Loading...
HomeMy WebLinkAbout48493-Z SUFFOC��r Town of Southold 12/22/2022 o P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43715 Date: 12/22/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 3915 Stillwater Ave, Cutchogue SCTM#: 473889 Sec/Block/Lot: 137.-1-5.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/15/2022 pursuant to which Building Permit No. 48493 dated 11/15/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Zoumas,Ioannis of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48493 11/18/2022 PLUMBERS CERTIFICATION DATED ly6th4rizenature TOWN OF SOUTHOLD �$o8°SUFf��K y BUILDING DEPARTMENT a TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS . UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48493 Date: 11/15/2022 Permission is hereby granted to: Zoumas, loannis 2050 North Country Rd Wading River, NY 11792 To: Install a 48kw generator to an existing single family dwelling as applied for. Must maintain a minimum 10 foot side yard setback. At premises located at: 3915 Stillwater Ave, Cutchogue SCTM #473889 Sec/Block/Lot# 137.-1-5.1 Pursuant to application dated 11/15/2022 and approved by the Building Inspector. To expire on 5/16/2024. Fees: ACCESSORY $100.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $85.00 Total: $235.00 Building Inspector pF SOU�y®lo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlina-town.southold.ny.us Southold,NY 11971-0959 COU �•� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: loannis Zoumas Address: 3915 Stillwater Ave city,Cutchogue st: NY zip: 11935 Building Permit#: 48493 Section: 137 Block: 1 Lot: 5.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: YES Electric License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 48kW Kohler Generator w/ (2) 200A Transfer Switches Notes: Generator Inspector Signature: Date: November 18, 2022 S.Devlin-Cert Electrical Compliance Form tio�aOF SODlyolo # # 'TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATIOWCAULKING [ ] FRAMING /STRAPPING ] FINAL (64YW*4� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: d)19N c_ &0 __70- U() ATE 1 INSPECTOR Vtk FIELD INSPECTION REPORT DATE COMMENTS It FOUNDATION (1ST) ------------------------------------ Lo C FOUNDATION (2ND) /z 0 ROUGH FRAMING& PLUMBING �- r INSULATION PER N.Y. STATE ENERGY CODE 'i TZ FINAL L IN ADDITIONAL COMMENTS (9310 5 JZ55 /r slyZz � o �0 z �rn 3 O z x y x b ro y O��SUfFU1k�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y? Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 o` y�ol� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only T-- 9`3 ` iL� �PERMITNO. Applications and forms must be filled out in their entirety. I.ncompiete NOV 2022 applications.will not be accepted.,where.the Applicant isnot-the owner,an Owner's Authorization-form(Page 2)shall be completed:. Date:10.18.22 OWNER(S),OF PROPERTY: s s ZOum e:loan NamnlaSCTM #1000- _ -- ---------- ------------- --- - - Project Address:3915 Stillwater Ave Cutchogue NY 11935 Phone#:631-929-5500 FEmail:John@jnsdevelor)ment.com Mailing Address:256 RT 25a Wading. River NY 11792 cONTACT PERSON: w Name:Vincent Yannucci Mailing Address:PO Box 638 Shoreham NY 11786 Phone#:631-258-7324 _ _ Email:Vinny_@y_eselectricalinc.com DESIGN PROFESSIONAL INFORMATION: Name:Vincent Yannucci Yannucci Electrical Services Inc. Mailing Address:PO Box 638 Shoreham NY 11786 Phone#^631-258-7324 Email:Vinny@Yeselectricalinc.com_ CONTRACTOR INFORMATION: Name:Vinny Yannucci Yannucci Electrical_Services, Inc Mailing Address:PO Box 638 Shoreham NY 11786 Phone#:631-258-7324 Email:Vinny@yeselectricalinc.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Eil Other GENERATOR $24,500.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION' .' ' : Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check:Box'After Reading: The owner/contractor/design professionaP ss responsible for all drainage and storm water issues as provided by Chapter 236 of the Town.Code: APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit'purs uant to the Building Zone,; Ordinance:of the-Town of Southold;Suffolk,,County,New York and,other applicable Laws,ordinances or Regulations,for the construction of,buildings, lte additions,.arations or for.removal or demolition as herein described.The'applicant agrees to comply with all applicable laws,ordinances;building code; housing code and regulations and to admit authorized inspectors on premises and in building(s)for,necessary inspections:False statemedts.made herein are ' 'punishable:as a class A misdemeanor,pursuant to Section 210.45 of the New York State Penal Law, Application Submitted By(print name):Vincent Yannucci BAuthorizedAgent ❑Owner Signature of Applicant: Date: 10.18.22 CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York No.01BU6185050 SS: Qualified in Suffolk County COUNTY OF Suffolk ) Commission Expires April 14,2z)�,q Vincent Yannucci being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)heisthe Eleetrcial Contractor (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this o. 6y of lJ , 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, loannis Zoumas residing at 2050 N Country Rd, Wading River, NY 11792 Vincent Yannucci do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. 10. 18.22 Owner's Signature Date oannis Zoumas Print Owner's Name 2 J �gufFUL BUILDING DEPARTMENT- Electrical Inspector =ZOO' OG,L''ct TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 0 0 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(o-southoldtownny.-gov — sea nd(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10.18.22 Company Name: Yannucci Electrical Services, Inc. Electrician's Name: Vincent Yannucci License No.: 50592-ME Elec. email:Vinny@yeselectricalinc.com Elec. Phone No: 631-258-7324 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 638 Shoreham NY 11786 JOB SITE INFORMATION (All Information Required) Name: loannis Zoumas Address: 3915 Stillwater Ave , Cutchogue, NY 11935 Cross Street: Track Phone No.: 631-929-5500 Bldg.Permit#: Li 94 93 email:John@jnsdevelopment.com Tax Map District: 1000 Section: Block: Lot: 5 1 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 48KW GENERATOR Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES n&/ NO Issued On Temp Information: (All information required) Service Size F11 Ph❑3 Ph Size: A # Meters Old Meter# EJ New Service[:]Fire Reconnect[—]Flood Reconnect❑Service Reconnect[:]Underground❑Overhead # Underground Laterals 1 R2 D H Frame D Pole Work done on Service? DY F1N Additional Information:48KWGENERATOR PAYMENT DUE WITH APPLICATION 10-9-e- ift- 915 SPI:�J� NOTES PROPERTY 1. U&MLIR:NENTSAREINA000RDANCE WRNu9.STAMARDS. T e OF 1L`/,1{ ' 2 1 SEAR/A958NOVMAREMiEWroR%srarEFUfECOORDINATE SYS/EL NAD6( 0 1NNIS ZOT'�VMAS TBE LONGISUND IDNE S ELEVATIONS RVTRMW NaVD lW.. ON SUBDMSION MAP OF '. U94UTHOR7EDALTgRAMgGR"FWNTDASNwEYA(APDEAR`NGA"C D PROPERTY OF M.S.HAND LAND SURVEYORS SEN.LSA MLATIONOFSECRONrM,,SUBDMSKINL OF7/fE NEWroRKSTATEEDUCAMNUW. LOTS 15 AND 16 S OM COPIESFROUTWO)UGW CFn SWMEYNAR: OiANCNIOINALOF V(EuwoSURVEYORS lE BOSSED•DRWZrsEALSNAUBECONsmEREDWOE FILED SEPTEMBER 18,1930 AS MAP NO.730 YALO1 TRUE COPIES. SITUATE AT 6. CERIIRCATRINS IMI:AMHEREON SIGNIFY THAT THIS SURVEYWASPREPAREDIN ACCORDANCE V NlMEEtl3TIN000DEOFPRACr FOR LAM SURVEYORS CUTCHOGUE ADOPTED aW PR YTNENE YORKSTATEASSOCIATION OFOFESSIONAL LAND ¢IIS-e StRIVEYORS.SWCERTFICATMSSNauRUN ONLY70THE PERSONFOR WNW TOWN OFSOUTIIOLD THE SURVEYASPREPAREDAND ONHISBBGIF TO INE INLECOWANY. ASSIGGOVENESOFT ELENDINGI LENDING M CERVIONl CNSTED NEREONAWTTRA S TRE SUFFOLK COUNTY,NEW YORK I ADDEESOFTN TIrU IM ORSURIOrL CERTWIGi�ONSARE N07 TRArlSFERAaIE TO AODmONAL INSrrMANS OR SUBSEOVEMOWNFRS wGHrs•OFwavnorswwNARExorcmnTeD. LOT 17 AREA OF PARCEL = 32,724± SQ.FT. OR 0.751± ACRE R rraesuRVEreLosESNArrmwneNLr. `_ (AREA TO TIE LINE AT HIGH WATER LINE) 4 POST AND N 44.22 28' E 345,10' �rrw,a6w I ` O FEMCE a1'N =� 2' VIRE FENCE 1 ` C:i ,.r I Z �` ✓' hes'04.cS RRA.V No Y X a 3 9 > 7J a LNT 16La 3 cu I, cy U W Rf CONCRETE >3 vT \D ----------- FOUNDATION ,, i < 3� ---------- ---- 1 -- ------ N F- Z Lar y+° J " u y w H all CONC. � I1 In W v � (n LOT 15 I z < ------------ q ———————— I VDOD BOATER 122.0' u\ 1 1 11l 1TWE ass r�r&W U� l S 46 12'48' W 348.96' a PEND-DSw ]W l LOT 14 W SUFFOLK COUNTYREAL PROPERTY TAX MAP l ,`fCOF NEW, DISTRICT 1000 y'lQ•p�p 1. 137.00 ST/ ��� BLOCK SECTION 01.00 LOT 005.001 � Z TRACK a LEGEND AVE .n,,...... .nr FAND,ROv U v -- ELEVATION ` DLT6 9Y aERCR�i19N APPROV.HY (50' O+.......o'c"' �+^ 050528 �A REVISIONS WIDE) o Ymnla" �Aj�• Town of Sout oold N/F ®'' ''yT+LTY rwa�.E ELANDS Suffolk Count New Yark TOWN OF SOUTHOLD 9 TLR NEER .......VaL II.9915 STLWATER AVENUE ® CUTCHOGUE NEW YORK ——_— 92Vo•••• •wOnr Pa E 1 hereby cerOyth0t thtsmap was made fmm an actual survey FOUNDATION AS—BUILT — _ —.— ••••• Iwnmrxawn vArER completed by me an 12/302021. —— ......uroarRaum DAs L. K. MCLEAN ASSOCIATES, P.C. CONSULTING ENGINEERS h LAND SURVEYORS -+I 0_-- ,, e_ /1J�7 A 437 80.COUNTRY ROAD,aROD®VRN,NRR YORE ORAL SIN\ ��(,�yr y..��BY JPIJPt L•a JO• , w TAMARAL.505LMAN,P.L.S. NYSPLS No.50528 R\2D092LO9]91]6'(El.Otlr Aw.Cu! \Sures DrpT\WAv \P092Dmr FM ASR 6/29/E91/1�1T PM Ta,.ero Stltlnu M�•M M TIS. E9n92W9 1 0-CF) oc� APPROVED AS NOTED DATE (-IL B.P.#`3 COMPLY WITH ALL CODES OF NOTIFYY BUILDING DEPARTMENT AT FEE: 00 BY NEW YORK STATE & TOWN CODES S AS REQUIRED AND CONDITIONS OF 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED SOUTHOIfl TOWN FOR POURED CONCRETE 2. ROUGH FRAMING,PLUMBING, SOUTHOLD TOWN PLANNING BOARD STRAPPING, ELECTRICAL&CAULKING 3. INSULATION ` 4. FINAL CONSTRUCTION&ELECTRICAL SOUTHOLD TOWN TRUSTEES MUST BE COMPLETE FOR C.O. N.Y.S.DEC ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES-OF NEWS YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECTION REQUIRED PhoneKOHL9 CO., Kohler,Wisconsin 9-164 USA WORHL.ER. Model: 48RCLB KOHLER, Phone 9 nearest ales Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 Multi-F-91_ KOHLERPower.com LPG/Natural,., Jitiolnal RDC2 Controller Features Available Options (continued) ® Diagnostic messages Enclosure option ®�®�� Standard Features C]o Displays diagnostic messages for the engine, generator, 291 kph (181 mph)wind load rated enclosure Model RXT transfer switch, programmable interfaceStartin Aids§ (A m Kohler Co. provides one-source responsibility for the module (PIM), and load shed kit ❑ Block Heater, 120 V NATIONALLY�`��o generating system and accessories. o Over 70 diagnostic messages can be displayed p Block Heater,240 V o The generator set and its components are prototype-tested, © Maintenance reminders § Recommended for ambient temperatures below o°C 32°F Y'%� factory-built, and production-tested. © System settings '+ `°°- ,a '! ' � s The generator set accepts rated load in one step. Controller Accessories �� �' _ 9 P P• o System voltage,frequency, and phase ❑ Lockable Emergency Stop(lockout/tagout) rtu Fxy,,-; y-"::. "<• -H-ra +;y:V'- = a A standard 5-year/2000-hour limited warranty covers all o Voltage adjustment ❑ Programmable Interface Module(PIM) a`. :.%'" "yR , systems and components. o Measurement system, English or metric (provides 2 digital inputs and 6 relay outputs) Quick ship (QS) models with selected features are available. * ATS status (Model RXT ATS required) Automatic Transfer Switches and Accessories ' - See your Kohler distributor for details. o Source availability ❑ Model RXT Automatic Transfer Switch o RDC2 Controller o ATS position (normal/utility or emergency/generator) C] Model RXT Automatic Transfer Switch with combined interface/ n o One digital controller manages both the generator set and a and frequency q y C] Model RDT Automatic Transfer Switch ( optional Model RXT ATS o Source voltage fre C] Load shed kit for RDT or RXT load management board �i� transfer switch functions with o . � ) o ATS control (Model RXT ATS required) o Designed for today's most sophisticated electronics. o Source voltage and frequency settings ❑ Power relay modules(use up to 4 relay modules for o Electronic speed control responds quickly to changing o Engine start time delay each load management device) demand. o Transfer time delays ❑ Other Kohler®ATS o Digital voltage regulation protects your valuable o Fixed pickup and dropout settings Miscellaneous The Kohler® Advantage electronics from harmonic distortion and unstable power o Voltage calibration quality. 9 ❑ Rated Power Factor Testing a High Quality Power e Programmable Interface Module (PIM) status displays Literature Kohler generators provide advanced voltage and ® Engine Features o (active/inactive) General Maintenance Literature Kit status Input frequency regulation along with ultra-low levels of o Powerful and reliable Kohler 6.2L liquid-cooled engine p ❑ o Output status (active/inactive) ❑ Overhaul Literature Kit harmonic distortion for excellent generator power quality to o Electronic engine management system. ® Load control menus ❑ protect your valuable electronics. o Simple field conversion between natural as and LP va or Production Literature Kit P 9 P-_. Load status Warranty a Extraordinary Reliability fuels while maintaining emission certification. Kohler is known for extraordinary reliability and o Innovative Cooling System Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty performance and backs that up with a 5-year/2000-hour o Electronically controlled fan speeds minimize generator Generator Set standard Features limited warranty. set sound signature. e Aluminum Sound Enclosure o Approved for stationary standby applications in locations © Aluminum sound enclosure with enclosed silencer Dimensions and Weights Aluminum sound enclosure is standard. served by a reliable utility source. * Battery rack and cables Optional 291 kph (181 mph) wind-load-rated enclosure Overall Size, L x W x H, mm (in.): 2280 x 836 x 1182 ® Certifications ) o Electronic, isochronous governor (89.8 x 32.9 x 46.5 door kit is available for field installation. © Fast Response o The 60 Hz generator set engine is certified by the * Engine-generator set is designed and manufactured in Shipping Weight,wet, kg(lb.): 767(1690) Environmental Protection Agency (EPA)to conform to the facilities certified to ISO:9001. Kohler's Fast-Response"o X excitation system delivers New Source Performance Standard (NSPS)for stationary Weight includes generator set with engine fluids and 4Q7BX alternator, excellent voltage response and short-circuit capability spark-ignited emissions. o Flexible fuel line sound enclosure,and silencer. using arare-earth permanent magnet (PM)-excited © Gas fuel system (includes fuel mixer, electronic secondary alternator. o UL 2200/cUL listing is available (60 Hz only). gas regulator, two gas solenoid valves, and flexible fuel line o Quiet Operation o CSA certification is available (60 Hz only). between the engine and the skid-mounted fuel system Kohler home generators provide quiet, neighborhood- o Accepted by the Massachusetts Board of Registration of components) H friendly performance. Plumbers and Gas Fitters. e Integral vibration isolation © Line circuit breaker Generator Set Ratings e Oil drain extension Standby Ratings © OnCue®Plus Generator Management System for remote W L Natural Gas LPG monitoring (see specification sheet G6-140) Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps o Operation and installation literature NOTE:This drawing is provided for reference only and should not be 120/208 3 60 48/60 167 50/62 173 o RDC2 controller with built-in battery charger used for planning installation. Contact your local distributor for more 127/220 3 60 48/60 158 50/62 163 rY 9 detailed information. 120/240 3 60 48/60 144 50/62 150 ® Standard 5-year/2000-hour limited warranty DISTRIBUTED BY: 4P7BX 277/480 3 60 48/60 73 50/62 75 220/380* 3 50 38/48 73 40/50 76 Available Options 230/400 3 50 38/48 70 40/50 73 Approvals and Listings 240/416* 3 50 38/48 67 40/50 70 ❑ UL 2200 Listing(60 Hz only) 4Q7BX 120/240 1 60 48/48 200 48/48 200 -CSA Approval (60 Hz only) * 50 Hz models are factory-connected as 230/400 volts. Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. RATINGS: All three-phase units are rated at 0.8 power factor. Al single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility-.,.._J. 'Electrical System The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. Obtain technical ❑" Battery information bulletin TIB-101 for ratings guidelines,complete ratings definitions,and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Availability is subject to change without notice. Contact your local Kohler generator distributor for availability. ❑ Battery Heater ©2018 Kohler Co. All rights reserved. G4-276 (48RCLB) 7/21d G4-276 (48RCLB) 7/21d .- VW Alternator Specifications Application Data Specifications Alternator o The unique Fast-ResponseO X excitation system delivers Cooling RDC2 Controller Manufacturer Kohler excellent voltage response and short-circuit capability using a rare-earth, permanent magnet (PM)-excited alternator. Radiator System 60 Hz 50 Hz ' 4-Pole, Rotating Field Ambient temperature, °C(°F) 45(113) E type Brushless, Rare-Earth ® Brushless, rotating-field alternator. Radiator system capacity,including Permanent Magnet ® NEMA MG1, IEEE, and ANSI standards compliance for engine,L(gal.) 21.3(5.6) v°nege: z<ov Leads:quantity,type Freq: 60.0 Hz temperature rise and motor starting. Engine jacket water flow, Lpm (gpm) 131 (34.6) 109(28.8) O p O 4Q7BX 4, 120/240 Heat rejected to cooling water at rated o a o 4P7BX 12, Reconnectable © Sustained short-circuit current of up to 300% of the rated kW,dry exhaust,kW(Btu/min.) 48 (2730) 44(2500) � o O 98 O Voltage regulator Solid State,Volts/Hz current for up to 10 seconds. Water pump type Centrifugal OW AUTO Insulation: NEMA MG1 Fan diameter,mm (in.) qty.3 @ 356(14) ® Sustained short-circuit current enabling downstream circuit Fan power requirements(powered by ° Material Class H breakers to trip without collapsing the alternator field. Temperature rise 130°C, Standby engine battery charging alternator) 12VDC, 18 amps each Bearing: quantity,type 1,Sealed v Self-ventilated and dripproof construction. The RDC2 controller provides integrated control for the Coupling Flexible Disc Operation Requirements Amortisseur windings Full o Windings are vacuum-impregnated with epoxy varnish for pgenerator set, Kohler Model RXT transfer switch, Voltage regulation, no-load to full-load ±1.0% RMS dependability and long life. Air Requirements 60 Hz 50 Hz programmable interface module (PIM), and load shed kit. Unbalanced load capability 100%of Rated Standby Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status Current a Superior voltage waveform from a two-thirds pitch stator and m3/min. (scfm) 62.2(2200) 62.2(2200) One-step load acceptance 100%of Rating skewed rotor. Air over engine,m3/min. (cfm) 31.1 (1100) 31.1 (1100) messages and system settings that are clear and easy to read, Peak motor starting kVA: (35%dip for voltages below) e Total harmonic distortion (THD)from no load to full load with Combustion air,m3/min. (cfm) 5.5(195) 4.6(162) even in direct sunlight or low light. 480 V,400 V 4P7BX(12 lead) 180(60 Hz), 136(50 Hz) a linear load is less than 4%. Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features 240 V 4Q7BX(4 lead) 113(60 Hz) Fuel Consumption= o Membrane keypad: Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz o OFF,AUTO, and RUN pushbuttons Application Data 100% 24.8 (875) 21.5 (759) o Select and arrow buttons for access to system 75% 20.3 (717) 17.6 (622) configuration and adjustment menus Engine (Exhaust 50% 14.5 (512) 12.6 (444) ® LED indicators for OFF, AUTO, and RUN modes Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz 25% 8.7 (307) 7.5 (266) o LED indicators for utility power and generator set source type y LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz availability and ATS Manufacturer Kohler Exhaust manifold t e Dr position Model RXT transfer switch Engine:model,type KG6208 6.2L Exhaust flow at rated kW, m3/min. (cfm) 16.4(580) 13.6(480) 100% 9.3 (329) 8.1 (285) required) Natural Aspiration Exhaust temperature at rated kW,dry 75% 6.5 (231) 7.1 (251) a LCD screen: Cylinder arrangement V-8 exhaust, °C (°F) 649 (1200) 50% 4.9 (172) 4.2 (149) P-'-d rpm 1800 1500 Maximum allowable back pressure, 25% 3.1 (110) 2.7 (95) o Two lines x 16 characters per line Acement, L(cu.in.) 6.2(378) kPa(in. Hg) 10.2(3.0) _ Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent and stroke, mm (in.) 101.6 x 95.25(4.00 x 3.75) Exhaust outlet size at engine hookup, LP Vapor,93 MJ/m3(2500 Btu/ft3) visibility in all lighting conditions Compression ratio 10.5:1 mm (in.) 76(3.0) OD LP vapor conversion factors: © Scrolling system status display Max.power at rated rpm, kW(HP) 77.0 (103) 64.3(86) 8.58 ft.3=1 Ib. o Generator set status Cylinder head material Cast Aluminum Fuel 0.535 m3=1 kg. o Voltage and frequency Piston type and material High Silicon Aluminum Fuel System 36.39 ft.3=1 gal. o Engine temperature Crankshaft material Cast Iron Valve(exhaust) material Forged Steel Fuel type LP Gas or Natural Gas e Oil pressure Fuel supply line inlet 1 in.NPT Governor type Electronic pp y o Battery voltage vp Sound Enclosure Features Frequency regulation, no-load to full-load Isochronous auragas fuel supply pressure, q y re Natural fl l g o Engine runtime hours Frequency regulation,steady state ±1.0% kPa(in. H2O) 1.2-2.7(5-11) o Sound-attenuating enclosure uses acoustic insulation that LPG vapor withdrawal fuel supply meets UL 94 HF1 flammability classification and repels a Date and time displays Frequency Fixed Air cleaner type Dry pressure,kPa(in. H2O) 1.2-2.7(5-11) moisture absorption. o Smart engine cooldown senses engine temperature Fuel Composition Limits* Nat.Gas LP Gas o Internally mounted critical silencer. o Digital isochronous governor to maintain steady-state speed Engine Electrical Methane,%by volume 92 min. - o Skid-mounted, aluminum construction with two removable at all loads Engine Electrical System Ethane,%by volume 4.5 max. - access panels. e Digital voltage regulation: ±1.0% RMS no-load to full-load Ignition system Electronic Propane,%by volume 1.0 max. 87 min. Propene,%by volume 0.1 max. 5.0 max. u Scratch-and corrosion-resistant Kohlero cashmere o Automatic start with programmed cranking cycle Battery charging alternator: C4 and higher,%by volume 0.3 max. 2.5 max. powder-baked finish. o Programmable exerciser can be set to start automatically on Ground (negative/positive) Negative Sulfur, ppm mass 25 max. any future day and time, and to run every week or every two Volts(DC) 12 Lower heating value, Sound Data weeks Ampere rating 130 MJ/m3Btu/ft3 min. 33.2 2260 ( )� i890( ) 84.2 ( ) Model 48RCL6 sound levels are 57 dB(A) during weekly engine o Exercise modes Starter motor rated voltage (DC) 12 Fuels with other compositions may be acceptable. If your fuel is exercise and 61 dB(A) during normal operation.recommended cold cranking o Unloaded exercise with complete system diagnostics amps(CCA): outside the listed specifications, contact your local distributor for All sound levels are measured at a distance of 23 ft. 7 m from o Unloaded full-speed exercise further analysis and advice. ( ) P Qty., rating for-18°C(0°F) One,630 the generator set. Actual sound levels may vary based on o Loaded full-speed exercise (Model RXT ATS required) Battery voltage(DC) 12 Lubrication installation parameters. o Front-access mini USB connector for SiteTech"' connection Battery group size 24 Lubricating System a Integral Ethernet connector for Kohler®OnCue® Plus Type Full Pressure © Built-in 2.5 amp battery charger Oil pan capacity, L(qt.) 5.7(6.0) Oil pan capacity with filter, L(qt.) 7.11 (7.5) o Remote two-wire start/stopcapability ca abilit for optional connection Oil filter:quantity,type 1,Cartridge of a Model RDT transfer switch See additional controller features on the next page. G4-276 (48RCL6) 7/21d G4-276 (48RCL6) 7/21d