 S" I or has infiltration rates per NFRC ; ;[]Not Observable ; 1400 that do not exceed code "' :PNot Applicable ; ;limits. 402.4:5 {IC-rated recessed lighting fixtures;'. _ ❑Complies [FR16]? sealed at housing/interior finish ' ;❑Does Not and labeled to indicate:52.0 cfm I leakage at 75 Pa k. '!!❑Not Observable ; E • j❑Not Applicable ; 403.3.1 ;Supply and return ducts in attics 4 " E❑Complies [FR12]1 insulated >= R-8 where duct is [ t ❑Does Not j >= 3 inches in diameter and >_ ` R-6 where< 3 inches.Supply and} ❑Not Observable 3❑Not A licable return ducts in other portions of i pp ! ;the building insulated >= R-6 for !)diameter>=3 inches and R-4.2 !for< 3 inches in diameter. 4 403.3.2 !Ducts,air handlers and filter ` ❑Complies [FR13]1 !boxes are sealed with [ 1, ❑Does Not ! !joints/seams compliant with z ! j J p t JONot Observable ; ;International Mechanical Code or ; ;International Residential Code,ask ❑Not Applicable ; ;applicable. ' 403.3.5 iBuilding cavities are not used as ❑Complies ; [FR15]3 'ducts or plenums. ❑Does Not , j { }❑Not Observable ; : J❑Not Applicable 403.4 :HVAC piping conveying fluids R- 1 R- ;❑Complies [FR17]2 f above 105°F or chilled fluids ! ! !❑Does Not i�• !below 55 IF are insulated to 2--R- !below ! ! 3 ! ;❑Not Observable f 1❑Not Applicable 403.4.1 ;Protection of insulation on HVAC ' ' ;❑Complies [FR24]1 ;piping. f❑Does Not ; }❑Not Observable ; J❑Not Applicable 403.5.3 . •'Hot water pipes are insulated to R- R- ;❑Complies [FR18]2� zR-3. ;❑Does Not ;❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 1,3 1 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 4 of 9 Section Plans Verified Field Verified' #, Framing/Rough-In Inspection , :Complies? Comments/Assumptions. & Req.ID Value Value 403.6 Automatic or gravity dampers are; f j❑Complies [FR19]2 i installed on all outdoor air J❑Does Not !intakes and exhausts. (. J❑Not Observable Y I .j❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3_ Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 5 of 9 Section Plans Verified - 303.1 Insulation Inspection Value Field Verified Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 for the installed R-values f ❑Does Not tBj i provided. ❑Not Observable J❑Not Applicable 402.1.1, ;Wall insulation R-value. If this is a;, R- ; R- ;❑Complies ;See the Envelope Assemblies 402.2.5, !mass wall with at least 1/2 of the ,0 Wood ;❑ Wood ;❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall ;❑ Mass ❑ Mass :❑Not Observable [IN3]1 ;exterior,the exterior insulation j !requirement applies(FR10). ❑ Steel 1❑ Steel :❑Not Applicable F , 303.2 ;Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ; ❑Does Not J❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 6 of 9 section" Plans Verified Field Verified . # Final Inspection Provisions Complies? Comments%Assumptions &.Req.ID. Value' Value' :. 402.1.1, !Ceiling insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, w ❑ Wood ❑ Wood ,❑Does Not table for values. 402.2.2, { ❑ Steel ❑ Steel :❑Not Observable ; 402.2.6 [Fill' ;❑Not Applicable 303.1.1.1,;Ceiling insulation installed per t`t ❑Complies 303.2 manufacturer's instructions. t ? - ❑Does Not [FI2]1 ;Blown insulation marked every ' - 1300 ft2. _ ❑Not Observable i❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2j insulation include baffle adjacent !- ❑Does Not ,to soffit and eave vents that ;extends over insulation. ][_-]Not Observable 1❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- I❑Complies [FI3]1 (insulation >_R-value of the ;❑Does Not adjacent assembly. ❑Not Observable ' ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ; ACH 50 = ACH 50 = I❑Complies [FI17]1 iach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 ;,Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [FI27]1 determine air leakage with ft� ftz 1❑Does Not ;either: Rough-in test:Total ;leakage measured with a j UNot Observable I pressure differential of 0.1 inch ;❑Not Applicable ; lw.g. across the system including ;the manufacturer's air handler !enclosure if installed at time of I i ;test. Postconstruction test:Total ;leakage measured with a ; pressure differential of 0.1 inch ;w.g.across the entire system including the manufacturer's air ; I !handler enclosure. # 403.3.4 ;Duct tightness test result of<=4 ; cfm/100 cfm/100 ;❑Complies [FI411 !cfm/100 ft2 across the system or ft2 ft� ❑Does Not !<=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in :❑Not Observable Itests,verification may need to ! ;❑Not Applicable ;occur during Framing Inspection. ! 403.3.2.1 ;Air handler leakage designated j❑Complies ! [FI24]1 ;by manufacturer at<=2%of ❑Does Not !design airflow. i ❑Not Observable ! ❑Not Applicable 403:1:1 ;Programmable thermostats (❑Complies [F[9]2 installed for control of primary ` _ ]EIDoes Nat heating and cooling systems and )j ❑Not Observable initially set by manufacturer to ) jcode specifications. J❑Not Applicable ; 403:1.2 ,;Heat pump thermostat installed ❑Complies [FI1Q]2 ion heat pumps. j t❑Does Not ❑Not Observable ; I [ _ : ❑Not Applicable , 403.5.1 ICirculating service hot water 4 ?❑Complies [FI11]2- #systems have automatic or c (. !❑Does Not ;accessible manual controls. t ❑Not Observable i 3❑Not Applicable ; 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3;1 Low impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 7 of 9 Section ReqPlans Verified Field Verified• , Final.Inspection ProvisionsComplies?" Comments/Assumptions" .ID Value' Value 403.6.1- }All mechanical ventilation system '. JDComplies [FI25]2 {fans not part of tested and listed ❑Does Not I HVAC equipment meet efficacy i and air flow limits per Table !❑Not Observable 3 R403.6.1. i❑Not Applicable 403.2 S Hot water boilers supplying heat ; ❑Complies [F12611 )through one-or two-pipe heating ❑Does Not ; 'systems have outdoor setback control to lower boiler water ❑Nat Observable , ]temperature based on outdoor i❑Not Applicable itemperature. 403.5.1.1 j Heated water circulation systems t .". ?❑Complies [FI28]2 i have a circulation pump.The S ❑Does Not ;system return pipe is a dedicated F $return pipe or a cold water supply,' ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system ;pumps start the pump with signal g ;for hot water demand within the 'occupancy.Controls automatically turn off the pump when water is in circulation loop ) ; ;is at set-point temperature and no demand for hot water exists. 403.5:1.2 'Electric heat trace systems I I❑Complies [F129]2, ;comply with IEEE 515.1 or UL i❑Does Not i515.Controls automatically I adjust the energy input to the ` ,�❑Not Observable heat tracing to maintain the 1❑Not Applicable ; desired water temperature in the S. piping. 4 403.5.2 Demand recirculation water - I❑Complies ; [FI30l2 systems have controls that ❑Does Not ,,manage operation of the pump g ',and limit the temperature of the ❑Not Observable ;water entering the cold water ❑Not Applicable piping to<= 1049F. [' r 403.5.4Drain water heat recovery units ` :;❑Complies [F[31]2 tested in accordance with CSA ❑Does Not I B55.1. Potable water-side 4 pressure lass of drain water heat g ❑Not Observable recovery units <3 psi for '❑Not Applicable individual units connected to one _ or two showers. Potable water- side pressure loss of drain water ,= (heat recovery units < 2 psi for I~ individual units connected to ithree or more showers. f 404.1 190%or more of permanent i ❑Complies [FI6]1 fixtures have high efficacy lamps.s. ❑Does Not g t❑Not Observable €; ❑Not Applicable 404.1.1 ;Fuel gas lighting systems have ; 111Complies [F[23]3 {no continuous pilot light. I ❑Does Not ;A. ❑Not Observable i •f❑Not Applicable 401.3 ;Compliance certificate posted. []Complies [F17]2 ❑Does Not ❑Not Observable ; ,;❑Not Applicable ; 1 High Impact(Tier 1) 2: Medium Impact(Tier 2) 3; 1 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 8 of 9 Section Plans Verified- Field Verified, # Final Inspection ProvisionsComplies? Comments/Assumptions &Req.ID Value' Value. 303.3 ;Manufacturer manuals for (❑complies [f118]3 ;mechanical and water heating ❑Does Not ;systems have been provided. ❑Not Observable , IONot Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Phillips Residence Report date: 08/23/21 Data filename: Page 9 of 9 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.06 Below-Grade Wall 11.00 Floor 0.00 Ceiling / Roof 38.03 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.30 0.30 Door 0.30 0.30 Cooling!Heating & Heating System: Cooling System: Water Heater: Name: Date: Comments SURVEY OF LOTS 49 & 50 MAP OF GOOSE NECK SOUTIA FILE No. 1663 FILED NOVEMBER 22, 1948 DI I�' . : . SITUA TED A T smBA V a Y IEW TOWN OF SOUTHOLD 14 SUFFOLK COUNTY, NEW YORK •.-a. � d - � 111#19 • ., •" _ :107 t2 S.C. TAX No. 1000-76-03- 12.1 :. ;' •• a•. ��++w'►^�— ' � SCALE 1 "=20' 30'0p" E NOVEMBER 22, 2004 o. hI ap• cp ` AUGUST 14, 2007 STAKE OUT GARAGE FOUNDATION & SET 2 STAKES ON WEST PROPERTY UNE SEPTEMBER 18, 2007 FOUNDATION LOCATION JULY 28, 2008 FINAL SURVEY FOR GARAGE Ac ADDITIONS 178,99 � E 4 �yy� 0- APRIL 16, 2020 UPDATE SURVEY 70 .Oo• E c�' �a ��� / / !L AREA = 26,730 sq. ft. go'3o 0• a r N ^ .• m `; (TO TIE UNE) 0.614 ac. 1.�y 4(V Vz i • 'O gam`\ CERTIFIED TO: Com • 4. . • >t i HELGA NETTE KESSEL FIDELITY NATIONAL TITLE INSURANCE COMPANY oti/ Grp S�" o Cl NCO � r ! ^V r 71 9 �adv- 6 1p r N � k Rpt 3 ' •�. ��.L 1 '�, ,�' � mol. �•�.9 3�. E SNOIL L r—`L 3O . W ��R PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED / BY THE L.I.A.L.S. AND APPROVED AND ADOPTED —�— FOR SUCH USE BY THE NEW YORK STATE LAND TnLE ASSOCIATION. �0 1 10e 39 10'W ` S $132 72• t , �Y N.Y.S. Lic. No. 50467 4 \ 4 4 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF S \ 1 4athan Taft Corwin 111 EDcnON 7209 OF THE "�" " A� EDUCATION T11W. tnE� COPIES of This SURVEY MAP NOT BEARING LandSurveyor EMBOOSSSTO BE AEDDv •SAUD TRUE � E CONSEAL SIDERED I r 78.36,0'� SEAWARD �� •�• CERTIFICATIONS INDICATED HEREON SHALL RUN �/ WRSMCETATApy SALT ONLY TO THE PERSON FOR WHOM THE SURVEY N S$• 4'3 O" w Successor To: Stanley J. Isoksen, Jr. L.S. IS PREPARED. AND ON HIS BEHALF TO THE Joseph A. Ingegno L.S. TITLE COMPANY, GOVERNMENTAL AGENCY AND Dock Ton+EASSIGN�OTHTHE°LENDIING" AND i STI- Coos37.32' Title Surveys — Subdivisions — Site Pians — Construction Layout TUTION. CERTIFlCATK)r1SARE NOT TRANSFERABLE. � PHONE (631)727-2090 Fax (631)727-1727 OFFICES LOC4T7=D AT MAILING ADDRESS THE EXISTENCE OF RIGHTS OF WAY 1586 Alain Road P.O. Box 16 AND/OR EASEMENTS OF RECORD. IF Jamesport, New York 11947 Jamesport, New York 11947 ANY. NOT SHOWN ARE NOT GUARANTEED. 40-093 O ' ad J�p+ ~ W.'W'rr I IC ± 'A 7l i 1 ^h Gr APPROVED AS NOTED = p ARCH ITECT C.Ah�F DATE: B,P.# FEE: BY: NOTIFY BUILDING DEPARTMENT AT REVISIONS D E S C R I P T I O N 765-1802 8 AM TO 4 PM FOR THE 2/12/21 FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED Mill It Iiii 11 11111 FOR POURED CCNCRETE - 2. ROUGH - FRAMING & PLUMBING EXTEND EXISTING 0 F I I I 1 12 3 INSULATION I 4 FINAL - CONSTRUCTION MUST EXISTING ASPHALT BE COMPLETE FOP r ROOF SHINGLES 0• ALL CONSTRUCTION SHALL MEET THE 1 5-10" PLATE HEIGHT I I 1 11 L I I I I I I I 1 1 5'-10" PLATE HEIGHT REQUIREMENTS OF THE CODES OF NEW —_ — T.O. WINDOWS YORK STATE. NOT RESPONSIBLE FOR — 12 � DESIGN OR CONSTRUCTION ERRORS. 10.5 I COMPLY WITH ALL CODES OF � N NEW YORK STATE & TOWN CODES 1" X 8" FASCIA - EXISTING ASPHAL? U AP727B "WOVER T.O. SECOND FLOOR N AS REQUIRED AND CONDITIONS OF ROOF SHINGLES _ T 1" X 8" FASCIA T.O. SECOND FLOOR o� — - FRIEZE - W/1"X2" OVER 6 = 10'-0" PLATE HEIGHT y I ' Lv'70J1V19tN'�INrgQARD 10'-0" PLATE HEIGHT 6" FRIEZE N T.O. WINDOWS T.O. WINDOWS -- -� 7 N.Y.S.DEC b 5/4"x4" WINDOW / \ 5/4"x4" WINDOW o OCC�1PAIi'CY OR & DOOR SURROUNDS —� & DOOR SURROUNDS N �j ❑ ❑ ❑ ❑ ❑ L__❑ ❑ ❑ ❑ ❑ (TYPI C AL) (TYPI CAL) � _-- I USE IS UNLAWFUL _ � � PROPOSED CEDAR El EJ Ll L Ll L E[A❑ ❑ � WITHOUT CERTIFICATE SHINGLES EXISTING CEDAR — DDEAEAD LEED ❑ ED 11 _ OF OCCUPANCY T.O. FOUNDATION WALL -TO MATCH EXISTING SHINGLES T.O. FOUNDATION WALL 9070 O.H. DOOR 9070 O.H. DOOR ui 5 RETAIN STORM WATER RUNOFF TOWN OF SOUTHOLD, NY, ACCESSORY BUILDING CODE: I I M PURSUANT TO CHAPTER 236 C. SUCH BUILDINGS SHALL NOT EXCEED 660 SQUARE FEET ON LOTS CONTAINING UP TO 20,000 SQUARE OF THE TOWN CODE. O FEET AND SHALL NOT EXCEED 750 SQUARE FEET ON LOTS 20.000 SQUARE FEET TO 60.000 SQUARE /11 ateriorligh :fig - ON LOTS OVER 60,000 SQUARE FEET, NO ACCESSORY BUILDING SHALL EXCEED 3% OF THE TOTAL 0 SIZE OF THE PARCEL. �'ei'4��ICd,replaC '� OT W D. DORMERS ARE PERMITTED ON ACCESSORY BUILDINGS UP TO 40% OF THE ROOF WIDTH. THIS ELECTRICAL p to Chapter 17 III W > RESTRICTION SHALL NOT APPLY TO BUILDINGS RECEIVING A CERTIFICATE OF APPROPRIATENESS FROM THE INISPECTION REQUIRF-D to C .co orm LLJ TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION PURSUANT TO CHAPTER 170 OF THE TOWN 04"the Town Cc jC CODE. U W 0 � z E F R O N T E L E V A T 1 0 N E SIDE ELEVA T 1 0 N W I 3 SCALE: 1 4" = 1'--0" 1 SCALE: 1/4" = 1'-0" / LLD 0 J U� --J 0 W 0 I TYPICAL ROOF CONSTRUCTION (� EXISTING ASPHALT ROOF SHINGLES r n ON 30# BUILDING PAPER ON 3/4" PLYWOOD DECKING. V ♦ D 2"X10" ROOF RAFTERS 0 16" O.C. _ ( 0 __ _ _ �ExrEND ExlsrlNc of a4 TYPICAL CEILING CONSTRUCTION � \ ®4 W � ri EXISTING ASPHALT 2" X 8" CEILING JOISTS 0 16" O.C. / \ 3 ROOF SHINGLES EXIS NG "X8" CLG. JOI " )C. r 1 - - - EXISTING CEDAR \ SHINGLES / \ 8'-0" PLATE HEIGHT _ 12 / / EXISTING �\ \ T.O. WINDOWS lAt ATTI C \ F REMAIN UNFINISHED OPENFRAMING \ \ \ TYPICAL FLOOR CONSTRUCTION 1" X 8" FASCIA 12 a W/1"x2" OVER EXISTING 11 j" 560 TJI FLOOR JOISTS 0 16"O.C. \ 10.5 EXISTING ASPHALT t. 1 11 11 ROOF SHINGLES L6" FRIEZE _ T.O. SECOND FLOOR EXISTING 11 �" TJI 560 SERIES JOIST 116" OC. Z .I ___ ______ 10'-0" PLATE HEIGHT �- T.O. WINDOWS �J TYPICAL WALL CONSTRUCTION I EXISTING CEDAR SHINGLES ON 15# BUILDING ON 5/8" EXISTING 7 DH2s2 PLYWOOD SHEATHING ON 2"4" WD. STUDS 0 16" O.C. GARAGE o co 14 Charles M . Thomas a r c h i t e c t EXISTING CEDAR EXISTING CEDAR SHINGLES SHINGLES EXISTING PO BOX 811 JAMESPORT NY 11947 (631) 721-7993 EXISTING 4" POURED CONCRETESLAB T.O. FOUNDATION WALL GRADE o PROJECT EXISTING 8" P.C. FOUNDATION WALL z ON 8"x16" P.C. FOOTING W/(3) ##4 BARS CONTINUOUS E REAR ELEVATION E SIDE ELEVATION s SECTION PROPOSED ELEVATIONS 2 SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" 1 SCALE: 1/49' DATE: 10/20/2( PROJECT No. DRAWING BY. MC CHK BY. DWG No. W-FO-0--firl THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IPJ WHOLE OR IN PART, IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIC EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. f fi„ MM RY's ycn �+ ' 32'-0" ADDITIO EXISTING �2,� ..� :. = � , LINE OF ROOF OVERHANG — — — — — — — — — 2'_4" 4'_0" — — — — — — — — — — — — — — — — — — — — — — — — pti ARCHITECT IL NE OF DORMER ABOVE— 7'-b 24'-0" I I � � I( I I " P.C. FOUNDATION WALL EXISTING 8" P.C. FOUNDATION WALL 8' 8" NEW 8ON 8"x16" P.C. FOOTING ON 8"x16" P.C. FOOTING 8" REVISIONS DESCRIPT ION I I 21221 I W/(3) #4 BARS CONTINUOUS W/(3) #4 BARS CONTINUOUS ( I / / co w o I OATco QslIORAGE w =I =I z Lo I I I I 1 1 o I ( I ( I DROP EXISTING 2'-4" a > F-F I FOUNDATION WALL TO cn V)� I I BELOW EXISTING SLAB �� EXISTING X N o w ( NEW SLAB TO MATCH U) 0IIII 8 0 x I � I I EXISTING z GARAGE _ � Wim= TOP OF SLAB L. — — I w UNEXCAVATED I I UNEXCAVATED Ir Of ELEVATION + 7.4' w o c�w ® M ( ) M O I > I 4" POURED CONCRETE o I zo m 3 w W p I _ _ N o 0 o SLAB OVER 6 MIL. EXISTING 4" SOURED CONCRETE SLAB o Z p W N w O,Ap (�O o_Z H a p I I POLYETHLENE VAPOR I REINFORCED W/ 6X6, 10/10 W.W.M. ON I I a I I X Z W g/e" TYPE 'X' SHEETROCK ZIw a I o I I BARRIER ON WELL I PROPOSED FOUNDATION COMPACTED EARTH I N UP w ALL WALLS AND CEILING F= — — CV (V (7 COMPACTED POROUS WALL ( N X U- I IIII o 3 x x EXISTING I p I I FILL (TYPICAL) Of La Ldo U) W w WINDOW I z 1i1 0 i � W TO J I L - - - -1 ( I I REMAIN I 0N LINE OF EXIS NG In PARTITION WALLS II II I DROP FOUNDATION WALL m TO BE REMO D TO MEET SLAB 0 II (TYPICAL) I II II I III I I I UNEXCAVATED I CONTINUOUS FOOTING v'Ji o Iw W >_ II II II II I I 4" POURED CONCRETE I ? SLAB OVER 6 MIL. =O INFILL EXISTING = Lv ~ II II II II I POLYETHLENE VAPOR- DROPPED (0 I Z I I BARRIER ON WELL „I 00 o w \ II II II I COMPACTED POROUSr I FOUNDATION WALL FILL DROPPED FOUNDATION WALL TO MEET SLAB CONTINUOUS FOOTING LINE I1—OFl DORMEf�I —ABOVE — II 3070 EXISTING (2) 11i" ML FLUSH —TI EXISTING (2) 111" ML FLUSH I I L --I 2 11�" ML HEADER I L - - - - - - - - - - - — — — — — — — — — — — 4'-0" 9'-0" 2'-0" 9'-0" 4'-0" E EXISTING WALL LINE OF ROOF OVERHANG TO REMAIN O LL (TYPICAL) 6'-4" 28'-0" O ADDITION EXISTING Ld A6'-4" 28'-0" ui >_ DDITION EXISTING W Q 34'-4" TOWN OF SOUTHOLD, NY, ACCESSORY BUILDING CODE f n3: C. SUCH BUILDINGS SHALL NOT EXCEED 660 SQUARE v ' I , I FEET ON LOTS CONTAINING UP TO 20,000 SQUARE LTJ FEET AND SHALL NOT EXCEED 750 SQUARE FEET ON LOTS 20,000 SQUARE FEET TO 60,000 UAR z EXISTING SQUARE FOOTAGE: 672 SOFT PROPOSED ADDITION: 78 SQFT ui TOTAL PROPOSED & EXISTING SQUARE FOOTAGE: 75 SOFT n P F I RST FLOOR PLAN P FOU N D A T I ON PLAN —1 14 = 1 -0 3 SCALE: 1 4 = 1 -0 SCALE. T/ " ' " " ' "/ O O ui 00 w 14'-10" 11'-O" 8'-6" Co LINE OF ROOF OVERHANG BELOW PROPOSED EXISTING ROOF TO REMAIN ROOF TO F - - - - - - - - - - - - - - 0 — � � — � � � MATCH LINE OF ROOF OVERHANG BELOW , n I PROPOSED WALLS BELOW EXISTING WALLS BELOW U J 3 3 2"X10 m p00 XISTN WALLBEL(W Ed I I N m EXISTING WINDOWS 3 Fq J J O O = I I w < ( EXISTING (2) 2"X10" HEADER I ¢ I riles m EXS ING WI DOWS m MkF I 3Ln 10 z I REMOVE -I I z I I Q EXIS nNG ( ) 2"X1 HE DER a iV a EXISTINGN I iV Lf) C7 C7 w EXISTING �T w z z 3'-0" KNEE WALL o STORAGE S-0" KNEE WALL ( — — I x x O T&G PLYWOOD DECKING I 3' O Kr EE W L NISHED ( — — I 3-0" K EE W LL TO REMAIN UNFI INFILL FRAME STAIR W O OPEN FRAMING OPENNING. MATCH U I PLYWOOD DECKING OPEN RAIL on o f — x ® E ISTI G w LINE OF 7'-0" N L- LINE C 7-0 OPE RAIL m -CEIL7IVG HEfGfiT— O NEIL HEIGjHT= I m o 3 Z L T R GE z I z w LINE F 7'- " LINE JOF 7'-,0" w _ I r REMOVE EXISTING = �_ — — I _ m O CEJLWG HEI H m w w I I WINDOW AND WALL x I rug z X z 00 0> I ^ W EXISTING 2"X12" RIDGE BEAM — I zo 00 0 m CV z a wOPEN RAIL IIII ma ^q- RID p o o p o EXISTING WINDOW ( o I Q IIII I p 0 OPEN RAIL o fel w _ LIN= OF 7'-O" 4 0 z I CEILING HEIGHT LINE (777- " I z W w CEILING HEIGHT o J LINE IF 7'- OPEN RAIL I I I z_ CEILIN HEIG T O LINE F 7'-0 z " I j� CEILI G HEI HT J OPE RAIL NCharles M . Thomas I I I I 8-6" 10'-4 8'-6" I 3'-0" KNEE WALL 3'-0" KNEE WALL I a r C h i ` e C ` o o I EE WILL I 3'-0 KNEE WALL PO BOX 877 JAMESPORT, NY 11947 (631) 727-7993 J w P71d• I I T N OJ J N I 3 1 EXISTING (2) 2"X10" HEADER I I a m m PROJECT p EXISTING WINDOWS I 3 EXIS ING{ ) 2"X1 HE DER 3 z 00 I ~ w — w z _-- EX5 ING W DOWS z w � EXISTING WALLS BELOW L — — — — — — — — — — — — — — — — — — — — — — — — — I m J X X _ W w LINE OF ROOF OVERHANG BELOW XISTNC WALLS BEL :w :l 6'-4" 28'-0" LINE OF ROOF OVERHANG BELOW ADDITION EXISTING ROOF FRONT TO BACK 34'-4" 10.5: 12 EXISTING ROOF PITCH PROPOSED FLOOR 10'-0" PL HT FRONT AND LEGEND 10'-0" PL HT BACK K - EXISTING ———_ - TO BE REMOVED DATE: 10/20/20 PROJECT No. P PROPOSED FRAME WALL DRAWING BY. MC SECO N D FLOOR PLAN P A M I N L A N 2 SCALE: 1/4" = 1'-0" 4 SCALE: 1/4" = 1'-0" EXISTING WINDOWS TO BE CHKBY. DWG No. EXISTING DOOR TO BE REMOVEDa- 002_ (�0 2OF 7 THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IN WHOLE OR IN PART, IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. TOP PLATE FRAMING TO ACCOMADATETABLE R 301.7 ALLOWABLE DEFLECTION OF STRUCRURAL MEMBERS , ' CORNER AND PARTITION POSTS PIPING — R602.7. 2 STUCTURAL MEMBER ALLOWABLE DEFLECTION RAFTERS AND CEILING Q JOISTS OR APPROVED TOP PLATES RAFTERS W/ GREATER L/1 80 , ROOF TRUSSSLOPES THAN > WNO/ TOP PLATES S FINISHED CEILING �\ SECOND STORY TOP PLATE— TABLE TABLE 3.1 ATTACHED TO RAFTERS 16d NAIL AT 24" O.C. TOP PLATE SEE DRILLING AND GYPSM BOARD INSTALLt� IN STUD INTERIOR WALLS AND H/180 ° „ ACCORDANCE WITH NOTCHING PROVISIONS PARTITIONS FLOORS AND PLASTERED L JOIST IS PERMITTED TO / 360 D BE CUT OR NOTCHED BORED HOLE MAX CEILINGS FLOOR JOIST— BETWEEN THESE LIMITS WALL STUD— DIAMETER 60% ALL OTHER STRUCTURAL L/240 BORED HOLE MAX z SEE DRILLING AND SEE DRILLING AND OF STUD DEPTH MEMEBERS DIAMETER 40% o BOTTOM PLATE NOTCHING PROVISIONS NOTCHING PROVISIONS EXT. WALLS W/ PLASTER OR H/360 OF STUD DEPTH _ WFCM SECTION 3.3.1.1.1 1/3 SPAN 1/3 SPA WFCM SECTION 3.4.1.1.1 WOOD STRUCTURAL PANEL » STUCCO FINISHE „ NSTALLED IN ACCORDANCE 5/8 MIN. TO EDGE 5/8 MIN. TO EDGE 1 � „ EXT. WALLS-WIND LOADS L/240 T d NAIL AT 6 O.C. WITH WFCM TABLE 3.1 WITH BRITTLE(b) FINISHES o T ALL PANEL EDGES) H8d NAIL AT 12" O.C. ON ALL EXT. WALLS-WIND LOADS L/240 5/8" MIN. TO EDGE JOIST ENDS TO BE FRAMING MEMBERS NOT AT NOTCH MUST NOT EXCEED WITH FLEXIBLE(o) FINISHES NOTCH MUST NOT EXCEED NOTES: L= SPAN LENGTH, H = SPAN HEIGHT 25% OF STUD DEPTH —/ Cn FOR BLOCKING BLOCKED AGAINST q CORNER DETAIL PANEL EDGES 40% OF STUD DEPTH �, BAND JOIST AND BRIDGING ROTATION IN ACCORDANCE ( ) a. The wind load shall be permitted to be taken as 0.7 times the TOP PLATE OR BLOCKING SEE WFCM SECTION 3.3 WITH WFCM 3.3.1.3—END RESTRAINT GYPSM BOARD INSTALLED IN component and cladding loads for hte purpose of the determining BORED HOLES SHALL NOT / w AND 3.3.1.4 BRIDGING d NAIL AT 6" O.C. ACCORDANCE WITH WFCM TABLE 3.1 BORED HOLES SHALL NDT deflection limits herein. BE LOCATED IN THE SAME IF HOLE IS BETWEEN 40% AND 60% o ALL PANEL EDGES b. For cantilever memebers, L shall be taken as twice the lenght CROSS SECTION OF CUT OR OF STUD DEPTH, THEN STUD MUST BE BEARING ) BE LOCATED IN THE SAME of the cantilever. WALL CROSS SECTION OF CUT OR 5/ MIN. TO EDGE c. For aluminum structural members or poneles used in roofs or DS�CCESSIVEDSNUDSOARETDOUBLED 1 IN.x4 IN. RIBBON walls of sunroom additions or patio covers, not supporting edge of AND SO BORED cn CUT INTO STUD — glass or sandwich panels, the total load deflection shall not z LAP JOIST 3 IN. MIN. exceed L/60. For sandwich panels used in roofs or walls of 0 r` BAND JOIST BOTTOM PLATE FOR FIRE BLOCKING WOOD STRUCTURAL PANEL WFCM 2015 SBC HIGH WIND EDITION sunroom additions or patio covers, the total load deflection shall WFCM 2015 SBC HIGH WIND EDITION � N OR BLOCKING INSTALLED IN ACCORDANCE not exceed L/120 16d NAIL AT 24" O.C. WITH WFCM TABLE 3.1 w TABLE R 301.2.2.2.1 SILL PLATE JOIST o SECTION 3.4.3,1 .1 FIGURE 3.313 WALL BRACING ADJUSTMENT FACTORS BY ROOF SECTION 3.4.2.1 .1 FIGURE 3.3 A ° 8d NAIL AT 6" O.C. ON ALL COVERING DEAD LOAD CRAWL SPACESUBFLOOR FRAMING MEMB,�RS AT PANEL NOTCHING AND BORED HOLE LIMITATIONS ROOF/CEILING ROOF/CEILING NOTCHING AND BORED HOLE LIMITATIONS OR BASEMENT EDGES AND 12 O.C. ON ALL FOUNDATION MONOLITHIC FRAMING MEMBERS NOT ATDEAD LOAD DEAD LOAD FOR EXTERIOR WALLS AND BEARING WALLS SLAB—ON—GRADE E CORNER DETAIL PANEL EDGES FOR INTERIOR NONBEARING WALLS FOUNDATION (b) INSIDE WALL SUPPORTING 15 psf or less 25 psf PLATFORM FRAMING INTERMEDIATE BALLOON FRAMING ER FRAMING NOTCHING AND BORED HOLE LIMITATIONS ROOF ONLY 1.0 1.2 0 EXTERIOR CORN FOR EXTERIOR BEARING AND INTERIOR ROOF PLUS ONE STORY 2x4 CONTINUOUS N BEARING WALL LATERAL BRACE AT 6 O.C. LU NON— BEARING WALLS: R602.6 (1 )) 8c (2) FOR SI: 1 POUND PER SQUARE FOOT = 0.49 kN/M(2) TYPICAL WALL FLOOR & ROOF FRAMING JOISTS a. LINEAR INTERPOLATION SHALL BE PERMITTED 0 (� WIND—BORNE DEBRIS PROTECTION FASTENING SCHEDULE 2-10d NAILS FOR WOOD STRUCTURAL PANELS ROOF FRAMING DOUBLE TOP PLATE (a TRUSS OR CEILING JOIST 11 W FASTENER SPACING (inches) >< SEE STUD TO RAFTER Z SECTION A—A C PPLE TUD OR STUD TO STUD DETAIL i GABLE END TRUSS 3: 0 FASTENER SPAN 4 FEET 6 FEET BLOCKING E" T PINEC 0 < 4 FEET < PANEL SPAN < PANEL SPAN ENDWALL ROQUIREDORS W 0 U TYPE - < 6 FEET < 8 FEET ALL SPACING A A — — ALLOWS E CH SIDE NAILHOLDDOWN S � NO. 8 WOOD SCREW 16" 10" 8" INSTALLATION ANCHOR WITH 2" EMBEDMENT HEADER STUDS FULL LENGTH 5d COOLER NAILS AT 10" O.C. Q LENGHT DOUBLE q q WA STUDS _ (( �1) ° ° CONNECTED TO BLOCKING NOTE: 2"x4" BLOCK NAILED TO EACHI— AT,HARDWARE° CORNER STUD UPLIFT CONNECTION IS REQUIRED BRACE WITH 4-10d NAILS NO. 10 WOOD SCREW 16" 12" 9" HOLDDOWN ° o TRANSFER SHEAR TYPIC L AT EACH END OF HEADER AND Z ANCHOR WITH 2 EMBEDMENT (HDU) CONN CTO S AT BOTTOM OF HEADER STUDS IN GYPSUM BOARD ° ° ° NOTE: SIMILAR REQUITED CO NEC R ADDITION TO CONNECTORS AT 5d COOLER NAILS AT 7" O.C. W LENGHT ° ° CONNECTION AT EA H SIDE R UIR WALL STUDS AND AT TOP AND Z Q ° FOUNDATION. BOTTOM OF CRIPPLES 20 GAUGE STRAP w _ 2-16d COMMON ° ° NAILS AT6' O.C. FLOOR BRACING AT END BAYS 10-8d NAILS o LLJ (� 1/4" LAG SCREW BASED ANCHOR 16" 16" END WALL 16" SIDE WALL Q TYPICAL FRAMING AND UPLIFT WITH 2 EMBEDMENT I - Q LENGHT (WFCM FI GU RL— 3. 6 ) CONNECTIONS FOR OPENINGS „ v fy SUBFLOOR 8d NAIL AT 4 O.C. ENDWALL STUDS a. THIS TABLE BASED ON 180 MPH WIND SPEEDS AND A 33 FOOT MEAN ROOF HEIGHT. I ; � FACE OF FOOTING CEILING BRACING GABLE ENDWALL b. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. 12" MAX. WFCM FIGURE 11 FASTENERS SHALL BE LOCATED NOT LESS THAN 1" FROM EDGE OF PANEL. BAND JOIST ::D 0 ( ) ON c. ANCHORS SHALL PENETRATE THROUGH THE EXTERIOR WALL COVERING WITH AN CD U_ NAILS BASED EMBEDMENT LENGHT OF NOT LESS THAN 2" INTO THE BUILDING FRAME. o o FASTENERS SHA9 L 7777"77 SHEAR WALL REQUIREMENTS BE LOCATED NOT LESS THAN 2 1/2 FROM THE EDGE OF CONCRETE BLOCK OR MASONRY. �,�,, w s: r TOP PLATE UQ WoJ d. PANELS ATTACHED TO MASONRY OR MASONRY/STUCCO SHALL BE ATTACHED USING T ° PROVIDE RAFTER TO RIDGE TENSION STRAP VIBRATION—RESISTANT ANCHORS HAVING AN ULTIMATE WITHDRAWAL CAPACITY OF NO ,� � H NO CEILING CENTER 2x BLOCKING RIDGE HANGERS IF o H/2 BUT NEED OT � ,� DIAPHRAGM USE 8-8d COMMON NAILS ° �y THBUTNEED NOT REQUIRED ON SHEATHING JOINT RAFTER TAILS ARE NOT EACH END OF 1 -1 4 0 LESS THAN 1,500 POUNDS. ° ° EXC ED 15 FT. AX. D 40 FT. MA . STRAPPED TO TOP / N WOOD STRUCTURAL PANELS SHALL HAVE A MINIMUM THICKNESS OF 7/16 INCH (11.1 m) o ° 15/32 WOOD STRUCTURAL PANELS 20 GAUGE STRAP HOLDDOWN ° CORNER STUD , 0 GABLE FACE AND ON WALL BELOW PLATE OF WALL BELOW z (HDU) ° ° ° CONNECTED To BASED ON SHEARWALL REQUIREMENTS o U —ROOF RAFTER p o o TRANSFER SHEAR FOUNDATION CLEARANCE FROM SLOPES GABLE ENDWALL, BALLOON FRAMING o ° DOUBLE PREFERRED METHOD 2 0 G A. STRAP— STUD M .) 1 1" WIDE MIN. AT HA DINWARE o RAFTER 4 HOLD DOWN ALLNAFRAMING IL AT 'MEMBERS W/(8) 8d NAILS EACH SIDE BRACKETS AT SHEAR WALL CORNERS, NOT AT PANEL EDGES WINDOW AND DOOR OPENINGS: G'Y'PSUM BOARD Z W (FLOOR TO FLOOR & FLOOR TO FOUNDATION; WFCM 16d NAIL AT RIDGE BEAM M FLOOR TO FLOORPHD5 24 O.C. RIDGE TENSION STRAP DETAIL- Cz TABLE 8301 . 5 NOTESN U CONNECTION � FOR SI: 1 POUND PER SF= 0.0479 kN/M(2), 1 POUND = 4.45N. SIDE WALL a. ELEVATED GARAGE FLOORS SHALL BE CAPABLE OF SUPPORTING �- 8d NAIL AT 6" A 2,00 POUND LOAD APPLIED OVER A 20 SQUARE INCH AREA. ^, EXTERIOR WALL STRAPPING SCHEDULE O.C. (ALL PANEL b. APPPLIED TO ATTIC SPACES MEETING THE REQUIREMENTS IN T A B L E R301 . 5 VJ AREA HOLDDOWN USED / LENGTH NUMBER OF CAPACITY OF HOLDDO NS NOTES EDGES) SECITRON R802.4.1 FOR CONVENTIONAL CEILING JOISTS AND NAILS SECTION R802.10.7 FOR TRUSSES. ATTICS WITHOUT STORAGE ARE WOOD STRUCTURAL PANEL THOSE WHERE THE MAXIMUM CLEAR HEIGHT BETWEEN JOINST AND RIDGE SIMPSON CS-20-40 INCHES MIN. 6-8d PER RAFTER 602 LB RAFTER TO RAFTER INSTALLED IN ACCORDANCE WITH RAFTER IS LESS THAN 42 INCHES, OR WHERE THERE ARE NOT TWO Simpson Strong — Tie RAFTER TO STUD SIMPSON H-7 ANCHOR 4-8d TO RAFTER 985 LB PER EVERY RAFTER NAILING SCHEDULE (TABLE 3.1, OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION MINIMUM UNIFORMLY DISTRIBUTED LOADS ( PSI ) T 8-8d TO STUD CONNECTION CAPABLE OF CONTAINING A RECTANGLE 42 INCHES HIGH BY 2 >- 2-8d TO PLATES WCFM HIGH WIND EDITION) FEET WIDE, OR GREATERE, LOCATED WITHIN THE PLANE OF THE ■� z A35— Chimney Framing , FLOOR TO FLOOR SIMPSON CS-20-40 INCHES MIN. 40-8d 1005 LB PER EVERY STUD (A) OUTSIDE CORNER DETAIL TRUSS. FOR ATTICS WITHOUT STORAGE, THIS LIVE LOAD NEED NOT E CONNECTION BE ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE LOAD LIVE LOAD 3 RAFTER RIDGE DETAIL— STUD TO SILL PLATE SIMPSON H-8 5-8d TO STUD 745 LB EVERY STUD REQUIREMENTS.R00F4-8d TO PLATE GYPSUM BOARD c. INDIVIDUAL STAIR TREADS SHALL BE DESIGNED FOR THE C � 8d NAIL AT UNIFROMLY DISTRIBUTED LIVE LOAD OR A 300 POUND Cn SIMPSON STRONG TIE HDU 6" O.C. (ALL CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE EXTERIOR BALCONIES 40 CI) w * NOTES: SIZE PER MOST RECENT ATALOG INCHES, WHICHEVER PRODUCES THE GREATER STRESSES. 3 SCALE: N.T.S. ALL STRAPPING INDICATED MEETS OR EXCEEDS THE REQUIREMENTS IN THE SBCCI (STANDARD FOR HURRICANE RESISTANT RESIDENTIAL IDE WA PANEL d. A SINGLE CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT CONSTRUCTION, SSTD 10-99) TABLE 305 F1 FOR EAVE CONNECTIONS, TABLE 305 F2 FOR UPLIFT LOADS AT GABLE END WALLS AND ° EDGES) ANY POINT ALONG THE TOP DECKS 40 (� TABLE 3.2 FOR FOUNDATION CONNECTIONS. NAILING OVER STRUCTURAL WOOD PANEL SHEATHING IS ACCEPTABLE AS LONG AS MIN. e. SEE SECTION R502.2. FOR DECKS ATTACHED TO EXTERIOR NAIL PENETRATION INTO FRAMING IS ACHIEVED. WALLS. WOOD STRUCTURAL f. GUARD IN - FILL COMPONENTS (ALL THOSE EXCEPT THE PASSENGER VEHICLE GARAGES 50 n-� co SII * INSTALL THROUGH FIRST FLOOR SHOE. PANEL INSTALLED IN HANDRAIL) , BALUSTERS AND PANEL FILLER SHALL BE DESIGNED �J L x �I ACCORDANCE WITH TO WITHSTAND A HORIZONTALLY APPLIED NORMAL LOAD OF 50 ATTIC WITHOUT STORAGE 10 0 NAILING SCHEDULE \_16d NAIL AT POUND ON AN AREA EQUAL TO 1 SQUARE FOOT. THIS LOAD NEED m ®) (TABLE 3.1, WCFM 2015 J 24" O.C. NOT BE ASSUMED TO ACT CONCURRENTLY WITH ANY OTHER LIVE ATTICS WITH STORAGE 20 HIGH WIND EDITION) ®I a LOAD REQUIREMENT. a g. APPLIES TO ATTICE SPACES NOT MEETING THE REQUIREMENTS ROOMS OTHER THAN SLEEPING ROOMS 40 ® z FOR STORAGE PER FOOTNOTE b. SEE SECTION R802.4.2 FOR 8d NAIL AT 6" O.C. ON CONVENTIONAL CEILING JOISTS AND SECTION R802.10.6 FOR ®� ALL FRAMING MEM3ERS TRUSSES. FOR ATTICS WITH LIMITED STORAGE AND CONSTRUCTED SLEEPING ROOMS 30 AT PANEL EDGES AND g) INSIDE CORNER DETAIL WITH TRUSSES, THIS LIVE LOAD NEED ONLY BE APPLIED TO THOSE ( PORTIONS OF THE BOTTOM CHORD OF NOT LESS TAHN TWO 12" O.C. ON ALL ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION STAIRS 40 FRAMING MEMBERS NOT CONTAINING A RECTANGLE 42 INCHES (1067mm) HIGH OR GREATER SHEET NO. AT PANEL E)GES BY 2 FEET (610 mm) WIDE OR GREATER, LOCATED WITHIN THE GUARDRAILS AND HANDRAILS 200 PLANE OF THE TRUSS. THE RECTANGLE SHALL FIT BETWEEN THE ' BRACING DETAIL TOP THE BOTTOM CHORD AND BOTTOM ANY OTHER TRUSS MEMBER, PROVIDED THAT EACH OF THE FOLLOWING CRITERIA IS ( 2 '� CORNER MET: P' EXTERIOR C 0 R N E R FRAMING 1. THE ATTIC AREA IS ACCESSIBLE BY A PULL - DOWN STAIRWAY OR FRAMED OPENING IN ACCORDANCE WITH sECTION 807.1:AND 3 SCALE: N. T.S. 2. THE TRUSS SHALL HAVE A BOTTOM CHORD PITCH LESS THAN Simpson Strong — Tie 2:12. h ATTIC SPACES SERVED BY A FIXED STAIR SHALL BE DESIGNED HDU TO SUPPORT THE MINIMUM LIVE LOAD SPECIFIED FOR SLEEPING ROOMS. (TABLE 4 WFCM 2015 HIGH WIND EDITION) The design of this structure is based upon prescriptive approach using the ( TABLE 2 WFCM 2015 HIGH WIND EDITION ) SILL OR BOTTOM PLATE TO FOUNDATION ANCHOR BOLT Wood Frame Construction Manual (WFCM) 2015 130 MPH COPYRIGHT 2015 SBC published by The American Forest and Paper Association. Non- Structural lements NAILING SCHEDULE CONNECTIONS RESISTING UPLIFT are based upon the 2020 NEW YORK STATE RESIDENTIAL CODE. LATERAL & SHEAR LOADS GENER AL NOTES: MAX. ANCHOR BOLT SPACING (INCHES) ANCHOR BOLT CONNECTION FOUNDATION NOTES 1,2,3,4 � For the Climatic and Geographical Desi n Criteria, see Table R301.2 1 On 1• All works shall be performed in accordance with all State, �' :• .'.--t�^,� ���% !► - '� e RESISTING SUPPORTINGmunici al local zoningand buildingcodes and ordinances NUMBER OF NAILS NAIL SPACING g havingP jurisdiction anbest standrds of construction t JOINT DESCRIPTION 5/e" ANCHOR BOLTS 39 sheet no. 1 COMMON NAILS 1 - FLOOR All non engineered lumber to be Douglas Fir#2 or better LATERAL AND SHEAR LOADS 2 - FLOORS 5/8" ANCHOR BOLTS 26 practice. 4-8d PER RAFTER Wind Limitations-Section R301.2.1 The American Institute of Architects Conditions shall apply x 1. PRESCRIPTIVE LIMITS ARE BASED ON A SUMPTIONS IN TABLE 3. g { { ) t0 all work performed On this RAFTER TO TOP PLATE TOE-NAILED Design R301.2.1.1. See Table R301.2. 4 A for Wind-Born Debris p project. f^� 2. WHEN ANCHOR BOLTS ARE USED TO RESIST UPLIFT, LATERAL, AND SHEAR LOADS, THE MAXIMUM ANDCHOR BOLT SPACING SHALL NOT EXCEED THE Protection Fastening Schedule For Wood Structural Panels 2. The Contractor shall verifyall conditions at the site. An ��''• �., � ' • Y 4-Sd PER JOIST LESSER OF THE TABULATED. g ) discrepancies must be brought to the attention of the Architect CEILING JOIST TO TOP PLATE TOE-NAILED 3. FOR THREE SECOND GUST WIND SPEEDS GREATER THAN 130 MPH, CEILING JOIST TO PARALLEL RAFTER FACE-NAILED 9-16d EACH LAP Live Load-Section R301.5 prior to commencement of construction. The Contractor shall be Light and Ventilation-Section R303 responsible for corrections not reported once he has started work CEILING JOIST OVER PARTITIONS FACE-NAILED 9-16d EACH LAP Minimum Room Area-Section R304 except for hidden job conditions. z Ceiling Height-Section R305 3. Contractor shall guarantee to the Owner that all materials and O COLLAR TIE TO RAFTER FACE-NAILED 6-8d PER TIE Sanitation-Section R306 equipment incorporated in the work will be new, and that all work _ 2-8d EACH END Toilet Bath and Shower Space-Section R307 will be of good quality, free from faults and defects for a period BLOCKING TO RAFTER TOE-NAILED Glazing-Section R308 of one year form the date of the final Certificate of Occupancy. i TRIM BOARD TO RAFTER END-NAILED 2-16d EACH END Garages and Coarports-Section R309 4. The Architect shall not be responsible for the construction means, Emergency Escape and Rescue Opening-Section R310 method, techniques, sequences or procedures, or for the safety WALL FRAMING Means of egress-Section R311 precautions and programs in connection with the work, and he 2 Landing-Section R311.3 shall not be responsible for the contractors failure to carry out TOP PLATE TO TOP PLATE FACE-NAILED -16d (SEE NOTE 1) PER FOOT Ramps-Section R311.6 the work in accordance with the construction documents. The Stairway-Section R311.7 Architect shall not be responsible for the acts or omission by TOP PLATE AT INTERSECTION FACE-NAILED 4-16d JOINTS - EACH SIDE V)Handrail-Section R311.7.8 the contractor No changes shall be made in the documents w 2-16d 24' O.C. Guards-Section R312 and/or the building as designed without the expressed written o / 9 9 P STUD TO STUD FACE-NAILED Smoke Alarms-Section R314 consent of the Architect. HEADER TO HEADER FACE-NAILED 16d 16" O.C. ALONG EDGES Carbon Monoxide Alarms - R315 5. The contractor and all subcontractors shall maintain continuous Foam plastic-Section R316 2-16d PER 2X4 STUD insurance coverage statutory policies (Worker TOP OR BOTTOM PLATE TO STUD (END-NAILED) Flame Spread and Smoke-Section R315 Compensation, etc.) and general liability in an mount not cn 3-16d PER 2X6 STUD Insulation-Section R316 z (o 4-16d PER 2X8 STUD Dwelling Unit Separation-Section R317 less than $ 5 million and automobile liability and damage O Moisture Vapor Retarders-Section R318 coverage not less than $ 2 million. The Architect shall be in N FACE-NAILED 2-16d (SEE NOTE 1,2) PER FOOT Protection Against Decay-Section R317 named insured on any and all policies. > FLOOR FRAMING Protection Against Termites-Section R318 6. Provide 0.025" of a meatal shield, other than aluminium, over fibrous of Site Address-Section R319 insulation at all perimeter sills. 4-8d PER JOIST Accessibility-Section R320 7. All wood in contact with concrete or masonry to be Wolmanized JOIST TO SILL TOP PLATE TO GIRDER TOE-NAILED Elevators and Platform lifts -Section R323 or pressure creosoted. Flood Resistant Construction-Section R324 8. A single station smoke detector alarm device shall be installed BRIDGING TO JOIST TOE-NAILED 2-8d EACH END in each bedroom, on all floors and shall be all interconnected per code. 3-16d Foundation-Chapter 4 9. All bathroom without operable windows to be mechanically ventilated BLOCKING TO SILL OR TOP PLATE (TOE-NAILED EACH BLOCK per New York State Code. Design based upon presumptive load bearing values of sandy gravel and or gravel as P LEDGER STRIP TO BEAM FACE-NAILED 3-16d EACH JOIST at 3000 pounds 10. Heating to be designed to provide 70 degrees F. with outdoor c 3-8d PER JOIST per square foot. Contractor to consult Arcitect if different soil materials are designed air-temperature of 0 degrees F. and 15 MPH wind. JOIST ON LEDGER TO BEAM TOE-NAILED found upon excavation, 11. All electrical work to be in accordance to the rules and 0 BAND JOIST TOJOIST END-NAILED 3-16d PER JOIST or test hole, for alternative footing and foundation wall design. regulation of N.Y.B.F.U. and a N.Y.B.F.U. certificate is to be presented to the Owner at the completion of the job. �� N BAND JOIST TO SILL OR TOP PLATE TOE-NAILED 3-16d PER JOIST Foundation Notes: 12. Plumbing Installation to comply with State and Local codes ROOF SHEATHING 5/8" Ancor Bolts (SSTB-28) See chart on this sheet for spacing and the sewage disposal system to meet Health Department standards. L i 0 8" poured concrete foundation wall, 8'-0" high, 3000 # test 13. Do not scale drawings. Use figure dimensions only. ^ f STRUCTURAL PANELS RAFTERS OR TRUSSES SPACED UP TO 16" OC 8d 6" EDGE / 6" FIELD Minimum depth-Section 403.1.4, 48' minimum coverage to top of footing 14. All work to conform to the rules and regulations of the New York l v Energy Conversation Construction Code. All glazed area to be double 16"x8" poured concrete wall footings, 3000# test glazed and all exterior door to have insulated cores. 0 GABLE ENDWALL RAKE OR RAKE TRUSS W 0 GABLE OVERHANG 8d 6" EDGE 6" FIELD 2-1 3/4"x11 7/8" Microlom Girder (or 3 1/2"x11 7/8" Power Beam) 15. The insulation protection as indicated on these plans exceeds 7- Damp W 4" poured concrete floor slab with 6x6x 10 mesh and vapor barriers. Q GABLE ENDWALL RAKE OR RAKE TRUSS W STRUCTURAL OUTLOOKERS 8d 6" EDGE / 6" FIELD Dap proofing at exterior foundation below grade-Section R406 16. These ndrawings andaspecf cation are instruments of service and >-> GABLE ENDWALL RAKE OR RAKE TRUSS W1 LOOKOUT BLOCKS 8d 4" EDGE 4" FIELD 30"x30"x12" deep poured concrete column footings, 3000# test shall remain the property of the Architect whether the project for > 0 / CONCRETE TO HAVE 5 TO 7% AIR-ENTRAINMENT which they made is executed or not. They may not be used CEILING SHEATING Deck and porch flootings as noted, 3000# test, 48" minimum buried depth on any other project except by written authorization of the Architect." EDGE 10" FIELD 17. Architect has not been retained for site supervision, on-site 0 0 GYPSUM WALLBOARD 5d COOLERS 7 / Foundation wall to extend a minimum 8" above finished grade inspection and certifications as required or requested by the Owner, Q WALL SHEATHING All footing to be carried down to undisturbed soil contractor or local building department. No footing shall be set higher than a 30 degree angle from any other footing I STRUCTURAL PANELS STUDS SPACED UP TO 16" OC 8d 6" EDGE / 12 FIELD Pour no concrete on frozen ground or in freezing water. O Provide 3 1/2' steel lally columns. L.- Q Backfill shall not be placed against the wall until the wall has sufficient UPLIFT - CONTINUOUS PATH CONNECTORS strength and has been anchored to the floor above, or has been sufficiently CC L.- braced to prevent damage by the backfill (Section R404.1.7.) USE SIMPSON STRONG-TIE CONNECTORS G Floors - WFCM Prescriptive Method. FOLLOW PRODUCT SELECTION GUIDE AND GYPSUM WALLBOARD 5d COOLERS 7" EDGE z Floor framing shall be nailed in accordance with Table 2 WFCM HIGH WIND EDITION. INSTALLATION MANUAL FOR HIGH WIND RESISTANT / 10" FIELD Draftsto pp'rn g - Section R502.12 CONSTRUCTION CATALOG C-HW02 Q W Fireblocking - Section R502.13. z Q ANCHOR BOLTS IN FOUNDATION USE: W Floor Construction: SST828 WITH BEARING PLATE, SEE FOUNDATION Simpson Strong-Tie r- 3/4" plywood subfloor, fasten per Table 3.1 WFCM. NOTES FOR SPACING 0210 2X6 Q V 1 Floor joists: see Foundation and Floor Plans, spacing as noted. Q Fasten per Table 3.1 WFCM. SILL PLATE TO RIM JOIST USE: Uff] AT EACH RAFTER 2-2x6 ACQ sill with termite shield and sill seal. LTP4 16" O.C. AT EXTERIOR PERIMETER Q Finish floors per agreement. AND GARAGE/HOUSE COMMON WALL 4-10d X 1 1/2" L] FLOOR SHEATHING Wall construction - WFCM Prescriptive Method. USE: (4)-8d NAILS AT EACH END Wallfroming and finishing shall be nailed and or screwed in accordance with GARAGE STUD GARAGE SILL PLATE USE: STRUCTURAL PANELS WFCM, Table 2 and Section 4 NOTE: 1x6 fascia, wrap SSP CONNECTOR AT 16 O.C. 1' OR LESS 8d 6" EDGE / 12" FIELD Overhangs as noted. USE (4)-8d NAILS AT EACH END ATTACH LEDGER TO FRAMING GREATER THAN 1" lOd 6" EDGE / 6" FIELD Vinyl Allum numegutterstand leaders. Siding: see Elevations. RIM JOIST TO STUD CONNECTION USE: MEMBER WITH 2-1/2" X 5" LAG Tyvek housewrap. MTS 36, 16" O.C. BOLTS AT 16" ON CENTER 1/2" plywood sheating, see fastening schedule, Table 3.1, 3.9 WFCM. USE (4)-8d NAILS AT EACH END 2x4x Studs ® 16' o.c. with 2x4 shoe and double 2x4 plate FLOOR TO FLOOR CONNECTION USE: 1/2" Gypsum wall board MSTA 36, 16" O.C. 5/8••Type X GWB in garage. (2) layers J' GWB at fire partition Simpson Strong-Tie USE (4)-8d NAILS AT EACH END O 1/2" MR GWB in wet areas RAFTER TO STUD CONNECTION USE: p gTle Ir- At least one window in each sleeping room shall comply with the exit regirements MTS 36, EACH ROOF RAFTER U210 2X6 N of section R310. USE 8 16d NAILS AT EACH END Note drilling and notching limitations in figure R602.6(1) for bearing walls and RAFTER TO RIDGE TO RAFTER CONNECTION USE: AT EACH CEILING JOIST Z figure R 602.6(2) for non - bearing walls. H7 EACH ROOF RAFTER SIMPSON STRONG - TIE Follow exterior corner framing detail figure R602.10.5 4-10d x 1 1/2" 0 1 1 /4" COIL STRAP - DECK POST TO CONCRETE CONNECTION USE: ,t Roof assemblies - WFCM Prescriptive Method (WFCM table 2) Asphalt strip shingles PBS44A FOR EACH POST shall have minimum of six 6 fasteners 16 O.C. USE - ( ) per shingle (section R905.2.5) DECK POST TO GIRDER CONNECTION USE: � NAILS AT EACH STUD Underloyment application (Section R905.2.7.)nailing see table 3.8 Q w SIMPSON For roof slopes of two (2) units vertical in twelve (12) units horizontal (17- PC44 FOR EACH POST � J �► SIMPSON H-8 USE W/ONLY s �� >� MIN OVERLAP IS 12 5- 8D TO STUD ONE SILL � ANCHOR BOLT (14 ) percent slope), o � BP-3 PLATE GIRDER TO DECK JOIST CONNECTION USE: Sim son Stron -Tie up to four (4) units vertical twelve (12) units horizontal {33 -percent slope ) p g 4- 8D TO PLATE PLATE O 7" MINIMUM EMBEDMENT underlayment MTS12 ® EACH JOIST e 0210 2X6 (EVERY STUD) STUD TO SI shall be two (2) lyers applied in the following manner. Apply A 19-inch (483)strip PORCH POST TO DECK USE: ,• ATTACH T (SEE ANCHOR SCHEDULE, of ON DWGS A-3.1 AND A-3.2) PS720 (ALIGN WITH JOIST BELOW) o.e AT EACH DECK/PORCH JOIST underlayment felt layers with and starting at the eaves , fastened sufficiently to •�, hold in place. r, Y8" HDSIMPSON Startingat the eave apply 36- inch wide 914 mm sheets of underlayment, PORCH POST TO GIRDER USE: R USE: '1 J %" HDU PP Y ( ( yment, PORCH ROOF RAFTER TO GIRDER USE: • overlapping H2.5A AT EACH ROOF RAFTER " ti (14) SDS Y" X 3" WOOD SCREWS o successive sheets 19 inches (483mm), and fstened sufficiently to hold in place. 4-1Od x 1 1/2 ' 7" MIN EMBEDMENT For roof slopes of four 4 units vertical in 12 units. N • °• (SEE FOUNDATION PLANS A-3.1 AND ° P ( ) ( ) TYPICAL PORCH / DECK LEDGER - A-3.2 Ice Protection (Section R905.1.2) A-3.2 FOR LOCATION) CONNECTIONS A ° ° °' '' (MINIMUM DOUBLE STUD) ° Underlayment in High wind (Section R905.1.1) A c•D, °° •'° •° •. SIMSON STRONG - TIE Flashing (Section R905.2.8) O » » Chimney and firespaces - Chapter 10 STU Y2 BEARING PLATE ° �'%- �° n ,c�.°a °D ' '� ° 1 1/4 COIL STRAP - 16 O.C. Energy Efficiency - Chapter 11, see attached report °a,-,1' °o,' o USE 4-8D NAILS ® EACH STUD, Mechanical - Chapter 12 DOUBLE 2X MIN. a General Mechanical System - Chapter 13 FOR HEADER OR . �.. o . D . o °D . °D . D �°d ��D ° ° Heaitng and cooling equipment - Chapter 14 BEAM ° a a °• al; a Exhaust Sustem - Chapter 15 > D' D .'�°�1' ;�, �•°• �1�e„ D' D Duct System - Chapter 16 .� z e N • °• " DOUBLE TOP PLATE MTS30 ROOF RAFTERS Combustion Air - Chapter 17 Simpson Strong-Tie �-/ Chimneys and Vents - Chapter 18 AC4 C 7N IN ° SSP Plumbing - Part VII AT EACH POST o SEE PLAN - 1 3/4" IMUM ,° °.°•e°'' 'n Flood Zone - 301.2.4 N EDGE DISTANCE �•, 9' D HEADER 'aa D °• ° LSTA21 Simpson Strong-Tie ( •` W FLOOR TO FLOOR KING STUDS CS20 1%" COILED Y2" THREADED ROD L CONNECTION STRAP. MIN 12" REQUIRED FOR STU 1/2---,, OVERLAP AT EACH JACK STUDS ' SIMPSON STRONG - TIE SIMPSON STRONG-TIE D x -� 1 1 /4" COIL STRAP - H2A 2"MINIMUM CNW NUT COUPLER o 16" O.C. USE 4-8D SIDECOVER (� AT EACH ROOF � . NAILS AT EACH STUD RAFTER USE 8-16D I MIN EDGE MIN OVERLAP IS 12 NAILS AT EACH END, JACK FID SILL ®® b DISTANCE* 12" MIN OVERLAP PER RT2.5 - - = . COMPONENT ;. STHD8 I.:ieu "`a `�� Cr"• -MIN EDGE SHEET STUD TO ROOF RAFTER N� :�:.. ��:P •.4:'' > CONNECTION FLOOR TO FLOOR Simpson Strong-Tie '• DISTANCE* WRAP UNDER SILL PLATE PING FORAB *NOTE: SEE MANUFACTURERS MIN. OVERLAP IS 12 ( FRAMED OPENING EXTERIOR WALL CONNECTIONS. AT EACH POST FOOTING MINIMUM DISTANCE CHART FOR SILL PLATE TO RIM JOIST AND CANTILEVER CONDITION INSTALLATION RIM JOIST TO STUD CONNECTION WALL TO FOUNDATION CONNECTION PORCH COLUMN CONNECTIONS