HomeMy WebLinkAbout48962-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE °` 4Prr SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48962 Date: 2/27/2023 Permission is hereby granted to: Sieger, Jo 41780 Route 25 Peconic, NY 11958 To: legalize "as built" AC in accessory garage as applied for. At premises located at: 41780 Route 25 SCTM # 473889 Sec/Block/Lot# 86.-1-7 Pursuant to application dated 2/24/2023 and approved by the Building Inspector. To expire on 8/28/2024. Fees: CO-ACCESSORY BUILDING $50.00 AS BUILT-ACCESSORY $200.00 Total: $250.00 Building Inspector x " F " TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 o f Telephone (631) 765-1802 Fax (631) 765-9502 lett :/Avvuw,southoldtownily. pow° Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO, Building Inspector: 9 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,anI�.�ud , ' Owner's Authorization form(Page 2)shall be completed. r �kkpG�9 G bC1p a ua�; ',..h Date: February 24, 2023 OWNER(S)OF PROPERTY: Name: Timothy R. Sieger SCTM # 1000- 86-01 -07 Project Address: 41 780 Route 25 Peconic, NY. 11958 Phone#: 516-384-0728 Email: Joysieger54@gmail.com Mailing Address: 41 780 Route 25 Peconic, NY 11958 CONTACT PERSON: Name: Timothy R. Sieger Mailing Address: 41 780 Route 25 Peconic NY. 11958 Phone#: 516-384-0728 Email: Joysieger54@gmail DESIGN PROFESSIONAL INFORMATION: Name: NONE Mailing Address: Phonr'#- Email: CONTRACTOR INFORMATION: Name: OWNER Mailing Address: Phone#: Email,. DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project ❑Other Air Cononer Location and installation $ $2000 Will the lot be re-graded? ❑Yes �]NO Will excess fill be removed from premises? ❑Yes C�No 1 PROPERTY INFORMATION Existing use of property:Residense Intended use of property: Residense Zone or use district . ..... ...._ . in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes t<No IF YES, PROVIDE A COPY. Check ox AfterReading: The owner/contractor/deslgn professional is responsible for all drainage and storm water issues ax provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply With all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application SubmitteI'll- print na mo by `R. Sieger ❑Authorized Agent X91 Owner Signature of ApplicanDate" i STATE OF NEW YORK) COUNTY OF � Tim oth R. Sie er being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the OWNER ww (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith.. Sworn before me thi �3 day of r 20_ IUC Ota ry�p� GB9J ,STATE OF NEWYORK peg'St Pio.05FR62aa6M o ff4w In Suftk minty PROPERTY OWNER AUTHORIZATION 'my ww4ss'm o20: — (Where the applicant is not the owner) I residing at L___L.. .�..4L.....-;-,,, to apply on UU IICI Cuy auulo ize - ._...m...�......_ my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 1 � f BUILDING DEPARTMENT- Electricals ons TOWN OF SOUTHOLD n' UWOET, Q Town Hall Annex - 544375 Main Read - PO B&° VVISMU°HOS - o Southold, New York 11971-0959 . 7 Telephone (631) 765-1802 - FAX (631) 765-9502 ro.gerr@_southoldtownny.gov - seand southoldtownn . ov APPLICATION FOR. ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Alan Hubbard Electrical Contracting Inc Electrician's Name: Alan Hubbard License No.: 4285-ME Elec. email: Elec. Phone No:631 -697-1715 ©1 request an email copy of Certificate of Compliance Elec. Address.: Po Box 2241 Aquebogue, NY. 11931 JOB SITE INFORMATION (All Information Required) Name: Timothy R. Sieger Address: 41780 Route 25 Peconic NY. 11958 Cross Street: Peco ;c Avenue Phone No.: 516-384-0728 Bldg.Permit #: email:Joysieger54@gmail.com Tax Map District: 1000 Section: 86 Block: 01 Lot: 07 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Aie conditioner connection Square Foota e: 1 .4- s .ft Circle All That Apply: Is job ready for inspection?: YES NO []Rough In Final Do you need a Temp Certificate?: 11 YES [ NO Issued On Temp Information: (All information required) Service SizeE11 Ph 03 Ph Size:NA _A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead rr vi dergr ouiiiu L-UL aiS i 2 iii Frame i is Pole v v vi n uvi ie on vervi ,e. r. Additional Information: PAYMENT DUE WITH APPLICATION Generated by REScheck-Web Software C�(J Compliance Certificate Project Sieger Energy Code: 2018 IECC Location: Peconic, New York Construction Type: Single-family Project Type:� yp New Construction r l Conditioned Floor Area: 1,940 ft2 Glazing Area 0% iv N Climate Zone: 4 (5572 HDD) � � �� Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 41780 Route 25 Peconic, NY 11958 Compliance: 2.7%Better Than Code Maximum UA: 225 Your UA: 219 Maximum SHGC: 0.40 Your SHGC: 0.30 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. EnvelQpaA5sgmbls Prop.Gross Area Cavity C on t Assembly or Req. Pr.. Perimeter Ceiling: Cathedral Ceiling 875 27.0 0.0 0.038 0.026 33 23 Wall: Wood Frame, 16"D.C. 1,920 19.0 0.0 0.060 0.060 104 104 Door: Solid Door(under 50%glazing) 21 0.300 0.320 6 7 Door Copy: Solid Door(under 50%glazing) 21 0.300 0.320 6 7 Door 1:Solid Door(under 50%glazing) 64 0.280 0.320 18 20 Door 1 Copy:Solid Door(under 50%glazing) 64 0.280 0.320 18 20 Window:Wood Frame SHGC: 0.30 10 0.300 0.320 3 3 Floor:All-Wood Joist/Truss 875 27.0 0.0 0.036 0.047 31 41 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Nicholas Hemby-HERS Rater 02-15-23 Name-Title Signature Date Project Title: Sieger Report date: 02/15/23 Data filename: Pagel of 9 REScheck Software Version 0: REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will' be met and how that is documented, or that an exception is being Claimed, Where compliance is itemized in a separate table, a reference to that table is, provided, # Pre-Inspection/Plan Review Plans Verified I Field Verified J:011 section ie V Complies? Comments/Assumptions & Re ID Value Value EComplies 103.1, Construcii.—ndr. sand wing777— 103.2 �clocumentation demonstrate es DoNot [PR1]1 energy code compliance for the -[]Not Observable ubuilcling envelope.Thermal envelope represented on ONot Applicable 'construction documents. 103.1, Construction drawings and —T]Complies 103.2, Edocumentation demonstrate Does Not ,403.7 Tenergy code compliance for [PR3]1 slighting and mechanical systems. E-]Not Observable % ? Systems serving multiple 0Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Ocomplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr UDoes Not ti [PR2]2 on loads calculated per ACCA Cooling: Cooling: bE]Not Observable Manual J or other methods Btu/hrBtu/hr— �ONot Applicable approved by the code official. Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 2 of 9 ....Section # N Foundation Inspection Complie� Comments/Assumptions & Rei ID J� 303.2.1 A protective covering is installed m to ;❑Complies [F011]z protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below 1 grade. ❑Not Observable;; ❑Not Applicable 403.9d ice-meltingsystem y controls flComplies [FO12]2 nstaIIed. UDoes Not r '❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2Medium ll pact(Tier 2) 3 Low la pact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 3 of 9 Section Framin / Rough-in Inspection 9 9 P Plans Verified Field Verified Complies? Comments/Assumptions # & Fie µIp Value Value 402.1.1, Door U-factor, U- U- ;JGomplies See the Envelope Assemblies 402.3.4 table for values. ❑Does Not [FR1)i J ❑Not Observable ❑Not Applicable 402.1.1, 'Glazing U-factor(area-weighted U- U- ❑Corrlplies ;Sae the Envelope Assemblies 402.3.1, average). i❑Does Not table for values. 402.3.3, S i 402.5 l q ;❑Not Observable u [FR2]1 t I i❑Not Applicable 303.1.3 U-factors of fenestration products °❑Complies A [FR4]1 are determined in accordance ❑Does Not l y, :with the NFRC test procedure or . ',taken from the default table. ❑Not Observable 9 ❑Not Applicable p 402.4.1.1 'Air barrier and thermal barrier li� . �, �;❑Complies.. k [FR23]1 installed per manufacturer's r: ❑Does Not f instructions. ",[]Not Observable ' ❑ComApplicable 402.4.3 Fenestration that is not site built R20]1 'is listed and labeled as meeting ��� �, ,` , ' " P Q AAMA/WDMA/CSA 101/I.S.2/A440 q; r ,�� �" r r r ❑D^0s'Not [F, :or has infiltration rates per NFRC ' ;� ,�ri�� , �r� � [--]Not Observable 400 that do not exceed code �` ;' ��r 1r %��rr ' �� ❑Not Applicable E :limits. 402.4.5 IC-rated recessed lighting fixtures �� rr��r rq �y it ,❑Complies 6]� sealed at housing/interiorfinishr it '`��r�r ,� ii%rr % r"=❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. „ � ❑Not Observable ❑Not Applicable 3 1 Supply and return ducts in attics r� ❑Complies FR 12]i 'insulated >= R-8 where duct is , ,/% riror r ���f j✓��r iyr 1 ❑Does Not p >=3 inches in diameter and >_ rr'f�// ❑NOt Observable " R-6 where < 3 inches.Supply and �� r l„ iii return ducts in otherp ortions of '%� �r ' �rii i� t ❑Not Applicable � � 'the buildinginsulated >= R-6 for %� ��'� o %%/ �rrf r q/u r r rq /rr r diameter>= 3 inches and R-4.2 o4r r rr rq r / , 3inches diameter, 403.3.2 rDutsarhandlersand filter Jr aComplies [FR13]1 � H4 boxes are sealed with ,jtlnts/seams compliant with ❑Does Not , nternational Mechanical Code or Not Observable u "International Residential Code, as ��i�;��i,;,,�;�!�%� �' ,';�%;'�i�% ;��'�; r❑Not Applicable 'applicable. 40 g �t % 1;/ i% /'%%, ri ❑Ctanrplies 3.3.5 Building cavities are not used as � irr i� k�t� r � [FR15]3 ducts Or plenums. D't�es Not y% l/ %i' / a ❑NOt Observable r H, ;r,�:..�T❑Not Applicable 403.4 HVAC piping conveying fluids R- R- i0co�pNot lies [F l R17]z above 105-F or chilled fluids i below 55 -F are Insulated to>R l u 3, ;❑Not Observable k l ;❑Not Applicable o- 403.4.1 "Protection of insulation on HVAC ; 1 � . /��^ '� �/'�% 1l i�i%�r;❑ Clmpll@s � [FR24] rpiping. t /�r� „��% ��r ;r,���, El Does Not k 1.,, ❑NOt Observable e `, „ G /ir' t❑Not Applicable ,r r r 1 r ri 403.5.3 Hot water pipes are insulated to l R- I R- i❑C'omplies [FR18]2 zR-3. i ❑Does Not a ul. 'l E ➢ Y ❑Not Observable '[]Not Applicaple 1 Hlgh Impact(Tier 1) 2 (Medium Impact(Tier 2) 3 JlLow Impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 4 of 9 ectiorw Framing/Rough-In Inspection Plans1erlfletl Fie:dV Verified orrwiaiie orrwlnwew�lr /Assmwmtions Re wl ' value lue 4 4P3;5 Automatic or gravity dampers are , , TIam lies A R1 ) installed on all outdoor air Cjoes Not n intakes and exhausts. ; ]Not Observable ; Not Applicable Additional Comments/Assumptions: 1 J High impact(Tier 1) 2 'Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & RR D 303.1 All installed insulation is labeled t Complies [IN!1312 'or the installed R-values ❑[does Not provided. '❑Not Observable r _ ENot Applicable a a 402.1.1, RFloor insulation R-value. R- R- ❑Complies ;See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood IlDoes Not Itable for values. [IN1]1 ❑ Steel a❑ Steel ;❑Not Observable ❑Not Applicable n t b + C 303.2, ;Floor insulation installed per ;❑C'omplles 402.2.8 ;manufacturer's instructions and �, Tboes Not [IN2}1 in substantial contact with the m' underside of the subfloor,or floor y ❑Not Observable !framing cavity insulation is in +❑Not Applicable R contact with the top side of sheathing, or continuous ' , insulation is installed on the ° underside of floor framing and ;extends from the bottom to the itop of all perimeter floor framing .- members. " 402.1.1, Vall insulation R-value.If this is a: R- R- I❑Complles ;See the Envelope Assemblies 402.2.5, 'mass wall with at least 1/z of theo❑ Wood E] Wood ;❑Does Not a table for values. 402.2.6 ;wall insulation on the wall ;❑ Mass °❑ Mass ❑Not Observable [IN3)1 exterior,the exterior insulation I ; requirement applies(FR10). ;❑ Steel E] Steel 10Not Applicable l a � i n � 303.2 Wall insulation is installed per ,� ; j1�� ❑Complies [IN413 manufacturer's instructions. %R I]Does Not o ❑Not Observable /r,t✓///ii i,��/�i/.rri/ l%i�!, �%/, %i� n ❑'Not Applicable p Additional Comments/Assumptions: EE igh impact(Tier 1) 1,2 1 Medium Impact(Tier 2) 3 1 Low impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 6 of 9 N Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions Section & e N ' 402.1.1, Ceiling insulation R-value. R- R- "❑Complies �See the Envelope Assemblies 402.2.1, Wood j402 2 2 ❑ !E] Wood ❑Does Not table for values. 1 ❑ Steel u❑ Steel ❑ ��402.2.6 ; Not Observable [F11]1 ❑Not Applicable 303.1.1.1, 'Ceiling insulation installed per ❑Complies 9 303.2 manufacturer's instructions. ❑Does Not [F12]' ;Blown insulation marked every 300 ftp. rr ❑Not Observable ❑Not Applicable g 402.2.3 Vented attics with air permeable . Cmli'es [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that r extends over insulation. '❑Not Observable i ❑Not Applicable X402.2.4 Attic access hatch and door ; ^❑Complies u R- R- , [F13]1 insulation >R-value of the E a ;❑Does Not adjacent assembly. ❑Not Observable a ;❑Not Applicable 1402.4.1.2 ;Blower door test @ 50 Pa. <=5 0' ACH 50 = p ACH 50 = �ncomplies 6 [1`117]1 :ach in Climate Zones 1-2, and 8 ;❑Does Not <=3 ach in Climate Zones 3-8. e a ❑Not Observable i ❑Not Applicable { 403.3.3 Ducts are pressure tested to g cfm/100 cfm/100 :❑Complies r [F127]1 determine air leakage with ft2 ft2 �❑Does Not either: Rough in test.Total leakage measured with a U ;❑Not Observable g pressure differential of 0.1 inch w a i❑Not Applicable p Iw.g. across the system including x u i ;.the manufacturer's air handler ti IX t :enclosure if installed at time of x U I jtest. Postconstruction test:Total r ry n E' {leakage measured with a IX pressure differential of 0.1 inch !w.g. across the entire system IX U ;including the manufacturer's air I g a °handler enclosure. p 2 a 403.3.4 Duct tightness test result of<=4 cfm/100 ; cfm/100 a❑Complies [FI4]1 Duct ft2 across the system or 9 ft2 i ft2 i❑Does Not <=3 cfm/100 ft2 without air a : e "handler @ 25 Pa. For rough-in ; I ❑Not Observable 'tests, verification may need to ❑Not Applicable ' r 6 403.3.2.1 Air handler leakage der ,occur during Framing Inspection. g designated ❑Complies [F124] y �b manufacturer at<=2%of ❑ Does Not design air flow. , ❑Not O bs ervable ❑ of Applicable 403.1.1 Programmable thermostats Complies [F 19]2 installed for control of primary Does �pg Not I heating and cooling systems and initially set by manufacturer torj` Not Observable _.,. _... code specifications. / ,, r ?,,,,; ry %' >❑Not Applicable 403.1.2 Heat pump thermostat installed Complies [ ] pumps. FI10 2 on heat ���i� /, ma�✓�i� ' ❑Does Not 1 , NOt Observable s❑ N ❑Not Applicable 403.5.1 Circulating service hot water /i��� ����/�� /� / �❑Complies , [F]11]2 systems have automatic or jfi i;j; 1 1l J%%/„ f/ ';:❑ »�%%i ' °� Does Not accessible manual controls. a '� ti%��l///,���% ��J�,�%%���f []Not Observable 1 ",ONO[A i ppucable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3]low Impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 7 of 9 Section # Final Inspection Provisions Plans Verified Field Verified P Value Value Complies. Comments/Assumptions & Re .ID_ X403.6.1 All mechanical ventilation system ;❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and airflow limits perTable ❑Not Observable I R403.6.1. ❑Not Applicable 1403.2[F126]z�µth�ough onet water s supplying heat --pipe heating 1 lCompl'ies Does Not systems have outdoor setback control to lower boiler water `❑Not Observable i temperature based on outdoor '❑Not Applicable _. temperature. 1 Heated water circulation systems ❑Complies 403'.5.1 [F128]2 have a circulation pump.The '❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- -❑Not Applicable syphon circulation systems are not present. Controls for I circulating hot water system pumps start the pump with signal for hot water demand within the e occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. r, 403.5.1.2 Electric heat trace systems / ❑Complies [FI29]2 comply with IEEE 515.1 or UL ;% []Does Not z 515. Controls automatically adjust the ener ;❑Not Observable gy input to the %; ' a ' heat tracing to maintain the ��� '.`❑Not Applicable desired water temperature in the 4035.2 De teamnd s haveculation trols atterhat ,l r ' OC plies [ 0] manage operation of the pump �! ,//bio ,�/�r�/ / r Does Not and limit the temperature of the �o' /' �/r';i' '' ❑Not Observable I water entering the cold water /�' it r/ ', '�° r ❑Not Applicable I piping to <= 104°F. �-'❑Com I 4 ,, Drain water heat recovery [F131]4 B55.1. P table watee was CSA i �:'❑Does Not /rij n a pressure loss of drain water heat �! i�/„/ ” o ri'�// /�i/� ❑Not Observable , recovery units for ❑Not Applicable w < 3 psi individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for �individual units connected t0 three or more showers. 404.1 � 90% or more of permanent i' '%;° G' / '// ❑Complies 1 1 fixtures have efficacy i /�� / ✓ � high Y Does Notr �'❑Not ObseNablE Not 9 lighting Y I ;�jif �iii,�i ii/% / ❑Comp��islcable 404 1.1 Fuel as li htin systems have / / �i p [F123]3 no continuous pilot light. 'Does Not f=lNot Observahle ❑Not Applicable 401.3 Compliance certificate posted. // Complies [F17]z ; Not ❑Does o 'T/m,", o/­',"',l / /Hserva 9///ir / ❑Not Ab / pl6 ablee I r r' /rr///�/� /r%/I//%%iil ✓i/r r /s 1 !High Impact(Tier 1) F2_,Medium Impact(Tier 2) 3�Low Impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 8 of 9 Section pleas Verified Field Verified I:F:In:alinspection Provisions fele �Naloe Complies? Comments,/Assumptions /St lferlCi 303.3 Manufacturer manuals fore, r ;complies 13 mechanical and water heating r ,i ElDoes Not o systems have been provided. l � d �C)Not Observable u Not Applicable u Additional Comments/Assumptions: 1 lHigh Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Sieger Report date: 02/15/23 Data filename: Page 9 of 9 c2018 IECC Energy Effidency Certificate l�j( MIMMMEMEMOMMOMEM Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor 27.00 Ceiling / Roof 27.00 Ductwork (unconditioned spaces): Window 0.30 0.30 Door 0.28 Heating System: DH113065A9421A 95 Cooling i System: 4T1"i 3036E10OOAA 13 SEED Water Heater: 30 GAL ELECTRIC .9 Name:__T_ Date: 02-15-23 Comments