Loading...
HomeMy WebLinkAbout2021 3rd Qtr October 19, 2021 James Bunchuck Solid Waste Coordinator Town of Southold DSW 6155 Cox Lane P.O. Box 962 Cutchogue, NY 11935 Re:Town of Southold Landfill Landfill Gas Monitoring Program, Third Quarter 2021 D&B No. 5535 Dear Mr. Bunchuck: On September 24, 2021 D&B Engineers and Architects(D&B) completed the Third Quarter 2021 landfill gas monitoring event for the Town of Southold Landfill located on Cox Lane, off Middle Road (CR 48) in Cutchogue, New York. As partof this event, each of the existing fifteen (15) landfill gas monitoring wells (GMW-1 through 15) were screened utilizing a GEM 5000 Plus Landfill Gas Analyzer for the following parameters: temperature; oxygen levels; carbon monoxide levels; carbon dioxide levels; hydrogen sulfide levels; and lower explosive limit (LEL) for methane. Climatic conditions at the Town of Southold Landfill o on September 24, 2021 were approximately 65F with rain showers and wind speeds of approximately 10- 15 MPH. Enclosed with this letter is Figure 1, which shows the approximate locations of each existing landfill gas monitoring well. Also enclosed with this letter is Table 1, which lists all landfill gas monitoring wells and their corresponding measurements as measured during the September 24, 2021 monitoring event. As indicated in Table 1, methane, carbon monoxide, and hydrogen sulfide were not detected within any of the landfill gas monitoring wells. The next quarterly round of landfill gas monitoring is expected to be conducted during the Fourth Quarter of 2021. If you have any questions, please contact me at (516) 364-9890, Ext.3058. Very truly yours, Keith Robins, P.G. Associate KR/MFt/cf Enclosures Cc:F. DeVita (D&B) 5535\\KR101921JB_Ltr TABLE 1 TOWN OF SOUTHOLD LANDFILL LANDFILL GAS MONITORING PROGRAM THIRD QUARTER 2021 MONITORING EVENT Sampling Date: September 24, 2021 ParameterUnitGMW-1GMW-2GMW-3GMW-4GMW-5GMW-6RGMW-7GMW-8GMW-9GMW-10GMW-11GMW-12GMW-13GMW-14GMW-15 o TemperatureC18.118.618.118.218.118.218.118.118.118.118.119.918.418.118.3 Oxygen*%18.318.118.318.718.818.518.318.818.818.913.016.817.718.314.6 Carbon Dioxide%0.10.10.40.10.00.50.40.10.10.16.22.61.10.23.2 Carbon Monoxideppm000000000000000 Lower Explosive Limit - Methane%000000000000000 Hydrogen Sulfideppm000000000000000 NOTES: Typical atmospheric levels of oxygen range between 19.5% and 23.5% o C = Degrees Celsius % = Percent ppm = Parts Per Million *Atmospheric oxygen readings taken during the sampling event were between 18.4% and 18.8%, which is marginally lower than typical atmospheric levels. The oxygen readings within the monitoring wells are approximately 1-2% lower than expected. J:\\_HazWaste\\5535 (Southold GW and LFG Monitoring)\\Landfill Gas Monitoring\\2021 3Q\\Southold Landfill - Landfill gas monitoring 2021Q3Page 1 of 1 N W 9 } V h u —/ Y������ w. n,,..""' r ...��'"n, hvw m'`,,:, .. -, "„" ✓o ..^w„.^ n'u I'," ��' �.., "_ ^Y e"r, ��' r' r, i „I � u11 mm °^p I��n.,��, �' ,,mmw"'`"'�I�a IH4" � �, 4, �w' "' +'^�d��"w"*°�.. ,,.�"��m�,,'~'�Y„�mb�"^�..b ,.,,` ``^��""Xm",*�:`m�� ��' � ✓'so�l��u I R y ... 114 � I m. N b M 13 O 1 M W- N �p a Mn LEGEND 250 125 0 250 iiia GAS MONITORING WELLS SCALE IN FEET GMW-1 'NOTE:WELL SYMBOLS NOT TO SCALE �-� SOUTHOLD LANDFILL oJD�JD�� �+_� CUTCHOGUE, NEW YORK D&-B ENGINEERS AND ARCHITECTS LANDFILL GAS MONITORING �; WELL LOCATION MAP FIGURE No. 1