HomeMy WebLinkAbout49012-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49012 Date: 3/10/2023 Permission is hereby granted to: King, Lindsey 131 Maple St Brooklyn, NY 11225 To: construct additions and alterations to existing single-family dwelling as applied for per SCHD approval. At premises located at: 890 Arrowhead Ln, Peconic SCTM # 473889 Sec/Block/Lot# 98.-2-6.1 Pursuant to application dated 2/21/2023 and approved by the Building Inspector. To expire on 9/8/2024. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $784.00 CO -ADDITION TO DWELLING $50.00 Total: $834.00 Bubding Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 46 Telephone(631) 765-1802 Fax(631) 765-9502 htt ://www. ou,tltoldtownn . oV Date Received APPLICATION FOR BUILDING PERMIT L C t 11 quiRD , For Office Use Only FEB12023 PERMIT iVO. Building iraspectzar. T tNOE . El Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant Is not the owner,an Owner's Authorization form(Page 2)shall be completed. Datc 2/10123 OWNER(S)OF PROPERTY: Name:KEVIN AND LINDSEY KING SCTM#1000-098.00-02.00-006.001 Project Address:890 ARROWHEAD LN PECONIC NY, 11958 Phone#:(646) 322-2441 Email:LKING@CRESNIEW.COM i sticknyc@gmail.com Mailing Address:131 MAPLE STREET BROOKLYN, NY 11225 CONTACT PERSON: Name:KATE SAMUELS Mailing Address:25235 MAIN ROAD CUTCHOGUE NY 11935 Phone#:631-235-1177 Email:KATE@SAMUELSANDSTEELMAN.COM DESIGN PROFESSIONAL INFORMATION: A1.."__m.1/A Tr /'1 A A AN Irl r% Mailing Address:" Phone#:11 Email:" CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition WAlteration ❑Repair ❑Demolition Estimated Cost of Project: 6 ❑Other 00,000 Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes WNo 1 rc PROPERTY WFOR ATIO d';i 1.a arf r.ii ,'ni �#"ila,�.r2,Y„wy'11t,�1 i`t 4'q P�t�tr.„"r�'�Sti"ia"nJlr+�l.'S�°N' � 4r ' �S"d d4 �I'd r "?�N Y1•',bPSI� �9116� 6"4 4" 7 Qa2,1rP ISI'; ''4' �l•1'..� �1 r 'R-40 n4 "II t a e)ii p iif ,P� tlhd vwn q^arrw^d(anolidti,.r nyr ra i,wraa )II ia.,Pon ar°tm f a a"d ,ne"I YT.T,re r r -. 11W il Pe a;wi Pd ryi M-wMLp"Al W"ills H5 RCRs.1M 1AAM U,0n,Baerl4,6atl'ryy yr�rr'&>La a�ruS ynrz C+rr¢awwud�aB+ ^+ad z ui„aa rti'rin,p��w ro r.�rei a.0d ru,r� „r Yr�a�r 9,"1."1 r° pr t1n5"lar„ro of th o V(Iwfr njvwurtl w aV "aJaHahkf(`Otirtty,New Vark"And Whet ay,qyk4t,ahRaw 6,w",% rhe(jroiVAr ver nw raeY¢taCuaa>n�,,arNt'aAr,poi°uprt e yayr reawut%wr«aV ay” srsrde7hrt,u aoas tlaeteira da^r,teubr;dt.(IM dmarrawda.,mt atxe;,to¢c nlow w,uR,h daft Yar•ugc,jbk,igen,ire,nrnwu � em'Shable al.a C Ym6 A rejsr.a ru"u�^:rkor pwrsua„arut to.vt�.iiam 2t015 of thC, stew York St�art�»r8"imA Vaw, is i, �°,;drt" rn pw r awror r � ` g4 I'- y qmt Application Submitted BY(print ro ue),KATE SAMUELS WRAuthorized Agent L]Owner ` Y,"iS,. 7 Ptl"4k drf0 4ReN� 5,g 9t8R ,contract)xkbov I �r3 iim , ifr (S�h e the (Contra uar,Age[,,A w..otpy:uwat G)ffia:ef etc, of irhe say d wr,rk and to kriake a n'd fle r1fls "F'%"^Np �,1�A6"1iR"'b t� ]i t•'kpp�¢'S"1 pp� M IiMk�"m'r'�a koro N,a Nrw w"r�t�ph �u m'�u!w Nope raz P� ",r "* ie~ fl'^�aµw_.cx� Ih .S'U r °�d..,,,r 4 I,�..Y w, �,...stl I .,0., �`„.., r 4 rlseg 4' r .. i;9, �'9,. +"!f"'P� Wd,�" i„+v v, �4.,d� ii d'y w�yir Rrfl,dt°'flP"Vn� " �'.4X Ni"1 I1"C�hd l;d t' ^ r a 1 om�°"rr rril.y el 0 day o Y at479 h v� rr the ap wl, fl u`waal r cw ] - " ,r � . ... w a.m �. t r W �. � i w y p l ����. here.by r�9't&��;Atrtl� e� ., Tn'Ir 10 tip To TI Of OUIbOid Building Department for approval as described herein. 9 r"P l^�r 3r + i A"i.a „ d"�vdrrk'�iiati �a� print Owl,wiONanie, P Generated Software Compliance Certificate "ett 890 Arrowhead Energy Code: 2018 IECC Location: Peconic, New York Construction Type: Single-family Project Type: Addition Climate Zone: 4 (5572 HDD; Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 890 Arrowhead Ln Peconic, NY 11948 a";i"�:%l��"fl{�''o,Y7�MG�/�l1,� �z,��N/l III J�dV,�JB)il"�'.°Nil�''%�,�bG!��l 4��1fl�s'lr' �P�I�G1�1 K�1,{r"'?m:r (�'oi�✓''7 ,� +,iro r , I"o"P l V7°ry.�a:e i�pn a .�r.,� aY,,-,+u�r 8lA' :,rsf/ ,.eor i 1 tl�',.,:o,, �r�'', +m I w Compliance: 24.5%Better Than Code Maximum UA: 593 Your UA: 448 Maximum SHGC: 0.40 Your SHGC: 0.34 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs ars: no longer considered in the UA or performance compliance path in REScheck. Each slab-on grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements, Envelope As_se_mbiies Gross Area Cavity Cont. Prop- Req. Prop. Req. Perimeter Ceiling: Cathedral Ceiling 1,700 50.0 52.0 0.010 0.026 17 44 Skylight 2: Metal Frame 24 0.500 0.550 12 13 SHGC:0.39 Wall:Wood Frame,24"D.C. 2,850 19.0 22.0 0.025 0.060 53 128 Door:Glass Door(over 50%glazing) 139 0.320 0.320 44 44 SHGC: 0.49 Window:Wood Frame 578 0.480 0.320 277 185 SHGC: 0.30 Floor:AA-Wood joist/Truss 3,067 50.0 52.2 0.010 0.047 31 144 Basement Wall: Solid Concrete or Masonry Wall height:4.0' 600 19.0 22.0 0.024 0.059 14 35 Depth below grade: 3.0' Insulation depth:4.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version :REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date ....... _.............. .... .... Project Title: 8903 Arrowhead Report date: 03/01/23 Data filename: Pagel of 9 RESc eck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 93.0% were addressed directly in the REScheck software Text in the "c-ornmentslAssumptions"column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. .. �w PIanV luef�ed F�eI V luef�ed P -[- ..__... a e,.A _ _-[-Comments/Assumptions..s Section .. pl .. & Re 1D _. o. !t 7Pr,-Inp,'ect1on/PIan ons Review � x Complies? Comments/Assum t� 103.1, ;Construction drawings and ❑Complies Requirement will be met. 103.2 Aocumentation demonstrate ❑Does Not [PR111 jenergy code compliance for the ❑Not Observable building envelope,Thermal :envelope represented on ❑Not Applicable construction documents. _........_ _ _. 103.1, ®Comlies Requirement � Construction drawings and p q be met. 103.2documentation demonstrate ❑Does Not 403.7 ;energy code compliance for [PR311 lighting and Mechanical systems. ., ❑Not Observable ;Systems serving multiple ❑Not Applicable ; ;dwelling units must demonstrate compliance with the IECC Commercial Provisions. 403.7 sized per ACCoolin equipment is Heaton Heatir�..w�_ _.....q i e �...t.. w ,Heating and gg: gw ❑Complies Requirement will be met. A Manual S based Btu/hr Btu/hr ;❑Does Not [PR2h on loads calculated per ACCA Cooling: Cooling: ❑Not Observable ` Manual J or other methods Btu/hr � Btu/hr approved by the code official. ;❑TVot Applicable k , Additional Comments/Assumptions: 1 Hill#rrrpact(Tier 1) 2 �+iedrum Impact Mer 2)".' 3_,.� `Low Irrwpact(Tier 3'► Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: Page 2 of 9 p Pibr !"�uefled Feel Value verified. _..... _. „�u._. ..,�. . s/As _ prions c se€tloun 9R+a ID �rnt �pwssuro tix�n�X ". _....� Foundation Inspection .... . ...._. �_....�, .�. .. ...._. .._ Iles Comte.. Comp 402.1.1 Conditioned basement walla R- R- ❑C'omplies See the Envelope Assemblies [FO411 'insulation R-value.Where interior R- R- ;❑Does Not table for values. j insulation is used, verification [(Not Observable :may need to occur during Insulation Inspection, Not ;❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 ;;Conditioned nd tion installed basement wall � � '� ®Com plies hot Requirement will be met. [FO5] p manufacturers instructions. E]Not Observable nNot Applicable 402.2.9Conditioned_.__...�.__ ...�w�,..__..�_..�..-..... ...._.. __.... . ._. basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]) insulation depth of burial or ''DDne tab '€ " l ke . ;distance from top of wall. IF]Not Observable : I a []Not Applic_able .... 303,2,1 PA protective covering is installed `❑Complies ;Exception: Requirement is [FO11]"2 'to protect exposed exterior '❑Does Not not applicable. �p insulation and extends a []NotObservable minimum of 6 in.below grade. ( Nat Applicable 403.9 Snow-and ice-melting system „ ❑C'omplies Requirement will be met. IF012,17 'controls installed. ❑Does Not oNot Observable ❑Not.Applicable Additional Comments/Assumptions: 1 rFirglr#tr€pa€t(Tier 11 Medium Impact(Fier 21.....' _ ier ) _.. I � . .. fie., .stow Im pct#T ` 3� Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: Page 3 of 9 Sec#t€an _ . , PI_a_ar Verified FieldVerified /Rough In InspectionValueraming ValueComplies? j...C...o mme....n....t..s._/.A.�s._�sumptio..n.�s & 402.1.1, 4Glazin9U-factor(area-weighted U- _ U- ❑Complies ;See the Envelope 402.3.1, average). '❑DoesNot table for values. 402.3.3, ; 402.5 I❑Not Observable '[FR2]1 ;❑Not Applicable 303.1.3 LI-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not ;with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.1.1, Skylight .. U-factor, U_T:,.._. . U ....�.. � ®Complies 'table a E� �_....... kyglight � � Envelope Assemblies 402.3.3, ❑Clues Not lues. 402.3.6, 402,5 !❑Not Observable [FR5]1 ❑Not Applicable Air barrier and thermal barrier OCom lies Requirement 402.4.1.1 Aip will be met. [FR23]1 installed per manufacturer's ❑Does Not i instructions. r '❑Not Observable ❑Not Applicable ' 402.4.3 Fenestration that is not site built � . � �ODoes" —� � ,, plies `Requirement will be met. [FR20] Is I ted and labeled as meeting Not 'AAMA/WDMA/CSA 101/l.5.2/A440 ' � ❑Not Observable :or has infiltration rates per NFRC -400 that do not exceed code ❑Not Applicable li m its. 402.4.5 IC-rated recessed fighting fixtures ElComplies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.3.1 'Supply and return ducts in attics ❑Complies Requirement will be met. [FR12]1 Jnsulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ ' xa w „ - here< 3 inCheS<Supply and ❑Not Observable Applicabie return ducts in other portions of the building insulated >= R-6 for 'diameter>= 3 inches and R-4.2 ';for< 3 inches in diameter. wmm � 403.3.2 Ducts, air handlers and filter ❑Complies ;Requirement will be met. [FR13]1 boxes are sealed with ❑Does Not ,:- .� ;joints/seams compliant with ❑Not Observable a 'International Mechanical Code or international Residential Code, as ❑HotApplic"abie applicable. 403.3.5 Building cavities are not used as ❑Complies ;Requirement will be met. [FR15]3 ducts or plenums, '❑Does Not �i ❑Not Observable ❑Not Applicable �. A03.3.611, ....�......_ 61 n „r c..mp tole. .�...,�. ��cts,; r*..,Il, .,. �.,,,,Yle.". ; ❑Cor�pties Requirement will b�met. 2) buried in cejljng insulation have "°❑Does Not [FR26]3 an insulation R-value not less ❑Not Observable than R-8,the sum of the ceiling insulation R-value against and ❑Not Applicable above the top of the duct, and against and below the bottom of the duct, is>=than R-19, excluding the R-value of the duct insulation_ 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) . .__ ._u� ._... .. Project Title: 890 Arrowhead Report date: 03/01/23 Hata filename: Page 4 of 9 Ver Framing/Rough-In lns�pwdectl�onn lila Valu+ #led. diel ruelfied corn es .... ? comer.. S+ tion _ -111-e ... g 9 P Fa �e lteg l0►] 111-1-1-1111 ents/A� ions11. 403..x./ Ducts declared to be within the �'" � � � �� ���,nCmplies Requirement will be et-�" IFR281� conditioned space are either 1) ❑Does Not completely within the continuousNot Observable ` :air barrier and within the building ❑ thermal envelope,2) buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is<= 1.5 cfm/100 square feet of conditioned floor area served by the duct system,or 3f the ceiling insulation R-value installed against and above the insulated duct>=to the proposed ceiling insulation R-value,less the R- value of the insulation on the 40 .4 .,:HVAC piping conveying fluids ...... R-��oo_ ..... .m. .. M _.... .. �_ �........... -�� �; R- �',❑O'omplies ;Requirement will be met. 1FR'lyj above 105 4f or chilled fluids ;❑Does Not below 55 RF-re insulated to?it- k 3 ;❑Not Observable 'u ❑Not Applicable 40 4.� Protectioncement Re of insulation on HVAC �� � � � " �� +�� lies ui �will be met. � p q 24] ,piping. Does Not ❑Not Observable :❑Not Applicable 403.53 ;:-tot water pipes are insulaFted to _Y,.R .. R-oma. ._� ;❑Do. .. _...-. ..t... . .. -' --� orraplie ;Requifemerrt will be met. 1FR18lr2 2!R-3. oes Not FINot Observable ❑Not.Applicable ,,. ., ,. o, ,,. _..mm �..... ........ . 403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. (FRI917installed on all outdoor air ❑Does Not intakes and exhausts. ,❑Not Observable ❑'Not Applicable ` Additional Comments/Assumptions: Hi h lm Batt:(Tier 1� Medium i _._...._�.._.. LOW �J 1 g p___��.W.. � _... larip�att°(Tier 2# 3 lmoww Impact(Tater 3p Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: Page 5 of 9 _. ... ... ..An Plans mer fieri: lel eComplies? OConanixrlfi insulation Inspection onf 1N�surwrp�tlarraws .3 1 All installed insulation is labeled ElComplies Requirement will be met. (IN'.V'' or the installed R-values ❑Does Not 'Aivprovided. ,[]Not Observable ❑Not Applicable _.e.... , .. .... ., .. ... ... � .. ....... 4D2.1,1, Ffoor insulatkm R-value. R- R ❑iMomp ies ,Se`the Envelope Assemblies 402.2.6 ❑ Wood !❑ Wood U--IDoes Not table for values. [IN111 ❑ Steel ❑ Steel ;❑Not Observable 'Q ❑Not Applicable �...�. ..... 303.2, ;Floor insulation installed per ❑Complies Requirement will be met. 402.2.8 manufacturer's instructions and ❑Does Not [1N211 in substantial contact with the ,❑Not Observable underside of the subfloor,or floor Warningcavi insulation is in ❑Not Applicabl cavity e :contactuwith the top side of sheathing,or continuous ;insulation is installed on the ;underside of floor framing and extends from the bottom to the ,top of all perimeter floor framing 402.1.1. ',Wall nsu ation R-value.If this is a R- e� _.� R- ❑l'ornplles See the Envelope Assemblies 402.2.5, �mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 ;wall insulation on the wall ❑ Mass ❑ Mass ;❑Not Observable i [IN311 !exterior,the exterior insulation requirement applies(FR10). ❑ Steel E] Steel ;❑Not Applicable 303. manufacturer's insufatio s�instructions.l � p p Req{ rement wilt be m Do s Not 3fY3 2 installed per ❑ met. i ❑ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: i F&r h Impact act(Tfer 1) Mediu n Impact(T er 2) 3 Low Impact M g..p l p �..... ., ,,.f 1 ger 3) Project Title: 890 Arrowhead Report date: 03/0123 Data filename: Page 6 of 9 Final inspection P, _ PlansVerified Field Verified Section Valued Complies? ..... .C. �.. .u..... ... .� . < Provisions � it IDL. .._. .w_. ..__ _. & 1 1 'Ceiling insulation R-value. � R- ,- R- ❑,,. Comments/Assumptions 402. g Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ woo d '❑Does Not ;table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable u 402.2.6 ❑ [Fill; Not Applicable 303.1.1.1, ,Ceilin ....�. — .�,—. e.. P. . �....._. - — g insulation tion installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 ;Blown insulation marked every % ❑Not Observable '300 ft2. ❑Not Applicable 402.2.3 Vented attics with air permeable ❑C'omplies Requirement will be met. - [F122]2 insulation include baffle adjacent []Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 'Attic access hatch and door R�� � R- �y "❑Complies ',Requirement 402.2.4 � will be met. [F1311 insulation>--R-value of the ❑Does Not adjacent assembly. ❑Not Observable ' ❑Not Applicable _ 402.4.1.2— 50 Pa. < test At'.i-i 50 ALri 50 ❑Coco mplRe "Requirement will door ten.." =5 .. @ = all be met. [F117]1 Each in Climate Zones 1-2, and UDoes Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 4 022.4.2 a. tight fireplaces idam vers and - � � - ❑Doe shot • 9 P ;Requirement will be met. 9 9 p outdoor air for combustion. Not ,v, i J 1ot uaeabie ❑Not Applicable 403.3.3 Ducts are pressure tested to _ cfm/100 cfm/100 ❑Complies Requirement will be met. [FI27] determine air leakage with ft2 ft2 ❑Does Not ;either. Rough-in test.Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable Iw.g. across the system including the manufacturer's air handler enclosure if installed at time of ,test. Postconstruction test:Total ;leakage measured with a pressure differential of 0.1 inch w.g. across the entire system ;including the manufacturer's air Chandler enclosure. .. [l 14] cfm/100 ft2 across the s FM — ....._..— 403.3.4 Duct tightness test result of<-4 �l[fl/ZVV Cfm/1VV ❑Complies Requirement-will be runt. 1 system or ft2 ft2 ;❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable g Inspection, g 403.3.2.1 Air handler leakage desi�gnated ❑Complies Requirement will be met„ � � � - _ duras Framing I [1`12411 !by manufacturer at<=2%of ❑Does Not design air flo;.v. -!Not Observable ENot Applicable m......... .................. ......... 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [F19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable * 403.1.2 Heap__. � pump thermostatinstalled '❑ComN!ies ,Req,.xer^"t ..,!l be met. V11012 on heat pumps. ❑Does Not ❑Not Observable ° ❑Not Applicable edium �� ...... Impact(Tier_ Lo 3 � w Impact(Tier 3) 1 High Impact(Tier 1)1) 2 M2) .. Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: Page 7 of 9 ....P Plans Verified Field Verified P , �et�tIon lue ents/Assumptions .. ;Circu I g ecton Provisions Copliese5 Requirement # Final 403 5.1 Circulating service hot water ❑Com be met, [FI11]2 systems have automatic or ❑Does Not ,accessible manual controls ❑Not Observable ❑Not Applicable _....... _..._._ ElCam lies Requirernent will �4 � ,-.-._r , _�-� . > p � � l be met. �03.>;.1 =���n�casi'xar3iLa�ventilation�gStcri� � [F125]2 fans not part of tested and listed `❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable it R403.6.1. ❑ _ Not Applicable 403 2 Hot water boilers supplying heat � � �❑Complies Requirement will be met. [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ;r-,p, F lase ale control to lower bailer water � „ EJNot vuxi able ,.,, �"❑Not Applicable 1 temperature based on outdoor temperature. 403.5.1.1 03.5 1 1 have a circulation ater c ... m __.�... met. Bated water circulation systems ❑Complies :Requirement will be met. 2 pump.The ❑Does Not system return pipe is a dedicated , return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systerns are not present.Controls for circulating hot water system pumps start the pump with signal " for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 03.5.1.2 'Electric heat trace systems ❑Complies ;Requirement will be met. [F12 9]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Nat Applicable desired water temperature in the piping. 403.5.2 � pesRequirement Re uire m�int�w_ill be met. r [FI30]2 systems have ❑Does Not ..__� manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to<= 104°F �.. ._ .... ...- ........� � .., � ... f 403.5.4 Drain water heat recovery units ,% ❑Complies Requirement will be met. _ , [F13112 tested in accordance with CSA n Does Not 655.1.Potab#e water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. .............. _ 403.10.1 Readily accessible switch on ❑Complies Requirement will be met. [F112]3 heaters for swimming pools or ❑Does Not permanent in-ground spas. Switch operation does not []Not Observable change heater thermostat ❑Not Applicable setting. Heater circuit breaker is installed independent of switch. " Gas-fired heaters equipped with ignition pilots that are not continuously burning pilots High p _.� mpact(Tier 2) 3 Low Impact(Tier 3) 1 Hi h Im act(Tier 1) 2 Medium Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: mage 8 of 9 finial Inspection n prdvision ... PlansVerified ._.,Fiel erifietp....,Ve complies? Corrarn.., .... _ ectioxr en /Assum t P inn 403.10.2 Timer switches or other ❑Complies Requirement will be met. [FI19]3 automatic preset schedule ❑Does Not ;control method are installed on `:❑Not Observable heaters and pumps serving pools and permanent . ; ❑Not Applicable com403 i 0 f t)utdoor hpo s as have a ❑DoespNota_ RequirRequirementw. ill be met. [F120] pe heated P ;vapor retardant cover. 'nN!ot Observable ❑Not Applicable 40... r _..__ ........ 4.1 :90%or more of permanent ;❑Complies [FI6]1 fixtures have high efficacy lamps.; ❑Does Not ❑Not Observable []Not Applicable _.__----.......__�,�. rr .a � a� ...... .......... 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable _..._.... _._. ._.... 4013 Compliance certificate posted. ❑Complies ;Requirement will be met. i,l; ❑Does.Not '❑Not Observable ❑Not Applicable ti 3�... ........ mm711 _,.,. 3.3 Manufacturer manuals for „. '❑Complies [Fltsj-'m mechanical and water heating ❑Does Not systems have been provided. :❑Not Observable 4 1 �.....µ.. �.......__�_.� _...�......���m..._ _. ..A...,. . .a. ,,.�� ., ...... .M. .��,� ,. . . _...�,. �❑Not Applicable ,��. .u�_..�.. _. ..4 _.�._._.��,� Additional Comments/Assumptions: 1'Hihlrrmpatt$Tier 1i 2 e iu impact{Tier 2� .m. � 3.�� ...1rinpactMer3i Project Title: 890 Arrowhead Report date: 03/01/23 Data filename: Page 9 of 9 2018 Ii a� 0 8 i+v ECC rmnwum nergy Efficiency Certificate AJ M=MMUMMOMMUNIMUM Above-Grade Wall 41.00 Below-Grade Wall 41.00 Floor 102.25 Ceiling /Roof 102.00 Ductwork(unconditioned spaces): Window 0.48 0.30 Door 0.32 0.49 SkyUght 0.50 0.39 M OEM . . affig Heating System: Cooling System: Water Heater: Name: Date: Comments M'31N039d IL614 3W 0tl wo—068 AN'010H1nos M XOG'O'd NVId 3116,UM-LINVS *3d'1A-L3H0S1=1 Hd3SOP (L .9 z LU N g�p 0 9 95 (L F fTw [a 0(5p 02 P'i ye 11ijil 'j"I 0� 5 �jlj I L)�- Lu ,9 a uj W a 0 Of ow p IT M1,11 gg Hli, JIM pill IM 1,1 i 1�1 M! q FE g" 9 In p 6 a 0- r- MOO U Z< < MWX O V! > =1 z 0 0 z Y < z . ........... 0 0 0 Z 0 W J H < 0 0 4 U '0 z C5 0 z ge ------ lF z < 0 n Lij 0 ARROWHEAD LANE o'. S0117'40'E 310,00' (A —-—-—-—-— Ul1d q '0 C� iG 42 ih 0. z X 15 z .......... < NDI*17'40' 310,00' V now or formerly to 4170 Indian Neck,)Lone Holdings 12 VF OM Scott A. Russell STORMWATEIK SUPERVISOR MANAGEMENT GEM]ENT SOUTHOLD TOWN HALL-P.O.Box 1179 1 rj iO w� O�Southold (YO u r/l O J r`(,�7 53095 Main Road-SOUTHOLD,NEW YORK 11971 },} R 236 - STORMWATER MANAGEMENT REFERRAL FORM (APPLICANT INFORMATION TO BE COMPLETED BYTHE°APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) APPLICANT: (Property Owner Design Professional,Tonal, CgentContractor, Other) Ii NAME: I Date: 1pr Ir Contact Inforrriatio i IE—Mail&Telepl¢me Nuntu) 1 P!Merty Address / Location of Construction Site: S.C.T.M. s 1000 �r District Section Block Lot. TO BE COMPLETER BY SOUTHOLD TOWN ENGWEERING DEPARTMENT - Area of Disturbance is less than I Acre., No S.P.D.ES.Permit is Re uired 1 - Project does Not Discharge to Waters of the State. No SYDE '«Pewit amu I fl - Area of Disturbance is Greater than I Afire& Storm-water Runoff Discharges Directly to Waters of the State of New York. LHE APPLI ANT MUST OBTAIN a. .P D.E.5.PE rmtt DIRECTLY :om N.Y.S. D.E.C.Prior to Issuance of a BulldlM Pernlit. 0 - Area of Disturbance is Greater than 1 Acre&Storm-water Runoff Flows Through Southold Town's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a ,RD.E.S.Permit through the Southold Town EpSMIng,Department Prior to WMance of a B ildi Permit. Reviewed 11, 14 Date: ix VnRM WrP-1nvnrtr4.,'7n14 e eceivcd 7 23 � � q 5--A-•-6 ,, I ARCHITEC r'S: A,52�ws 6/� " - ,5S&�, rk'vING RENOVATION - L 12. ALL WORK OF THE VARIOUS TRADES INVOLVED WITH THE GENERAL NOTES s � ' E E L M A N ' CONSTRUCTION OF THIS PROJECT, IS TO BE PERFORMED DRAWING I N G LIST■ 25235 MAIN ROAD 1. ALL WORKS SHALL BE PERFORMED IN ACCORDANCE BY CAPABLE AND REPUTABLE CONTRACTORS, LICENSED IN CUTCHOGUE,NY11935 ATE, MUNICIPAL, LOCAL ZONING AND BUILDING , ;:. =_z ,'.: {.-! -� .. �,,. ,4, , , . THE STATE OF NEW YORK AND AS REQUIRED BY THE LOCAL ;.''. , .. :" . :, T-100.00 TITLE SHEET ,. SITE PLAN „ ; z w ;p4.' , , z� '. :: TION AND BEST GOVERNING AGENCY. „ , :I � �` ;,,:, ST-100.00 SITE PLAN :x<.. . STANDARDSCONSTRUCTIONPRAC13. ALL WORK OF THE VARIOUS TRADES IS TO BE .g,, ..wa"'.Y.x=8l a'„�r.,ee`><v^ �3'h��i' Jli s SEPTIC PLAN RA: .:513. :.t.� :, V a 'Q �-:;r?« a:�.:t? .. s .::_m,*:..,,, 7 .<: ":�r..'r^,Sa:'. a,.,.',\ .:o ,p . . , , .. :.:. . ,',', \.::::::,.,, TIONS PERFORMED IN ACCORDANCE WITH STAT t . _a .. :xr . >: .:,, A 001.00 BASEMENT PLANS 4 1... , - SHALL APPLY TO OIL WORK PERFORMED ON THIS PROJECT. ,:.. .. , ..,a. .\...,,,. . I ' ll ..:�,,. I.,,�,a:.,, ,-.. '�, CODES,;_. , E AND ALL OTHER APPLICABLE AG NC ED OCDA M < >� { g SA �...ar . ,. x, � . ,_:, ,,.::,: A-001.0 t .. a .. key ;..° « ,...3'a,..` ,ayt\``'..::v...i:..'•� ., ..Y.", .. ...<. ..`a ga_: ,.�.Z .. 3x a . ...:.., gym,`« _°t`.••r•,M ���\. ''•moi., - 11 - ;. _ �.�. .:.. w� ..._ ,_ � <_ , :' 0 1ST FLOOR DEMO 1,r .,. , ex >: .,..:. ., HE DE, AND AS RED Ate, THE CONTRACTOR SHALL VERIFY L r OI CONDITIONS CT T :,,.,,•> <,.,.,<_ _ : <. TRA < ` �R- SITE. ANY DISCREPANCIES MUST BE BROUGHT TO THE R / �^�E Ch' STANDARDS GOVERNIN TH T . ICULA ;_,�: - w- - ^< ::: HEREINAFTER STATED OR IMPLIED. JEA R. G A PART A 002 00 n <.< , R DEMO E ..' A 100 00 FIRST FLOOR PLANS N 7' -, �< ,A F' .,:::::",. ,:._,:", , ::"... .,, ..,,,..:::.,, . ." »� .. . ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT 4~ v, - - .�, 1. ,.,f .. ,:, ,<_`,, ,.a „ ,° " � .. 14. ANY WORK HEREINAFTER STATED OR IMPLIED WHICH IS c " 92,, Oma, .. ., ., ' , � :: .,m�.� A-200.00 SECOND FLOOR PLANS a*+^""�°. :,.�^"°�.,,..r"".Yrw+""<. ....r<+^-:a✓"`:',.'.'r .« .." 'e ,kz?° m. .r n .._,,:< ...,, ,,. ,,,,, .. .,':.,, „„ <.;..'°'l .': ': .: .. ." w`M .p ...- "`",",^�w ;aw G ,�F., ,, a ...,. .:e -m:F..:.'.an k. , : e'=' .,.�, e,: _ ,,-\ 1.,, �yyl. .,�1'\a,< v:•.ih'§` .�a ?,», .,}�, -sr?.. .1'+. L ,:. . T R ALL BE THECONTRARY TO THAT RE REQUIRED BY THE P �_ � H A , , ... :. .° APPLICABLE t� ., : .,::,;;,;<.;.,<.:. ,..,.'- � „ Via,„ :,A': ,, ;2 A 250 00 ROOF PLANS ,- �. ; _.:, < �Ii,.,.. . :. '., ; a<•.,._:., . ,:.,>.,,, RESPONSIBLE FOR CORRECTIONS NOT REPORTED ONCE HE w cn X .: „- GOVERNING AGENCIES AND CODES IS TO fir . E r BE BROUGHT TO ,, . ,..,,. b , ,, � .. <.., v, F. ;, „ .e. �,,,w.. .<. .P» .. . . .,.. { ,., \ v s, ,..�'`.. ,e ..dln d.. .l.,n^�`;,. �:.:,' ...h.�\=\n, �.,,,,,.`n:\,.,,,.,,C,::.::., a'a� ,..,oy A 300 00 FIRST FLOOR ELEC PLANS .�_ : .., \,, ,Y ;,� 4r` ,,.: � A NS, THE ATTENTION OF THE OWNER, AND CORRECTED IN _ „we°'a:�-a"0"..., ',.,,a',, ra,`.>"`y' ,>�"v'_, '^ .. ,':.:.«:;�s,n�'94as**;kY+.stararet ' '` ...a 'MMW. ,�° ,ro"",.�,.- :p :r . . ^s:r :, .,<.v �k.•,. �,n,•, wa y,<. . •,' ,,,,,> ....'. , :X.. * . ,.... _ ANS ..r:.;o- . M,x , ,.. ., ,.' M N � -, 3. WIIL BE OF GOOD QUALLTY, FREE FROM FAULTS END R ELEC PL SECOND FLOG r .>„v,:.: .: ,_ ..- . : ,,, :; '."a':'' . , , - ,,-.: CONCRETE I/A OWTS General Requirements COLLAR 24 STOPPER END R PLUG 1.Installer shall provide a certification of the Installation and construction(W.W.M.-73)from a PROFESSIONAL ENG 4EER OR REGISTERED ARCHITECT for final approval of the system C/ RISER & COVER �: 2.The installer of I/A OWTS must hold a current Liquid Waste License pursuant to Chapter 563 Article VII(Septic Industry Businesses)and Endorsement J(Innovative and Alternative Treatment System Installer)through the Suffolk County " 1 8" PER FOOT MIN. Department of Labor,Licensing and Consumer Affairs,pursuant to Suffolk County Code§563-79(11)(J).The Department 1 I PER FOOT MIN. PITCH HOUSE RBER JOINT of Labor,Licensing,and Consumer Affairs maintains a list of licensed I/A OWTS Maintenance Providers. MIN. 4" DIA. SANITARY PIPE PVC WASTE LINE ELEC. PACKING 3.An executed Operation and Maintenance Contract between the Maintenance Provider and Property owner must be SDR 35 SDR 35 submitted to the Department WATER TIGHT FRAME & COVER PANEL CI SEWER PIPE HOUSE CONCRETE COLLAR W/ APPROVED LOCKING DEVICE (TYPICAL) 4.All installed I/A OWTS are required to have an initial 3-year warranty and operation/maintenance service contract. F.F. EL. 33.9 TO WEIGH 60 LBS. MIN. OR 20" D-BOX W� PVC PIPE D3034 5.When an I/A OWTS requires a vent,the unit shall be vented to the roof of the residence being served.Vent pipes shall SECONDARY SAFETY LOCKING COVER HEAVY DUTY CAST EXTERIOR RATED CI 3d SDR 35 extend a minimum of 6 inches above the roofline and the top of the vent shall have a minimum horizontal separation of 12 STOPPER END PLUG JUNCTION BOX BELOW BEND inches to the sloped portion of the roof.In cases where it is not practical to vent the system to the residence roof,a vent LIDS DEVICES TO BE PROVIDED AND SECONDARY pipe P'P g IRON COVER TO GRADE GRADE IN TO SEPTIC p p may be piped to the exterior side of the residence and terminate a minimum of 18 inches above rade.These vent SAFETY COVER SPRINKLER BOX 20 AMP BREAKER FROM DWELLING TANK pipes shall be located a minimum of 3 feet from any window or doorway and must terminate with a carbon filter device.All EL. 26.5' AT GRADE - -�-- vent pipes must have a minimum diameter of 2 inches. 27 E. EL. 26.0' I Provide 2"vent pipe from the OWTS To the single-family dwelling and connect to the waste 8'm in. " C.I. 60° PVC WYE CI TD PVC pipe venting system within the house.Pipe shall have a positive slope from the OWTS to the 1 MIN. 6 THICK CONCRETE HOUSE ADAPTOR house so liquid will drain toward the treatment unit FLOW�]� 2 MAX COVER I Q_ w 4+' � PIPE 1'E CLEAN O lJ T DETAIL 6.Garbage grinders shall not be permitted when an I/A OWTS is utilized as means of sewage disposal.In addition,water Z CLEAN OUT I•E. I.E. N-12 softeners shall not discharge Into and/A OWTS.24.6 24.5' 23.8' I.E. fW 23.6' I E AWG OF WIRE 7.Install IIA OWTS tanks according to manufacturer's recommendations.All applicable recommendations provided by the FLOW "' IN " PVC SCH N .T. S . p Z 23 2 manufacturer shall be implemented -- Q 8.O 80 CONDUIT w U LINE 50' _ 8.The I/A OWTS tank shall be installed at level in all directions(with a maximum tolerance in any direction of+/one rn = quarter Inch)on a minimum 3-inch thick bed of properly leveled and compacted sand(free from rocks)or pea grave v/ Z . The op of the A OWTS tank shall not be located greater than 2.5 feet or less than one foot below final grade. O O [2] LEACHING POOLS (8' DEEP) 4 HmROACnON USA 9thI/ � CONTROL PANEL wQ d ��,� [1 J EXPANSION POOL (8 DEEP) 3.0 MIN. Electrical Requirements HIDROACTION III=11�I I- 11111=IIII-11 11=II II-IIII=11111''='IIII- ELECTRIC R I S E R DIAGRAM Q � AN500 I I I=1 I I=1 -1 I=1 I I=1 I I-1 I I I I-1 I I I=1�" "'=1n =11111=111 I- II I= I-111 1=III - c rX 1.Control a.All Panels and equipment are to be installed b the electrical contractor In accordance with the 00 O HEGW 2.0 ,,.>>;.:,;�:::r�::�. gy GROUND WATER I v ,T. S , x:* � National Electric Code(NEC)and local codes. EXCA VA TE ALL UNSUITABLE SOILS t;'' .r :.;`:, _<< :;.:,:;_, b.The control panel box must be placed outside on a suitable pedestal near the structure that it serves. >:.,,, ,2, Alternatively,the panel box may be mounted on an outside wall of the structure(preferable a utility z BACKFILL MATERIAL TO BE CLEAN SAND & GRAVEL POLYLOK 20" �, .,i { !:: i:':': ' room,and not a living space). DrsTRreurlON B0,1 ' I ' 4 ' ' c.The control panel shall be placed at a comfortable height for access. 4�-w------' LEACHING POOL D ETA I L ✓t/ LOCKING COVIR rTr rrl>t�m r, d.The panel shall meet National Electrical Manufacturers Association(NEMA)4X specifications. ' AND SECONDARY e.The conduit must have appropriate seals to prevent gases and moisture from reaching the control v J H Y D R O A C T I O N AN500 'T.........:..........._........:M............._.. SAFETY COVER AT panel orjunction boxes. GRADE f.Each system shall be equipped with a functioning warning system which will activate audible and V,1 LOCKING COVER D ETA I L visual alarms thatcan be readily seen and heard by the occupant's of the building served. FROM OWTS N'T-S. 2.Pum s Blowers,Level Sensors,and Controls SAN ITARY SEPTIC SYSTEM P R O F I L- E TO LEACHING FIELDS p a.The electrical junction box serving the pump motor and floats must be watertight and located outside \ 4REMOTE PLC CONTROL PANEL the I/A OWTS tank chamber. PROVIDE SPEED LEVELER W/ HP80 COMPRESSOR b.The Department shall observe the pump system operate through a normal operating cycle. N • T • S • ON EACH OUTLET c.Inspection for leakage of the force main fittings will be made during the pump test procedure. 12" THICK UNDEPIRAIN FILTER MATERIAL TYPE 36'X 36'X 6' WITH 6X6 10/10 WIRE LANE P O LYLO K D-BOX DETAIL General Construction Notes NECK CONTROL PANEL 8c AIR PUMP ELEVATION INDIAN N•T�S� 1.LOT AREA:41,846 SF N.T.S. 2.SCTM#1000-098.00-02.00-006.001 OP 3.BOUNDARY AND TOPOGRAPHIC INFORMATION FROM A SURVEY BY FOX LAND SURVEYING,Last Dated Ln 9/14/2022.ELEVATIONS REFERENCED TO THE NAVD 88 DATUM L -P- O 4.ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS J OF THE TOWN OF SOUTHOLD AND THE SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES AS REQUIRED 5.THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF WORK,THE CONTRACTOR IS ADVISED ALL SUBSURFACE INFORMATION SHOWN ON THESE m EXCAVATION INSPECTION REQUIRED PLANS IS CONCEPTUAL AND MUST BE CONFORMED ACCORDINGLY IN THE FIELD. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS BEFORE COMMENCING FOR SANITARY SYSTEM WORK. " PUMP/�COMPRESSER POWER CIRCUIT 120105 By HEALTH DEPARTMENT � U OG -SII CHl 7.ALL UNSUITABLE MATERIAL AND DEBRIS SHALL BE DISPOSED OF IN ACCORDANCE WITH TOWN,COUNTY,STATE Lot 3 7 0 , 1 Mi �L AND FEDERAL LAWS.CODES AND ORDINANCES.CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OFF ALL (Dwelling - Public Water) 111 I Ll "" _" r ""�,�Pyi ' SPRAY L11 UNSUITABLE MATERIALS OFF SITE.DEBRIS SHALL NOT BE BURIED ON THE SITE. J 76 > N VHr r vRr t fr l -----� M❑T❑R ,'PUMP RATINGSI 8.ALL PRECAST STRUCTURES SHALL BE APPROVED BY THE COUNTY AND COMPLY WITH THEIR REGULATIONS. FEN -P 0 � `., �/ 3/4HP @ 115V 0.8'E N 8 8°42'2 0"E '" C_B2 M2 CSR 6 LOOPS IIF-O���` 15,0 F.L.A. 9.ALL PRECAST STRUCTURES SHALL BE MANUFACTURED WITH 3,000 PSI 28 DAY STRENGTH CONCRETE. 135.0 0' �" CL >�X �X r >�X P -----J RECIRC PUMP RATINGSI 10.SANITARY PIPE TO BE SDR-35 PVC ORAS SPECIFIED ON PLANS ELECTRICAL FEN CHAIN LINK FENC 0.SN -� PUMP 13/4HP @ 115V CONNECTION D.0'E 0. TI= yM yM TL-__ 1 / IN CONDUIT '• �� �� r I N �� --y MOTOR / 15,0 F.L.A, 11.DURING CONSTRUCTION,EROSION AND SEDIMENT CONTROL MEASURES TO BE UTILIZED AS NECESSARY TO EL=24.7 EL=26.4 77 �f��`�_ �/ PREVENT THE TRANSPORT OF SEDIMENT TO OFF SITE AREAS,PONDS,DRAINAGE INLETS.THE METHODS AND CB3 II' �% �r MATERIALS EMPLOYED IN THE INSTALLATION AND MAINTENANCE OF EROSION CONTROL MEASURES SHALL su< ax M3 xx P r`t����v MIXER��PUMP RATINGS, CONFORM TO THE NEW YORK GUIDELINESFOR EROSION AND SEDIMENT CONTROL. vRr k- I PUMP 3/4HP @ 115V 12.ALL BACKFILL SHALL BE SELECT GRANULAR MATERIAL COMPACTED TO 95%MAXIMUM DENSITY AT THE OPTIMUM ' N ----- I\ MOTOR / 15.0 F.L.A, MOISTURE CONTENT AS DETERMINED BY STANDARD PROCTOR TEST. W CON ROL PANEL ! Lo� 36 G W/ HP80TCOMPRESSOR jam/ 13.ALL COVERS ON TREATMENT UNIT SHALL HAVE LOCKING COVERS CB4 0. I ( r" rR, r�r C1 ----_J C❑MP ��COMP. RATINGSI O 11 TT 11 t I 1/4HP @ 115V PROVIDE 2"VENT PIPE FROM THE OWTS TO THE SINGLE-FAMILY DWELLING AND CONNECT TO THE WASTE PIPE VENTING ., } NEW DRYwLu m E W" __ MOTOR I SYSTEM WITHIN THE HOUSE.PIPE SHALL HAVE A POSITIVE SLOPE FROM THE OWTS TO THE HOUSE SO ANY LIQUID FOR O H D-D3 N - ---N / 5,4 F.L.A.O WILL DRAIN TOWARD THE TREATMENT UNIT. SI ORMVVAICR \ • �/ �/ RUNOFF 18x4) • LJ- I 1 Ev r� N❑TEI ALL MOTORS f �-26-- - r I �N ❑VERL❑ADMUST HAVE INTERNAL W z DEEP LA x 8' -P m PR❑IECWIRT Z O O DEEP LP LP O -4 aal LRl-Ql FEN \ LP LRl-Q2 PDK�WM vRr o sIZ AI '�" Z d- J I I F W L E nu } � ,,,.•� T 0) 0.1 W D-BOX PnaivW J ECIR UNNING ,. r , J O N Q 00 B 104 ILD LR1-03 Ya/w v"T V Q (n Ln O PROP JE 111 M3 .. Cfl TANKS NEW B97J roivR G ; v/ Z r f` • SINGLE wo WELL TO BE / F I ER RUNNING :.• O REMOVED •�STORY o Sul vRrPOOL GARAGE LRI-Q4 EQUIPMENT F.F.26.5' TEST HOLE / �16' LC INPUT ` LL w M 'T 64 J • / I AIR LINE C-CZ SLB S-1 rn« fF ��' 1 LL. O -'- 0 m O v0, 1 I Qaaa VENT �' 26 - ^ I ,,, 5 6 � RUN AUDin 0 . � Q'_ _ , 0 \ I I o Az ALARM D_ s W� O e41 HWA MUTE � 177' AN "(NOT TO SCALE) D�A� ON ITEST BY: MARK McDONALD GEOSCIENCE m 3xsc NCRETE W O O -n PAD r R AIR o 66 1 ALARM SOUTHOLD, NEW YORK 11971 m • I PUMP AND 01 Z ELECTRICAL / CD I LIGHT 8/5/22 m CONT LS CONNECTION CO I POOL IN CONDUIT ? 0 � Rm "" RED vHr GRADE EL.= +26' Z O I I SPLIT LEVEL J 0 ' ELECTRIC I N -� FRAME HOUSE I METER I 890 ARROWHEAD LANE Lq 5 BEDROOM >w ENABLE m. BROWN LOAM OL o n 2 STORY 9• 'm E EXISTIf�]I-E -O c 1 till, 2 11 PLC INPUT o i I (FF=28.9 ELECTRICAL I ¢ �, BILL OF MATERIALS PECON IC, NY v F- I (FF=33.1) 9'7 SERV`cE D VERRID / ITEM PIN DESCRIPTION QTY: �D 3 4 12 PLC INPUT SCTM# 1000-098.00-02.00-1 )06.001 3.0' BROWN SILT ML Q I I / I ; o T; CSR \ "'- W-W' "r W-WF,TTR�-W -W.0 . w W 1 HA•180056 TANK,AN500 245 NITROGEN REDUCTION 1 �' 'L" ""'P°" 14 PLC INPUT as29.1' SERVICE D_ A 180055 TANK,AN500 245 PRETREATMENT 1 TIME DOSE T"" 17 PLC INPUT M> Z B 100118 COUPLING, 4- SCH 35 PVC SXS 1 17' BROWN FINE TO O 24001 i I // ( ( C 8 FG CONNECTING PANEL 24X19 2 "' DEMAND AREA FOR HEALTH COURSE SAND SMI _ < - _ I I- C1 160028 ADHESIVE, CARTRIDGE 1 SPRAY18 PLC INPUT \� D C2 760066 240031 SF FASTENER, 3/8-16 LX 3 3/4' AT HHCS 1 N❑TESI FLOAT SWITCH TO BE RATED 2 AMP AT 120V MINIMUM. DEPARTMENT APPROVAL S TAMP I _ 5' 1 bcnTloN of ?s' ( Wl Bl MAIN PANEL DISCONNECT MUST BE PROVIDED BY INSTALLER, W1 FXISIIN�3 Dl 200013 NUT, 3/8 -16 SS 3 OPTIC SY,TLM NEW DRYWELL , DASHED LINES INDICATE ITEMS NOT CONTAIN IN THE PANEL, NO WATER ENCOUNTERED 4 OB \ D2 200006 WASHER, 3/8-16 SS E FOR LOWER REQUIRED TORQUE FOR TERMINAL BLOCK SCREWS IS 16 In-lbs: HEGW-ELEV. 2.0' BE U PATIO(8x4) ( � D3 200034 WASHER, SS 3/8' L❑CKWASHER 1 FIELD WIRING MUST BE A MINIMUM OF 60"C COPPER WIRE. ENGINEERS CERTIFICATION REQUIRED E 100110 ASSEMBLY,RE-CIRCULATION 245 COMPLETE 1 CHANGES TOLERANCES DRAWN BY DATE SUBMIT P.E. OR R.A. CERTIFICATION \ F AP600-P AP600 ATU W/PLATFORM COMPLETE 1 DECIMALS G BARRICK 11/3/16 TIC, G EC50-30-L100-PLC EC50-30-L•100-PLC1 -: MATERIAL SPECIFICATIONI FOR INSTALLATION AND CONSTRUCTION FRACTIONAL I I IIA OWTS .--&Crl H 100023 PIPE, 4' PVC SCH35 (1) 16' LONG X/X-kV64 � OF ?g SEPTIC PRODUCTS INC ANGLES AS NOTED ' I 100023 PIPE, 4 PVC SCH35 (1) 28 LONG x--*„e.I, I FOR FINAL APPROVAL. USE FORM WWM-073. O J 180111 TEE, STRAIGHT 4' SCH35 1 K 100023 PIPE, 4' PVC SCH35 (1) 10' LONG 0 '�N I V •A.-tiolf AN500 245 NITR❑GEN REDUCTI❑N SYSTEM DRAWN 915 A.DAN8 Abandonment of the existing sanitary system must be in conformance with the De artment s re uirements. SUFFOLK COUNTY DEPARTMENT OF I'IEALTH RVICES O0.4'E I h dlAPPROVED BY, SIGNATURE �� 06/03/14 R�007 HA-180056 p ' DRAWN BY: JF/JP y-. PERMIT FOR APPROVAL OF CONSTRUCTION -OR A • I Submit completed form WWM-0$O as proof SINGI..F: FAMILY RI SIDENCE ONLY I I I • I Lot 35 SANITARY SYSTEM DESIGN I � I DATE 2/7/2023 EE R-22 <_'227 JANUARY 2 2023 rt'��°-,.�"�` FEN \\ APPROVED 5 BEDROOMS x 110gpd/Bedroom = 550gpd APPROVED MAXIMUM of 5 g r,R )MIS- -_ SCALE: AS NOTED EL=24.6 0.2'E SUBDIVISION MAP: ARROWHEAD COVE A/1 HYDROACTION AN500 = 550gpd FOR EL=22.9 � C ¢'7, FILED: JUNE 20, 1963 FILE # 3810 EXPIRES THREE YEAFZ !`RC7MDATE OFA[ 'RovAL SHEET NO: S88°42'20W ` � J 135.00 LEACHING: Lot 34 THERE ARE NO SURFACE WATERS WITHIN 300 FEET 5-6 BEDROOMS PLAN (Dwelling - Public Water) [2] LEACHING POOLS 8' DIA x 8' DEEP SITE ALL HOMES WITHIN 150 FEET OF PROPERTY CONNECTED [1 ] EXPANSION POOL 8' DIA x 8' DEEP SCALE: 1" = 30' TO PUBLIC WATER Ci ARCHITEC rS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL INALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S E E L M A N 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL 25235 MAIN ROAD INTEGRITY UTCHOGUE,NY 11935 EXISTING WALL RA: NEW WALL j�cK DUPLEX RECEPTACLE OUTLET ED ARC-�\��BEANS 220V RECEPTACLE OUTLET QUADRAPLEX RECEPTACLE OUTLETG� Illp HALF HOT RECEPTACLE OUTLET — J WP WATER PROOF RECEPTACLE OUTLET ,,ryrye� i ., rntyo GFI GROUND FAULT INTERRUPTOR OUTLET I REMOVE EXISTING STAIR / AND PARTIAL WALL ` �r�04 CN PATIO 436 H-i HIGH HAT FIXTURE _ I l \ OF NEIN SURFACE MOUNTED CEILING FIXTURE --._ - OWNER: I--�- SURFACE MOUNTED WALL FIXTURE j I I �� T—� Tin- -7-1 1 SURFACE MOUNTED SPOT LIGHT LDNIEXISTING� LINDSEY< VD KEVIN KING PATIO SWITCH — --�/ I I I 131 MAPLE STREET I I I I BROOKLYI ', 11225 D SWITCH DIMMER I ly I I I I IREMOVE EXISTING DECK—/ PATIO RETAINING WALL-J i � AND STRUCTURE ABOVE TO REMAIN PH TELEPHONE -L�� REVISION.' 0 TELEVISION — — 3'-2" SMOKE DETECTOR I BIDDING G DAFT 11.4.22 S/D CM CARBON MONOXIDE DETECTOR I I I — DOB FILIN I 11.30.22 DOB REVI: ION 1.19.23 X SURFACE MOUNTED CEILING FAN I I I I I EXIST. ( � 11'-3" 12'-5" BID SET 1.26.23 EX/F EXHAUST FAN MECH ICLOSET PERMIT St T 2.07.23 F SURFACE MOUNTED FLORESCENT FIXTURE — 7 JKEEP OIL TANK-J 100 UNDER CAE3INET MOUNTED FLORESCENT FIXTURE FOR FUTURE USE EXISTING I FAMILY RM EXISTING � T SURFACE MOUNTED LIGHTING TRACK � BEDROOM EXTERIOR WALL MOUNTED FLOOD LIGHT II EX/F EXHAUST FAN EXISTING KEEP WATER TANK PC SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN I GARAGE FOR FUTURE USE REMOVE ALL CEILING TILE REMOVE HVAC SYSTE REMOVE ALL CARPET—/ EXIST. EXIST. VL CLOSET CLOSET NFIREPLACE STRUCTURE ABOV REMOVE ALL DOOR TO REMAI O 12'-5" EXISTING RE AOVE ALL GARAGE DOORS— BEDROOM �t n up n I I o U U I Z I- - -STAIR EXIST. I W REMOVE ALL TRIM/CASINGS AND I TO REMAIN. BATH WINDOWS 1HOUGHOUT fREMDVE CAAPEr — — — Q I- - - - - u 21'-7 1/4" W 11'-3 114" 12'-5" EXIST. C( Z ENTRY ABOVE (DV Z Z O U CL FIRST FLOOR DEMO PLAN PROJECT, IDDRESS: 890 ARROI /HEAD LN SCALE: 114"=f-0" PECONIC I 'Y 11958 DRAWN B` DATE: 1.2.r 23 SCALE. DRAWING SHEET NAME: 1ST I =LR DEMD PLANS DRAWING SHEET NO: ARCHITEC rS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S f � M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S E E L M A N 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL 25235 MAIN ROAD INTEGRITY CUTCHOGUE,NY 11935 EXISTING WALL RA: NEW WALL ED A / JEA DUPLEX RECEPTACLE OUTLET �Cy � � T 220V RECEPTACLE OUTLETS ����� NS-9,��c� QUADRAPLEX RECEPTACLE OUTLET AG HALF HOT RECEPTACLE OUTLET — WP WATER PROOF RECEPTACLE OUTLET �� —\� ♦` • , GFI GROUND FAULT INTERRUPTOR OUTLET I I H HIGH HAT FIXTURE I ( ,T,9T 04436 L OF NEIN SURFACE MOUNTED CEILING FIXTURE OWNER: SURFACE MOUNTED WALL FIXTURE T-I -j' (-T SURFACE (MOUNTED SPOT LIGHT L/NDSEYL' VD KEVIN KING I I I I I SWITCH �' — I �.� I I REMOVE EXISTING DECK—/ EXISTING 131 MAPLE STREET I I - AND STRUCTURE DECK BROOKLYI ', 11225 $D SWITCH DIMMER I I I I� I IDN 15-0 1/2'' PH TELEPHONE ---.L L� � 21-11 1/2 12'-3" ' REVISION: TV TELEVISION j S/D SMOKE DETECTOR j _ _ BIDDING E RAFT 11.4.22 CM CARBON MONOXIDE DETECTOR _ — — — — — — — — — — — — DOB FILIN' f 11.30.22 IT X SURFACE MOUNTED CEILING FAN I I I I I I ( T I [' T DOB REV(: ION 1.19.23 REMOVE EXISTING WINDO+� J I I / I I I I 4 BID SET 1.26.23 EX/F EXHAUST F=AN I I I I I I N N I I I I I I I I PERMIT St T 2.07.23 C EXISTING EMOV LOW USS COq� F SURFACE MOUNTED FLORESCENT FIXTURE I I I I I I I I I I I I �NSTREURCTRAL I �' I I I I I I I KITCHEN MAINTA UNDER CABINET MOUNTED FLORESCENT FIXTURE INTEGRBY SHING T SURFACE MOUNTED LIGHTING TRACK I ( I I I I I II II II I � I��� I I EXTERIOR WALL MOUNTED FLOOD LIGHT I I I I I "1 '1 ' I I I I I I I I I III I REMOVE ROOF JOISTS �I ` t I I I I I AS NEEDED FOR SKYLIGHT I I �`= J � EX/F EXHAUSTFAN ' I I I I I I I IEXIS ING Pc SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN I I I I I I I ( I �EDROM EMOVE ALL-TILEXABINETRY, - I I I REMOVE ALL-DUCT ND ENTS I I COUNTERS,APPLIANCES WALLI FRIF I ( ( ( ( I ( I I I EXIST NG i � � \� � OVEN tV LIVIN ROOM _ _ — - L L - - - - - - - -ll-- - OO - �I- - - - - - - - N - - - - - - - -1-I--- - - - - - fi-I- - - - - - - -I-fi - - - - - - EXIST. PANTRY EXIS . K�\ \ LAUNDRY EMOVE LL CAR14AFINISHESIl ��, I REMOVE CEILIN — -- I XT � I I I I I I REMOVE CEILIN ( II I I " I II II II -1 co I r --REMOVE WINDOW. ui I I I I I I I �0 1 EXIST. CHECK ELEVATION BATH v DON ims.EW WINDOW U \1 v o I I I I I I DNI I 1 ��._ _� 410. I I I I I I - -� J \ I EXIST. I I i t I I I EXIT �_ I CLOSET W ATH I I BI I Zo 0 a � DN g' 10'-5 3/4" 7'-3" EXIST. I Z I ENTRY II I II I I I I I I I (D I Z o EXIST. Ti— W� TI CLOSET 3- 8 10 1/2" I E�IOVE STEPS AND HARD tE '- - I L I � — PROJECT.'DDRESS: J .J 890 ARROI /HEAD LN PECONIC I 'Y 11958 SECOND FLOOR DEMO PLAN SCALE. 114"=V-0" DRAWN Bl, - DATE. 1.2. 23 SCALE: DRAWING SHEET NAME: 2ND FLR DEM D PLANS DRAWING SHEET NO: It 0 ARCHITEC TS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. SM U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. cc 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL S E25235MAI ROADM A N INTEGRITY CUTCHOGUE,NY 11935 EXISTING WALL RA: NEW WALL DUPLEX RECEPTACLE OUTLET �ED RC EAN 220V RECEPTACLE OUTLET 4'-71/2' 2'-101/2" 7-4- T-61/2" QUADRAPLEX RECEPTACLE OUTLET j ` Gfi HALF HOT RECEPTACLE OUTLET g ' f f• * \ ` t owp WATER PROOF RECEPTACLE OUTLET ('I)GFI GROUND FAULT INTERRUPTOR OUTLET j := W, HIGH HAT FIXTURE M ,TqT 04436 O `� I I I I F � ¢ OF NEW - - SURFACE MOUNTED CEILING FIXTURE I ' # f • ' I I - OWNER: XT.SONOTUBES SURFACE MOUNTED WALL FIXTURE I I RAIN TO DRY WELL W/4X4 PT POST W/ SURFACE MOUNTED SPOT LIGHT j � I SMRPRSOPN�P GALV. 2 / I LINDSEYI VD KEVIN KING Lo SWITCHEW SONOTUB�S I 1 131 MAPLE STREET STRUCTURE ISTING RETAINING WALL BROOKLYV, 11225 $D SWITCH DIMMER 4" 9'-61/2" ' FOR DECK ABOVE PH TELEPHONE REvrsroN: TV TELEVISION N BIDDING G ?AFT 11.4.22 FS/–Dl SMOKE DETECTOR —) CM CARBON MONOXIDE DETECTOR 00 0 01 0 �o DOB FILIN' � 11.30.22 SURFACE MOUNTED CEILING FAN DOB REVR ION 1.19.23 � EXHAUST FAN I � BID SET 1.26.23 EX/F I I I(STING FOUNDATION WALL R /T I PEM SE T 2,07.23 ( I F SURFACE MOUNTED FLORESCENT FIXTURE RAIN TO DRY WELL I I UNDER CAE3INET MOUNTED FLORESCENT FIXTURE I I I I'� o T SURFACE MOUNTED LIGHTING TRACK °' I I, — — — EXTERIOR WALL MOUNTED FLOOD LIGHT , \ I I I IzQl EwF EXHAUST FAN ►- EW FLOOR STRUCTURE w PC SURFACE POOUNTED CEILING FIXTURE w/ PULL CHAIN I/ ON EXISTING 4"SLAB. �x O EW RETAINING WALL \ I N SPRAY FOAM INSULATION x c� LLl I� XISTING FLOOR JOIST v_- \ I BETWEEN FLOOR JOISTS. SP EXISTING SLAB.NEWS • ___- -- _--—_-------__--.-------- --_-_--- —- _- —,' SPRAY FOAM INSULATION PE co I 1'8' I SPEC. f 6'.0" PITCH CONCRET TO DRAIN I. EXI 1NG (3) 10" EXIS ING GIRDER(3)2x1 "C.8 I N ih O— -- 1 EXISTING GARAG DOOR OPENS/ I r / I "WX10"HX4"dp EW STS LL P S S A D ` BEAM POCKET EXISTING (STING 31 STEEL COLUMN / I -OO'll'G F OTIN ON 24"X 24.12"CONC.PAD LL 1 U XISTING STRUCTURE I FOR MASORY ^ 8"THICK POURE 1 STING AG GRAI FIREPLACE o CONC RETAINING WALL. I SEE DETAIL I , DOOR OPENING I ! N z TX 5'X 12"EXISTING z CONC PAD C Z RAIN TO DRY WELL I I I W I I I I cr z II II � z II II II Ir--EXISTING FOUNDATION WALL z o FOENTRYWAY ABOVE U 1 , ' L_ J PROJECT, ,DDRESS: 890 ARROI /HEAD LN PECONIC I 'Y 11958 BASEMENT CONSTRUCTION PLAN SCALE. 1 /4"=I�-O" DRAWN B`, DATE. 1.2, 23 SCALE. DRAWING SHEET NAME: BASF :MENT CONC. PLASS DRAWING SHEET NO: r 'g ARCHI TEC 'S: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER, 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL S E E L M A N 25235 MAIN ROAD INTEGRITY 3 4 CUTCHOGUE,NY 11935 7 E=XISTING WALL RA: NEW WALL EV!MAHOGANY STAIR TREADS �-- �ERED A& C� DUPLEX RECEPTACLE OUTLET 23'-6" ,y 5 E JEA/v �T 220V RECEPTACLE OUTLET 4'-71/2" 18'-101/2" ¢�c ���¢`� 5��0 r Gtr QUADRAPLEX RECEPTACLE OUTLET HALF HOT RECEPTACLE OUTLET (PWP WATER PROOF RECEPTACLE OUTLET j � EW METAL AND WIRE qGF' GROUND FAULT 1NTERRUPTOR OUTLET RAILING.SE SPEC EY HIGH HAT FIXTURE T�9T 04436 SOF NEW EW MAHOGADECK SURFACE MOUNTED CEILING FIXTURE OWNER: SURFACE MOUNTED WALL FIXTURE SURFACE MOUNTED SPOT LIGHT DECK I N 2 LINDSEY/ dD KEVIN KING SWITCH 131 MAPLE STREET Dh BROOKLYI '. 11225 D SWITCH DIMMER 21'-6" ; 11'-5 1/2" 15'-0" 8'-11112" 1-61 5-81/2" 11/2PH TELEPHONE 11" 4'-11/2" 4'-41/2" 5'-10" 4'-91/2" UILD TELEVISION OUT GYP REVISION: TV , BOARd WALL M BIDDING E ;AFT 11.4.22 OD S/D SMOKE DETECTOR D D H H D D CM CARBON MONOXIDE DETECTOR ` - - - - - - - - - - - - - - - - - -2Xt� - - - - - D08FILlN 11.30.2 2 SURFACE MOUNTED CEILING FAN — .-,—.-NEW WINDOWS DOB REVI, SON 1.19,23 = I NEW CATHEDRAL N _ CABINET I BID SET 1.26.23 E I CORNER EX F EXHAUST FAN N I —I- CEILINGCABINET I PERMIT Sl T 2.07.23 o DRAWERS F SURFACE MOUNTED FLORESCENT FIXTURE I EW SKYLIGHT UNDER CABINET MOUNTED FLORESCENT FIXTURE NI I SEE ROOF PLAN E I bo ICRowAVE A g DRAWERS a i PERMIT SE T-REVISED 2.27.23 T SURFACE MOUNTED LIGHTING TRACK N I I RAWERL_Ib� N 1110 z z~ EXTERIOR WALL MOUNTED FLOOD LIGHT T � DRAWERS n I 'G EW WHITE OAK EX/F EXHAUST FAN ooRl GTHOUGHOUT PC SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAINo NEW WHITE OAK / M BEDROOM BUILD OU. GY CORING THOUGHOUT iv EN 205 ....................... BOARD WALL I KI 206DRAWERS co T-10" Y-191" 2'_1" NEW POST I --iJ W WINDOWS DOOR SCHEDULE NEW TILE --- - -.......-. � 1----- -- ---.._..----___...---------------- TIATFIREPLACE —— - 2 I = DOOR# WIDTH HEIGHT MANU NUMBER PANEL HARDWARE TYPE \,,5 D1 ; 2'-10" 6'-8" FLAT L-LOCK, - N 36"FRIDGE P-PASSAGE 3.2X10 ' 04 1 H- 1 HR RATED °' SOLID OAK ■ Icw N NTEL PIECE N D-DUMMY - EH� - D2 FLAT L-LOCK, co _. . . CL_ 2, 8„ I 6'-8" I P-PASSAGE — N �' I 1 H- 1 HR RATED 3'0" 6'-2" I "'-, __-----.___-_-- o � D-DUMMY MNG ROOM CL � -D3 .. . 2'-6" 6'-8' FLAT L-LOCK, 202 _ - c 8'-11 1/2" o ------- - ------ - - --- - _ - ---- P-PASSAGE — v, 3 - - D4 ( j FLAT L-LOCK, 1'-2" -�. v' 403 M _. 2'-4" 6' 8" UILD OUT GYP `' ._ -PASSAGE BOARD WALL 1 " NEW WINDOWS ;.. _..._.._..__..._ METAL RAILING WIT o f FLAT --E-LOCK, PICK AND HEIGHT PER CODE. 40f HALLWAY -~\ Lo 2%0" 6-8" P-PASSAGE HANDRAIL SOILD OAK STAINED TO F 201 M BATH I ' I ' --'--- ----- -------- -- .. _... _ 1. .__._. ----r-- D-DUMMY N I MATCH FLOORING - - - - f XISTING I L ( iii _._. -- 204 D6 1 -0" 6' 8" i FLAT L-LOCK, E 403 SKYLIG P-PASSAGE TIN LL EW TILE F1 CORING a V D7 5'-0" ! 6'-8" ! SLIDING CL DUMMY iv WOOD (LING NEW SOLID OAK l P BATH I �, STAIR TREADS ' _.._.....�....._........ \ STAINED TO MATCH D XISTING N _........_..__. NEW WINDOWS N SKYLIGHT EW MILLWORK ED1 3-0" 6'-8" I ELIFD 36"X 80" GLASS SWING KEY LOCK iv c�71 FLOORING I ' DESK I o BOARD WALL X-LHI DEADBOLT 17 I ED2 - 5'-9 1/2"--^ _. ._6 8 �ELSPD 69"X,80"XO 2 PANEL GLASS KEY LOCK E ui NiG o SLIDING 1�1_ o o N E63 5'-81/2" 6'-8" i. III ELIFD 69'"X 80" FRENCH GLASS KEY XX-LHI LOCK/DEADBOLT ED4 3-0" 6'-8" i ELIFD 3068 X-LHI !---SINGLE SWING KEY LOCK D ODD b DN ED5 11 -11 1/2"j 6'-8" ELSPD 12068 OXXO; SLIDE 4 PANEL KEY LOCK C O 17,7" 4 0 3 6 1/2 " Z T 1" 1'- " 4'-2" '-5 1/2 - - WINDOW SCHEDULE _ __ s V-71/2" 9'-01/2" WINDOW TAG WIDTH R.O. j HEIGHT R.O. MANU TAG TYPE MANU = -- _ -- ' _ - - -- ENTRY I U L___ _ -- - - FRENCH MARVIN 200 I ® " UP _..__ C _. - C.� ...._...._........._.._.-_A _...__.i._._..._.__.2 8 _._. ..__ 3' 5" ELCF 16"X 41"2 LR CASEMENT -_ -- NEwwINDow rn N a z B 7'-8" f 6'-2" FIXED MARVIN ELDG 3 74 O ,X I C V-6" 6'-2" ELDG 18"X 74" FIXED MARVIN TEMPERTED EwSTONE STEPS ` AND RAILING �( D T-0" 5'-10" ELDG 36" X 74" FIXED MARVIN i I TEMPERED _._._._.. q 2-2xIo D2 3'-0" ( 5'-10" ELDG 36"X 74" CASEMENT MARVIN TEMPERED 3'-0" E 2'-8" 5' ELCA 32' X 6b" CASEMENT MARVIN NEW POST j -b" - PROJECT. ESS, 2'-0" 3'-6" ELCA 24"X 43CASEMENT MARVIN __...._. 890 ARROI, 1HEAD LN \------N G 3'-0" 4'-0" ELCA 18"X 48" CASEMENT MARVINEW WINDOWS PECONIC t Y 11958 H 2'-2" T-2" ELCA 26"X-38"" CASEMENT MARVIN ! J 2'-10" 6'-8" ELDG 34 2"X 80" SIDELIGHT ....._.. _. -MARVIN- _ TEMPERED - _____- 2ND FLR CONSTRUCTION PLAN - - -_K - - ---- I - --�-9" - 3'-5" XXX - ( ' SKYLIGHT VELOX DRAWN B' . L._._._.._.._.....___ ...__. i ... ........_...._2'-$ 3-8" ELCA 32"X 44" CASEMENT MARVIN 14"=V-0" 4��^1 Ori -_ DATE 1.2,' 23 SCALE: DRAWING SHEET NAME: SECOND FLOOR PLANS DRAWING SHEET NO: 0 0 0 W I� ARCHITEC -S: NOTES —1. EXISTING DIMENSIONS SHOWN W PLAN TO BE CONFIRMED!. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW 131ZES BEFORE PLACING ORDER. i 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL E E L M A N S INTEGRITY 3 4 TCH MAIN ROAD CUTCHOGUE,NY 11935 EXISTING WALL EW STAIRS IN DECK EUSE EXISTING POSTS AND FOOTINGS.REPAIR AN MAGE AND DISCUSS WITH RA: AP•CHITECT PRIOR 10'-7 1/2" NEW WALL 23'-3" 3'- ED - R�EAN�� DUPLEX RECEPTACLE OUTLET �y�NE 220V RECEPTACLE_ OUTLET EW CEDAR SLAT DOORS QUADRAPLEX RECEPTACLE OUTLET u PER ELEVATION HALF HOT RECEPTACLE OUTLET .._ 3-2X8 TR. WD. -COPING STONE WITH RAILING WP WATER PROOF RECEPTACLE OUTLET N UP ON TOP OF EXISTING PATIO GFI GROUND FAULT INTERRUPTOR OUTLET o EXTERIOR RETAINING WALLS LW, HIGH HAT FIXTURE r GE F-XAX M ,r 04436 3-2X8 TR. WD. IN O DR WELL �rFof N�N'�° IS SURFACE MOUNTED CEILING FIXTURE - — -- - OWNER: I- - SURFACE MOUNTED WALL FIXTURE s — — — PAVER r N N PEDESTALS PATIO { SURFACE MOUNTED SPOT LIGHT N N II EWP09TS I —XV ( -- iv — AND FOCTINGS ( 2 LINDSEYf VD KEVIN KING SWITCH "' — — — ' ? PITCR 131 MAPLE STREET $ I F o { BROOKLYI 11225 TO AREA DRAIN $D SWITCH DIMMER _...._... _...... i N 12,_5" 2X8 TR.WD. LEDGER W/14" PH TELEPHONE TIMBERLOCK CIC 8'-8 T-6 /2" T-11/2" 5'-9" STAG ER TOP18+"BOT O f1 n 3-5" TV TELEVISION s'_1oN 4 $'_ 1" 1 1/2" a'-9" _ T-0"_ REVISION, , S/D SMOKE DETECTOR G BIDDING E RAFT 11,4.22 CM CARBON MONOXIDE DETECTOR _. ........_..-2X..__. __..__ 7 ---- DOB FlUN : 11.30.22 OPING STONE WIT RAILIN _ _ _ VEN TO TERI L DOB REM' ION 1.19.23 SURFACE MOUNTED CEILING FAN - - — — ME H tt EXlF EXHAUST FAN r — W s M OIL TANK OIL FURNCE M 108 401 8!D SET 1.26.23 PERMIT SI T 2.07.23 F SURFACE MOUNTED FLORESCENT FIXTURE H 1H D WASH J UNDER CABINET MOUNTED FLORESCENT FIXTURE "" RAIN TO DRY WELL / PERMIT SI T-REVISED 2.27.23 T SURFACE MOUNTED LIGHTING TRACK LA 11DRY _ = N RELOCATED ELEC PANEL q BEDROOM 1 `- I AIL 15'-1o" _ 21"C>S N 103 .- EXTERIOR WALL MOUNTED FLOOD LIGHT EX/F EXHAUST FAN N � GYM 21"CAB pC SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN . . NE FLOORIN 107 / I FAMILY ROOM ON NEW 2 10"FLR JTS 101 . .......................... ..................................... ...... a PAVER NEW POSTS AND--� < 30"FRIDGE I ON IRM EXISTII POST AND _..._..._-_.... ON PEDESTALS FOOTING. PROVIDE ACCESS - PITC \ O IN DOOR SCHEDULE TO AREA DRAIN PAM INMECHSPACE. ..........................._...............,...................._......._.._.._..._......,.......,......................... ...,..,..,....,......,._„ ......,,..........,. ................... •_......._.._....-_... PITC { DOOR# 1 WIDTH HEIGHT MANU NUti1BER PANEL j HARDWARE TYPE "'' _ to _..._. _..._._._.._..__..___._. .._.._.....__...._._.._.......__.._..._..__..___-._._.._._. ECHANIC • - 3'-PIN MECHANICAL D1 2'-10" 6'-8" FLAT L-LOCK, N E N �, P-PASSAGE N M zmm= UP PATIO m ' 1 R RATED - � ----- DUMMYE __.._-._.._......._...._.__e.........._........_.._.__....... ..................._.......... ._.... ............ { ........ . _......._......._. _._...... _.._.. HALL N 11'-9" N ........_....... ._....... ._._ FLAT L-LOCK, COHEIR COHEIR P-PASSAGE Foonrlc POSTAND D2 j � EXISTIN EXISTING 1H 1HR RATED 110 { D=DUMMY 1/2" FOOTING. -5 D3 FLAT — L-LOCK, 2'-6" 6'-8" ,." PASSAG NEW FLOORIN _........... .... ....._...._._ ...-._..._....._....._......_.. ..._. .. _ —... ---- - --.._. _.._. P-PASSAGE D4 FLAT L-LOCK, o ON NEW BEDROOM 2 �.-4 6-8" �4tO2 P-PASSAGE N �:, EXT FLR JTS D5 - - FLAT L-LOCK, rn 6'-8" P-PASSAGE �, ` / � Mui -----D-DUMMY �' UP BEDROOM 3 ° 6'-8" 106 D6 FLAT L-LOCK, ----------- _._--------_... P-PASSAGE 0 NEW FL ORIN BATHROOM . P BATHROOM kol E�-0" 6'-8" SLIDING CL DUMMY -1 105ON EXT LRJTs LINEN Cl ED1 3'-0" 6'-8" ! ELIFD 36" X 80" GLASS SWING KEY LOCKCD X-LHI DEADBOLTto A _... _.....__._....._ I .__. I ..... ...... i..... .-... _ ...-.. RAlN..701)EY 4YELL ED2 5'-•3 1/2" 6'-8" IELSPD 69" X 80"XOi 2 PANEL GLASS KEY LOCKccco N • ED3 5 _._. ELIFD 69 2 X 80 _ SLIDING 8'-10" FRENCH GLASS KEY XX-LFI LOCK/DEADBOLT — - ED4 j 3'-0" 6'-8" i ELIFD 3068 X-LHI SINGLE SWING KEY LOCK v� } .. — 3'-5ui 1/2" 5'-3" ;' » ED5 11'-11 1/2" 6'-8" 'ELSPD 12068 OXXO SLIDE 4 PANEL KEY LOCK 7-3" ( ( -2 6'-2" 4'-101/2" EW DOOR 1 N : _. .,..,... . .. i F -� 11'-6 1/2" 5'-4" 11'-5 "'• 12'-5" z WINDOW SCHEDULE WINDOW TAG WID-fH R.O. HEIGHT R.O. I P�,1ANU TAG TYPE MANU _ 49'-T 1 U A 2'-8" 3'-5" !ELC,A 16"X 1"2-LR FRENCH MARVIN � z --- -------- ---- - -- CASEMENT B 7'-8" 6'-2" ELDG 30,' X 74 FIXED MARVIN _— EXISTING CRAWL Y C 1'-6" 6'-2" ELDG 18"X 74" FIXED MARVIN SPACE UNDER ENTRY TEMPERTED ---- - ...._...-..........._...... -_..__._... _......------ — -- D -0" -10" ELDG 36" X 74" FIXED MARVIN -• ;:' TEMPERED ,s,,.. ,.;_.;..,•. EWBFORSTAIRSABOFOUNDATION •�, .a �' ;a,.;;.� •.;+?1'.:+. ;.,' WALL FOR STAIRS ABOVE D2 j -0" 10" ELDG 36" X-74" CASEMENT MARVIN _......_.... ..._...._._._...._....._..__..__......... _......_.__._..............._....._...._.... ._.._....._.... . i _._..._TEMPERED _.. - - -- ---- _............._.... -- - - T-7" E 2"-8" ELCA 32"X 60" CASEMENT MARVIN 5'-0" ; PROJECT, DDRESS: : F 2''-0" 3'-6" ELG•A 24"X 43 CASEMENT MARVIN 890 ARROI /HEAD LN G 0" 4'-0" ELCA 18"X 48" I CASEMENT MARVIN PECONIC t Y 11958 3'- H 2''-2" 3'-2" j ELCA 26" X 38" CASEMENT fi MARVIN --_ _--- - __ - LI I T FLR ------ ------- -______- -_______ S CONSTRUCTION PLAN J ' 2'-10" 6'-8" ELDG 34�'"X 80" SIDELIGHT MARVIN 1_-_-, TEMPERED-__ ---.__-- . DRAWN B` j K 1'-9" 3'-5" XXX j SKYLIGHT VELOX _ ►�_ , a1 . ...._...__...._......_..-----._._..._. _ SCALE: 114 — Q DATE: 1.2! ?3 L 2;-8" 31-81,_— 1 ELCA 32."X 441, CASEMENT MARVIN SCALE: DRAWING SHEET NAME: FIRST" FLOOR PLANS DRAWING SHEET NO: ARCHITEG r-S: NOTES 7. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S it M U E L S & • 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. i IS E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 EXISTING WALL NEW WALL RA: Q DUPLEX RECEPTACLE OUTLET 220V RECEPTACLE OUTLET ! !,��RED Ape O//� N� 7� # QUADRAPLEX RECEPTACLE OUTLET J JEAN ALF HOT RECEPTACLE OUTLET � ��'�� S�G�� H y � I. �, * 0 WATER PROOF RECEPTACLE OUTLET ' [��,GFI GROUND FAULT INTERRUPTOR OUTLET UP 4 RV, HIGH HAT FIXTURE . 0��IT x4436 OQ�" FOF NEWS + SURFACE MOUNTED CEILING FIXTURE I + SURFACE MOUNTED WALL FIXTURE I SURFACE MOUNTED SPOT LIGHT : OWNER: I- — — ——I ,...- . . ;.... _. ....... .............. ..... } SWITCH — --I : LINDSEY1' VD KEVIN KING o SWITCH DIMMER I– — — — –{ 131 MAPLE STREET i BROOKLYI 11225 PH TELEPHONE _ — J TV TELEVISION UNDERCABINET LE D---\ REVISION: SID SMOKE DETECTOR BIDDING G ?AFT 11.4.22 CM CARBON MONOXIDE DETECTOR I (P"P — — `" — ,. ::..:, ,. — - - 1 — r .. :. , . .._ . . : 1 MOUNTED CEILING FAN ,. ' . ... SURFACE MOU G A ,:. . : . .:. . ,.. ...;,...: .. ... .... . . .. . . ... ION _..... .......... _ : t EX/F EXHAUST FAN r , �� 0 .,,4 a 3 .:: - "yam. ''•"`•:.>. BID SET 1.26.23 i 11 r`_ F F E M NTED FLORE ENT IXT E N' SUR AC OU SC F UR �. ,: MA1. ,.i Ci X S#IN :£ MAE�:': :Y.. f 11 T PERMIT E �. S 2.07.23 UNDER CABINET MOUNTED FLORESCENT FIXTURE • .. 4 �S` S U ✓. J.:. 1 :; ,• 'r J:' ,:.: T NT D LIGHTIN RA •'; -.: , :.;.: S RFACE MOU E G T CK ::�.: :r. f: ai { .:". :: °; :'.;:: •:; .r _ _ WALL MOUNTED D T �; t, ­ EXTERIORFLOG LIGHT / �1; — /'•:'' :, ` b : ':;'.. 4.66 . ': :,,:• \'t`• 1. Y, is 7,: ;.,$.©: b G A f f P % '�:' ;: . .1:. PJ EXHAUST A : : , S F :;.: i" Ti ' ' ' :>.. :'." CD :S' o ,�,::. .f. .. :.\. FA E MOUNTED CEILING FIXTURE SUR C MC w PUL A :. Y': {• •r,' t. PC ; . :� ; ; : ,. ,:: :i: t' :� �, ::,, :';.': ::�: •t: ::;r �• .;l, `; % `' .,�.. `::.: :: p;. �" `« ,' 1.1, A. .` ',; 'Jt '. ••:..'• ✓4 t. Y' t,:.' �h~ L i.t, y\ A: *: I: ,tt'. .P'r r," .I , J�T• `'\ ',I I t:r J i kRR.11:. i ', ;P B ..";' � .. •i•:sI''G�t •' . \ _ .--� . . r' :.r•: � �<'" nr ;• v.1.�' j: ,, t _ J,^ �. `f ::J r l` i ., .... ........ .. ... .. .. ......, ,�ti.. k. �'.. 4. I "1'• I.. :. ..X. _ r 4�1„ ,r1.. UP % :a �... ; " :YI :.�: :,..: :5 b` f';;^. 5" r r� :• : •' ... r , r� r.4•' 1 't~ ' .I•r.. -' _ W. _ S 7...'. t V'. h'yi + :\. ' ` +' �+ : + ��d •'/... 4. �.1.r { y ,,+ sl {{ \; : `. ; .: C .. s i . . `; ,� ,..,4-%.,:;.t: , :t": ' . ... :: ,... .. .. . ,.. ... _.,..:. :.f.: , '. ,: :: ....,. : , ..., .... ": o> \ ;.1. : .. .,........,...... r . ..,.. p :;, < ..,.. .. .. .. ..r ^�,. ., <. ...; ,•. :, . .. . .. r,... .+ _ . t' -L :.... ..n 7..., �..Y .. I J J �.,, 1 �. "i: j :.y:'• * " orf �:',. .\ ` �J. }_ '. j 1 : '.: i.ti N: .; j 1 — , v:. ./� ..:. .,,...":. .. ,. "...::... ,ti. "I 2•: t / Ub W .7',9"'GX 60 A..2 : ::.; :' I . ; ti 1„ <I:. :;': ,} , , , () :.ti. - • v :. II'. ,•1''' i I. �: ^'t 1' v. l :x.i ..stn — •: �Jtr'T .< : µ ' : J: t `L ;; . ; :`."' ''. it. Ex .'I'1iYl, ��a '' cvfay s. 9. R :�. 1. ... .,:%.-,�, ,�,�:�­.-��..'. .,� z Q .,, '::r•'.; u. 'I�hA G::;':'.;:. if`' `LW L yJ. — — — — .1. y W �. ; , 4. 1 1. !'i 333 ;I'H a. — : :. . '. -,.%:%-: .�.:, " . 1, : .. . .. , .. . .. --..I--,—�.... 0 b::,.. �� GFI y'. . . :.,..r.....: .. ... :... — — — — , :,':: 1 I I I I— .,jY. ___ _ v 1... t 1.*I:N .. I ,'7 I I I I '`-t :.. � . . ,, ()� z •. I I I I _; U 't -�- I I I I 4.: ,': "..w. I ( :, (D -T' Z ':".1 .... .,..-.- �.... I I I I °: Z O .. I'# I. .. .. . ,. I I I `: ._ U -IW*: .. . .... . . I I I I I.v; � W ;.% I- . .. ....... ''{•' 0— .! .......I ... 1-. ,: 'f, <. 'fI - ' ,�. PROJECT, 0DRESS: 890 ARROI /HEAD LN IST FL R EL EC PLAN PECONIC I 'Y 11958 SCALE. 1 /4"=1'-0" DRAWN B; - . DATE: 1.2f 23 SCALE: DRAWING SHEET NAME; FIRS r RCP/ ELEC PLAI` IS DRAWING SHEET NO: ow . I 1*012, () 0 ARCHI TEG '`S: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. j S /► M U E L S & S E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 EXISTING WALL NEW WALL RA: I DUPLEX RECEPTACLE OUTLET 220V RECEPTACLE OUTLET ��REDaRc QUADRAPLEX RECEPTACLE OUTLET _ _ — r��5 ��E JEAIVs HALF HOT RECEPTACLE OUTLET WP WATER PROOF RECEPTACLE OUTLET C3 u GFI GROUND FAULT INTERRUPTOR OUTLET I. HIGH HAT FIXTURE I T,QT 04436 Q¢�" i / FIN —�— SURFACE MOUNTED CEILING FIXTURE / I—�— SURFACE MOUNTED WALL FIXTURE 1 OWNER: I� I SURFACE MOUNTED SPOT LIGHT SWITCH I LINDSEY/ VD KEVIN KING D SWITCH DIMMER ICHTSON FISERs T i 131 MAPLE .STREET BROOKLYI ', 11225 FP HI TELEPHONE TV TELEVISION FS/7D SMOKE DETECTOR ! — \ REVISION, : CM CARBON MONOXIDE DETECTORBIDDING E SAF 11.4.22 SURFACE MOUNTED CEILING FAN ►Ni DOB FIL11.30.22; EXHAUST FAN 5' — — — — — DOB REV(: ION 1.19.23 _ / —=� EX/F _ � / IL BID SET 1.26.23 ED AT EDGE BEAM(TYP)F SURFACE MOUNTED FLORESCENT FIXTURE I I � I ISTINGRVAdUNDER CABINET MOUNTED FLORESCENT FIXTURE ISI REASEHVACDUCTSTCfREMA1N PERMIT St T 2.07.23 I I I D�CTS SIZES IF NEEDED T SURFACE MOUNTED LIGHTING TRACK EXTERIOR WALL MOUNTED FLOOD LIGHT � I ---- EX/F EXHAUST FAN �� I I �\ EILINGOPE TO SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN — \ FINISHOVE.GYPBOARD (STING PANELIN \ I L _� I L—J I TO BE RES7AINED \CK -0 \ EDROOMLIGHTING / INSTALLED ON SIDE F i I I 1 r EW VENT TO EXTERIOR 205 BEAM \ I I KITCHEN I I I 206 XISTING HVAC DUCTS TO REMAIN LL - -- _ I I� i M Ate.' / - Y.P IB I I \ 'L I OAR LIVING ROOMfAA \ L. �I:.. \ a � 202 \ , .... y k _ Lm v : ,. I I I A R __ :2 T`L' .rte' I It I Y e^nh I a. a o' • I — fl''• 'Y `M'SAT'. F�' I — I I ! _ I I I I Ai­ ---DU L : :�I'•`•:','..: N CEASE HVAC � Q L r:. DU TS SIZES IFNEEDED EDA E �..' T E)GE AM I G BE I� I L J / I W ••k. r: rAil !,-` � � I ' U / � Z I z O IGHTS ON RISERS V W ISL PROJECT, 0DRESS: 890 ARROI 1HEAD LN 2ND FLR ELEC PLAN PECONIC I 'Y 11958 SCALE: 114"=1'-0" DRAWN B DATE: 1.2,1: 23 SCALE: DRAWING SHEET NAME: 2ND FLR RCP/ ELEC PLAPIS DRAWING .SHEET NO: Orb A,1130 'm� ARCHITEG rS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED" 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. - S E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: E J E AN ; a t Cft"t0 ,T,qT 04436 'E OF NEIN OWNER: LINDSEY/ VD KEVIN KING 131 MAPLE STREET EW BLACK ROUND GUTTER BROOKLYI ', 11225 21'-10" 28'-9" 1'-0" REVISION; 0 11.4.22 - ;.. I DOB FILIN' ' 11 30 22 { !O ' - ... DOB REVI; N 1 19 23 !._ BID S ET 1 26 23 NEW ASPHALT ROOF I PE ON 30"ROOFING i RMIT St T 2.07.23 FELT ON 3/4"PLYWOOD SHEATHING.RIGID INSULATION TO BE ADDED UNDER PLYWOOD ! - t� _ 3 10 ( 1 ..... r 8' j 1/2" l 0 1/2" 1'-8 1/2" 1 in ,. K `n. .I.. 7. i I i i i I W s �H 9 112 r , r I ' I I I I I r I r - I , ico co I ..... . : ... : r N NEW STONE CLADDING------, NEW TO ISTiNG CHIMNEY I r r ' r I I I i I I ; i r• r i. I I. i I, _ I - I REPLACEENT SKYLIGHT ..�� .I.F V SIZES T ' i i I 24'-1 1/2" 1'-0" EW BLACK ROUND GUTTER ry Z � I I rn , i 0 1'-o" 8'-101/2" 1'-0" PROJECT,0DRESS: 890 ARROI /HEAD LN PECONIC I 'Y 11958 ROOF PLAN SCALE: 1 /4"=1'-0" DRAWN B DATE: 1.2! 23 SCALE: DRAWING SHEET NAME: ROO 7 PLAN DRAWING SHEET NO: r ARCHITEC IS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. T NE VENEER ON EXISTING ROOFS+ i M U E L S �c NEW 1"X6"PVC PAINTEDMASORY FIREPLACE S E E L M A N FASCIA BOARD 25235 MAIN ROAD DOOR SCHEDULE NEW PRE-FINISHED CEDAR CUTCHOGUE,NY 11935 ----- --- - --- - ----- --- - --- - ----- -- --- - SIDING ON NEW -_ MANU NUMBER PANEL HARDWARE TYPE J"PLYWOODANDHOUSEWRAP DOOR# WIDTH HEIGHT SINGLE L-LOCK, \\ \\ N P-PASSAGE RA: 1 H- 1 HR RATED NEW PVC 60 PAINTED BOARDS D-DUMMY AT SOFFITS D2 SINGLE L-LOCK, RED AR P-PASSAGE \\ \\ E%ISTING IND TO REMAIN \\ \\ NEJEq/VS C�/T F 21-811 6,-8„ 1 H- 1 HR RATED — ------ — ----- D-DUMMY ” ( -- --- _-- - ---- — --- --- -- UPPER LEVEL CEILING G D3 „ SINGLE L-LOCK, ! . 7 . �r, in ! 21-611 6-8 P-PASSAGE NEW PRE-FINISHED CEDAR SIDING D4 2'-4' 6-8"- --- - ---- SINGLE L-LOCK, 4"PLYWOOD AND HOUSE WRAP P-PASSAGE sr 0443£ ��- NEW WIRE AND WOO i E E \ E E \ O D5 SINGLE -LOCK, RAILING PER SPEC \ O/ O , �OFNE�N� 2'-0" 6'-8" - - P-PASSAGE 00 D-DUMMY �%\ D6 1'-0" 6'-8" SINGLE L-LOCK, ` ——_ P-PASSAGE OWNER: ., .. .., .. - PICTU PICK D7 5'-0" 6'-8" SLIDING CL DUMMY " ' .- ... ..... ._. -. ... ..... �.. .. ... ... WINDOW WINDOW i UPPER LEVEL LINDSEYF VD KEVIN KING ED1 T-0" 6'-8" ELIFD 36"X 80" GLASS SWING KEY LOCK 131 MAPLE STREET X-LHI DEADBOLT C C BROOKLYi 11225 ih ED2 5'-9 1/2" 6'-8" ELSPD 69" X 80"XO 2 PANEL GLASS KEY LOCK M SLIDINGEl 4 A ENTRY LEVEL ED3 5'-8 1/2" 6-8" ELIFD 69 1i X 80" FRENCH GLASS KEY XX-LHI LOCK/DEADBOLT N \\ \\ N \\ \\ REVISION, . . NcoBIDDING E RAFT 11.4.22 i ED4 3'-0" 6'-8" ELIFD 3068 X-LHI SINGLE SWING KEY LOCK NEW SLIDING DOOR OP NEW SLIDING DOOR I u M I � DOB FILIN' ,' 11.30.22 ED5 11 -11 1/2' 6'-8 !ELSPD 12068 OXXO SLIDE 4 PANEL KEY LOCK DOB REVI: ION 1.19.23 L I i - — - ------------ -------- ------ ---- -..- --- - --- --- - - BID SET 1.26.23 LOWER LEVE WINDOW SCHEDULE _ - IRV WINDOW TAG WIDTH R.O. HEIGHT R.O. MANU TAG TYPE MANU PERMIT SE T 2.07.23 A 2'-8" 3'-5" ELCA 16"X 41" 2-LR FRENCH MARVIN CASEMENT NEW PRE-FINISHED CEDAR SIDING INSTALLED—�Z WITH 1"GAPS ON SUBSTRAIT NEW EXTERIOR RATED SCONCE EXISTING FOUNDATION BEYON '' -- --- ---- ----- -------- ---- - - B 7'-8" 6'-2" ELDG 30 z X 74 FIXED MARVIN C 1'-6" 6-2" ELDG 18"X 74" FIXED MARVIN _ TEMPERTED D 3'-0" 5'-10" j ELDG 36"X 74" FIXED MARVIN SOUTH ELEVATION _ TE_MPERED __ D2 3'-0" 5'-10" ELDG 36" X 74" CASEMENT MARVIN SCALE: 114"=V-0" TEMPERED E 2'-8' S,-0„ ELCA 32" X 60" CASEMENT MARVIN F 2'-0" _ 3'-6" ELCA 24" X 43 z" CASEMENT MARVIN G T-0" 4'4" ELCA 18"X 48" CASEMENT MARVIN ! H 2'-2" — 3'-2" ELCA 26" X 38" CASEMENT MARVIN EW STONE VENEER ON EXISTING _.___._. _ MASORYFIREPLACE J 2'-10" 6'-8" ELDG 34 2" X 80" SIDELIGHT MARVIN EXRE ISTING WINDOWTOREMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TOMAIN _— TEMPERED A ROOF K 1'-9" 3'-5" XXX SKYLIGHT VELOX - - - - - - -- - ! -- -- -- --- ------ - --- -- -- ---��-- NEW SIDING ON EXISTIN - - �- L 2'-8" 3'-8" ELCA 32 X 44 CASEMENT MARVIN BUILDING PAPER.REPAIR AS NEEDED NEW ASPHALT ROOF ON 30"ROOFING W FELT ON 3 PLYWOOD N ' SHEATHING.RIGID INSULATION TO BE ADDED UNDER PLYWOOD OD --- R CEMENT IGH RIFLACEMENTSKYLIC T z \\ W I YTY741111111111111111111 UPPER LEVEL CEILING 0 U)EW ROUND GUTTER NEW PRE-FINISHED CEDAR S" 7'.8" g" \\� `\\ \\ \ \\ \\ FASCIA BOARD SIDING ON NEW R ACEMENTIPICTUREWIN DW "PLYWOOD AND HOUSE WRAP \ \\ \\ • \ cCD ------ > 0 z U Z O = W� _j fV N Orik UPPER LEVEL V -8' 1WPICTUREW]N 9g N EW EG P" \ E s """ \S WI"601 ENTRY LEVEL A PROJECT. +DDRESS: NEW METAL TRIM AT GROUND00 M-1 77 N M 890 ARROI /HEAD LN "' Ak r.Rnt IND PECONIC I 'Y 11958 Lu w N = 2 r J -' LOWER LEVE cn co EW STONE VENEER ON DRAWN 8 STAIR STRUCTURE EW WIRE AND WOOD DATE. 1.X x -22 RAILING SCALE: DRAWING SHEET NAME: ELEVATIONS EAST ELEVATION SCALE. 114"=V-0" DRAWING SHEET NO: ^ () Al mm r � ARCHITEC 'S: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S i ► M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. EW STONE VENEER ON EXISTING S E E L M A N MASORY FIREPLACE 25235 MAIN ROAD DOORSCHEDULE CUTCHOGUE,NY 11935 ------- ----- --- -- - - -- - — ----- -- - — - - -- ROOF DOOR# WIDTH HEIGHT MANU NUMBER PANEL HARDWARE TYPE FASCIABOARD D1 2'-10" 6'-8" SINGLE L-LOCK, P-PASSAGE EW 7"X6"PVC PAINTED RA: 1 H- 1 HR RATED FASCIA BOARD _ D-DUMMY NEW PRE-FINISHED CEDAR SIDING ON NEW D2 SINGLE L-LOCK, PLYWOOD AND HOUSE WRAP ��REO ARC 2�_g�� 6�_8�� P-PASSAGE PAINTED O RDS �5 �N�JEA/V, 1H- 1 H RATED ATSOFFITS '` D-DUMMY + GN 2'-6" 6'-8" D3 SINGLE L-LOCK, 7t i P-PASSAGE j D4 2,-4„ 6,-8„ — -- — --- SINGLE MOSAGE UPPER LEVEL CEILING 04436 Q`F' D5 P-PAS SINGLE L-LOCK, z' " I 9T�OFNE`1`I�O 2'-0" 6'-8" P-PASSAGE EW WIRE AND WOOD D-DUMMY \\ RAILING I D6 , „ -- ;--~----- SINGLE L-LOCK, NEW EXTERIOR RATED SCONCE \ 11-01, 6-8 OWNER: — P-PASSAGE W IN OW EW WINDOW CASEME WINDOW WINDOW" WINDOW �,, D7 5'-0" 6'-8" SLIDING CL DUMMY 'F F F L/NDSEY7 VD KEVIN KING NEW F'- ...:.... .. .... ........ .. ED1 3'-0" 6'-8" ELIFD 36" X 80" GLASS SWING KEY LOCK GLASS DOOR _ 131 MAPLE STREET _X-LHI - DEADBOLT PIChU PIG J BROOKLYI ', 11225 ED2 5'-9 1/2" 6'-8" ELSPD 69" X 80"XO 2 PANEL GLASS KEY LOCK N W N -.. _ SLIDING NEW WIRE AND WO jkUPPER LEVEL ED3 5'-8 1/2" ' 6-8" 1„ „ FRENCH GLASS KEY RAILING \ I ELIFD 69 2 X 80 C \\\ C REVISION: _ XX-LHI LOCK/DEADBOLT NEW BLUESTONE STEP \ WITH INTEGRATED ED4 3'-0" 6'-8" ELIFD 3068 X-LHI SINGLE SWING KEY LOCK LIGHTING \\ \\ BIDDING C ?AFT 11.4.22 ENTRY LEVEL DOB FILINI ; 11.30.22 ED5 11'-11 1/2" 6'-8" ELSPD 12068 OXXO SLIDE 4 PANEL KEY LOCK o �? DOB REVR ION 1.19.23 1-7 N N60 p I--------- ------- -------- - - --- - WINDOW SCHEDULE M o co BID SET 1.26.23 GROIJNn WINDOW TAG WIDTH R.O. HEIGHT R.O. MANU TAG TYPE MANU PERMIT SI T 2.07.23 A 2'-8" 3'-5" ELCA 16" X 41" 2-LR FRENCH MARVIN , --- - -- -------- ---- CASEMENT B 71-81' 61-211 ELDG 30 i' X74 FIXED MARVIN LOWER LEVE N " C 1 -6 6'-2" ELDG 1$ X 74„ FIXED MARVIN EXISTING FOUNDATION BEYOND= NEW PRE-FINISHED CEDAR SIDING INSTALLED-----J T_E_M PERTE_D WITH 1”GAPS ON SUBSTRAIT j D 3'-0" 5'-10" -ELDG 36"X 74" FIXED MARVIN _ _TEMPERED \ -D2 3'-0" 5'-10" —ELDG 36"X 74" CASEMENT MARVIN TEMPERED E - 2'-8" 51-011 ELCA 32" X 60" CASEMENT MARVIN NORTH ELEVATION F 21-011 31-611 ELCA 24" X 43CASEMENT MARVIN SCALE: 114"=V-0" G 3'-0" 4'-0" ELCA 18" X 48" CASEMENT MARVIN H 2'-2" 3'-2" ELCA 26" X 38" CASEMENT MARVIN J 2'-10" 6'-8" ELDG 34 2" X 80" SIDELIGHT MARVIN ------NEW STONE VENEER ON EXISTING _ TEMPERED MASORY FIREPLACE I K 1'-9" 3'-5" XXX SKYLIGHT VELOX -- -- - --- ------- -- ---- -- ------- ---- - - I i I I I I I I I I Y - L 2'-8" 3'-8" ELCA 32" X 44" CASEMENT MARVIN - - - - ROOF 177 NEW ASPHALT ROOF U ON 30"ROOFING I JT FELT ON 3/4"PLYWOOD SHEATHING.RIGID INSULATION TO BE ADDED UNDER PLYWOOD \\1\a ui NE SKYL HT NE SKVL HT OD 60 Q 1' �, L4 I 1 11 1 11 1 1 70 1 1 1 1 1 1 1 1 1 1 1 1 1 1—1 1 1 1 1 1 1`11-47LF-Y I I I I I I I I I I I 1 1 1 1 1 L I I aa= I I I I I I I I I I 1 1 1 1 1 1 1 1 Y71 1 1 1 1 1 1 1 1 1 1 OTY4� L� 1 7� U UPPER LEVEL CEILING W z EW WIRE,METAL �E \ \\ / \ \ \ \ AND WOOD NEW EGRES EM NT WINDOW v S SF OPEN RAILING.SEE SPEC R�EPLAC EN INDOW11 \ O -, NEW PRE-FINISHED CEDAR------,, \\ \'\ r7 t I REPLN R \ D2 D2 D2 z / \ O O 6D O "PLYWOOD AND HOUSE WRAPLf SIDING ON NEW ®L RE ENT CASEMENT WIN ' + ... .... CLNEW WINDOW WIT VERTICAL CASING PER DETAIL jh UPPER LEVEL _ 5' /2 2' 1 1W Hill 11111 o PROJECT. ,DDRESS: REP EMENf / REP EMENT EG EG WIN -V.I.F WIN -V.I.F �-7 ENTRY LEVEL 890 ARROI /HEAD LN o PECONIC I 'Y 11958 is � N coNEW SLIDING DOOR NEW SIDELIGHT p CO M � 0 wr DRAWN B` - LOWER LEVEL DATE. 1.2r- 23 Q— SCALE: NEW EXTERIOR RATED SCONCES-t/ EXISTING FOUNDATION BEYON CUSTOM DOOR FOR UNDER DRAWING SHEET NAME: PORCH STORAGE NEW PRE-FINISHED CEDAR SIDING INSTALLE WITH 1"GAPS ON SUBSTRAIT ELEVATIONS 0 WEST ELEVA TION DRAWING SHEET NO: SCALE: 114"=f-0" Asa ARCH/TEC rS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S S E E L M S N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: ,�EFtED Al�C JEAN� Fc) � r 04436 OQ`E FOF NEw� OWNER: LINDSEY/ VD KEVIN KING • 131 MAPLE STREET BROOKLYI ', 11225 -- 4"X 12"TIMBER BEAMS REVISION: EXISTING 5 T&G PINE BIDDING C ?AFT 11.4.22 PLANK RESTAINED EWASRHAi r ROOF rik ROOF DOB FILIN, 11.30.22 ON 30" ROOFING FELT ON 3/4"PLYWOOD DOB REVI: ION 1.19.23 % SHEATHING. RIGID INSULATION BID SET 1.26.23 — - TO BE ADDED UNDER PLYWOOD PERMIT SE T 2.07.23 I � illl I _ co i I 00 I i - I _ ! I I ! I - CV UPPER LEVEL CEILING r r d' �' EO DINING CCDM - \ W SEE KITCHEN ELEVATIONS- P111\ I \ / RY BEDROOM I IL I / ris WfRE6�P60D UPPER LEV L W 11 A } i\ 'v'�' Y1"r V r'YVk YYY' ) —L7ti /� Y I; 7 Y d Y '7 �' 'Y {Y YY RAILING Ec ----, OPING STONE , AT RETAINING WALL M c� --- TOP EXISTING CONC, BLOCK- HALL 6 REBAR VOID FILLED W/ cv _ \ ENTRY LEV L >- VC W/EXISTING INSULATION \\ _CD ry Z - - U_ XL_ -- ==_ ►� LU cN 3 CN 00 c) z BEDROOM DEN 353 Z Q BATHROOM BEDROOMrh GROUND U - `o I I= III III III III �'�"I ch PATIO -- -- a. 41 WE EVE ° PROJECT DDRESS �� - -- _ a ° I i ROt /HEAD LN III -- — _ - — --- ---- _ RAINI WI H PERFJJORATION PECONIC/ Y 11958 - -- -- --- --- XiST1Nb F.J-WITHiN WS�RA' -- _ F�t �JN[�ATiON LATIO' � � _ LtF�NEW S SAY— -- --- - - - - — - - A4�f10NET1�V N � TWENI -- OA INS EEN. EXISTING 24"X 24"X 12" -- -- -- TIEW P YWO b SUBFLOO �– XISTIIV OOT1N OR– ---- �f I� FOOTING --' _.. _ —_ i' _-- --_ ASO Y f� - WAT I ��F IB�l -A� 1M lEl` It�ll C ISS ONIP ISTALSI --- -- - -----NEW OOD F LObRING NI EIRE ! ! ` E— NEW OO BFLOW -- --T IE�VEN N, - �L O RRACE -- I — --- - - ---- ----- - Vv60p F OORI -- _— DRAWN B� . L_1—._ r DATE: 1.2E 23 SCALE: DRAWING SHEET NAME: SEC7ION 1 DRAWING SHEET NO: C) SECTION 1 rm SCALE: 318"=V-0" ARCH/TEC 'S: NOTES ' 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WAL.KTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: JEAlv 04436 OF NF1441O OWNER: LINDSEYF VD KEVIN KING 131 MAPLE STREET BROOKLY1 ', 11225 REVISION: : BIDDING G ?AFT 11.4.22 DOB FILINf ,, 11.30.22 DOB REVI: ION 1.19.23 EXISTING RIDGE BEA EW ASPHALT ROOF BID SET 1.26.23 ON 30" ROOFING ROOF FELT ON 3/4"-PL-YWOOD PERMIT Sl 7' 2.07.23 — — -- — SHEATHING. RIGID INSULATION TO BE ADDED UNDER PLYWOOD REMOVE CEILIN \ AND TRUSS SEGMENTS V.I.F X ` V.I.F NEW 2X10 RR @16" —EXISTING TRUSS N SPRAY FOAM INSULATION TO REMAIN BETWEEN RR NEW BEAM.SEE EW CEILING 00 PLAN FOR SIZING NEW INSULATION EXISTING TIMBERFRAME � ATTIC PER SPEC EW HALF ROUND ALUM TO REMAIN GUTTER 1X6 METAL FASCIA _ TO MATCH EXISTING UPPER LEVEL CEILING =, ' AINTED PVC SOFFIT NEW WINDOWS CONTINUOUS SEE ELEVATION — PAINTED GYP BOAR \ SEE M ROOM ELEVATIONS W EW WINDOWS SEE ELEVATION bo U -- - - FINISH WOOD FLOORIN z ON EXISTING PLYWOOD SUBFLOOR ON EXISTING FL JT. ui UJ t M. BEDROOM "' "' M. BATHROOM = UILD OUT WALLS PER cn cl) =-' PLAN. INSULATION PER SCHEDULE UPPER LEV L . co M EXISTING CONC. BLOCK- U_ 6 REBAR VOID FILLED W/ ENTRY LEVIlL z CONC W/EXISTING INSULATION O U co FINISH WOOD FLOORIN ON EXISTING PLYWOOD SUBFLOOR c") ON EXISTING FL JT. CL BEDROOM -- -- ---- — --- ----- --- ' � — a GROUND BEDROOM - - PROJECT, ;DDRESS: N PECONIC 1 Y 11958 C - -- - - -I - --- -- - - -_-_- _-'--- - -- --- - -—— -- ---I- —'= =--- -- I— --- —— --- DRAWN B' . — -- — - ---- -- - I — - --- E-9 IEE� I ---- ---- DATE. 1.2t 23 -24' !1 2 "X 12' E,VII�tt�SE LIL I9T NGS " 4"X-1 -- - - I T NG Z " �4")" -- -- ----- (---__-- —_--- -- - __FO ING— I PAYFOA 1NSlILATION_ —FCOT�NG — _FOCT�NG I - SCALE: =%, =N�X�SI �Sr$ DRAWING SHEET NAME: UBFLOb SEC' ^ION 2 DRAWING SHEET NO: SECTION 2 SCALE: 318"=V-0" Eft, 0 ARCHITEC rS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: t�VkED ARC r .' 64436 0 F OF IN OWNER: LINDSEY/ VD KEVIN KING 131 MAPLE STREET BROOKLYI ', 11225 REVISION: : BIDDING C RAFT 11.4.22 DOB FILING , 11.30.22 DOB REVR ION 1.19.23 BID SET 1.26,23 PERMIT SE T 2.07.23 BUILDING WRAP AND ASPHALT BUILDING WRAP AND ASPHALT SIDING PER ELEVATIONS SIDING PER ELEVATIONS UPPER LEVEL CEILING UPPER LEVEL CEILING r� I I r NEW WIRE AND WOOD NEW WIRE AND WOO j RAILING WITH 4"X 4"POSTS,AND RAILING WITH 4"X 4"POSTS,AND WIRE EVERY 2" _ WIRE EVERY 4" 2X8 T.W.LEDGER W/14" �` bo 2X8 LEDGER W/14" bo TIMBERLOCK ` TIMBERLOCK W SCREWS @16"O/C ` SCREWS @16"O/C STAGGER TOP+BOT — - _ STAGGER TOP+BOT rr , o' w I 9 N 8"FASCIA PVC BOARD AROUND M M M DECK EDGE k 8"FASCIA PVC PAINTED BOARD AROUND UPPER LEVEL DECK EDGE UPPER LEVELU) NEW PRE-FINISHED CEDAR ------ ,-x r NEW PRE-FINISHED CEDAR �'r z SIDING INSTALLED ��— X> > SIDING INSTALLED gm �— WITH 1"GAPS ON SUBSTRAIT WITH 1 GAPS ON SUBSTRAIT z M M e M j cM (Mv Mlo: — j N ENTRY LEVEL ENTRY LEVE s U T S loo Ch AZD /UNDER DECK = N -1a00, CO STORAGE BEYOND .= iv N aD Hf��"co ih /UNDER DECK N COMPACTED GRAVEL UNDER DECK-- M COMPACTED GRAVEL UNDER DECK STORAGE BEYOND �'> PROJECT,iDDRESS: BLUE STONE PAVERS -- BLUE STONE PAVERS .;�.;.< a.s.•. - . mow., 8 ,GROUND GROUND 90 ARROI iHEAD LN PECONIC VY 11958 SONOTUBES BEHIND SONOTUBES BEHINDr AS DECK FOUNDATION.SEE -- AS DECK FOUNDATION.SEE - _ _ --- --- PLAN FOR LOCATIONS PLAN FOR LOCATIONS � i w — •• LOWER LEVE — — - - .� LOWER LEV L DRAWN B`. DATE: 1.2f 2.3 _ . EXISTING EXTERIOR WA - IS SCALE' WITH NEW SIDING ' E I R O IT I If�G D ' ' RAWING SHEET NAME NEW S - ,j •e EXISTING FOOTER AN ----- ----- X SIG OEN ! ---— - FOUNDP� � �A FOUNDATION WALL -- TINWALL— - - DEC! C SECTION DRAWING SHEET NO: DECK SECTION 4 DECK SECTION 3 SCALE: 112"=V-0" SCALE: 112"=1'-0" ARCHITEC 'S: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO,, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: � ED ARC �r=ANsgi��0 RAILING PER SPEC „1 • �T'9T 04436 OQ�` SOF NEWS REBAR \� OWNER: T �• ;� LINDSEY/ VD KEVIN KING 3• :• \��` 131 MAPLE STREET BROOKLYI 11225 f.w \\ -STONE FACING s� i•' REVISION, : BIDDING C ?AFT 11.4.22 CONCRETE "., PAVER ON PEDISTAL ..._... �\ DOB FILING ' 11.30.22 DOB REVI: ION 1.19.23 N 1 � BID PITCH ET 1 26 23 TO AREA DRAIN M \ PERMITS[ T 2.07.23 10001 RETAINING WALL AT TERRACE SCALE: 1"--V-0 ff W U Z WINDOW AS SPEC w 0 FRAMING AS REQ. 3" PAINTED PVC TRIM PAINTED PVC TRIM NEW 6" CEDAR SIDING w }- AT 1" SLOPE ry z DRIP EDGE WINDOW AS SPEC 2" INTERIOR SILL (D WATERPROOFING AS REQ. FRAMING AS REQ. z \ WATERPROOFING AS REQ. z 0 4" INTERIOR TRIM \ _ O \ NEW 6" CEDAR SIDING , oat PROJECT. DDRESS: s sk 4 :gyp 890 ARROI /HEAD LN INV PECONIC I Y 11958 l 4" INTERIOR TRIM DRAWNB` e \ DATE: 1.21t 23 Ile, SCALE: DRAWING SHEET NAME: SILL DETAIL AT CASEMENT WINDOW JAMB DETAIL AT CASEMENT WINDOW DETALS SCALE: 3"=1'-0" SCALE: 3"=1'--0" DRAWING SHEET NO: All ARCHITEC 7-S: STRUCTURAL REVIEW BY STEVE MARESCA, PE WIND-BOR14E DEBRIS PROTECTION FOR OPENINGS 188- 07 WEST MONTAUK HIGHWAY HAMPTON BAYS Y FOR WAS_!_ OPE==NING PROI FE-C I-ION OL 1 �0 N,1PN .5 - SECOND WIND GUSTS � N 11946 C n M u E L S &PHONE 631 728 9480 MM MAXIMUM EAN ROOF- J E I C I T: �� 1 SIMPSON LSTA - 20 GAGE S i RIDGE STRAP - ALL ROOF RAFTERS S E E L M A N USE/OCCUPANCY 25235 MAIN ROAD 2 x 6 TIE © EACH RAFTER CUTCHOGUE,NY 11935 IN VIEW OF STRAP. CLASSIFICATION DESIGN CRITERIA: ICE SHIELD U SHUTTER ASSEMBLY REQUIRED - 24° FROM EDGE SINGLE FAMILY RESIDENTIAL DESIGN IN ACCORDANCE WITH AMERICAN RA: N.T.S. FOREST PRODUCTS WOOD FRAME FOR PANEL SPANS: 0 < 4'0 WIDL SPAN CONSTRUCTION MANUAL FOR 1 + 2 FAMILY HOUSE 23/32" (3/4") APA SPAN-RATED 48/24 SF1 1,TI 'ING `RAF_"_ "'LY.'JOOD HEIGHT PRESCRIPTIVE METHOD FtEOA>��� (OVERLAP AROUND OPENINGS 4 ) ALTERNATE POSITION OF > >> \ �.JEA/`V I HURRICANE CLIP USE 35 - 0 MAXIMUM GROUND SNOW LOAD - 45 PSF. e`�N ASSEMBLY: SIMPSON H3 ATTACHING STRUCTURAL PANEL: FASTEN TO B"'_DING w/ FIRST LEVEL - 40 PSF. L.L. �. #lOx3" (w/ WASHERS) GALVINI7ED OR STAWI I SS STFFL LIVING AREAS - 40 PSF. L.L. * �, WOOD SCREW @ 16" O.C. SIMPSON H2 HURRICANE BEDROOMS - 30 PSF. L.L. ! ALTERNATIVE FASTENER FOR SHUTTER TOCiUILDING: CLIP NAILED. FROM ##10 TEE NUTS ATTACHED TO BLDG. w/ ##10x1- 1/2 ( W/ `,IVASHI- RS) RAFTER TO STUD. - FIRE AREA WIND SPEED - 130 MPH TYPICAL ALL RAFTERS � _.�«�'o MACHINE BOLT @ 12" 0.�,. 5 - 8d NAILS EACH END RESIDENCE: X SEISMIC DESIGN CATEGORY - B WEATHERING - SEVERET�TFU04 36New APA RATED PLYWOOD TO FROST LINE DEPTH - 36" NES EXTEND TO TOP OF TOP PROVIDE 8d COMMON PLATE. EXTERIOR EDGE OF TERMITE - MODERATE TO HEAVY OWNER: SHEATHING. TYPE OF CONSTRUCTION DECAY - SLIGHT CONVENTIONAL LIGHT FRAME WOOD ICE SHIELD UNDERLAYMENT REQUIRED - YES LINDSEY/ VD KEVIN KING 131 MAPLE STREET CONSTRUCTION BROOKLYI ', 11225 LTIPLE SECTION ASSEMBLY: 1/4" THICK BOLTS @ 2' OC REVISION: GENERALNOTES BIDDING C DAFT 11.4.22 a 00 DOB FILINI ; 11.30.22 1. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN 13. SEWAGE DISPOSAL SYSTEM AND FRESH WATER SUPPLY ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL SHALL BE DESIGNED AND BUILT IN ACCORDANCE DOB REVR ION 1.19.23 CODE, AND THE NEW YORK STATE ENERGY WITH THE SUFFOLK COUNTY DEPARTMENT OF HEALTH. CONSERVATION CODE, AND LOCAL AUTHORITIES. BID SET 1.26.23 14. THIS STRUCTURE HAS BEEN DESIGNED IN of 0 2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A ACCORDANCE WITH THE NEW YORK STATE ENERGY PERMIT SI T 2.07.23 E PLYWDOD SHEATHING MINIMUM 28 DAY STRENGTH OF 3000 PSI CONSERVATION CODE. TO BEAM - TOP LAP e BOTTOM. 3. ALL LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR- 15. ENGINEER TO BE NOTIFIED IN WRITING OF ALL j LARCH STRUCTURAL GRADE ##2 OR BETTER. CHANGES PRIOR TO AND DURING CONSTRUCTION. 4. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL 16. ELECTRICAL AND MECHANICAL COMPONENTS TO BE SHUTTER ASS E B LY DOUBLE TOP STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL DESIGNED AND SPECIFIED BY OTHERS. 2 x 6 @16" O.C. PLATE PARTITIONS, EXCEPT AS NOTED ON DRAWING. STUDS 17. ALL STRUCTURAL STEEL TO BE ASTM A36 WITH ONE N.T.S. FOR PANEL SPANS; 4' OR WIDER SCAN 5. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND COAT EPDXY PAINT. ALL FASTENERS TO BE ASTM FLOOR BEAMS. SPACING NOT TO EXCEED 8.0 FT. A-325 BOLTS, 3/4" DIAMETER. 2.3/32" APA SPAN-Rn TEG �8/2� S IEA JG Gf;nDr ,_ WC OI' 6. ALL DIMENSIONS AND GRADE CONDITIONS TO BE 18. CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSURANCE NECESSARY TO PROTECT THE ENCINEER (OVERLAP AROUND OPENINGS 4") HURRICANE CLIP USE VERIFIED BY CONTRACTOR(S) PRIOR TO START OF AND OWNER. 2x4 STRONG-BACKS @ 2," OC SIMPSON H2.5A 4 - 8c NAILS CONSTRUCTION AND ORDERING OF MATERIALS. THIS FOUNDATION HAS BEEN DESIGNED FOR A SOIL 19. DO NOT BACKFILL AGAINST FOUNDATION WALLS ASSEMBLY: BEARING CAPACITY OF TWO (2) TSF AND GRADES UNTIL FLOOR SYSTEM INSTALLATION IS COMPLETE. E SIMPSON MST27 1 PREASSEMBLE PLYWOOD TO 2x4'S: 10x:3" w b'rA>HF :S AI_VIN17 D OR 1 1/2" WIDE - 20 GAGE LESS THAN 5%. CONTRACTOR SHALL VERIFY THAT #f ( / ) METAL STRAP @48" OC. THESE CONDITIONS ARE MET. ALL FILL BENEATH 20. PROVIDE CARBON MONOXIDE ALARMS ON EACH LEVEL STAINLESS STEEL WOOD SCREW @ ' 2" C.C. 2). ATTACHING STRUCTURAL PANEL: FASTEN:_N TO BU!'.. ` NG v;/ NAIL SHEATHING TO BOX BEAM w/ CONCRETE SLABS TO BE COMPACTED To 95% AND IN BASEMENT ( IF APPLICABLE ). POSITION NEAR 8d NAILS @ 4" O.C. ##1ox3" (w/ WASHERS) GALVANIZED OR STAINLESS cEL RELATIVE DENSITY. ENTRY FROM HOUSE TO ATTACHED GARAGE AREA. WOOD SCREW @ 16" O.C. 21. SMOKE DETECTORS REQUIRED IN EACH BEDROOM AND Al TERNATIVE FASTENER FOR SHU TER O PUI[. DINC: 7. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE ##10 TEE NUTS ATTACHED 0 BLOC. w/ 1{10x1-' %2 \Pd/ WA`�i -PS) SUPPORTED BY DOUBLE UPRIGHTS, 9.0 FT AND OVER ON EACH LEVEL OF DWELLING AS REQUIRED BY E. BOLT @ '12" O.C. NEW YORK STATE BUILDING CODE. MACHINBY TRIPLE UPRIGHTS. ALL HEADERS TO BE SEE FOUNDATION DWG. FOR DESIGN. MINIMUM OF 2-2x8 OR AS SHOWN ON DRAWING. 22• ANY ALTERATION, REPAIR, ADDITION OR CONVERSION TO 8. PROVIDE FIRESTOPPING AT ALL LEVEL AN EXISTING DWELLING REQUIRING A BUILDING PERMIT N DOeVII1!/S - GLAZED OPENING PENETRATIONS NOW REQUIRES THAT ALL SLEEPING ROOMS IN THE 9. PROVIDE FLASHING AT ALL ROOF BREAKS, HOUSE BE UPGRADED WITH HARD WIRED & W PROTECTION IS RWITH LD FOR ISS F. ]A SD ARC S. CHIMNEYS, SKYLIGHTS, EXTERIOR DOORS, WINDOWS INTERCONNECTED SMOKE ALARMS. ' 1 IN ACCORDANCE WITH LARGE '�^ISSILF. l E S I OF v ASTM E 1996 AND OF ASTM 1886. AND DECKS ETC.. CONTRACTOR MAY USE W00D STRUCTURAL_ .''AN-LS 23. THE NYS CODES ALSO APPLY TO ACCESSORY IN LIEU OF THE ABOVE MENTION-D `dVINDO'A/S. HOLD DOWN + SHEAR CONNECTION 10. DO NOT SCALE DRAWINGS. STRUCTURE DESIGN. z G + SI T CRITICAL LOAD PATH u,J PANELS TO BE PRECUT TO F I [ OVER WINDOWS 4^! �H HARDWARE PROVIDED. FAST'-NF-RS TO BE-- CSIG"WJCD 11. ARCHITECTNOR ENGINEER IS NOT RESPONSIBLE 24. GARAGE DOORS TO BE RATED FOR 120 MPH. WIND LOAD PANELS WITH TO BE MA NTAINEDPONTSI ,`I.IEADE�: Li_ ('- �\TE. SHALL COMPLY W NYSBC CHAPTER 2304.9.6 FOR THE INSPECTION OR SUPERVISION OF LABEL LOCATIONS ON EACH PANE[ . / # THIS CONSTRUCTION PROJECT. FEDERAL, STATE AND LOCAL ZONING AND BUILDING CODE COMPLIANCE Q 0 SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. U) -- -------- W 0, ryNAILING SCHEDULE FRAM z 6 IND NOTES TAKEN FROM 2015 EDITION INTERNATIONAL RESIDENTIAL CODE 1. ALL FRAMING LUMBER SHALL BE GRADE STAMPED 10. PLYWOOD SHEATHING TO BE NAILED WITH 8 d @ 4" z .... # DOUGLAS FIR-LARCH STRUCTURAL GRADE No. 2 OR 0.C. EXTERIOR EDGES AND 6 d @ 12" o.c. z O BETTER. e SIZED FOR COMMON NAILS; CONTACT ARCHITECT FOR BOX NAIL SIZES INTERMEDIATE. �- [" 2. ALL SHEATHING TO BE APA RATED, EXPOSURE 1, 5/8" W �» h 11. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING MIN. THICKNESS OR AS NOTED. RAFTER TOP PLATE 3 16d TOE NAILED / ( ) AND WATERPROOFING SHALL BE BY ARCHITECT. e < 10° CEILING JOIST/TOP PLATE 4-8d (TOE NAILED) 3. ALL SUBFLOORING TO BE APA RATED STURD-I-FLOOR, CEILING JOIST/PARALLEL RAFTER 8-16d (FACE NAILED) EXPOSURE 1, 3/4" MIN. THICKNESS. ALL EDGES OF 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE a ° ° "°°°` °' CEILING JOIST LAPS OVER PARTITION 7-16d (FACE NAILED) PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND AND STUD WITH GALVANIZED HURRICANE TYPE NAIL PLYWOOD SUBFLOOR TO FLOOR JOISTS. CONNECTORS BY "TECO" OR APPROVED EQUAL. FOR ° a COLLAR TIE/RAFTER 4-10d (ea. end 1-1/4" strap) TIM R PROJECT. DDRESS: rnQLr ROOFS BLOCKING/RAFTER 4-8d (TOE NAILED) BE PILE FOUNDATIONS, PROVIDE HURRICANE a < 10� 4. ALL HEADERS 6'-0" AND OVER SHALL BE SUPPORTED RIM BOARD/RAFTER 4-16d (END NAILED) WITH DOUBLE UPRIGHTS, 9'-0" AND OVER WITH CLIPS AT ALL PERIMETER JOIST TO GIRDER 890ARR01 iHEADLN ° ° e TOP PLATE/TOP PLATE 2-16d (FACE NAILED) TRIPLE UPRIGHTS. ALL HEADERS SHALL BE A CONNECTIONS. PECONIC i 'Y 11958 ° h TOP PLATE AT INTERSECTIONS 4-16d (FACED NAILED) MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA K STUD/STUD 2-16d (FACE NAILED) 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS PACIFIC GPI SERIES WOOD-I-BEAMS AND LVL HEADER/HEADER 16d (FACE NAILED) AND FLOOR BEAMS AS PER N.Y.S. CODE OR AS NOTED PRODUCTS OR EQUAL. ALL JOISTS, GIRDERS AND 100< A < 450 TOP or BOTTOM PLATE/STUD 3-16d (END NAILED) @ 8'-0" O.C. MIN. PROVIDE 2" SPACE FOR AIR d o HEADERS SHALL HAVE BEARING STIFFENERS INSTALLED BOTTOM PLATE/FLOOR JOIST 3-16d (FACE NAILED) CIRCULATION IN ROOFS. DRAWN B` I © � AS PER MANUFACTURERS RECOMMENDATIONS. WEB JOIST/SILL, TOP PLATE or GIRDER 4-8d (TOE NAILED) 6. DOUBLE FRAMING AROUND ALL OPENINGS ( skylights, STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND r BRIDGING/JOIST 2-10d (TOE NAILED) stairs etc. BEARING POINTS AT A MINIMUM. OR AS NOTED ON DRAWINGS. A SINGLE 1 3/4" DATE: 1.2f 23 GABLE ROOFS BLOCKING/JOIST 2-10d (TOE NAILED) LVL RIM JOIST SHALL BE REQUIRED AT FLOOR SCALE: 00< e ;o n 100< e < 450 BLOCKING/SILL orTOP PLATE 3-16d (TOE NAILED) 7. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PERIMETERS. HANDLING, STORAGE, AND ERECTION OF a LEDGER STRIP/BEAM 4-16d (FACE NAILED) PARTITIONS OR AS NOTED ON DRAWINGS. COMPONENTS SHALL BE AS PER MANUFACTURERS DRAWING SHEET NAME: ° ,<OVID- Fd Cnl� '-)N NAZI S <> 4' O.C. JOIST ON LEDGER/BEAM 3-16d (TOE NAILED) 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED RECOMMENDATIONS. A-- r!IGIi w�l.«1 '� zcN� - e" O.C. BAND JOIST/JOIST 3-16d (END NAILED) HIP ROOFS A- NIERIO� �o?I :s o Ra,�F TYP. BAND JOIST/SILL or TOP PLATE 3-16d (TOE NAILED) WITH RATED GALVANIZED METAL CONNECTORS BY 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" DIA. STR P P i N G NOTES 100< e < so o PLYWOOD ROOF DECKING 8d @4" O.C. EDGES, @8" O.C. FIELD TECO" OR APPROVED EQUAL. GALVANIZED MACHINE BOLTS @ 12" O.C.. STRIP SHEATHING 8d (ONE/RAFTER) 9. NAILING SCHEDULE SHALL BE AS PER THE N.Y.S. PROVIDE 8d NAI; s @ 4" o.;; AT r RIMETEf r,Tr F: PLYWOOD WALL SHEATHING 8d @4" O.C. EDGES, @8" O.C. FIELD BUILDING CODE AS A MINIMUM. ALL 2X6 STUDS 15. THIS DRAWING IS AN INSTRUMENT PREPARED TO POR TIONS OF PANELS iN HIGH PRI SS&RE 70Nr S. NOTE : a = 4 FT. IN AIJ CASES PLYWOOD SUBFLOOR DECKING 8d @6" O.C. EDGES, @12" O.C. FIELD SHALL RECEIVE 5-10D NAILS AT SILL AND PLATE. FACILITATE OSA CONTRACT IRACTTWANDSHN LL NOT AND DRAWING SHEET NO: COMPONENT AND CLADDING PRESSURE ZONES ALL EXTERIOR NAILS SHALL BE GALVANIZED. CONSTRUED A OWNER. BID & PERMIT SET A1111400moo ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING DER. S T E E L M A N 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL 25235 MAIN ROAD INTEGRITY NY 11935 EXISTING WALL RA: NEW WALL �F DUPLEX RECEPTACLE: OUTLET tED ARC�\5�`N�JEANS ATF 220V RECEPTACLE OUTLET 4-7 1/2" 2 101/2" T-6" T-61/2" ���� QUADRAPLEX RECEPTACLE OUTLET J L r G HALF HOT RECEPTACLE OUTLET r. qwp WATER PROOF RECEPTACLE OUTLET ( (mGFI GROUND FAULT INTERRUPTOR OUTLET a W04436 HIGH HAT FIXTURE M ( ( I I sTgTF I OF NEW SURFACE MOUNTED CEILING FIXTUREI I OWNER: k---��–�- SURFACE MOUNTED WALL FIXTURE XT.so" POST I I I I W/axa Pr POST wi SURFACE MOUNTED SPOT LIGHT SIMPSON WITH GALV. I I 2 STIRRUP(TYP) ( I LINDSEYAND KEVIN KING SWITCH EW 12"SONOTUBES I131 MAPLE STREET D SWITCH DIMMER STRUCTURE I I I ( ISTING RETAINING WALL BROOKLYN, 11225 FOR DECK ABOVE IPHI TELEPHONE I I S I REv► ►ONS. TELEVISION I N S/D SMOKE DETECTOR DOB FILING 11.30.22 — — — CM CARBON MONOXIDE DETECTOR BID SET 1.26.23 X SURFACE MOUNTED CEILING FAN I I PERMIT SET 2.07.23 I EX/F EXHAUST FAN PERMIT SET-REVISED 3.6.23 I I I I VE SET 8.1.23 (STING FOUNDATION WALL F SURFACE MOUNTED FLORESCENT FIXTURE I I I PERMIT REVISION 12.13.23 UNDER CABINET MOUNTED FLORESCENT FIXTURE I W O T SURFACE MOUNTED LIGHTING TRACK EXTERIOR WALL MOUNTED FLOOD LIGHT — — — — — EX/F EXHAUST FAN I M " �I o � I Z � #PC SURFACE MOUNTED 'CEILING FIXTURE w/ PULL CHAIN I ► vxx' o Wco Lll ti (STING SLAB.TO REMAI 11-8" z V-0" I I EXISTING GIRDER(3)2x10"C. �, - h. EXIS ING GIRDER(3)2x1 "C.B i EXISTING GARAG ' F,,, DOOR OPENS PA IEXISTING 31 STEEL COMUM ! POSTS AND \` i/ \ CONFIRM 3'X3'X12'FTG EW POSTS AND W FOOTING 3 STEEL COLUMNS F DOTING(3 1 STEEL COLUMNS %, I i N 24"X 24"12"CONC.PAD) ON 24"X 24"12"CONC.PAD) I j EXISTING 31 STEEL COLUMN CXO ING STRUCTURE CONFIRM 3'X3'X12"FTG (ST � ip N FOR MASORY ( O FIREPLACE I EXISTING GARAG I I O M C) DOOR OPENING I`' i N Z W ZT Q T X VX 12"EXISTING W CONC PAD C O EW FLOOR STRUCTUREz ON EXISTING 4"SLAB. SPRAY FOAM INSULATION I I W BETWEEN FLOOR JOISTS. I ool I II II z II II v II II � � z [\-�RTING FOUNDATION WALL O ENTRYWAY ABOVE J ` ,PROJECT ADDRESS: 890 ARROWHEAD LN PECONIC NY 11958 BASEMENT CONSTRUCTION PLAN KS• SCALE: 114"=l!-0" DRAWN BY. DATE, 12.13.23 SCALE: DRAWING SHEET NAME: 'r BASEMENT CONC. PEC o PLANS DRAWING SHEET NO: Apt ArvriE DM ENT 41gD1 A -2:. Amoo PER IT EVI SI® '12. 13.23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRME . 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. El El 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S T E E L M A N 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL 25235 MAIN ROAD INTEGRITY C TCHOGUE,NY 11935 EXISTING WALL RA: 0717 1 171 '777 77 NEW WALL DUPLEX RECEPTACLE OUTLET �\S'(��DAIly 220V RECEPTACLE OUTLET 5 �A QUADRAPLEX RECEPTACLE OUTLET Gc� a Jf I HALF HOT RECEPTACLE OUTLET — — — _ * °t :.,. 'k WP WATER PROOF RECEPTACLE OUTLET /�— � GFI I � \ '�e�c��o 0 GROUND FAULT INTERRUPTOR OUTLET I HIGH HAT FIXTURE 04436 SURFACE MOUNTED CEILING FIXTUREF —D -�- — — —� -@- � F OF NEW�( I - SURFACE MOUNTED WALL FIXTURE --��� — I OWNER: SURFACE MOUNTED SPOT LIGHT T—I T DNI I I � �/ N EXISTING I I 1MAP SWITCH 1� YAND KEVIN KING Y LE STREET I `` --� I I I I I 3 I I I I PATIO BROOKLYN, 11225 SWITCH DIMMER I I I I I I REMOVE EXISTING DECK—/ PATIO RETAINING WALL J IPHI TELEPHONE LY 1 I� I AND STRUCTURE ABOVE TO REMAIN (''�- 5111,71/2" REVISIONS: 0 TELEVISION III — 3'-2" SID SMOKE DETECTOR DOB FILING 11.30.22 CM :2-- BID SET 1.26.23 CARBON MONOXIDE DETECTOR I I X SURFACE MOUNTED CEILING FAN I I I I I EXIST. PERMIT SET 2.07.23 I I 11'-3" 12'-5^EX/F EXHAUST FAN MECH PERMIT SET-REVISED 3.6.23 f � J F SURFACE MOUNTED FLORESCENT FIXTURE L _— VE SET 8.1.23 CLOSET ( I REMOVE OIL TANK "-- EXISTING UNDER CABINET MOUNTED FLORESCENT FIXTURE Q I I FAMILY RM EXISTING N PERMIT REVISION 12.13.23 II T SURFACE MOUNTED LIGHTING TRACK � BEDROOM EXTERIOR WALL MOUNTED FLOOD LIGHT EX/F EXHAUST FAN EXISTING REMOVE WATER TANK *pc SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN GARAGE REMOVE ALL CEILING TILES \ IIHVAC SYSTE TOBEBE REMOVED AND REPLACE REMOVE ALL CARPET—/I IEXIST. EXIST. r CLOSET CLOSET FIREPLACE STRUCTURE ABOX /, REMOVE ALL DOOR TO REMAIN x> �� 6 0 12'-5" O) EXISTING RE AOVE ALL GARAGE DOOR I I BEDROOM Y UP O R OV z �- PLUMBING FI [OVE TAIR EXIST. I W REMOVE ALL TRIM/CASINGS AN MAIN. BATH WINDOWS THOUGHOUT RERPET i iQ �.� 0 21'-71/x" W 11'-3 1/4" 12'-5" EXIST. z ENT A E U z Z 0 U 0- FIRST FLOOR DEMO PLAN PROJECT ADDRESS: 890 ARROWHEAD LN SCALE. 114"=IO" PECONIC NY 11958 DRAWN BY. KS DATE: 12.13.23 SCALE. DRAWING SHEET NAME: 1ST FLR DEMO PLANS DRAWING SHEET NO: DmO01 e PERMIT REVISION '12 . '13.23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. w, 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW'SIZES BEFORE PLACING ORDER. 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL S T E E L M A N 25235 MAIN ROAD INTEGRITY CUTCHOGUE,NY 11935 EXISTING WALL N EW WALL DUPLEX RECEPTACLE OUTLET EFtED ARC 220V RECEPTACLE OUTLET �G�Q�NE IEANS,���F� QUADRAPLEX RECEPTACLE OUTLET NNW HALF HOT RECEPTACLE OUTLET WATER PROOF RECEPTACLE OUTLET (mGFI GROUND FAULT INTERRUPTOR OUTLET LW HIGH HAT FIXTURE I I �� sTq 04436 �EOF NEv`I�O SURFACE MOUNTED CEILING FIXTURE I L OWNER: SURFACE MOUNTED WALL FIXTURE SURFACE MOUNTED SPOT LIGHT T I T� LINDSEYAND KEVIN KING SWITCH I I f EXISTING ( I 131 MAPLE STREET I I i CHECK FOUNDATION PLAN DECK REMOVE EXISTING DECK. BROOKLYN, 11225 D SWITCH DIMMER I I DN FOR DEMO OF STRUCTURE PH �_.L I I I / 0 TELEPHONE -LI _L 21'-111/2" 12'-3" 15-01/2" W TELEVISION — �' REVISIONS: S/D SMOKE DETECTOR DOB FILING 11.30.22 CM CARBON MONOXIDE DETECTOR _ _ _ _ __ _ _ _ _ _ _ _ _ _ — BID SET 1.26.23 - - - X SURFACE MOUNTED CEILING FAN PERMIT SET 2.07.23 I II it I REMOVE EXISTING WINDOEXHAUSTFAN ` PERMIT SET-REVISED 3.6.23 F SURFACE MOUNTED FLORESCENT FIXTURE I I I I I I I EXISTING EMOVE GYP VE SET 8.1.23 UNDER CABINET MOUNTED FLORESCENT FIXTURE I I I I I I I KITCHEN I TO EXPOSE TRUSSES PERMITREVISION 12.13.23 T SURFACE MOUNTED LIGHTING TRACK I I I I I I I �- I EXTERIOR WALL MOUNTED FLOOD LIGHT EX/F EXHAUST FAN +PC SURFACE MOUNTED CEILING FIXTURE w/ PULL CHAIN I I I I I I I I EXISTING I I I ( I REMOVE ALL DUCTWORK I I EMOVE ALL TILE,CABINETRY, BEDROOM AND VENTS I I COUNTERS,APPLIANCES I I I I I TWALLI �R>F I I I I I OVEN EXISTING I �` %f N N - - -� I- LIVING ROOM - - -I- - - - - - - - - - - - - - - - - EXIST. II II it I PANTRY EXIS {% LAUN RY I I I --REMOVE ALL CARMIFINISHES CEILING AND TRUSSE ate, TO BE REMOVED I Ii II II J � I II II _ I I I I I I CEILING TO REMAI I I I (IF POSSIBLE) N REPLACE SKYLIGHT EMOVE WINDOW. W i I 11(EEP EXISTIN 1 IN SAME LOCATION �� EXIST. CHECK ELEVATION J BATH v ON NEW WINDOW 1 1 STAIRS 1 1 DIMS. 0 II II N II I I I i I I EXIST. EXISTi I I i t I CLOSET W I I I I I BA H" �Q IEPLAME LCE OCO�I - - - - - 1L - - - - - - - - - - - - - Lam- \ _ _ 0 ;:Aj- DN 24'-1 3/4" I ENTRY I I I I I (� z I v II L I II I II _ IL Z o EXIST. Ti_ ( w CLOSET T I I 8'-101/2" 111OVE STEPS AND HARD ADE {I LI L - PROJECTADDRESS: J 890 ARROWHEAD LN PECONIC NY 11958 SECOND FLOOR DEMO PLAN SCALE: 114"=f-0" DRAWN BY. KS DATE: 12.13.23 SCALE. DRAWING SHEET NAME: 2ND FLR DEMO PLANS DRAWING SHEET NO: D =002ml PERMIT REVIS101"mm 12. 13 .23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S T E E L M A N 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL 25235 MAIN ROAD INTEGRITY 3 4 CUTCHOGUE,NY 11935 EXISTING WALL EW STAIRS IN DECK ELISE EXISTING POSTS AND FOOTINGS.REPAIR A DAMAGE AND DISCUSS WIT ARCHITECT PRIOR RA: Ti NEW WALL 23'-3" DUPLEX RECEPTACLE OUTLET 4'-8 1/2° T-61/2' T-6- 7'-6 v2^ 10'-7 v2^ G\��N D A/V 220V RECEPTACLE OUTLET S PEW CEDAR SLAT DOORS ( f`# t QUADRAPLEX RECEPTACLE OUTLET UP ER ELEVATION cn HALF HOT RECEPTACLE OUTLET — — � 3-2X8 TR. IND. ISTING RETAINING WALLS NIP WATER PROOF RECEPTACLE OUTLET UP WITH NEW STUCCO ON 044 LV GROUND FAULT INTERRUPTOR OUTLET EXTERIOR INTERIOR SIDE 7J HIGH HAT FIXTURE STORAGE ® 3-2X8 TR. IND. ��qTF OF N S -�- SURFACE MOUNTED CEILING FIXTURE EXISTING PAVER z — OWNER: SURFACE MOUNTED WALL FIXTURE — ----NEW POSTS P® N SURFACE MOUNTED SPOT LIGHT AND FOOTINGS I 2 LANDSEYAND KEVIN KING SWITCH — o a 131 MAPLE STREET BROOKLYN, 11225 $D SWITCH DIMMER 2X8 TR.WD. LEDGER W/14" 12'-5" PH TELEPHONE TIM@16'O/K ti F► SC ER (P+ O/C a [L 5'-11"V.I.F 5-0" 3'-11/2" 5'-9" 3'-5" STAG ER TOP BOT REVISIONS: RELOCATED OI TA TV TELEVISION � VENT AT EXT DOB FILING 11.30.22 S/D SMOKE DETECTOR 1 J. / /// CM CARBON MONOXIDE DETECTORBID SET 1.26.231r " a ` 3-74"LVL HEADER PERMIT SET 2.07.23 X SURFACE MOUNTED CEILING FAN N ® F 108 PERMIT SET-REVISED 3.6.23 NEW 3-2X6 STUDS EX/F EXHAUST FAN BELOW 6X6 POSTS,TYP. ; a VLF SET 8.1.23 F SURFACE MOUNTED FLORESCENT FIXTURE UNDER CABINET MOUNTED FLORESCENT FIXTURE PERMIT REVISION 12.13.23 N T SURFACE MOUNTED LIGHTING TRACK " i N BEDROOM 1 All�lEXTERIOR WALL MOUNTED FLOOD LIGHT `� o Y — — 1 L EX/F EXHAUST FAN GYM i FAMILY ROOM SURFACE MOUNTED CEILING FIXTURE W/ PULL CHAIN NEW FLOORING 107 I N PC D 1Q1 NEW FLOORING ON NEW WASHER D SUB FLOOR ON LAUNDR I m I- ON CONCRETE SLAB NEW FLR JTS 109 I a I EW 3-2X6 POST EXISTING POST ABOV EW -2X6 STUDS N NEW POSTS AN 35'FRIDGE BELO 6X6 POSTS,ON DOOR SCHEDULE FOOTING. \ F-0" 5'-1 6._ " 10"M SONRYWALL DOOR# WIDTH HEIGHT MANU NUMBER TYPE HARDWARE TYPE K' '., 3-111 LVL GIRDER 04 N D1 2'-10" 6'-8" FLAT P-PASSAGE ------- �IXISTING GIRDER ABO � �`, � VE 1 H-1 HR RATED �. N 12'-01/2" 7 N N N N D-DUMMY HALLco �� D2 FLAT L-LOCK, M 110 L EW 3LALLY CQLU 2'-8" 6'-8" P-PASSAGE EXISTING GRAVEL �- 3'-4 1 H-1 HR RATED DRIVEWAY TO REMAIN � f., D-DUMMY NEW FLOORIN NEW FLOORIN D3 , , , FLAT L-LOCK, ON NEW . ON CHEW FL E SLAB 2-6" 6-8' BEDROOM 2 P-PASSAGE SUB FLOOR ON � 402 a D4 FLAT L-LOCK, iv NEW FLR JTS I I 102 2'-4' 6-8 P-PASSAGE IN EW FLOORIN 1 ON CONCRETE SLAB D5 FLAT L-LOCK, 2'-0" 6'-8" P-PASSAGE UP L D-DUMMY m 0 0 106 D6 „ FLAT L-LOCK, BEDROOM 3 I BAT 105 OM ® 4 11-01, 6-8 P-PASSAGE � 401 D7 4'-0" 6'-8" SLIDING CL DUMMY I I 2'-6" 3' 2'-71/2" I 5'-4co " T IN BELOW 6X6 POSTS,TYP. J3-2X6STUDS D8 6'-8" POCKET-FLAT LOCK !! BATHROOMrx) 21-4" I ® 8 . ( 104 D92,-0„ 6'-8" 1 -HOUR RATED PASSAGE FLAT NEW HEADER NEWNEWHFADER ED1 T-0" 6'-8" ELIFD 36"X 80" GLASS SWING KEY LOCK _— X-LHI DEADBOLT 4 ?. ED2 5'-9 1/2" 6'-8" ELSPD 69"X 80"XO 2 PANEL GLASS KEY LOCK 1 1 SLIDING 3'-51/2" 5'-3" 1'-10" '` '*, �.jJ Em 5'-8 1/2" 6'-8" ELIFD 69 2"X 80" FRENCH GLASS KEY a'-z" 6'-2^ 4'-101/2^ }- XX-LHI LOCK/DEADBOLT 11'-61/2" 9'-612':. _' 11'- ^?'� 12'-5^ ED46'-8" ELIFD 3068 X-LHI SINGLE SWING KEY LOCK 3,-0„ 49'-7 1,2-' Y V ED5 6'-8" ELSPD 12068 OXXO SLIDE 4 PANEL KEY LOCK l l-11 1/2 WINDOW SCHEDULE Ew8"CONCRETEFOUNDA710N U EXISTING CRAWL t�: WINDOW TAG WIDTH R.O. HEIGHT R.O. MANU TAG TYPE MANU '; SPACE UNDER ENTRY ; WALL FOR STAIRS ABOVE A 2'-8" T-5" ELCA 16"X 41"2-LR FRENCH MARVIN •.; �' �.. CASEMENT B T-8" 6'-2" ? FIXED MARVIN - ,.•_a• �' " `� ELDG 30 2 X 74 a ::�•:.;�;.:,•.` ;,�'.; '; 3'-0 2'- C V-6" 6'-2" ELDG 18"X 74" FIXED MARVIN #4 REBAR DOWEL 6'-5" TEMPERTED AT 24'OC-12"LONG --------- PROJECT ADDRESS: D 31-0" 5'-10" ELDG 36"X 74" FIXED MARVIN W/6"EMBEDED F TIO TEMPERED 890 ARROWHEAD LN D2 T-0" 5'-10" ELDG 36"X 74" CASEMENT MARVIN PECON/C NY 11958 TEMPERED E 2'-8" 5,-0„ ELCA 32"X 60" CASEMENT MARVIN F 2'-0" 3'-6" ELCA 24"X 43 2" CASEMENT MARVIN MARVIN IST FLR CONSTRUCTION PLAN DRAWN BY. KS G T-0" 4'-0" ELCA 18"X 48" CASEMENT H 2'-2" 3'-2" ELCA 26"X 38" CASEMENT MARVIN SCALE: 114"=f-0" DATE: 12.13.23 J 2'-10" 6'-8" ELDG 34 2"X 80" SIDELIGHT MARVIN SCALE.- TEMPERED DRAWING SHEET NAME. K 1'-9" 3'-5" XXX SKYLIGHT VELOX L 2'-8" 3'-8" ELCA 32"X44" CASEMENT MARVIN FIRST FLOOR PLANS DRAWING SHEET NO: Aml OOmOl PERMIT REVISION 12 . 13 .23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALK"THROUGH REQUIRED BEFORE WIRING. S A M U 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. E L S & 5. PROVIDE SHORING AS REQ. TO MAINTAIN STRUCTURAL S T E E L M A N INTEGRITY 3 q MAIN ROAD CUTCHOTCHOGUE,NY 11935 EXISTING WALL RA: !7.! NE'J1/ WALL EW TREX STAIR TREADS. SEE SPEC DUPLEX RECEPTACLE OUTLET 23'-6" ED ARC 220V RECEPTACLE OUTLET �EANsy/��� 4-7 1/2" 18'-10112" QUADRAPLEX RECEPTACLE OUTLET HALF HOT RECEPTACLE OUTLET ==0 * ' `"P WATER PROOF RECEPTACLE OUTLET { FNM AL DWIRE RAILING!S51:SPEC I117GFI GROUND FAULT INTERRUPTOR OUTLET i tP 0 4436 HIGH HAT FIXTURE T,9T LV NEWTR x )EC(. -�- SURFACE MOUNTED CEILING FIXTURE I SEE PEC OWNER: F- SURFACE MOUNTED WALL FIXTURE j { SURFACE MOUNTED SPOT LIGHT N I DECK I 2 LINDSEYAND KEVIN KING SWITCH 131 MAPLE STREET Dhl BROOKLYN, 11225 o SWITCH DIMMER 121'- 11'-11" 15'-0" '8 1 2" 8'-11 12" 1'-6 -8 /2 5'-0 1/2" 4'-4 1/2" 5'-1 - PH TELEPHONE h 0 4'9 1/2" ?'-71/2" T-6" UILD OUT GYP REVISIONS: Q I BOARD WALL TV TELEVISION ' D S/D SMOKE DETECTOR { L — — D OD DOB FILING 11.30.22 - - - - — CM CARBON MONOXIDE DETECTOR _ _ _ _ _ BID SET 1.26.23 - - - - - - - -- - - I — N EXISTING HEADER TO REM I PERMIT SET 2.07.23 X SURFACE MOUNTED CEILING FAN I � DRAWERS i TRASH 24"DW CORNER �I CABINET EW WHITE OAK z -C"4 FLOORING THOU OUT PERMIT SET-REVISED 3.6.23 EX/F EXHAUST FAN I I ITC NCABINE � Q N VE SET 8.1.23 F SURFACE MOUNTED FLORESCENT FIXTURE I �aNDr sTALLBYOTHERs TRY N UNDER CABINET MOUNTED FLORESCENT FIXTURE ( \ 7`0" M I N PERMIT REVISION 12.13.23 T SURFACE MOUNTED LIGHTING TRACK I 2 2" 2-2 2 2 3'-5" k ,� L /< EXTERIOR WALL MOUNTED FLOOD LIGHT _ ( _ _ .0 RI N ISLAND I I o N M EX/F EXHAUST FAN ---------- ----------1----------, �r +PC SURFACE MOUNTED CEILING FIXTURE W/ PULL CHAIN EW WHITE OAK I DRAINERS N 400 M BEDROOM OORING iHOUGHOUT ; iI205 z ti BUILD OU GY BOARD WALLKITCHEN 8 NEW<-2x4 POST I 206 M <7 N NEW TILE SURROUN 36'FRIDGE I XB POST W 4-2X6 ' NEW BXB POST TO RIDGE. DOOR SCHEDULE AT FIREPLACE BLOCKING BELOW i� EXIS7ING 6X6 POST TO REMAIN DOOR# WIDTH HEIGHT MANU NUMBER TYPE HARDWARE TYPE N N ;T,{Y MICROWAVE D1 2--1 0 6-8 FLAT L-LOCK, I _ �� 2'-6" N OUSTING 2- HDR NEW RIDGE B 311 I LVL P-PASSAGE ° r 3'-4' ao co 1 H- 1 HR RATED04 15, LIVING ROOM I j FOOD D2 FLAT DL-DLUMM 202 A, 2a' GE , PANTRY A1 ; FRIUGE 11 „ P-PASSAGE k ----�--_ P UP TO RR waus 2'-8 6'-8" 1 H- 1 HR RATED HANGERSI @ EAC TRUS a j 24'BEV P D-DUMMY ..,:;r FRIdGE " cu D3 2'-6" 6'-8" FLAT L-LOCK, 2 P-PASSAGE UILD OUT GYP D4 2'-4" 6'-8' FLAT L-LOCK, BOARD WALL NEW METAL RAILING WIT HEADER ABOVE i 1 P-PASSAGE 401 HALLWA L MED CAB _N PICKETS AND HEIGHT PER CODE. D5 FLAT L-LOCK, HANDRAIL SOILD OAK STAINED TO EXISTIN 20 I 2'-0" 6'-8" P-PASSAGE I MATCH FLOORING " SKYLIGHT a D6 FLAT DL-DLOCKY I L . 1" FLOORING 7 Ew2X6 16" EW TILE 4 3 1'-0" 6'-8" NEW SOLID OAK O w P-PASSAGE I PBA e M BATH D D GABLE TW D7 4-0 6'-8" SLIDING CL DUMMY I STAINED OTMATCH DN 203 , 204 FLOORING I Z W.LC D8 2,�„ 6'-8" POCKET-FLAT LOCK I q o 03 e u D9 6 1 -HOURARATED PASSAGE 2,_0„ I — — �XISTING ' — SKYLIGHT FL — —— — — — — — -8" — — — — N ED1 T-0" 6'4" ELIFD 36"X 80" GLASS SWING KEY LOCK 6101/101,60,111,101100 X-LHI DEADBOLT - ED2 5'-9 1/2" 6'-8" ELSPD 69"X 80"XO 2 PANEL GLASS KEY LOCK DN — SLIDING W ED3 5'-8 1/2" 6'-8" ELI FD 69 2"X 80" FRENCH GLASS KEY C C 5'- " 10'-51/2" 7'-3" XX-LHI LOCK/DEADBOLT 17'-7" 4'-0" 3'-6 1/2" 10'-5 1/2" ED4 T-0„ 6-8 ELIFD 3068 X-LHI SINGLE SWING KEY LOCK N ENTRY 6' o N ( U ED5 j ---;) 11' 11 1/2" -8" ELSPD 12068 OXXO SLIDE 4 PANEL KEY LOCK NEW WINDOW v 200 I 1L �P (DZ WINDOW SCHEDULE Z O WINDOW TAG WIDTH R.O. HEIGHT R.O. MANU TAG TYPE MANU EW STONE STEPS �� V A 2'-8" T-5" ELCA 16"X 41"2-LR FRENCH MARVIN TILE FLOOR G" AND RAILING CASEMENT B T-8" 6'-2" ELDG 30 2 X 74 FIXED MARVIN o 2-zX10 I II 1'-0" O -0" 11" 11" 11" 11" C 1'-6" 6'-2" ELDG 18"X 74" FIXED MARVIN 3'-0" 11" '� TEMPERTED NEW POST--Ll�-, D T-0" 5'-10" ELDG 36"X 74" FIXED MARVIN 8'_101/2" 6'-8" PROJECT ADDRESS: TEMPERED D2 T-0" 5'-10" ELDG 36"X 74" CASEMENT MARVIN 890 ARROWHEAD LN TEMPERED \----NEWWINDOWS PECON/C NY 11958 E 2'-8" 5,-0, ELCA 32"X 60" CASEMENT MARVIN F 2'-0" T-6' ELCA 24"X 43 z" CASEMENT MARVIN G T-0" 4'-0' ELCA 18"X48" CASEMENT MARVIN 2ND FLR CONSTRUCTION PLAN DRAWN BY.•KS H 2'-2" T-2" ELCA 26"X 38" CASEMENT MARVIN SCALE: 1 /4°=1 O" DATE: 12.13.23 J 2'-10" V-8" ELDG 34 2"X 80" SIDELIGHT MARVIN ALE: TEMPERED K 1'-9" 3'-5` XXX SKYLIGHT VELOX DRAWING SHEET NAME. L 2'-8" 3'-8" ELCA 32"X 44" CASEMENT MARVIN SECOND FLOOR PLANS DRAWING SHEET NO: A=2u'mkO ,mOl PERMIT REVISION 12. '13.23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTI-IROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S T E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: OWNER: LINDSEY AND KEVIN KING 131 MAPLE STREET BROOKLYN, 11225 REVISIONS: DOB FILING 11.30.22 'v IV \Z _ �� — �� — � � � — � B/D SET 1.26.23 \ PERMIT SET 2.07.23 / NEWRIDGEBEA0 EW ASPHALT ROOF / PERMIT SET-REVISED 3.6.23 SEE PLAN FOR SIZE ON 30"ROOFING < rik ROOF VE SET 8.1.23 —�— FE���r3/4"PL)WOOD —�— SHEATHING.SPRAY FOAM PERMIT REVISION 12.13.23 NEW ROOF RAFTERS / INSULATION (R-30) SEE PLAN FOR SIZE \ �. BETWEEN NEW ROOF RAFTERS REMOVE EXISTIN � i V.I.F s;. V.I.F CEILING TO EXPOSE TRUSS 1 `x ..., ` < NEW 2X10 RR @16" SPRAY FOAM INSULATIONf" x RAFTERS EW FRAMING TO ROOF f BETWEEN RR I\ , �' .� 1 NEW GYP BOAR , / u ? ON NEW RR '' / \ \ / / \ \ 1 EW F ROUND ALUM GUTTER EXISTING TIMBERFRAME ' TO REMAIN f \ / r, 1X6 METAL FASCIA v / TO MATCH EXISTING / EXISTING TIMBERFRAME < UPPER LEVEL CEILING its L NEW WINDOWS —PAINTED PVC SOFFIT SEE ELEVATION <\ CONTINUOUS REPLACEMENT WINDOW REPLACEMENT WINDOW 1 PAINTED GYP BOAR / '\ N LIJ r EW WINDOWS cy SEE ELEVATION U 1 00 FINISH WOOD FLOORIN z ON EXISTING PLYWOOD SUBFLOOR 1 t / ON EXISTING FL JT. w / 0 NEW 2x6 WALL M. BEDROOM EW 2x6 WALL AT INTERIOR / AT INTERIOR Aik UPPER LEV L Cn r r . EXISTING GIRDEce z \ / M M C) EXISTING CONC. BLOCK < 6"REBAR VOID FILLED W/ 1 ENTRY LEV L z CONC W/EXISTING INSULATION / < CD V I co \I c� 00 W \ r- Zh �- FINISH WOOD FLOORING CL = BEDROOM < ON EXISTING CONCRETE SLAB. — \ GROUND - - - = -I - ---! BEDROOM PROJECT ADDRESS: - - --- - - ''I ---/ - - - - - - - - - j- - E 890 ARROWHEAD LN I I - - --� PECONIC NY 11958 LOWER LEVEL, I I II I I II II ' I DRAWN BY. KS DA TE. 12 13 23 - ---- -- --- ---- - XISTING 24"X 4"X 1I2" XISTING 2I�4"-X-24I X i12, XISTING 24"X 4 X 24"X 12" - S CALE: FOOTING OOTINGF ------ FOOTING DRAWING G SHEE T NAME.l l SECTION 2 DRAWING SHEET NO: SECTION 2 SCALE: 3/8"=1'-0" AM Ae ■ PERMIT REVISION 12 . 13.23 ARCHITECTS: NOTES 1. EXISTING DIMENSIONS ;SHOWN IN PLAN TO BE CONFIRMED. 2. PRIOR TO DEMO, WALK THROUGH REQUIRED. 3. ELECTRICAL WALKTHROUGH REQUIRED BEFORE WIRING. S A M U E L S & 4. CONFIRM WINDOW SIZES BEFORE PLACING ORDER. S T E E L M A N 25235 MAIN ROAD CUTCHOGUE,NY 11935 RA: OWNER: LINDSEYAND KEVIN KING 131 MAPLE STREET ,BROOKLYN, 11225 XISTING 4"X 12"TIMBER BEAMS � —" u/ \�// \� � � u � � � � —' � —' �/ � �/ � v v ✓ �/ �/ � � �/ � � ✓ / REVISIONS: XISTING a T&G PINE ( DOB FILING 11.30.22 PLANK RESTAINED _ LEW ASP OF - II E TW�IIII- A-�SIIII /.P:.NI _; Ay�I ELIIi��II�XTWIIII+-RvO eO-III FFIrI �-R�!IIIIII z>T 'vilIliIi/ � IIII'�,II�i ---I -- -------'--I-- I - -I- rrr�- - _ -I�----+- -G_ROOF OOF iII -_ --- --- - - - _ - �I!I -. - II�, NBE/D SSE-ET T �W UUQ „ 1.26.23 BY OTHERS ON 30"ROOFING PERM/TSET 2.07.2 3FELT ON 3/4" PLYWOOD SHEATHING.SPRAY FOAM EW PINE BOARD(STAINED) PERMIT SET-REVISED 3.6.23INSULATION(R-30) FINISH AT CEILING 8.1.23 PERMITREVISION 12.13.23 co ! I ( 00I Hil Hl EXISTING TIMB RFRAME XISTING TIMBERFRAME UPPER LEVEL CEILING EW 2x6 WALL AT INTERIOR NEW 2x6 WALL AT EXTERIOR \ 00 DINING M SEE KITCHEN ELEVATIONS P MARY BEDROOM UPPER LEV L If if ih HALLEXISTING CONC.BLOCK 6"REBAR VOID FILLED W/ N ENTRY LEV L VC W/EXISTING INSULATION ZD Lo 00 NEW CONCRETE PAVERS - -1 ON MUD BASE TO M co2"BELOW INTERIOR FLOOR Z BEDROOM DEN ELEVATION Z 0 BATHROOM BEDROOM ROUND ,LOWER LEVE PROJECTADDRESS. 890 ARROWHEAD LN PECONIC NY 11958 CONCRETEX(STING XISTING CONCRETE SLAB EW F.J.WITH NEW' ISPRAY SLAB ON GRADE WITHWITH NEW UNDERLAYMENT FOAM INSULATION BETWEEN. DRAIN TO REMAINXISTING 24"X 24"X XISTING FOOTING FOR WATERPROOF SLAB AND LVL FLOORING FOOTING CE UBFLOOEWCONCNEW PLYWOOD S NEW LVL FLOORING OPENING DRAWN BY K --WALLATDOORRETE DATE12 13 23 SCALE: DRAWING SHEET NAME: SECTION 1 BE DRAWING SHEET NO: SECTION 1 SCALE: 3/8"=1=0" ■ PERMIT REVISION 12 . '13.23