Loading...
HomeMy WebLinkAbout48496-Z �o���OfFOl,�coG Town of Southold 12/20/2022 y P.O.Box 1179 53095 Main Rd �A, Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43703 Date: 12/20/2022 THIS CERTIFIES that the building GENERATOR Location of Property: , 605 Bay Shore Rd, Greenport SCTM#: 473889 Sec/Block/Lot: 53.-3=8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/2/2020 pursuant to which Building Permit No. 48496 dated 11/16/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Osdoby, Steven&Jaci . of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45459 12/27/2021 PLUMBERS CERTIFICATION DATED J Au o ized i ature f surf TOWN OF SOUTHOLD BUILDING DEPARTMENT C, x TOWN CLERK'S OFFICE oy meg ' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48496 Date: 11/16/2022 Permission is hereby granted to: Osdoby, Steven 24 Donna Dr Plainview, NY 11803 To: Install an accessory generator as applied for per Trustee, DEC and ZBA approvals. Replaces BP #45459 At premises located at: 605 Bay Shore Rd, Greenport SCTM #473889 Sec/Block/Lot# 53.-3-8 Pursuant to application dated 10/2/2020 and approved by the Building Inspector. To expire on 5117/2024., Fees: PERMIT RENEWAL $117.50 Total: $117.50 BuilA Inspector o�SUFFe��, y TOWN OF SOUTHOLD co a 01 BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45459 Date: 11/18/2020 Permission is hereby granted to: Osdoby, Steven 24 Donna Dr Plainview, NY 11803 To: install an accessory generator as applied for per Trustee, DEC and ZBA approvals. At premises located at: 605 Bay Shore Rd., Greenport SCTM #473889 Sec/Block/Lot# 53.-3-8 Pursuant to application dated 11/4/2020 and approved by the Building Inspector. To expire on 5/20/2022. Fees: ACCESSORY $100.00 CO-ACCESSORY BUILDING $50.00 $85.00 Total: $235.00 Building Inspector pE SOUIyO _ # # T WN OF SOUTHOLD BUILDING PT. 765-1802 IN-SPECTIO N [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETYINSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [0Q ELECTRICAL (FINAL) [ ] CODE VIOLATION [ I] PRE C/O REMARKS: DATE /T712 INSPECTOR OF SOGTyolo - - — ----- # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Vol t DATE v l v INSPECTOR k��lw OF SO(/ryol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 c sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Steven Osdoby Address: 605 Bay Shore Rd city:Greenport st: NY zip: 11944 Building Permit#: 45459 Section: 53 Block: 3 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Promaster Electric License No: 59226ME SITE DETAILS Office Use Only Residential X Indoor X Basement Generator X Commerical Outdoor X 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 22kW Generac Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: v Date: December 27, 2021 S.Devlin-Cert Electrical Compliance Form FIELD INSPECTION REPORT DATE COMMENTS • � b C FOUNDATION(IST) -------------------------------------- FOUNDATION(2ND) V4 z 0 �e d ROUGH FRAMING& PLUMBING �1 i INSULATION PER N.Y. `3 STATE ENERGY CODE (� FINAL t . DITIONAL COMMENTS a J �~ �O 2Z - q%d. u..7• Srentwe0 3 of a a - 's S � r N 5. x ' H r Town Hall Annex Glenn Goldsmith,President ® °� ���� 54375 Route 25 A.Nicholas Krupski,Vice President ® P.O.Box 1179 Eric Sepenoski Southold,New York 11971 Liz Gillooly Telephone(631) 765-1892 Elizabeth Peeples ®� Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE 1949 C Date: August 17,2022 THIS CERTIFIES that the construction of a 16'x36' swimming pool and install pool equipment and a drywell for pool backwash,• install an at-grade 1 040sq ft paver stone patio along the south,east and westerly sides of swimming pool,• remove existing 12'x19' seaward side deck with ramp and stairs totaling 319sq ft and construct a new 14'x27' deck with stairs and landing(33sg ft)to grade a 3'x4' generator,and a 4'x8' outdoor shower-, with the condition to establish and perpetually maintain a 10' non turf buffer landward of the wetland boundary that no sand or fine materials be employed in the buffer that might float/wash or otherwise migrate onto the wetland from the buffer. The existing topography, a low profile berm noted sloping away from the wetland is to be maintained to prevent lawn fertilizer/mulch etc. washing over the berm into vegetated tidal wetlands;that no pesticides are to be used in the buffer,• that a low profile delimiter barrier be placed at the landward boundary of the non-turf-buffer and the lawn;that the derelict"t" stakes and derelict rusty galvanized wire fencing materials noted seaward of the chain-link fence be removed as tha represent a possible human or wildlife entanglement hazard;that any replacement of the chain-link fence is to be open constructed fence such as a split rail _fence to conform with Chapter 275 (Wetlands)standards and accepted environmental practice reducing habitat fragmentation; At 605 Bay Shore Road, Greenport; Suffolk County Tax Map#1000-53-3-8 Conforms to the application for a Trustees Permit heretofore filed in this office Dated MU 11,2018 pursuant to which Trustees Wetland Permit#9682 Dated August 19, 2020 was issued and Amended on April 14, 2021 and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the construction of a 16'x36' swimming pool and install pool equipment and a drywell for pool backwash; install an at-grade 1 040sa.ft. paver stuns patio along the south east and westerly sides of swimming pool;remove existing 12'x19' seaward side deck with ramp and stairs totaling 319 ft and construct a new 14'x27' deck with stairs and landing(33sq ft)to grade a 3'x4' generator, and a 4'x8' outdoor shower; with the condition to establish and perpetually maintain a 10' non turf buffer landward of the wetland boundary' that no sand or fine materials be employed in the buffer that might float/wash or otherwise migrate onto the wetland from the buffer. The existing topography, a low-profile berm noted slopingaway from the wetland, is to be maintained to prevent lawn fertilizer/mulch etc washing over the berm into vegetated tidal wetlands; that no pesticides are to be used in the buffer;that a low-profile delimiter barrier be placed at the landward boundary of the non-turf-buffer and the lawn; that the derelict"t" stakes and derelict rusty .galvanized wire fencing materials noted seaward of the chain-link fence be removed as they represent a possible human or wildlife entanglement hazard; that any replacement of the chain-link fence is to be open constructed fence, such as a split rail fence to conform with Chapter 275 (Wetlands)standards and accepted environmental practice reducing habitat fragmentation The certificate is issued to Steven&Jaci Osdoby owners of the aforesaid property. o Authorized Signature ®g�FFQ1i��D BUILDING DEPARTMENT-Electrical Inspector �y0 Gym TOWN OF SOUTHOLD ti Town Hall Annex- 54375 Main Road - PO Box 1179 tbc Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a7southoldtownny.gov– seand(&southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: —1+0 Ma5Lec, Electrician's Name: Fn U S License No.: Saaa(-, Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: f 11iIr Cross Street: Phone No.: BIdg.Permit#: email: Tax Map District: 1000 Section: j3 Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ar ���t �� Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YDS❑ NU ❑Rough In ❑ Final Do you need a Temp Certificate?: F Yt5❑ NO Issued On Temp Information: (All information required) Service Size 71 Ph F-�3 Ph Size: A #Meters Old Meter# ❑New service[:]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 7 H Frame Pole Work done on Service? 7 Y N Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 yy�►�� ��Ol� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c_southoldtownny.gov— seandtc'Dsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: Company Name: o Electrician's Name: Fnus License No.: Cl a P Elec. email: m � IcG � �) � OAN) Elec. Phone No: ❑1 request an email copy of Certificate of Comp iance Elec. Address.: JOB SITE INFORMATION (AuInformation Required) Name: p Address: Cross Street: Phone No.: ..,BIdg.Permit#: J� S� email: Tax Map District: 1000 Section: 53 Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please-Print Clearly): , Square Footage: Circle All That Apply: Is job ready for Inspection?: F Y 1=5 E]NO 0 Rough In 'F_1 Final Do you need a Temp Certificate?: Yl:=5❑ NO Issued On Terrrp--lnformatlon: (Allinformation required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# []New ServiceOFire Reconnect[]Flood ReconnectOServiee ReconnectQUnderground❑Overhead #.Underground Laterals F1 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION � 0 PERMIT# Address: Switches Outlets G FI's Surface, :_ . .. Sconces' H H's _.. . U C Lts . —06 Fans Fridge ..,•:_._._:.........: HW .. _.._. . . ... ..,._.. ... .. Exhaust Oven :WIo >:. .. 17. Smokes DW Mini. Carbon ;"IVlicro........... . Generator., :< Comljo: ...: ..:.:...:,.. ' 'Coolttop AC. AH- Hood ve ''s :Used. p ..: Special.:_..:. :. Comments: • I 1 Suffolk Environmental Consulting, Inca Newman Village a Suite E ® 2310 Main Street e PO Box 2003 o Bridgehampton NY 11932-2003 t 631.537.5160 Q f 631.537.5291 Bruce Anderson,M.S., President April 27, 2022 Michael Verity, Chief Southold Town Building Department P. 0. Box 1179 Southold, NY 11932 Re. Osdoby Situate: 605 Bayshore Road, Greenport SCTM # 1000-53-3-8 Building Permits:#45457, #45458, #45459 Dear Mr.Verity, Request is hereby made to extend the above referenced building permi0or an additional six months all set to expire on May 20, 2022. 1 understand that the Building Permit would then expire on November 18, 2022. Sincerely, Bruce A. Anderson a Cc. S. Osdoby �q as OF --r- NEA ��r +. ,• : . _IDES AS REQUIRED AND C ONDiTIVNS OF SOU T HOLD TOWN ZBA RM 0 SOLiTHOLD TOWN TRUSTEES FOR z. p,�aLlGH - !-RAMi.l'.,0, ,. t�lu!f, �a= o�� N.Y.S.DEC 3. INSULATIOi\!\ r�l.!C i 4Of d j%41j::T 4. FINAL — M,'- FCJR ::.C�. r� �t gj g� gE oNSTRECE O'CCUP ANC T OR ALL CONSTRUG�I�,1h,1 Sl-!F�.!..L Pr4F��� �;�'�. REQUIftEP�nEN-i S OF T}-tC CODES Ot=i.��3 ,. USE E i SUNLAWFUL YORK ST��CE. P4Ol- RESPONSi3L ►-�'R i ' TFUCT�ON OSSIGN OR GONSWITHOUT CERTIFICATE OF OCCUPANCY Cf�-�SpE�ON REQUIRED �R� ] : SCALE:: . . .�r. - R - 20 0' 40 P•1_P E .: 'FEET ).. " 1 f , ,h. 20 ::ft:. Wettand � < . .:: �.� dal".. Q :, ��. .. Ti ' Boundary, as, t� A �. dete.rmdn'ed, by . :SUffgik'• ' Envirbnmen ,ol: ' :'. . on Ccnstiltin.g�'•Inc J 016 'F i FE:' _ w CDNC: :MON.' j -Ni- ­FE..cFE. :F6f10E>'; t:37j..-TO CNR. a56'':E. 4,'s:kAETfIL. :2'Sa3''TC1?CNR:' ff Oa' ' fl •`''.. ,O ' :n:' ., Qt CA :0 ' )3 ;,'• 0..'. o•:MIN:, . BED 'POOL In, 'P.000' •' , EOl11F `r Min. v 0. x POSED: r. :RAM '?UP K OD EG. •:NO ri CK. E Lot, Coverage E=tQL E r-r, TYVCS�STORY 'F:F2AM _ Lot Area . 6�5 Wetland Area = ;.T53''0' S Ft'. d of{ #`. 3:9' �- 9; F: 'E'LV.' 1.. 7..44% Wetland ?2" O GI1R.:;F'LR.;':ELv: '1:1.9.' Upland Area _. l F:C:ci ror. �?' CELLA.( FCR. "ELV. 8.2 House Area:.= 1' 32fi: a ;a'••.: '. ', " Shed Area — 7&3 Sq. -Ft. Driveva�y/Walk A' ea = 1�179::7.'-Sq: .'Ft. Deck Area = 3191.T Sq:, 'Ft. Z+. ` :'+ :` i',: �.. :. Current QY-0199 _ 17,55%. :2T .. `. .Ae'p o I tlDriv�ewp Pitt'be P.ro osed,-Pool A ea _' 576: ' S: ft'. FE, ;•r„,;: `. r® ve :,and re aced.wlth P �li'.'` ed':elone.Apervlou�). P.ro bsed Qeck rea _ '3:92:8 0.3' E: , crush ' Proposed SVaI'k A ea s 104 -Sq;•-'Ft. Pool ,'Equip:' Area 1. ;-V sq .ft Genera.tor:•*r'e6: 14.'3 s,q'i,ft Shower Ar�:a: 32 O' sq:,:ft TANK LOT - Ej' ^.: . LO 4.4 v: N-/f N” F S:f:C U R A'N% A P:f .fC.E u} a SAN, . . CONC. - .WIN' :..:S7�•�b.5<�`� ;6,2.43. .T0: K�ER,,:.': . . OwA oHw- —: UTILITY J . ;. ., KAETEir- •'. :: ••.'�.:.-, 'ONW '=.P.OLE. U'nLiTY.. . PQUO EOGE'OF'PAVEMENT": .:: � � ' • . A Francis C. 1N `fsari: Licensed Land' urve or' ' • '' ' A COPY' OF THIS DQCUMEN.T 'NOT BEAR4NG. 'THE. SURVEY OF EXISTING -CONDITIONS AT LOTS 4 & 5 LAND.,SURVEYORS ;EMBQSSED. SEAL.AND- . ;�MAP OF PEC'ONIC .BAY.ESTATES — AMENDED MAP A F �,. SIGNATURE: 'SHALL NOT BE 'CONSIDERED'.,.A-TRUE ®' . E: LED -May 19, 1:93°3 ':AS MAP.No. 1;124 V. ANp' VALIQ„ORCGINAL COPY . �I ;'LPBER: 11"882 PAGE. 0914 SCTM' 1000=53-0'3-08 SI.TlJ''ftiT 70 AT ''..'. . son: Ld:n-d 'Sur-veyor 'P`C:: O coo . :Grove' G:R: N'PO.R'T p:. Ion -N.Y. 11.702 ;TQdWN 'OF 'SOUTHOLD SUFFOLK 'COUNTY NEW YORK y C'.OMMQNL,Y kNOWN .A'S: 63fi' 32$=3422 ph, 6 5:''B:aysh:ore `Rd. . ' 6'3;1: `677=3202 faX ;Greenpor,.t,. 'NY' J. f C'w b.t"s,o (- . 's' STEVEN:ASD-OBY AND JACI':OSDOBY /� QQ `. '•''UNAU7MORI EO:.ALTERATION?:OR•'AODITION•TO;THIS SURVEWlS;-A;VIOLA710N;:OF::SEC710Nu�C.•.� T"'•.507R®•, '7209=2 OF E.N,EW YORK STATE EDUCATION-LAW. COPIEs:'oF THIS suRveY'NOT BEARING:"'PI'OpOSed Pool, Equip., Generator, Shower and Leaching POOI shown �.. .. : _';•,�:'.:. i',RiE::UtND:SI'lRVEYOR$.:EAtBOS5Ep-'SEAL SHALL"NOT:BE;:CON§ID EDS TO-,'e�E•'i,Vi VAUD:^ .UES ." <. �:. .;:�gOP,Xe•,CUAR'AN, i,AN "CERTF.T,OwIIONs,I�IO,IgA1ED`;:FIERS'.`:S11'A..<RUN�ONIti�7D;:7}I in••B:L.I'JE� A� :PERsbN:sgOR;.X+HCA+.>:tHF��lsuRvEY::;15:^PeeEP1tED,.:wNa pnt►+se� ALk::T6:;aHE':RrtE.:"', A-AN `'.iOOMQ�IT.�Y:,<GOVERNMENT^ACENO '•ANDaENDIhIO,;;�N,S`TlfiJiTiONi,:CUkRATtfEES�ANDs•.:•>F SU % ' "'C6RTIf40AYlON5:ARE NOT+.TRIINSFERABLETO•:ADD1t10N'AI.,:1NST7UilONS:iOR':`. B, ENT::�:• �� ' OWNERS;.L',OCATIONS AND DIMENSIONS.SHOYM HEREON ARE,FOO A,F.ORMA•11q, r::��, POSES N.Y.S.:,.0 .:•'.,r+ 8 ;ONCY,.r\NO;ARE'NOT:,T.O,BE:USED,:TO-:,LOCATE ANY..:NEPVrEpNSTRt107,1QN'�.(;,. ,�?r:.e ED5°.: ;':,`S� .��� _ 20 'Surveyed 5, 2016 A .' .! 88 :AOOITONSj P60Ls, ETC.:J..'IMIS;SUR.VEYCR,WILL NOT BE HELD RESPONSIBL•E•;,t=,. R�r AL ' Sq thoLdf,Zo Revised �,:. 4, 2019...; - ry O Y ` GEIVERAC t GUARDIAN® SERIES 20/22/24 kW Residential Standby Generators Air-Cooled Gas.Engine INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power—Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz 6 Two-line multilingual digital LCD Evolution'"controller G007209-0;G007210-0(Aluminum-Bisque)-24 kW 60 Hz (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available - • Electronic governor t fsT> • Standard Wi-Fi®connectivity € • System status&maintenance interval LED indicators - s;.'Y;4ti' M • Sound attenuated enclosure • Flexible fuel line connectorz =" ° • Natural gas or LP gas operation • 5 Year limited warranty ;p .y, • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.' ` 'Must be located away from doors,windows,and fresh air intakes and in. accordance with focal codes. or C VI. US https:/lassets.swri.org/library/DirectoiyOlListedProducts/ E�/ O Qv' m 3 0 . Constiuctionlndustry/973_DoC 204_1 2 4-01-01_Rev9pdl I � Note:CETL or CUL certification only appplies to unbundled units and units ackaged with limited circuit switches.Units paclaged with the Smart Switch are JL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW- TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link Wi-Fi allows users to,monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile-Link,.users-are-taken-care-of-before-the-next-power-outage-- ---low--cost-tool-which-helps-save-money-over-the-wife-of-the-generator-Ancluded--with — model G007210-0. "' GENERAC , GENERAC• �IPROMISE � `0` `� ��� �� PWR � ..wr.�:..- GENE RAC® 20/22/24 kW Features and Benefits 04 04_ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. Remote mounting 'Mounts near an existing distribution panel for-simple,low-cost installation. PWRview`Transfer Switch(if applicable). • .PWRview energy monitor Energy usage at-a-glance. • .Ability to view real-time energyconsumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution'"'Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. - GENER-AC° 20/22/24 kW _R Features and=Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds,up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System •. 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection,to'the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models'poly) • Ability to vievi generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly,report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 W =f Specifications Generator Model G00703B-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 6007043-2 G007039-3 G007043-3 G007210-0 (20 kffi (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(NG) 18,000 Wafts* 19,500 Wafts* 18,000 Wafts* 19,500 Wafts* 21,000 Wafts* F� Na ZU & Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 R Main line circuit breaker 90 amp 100 amps 90 amp 100 amp 100 amp Number of rotor poles 2 Power factor 1.0 Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 67 67 67 67 67 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Displacement 999 cc Valve arrangement Overhead valve Governor system Electronic Starter 12 VDC Operating rpm ARF 3,600 mg -Z,' u -coosump Q, e NO U 4 • X!, Note:Fuel pipe must be sized for cull load.Required fuel pressure to generator fuel inlet at all load ranges-3.5 7 in water column(0.87-1.74 kPa)for NG,10-12 inywater column(2.49-2.99 kPa)for lP gas.For BTU content,multiply fts/hr x 2500(LP)or fta/hr x 1000(NG).Far Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. Ready to Run/Mainlenance messages µ Standard FE Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) "FrM&I-fiNY `2 Future Set Capable Exerciser/Exercise Set Error warning Standard Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). _4."P Smart Battery Charger Standard R Low Battery/Battery Problem Protection and Battery Condition indication Standard 'A' Pt 4 -,V., Under-Frequency/Overload/Stepper Overcurrent Protection Standard et Fuse .Fuse (6qi Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard High Engine Temperature Shutdown Standard r Fa IL me tA(q: .x-n5laridar Common external fault capability Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS551 4,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level;and also will decrease approximately 1%for each 10'F(6'C)above 60'F(16'C). - GENERAC 20/22/24 kW - Switch Options- Service Rated Automatic Transfer Switch Features Model G007039.1,G007039-3(20 kW) G007043-2,G007043-3,(22 kW _ • Intelligently manages up to four air conditioner loads with no additional hardware. of"'oleut ?: z _ r` r> g w 013:rrxt_Mz?:��.�.�:«', „�.�3. • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 64 with Smart Management Modules(SMMs). - max= y� -•° w �. • Electrically operated,mechanically-held contacts for fast,clean connections. Utilityvoltage monitor(fixed)' • Rated for all classes of load,1.00%equipment rated,both inductive and resistive. -Pick-up 80% -Dropout 65% f 6 • 2-pole,250 VAC contactors. RRurnwio:Ulily = se ' • Service equipment rated,dual coil design. Exercises bi-weeklyfor 5 minutes- Standard • Rated for both aluminum and copper conductors. I1? df=��u1e Enclosure type NEMA/UL 311 • Main contacts are silver plated or silver alloy to resist welding and sticking. Neu�it�br `(t_.;'Nyog(edf • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly w, 200 Amps 120/240,iH Open Transition Service Rated W .r. ,. Height Width .,, H1 H2 W11W2 Depth A. : in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges �..,:., Conductor Lug Neutral Lug T Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 4 f DEPTH I—wz PWRview Automatic Transfer Switch Features Model _ G007210-0&24kW) 9X 4C NAP • Integrated PWRview monitor provides real-time energy usage data through PWRview app. Current rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. NYWRI4 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor fixed)* with Smart Management Modules(SMMs). -Pick-up 80% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections, • Rated for all classes of load,100%equipment rated,both inductive and resistive: Exercises bi-weekly for 5 minutes* Standard • 2-pole,250 VAC contactors. NAL, • Enclosure type NEMA 3R Service equipment rated,dual coil design. RAT,cuiC;tiiea e'igd '; firysA :, ¢: Od g, r • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. w' ti•;: Dimensions <k �. 200 Amps 120/240,1 H Open Transition Service Rated Height Width ;:kF` :�• `�" � Hi g H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 GM 67.95 76.43 26.67 34.18 17.5 Wire Ranges -- DEPTH Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 �[. GENERAC® :-20/22/24 kW _= : _— Available Accessories ,.. ,�,,.� -,-�.,,. ., +,:.�-,�^ it 4�1F;h. re,z {,�.+r �" „= e7',.w.. , =-•. v.:-* ^3„,.y_, +r. :e. ;F :•-vs` �'�,�.�,.�- •,::���s��'r� �„�;�, ' ," � o _'rR4 ;Pr d °' D. BIDter. ,a' ",kt „�,. r< - a' rsz �a•,s?i*'. �' �zY _ :.,.- "' ;>;k` F fay. R. � Sa�' ','•. .� :as ; ;.>.`ens+.»uw �;•t.,� 7rn " s,.,:�.a.:.` ''`-',mew-�xr. r '—, `' ��as•',x� �. 4 ,>. 6005819=0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for 3 use with all air-cooled standby product(excluding PowerPact®). 6007101-0 JBattery Pad War mer`Pad warmer rests under then Battery.Recommended for use if temperature regularly falls below 0 IF(-18°C).(Not nec- ° essary for use with AGM-style batteries). 600702T' 10il Warmer Oil warmer slips directly over the oil filter.Recommended for use if,temperature regularly falls below 0 IF(-18 IC).� 6007103-1 Breather Warmer X Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 jAuxiliary Transfer Switch .The auxiliary transfer switch contact kit allows the transfer switch to lockout a single large electrical load that may not be Contact Kit. needed.Not compatible with 50 amp pre-wired switches. G0,07027-0-Bisque [Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom ofthe new air-cooled generators.,This offers a sleek,contoured I(Standard on 22 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque.!Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to.protect from future corrosion. The touch-up'paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 13006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included): G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor.provides.constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in Verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. 13007000=0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce x(100 amp) the overall size and cost of the system. 6007169-0-40 LTE IMobileUP Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G00717070-Wi-FV 4Accessories a smart phone,tablet,or PC.Easily access information such as the;current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for#ast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power putage. IG007220-0:Bisque Base Plug KitBase plugs snap into the lifting holes on the base of air-cooled home standby generators.This offersasleek,contoured appearance,as well as offers protection from rodents and insects by.'* ring the lifting holes located in the base.,Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 697:6 mm 1216 mm - .. 125.1 In] [48.0 In] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 (3007039-3 696471074192 G007042-2 696471074208 727.2 mm [28.6 1n] G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 p p G007209-0 696471071511 G007210-0 696471078220 646 i12.2 mm 125.5 in] [48.5 in, LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 •generac.com ©2020 Generac Power systems,Inc.All fights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.A 07/15/2020