HomeMy WebLinkAbout48128-Z �o��SUFFOLk G� Town of Southold 12/29/2022 P.O.Box 1179 , 0 co z 53095 Main Rd od} Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43736 Date: 12/29/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2120 N Sea Dr., Southold SCTM#: 473889 Sec/Block/Lot: 54.-5-45.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/27/2022 pursuant to which Building Permit No. 48128 dated 7/28/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels as applied for. The certificate is issued to Burrascano Jr,Joseph&Dona of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48128 12/20/2022 PLUMBERS CERTIFICATION DATED Aut orize S' n ture oy�g�4FQ TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy • �g� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48128 Date: 7/28/2022 Permission is hereby granted to: Burrascano Jr, Joseph 2120 N Sea Dr Southold, NY 11971 To: Install roof mounted solar panels to an existing single family dwelling with flood permit as applied for. At premises located at: 2120 N Sea Dr., Southold SCTM #473889 Sec/Block/Lot# 54.-5-45.4 Pursuant to application dated 6/27/2022 and approved by the Building Inspector. To expire on 1/27/2024. Fees: SOLAR PANELS $50.00 CO-RESIDENTIAL $50.00 ELECTRIC $100.00 Flood Permit $100.00 Total: $300.00 Building Inspector o��OF SOUryo! � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlina-town.southold.ny.us Southold,NY 11971-0959 COM'ti,��` BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joseph Burrascano Jr Address: 2120 N Sea Dr city,Southold st: NY zip: 11971 Building Permit#: 48128 Section: 54 Block: 5 Lot: 45.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Long Island Power Solutions License No: 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Energy Storage X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 100A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 13.2kW Roof Mounted PV Solar Energy System w/ (33) 40OW Modules, 40A AC Disc 100A Essential Load Sub 24 Circuits / 19 Used, TRW Generac PowerCore, PWRcell 18 Notes: Solar & Energy Storage Inspector Signature: Date: December 20, 2022 S. Devlin-Cert Electrical Compliance Form SOF'So UTy 7,4 C/O r S'c a •12( - -- -- # * TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] 'FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: At,I (^S-41) ,a�hv& /karl vej Ar ,�,04. IL r %,,A doo, A n AA Jl^ \ qA'. S Akl� Sit akcia OA 10110-c "MA /Iovmq, Arj A�e �i ata `t 1 ��t41V DATE INSPECTOR �_ OF SOUTyo� V V S1 Z V r -- # # TOWN OF .SOUTHOLD BUILDING DEPT. '. 765-1802 INSPECTION j [ ] FOUNDATION 1ST - [ ] ROUGH PL13G. [ ] 'FOUNDATION°2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL T ] FIREPLACE &CHIMNEY [ ] -FIRE SAFETY'INSPECTION' [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION rl PRE C/O REMARKS: q3e&q�— o & ffoorr c( F A0�i___41�q0A"t'l . bt s /'e U o S-014 " �' /A DATE INSPECTOR �laaF SOUI,��# . TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: s DATE '?/ INSPECTOR Pacifico Engineering PC i Engineering Consulting 700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716 W-IG solar@pacificoengineering.com October 17,2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Joseph Burrascano Section-Block-Lot: 54-5-45.4 2120 North Sea Drive Southold, NY 11971 have reviewed the solar energy system installation at the subject address on October 17,2022.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that. the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer OF NEW y H PACO C/;�� 0� � t 1 f � ? U6618b Ralph�o og neer NY 066182/NJ 24GE04744306/FL 87297 D DEC 0 "► '�`i'�`' BUOAUdG OSM TroW)FSoMOLD FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION(IST) �a H ------------------------------------ C FOUNDATION(2ND) z � � o ROUGH FRAMING& - t PLUMBING . r INSULATION PER N.Y. y STATE ENERGY CODE -a 1 oy-V r FINAL v -' ADDITIONAL COMMENTS 211e c 0 -S 22. - fAid $1/0 -P 1ppJ vzzoe,m 4. rme 16 aq r!g -rnt LCZY ''a Z � rn ro H � z y t" H d b H COG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� Town Hal)Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 h 2. Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.jzov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only d E C E � Il v/J @ PERMIT NO. 9 Building Inspector: JUN 2 7 2022 Applications and forms,must be filled out in their entirety. Incomplete BUILDING DEP-r applications will not be accepted. Where the Applicant is not the owner,an TOWN OFSOUTHOLI) Owner's Authorization form(Page 2)shall be completed. Date:6/23/22 OWNER(S)OF PROPERTY: Name:Joseph Burrascano SCTM #1000-54.-5-45.4 Physical Address:2120 North Sea Drive, Southold, NY 11971 Phone#:(631) 495-2010 1Email:burraj69@gmail.com Mailing Address:2120 North Sea Drive, Southold, NY 11971 CONTACT PERSON: Name:Sue Estabrooke/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue@longislandpowersolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Pacifico Engineering, PC Mailing Address:700 Lakeland Ave, Suite 213, Bohemia, NY 11716 Phone#:631-988-0000 Email:solar@pacificoengineering.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ®Other Proposed(33)panel roof mounted solar array.(13.2)kW System;(1)Generac PWRcell 18 Battery Back up $41,386.90 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No Inverter:(1)Generac X7602;Modules:(33)Hanwha Q.Peak Duo 400W;Support:Iron Ridge XR-100;(1)Generac PWRcell 18 Battery Backup. 1 e @ PROPERTY INFORMATION Existing use of property:Sin le Famil Dwellin Intended use of property: le Famll Dwellin -_-- 9___w __Y _9 ______ _.__ _—.9__J._.___y_^�_9 Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes @No IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a.Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances,or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are Punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizone Electrical/Lon Island Power Solutions Application Submitted By(print name): IgAuthorizedlAgent ❑Owner Signature of Applicant: r_ Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this rd \ a'J day of 1vhe_ ,202-1—. Not LYNN '�ETTE ESTABROOKE NOTARY-PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION Registration No.OlES6259997 Qualified'in'Dutehess County (Where the applicant is not the owne ) Commission Expires April 16,2024 I, �c�se�V��ur S oSLQ�O residing at a-\, Michael Catizone/Long Island Power Solutions do hereby authorize to apply on my beh f to the n of Southold Building Department for approval as described herein. a ?//�-12v ZZ. Owne s Signature Date Print Owner's Name 2 L41 h, �o•°Su��FF�i�oy 1'UVVN UN'SUU'1'liULll—13UlLll1N(x llL+YA1Z'1'1V1F;N 1' lip Lis �2'� '1'ownHall Annex 54375 Matn.Roadl'. U.Box 1179 Southold, NY 11971-0959 �y • old 'Telephone (631) 765-1502 https://www.southolctowmy.gov Floodplain Development Permit Application PROPERTY INFORMATION: Flood Zone: A 1-2, FIRM Panel: SCTM#1000- &41-. Address: 2-1 U eeUOV V14 SI- - yz tV� City: � 0 1 u 1 Zip: t �q -7 l CONTACT PERSON: Name: J XSvA N-0 Phone#: Mailing Address: ?�-Zz NO Le—A 1'>� S0 uTl--V b'f-) PROJECT DESCRIPTION: S'o 10,r VX SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity FEOINon-residential sidential(1 to 4 families) ❑New structure sidential(more than 4 families) ❑ Demolition of existing structure mbined use ❑ Replacement of existing structure ❑Relocation of existing structure ❑ Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) ❑Alteration to existing structure ❑Manufactured Home Other: ❑Located on individual lot ❑Located in manufactured home park SECTION B;OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation(not related to a structured development) 17 Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to.the best of my knowledge the information contained in this application is true and accurate.I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein.If revoked,all work must cease until permit is re-issued.Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): � '� 2 �� Signature of Applicant: ' Date: g I Z Z O; ,fFO( TOWN OF SOUTHOLD—BUILDING DEPARTMENT N x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 hiips://www.southoldtom=.aov Floodplain Development Permit Application PROPERTY INFORMATION:FFlood Zone: FIRM Panel: SCTM#1000-54.-5-45.4 Address:2120 North Sea Drive city:Southold zip:11971 CONTACT PERSON: Name:Sue Estabrooke Phone#:631-348-0001 Mailing Address:2060 Ocean Avenue, Ronkonkoma, NY 11779 PROJECT DESCRIPTION: Proposed(33)panel roof mounted solar array. 13.2 kW System.(1)Generac PWRcell 18 Battery Backup SECTION A;STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity 8 Residential(1 to 4 families) ❑New structure ❑Residential(more than 4 families) ❑Demolition of existing structure ❑ Combined use ❑ Replacement of existing structure ❑Non-residential ❑Relocation of existing structure ❑ Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) R Alteration to existing structure ❑Manufactured Home ® Other: Roof Top Solar&Battery Backup ❑ Located on individual lot ❑ Located in manufactured home park SECTION B: OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration(attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the,best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert,of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name) %A ichW CatiZone Signature of Applicant: Date:7/29/22 _SgF �7,, f I ; Q B LDING DEPARTMENT- Electrical Inspector Y d•��V r. TOWN OF SOUTHOLD Town` all Annex- 54375 Main Road - PO Box 1179 _�, _ ., gUlt o�►�r oEp?. Southold, New York 11971-0959 TO\N�,OF�nUTl�ua l� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.-gov-!--!!-seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Catizone Electrical/Long Island Power Solutions i Name:Michael Catizone License No.: 36178-ME email: sue@longislandpowersolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (Ail Information Required) Name:Joseph Burrascano Address:2120 North Sea Drive, Southold, NY 11971 Cross Street: Hortons Lane Phone No.:(631) 495-2010 BIdg.Permit#: 1 email: burraj69@gmail.com ! i Tax Map District: 1000 Section: Block: S Lot: s BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(33)panel roof mounted solar array. (13.20)kW System;(1)Generac PWRcell 18 Battery Backup Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) {' Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: Inverter:(1)Generac X7602 Modules:(33)Hanwha Q.Peak Duo 400W;Battery Backup(1)Generac PWRcell 18 PAYMENT DUE WITH APPLICATION Request for Inspection FormAs '; i N iSCDHS REF#RI0-170033 SURVEY OF PROPERTY AT SOUTHOLD TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. 1000-54-05-45.4 SCALE 1- 30' APRIL 7,2015 MAY 12,2015(B.O.H.) FEBRUARY 14, 2017(PROP?HOUSE) \ MARCH 1,2017(CERAFICAAONS) I ♦ A�Q' / MARCH 30,2017(REWMONS) TEST HOLE DATA 11 4 Cy AUGUST 09,2017(1L7P0. &MONUMENTS) 17(RELIMONS) EL wn rs L"� / 3`L�Ao �p OCTOBER fSEPT 2017(STORY WATER MANAGMENT) EW)-LOAMY SAND SV G �F F (STAKES D 5 SEV PALE BROWN FINE SAND SP I JmV O/, i Q Q� % 0 � FEBRUARY JANUARY 2018(FOUNDA7I0N LOCATION) - a• Q T FyFs NOVEt1BER JO, 2018(FINAL) PACE BROWN ANE TO COARSE SAND SW, WTD/l0i GRAVEL EL o.4• - ASti ?-f,, h O vJY 0+WASo TER W PALE BROWN FINf ro COARSE SAND SW O �♦ V'D SIS ,�4 Fj�, 1 -M los CRAM \♦ 2 Q•�\� o r F 9� P��y�yF k'4.4. ` N01E.•WATER ENCOUNTERED 4.X BELOW SURFACE j ��Q �. µ a¢' / \ O 0 \� \o�o�,i 788 / �� 3PJg♦PO 3P� of Or may/ X30 � N.t'`Y°i �\\ \\2, / d„ JOJ�O - _ /, 4� 0✓OUB�� c ao mac / w D,m a,6c ,�,p•�f�a / / \O SEPTIC LOCATION '� a♦- U Teo /°+� ,A ryy ' ys / 0- W0,A. ,B. Sr 26' 49' Lp 1 44' 61' 4',} / 2 °� LP 2 41' 62' // a 41 y4 LP 3 38' 66' LP 4 35' 68' LP 5 50' 69' J o?\ /'O ''a 01 LP 6U52- 7.1- KEY ti ♦ \ / `/-�)O LP STSs, \♦♦ % v LP 9 REBAR IP0 -IIELI- A -STAKE y� ♦\ �� �o� f9 -TEsr HOLE DO ? • =PIPE 20 10 CERTIFIED To ■ =NONUMENT .13 •��' \ STEWART TITLE INSURANCE CONFANY TITLEJOSEPH. BURRASGANO SJR v ND FLAG . DONA BURRA5LANO m,=U17LITRUTY POLE -HYDRANT /a ,Q\- K ySPtE OF R'clyYq, � c EU VAIKM'S ARE REFERENCED TO NAVD'88 DAMN. ' QJO mn �e1 /mn0/m-wffh Me STANDARDS FOR APPROVAL AND CONSTR(/CRQ4 OF p SUBSURFACE SEWAGE DISPOSAL SYSTEMS FOR SINGLE FAWLY RESIDENCES are will Old,by Ne-d/ff.-sat f"th-th mrd-the p-If to / `? 3 UG NO. 49618 NYAL�L / �G AREA= 40,903 SO. FT. PECONIC RS,P.G AYaWNY ACTERARON A7 01V LA N X Pr SURVEY IS A N 7209 N B S£CRON 72090F TH£NEW J �� (631)765-5020 FAX(831)785 1797 CERT STATE EDUGIRON RE AUD F As PER AP AND COMES z ALL P.O. BOX 909 COPIES SCAR HEREaN ARE VEAL OF TMS MAP AND COPIES THEREOF ONLY/F SAID MAP OR 12J0 TRAVELER$7REET COPIES BEAR THE IMPRESSED SEAL of THE SURVEYOR{THOSE SIGNATURE APPEARS NEREaL / Q- SOUTHOLD,N.Y. 11971 15-118 r To search Licensed Contractors,click here. Home Environmental Quality Create•an Application Record H-53562: Home Improvement License Record Status:Active Expiration Date:06/01/2024 Record Info v Payments. Custom Component Work Location 2060 OCEAN AVENUE.RONKONKOMA,NY 11779 View Additional Locations, Record Details Applicant: Licensed Professional: MICHAEL 3 CATiZONE MICHAEL CATRONE Birth Date:09105/1979 LONG ISLAND POVIER SOLUTIONS INC Suffolk County,Dept.of Labor,Licensing&Consumer Affairs i VASTER ELECTRICAL LICENSE Name MICHAEL CATIZONE Business Name I This certifies that the bearer is duly licensed LONG ISLAND POWER SOLUTIONS INC by the County of suffaik License Number:ME-53560 Rosalie Drago Issued: 06/0612014 Commissioner Expires: 06/01/2024 I f Suffolk County DOPI.Of Labor,Licensintl S.CamsurTa,-�-r.Affairs t•3�.5TEfR Irl-�Gl`f?ILfsL L=C�"i"�`—m i Na rrio f b,lol-tAEL J CA1`tf0N= I fide CorIfflop Ural flit t.-caf-of is dcrp r �ri1 Or�:orw E tf•a�T,4:ta sr _t^p t by lre Isiconse Murnber ME-361%8 flaan.nl10Otago Issued; 121101rZ100A Co+n".1tintlw, bxpinn: 12i01/2f022 r r QSYOTATE RK workers'Compensation CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured LONG ISLAND POWER SOLUTIONS INC D 6BA NEW YORK 0 OCEAN AVE OWER SOLUTIONS 2 6313480001 RONKONKOMA,NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 27-1175107 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold � P Y 53095 Route 25 3b.Policy Number of Entity Listed in Box"1 a" Southold, NY 11971 R97411-000 3c.Policy effective period 1/1/2015 to 8/26/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as desc d above. Date Signed 8/27/2021 By bA- 44122it (Signature of Insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that Insurance carrier) Telephone Number (212) 355-4141 Nameand-ritle SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note. Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 11111111111°°1°1°1°°1°1°111111°�!°111°111111 Client#: 83393 LONGISL15 ACORD,,., CERTIFICATE OF LIABILITY INSURANCEDATE(MMIDDIYYYY) 2/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER COONNTACT Commercial Support Edgewood Partners Ins.Center PHONE 63190-9700 FAX 40 Marcus Drive (AICE-MNo Ext): AIC,No): 631-390-9790 3rd Floor ADDRESS: NECertificates@epicbrokers.com Melville,NY 11747-2647 INSURER(S)AFFORDING COVERAGE NAIC# INSURERA:Southwest Marine&General Ins Co 12294 INSURED INSURER B: Long Island Power Solutions, Inc. INSURERC: DBA New York Power Solutions 2060 Ocean Avenue INSURER D: Ronkonkoma, NY 11779 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DDIYYY MM/DD A X COMMERCIAL GENERAL LIABILITY PK202200020693 2/28/2022 0212812023 EAAqCCry��HHq OCCURRENCE $110001000 CLAIMS-MADE ®OCCUR PREM s`0(aoNccu ence $300 OOO X PD Ded:5,000 MED EXP(Any one person) $10,000 X Contractual Liab. PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY®ECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ A AUTOMOBILE LIABILITY PK202200020693 2/28/2022 02/28/202 Eaa acadel tSINGLE LIMIT 1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNEDSCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X AUTOS ONLY X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY Per accident A X UMBRELLA LIAB X OCCUR EX202200001789 2/28/2022 02/28/202 EACH OCCURRENCE $5,000,000 REXCESS LIAB CLAIMS-MADE AGGREGATE $5,000,000 DED I X RETENTION$10000 $ WORKERS COMPENSATION SER OTH- AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE Y 1 N E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? F N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S3438616/M3437780 LJACO N Y S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 271175107 118. LOVELL SAFETY MGMT CO.,LLC 1 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LONG ISLAND POWER SOLUTIONS INC TOWN OF SOUTHOLD 2060 OCEAN AVENUE 53095 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2467 078-8 539135 04/01/2022 TO 04/01/2023 03/08/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2467 078-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS:/IWVVW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT MICHAEL CATIZONE VICE PRESIDENT JOSEPH MILILLO TWO OF TWO OFFICERS LONG ISLAND POWER SOLUTIONS INC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,ISURANCE FUND UNDERWRITING VALIDATION NUMBER: 396794370 11111111111111010 1111111111 0�0001100001021106564u�1�11�����1 Form WC-CERT-NOPRINT Version 3(081292019)[WC Policy-24670788] U-26.3 198 [00000000000102106564][0001-000024670788][##Z][15840.36][CerLNoP-073T 1][01-00001] IWWorkers' CERTIFICATE OF ATE Compensation NYS oIVORKERS' COMPENSATION INSURANCE COVERAGEhoard 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Catizone Electrical Inc 631348-0001 060 Ocean Avenue Ronkonkoma,NY 11779 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 455213112 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Utica Mutual Insurance Company 3b.Policy Number of Entity Listed in Box"1 a" Town of Southold 4766763 53095 Route 25 Southold, NY 11971 3c.Policy effective period 07/01/2021 to 07/01/2022 3d.The Proprietor,Partners or Executive Officers are ❑ included.(only check box if all partners/officers included) © all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that 1 am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Leonard Scioscia (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 6/9/21 (Signature) (Date) Title: Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier: 631-390-9700 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9.17) www.wcb.ny.gov Client#:83176 CATIELE DATE(MM/DDNYYY) ACRD. CERTIFICATE OF LIABILITY INSURANCE 9/23/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Commercial Support Edgewood Partners Ins.Center PHONE 631-390-9700 AX 40 Marcus Drive E--MATED Ext): A/C,No): 631-390-9790 ADDRESS: certificates@cookmaran.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC It Melville,NY 11747-2647 INSURER A:Utica Mutual Insurance Company 25976 INSURED INSURER B: Catizone Electrical Inc. INSURER C: 2060 Ocean Avenue INSURER D: Ronkonkoma,NY 11779 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE INggL WV R POLICY NUMBER POLICY EFF MM%IDm P LIMITS A X COMMERCIAL GENERAL LIABILITY Y CPP4784747 7/01/2021 07/01/2022 EEACHqq��OCCCURRENCE $110001000 CLAIMS-MADE ®OCCUR PREMISESaEocou"ence $100,000 MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY❑JE OT- F-1 LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ A WORKERS COMPENSATION4]66]63 7/01/2021 07/01/202 X PER OTH- AND EMPLOYERS'LIABILITY TUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE — E.L.EACH ACCIDENT $500,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Town of Southold is included as additional Insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971-0000 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S3241156/M3110173 JGRAS EW YORK Workers' (CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured CATIZONE ELECTRICAL CONTRACTING, INC. 2060 OCEAN AVE 646-383-3599 RONKONKOMA, NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,Le.,Wrap-Up Policy) or Social Security Number 45-5213112 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) TOWN OF SOUTHOLD Standard Security Life Insurance Company of New York 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD, NY 11971 R97483-000 3c.Policy effective period 1/1/2015 to 12/15/2022 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as descol7ed above. Date Signed 12/16/2021 By 41"at (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that Insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 4C or 513 of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. D13-120.1 (10-17) 111111111°!°!°!°1°11°1!°°°°�°11°!�°!�!i°!°!°1111111 LONG ISLAND ®W Em R 2060 Ocean Ave Ronkonkoma, NY 11779 �OLUTIOw631348-0001 1�I www.longislandpowersolutions.com June 23, 2022 TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Joseph Burrascano—(63 1) 495-2010 Project/Property Address: 2120 North Sea Road, Southold,NY 11971 Section/Block/Lot: 1000-54-5-45.4 Electrician/36178-ME: Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor/53562-H: LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Pacifico Engineering—700 Lakelalnd Ave, Ste 2B,Bohemia,NY 11716-631-988-0000 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings & Specs • Liability, Disability & Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Sue Estabrooke, Permit Manager Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 sue@Gopowersolutions.com Go Green Save Green Firefox qW� about:blank FOR ALL MARMGON LEFT SIDEINVERTER 1W OWER (8)Q.PEAK PV LINK IN2AM1GT11YwFORNOMERIRIS UNDER 1W METER SMOAV/G THAM FOR HOLM:RUMS OVER 107 1 • SOLUTIONS DUO BLK 1 UNEt NERAC _ 1+)LINE SMACOPUTcNw 32 A RONKO�hN1AAVENUE.1 ML-G10+400 (1)NEUTRAL POWERCORE N]wIl01BR10IR11CroyA,E210 PERCIRGROUND T X7602 — -- (63) W �I-ORItPW 30A 7AW10 BURRASCANO (8)Q.PEAK PV LINK S� 30A e"�� uNEswETAP 00 NOT RELIDCATIETM RESIDENCE DUO BLK 30A owTcuaolrDevlce ML-G10+400 30A 50A 2120 NORTH SEA DRNE SERVICE SOUTHOLD,NY 11971 MAIN S 20ER 631-495-2010 S:54 B:5 L:45.4 60A FUSED SERVICE (8)Q.PEAK PV LINK CT PROJECT DATA:ma DUO BLK K,E M GENE�>� YOOLLES 13314PEAK000BLK YLGIO•MMI (2)40A FUSES RAVY w RIDGE w°1w WATTAGE 132W 1 +400 WARNING R O TYPE COMVOS@ 14 SHNCAES I• -3 ROMEX FM LaG USE w IN 1°OA°fMl fASTE>ER USE YI6'DIA.5'LAGS ELECTRIC SHOOK HAZARD °A"0°�E�PMq�LL1° A16 AWG THWN (9)Q.PEAK PV LINK TERMINALS ON THE LINE AND (1)LINE 1 LOAD SIDES MAY BE ENERGIZED (1)LINE 2 DUO BLK —.•- IN THE OPEN POSITION (1)NEUTRAL OR SM PA T1oNPA� RuBPANEL (1)4 8 GAUGE EGC ML-G10+400 IN 11•PVC CONDUIT #6/3 ROMEX WIRE —_ (1)UNE 1 PWRceII 18 (1)LINE 2 (1)NEUTRAL (1)EGC IN 1i'PVC CONDUIT 125A RATED BUS W/ A A 5011 ESSENTIAL LOAD SUB PANEL THREE POWER SOURCES CRIRCAL LOAD CIRCUIT D ° `z M10VNA 1 P RUPof6NTOli lffT MIAAVIVASTAOUMTOROW IMA V IS 6 A 1►r/I ROYR11 CN W f _ nITJRV5A/Ptd1191OW10/GTACIRIS SHURESTART EQUIPMENT' - IZ IZII ZA2P-]S MCO1®rBlO1RODOR i33)Q.PEAK DUO BLK ML-GIM 100 MOTEL A AC UNIT SMM GENEAAC RVRCELL 18 - 1Mt2w'v �BITa9R®AAIOq SSIB16-32 ALTE9 T%K:a Twsooa�vr E>,cvr RTA GENERAL X76021NVERTER - � IA Gwnmoel uanrc ucflsm�aT3s�unniuN. PHOTOVOLTAIC „'3r'r»�w,..,GwG rPEA=GE„.,r,G GENERAC SAMA FOR AC 2IP°Ir Ho11EafT1o; SFIURESTART-MOTEL R SS181" 100A SUBPANEL DATE:4/26/2022 -INTERCONNECT CAPABLE SMOKE DETECTOR MAIN SOLAR SYSTEM CDHESICG�N��BY:MW - -SURFACE MOUNT UGHTRATURE AC DISCONNECT REEVI90NSBY:XX GENERAC As-Built -FIRE RATED DOOR CONSTRUCT)ON OF ELEVATED CLOSET _-----------------...--'-- DECEMBER 11,A71 NOTE: 2020RESOBIIMLCODEOFNEWYORKSTATE,2020B6R;YCOMMATIDNCODEOFNEWYORKSTATE WIRING , E 1 3 ALLNGTOMEETTHE2017NECAND2020ENERGYCODE TOMOF30URIOLDCODE.SITNATOIALELA LECIRI000DEASCE7.It ELECTRICAL PN 6DA FUSED SERVICE RATED DISCONNECT t� 1 of 1 12/16/2022, 12:48 PM S Q-e U I v� Lr 3 FOR ALL WIRING ON LEFT SIDE OF INVERTER METER , OW E R (8)Q PEAK PV LINK 112 AM THWN FOR HOME RUNS UNDER 100' • 110AWG THWN FOR HOME RUNS OVER 100' . . SOLUTIONS DUO BLK (1)UNE I GENERAL O (1)LINE 2 RA7�AC OitFt'J-CUR!I7�2 ONK OCEAN AVENUE, ML-G10+400 (1)NEUTRAL POWE7RCORE p rypKy RONKO)348-0 NV 11779 (1)GROUND X I UOZ (631)348-0001 79 PER CIRCUIT IN 1"OR 1}"PVC CONDUIT �+ 30A TRW 10 Ammin B U R R A S C A N 0 PV LINK N K R51 LINE SIDE TAP (8)Q.PEAK 30A rNVERiERwrwrcolrMEcnoN DUO BLK 30A Do NOT RELOCATE THIS RESIDENCE OVERCURRENT D"E ML-G10+400 30A 50A 2120 NORTH SEA DRIVE SOUTHOLD,NY 11971 MAIN SERVICE 631-495-2010 60A FUSED SERVICE- 200A S:54 B:5 L:45.4 RATED DISCONNECT (8)Q PEAK PV LINK PROJECTrENERA:#225388 INVERTER'.GENERALXDUO DUO BLK MODULES RONRIDGKDUO BLK ML G10a 000 (2)40AFUSES RACKING IRON RIDGE%R100 WATTAGE'.13,200 ML-G10+400 �- ROOF TYPE COMPOSITION SHINGLES L&WA R N I N G WIND LOAD,-546PSF CI i FASTENER:USE 5/16'DIA..5"5"LAGS ELECTRIC SHOCK HAZARD . BACKUP GENERAC PWRCELL IS TERMINALS ON THE LINE AND ! V1J1 PV LINK LOAD SIDES MAY BE ENERGIZED G rHWN (9)Q.PEAK NE1 AC DISTRIBUTION PANEL DUO BLK IN THE OPEN POSITION (ml) NE2 OR SUB PANEL UTRAL ML-G 10+400 AWG EGC PVC CONDUIT THWN1PWRcell18 LINE GENERAC As-Built TRALVC CONDUIT 100A CRITICAL LOAD PAMMUll ZEN Ri, A a SUBPANEL •1 4 w • CRITICALLCADGRCUIT D ,• • , 2 O - (f)120VZlN1 PREFRIGERATORLr3T U - (1)120 V 20A1 P REFRIGERATOR RIGHT (1)120 V 15 Al P VAR CIRCUIT N EQUIPMENT: ,�(.1j1�m_v iSAIP OOMPurER CHARGING CIRCUITS SHURESTAR7 p X33)CREAK DUO BLK ML-G10-400 - 1�Lp9123gy2SA - •" rr MOTEL# AC UMT SMM 1 (No SA KLM -ECTRCHEAT)AIR HANIXFR MD00R UNR SSi816-32 -GENERAL PWRCELL IB ���a���Tl -GENERAC X7602 INVERTER rrnarnnuly oP nus ucxaa�crvT excPrr nv A LIIENSID PRO}3310 5 D1.EGAL -GENERAC SMM FOR A/C PAPER s¢E.i r.v fel 6I SHURESTAR7-MOTEL#SSIB16-32 PHOTOVOLTAICC DATE:4/26/2022 -100A SUBPANEL �-•� -INTERCONNECT CAPABLE SMOKE DETECTOR MAIN SOLAR SYSTEM . ` , 1 DESIGN CHECKED BMW SURFACE MOUNT LIGHT FIXTURE AC DISCONNECT / Gi 1 1 S (!, REVISIONS: FIRE RATED DOOR r'1/V -CONSTRUCTION OF ELEVATED CLOSET - -- — A NOTE: 2020 RESIDENNIL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NAT04AL ELECTRIC CODE ASCEM ELECTRICAL PLAN JE—1 y 60A FUSED SERVICE RATED DISCONNECT powered by DUO • YR �. Q TOP BRAND PV eulor[ ' Warranty 2021 a CELLS T BREAKING THE 20%EFFICIENCY BARRIER nn/II Illlnllll�IIS Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of v�? the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY (?; Optimal yields,whatever the weather with excellent low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTM'. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 20 A RELIABLE INVESTMENT �� � Inclusive 25-year product warranty and 25-year linear performance warranty2. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) f See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS f ' MECHANICAL SPECIFICATION Format 74.0 in x 41.1 in x 1,261n(including frame) (1879 mm x 1045 m m x 32 mm) 4 oµ6 9 m1) -- 41.8'(1098 mm) 15.5'(395.5 mm) Weight 48.51bs(22.Okg) Front Cover 0.13 in(3.2mm)thermally pre-stressed glass with anti-reflection technology Back Cover Composite film 39.1'(996 mm) Frame Black anodized aluminum llo4smm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells 411' Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),I1367,with bypass diodes =49.2'(zsomm) Cable 4mm2Solarcable;(+)2t49.2in(1250mm),H2:49.2in(1250mm) ,=;1i 9.omi°.o.hw. 4.M ,ftg a (DETAR A) Connector Steubli li 1068 I - �V-126'(32 mm1 OEfAxA H-1r 098'(14.511)I10'3Y ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS.STC- ` Power at MPP- P.m [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 1104 11.07 11.10 11.14 11.17 3 Open Circuit Voltage= Vcc [V] 45.19 45.23 4527 45.30 45.34 E _ 5 Current at MPP imm [A] 1059 10.65 Y 10.71 10.77 10.83 Voltage atMPP Vmpp [V] 3636 3662 36.88 37.13 37.39 Efficiency- 9 [/] >_19.6 >_19,9 >_20.1 >_20.4 x20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING COND!T`C'.3.:'.!C' Power at MPP PMm [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 - 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 4262 42.65 42.69 42.72 42.76 _c _ 2 Current at MPP imm [A] 8.35 8.41 8.46 8.51 857 _ Vmpp [V] 34.59 3481 35.03 35.25 35.46 'Measurement tolerances P_±3%,Isc:Voc±5%at STC:1000 W/ri 25±2°C,AM 1.5 according to IEC 60904-3''800 W/M2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE -� �OCLS Atleast 98%of nominal powerdurin '_' -T-----r - ----n----- .. first year.Thereafter max.0.5% z ----------------------------- degradation per year.At least 93.5% of nominal power up to 10 years.At - ' least 86%of nominal power up to �� " ----------- 25 years. f 90 __r_____r____-_____y_____-j a =z ' z 0 � All data within measurement toleranc- es.Full warranties in accordance with saa jos Sao rae ie90 the warranty terms of the Q CELLS o f sales organisation of your respective ie9.+ouMCE(wr'9 r9 a a a a country. --F`- Typical module performance under low irradiance conditions in o comparison to STC conditions(25°C,1000 W/ml) e 40 TEMPERATURE COEFFICIENTS 0 c [%/K] 004 - _ _ - �cef6cientofVzc R [%/K] -0.27 y [%/K] -0.34 eOperating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN ° a IV] 1000(IEC)/1000(UL) y :roar;ie classification Class 11 o ',fa,-_-S es=,5= q [ADC] 20 =_-2 _. zcss>; ANSI/UL 61730 TYPE INS Cesq,_ca .c...;- [lbs/ft2] 75(3600 Pa)/55(2660 Pa) =_.'nperature -407upto+185°F c "a=_`es•_�s� =.s- [Ibs/ft2] 113(5400Pe)/84(4000Ps) - "- (-40°Cupto+85°C) o "m 3See Installation Manual cl a U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION p o lity CE-compliant, Qu �jO[ �[ r•j 53 Quality Controlled PV-TUV Rheinland, aj IEC 61215:2016,IEC 61730:2016, / U.S.PetenWo.9,993,215(soler cells), SA® ( 76.41n 43.3in 48.01n 1656lbs 24 24 32 o OCPV Certification ongoing. Cr,,,US \ 1940mm 1100mm 1220mm 751 kg pallets pallets modules - u1 81)30 io>tmzz9zn m n N Nota:Installation instructions must be followed.Seethe installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAIL inquiry@us.q-celis.com I WEB www.q-cells.us GENERAC PWR -a GENERAC" PWR 7.6kW 10,11.4kW 30 PWRcell Inverter w/CTs and CT Adapter Model:APKE00014,APKE00013 Certification Model Reference: X7602,X11402 Solar-plus-storage is simple with the Generac PWRcell Inverter.This bi-directional,REbus-"- powered inverter offers a simple,efficient design for integrating smart batteries with solar.Ideal for self-supply,backup power,zero-export and energy cost management,the PWRcell inverter is the industry's most feature-rich line of inverters,available in single-phase and three-phase models. ADDITIONAL FEATURES • Single inverter for grid-tied solar with smart battery integration • Simplified system design:No autotransformer or battery inverter needed • User-selectable modes for backup power,self-supply,time-of-use and zero-export • Free system monitoring included via PWRview Web Portal and Mobile App AC OUTPUT; rr rrr14 MODELAPKE00013 DC INPUT MODELrrr •rAPKE00013 RATED AC POWER OUTPUT 7600 W 11400 W DC INPUT VOLTAGE RANGE 360-420 VOC 360-420 VDC AC OUTPUT VOLTAGE 120/240,10 YAC 120/208,30 VAC NOMINAL DC BUS VOLTAGE 380 VDC 380 VDC AC FREQUENCY 60 Hz 60 Hz MAX INPUT CURRENT 20A 30A MAXIMUM CONTINUOUS OUTPUT CURRENT 32 A,RMS 32 A,RMS REVERSE-POLARITY PROTECTION YES YES GROUND-FAULT ISOLATION DETECTION Included Included GROUND-FAULT YES YES ISOLATION DETECTION CHARGE BATTERY FROM AC Yes Yes TRANSFORM ERLE SS,UNGROUNDED YES YES THD(CURRENT) <2% Q% TYPICAL NIGHTTIME POWER < CONSUMPTION 7W <7W rC INPUT;BATTERY MODEL APKE00014 MODELAPKE00013 MAXIMUM CONTINUOUS POWER 8000 W 8000 W MODELAC OUTPUT BACKUP rrr14 MODEL APKE00013INTERNAL DC DISTRIBUTION BREAKERS 4X 2P30A 4X 2P30A RATED AC BACKUP POWER OUTPUT 8000 W 8000 W DC FUSES ON PLUS AND MINUS 40 A 40 A MAXIMUM AC BACKUP POWER OUTPUT 10000 W 10000 W 2-POLE DISCONNECTION YES YES AC BACKUP OUTPUT VOLTAGE 120/240,10 VAC 120/240,10 VAC AC FREQUENCY 60 HZ 60 HZ EFFICIENCY MODELrrr •rAPKE00013 AC CIRCUIT BREAKER 50 A 50 A PEAK EFFICIENCY 97% 98% THD(VOLTAGE) <2% <2% CEC WEIGHTED EFFICIENCY 96.5% 97.5 AUTOMATIC SWITCHOVER TIME <1 Seconds <1 Seconds TYPICAL NIGHTTIME POWER 30 W 30 W CONSUMPTION PowerGenerac .0 Hwy.59,Waukesha,WI 53189 Specifications ISLANDING' Yes GRID SELL Yes SELF CONSUMPTION Yes PRIORITIZED CHARGING FROM RENEWABLES Yes GRID SUPPORT-ZERO EXPORT Yes SUPPORTED COMMUNICATION INTERFACES CANbus.RS4854,Ethernet SYSTEM MONITORING PWRview Web Portal and Mobile App CRITICAL LOADS DISCONNECT' Yes MANUAL INVERTER BYPASS SWITCH Automatic WARRANTY 10 Years SAFETY UL1741 SA,CSA 22.2 GRID CONNECTION STANDARDS IEEE1547.Rule 21,Rule 14H EMISSIONS FCC part15 class B WIRE GAUGE RANGE 10-8AWG TOTAL AC KNOCKOUTS X SIZE 2"x 0.75".2 x 1" TOTAL DC KNOCKOUTS X SIZE 5"x 1" DIMENSIONS(L.W,H) 24.5'x 19.25'x 8" WEIGHT 62.7 lb COOLING Forced convection NOISE <40 dBA OPERATING TEMPERATURE -20 to 50°C' PROTECTION RATING NEMA 3R BATTERY TYPES SUPPORTED PWRcell battery module MODULE STRING SIZE PER PV LINK OPTIMIZER 2-9 PV modules MAXIMUM RECOMMENDED DC POWER FROM PV 10kW(1O),15kW(30) BATTERIES PER INVERTER Up to 2 '30 inverters offer islanding for 10 loads, Modbus, 'Reduced power at extreme temperatures Specifications subject to change without notice. Generac Power Systems,Inc. GE ISI E RAC S45 W29290 Hwy.59,Waukesha,WI 53189 www.Generac.com 1-888-GENERAC(1-888-436-3722) Part No.A0000528185 REV A ZrA# I RON RI DGE Roof Mount System solar's toughest roofs IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rails — XR10 Rail XR100 Rail XR1000 Rail Internal Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear& black anod.finish Clear& black anod.finish Clear anodized finish Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs T Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear& black anod.finish 4"and 7" Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs 54 Accessories i Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. • Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps • Mill & black stainless Swivels in any direction UV-protected polymer Free Resources -- Design Assistant A NABCEP Certified Training Y Go from rough layout to fully �•► Earn free continuing education credits, engineered system. For free. A. ,Ah, while learning more about our systems. ^ _ 0 2014 IronRidge,Inc.AJI rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1,42 J OENERAC VWROM GENERAC PW PWRceIl Battery Cabinet(Ordering SKU APKE00007; 3.OkWh PWRceIl EX Battery Module Model O r Ordering SKU G0080000 2.85kWh PWRceIl DCB Battery Module Model#BJ-DCBOSZKAX(Ordering SKU:A0000391219t The PWRceIl°Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need,small or large.No other smart battery offers the power C US and flexibility of PWRceIl.Whether for backup power or smart energy management, PWRceIl has power and capacity options Intertek for every need,without sacrificing flexibility or function. PWRceIl BATTERY CABINET DESIGN FEATURES & BENEFITS The PWRceIl Battery Cabinet allows system owners Connect 2 PWRceIl Battery Cabinets to a single PWRceIl the flexibility to scale from an economical 8.6kWh to a Inverter for up to 36kWh of storage massive 18kWh by installing additional battery modules gest-in-class battery backup power to the PWRceIl Battery Cabinet.When needs change,an existing PWRceIl Battery Cabinet can be upgraded with Plug-and-play with PWRceIl Inverter and PV Link" additional modules.Use the graphic below and the chart Time-of-use(TOU)and zero-export ready on the back of this sheet to understand what components you need for your chosen PWRceIl configuration. Residential and commercial application ready. • Outdoor-rated battery cabinet available as an upgrade BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY rwrara + / • l /` / OR M6 M5 M4 M3 PWRceIl 6x Battery Module 5.Battery Module 4x Battery Module 3x Battery MoculE Battery Cabinet -Module Spacer Ka Module Spacer Ct ' + PWRce6 Battery Battery Cabinet Module Module sack 1-cl PWRcell Spacer Kit x5 Battery Cabinet xt Frau Panel ,.....,. Specifications ,.,..,..........,.,..,....,...,........,.........,.,.,.....,,,....,.,.........,.,............,.,...........,....,...,,,.....,......,...,. PWRcell BATTERY CONFIGURATIONS BATTERY MODULE SERIES: EX DCB BATTERY MODULES: 3 4 5 6 3 4 5 6 USABLE ENERGY: 9 kWh 12 kWh 15 kWh 18 kWh 8.6 kWh 11.4 kWh 14.3 kWh 17.1 kWh AVG.AC POWER OVER COMPLETE DISCHARGE CYCLE: 3.4 kW 4.5 kW 5.6 kW 6.7 kW 3.4 kW 4.5 kW 5.6 kW 6.7 kW MAX.CONT.AC POWER 4 40°C(104°F): 4.5 kW 6 kW 7.5 kW 9 kW 4.5 kW 6 kW 7.5 kW 9 kW PEAK MOTOR STARTING CURRENT(2 SEC) A,RMS 25 33 42 50 25 33 42 50 REbus"VOLTAGE INPUT/OUTPUT: 360-420 VDC NOMINAL VOLTAGE: 43.2 VDC 46.8 VDC DC-DC ROUND-TRIP EFFICIENCY: 96.5% MAX.AMBIENT OPERATING 14 to 122°F 41 to 113"F TEMPERATURE RANGE: (-10 to 50°C) (5 to 45°C) RECOMMENDED AMBIENT OPERATING 32 to 104°F 55 to 86°F TEMPERATURE(FULL POWER)': (0 to 40°C) (13 to 30"C) MAXIMUM INSTALLATION 9834 ALTITUDE-FT(M): (3000) DIMENSIONS, 22"x 10"x 68" LxWxH-IN(MM): (559 x 254 x 1727) WEIGHT,ENCLOSURE-LB(KG): 111(50) WEIGHT,INSTALLED-LB(KG): 282(128) 340(154) 397(180) 454(206) 276(125) 331(150) 386(175) 441(200) WARRANTY-LI-ION MODULES: 10 Years,(7.56MWh) WARRANTY-ELECTRONICS 10 Years AND ENCLOSURE: COMMUNICATION PROTOCOL: REbus"DC Nanogrid" COMPLIANCE: UL 9540,UL 1973,UL 1642,CSA 22.2#107.1 'Performance maybe limited outside of recommended operating temperature range PWRcell ACCESSORIES PWRcell MODEL BUILDER The PWRcell Battery Cabinet(APKE00007)is rated for indoor use only.If installing outdoors,the PWRcell Outdoor Rated Battery Cabinet(APKE00028)must be used.Inside of the PWRcell IR M3 EX PWRceII Battery Cabinet,battery modules are stacked two deep T T T on three levels,allowing for up to six modules to be connected in series.You can upgrade an existing PWRcell Battery Cabinet by IROndoorRa" 3Modules DCIS OR(Outdoor Rated) 4 Modules EX adding Battery Modules and a Module Spacer(APKE00008). 5Modules A Module Spacer is only required for battery configurations 6 Modules with an odd number of modules(i.e.3 or 5). Samp;e Model Name:PWRcell IR M3 Ex Generac offers a convenient PWRcell Battery Upgrade Kit (APKE00009)to help replace lost or misplaced hardware. Note.When adding modules,be sure all modules within an individual cabinet are of the some series type(i.e.EX or DCB). Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 www.Generac.com 1888-GENERAL(436-3722) GENERAC A0000528139 REV F 2020 Generac Power Systems.All rights reserved. Specifications are subject to change without notice. APPROVED AS NOTED COMP YWiTH ALL CODES OF DATE7'2& _a B.P. # S 1aa NEW YORK STATE &TOWN CODES F EE's BY_JAI& AS REWRED AND CONDITlOI +E NOTIFY BUILDING DEPARTMENT AT JUTHOLD TQWi 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED SOUTTI'IOLDTN1 FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, St1UTHOLD TOIN35 ". STRAPPING, ELECTRICAL&CAULKING 3. INSULATION DEC 4. FINAL-CONSTRUCTION&ELECTRICAL MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION,SHALL MEET THE nit REQUIREMENTS OF THE CODES OF NEW �L�o�ZONA YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH CHAPTER 1146" FLOOD DAMAGE PREVENTION SOUTHOLD' TOWN CODE. ELECTRICAL INSPECTIOM IIEGUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS'OF THE d (,5coilmc+ mush be,-- CODES OF NEW YORK STATE. IC)Cctf(fd oui51de labs ,�aa�t ou mqu� -For -PWR ou" I w3wo ;lcifico Engineering PC _ Engineering Consulting 700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716 i G c solar@pacificoengineering.com June 22, 2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Joseph Burrascano Section-Block-Lot: 54-5-45.4 2120 North Sea Drive Southold, NY 11971 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B C D Mean roof height 18.0 ft 18.0 ft 15.0 ft 15.0 ft Pitch 23 degrees 23 degrees 23 degrees 24 degrees Roof rafter 2x8 Truss 2x8 Truss 2x8 2x8 Rafter spacing 24 inch on center 24 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 7.9 ft 7.9 ft 11.4 ft 11.3 ft Rafter span max allowable 13.8 ft 13.8 ft 18.5 ft 18.5 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category Load,Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A B 20 130 33 613 SS 5/16"dia lag bolt,5"length B 33 613 SS 5/16"dia lag bolt,5"length C 33 681 SS 5/16"dia lag bolt,5"length D 33 681 SS 5/16"dia lag bolt,5"length Weight Distribution OF INSarray dead load 3.5 . �plA pQ�'� load per attachment 65.0 Ib The subject roof has 1 layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. t � Ralph Pacifico, PE Professional Engineer n��, NY7297 AERIAL OWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 �� ..• ' (631)348-0001 3 BU RRASCANO RESIDENCE R-3 . . 2120 NORTH SEA DRIVE SOUTHOLD, NY 11971 631-495-2010 S: 54 B: 5 L: 45.4 O p R —5 PROJECT DATA: #225386 -�` INVERTER: GENERAC X7602 O MODULES: (33)Q.PEAK DUO BLK ML—G10+400 RACKING: IRON RIDGE XR100 R-1 WATTAGE: 13,200 ROOFTYPE COMP # MODULES (16) WIND LOAD:546PSF@01 0MPHGLES PITCH: 23° SHEET INDEX FASTENER:USE 5/16"DIA.5"LAGS BACKUP:GENERAC PWRCELL 18 AZIMUTH: 117° S-1 SITE PLAN S-2 DETAILS 3-5 E-1 ELECTRICAL PLAN p E-2 ELECTRICAL DETAILS E G1i�1 GC 6'-211 L-1 MOUNTING PLAN 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 R-3 # MODULES (10) Ph_631-988-0000 PITCH: 23° solar@pacificoengineering.com AZIMUTH: 2070 GENERAL NOTES www.pacificoengineering.com -FIRST RESPONDER ACCESS MAINTAINED 01F NFA` AND FROM ADJACENT ROOF. �Q��Qy� PAC�i�y0 VV -WIRE RUN FROM ARRAY TO CONNECTION IS 00 40 FEET. * 4: R-6 -COGEN DISCONNECT IS LOCATED # MODULES (4) ADJACENT TO UTILITY METER. PITCH: 230 -LAYOUT SUBJECT TO CHANGE BASED ON �O u6g1,62 3 M AZIMUTH: 117° �n SITE CONDITIONS AT DATE OF INSTALL OF�SSlpN N D �l ALTERATION OF THIS DOCUMENT EXCEPT BY A NLICENSED PROFESSIONAL IS ILLEGAL N R-5 JUN 2 12029 PAPER SIZE 11"x 17'(ANSI B) cD # MODULES (3) ILEGEND DATE: 4/26/2022 CL I PITCH: 240 BUILDIt'K'IDEPT y DESIGN BY: MW AZIMUTH: 207° TOS" OF ' ` ® GROUND ACCESS POINT CHECKS REVISEE IONS: 0616122 N COGEN DISCONNECT ° ® UTILITY METER m FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, REPRESENTS ALL FIRE CLEARANCE MINIMUM OF 36"UNOBSTRUCTED AS PER TOWN OFSOUTHOLDCODE,2017NATIONALELECTRICCODE.ASCE7-16. SITE PLAN S.1 o INCLUDING ALTERNATIVE METHODS THE 2020 RESIDENTIAL CODE OF NYS UFO lronRidge XR 100 RailOWER SOLUTIONS 2060 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 4D (631) 348-0001 BU RRASCANO RESIDENCE '"'ate Flashing 2120 NORTH SEA DRIVE SOUTHOLD, NY 11971 `_.EmS C110M, 631-495-2010 • ,��_.. S: 54 B: 5 L: 45.4 InnlRidge 3CR too Rail -•� ,� PROJECT DATA: #226386 IronRidgeXR 100 Rail 5/16 x 5„ Stainless INVERTER: GENERAC X7602 __.._ Bolt MODULES: (33)Q.PEAK DUO BLK ML-G1O+400 Steel Lag Bolt RACKING: IRON RIDGE XR100 SOtdf Module ROOF 13,200 ROOF TYPE:COMPOSITION SHINGLES 3/8—t a X 3/4 WIND LOAD:-54.6PSF @ 140MPH HEX HE^E) ®ULT FASTENER:USE 5/16”DIA.5"LAGS 3/8_145 BACKUP:GENERAC PWRCELL 16 FLAMCM NUT 3-5/8 11 P61K EGcp ,I GENERAL NOTES- 700 Lakeland Ave, Suite 2B -L FEET ARE SECURED TO ROOF RAFTERS @ 80" O.C. Bohemia, NY 11716 AND 72" O.C. USING 5/16" x 5" STAINLESS STEEL LAG Ph:631-988-0000 BOLTS. solar@pacificoengineering.com www.pacificoeng ineering-com -SUBJECT ROOF HAS ONE LAYER. ®� -ALL PENETRATIONS ARE SEALED AND FLASHED. .�QN PACGc���'� v� n ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES R1 230 2"x8" 2"x8"@24"O.C. 19' 12" TRUSS �o 0661 ID oFESS10N N R3 23° 2"x8" 2"x8"@24"O.C. 19' 12" TRUSS N ALTERATION OF THIS DOCUMENT EXCEPT BY A C11 LICENSED PROFESSIONAL IS ILLEGAL N " O 11 I 1 1 11 11 PAPER SIZE:11"x 17"(ANSI B) R5 230 2 x 8"@ 16"O.C. 141-411 12 Q DATE: 4/26/2022 R6 240 2 x12" 2"x8"@ 16"O.C. 14'-4" 1 12" DESIGN BY: MW CHECKED BY: EE 0 REVISIONS:1 LS KO 616122 V VJ f4 7 IT1 DESIGNED AS PER ASCE 7-10 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, MODULES MOUNTED FLUSH TO ROOF TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7.16, DETAILS S-2 NO HIGHER THAN 6"ABOVE ROOF SURFACE FOR ALL WIRING ON LEFT SIDE OF INVERTER OWER (8) Q.PEAK PV LINK #12 AWG THWN FOR HOME RUNS UNDER 100' ' • ! • I METER SOLUTIONS #10 AWG THWN FOR HOME RUNS OVER 100' ! >f ON14EC-T Ai DUO BLK —Ell (1)LINE 1 GENERAC (1)LINE 2 R1a11 AlllO17J ILRr" , 32JA 2060 OCEAN AVENUE, ML-G10+ 400 (1)NEUTRAL POWERCORE �rss � p ; r, 240 0 RONKONKOMA, NY 11779 (1)GROUND X7602 (631) 348 0001 PER CIRCUIT IN 1"OR 11'.'PVC CONDUIT 30A 7.6kW 10 &WARNING BU RRASCANO (8) Q.PEAK PV LINK RS I!N 30A VT-iT R!:� rT�JTCONNECTION -- =T L RESIDENCE DUO BLKFul 30A OVERTREi NIDE C. E �J�lERw�RREE4T©EV'aGE 2120 NORTH SEA DRIVE ML-G10+ 400 30A 50A SOUTHOLD, NY 11971 MAIN SERVICE 631-495-2010 200A S- 54 B- 5 L- 45.4 (5) Q.PEAK PV LINK /'� PROJECT DATA: #225386 DUO BLK PHOTOVOLTAIC INVERTER: G3)Q.PE Q.PEAK V Y V MODULES: (33)Q.PEAK DUO BLK ML-G10+400 FL'] RACKING: IRON RIDGE XR100 M L-G 10+ 400 MAIN SOLAR SYSTEM ROOF TYPE CO ° ROOF TYPE.COMPOSITION SHINGLES WIND LOAD-54.6PSF @ 140MPH AMARNING AC DISCONNECT FASTENER USE 5/16"DIA.5"LAGS ELECTRIC SHOCK HAZARD BACKUP GENERACPWRCELLIB TERMINALS ON THE LINE AND 40A #6 AWG THWN PV LINK LOAD SIDES MAY BE ENERGIZED XJ (5) Q.PEAK (1)LINE 1 AC DISTRIBUTION PANELIN THE OPEN POSITION (1)LINE 2 OR SUB PANELP CPDUO BLKFul ______ _ (1)NEUTRALE11� �ML-G10+ 400 (,)EGc - , IN 14"PVC CONDUIT AWARNINGZ 700 Lakeland Ave, Suite'28 _ Bohemia_ NY 11716 #4 AWG THWN • SOURCES (1)LINE 1 SOURCES UTILITY BATTERY Ph: 631-988-0000 (4) Q.PEAK PV LINK PWRcell 18 (1)LAND PV SOLAR ELECTRIC SYSTEM INE @p g g (1)NEUTRAL solar acificoen ineerin com DUO BLK (1)EGC www.pacificoengineering.com FL I IN 11"PVC CONDUIT M L-G 10+ 400 100A CRITICAL LOAD P�QV P4Cho�c0.p SUBPANEL PV LINKID: (3) Q.PEAK CRITICAL LOAD CIRCUIT DUO BLK (1)120 V 20A 1 P REFRIGERATOR LEFT (1)120 V 20A 1 P REFRIGERATOR RIGHT + (1)120V15A1PWFICIRCUIT SHURESTART 466 2 ML-G1 0 400 (1)120 V 15A 1 P COMPUTER CHARGING CIRCUITS D EQUIPMENT: 11 208/230V25A2P-2.5 TON CONDENSER OUTDOOR UNI MOTEL# N � -(33)Q.PEAKDUOBLKML-G10+400 (1)208/230V15A 2P-2.5 TON AIR HANDLER INDOOR UNIT AC UNITSMM1 sl N -GENERAC PWRCELL 18 (NO BACKUP ELECTRIC HEAT) SS1B16 32 �'�— ALTERATION OF THIS DOCUMENT EXCEPT BY A N -GENERAC X7602 INVERTER LICENSED PROFESSIONAL IS ILLEGAL (0 -GENERAC SMM FOR A/C PAPER SIZE 11"x 17'(ANSI B) CL -SHURESTART-MOTEL#SS1616-32 DATE: 4/26/2022 N -100A SUBPANEL DESIGN BY: MW -INTERCONNECT CAPABLE SMOKE DETECTOR CHECKED BY: EE c -SURFACE MOUNT LIGHT FIXTURE REVISIONS:1 LS KO 616122 -FIRE RATED DOOR -CONSTRUCTION OF ELEVATED CLOSET m NOTE: ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE ° 60A FUSED SERVICE RATED DISCONNECT POWER LUTIONS 100 A CRITICAL LOAD PANEL AIR CONDENSER SMM 2060 OCEAN AVENUE, CRITICAL LOAD PANEL CIRCUIT LIST: RONKONKOMA, NY 11779 (631)348-0001 DC DISCONNECT (1)120 V 20A 1 P REFRIGERATOR LEFT EXIATING ELECTRIC GENERAC POWER CELL 18 - (1)120 V 20A 1 P REFRIGERATOR RIGHT rwo STORY SERVICE SUB PANEL BATTERY BACKUP - (1)120 V 15 A 1 P WIN CIRCUIT B U RRASCAN 0 W000 STRUCTURE (1)120 V 15 A 1 P COMPUTER CHARGING CIRCUUIT 3,�„ - (1)208/230 V 25A 2 P-2.5 TON HEAT PUMP OUTDOOR UNI RESIDENCE NEW LIGHT FIXTURE (1)208/230 V 15A-2.5 TON HEAT PUMP INDOOR UNIT NEW SOMOKE DETECTOR (NO BACKUP ELECTRIC HEAT) 1 GENERAC X7602 2120 NORTH SEA DRIVE INVERTER SOUTHOLD, NY 11971 MAIN ELECTRIC SERVICE PANNEL 631-495-2010 i BREEZEWAY < > S: 54 B: 5 L: 45.4 EXTEND LINE VOLTAGE WIRING / ABOVE CEILING IN BREEZEWAY kkk PROJECT DATA: #225386 ATTIC SPACE GARAGE FF-10,6• INVERTER: GENERAC X7602 MODULES: (33)Q.PEAK DUO BLK ML-G10+400 RACKING: IRON RIDGE XR100 WATTAGE: 13,200 ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-54.6PSF @ 140MPH 0 FASTENER:USE 5/16"DIA.5"LAGS BACKUP:GENERAC PWRCELL 18 - El'N EQUIPMENT: ENERGY SYSTEM SITE PLAN ;I -(33)Q.PEAK DUO BLK ML-G10+400 -GENERAL PWRCELL 18 BATTERY ENCLOSURE AND PLATFORM CONSTRUCTION: 7G!0 Lakeland Ave, Suite 2B Bohemia, NY 11716 -GENERAC X7602 INVERTER -GENERAL SMM FOR A/C • EXISTING GARAGE SLAB IS AT ELEVATION 10.6'AS PER PROPERTY SURVEY Ph:631-98&0000 -30A 600V DC DISCONNECT • BASE FLOOD ELEVATION IS AT 12-FT(AE-12) -100A SUBPANEL • MINIMUM ELEVATION OF ALL ELECTRICAL EQUIPMENT IS 14.0'(3.4'ABOVE GARAGE SLAB) solar@pacificoengineering.com -INTERCONNECT CAPABLE SMOKE DETECTOR 7'-4"X T-4"WOODEN PLATFORM TO BE CONSTRUCTED WITH A FINISHED FLOOR HEIGHT OF 2'-11" www.pacificoengineering_com -SURFACE MOUNT LIGHT FIXTURE -FIRE RATED DOOR ABOVE THE EXISTING GARAGE SLAB. s • FLOOR OF PLATFORM TO BE 5/8"PLYWOOD. CONSTRUCTION OF ELEVATED CLOSET A CLOSET WITH INTERIOR DIMENSIONS OF APPROXIMATELEY 3-FT X 4-FT IS TO BE CONSTRUCTED ON THIS PLATFORM TO HOUSE THE BATTERY,AND IS TO INCLUDE A FINISHED CEILING. Q•P�PH PAC,��CO,� • CEILING AND WALLS TO BE SHEATHED WITH 5/8"TYPE X GWB MINIMUM. • FLOOR INSIDE CLOSET TO BE CLAD WITH DURROCK OR EQUIVALENT FIREPROOFING MATERIAL. Q` O • FINAL FLOOR FINISH MATERIAL(IF DESIRED)IS TO BE INSTALLED BY OTHERS. • PAINTING(IF DESIRED)TO BE DONE BY OTHERS. 1 • INSTALL A STEEL FIRE RATED DOOR AND LOCKSET. • INSTALL STAIRS WITH 7"RISE AND 11"RUN(4 TREADS). • INSTALL RAILING FOR STAIRS AND PLATFORM LANDING. U661 2 3 0 INSTALL SERVICE LIGHT WITH SWITCH IN CLOSET. • INSTALL INTERCONNECTED SMOKE DETECTOR INSIDE CLOSET. ESSION cn • INSTALL DC DISCONNECT FOR BATTERY — N N ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL N BATTERY INSIDE CLOSET IS TO BE WALL MOUNTED WITH ITS LOWEST POINT ABOVE ELEVATION 14' PAPER SIZE:I1'x 17-(ANSI B) (5"ABOVE PLATFORM FLOOR). a DC DISCONNECT INSIDE CLOSET IS TO BE MOUNTED ATAN EASILY ACCESSIBLE HEIGHT DATE: 4/26/2022 o APPROXIMATELEY 4-FT ABOVE THE PLATFORM SURFACE,AND WELL ABOVE ELEVATION 14' DESIGN BY: MW • SOLAR INVERTER TO BE INSTALLED ON OUTSIDE WALL OF CLOSET,WITH ITS LOWEST POINT CHECKED BY: EE ABOVE ELEVATION 14'(3.4-ABOVE GARAGE SLAB) REVISIONS:1 LS KO 616122 U N IO QJ 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-16. BATTERY DETAILS E•2 0 k4DOWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 p BURRASCANO RESIDENCE 2120 NORTH SEA DRIVE p p p SOUTHOLD, NY 11971 p 631-495-2010 S: 54 B: 5 L: 45.4 PROJECT DATA: #226386 INVERTER: GENERAC X7602 MODULES: (33)C.PEAK DUO BLK ML-G10+400 R-1 R-3 RACKING: IRON RIDGE XR100 WATTAGE: 13,200 # MODULES (16) # MODULES (10) ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-54.6PSF @ 140MPH FASTENER:USE 5/16"DIA.5"LAGS PITCH: 230 PITCH: 23' BACKUP:GENERAC PWRCELL 18 AZIMUTH: 117° AZIMUTH: 207° Pc t - E 01'k G c P 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 14' 14'-4" Ph:631-988-0000 -4" solar@pacificoengineering.com www.pacificoengineering.com OF ke QP�pH PAc�'c�y�9 R-5 R-6 17' 14' 6 # MODULES (3) # MODULES (4) oA ass, ,L 11' 6 PITCH: 24° PITCH: 23OSI00 cn oN in s.5' ° AZIMUTH: 207° AZIMUTH: 117° N N ALTERATION OF THIS DOCUMENT EXCEPT BY A ° N 4' LICENSED PROFESSIONAL IS ILLEGAL CN 0 PAPER SIZE:11"x 17"(ANSI B) ID Q ■ SPLICE BAR 6 DATE: 4/26/2022 © PENETRATIONS 73 DESIGN BY. MW CHECKED BY: EE UFO 86 REVISIONS:I LS KO 616122 40MM SLEEVE 40 END CAPS 40 CONSUMPTION o MOUNTING PLAN CRITTER GUARD 300' L.'� T y GENERAC� Installation Manual Generac PWRcell® Battery 0 0 0011031 AWARNING Loss of life.This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: https://register.generac.com/ 1-888-G ENERAC (888-436-3722) Para espanol, visita: http://www.generac.com/service-support/product-support-lookup Pour le frangais,visiter: htto://www.generac.com/service-sUpr)ort/product-support-lookup t � Use this page to record important information about your Generac Product Record the information found on your unit data label on Operation and Maintenance: Proper maintenance and this page. See Specifications. care of the energy storage system ensures a minimum When contacting an Independent Authorized Service number of problems and keeps operating expenses at a Dealer (IASD) or Generac Customer Service, always minimum. It is the operator's responsibility to perform all supply the complete model number and serial number of safety checks, to verify that all maintenance for safe the unit. operation is performed promptly, and to have the equipment checked periodically by an IASD. Normal maintenance, service, and replacement of parts are the responsibility of the owner / operator and, as such, are not considered defects in materials or workmanship within the terms of the warranty. Individual operating habits and usage may contribute to the need for additional maintenance or service. Table 1 -Important Information Description Model Number Serial Number Date Date Purchased Commissioned PWRcell Battery Battery Module 1 Battery Module 2 Battery Module 3 Battery Module 4 Battery Module 5 Battery Module 6 &WARNING CANCER AND REPRODUCTIVE HARM www.P65Warnings.ca.gov. (000393a) ii Installation Manual for Generac PWRcell Battery Table of Contents Section 1: Safety Rules & General Section 4: Installing PWRcell Battery Information Carton Contents Introduction ..........................................................1 Preparing Location ............................................15 Read This Manual Thoroughly ....................................1 Unboxing Battery Enclosure ............................15 SafetyRules .........................................................1 How to Obtain Service 1 Installing Battery Enclosure .............................15 Fastener Requirements .............................................15 General Hazards ..................................................2 Fastening Recommendations ......15 .............................. Electrical Hazards ................................................3 Installing Foot Bracket(OR model only) ....................16 Battery Hazards 4 Installing Wall Bracket ...............................................16 Fire Hazards .........................................................4 Battery Knockout Locations (IR and OR models) ...........................................17 General Rules .......................................................5 Placing Chassis onto Bracket and Leveling Feet.......18 Before You Begin .....................................:..................5 Standards Index ..........................................................5 Installing REbus wiring ............................. ...18 Safety Precautions 6 Note on DC Wiring and the NEC ......................19 Symbols .......................................................................6 Remote Shutdown Switch Connections (If equipped) .......................................................19 Section 2: General Information Connecting Blackstart Battery .........................21 PWRcell Battery Naming Convention 7 Module Dimensions ..........................................21 Specifications 8 Installing Battery Modules ................................22 BatteryModule Technical Data 9 Installing Rear Modules .............................................23 """"""""""""" Installing Grounding Tabs ......................................... Serial Number Location ....................................10 Installing Front Modules ............................................23 Unit Dimension 10 Installing Module Spacer(PWRcell M3 and PWRcell M5 Indoor Installation Dimensions .................................10 only) ..........................................................................23 Outdoor Installation Dimensions ..............................10 Installing Retention Clips ...........................................24 About PWRcell Battery ......................................11 Connecting COM Cables (DCB and EX Modules) .....................................25 Component Locations .......................................12 Connecting Battery Power Cables ...................26 Battery Disconnect Switch ...............................12 Installing Cover .................................................27 Battery Status LED ............................................12 To remove the cover 27 . ................................................ Upgrading PWRcell Battery ..............................28 Section 3: Location and Compliance Using Vset Function ..................................................28 Location and Clearances ..................................13 Maximizing Battery Capacity After Upgrade ..............28 PWRcell IR(Indoor Rated Model) .............................13 PWRcell OR(Outdoor Model) ...................................13 Compliance ........................................................14 Operating Temperature Range and Environmen- tal Requirements ................................................14 Installation Manual for Generac PWRcell Battery iii Section 5: Commissioning General Information .....................:.....................29 Commissioning Procedure ...............................29 Configure Battery ......................................................29 EnableBattery ..........................................................29 Confirm Island Mode is Enabled ...............................29 Operating Modes, Charging Parameters, and Setpoints ............................................................29 Battery Settings .................................................30 Decommissioning ..............................................31 Decommissioning Plan .............................................31 Battery Recycling ......................................................31 Section 6: Wiring Diagrams PWRcellM3 ..........................:.............................33 PWRcellM4 ........................................................34 PWRcellM5 ........................................................35 PWRcellM6 ........................................................36 Section 7: Troubleshooting General Troubleshooting ..................................37 iv Installation Manual for Generac PWRcell Battery Safety Rules&General Information Section 1: safety Rules & General Information Introduction not all inclusive. If using a procedure, work method, or This installation manual provides instructions and operating technique that the manufacturer does not spe- cifically recommend, verify that it is safe for others and recommendations for installing and commissioning the does not render the equipment unsafe. Generac PWRcell° Battery. The PWRcell Battery is Throughout this publication, and on tags and decals designed to house compatible lithium ion battery affixed to the unit, DANGER, WARNING, CAUTION, and modules, and connects directly to the PWRcell Inverter NOTE blocks are used to alert personnel to special and other REbusT"' compatible components of the instructions about a particular operation that may be haz- ardous if performed incorrectly or carelessly. Observe This installation manual includes full details on them carefully.Alert definitions are as follows: installation, wiring, safety, inverter integration, and other key aspects of installing the battery. The companion i document to this installation manual is the Generac PWRcell Battery Owner's Manual. See the Generac Indicates a hazardous situation which, if not avoided, PWRcell Battery Owner's Manual for complete will result in death or serious injury. information on user-configurable features. The information in this manual is accurate based on (000001) products produced at the time of publication. The manufacturer reserves the right to make technical AWARNING updates, corrections, and product revisions at any time without notice. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Read This Manual Thoroughly (000002) ®WARNING Consult Manual. Read and understand manual ®CAUTION completely before using product. Failure to Indicates a hazardous situation which, if not avoided, completely understand manual and product could result in death or serious in u could result in minor or moderate injury. � ry•(000100a) If any section of this manual is not understood, contact (000003) the nearest Independent Authorized Service Dealer (IABD) or Generac Customer Service at 1-888-436-3722 NOTE: Notes contain additional information important to (1-888-GENERAC), or visit www.generac.com for start- a procedure and will be found within the regular text of ing, operating, and servicing procedures. The owner is this manual. responsible for correct maintenance and safe use of the These safety alerts cannot eliminate the hazards that unit. they indicate. Common sense and strict compliance with This manual must be used in conjunction with all other the special instructions while performing the action or supporting product documentation supplied with the service are essential to preventing accidents. product. SAVE THESE INSTRUCTIONS for future reference.This manual contains important instructions that must be fol- lowed during placement, operation, and maintenance of How to Obtain Service the unit and its components. Always supply this manual For assistance, contact the nearest Independent Autho- to any individual that will use this unit, and instruct them rized Service Dealer (IASD) or Generac Customer Ser- on how to correctly start, operate, and stop the unit in vice at 1-888-436-3722 (1-888-GENERAC), or visit case of emergency. www.generac.com. When contacting Generac Customer Service about parts Safety Rules and service, always supply the complete model and The manufacturer cannot anticipate every possible cir- serial number of the unit as given on its data decal cumstance that might involve a hazard. The alerts in this located on the unit. Record the model and serial numbers manual, and on tags and decals affixed to the unit, are in the spaces provided on the front cover of this manual. Installation Manual for Generac PWRcell Battery 1 . R Safety Rules & General Information General Hazards • Connecting the PWRcell system to the electric util- ity grid must only be done after receiving prior Loss of life. Property damage. Installation must approval from the utility company. always comply with applicable codes, standards, laws Only competent, qualified personnel should install, and regulations. Failure to do so will result in death operate, and service this equipment. Strictly com- or serious injury. (000190) ply to local, state, and national electrical and build- ing codes.When using this equipment, comply with G regulations established by the National Electrical AWARNINCode (NEC), CSA Standard; the Occupational Electrocution.Potentially lethal voltages are generated Safety and Health Administration (OSHA), or the by this equipment.Render the equipment safe before local agency for workplace health and safety. attempting repairs or maintenance.Failure to do so could result in death or serious injury. Protection against lightning surges in accordance (000187) with local electric codes is the responsibility of the installer. AWARNING NOTE: Lightning damage is not covered by warranty. Equipment damage. Only qualified service personnel may • If working on energized equipment while standing install,operate,and maintain this equipment. Failure to on metal or concrete, place insulative mats over a follow proper installation requirements could result in death, dry wood platform. Work on this equipment only serious injury,and equipment or property damage. (000182a) while standing on such insulative mats. • Never work on this equipment while physically or ®WARNING mentally fatigued. Electric shock. Only a trained and licensed electrician • Any voltage measurements should be performed should perform wiring and connections to unit. Failure to with a meter that meets UL3111 safety standards, follow proper installation requirements could result in death, and meets or exceeds overvoltage class CAT III. serious injury,and equipment or property damage. (000155a) ®WARNING Risk of injury. Do not operate or service this machine if not fully alert. Fatigue can impair the ability to operate or service this equipment and could result in death or serious injury. (000215a) ®WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) ACAUTION Equipment damage.Connect only to REbus-compatible devices to the DC bus. Never connect to any other DC power source.Connecting to other DC power sources could result in equipment damage. (000598a) 2 Installation Manual for Generac PWRcell Battery Safety Rules&General Information Electrical Hazards Fill® J 1II'I AWARNING Electrocution. Never connect this unit to the electrical �l Electrocution. Refer to local codes and standards for system of any building unless a licensed electrician safety equipment required when working with a live has installed an approved transfer switch. Failure to electrical system. Failure to use required safety do so will result in death or serious injury. equipment could result in death or serious injury. (000150) (000257) ! - ACAUTION Electrocution. PWRcell Battery front cover should Equipment damage. Exceeding rated voltage and be removed by a qualified technician only. current will damage the auxiliary contacts. Verify Removing the front cover could result in death, that voltage and current are within specification serious injury,equipment or property damage. before energizing this equipment. (000604) (000134a) ! JACAUTIONI Electrocution. Do not wear jewelry while Equipment damage.Verify all conductors are tightened working on this equipment. Doing so will to the factory specified torque value. Failure to do so result in death or serious injury. could result in damage to the switch base. (000188) (000120) i Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000104) ! I , Electrocution. In the event of electrical accident, immediately shut power OFF. Use non-conductive implements to free victim from live conductor.Apply first aid and get medical help. Failure to do so will result in death or serious injury. (000145) P1 BY-1 Electrocution.Turn battery disconnect OFF and de-energize REbus before touching terminals. Failure to do so will result in death,serious injury, equipment and property damage. (000599) Electrocution.Turn utility supply OFF before working on utility connections of the transfer switch. Failure to do so will result in death or serious injury. (000123) ! 1 , Electrocution.Verify electrical system is properly grounded before applying power. Failure to do so will result in death or serious injury. (000152) Installation Manual for Generac PWRcell Battery 3 Safety Rules &General Information Battery Hazards Fire Hazards AWARNING t& JAWARNING1 Explosion.Do not dispose of batteries in a fire. Fire hazard.Never attempt to fight a fire yourself. Batteries are explosive.Electrolyte solution can cause Evacutate the building and contact emergency services. burns and blindness.If electrolyte contacts skin or eyes, Inform dispatcher that lithium-ion batteries are in the flush with water and seek immediate medical attention. building.Failure to do so could result in death,serious (000162) injury,or property or equipment damage. (000603) AWARNING JAWARNINGI Environmental Hazard.Always recycle batteries at anFire and explosion. Installation must comply with all official recycling center in accordance with all local local,state,and national electrical building codes. laws and regulations. Failure to do so could result in Noncompliance could result in unsafe operation, environmental damage, death,or serious injury. equipment damage,death,or serious injury. (000228) (000218) ACAUTION AVUARNING Equipment damage. Use ONLY manufacturer approved Risk of Fire. Unit must be positioned in a battery modules. Using any other module could damage manner that prevents combustible material Generac PWRcell Battery and may void the warranty. accumulation underneath. Failure to do so (000601) could result in death or serious injury. (000147) ACAUTION /' �� AWARNING Ensure all battery modules installed in any single Risk of fire. Do not crush,puncture,or subject PWRcell Battery are the same type (EX or DCB). battery units or modules to strong impacts. Failure Connecting different battery types can result in to do so could result in death,serious injury, equipment damage. (000731a) property damage,or equipment damage. (000730) Always recycle batteries in accordance with local laws and regulations. Contact your local solid waste collection site or recycling facility to obtain information on local recycling processes. For more information on battery recycling, visit the Battery Council International website at: http://batterycouncii.org. 4 Installation Manual for Generac PWRcell Battery Safety Rules&General Information General Rules Standards Index ! ® ' ®WARNING Loss of life. Property damage. Installation must alwaysLoss of life.This product is not intended to comply with applicable codes, standards, laws and be used in a critical life support application. regulations. Failure to do so will result in death 0 Failure to adhere to this warning could result or serious injury. (000190) in death or serious injury. (000209b) ®WARNING Strictly comply with all applicable national, state, and local laws, as well as codes or regulations pertaining to Loss of life.Only qualified personnel may install this battery. the installation of the system. Use the most current Installation of a PWRcell Battery by a homeowner is version of applicable codes or standards relevant to local prohibited.Installation by unqualified personnel may result in jurisdiction, equipment used, and installation site. death,serious injury,equipment or property damage. (000638a) NOTE: Not all codes apply to all products and this list is not all-inclusive. In the absence of pertinent local laws AWARNING and standards,the following publications may be used as Environmental Hazard.Always recycle batteries at an a guide (these apply to localities which recognize NFPA official recycling center in accordance with all local and ICC). laws and regulations. Failure to do so could result in 1. National Fire Protection Association (NFPA)70: environmental damage,death, or serious injury. (000228) The NATIONAL ELECTRIC CODE(NEC) 2. NFPA 855: Standard for the Installation of • Follow all safety precautions in the owner's manual, Stationary Energy Storage Systems installation guidelines manual, and other documents 3. NFPA 10: Standard for Portable Fire Extinguishers included with the equipment. 4. NFPA 70E: Standard For Electrical Safety In The • Never energize a new system without opening all dis- Workplace* connects and breakers. 5. NFPA 220: Standard on Types of Building • Always consult local code for additional requirements Construction * for where unit is being installed. 6. NFPA 5000: Building Code • Incorrect installation can result in personal injury and 7. International Building Code** damage to the unit. It may also result in the warranty g, International Fire Code being suspended or voided. All instructions listed 9. International Residential Code below must be followed including location clearances and conduit sizes. 10. Agricultural Wiring Handbook*** 11. Article X, NATIONAL BUILDING CODE Before You Begin 12. ASAE EP-364.2 Installation and Maintenance of • Contact your local utility provider for approval before Farm Standby Electric Power**** installation. Install the battery in accordance with all 13. NFPA 1 Fire Code utility installation requirements. This list is not all-inclusive. Check with the Authority • Contact local inspector or city hall to be aware of all Having Local Jurisdiction (AHJ) for any local codes or federal, state, and local codes which could impact standards which may be applicable to your jurisdiction. installation. Secure all required permits before The above listed standards are available from the installing. following Internet sources: • Fully comply with all relevant NEC, NFPA, and OSHA * www.nfpa.org standards, as well as all federal, state, and local ** building and electric codes. This unit must be www.iccsafe.org installed in accordance with current NFPA and ICC ***www.rerc.org Rural Electricity Resource Council P.O. standards, and any other federal, state, and local Box 309 Wilmington, OH 45177-0309 codes for minimum distances from other structures. **** www.asabe.orgAmerican Society of Agricultural & Biological Engineers 2950 Niles Road,St.Joseph, MI 49085 Installation Manual for Generac PWRcell Battery 5 Safety Rules &General Information Safety Precautions Symbols Warning symbols are used to warn of the conditions that may cause severe injury or damage to equipment.The follow- ing table describes the warning symbols used in the equipment's markings and within this document. This equipment contains high voltage which can cause electric shock resulting in severe injury. Ensure polarity of connections during assembly. Keep equipment away from open flame or ignition sources. 119 ' Read the manual before installing and operating the equipment. The equipment is heavy enough to cause severe injury. Ain- _ The battery pack may leak corrosive electrolyte if damaged. '' The battery pack may explode if damaged. fir_'__ The equipment should not be disposed of in household waste. Physical injury or damage to equipment may occur if related requirements are not followed. Do not disassemble the equipment. 6 Installation Manual for Generac PWRcell Battery General Information Section 2: General Information PWRcell Battery Naming Convention PWRcell IR M3 DCB PRODUCT SERIES BATTERY SERIES PWRcell Series DCB EX ENCLOSURE TYPE NUMBER OF BATTERY MODULES IR- Indoor Rated 3 -Three Modules OR - Outdoor Rated 4 - Four Modules 5 - Five Modules 6 - Six Modules 012273 Installation Manual for Generac PWRcell Battery 7 General Information Specifications ®CAUTION Ensure all battery modules installed in any single PWRcell Battery are the same type (EX or DCB). Connecting different battery types can result in equipment damage. (000731 a) Description Units PWRcell M3 PWRcell M4 PWRcell M5 PWRcell M6 Energy Usable Energy kWh 9 12 15 18 Power Nominal Cont. Power* kW 3.4 4.5 5.6 6.7 Max.Cont.AC Power** kW 4.5 6 7.5 9 Nominal Cont. DC Current(Charge/Discharge) A 11.6 15.5 19.4 23.3 Peak Motor Starting Current(2 sec) A,RMS 25 33 42 50 Battery Modules Number — 3 4 5 6 For DCB modules-DC Voltage(per module) VDC 46.8(39—52) For EX modules-DC Voltage(per module) VDC 43.2(36—49.8) Max Energy Output(per module) kWh 3.0 For DCB modules-Module Weight Ib(kg) 55(25) For EX modules-Module Weight Ib(kg) 58(26.3) REbus Communication Protocol — REbus DC nanogrid Voltage: Input/output*** VDC 360-420 Round-Trip Efficiency(DC to DC) % 96.5 Temperature Maximum Ambient Operating Temperature T(°C) 14 to 122(-10 to 50) Optimal Ambient Operating Temperature °F(°C) 41 to 104(5 to 40) Installation Altitude Maximum Installation Altitude**** ft(m) 6,560(2,000) Weight(without mounting brackets) IR Enclosure Ib(kg) 110(50) OR Enclosure Ib(kg) 115(52) IR Installed-PWRcell IR w/DCB modules Ib(kg) 276(125) 331 (150) 386(175) 441 (200) IR installed-PWRcell IR w/EX modules Ib(kg) 282(128) 340 (154) 397(180) 454(206) OR Installed-PWRcell OR w/DCB modules Ib(kg) 280(127) 335(152) 390(177) 445(202) OR Installed-PWRcell OR w/EX modules Ib(kg) 287 (130) 344 (156) 401 (182) 459 (208) Compliance Safety — UL 9540, UL 1973, UL 1642, CSA 22.2#107.1 Seismic — I EEE693-High *Average AC power over a complete discharge cycle. **Peak performance, values provided for 104T(40°C) ***380VDC Nominal ****Module warranty void if installed above limit. Note:Charge/Discharge rate may be reduced at temperature extremes. Specifications are subject to change without notice. Refer to the product specification sheet for complete list. 8 Installation Manual for Generac PWRcell Battery General Information Battery Module Technical Data Physical Characteristics DCB Battery EX Battery Width 17.32±0.08in (440±2 mm) Length 17.72±0.08in (450±2 mm) Height 3.30±0.08in (84±2 mm) 3.46±0.08in (88±2 mm) Weight 55.12±0.1 lbs(25±0.5 kg) 58.42±0.1 lbs (26.5±0.5 kg) Electrical Characteristics DCB Battery EX Battery Cell type LiNiMnCo Usable Energy Capacity(Nominal) 3.0 kWh Usable Battery Capacity(Nominal) 64.1 Ah 69.4 Ah Nominal Voltage 46.8 VDC 43.2 VDC Voltage Range 39--53AVDC 33 —50.4 VDC Charge/Discharge Current(Nominal)* 12 A 27A Pulsed Charge/Discharge current(10 sec)* 24 A 40A DC Disconnect Fuse Scalability(number of modules in series) 3 to 6 Shelf life or maximum self-discharge rate 6 months maximum storage time BMS DCB Battery EX Battery System Voltage Monitoring parameters System Current Cell Voltage Cell temperature Communication RS-485 Operating Conditions DCB Battery EX Battery Maximum Ambient Operating Temperature 14 to 122°F(-10 to 50°C) Optimal Ambient Operating Temperature 41 to 104°F (5 to 40°C) Storage Temperature -4 to 104°F(-20 to 40°C) -4 to 140°F(-20 to 60°C) Altitude Max. 6,560 ft(2,000 m) Cooling Strategy Natural Convection Reliability&Certification DCB Battery EX Battery Cell: UL 1642 Certificates Battery Module: UL 1973 Transportation UN38.3 Ingress Rating IP20 Emissions FCC Part 15 Class B Battery Directive 2013/56/ RoHS Directive 2011 /65/ Environmental EU Reach EU, Rechargeable Battery Recycling Act *Values are listed for individual modules, refer to previous page for system-level performance values. Installation Manual for Generac PWRcell Battery 9 General Information Serial Number Location Unit Dimension JACAUTIONI Indoor Installation Dimensions Ensure all battery modules installed in any single PWRcell Battery are the same type (EX or DCB). Connecting different battery types can result in equipment damage. (000731a) Refer to Figure 2-1 to locate serial numbers for the unit (A) and the individual battery modules (B). Record this information in Table 1: Important Information on the inside front cover of this manual so it is available if the A tags are lost or damaged. When ordering parts or requesting assistance, you may be asked to provide this information. DCB Battery O B C 009892 Q, 3 4 — _ B Figure 2-2. Unit Dimensions o A 68-3/8 in(1,737 mm) r — — — — — - B 22 in (558 mm) I EX Battery I C 9-7/8 in(251 mm) I B I I == I Outdoor Installation Dimensions I a I I � I I I Do Not Mix Battery Types in a Single EnclosureI ° L _ _ _ _ - J O 012306 A Figure 2-1. Serial/Number Location B C 011162 Figure 2-3. Unit Dimensions A 73 3/16 in(1,859 mm) B 26 1/8 in(663 mm) C 11 in(279 mm) 10 Installation Manual for Generac PWRcell Battery General Information About PWRcell Battery The PWRcell Battery is the storage component of the is directly connected to PV Links (B) and PWRcell PWRcell system. The battery can be used for. grid- Battery (C) on the DC (REbus) lines (D).,To the right of connected solar applications such as Self Supply, Rate the inverter are AC lines:240VAC or 208VAC for grid and Arbitrage, and Clean Backup Power. The battery is home loads, and essential load support. Load support designed to work seamlessly with Generac PV Links and varies by model and number of battery modules the PWRcell Inverter to form the PWRcell system for attached. Refer to Specifications for more information. grid-tied solar-plus-storage. All PWRcell products use the REbus 380VDC nanogrid to connect to each other.The REbus nanogrid automates the flow of power to enable plug-and-play setup -and operation of PWRcell equipment. In Figure 2-4, a REbus-compatible PWRcell Inverter(E) F C E A O D D H BB B ❑� 009893 Figure 2-4. Generac PWRcell System Example. A Solar Panels E PWRcell Inverter B PV Link.Optimizers F Grid C PWRcell Battery G Loads D REbus H Protected Loads Installation Manual for Generac PWRcell Battery 11 General Information Component Locations Battery Disconnect Switch A Electrocution.Initiate a system-wide shutdown and turn the PWRcell DC Disconnect Switch OFF on all connected E batteries before performing"service.Failure to do so will p result in death,serious injury,or equipment and property B damage. (000600) See Figure 2-5. Battery. Disconnect Switch (A) disconnects the battery stack from the battery monitoring system(BMS)electronics. o The Battery Disconnect Switch must be locked in the OFF position during installation. The switch bracket accepts a standard lockout/tagout lock. NOTE: Tum Battery Disconnect Switch OFF and turn the REbus DC disconnect for the battery OFF at the inverter whenever the battery will be powered down and left inactive for an extended period of time. Battery Status LED See Figure 2-5. The color and strobing interval of LED (B)communicates battery status. Table 2-1. Battery Status LED LED Color/Interval Battery Status 009890 Orange, solid Disabled Figure 2-5. Component Locations Orange, strobe (2s) Waiting A Battery Disconnect Switch Green/Orange, alternating Initializing B Battery Status LED Green,solid Charging C Intake Filter Green, rapid blinking (0.5s) Discharging D Front Cover Green, strobe(2s) Standby E Exhaust Vent Red, rapid blinking (0.5s) Error NOTE: PWRcell IR model shown. Red,strobe(8s) Sleeping 12 Installation Manual for Generac PWRcell Battery Location and Compliance Section 3: -Location and Compliance Location and Clearances Do not expose the battery to extreme tempera- tures. See Specifications for recommended and PWRcell IR (Indoor Rated Model) acceptable operating temperatures. Operating the Install the PWRcell Battery in dwelling units in the follow- battery outside of the recommended range may ing permitted locations only: degrade performance. • Attached garages separated from dwelling .unit NOTE: Consider year-round temperature extremes habitable spaces in accordance with local building when choosing a location.'In extreme climates, always Code. . install the battery in a conditioned space. Generac rec- • Detached garages and accessory structures. ommends installing the battery in a conditioned space • Utility closets and storage or utility spaces. regardless of climate. • Basements. Table 3-1.'Minimum Airspace Clearances • Other locations not categorized as habitable space Sides 2 in Minimum 2 in(5.08 cm)on each side in a dwelling unit. (5.08 cm) to operate cover.. NOTE: Refer to the local Building Code for permitted 3 in Minimum 3 in(7.62 cm)on top so locations for commercial installations. Top (7.62 cm) installer can lift body onto mounting bracket. When selecting a location, consider the following: 36 in Minimum 36 in (91.4 cm)in front for • Install in indoor locations only. Front (91.4 cm) maintenance/service in accordance If the room or space where the battery is to be with NEC Article 110.26. installed is not finished,the wall and ceilings of the room or space shall be protected in accordance PWRcell OR (Outdoor Model) with local building or fire codes. The Generac PWRcell OR (outdoor) model battery may • Install only in clean, dry locations. be located in the same locations as the IR (indoor) • Do not allow bottom or front vents to become_ model, and,, also in suitable exterior locations, in blocked. accordance with these instructions and applicable local • See Table 3-1. Ensure minimum clearances are and national codes. met. When selecting a location, consider the following: • Multiple battery units must be separated by mini- Install in well-managed, protected locations only. mum 3 ft (91.44 cm) between the units per.NFPA De-rr6Hnstal1�r-her==e-damage-from•vehisles, recre-. 855. ational vehicles or equipment, livestock, pedestri- NOTE: The PWRcell Battery uses the surrounding ambi- ans, or other activity may-uccur. ent air for cooling purposes. Inadequate airflow. can • This equipment is not suitable for installations out- cause the PWRcell Battery toderate its power import and doors in a marine environment. export for thermal management. If power derating is Do not install where irrigation systems or other insufficient, due to an abnormally high ambient operating equipment will spray water onto unit. temperature, the battery will disconnect and enter a pro- Install only to flat, plumb (vertical) walls on sturdy, tective error state, requiring manual intervention to recon- structurally-sound buildings. Do not install on nett once temperatures cool. The PWRcell Battery does mobile homes or small, lightweight, temporary, or not require the installation and use of an external ventila- portable buildings that could blow over in the wind. tion system. • Do not attempt to support the unit on soft, deform- • The battery installation location must meet the able surfaces or surfaces prone to move due to working space requirements in NEC Article 110.26. frost activity or subsidence. Use the included foot • If installed in a garage or other location where the bracket assembly instead. battery could be damaged by a vehicle,the battery • Do not install where leaves, snow,•dirt, sand, or must be protected by approved barriers that are other debris may block the air intake at the base of installed in accordance with local building code. the unit. NOTE: The installation and use of smoke or heat detec- • Do not install where grass, vines, ivy, landscape tors within areas of the dwelling unit or attached garage plantings, or other vegetation may obscure access, where the PWRcell Battery is installed is suggested block vents, or intrude into the unit. where not required by the locally adopted building code. Installation Manual for Generac PWRcell Battery 13 Location and Compliance • Do not install where excessive amounts of water ' Compliance from roof runoff, landscape irrigation, water sprin- klers, or sump pump discharge could contact the enclosure. Loss of life. Property damage. Installation must • Do not install where water levels may rise and con- always comply with applicable codes, standards, laws tact the unit. and regulations. Failure to do so will result in death • Do not install within 3 ft(92 cm)to any door or win- or serious injury. (000190) dow. • The battery installation location must meet the out- door working space requirements in NEC Article AWARNING 110.26 Electrocution.Refer to local codes and standards for safety equipment required when working with a live • The PWRcell Battery is not intended for use in electrical system.Failure to use required safety mobile(e.g. RV)or portable applications. equipment could result in death or serious injury. • Do not expose the PWRcell Battery•to extreme (000257) temperatures. See Specifications for rec- ommended and acceptable operating tempera- AWA. tures. Operating the Generac PWRcell Battery Equipment damage. Only qualified service personnel may outside of the recommended range may degrade install,operate,and maintain this equipment. Failure to performance. follow proper installation requirements could result in death, • Mlultip6.ba^ttery-w pits-m ustx�bexseparatedmbymmmin-P serious injury,and equipment or property damage. ' (000182a) M m a4,t"l9 4A cm)�t5etween-&th-e-unfits a—, FP}P Egg Follow all instructions included in this manual and use appropriate practices for all product wiring and installa- NOTE: Consider year-round temperature extremes when tion. choosing a location. In extreme climates, always install PWRcell Battery in a conditioned space. Generac NOTE: It is the responsibility of the installer to ensure recommends installing PWRcell Battery in a conditioned electrical worker safety, including conformance with lock- space regardless of climate. out/tagout procedures for servicing PWRcell equipment. • See Table 3-2. Ensure minimum clearances are Operating Temperature Range and met' Environmental Requirements Table 3-2. Minimum Airspace Clearances q Sides 2 in Minimum 2 in (5.08 cm)on each side The PWRcell Battery can operate within the maximum (5.08 cm) to operate cover. ambient operating temperature range. For best perfor- Minimum 3 in (7.62 cm) on top so mance, install the PWRcell Battery in an environment Top 3 in installer can lift body onto mounting where ambient temperatures fall within the optimal oper- (7.62 cm) bracket. ating temperature range.The PWRcell Battery will limit or Minimum 36 in (91.4 cm) in front for halt charge/discharge power at extreme temperatures. Front 36 in maintenance / service in accordance For hotter climates, install the battery out of direct sun- (91.4 cm) with NEC Article 110.26. light. Exposure to temperatures above the optimal tem- Bottom 3 in Minimum 3 in(76.2 mm)from grade perature range will impact battery performance. (76.2 mm) For colder climates, install the battery in a conditioned space. .Exposure to temperatures below the optimal ambient temperature range will impact.battery perfor- mance. 14 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery Section 4: Installing PWRcell Battery Carton Contents Installing Battery Enclosure • Wall bracket ®WARNING • Lower wall mount and foot brackets (Outdoor Personal injury.Use caution when handling heavy parts and Rated model only). battery modules.Lift heavy parts in teams if necessary. Failure • Chassis, including pre-installed electronics to do so could result in death,serious injury,and equipment or package, battery jumpers, and cover. property damage. (000697) • Hardware kit. • Generac PWRcell Battery Installation Manual and ®WARNING Generac PWRcell Battery Owner's Manual. Personal injury. Install PWRcell Battery enclosure before installing battery modules within the enclosure. Failure to NOTE: Lithium ion battery modules are shipped sepa- do so could result in death,serious injury,or equipment or rately. Keep battery modules in their original packaging property damage. until installation. Observe storing and stacking require- ments. PWRcell Battery must be installed using wall bracket pro- vided. PWRcell Battery must also have its pre-installed Preparing Location adjustable feet supported from below. For outdoor rated • Verify grade is smooth. A sharply sloping or models, use the designated foot brackets. irregular floor may hinder front cover installation. To scale Installation Template for critical mounting loca- • Sweep away any debris or dust that could get tions and requirements located on inside of packaging. pulled into the PWRcell Battery bottom intake vent. See Figure 4-6 on the following page for battery dimen- Unboxing Battery Enclosure sions and knockout locations. See Specifications for 1. Lay package on one of the long edges. unit weight. 2. Remove top cardboard cap. Fastener Requirements 3. Remove Documentation and Hardware box and NOTE: The details below are minimum guidance. Con- set aside in a safe place. sult local building codes and a structural engineer to 4. Remove cardboard sleeve. ensure the use of appropriate fasteners. 5. Lay unit onto its back. • Minimum 4 structural fasteners required for wall 6. Remove bottom cardboard cap. bracket, corrosion protected steel, diameter 1/4 in. 7. Remove the battery front cover by sliding cover • Minimum 4 structural fasteners required for foot toward the top of the unit, swinging cover bottom bracket. out, and pulling the cover down. • Fastener head clearance 5/8 in tall, 7/8 in diameter. 8. Set cover aside in a safe place. • Use a flat washer between the fastener head and NOTE: Do not adjust the feet at this time. The feet are wall bracket if fastener is not a flanged head. shipped pre-positioned to ensure sufficient clearance for front cover. Fastening Recommendations • All fasteners must engage 1.5 in (3.8 cm) with a structural member. If mounting into stud framing use a stud finder to locate the center of the stud. • If mounting into stud framing, the bracket must be fastened to a minimum of two separate structural members. • If mounting to a foundation or masonry, make sure fasteners are clear of any mortar joints. • If stud is greater than 16 in on center, a cross brace must be used. • If mounting on vinyl siding, unistruts must be used. • Brackets must be level. • Verify distance between shelf bracket and bottom. Installation Manual for Generac PWRcell Battery 15 Installing PWRcell Battery Installing Foot Bracket (OR model only) Installing Wall Bracket Mount foot bracket to wall with the following procedure: • See Figure 4-4. Bottom edge (A) is 29-5/8 in (752 A template is included and will help locate the holes for mm)off the floor for IR installations. both Wall and Foot Brackets. • Each horizontal brace requires a minimum of two • Before finalizing horizontal location for upper and fasteners. Four total fasteners are required. All lower wall mount, ensure all bolts will line up with fasteners must engage structural materials by a wall studs. minimum of 1.5 in. All fasteners must be field • Lower mount should maintain of distance of 3 in supplied. Installer must ensure that fasteners minimum from grade. selected are appropriately rated for this application. • See Figure 4-1. Install the lower wall mount with flat washers and lag bolts (A). NOTE: Do not install the top bolts at this stage. This will inhibit foot bracket installation. ® A I 009920 A V Figure 4-4. Wall Bracket 011153 Figure 4-1. Install Lower Wall Mount For OR installations, mount wall bracket to wall with the following procedure: • See Figure 4-2. Slide foot bracket (A) into bottom . See Figure 4-5. Once the lower wall mount is bracket (B) making sure underside of pockets clear installed make sure the mounting holes to the lower bottom bracket before engagement. Proper wall mount(B)line up with the upper wall mount(A) installation is achieved by lining up the top edge of for 16 in on center studs (C). Four screws are lower wall mount to the bottom edge of wall flange part of foot bracket. required in lower wall mount. • Be sure to maintain 34 7/8 in (886 mm) spacing O between bottom holes in upper wall mount and bottom holes in lower wall mount. A A 17 3 16 in 436 mm o 011155 I Figure 4-2. Insert Foot Bracket into Lower Mount I • See Figure 4-3. Use flat washers and lag bolts (A) B j 16 in j to secure top of lower mount. 4 3/16 in j (406.4 mm) j 34 7/8 in (106.8 mm) (886 mm) I O I /�� I I 011154 Figure 4-5.Lower and Top Bracket Alignment At 011156 Figure 4-3. Install Top Bolts in Lower Wall Mount 16 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery Battery Knockout Locations (IR and OR models) 1-5/16 in �1 (3.3 cm) i 13-3/8 in i (34 cm) i 57-5/8 in 9-3/8 in (146.3 cm) i ------- (23.9 cm) 1-114 in (3.12 cm) i 42-13/16 in 41-5/8 in (108.7 cm) � (105.7 cm) ----- - ®- 29-5/8 in (75.184 011210 Figure 4-6. Battery Knockout Locations(IR and OR models) Installation Manual for Generac PWRcell Battery 17 Installing PWRcell Battery Placing Chassis onto Bracket and Leveling Feet 6. Verify there is minimum 1-3/4 in (4.45 cm) gap 1. See Figure 4-7. Lift body (A) onto bracket (B). between the bottom of the body and the floor. Keep body tight to the wall while lowering body 7. Tighten machine screws to bracket and torque to onto bracket.Verify bracket tabs(C)hook into body 13 in-Ib(1.47 Nm). pockets (D). 8. Verify feet have not lifted from floor. 9. Tighten feet jam nuts to lock them in place. ° D c Installing REbus wiring q �J Electrocution.Put the Generac PWRcell Inverter into Safety Shutdown before installing wiring.If there are any B other batteries connected to REbus,toggle their front Battery Disconnect switches to OFF.Failure to do so will result in death or serious injury. (000606) ®CAUTION Equipment damage. Never connect REbus conductors to ground. Connecting REbus conductors to ground 009926 could result in equipment or property damage. Figure 4-7. Mounting Bracket(1 of 2) (000607a) 2. See Figure 4-8. Align body slots (E) with wall bracket holes (F). ACAUTION Equipment damage.Connect only to REbus-compatible devices to the DC bus. Never connect to any other DC E power source.Connecting to other DC power sources could result in equipment damage. (000598a) • i When installing REbus wiring: o • Wiring must be installed in accordance with Article 706 in the NEC. • Wiring must comply with local electrical codes. F - Wiring must be grounded according to local codes. When required, grounding is the responsibility of ' the installer. For proper REbus communication, ensure the chassis is securely bonded to the PWRcell Inverter via the grounding bar in the PWRcell Inverter wiring compartment. 009927 ' Wiring must be protected from exposed metal edges by using appropriate bushings, fittings, and Figure 4-8. Mounting Bracket(2 of 2) restraints. 3. Fasten body to bracket with two included M4x8mm ' Watertight conduit fittings are required for OR SEMS screws in each horizontal bracket brace. model. NOTE: Start screws. Do not tighten. • Wiring must adhere to the following specifications: 4. Adjust feet as necessary to ensure the feet are car- Table 4-1.Wiring Specifications tying the weight of the unit. Specification Min Max Units 5. Check unit for plumb side to side. Adjust feet as Allowable wire size 10 6 AWG necessary ensure both stay in full contact with the Torque 13.3(1.5) 15.9(1.8) Ib-in(N-m) floor. Strip length 3/8(10) in (mm) IMPORTANT NOTE: Do not lift the body off the Temperature rating 90 C bracket by over lengthening the feet. 18 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery To install REbus wiring: Remote Shutdown Switch COnneC- 1. See Figure 4-9. Install REbus conductors to their tions (if equipped) terminal blocks: RE+to red (A), RE-to blue(B). NOTE: See Figure 4-10. The STOP terminals ship with 2. Install equipment grounding conductor to green ter- a 14 AWG jumper '(A)_ installed. Remove this jumper minal block(C). before installing an external shutdown switch. 3. If required, route field,wiring conductors through e the grommet wiring chase baffle(D). - NOTE: Do not route wires around the baffle. 4. At the PWRcell Inverter, install RE+ and RE- con- ductors to'any unused 30A REbus DC disconnect. 5. Secure equipment grounding conductor to -the PWRcell Inverter ground bar. A + STOP - �� _0 CK Qo _ ttE«RETURN BATTERY DISCONNECT"OFF" O B AND DE-ENERGIZE REBUS BEFORE A TOUCHING TERMINALS C REMOVE FOR flEMOiE SXUiOO SLMCH Y \ ® 012362 Q D Figure 4-10. Remove Jumper See Figure 4-11. Connect the wiring to the external shut- 009926 down switch (field supplied) to battery STOP terminals. The STOP Terminals accept 20 to 12 AWG, solid or Figure 4-9. REbus Wiring stranded wire.As shown, 14 AWG THWN (600V) wiring. can be used and run in the same conduit as the REbus Note on DC Wiring and the NEC wires. Some electricians or installers may be unfamiliar with DC e wiring in a residential setting. Note the following: • NEC 215.12(C)(2)for correct DC wiring coloring. • 'NEC 210.5(C)(2) for identification of DC conduc- tors carrying more than 50V. Always adhere to applicable codes when marking and installing DC conductors. See Table 4-2. For all REbus DC wiring observe the fol- lowing coloring convention: + STOP - Table 4-2. REbus DC Wiring Coloring Convention TURN BATTERY "OFF" Wit Wlre . Color AND DE-ENERGIZE REBUS BEFORE REbus+(RE+) Red TOUCHING TERMINALS . REbus-(RE-) Black or Blue with Black Sleeving Ground(GND) Green NOTE: Mark or flag all conductors as appropriate. 0 012363 Figure 4-11. Connect To Remote Shutdown Switch Installation Manual for Generac PWRcell Battery 19 Installing PWRcell Battery NOTE: Select a code compliant switch rated for STOP 3. See Figure 4-13. The STOP terminals and circuit voltage of 12VDC minimum and current greater remote shutdown switch can be wired in par- than or equal to 1A. Switch must be listed and meet the allel. In this case polarity matters. Wire the requirements of Article 404 of NFPA 70.A suitable choice "STOP+"of first device to"STOP+ of second is .Leviton 12021-21 Single-Pole Toggle Switch, 3A, 24V device. Wire the "STOP-" of first device to AC/DC. "STOP=' of second device. .From either • When the switch is in the OPEN or OFF position device, run a wire pair from the STOP termi- the remote shutdown will be activated. Switching to nals to the remote shutdown switch. the CLOSED or ON. position deactivates the Battery Inverter remote shutdown. +.STOP -. STOP — Remote • Installation of an external STOP switch does not Shutdown disable the Battery Disconnect Switch mounted on $wiich the top of the battery front panel. Opening the 012365 Battery Disconnect Switch will cause the battery Figure 4-13.Remote Shutdown Switch Parallel management unit(BMU)to open its contactors and Wiring isolate the battery stack from REbus,where REbus IMPORTANT NOTE: If polarity is wired incorrectly, will still have voltage if the inverter is enabled. neither device will see a STOP condition and it will Opening the battery's STOP circuit with an external not be possible to shutdown either device via the switch, however, will open the battery's contactors STOP terminals until the wiring,is corrected. .and initiate a system shutdown. Once a shutdown has been initiated, the inverter control panel must NOTE: Test the remote shutdown switch operation after be used to exit the shutdown and return the system installation. Enable all PWRcell devices connected to the to normal functionality. The system cannot exit remote shutdown switch. Initiate a remote shutdown by shutdown mode until the remote shutdown switch opening the remote shutdown switch. Verify the system has been returned to the closed position. has shutdown. After verification, disengage the remote • For PWRcell systems with multiple remote shutdown by closing remote shutdown switch. shutdown STOP circuits (multiple PWRcell NOTE: Local codes may require special labeling, indica- devices)several configurations can be used. tors;or other features. Requirements can vary by region, `1.An isolated multi-pole, single-throw NC switch so consult a local code enforcement officer for guidance. or button. Have the number of poles corre- spond with the number of STOP device inputs to be connected. Run a separate wire pair from each pole of the switch to the STOP inputs of each device. Polarity does not matter in this case. 2. See Figure 4-12. The STOP terminals and remote shutdown switch can be wired in one series circuit. In this case polarity matters. Wire the "STOP.+" of first device to "STOP-" of second device. Then wire the two remain- ing "STOP"terminals to the remote shutdown switch. Battery Inverter STOP,.( {D STOP — Remote Shutdown Switch 012364 Figure 4-12.Remote Shutdown Switch Series Wiring 20 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery Connecting Blackstart Battery See Figure 4-14. Connect blackstart battery lead to posi- ,,,,,,,,,, ®® ®oa OB tive battery terminal (E). NOTE: The negative lead is already connected to termi- nal (F). NOTE: Do not leave blackstart battery connected if PWRcell Battery is not connected to REbus. Blackstarf battery will enter a sleep mode and discharge to support p� the unit. E F ' ON , O OFF 0 • BATTERY DISCONNECT O O C OO O nnnnn..... unnnnni.un O� O� nnnninii,nitnnunniuiiiiii 011158 O O Figure 4-16.EX Module Outline Dimensions O O O n on A 17.72±0.08 in (450 mm±2) 009928 Figure 4-14.Blackstart Battery Connections B 3.46±0.08 in (88 mm±2) C 17.32±0.08 in (440 mm±2) ,Module Dimensions ��aa® O 0 0 as A 0 0 0 0 C 011292 Figure 4-15. DCB Modulee,Outline Dimensions " A 17.72±0.08 in (450 mm±2) B 3.31 ±0.08 in (84 mm±2) C 17.32±0.08 in (440 mm±2) Installation Manual for Generac PWRcell Battery 21 Installing PWRcell Battery Installing Battery Modules ®CAUTION Ensure all battery modules installed in any single PWRcell Battery are the same type(EX or DCB). Connecting different battery types can result in equipment damage. (000731 a) • Record battery module serial numbers prior to installation in Table 1: Important Information located in the inside front cover of this manual. • When installing battery modules, install top rear module first, regardless of configuration. • See Figure 4-17 for the order of battery module and spacer installation for PWRcell M3 (B), PWRcell M4 (C), PWRcell M5 (D), and PWRcell M6 (E). NOTE: Module spacers(F)are required on PWRcell M3 (B) and M5 (D)configurations. O O O O O O O O 1 0 O O 2 1 0 O O 2 1 0 O O 2 1 0 O O 2 O O O O O O O O O 4 O 0 0 4 O 0 0 4 O 0 0 4 30 Lh 3 0 0 3 0 3 0 O 6 O O O 6 0 F 5 5 O O O O O F OO 012440 Figure 4-17. Battery Module/Spacer Order of Installation 22 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery Installing Rear Modules 4. Fasten each grounding tab with a MU8 mm SEMS 1. See Figure 4-18. Angle top of battery module (G) screw(M)and torque to 13 in-Ib (1.47 Nm). under and behind bracket lip (H). zi IMPORTANT NOTE: Battery module ports (1) must face the right side of the PWRcell Battery body with the COM ports above the power port. 2. Slide bottom of module to back of PWRcell Battery ® M chassis(J). L 3. Push bottom of module against grounding clips(K). NOTE: Grounding clips are designed to contact and bite into the battery module case to provide an equipment grounding connection. 009931 Figure 4-20. Installing Top Grounding Tabs Installing Front Modules H See Figure 4-21. Install front battery modules (N) using O the same procedure as used on the rear modules. See 1p Figure 4-17. Battery Module/Spacer Order of Instal- lation. G J K • .• o • °i •� 00992960, • Figure 4-18.Installing Rear Battery Modules 1 • 0 Installing Grounding Tabs N � 1. See Figure 4-19. Install two L-shaped grounding tabs (L)at the bottom of the module on both sides. ° 009932 2. Fasten each grounding tab with a M4x8 mm SEMS screw(M)torque to 13 in-Ib (1.47 Nm). Figure 4-21. Installing Front Battery Modules Installing Module Spacer(PWRcell M3 and PWRcell M5 only) See Figure 4-22. Module spacers (0) must be installed on any single module shelf. M o i ® 009930 Figure 4-19.Installing Bottom Grounding Tabs 3. See Figure 4-20. Install grounding tabs (L) at the top of the module on both sides. Installation Manual for Generac PWRcell Battery 23 Installing PWRcell Battery O ` 2 O � D O O B009935 Figure 4-24. Installing Module Spacer(2 of 3) A � 4. See Figure 4-25. Secure spacer with two M4X8 SEMS screws and torque to 13 in-Ib (1.47 Nm). 0 009933 Figure 4-22. Module Spacer go PWRcell Battery modules and upgrade kits can be obtained by contacting Generac Customer Service at 1- O 888-436-3722 (1-888-GENERAC), or www.gen- erac.com. NOTE: Kits must be installed by a qualified individual. Table 5—Module Spacer Kit Module Spacer Kit Part Number B B Generac PWRcell Spacer Kit APKE00008 v To install module spacer: 1. See Figure 4-23. Angle top of spacer (P) under 009936 and behind bracket lip(Q). Figure 4-25. Installing Module Spacer(3 of 3) .. , Installing Retention Clips /.� Q See Figure 4-26. All front battery modules must be secured with retention clips (R). o P e 009934 Figure 4-23. Installing Module Spacer(1 of 3) 2. See Figure 4-24. Slide spacer up between brackets. C 3. Push bottom of spacer in. I I I 009937 Figure 4-26.Retention Clips(1 of 3) 24 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery See Figure 4-27. Note that there are three types of 3. . Secure'retention clip to bracket with a M4X8 mm retainer clips: double retention clips (U), single retention screw and torque to 13 in-Ib (1.47 Nm). clips marked O (T).and single retention clips marked X (S). Connecting COM Cables (DCB and EX • Install single retention clips (T) (S) at the top and Modules) bottom of the stack. See Figure 4-29 for a description of the module connec- • Install double retention clips (U) between rows of tions and indicator lights. modules. 00 00 00 00 m s E sac D C 3 0 0U 0 0 B O LU - A IMN �m Fx_1 sX T Q Lip m O O 0 0 o O 009938 012286 Figure 4-27. Installing Retention Clips(2 of 3) Figure 4-29.DCB(left)and EX Module(right) Connections To install retention clips: 1. See Figure 4-28. Align holes in retention clip (V) A Battery Connection Power Port with stud (W)and mounting hole(X). B CommOut Port v C Commin Port X W a D SoC LED ® E Status LED 0 1. See Figure 4-30. Locate multicolored CAT5 cables attached to battery power cable harness on body (Y)and top, rear battery module (Z). O 2. Connect Gray CAT5 cable to battery module COM Q IN (A) 009939 3. Connect Black CAT5 jumper to battery module Figure 4-28.Retention Clips.(3 of 3) COM OUT(B). 2. Apply gentle pressure to ensure all grounding tabs NOTE: Black CAT5 jumper is found in hardware kit. and clips make firm contact with case. Installation Manual for Generac PWRcell Battery 25 Installing PWRcell Battery 4. Connect the other end of Black CAT5 jumper to COM IN port(D)on front battery module (C). 5. Connect Blue CAT5 cable to COM OUT port(E). 6. Connect the other end of Blue CAT5 cable to COM IN port(G) on lower, rear battery module(F). L Y C 012 Oz Z J / D � 01 08 kITil 17, E ' B O ® M 009941 Figure 4-31.Module COM Cabling(2 of 2) I Gray CAT5 J Blue CAT5 a K Orange CAT5 L Black CAT5 Jumpers 00 e • Connecting Battery Power Cables I e . Electrocution. Never reach into port or touch battery terminals with hands or tools. Doing so F will result in death, serious injury, equipment or 01 property damage. (000639) G OR 1. See Figure 4-32. Remove gray rubber cap (A) from each module power port. 2. Plug black power cable connectors into battery H module power ports(B). 009940 Figure 4-30. Module COM Cabling(1 of 2) ®r 7. See Figure 4-31. Continue connecting the remain- ing battery modules.While installing CAT5 cables: • Work from top to bottom. • Connect battery modules sharing a shelf with a ® © 0 black jumper cable (L) going from the rear battery COM OUT port to the front battery COM IN port. Oq ,� ICU • Do not install a CAT5 cable to the last battery module's COM OUT port(M). • Remaining COM cables can be left disconnected. OOOO 009942 • Unused CAT5 jumpers should be kept in safe place _ ^ for future module upgrades. Figure 4-32. Power Cable Ports 26 Installation Manual for Generac PWRcell Battery Installing PWRcell Battery 3. See Figure 4-33. Install loop jumper (C) on every Installing Cover unused power cord connector(D). 1. See Figure 4-35. Place cover(A)upright in front of unit. 2. Verify all cables are tucked in and clear of frame. 3. Slide cover straight back until it engages with body (B). 4. Verify all angled guides are tucked inside body. ® o The back edges of the cover should be against the 0 rubber gasket along their entire length(C). NOTE: Do not force cover into place. A Lift straight up. Pins on cover will automatically O engage and hold the top of the cover in place. 6. Gently push in on the bottom of the cover. This will ® lock the bottom of the cover in place. A oossas 7. Install two M4X16 mm screws (D) and torque to 13 Figure 4-33. Installing Loop Jumper in-Ib (1.47 Nm). 4. See Figure 4-34. Tie unused loop jumpers (E) to To remove the cover: wiring chase baffle slot(F)for future use. 1. See Figure 4-35. Remove the two M4X16 mm NOTE: If a battery module needs to be replaced, spare SEM (D) securing cover(A)to body(B). loop jumpers can be used to keep PWRcell Battery run- 2. Lift cover up. ning until the replacement battery module gets installed. 3. Pull cover bottom out slightly and lower to the floor. 0 F 0 pop C o E ® � I c JO O 0 009944 ® .I Figure 4-34. Unused Loop Jumpers D .a 009919 Figure 4-35.Installing Front Cover(OR model shown) Installation Manual for Generac PWRcell Battery 27 Installing PWRcell Battery Upgrading PWRcell Battery 10. Add the new battery module(s)to the stack by con- necting the battery power harness and appropriate See Figure 4-35. Inside of the PWRcell Battery, battery Cat 5 communication cables. See Installing Bat- modules are stacked 2-deep on three levels, allowing for fery Modules for more information. up to 6 modules to be connected in a series. In systems with less than 6 modules, a PWRcell Battery can be Maximizing Battery Capacity After Upgrade upgraded with additional modules. To maximize battery capacity after adding new battery Whenever upgrading a PWRcell Battery with additional modules, allow the battery to charge to 100%. Leave the modules: system set to Priority Backup or Clean Backup system • A Vset Function must be performed. See Using mode for several days to allow the battery cells to bal- Vset Function. ance. • A module spacer must be installed on any single module shelf. See Installing Module Spacer (PWRcell M3 and PWRcell M5 only). Using Vset Function NOTE: Perform Vset before installing new modules. NOTE: To perform Vset, the existing battery modules must be at higher voltages than the new modules. Vset procedure works by discharging existing battery modules to match new module voltage(s). 1. Ensure inverter system is set to Priority Backup or Clean Backup system mode. 2. Prior to installing, measure the voltage of each new battery module at the module main power termi- nals using a digital multi-meter and record the volt- age values for each. NOTE: If installing more than one module, where those module's voltages differ by more than 300 mV(0.3 Volts) from each other, perform the Vset procedure individually for each module to ensure proper cell balancing. 3. Navigate to the PWRcell Battery device page and press the center button to access the main menu; then select'Mod. Settings.' 4. Navigate to the last setting, 'Module Vset', and select using the center button. 5. Enter the voltage value measured from the new module(s) if different from the default value and 'Save'changes. 6. From the PWRcell Battery device page, press the center button. 7. Select 'Start Vset' from the PWRcell Battery main menu. 8. The battery will start discharging. Look for the Bat- tery Status LED to be green, rapid flashing. NOTE: The system will automatically stop discharging and disable the battery once the existing modules dis- charge to the voltage set. 9. Once Vset has finished, check existing module voltages at their module main power terminals with a digital multi-meter to ensure they match the volt- ages of the new module(s). 28 Installation Manual for Generac PWRcell Battery Commissioning Section 5: Commissioning General Information Configure Battery NOTE: Register the PWRcell Inverter for commissioning 1. Using the left or right arrow keys on the inverter at https://pwrfieet.generac.com. control panel, navigate to the PWRcell Battery Before commissioning PWRcell Battery verify all wiring is device page and press the center button. correct and secure and that the front cover is securely in 2. Select'Mod. Settings'to access battery setpoints. place. For more information,.see: 3. Configure Mod. Settings setpoints as desired. See • Installing REbus wiring Table 1 for a description of settings. • Installing Battery Modules NOTE: PWRcell Battery will auto-detect the number of . • Installing Retention Clips lithium-ion modules. • Connecting Battery Power Cables Enable Battery • Installing Cover 1. Turn the PWRcell Battery Disconnect ON. PWRcell systems installed in one and two family dwelling 2. Select Enable and confirm on the PWRcell Inverter units shall be commissioned as follows: control panel device page. 1. Verify system is installed in accordance with the installation instructions in this manual and all local, Confirm Island Mode is Enabled code requirements. 1. Using the inverter control panel, select Mod. Set- 2. Provide a copy of the PWRcell Battery installation tings on the PWRcell Inverter device page. and owner's manual to the system owner. 2. Ensure Enalslanding is set to'on'. 3. Provide training to the system owner on the proper . 3. If using an external automatic transfer switch, refer ,operation and maintenance of the battery: to the Generac PWRcell Inverter Installation Man- 4. Provide a label on the installed system containing ual and the PWRcell ATS Manual for switch wiring contact information for the qualified maintenance and configuration. and services providers. IMPORTANT NOTE: Island mode must be enabled for NOTE: See the Generac PWRcell Inverter Owner's inverter to provide backup power during outages. Manual for complete information on enabling the inverter and using the display and keypad, as well as information Operating Modes, Charging on the different operational modes and their uses. Parameters, and Setpoints Commissioning Procedure The PWRcell Battery's internal control electronics come For complete system commissioning, please reference Preprogrammed for the safe and effective charge and the Quick Start Commissioning guide included with the discharge of the battery modules. PWRcell Inverter and the PWRcell Inverter Installation The PWRcell System supports multiple storage interac- Manual. five system modes. For complete information on the dif- For multi-inverter system commissioning, stop here and ferent system modes and how to select them, see the reference Multi-Inverter System Commissioning in the Generac PWRcell Inverter Owner's Manual. PWRcell Inverter Installation Manual. Reference Table 1 below for detailed list of PWRcell Bat- Commissioning the PWRcell Battery REbus device: tery settings. 1. Turn the REbus DC disconnect for the PWRcell Battery to the ON position at the inverter. 2. Enable the -inverter from the PWRcell Inverter device page, using the inverter control panel. NOTE: Enabling the PWRcell Inverter builds voltage,on- REbus allowing for device communications. Installation Manual for Generac PWRcell Battery 29 Commissioning Battery Settings TABLE 1. Battery Settings Setpoint Range Default Description Channel for REbus communications.All devices in a PLM Channel 1-12 1 system must use the same channel(except REbus Beacon). Minimum state of charge(SOC)absolute-this is the MinSocAbsl 0-20% 2 percentage of charge the battery will discharge to while the system is in Island Mode. MaxSocAbsl 10-100% 100 Maximum state of charge(SOC)absolute-this is the percentage of charge the battery will charge to. Minimum state of charge(SOC)reserve-this is the MinSocRsry 0-90% 30 percentage of charge the battery will discharge to using Self-Supply Mode. Maximum state of charge(SOC)reserve-when bat- tery SoC reaches this value, PV power is diverted MaxSocRsry 10-100% 100 from charging the battery to powering local loads sav- ing battery capacity for future charging.When excess power might otherwise be clipped,this extra capacity can be used to absorb peak PV. The battery stack will charge up to this current limit DschgCurLim 0—35 Amps 35 continuously after power has been converted from REbus. The battery stack will charge up to this current limit ChgCurLim 0—35 Amps 35 continuously after power has been converted from REbus. Length of time the battery will sleep for upon reaching Sleep Time 1 —720 Minutes 60 its MinSocAbsl while in island mode.Battery will wake up every hour for four minutes to power search. Power search setting is the length of time the battery PowSrch Time 10—900 Seconds 240 will wake up from sleeping to search for PV power on REbus for charging. Voltage level the battery will drain its modules to upon Module Vset 40.0—55 Volts 46.5 initiating the Vset procedure.See Upgrading PWR- cell Battery. 30 Installation Manual for Generac PWRcell Battery Commissioning Decommissioning Decommissioning Plan The owner of the PWRcell Battery and the qualified VtIARNING Generac Service Dealer shall prepare a written Environmental Hazard.Always recycle batteries at an decommissioning plan that provides the overview of the official recycling center in accordance with all local decommissioning process developed specifically for the Laws and regulations. Failure to do so could result in battery that is to be decommissioned. The environmental damage,death, or serious injury. (000228). decommissioning plan shall provide the requirements and methods necessary to safety discharge the stranded energy in battery modules and the proper removal from gWARNING the installation site including the transportation and Environmental Hazard. Decommissioning must be recycling process for the battery modules. performed by qualified personnel. Decommissioning After the battery has been decommissioned, a performed by unqualified personnel could result in environmental damage, death,or serious injury. decommissioning report shall be prepared by the owner (000654) of the system and the qualified Generac Service Dealer indicating the date the battery was decommissioned, the PWRcell Battery modules will be required to be final results of the decommissioning process, any issues decommissioned at the battery module end of life stage that were identified during the decommissioning process, or if the PWRcell Battery will be removed from the and the required measures taken to resolve those issues. premises in accordance with these, instructions, the requirements in NFPA 855, and all applicable code requirements. The authority having jurisdiction (AHJ) Battery Recycling shall be notified prior to the decommissioning of the Always recycle batteries in accordance with local laws battery. and regulations. Contact your local solid waste collection site or recycling facility to obtain information on local recycling processes. For more information on battery recycling, visit the Battery Council International website at: http://batterycouncii.org. Installation Manual for Generac PWRcell Battery 31 Commissioning This page intentionally left blank. 32 Installation Manual for Generac PWRcell Battery Wiring Diagrams Section 6: Wiring Diagrams PWRcell M3 O O Contactors BLACK RED I Snubber Battery String I DC - - - - - 1/O Switch — Black-start battery ! I O ! O ! o 1 B REbus 380v DC ! O a O o ! I ! ! ! ! REbus cable entrance Module Cat 5 COMs Cable -----------------------------------------------------------------------------• Module Spacer Front Module 2I=nn I -ol oo=1 , Module 1, Module 3 ;' Top o o o 00 + © g00 00 00 ° 9°° 00 ------------------------- ---------- 45: Back 009945 Installation Manual for Generac.PWRcell Battery 33 Wiring Diagrams PWRcell M4 O O BLACK Contactors RED O O Snubber i Battery String — — — — — DC� 1/0 Switch — Black-start battery Pee®®9 e d O 9 O. I q I I B REbus 380v DC 1 O o 0 1 I 1 I I I 1 I I REbus cable entrance ModuleCAT5 COMB Cable --------------------------------------------------------------------------- Front 1 Module 1 Module 3 1 o 0 X00 ® �00 00 0 + �°° 00 + 0 � 1 ModuleJum ers ' �% Top 14 P Module 2 Module 4 , F=---T I 00 + Q°° 00� X00 +� Back 009946 34 Installation Manual for Generac PWRcell Battery ' Wiring Diagrams PWRcell M5 O O Contactors BLACK RED O O i Snubber Battery String °C� 1/0 Switch — Black-start battery r®-ee9 I I s O I O O O I � y 1 B REbus 380v DC I O o O --------------------- I I I I I 1 - REbus cable entrance Module CAT5 COMs Cable ----------------------------------------------------------------------------• Module Spacer Front Module Jumer Module 2 Module 4 , o � o 1,00 � o I 01c, 00 + 00Module 1Module 3 Module 5Top o 00 g°° 00 00 �-�°��O 00 L_____________________________ _► ---_____________- Back 009947 Installation Manual for Generac PWRcell Battery 35 Wiring Diagrams PWRcell M6 0 0 BLACK Contactors RED 0 0 i Snubber Battery String - — — — - - °C� 1/0 Switch — Black-start battery P� �9 � I d O I 0 I B 0 O 0 REbus 380v DC s i o REbus cable entrance Module Cat 5 COMs CableL---=------------------------------------------------------------------------; Front ' Module 1 Module'3 Module 5 o I 00 +© �°0 00o 00 +� P P°° 100 Module 2 Module 4 Module 6 Top � � o +:�q°° 00 00 +° q°° 00 :e----------------------------- — --1 L------------------------------ - --L •----------------.: Bac oossas 36 Installation Manual for Generac PWRcell Battery Troubleshooting Section 7: Troubleshooting General Troubleshooting Some of the more common problems are listed in the table below. This information is intended to be a check or verification that simple causes can be located and fixed. It does not cover all types of problems. Procedures requiring in-depth knowledge or skills should be referred to a Generac Authorized Service Dealer. Table 7-1. General Troubleshooting Guide Problem` ; Possible Cause Solution Battery Disconnect Switch OFF Turn battery disconnect switch ON. Measure stack voltage using digital multi-meter at screw Battery stack voltage is zero volts/ terminals on either side of fuse blocks or at main power incomplete series connection harness connector. If zero volts measured,ensure looped jumpers are installed at any vacant module positions,and ensure power plugs are fully seated at each battery module. Battery remains in Double check Cat 5 sequence from module to module. Waiting state,or shows "Battery Not Ready' Battery comms cables are out of Make sure module is not upside down. sequence or not fully connected Ensure Cat 5 cables are fully seated. Unplug one battery module before opening fuse holders. Battery fuse(s)are blown Remove fuses and test each fuse for continuity using a digital multi-meter. Inverter disabled Enable inverter. REbus not operating Verify REbus is operating correctly. DC disconnect OFF Verify inverter is disabled,"then tum DC disconnect ON. Battery not recognized by Loose connection Verify connections are'secure. inverter Insufficient voltage Measure voltage at the REbus terminals;there should be at least 360V between RE+and RE-. Inverter and battery not using same Set inverter and battery to same PLM channel. PLM channel If problems persist, contact the nearest Independent Authorized Service Dealer(IASD) or Generac Customer Service at 1-888-436-3722(1-888-GENERAC). Installation Manual for Generac PWRcell Battery 37 Troubleshooting r This page intentionally left blank. 38 Installation Manual for Generac PWRcell Battery This page intentionally left blank. GENERAC® Part No.A0000639748 Rev.C 4/14/2021 Generac Power Systems, Inc. ©2021 Generac Power Systems, Inc. All rights reserved. S45 W29290 Hwy.59 Specifications are subject to change without notice. Waukesha,WI 53189 No reproduction allowed in any form without prior written 1-888-GENERAC(1-888-436-3722) consent from Generac Power Systems,Inc. www.generac.com Ln Intertek tertek 3933 US Route 11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 www.intertek.com 0 'Vedfication of Conf®r oty On the basis of the,evaluations undertaken,the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. /Applicant Name&Address Pika Energy Inc 35 Bradley Dr.,Stop#1, Westbrook, ME 04092 USA Product(s)Tested Grid Support Utility Interactive Inverter Model(s) X7602,X7603,X11402,X11403 Brand name : Pika Energy,Generac Power Systems,Generac. Software Version:(X7602,X11402) 13120 + Software Version:(X7603,X11403) 12982 Checksum X7602-0x2849;,X7603-OxFA6B;X11402-Ox29OA; X11403- OxFB2C Relevant Standards)/Specification(s) Inverters, Converters,Controllers And Interconnection System Equipment For Use With Distributed Energy Resources JUL 1741:2010 Ed.2(Supplement SA)+R:15Feb2018' s With the source requirements document(SRD)—Hawaii Rule No. 14H Interconnection of Distributed Generating Facilities with the Company's Distribution System HECO SRI)V 1.1 Electric Rule No.21 Generating Distribution System And ISO New England , I Grid Support Utility Interactive Interoperability Optional Functions: Prevent Enter Service and Limit Active Power(CA Rule 21, Phase 3,functions 2 and 3) i. s Verification Issuing Office Name& Intertek,3933 US Route 11,Cortland,NY 13045, USA j Address Date of Test(s) : 05/17/16 to 02/19/2020 Verification/Report Number(s) : 102589015CRT-001c- \NOTE:This verification is part of the full test report(s)and should be read in conjunction with it. ti This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreemer t for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sole or advertisement of the tested material,product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample testedlinspected. This Verification byitse/f does not imply that the material,product or service is or has ever been under an Intertek certification program. .19W Signature: Name:Aditya Iyer Position:Project Engineer Date:May-19-2020 vjww.hAmftk.com GFT-OP-11 e(7-March-2017) Interte htertek Cortland, 3933 US Route 11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 www.intertek.com Test Summary Pika completed the following tests according to UL1741 SA. Section Number Description SAB Anti-Islanding Protection-Unintentional Islanding With Grid Support Functions Enabled SA9 Low and High Voltage Ride-Through SA10 Low and High Frequency Ride Through SA11 Normal Ram SAI 1 Soft-Start Ram SA12 Specified Power Factor SA13 Volt-Var Mode Active Power Priori SA13 Volt-Var Mode Reactive Power Priori SA14 Frequency-Waft SA15 I Volt-Watt SA17 Disable Permit Service SA18 I Limit Active Power IIA. I Reactive Power Capabilities Heco Ratings for X7602,X7603: Max.Input Volta a 420 Vdc Input Voltage Range 360-420 Vdc Max.Input Current 20 A Max.Input Short Circuit Current 30A Output Voltage Range 106-132 Vrms L-N Frequency Range 57-63Hz Nominal Output Volta a 120/240Vrms Nominal Frequency 60 Hz Max.Continuous Output Current 32 Arms Ratings for X11402,X11403: Max.Input Voltage 420 Vdc Input Volta a Range 360-420 Vdc Max.Input Current 30A Max.Input Short Circuit Current 30A Output Voltage Range 106-132 Vrms L-N Frequency Range 57-63Hz Nominal Output Voltage 120/24008Vrms Nominal Frequency 60 Hz Max.Continuous Output Current 32 Arms Manufacturer's Stated Accuracy for X7602,X7603,X11402 X11403 Pika states the following accuracies according to the require ents of UL1741 SA. Description Value Manufacturer's stated AC volts-e accuracy %Vac) 2% Manufacturer's stated DC voltage accuracy %Vdc) 2% Manufacturer's stated AC current accuracy %Aac) 2% Manufacturer's stated frequency measurement accuracy Hz or%Hz 0.05Hz Manufacturer's stated output Power accuracV UW or W 250W Manufacturer's stated reactive power accuracy %or Var 250Var Manufacturer's stated Power factor accuracy 0.02 Manufacturer's stated time accuracy(sec) 0.1sec 1!f&fRtfli6.[Cl�r� T>2E@ GFIT-0PIIe(74Aarcft-2aM intertek Intertek 3933 Us Route 11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 vmmintertek.com Grid Support Function Parameters Pika used the following parameters during the testing of the grid support functions according to UL1741 SA. SA9 Low/High Volta a Ride-Throu h for X7602, X7603,X11402,X11403 Operating Voltage at Point Operating Mode Ride Default Range of Range of Region of Through Maximum Adjustability Adjustability Interconnection Until(s) Trip Time Voltage Trip Clearing (%of Nominal (s) Magnitude Time(s) Voltage) (%of Nominal Voltage) O 2 V>120[121] Mandatory Operation N/A 0.16 N/A N/A 120W>100[117] Man atory 0.92 110-1201-13 Operation/Momentary Cessation CO 1102!V>100[107] Continuous Operation N/A N/A N/A N/A CO 100>\J-a88[91] Continuous Operation N/A N A N/A N/A V1 88>Va70[73] Mandatory Operation 20 21 50-88 21-50 V2 70>Va50[53] Mandatory Opeartion 0-20- 11-2 50-88 11-50 UV3 V<50 Momentary Cessation N/A 2 N/A 0.5-21 SA10 Low/High Fre uenc Ride-Through for X7602,X7603,X11402, X11403 Operating Frequency at Operating Mode Ride Default Range of Range of Region Point of Through Maximum Adjustability Adjustability Interconnection Until(s) Trip Time Frequency Clearing s Time s OF2 f>64 Permissive Operation None 0.16 62-66 0.16-1000 f>65[L+M][65.925 OF1 64af>63 Mandatory Operation 20 21 61-66 21-1000 65ah63[L+M] 65.925 High 60.54562[60.1] Mandatory Operation 299 300 60.1-62 N/A Frequency 1 (HFI) NOF 63e>60[60.425] Continuous Operation Indefinite N/A N/A N/A NUF 60>&57[58.875] Continuous Operation Indefinite N/A N/A N/A Low 57<f558.5[59.9] Mandatory Operation 299 300 57-59.9 N/A Frequency 1 LF1 UF1 57>fa56 Mandatory Operation 20 21 50-59 21-1000 57>fa50[L+M] 50.075 UF2 56>f Permissive Operation None 0.16 50-57 0.16-1000 50>f L+M ldtfww n1W-rfek cE1m GFT-0P-11e,ter-March-2017) Y !f htertek Intertek 3933 Route 11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 www.intertek.com SAI 1 Normal Ramp Parameters for X7602,X7603,X11402,X11403 Description Value Output current rating(Aac) 32 Minimum normal ramp-up rate(%bated/sec) 1 Maximum normal ramp-up rate(%[rated/sec) 100 Output current range of function(%[rated) 0%to 100% Ramp rate accuracy °/abated/sec 2% SAI 1 Soft-Start Ramp Parameters for X7602,X7603,X11402,X11403 Description Value Output current rating(Aac) 32 Minimum soft-start ramp-up rate(°/abated/sec) 0.1 Maximum soft-start ramp-up rate(%Irated/sec) 100 Output current range of function(°/abed) 0%to 100% Ramp rate accuracy Wrated/sec 2% SAI 2 Specified Power Factor Parameters for X7602,X7603 Description Value Apparent power rating(VA) 7600 Output power rating(W) 7600 DC Input voltage range with SPF enabled(Vdc) 380410 Nominal AC•voltage(Vac) 120/240 Vrms AC voltage range with SPF enabled(Vac) 102-138 Manufacturer's stated AC voltage accuracy(%Vac) 2% Manufacturer's stated DC voltage accuracy(%Vdc) 2% Active power range of function(W) 500-7600 Manufacturer's stated Power Factor accuracy 0.02 Power factor settling time(sec) 0.5 Minimum Inductive(underexcited)Power Factor -0.1 Minimum Capacitive overexcited Power Factor 0.1 SA12 Specified Power Factor Parameters for X11402,X11403 Description Value Apparent power rating(VA) 11400VA Output power rating(W) 1140OW DC Input voltage range with SPF enabled(Vdc) 380-410 Nominal AC voltage(Vac) 120 L-N AC voltage range with SPF enabled(Vac) 102-138 Manufacturer's stated AC voltage accuracy(%Vac) 2% Manufacturer's stated DC voltage accuracy(%Vdc) 2% Active power range of function(W) 500-11400 Manufacturer's stated Power Factor accuracy 0.02 Power factor settling time(sec) 0.5 Minimum Inductive(underexcited)Power Factor -0.1 Minimum Capacitive overexcited Power Factor 0.1 www.liftftk.com GFT-OP-11e(7-Nl 2e17) htertek Intertek 3933 US Route 11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 www.intertek.com SAI 3 Volt/Var Parameters for X7602,X7603 Description Value Apparent power rating(VA) 7600 Output power rating(W) 7600 EUT Input voltage range with Q(V)function enabled do 380-410 Nominal AC EPS voltage(V) 120/240 Vrms AC EPS voltage range with function enabled(Vac) 102-138 Reactive Power Accuracy(Var) 250 Maximum Ramp Rate(VAr/sec) 1000 Max rated reactive Power(capacitive,overexcited) -6460 Ar Max rated reactive Power(inductive,underexcited) Ar 6460 Maximum slope(VArN) 1794 Deadband Range(Vac) 117.6-126 Settling Time sec 1-90 SA13 Volt/Var Parameters for X11402 X11403 Description Value Apparent power rating(VA) 11400 Output power rating(W) 11400 EUT Input voltage range with Q(V)function enabled Vdc 380-410 Nominal AC EPS voltage(V) 120 L-N AC EPS voltage range with function enabled(Vac) 102-138 Reactive Power Accuracy(Var) 250 Maximum Ramp Rate(VAr/sec) 1000 Max rated reactive Power(capacitive,overexcited) Ar -9690 Max rated reactive Power(inductive,underexcited) Ar 9690 Maximum slope(VArN) 2691 Deadband Range(Vac) 117.6-126 Settling Time sec 1-90 w@3t4y.!u1'terfnk.cam GFT-OP-11e(7-March-20,17] htertek Intertek 3933 US Route Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311www.intertek.com SA14 Fre uenc -Watt Parameters for X7602,X7603 Description Value Output power rating(W) 7600 AC frequency range with function enabled(Hz) 57-63 Manufacturer's stated frequency measurement accuracy Hz 0.05 Manufacturer's state power accuracy(%W) 250 Settling Time(sec) 0.05-3 Adjustment range of the start of frequency droop(Hz) 60.02-61 Maximum slope of frequency droop(%Prated/Hz) 100 Minimum slope of frequency droop(%Prated/Hz) 25 Minimum Adjustment range of the rate of return to continuous operation(%Prated/sec 1 Maximum Adjustment range of the rate of return to continuous operation(%Prated/sec 100 SAI 4 Frequency-Watt Parameters for X11402,X11403 Description Value Output power rating(W) 11400 AC frequency range with function enabled(Hz) 57-63 Manufacturer's stated frequency measurement 0.05 accuracy Hz Manufacturer's state power accuracy(%W) 250 Settling Time(sec) 0.05-3 Adjustment range of the start of frequency droop(Hz) 60.02-61 Maximum slope of frequency droop(%Prated/Hz) 100 Minimum slope of frequency droop(%Prated/Hz) 25 Minimum Adjustment range of the rate of return to 1 continuous operation(%Prated/sec Maximum Adjustment range of the rate of return to 100 continuous operation(%Prated/sec t+uia6w.Intertef mmm GIFT-OP-31le t7-��a Z017� V i r Intertek htertek 3933 US Route11 Cortland,NY 13045 Total Quality.Assured. Telephone:607-753-7311 www.intertek.com SAI 5 Volt-Watt Parameters for X7602,X7603 Descri tion Value Output power rating 7600 AC voltage range with function enabled ac 108-138 Nominal AC voltage ac 120/240 Vrms Manufacturer's stated AC voltage accuracy %Vac) 2% Manufacturer's stated output power accuracy W 250 Manufacturer's stated time accuracy sec 0.1 Settling time sec 0.5-90 Adjustment range of the start of active power reduction ac 123.6-127.2 Adjustment range of the stop of the curtailment function ac 127.2-144 Maximum slope of active power reduction(%Prated/V 27.77 Minimum slope of active power reduction(%Prated/V 5.95 Adjustment range of delay before return to normal operation sec 1-600 Adjustment range of the rate of return to normal operation %Prated/seC 0.16-100 SAI 5 Volt-Waft Parameters for X11402,X11403 Description Value Output power rating(W) 11400 AC voltage range with function enabled(Vac) 108-138 Nominal AC voltage(Vac) 120 L-N Manufacturer's stated AC voltage accuracy(%Vac) 2% Manufacturer's stated output power accuracy(W) 250 Manufacturer's stated time accuracy(sec) 0.1 Settling time(sec) 1 0.5-90 Adjustment range of the start of active power reduction 123.6-127.2 ac Adjustment range of the stop of the curtailment 127.2-144 function ac Maximum slope of active power reduction(%Prated/V) 27.77 Minimum slope of active power reduction(%Prated/V) 5.95 Adjustment range of delay before return to normal 1-600 operation sec Adjustment range of the rate of return to normal 0.16-100 o eration %Prated/sec r wwInitedBIL OM. OFT-OF 19e