Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
47826-Z
��o�oSUFFUty Town of Southold 2/3/2023 0 P.O.Box 1179 53095 Main Rd 4,� �oo� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43812 Date: 2/3/2023 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 575 Theresa Dr.,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-15-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/14/2022 pursuant to which Building Permit No. 47826 dated 5/18/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Waitz,Jacob&Danielle of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47826 12/8/2022 PLUMBERS CERTIFICATION DATED ut oriz Signature SOfFa1Itr TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • � . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47826 Date: 5/18/2022 Permission is hereby granted to: Waitz, Jacob 575 Theresa Dr Mattituck, NY 11952 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 575 Theresa Dr., Mattituck SCTM # 473889 Sec/Block/Lot# 115.-15-5 Pursuant to application dated 4/14/2022 and approved by the Building Inspector. To expire on 11/17/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Build in Inspector. pF SO!/jyQlo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a sean.deviin(cD-town.southold.ny.us Southold,NY 11971-0959 Q a �yC4UNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jacob Waitz Address: 575 Theresa Dr city:Mattituck st: NY zip: 11952 Building Permit* 47826 section: 115 Block: 15 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: EmPower Solar License No: 65990ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 16kW Roof Mounted PV Solar Energy System w/ (40) SPR 40OW Modules, AC Disconnect, Combiner Notes: Solar Inspector Signature: Date: December 8, 2022 .01 S. Devlin-Cert Electrical Compliance Form ho�aOF so(/Tl'7 6 5-757 DEP` - - - — f f TOWN OF SOUTHOLD BUDING T. ' `ycourm a 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: dt_�.�r ALL n ce-cl DATE l INSPECTOR f1f s 0 q7 8 2,6o 577.5_ -7-/t dp/,es4<t� # # TOWN OF SOUTHOLD BUILDING DEPT. °`ycourm e�' 631-765-1802 INSPECT-ION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: No &c- c-' ,M e G'n G A a, ec DATE INSPECTOR �� OF SOUTypID 7��(0 X575 � - - -- # # TOWN OF SOUTH LD lWP O BUILDIN DEPT. �ycourm�� 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) 15aLECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: r N'g-r, a. GTi2� ce DATE INSPECTOR �� SOGTyolo -- # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] NSULATIOWCAUULKING [ ] FRAMING /STRAPPING [ FINAL�p��✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR Gregory Sachs, PE 4589 Austin Blvd., Island (516)-544-4592 Park, NY 11558 permitting@empower-solar.com October 17th, 2022 Town of Southold Building Department 54375 Route 25 Southold, NY 11971 �� �F- QC1 19 Permit#:47826 �t - 575 Theresa Drive - Mattituck, NY 11952 Section: 115.00 Block: 15.00 Lot: 005.000 To Whom It May Concern: The Solar Electric installation at 575 Theresa Drive, Mattituck, NY 11952 (Waitz Residence) has been inspected and meets the New York State Building Code standards for construction and the provisions of ASCE 7.The solar panels have been secured to the roof as per the manufacturer's attachment detail shown on the approved drawings, and are in compliance with the structural engineer's requirements.The project is consistent with the specifications set forth in the permit application. Sincerely, .1 OR' SAC O LLr O w o• , 0 MSED PRo CD Gregory Sachs, PE FIELD INSPECTION REPORT DATE COMMENTS, �jv FOUNDATION(1ST) Ny ------------------------------------ �o o FOUNDATION(2ND) vl � y ROUGH FRAMING& PLUMBING (� 1 7 - r y INSULATION PER N.Y. STATE ENERGY CODE _ b n FINAL ADDITIONAL COMMENTS 5 Eo 2Z- 001 V-� l0 lb - E +O z IOL9010 1 C.P.t oh W O y `V O � e b �3 oSUFFgiK�pG TOWN OF SOUTHOLD—BUILDING DEPARTMENT W, Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ?y o� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtowpEy.go ?�ol,�•:ya Date Received APPLICATION FOR BUILDING PERMIT • For Office Use Only APR 1 4:2022 PERMIT N0. Building Inspector: 41 '- K BUILDING DEPT. Applications and forms must be filled out in their'entirety.Incomplete TOWN OF SOUTHOl1) applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 4/13/2022 OWNER(S)OF PROPERTY: Name: Danielle and Jacob Waitz SCTM#1000- i-1-5.-O-0.7-1-5-..0-0=0-0-5,-0-0-0— Project _1.5.0.Oe1.5_.00=0Q5000Project Address:575 Theresa Drive, Mattituck, NY 11952 Phone#: (516)-852-0690 Email: artisannf@gmail.com Mailing Address: 575 Theresa Drive, Mattituck, NY 11952 CONTACT PERSON: Name: Sara McCaffrey Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (51_6_)_54 4592 Email:permitting@empower-so1ar.com DESIGN PROFESSIONAL INFORMATION: Name: Gregory D. Sachs Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: (516)-544-4592 1 Email: permitting@empower-solar.com CONTRACTOR INFORMATION: Name: EmPower CES, LLC. Mailing Address: 4589 Austin Blvd., Island Park, NY 11558 Phone#: 516)-544-4592 Email: permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Xother Solar PV $ 49,493.96 Will the lot be re-graded? ❑YesX]No Will excess fill be removed from premises? ❑Yes NNo 1 PROPERTY INFORMATION Existing use of property: Residential 1 Family Intended use of property: Residential 1 Family Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes N No IF YES, PROVIDE A COPY. ®Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by. Chapter 236 of the Town Code.'APPLICATION IS.HEREBY MADE to the`Building Department for the issuance of a Building Permit pursuant to the'Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or demolition as herein described.The applicant agrees-to comply with all applicable laws,ordinances,building,code;,. housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are ' punishable as a Class A misdemeanor pursuant to Section 21.0.45 of the New York State Penal Law: Application Submitted By(print name): Sara McCaffrey X]Authorized Agent ❑Owner Signature of Applicant: Date: 4/13/2022 STATE OF NEW YORK) SS: COUNTY OF ) Sara McCaffrey being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this l day of [ 171 ,20?21 o5v. < ohnson NOTARY PUBLIC, A E OF NEW YORK R*ir2ti No,"0`1,106374726 PROPERTY OWNER AUTHORIZ Qualified In Queens County fission Expires May 7.2022 (Where the applicant is not the ow -- I, Jacob Waitz residing at 575 Theresa Drive, Mattituck, NY 11952 do hereby authorize Sara McCaffrey to apply on my behalf to the Town of Southold Building Department for approval as described herein. kffh� wat 4/13/2022 %wnees Signature Date Jacob Waitz Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Y F Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 . Telephone (631) 765-1802 - FAX (631) 765-9502 jigrogerr(ftoutholdtownrimov — seandRsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 4/13/2022 Company Name: EmPower CES, LLC. Name: Timothy Crotty License No.: ME-65990 email: ermittin em ower-solar.com Address: 4589 Austin Blvd., Island Park, NY 11558 Phone No.: (516)-544-4592 JOB SITE INFORMATION (All Information Required) Name: Jacob Waitz Address: 575 Theresa Drive, Mattituck, NY 11952 Cross Street: . Phone No.: (516)-852-0690 Bldg.Permit#: W a , �. email: artisannf@qmail.com Tax Map District: 1000 Section: 115.00 Block:15.00 Lot: 005.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of roof mounted solar panels (40)SPR-400w ACPV modules 16.00kW total system size Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs PERMIT # Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven W/D Smokes DW Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comments SUFFOLK COUNTY DEPT. OF HEALTH SERVICES MAP OF DEEP HOLE CREEK ESTATES FOR APPROVAL OF CONSTAUC71ON ONLYJAN. 28 1965 'MAP NO.4256 DATE H.S.REF•N0. NEW SUFFOLK AVE. ��yy pp 5 L 'SQyy gEE APPROVED TEMEqE EgSFTOAR�pNPpSSY R IOHENCEguN7 L`K T AF{TMENT OF SHEALTH SERVIC S, �\ 44� 00 OEkt O-WE?L 42 25 F zy 5 870-19'20NE I 182.00' �— 19.07' 1g C FD, GRADE GRADE %. O.BIE. d �� c CRETE Z '� ry m EXIST.SURFACE qE .0 a DGOVEE _ m N Q — r,0.>>> ru>mn) AO • 0L A 4a3� 27.3 r O oIN wfir, �D LOT 41 °' 26 N N� ni S.r, C• C JAvV 1 • r r ole�ua oy ou D C®P 1.91 spit I. bb 2 IN eLo'DIA. (u a� 0 TYPICAL PRECAST --- _ _ n 1 -- o (^ SEPTIC TANK $$,»� ERo(rrn WATER NO SCALE o 2a4' o TYLEACHING POOL O �'s: N NO.SCALE r •vecL. /e a� In 19.64' FQ 'B. - O.rn r N 87°-19"20'W 182.00' 0.3 S. FD: i IN �1i. u+.una+elD...wio.L+NanaN.o TTI a1..a•e A•Y4TON m tccreN r D WL G=WC L L •p rna•TNs m•o•.r•n e_w•.rlr .Sp 8 cws a•...N.nn N,..,•wA+a i.f L.ND lwve•o+t NA(o!!.E o, se �. 40 '� 27 a�:w::da.`�. ��:`�d ;�.;A .t.,o,wEgga P w.av wr fNw!• A..rY uo or r TIl.u.,o rw n,.:TnNPu•. - 9 00.lYNN••l ApfNt+AUC lf.Y•f�fnlutd,!0R➢.EgON OUAw r,ig5 011 Tf I' Dqu•an ut�,nwFtA.rA To•oa,c1.•.rtmuTlor.!a euAuoulNT r- 50' GUARANTEED TO INLAND HOMES INC. i ZONED RESIDENCE MAP OF LAND LOCATED AT AREA OF PLOT 2().020 SQFT. MATTITUCK PROP 1.1 FLOOR S0.FT. PROP 24 FLOOR SO,FT, TOWN OF SOUTHOLD COUNTY OF SUFFOLK PRP BASEMENT SO,FT.. SURVEYED FOR, PROP GARAGESO.FT. DATUM_ d3a s . (,I INLAND HOMES INC. GYM,. THERE IS NO SURFACE WATER WITHIN - FE 1 LI—g3 200 FEET OF THE PLOT. - THE OFFSETS AND DIMENSIONS SNO WN NIR(ON ARE NOT INTENDED TO GUIDE IN TN(fR(L'Q LE T -NAIL O •P.M OFFENCES.RETAININGWALLS POOLS,BUILDING .j ADDITIONS OR ANT OTHER CONSTRUCTION OR (_30' •fTAK[ ■ YOMUYtNT gANTING ANO SHDUlO THEn FDF�f NDT Bl T[4T IDLE• LOCATION 0/WAT(A UNLS E•(LL9 LICEN$EA LAND EYOR�+ - SEPTK flNq 1N0 Q4[P00.4 MOT OUlT1ANT((d 1000 1 '� 1 $ 125 ROUTE A8006UTILITY POLE uses FORsueHn(RM4Es IS S C L I FINAL LOCATION B-24' ROCKY P01NT,N.Y 1177E ►no Suffolk County Dept.of Labor,Licensing&Consumer Affairs .t HOME IMPROVEMENT LICENSE Name GREGORY SACHS a Business Name Thiscedifiesthatthe EMPOWER CES LLC DBA bearer is duly Goensed by the County of su0olk License Number:H-50211 Rosette Drago Issued: 05130.2012 Commissioner Expires: 05/01/2022 Suffolk County Dept.of Labor,Licensing&Consumer Affairs �1 MASTER ELECTRICAL LICENSE Name TIMOTHY M GROTTY Business Name This certifies that the Empower CES LLC DBA nearer is duly licensed ,y the County of suffolk License Number:ME-65990 Rosalie Drago Issued: 11112/2021 Commissioner Expires: 11/01/2023 s TM A •� 1 lh r; SunPower"' InvisiMount"' Residential Mounting System Simple and Fast Installation Integrated module-to-rail grounding ` Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even module spacing UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' rail span Pre-drilled rails and rail splice Rails enable easy obstacle management .. Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Elegant Simplicity Best-in-class system aesthetics Premium,low-profile design SunPower° InvisiMount" is a SunPower-designed Black anodized components rail-based mounting system. The InvisiMount system Hidden mid clamps and new capped,flush addresses residential sloped roofs and combines faster end clamps installation time, design flexibility, and superior aesthetics. Part of Superior System The InvisiMount product was specifically envisioned and Built for use with SunPower DC and AC modules engineered to pair with SunPower modules. The resulting Best-in-class system reliability and aesthetics New optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and mounted J-box,and wire management rail clips installation benefits—for homeowners and for installers. Combine with SunPower modules and SunPower EnergyLinkO monitoring app sunpower.com 1 . Y �2.i � 0 t• a' SunPower:�' InvisiMount"" Residential Mounting System InvisiMountComponents Module'/Mid Clamp and Rail Module'/End Clamp and Rail Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly(for DCsystemsonly) lip woo e" InvisiMount Component Details InvisiMount ••-ratinc) Conditions Mid Clamp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature -4U'C to 90°C(-40°F to 194°F) End Clamp Black anodized aluminum 6000 series 110 g(3.88 oz) • 3000 Pa uplift Max.Load(LRFD) 6000 Pa downforce Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6000 series 830 g/n1(9 oz/ft) Ground Lug 304 stainless steel Roo Supported • •• Assembly (A2-70 bolt;tin-plated copper ug) 106.5 g/m(3.75 oz) • Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal interface for other roof attachments Invisimount Component • DCapacities' Uplift 6641bf Mid Clamp — Shear 540 Ibf I Invisil'.1ount Warranties Ana Ce, Uplift 899 Ibf 25-year product warranty End Clamp — Warranties Shear 220 Ibf 5-year finish warranty Rail Moment:upward 548 Ibf-ft UL 2703 Listed _-- Moment:downward 580 Ibf-ft Certifications Class A Fire Rated Moment:upward 548 lbf-ft ---.. Rail Splice - Moment:downward 580 Ibf-h Roof Attachment Hardware Warrantie, Uplift 1000 Ibf L-foot Refer to roof attachment hardware manufacturer's documentation. Shear 390l1bf t Module frame that is compatible with the InvisiMount system required for hardware interoperability. z SunPower recommends that all EquinoxTM,InvisiMount'"",and AC module systems always be designed using the SunPower Design Tool.If a designer decides to instead use the component capacities listed in this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD) design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations,-and that a licensed Professional Engineer(PE)must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER(1-800-786-7693). sunpower.com to 2017 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. 509506 RevE All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. SUNP WERIF, A-Series A400-BLK I A390-BLK SunPower® Residential AC Module SunPower°Maxeon°Tech nolog/ Built specifically for use with the SunPower EquinoxT""system,the only fully integrated solution designed,engineered,and warranted byone manufacturer. I El Highest Power Density Available. SunPower's new Maxeonc"Gen 5 cell is 65% larger than prior generations,delivering the most powerful cell and highest-efficiency module in residential solar.The result is more power per square meter than any commercially available solar. I TE . E E Fundamentally Different. E N N larger And Better. I A. go Highest Lifetime Energy and Savings. L�:- I Designed to deliver 60%more energy over 25 years in SunPower-O Maxeon Technology real-world conditions like partial shade and high temperatures.' • Most powerful cell in home solar • Delivers unmatched reliability' 3 14Q4h • Patented solid metal foundation prevents a 130% breakage and corrosion a 12096 SunPowerup to i. 110% Go% loft more c 90% lifetime d goy§ energy Conventional Module T 70% of 60% N 0 5 10 15 20 FlIr Years of operation Best Reliability. Best Warranty. F,_, qq FactoryintegratedMicroinverter(MI) ® With more than 25 million modules deployed around • Highest-power integrated AC module the world,SunPower technology is proven to last.That's in solar • in than prior SunPower MIs why we stand behind our module and microinverter with the industrys best 25-year Combined Power and Engineered and calibrated by • SunPower for SunPower AC modules Product Warranty,including the highest Power Warranty in solar. Datasheet A-Series: A400-BLK I A390-BLK SunPower"Residential AC Module AC Flectrical Data Inverter Model:Type G/SPW R-A4(IQ 7AS) @240 VAC Peak Output Power 366 VA Max.Continuous Output Power 349 VA Nom.(L-L)Voltage/Rangel(V) 2401211-264 -- -.................... Max.Continuous Output Current(A) 1.45 Max.Units per 20 A(L-L)Branch Circuit' 11 CEC Weighted Efficiency 97.0% Noin.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms -- .._ . - Overvoltage Class AC Port III AC Port Backfieed Current 18 mA Power Factor Setting 1.0 ............... Power Factor(adjustable) 0.7 lead.1 0.7 lag. Compliarce A40'1 F I ,'-AC A390-BLK-G-AC .25-year limited power warranty 5 - - -- Warranties _25-year limited product warrant Nom.Power (Pnom)W �1o��r 390 y P Y Power Tol. +5/-0% UL 1703 547 Module Efficiency 21 3 20.9 Certifications UL 1741/IEEE dine and •UL 1741 AC Module(Type 2 fire rated) Temp.Coef.(Power) 0.29%/*C UL 62109-1/IEC 62109 Compliance .FCC Part 15 Class B Shade TOI. Integrated module-level max power point tracking --- - ---- ---- ------ ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 CA Rule 21(UL 1741 SA)' Operating Temp. lU°F to+185°F(-10'C to+85*Q (includes VOIt/Udr and Reactive Power Priority) Max.Ambient Temp. 2°F(50°C) UL Listed PV Rapid Shutdown Equipment' Max.Test Load? Wind:125 psf,6000 Pa,511 kg/rn2 back Enables installation in accordance with: Snow:187 psf,9000 Pa,917 kg/mz front NEC 690.6(AC module) Design Load Wind:75 psf,3600 Pa,367 kg/m2 back NEC 690.12 Rapid Shutdown(inside and outside the array) Snow:125 psf,6000 Pa,611 kg/m'front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Impact Resistance 1 inch(25 mm)diameter hail at 52 inph(23 m/s) When used with InvisiMount racking and InvisiMount accessories vlecnanicai Da;-: (UL 2703): Solar Cells 66 Monocrystalline Maxeon Gen 5 Module grounding and bonding through InvisiMount Class A fire rated Front Glass High-transmission tempered glass with When used with AC module Q Cables and accessories(UL 6703 and anti-reflective coating UL 2238)6: Environmental Rating Outdoor rated •Rated for load break disconnect Frame Class 1 black anodized(highest AAMA rating) PID Test Potential-induced degradation free Weight 46.5 lbs(21.1 kg) Recommended Max. 1.3 in.(33 mm) Module Spacing 1 SunPower 415 W,22.3%efficient,compared to a Conventional Panel on same-sized arrays(260 W,16%efficient,approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%lyr slower degradation rate gordan,et.al. "Robust PV Degradation Methodology and Application."PVSC 2018). g 2 Based on search of datasheetvalues from websites of top 10 manufacturers per IHS,as of ,^p January 2019. C 3#1 rank in"Fraunhofer PV Durability Initiative for Solar Modules:Part3"PVTechPower Magazine,2015.Campeau,Z.eta[."SunPowerModuleDegradation Rate,"SunPowerwhite p ❑ in.(mm) paper,2013. g -----.__ 4 Factory setto 1547a-2014 default settings.CA Rule 21 default settings profile set during B commissioning- 5 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25*C).NREL calibration standard: Long side 1.3(32) SOMS current,LACCS FF and voltage.All DCvoltage is fullycontained within the module. Short side 0.9(24) 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors; when installed according to manufacturer's instructions. 7 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. L cso wmv.a. See wwwsunpower.com/facts for more reference information. For more details,see extended datasheet www.sunpower.com/datasheets Specifications PO t C D included in this datasheet are subject to change without notice. u$1��rAyw0 lVl L R ©2020 SunPower Corporation.All Rights Reserved.SUN POWER,the SUN POWER logo, WodleFimPedvma� Type Equinox,and MAXEON are registered trademarks of SunPower Corporation in the U.S.and Please read the Safety and Installadon Instructions 531725 for additional details. other countries as well.l-800-SUNPOWER. 537616 RevA Gregory Sachs, PE had 4589 Austin Blvd, (516)-544-4115 Island Park, NY 11558 permitting@empower-solar.com April 11, 2022 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 575 Theresa Drive, Mattituck, NY 11952 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Rafter Snow Wind Max Span Layers of Roof Surface (ft) spacing Cross Section Load Speed Kneewall Collar Ties Shingles (in) (psf) (mph) East 1 16.25 16 Nominal 2x10 20 135 No No 2 West 1 16.33 16 Nominal 2x10 20 135 No No 2 Sincerely, OF NEWS Gregory Sachs, PE 9 ORY d APPROVED AS NOTED * < * DATE: =� �3LBP.#. M- FEE: . ' BY: 2N v —� NOTIFY BUILDING DEPARTMENT AT 765-1802- 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS:SS1�NP� I. FOUNDATION. - TWO REQUIRED COMPLY WITH ALL CODES OF FOR POURED CONCRETE. NEW YORK STATE & TOWN CODES 2. ROUGH - FRAMING & PLUMBING AS REQUIRED AND CONDITIONS OF 3. INSULATION TE TOWN TRA 4• FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. '9 ARD ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW n TEE�CCUP�NCY OR YORK STATE. NOT RESPONSIBLE FOR USE UNLAWFUL DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL W-.1THQUT CERTIFICATE INSPECTION REQUIRED 0F 1CCUPANCY 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER S O L A R 4589 AUSTIN BLVD ISLAND PARK,NY 11558 o TEL: 516-837-3459 RESIDENTIAL FAX: 516-706-1789 www.empower-solar.com SOLAR PROJECT THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM. MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL OWNER: Danielle&Jacob Waitz G G �OF NE�V � y - PHONE: (516)852-0690 0FLY D. S 0 _ ENGINEER OF RECORD: F _- �� SOLAR INSTALLER: GREGORY SACHS, PE F y 4-' EMPOWER SOLAR r= CD S`ria - : ' 4589 AUSTIN BLVD 4589 AUSTIN BLVD ISLAND PARK, NY 11558 2 ISLAND PARK, NY 11558 cT,� c PHONE: 516-837-3459 `';,� 98453 E PHONE: 516-837-3459 E SS\pNP j 'M 5Theresa D�; Mattituck J Y 11952 D ' D REV: DESCRIPTION: DATE: o3G PROJECT LOCATION DATA: SHEET INDEX: PROJECT NAME: Danielle&Jacob Waitz ADDRESS:575 Theresa Drive, Mattituck, ST-01 COVER SHEET '70 l NY 11952 S-01 EQUIPMENT LOCATIONS ----- !, S-02 STRUCTURAL PROJECT LOCATION: C SE-01 ELECTRICAL c 575 Theresa Drive, Mattituck, I ' NY 11952 y f CJ SCTM: 1000-115.00-15.00-005.000 4_ PROJECT#: E B 9Q�I PROJ.PHASE: PERMIT t -- DATE: B B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS MAP TITLE: APR 1 b.2022 COVER SHEET A BUILDING DEPT. A TOWN OF SOUTHOLD SHEET: ST-01 1 2 3 4 5 8 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER i SOLAR 4589 AUSTIN BLVD ISLAND PARK,NY 11558 lilivililla TEL: 516-837-3459 1 FAX: 516-706-1789 EAST ROOF-1: www.empower-soIar.com 3 24 SUNPOWER 40OW-ACPV PANELS TOTAL POWER:9.6 kW ORIENTATION:80°;PITCH:23° THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES.LLC.UNAUTHORIZED TYPE 1:FLUSH MOUNT REPRODUCTION OR DISTRIBUTION OF THIS SOLAR ACCESS:97% MATERIAL IS STRICTLY PROHIBITED WITHOUT DRIVEWAY PRIOR SPECIFIC WRITTEN PERMISSION TSRF:77% PROFESSIONAL SEAL W G � G = O of- NEW Y Y D. O WEST ROOF-1: 1 co 0O�. 16 SUNPOWER 400W-ACPV PANELS 3 F 4(/.- F �.. TOTAL POWER:6.4 kW ORIENTATION:260°;PITCH:22° U` � j N TYPE 1:FLUSH MOUNT SOLAR ACCESS:91% �P TSRF:75% El 7Q _� �O 084531\ � E E AT���`TSS\�`vP�, D D REV: DESCRIPTION: DATE: PROJECT NAME: EQUIPMENT LEGEND: SETBACK LEGEND >> WAITZ RESIDENCE MODULES 36"CLEAR PATH c PROJECT LOCATION: C 575 THERESA DRIVE MATTITUCK,NY 11952 F UTILITY METER ® 18" RIDGE SETBACK PROJECT#: F3-] INVERTERS ACCESS ROOF PROD.PHASE: PERMIT DATE: 04/11/2022 B B DESIGNED BY: ED 4❑ SOLAR DISCONNECT CHECKED BY: S 5 SCALE: NTTS TITLE: MAIN SERVICE PANEL 2 EQUIPMENT LOCATIONS 4 ROOFLAYOUT A NOT TO SCALE A SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER SOLAR 4589 AUSTIN BLVD SUNPOWER MODULES ISLAND PARK,NY 11558 COD ON INVISIMOUNT RACKING TEL: 516-837-3459 SHINGLES FAX: 516-706-1789 www.empower-sola r.com INFORMATIONTHE H /� H PROPERTY OFEMPOWE CES,LLC.UNAUTHORIZED RAFTERS REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL G G SOF NEWY F TYPICAL ROOF SECTION F , C 0_ � f 0 NOT TO SCALE r 0 SUNPOWER PANEL SPECS 084531 E MODULE POWER(WdC) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1: MAX.ATTACHMENT SPACING E ESS1ONP� SPR-400 40 SPR-A-SERIES-AC 72.2" 40.0" 1.57" 46.5 LB PORTRAIT: 5'-4" LANDSCAPE: SPR-E/X-SERIES-AC 61.4" 41.2" 1.81" 42.9 LB D D REV: DESCRIPTION: DATE: NOTES: PROJECT NAME: 1. TOTAL SYSTEM DC POWER:16.00 kW Danielle&Jacob Waitz 2. RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION MANUAL 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS PROJECT LOCATION: C AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 c 575 Theresa Drive, Mattituck, 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS NY 11952 CODE REQUIREMENTS 5. INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6. SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT PROJECT#: ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJ.PHASE: PERMIT BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE DATE: B TIME OF CONSTRUCTION B DESIGNED BY: ED 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, CHECKED BY: GS SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30 - SCALE: NTS WIND LOADS - COMPONENTS AND CLADDING (C&C) AND FOR CONFORMANCE WITH THE TITLE: 2020 RESIDENTIAL CODE OF NEW YORK STATE. THIS CERTIFICATION DOES NOT APPLY TO STRUCTURAL ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION A 8.THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A SHEET: 9. REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA S-02 1 2 3 4 5 6 7 8 9 10 11 12 13 i— 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER NOTES: S o L w R 4589 AUSTIN BLVD ISLAND PARK,NY 11558 1. NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR TEL: 516-837-3459 ELECTRIC SYSTEM) FAX: 516-706-1789 2. GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING 'SPLIT-BOLT CONNECTOR' 3. IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE THEINFORMATIONOF OPOWE DISCLOSED HEREINISTHE SOLE H H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED DERIVED FROM MAIN SERVICE PANEL REPRODUCTION OR DISTRIBUTION THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT HOUT PRIOR SPECIFIC WRITTEN PERMISSION 4. CONNECT UTILITY SIDE TO PANEL LUGS PROFESSIONAL SEAL 5. USE TAP RULES FOR SIZING TAP CONDUCTORS (NEC 240.21) 6. SIZE GEC AND EGC AS PER NEC 250.66, NEC 250.122 RESPECTIVELY 7. PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 250.64(B), NEC 250.120(C) G ARRAY 1 8. FINAL SCHEMATIC SPECIFIC TO THIS INSTALLATION AVAILABLE UPON REQUEST SOF NEK/ INVERTER(S) AC �Q'� DAY D. S DISCONNECT co 0 F � v r 0 '0.a X84531 PROFESS\��P E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR Danielle&Jacob Waltz PROJECT LOCATION: 575 Theresa Drive, Mattituck, C MAIN MAIN c NY 11952 SERVICE TAP O 1 BREAKER SERVICE O PANEL ENCLOSURE PANELETTE PANEL PROJECT#: UTILITY UTILITY PROD.PHASE: PERMIT METER METER DATE: B B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: SE-01 1 2 3 4 5 6 7 8 9 10 11 12 13