Loading...
HomeMy WebLinkAbout48232-Z Qg11fF01 Town of Southold o� off, 12/20/2022 o � L P.O.Box 1179 ot.. 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43706 Date: 12/20/2022 THIS CERTIFIES that the building HVAC Location of Property: 1175 Waterview Dr., Southold SCTM#: 473889 Sec/Block/Lot: 78.-7-15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/15/2022 pursuant to which Building Permit No. 48232 dated 8/29/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"HVAC unit as applied for. The certificate is issued to Azzariti,Paul&Carolyn • J of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48232 12/6/2022 PLUMBERS CERTIFICATION DATED Aut ed i nature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48232 Date: 8/29/2022 Permission is hereby granted to: Azzariti, Paul 101.Riviera Dr S Massapequa, NY 11758 To: legalize "as built' HVAC unit as applied for. At premises located at: 1175 Waterview Dr., Southold SCTM #473889 Sec/Block/Lot# 78.-7-15 Pursuant to application dated 7/15/2022 and approved by the Building Inspector. To expire on 2/28/2024. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $400.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $450.00 Building Inspector Town Hall Annex f i��} �s�� s, Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ° r- �� _ r A sean.deviin(D-town.southold.n .us Southold,NY 11971-0959 y BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Paul Azzariti Address: 1175 Waterview city:Southold St: Ny zip: 11971 Building Permit#: 4$232 Section: 7$ Block: 7 Lot: 15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HVAC Inspector Signature: Date: December 6, 2022 S.Devlin-Cert Electrical Compliance Form n OF SO(/T,��� TOWN OF SOUTHOLD BUILDING DEPT. �Y�OOrm� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ],Ms ULATION/CAULKING [ ] FRAMING /STRAPPING [�] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE y '?i INSPECTOR hO��OFSO//Ty 1177 6W # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: L :,:b l x can n c C� G'!0'1/'B r brak& DATE Z INSPECTOR 4 ' b i DEC 0 6 2022 BUILDING DEPT. TOWN OG SOILITY n _ _ _ _ ___ �'_ __ _ _ ---- _ -- - .. .� - _ 1�_ - ' �� - .5 #- -- Y �- --__-_ �- 5 - --- 7� __ t _s _ ���� i i, ��_ �C ,. `CC t, ��iG+l�i ii� �. ., _ r cwt .. + ,•:. 1 1 1 i t D FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) a 1. o�a� FOUNDATION (2ND) ROUGH FRAMING& =>_ PLUMBING t` INSULATION PER N.Y. STATE ENERGY CODE Fri -07 FINAL ADDITIONAL COMMENTS 0 c ' Z r. m (I'x \O x 11� 4`�\f ud b H I I I TOWN OF SOUTHOLD—BUILDING DEPARTMENT -Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �f Qom,o N Telephone(631) 765-1802 Fax(631) 765-9502h"s://www.southoldtowpa.gov arao, Date Received APPUCAMON FOR BUMO G PERW 7 For Office Use Only �- ` r. �If [ - F111 PERMIT NO. Building Inspector: l 4 i i Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)_OF PROPERTY: Name �t r '� sCTM#1000- 7S— 7 Project Address: ���� - '��i ��i� �,�•,s����1� -_ - a�l�',�c r 1�d Phone#: S-10 d _-° ( -, Email: bfi JJ / al Mailing Address: / PS aze r CONTACT PERSON: • Name: f� f✓�C7�� - Mailing Address: /l) _ 10Cf# dzewcl - - 4>otA /eC/ 97/ Phone-#:-4 ALJ �� �� r7�� DESIGN PROFESSIONAL INFORMATION: A, f e-1- Name: Mailing Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: p[ , w Other ✓-C o"7,"t f'�/f/'r $ Will the lot be re-graded? ❑Yes QNo _ Will excess fill be removed from premises? ❑Yes XNO 1 PROPERTY INFORMATION Existing use of property: - Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑YesI;No IF YES,PROVIDE A COPY. ❑ .,{i a','.{:' "`c t,ri�';�i.0,fe' ,(i-F ��f.1J.; .The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ]Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF �� �l ) La'14 r C �� /�, LI? .'_?"' being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Co?t Ctor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be.performed in the manner set forth in the application file therewith. Sworn before me this 11//.,,//,,_ 15 dayof OUl1 .2022 II��AllX S • T T NotaryPublic KYLEE S DEFRESE PRO PELM Y OVUM AUT HORRA N NOTARY PUBLIC-STATE OF NEW YOR No.01DE6420156 (Where the applicant is not the owner) Qualified-in Suffolk County //// My Commission Expires 08-02-2025 I, At'.L �ZZG� ,ti residing at ��/ lzlyey-za Alm 'Sa/'e- �0 S5aeayer AY lo hereby authorize �C,��YCeG r ///00 to apply on my behalf To S d-6uiIding-99partment for approval as described herein. /7 Z a z�- Owner's Si re Date ZaQ L 14 Z7 Print Owner's Name 2 vf Fq� BUILDING DEPARTMENT- Electrical Inspector J. TOWN OF SOUTHOLD Town H611'Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(csoutholdtownny.gov - sea nd(Dsoutholdtown nV.qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 7e, -7-Ir Company Name: f - Electrician's Name: (Aull'I License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: 7—,;2, Bldg.Permit#: email: R20111nnIllif. Ile Tax Map District: 1000 Section: _71�' Block: -7 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 6c, Square Footage: Circle All That Apply: Is job ready for inspection?: YES [] NO []Rough In Final Do you need a Temp Certificate?: F-1 YES N NO issued On Temp Information: (All information required) Service Size F11 PhF-]3 Ph Size: A # Meters Old Meter# FlNew ServiceF1 Fire Reconnect[]Flood Reconnect Elservice Reconnect ElUnderground ElOverhead # Underground Laterals E]1 2 0 H Frame E] Pole Work done on Service? M Y RN Additional Information: pa/00, yam rcv-etco", PAYMENT DUE WITH APPLICATION � BUILDING DEPARTMENT- Electrical Inspector I TOWN OF SOUTHOLD ® � Town Hall Annex - 54375 Main Road - PO Box 1179 .:+uING 17EP 7. � ® !��'y �,0,gvN OF c^�y ,; .,j �.1 Southold, New York 11971-0959 \ 1- ® Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr a(Dsoutholdtownny.gov sea ndr'aD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: -7e, —Ir Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: cpi,J ��Gf/i�r Address: , u,� O-L41 fld Cross Street: Phone No.: 5 7-,;Z Bldg.Permit#: I � email: R22Ec `' Tax Map District: 1000 Section: -7!S Block: '7 Lot: I,SA 9 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): A C/�t V 6c, 1 Square Footage: Circle All That Apply: Is job ready for inspection?: ® YES ❑ NO F-]Rough In ® Final Do you need a Temp Certificate?: ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 PhF-13 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[-]Flood Reconnect❑Service Reconnect❑Underground[]overhead # Underground Laterals 1 R2 H Frame D Pole Work done on Service? Y DN Additional Information- 17(e nformation: l7(ecjs( Cv TIA ci A/0001'e ��r 2 66-- `f 5 PAYMENT DUE WITH APPLICATION 1-,T�� �� PERMIT k1 Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven W/D Smokes DW Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comments AP R VED AS NOTED DATE: B.P.# FEE: NOTIFY BUILDING Di-;'".RTMENT AT 765-1802 8 Aid 'O 4 TDM FOR THE FOLLOWING INSPECTIUNS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH -' FRS?IbNG & PLUMBING 3. INSULATION 4. FINAL - CONSTFRI!C.TION MUST BE COMPLETE FGA G.O. ALL CONSTRUCTK."AN SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELEC R!ICAL YORK STATE. NOT RESPONSIBLE FCRI�NS,Pk:,:(, p0i�l R E QUpb a E EO DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND COND71ONS OF j..,7a-1. -L-R ., Sir +rain i PJNiiiG 0 0 A R D eni ir+ini n��,AIrr�i iSTEES I tlY I 44-9 OCCUPANCY OR USE UNLAWFUL VVTT,HOUT GE R-TiFICAT F OCCUPANCY .i�''''.1. `a :-•P. Ys::,. - i. - _ _ , -HAG-096615.-40 -1 Api12012IM 0 r IV ,Advanced Disfr► o .}.,-: r��, �p1� ::g� �`. , �'ww� t' y 4,.i ' ''Y., >;.;i, 4•_e1,tri, X:,, '"�' r..�G:. ;�%-r • j :, rI�:l_ lt, s#al.lat 14 %,��11'i�''nLL ''l.`'{°'n,�tyy:i"y�'°TS:n„~-. '. r?,'. - :_ilk;... ?,`@.`- - rtf�,K,° .tif' ;a; j,:+'• F'`:'r,,�'!y'�•i':1' NN�?FiYs4... :.f.. h. :Sk'i: •'ty'C' '.j'. 'P ,: a orator .: f'S'_ - - - "� 'rA��*;.”. �-% .`i`�:y*{,.• �#• .�°'��'?x2s('r• Laav:6an, 9• .;..,'•p�, li ��,-•.+Yb'> ax� ' and ���Y.. �T i'..r �' - f t ., ,F.a r f; ,♦l" ,''"t. r'-"'•','' ' i♦§,'',fix .-q .�•::x T-c;-�.�;x:.''.-Y,. f C ; HorizoritaGA- 'oll Multi-Position A-Coil Slab Coil orizontal A4 at[ -' tt• l,; A-Coil �' 6 p8ge.7' "Top Conn�'a. ons Side:Connewctron es 4, .,a.:. 7, ;Y Page 4 Pages-4- }: Page. .b. t; Page, Y ; PNA antimicrobial,oroiluet'p cdtdcti qn GENERA coils are designed use with conddt%ing;unitsyor heat-.pump.units.'.These:inUrt boll re n` Pada ADP evaporatory general guide and do not supersede IocaLcodes in any Way.Consult'vnth ocalauthocities.hs~il�q J Read this installation manual and;,#ll"Warning" statements.prior.4c installit0M,%lie`eVap®�ato�` ; Check coil for°shipping damage and.verify the contents of the bolt containifi the eVa orator coil. If you Isil find damage, 7 t match �r"' trolls--are immediate) contact the.last carrier. Verify the efficiency requirements at?��PP.mann facturer fot6,With r grope I 'Ask>iig�? ror Y ,:' i 9 , pump units such as.capacity, SEER, EER, and HSPF. Che _ , ,,.oU-. r -t'•=,t..•.='j K I� shipped with a 10 psi dry "z' ` : x air holding charge. Puncture rubberplug on suction line to release.cgia ' ,. #or i m^ o P The absence of pressure does not verify a leak. hecC the coil for leaks' P„re iristallin or e , t wholesaler. �` ,.'< ,-wtiti a can of a polymer Position the coil on the outlet of the furnace using sheet metal screws. Drain heat exchangers eand 1%11 on sectional led Y temperatures up to 450°F. Maintain a 3” clearance on oil or drum type exchangers:' Coil should be level,or pitched slightly toward ain conne due to potential'wat r brflow face v low-off.'tRe err to Specification.'.. not recommended for downflow, or counterflow app Guide for limitations. - -- - i * Note:Large tonnage A&H coils(greater than 5 Tons)are not AHRI certified and do not have Microban protection. ** ISO 9001 :2008 c uL us 1; JL ILJID CERTIFIED- —Registered Quality System Advanced ns are subject to Product improvement is a continuous process at on our part.Pleasebcont utor ct your tADP s. representatvecor distributor oto verify details. change without notice and without obligation P ©by Advanced Distributor Products. All rights reserved. 2175 West Park Place Blvd.,Stone Mountain,GA 30087 www.adpnow.com r REFRIGERANT METERING Coils are suited for R-22 and R-410A refrigerants and can be used with or without a TXV. Replacement TXV part numbers are listed below; see kit instructions for change out or installation. ADP recommends placing a wet rag around the suction line at the cabinet during brazing to prevent overheating and damaging the sensing bulb. For optimum performance,the bulb should be reattached outside of the cabinet to the main suction line no more than one foot from the suction line connection and positioned on the suction line at 9 or 3 O'clock and insulated. When changing a system from AC to heat pump or heat pump to AC, check the current TXV specifications to determine if a TXV replacement is required. If the evaporator coil contains a Non-Bleed TXV and is used with a condensing unit containing a reciprocating compressor, a hard start mechanism will be required on the outdoor unit. Large Tonnage A-Coils of 7.5 Ton (R-410A) cooling capacity include an adjustable TXV that can be used to fine tune superheat. Turn adjustment clockwise to increase superheat 4°F per turn and counterclockwise to decrease superheat 4°F per turn. To return to factory setting,turn adjustment stem counterclockwise until the spring is completely unloaded (reaches stop or starts to"ratchet").Then,turn it back 6"Total Turns". R-22 TXV Part#s R-41 OA TXV Part#s •18-36 MBTUH Bleed A/C 65540600 18-36 MBTUH Non-Bleed A/C 65026401 42-60 MBTUH Bleed A/C 65540700 42-60 MBTUH Non-Bleed A/C 65026400 18-36 MBTUH Non-Bleed A/C 99167501 18-36 MBTUH Non-Bleed A/C-HP 65616601 42-60 MBTUH Non-Bleed A/C 99167502 42-60 MBTUH Non-Bleed A/C-HP 65616602 18-36 MBT H Non-Bleed A/C-HP 65616201 42-60 MBTUH Non-Bleed A/C-HP 65616202 HMPORTANT When changing - expansion -, the TXV MUST • refrigerant •• • - ••e •- • • possible • • - • damage. All coilsbe matched properly as listed in the AHRI directory- Cased coils with piston florator assemblies are shipped with a cap and nut over the threaded fitting. Remove the cap and nut slowly, allowing charge to escape, and secure the liquid line stub (attached to cabinet) to the florator assembly with nut. Discard cap. For optimum performance,the piston should be sized to Liquid match the recommendation from the outdoor unit manufacturer. I Line If the outdoor unit manufacturer does not recommend a piston size refer to the piston-sizing chart on page 3. 4— Her,Nut When changing ADP florator pistons, refer to Figure 1 and use i the following procedure: i 1.. Loosen hex nut located on liquid line and separate from distributor assembly. 2. Remove the existing piston from inside the distributor -4— Teflon 0.Rng Sea assembly. 3. Insert the desired ADP piston into the distributor ! assembly. i 4. Inspect Teflon O-Ring and replace if damaged. Ensure ADP Teflon O-Ring is in place. Piston 5. Re-install florator nut to body and torque to 10 ft-lbs. 4— Distributor Assembly 1 Coil Cabinet Figure 1 i i i 2 Florator Piston Size Ton R-22 R-41 OA Piston Size Part# Piston Size Part# 1 41 100000035 41 100000035 1.5 53 100000036 49 100000049 2 59 100000037 53 100000036 2.5 67 100000039 59 100000037 3 73 100000041 67 100000039 3.5 80 100000044 73 100000041 4 84 1 100000045 76 100000042 5 93 100000047 93 100000047 CONDENSATE DRAIN Coils are equipped with multiple drain connections. Determine the drain connections to be used and note the difference between the primary(green)and secondary(red)openings. Drain plugs are provided for all openings, remove and discard the appropriate plugs with '/" drive ratchet and verify that remaining plugs are tight. (2.5 ft-lbs) Attach drain line to pan with %" male pipe thread PVC fittings. Hand tight is adequate-Do not over tighten&do not reduce drain line size! Route drain(s) line so they will not be exposed to freezing temperatures and do not interfere with accessibility to the coil, air handling system or filter.The drain should be pitched downward 1" per 10'with a 2"trap as close to the coil as possible. If line makes a second trap, or has an extended run before termination,a vent tee should be installed after the trap closest to the pan. See Figure 2. If the coil is located in or above a living space where damage may result from condensate overflow, a separate W drain must be provided from the secondary drain connection. Run this drain to a place in compliance with local installation codes where it will be noticed when unit is operational. Condensate flowing from the secondary drain indicates a plugged primary drain. Prime the trap with water.Test line for leaks.Test water flow with unit in operation. An auxiliary drain pan should also be installed under the unit as specified by most local building codes. VENT MUST EXTEND A MINIMUM VENT IN THIS LOCATION (BEFORE TRAP) OF 2.00" ABOVE THE DRAIN PAN IS ACCEPTABLE AS LONG AS PROPER DRAINAGE IS ACHIEVED DRAIN PA73/4- MPT 2.00" MIN. CONNECTOR Figure 2 2.00" MIN. VENT "T" This product may in fiberglass wool insulation. Glass wool fibers . .. duringte of lifornia to cause Disturbing insulation .re known to the. glass woo .- . respiratory, � . I fiberglassskin or eye irritation. For further information on risks associated with .. Data Sheet available from • IMPORTANT The Clean Air Act of 1990 bans the intentional venting of refrigerant(CFC's and HFC's). Approved methods of reclaiming must be followed. Fines and/or incarceration may be levied for non-compliance. 3 A-COI L A-Coils are designed for upflow/downflow applications. Vertical drain pans have drain connections on the right and left front side of the evaporator coil. Airflow face velocity above 350 ft/min is not recommended for down-flow applications due to potential water blow-off. Refer to Specification Guide for limitations. In down-flow applications, aluminum foil tape must be applied to seal the top edge of the insulation to the cabinet. This tape will prevent the possibility of the insulation delaminating and blocking airflow. MULTI-POSITION A-COIL Multi-position coils come factory installed with a vertical and horizontal drain pan,which can be configured for up-flow,down- flow, horizontal blow-through or horizontal pull-through installations. In the center opening of vertical drain pan,a metal Inlet Air Restrictor is factory installed and is required for horizontal applications. It may be removed for vertical applications.Airflow face velocity above 350 ft/min is not recommended for downflow or counterflow applications due to potential water blow-off. Refer to Specification Guide for limitations. For horizontal configurations, install splashguard (included)onto the coil outlet,and extend suction line insulation into the coil cabinet by 2"to prevent moisture from dripping onto the insulation(the rubber grommet may need to be removed).Splashguard installation is not required for vertical configurations. Bottom flange of guard should rest on pan and sides screwed to the duct flanges. See page 5, Figures 4&5 for splashguard instructions. In down-flow and pull-through configurations aluminum foil tape must be applied to seal the top edge of the insulation to the cabinet. This tape will prevent the possibility of the insulation delaminating and blocking airflow. In horizontal pull-through configurations, a minimum 12"transition is required in front of the coil as shown in the figure below. This is required to ensure proper airflow distribution and to reduce pressure drop. Coils that are 20"or less in height and are installed in a cabinet with a height of 25-'/"or greater do not require a transition; all other coil models require this transition. Coil should be level, or pitched slightly toward the drain connection. It is recommended to add silicone caulk between drain pans to prevent water carryover. Note: Multi-position Coils are also field convertible from left-to-right or right-to-left;see page 6 for instructions on field conversion for horizontal airflow. Pre system startup checklist for Multi-Position coils—Refer to Figure 3 • Is splash guard installed?(Figure 3 Configurations A and B) • Airflow adjusted to rated CFM? • Is 12"transition installed as shown below?(non-standard horizontal applications) • Factory installed Inlet Air Restrictor present in the center opening of the drain pan(horizontal applications)? • Factory installed internal water diverter in place?Refer to Multi-Position A-Coil Field Conversion on'page 6. • Unit slightly tilted toward drain connection used? • Drain line connected and trapped per these instructions? Figure 3 FURNACE A. Standard Horizontal Application Airflow Left hand shown pp Splashguard Right hand similar(not shown) LOWEST STATIC CONFIGURATION See Spec Guide for additional data FURNACE B. Pull-Through .2 Right hand shown Splash- Left hand similar(not shown) guardLei lu m` r 12"min FURNACE C. Blow-Through Left hand shown Right hand similar(not shown) 12"min FURNACE D. Pull-Through Left hand shown Right hand similar(not shown) Apply foil tape to top edge of insulation 12"min 4 MULTI-POSITION A-COIL SPLASHGUARD Seal spashguard seams with silicone or other sealant. Fasten splash guard to duct flanges Q Q with(4)sheet metal screws,(2)on Q Q Splashguard each side. Screws can be installed Q inside out,or outside in. 0000 Angle spashguard to ensure O OCQ proper water drainage back �� O Open end of splashguard into horizontal drain pan. 0 should rest on the _ OO horizontal drain pan. Splashguard should overlap the horizontal 4"min drain pan by at least 4". Figure 4 — Splashguard without front slope Holes used to mount splashguard to duct First set of mounting holes are f flanges. - ._::: -7 used when horizontal drain pan % is flush with housing. ii /P/. Second set of mounting holes are used when horizontal drain pan is ?" shorter than cabinet height. Caution:These holes are for j / ® manufacturing purposes only. DO NOT use for installation! l� Fasten splashguard to duct flanges with(4) sheet metal screws. Screws can be installed inside out(as shown),or outside in. Figure 5 — Splashguard with front slope 5 MULTI-POSITION A-COIL FIELD CONVERSION Field Conversion Instructions from Left-to-Right or Right--to-Left Airflow Note: Typical horizontal left-to-right conversion shown. Models beginning with*E41,*E43 and*A91 are not field convertible(*reflects different cabinet color options). FOR EACH STEP, REFER TO FIGURE 6 BELOW: 1. Remove front panels and top tie bar. Pull the coil assembly from the housing. 2. Remove top tie bar and pull the coil assembly from the housing. 3. Remove the horizontal drain pan, and re-install it to the opposite side of the coil. (Note: horizontal drain pan must have drain plugs tightly closed in the rear of the unit). 4. Remove the top plate. 5. Remove the water diverter, and re-install it to the opposite slab. (Note: If your water diverter is attached by screws, remove screws,and bend tab straight or cut tab off). 6. Replace the top plate,and apply sealant to seal any air gaps. 7.. Before re-inserting the coil assembly, cut the front flange on the housing and fold it back to allow access to the horizontal drain connections(Note:Copy the factory cut-out on the opposite side of the housing). 8. Slide the coil assembly back into the housing. (Note: If unit is equipped with a sheet metal housing adapter, it must be moved to the opposite side of the housing). 9. Re-install the top tie bar. 10. Re-install the piping panel to the housing. 11. Cut a hole in the access panel to allow access to the horizontal drain connections, and re-install the access panel to the housing. (Note:.Access panel may need to be notched to allow access to suction header). 12. Seal old condensate drain connection cutout holes in the front panel to prevent air leakage. 4 6 5 0p 0 0 00 OQ0 00 ® QO 0 00 pp 00 O 0 00 0p 00 O Oo0 0 0 00 o ® ®n a o ® ® o 3 Note:Access panel may need to be notched to allow access to suction header. 2 & 9 0 0 0 0 00 00 0 1 Op 00 - 00 0 10 0p 0 OO 7 00 11 8 0 pOO Oo O ® ® O 12 Figure 6 Diagram shows typical conversion from left hand to right hand 6 HORIZONTAL A-COIL & SLAB COIL Horizontal A and HH Slab Coils are designed for horizontal applications only. Proper performance for Horizontal A-Coils requires that the air flow out through the tip of coil (Figure 7). HH Coils are bidirectional and require a transitional duct to complete installation. Horizontal A-Coils 17.5" and taller include.furnace plate adaptors to facilitate proper fit with furnaces of different widths. For Horizontal A-Coils with suction lines on side of cabinet, the suction line section inside the cabinet should be insulated with Armaflex®insulation(Figure 8). Discharge End of Coil Airflow '� Airflow ONLY ' = ONLY Armaflex®insulation Figure 7 — Horizontal A-Coil airflow direction Figure 8 — Horizontal A-Coil w/side connections qualify for an i' Your evaporator coil may q y Extended Warranty if registered within 90 n. For product registration days of installatio and more information please visit: i www.adpwarrantyxom Promotion Code: 567447 7112M00890 Serial Number: RE32636C175B1622AP Model Number: M �..,, t.. ."";V in such states or provinces where registration requmerd s are prohibited,failure to complete registration by the onsumer does no c diminish his or her warranty rights. 7 4`',1F REFRIGERANT CHARGING INSTRUCTIONS utdobr'temperature should be 60°F or higher. .Set the system to cooling mode:and charge per the applicable.method listed; ;6elaw..Foc1Heat Pump units initially charged in cooling mode, final'adjustrrrent to charge; in heating.mode:`:is;Acceptable:if, essary `�Nhen charging Heat Pumps in the heating mode, please refer to ttie outdoor unit's charging'instructions .• 1; FIXED-dRIFICE 1. Runs stem for at least 10 minutes to allow ressure to'stabilize. 2. Add or recover refrigerant until the superheat matches the table below. t Outdoor Air Superheat °F Temp. (°F) Min Nom Max 60 28 .31 34 65 25 28 31 ' 70. 22 25. 28 75 20 2'2 25 - 80 16 20 22 85 13' 16 20 90 10 13 16. j 95 6 10 12 w' 100 6 8 10 . 105 4 6 = 8 . 110 4 5 6 •115 4, 5 6 EXPANSION VALVE. 1. Run system for at least 10 minutes-to allow pressure to stabilize. 2. Add or recover refrigerant until the subcooling-matches the table below. 3. If equipped, adjust the valve until the superheat matches the table below. Subcoolin °F Superheat °F Min I Nom I Max Min Nom-:J Max 10 12 1 14 6- 10 .12 a • i+ PAdvanEx"dDistributor Prod acts Solutions for Your needs ',t2175 West Park Place Boulevard Stone Mountain,GA 30087 . .www.adpnow.com 5 ME.0 40-BF3 TECHNICAL,DATA h E r. B *E1 F E _ O -T_ r; A L DBIENSIONS MODEL B13..- A B C. . D E F 3,. Inches 913/16.-. -11-1/4 7'1/2 31/2 41/4 81/4- mm 249 286 193 89 108 210 *E1: 6"(1-52 mm),8 7/8'(225 mm)-& 10".(254 mm)tubes are also available. SPECIFICATIONS FUEL: ; No. 2 Fuel.Oil --------------------------==------------=---------- --------------------------=--------- =-----=----=-------------=--------- _FIRINGRATE__ _____ ____ : 0.50.to 0.95 US GPH. - ------------- -.-------=---------------------------------------- ---- - ECTIVE.OUTPUT: : 70 - - ----------------------- _ _ ___-,000 to-133.000 BTU/h- ---=---=----=---=-=---------------------- -- VOLTAGE_(Sin le Phase)__ __-;-_ee_ __ ::120V GOHz(*4.0%:=_15 o)------------------------- --- - =-------------- - - ------------ _ABSORBEI)_EI ECTRICAL POVfTER: : 492- -------------- Watts :.. - - - T------------------------------------------------------- -M0TOR-(rated): _ -_-- -3250_mm:RunCurrent21AMP. ------------------ ---- ' -------=------ ----------------------------------------------- - --=-------_-=-=------- - --- - ------------------------------ CAPACITOR: `:. - ----------i 12.5_Mi0ofhfads_260V _----------------------------------- -- - ----------- - - .. --------------=--------------------------=------ PUMP PRESSURE:' ; 100 to200-PSI -------=----------------------------------------=--- --- ---------------- - ----=--=-----==-------------------------------- ----- - Pi IMRY_CONTROL_----:_._ _ : RIELLO 530 SE/C'. -== ---- IGI&ION TRANSFORMER- -------- Y 8 kV 16mA.----*with.intake.air temperature at 200C(680F)-- MOUNTING FLANGE-DE" 30PNSIONS /tom . . :.. MODEL A $ C D E. F Inch: 7/16 1.3 /32 .3 9/-lb 5 9/16 7 9/16 8 1%2 mm :: .1F 180`..- 90. . :' 141. 192 =216 =� Thermo Pride® OIL FIRED COUNTERFLOW/*HORIZONTAL FURNACP SPECIFICATIONS MODEL-NO. OD6F/RA072D48(V5)B OD6F/RA07722D48(V5)R OD6F/RA072D48(V5)C HEATING CAPACITY High Fre Med Fre Low Fre High Fre I Med Fre Low Fre High Fre Med Fire Low Fre HEAT INPUT RATE(BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTU FF 89,000 72,000 60,000 89,000 72,000 60,000 89,000 72,000 60,000 SEASONAL E°FICIENCY2 85.7% 85.7% 85.0% LARGEST REC A/C3 4 Tons(5 Tons) 4 Tons(5 Tons) 4 Tons(5 Tons) NOMINALTENPRISE 66° 1 66° 1 66° 66° 1 66° 1 66° 66° 1 66° 1 66° HEAT ECCHANGERAIREA CASING HEIGHT(IN.): 45" 45" 45" CASING WIDTH(IN.): 20" 20" 20" CASING DEPTH(IN.): 30" 30" 30" NOMINAL FLUE OUTLET DIA. 5" 5" 5" APPROX SHIPPING WEIGHT LBS 250 250 250 APPROVAL STA d)ARDS UL727 CAN/CSA 8140.4 UL727 CANCSA B140.4 UL727 CAN/CSA 8140-4 QTY AND SIZE OF PERMANENT FILTERS ,,,_(2)18-3/4"X 12-3/4" (2)18-3/4"X 12-3/4" (2)18-3/4"X 12-3/4- ELECTRICAL REQUIREMENTS VAC/HZ/PH 120/60/1 120/60/1 120/60/1 MAX FUSESIZE(AMPS)PSCIECM 15/15 15/15 15/15 TOTAL CURRENT(AMPS)PSC/EDM 8.7/12.3 8.7/12.3 8.7/12.3 HEIGHT FROM FLOOR TO CENTER OF 20L1/2"/20-1/2" 20-1r2"1 20-1/2" 20-1/2"/20-1/2" FLUE (F/IZ) SUPPLY AIR OUTLET SIZE 18"X20" 18"X 20" 18"X 20" (W-IN.X D-IN.) RETURN AIR INLET OPENING SIZE 18"X 19" 18"X 19" 18"X 19" (W-IN.X D-IN.) ACCESSORY ITEMS 2-LINE SYSTEM IOT FOR ME-LO NIA 380705 WA COMBUSTION AIR IQT AOFS8397 AOPS8416 AOPS8433 FIELD VENT TERMINATION 19T AOFS8393 AOPS8393 AOPS8393 SIDEWA-L VENT ACCESSORIES i9T AOFS8394 AOPS8395 AOPS8432 COMBUSTIBLE FLOOR BASE 136-BASE D6-BASE D6-BASE COTTAGE BASE D60OT BASE D6O DT BASE 136C OT--BASE COIL CABINET CEI 12S.CE312T CE112S,CE317T CE112S,CE312T BLOCKE DVENT KTT4 AOPS2686 AOPS2686 AOPS2686 OIL BURNER BECKEITAFG(380692) RIELO BF3(380693) CARLN EZ-1HIP(380835) SUPPLY PLENUM PK181X201 PK181X201 RK181X201 RETURN PLENUM PK181X191 PK181X191 PK181X191 COUNTERFLOW CABINET /COIL 2-3TON CE112S/H03936UA170 CE112S/H S33936UA170 CE112S/HEE33936LIA170 CABINET /COIL 2-3TON HIGH EFF CE312T/HE47936UA205 CE312T/HE47936UA205 CE312T/HE47936UA205 CABINET /COIL 3.5-5 TON CE312T/HE50960UA205 CE312T/HE50960UA205 CE312T/1-E50960UA205 HORIZONTAL CASE)COIL 2-3TON F£13936CH210 HE33936CF1210 HM3936CH210 CASED COIL 2-3TON HIGH EFF. FE47936C H210 F E47936CH 210 HE47936CH210 CASE)COIL 3.5-5 TON FE50960CF1210 HE30960C H210 FE 509600 F1210 *Horizontal installation for left or right supply. I OUTPUTBTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER 2 SEASONAL EFFICIENCY(ALSO CALLED AFUE-ANNUAL FUEL UTILIZATION EFFICIENCY)RATINGS ARE BASED ON TESTS FOLLOWING U.S.DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING(AT.5 STATIC PRESSURE),SELECTION OF THE HIGHEST MOTOR SPEED IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS,USE ONLY WHEN CHIMNEY VENTED. P8020004 ECN 5713-MA 220406 s Model Number Digit 1 2 3 5 61 7 8 9 10 11 12 LL %. C LL cc to O V V ` 3 U. R !D lQ ® o o m x — V v v 3 E rt LU o o m m V a) x V v Oil Fumace Model Nomenclature Example Model Numbers O D 6 F A 0 712 D 4 8 B O D 6 F A 0 7 2 D V 5 R O D 6 R A 0 7 12 D 4 8 B O D 6 R A 0 7 2 D V 5 R O=Oil O H=Highboy D=Dual Poise D 6=Heat Exchanger Size Identifier 6 F=Front F R=Rear R A=Single Stage A Heating Capacity MBTUH 000's with factory installed nozzle 0 7 2 D=Direct Drive I I DI I C19.Airflow: Example=48MBTUH=4 tons @ 400cfm/ton 4 8 Cig.Airflow Variable Speed ECM V5=5tons V 5 B=Beckett,R=Riello,C=Carlin B -SEE NEXT PAGE FOR MORE DATA- 2 OIL FIRED COUNTERFLOW/HORIZONTAL FURNACE SPECIFICATIONS cs ven an Z, O O -3250 Yn Li�e+s as HL072 RB L30 vJ,ut o�m j 3mo Lv�anZ���III���iii��j Will WIDTH OD6FA072D*** SEE NEXT PAGE FOR MORE DATA- 3 17971 aR —REiI1RF!AIR VMTH cs —am 3M sqn 4.M . t F__ ' L30LYMM19249AIRWWJ 3D00 Lvmtmm�' Vw VETH OD6RA072D*"* CLEARANCES: FRONT FLUE REAR FLUE MINIMUM CLEARANCES TO COMUSTIBLE MATERIALS: SIDES o" 0' FRONT (Clearance to Combustibles)67/24"(Service) (Clearance to Combustibles)6"/24"(Service) SERVICE ACCESS REAR o" o" FLUE r r TOP W 0" SUPPLY PLENUM 1" 1" SEE NEXT PAGE FOR MORE DATA- 4 5I� j8 13-13/16" 2"J COMBUSTIBLE FLOOR BASE MODEL: 06-BASE COTTAGE BASE MODEL: D6COT-BASE ?oma 17-13/16" 0 0 COIL CABINET MODEL- CE112S 29-9/16" 0 0 0 COa CABINET MODEL: CE312T -SEE NEXT PAGE FOR MORE DATA- 5 OIL FIRED COUNTERFLOW/HORIZONTAL FURNACE SPECIFICATIONS BLOWER DATA: OD6F/RA072D48 0136FlRA072DV5 BLOWER MODEL DIRECT DRIVE 12-9 T-DD-1 1 12-9 T-DD-1 1 MOTOR H.P. '/HP 1 HP MOTOR TYPE&NUMBER OF PSC-5 ECM(CONSTANT CFM) SPEEDS HIGH SPEED AIRFLOW(SCFM)@ 0.51N.W.G.EXTERNAL STATIC 1600 2000 PRESSURE: Diameter x Width 12 x 9 12 x 9 BURNER DATA: RIELLO"BF3"WITH CERA-FELT SLEEVE AIR TUBE LENGTH(IN.) 4'/2" BURNER HEAD TYPE: Fixed FUEL TYPE: #2 NOZZLE RATING(GPH): .70 .60 .50 SPRAY ANGLE(DEG.): 800 80° 800 SPRAY PATTERN: HOLLOW(A) HOLLOW(A) HOLLOW(A) OIL PUMP PRESSURE(PSIG): 140 PSI COMBUSTION CHAMBER TYPE: REFRACTORY(SOFT CHAMBER) BURNER DATA: BECKETT"AFG-S-PLATE 3912(3-18-)31517 CERAMIC AIR TUBE LENGTH QN.) 4'/z" BURNER HEAD TYPE: F-3 FUEL TYPE: #2 NOZZLE RATING(GPH): .75 .60 .50 SPRAY ANGLE(DEG.): 700 700 70° SPRAY PATTERN: SOLID(B) SOLID(B) HOLLOW(A) OIL PUMP PRESSURE(PSIG): 120 PSI COMBUSTION CHAMBER TYPE: REFRACTORY(SOFT CHAMBER) BURNER DATA: CARLIN"EZ-1 HP" AIR TUBE LENGTH(IN.) 4%" BURNER HEAD TYPE: WA FUEL TYPE: #2 NOZZLE RATING(GPH): .75 .60 .50 SPRAY ANGLE(DEG.): 600 600 600 SPRAY PATTERN: HOLLOW(A) HOLLOW(A) HOLLOW(A) OIL PUMP PRESSURE(PS1G): 120 PSI COMBUSTION CHAMBER TYPE: REFRACTORY(SOFT CHAMBER) -SEE NEXT PAGE FOR MORE DATA- 6 OIL FIRED COUNTERFLOW/HORIZONTAL FURNACE SPECIFICATIONS OD6F/RA072D48 ALTERATIONS REQ'D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE HTG Speed by Inut Recommended CLG COOLING UNIT Low fire Mid Fire High Fire Speed 24,000 Low ML MH Low/Med Low 30,000 Low ML [MH Med Low 36,000 Low ML MH Med/Med High 42,000 1 Low ML MH Med High/High 48,000 1 Low ML I MH High Speed Tap 1 Furnace Airflow CFM vs.External Static pressure in.WC. Static Pressure 0.1 0.2 0.3 0.4 0.5 0.6 0.7 LOW 797 792 770 735 692 643 613 ML 1019 1011 1002 982 953 935 913 Med 1230 1219 1203 1191 1150 1114 1090 MH 1370 1357 1335 1316 1280 1238 1203 High 1846 1789 1750 1705 1640 1 1588 1533 Motor Current Draw Ams vs.External Static pressure in.WC. LOW 3.53 3.4 3.27 3.12 3 2.88 2.7 ML 4.6 4.53 4.46 4.33 4.2 4.09 3.99 Med 5.6 5.47 5A2 5.35 4.83 4.61 4.53 MH 6.7 6.28 5.97 5.76 5.46 5.22 5.01 High 8.26 8.02 7.78 7.49 7.14 6.86 6.58 Speed Tap 1 High Fire Tem erature Rise vs.Extemal Static Pressure in.WC. Static Pressure 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Low 104 106 109 115 121 128 143 ML 83 82 83 85 87 92 102 Sf":J;Gi,+ '�`�3`-'�4Fp' #:;yl:',1n<. n-c%n ry:v.•.,.V�ri!'S.`-; 65�ty,,q:;v F.ist;°" :3•i:s;r.:>,;,4;-• ".;3� `;•n„ ;vt"l ir4•, i,�f;:y`.5 Med MH V ,61!. _ ;63 '4. High 44 46 47 48 49 Speed Tap 1 Mid Fire Tem erature Rise vs.External Static pressure fin.WC. Static Pressure 0.1 0:2 0:3 0.4 0.5 0:6 0.7 Low 83 85 87 92 97 102 115 �ri,r��;�' y�`T� 1:�,:,,_ ;=c' ,,{; ;;,�.;x�;,. :�r�x�!' r�z' ,r-, • r,=z,, �..^«+ taw ML �:,;•_�6B" .'.66` `' 67' 68^;;_T ^ ;'T >' �x p i.... z .c. �n;' i'F>,;f•,0.4:c� .as73i<i-7�.'s:: 02 s'- °JX;4 'i''`- - - . 31 +�,"'{" `'kq`a#.'x`,!i•;rl.;" q°'2aA..., ;9`(.' ,', V. "'�f':{1!'l:n p';ti f:"i 9f:'r'rv3:":•. ,:a+t iryk-p' 9.':-3 {.:.Fu 4. u4m.- r S i,67: -5:+ Med rt%a�'va55,,�au�=�',;�..1�«55'i.,•.,5a,,.:.,,,m�56�.t.sn.t, .,,;�:�.57.,.zs.,. `yi���.,5 ..-:� ,.r. 6"9`: .rx,.... ,:., . MH 47 47 48 49 High 35 36 38 38 40 41 43 Speed Tap 1 Low Fire Tem rature Rise vs.External Static pressure in.WC. Static Pressure 0.1 0.2 0.3 0.4 0.5 0.6 0.7 LOW a" 69? ;`''`` °70; ` 72=.: :.76''":":Y='<" °:80:;'^.: 84 94 R�,'i^`i'.v?" 'R'E-':'s?5e1' '7.1Y.. �s"r 'x;i-"�kyy?P" ,-�,_ ?`tY� r.A±:-.:'- �{°Yfi•-' .'�-. "`fii'le,+ --- r,,a.V... ".;Nf.._t..1, rt f ay r.` :t� ti s k i'`` M ',•.a�.,e, t j,'y, P� ,G+,1• st E ilyi. �s.,.,;;`o,} 5,"'1`, y"�: ,.<sv� 4. f L' ML �'Xn';r5fl.. ,v� k�t^.v;:��r:�,..'v�%t. .,r�s`�ts�55•.i..;4;;:.�s *�w�;<�56a�, '�� :,; za58:,�'�,.t .,�0�*+',. �..,,�`,',,67�;;�,c».. Med 45 46 46 47 49 50trx MH 38 39 40 40 42 43 45 High 1 29 30---F 31 32 33 34 35 Recommended operation range -SEE NEXT PAGE FOR MORE DATA- 7 OIL FIRED COUNTERFLOW/HORIZONTAL FURNACE SPECIFICATIONS OD6F/RA072DV5 Heating Speed Set-ups NRGMAX UT Control Low Fire Med Fire High Fire Control Static Pressure BTUH 60,000 72,000 90 000Am Eo acts ECM Fan Blower Control Heat SWI Switch Heating Aprox.Rise Aprox.Rise Aprox.Rise Switch Settings CFM F° F° F° 0.2 0.5 Settings � 3-OFF3-OFF 4p, 755 1.3/114 1.9/173 -0FF2-OFF 01 1-OFF -OFF d3-OFF3-OFF82661.4/121 2.1/191 2-OFF 2-OFF ye,, FF 1.5/136 2.2/2033-OFF W. rim = 898 -0N 1-OFF ry 3-OFF 0%0 �' aJrk FF witch 2-ON 983 yk ,, `;x ,,; 1.7/155 2.41227 -ON ettings 1-0N 1 ; ; 1 1-0N v0._cX�..,iY` ,��".�� �:-,.,aE 3-0N R;,_ N 1068 Y 7' nor`r +yrs¢` r 77ar'' '� 1.9/176 2.7/259 2-OFF '`� tylR;C.E" � 2-OFF 1-OFF E,:,?J?, p .�':� �Y k'�t�i ed.,;3 Lifik„Ab.f:;:;a�Y: 1-OFF ,•;,o;fk`vX” ar;1,s�;z€_"se�.r8.,r�' s�%.''�� 3-ON 3-ON 1-0N 1168 ~h FF'p;7 ff v 2.2/203 3.0/286 1-0NF . _> 3-ON 3-ON 2-0N 1282 ? ,,t?84" ,:., 2.6/245 3.5/333 -0N 1-OFF3-ON 3-ON 2-ON 1424 -_ 8. 3.11299 4.2/400 -0N Recommended Heating Speed Setting SWI ON OFF v M N� -SEE NEXT PAGE FOR MORE DATA- 8 OIL FIRED COUNTERFLOW/HORIZONTAL FURNACE SPECIFICATIONS OD6F1RAO72DV5 UT NRGMAX Static Pressure Control Control Air Flow Am NVatts ECM Fan Blower Control Cool SWI Switch Clg. Switch Settings Tona a Cool Continous 0.2 0.5 Settings OFF 2 799 500 1.3/115 2-01185 FF 1-OFF OFF 3-OFF 6-OFF 2-OFF 2.5 1017 508 1.8/168 2.5/234 FF 1-ON ON 2-ONF 3 1210 605 2.4/219 3.2/308 OF 1-OFF FF 3-OFF OONF F 3.5 1404 702 3.2/301 4.1/395 N 1-ON N Factory Switch 3-ON 6-ON Settings 2-OFF 4 1622 799 4.3/412 5.4/532 FF 1-OFF FF 3-ON N -ON 5 2010 993 7.2/720 8.6/861 N 1-OFF FF Cooling Speed Set-ups SW1 ON OFF cn M N� 9