HomeMy WebLinkAbout46400-Z o�osul 1'�lpGy Town of Southold 12/7/2022
a P.O.Box 1179
0
53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43660 Date: 12/7/2022
THIS CERTIFIES that the building ADDITION/ALTERATION
Location of Property: 335 Village Ln., Orient
SCTM#: 473889 See/Block/Lot: 25.-2-4.13
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
11/10/2015 pursuant to which Building Permit No. 46400 dated 6/10/2021
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
alterations and additions, including front enta stoop,rear deck and"as built" sunroom,to existing single family
dwelling as applied for per ZBA#6942 dated 4/21/2016 and ZBA#7576, dated 1/20/2022.
The certificate is issued to Bhattacherjee,Arjun&Clancy,Nora
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 46400 12/6/2022
PLUMBERS CERTIFICATION DATED 7/7/2021 a p Pl bing&4ting
A ho 'ze S ature
SUFE TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
oy • �� SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 46400 Date: 6/10/2021
Permission is hereby granted to:
Kane, Keith
PO BOX 626
Orient, NY 11957
To: Construct interior alterations to an existing single family as applied for only.
Replaces BP#40265
72TA-3 2022=AMEND-Permit:-'to include legalize as-built conversion of screen porch to
habitable, conditioned space as per plans provided, with ZBA# 7576 and HPC
approvals.
Additional certification may be required.
At premises located at:
335 Village Ln., Orient
SCTM #473889
Sec/Block/Lot# 25.-2-4.13
Pursuant to application dated 6/10/2021 and approved by the Building Inspector.
To expire on 12/10/2022:
Fees:
PERMIT RENEWAL $1,215.00
AMEND NIENTTTO PERMIT _$257..6
Total: $1,472.60
Building Inspector
TOWN OF SOUTHOLD
�oo�°S�FfQ a BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
y . SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 46400 Date: 6/10/2021
Permission is hereby granted to:
Kane, Keith
PO BOX 626
Orient, NY 11957
To: Construct interior alterations to an existing single family as applied for only.
Replaces BP#40265
At premises located at:
335 Village Ln., Orient
SCTM #473889
Sec/Block/Lot# 25.-2-4.13
Pursuant to application dated 6/10/2021 and approved by the Building Inspector.
To expire on 12/10/2022.
Fees:
PERMIT RENEWAL $1,215.00
Total: $1,215.00
Inspector
YuFFat� TOWN OF SOUTHOLD
BUILDING DEPARTMENT
y TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 40265 Date: 11/13/2015
Permission is hereby granted to:
Kiener, Sean
249 W 29th St Apt 7S
New York, NY 10001
To: construct interior alterations to an existing single family as applied for only.
At premises located at:
335 Village Ln, Orient
SCTM # 473889
Sec/Block/Lot# 25.-2-4.13
Pursuant to application dated 11/10/2015 and approved by the Building Inspector.
To expire on 5/14/2017.
Fees:
SINGLE FAMILY DWELLING- ON OR ALTERATION $1,000.00
-ALTERAT DWELLING $50.00
Total: $1,050.00
Building nspec or
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing" land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
- -3.--Copy of Certificate of Occupancy $:25- - -
4. Updated Certificate of Occupancy- $50.00
.5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00
Date. f�
New Construction: Old or Pre-existing Building: (check one)
Location of Property: 313" L4(I J 1f= 00�z- /
House No. Street Hamlet
Owner or Owners of Property:
Suffolk County Tax Map No 1000, Section Block Lot
Subdivision Filed Map. Lot:
Permit No. �7�i S Date of Permit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval: /
Request for: ' Temporary Certificate Final Certificate: tl (check one)
Fee Submitted: $ 1 r
Applica gnature
pF SO(/ly�l
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 �Q sean.devlinO-town.southold.ny.us
Southold,NY 11971-0959 COUN'f`I,��
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Arjun Bhattacherjee
Address: 335 Village Ln city:Orient st: NY zip: 11957
Building Permit#: 46400 Section: 25 Block: 2 Lot: 4.13
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: Promaster Electric License No: 59226ME
SITE DETAILS
Office Use Only
Residential X Indoor Basement Service
Commerical Outdoor 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt 6 Ceiling Fixtures 1 Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors
Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch UC Lights Dryer Recpt Emergency StrobeHeat Detectors
Disconnect Switches 4'LED Exit Fixtures Sump Pump 11
Other Equipment: Mini Split
Notes: " AS BUILT NO VISUAL DEFECTS " REAR PORCH
Inspector Signature: Date:_ December 6, 2022
S.Devlin-Cert Electrical Compliance Form
OF 50�T�o� .
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 11790
Southold,NY 11971-0959
BUILDING DEPARTMENT j r
TOWN OF SOUTHOLD '-' ' JUL - 7 2021
Z
CERTIFICATION z
4
Date:
DO I
Building Permit No. v O
Owner.
(Please print)
Plumber: I'-I All lo
(Please print)
i
I certify that the solder used in the water supply system contains less than 2/10 of 1%
'
lead.
1
lumbers Signature)
Sworn to before me this
day of TU JAI , 20Z
Taylor Kurlowicz
Notary Public,State of New York
No.01 KU6404083,Suffolk County
Commission Expires,February 10,20.L44
�� s
Notary Public, .�C� roYJ County
i
1
i
ji
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION- 1 ST [ ] ROUGH PLUMBING
[ ] FOUNDATION 2ND [ ] INSULATION
[ ]
FRAMING / STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ 'J ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ I] CAULKING
REMARKS:
�U
DATE -' INSPECTOR
OF SOGIyo�
# # TOWN.-OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] I ULATION/CAULKING
[ ' ] FRAMING /STRAPPING [ FINAL
[ ] FIREPLACE &--CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT'CONSTRUCTION [" ] :FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
_REMARKS: @AWA.6 ��'/'"1'wit
VIVt'P atd.levu cwd,_lfoo�
/tv (3
4 A�2
ovv/ ).f
DATE INSPECTOR
SOUI,���
# # TOWN OF SOUTHOLD BUILDING DEPT.
courm, 631-765-1802
ANSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] F NDATION 2ND [ ] I SULATION/CAULKING
[ FRAMING / TRAPPI G [
[ ] FIREPLACE & CHIMNEY [ ]. FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
RE RKS:
DATE -1 '?Y INSPECTOR
0FSoUTyo� H �� �� VIP --
# TOWN OF SOUTHOLD BUILDING D T.
`ycourmN�' 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION ] PRE C/O [ ] RENTAL
REMARKS: �'��t.�CIL
DATE l SPECTOR
OP SOGIyOIo 1 YJ V J�SJ / ��l• `i, �/
* # TOWN OF SOUTHOLD BUIL NG D T.
631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL
REMARKS: _ 12 ar G•%
DATE INSPECTOR '
1
1
I
%sI
�•S•.�.i i iii i• „_ ___ _ ._ - -
JUL — 9 2021
P17. TDI Terlrr.
`r<
..1'
f _ -�
�� ��-�„„
!_ ..�..
�_ --
�"--�.�_
!}7;1
��_
"HY]FECT
MARK,SCHWARTZ&ASSOCIATES 28495AIain Road• PO Bo.x 933 1933
...............................
631.734.41851
March 31,2091
Southold Town Building Department
54375 Main.Road
Southold,New York, 11971
Re: Kane.Residence Additions&Alterations
.335 Village Lane:
Orient,Nein York
SQTM#1000=25-024.13
Permit#40265
To whom it may!concern,
I have been onsite during the cons.t.tu6tioh phase-And the foundation,framing,strapping,tough
plumbing/pressure test and caulking/insulation have-been completed and meet or exceed.NYS:code
requirements..
Please call this:office with any questions you may have.
Sincerely,
V
J
Mark Schwartz
AIA
i
r
r !
•
STATE BNE ROY Cb. Dr,
rd IF JOT TW4
MSS' . irM �.� ►
I Now.
- _ - - - ---
1. . .. �,►f+ + _ _:%a!�! mac ! Eli�_
' ; , , .
1111,11
EWE quirk
i
wif 11 id
mwal
joy° rpm; TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 5437.5 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 https:Hwww.southoldtowmny.t?ov_
Date Received
APPLICATION FOR BUILDING PERMIT, a
DISAPPROK.
For Office Use Only
Ye.a 3•a-1 AUG 1 1 2021
PERMIT NO. Building Inspector.
RUIL
AApplications and forms must be filled out in their entirety.incomplete D TG DEPT.
pp Y P TO, �j
OF,+r3$JT
applications will not be accepted. Where the Applicant is not the owner,.an z�JI�IA
Owner's AuthorizatidR form(Page 2)shall be completed.
Date: 7Z ZI
Z0V
OWNER(S)OF,P'ROPERTY;
Name: <�6l T1-1 /M A4 E SCTM# 1000- 2 —4,I3
Project Address: VIZZA45AE0R1E .V 11957
Phone#: 7— 6 _ 13F7 Email: C-17.H / Cd
Mailing Address: d O ZD ® f
CONTACT PERSON:
Name: /Cl 1<2 CL/
Mailing Address: d 5-1 O4
Phone#: 51
: / y ®_ Email: ?��Ck 1e—Q
DESIGN'PROF,ESSIONAL INFORMATION:
Name: ARIK sC ;
Z A14
Mailing Address: Q 8 o -3 v C 06 U16 N
�..
Phone#: 6 371 9-dm1Email: T c°1-
CONTRACTOR INFORMATION:
Name: N
Mailing Address:
Phone#: Email:
DESCRIPTION OF PROPOSEDL CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
Other [kG.SdL1:9!6 A7J?C� �SiS��d�l�Rl,��L�'f90CY 6`'�9 $
Will the lot be re-graded? Dyes VNo Will excess fill be removed from premises? ❑Yes KNo
1
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? _Yes XNo IF YES,PROVIDE A COPY.
�ek BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of 5outhoic,Suffolk,County,New York and other applicable laws,Ordinances orRegulatRms,for the construction of buildings,
escribed.The applicant agrees to comply with all applicable laws,ordinances,building code,
additions,alterations or for removal or demolition as herein d
housing code and regulations and to admit authorized inspectors an premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210AS of the New Ycrk State Penal Law. 1
Application Submitted By(print name): A1/Cy,4F4 ARS 4 Cl omuthorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF )
CL being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the A G-_*--
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
0 I day of 2024 _
-J
Notary Pu is WTLLIAM C.GOGGY 4S
NOTARY PUBLIC,STATE OF :WYORK
Registration No,4963689
PROPERTY OWNER AUTHORIZATION suffolkCounty
(Where the applicant is not the owner)
Commission Expires Marc 12,
--residing at_-4eQ
do hereby authorize _ AU ,Q ls/1�/Q�',�_to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
( ;9�6 -/
F
3 za
Iner's-Signatu Date
KAAAEF
Print Owner's Name
2
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD,NY 11971 4 sets of Building Plans
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502 / Survey
SoutholdTown.NorthFork.net PERMIT NO`S o �i Check
Septic Form
N.Y.S.D.E.C.
Trustees
C.O.Application
Flood Permit
Examined 120 Single&Separate
j' Storm-Water Assessment Form
Contact:
Approved 120((( Mail to: 2+ X
Disapproved a/c
Phone:
ExF i.�-io FO `
i� 1 I Building Vector
mt NOV 0 2015
PPLICATION FOR BUILDING PERMIT
L ----
'TF PT.
TOV:N 0�Sr!LT',•')LD ,Date CC
, 20
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced'within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant or name,if a corporation)
(Mailing address of applicant)
State whether applicant is owner, lessee, a ent, architect, en meer, general contractor, electrician, plumber or builder
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will he ne:
335 V I (,L14 co U_ 1 OR I E
House Number Street ,a j4,: „ ,,;v;Harnlet
County Tax Map No. 1000 Section 2 Bl'0'k;' ' ' d=`:;�Z_! Lot 4 ��
.. -. i�' •-•'t- . .. ...CE's
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed,�nstruction:
a. Existing use and occupancy d�
b. Intended use and occupancy
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
11
7. Dimensions ofexistingstructurds, if 4ront Rear Depth
Height Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories .
8. Dimensions of entire new construction: Front Rear Depth
Height Nu ber of Stories
U4ve,
9. Size of lot: Front Rear Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated 1�:� 6
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NOk
13. Will lot be re-graded? YES NOYWill excess fill be removed from premises? YES_K NO
14.Names of Owner of premises 41r, Address Phone No. /� ��O �SI✓�� 7
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY QUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES N07�V
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
.SS. /X ,
COUNTY OG G ,Ake K j t
&ing duly sworn, deposes and says that(s)he is the applicant
(Name of individua signing contract)above na ed,
(S)He is the 4&6���
(Contractor,Agent,'Cofp6rate O facer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn t before me thi /
)°T)7!: , day of 20�
CONNIE D.BUNCH
Nota Pu lac ,State of Ne Si ture f Applicant
rY No.01BU6185050 g pp
Quallfi®d In Suffolk County
Commission Expires April 14,2-
i
- i
i
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following;before applying?
TOWN HALL " ' ' ! Board of Health
SOUTHOLD, NY 1197.1 - -
4-s
ets,bf Building Plans ' !
TEL: (631) 765-1802 Planning Board approval
FAX: (631) 765-9502Survey''
SoutholdTown.NorthFork.net PERMIT NO. Check
Septic•Form
N.Y.S.D.E.0:• ' I
Trustees
C.O.Application I
Flood Permit
Examined I ,20 Single&.Separate !
Storm-Water Assessment,Form
Contact:
Approved i ,20 Mailto• _HkM i z
Disapproved a/c
, �3 �Phone:
Expiration ,20
r ; ' ' /'Build'ngln ector- V._ }+
iI,l r APPLICA'T'ION.-FOR,BUILDIN.G PERIVIIT" ' MAP&OA
llil'I _ ���(- ---- --- .._ . - • -ill - . .- . . _r j . Date.... . .�i ®'>'• �; , 20
bINBTRUCTIONS--=" I:
a. This application MUST-be—,complete-ly:fiIledlin by`fy",pewrifef'or'iii.irik'and-submitted.to the Building Inspector with 4
sets of plans, accurate plot plan to scale, Fee accordin ito schedule.
b. Plot plan_showtnglocation-ofloFin`d—ofbuildings.on-premises;;relationshito.adjoining•premises.or public.streets or
areas, and waterways,
c. The work covered by this applicationanayinot.be commenced;l efore:issuance of-Building Permit.
d. Upon approval of this application,the Building'Ins'pector will issue a Budding Permit to the applicant! Such a permit
shall be kept on the premises-available-for inspection.throughout-the�work. �
e.No building shall be occupied o'r`.used in wlfole or in'part for any purpose what'so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building per.infi•shall expire if the world.suthorizec h'as_raot commenced within 12 months after the date of
issuance or has not been completed.within 18•months-from such.dateIf no zoning amendments or other regulations affecting the
property acted ih thd•iriferim,the Building Inspect" ay authorize; in writing,the extension.of the;permit for an
have been en
addition six months. Thereafter, a new permit shall'be required.
APPLICATION IS HEREBY•MADE:to.thG��luildiiig;L0eparftneri:TO. _the_issuance of a_Building Permit pursuant to the
Building Zone Ordinance of the'Town;of•S;qutliol-d,' uffol�C County;Nev; �or'k; aril other'applicable:Laws,;Ordinances,or
Regulations, for the construction of buildings,-additiojis, or alter. tions`orYfor xemoval ovdemolitionus herein de�cribed. The
applicant agrees to comply with all applicable laws, ordinances,buil'dingtcpde;housing code;and regulations;and to.admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant orname,if a corporation)
�': (Mailing°address of.applicant)'
• i
State whether applicant is owner, lessee, agen , architect, a gineer, general contractor, electrician, plu i ber or builder
Nampremises
.. L of owner of premis .. L :•
• • '(A's"ori the tax roll�or•latestdeed):. . .• , • I
If applicant is a corporation, signature of duly authorized officer
1
(Name and title of corporate officer) !;
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
i
1. Location of land on which proposed work wil be one: i
&44 �j.
House Number Street _; . .si , ... Hamlet
VIT
Lot
County Tax Map No. 1000 Section �' ��
Subdivision_ Filed Map No. Lot
2. State existing use and occupancy of premises and i ende use do cupancy o pro osed construction:
a. Existing use and occupancy
b. Intended use arid occupancy �0'�!1✓� J
3. Nature of work (check which,applicable): New Building Addition Alteration
Repair Removal,. Demolition Other Work o .0 N 1029 C:9L--
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling,.number of dwelling units Number of dwelling units on each-floor
If garage,- nun ber*of cars`
6. If business, com rcial or mike A occugy: ront
y, specify nature and extent of each type of use.
� � -
7. Dimensions of existing structures, if a Rear Depth
Height —Number of Stories
Dimensions of same structure with alterations or additions: Front 'Rear'
_
Depth
Height -,c £a'Number of Stories
8. Dime �,t,n, RK,
NO
struction:.ProntN:.,,, i=t ; .�: _�I i Depth
Heig Number of-Stories
cl9. Size`of lot: Front RearV r Depth
10. Date of Purchase Name.p f Formex,Q)yner ;
11. Zone or use district in which'premises;areaituated:' `.:" .' ,
12. Does proposed construc'tion'iviolaie anyzoning-law;;'ordiriarice'oriegulation,?:,YES NO
13. Will lot be re-graded? YES
, NO Will excess fill''lie remoyed`from,,,premises? YES l NO
(/ A '
14. Names of Owner.of premises .f-' !v: . ,: .:A:ddress: :Pho-ne 139
No..
Name of Architect S Phone.No t� � _�
Name of Contractor :ii;; A`ddre§s-
15 a. Is this property within•100:feet'of a.Atidal wetland:or,&Rd8liwty iii.?w6iland?c`*:YES - 'ANO
* IF YES, SOUTHOLD TOWIJ TRUSTEES &D:E�C ,,PERIv'.TS,MAY'„B:E' � QUIRED::
b. Is this property'within:i300'feet of a'tiddl")Wlarid?.*.:EYES:”
IF YES; D:E.C. PERMITS 1VIAY BE REQLZIRED.`!= °° r
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on p"roperty-is-at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants-and:restrictions with to this property? * YES NO
—k
IF YES, PROVIDE A COPY.
STATE OF NEW YORK) ,: • .: .{ : > ,
SS:
COUNTY OF
d�-' _ ��. b.eing;duly{sw�oin, deposes aind.says that(s)he is the"'.applicant
(Name of mdi idual signing contract) above.named; s }
• .;ll ISA°
(S)He is the
(Contractor,Agent, Cor orate OffAr, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said Work and to make and file this application;
that all statements contained in this application are true to the best'of his knowledge and belief; and thatthe work will be
performed in the manner set forth in the application filed therewith.
Sworn tq before me this
*e day of re-br-u ar 20 lb
TRACEY L.
� DWYER ,
Notary Publi MeTARY LIC,STATE OF Si ture Applicant
NO.01 DW6306900 g pP
QUALIFIED IN SUFFOLK COUNTY
COMMISSION EXPIRES JUNE 30,2jajb
0,111F,11*tJames Garretson,Chairperson Town Hall Annex
Anne Surchin,Vice Chair 54375 Route 25
James Grathwohl PO Box 1179
Donald Feiler Southold,NY 11971
Gary Parker Fax(631)765-9502
Robert Harper Telephone: (631)765-1802
Edward Webb www.southoldtownny.gov
Damon Rallis,Administrative Assistant
Town of Southold
Historic Preservation Commission
RESOLUTION#5.17.16.3
May 17,2016
Rescind Administrative Permit
Authorize and Request the Building Department to Issue a Stop Work Order
RESOLUTION: Authorize and request that the building department to issue a stop work order to
the owners of 335 Village Lane, Orient.
WHEREAS, a building permit was issued for interior alterations at 335 Village Lane, Orient,
and
WHEREAS, the property is a landmark within a historic district, and is therefore under the
jurisdiction of the Southold Town Historic Preservation Commission, and
WHEREAS, the applicant made a permit amendment request to the building department to
allow for window replacements on the facade of the structure, and
WHEREAS, an administrative permit was issued on April 19, 2016 allowing the applicant to
replace the windows"in kind"and a public hearing was scheduled to address
"as built"exterior work, done without the benefit of a required Certificate of
Appropriateness, and
WHEREAS, the applicant failed to appear with amended plans before the Historic
Preservation Commission and it was brought to the attention of the commission
that the windows had been replaced outside of the scope of the administrative
permit, and
WHEREAS, Chapter 170 of the Southold Town Code requires approval from the Historic
Preservation Commission,and is therefore in violation of Southold Town
Code.
NOW THEREFORE BE IT RESOLVED that the Historic Preservation Commission hereby
rescinds the Administrative Permit issued on April 19,2016 (RESOLUTION 4.19.16.1), and
BE IT FURTHER RESOLVED that the Historic Preservation Commission authorizes and
requests that the Southold Town Building Department hereby issues a"stop work order"to the
owners of 335 Village Lane in Orient.
MOVER: Chairman James Garretson
SECONDER: Commissioner Robert Harper
AYES: Unanimous
RESULT: Pass -
Signed: /
Damon Peter Rallis,Administrative Assistant to the Southold Town Historic Preservation
Commission
Date:
our Uni94
e
Mariella Ostroski,Chairperson ���� 7
. Town Hall Annex
Anne Surchin, Vice Chair 2 ®uY�wLG `D 54375 Route 25
Fabiola Santana ::nUMC ® PO Box 1179 lip
Allan Wexler r - r`n,, z Southold,NY 11971
Tara Cubie h ' �ut�A y� Telephone: (631) 765-1802
Jeri Woodhouse
Kim E. Fuentes, Coordinator ARFSERVAf%ON GO email:kimf@southoldtownny.gov
southoldhpc@southoldtownEy.gov
Town of SoutholdHistoric
e 23222 Preservation Commis ioD LSD
RESOLUTION #06.23.2022.02 JUL - 1 2022
Certificate of Appropriateness BgTMDING DEPT.
TO'VN ()F SOUTHOLD
RE: 335 Village Lane, Orient, NY, SCTM# 1000-25-2-4.13
Owner: KEITH AND LYNETTE DANE
RESOLUTION:
WHEREAS, 335 Village Lane, Orient,NY is on the Town of Southold Registry of Historic
Landmarks; and
WHEREAS, as set forth in Chapter 170 of the Town Code(Landmarks Preservation Code) of
the Town of Southold, all proposals for material change/alteration must be
reviewed and granted a Certificate of Appropriateness by the Southold Town
Historic Preservation Commission prior to the issuance of a Building Permit; and
WHEREAS, the applicant submitted"as built"Architectural Plans depicting a conversion of
an approved screened porch to a conditioned habitable space(four season room)
of an existing single family dwelling; and
WHEREAS, the scope of work involves the installation of windows(Anderson Series 400)
and new doors to convert to a four season room as shown on Architectural Plans
prepared by Mark Schwartz,Architect, last revised May 16, 2022; and
WHEREAS, the applicant met with the Commission during public hearings on December 9,
2021 and June 23, 2022, where the applicant submitted final drawings of scope
of work and outlined the project for the Commission.
NOW BE IT RESOLVED,that the Southold Town Historic Preservation Commission
determines that the proposed work meets the criteria for approval under Section
170-8 (A)of the Southold Town Code; and
Page 2
Histfric P-6tervation Commission
KANE
BE IT FURTHER RESOLVED,that the applicant shall submit Two signed and sealed
Architectural Plans to this Commission depicting the windows to be installed on
side elevations as Anderson Windows 400 Series, double hung, (6 over 6)prior
to the issuance of a Certificate of Occupancy by the Building Department; and
BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above
may require further review from the commission; and
BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of
Appropriateness, subject to approvals by all involved agencies.
MOVER: Commissioner Surchin
SECONDER: Commissioner Santana
AYES: Commissioners Ostroski, Surchin, Santana, Wexler, Cubie and Woodhouse. (6-0)
RESULT: Passed
Please note that any deviation from the approved plans referenced above may require further
review from the commission.
n
Signed:
Kim E.Fuentes,Coordinator for the Historic Preservation Commission
Date: June 23,2022
N
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD,N.Y.
NOTICE OF DISAPPROVAL
DATE: February 17, 2016
TO: Mark Schwartz(Kane)
PO Box 933
Cutchogue,NY 11935
Please take notice that your application dated February 11, 2015:
For permit to construct screened porch addition to an existing single-family dwelling and for the
existing accessory garage
Location of property: 335 Village Lane, Orient,NY
County Tax Map No. 1000— Section 25 Block 2 Lot 4.13
Is returned herewith and disapproved on the following grounds:
The proposed screened porch addition on this nonconforming 21,455 square foot lot in the Residential
R-40 District is not permitted pursuant to Article XXIII, Section 280-124,Nonconforming Lots which
states; lots measuring 20,000-39,999 square feet in total size require a minimum side setback of 15
feet.
The proposed construction has a minimum side yard setback of 7.2 feet.
_.-.
In addition, pursuant to Article III, Section 280-15, which states accessory buildings and structures
shall be located in the required rear yard; the existing accessory garage is partially located in the side
nit
Authori ed Sig ture
Note to Applicant: Any change or deviation to the above referenced application, may require
further review by the Southold Town Building Department.
CC:file, Z.B.A.
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD,N.Y.
NOTICE OF DISAPPROVAL
DATE: August 23, 2021
TO: Michael Kimack(Kane)
PO Box 1047
Southold,NY 11971
Please take notice that your application dated July 27, 2021 in conjunction with Building
Permit#46400:
For permit to: legalize the"as built" conversion of the approved screened porch to
conditioned habitable space to an existing single-family dwelling at:
Location of property: 335 Village Lane, Orient,NY
County Tax Map No. 1000 - Section 25 Block 2 Lot 4.13
Is returned herewith and disapproved on the following grounds:
The "as built" construction, on this nonconforming 21,455 sq. ft. lot in the R-40 District,
is not permitted pursuant to Article XXIII Section 280-124, which states lots measuring
between 20,000-39,999 square feet in total size require a minimum side yard setback of
15 feet and a combined side yard setback of 35 feet.
The construction has a minimum side yard setback of 7.2 feet and a combined side yard
setback of 22.2 feet.
Authorized Signature
Note to Applicant: Any change or deviation to the above referenced application may
require further review by the Southold Town Building Department.
CC: file,Z.B.A.
I' ly BOARD MEMBERSSouthold Town Hall
Leslie Kanes Weisman,Chairperson
����� SQUly®l 53095 Main Road-P.O.Box 1179
Southold,NY 11971-0959
Eric Dantest Office Location:
Gerard P.Goehringer G Town Annex/First Floor,Capital One Bank
George Horning �o ® �� 54375 Main Road(at Youngs Avenue)
Kenneth Schneider l'YCQ�NTY,�1 Southold,NY 11971
http://southoldtown.northfork.net
ZONING BOARD OF APPEALS i D
TOWN OF SOUTHOLD
Tel. (631) 765-1809-Fax (631)765-9064 APR 2 5 2016
BUILDING DEPT
7 DINN OF SOUTHOLD
FINDINGS,DELIBERATIONS AND DETERMINATION
MEETING OF APRIL 21,2016
.—� ZBA FILE# 6942
NAME OF APPLICANT: Keith and Lynette Kane
PROPERTY LOCATION: 335 Village Lane, Orient,NY SCTM 1000-25-2-4.13
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this
application and determines that this review falls under the Type II category of the State's List of Actions, without
further steps under SEQRA.
LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the
Minor Actions exempt list and is not subject to review under Chapter 268.
PROPERTY FACTS/DESCRIPTION: The parcel is a non-conforming 21,455 square foot parcel located in an R-
40 zone. The parcel has an irregular shape. There is 60 feet of frontage on Village Lane. The parcel runs 92.36
feet on the North side then turns North and runs 16.16 feet on the West side and then turns and runs an additional
85.57 feet on the North side. The parcel runs 194.38 feet on the East side. The parcel runs 79.43 feet on the South
side, then turns and runs 90.49 feet on the West side and finally turns and runs 95.65 feet on the South side. The
parcel is improved with a 2-story frame house, an in-ground pool, an accessory garage, and a second accessory
structure labeled "building" on the survey, all as shown on a survey by John Metzger L.L.S. dated May 13, 2015
and last updated January 28, 2015.
BASIS OF APPLICATION: Request for Variance(s)from Sections 280-124 and the Building inspector's February
17, 2016 Notice of Disapproval based on an application for building permit to construct screened porch addition to
existing single family dwelling at; 1)less than the code required side yard setback of 15 feet, 2) following proposed
construction existing accessory garage will be located in other than code required rear yard.
RELIEF REQUESTED: The applicant requests a variances to build a screened porch which will result in a side
yard setback of 7.2 feet and which will place the existing accessory garage, currently located in conforming rear
yard, partially in a non-conforming side yard.
FINDINGS OF FACT/REASONS FOR BOARD ACTION:
The Zoning Board of Appeals held a public hearing on this application on April 7,2015 at which time written and
oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property and
surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant .
and makes the following findings:
Page 2 of 3—April 21,2016
ZBA#6942—Kane
SCTM#1000-25-2-4.13
1. Town Law &267-b(3)(b)(1). Grant of the variance(s)will not produce an undesirable change in the character
of the neighborhood or a detriment to nearby properties. The current side yard setback for the south side of the
property is 7.8 feet. The resulting side yard setback created by the covered porch is not a significant increase in the
existing non-conformity. The proposed addition will not be visible from the street and is completely screened from
the adjacent neighbor by an existing 6 foot high stockade fence. The location of the existing garage, which pre-
dates zoning, will not be altered by the porch addition, but it will become partially located in a side yard without
any adverse impacts.
2. Town Law X267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible
for the applicant to pursue, other than area variances. The existing house has a non-conforming side yard setback.
The accessory garage is currently in a conforming rear yard but the proposed porch addition on the back of the
dwelling will subsequently render the garage partially in a side yard.Therefore, variances are required.
3. Town Lave 4267-b(3)(b)(3). The variance(s) granted herein for the side yard setback is mathematically
substantial, representing 52% relief from the code. The variance granted for the partially non-conforming location
for the garage is mathematically substantial representing 100% relief from the code. However, the side yard non-
conformity already exists and the proposed additions and alterations will not change the location of the existing
accessory garage.
4. Town Law 4267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential
community will have an adverse impact on the physical or environmental conditions in the neighborhood. The
applicant must comply with Chapter 236 of the Town's Storm Water Management Code.
5. Town Law V67-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the
Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the
limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase.
6. Town Law §267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the
applicant to enjoy the benefit of a covered porch while preserving and protecting the character of the neighborhood
and the health, safety and welfare of the community.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under
New York Town Law 267-B, motion was offered by Member Dantes, seconded by Member Weisman
(Chairperson), and duly carried,to
GRANT the variance(s) as applied for, and shown on the Architectural plans by Mark Schwartz, Architect and the
survey by John Metzger L.L.S. dated May 13, 2015 and last updated January 28,2015.
Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays
and/or a possible denial by the Building Department of a building permit, and may require a new application and
public hearing before the Zoning Board of Appeals.
Any deviation from the variance(s)granted herein as shown on the architectural drawings, site plan and/or survey
cited above, such as alterations, extensions, or demolitions, are not authorized under this application when
involving nonconformities under the zoning code. This action does not authorize or condone any current or future
use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses,
setbacks and other features as are expressly addressed in this action.
The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does
not increase the degree of nonconformity.
Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the
` Page 3 of 3—April 21,2016
ZBA#6942—Kane
SCTM#1000-25-24.13
Board of Appeals shall become null and void where a Certificate of Occupancy has not been
procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three
(3)years from the date such variance was granted. The Board of Appeals may, upon written
request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one
(1)year terms.
Vote of the Board. Ayes: Members Weisman (Chairperson), Schneider, Dantes, Horning, Goehringer. This
Resolution was duly adopted(5-0).
Ili- �44 h" C'-
Leslie
Kanes Weisman, C airperson
Approved for filing /2 /2016
BOARD'MEMBERS Southold Town Hall'
Leslie Kanes Weisman,Chairperson ,Zf S,1( 53095 Main Rod • P.O. Box 1179
Patricia Acampora
!p )outhold,N' 11971-0959
Eric Dantes , jig Office )Location:
11 Town Anne /First Floor,
Robert Lehnert,Jr.
IQD O 54375 Main Road Youngs.A.
Nicholas Planamento G� '��0 (at g Avenue)
NN9� Southold,NY 11971
R CEIVED
http://,sou.tholdtownny.gov ,
ZONING BOARD OF APPEALSg,��
TOWN OF SOUTHOLD JA 7 2022
Tel.(631) 765.1809 •Fax (631) 765-9064
Southo d 'down Clerk
FINDINGS, DELIBEI2ATI(INS AND DETERMINATION
MEETING 01 JANUARY 20,2012
ZPA.FILE : 75.76
NAME OF APPLICANT: Keith & Lynette Kane:
PROPERTY LOCATION: 335 Village Lane, Orient, NY SCTM--No..1000-25- -4.13
S
)R-.A DETERMINATION;:The Zoning.Board of Appeals has visited the 1propert-�Ainder.consi. e-Ation in this
application ari`d:dotenb nes.th this r.:eview falls under the Type.Il category of the:S.tate's List of A tions, without
:fuiher,steps.under$EQRA;
: S_UFFOLK COL7NTY ADIVLINIS'RATIVE CODE: This app was referred as.required un-is er.the Suffolk.
C.putty:Adiriiriistati�r .Code Sections:A.14-14.to 23 and i:he Suffolk.Coun' De artiste f..Platiri'
dated:-Septerriber':7; 202 t3' . p. nt.4_ .. . tng ssued its reply
:I statiit`gahat th:is.application.:is cusidered a rrtatter for Local det6r).'inatign:'a .there appf,iirs
to: eripaigti"icant county�wde::or inter-.community:impact.: .
:.L ':DET�RlVhINATION:, The relief, permit; or interpretation -reque"steel`iri This a" "lication.is li teal under the
Pp
Miigr.`Aetigns_:ekemptTist and is not subject to.review udder C1iapter 268;
PROPERTY FACTS/DESCRIPTION: The.parcel is a non=con:Forming 21, 455 square,foot,parcel loe ted in an R40
. Qnirig District:The' parcel.has an irregular shape with a frontage of 60 feet`on�Iillagesane, The par. el runs 92,36
feet"ozi the North sidc'theri turns North and runs 16. 16-feet-on the Westside and.tl en.tuim' and runs an additional
85,.57.feet on the"North side: The parcel runs 194:38 feet.on the.Eastside: The.parcel'runs.79.43 .fee on"the South
side .then tussis a..d.furls 90':49-feet on the West side.and-finally turns'and runs.95: d5 feet on the-S uth side:The
parcel is;Jmproved:'with a two-story frame house, an in-ground swimming pool, anacc;ess:ory garage, and a second
accessory structure laUeled.".building" on.the survey, all as shown on.a.survey prepar:,ed:by Jolin:;lVtetz er L,L.S., last
revis;ed,January.28 2016.
BASIS: OF APPLICATION: Request for Variances from. Article XXIII, Section 280=:124; and the Building
Inspector's August 23, .2021 Notice of Disapproval based on an application for a permit to legalize he "as built"
conversion .of the approved screened porch to conditioned habitable space attached to an existing ingle family
dwelling; at 1)'located less than the code minimum required-side yard setback of 15 feet; 2) located less than the code
minimum required combined side yard setback of 35 feet:; located at: 335 Village Lane, Orient, . SCTM No.
1000-25-2-4.13.
Page 2, January 20, 2022
#7576, Kane
SCTM No. 1000-25-2-4.13
RELIEF REQUESTED: The applicant requests variances to "legalize" the "as-built" conversion of the approved
screen porch to conditioned habitable space with a side yard ;setback of 7.2 ft where.a minimum of 15 ft is required,
and a combined side.yard setback of 22:2 ft where a.minimum of 35 ft is required.
ADDITIONALINFORMATION: .As per testimony given during the public hearing, it was rioted hat the setbacks
requested are from the conversion to hab .itable:space and not an.increase in floor.area. The existing structure has the
same setbacks as the previously approved:screen porch approved..in 2016 with ZBA 116942.. The representative
informed the Board-that .the property. :has a new owner and the Board asked that current owners information 'be
submitted. The variance relief is subject to receipt of amended plans (elevations) conformin to comments
by the Town of Southold Historic Preservation Commission. Architectural plans dated J nuary 5,-2022
were received on January,10, 2022
FINDINGS OF FACT/R9ASONS FOR BOARD ACTION:
The Zoning Board of Appeals held a public hearing on this application on January.6, 2022 at which time written
and oral-evidence were presented. Based upon all testimony,.documentation, personal inspection of the properly
and surrounding neighborhood, and other evidence,'the;ironing.Board finds the; following facts to be true and
relevant and makes.the following findings:
1. Town Law 5267-b(3)(b)(1) Grant:of the variances will not produce an undesirable change.in ,he character of
the neighborhood or a detriment to nearby properties, The current side yard setback and combined setbacks are;not
changing due to the conversion to habitaple space; The setbacks were approved in a previous variance #:6942 in
2016 and have not changed since:
2. Town Law 267ib(3)(b).(2). The benefit sought by the applicant cannot be achieved by.some . ethod, feasible
for tlie..applicant to pursue,other than an area variance,. ']'tie original screened porch addition required variance relief
therefore any conversion of that addition to habitable sp;�ce will also require variance relief;
3. Town Law:5267-b.U) )(3) The variances) granted herein are mathematicall substantial re
Y , p esenting 52/0
relief from the side yard setback and.37% relief from the eombine,d side yard seitback. However,.the onstruction:in .
question already exists with previous variance relief,.'Ud the current relief is for conversion to habitable space only,
no increase in the.non-conformity,is proposed.
4. Town Law 8267-b(3)(b)(4) No.evidence has F)eern submitted to suggest: that a variance in t is residential
community will have an adverse impact on the physical or environmental conditions in the rieig borhood.,Tlle
applicant must comply with Chapter 2j36.of the Town's Storm Water Management Code.
5. Town Law $267-b(3)(b)(5) The difficulty has been self created. The applicant purchased w the parcel after the
zoning Code was `iri effect. and it is presumed.that the applicant had actual or constructive knowledge' of the
limitations on the use of the parcel under the Zoning Code in efi:ect prior to or at the time of purchase.
6. ;rown Law 267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the
applicant to enjoy the benefit of conditioned habitable space while preserving and protecting the eh racter of the
neighborhood and the health, safety and welfare of the community.
RESOLUTION OF THE BOARD: In considering all ofth.e above factors and applying the balancing tet under New
York Town Law 267-13,motion was offered by Member Lehnert, seconded by Member Weisman(Chaff-person), and
duly carried, to
I
Page 3,January 20, 2022
#7576, Kane
SCTM No. 1000-25-2-4.13
GR,
,ANT the variances as applied for, and shown on the survey prepared by John T. Metzger, .S., last revised
January 28, 2016(Note: as built structures shown as
.proposed)and architectural plans(61eiiations)p epared by Mark
Schwartz, Architect, last revised January 5, 2022
SUBJECT TO THE FOLL WING CONDIT30l'dS
1. The applicant must apply to the Building Department for a building p6 init for the "as built" '
improvement(s) within 90 days of the date of this decision and submit same to the Office of the Zoning
Board of Appeals, or submit a written request fo:r an extension to the Board of Appeals setti g forth the
reason(s).why the applicant was unable to obtain a building permit in the time allotted.
2. The applicant must obtain a Certificate of Occupancy:from the Building Department for the 'as built"
improvement(s) and submit same to the Office of the Zoning Board of Appeals within 12 in nths of this
decision or submit a written request for an extension to the Board of Appeals setting forth th reason(s)
why the applicant was unable to obtain a Certificate of occupancy in the time allotted.
3. The "as built" improvement(s)may not be used until a Certificate of Occupancy has been obtained.
built habitable addition,
4. The applicant must obtain approval from the Historic Preservation Commission for the extef'or.of the as
5'. The applicant shall submit to the Zoning Board of Appeals proof of current ownership.
This approval shall not be deemed effective until the reiptired conditions have been met.At the dis retion oj'
the.Board of Appeals,failure to comply with the abo.ve.'conditio
void ns may render this deeisiotznull and
That the above conditions be written into the Building liispector's Certificate of Occupancy,.when i sued,
The Beard reserves the right tosubstitute a similar design that is de miniinis in nature. or an
increase.the degree of nonconformity, alteratton that does not
Airy deviation from the survey; site plan andlor architectural drawings cited in,this decision ivlll result in delays
and/or aposstble denial.-by the Building Department of a buildingpermtt;'and ni�zy require anew appl'cation and
public,heaeing before the Zoning Bocird of Appeals.
Any deviation from the variance(s)
cttecl above;such as alterations,.exten lions, ore demoliticrein.as �ns�Nerre n authorized underitecturat.drathNis asp.11ca la a d/or survey
noncgraforrriities under the zonlving
ing o'ode. This action does notauthorize or condonE'any'ourpent orfuture use, pbac.k
or oilier feature of the subject property that"may violate Plxe Zonink,Code, gtlier than such.uses;setbac and other
features.as are expressly addressed in this action. In the event that this is an avproval.subject to conditions, the
approval.shall not be deemed effective until such time that.the foregoing conditians are mel;:.and failure to"co Z
there-kj' will render this approval null and void. pY
Pursuant to Chapter 280-146(B).of the Code of the Town of Southold any,variance grantel by the
Board iof Appeals shall become null and void where a Certificate of Occupancy has not been
procured, and/or a subdivision map has not been. filed with the Suffolk County Clerk, within three
(3) years from the date such variance was granted, The Board of Appeals-may, upon written
request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one
(1) year terms.
Page 4,January 20, 2022
#7576, Kane
SCTM No. 1000-25-2-4.13
IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE COMPLIANCE WITH
THE CODE REQUIRED TIME FRAME DESCRIBED HEREIN.
Vote of the Board: Ayes: Members Weisman (Charpex;>on) Dantes, Acampora, P.lanamen o and Lehnert.
This Resolution was duly adopted (5-0).
an
e. Kanes We's
m . , Chairperson.
A.pPiroved for filing / obi / a a.
BOARD MEMBERS rjF SO�j Southold Town Hall
Leslie Kanes Weisman,Chairperson O�� y0l 53095 Main Road• P.O. Box 1179
O Southold,NY 11971-0959
Patricia Acampora Office Location:
Eric Dantes Town Annex/First Floor,
Robert Lehnert,Jr. • COQ 54375 Main Road(at Youngs Avenue)
Nicholas Planamento Olif'C�OI ,� Southold,NY 11971
http://southoldtownny.gov
ZONING BOARD OF APPEALS v_ D
TOWN OF SOUTHOLD
Tel.(631)765-1809.•Fax(631)765-9064 JUS. 16 2021
JBUILDING DEPT.
July l5,2021
TOTI'N OF 9CiIT l'IIOI,IJ
Mark Schwartz,R.A.
-P.O.Box 933
Cutchogue,NY 11935 rj
Re: De Minimus Request,File#6942
Kane,335 Village Lane,Orient,NY
-.:—=-- --------------------------------_ ---------�CTIyLI�o__1040�3-�3--o�J-�.-.�.�.__`_��..��--------.. ------------
Dear Mr..Schwartz;
We.are in receipt of your correspondence dated July 13,2021 requesting a de minimus approval to convert an
unconditioned screened-in porch addition attached to.a single family dwelling to habitable conditioned space.
.The Board;determination of Apri12--1, 2016 granted the construction of this screened-in porch addition
` reducing the side yard setback to 7.2feet which is less than the code required of 15 feet..
In your fetter you explain that the owners of the premises were advised:by their contractor to install windows
and .convert the porch into habitable conditioned space to be.used as a family room. This decision came.about
because a first floor front room was converted roto a bedroom for ori&bf'their children in what you termed as a
small house.
I reviewed your letter and corresponding file,and have determined that itis the Board's long standing practice,
:that the proposed change of the"screened in"unconditioned porch to conditioned habitable space is not de
minimus.in nature. Should you wish to pursue an approval for the conditioned habitable living area,you will
need variance relief with a new application and a public hearing.
Please contact our office for any additional questions or concerns.
fKq'
es Weis an
Chairperson
cc: Michael Verity,Building Department
BOARD MEMBERS Southold Town Hall
Leslie Kanes Weisman,Chairperson $®U'��'®�® 53095 Main Road• P.O.Box 1179
Southold,NY 11971-0959
Patricia Acampora Office Location:
Eric Dantes Town Annex/First Floor,
Robert Lehnert,Jr. 54375 Main Road(at Youngs Avenue)
Nicholas Planamento ®��'C®U11,� Southold,NY 11971
http://southoldtownny.gov
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD
Tel.(631) 765-1809 •Fax(631) 765-9064
June 16, 2022
Michael Kimack
P.O. Box 1047
Southold,NY 11971
RE: Request for a 90-day Extension
Appeal No. 7576,Kane
335 Village Lane, Orient
SCTM No. 1000-25-2-4.13
Dear Mr. Kimack;
We received your email correspondence, dated June 6, 2022, requesting an extension for your client to
comply with the Zoning Board of Appeal's condition#1 relating to "As Built" improvements described in
the January 20, 2022 decision.
The aforementioned condition required the applicant to apply for a building permit for all "as built"
structures approved by this Board within 90 days.
In your letter you explain that you are waiting for approvals from the Historic Preservation Commission.
During the June 16, 2022 Regular Meeting,the Zoning Board of Appeals granted your request for a 90-day
extension beginning this date and to expire on September 14, 2022.
Feel free to contact our office if you have any further questions or concerns. I will instruct the office to send
a copy of this letter to the Building Department.
Teslie
Dnes Weisman D
Chairperson JUN 2 4 2022
cc: Building Department
BUTLDINIG DEPT.
TOWN OF SOUTHOLD
Y w
BOARD MEMBERS Graz Southold Town Hall
Leslie Kanes Weisman,Chairperson s®N sk, �` 53095 Main Road P.O. Box 1179
ii �� Southold,NY1971-0959
Patricia Acampora 1
w, 11: Office Lo ation:
Eric DantesW; '� "'" `
V,. ti __1%C: Town Annex/First Floor,
Robert Lehnert,Jr. F
®� y4 54375 Main Road (at Youngs Avenue)
Nicholas Planamento �Eq,NT``r, S Southold,N 11971 1dI �ti�
!zzz'-zz,a;c�'
http://southoldtownny.gov
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD
January 25,2022
Tel.(631)765-11809•Fax (631) 765=90644
Mi-.hael Kimack
,P.O. Box 1047
Southold,NY 11971
RE: Appeal No. 7576,Kane
335 Village Lane, Orient
SCTM No. 1000-25-2-4.13
Dear Mr. Kimack;
Transmitted for your records is a copy of the Board's January 20, 2022 Findings, Deliberations ar d
Determination, the original of which was filed with the Town Clerk regarding the above variance
application.
Please be sure to apply for a building permit fOr the "as built"structures within 90 days of ate of the
decision. "
God 9'a a� ,fix/0,41- '
,Before commencing any construction activities, a building permit is necessary. Be sure to submil an
application along with a copy of the attached determination to the Building Department.
;Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted y the
'Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured,
and/or a subdivision map has not been filed wiith the Suffolk County Clerk,within three(3) years
from the date such variance was granted. The!Beard of Appeals may, upon written request prior to
the date of expiration, grant an extension not to exceed three(3) consecutive one (1)year terms.
It is the property owner's responsibility to ensure compliance with the code required time frame
described herein. Failure to comply with requestiing extensions in a timely manner may resu It in the
;denial by the Building Department of a Certificate of Occupancy and may require a new ap lication
for variance relief with public hearing before the Board of Appeals.
If you have any questions, please don't hesitate to contact our office.
Sincerely/:;,
Kim E. Fuentes
-Board Assistant
Encl.
cc: Building Department
r
Scott A. Russell
�� �� STOR IM[\WAT]ER.
SUPERVISOR NIAN AGE MUEN T
SOUTHOLD TOWN HALL-P.O.Box 1179 a
53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of So u th o l d
CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET
( TO BE COMPLETED BY THE APPLICANT )
DOES THIS PROJECT ECT INVO LVIE ANY OF THE FOLLOWING:
Yes No (CHECK ALL THAT APPLY)
❑ A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
❑ B. Excavation or filling involving more than 200 cubic yards of material
within any parcel or any contiguous area.
❑ C. Site preparation on slopes which exceed 10 feet vertical rise to
100 feet of horizontal distance.
❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
❑ E. Site preparation within the one-hundred-year f loodplain as depicted
-- ~- — --on-FIRM-Map of any-watercourse.- - - -
F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
APPLICANT: (Proper y Owner,Design essional,Agent.Contractor,Other) S.C.T.M. #: 1000 Date:
District /� p
NAME: �. T 5, 0?-[O'g 1 l%
Irtmt Section Block Lot
FOR BUILDING DEPARTMENT U. l Cttl_,i�
Contact Information: C�7 �t/ ,
:relepLanr\uinhfi
Reviewed By:
Pate:
Property Address / Location of Construction Work: — — — — — — — — — — — — — — — —
3 f �� I� Approved for processing Building Permit.
�f � p Stormwater Management Control Plan Not Required.
T
Stormwater Management Control Plan is Required.
(Forward to Engineering Department for Review.)
FORM # SMCP-TOS MAY 2014
Scott A. Russell 01 ST01KNIWATEK
SUPERVISOR NIANAG]EIMHENT
SOUTHOLD TOWN HALL-P.O.Box 1179
53095 Main Road-SOUTHOLD,NEW YORK 11971 Town vf So u th o lld
CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET
( TO BE COMPLETED BY THE APPLICANT )
DOES THIS PROJECT INVOLVE LV1E ANY OF THE FOLLOWING-
Yes No (CHECK ALL THAT APPLY)
A. Clearing, grubbing, grading or stripping of land which affects more
than 5,000 square feet of ground surface.
❑ B. Excavation or filling involving more than 200 cubic yards of material
within any parcel or any contiguous area.
❑ C. Site preparation on slopes which exceed 10 feet vertical rise to
100 feet of horizontal distance.
❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area.
❑ E. Site preparation within the one-hundred-year floodplain as depicted
on-FIRM Map-of-any-watercourse.
❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square
feet or more, unless prior approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in-kind replacement of impervious surfaces.
If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name,
Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project.
If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan
and a completed Check List Form to the Building Department with your Building Permit Application.
APPLICANT: (Property Owner,Design ional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date:
o7 ¢ 3
NAME: AlAjex
�t Section Block Lot
73
Contact Information: FOR BUILDING DIS, r-�RTME'NT USE O.NL E
:Telephone Nuinbeti
Reviewed By:
Date:
Property Address / Location of Construction Work: — — — — — — — — — — — — — — — —
33s //L G�� [J/Apprcwed for processing Building Permit.
[ / Storm at
V er Management Control Plan Not Required.
�t4e Z� ❑ Stormwater Management Control Plan is Required
(Forward to Engineering Department for Review.)
FORM # SMCP-TOS MAY 2014
�OSUfFp��CO BUILDING DEPARTMENT- Electrical Inspector
Gy.� TOWN OF SOUTHOLD
o =` Town Hall Annex- 54375 Main Road - PO Box 1179
o _ ae
Southold, New York 11971-0959
4'4 app Telephone (631) 765-1802 - FAX (631).765-9502
rogerr(-Dsoutholdtownny.gov - seandCaD-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 11/7/22
Company Name: Promaster Electric
Electrician's Name: Fausto Lopez
License No.: 59226-ME Elec. email:Promasterelectric@gmail.com
Elec. Phone No: (631) 377-8059 01 request an email copy of Certificate of Compliance
Elec. Address.: 73265 Main Road Greenport NY 11944
JOB SITE INFORMATION (All Information Required)
Name: Keith Kane
Address: 335 Village Lane
Cross Street: Main Road and Orchard St
Phone No.: 917 685 1397
Bldg.Permit#: 46400 email:keithakane@gmail.com
Tax Map District: 1000 Section:25 Block: 2 Lot:4.13
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Wiring for 4 season porch addition - lighting, hvac, and receptacles, as built in 2016.
Square Footage: 297 SF
Circle All That Apply:
Is job ready for inspection?: YES❑ NO ❑Rough In ❑✓ Final
Do you need a Temp Certificate?: ❑ YES R NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
r-1 New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 FJ2 H Frame Pole Work done on Service? DY N
Additional Information:
PAYMENT DUE WITH APPLICATION
��pF SOVIyp
Town Hall Annex Telephone(631)765-1802
54375 Main Road ,ax(631)765'.&J2
P.O.Box 1179 G ZINC@ roger.richertCa own:Soutfio d.nV.us
Southold,NY 11971-0959
BUaDING DEPARTMENT
TOWN OF SOUTHOI D
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: LsoC� fI=rcj Date:
Company Name:
Name: r
License No.: 3
Address: 0 ' 283 filel l
Phone No.: 3 p JB„c C63j
JOBSITE INFORMATION: (*Indicates required information)
*Name: Ih r
n
*Address: r I n
*Cross Street:
*Phone No.: a _ 6g 32
Permit No.: q/i,? 6
Tax-Map District: 1000 Section: Block: Lot:
'BRIEF DESCRIPTION OF WORK (Please Print Clearly) e
\gay d s� c��c� Fl �olr
Please Circle All That--Apply)
Is job ready for inspection: LY5V1 NO <Q22gh In
Final
Do-you need a Temp Certificate: YES/ NO
'emp Information (if-needed)
Service Size: 1 Phase Whase 100 150 200 300 350 400 Other
New Service: Re-connect Underground Number of Meters Change of Service -Overhead
,dditional Information: PAYMENT DUE WITH APPLICATION O7 �9
�-X
?
�cb�j�e
-82-Request for Inspection Form
;1 .a iP y
BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
� ..
Town Hall Annex-54375 Main Road- PO Box 1179
CIO
Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
roaerra-southoldtownny.aov- seand c-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (Ail Information Required) Date: 11/7/22
Company Name: Promaster Electric
Electrician's Name: Fausto Lopez
License No.: 59226-ME Elec. email:Promasterelectric@gmail.com
Elec. Phone No: (631)377-8059 01 request an-email copy of Certificate of Compliance
Elec.Address.: 73265 Main Road Greenport NY 11944
JOE SITE INFORMATION (All Information Required)
Name: Keith Kane
Address: 335 Village Lane
Cross Street: Main Road and Orchard St
Phone No.: 917 685 1397
Bldg.Permit#: 46400 email:keithakane@gmaii.com
Tax Map District: 1000 Section:25 Block: 2 Lot:4.13
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Wiring for 4 season porch addition - lighting, hvac, and receptacles, as built in 2016.
Square Footage: 1297 SF
Circle All That Apply:
Is job ready for inspection?: YES❑NO F]Rough In 0 Final
Do you need a Temp Certificate?: El YES 0 NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter#
❑New Senrice®Fire Reconnect[-]Flood Reconnect OSenrice Reconnect[]Underground QOverhead
#Underground Laterals F 1 FJ2 H Frame 0 Pole Work done on Service? n Y nN
Additional Information:
d �'� PAYMENT DUE WITH APPLICATION t d � � � �0
UV., 1 4 2022
13P � (�o `fDo
B I-iMDI?C,DEPT.
rl"O-WN
SOTUT1aOLD
PERMIT # Address:
Switches l
Outlets I✓ ' I
GFI's
Surface f
Sconces`
H H's
UC Lts
Fans Fridge HW
Exhaust Oven WAD
Smokes
DW Mini lI
Carbon Micro fWerator
Combo Cooktop Transfer
AC AH Hood Service
Amps Have Used
Special:
Comments
BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex-54375 Main Road-PO Box 1179
. . _ Southold, New York 11971-0959
Telephone'(631)765-1802-FAX(631)765-9502
rogerrOlsoutholdtownny.gov seandCa�southoldtownny.gov
` APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN:INFORMATION (All lnformation'Required) Date: 1117/22
Company Name: P'romaster Electric
Electrician's Name: Fausto Lopez
License.No.: 59226-ME Elec.email:Promasterelectdc@gmail.com
Elec. Phone No: (631)377-8059 ✓❑1 request-an email copy of Certificate of Compliance
Elec.Address.: 73265 Main Road Greenport NY 1.1944 -
JOB SITE INFORMATION (All Information Required)
Name: Keith Kane
Address: 335 Village Lane
Cross Street: Main Road and Orchard St
Phone No.: 917 6851397
BIdg.Permit#:46400 ,a9 =: .-,, email:keithakane@gmail.com
Tax Map District: 1000 Section:25 Block: 2 Lot:4.13
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE'FOOTAGE (Please Print Clearly):
Wiring for 4 season porch addition - lighting, hvac, and receptacles, as built in 2016.
Square Footage: 297 SF
Circle All That Apply:
Is job ready for inspection?: 0 YES--0 NO ❑Rough In Final
Do you need a Temp Certificate?: ❑ YES NO Issued On
Temp Information: (All information required)
Service Sizer-11 Ph❑3 Ph Size: A #Meters Old Meter#
F1 New',Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
#Underground Laterals 1 n2 n H Frame F1 Pole Work done on Service? Y N
Additional Information:
REM "a REM 0
® PAYMENT DUE WITH APPLICATION 1 b` n` + CIO
NOV 1 4 2022 "RecA 0 31 � Z
13P*-Lf (o `f00
BUILDWG DEPT.
TOWN OF SOUTHOLD
. i
Town Hall.Annex r, Tele hone 631
X1802
54375 Main Roada Fax(631)734-9502
P.O. Box 1179 y
Southold, NY 11971-0959 tia•
Qf �
BUILDING DEPAR°T`MENT
NOTICE OF. UTILIZATION AF.:?RUSS TYPE CONSTRUCTION, PRE-ENGINEERED
WOOD"CONSTRICTION ANDI,OR-TIMBER CONSTRUCTION.
Date: 0
Owner.
Location of Property: C,
Please take notice that the (cheek 00' --able line):
New residential:structure .
Addition to eAsting;residential structure :
Rehabilitation to.an.,eAstin residential structure .
to be constructed or performed at the!§ub 'ct°pito erty.reference above will utilize
(check applicable line):
Truss type constructi6n1(TT_)'_
Pre-engineered wend. traction PVI )
00,
. Timtjer construction,(TC)
in the followirig location(s) (check applicable line):
Floor framing, indudi%girders and-Team§(F)
_ Roof-flarhing`.(R)'
Floor and roof gaming (FR)
. Signature: ; ... .
Name (pqrsdn.submittip g this fonxi):
t
Capacity(check applicable line):
Owner
Owner representative
TwssResReg15.docx Effective 1/1/2015
i
��S�fFi7L,�00
Town Hall Annex ��� -a G�� Telephone(631-1802
54375 Main Road Fax(631)734-9502
P_O_ Box 1179 CC:)/;P
Southold, NY 11971-0959 w �'
O� ice. •:-.---•:... ��
BUILDING. DEPARTMENT
NOTICE OF UTILIZATION.OF..TRUSS T,�Q.E CQNSTRUCTI.ON, PIKE-EN
WOOD'CONSTRUCTION ANDIOR�rIMBER CONSTRUCTION
Owner: 4
Location of Property: FWT
- Please take notice that the (phedk a jP,6p,
New residential structure
Addition to existing:redden#ial structure ro c# �• �o
Rehabilitation to:an,:bAsting.residential stritcfure "_;,:•
to be constructed or performed at the'stab`` cfi`'ro' a ,ref, rerce above will utilize
r. `.+ .A �
(check applicable line):
construcfaia.(TT '.. ,;.
Trusstype
_.. . _.._
Pre-engineered Woodpanstr.d6 an= PRV
Timber constructidn
in the followirig locations) (check applicable line):
Floor frarning, inciudirig:giiders:agd.faoams(F) ..
Floor and roof-framing (FR)
Signature:
Name (persc^.sub�:nitt:ngth. ;�
s f;;r<<:!):
Capacity (check applicable line):
Owner .
Owner representative
TrussResReg15_docx Effective 1/1/2015
6" DlAMIl TE-R
FtEr(;ECTt1lE RF,i3 ,:: . S ROMAN ALPHANUMERIC .
RANTQNE- DESIGNAT(Ot1.OF'CONST-R_UCTION
(PMSj#RB7 .N: ct �''�.� ,' V PE�BEiS DgON SECTION 602 OF
THE SUILDNG CODE OF NEW
YORK STATE
- - REFLECTIVE
WHITE
1/2aa.STROKE
._..-. - - •:'D�EStG�,�Y �fiI�FOFt`•'S'i`E�UICT�t2Ai-� ..- ----. -•-- . ---- -- ---- _. ----- ----
"i'RUSS CdhfSTRUCT(ON
"F" FLOOR FRAMING,,I�R,CLUDING- -
GIRDERS AND B,EANIIS• ..�-- •'-.
goo
"FR" FJia�OR kl17�10. F'filZAhi(itG
COMPIJANCE WITH 1911VC RR PART...-126. .
COdES dxV(SIdN
.�--o- =inPLC TRUSS lDENflFIGUON SIGN DACU08/L01J
' ` �� R STATE DE ART EN.�` � ST TE
.131VISl0N -0F C0D-E E N FORIC EM E: NT .
``' � AND ADMINISTRATION
pF SOUryol
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 G • Q
Southold,NY 11971-0959 �Q
COUNTV,Nc�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
STOP WORK ORDER
TO: Keith & Lynette Kane
335 Village Lane
Orient, New York 11957
YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK AT:
335 Village Lane, Orient, New York
TAX MAP NUMBER: 1000-25.-2-4.13
Pursuant to Section 280-144-10(B) of the Town of Southold, New York, you are
hereby notified to immediately suspend all construction until this order has been
rescinded.
BASIS OF STOP WORK ORDER:
Construction has gone beyond scope of approved plans.
CONDITIONS UNDER WHICH WORK MAY BE RESUMED:
When approval from Landmark and Building Dept. has been issued for all
changes.
FAILURE TO REMEDY THE CONDITIONS AFORESAID AND TO COMPLY
WITH THE APPLICABLE PROVISIONS AYr=STITUTE AN
OFFENSE PUNISHABLE BY FINE I RISONMEN OR BO H.
DATE: May 20, 2016
a al s
Plans Examiner
IT SHALL BE UNLAWFUL TO REMOVE THIS NOTICE WITHOUT WRITTEN
CONSENT OF THE ISSUING AGENCY.
Horton, LisaMarie
From: Keith Kane <keithakane@gmail.com>
Sent: Thursday, November 17, 2022 11:45 AM
To: Horton, LisaMarie
Subject: Re:46400 Inspection Ticket 11/15/2022
Hi Lisa, we would like a 6 month extension on building permit 46400 at 335 Village Lane, since it expires on
12/10.
Can you confirm?
Sincerely,
Keith Kane
On Thu,Nov 17, 2022 at 11:14 AM Horton, LisaMarie<lisamariehgsoutholdtommU.gov>wrote:
Please see attached building inspection ticket from 11/15/2022
Kind Regards,
L�Sa
L�saMar�e H-ortow
Southold Town Building Department
Office Assistant
631.765.1803 /631.765.9502 (f)
1
I
1qI SURVEY OF PROPERTY
S?' ORIENT
TOWN OF . SO UTHOLD
um
SUFFOLK COUXTY N. Y.
1000-25-02-4.13
SCALE:MAY 0
, 2015
a
Yf
,y MAY 19, 2015 (REVISIONS)
v SA6.0 j 30£
A.
JAN. 28, 2015 (PROP. DECK &'PORCH)
•
��' �0 � � +co ,�,_ � 92.36,�ry��•• � S>?ai¢830b
Qln �� .Er�m �m ,s3 `s; 855 •
�► ,Oo s N ��� 'fiecb
,fie• GARAGE BU/LDlIYG �'�\
2 s71: o
M. HSE � `�' � 14 S•
1 STY. , LOT COVERAGE
fR HSE 2g ,
u r sromE EXISTING 1 681 s .ft
HSE. & COVERED ENTRANCE q
Cava282 s ft.
BU LD NG 444 sq ft.
2407 sq.ft.
^' / 'e• �� V 2407/21,455 = 11.2X
9Sss, as ; pm cv POOL - 720 sq.ft.
EGUFAOff
fE0'X 0' 720/21.455 – 3.4%
GARAGE T \D.vQ' AT COMPLETION OF CONST.
PROP–PORCH &_DECK 599 sq.ft.
'l, �• HSE. GAR & BUILDING 22,4 sq.ft.
RAW 2946/21,455 sq.ft. = 13.7%
CESEAFIED TO:
N D KIENER
ALLISON EISEN yOMpy
TD :BANK, N.A., ISAOAIA77MA
STEWART TITLE INSURANCE COMPANY $�
ry0
h �
AREA 21.455:sQ. Fr. ti •o° :DISAPPROVAL
®r 0,49.25 ACRE •O
cryo
Q= U77UTY POLE N6Ire
•= PIPE
3' LIC. NO, 49618
ANY ALTERATION-.OR ADDITION TO THIS SURVEY IS A VIOLATION PECONIC SURVEYORS,. P.C.
OF. SECTION =72090F THE NEW YORK STATE EDUCATION LAW. ; (631) 765=5.020.FAX (631) 765-1797
EXCEPT-AS PER SECTION 7209-SUBDIVISION 2.• ALL;CER77FICATIONS P.0. BOX 909
HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY-IF 1230. TRAVELER STREET -
SAID MAP OR COPIES.BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR 15—'13
WiOSE SIGNATURE APPEARS HEREON. SOUTHOLD, N. Y. :11971
�.
SURVEY .OF PROPERTY
Me N Sri' ORIENT
TOWN OF - SO UTH'OLD.
SUFFOLK CO UNT�; MY
1000-25-02-4
13
o . p
!— '
. ., SFS F - � SMA Y 3, 2015. .
De
MAY. 19, 2015 (REVISIONS)
SA6�>`3OaEa'' JAN. 28, 2015 (PROP. DECK &'PORCH)
O • 6 4'M
�'�► =ry Flt HSE `� d '4 s• :
r STY , �� LOT COVERAGE
o• FR HSE 2
*a
Mr-S AIE EXISTING
Nsb`y c HSE. �c COVERED ENTRANCE 1681 sq.ft.
`�r0,, Vis• �«� �, Q GARAGE 262 sq:ft
�Y ^3 BUILDING 444 sq!
ib :2407 sq ft.
. � r 9S6s. Q*� /^ . '�• �� ��
2407121,455 = 11.2%
POOL
i u rr Ia.o�r�4ao, 4 Q 720/21.455 = 3.4X
GARAGE AT COMPLE770N OF CONST.
PROP.;PORCH &.DECK 599 sq.ft.
HSE. GAR. & BUILDING 229L sq•
2946/21,455 sq.ft s 13.7X
CER77PIED TO: 4F�,S,� 4,
SEAN D KIENER
ALUSON EISEIV U�ljpy
TD .BANK, N.A., ISAOA/A71MA RFy �2
STEWART 777LE INSURANCE COMPANY
a l/ ovo zgP
(� g\69 p e��e`Nve
e� V "
as i
AREA . 21.455.SQ. RT. ,dry AO _ pat
or 0.49.25 ACRE
0= U77UTY POLE
•= PIPE `�Qb� "�• •
N0. 49618
ANY AL7ERATTON-OR ADDITION TO THIS SURVEY IS A VIOLA77ON PECONIC SURVEYORS, P.C.
OF SEC77ON .7209OF THE NEW YORK STATE EDUCA77ON LAW. - (631) 765-5020 FAX (631) -765-1797
EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ALL.CERT IRCA77ONS ! P.O. BOX 909
HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY-IF. I 1230' 7RAVELER STREET
SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR
-.. .-- - 1 5-139
WHOSE SIGNATURE APPEARS HEREON.
sou THOLD, N Y 1197
Ns i To WN OF SOUTHOLD
'FOLK COUNTY, Al. K
MA Y 2015
JF
pm
-Wmw .
I WA
.14
AREA 2"455 ~=~~ FT
or 0,49.25 ACHE
41,
wg
REVI IONS:
NEW ROOF LINE
E�l 7z
PFOPOSE3 SCREENED-IN PORCH
O O
11-
ROS
REACY
REAED
R DECK
W
Q
PROPOSED REAR ELEVATION O
s�va•er ��jj O
�7 a
❑ . VVz
tra
W-a PROPOSED SCREENED-IN POROH
ENSTNG DOOR
— — — — — — — — — — — TO Be REMOVED
❑ ❑ ❑ ❑ ❑
E%ISTINS STORAGE
AREA TO BE REMOVED
PROPOSED RIGHT SIDE ELEVATION a
2 Sc; Va•.r-o' C
U F
14'-0•PROPOSED SGREENED.IN PORCH NEW ROOF LINE [}
❑ from�8A
81d9 fleeto V cdocuments U
viewed J AI
- 28A
- - - - - - - - - - - - - - - - - - pate
EXISTING STORAGE PROPOSED REAR OEC:
OEAWN:1N IMS
AREA TO 8E REMOVED
_ SCALE AS NOTED
JOB 9:
Scab:V4'_Y-0'
PROPOSED LEFT SIDE ELEVATION
3 SNEET NI1MAEft:
- A3
VISIONS;
>
PATIO ON GRADE
(91P 7668Id v � '��• �I♦/� (�
7 V,u,•� 1 1 C/
4 I
SCREENE4 PORCH -� ��P
zb
r�=�Sce==c3i i
OE%IsfT,0-5 REnAD Ey N
ii
ii
HIGH •--1, a
RAUNG b'• D'1 9'-6'X 3'G'PASS'iHAU
_
__2 6 _
20,-V
BATH
J-17 X 3'•6' 1 15•_7 O goo
�,y�� ppt4 ]1L BP 1 ' x I� O F•1
P\ VOLPKT 76Qi6 � I rx
R (�.+ Cd
DECK q I FO W
�
".035F 6Qt O O
K04 ]e0.100F � }� pp
i Y
EXISTING STOOP �'' T�•1 S O O
TO Be REMOVED
- -- - m
�___________
�__________ __r 15-1'X14'4 I h
HIGHI D3 .wEt e¢ze 9P -F.i
RAIUNG ------ '(IN•Ti; iii �' CHIMNEY -- ---i
DOOR REPL-CE iii 4�' REMOVED
REMOVEb WINDOW 6-0' MMED
D7 PR2 6B _ LOP I RE-FRAME
LAUNDRY WALL
} -
IQ-
RE
- p)2x8 7.ic7XW-2* -
REVISIONS:
2
6 13-0'AS BULT GUi PORCH 6
5-v 11.6 3U 3,
g
=-O'AEYBULT FOU40ATM
4 X 4 pDGTG
(R P CAL)
PA710 ON GRADE
I I T PAIR 3O x G',B'
"� I r-------------------- ---- -1 I N I-/3'$Xd'-O' ENTRY DOORS (?)3'$'X4'{7 h
I I 1 1 I I ANDERGEiJ 2z ArmASEN
I I I I I I R
S "'F au�'ywNb
®u I I 1 I I xtl r. w
I c s �p 2xsRR� s'�7' §❑
I I 1 1 I � m � mt6oc ®16D.c p�
I
I I LL� I I I I
p 3 AS-BUILT SUN PORCH u§i
AREA 14sF s C
I I 1 1 I Ib I a� F 4 yCc
STA OVE — — I I BL_F�p i I ¢ F yy I Cuu��ul m o
s in x o x Q 9 ;b PH
I - - - - - _
TWXI A&WILT
ti
[EEO ri
HUI
AS-BUILT REAR ELEVATION
E�l
ARAM U-aA"LLTPORCH
� z
1EEHI IEEBI
RIGHTSed¢V6 s TO SIDE ELEVATION rL� 0-1
IETT11
lFTTll ® L0..
U-aA5,"LT Pll.
rL-J—1 DRAWN:JMIM
SCALLASNOrED
AS-BUILT LEFT SIDE ELEVATION-BUILT JOBU.
V..T-G
A4
REVISIONS:
C' DES OF
L: & TOWN CODES
co i'l I L:
07D N' S OF
'?� --— AS REQUIRED AN") CONDITION
DATE:
4" AT
,2 4 rj i' FOR THE
CE TE
P 0 U E D C,',
FLUMSING
- CUPAr"CY OR
TRUCTION NIUST ki
0(
�7 Coj!�,?� r"-rr*. C:C.�- C.O.
A L 1. C("%i\;'LTi LIC—1 !A 1.L M El E T THE USE IS UNLAWFUL
STORAGE U`.UTRDIENITS OFIIECODES OF NEW CERTIFICATE
y()PV S-r-f-C. j�!'-,T VVITHOUT
AREA: r.�SPONSIOLE FOR r%
DES:(3N OR CONSTRUCTION ERRORS. OF OCCUPANCY
C Ti!A C a',.."' , '! PLUMBER CERTIFIC.A.'r10,"!
70" �;�e®D
Ofkf LEAD CONTENT BEFORE
PANTRY CE r:'7j,7.'!-,'-'7
BATH
-Y 7,470CCUPANCY
PLUMBING SOLDER USED IN WATER
AREA: Al L PLU��31NG WASTE SUPPLY SYSTEM CANNOT A!�
.p,1LE.4E )NIELL EXCEED 2110 OF I% LEAD.
KITCHEN CO'' Z
151-21 x 14'_01 0
L/ AREA: 21235 9F TAI�,I STOR1,11%Nfr�ER, R01OFF
7-10' IL7 i TER 236
FURSUANT TO CHr'x_
OF THE TOVM, CODE.
7�
LF_ ►4
Con
UTILITY LAUNDRY
7-10'X 16-6
AREA: 130.53 SF: l9
Con
BEDROOM #1
cil 201-21 x 131-11,
AREA: 260.70 SF DINING ROOM
151-21 x 121-10,
AREA: 104.e3 SF
SHELF CHASE
SHELF
z
22'-4' 7-9'
BATH
7-9*X 7-6
AREA: 59.44 SF •"j
BEDROOM #2
14-31 x 111-11
LIVING ROOM AREA: 151.90 SF Z
:22'-4'X 14'-3'
A
AREA: 307.60 9F
nl
GLO
>
L
CLO
0-0 C-4
m 10
10
0
AREA: C1' u
0 t�z�
& cn
t
00% .21
0
a)
0 ;4
BEDROOM #3 E
1,4!-3'X 12-6'
.SITTING ROOM AREA: 171.11 SF
151-21 x 121-91
L
AREA: 174.78 9F
FOYER
AREA:
Ou
N
EXISTING FIRST FLOOR PLAN EXISTING SECOND FLOOR PLAN
01
s
Scale: 1/4' =l'-O'
INC
tF
V DRAWN: JM MS
4, SCALE: AS NOTED
JOB
SHEET NUMBER.
Al
REVISIONS
-----------------
20'-8"
----------------20 —8 1 Go _REMO\,E l 01
EX.WALL ' '
1 , , I
REPLACE EXISTING GIRDER AND POSTS
'------- ---------------------------------' CLOSE OFF WALL ; ; WITH(3)1-3/4X5-1/2 ML GIRDER AND
' MORTAR AND SECURE ' 1 , , LALLY COLUMN w/24X24X12 CONC.FTG.
; 1 1 I (CENTER COLUMN ON SPAN)
1 .----------------------------------- 1 w/#f5REBARAT
12"OC(1YP.)
�.----- --------------------- ---------------------------
- (3)2X10 ACQ GIRDER (3)2X10 ACQ GIRDER
o o
�'_ --• g'-4„ •-- - g'-4„
10"dia.CONC.PIER
1 w/24"X24"X12" ' ' 'x '
CONC.FTG.AT ' ; ' '� ; /EX2X6 F-I 0,24-OC
-
' C T BELOW GRADE
(3)
EX,5X6' r t
1^
i
I 1 ' 1 1K ' O
' I 1 ' I l
cx
EX. BASEMENT: !25 N
' 10"dia.CONC.PIER 5X6 F1 ; DIRT ' �.O0 '
1 w/24"X24"X12" , , ' 1 1 V' ' /EX.5X6 FJ N �•] m m
CONC.FTG_AT (3)
Lu
1°-�" 9'-4" 3'BELOW GRADE g'-4" �,- a
C
-- -- EX. CRAWL SPACE
o
V
(3)2X10 ACQ GIRDER i (3)2X10 ACQ GIRDER r _____ DIRT
i 1 I 1
x
0
EX.6X6 GIRDER OVER WALL
cc
EX. CRAWL SPACE ' ----------- ----------
DIRT
---- ---DIRT
o Z
_______________ ________________ EX. CRAWL SPACE p
EX. (2)2X6 GIRDER DIRT
---------------------
EX.6X6 GIRDER OVER WALL
LL E"4a ZZ
Q
a
e
z
LL
z
FK 3X7 FI
III I I
111 1 1 Z o
Irl 1 1
111 I I
111 1 i
111 O
111
Irl c� 1 1
ul 0
❑,a
111- 1 1
u l
co
I 1
rn x 1 1
111 CN I I
III
X X. 1 I
III� I 1
111 O
X. El
FOUNDATION PLAN
111 1 1
III 1 1
III I , O
III 1 1
- 11� SCALE: 1/4" = 1'
111 1 I � a
ul 1 I V
x
W
EX. BASEMENT ; ; z
1 111 SLAB ' ' O Q
In I 1 J }
nl
EX_ 3X7 F) ,2R"OC Lu z
„ J
d 1 I F—
ul Q
Z
111 1 , UJ
O
In
111 I I
cy)
III
I 1
ACCESS "' ' ' ACCESS M
EX. CRAWL SPACE
DIRT DRAWN: MH/MS
` '�; p� SCALE: 1/4"=1'-0"
JOB#:
November 10,2015
SHEET NUMBER:
A- I
j
REVISIONS
\VIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS
USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION.FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY.
4"MAX.
4"MAX.
♦I I#-
4"DIA.MAXIMUM
4"DIA.MAXIMUM
POST
GIRDER/HEADER
0
�zo
0 e
POST/COLUMN s
e
Z 12"x12"x12'
CONCRETE FOOTING
m
DECK POST FTG.CONNECTION
DECK/PORCH At IN . LOCATION USP NUMBER DESCRIPTION APPLICATION
4X4 POST PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH FOOTING
STAIR RAILING POST-TO-GIRDER/HEADECONNECTION 6X6 POST U66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH FOOTING N
UlE MIN.(2)1/2"
DIA.GALV.BOLTS WITH WASHERS AND NUTS PA
1-1/2"SPACE
MINIMUM Nj s a M m
r7 x
� C
HANDRAILS
GIRDER V w y 00
T__11-I
POST V a ,z IV
GIRDER/HEADE2 0 n
0
•: U ,=i
40 . POST/COLUMN
BALUSTERS RIM/DECKJOISTu CONCRETE PIER ••+•• o
OPEN BALUSTER ATTACHED TO WALL
HANDRAIL CONNECTION
ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH POST-TO-DECK CONNECTION
OF THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS HEADER/GIRDER-TO-POST CONNECTION
SHALL NOT BE LESS THAN 1-1/4"NOR MORE THAN 2"IN LOCATION USP NUMBER DESCRIPTION APPLICATION
CROSS SECTIONAL DIMENSION,OR THE SHAPE SHALL USE MIN.(2)1/2"DIA.GALV.BOLTS WITH WASHERS AND NUTS (2)BEAMS PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH PIER
PROVIDE AN EQUIVALENT GRIPPING SURFACE GIRDER/HEADER TO POST/COLUMN CONNECTION (3)BEAMS PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH PIER
C/1
FLASHING TUCKED UNDER O E^
TOP PIECE OF SIDING AND ^i C)
LAPPED OVER FIRST CONTIN. z
GIRDER/HEADER PIECE OF SIDING BELOW Q
2-1/2"DIA.LAG BOLTS W/WASHERS W
CONNECTED TO BLDG.@32"OC UNDISTURBED SOIL C�
LAY PLASTIC BASE DIRECTLY ON
STAT R TREAD o 0-4POST/COLUMN o UNDISTURBED SOIL(ORGANICS REMOVED) Q
RIM BOARD o° LEVEL BASE
FIT CONSTRUCTION TUBE AND PLUMB W/•�
STRINGER FLOOR FRAMING BRACE TUBE
2x JOISTS FILL AS PER MANUFACTURES'INSTRUCTIONS
z
BLOCKING FOR
JOIST HANGER _III-III III III III III III III III-11
POST-TO-GIRDER/HEADER CONNECTION LAG BOLTS % p
O
LOCATION USP NUMBER DESCRIPTION APPLICATION RIM JOIST/BD. e
C�0
4x4 SOLID COLUMN PBS44/PBSE44/KC44 POST CAP ANCHOR APPLY TO EACH COLUMN
6x6 SOLID COLUMN PBS66/PBSE66/KC66 POST CAP ANCHOR APPLY TO EACH COLUMN
STRINGER TO DECK/PORCH CONNECTION HOLLOW COLUMN SIMPSON STRRI/2 H.C. ANCHOR APPLY TO EACH COLUMN DISTURBED/POOR SOIL
DECK/PORCH LEDGER CONNECTION rf�1
LAY 4.6'LAYER OF CRUSHED STONE OR 0
GRAVEL
LEVEL AND COMPACT BY HAND U
LAY PLASTIC BASE ON COMPACTED GRAVEL
LEVEL BASE
FIT CONSTRUCTION TUBE AND PLUMB
"' BRACETUBE
FILL AS PER MANUFACTURES'INSTRUCTIONS
STRINGER c I=11 �I-
e16"Oc III III III III III=III III=III III=II
(2)THRU- WOOD JOIST JOIST
BOLTS
(ANCHOR
44 POST -1 s
. dia. GIRDER/HEADER CONC.PIER FOOTING w
o' PIER 16"TREAD BIGFOOT SYSTEMS FOOTING FORM
` WOOD JOIST
GIRDER/HEADER IN ACCORDANCE WITH SECTION 104.11 OF N.Y.S.RESIDENTIAL CODE THIS DESIGN
o° COMPLIES WITH THE INTENT OF THE CODE AND THE MATERIAL OFFERED IS W
GRADE CSLAB
(AS REQ.) AT LEAST THE EQUIVALENT IN DURABILITY AND EFFECTIVENESS OF THAT z
IAS R 'd'°t" o
`" a PRESCRIBED IN THE CODE.
p FLUSH JOISTS WITH HEADER/GIRDER THE DIVISION OF CODE ENFORCEMENT AND ADMINISTRATIONS FINDS THIS PRODUCT J }
8"dia. '%h a DECK PIER ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH ACCEPTABLE FOR USE IN N.Y.S.BASED UPON ICBO EVALUATION SERVICE REPORT W Z
CONC. ° '�', PER PLANSPLICED JOISTS OVER HFADER/GIRDER ER-5495 AND SUBJECT TO THE CONDITIONS THEREIN.
3'-O" i, d „, THE PROPER STEEL CONNECTOR.
y� PIER c' 4 IF ABLE,SET FIR JOISTS APROX.1/4"HIGHER THAN LVL HEADERS LOCATION 1U5P NUMBER I DESCRIPTION APPLICATION ,T�
" d' TO ALLOW FOR SHRINKAGE. JOIST TO GIRDER/HEADER RTIO TYDOWN ANCHOR CONNECT TO EACH JOIST W J W
:sv o 4
C� a�
LL0 O
`'M/
M
HANDRAIL NOTES: DECK& PORCH NOTES:
NAILING SCHEDULE
All required handrails shall be of one of the following types 1).Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber.
or provided equivalent graspability. All fasteners,hangers and anchors to be galvinized or stainless steel. JOINT DESCRIPTION NAIL NAIL NOTES
QTY. SPACING ,,�r }
1).Type I.Handrails with circular cross section shalt have an ).Girders for deck joists to be bolted or anchored to each port or pier with washers and nuts JOIST TO: PER TOE ,a0r
YP SILL,TOP PLATE OR GIRDER 4-Sd COMMO 101ST NAIL
;s"•"° � � " o
outside diameter of at least 1-1/4 inches and not greater Girders on concrete piers shall be anchored with proper steel connectors anchored
into concrete with a minimum 1/2"dia x 7"log anchor bolt with washes and nu . CLIMATIC&GEOGRAPHIC DESIGN CRITERIA BRIDGING
than 2 inches.If the handrail is not anular it shall have a h iinnrnuts,
2-Sd COMMO EACH TOE (,�
i ension of at least 4 inches and not realer
TO JOIST END NAIL l i
perimeter dimension g 3).Posts supporting girders shall be anchored to a 12"x12"x12"thick concrete footing. S OWN WIND SEISMIC FROST WINTER DEPLAICESHIELD
PP g g g FLOOD BLOCKING EACH TOE
than 6-ion inches with a maximum cross section of SNOW SPEED DESIGN WEATHERIN LINE TERMITE DECAY DESIGN UNDERLAYMEN
Use a minimum 1/2"dia x 7"long anchor bolt with washer and nuts.Footings Shall HAZARDS 2-Sd COMMO (eJ 7
dimension of 2-1/4 inches. LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED TO JOIST END NAIL
be 4 ft.below grade. jr DRAWN: MH/MS
BLOCKING TO: EACH TOE tp �,
MODERATE SLIGHT TO 3-16d COMMO
2).Type 11-Handrails with a perimeter greater than 6-1/4 4.Deck joists to have blockin at 8'0 o.c.. 45 LBS. 120 B SEVERE 3 FT. Il NONE - SILL OR TOP PLATE BLOCK NAIL "`-^' Is+ a/ SCALE: 1/4"=1'-0"
inches shall provide graspable finger recess area on both ) / g TO HEAVY MODERATE t
P S P g LEDGER STRIP EACH FACE
sides of the profile.The finger recess shall begin with a 3-16d COMMO f �u^ro,:• (✓ ]Q$4:
P g g 5).A minimum of 10 inch flashing shall be installed between the building and ledger. TO BEAM JOIST NAIL
distance of 3/4 inch measured vertically from the tallest Ledger to be fastened to building with 1/2"dia.bolts with washers and nuts �
JOIST ON LEDGER PER TOE November 1Q 2015
portion of the profile and achieve a depth of at least 5/16 at 16"a.c. 3-8d COMMO *,
inch within 7/8 inch below the widest portion of the TO BEAM JOIST NAIL A wt; ry rg(� �i t�' SHEET NUMBER:
profile.The required depth shall continue for at least 3/8 6).Concrete piers shall be a minimum 6"above grade. BAND JOIST 3-16d COMMO PER END " a� e V2J`i
inch to a level that is not less than 1-3/4 inches below the TO JOIST JOIST NAIL - �F O F Ad�`r
tallest portion of the profile.The minimum width of the 7).All joists to be supported with hangers and anchors.Each Joist shall also be anchored TO
JOIST TO: PER -•--
to girder(s). 2-16d COMMO TOE NAIL
handrail above the recess shall be 1-1/4 inches to a g ()• SILL OR TOP PLATE FOOT
maximum of 2-3/4 inches.Edges shall have a minimum 8).Use Simpson hangers and anchors with 2-MAX tripple protective coating or equal
radius of 0.01 inches. for any contact with ACQ.
REVISIONS:
ZONE R-40
M,41N FRONT YARD SETBACK 50'-O"
ST REScheck Software Version 4.6.2
BEET REAR YARD SETBACK 50'-0"
o°
SIDE YARD MIN 15'-0" Compliance Certificate
SIDE YARDS TOTAL 35'-0"
LOT AREA 21,434.00
BUILDINGS
EProject Kane Residence
EXISTING HOUSE 1603.00
Energy Code: 2010 New York Energy Conservation
EXISTING GARAGE 290.00 Location: Suffolk County, New York
EXISTING STORAGE BARN 458.00 Construction Type: Single-family
� EXISTING POOL 859.00
Project Type: Alteration
S Climate Zone: 4 (5750 HDD)
76° O �
'^ 7 3O E TOTAL 3210.00
Permit Date:
Permit Number:
/ - EXISTING REAR °� . S 72°
STOOP TO BE �y ^C9 r ��-- 48 3�„
����, E PROPOSED SCREENED PORCH 322.00 Construction Site: Owner/Agent: Designer/Contractor:
REMOVED
335 Village lane
�Q% Orient, NY 11957
DECKS
/ FRONT STOOP TOB O U '��''�._ PROPOSED REAR DECK 272.00
REPLACED IN KIND p EXISTING .57
EXISTING ���- TOTAL DECKS 272.00
GARAGE STORAG 7 Com
�-- � pliance: 0.3%Better Than Code Maximum UA: 303 Your UA: 302
EXISTIN / TOTAL LOT COVERAGE 3482.00 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. T^
mM/ It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
S 2-5N �;,�' PERCENTAGE OF LOT 16.2
0)/ O;O FRAME / PROPOSED
OCCUPANCY Envelope Assemblies Q
01 �p0 DWELLING REAR DECK / ^�
ry/ NT /EXISTING EXISTING REAR
f ADDITION TO BE / a o o h•�••1
� / 1 -
STY SO, ° o o a � . . ._•. -
N_, \, FRAME � REMOVED // O„R / °Q oo po o v ° 01
Ceiling 1: Flat Ceiling or Scissor Truss 1,603 30.0 0.0 0.035 56
66 O
D�WELLING / SF / o 0 o M--�
PROPOSED % re9C� �" Q o a4°o o Wall 1:Wood Frame,16"D.C. 2,248 13.0 0.0 0.082 163
\• �� SCREENED-IN �� as O Q, o o 000°o Window 1:Vinyl/Fibeglass Frame:Double Pane with Low-E 228 0.320 73
BILCO DOORS '\, PORCH o 0 0
2% Q o Door 1: Glass 33 0.310 10
TO REMAIN `\• �j ADDITION
V I/ o 0 0 Qo Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other W O
T / calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Ener
m% o o \ P PP P P 9 9 9Y
EXISTING SIDE \.,\, �' Q Q / 0 / t j \ .a o I\ / Conservation Construction Code requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in
STOOP TO BE ti� �' the REScheck Inspection Checklist. �1 N
REMOVED Q0
_-4 aQ ✓/h Name-Title Signature Date
/
11
\ V1, ( '1.0 Oct,oQ°
O°Q �°o - -
oo
T PLAN / - --- - -- ---= -
4/ / /moi -_ _ = !� - \ ` La,; "`
PLO - ` � - �� �11 � � Project Title: Kane Residence Report date: 06/06/16
_ W
1 Scale. 1'_20'-O" � ,/ ,\ TI y � /
/ � r, _ \VJ\\ Data filename: C:\PROJECTS\MKS Architect\MKS_1015_022_Kane\Scans\Kane.rck Page 1 of 1
/ � 'I v.�\\ I/ / _ �' iii {, I. 4=• � � �
s�G
ILIw
/ _0
/
o a-
43 v 2
KANE RESIDENCE
GENERAL CONSTRUCTION NOTES: CODE REFERENCES: LIST OF DRAWINGS
1.All work shall conform to the requirements of the New York Tl GENERAL NOTES, CODE REFERENCES, ENERGY CALCULATIONIS o
CODE ANALYSIS ENERGY NOTES FOUNDATION SYSTEMS: Shall conform with Code sections and TAbles R401.4 8401.4.1
ASPHALT ROOF SHINGLE NOTES State Building Code; all work shall also conform to the Al EXISTING PLAN � ELEVATIONS -,
8402.2, 8404.1 AND 8408.1 THRU 408.3 N � �
OCCUPANCY: Residential Single Family Detached 1. Calculations are valid u to 5999 de degree da s. requirements of any other Godes and authorities having A2 PROPOSED FOUNDATION, PLUMBING RISER$ SCHEDULES m o
p 9 Y 1. Asphalt roof shingles shall have self-sealing strips or shall be m v c,
jurisdiction.The Contractor shall obtain and arrange for all A3 PROPOSED FIRST$ SECOND FLOOR PLANS v
: Refer to 2001 AFPA/WFCM Table 3.2A. x
REFERENCE STANDARDS: interlocking and shall comply with the requirements of ASTM D-225 ANCHOR BOLT SIZE AND SPACING
2. Certified conformance for Zone 11B. or D-3462 required permits, nspecton, certificates and tests. A4 PROPOSED ELEVATIONS aa° rn v
n o
Residential Code of New York State 3. Wood framed floors,walls and
PROTECTION AGAINST DECAY: Refer to Section 8319 A5 PROPOSED SECTIONS O o
Wood Frame Construction Manual AF PA(2001) ceilings shall have an approved 2.All fasteners for asphalt roof shingles shall be galvanized steel, 2.All foundations shall rest on undisturbed soil of 1 T.S.F. bearing A6 NAILING SCHEDULE AND CONNECTOR DETAILS
� �
Climate Zone:115 capacity; contractor shall have the level of acceptable bearing w Ua -
vapor barrier(permeance rating of 1.0 perm) installed on the stainless, aluminum, or copper roofing nails. Fasteners shall be PROTECTION AGAINST TERMITES: Refer to Section 8320 v ,t, °-
Degree Days:5750 "warm in winter" side of thermal insulation. strata verified in the field. o .�
minimum 12 gage shanked with a minimum 3/8" dia. head, and of sufflcaent r, U
length to penetrate through the roofing materials and the sheathing. FLOOR SYSTEM: Shall comply with Chaper 5 and AFPA/WFCM 2001 Section 3.3.
DESIGN LOADS: 4.Windows and sliding doors shall have a max. air infiltration 3.All concrete work shall conform to requirements and
Roof: 20 psf ground snow load ratan of 0.3 CFM per s uare foot of window area. Swln in recommendations of AGI-318-99 "Specifications for Structural �
g P q 9 g 3.Asphalt roof shingles shall have the mimimum number of fasteners as WALL BRACING SYSTEM: Shall comply with Sections 8602.8, 602.10, R602.10.10, ,n U
Basic Wind Speed:110 mph doors shall have a max. air infiltration rate of O.5 GFM per Concrete for Buildings' (fc'3000 psi);All exposed m T
P required by the manufacturer. R613.2,AND R(513.3door area. d •� cn
Uplift:18.1# slabs, garage slabs, and steps shall be 3500 psi air-e9 ntrained. co CZ -0
Dead Loads: 10 psf
square foot of Reinforcin steel shall conform to ASTM A-615 Grade GO. N Q) I~ a)
4. For normal applications, asphalt roof shingles shall be secured to the WINDOW ANCHORAGE: Shall comply with Section 8613.5 o W
Table 8301.4 5. Skylight shafts shall have a minimum insulation value of R-19. roof with no less than four(4)fasteners per strip shingle or two (2)
4.All framing
Minimum Uniformly Distributed Live Loads members shall be Hem-Fir #1 (Fb =975psi); WINDOW MULLIONS: Shall comply �
per individual shingle. with Section RG13.6
6. Garages-front, sides, doors,interior shall have max. U..40 fasteners provide(2)2x8 header over all wall openings, unless py wi
(in Pounds per Square Foot) .otherwise noted
5.Asphalt strip shingles shall have a minimum of six(6)fasteners per EXTERIOR WALL COVERING: Shall comply with Section 8702.1, 8703.1, 8703.4 Refer to
Use Live Loads 7.All fireplaces hall be provided with a damper for outside shingle where the eave is 20 feet or higher above grade or where the 5. Micro-lam girders (ML) shall be laminated veneer lumber with Table R703.4 for weather-resistant Siding Attachment and Minimum Thickness. Refer to [�
Iq-
combustion air 150-200 CFM. All flues shall have tight seated base wind speed is 120 mph or greater. Table R703.5.2 for Wood Shakes or Shingles.
Exterior Balconies GO damper with a max. air leakage of 20 CFM. All fireplaces E-2,000,000 PSI. Fb =2,800 P51, as manufactured by W
TRUS-JOIST MCMILLAN. r l F__4
Decks 40 shall have tight-fitting non-combustible doors. FOAM SIDING BACKER BOARD: Shall comply with 8314.2.5 v �
Passenger Vehicle Garages 50 6. Double frame around all openings, under parallel walls and U
8. The Contractor shall submit the design, size and type of 800E/CEILING CONSTRUCTION: Shall comply with 8801.4 and AFPANVFCM 2001 Refe-
Attic without storage 10 under bathtubs. Provide Simpson hanger connections at all O
9 mechanical systems which will be used, in sufficient detail, as to Rafter Span Tables R802.5.1(1) and (2). M
Attic with storage 20 required by the Building Department. flush structural load bearing conditions. U-)
ROOF ASSEMBLIES: Shall comply with Section 8902, R903 and R904.
Rooms other than sleeping rooms 40 9•All thermostas shall be adjustable from 55 degrees to 7.All concrete block shall conform to ASTM C90; Mortar shall be
Sleeping Rooms 30 85 degrees Farenheat. type M ROOF SLOPE: Shall comply with Section 8905.2.2 H
Stairs 4.0 8.All steel work shall conform to the requirements of the AISC Q
10.All ducts and pipes shall be insulated as required by code. ASPHALT SHINGLES: Shall be secured to the roof with not less than (4)fasteners per strip
Guards and handrails 200 "Specifications for Design, Fabrication and Erection of
shingle or (2)fasteners per individual shingle (8905.2.6)
11. HVAC Contractor shall verify heat loss calculations. Structural Steel for Buildings". Steel shall conform to
DEFLECTION LIMITS: ASTM GRADE 36. U
Rafters with no finished ceiling attached: L/180 INTERIOR FINISHES AND MATERIALS: Shall conform to the fire spread and smoke-density cn
Floors: L/360 12.All cellar and/or basement doors shall be insulated. requirements of Section 8315.
9.All electrical work shall conform to local NEC and Underwriters
13. The Architect certifies that to the best of his knowledge, Laboratory requirements. INSULATION AND VAPOR BARRIERS: Shall be fire rated per Section 8316.
Belief, and professional judgement that the plans are in
compliance with the Energy Conservation Construction Code 10. Pre-fabricated fireplaces and flues shall be UL approved. GYPSUM BOARD: Shall conform to Section R702.3.
of New York State. (July 3, 2002)
11. Install smoke detectors and carbon monoxide detectors in MAINTAIN MINIMUM CLEARANCES TO THE BATHROOM FIXTURES: Refer to Section
accordance with all state and local code requirements. 8307
12. The Contractor shall verify all existing conditions before X,
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA STAIR LANDING: Shall comply with section 8311.5.4 c al �'�"' ,
starting construction and shall notify the Architect of any ,•^`'��•,� � ���•
ambiguities or discrepancies before proceeding with STAIRWAY: Shall comply with Section 8311.5 n ���,
ICE SHEILD '= DRAWN: JM/MS
WINTER AIR the work. If any questions arise before or during construction
GROUND WIND SEISMIC SUBJECT TO D,gM,gGE BY HANDRAILS: Shall comply with Section 9311.5.6
UNDERLAY- FLOOD as to the intent or details of the drawings, the contractor + SCALE: AS NOTED
SNOW SPEED IN DESIGN DESIGN FREEZING ' fir' =b «.�,
FR05T LINE MENT HAZARDS shall call the architect Mark Schwartz, at(631)734-4185 for .m., - r JOB#:
INDEX �. .,..,, ,7
LOAD MPH) CATEGORY WEATHERING DEPTH TERMITE DECAY TEMP. REQUIRED clarification and/or instructions. If the contractor fails to Q.•.,�.
follow the above procedure, he shall assume all responsibility � � �' - O SHEET NUMBER:
MOD. TO SLIGHT TO for the consequences of his actions and/or decisions.
20 P517 120 "G" SEVERE 11° YES AE 500
HEAVY MODERATE 13. The owner shall arrange for supervision of the construction A 1
work to ensure compliance with the contract documents.
REVISIONS:
Porch Fdn 6 8/16
00 in"
v-
7f x 10 J 3) 2 77(5T' ' (37-2
F _
_ �_ E_ __ _ _
J—(3) 2 X 10 I --� �AGQI GIRDER --L — I
rw >Y ( I wl 6'
ID w l w I 12"X 12"CONC DI
lac D I D I PIER ON 24"X 24" of
X 12" PIER Lccp1qoo
Q OJTV b 0I FOUNDATION )
(TYPICAL IN 3 ,I p
LOCATIONS) `I' 4
8„ 8" Ix � ' � ' xl 4" THRU VENT
IN x x1 NI
LINE OF DECKI^ ^I ^I dM
STEPS ABOVE 4 X 4 ACQ POST � m m
ON 120 X 42" P.G. j �C 2 v
FOOTING (TYP 4 6 00 �,�
LOCATIONS) ��� - - - - - - - - �_- - - - - _� - - - - - __ - - - ° 2" — 12•' 2„ P..� 7:�
11
-- — -- -- -- -- -- -- -- 1.. �+
– �2S 2 X 8 AGQ GIRDER - - - - - - - - - - - - - - - - - - - - - - - - - - -�
2" 12 2„ O U
I � 2 X 10 AGQ LEDGER I I
BOARD BOLTED TO I I I LAV.
I I HOUSE WITH %"SIJ BOLTS I I W.G. O�
LINE OF DECK ABOVE p I @ 16"O.C. (STAGGERED) ( EXISTING BASEMENT
U I I I ACCESS TO REMAIN ^
I 2"
� N
Q I REMOVE $ REPLACE I REMOVE REPLACE
EXISTING EXISTING I 4
N@ ( I 2X8 FJ I 2X8FJ
_– (2) 2 X 8–AGQ GIRDER – -- I @16"O.G. I @16"O.C.
cn
-F
O
2 X 8 ACQ LEDGER I { 12E,
,
EXISTI�JG BASEMENT
BOARD BOLTED TO I I I I 2 LAV. 2 I I 2 I KITCH.
�Q HOUSE WITH 5/g'0 BOLTS I � { 1 _� L,A ,
@ 16 O.C. (STAGGERED) I I I I I W.G. I— I W.IWO
a
J ISHO ER
4" 2�� L_ —1 2 4I' 2 1st FLOOR
_ - I - - - - -
I I I I F.A.I.
I I I
HOU5E TRAP — X
I „ I TO SEPTIC SYSTEM C.O. w
x u I I 4" X.H.C.I. DRAIN LINE Z
I " d
EXISTING BASEMENT I I
{ { � @j I P PLUMBING RISER DIAGRAM
6 I I Scale: NT5 ^� �
I I -
I- - - - - - - - - - - - - - - - - - - - -�
I I
I I I I
{ I I
i I I I
o
I I I
XLocu
v
I {
J,—.)
4
{ EXISTING ACCESS jc�
EXISTING BASEMENT I TO BASEMENT ,n V
THRU BILCO DOORS v
I I N ow �
I I �
{ WINDOW SCHEDULE
I I I
WINDOW TAG WINDOW SIZE DESCRIPTION MANUFACTURER MFG # 50. FT. GLASS U-VAL VENTILATION CLEAR OPENING REMARKS QUANTITY
or 114 W1 2'_95/8"X 4'_1%4' DOUBLE HUNG ANDERSEN 28310 7.90 0.32 4.39 4.39 4
{ EXISTING I I W2 21-43/a" DOUBLE HUNG ANDERSEN AW251 0.32
I I � EM14
FULL 3 X 6 FJ I 2-4/a X 2'[-43/,5" 1 W
@ 24"O.G. 0. I i W3 2'-9%"X 3'-5%4" DOUBLE HUNG ANDERSEN 2832 6.30 0.32 3.54 6.30 3
5 DOUBLE HUNG ANDERSEN 2032 4.50 0.32 2.62 2.61 2 U
W4 2'-1/8. .X 5-5/4" O
I
W5 2-15/8 X 4-gy4" DOUBLE HUNG ANDERSEN 2046 6.80 0.32 3.88 3.88 2
{ i W6 3-55/3'X 4'-9Y4" DOUBLE HUNG ANDERSEN 3446 12.10 0.32 6.61 6.61 2 ,�
I L I DOOR SCHEDULE �
I
L — — — — — — — — — — — — — — — — — — — — — DOOR TAG DOOR SIZE DESCRIPTION MANUFACTURER MFG # SQ. FT. GLASS U-VAL CLEAR OPENING REMARKS QUANTITY u
D1 PR 2'-ro"X 6'-8" STANDARD PANEL DOORS 2
D2 PR 2'-r6"X 6'-8" EXTERIOR FRENCH DOORS ANDERSEN FWH5068 16.64 0.31 12.98 INSULATED 2
FOUNDATION PLAN D3 3'-0" 6
X '-8" EXTERIOR DOOR INSULATED WITH HALF LITE 1
1
Scale:1/4"-1'-O" D4 2'-6"X 6'-8" POCKET DOOR
STANDARD PANEL DOOR 2
D5 2'-811'X 61-8" EXTERIOR DOOR INSULATED WITH HALF LITE 1
D6 PR 2'-6"X 6'-8" SCREEN DOOR
D7 PR 2'-6"X 61-8" PR POCKET DOORS STANDARD PANEL DOORS
D8 2'-6"X 6'-8" STANDARD DOOR ,�
�. DRAWN: JM!MS
D9 PR 3'-0"X 6'-8" PR. POCKET DOORS STANDARD PANEL DOO,99ff -` s SCALE: AS NOTED
JOB#:
Di0 2'-8"X 6'$" POCKET DOOR STANDARD PANEL DO ?S 2
D11 2'-4'X 6'-8" STANDARD PANEL DOOR -
� Lh SHEET NUMBER:
i.,�. A2
REVISIONS:
PAIR OF SCREEN DOORS
4 X 4 POSTS
PATIO ON GRADE (TYPICAL)
SCREEN PANEL D6 PR 2668 SCREEN PANEL
w w
a
z
O m w
h
l 2X8RR I 2X8RR
@ 16" O.C. @ 16" O.G.
O O
SCREENED PORCH o
oe
x 2'-O" � 7
AREA: 272 SF PROVIDE
HATCHFOR B
Z I ACCESS TO z
4
C Q -�__
REVISIONS:
Porch Fdn 6/8/16
roll
NEW ROOF LINE
�3'+PRQP�SEQREaR-SGREEN I ORGH - - - - - - - - - - - - - - - - - - - - --
In
' a i a ���✓ "TRIM
i BOARD
u�
trxt I ADDED ELECTRIC FOR
y
NEW LIGHT FIXTURE O
,x. yy , �� PROPOSED REPLACED EXISTING DOORWITH NEW
- - - - - - - - - - - - REAR DECK LE — INSULATED EX ER OR DOOR
r -- - h - - -- - I GRADE
GRADE I
PROPOSED FRONT ELEVATION BLUESTONE STOOP
0 PROPOSED REAR ELEVATION Scale:1/4" =,'-O" 7-9" O
Scale: 114!' =I'-C"
O
W �
Wr l
�T� CCl3
EXISTING DOOR
TO BE REMOVED 14'-0" PROPOSED 5CREENED-IN PORCH
— — — — — — — — — — —
oj
11 LJ
dt X"
L] L1
L-Li
------- -------
- - -- -
— —
Y'•
o
GRADE N
6-2"± rn a; u
m o
PROPOSED o m ti 1 °u'
SLATE STOOP EXISTING STORAGE
PROPOSED RIGHT SIDE ELEVATION
2 AREA TO BE REMOVED o ;� w
Scale: 1/4" =1'-0" '6 � u
o
Jo-,
M
Ln U a;
n a\
N O W
i � Cly
14'-0"PROPOSEDSCREENED-IN PORCH — H
EXISTING WINDOWS REMOVED U
U)
N
L±
" EXISTING STEPS REMOVED
GRADE
PROPOSED REAR DECK 1-Y
ya Ma
Y.^ i..
Ir
DRAWN: JM/MS
_ PROPOSED LEFT SIDE ELEVATION �, SCALE: AS NOTED
3 5cale:l/4"=1'-O" !� '�_ .� '- } � �� JOB#:
alv4ra� ihf mi iv"
y' SHEET NUMBER:
REVISIONS:
Porch Fdn 6/8/16
I li
L 7
L — NEW ROOF LINE
— — — — — — — — — — — — — — 14'-O" PROPOSED SCREENED-IN PORCH �j
— — EXISTING STORAGE
O
— --- --- -- AREA TO BE REMOVED M--�
SCREEN PANELS 1"X 1"ACQ BALUSTERS O
LAUNDRY AREA —
9,:`.X sy TOP BOTTOM RAIL lF—�
EXISTING KITCHEN I 4 X 4 POSTS `y : \ '< — F--�
GUTTED AND TO BE `
PROPOSED Y v
REPLACED NEW
<. W
REAR DECK
ow '� I m = �' O �
Z
Q
2 x 10 ACQ -
- - - -- - - - RIM JOIST
x ` CONTINUOUS 2 X 10 ACQ FJ @ 16" O.C. 2 X 8 ACQ LEDGER BOARD W
(3)2 X 10 ACQ GIRD R � BOLTED TO HOUSE WITH 5/g"(d �.,,�
REMOVE AND — — -- GRADE BOLTS @ 16"O.G.
REPLACE EXISTING GRADE (STAGGERED)
2 X 8 FJ @ 16" O.C. STEPS TO
EXISTING BASEMENT 2'-O" 12'-O" GRADE � 5/q." DECKING
EXISTING FOUNDATION WALLS 0 2 X 8 AGQ DECK JOISTS @ 16" O.G.
CANT 2 X 10 ACQ LEDGER BOARD EXISTING STEPS REMOVED
BOLTED TO HOUSE WITH 51a"O
BOLTS @ 16" O.G.
(STAGGERED) 1'-O' (2) 2 X 8 ACQ GIRDER
PROPOSED REAR DECK 4 X 4 ACQ POST WITH AB44
SIMPSON POST CONNECTOR
SECTION
SE�14
ION '.4' . 1/4
1/4" .1'-O"
=1'-O"
Q � �
F-1
C
235 # FIBERGLASS ROOF SHINGLES as
15# FELT
1/2" CDX PLYWOOD SHEATHING W i�
2 X 10 RIDGE ►�
CONTINUOUS RIDGE VENT to
2 X 8 ROOF RAFTERS @ 16" O.C. M O
SIMPSON H3 FRAMING ANCHORS @ 16 O.C.
2 X 4 COLLAR TIES @ 48" O.C.
1 X 6 FASCIA BOARD
VENTED SOFFITS (CONTINUOUS)
- GUTTERS $ LEADERS TO GRADE (TYP.)
m N 0
rn m o
fA M O
I L � NEW ROOF LINE >01 �
6„ 6' - - - - - - - - — — — — — --
1:2"
12"
EXISTING REAR
ADDITION
++ S
REMOVED ROOF FRAMING ROOF FRAMING rn U m
EXISTING DOOR f — 51MPSON G520 CONNECTOR SIMP50N GS20
AND WINDOWS _ _ DOUBLE TOP PLATE OR(2) H2 AT ROOF DOUBLE TOP PLATE CONNECTOR `� o W
REMOVED — I OR(2) H2 AT ROOF
SCREEN PANEL
I I
3/4" PLYWOOD SUBFLOORING — PROPOSED(PORCH
2 X 10 FLOOR JOISTS @ 16 O.G. FINISHED FLOOR TO _ - PROPOSED CRIPPLE STUDS CRIPPLE STUDS
w J TRIPLE JOIST BE FLUSH WITH REAR DECK
O w Q UNDER POSTS HOUSE FINISHED -
Z SIMPSON ST 2215 CONNECTOR SIMPSON W
2 X 10 RIM JOIST(CONTINUOUS) s
(TYPICAL) FLOOR
— — — — — HEADER HEADER MSTG28 U
— — — — HEADER STUDS NOTE: HEADER STUDS CONNECTOR U
x — — — UPLIFT CONNECTION IS REQUIRED AT O
— — — r;, — — — — EACH END OF HEADER AND AT BOTTOM
GRADE 12"X 12' GONC PIER ON OF HEADER STUDS IN ADDITION TO
° 24"X 24"X 24" PIER
' (3) 2 X 10 GIRDER • • FOUNDATION MAX CONNECTORS AT WALL STUDS AND AT 4'-O"70 12'-0" �
EXISTING CELLAR SIDING TO MATCH TOP AND BOTTOM OF CRIPPLES
10'-4" 10'-4" 15 # FELT
ACCESS REMOVED 1'-2 1-2
1/2" CDX PLYWOOD SHEATHING FULL LENGTH FULL LENGTH
SECTION S2 X 4 STUDS @ 10" O.C. WALL STUDS WALL STUDS
B NO UPLI SIMPSON ST2215 CONNECTOR SIMPSON cjj
Scale: 1/4"o l'-O" NNE OR
(2) 2 X 4 TOP PLATE QUIR MSTC28
W. X 4 SOLE PLATE CONNECTOR
HEADER TIE DOWN DETAILS
DRAWN: JM/MS
r r>••..;: ; ,' �, SCALE: AS NOTED
I` l
} � JOB#:
SHEET NUMBER:
or
A5
REVISIONS:
Front Stoop 5/12/16
NAILING NOTES Front Stoop 5/16/16
NAILING SCHEDULE (EXPOSURE "B")
Y NUMBER OF NUMBER OF 1. NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6" ON CENTER AT THE PANEL
JOINT DESCRIPTION COMMON NAILS BOX NAILS NAIL SPACING EDGE. IF WALL SHEATHING IS NAILED 3" ON CENTER AT THE PANEL EDGE TO OBTAIN HIGHER
SHEAR CAPACITIES, NAILING REQUIREMENTS FOR STRUCTURAL MEMBERS SHALL BE DOUBLED,
ROOF FRAMING OR ALTERNATE CONNECTORS, SUCH AS SHEAR PLATES, SHALL BE USED TO MAINTAIN THE LOAD
PATH.
RAFTER TO TOP PLATE (TOE-NAILED) 3 -8d 3 - 10d PER RAFTER 2. WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER
CEILING JOIST TO TOP PLATE (TOE-NAILED) 3 -ad 3 - 10d PER JOIST OF NAILS SHALL BE PERMITTED TO BE REDUCED TO 1 - trod PER FOOT.
CEILING JOIST TO PARALLEL RAFTER (FACE-NAILED) 3. CORROSION RESISTANT 11 GAGE ROOFING NAILS AND fro GAGE STAPLES ARE PERMITTED; CHECK OVERFRAMING 2X-4"WIDER THANROOF RAFTERS \ �"'�
RAFTER SLOPE: 3:12 (HEEL JOINT) 22 - 16d 22 - 40d IBC FOR ADDITIONAL REQUIREMENTS. OVER FRAMING RAFTERS
4:12 17- 16d 17- 40d
5:12 14 -16d 14 - 40d EACH LAP 4. ALL QUANTITIES ARE BASED ON 16" OC SPACING FOR RAFTERS, JOISTS AND STUDS. 3/e'0 LAG BOLT @
7:12 10 - 16d 10 - 40d /� EACH ROOF RAFTER
9:12 AND GREATER 8 - 16d 8 - 40d SIMPSON L50 ANGLE °
5. FOR ROOF SHEATHING WITHIN 4 FEET OF TIE PERIMETER EDGE OF THE ROOF, INCLUDING @ EACH OVERFRAMING /
CEILING JOIST LAPS OVER PARTITION (FACE-NAILED) 4 FEET ON EACH SIDE OF THE ROOF PEAK, THE 4 FOOT PERIMETER EDGE ZONE ATTACHMENT RAFTER
RAFTER SLOPE: 3:12 22 -16d 22 - 40d REQUIREMENTS SHALL BE USED.
4:12 17 - 16d 17- 40d MAIN ROOF
5:12 14 - 16d 14 - 40d EACH LAP 6. FOR WALL SHEATHING WITHIN 4 FEET OF THE CORNERS, THE 4 FOOT EDGE ZONES ATTACHMENT ROOF RAFTERS
7:12 10 - 16d 10 - 40d REQUIREMENTS SHALL BE USED.
9:12 AND GREATER 8 -16d 8 - 40dcoo
�-I
COLLAR TIE TO RAFTER (FACE-NAILED) FALSE VALLEY
RAFTER SLOPE: 3:12 7-10d 7- 12d CONTINUOUS RIDGE VENT CONNECTION DETAIL
4:12 6 - 10d 6 -12d
PER TIECONTINUOUS RIDGE VENT TRIPLE STUD
5:12 4 -lad 4 - 12d p�'
1- 2 1:p„ SIMPSON G520 @ 16"O.C. RIDGE TENSION STRAP SIMPASON 6520 STRAP @ 16"O.G.
6:12 AND GREATER 4 - 10d 4 -12dlE5d
(8)8d NAILS EA. SIDE 1' c 2 SIMPSON G520 @ 16" O.G. WRAPPED AROUND DOUBLE 2 X 6 N ILS COMMON
(G)8d NAILS EACH SIDE NAILS @ 6" O.G. FOR
W RIDGE BEAM (SEE PLAN FOR SIZE) O SILL PLATE FULL HEIGHT OF STUD
BLOCKING TO RAFTER (TOE-NAILED) 2 -8d 2 - lad EACH END ROOF RAFTERS (SEE FRAFTER OR SIZE) EE PLAN (2) 2 X 10 ROOF RAFTERS O Q
RIM BOARD TO RAFTER (END-NAILED) 2 - 16d 3 - 16d EACH END PLAN FOR SIZE) (8)8d NAILS s "
(2) /8 t?J THRU-BOLTS
( (2) 2 X 10 SUPPORT
SIMPFOR SKYLIGHTS
WALL FRAMING EACH SID OF SIMPSON LUS210-2 HANGER
EACH SIDE OF RIDGE BEAM (SEE
1 1 EACH RAFTER PLAN FOR SIZE) (4)10d NAILS (2) s/a"0 ANCHOR BOLT SIMPSON "HD5A"
TOP PLATE TO TOP PLATE (FACE-NAILED) 2 -16d 2 - 16d PER FOOT RIDGE DETAIL AT RIDGE TENSION NAILS EACH PLATE @ 3'-0" O.C. (MIN T' (2) 2 X 10 SUPPORT a
EMBEDMENT) FOR SKYLIGHTSO O
TOP PLATES AT INTERSECTIONS (FACE-NAILED) 4 - 16d 5 -16d JOINTS -EACH SIDE CATHEDRAL CEILING STRAP DETAIL s/8"0 THRU-BOLT SIMPSON LUS210-2 O
IN ACCORDANCE WITH 3.2.5.1. 2001 WWF HANGER O E—I
STUD TO STUD (FACE-NAILED) 2 -16d 2 - 16d 24" O.G. ALTERNATE IN LIEU OF COLLAR TIES FOUNDATION WALL / FLOOR
FRAMING DETAIL SKYLIGHT DETAIL
HEADER TO HEADER (FACE-NAILED) 16d 16d 16" OC ALONG EDGES ?
SIMPSON H2 A
TOP OR BOTTOM PLATE TO STUD (END-NAILED) 2 - 16d 2 - 40d PER STUD HURRICANE CLIPS V TRIPLE STUD
@ 16" O.C. SIMPSON "HD5A"
BOTTOM PLATE TO FLOOR:JOIST, BANDJOIST, ENDJO157 OR 2 - 16d 1,2 2 - 16d 1,2 PER FOOT x �\ )`)(nn ) AC4 EACH SIDE
C520 STRAP SIMPSON HD5A
BLOCKING (FACE-NAILED) N
@ lo"O.C. _ Y""o BOL79
F L R FRAMING ,� MO 3"X 3"XY4 ST. PLATE SIMPSON AB44
O O %"0 THREADED ROD POST BASE
51MPSON H2 @ 16" O.C. W
JOIST TO SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4 -8d 4 - 10d PER JOIST s/8°0 THREADED ROD SECOND FLOOR
5HEARWALL HOLDDOWN
BRIDGING TO JOIST (TOE-NAILED) 2 -8d 2 - 10d EACH END RIDGE / TOP PLATE 4 X 4 POST w
CONNECTION DETAILS
CONNECTION DETAIL
BLOCKING TO JOIST (TOE-NAILED) 2 - 8d 2 - 10d EACH END CANTILEVER DETAIL Q
(2)1%4"X 11%8" M.L.
BLOCKING TO SILL OR TOP PLATE (TOE-NAILED) 3 - 16d 4 - 16d EACH BLOCK 2 X 6 WOOD CAP SIMPSON HD2A
2 X 4 TOP RAIL SIMPSON H210 HANGER @ 16" TRIPLE STUD CCS
Y2"0 LAG BOLTS @ 16"O.G. � �
LEDGER STRIP TO BEAM (FACE-NAILED) 3 - 16d 4 -16d EACH JOIST110, !'•'�
TRIPLE STUD (2)16d COMMON NAILS TRIPLE STUD
4 X 4 WOOD POST @ 48" @ G"O.C. FOR FULL Z
JOIST ON LEDGER TO BEAM (TOE-NAILED) 3 -8d 3 - 10d PER JOIST _ HEIGHT OF STUD (2)16d COMMON NAILS @ •'�
2 X 4 BOTTOM RAIL
CANTILEVER HOEDOWN DETAIL %8"0 THRU BOLTS 6" O.C. FOR FULL HEIGHT M O
BAND JOIST TO JOIST (END-NAILED) 3 - 16d 4 - 16d PER JOIST DECKING OF STUD
SIMPSON H-3 HURRICANE SIMPSON HD2A lo
s/8"0 THRU-BOLTS
BAND JOIST TO SILL OR TOP PLATE (TOE-NAILED) 2 - 16d 2 - 16d PER FOOT CLIPS @ 16" O.C. F Y2"0 LAG BOLTS @ 16" HOLD DOWN
.. SIMPSON HD2A
y P.T. DECK JOIST
ROOF SHEATHING Y2"0 THRU-BOLT @ 16"O.G. � SIMPSON H-3 HOLD DOWN
DBL DECK JOIST HURRICANE CLIP @ 16" (8)8d NAILS @ 1"*O.C. O
STRUCTURAL PANELS: PANEL INTERMEDIATE 112" AT POST AG4 EACH SIDE
EDGES SUPPORTS AG6 EACH SIDE SIMPSON U210 s s
HANGER @ 16" SIMPSON C520 ° ° /8'0 BOLT X 24" LONG a /a BOLT X 24 LONG
INTERIOR ZONE 5 8d lad 4" 6" 4 X 4 POST STRAP @ 16" O.C. a d° m o ;~
PORCH/RAFTER/GIRDER M v
SIMPSON PB44 POST BASE °
PERIMETER EDGE ZONE s 8d 10d q q CONNECTION DETAIL (8)8d NAILS @ 1"=O.G. p d° a ° x
0
GABLE ENDWALL RAKE WITH LOOKOUT BLOCK 8d 10d 4„ q ° O o
Z v
10
CEILING SHEATH ING I
" "
ct X 10 X Y�'
Q BASE PLATE LOAD PATH / FLOOR FIRST FLOOR FIRST FLOOR '
co t:n
GYPSUM WALLBOARD 5d COOLERS 5d COOLERS 7' EDGE /10" FIELD a 411
1"
° a
FRAMING DETAIL SHEARWALL HOLDDOWN 5HEARWALL HOLDDOWN u
u'j co
WALL SHEATHING (4)Y4"0 X 12" LONG °
2'-0"X 2'-0"X 1'-O" N E
PORCH/DECK/JOIST ANCHOR BOLTS FOOTING (TYP) w
STRUCTURAL PANELS/HARDBOARD PANEL INTERMEDIATE CONNECTION DETAIL
EDGES SUPPORTS FOOTING DETAIL
INTERIOR ZONE 6 8d 10d 6" 6" ■■
4' EDGE ZONE 6 8d 10d 6" 6" l cn
W
H
FIBERBOARD PANELS:
7/16" 6d 3 - 3" EDGE /6" FIELD r , U
25/32" 8d s - 3" EDGE/6" FIELD W
GYPSUM WALLBOARD 5d COOLERS 5d COOLERS 7" EDGE /10" FIELD
PARTICLE BOARD PANELS 8d 8d SEE MANUFACTURER
FLOOR SHEATHING x
U
STRUCTURAL PANELS:
1" OR LESS 8d 10d 6" EDGE /12" FIELD
GREATER THAN 1" 10d 16d 6" EDGE /6" FIELD
DRAWN: JM/MS
SCALE: AS NOTED
JOB#:
SHEET NUMBER:
�, _.N ,
REVISIONS:
5/16/22 Add notes
6/28/22 WindowGrill
M
Ar ZO ED AS NOTE 14
DATE: - 3- A B.P.-ff
o O ° o FIE: �g�
IFY B I:.
BY:
O o P�OT
DING DEPAR MENT A7'
p o O 4°perp 765-1802 9 AM TO 4 PM FOR THE
0 0 ° FOLLOkNING INSPECTIONS:
p o 10p po o p ° 00 1. FOUNDATION . TWO REQUIRED
0 0 O 10 FOR POURED CONCRETE
2.3. iRC�3OSULATIO lRAMING & PLUMBING
10 p o o o o ° p p° 0 4 BE COMPLETE FOR C.O.
FINAL - ION MUST
°o ° o O O p 10 10° p0 0 0 ° 1010 ALL CONSTRUCTION SHALL MEET
° 4o O ° o o THE REQUIREMENTS OF THE N.Y.
° o ° O ° o p ° STATE CONSTRUCTION & ENERGY
CODES. NOT RESPONSIBLE FOR
10 og po p o 0 0 10 DESIGN OR CONSTRUCTION ERRORS
O
o j
°Q poo O o o p 10 10 °
oogp p p 10
°
°°
Jill \ o pp 0° °0
rl �\ p Q 0 O o0 O o \ \
O °
o °
j 10p° 10 O e
\ 0 \ � —
\ \ �p
00 0
/
\ p
\ \\\ •.\ — l 9O ° ° ° ° 0
00
— O
o \
\ b O 000 \ \ \
\ / \
—LL
c�3
i
M--1
I
W
MO
l
0
v
ON m o
n +Uc
E
o
� SCG w
AV cz
cuC, CIO
\
P4 T \
�n u
000
O W
W
W
O
U
x
U
JUN 2 9 2022 �
BUILDING DEr,1:
TOV1111 OF SOUTe i' :,n
`:v1
DRAWN: JM/MS
-kSCALE:AS NOTED
JV fi JOB#:
♦;�• �a f
SHEET NUMBER:
TI
REVISIONS:
23-0"AS BUILT SUN PORCH
a
4 X 4 POSTS
(TYPICAL)
PAIR 5-O"x 6'-8"
2' 10"X 4'-2" 2-10"X 4'-2" ENTRY DOORS 2-10"X 4'-2" 2-10"74'-:22"
GLIDER GLIDER GLIDER GL-BU22 O"
Z ' _
Z X p 2X RR 0_2XBRR a O O
F- Z
AS-BUILT SUN PORCH =
N i9 m 22'-0"x 13'-6"
Q AREA: 297 sF
E�d FF]
m
O Q
E :4ZZ
xo I ox
j
a$W
GRADE , 100 I �
BATH
�
7'-10" X S-6
�REA:---272 S
AREA: 27.4 SF
DECK I Q
-
C:
F =
AS BUILT REAR ELEVATION 00 �
Z �-•+
00
W KITC EN I
°L 15'-2" X 14'-0" I
AREA: 212.38 SF
a I
1-
LAUNDRYQ I
7'-10" X 14'-2" a
AREA: 110.95 SF I
El W � o,
MSTR BEDROOM
20'-2" X 13'-11"
AREA: 255.15 SF DINING ROOM I
�
LLL] 15'-2" X 12'-10" ROOF
AREA ' t
14'-O"AS BUILT PORCH 194.63 SF I OVERHANG W
— — — — — — — — — —
— _-- _- MSTR BATH ABOVE
- _ - --
7'-10"X 8'-10"
— — — — — — — — — — — ---- —— O AREA 691
El FMLLU Lu Il l ii 11 11 l 111 III III II III! It
I Lil 1 ]J I I L===]L--Jl
SLATE PLATFORM o
v
CO - o
x �
GRADEL-r P� u
LIVING ROOM u ,
�
I ( 22'-4" X 14'-3"
AREA: 307.89 SF
2 AS-BUILT RIGHT SIDE ELEVATION
l
Scale:1/4" c 1'-0" — J U
Cn in
kz od'o Yo
N
O W
C-Y
® W
O
14'-0"AS-BUILT PORCH FOYER
6'-10" X 5'-9" N
AREA: 39.3 SF PARLOR P
--- 15,-2 X 12 -8
-- - — — — — AREA: 192.20 SF
U U)
LJI I II _ O WALL KEY
EXISTING WALLS TO REMAIN
WALLS rn ac ncMni icucn
a Yy3 Y
PROPOS ,��' :�„.� C DRAWN: JM/MS
GRADE
• '�r SCALE:AS NOTED
Y
- 7
o
JOB
AS FIRST FLOOR PLAN
- 2 SHEET NUMBER:
m (�� Scale:1/4 .1'-O y t
3
AS BUILT LEFT SIDE ELEVATION
Scale:1/4" .1'-O" Al
1
REVISIONS:
7/8/21 AS-BUILT
1/5/22 DH Window
23-0"AS BUILT SUN PORCH WITH NEW WINDOWS 6"
EXISTING PAINTED WOOD
_ _ H DOORS TO REI-1AIN - INSTALL
ANDERSEN 400 SERIES D/H WINDOWS GRILLES ON INTERIOR AND
WITH SIMULATED DIVIDED LITES-GRILLES EXTERIOR AS SHOWN ON
ON INTERIOR EXTERIOR(TYPICAL) ELEVATION VIEW.
4 X 4 POSTS
(TYPICAL)
S-Bu1LT-PORCH-WITH-NEW--WINDOWS PATIO ON GRADE _ /PA5'-0°x 6'-8°
8310-2 18310-2 ENTRY DOORS 18310-2 18310-2
cv D/H D/H D/H D/H p
- Z
p 2X RR 2X8Z
RR O
z
- -- @ 16" O.G.JjF@ 16" O.G. m z
LLJm w AS-BUILT SUN PORCH _
tz 22'-0"x 13'-s" U
ANDERSEN 400 SERIES D/H WINDOWS j Q in AREA: 297 5F O O
WITH SIMULATED DIVIDED LITES- GRILLES i
O 3 z •�
ON INTERIOR EXTERIOR(TYPICAL) �t
O = = O Ct �+
� O
� a
GRADE 17
N U c
FSI
EXISTING PAINTED WOOD LFLOORS 0 O
DOORS TO REMAIN - INSTALL
GRILLES ON INTERIOR AND 100
BATH TO ALIGN CN
� - J
EXTERIOR AS SHOWN. � - -� 7'-10 X 3 -6 ( �
AREA: 27.4 SF
PRIOP05ED REAR ELEVATION I I � �, o
0 Scale:1/4" .1'-0"
DECK P-�
x -_ - IO
I
REA:_-272 SF = O a a
z
Z —
W O O
m �
w KITC EN
°L 15'-2" X 14'-0" I
AREA: 212.38 SF
LAUNDRY
7'-10" X 14'-2"
( w
LLLJ AREA: 110.95 SF
LjN
14'-0"AS-BUILT PORCH MSTR BEDROOM D c
— — — — WITH NEW WINDOWS 20'-2" X 13'-11" I
AREA: 255.15 SF O DINING ROOM
- - - - - - - - - 15'-2" X 12'-10" I�
ROOF
- -- AREA: 194.63 SF OVERHANG
I ABOVE M
MSTR BATH M O
® ® I 7'-10"x 8'-10"
OAREA: 69.14SF
IJJ
1 L-L-Lil L—=LJ
I' I I ��I I I II III
1111111 lillllllllll ! I III Illllllllllllililll I
- - - - - - - - - - - - - - - - — - - - - o
O m N o
Elm: 3= MT >0, 'P,
SLATE PLATFORM °` .
ANDERSEN 400 SERIESO T 2
D/H WINDOWS � � O
WITH SIMULATED DIVIDED LITES -GRILLES '- x C
ON INTERIOR EXTERIOR (TYPICAL)
PROPOSED RIGHT 51DE ELEVATION 11 ° `.0
2 Scale:1/4".1'-O" J ° u
LIVING ROOM -� �'
22'-4" X 14'-3"
AREA: 307.89 SF d U
ao s~
N O W
C
Z
ANDERSEN 400 SERIES D/H
WINDOWS WITH SIMULATED U
DITERIOR EXTERIOR ES OICAL O
14'-0"AS-BUILT PORCH (TY )
WITH NEW WINDOWS
s -10" x 5'-s" PARLOR �
AREA: 39.3 SF 15'-2" X 12'-8" U
AREA: 192.20 SF
io
t~
O WALL KEYIr
EXISTING WALLS TO REMAIN
DRAWN: JM/MS
WALLS T � 4•�;; ,, 1C � SCALE:AS NOTED
JOB#:
PROPOSE Com '' ;,R�4
SHEET NUMBER:
3 PROPOSED LEFT SIDE ELEVATIONt
PROPOSED FIRST FLOOR PLAN
Scale:1/4"c 1'-O"
[J A
11 11
REVISIONS:
5/16/22 Add notes
6/28/22 WindowGrill
O
O p o 0
0 0 O o 0 O o opo � o
p o 00 po o D ° oo
0 0 0 0 0 0 0 0
o p o 0
o po o a o
0
0
0 p
oogo
p°
°
o
-
°
o p °
p °
O O O p a° °O
\ p a 0 0 0o OIn Tj
° \\
T o
1/ O ° \ —
0 00 0 con
00 00 X
/
0
0
o
I \ I
� MO
� A
� Y
m N �
v
X M
w
CN
00
� v
N O W
t~
L' U
�O
cn
D
JUN `l9 ZU22 x
U U
TOWN OF SOU 4�M1SS10N
NISTOS�IC PkESERVATIO
.I
1 1
DRAWN: JM/MS
-A� SCALE:AS NOTED
JOB#:
SHEET NUMBER:
REVISIONS:
23'-0"AS BUILT SUN PORCH
a
Ll Li H
4 X 4 POSTS
(TYPICAL)
2' 10"X 4'-2" 2'-10"X 4'-2" ENTRY DOORS 2'-10"X 4'-2" 2'-10"X 4'-2"
GLIDER GLIDER GLIDER GLIDER
22 O"
S-BUILD PIRG = in
O Z Z 4 _
a xo
-- - j p2X RR 2X8RR X
�
@ 16" O.C. a�
Z
= AS-BUILT SUN PORCH =
�9 m 22'-0"x 13-6"
Q AREA: 2079F m
its acv O
L-A LL-==j L__j Li 1L_j X p � � X
O In
m m � �
W
GRADE
100
BATH
�
7'-10" X 3'-6
AREA: 27.4r7
SF
I Uj 1
DECK Q
AS BUILT REAR ELEVATIONAREA:--272u I I 7�
Z O O
W
00 I
W KITC EN I
a 15'-2" X 14'-0" I
AREA: 21238 SF
LAUNDRY Q I
7'-10" X 14'-2" a
AREA: 110.95 SF
MSTR BEDROOM D I Q ►-� r�
20'-2" X 13'-11"
AREA: 255.15 SF DINING ROOMas
I
^�
15'
14'-0"AS-BUILT PORCH A E' X 12'-10" ROOF
A:
194.83 SF I OVERHANG W
MSTR BATH ABOVE
7'-10"x 8'-10"
— M
— — _-- AREA: 69.14SF I O
--_
FF3 ® IIIIIIIII VIII I II IIII IIII !IIIIIIIII Iillll I
s�
— ---- -- -- SLATE PLATFORMON
o
r rn o
GRADE p °o"
LIVING ROOM -�
I I 22'-4" X 14'-3" C
2
AS BUILT RIGHT SIDE ELEVATION
l AREA: 307.89 SF
�S . kz r
a
U)
ul)
+
ow3
w
H
U
O
U)
Lf)
9
14'-0"AS-BUILT PORCH
-
6'-10"
X 5'-9" \' N
AREA: 39.3 SF PARLOR
15'-2" X 12'-8"
— — — — — AREA: 19220 SF
W
L�L=j
O WALL KEY
EXISTING WALLS TO REMAIN
WALLS Tn ctc n�r.�ni icu�n
a PROPOS
q ,'.,I
�'"� „` DRAWN: JM/MS
GRADE
SCALE:AS NOTED
JOB 4:
I I 2
AS BUILT FIRST FLOOR PLAN ..r,:. r
it �j � SHEET NUMBER:
�� Scale:1/4” .1'-O" R .d
s
AS-BUILT LEFT SIDE ELEVATION ' ���' 3 `' ��'
3 Scale:1/4" -0" •� � o "� A 1
a�a�iE.
REVISIONS:
7/8/21 AS-BUILT
1/5/22 DH Window
23-0"AS BUILT SUN PORCH WITH NEW WINDOWS 6"
EXISTING PAINTED WOOD
LI LI DOORS TO REMAIN - INSTALL
ANDERSEN 400 SERIES D/H WINDOWS GRILLES ON INTERIOR AND
WITH SIMULATED DIVIDED LITES-GRILLES EXTERIOR AS SHOWN ON
ON INTERIOR EXTERIOR(TYPICAL) ELEVATION VIEW.
4 X 4 POSTS
(TYPICAL)
S-BUILD-PORGH W1Tk#-N
EWINQOWS
PATIO ON GRADE
_ PAIR 5'-O"x 6'-8"
8310-2 18310-2 ENTRY DOORS 18310-2 18310-2
D/H D/H D/H D/H p
C)
w
m 2X RR 2X8RR Z
Z @ 16" O.G. @ 16" O.G.
F-71 LLJ3 F] F771 FTTI F-73
mW AS-BUILT SUN PORCH s
Li
ANDERSEN 400 SERIES D/H WINDOWS 22A: x 13-6 U
Z ,
WITH SIMULATED DIVIDED LITES- GRILLES � m AREA: 297 5F O p
ON INTERIOR EXTERIOR(TYPICAL) O 3 Z O
"k1E
m 0 oo m m O
i
_ o
GRADE V O
EXISTING PAINTED WOOD I CALIGN
I O
DOORS TO REMAIN - INSTALL
�-� GRILLES ON INTERIOR AND r-1-1-I 1[ o
BATH a �N
EXTERIOR AS SHOWN. 1 _ 7'-10" X S-6 I C
AREA: 27.4 SF �T O
PROPOSED REAR ELEVATION h+H
Scale:1/4".1'-O" O
--DECK
- I I O
AREA:-_-272-SF s 00 a
U
Z —
W 00 CD
LL
KITC EN
+x 15'-2" X 14'-0" I
AREA: 212.38 SF
d H ti
- - LAUNDRY d I
7'-10" X 14'-2" a W
AREA: 110.95 SFUTf,
LLUI -LIE
I r
w � �
I,
14'-O"AS-BUILT PORCH MSTR BEDROOM 0 C
WITH NEW WINDOWS 20'-2" X 13'-11" Ij
AREA:
0
5 .15 •!--{
— - - _- - -- — — DINING ROOM
- - - - - - --- — - — _- __ --- 15'-2" X 12'-10„
ROOF
- - AREA: 194.63 SF OVERHANG
I ABOVE
MSTR® BATHM®
T-10"X 8'-10"
O AREA: 69.14SF
--------- LLJII ILLJ [ i
0
v
SLATE PLATFORMLo
a`
ANDERSEN 400 SERIES D/H WINDOWS
WITH SIMULATED DIVIDED LITES -GRILLES
ON INTERIOR EXTERIOR(TYPICAL) � z
PROPOSED RIGHT SIDE ELEVATION _ `� °' `00
_4 "
2%'v Scale:1/4".1'-0" 4' � \
LIVING ROOM 11,
22'-4" X 14'-3" C3
AREA: 307.89 SF
00
- - - - ---
FN
171
n O W
tl
Z
ANDERSEN 400 SERIES D/H
U �
WINDOWS WITH SIMULATED
DIVIDED LITES - GRILLES ON
14'-O"AS-BUILT PORCH INTERIOR� EXTERIOR(TYPICAL) U)
WITH NEW WINDOWS
- =- -- - - - - - - - - - - - - FOYER
-- - _ - 6 -10" X 5'-s" PARLOR
AREA: 39.3 SF
15'-2" X 12'-8" U
AREA: 192.20 SF U)
O WALL KEY
EXISTING WALLS TO REMAIN
DRAWN: JM/MS
WALLS T
SCALE:AS NOTED
nl a� PROPOSE �. .i � ' JOB#.
`. � ;
SHEET NUMBER:
PROPOSED LEFT SIDE ELEVATION PROPOSED FIRST FLOOR PLAN ;► ' � r -° p
A2Scale:1/4"c 1-0"
��
OF 1�1Zg