Loading...
HomeMy WebLinkAbout49000-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 49000 Date: 3/8/2023 ........ Permission is hereby granted to: Murphy, Rachel 11220 Soundview Ave Southold, NY 11971 �......... ............. ........ _..............._. To: Install an accessory 16 x 30 in-ground swimming pool to an existing single family dwelling as applied for per ZBA (conditions), DEC Non-Jurisdiction letter, and Trustees approvals. At premises located at: 21695 Soundview Ave, Southold SCTM # 473889 Sec/Block/Lot# 135.4-7 Pursuant to application dated 8/17/2022 and approved by the Building Inspector. ._/ To expire on 6/2024.9 w.__..w....,.........r_.w_....... Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO- SWIMMING POOL $50.00 __.............. Total: $300.00 Building Inspector �Ft TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 kltt s:// w .sotitlioltgMluiy. ov m APPLICATION U Date Received FOR BUILDING PERMIT For Office Use Only � �1 lu PERMIT NO. AJ Building Inspector:� Applications and forms must be filled out in their entirety.Incomplete BIT-DING D u,�T applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: g 2-c2-7- OWNER(S)OF PROPERTY: Schon I3�ocIL L.4 Name: e.he 1Mur h• ISCTM:#:1000- 13 0 l 0-1 Project Address: Sounc�vl'ec�t So� �v4 ��1 1�q1 � Phone#: V 1 -692- - 62-112- Email: i c7 r� �hL Q-O on 1,nC- nc.i- Mailing Address: Z1(.9S S• IArid v,'eVI) �� •-'S"Ako CONTACT PERSON: Name: 1 (11a ' vv� ,�5 SAA Mailing Address: O'A \k- -L 5 Phone#: Email: S0Je-S AcG n2ef a0\S . 6Zrn DESIGN PROFESSIONAL INFORMATION: Name: f�2�► ✓ler-��i n Mailing Address: y Co,r S a SAY-1 c� �S; �( �S Y� Phone#: us3 - A5,4 - 008'1 Email: K b r o c►n�i✓� A c CONTRACTOR INFORMATION: Name: �\ c A vno L3'V4 A4'i �r Mailing Address: k�5 Z Phone#: �3 i_ SSI _ Q2� Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other e h oil, $ 57-,000 Will the lot be re-graded? ❑Yes 21Vo Will excess fill be removed from premises? ❑Yes E rfVo 1 PROPERTY INFORMATION Existing use of property: S`�n I !� I Intended use of property: S' 0 U Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to i p0© this property? ❑Yes ❑No IF YES, PROVIDE A COPY. dCheck Box After Reading. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name). �(a2y i ,,,,��,s -}zj �7Authorized Agent ❑Owner Signature of Applicant: ( �- Date: "C049. S STATE OF NEW YORK) SS: COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the C4 '4-t--,2- nt - (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 9� day of ,20 0a` Notary Public D ANS DO' WY YORK I TI r� � O K COUNTY PROPERTY OWNER �'"x t: Wa� �E°° ,�FF (Where the applicant is not the owner) jjXPBESAUG0 ,20 residing at j 2.2, J �H u �Ck do hereby authorize to apply on my behalf to e o of 'ob old Building Department for approval as described herein. 6 I er's Signature Date Print Owner's Name 2 K P B Keviri P . Berto .lini ,A r c h i t e c t August 10, 2022 TO: Town of Southold Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Attn.: Mr. Michael J. Verity Chief Building Inspector Re: Swimming Pool for Rachel Murphy 21695 Soundview Ave. Southold , NY 11971 Dear Mr. Verity This is to certify that the designed construction of a swimming pool on the above referenced premises will not require special drainage facilities. The swimming pool will be conStrUcted of pneumatically applied steell reinforced gunite and the poowater is designed to be COrItinUOUSly recirculated through the filter and ireused from year to year. The drainage -from the-filter backwash cycle is nominal and therefore will not interfere with the public water supply, the existing sanitary facilities, neighboring property and/or public highway. 'The swimming pool shall be constrUcted to conform 'to the 2020 IRC with W SUpplernent and the ICC swimming pool and spa code. Therefore it will not interfere with the pn,nblic water supply, the existing sanitary facilities, neighboring property and/or public highway. Any make up water required will be drawn from a hose bib which shall have a vacuum breaker. Sincerely, Kevin R. 16ertolini 14 Corsa Street , Dix Hills , New York 11746 6 3 1 -2 5 4-0 0 8 7 — k p b c r t @r o p t o n I i n e . n e t K P" A B Kevij'i. P . Bertolin. i ,A r c h i t e c t August 10, 2022 TO: Town of Southold Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold, NY 11971 .Aftn.: Mr. Michael J. Verity Chief Building lnspector Re: Swimming Pool for Rachei Murphy 21695 Soundview Ave. Southold , NY 11971 Dear Mr. Verity This is to certify that the swimirning pool heater, for the above ireferenced premises, will conform to Section R403.10,1 thmUgh R403.10.3 of the 2020 Energy Bon servation Construction Code of New York State., Sincerely, "I"F 'U") J o' oll Kevin P, Be-tolini( "e 14 Corsa Street , Dix Hills , N (.-. w York 11746 631 -254 -0087 — kpbert@i), optonline . net 41k\ NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ^AAAA^ 112451261 LOVELL SAFETY MGMT CO.,LLC 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 IM01362 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ALCAMO SUPPLY&CONTRACTING CORP THE TOWN OF SOUTHOLD 1152 JERICHO TURNPIKE 54375 NY 25 COMMACK NY 11725 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER r POLICY PERIOD DATE Z1382 116-0 409172 04/01/2022 TO 04/01/2023 7/26/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1382116-0, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND DIRECTORMSURANCE FUND UNDERWRITING VALIDATION NUMBER:98066819 workers• nsatlon CERTIFICATE OF INSURANCE COVERAGE lr ComPe Boaird NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) ib.Business Telephone Number of Insured Alcamo Supply & Contracting Corp 631-543-8820 1152 Jericho Turnpike Commack, NY 11725 Work Location of Insured(Only required if coverage is specifically limited to 1c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 11-2451261 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Guardian Life Insurance Co. The Town of Southold 3b.Policy Number of Entity Listed in Box la 54375 NY 25 Southold, NY 11971 988609-0000 3c.Policy Effective Period 01/15/1990 to 01/14/2023 4. Policy provides the following benefits: ® A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C.Paid Family Leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or Gasses of employer's employees: Under penalty_ofperjury, _ u , I certify that I am an authorized re - - perj ry fy presentativ or " nsed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insuractttver e a dt scribed above. Date Signed Jule 26, 2022 " BY t&gnataure fin arta carrier's authorized repre at've of NYS i6censed insurance agent of that insurance carrier) Telephone Number (212)964-2150 Name and Title President IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers' Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 11111 II NIBlllllllallllll1111011111111111111111111 DB-120.1 (12-21) Client#: 11221 ALCASUP ACORD,,., CERTIFICATE OF LIABILITY INSCJ N CIHDATE(MM/DD/YYYY) 7/26/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:H the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Commercial Support Edgewood Partners Ins.Center PHONE631 324-1440 LArc,lr�o �:_ ... ....._..wwww 40 Marcus Drive E IIdA1L NEcertificates a icbrokers.com w 3rd Floor INSURER(S)AFFORDING CO A1�IR�ESS: _... .. _._.... .. Melville,NY 11747 �.--_____ _ w ._...�..-__,_------COVERAGE NAIc a mM INSURER A:Regent Insurance Company 24449 _......... _M.M..._.M.M......,,,,........_................. _. _ __. 1111._ .............. INSURED INSURER B:General Casualty Company of WI 24414 Alcamo Supply&Contracting Corp _...............__ 1152 Jericho Turnpike INSURERC: Commack,NY 11725 INSURER D INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ..,. _ TYPE OF INSURANCE m_.._m...._..w_..ADDL UIB i ...w. POLICY NUMBER _,.. MMOLIC YXFYFY M � P _w-w...... ...-wm_...w .LINKS m. _M...... _._.ww_._..... .. _ 1111...._w............_-,� .._._... --M._.M... ....-w............................... _..,- __ _._..-w...w-w w_w_.-_, vw..(..W,.w.... x.. .� 1 �.......... _._m.._.w.......W...................w.......................... A X COMMERCIAL GENERAL LIABILITY BPK000960201 3/04/2022 03/04/2023 EACH OCCURRENCE $1 000 000 .. ppMA�ET RENTED .... CLAIMS-MADE 7 OCCUR P{2FA11SES acaQO0 MEO EXP(Any one person $10500 �__...... ..,. _PERSONAL& 1111..-..w -,.Y.....,_1, 0 l PERSONAL&ADV INJURY $1 OOO OOO EN'L AGGREGATE LIMIT APPLIES PER: GEN ER_AL AGGREGATE $2,000, 000 __ww .,_ .........._. ,_.... POLICY PRO- -„ LOC PRODUCTS COMP/OPAGG $2,000000 OTHER: - $ B AUTOMOBILE LIABILITY BCA000610501 03/04/2022 0.____. CX7�kB&PPLO SIPIC'rG.B LIMIT 3/04/202 ! WN112s . X1,000 000 XANY AUTO BODILY INJURY(Per person) $ OWNEDASCHEDULED BODILY INJURY(Par accident) $ AUTOS ONLY S _. UTO HIRED NON-OWNED PROPERTY OAMHC",E X AUTOS ONLY X AUTOS ONLY $ 11_B_._.._ _„ ..X.µoccuR.................. BUM000933001 __. _.................. RENCE $2 000 OOO A UMBRELLA LIAB ._,. .....____..___,.... 3/04/2022 O3/O4/202 EACH OCCUR_._.w..vw _1111. $2 OOOMOOO _w_...... EXCESS LIAB CLAIMS-MADE AGGREGATE .�...... ----ww ._www_.w_. 1111 ..M._-r 'ENTIO ......,,,....1111 ----- _ .... _. WORKERS COMPENSATION N 10000 Y/N PER I0 - $ AND EMPLOYERS'LIABILITY TATLT .._,..,.. fA , _- -- PROPRIETOR/PARTNER/EXECUTIVE[ EACH SEASECEDAE NETMPLOYEE $OFFICER/MEMBER EXCLUDED? ....M (Mandatory In NHIT NIA If $ Yes,describe under DESCRIPTION OF OPERATIONS belowE L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION The Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 NY 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold, NY 11971 AUTHORIZED REPRESENTATIVE O 1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S4188413/M3483191 TM006 Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name JOHN P ARCILESI Business Name This certifies that the nearer is duly licensed ALCAMO SUPPLY&CONTRACTING CORP :Py the County of suffolk License Number:H-5280 Rosalie Drago Issued: 07101/1979 Commissioner Expires: 07/01/2024 POOL & HOTTUB ALLIANCE N 1 V Confers upon John Si The designation CBIP Certified Pool & Spa Building Professionalsm for meeting the education requirements,successfully passing an objective examination and pledging to uphold the PHTA Code of Ethics. April 2018 04/30/2024 O""'� '�'� p/' Expiration Date _ `- ` _ ® President&CEO Pool&Hot Tub Alliance NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Environmental Permits,Region 1 SUNY @ Stony Brook,50 Circle Road,Stony Brook,NY 11790 P:(631)444-03651 F:(631)444-0360 %"w.dec.ny.gov LETTER. OF NO-JURISDICTION May 30, 2019 Michael and Rachel Murphy Re: Application ID 1-4738-03938100002 11220 Soundview Avenue 21695 Soundview Avenue Southold, NY 11971 Southold SCTM # 1000-135-1-7 ARNO-DEP Dear Applicant: Based on the information your,agent submitted,the New York State Department of Environmental Conservation (DEC) has made the following determination. The portion of the referenced property landward of the existing bulkhead and concrete seawall totaling more than 100 feet in length and originally constructed prior to 8/20/77, as evidenced on Aerial linage Resources aerial photograph dated 4/6/1976 (E Pf#72-2020) and shown on the survey prepared by Metes and Bounds Surveying last dated April 12, 2018, is beyond the jurisdiction of Article 25 Tidal Wetlands. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6 NYCRR Part 661), no permit is required for work occurring at the property landward of the jurisdictional boundary indicated above, please be advised, however, that no construction, sedimentation, or disturbance of anj kind may take place seaward of the jurisdictional boundary without a permit, It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within the DEC's jurisdiction which may result from your project. Such precautions may include maintaining an adequate work area (i.e. a 15' to 20' wide construction area) or erecting a temporary fence barrier, or hay bale berm. Please be further advised that this letter does not relieve you of th sponsibility of obtaining any necessary permits or approvals from other age ies, ery tr your „ J hn iel er It Adml or CC Michael Macrina Architect, P.C. Marine Habitat Protection File NEVYIDart 0epartmentof S it Environmental Conservation BOARD OF SOUTHOLD TOWN TRUSTEES SOUTHOLD,NEW YORK PERMIT NO.9738 DATE: OCTOBER 28,2020 ISSUED TO: RACHEL MURPHY PROPERTY ADDRESS: 21695 SOUNDVIEW AVENUE SOUTHOLD SCTM#1000435-1-7' AUTHORIZATION Pursuant to the provisions" of Chapter 275 of the Town Code of the Town of Southold and in accordance with the Resolution of the Board of Trustees adopted at the meeting held ontb 29.2020, and in consideration of application fee in-the sum of$250.00 paid by Rachel MuMhhy and subject to the Terms and Conditions as stated in the Resolution, the Southold Town Board of Trustees authorizes and permits the following: Wetland Permit to demolish existing dwelling and porches,detached garage,shed,cesspool,walks, driveway and air conditioning units; construct a proposed two-story framed 4,178sq.ft.(59'x40' irregular)dwelling with 1,100sq.ft.attached wrap around porch with steps to grade;a proposed 416sq.ft. (16'x261)attached garage; proposed 314sq.ft.(13'x23.3')roof deck over side porch; proposed 140sq.ft. (13'x9.51)roof deck over garage; proposed 85sq.ft.(17'x5')basement stair; proposed 35sq.ft.(71x5') egress window well; proposed 185sq.ft.(21.4'xS.71)uncovered impervious patio-rear side; proposed 935sq.ft.(40.11x45.5' irregular)uncovered impervious patio-left side; proposed steps to grade from porch;proposed 480sq,ft.(16100')in-ground swimming pool; proposed 4'x10'pool equipment area (pump,filter& heater); proposed two(2)31x3'air conditioning units; proposed 3'x5'standby generator; proposed UA septic system; proposed 2,750sq.ft.gravel driveway; two(2)proposed drywells for house, patios&pool; a proposed 4'high compliant pool enclosure fencing; and to install and perpetually maintain a 10' wide non-turf buffer along the landward edge of the top of the bank; and as depicted on the survey prepared by Metes and Bounds Surveying,last dated October 16,2020,and stamped approved on October 28,2020. IN WITNESS WHEREOF,the said Board of Trustees hereby causes its Corporate Seal to be affixed, and these presents to be subscribed by a majority of the said Board as of the 28`h day of October,2020. FRk w_.. �:.:.....w� - � aa app re��vmvaea x�' � .Pd... �# q F.ae +ara"e�arsftta''u tC�✓� t2 !&" XPBGdx�',✓u'.4p�W✓A' mrtttW�v Glenn Goldsmith,President QsoTown Hall Annex Michael J.Domino �3� 54375 Route 25 John M.Bredemeyer IIIAL IAL P.O.Box 1179 " Southold,New York 11971 A.Nicholas Krupski Telephone (631) 765-1892 Greg Williams , ►p Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD October 29, 2020 Michael Macrina Architect P.C. 21 Main Street Stony Brook, NY 11790 RE: RACHEL MURPHY 21695 SOUNDVIEW AVENUE, SOUTHOLD SCTM# 1000-135-1-7 Dear Mr. Macrina: The Board of Town Trustees took the following action during its regular meeting held on Wednesday, October 28, 2020 regarding the above matter: WHEREAS, Michael Macrina Architect P.C., on behalf of RACHEL MURPHY applied to the Southold Town Trustees for a permit under the provisions of Chapter 275 of the Southold Town Code, the Wetland Ordinance of the Town of Southold, application dated September 30, 2020, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council and to the Local Waterfront Revitalization Program Coordinator for their findings and recommendations, and, WHEREAS, the LWRP Coordinator recommended that the proposed application be found Inconsistent with the LWRP, and, WHEREAS, the Board of Trustees has furthered Policy 4.1 of the Local Waterfront Revitalization Program to the greatest extent possible through the imposition of the following Best Management Practice requirements: proposed structures have been moved out of the Coastal Erosion Hazard Area; and WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on October 28, 2020, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the Board members have personally viewed and are familiar with the premises in question and the surrounding area, and, 2 WHEREAS, the Board has considered all the testimony and documentation submitted concerning this application, and, WHEREAS, the structure complies with the standards set forth in Chapter 275 of the Southold Town Code, WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT, RESOLVED, that for the mitigating factors ,and based upon the Best Management Practice requirement imposed above, the Board of Trustees deems the action to be Consistent with the Local Waterfront Revitalization Program pursuant to Chapter 268-5 Of the Southold Town Code, and, RESOLVED, that the Board of Trustees approve the application of RACHEL MURPHY to demolish existing dwelling and porches, detached garage, shed, cesspool, walls, driveway and air conditloning units; construct a proposed two-story framed 4,178sq.ft. (58'x40' irregular) dwelling with 1,100sq.ft. attached wrap around porch with steps to grade; a proposed 416sq.ft. (16`x26') attached garage; proposed 814sq.ft. (13'x23.3') roof deck over side porch; proposed 140sq.ft. (13'x9.5") roof deck over garage; proposed 85sq.ft. (17'x5') basement stair, proposed 35sq.ft. (7'x5°) egress window well;. proposed 185sq.ft. (21,4x8.7') uncovered impervious patio-rear side; proposed 935sq.ft. (40.1'x45.5' irregular) uncovered impervious patio-left side; proposed steps to grade from porch; proposed 480sq.ft. (16'x30'') in-ground swimming pool; proposed 'x10' pool equipment area (pump, filter& heater); proposed two (2) 3x3` air conditioning units; proposed 3'x5' standby,generator; proposed I/A septic system; proposed 2,750sq.ft„ gravel driveway; two (2) proposed drywells for house, patios pool; a proposed 4' high compliant pool enclosure fencing; and to install and perpetually maintain a 10' wide non-turf buffer along the landward edge of the top of the bank; and as depicted on the survey prepared by Metes and Bounds Surveying, last dated October 16, 2020, and stamped approved on October 28, 2020. Permit to construct and complete project will expire two years from the date the permit is signed. Fees must be paid, if applicable, and permit issued within six months of the date of this notification. Inspections are required at a fee of$50.00 per inspection. (See attached schedule.) Fees: $50.00 V truly yours, lean Ool mith President, Board of Trustees Glenn Goldsmith,PresidentTown Hall Annex Michael J.Domino,Vice-President �' 54375 Route 25 John M.Bredemeyer III P.O.Box 1179 1W Southold,New York 11971 A. Nicholas Krupski csr . Telephone(631) 765-1892 Greg Williams � " r Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Permit No.: 9633A Date of Receipt of Application: January 13, 2020 lw . Applicant: Rachel L. Murphy SCTM#: 1000-135-1-7 Project'Loceition: 21695 Soundview Avenue, Southold Date.of Resolution/Issuance: February 12, 2020 -Date of Expiration: February 12, 2022 Reviewed by.: Michael J. Domino, Vice-President Project Description: For the demolition and removal of house, garage, shed, driveway and walkways. Findings: The project mee'ts`•all the'requirements,for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the survey prepared by Metes and Bounds Surveying dated April 12, 2018 and stamped approved on February 12, 2020. Special Conditions: Haybales and silt fencing are to be installed during demolition. Inspections: Haybale/silt fencing inspection prior to demolition and Final Inspection. If the proposed activities do not meet the requirements for issuance of.an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. Glenn Goldsmith, President Board of Trustees BOARD MEMBERS ► + l Southold Town Hall Leslie Kanes Weisman,Chairperson 53095 Main Road-P.O.Box 1179 Patricia Acampora Southold,NY 11971-0959 Eric Dantes tcc 1; tion: Robert Lehnert,Jr. + , Town Annex/First Floor, �� 54375 Main Road(at Youngs Avenue) Nicholas Planamento , Southold,NY 11971 hap://sou&ol&ownny.gov RECEIVE ZONING BOARD OF APPEALS &F,kA (9 5:15 AM TOWN OF SOUTHOLD JUL 4 2C? Tel.(631)765-1809-Fax(631)765.9064 U. Sty hoId 'To Clerk FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF JULY 18,2019 ZBA FILE: #7295 NAME OF APPLICANT:. Rachael Murphy PROI-'ERTY LOCATION: 21.695 Soundview Avenue, Southold,NY SCTM#1000-135-1-7 SEORA DETE . 'A ION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type 11 category of the State's List of Actions, without further steps under SEQRA. S 1F )1r n was referred as required under the Suffolk County Aufl~olk County Dep ent of,Planning issued its reply dMarch l l3, 2019 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. L M- .INATiON: This application was referred for review under Chapter 269, Waterfront Consistency review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (L P) Policy Standards. The LWRP Coordinator issued a recommendation dated June 24. 2019.. Based upon the information provided on the LiIR.P Consistency Assessment Form,as well as the records, it is recommended that the proposed action is INCONSISTENT with LWRP Policy Standard's; and therefore, INCONSISTENT with the LWRP. However, the Board finds that the application, as amended is CONSISTENT with the recommendations of the LARP policies and is therefore CONSISTENT with the LWRP. The proposed single-family dwelling exceeds the maximum allowable lot coverage in an area subject to frequent coastal storms. In 2009, the Board of Trustees issued a permit for restoration of the bluff that washed-out and eroded as a result of storm damage. Policy 4.1 of the L 'RP provision instructs development, other than water dependent uses, in coastal hazard areas be avoided to minimize potential loss and damage. The coordinator included the following comments and recommendations in his report: The single-family use is not a water dependent use.The construction of a single-family residence further landward that the existing structures,furthers this policy,however, it does not mitigate all risks involved with a major storm.The proposed setback from the tap of the bluff`is proposed at 26.1 feet where 100 feet is required. The small size of the buildable area of the parcel and proposed structure placement coupled with the increase in lot coverage to greater that the 20 percent creates a situation in where the structures are still at risk in a highly vulnerable area. Page 2,July 18,2019 #7295,Murphy SCTM No. 1000-135-1-7 The increase in size(percent cover)of structures is not supported. The closest setback to the CEHA is 2 foot(covered porch). Historical storm events have eroded the bluff seaward of the CEHA line along the Long Island Sound shore even when armored. The proposed location of die structure and increase in structure size in this vulnerable area is highly susceptible to damage and loss over time during times of major storms events including hurricanes. It is recommended that the proposed single-family structure is modified to meet. Chapter 280 lot coverage requirements and maximize the distance from the Coastal Erosion Hazard Area to the extent practicable. In the event that action is approved verify the adequacy of the sanitary system shown on the plan. An I/A OWTS (Advanced I/A Waste Water Treatment System)is recommended.. -UM OL-COUNTY SOI-L—.A I'D WATT CONSERVATION DISTRICT: This application was referred for an evaluation and recommendation to the Suffolk County Soil and Water Conservation District. According to a report from the agency, dated May 30, 2019 which photographs of effected areas, an inspection of the property was conducted on May 22, 2019. At the time of the visit it was observed that the yard landward of the bluff was well vegetated in turf grasses showing no apparent cause for concerns. There was no stairway access to the bluff so a close inspection was not possible. There were obvious erosion issues on the bluff face, and bulkheading that needs some maintenance. It was further noted that the current dwelling rests on the coastal erosion hazard line and is approximately within 10 feet from the top of the bluff at the closest point. The plans to build a new two story home landward of the Coastal Erosion Hazard Line are appropriate for the size of the parcel. Considerations must be made to limit any further erosion on the bluff. Stormwater run-off from the roof must be captured through gutters and leaders and safely infiltrated. Additionally, since this drywell is located in the construction zone where the demolition is to take place, be sure that the structure has the proper infiltration rate and the area has not become overly compacted during deconstruction. The same concern for the installation of the pool, again the drywell for the patio is depicted on the plans but there lacks a description of how the drywell is to be used. There is no statement that this drywell will capture pool discharge or be setup for emergency'or maintenance pool draining. No water should ever crest over the bluff. The bluff is deteriorated and requires mediation. There are stormwater conveyance pipes directly discharging onto the bluff. This has caused significant sliding/sloughing to occur. The bluff also severely lacks vegetation creation increased risk for failure, and will require regrading to the natural angle of repose,followed by stabilization,and revegetation. PROPE-RTY FA 1aESC _LQl L- 'The subject property located is a conforming 44,014 square foot lot located in the R-40;honing District. The northerly property line measures 217 1.0 feet adjacent to I ong.Island Sound. The easterly property line measures 240.00 feet and the southerly property lines measure 148.84 feet adjacent to Soundview Avenue and the westerly property line measures 253.00 feet. ,Presently, there is a two-story dwelling and a two-car garage that will be demolished. There are existing stone walls and stone stairs that lead to Long Island Sound from the top of the Bank and a concrete seawall along with wood bulkheading. All as shown on the survey map prepared by Metes and Bounds Surveying, Ralph O, Heil, LS., last revised April 12, 2018 to indicate the Coastal Erosion Hazard Line. ISI PI' ICAT�IOII: Requzst for Variances from Article Iii, Sections 280-15; Article IV, Section 280-18; Article XXII, Section 280-116A(1), and the Building Inspector's February 14, 2019, Notice of Disapproval based on an application for a. building permit to demolish and existing single family dwelling and construct a new single family dwelling and an accessory in-ground pool; at; 1) proposed swimming pool located in other than the code required rear yard; 2) proposed construction is more than the code permitted maximum lot coverage of 20%; 3) proposed construction of the single family dwelling is located Iess than the code required 100 feet from the top of the bluff;at: 21695 Soundview Avenue, Adj. to the Long Island Sound,Southold, NY. SSC"I`N4 1000-135-1-7. Page 3,July 18,2019 #7295,Murphy SCTM No. 1000-135-1-7 RELIEF REQUESTED: The applicant requests variances to demolish an existing single-family dwelling and detached garage and to construct a new single-family dwelling with an attached garage and an accessory in-ground swimming pool. The relief requested is to construct the dwelling 26.1 feet from the top of the bluff where a 100 foot minimum setback is required, locate the accessory swimming pool in the side yard where accessory structures are only permitted in the rear yard or front yard for waterfront properties,and a lot coverage to 22.2%where a total maximum of 20%is allowed. E1DED AI'P"LICATI1 : During the hearing,the applicant was asked to bring the plan into more conformity with the code. The applicant on July 15,2019 submitted a survey prepared by Ralph O.Heil,L.S., last revised July 10, 2019 which depicts an increase in the Top of the Bluff setback from 26.1 feet to 33 feet by reducing the front yard setback by 5 feet applying the "average setback" of the front yard on Soundview Avenue, in conformance with the code.The new revised survey also reduces the proposed lot coverage by decreasing the size of the attached garage (16 feet by 28 feet) and the accessory swimming pool (16 feet by 30 feet) in order to conform to the code pennitted maximum lot coverage of 20%, and no longer requires a variance. The proposed pool is still in a non- conforming side yard and will require a variance AD I'ILONAL INFQ 3ItQN': In 2010,the Southold Town Board of Trustees approved the Amendment to the Wetland Permit#7204 and Coastal Erosion Permit 47204C to authorize the placement of approximately 122 linear feet of 200-300 lb. toe stone and 6 foot wide gravel splash pad landward of the new bulkhead; to establish small berm landward of the top of the bank; and to stabilize backfill before planting with jute matting(anchored by toe stone)and as depicted on the revised site plan prepared by EN-Consultants,Inc.and last dated July 27,2010. Prior to that permit and Emergency Wetlands Permit was issued by the Southold Town Board of Trustees for temporary precast concrete blocks to be place at the toe of the bluff due to storm induced collapse of the existing timber bulkhead (hurricane Sandy) in October 2009. Additionally,the applicant received a Letter of No-Jurisdiction dated May 30,2019 from the NYS Department of Environmental Conservations for proposed improvements,and advised that no work is to be done Iandward of the agency's jurisdictional boundary(CEHL). ; '. .1'�1V. ± :., .A�/ItEASO FOR BCAI AC , IIiC The Zoning Board of Appeals held a public hearing on this application on July 3,2019 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town ,Law 267-b J . Grant of the relief, as amended will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. This is a residential neighborhood with waterfront homes of varying sizes that are all similarly located close to Soundview Avenue to provide maximum setbacks from the bluff. The proposed new dwelling will conform to the code permitted front yard setback by applying the "average setback" of the front yard of adjacent dwellings on Soundview Avenue. Many of the waterfront homes in the neighborhood have non-conforming bluff setbacks and in ground pools are a common amenity. The present residence is located 10 feet from the top of the bluff and within the Coastal Erosion Hazard Line. The proposed new house will be moved landward of the bluff and the Coastal Erosion Hazard line. The application has been amended to remove the need for a lot coverage variance by decreasing the size of the proposed attached garage and the size of the proposed in ground pool. 2. Town Law 267-b 'b 2 . The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The proposed in ground swimming pool in the side yard, on grade, is conforming to the required side yard setbacks and avoids adverse impacts to the bluff. Given the Page 4,July 18,2019 #7295,Murphy SUM No. 1000-135-1-7 reduced front yard setback to locate the new dwelling as far from the bluff as possible,there is no room to locate a pool in a code conforming front yard. The existing dwelling is only 10 feet from the top of the bluff and within the Coastal Erosion Hazard Area, The existing two-story house is 2,194 square feet with a detached garage. The proposed new two-story house will be 2,099 square feet and located outside of the Coastal Erosion Hazard area. The garage will be connected to the house. 3, Town Law 6267-b(3)(b)(3). The variances granted herein are mathematically substantial, representing 67% relief from the code for the setback of the dwelling from the top of the bluff. However,the buildable area landward of the top of the bluff on this parcel is only 20,462 square feet. The existing dwelling to be demolished is only 10 feet from the top of the bluff and within the Coastal Erosion Hazard line and the proposed setback,as amended will be substantially more conforming to the code. The location of the in-ground swimming pool is mathematically substantial,representing 100%. However, it is the only feasible location given the bluff and front yard setbacks. 4. Town Law 6267-b(3)(b)(4). 1qo evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. The new house will be constructed to new energy code and hurricane code standards with proper drainage and an updated IA sanitary system. 5. Town Law 42674(3)(b) . The difficulty his not been self-created. The same family has owned this property prior to changes or adoption of waterfront regulations and the current bulk schedule. The amended application is proposing to increase the degree of code conformance of all proposed now structures on the subject property. 6. Town Law 4267-b. Grant the requested relief is the minimum action necessary and adequate minimum action to enable the applicant to enjoy the benefit of a demolishing the existing home and accessory garage and building a new dwelling with an in ground swimming pool while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community, OL TION OF ITM BC) D: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Aeampora, seconded by Member Planamento, and duty carried,to GRANT the variances as AMENDED and shown on the revised survey map prepared by Metes and Bounds Surveying, Ralph O. Heil,LS, and last revised July 10,2019. S Q_W E,(if TO—T—H E F 0 L L 0 W N G Q0NDnQNS. 1. The applicant shall submit revised architectural elevations and floor plans per the amended application. 2. The applicant shall address SC Soil & Water District concerns relating to Stormwater Management and comply with Chapter 236 of the Town's Storm Water Management Code 3. The applicant shall address concerns by SC Soil and Water District relating to bluff erosion and apply methods for revegetation and stabilization of the bluff, 4. The applicant shall install an Advanced I/A Waste Water treatment system as approved by the Suffolk County Department of Health Services, 5. The applicants shall obtain approvals by the Southold Town Board of Trustees as/if required. 6� Sw_MWM9T a. Pool mechanicals shall be placed in a sound deadening enclosure. b. Drywell for pool de-watering shall be installed. Page 5,July 18,2019 #7295,Murphy SCTM No. 1000-135-1-7 That the above conditions he written into the BuiIdin g Inspector's Certificate cate of Occupancy, when issued Any deviation from the survey, site plan andlor architectural drawings cited in this decision will result in delays andlor apossible denial by the Building Department of a building permit„ and may require a new application and public hearing before the Zoning Board of Appeal , Any deviation from the variance(s)granted herein as shown on the architectural drawings, site plan andlor survey cited above, such as alterations, extensions, or demolitions, an, not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setback and other features as are expressly addressed in this action. In the event that an approval Is granted subject to conditions, the approval shall not be deemed effective until the required conditions have been met; and failure to comply therewith will render this approval null and void. The Board reserves,the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration,grant an extension not to exceed three (3) consecutive one (1)year terms. Vote of the Board: Ayes:Members Weisman (Chairperson), Dantes,Planamento, and Acampora.(4-0)(Member Lehnert Absent) ze A –----- Kanes e4ismann— Chairperson Approved for filing 14� /2019 Southold Town Hall BOARD MEMBERS Leslie Kanes Weisman,Chairperson . i 53095 Main Road • P.O. Box 1179 Southold,NY 11971-0959 Patricia Acampora --Office Location: Eric Dantes ,,fp Town Agnex/First Floor, Robert Lehnert,Jr. 54375 Main Road(at Youngs Avenue) Nicholas PlanamentoSouthold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel.(631) 765-1809 EXTENSION DETERMINATION One Year Extension Regular Meeting of October 6, 2022 ZBA FILE: #7295 NAME OF APPLICANT: Rachael Murphy PROPERTY LOCATION: 21695 Soundview Avenue, Southold, NY SCTM#1000-135-1-7 BASIS OF „I,ICATION` Request for Variances from Article 11I, Sections 280-15; Article IV, Section 280-18; Article XXII, Section 280-116A(1); and the Building Inspector's February 14, 2019,•Notice of Disapproval based on an application for a building permit to demolish and existing single family dwelling-and construct a new single family dwelling and an accessory in-ground pool; at; 1) proposed swimming pool located in other than the code required rear yard; 2) proposed construction is more than the code permitted maximum lot coverage of 20%; 3) proposed construction of the single family dwelling is located less than the code required 100 feet from the top of the bluff, at: 21695 Soundview Avenue, (Adj. to the Long Island Sound, Southold,NY. SSCTM#1000-135-1-7, ( ELIl I RI C}J ` FIry C is The applicant requests variances to demolish an existing single-family dwelling and detached garage and to construct a new single-family dwelling with an attached garage and an accessory in-ground swimming pool. The relief requested is to construct the dwelling 26.1 feet from the top of the bluff where a 100 foot minimum setback is required, locate the accessory swimming pool in the side yard where accessory structures are only permitted in the rear yard or front yard for waterfront properties, and a lot coverage to 22.2% where a total maximum of 20% is allowed. AMENDED I'P K..A.l.ION: During the hearing„ the applicant was asked to bring the plan into more conformity with the code, The applicant on July 15, 2019 subp°spitted a survey prepared by Ralph O. Heil, L.S., last revised July 10, 2019 which depicts an increase in the Top of the Bluff setback from 26.1 feet to 33 feet by reducing the front yard setback by 5 feet applying the "average setback" of the front yarn c n ".c°sun vt'ewavenue, in conformance with the code. The new revised survey also reduces the proliosed lot coverage by decreasing the size of the attached garage (16 feet by 28 feet) and the accessory swimming pool (16 feet by 30 feet) in carder to conform to the code permitted maximum lot coverage of 20%, and no longer requires a variance. The proposed pool is still in a non- conforming side yard and will require a variance l)A l ,OF I'UI I I HEARING: July 3, 2019 This request for a variance was originally Granted as Amended with conditions on July 18, 2019. By email correspondence, dated September 30, 2022, Rachel Murphy, Owner, requested a one-year extension of the Variance Relief. October 6, 2022 Year Extension—#7295 Rachel Murphy RESOLUE10--Of 1HE_1BOARD: A motion was offered by Member Weisman (Chair-person) seconded by Member Planamento, and duly carried,to GRANT the applicant's request that the above cited determination be extended for a one-year period beginning July 18,2,022, and to expire on July 18,2023 as per Chapter 280-146 of the Code of the Town of Southold. B application, 1. The applicant shall submit revised architectural elevations and floor plans per the amended app 2. The applicant -shall address SC Soil & Water District concerns relating to Stormwater Management and comply with Chapter 236 of the Town's Storm Water Management Code 3, The applicant shall address concerns by SC Soil and Water District relating to bluff erosion and apply methods for revegetation and stabilization of the bluff. 4. The applicant shall install an Advanced UA Waste Water treafment system as approved by the Suffolk County Department of Health Services. 5, The applicants shall obtain approvals by the Southold Town Board of Trustees as/if required. 6. Swirninin J (IQLC Pd(i.tions: a, Pool mechanicals shall be placed in a sound deadening enclosure. b. Drywell for pool de-watering shall be installed. Vote of the Board: Ayes: Members Weisman (Chairperson), Dantes, Planamento and Acampora, and Lehnert. This Re oiution was duly adopted(5-0), Leslie Kanes Weisman Approved for filing /,/j/ 7 /2022 OCTOBER 18, 2017 5„ RVEY OF _W ._QQY_E Ac MARCH 30, 2018 - ADD PROPOSED HOUSE landward to top of bank APRIL 12, 2018 - ADD COASTAL EROSION HAZARD LINE PROPERTY (area = 20,462 SF) SEPTEMBER 25, 2018 - ADD ATTACHED GARAGEy , SITUATE r PROPOSED JANUARY 23, 2019 - MISC. REVISIONS VILLAGE OF SOUTHOLD COVERAGEBREAKDOWN JULY 10, 2019 - AS PER ZBA COMMENTS TOWN OF SOUTHOLD HOUSE = 2,099 SF SEPT. 29, 2020 - AS PER TRUSTEES COMMENTS SUFFOLK COUNTY, NEW YORK GARAGE = 416 SF OCT. 16, 202D - AS.PER TRUSTEES SITE VISIT S.C. TAX No. 1000-135-01 -07 COVERED PORCH = 1,100 SF POOL = 480 SF __.................__......_........... DliA1NAGpak f'EM.,,CALCULAa'ION_rS.` SCALE 1"=30' TOTAL COVERAGE = 4,095 SF ROOF AREA: 3,615 sq. ft. - REAR PATIO AREA: 185 sq. ft. -” 4,095 SF 20,462 SF = .200 SIDE PATIO AREA: 935 sq. ft. ^ `O PROPOSED LOT 4,735 sq. ft. X 0.17 = 805 cu. ft. 2 \ COVERAGE = 20.0% (conforms) 805 cu. ft. / 42.2 = 19,1 vertical ft. of 8' dia, leaching pool required landward to top of bank PROVIDE (2) 8' dia. X 12' TALL STORM DRAIN POOLS, to be wrapped with filter fabric 0 0 A° CIO., N � o LONG ISLAND SOUND 00 lS� 9 t 0 P j 0 NC. 67" HIGH WATER ALONG WOOD BULkHL� EAD SEAWALL �, CONC SEAWALL 11 3 BOTSO'M ar ESANk - I .. 15 0'.s 11 1H EXISDI / I� fcN'py eaNX 12 1.i ` - -Y .4 SE WAIAS � ED• ,�.� -aAXT?K 1(EtnaxT'I �/ � STEPS, 1C _. Gk ^'0 ,kltLF 0YI 14 � 4-- TOB ` 16 17 t e fLl T'aP�t ,,r?fl_,..=„„;. w°., `I PROs D ro'a�V ,,-- t,H. '71'a c EHa.(PATIO ar GRADE) 6 2a ,""N"n"'� I ter. I I NriN 1�Ill.IFx`6'R x'N+,V4U (POOL) ZONE UF. 1 mmn gym' „ "" r`x dk.11 I . t ( � 12Z 1 C.E.H.L. POOL LONE X '" EyT,._1 �+.� E've;,, 4?61CX, AZAR[?G{T#E of ,y, �•j TRENCH V}pgy}Tpp At..�-- ly /2T ,,:PRDPOSED OFT TALL PROP aS6 a Ppµ'@ TO tU fl L4J.w7..U1 9 M T, » d IC'�'iSP M1yO� POOL COMPLIANT FENCE W ,.-.•`• 61N11pWC l8P]0 ' .d YI TING 2 'QRY 1 dM f Q4 S EE2S' >� rrzalHr -IOUIE P421,0 e67dTkl OTW1E13E t II F FMO 12CF_ Sfs parceFL1 �n d n� � �\•"� O" 2'1.11 DRYWELL f 2 FOR HOUSE PsnPATO A// roR siz POOL BACKWASHGEORGE VASILAKIS R PATIO Lfed1 PORCH „ Ppm NYQHND Ni, k l 1 _------- __.._ � N P� ` m n G P, (a Er, t nM 4,', /CE 9 4 z T T i /ar. "CR LOT 6 31.8' , AnA4F a � 1P reaurr� "-PROPOSED an TALL FRONT YARD aE7 ( a 'Fzls ,oN ra POOL COMPLIANT FENCE �RASF- RACK aT tr Ne 19.C1 ,�e PROPOSED UNFAR LOT #� �8 6 ix.NoacH To N Pcscl f e C. EL ig a� '�"T �` TRENCH DRAIN TO DE i 1 F YRpR µ'D # ' PIr�O 10 DRYwtL M2 LOl #4 -- NO STRUCTURES DE REMOVED SPE=t9S T 1 eaa u� �1 # za7a LOT y�, eA �H tec a.. LOT #9 31ZLOT #2 9i Cls E ies d ` n u To>.;a E s. LOT #10 2.4 e p w + "d�o.uSRosEn` �'' '. E"A.sPUT eENCE va '` tl jJ YS LOT #11 ..._6:'�......... L ,. ,..,. `te a WAY J T aAt� " -,ir ,.�. oFPn.' v+s TOTAL 201.5 ,.16 4 H ., �� ,L- Ar E i° 0, . s N. 614 AREA Er 201.5/8 25.2' AF.-- oc)"Pa''IE'TAEN'T �.....Y. ....-.._17 � S A deeded property line 44,014.1 sq. ft. 1.010 ac. r%i�` fr zu e i`a _...._... - -- -._. 18 landward t0 top Of bank = HYDRANT 19Ao cvNri WATER METER I..1...�.9 20,462 sq. ft. S 0.47 ac. SPOT LIGHT p GAS VALVE N SUDSSURFO/C En ONS UTILITIESD AN/OR EXISTENCE UCTURES ) s It e DRYW ELL NOT READILY VISIBLE,ARE NOT CERTIFIED. .. 1 .. `.......,• THIS \4 OflNOOFD AND IS SUB)CCTHER T TO AND( EMENT i METES AND BOUNDS SURVEYING wOF ,T SRC„MD DISC.LDSE 553 PROBS f DHIVL 'IINAIIiVIOflIZEO—RATOI OR Adorn.To A f SSR MAP B—No A IICENS LAND SURVEYOR'S SHIRLEY, NY 11967 w s wTDN Rno.I�<,Dr—n i l 0109,,�Do LiON 2,OF—N.YORK STALE til v PHONE (516) 972-5812 Doc»DN surveydude@optonline.net caPee from the",goal of the aarrey­P j'•. T, net mmkad with on a.YD..he of tbd Vhl aa %”,Inkud weal a he ambaaond neoi j LOTS: 07 BLOCK: 01 SECTION: 135 DISTRICT: 1000 :haflu oat Da aornldorod a 1.11d Noe,copy.' 9 ---------------------- C rtif4 w on Ind dot di hes'aan rignify that NOTF,S: MAP OF: thin sanay wasCodawa Prad m aaordarae with -- the existing of Practice for Land Surveys adopted by the New York State Association of 1. ELEVATIONS ARE REFERENCED TO N.A.V,D. 1988 DATUM _.__..__..__........._....__....................................... Prareaeland Lord sa oras. Said SITUATED AT: HAMLET OF SOUTHOLD cernrcanors enau run only to the Pereon EXISTING ELEVATIONS ARE SHOWN THUS: „GO.GO TOWN OF SOUTFiOLD, SUFFOLK CO., N.Y. far when the Sa,.y is PreParad,and an me behalf to the title company,governmental PROPOSED ELEVATIONS ARE SHOWN THUS: ............-...`.�`�"'..........._............................_................................._..._...�...._—__........._.____._,......_....... o9en<y and lending mamatmn. F1.19.D Cerlifimti-a are not tronsferahie to drat_.. additiansl institutions or subse t owners." Michael & Rachel Murphy 9Oe" 2. FLOOD ZONE INFORMATION TAKEN FROM: CERTIFIED -'m'm'-----------------"----""-'-----' ------'—�_._,._._ ...—..__...... FLOOD INSURANCE RATE MAP No. 3610300158 H TO ..............................................................----------.............................................. J013 NO.:._-__17-293...--.-..-. ZONE X: BASE FLOOD ELEVATIONS DETERMINED """"""""""""""""..... '---"'--- --"""""'--LL-" DATE: OCTOBER 18, 2017 SWIMMING POOL ENCLOSURE NOTES: 12" OVERHEAD CONDUCTOR CLEARANCES SWIMMING POOL ENCLOSURES SHALL CONFORM TO THE 2020 CHANNEL TRACK FOR AUTO-COVER NEW YORK STATE RESIDENTIAL CODE INSULATED SUPPLY OR SERVICE DROP CABLES, ALL OTHER SUPPLY OR SERVICE APPLICATION. The provisions of this chapter shall control the '-0" 30'-0" 1'-O" 0-750 VOLTS TO GROUND, SUPPORTED ON AND DROP CONDUCTORS feet CABLED TOGETHER WITH AN EFFECTIVELY GROUNDED VOLTAGE TO GROUND the design of barriers for residential swimming pools, spas and hotJ BARE MESSENGER OR EFFECTIVELY GROUNDED 0 - 15k GREATER THAN tubs. These design controls are intended to provide protection against NEUTRAL CONDUCTOR (feet) 15 TO 50kV potential drownings and near-drownings by resticting access to c : �' A: CLEARANCE IN ANY DIRECTION swimming pools, spas and hot tubs. WATER LINE � TO THE WATER LEVEL EDGE OF TEMPORARY BARRIERS. An outdoor swimming pool, including LT WATER SURFACE, BASE OF DIVING 22.5 25 27 including an in-ground, above-ground or on-ground pool, hot tub or PLATFORM, RA PERMANENTLY- spa shall be surronded by a temporary barrier during installation or ° ° ANCHORED RAFT construction and shall remain in place until a permanent barrier in " A: CLEARANCE IN ANY DIRECTION compliance with Section R326.4.2 is provided. s" x s" TILE FACING COPING EL 0-0 • .a TO THE DIVING PLATFORM 14.5 17 18 Exceptions: BOND BEAM TIES 0 12" o.c. 1. Above -ground or on-ground pools where the pool structure a° is the barrier in compliance with Section 326.4.2.9 2. Spas or hot tubs with a safety cover which complies with (3) #3 BARS CONT. v CAI R ° o I I STEP EL � a ASTM F 1346, , provided that -0'-6" such safety cover is in place during the period of installation o I I SUN DECD ' or construction of ;such hot tub or spa. The temporary SEE SCHEDULE FOR REINFORCING removal of a safety cover as required to facilitate the STEEL SIZE & SPACING M I I P P p PIS 2" C R o installation or construction of a hot tub or spa during periods a • X ^ EL -3'-s" when at least one IDerson engaged in the installation or ° A o N °: ^ � construction is present is permitted. I 1 HEIGHT. The top of the temporary barrier shall be at least I I 6'-6" ~ 48 inches above grade measured on the side of the barrier which ISO MARBLE DUST FINISH I 1 io faces away from the swimming pool. .° . 1 I CI J �i MAIN DRAINS Replacement by a permanent barrier. A temporary ° 6 t. � 0 1 I W b barrier shall be replaced by a compfing permanent barrier within ° U 1 =11 either of the following periods: a s o I I 0 1. 90 days of the date of issuance of the building permit for o I I 3 DRAIN the installation or construction of the swimming pool; or R U)2. 90 days of the date of commencement of the installation ° a I I o 0 or construction of the swimming pool. I I00o Replacement extension. Subject to the approval of the d o I 1'-0" 8'-0" code enforcement official, the time period for completion of the y� permanent barriermay be exrended for good cause, including, but not •° ' yo limited to, adverse weather conditions delaying construction. Al v JF�a P��C,� OUTDOOR SWIMMING POOL. An outdoor swimming pool, including \oma ti�P� an in-ground, above-ground or on-ground pool, hot tub or spa shall ° �P �Q be surrounded by a barrier which shall comply with the following: ti`' R ° ' . COPING EL 0'-0" b 1. The top of the barrier shall be at least 48 inches above #3 STEEL REINFORCING grade measured on the side of the barrier which faces away DEPTH LESS THAN MORE THAN ° PLAN VIEW NOTE: from the swimming pool. The maximum vertical clearance 5-0" 5-0" NO SCALE CONTRACTOR SHALL CHECK POOL LOCATION between grade and the bottom of the barrier shall be 2 inches HORIZ. 12" O.C. 12 o.c. a & ORIENTATION ON SURVEY PRIOR TO EXCAVATION. THIS DATA IS DETERMINED BY THE CONTRACTOR measured on the side of the barrier which faces away from VERT. 12' o.c. 6' o.c. &OWNER. NOTE: the swimmingpool. Where the to of the pool structure is d d EXCESS FILL TO BE CARTED TO LEGAL FILL SITES P P P na : POOL MUST MEET ZONING SETBACKS THESE DIG DIMENSIONS COMPLY WITH THE NATIONAL SPA AND POOL t�' above rade, such as an above- round pool, the barrier may BOTT. 12" o.c. EACH WAY 9 g P � Y : PERMIT IS SUBJECT TO FIELD INSPECTIONS INSTITUTE SUGGESTED MINIMUM STANDARDS FOR RESIDENTIAL POOLS. be at ground level, such as the pool structure, or mounted on v VERIFY LOCATION OF OVERHEAD WIRES AS PER WARNING - DO NOT DIVE IN THE SHALLOW END. t.Ij r ltirl top of the pool structure. Where the barrier is mounted on top NATIONAL ELECTRIC CODE AND PSE&G REQUIREME14TS IF DIVING BOARDS OR SLIDES ARE TO BE USED WITH THIS POOL, of the pool structure, the Barrier shall comply with section R326.4.2.3 PLEASE CONSULT THE NATIONAL SPA AND POOL INSTITUTE'S MINIMUM I• and R326.4.2.3 STANDARDS PRIOR TO INSTALLING DIVING BOARDS OR SLIDES ON THIS POOL FOR INFORMATION CONCERNING NSPI MINIMUM STANDARDS WRITE: NOTE: NATIONAL SPA AND POOL INSTITUTE 2. Openings in the barrier shall not allow passage of a 4-inch- 2111 EISENHOWER AVE. diameter sphere. TYPICAL W 1. SWIMMING POOL DRAINS SHALL COMPLY WITH THE 2020 RCNYS ALEXANDRIA, VA 22314 R326.6.4 (703) 838 - 0083 POOL CONSTRUCTION SHALL CONFORM TO THE 2020 NYS 3. Solid barriers which do not have openings, such as a masonry RESIDENTIAL CODE or stone wall, shall not contain indentations or protrusions eoints.xcept for normal construction tolerances and tooled masonry SECTION B B 30'-0" 4. Where the barrier is composed of horizontal & vertical members NO SCALE 6'-6" and the distance between the tops of the horizontal members REINFORCING is less than 45 inches, the horizontal members shall be located on the swimming pool side of the fence. Spacing between POOL NOTES AUTOMATIC SKIM ER sCHED LE) INLET between vertical members shall not exceed 1 3/4 inches in INLET width. Where there are decorative cutouts within vertical members, 1: CONTRACTOR TO MAINTAIN A TEMPORARY CONC. PA o CAL NOTES BARRIER AROUND THE POOL AREA UNTIL A spacing within the cutouts shall not exceed 1 3/4 inches in width. ELECTRIz : : ' :'•'r. �,' PERMANENT BARRIER IS INSTALLED. SEE Q �~ 5. Where the barrier is composed of horizontal & vertical members ALL ELECTRICAL WORK SHALL TO BE DONE BY BARRIER NOTES FOR SPECIFICATONS AUTO COVER W `.QU 2: ENTRAPMENT PROTECTION FOR POOL AND MECHANISM and the distance between the tops of the horizontal members is A LICENSED ELECTRICAN IN STRICT ACCORDANCE SPA SUCTION OUTLETS z3 45 inches (1143 mm) or more, spacing between vertical members WITH THE LATEST PROVISIONS OF THE NATIONAL UNDERWATER LIGHT �z �z shall not exceed 4 inches. Where there are decorative cutouts ( ) SUCTION OUTLETS SHALL BE DESIGNED TO ELECTRICAL CODE NEC ,NYS RESIDENTIAL CODE (OPTIONAL) o JO io = 3 '' "'"' '• PRODUCE CIRCULATION THROUGHOUT THE POOL I a� I o 1p ...� Ownership and use of Documents Drawings and CHAPTER 41 AND ALL LOCAL CODES HAVING oke o s ecificatons as instruments of g within vertical members, spacing within the cutouts shall not exceed JURISDICTION AS IF FULLY CONTAINED IN THESE AND SPA. SINGLE-OUTLET SYSTEMS , SUCH AS a a P professional service , are and shall remain the property of the Architect. These documents shall not be used in art or whole , for an 1 3/4 inches in width. AUTOMATIC VACUUM CLEANER SYSTEMS, OR Z3 -3 P p y / NOTES. ALL MATERIAL SHALL BEAR THE MULTIPLE SUCTION OUTLETS, WHETHER ISOLATED MA M P Y UNDERWRITER'S LABEL. • other project or purpose, by any other parties than those 6. Maximum mesh size for chain link fences shall be a 2 1/4 inches ELECTRICAL CONTRACTOR SHALL PROVIDE AN BY VALVES OR OTHERWISE, SHALL BE LE authorized by contract, without the written authorization of q P PUNDERWRITER'S OR AN ANOTHER APPROVED PROTECTED AGAINST USER ENTRAPMENT. SLOPE square unless the fence is provided with slats fastened at the to the Architect of Record. or the bottom which reduce the openings to not more than 1 3/4". 3: SUCTION OUTLETS SHALL BE DESIGNED AND MAIN DRAIN It is a violation of the law for an person, unless actin INSPECTING AGENCY CERTIFICATE FOR ALL NEW INSTALLED IN ACCORDANCE WITH THE TYP OF 2 under the direction of a licensed Arh Architect to alter an item INSTALLED. REQUIREMENTS OF CPSC 15 USC8003 AND G E N E R A L N 0 T E S 36" MIN APARTon the drawing in any way. If an item has been altered, 7. Where the barrier is composed of diagonal members, such as a ALL ELECTRICAL OUTLETS AND FIXTURES ANSI APSP ICC 7 WHERE APPLICABLE 4: POOL lattice fence, the maximum opening formed by the INSTALLED THE AREA EXTENDING BETWEEN / / the altering Architect shall affix his seal to the alteration diagonal members shall not be more than 1 3/4 inches FILL LINE SHALL HAVE A BACK-FLOW 1. CONTRACTOR SHALL CHECK & VERIFY ALL CONDITIONS AT THE and note "altered by" followed,by his signature and date of 5'-0" & 10'-0" FROM THE INSIDE WALLS OF PREVENTION VALVE SITE PRIOR TO STARTING THE WORK. 8. Gates shall comply with the requirements of Section R326.4.2.1 through POOLS AND HOT TUBS SHALL BE PROTECTED BY 4: POOL AND SPA SUCTION OUTLETS SHALL the alteration. R326.4.2.6 and with the following requirements: GROUND FAULT CIRCUIT INTERRUPTERS EXCEPT HAVE A COVER THAT CONFORMS TO ANSI/ASME 2. CONTRACTOR OR OWNER SHALL OBTAIN A BUILDING PERMIT FROM WHERE SUCH FIXTURE AND OUTLET ARE Al 12.19.8 OR AN 18" x 23" DRAIN GRATE OR THE LOCAL TOWN OR VILLAGE PRIOR TO STARTING ANY WORK. 2'-t0Y 8.1 All gates shall be self-closing. In addition, if the gate is a INSTALLED NOT LESS THAN 5'-0" ABOVE MAX LARGER OR AN APPROVED CHANNEL DRAIN O O pedestrian access gate, the gate shall open outward, away from WATER LEVEL AND ARE RIGIDLY ATTACHED TO SYSTEM. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS the pool. THE STRUCTURE. 5: ATMOSPHERIC VACUUM RELIEF SYSTEM CERTIFICATE OF COMPLETION/OCCUPANCY, INSPECTION GU1�T1Z'S C1JG]FOOL 8.2 All gates shall be self-latching, with the latch handle located UNDERGROUND WIRING SHALL NOT BE INSTALLED REQUIRED; POOL AND SPA SINGLE OR APPROVALS, ETC. FOR WORK PERFORMED, FROM AGENCIES STA%k4DIAPM within the enclosure (i.e, on the pool side of the enclosure) and UNDER OR WITHIN THE AREA EXTENDING5'-O" MULTIPLE-OUTLET CIRCULATION SYSTEM SHALL HAVING JURISDICTION THEREOF. by at least 40 inches above grade. In addition, if the latch handle is HORIZONTALLY FROM THE INSIDE WALLS OF BE EQUIPPED WITH ATMOSPHERIC VACUUM SECTION " A A " SIZE (FT) A B C D E F G AREA CAPACITY located less than 54 inches from the bottom of the gate, the POOLS AND OUTDOOR HOT TUBS EXCEPT WHERE RELIEF SHOULD GRATE COVERS LOCATED THERIN 4. ALL MATERIAL TO BE USED ON THIS PROJECT SHALL BE rr_w�ro POOLS, INC. latch handle shall be located at least 3 inches below the top of THE WIRING IS INSTALLED TO SUPPLY POOL, SPA, BECOME MISSING OR BROKEN. THIS VACUUM INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURERS 16 x 30 16 30 8 8 14 4 8 576 20220 �► the gate, and neither the gate nor the barrier shall have any HOT TUB EQUIPMENT OR WHERE SPACE RELIEF SYSTEM SHALL INCLUDE AT LEAST ONE RECOMMENDED SPECIFICATIONS FOR INSTALLATION OF THEIR NO SCALE LIMITATIONS PREVENT WIRING FROM BEING ROUTED APPROVED OR ENGINEERED METHOD OF THE PRODUCT. NOTE: s0. FT. GALLONS opening greater than 1/2" within 18" of the latch handle. . 5 -0 FROM THE INSIDE WALLS. WHERE TYPE SPECIFIED HEREIN AS FOLLOWS:' " 5. THE DESIGN IS BASED ON A DRAINAGE SOIL WITH LESS THAN THERE SHALL BE NO ELECTRIC SERVICE WIRES 8.3 All gates shall be INSTALLED WITHIN 5-0OF THE INSIDE WALLS 1) SAFETY VACUUM RELEASE SYSTEM OVERHEAD OR BURIED WITHIN 10'-0' OF POOL Chwn lI securely locked with a key, combination or other � child-proof lock :sufficient to prevent access to the swimming pool THE WIRING METHOD SHALL BE A COMPLETE CONFORMING TO ASME A112.19.17; OR 10% SILT. CONTRACTOR SHALL CONFIRM THIS. through such gate when the swimming pool is not in use or RACEWAY SYSTEM OF RIGID CONDUIT BURIED MIN 2) AN APPROVED GRAVITY DRAINAGE SYSTEM. 6. GROUND WATER SHALL NOT EXIST WITHIN THE LIMITS OF THE C Murphy 18 BELOW GRADE 6: DUAL DRAIN SEPARATION; SINGLE OR supervised. EXCAVATION. IF GROUND WATER DOES EXISTS WITHIN 6'-0" ALL COMPONENTS OF POOL, SPA AND HOT TUB MULTIPLE PUMP CIRCULATION SYSTEM HAVE A 21695 Sovad�im Avees 9. Where a wall or walls of a dwelling may serves as part of the barrier SHALL BE BONDED TOGETHER USING SOLID MIN OF 2 SUCTION OUTLETS OF THE APPROVED BELOW GRADE, SPECIAL DEWATERING FACILITIES WILL BE N.Y. 11971 provided that the wall or walls meet the applicable barrier requirements COPPER CONDUCTORS NOT SMALLER THAN 8 TYPE. A MIN HORIZONTAL OR VERTICAL DISTANCE REQUIRED. of sections R326.4.2.1 through R326.4.2.6 and following conditions shall AWG. OF 3'-0" SHALL SEPARATE THE OUTLETS. be met. ALL LIGHTING, POOL EQUIPMENT ASSOCIATED THESE SUCTION OUTLETS SHALL BE PIPED SO 7. WATER DISPOSAL IS LIMITED TO OWNER'S PROPERTY. 9.1 The pool shall be equipped with a powered safety cover in WITH THE POOL CIRCULATION, JUNCTION BOXES, THAT WATER IS DRAWN THROUGH THEM 399,000 GAS COCK WITHIN „ HAIR & LINT compliance with ASTM F1346; or TRANSFORMER ENCLOSURES, GFI AND PANEL SIMULTANEOUSLY THROUGH A VACUUM RELIEF 8. NO SURCHARGE ALLOWED WITHIN 4'-0' OF SHALLOW END AND BTU UNION 6'-0" FROM 1 1/2 WASTE CATCHER K% BOARDS NOT PART OF THE SERVICE EQUIPMENT PROTECTED LINE TO THE PUMP OR PUMPS. 6'-0" OF DEEP END. HEATER POOL HEATER FILTER 9.2 Doors with direct access to the pool through that wall shall be AND THAT SUPLY ANY ELECTRICAL EQUIPMENT 7:POOL CLEANER FITTINGS; WHERE PROVIDED, 6311.4254-0057 equipped with an alarm which produces an audible warning when the ASSOCIATED WITH THE POOL, HOT TUB OR SPA VACUUM OR PRESSURE CLEANER FITTINGS 9. THE PNEUMATICALLY APPLIED CONCRETE (GUNITE) SHALL BE GAS HEATER �4 door and/or its screen, if resent are opened. The alarm shall be SHALL BE GROUNDED. SHALL BE LOCATED IN AN ACCESSIBLE POSITION A 1:4 MIX WITH A MAXIMUM OF 3 1 2 GALLONS OF WATER PER VALVE / P P / REDUCER PUMP Berew• listed in accordance with UL 2017. The audible alarm shall POOLS AND AREA EXTENDING 10'-0" AT LEAST 6" AND NOT MORE THAN 12" BELOW SACK OF CEMENT. GRADE GRADE � P. activate within 7 seconds & sound continuously for a minimum of HORIZONTALLY FROM THE INSIDE FACE OF THE MIN OPERATIONAL WATER LEVEL OR AS AN A r c h i it C-_ c t 30 seconds after the door and/or its screen, if present, are WALLS, DIVING STRUCTURES, OBSERVATION ATTACHMENT TO THE SKIMMERS 10. REINFORCING STEEL SHALL BE INTERMEDIATE GRADE BILLET RISER WATER LINE opened & be capable of being heard throughouy the house during STANDS, TOWERS AND PLATFORMS SHALL NOT 8: POOL SHALL BE HAVE A MEANS OF EGRESS STEEL WITH A MINIMUM LAP OF 30 BAR DIAMETERS. GAS LINE FROM METER 14 Cors,Street, Dix Hills, NY 11746 normal household) activities. The alarm shall automatically reset BE PLACED UNDER SERVICE DROP CONDUCTORS FROM BOTH DEEP AND SHALLOW END . GAS LINE FROM METER SEE NOTE FOR SIZE SKIMMER under all conditions. The alarm system shall be equipped with OR ANY OTHER OPEN OVERHEAD WIRING. 9: POOL HEATERS SHALL BE PROVIDED WITH 11. POOL WATER SUPPLY SHALL BE FROM OWNER'S GARDEN HOSE. LENGTH SIZE 2" with manual means, such as touc pad or switch, to temporarily ELECTRICAL CONTRACTOR SHALL COORDINATE TEMPERATURE AND PRESSURE RELIEF VALVE. POOL TO BE KEPT FULL DURING FREEZING WEATHER, PUMP „ 2 RETURN TO INLET deactivate the alarm for a single opening. Deactivation shall last 10: POOL MUST BE EQUIPPED WITH AN 60 -0' OR LESS 1Y4 sem: �� 9 P 9• HIS WORK WITH THE MECHANICAL CONTRACTOR CAPACITY TO BE SUFFICIENT TO EMPTY POOL IN 24 HOURS. '-0"-150'-0" 1 for not more than 15 seconds. The deactivation switch60 switch(es) shall AND SHALL FURNISH AND INSTALL ALL APPROVED ALARM AND COMPLY WITH ASTM , NOTE: 3'-0" AS NO'i�.''D 8-9-2022 be located at least 54 inches above the threshold of the door; or: FEEDERS AND DISCONNECTS TO ALL HEATING F2208(STANDARD SPECIFICATION FOR POOL 12. ALL ELECTRICAL WORK TO BE BOARD OF FIRE UNDERWRITERS 150'-0" OR ABOVE 2" AND AIR CONDITIONING EQUIPMENT. ALL ALARMS) AND SHALL BE INSTALLED, USED AND TIME CLOCKS SHALL BE INSTALLED SO � GAS RISER SCHEMATICMINobNo2 APPROVED. �°"y✓-r��� +;`t`'� �•,< J 2022-10 9.3 Other means of protection, such as self-closing doors with self- THERMOSTATIC AND LOW VOLTAGE WIRING MAINTAINED IN ACCORDANCE WITH THE MANU NO SCALE THAT THE PUMP CAN BE SET TO RUN � latching devices, shall be acceptable o Ion as •the dd r e f SHALL BE FURNISHED AND INSTALLED BY INSTRUCTIONS AND THIS SECTION 13. INFORMATION SHOWN HEREON WAS FURNISHED BY ALCAMO POOLS. protection afforded is not less than The protection of csgrc�edoby MECHANICAL CONTRACTOR AS PART OF HIS 11: A POOL ALARM MUST BE CAPABLE OF IN THE OFF-PEAK ELECTRIC DEMAND MAIN DRAINS /s°s �� • �� SheetNnmbec: DETECTING ENTRY INTO THE WATER AT ANY POOL HEATER NOTES PERIOD AND CAN BE SET FOR THE Item 9.1 or 9.2 described above. WORK. ALL POWER WIRING (110 OR 220 14. ARCHITECT HAS NOT BEEN RETAINED FOR ON SITE OBSERVATION. : IF APPLICABLE AN OPEN TRENCH INSPECTION IS REQUIRED Baa , L'- VOLTS TO UNITS TO UNITS TO BE BY THE POINT ON THE SURFACE OF THE SWIMMING MINIMUM TIME NECESSARY TO <<�.h{ r 9.4 Operable windows in the wall or walls used as a barrier shall have ) POOL. IF NECESSARY TO PROVIDE DETECTION 15. ALL SOIL EXCAVATED DURING THE CONSTRUCTION OF A : GAS LINES REQUIRE A PRESSURE TEST MAINTAIN THE WATER IN A CLEAR ELECTRICAL CONTRACTOR. INSPECTIONS ARE REQUIRED FOR THE OIL POOL HEATER a latching device located no less than 48 above the floor. CAPABILITY AT EVERY POINT ON THE SURFACE SWIMMING POOL MUST BE PROPERLY DISPOSED OF OFF SITE. AND SANITARY CONDITION IN KEEPING THE CONTRACTOR SHALL GUARANTEE ALL WORK OF THE SWIMMING POOL, MORE THAN ONE POOL EXCESS FILL GENERATED FROM THE CONSTRUCTION OF A AND OIL LINES , Openings in operable windows shall not allow a largest sphere pass AND MATERIAL FURNISHED AND INSTALLED TO : PROPANE HEATERS REQUIRE A PERMIT FROM THE FIRE WITH APPLICABLE HEALTH STANDARDS. ------ through the opening when the window is in its lar est o ened ALARM MUST BE INSTALLED. SWIMMING POOL MAY NOT BE USED ON THE PROPERTY UNLESS A 9 P g g P BE FREE OF DEFECTS AND SHALL KEEP SAME 12: NO SOIL SURCHARGE SHALL BE PLACE GRADING AND DRAINAGE PLAN IS SUBMITTED REVIEWED AND MARSHAL. SUBMIT A COPY OF THEIR PERMIT TO THE position and where the dwelling is wholly contained within the pool IN REPAIR AND REPLACE ANY DEFECTIVE " BUILDING DEPARTMENT-CONTACT PUBLIC SAFETY AT WITHIN 4-0 OF THE SHALLOW END AND 8-0 APPROVED BY THE ENGINEERING DEPARTMENT. 1 of i barrier or enclosure, alarms shall be provided at every door with MATERIAL FOR A PERIOD OF ONE YEAR FROM631-360-7553 FOR INFORMATION PIPING S direct access to the pool; or other approved means of protection, DATE OF COMPLETION AND ACCEPTANCE BY OF THE DEEP END. such as self closing with self latching devices, so long as the OWNER. degree of protection is not less than the protection afforded by items described above. NO SCALE