Loading...
HomeMy WebLinkAbout2021 1st Qtr March 12, 2021 James Bunchuck Solid Waste Coordinator Town of Southold DSW 6155 Cox Lane P.O. Box 962 Cutchogue, NY 11935 Re:Town of Southold Landfill Landfill Gas Monitoring Program, First Quarter 2021 D&B No. 5535 Dear Mr. Bunchuck: On March 4, 2021 D&B Engineers and Architects (D&B) completed the First Quarter 2021 landfill gas monitoring event for the Town of Southold Landfill located on Cox Lane, off Middle Road (CR 48) in Cutchogue, New York. As part of this event, eachof the existing fifteen (15) landfill gas monitoring wells (GMW-1 through 15) were screened utilizing a GEM 5000 Plus Landfill Gas Analyzer for the following parameters: temperature; oxygen levels; carbon monoxide levels; carbon dioxide levels; hydrogen sulfide levels; and lower explosive limit (LEL) for methane. Weather conditions on March 4, 2021 were observed to be overcast and approximately 32 degrees Fahrenheit. Enclosed with this letter is Figure 1, which shows the approximate locations of each existing landfill gas monitoring well. Also enclosed with this letter is Table 1, which lists all landfill gas monitoring wells and their corresponding measurements as observed during the March 4, 2021 monitoring event. As indicated in Table 1, methane, carbon monoxide, and hydrogen sulfide were not detected within any of the landfill gas monitoring wells. The next quarterly round of landfill gas monitoring is expected to be conducted during the Second Quarter of 2021 (May 2021). If you have any questions, please contact me at (516) 364-9890, Ext.3058. Very truly yours, Keith Robins, P.G. Associate KR/MFt/cf Enclosures Cc:F. DeVita (D&B) 5535\\KR030921JB_Ltr TABLE 1 TOWN OF SOUTHOLD LANDFILL LANDFILL GAS MONITORING PROGRAM FIRST QUARTER 2021 MONITORING EVENT Sampling Date: March 4, 2021 ParameterUnitGMW-1GMW-2GMW-3GMW-4GMW-5GMW-6RGMW-7GMW-8GMW-9GMW-10GMW-11GMW-12GMW-13GMW-14GMW-15 o TemperatureC3.62.82.12.07.36.24.78.25.47.68.86.26.16.15.3 Oxygen%21.021.021.420.313.018.420.216.318.721.320.914.720.921.513.6 Carbon Dioxide%0.20.40.10.17.83.41.14.42.70.10.96.50.60.26.2 Carbon Monoxideppm000000000000000 Lower Explosive Limit - Methane%000000000000000 Hydrogen Sulfideppm000000000000000 NOTES: Typical atmospheric levels of oxygen range between 19.5% and 23.5% o C = Degrees Celsius % = Percent ppm = Parts Per Million J:\\_HazWaste\\5535 (Southold GW and LFG Monitoring)\\Landfill Gas Monitoring\\2021 1Q\\Southold Landfill - Landfill gas monitoring 2021Q1Page 1 of 1 N W 9 } V h u —/ Y������ w. n,,..""' r ...��'"n, hvw m'`,,:, .. -, "„" ✓o ..^w„.^ n'u I'," ��' �.., "_ ^Y e"r, ��' r' r, i „I � u11 mm °^p I��n.,��, �' ,,mmw"'`"'�I�a IH4" � �, 4, �w' "' +'^�d��"w"*°�.. ,,.�"��m�,,'~'�Y„�mb�"^�..b ,.,,` ``^��""Xm",*�:`m�� ��' � ✓'so�l��u I R y ... 114 � I m. N b M 13 O 1 M W- N �p a Mn LEGEND 250 125 0 250 iiia GAS MONITORING WELLS SCALE IN FEET GMW-1 'NOTE:WELL SYMBOLS NOT TO SCALE �-� SOUTHOLD LANDFILL oJD�JD�� �+_� CUTCHOGUE, NEW YORK D&-B ENGINEERS AND ARCHITECTS LANDFILL GAS MONITORING �; WELL LOCATION MAP FIGURE No. 1