Loading...
HomeMy WebLinkAbout47946-Z UEf(1�1� �OSio Town of Southold 12/20/2022 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43711 Date: 12/20/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 880 Old Orchard Ln.,East Marion SCTM#: 473889 Sec/Block/Lot: 31.-6-23 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/11/2022 pursuant to which Building Permit No. 47946 dated 6/10/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to McKee JA Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47946 10/14/2022 PLUMBERS CERTIFICATION DATED u o ze Signature TOWN OF SOUTHOLD o4r �,�G BUILDING DEPARTMENT TOWN CLERK'S OFFICE o _ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47946 Date: 6/10/2022 Permission is hereby granted to: McKee JA Trust PO BOX 7 East Marion, NY 11939 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 880 Old Orchard Lri., East Marion SCTM #473889 Sec/Block/Lot# 31.-6-23 Pursuant to application dated 6/11/2022 and approved by the Building Inspector. To expire on 12/10/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector eG �, *2 Town Hall Annex , J � Telephone(631)765-1802 54375 Main Road +� P.O.Box 1179 sean.devlin(D-town.southold.ny.us Southold,NY 11971-0959 ` ✓�"i 4 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: McKee JA Trust Address: 880 Old Orchard Ln city,East Marion st: NY zip: 11939 Building Permit#: 47946 section: 31 Block: 6 Lot: 23 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Hytech Solar License No: 54187ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 14.4kW Roof Mounted PV Solar Energy System w/ (36) 40OW Modules, AC Disconnect, Combiner Panel Notes: Solar Inspector Signature: Date: October 14, 2022 S.Devlin-Cert Electrical Compliance Form OF SOGTyO� ��(�•� ��v /� V r�i �� # # TOWN OF SOUTHOLD BUILDING DEPT. um, 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: - -jrrA/0A--, DATE I'Y 'L2 INSPECTOR ` SOUTyo<o # # TOWN OF. SOUTHOLD BUILDING DEPT. `ycourm N�`' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING ] FINAL?//ollW,'--' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: to AZ Oft k�z DATE W LL INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS Ss ►e FOUNDATION(1ST) �y y ---------------------------------- FOUNDATION(2ND) ,' l ROUGH FRAMING& PLUMBING INSULATION PER N.Y. STATE ENERGY CODE LS r�}Gr FINAL ADDITIONAL COMMENTS y� Z aa„F�1 d b H a - r.r, . TOWN OF SOUTHOLD-BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtowiiny.gov Date Received rD-) For Office Use Only MAY .1 12022 PERMIT NO. Building Inspector: BUILDING DEPTTOWN OF SOUTHOLD Applications and forms must be filled•out in their entirety.Incomplete applications will:not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Dater 2lQ 2Z OWNER(S)OF PROPERTY: Name: `QCIL 1 C ,MC k!f C TSCTM#1000- 031 .op - 0(P 0 0 -d Z3,00Q Project Address: 99D Old Orchard Cd -) C MCS' I o n N 1 1 g 3 q Phone#: 031.702- . 3301 Email: i'Y�Cc1�Sl fly(@Q fipinll .i'1�-i- MailingAddress: U0 , oid Orcho-rcl ed E MOLL I On , N ( 1.q3q CONTACT'PERSON: Name: T1 moth S f-D 1 Mailing Address: lP wQShl'rdron A112 sho rC 1 10 LO Phone#: U'31 - 5 q 5 . 55S6o x a La Email:Sdcruz& dnsoIar- co In DESIGN PROFESSIONALINFORMATION:,- Name: Tomes J S b-t Mailing Address: 2 Cv-C L-n I E. N rth bre- , w 1 F73 Phone#: (031- �S 8 9.� .g Email:S.1-17u, hLLW@ MLsS4i-L+ar'ch .corn CONTRACTOR INFORMATION: Name: i l fih ftoUStQn@ H tCCIrl S. ICt.lr l Mailing Address:(P naghI Mn AVf, S h KJN 1 0 0 (D Phone#: X31' Jr�s S� U� x1 I Email: Sdcw-z o, hvicchs bko- "' CO rn DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: other SCS OX 12QJ2 19 1 S $ 7 U 1030 Will the lot be re-graded? ❑Yes ;Vo Will excess fill be removed from premises? ❑Yes ❑No 1 • PROPERTY INFORMATION Existing use of property:Singu s( lX Intended use of property: s(Y 9 Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes)KINo IF YES, PROVIDE A COPY. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Towncode. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuantto the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code andregulations and to admit authorized"inspectors.on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law: Application Submitted By(print name): - lmDthy t1-DuStcy-) $Authorized Agent []Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Si If-FC)I YL ) Ti n�OthV H--ouSfi On being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the C-0n Y-CLc-1o1- (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ``�i��r�rm® ••r 2b day of 11 .20 as 11111 P • • . •• rAe Nota Public OFTATF • : NO k' O 639 C°u (Where the applicant is not the owner) BJ,:• } 20s •:. �,� s ®• •. 4®. +,fp����Es o�1,�\• a I, os =Ue ll 1 -r MCII-Ce residing at 'H�Q O Id n rCVC'n E. MCQr LO Irl do hereby authorize -O i-r-C h SCAQ=C 1�nr to apply on my behalf to the Town of Southold Building Department for approval as described herein. OwVes Signature Date Print Owner's Name 2 BUILD NG DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD W e a Road - PO Box 1179 o Town Hall Annex- 54375 Main stip of ou�l-imo Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@,southoldtownny.gov - sea nd(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: TIM is C lrCtr I C Name: T1m th License No.: email: ihh'Z1Z (e3aak , C 0 rn Phone No: t031-L4-L3 . 0904 ®I request an email copy of Certificate of Compliance Address.: ,17-lP JOQCVrC)n BSC. CeVgAe rf N I JOB SITE INFORMATION (All Information Required) Name: QC C 1'I►'L2 c V C e Address: g O r 2d C. MCXr I0r) NU I I 0139 Cross Street: r-ol Phone No.: . -10c) . 3 3 0 to Bldg.Permit#: email: deSl n,era •r,.e+ Tax Map District: 1000 Section: 03I-000 Block: Ole .0 0 Lot: OZ3.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) l'Stci I S 010-r ray SuS fin - 12FJ 0 F ILL Check All That Apply: Is job ready for inspection?: DYES [n NO ❑Rough In ❑Final Do you need a Temp Certificate?: MYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame[]Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.x1sx Buildins Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, jafQ[Ir l Ina N C&C residing at W9 D i d 0 rchcj-a I?J � (Print property owner's name) (Mailing Address) C . MOYi On do hereby authorize -Ti-rn v ii ous VD n (Agent) RUtCC1 l Sp Lam.( (�to apply on my behalf to the Southold Building Department. zf� W&/At NAZ er' Signature) ate) (Print Owner's Name) i Suffolk County Dept. of Labor, Licensing & Consumer Affairs MASTER ELECTRICAL LICENSE jz'�...::X, • Name TIMOTHY HOUSTON vvSin2SS 1111'arno This certifies that the HYTECH SOLAR INC bearer is duly licensed by the County of su`foik License Number: ME-54187 Rosalie Drago Issued: 10103/2014 Commissioner Expires: 10/01/2022 i A� 12/06/22021021® CERTIFICATE OF LIABILITY INSURANCE DATE I) THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLYAND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT, if the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NOME Danielle Polonczyk Brown&Brown Insurance of Delaware Valley PHONE (856)552-6330 (856)840-8484 INC,No Ext): RIC' IC No 2000 Midlantic Dr,Suite 440 15-MAIL : dpolonczyk@bbdvins.com ADDRESS INSURER(S)AFFORDING COVERAGE MAIC# Mt Laurel NJ 08054 INSURER A: Southwest Marine and General Insurance Company 12294 INSURED INSURER 13: New Jersey Manufacturers Insurance Company 12122 Hytech Solar Inc INSURER C: 6 Washington Avenue INSURER D: INSURER E: Bayshore NY 11706 INSURER F: COVERAGES CERTIFICATE NUMBER: 12.11.2021 MASTER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR POLICY EFF POLICY EXP TYPE OF INSURANCE I D WVD POLICY NUMBER MMIDD MM/DD LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTMT_ CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 A PK202100015171 12/11/2021 12/11/2022 PERSONAL&ADV INJURY $ 1,000,000' GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2.000,000 X POLICY ❑jE O- F LOC PRODUCTS-COMPIOPAGG $ 2,000,000' OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANYAUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTYDAMAGE $ AUTOS ONLY AUTOS ONLY Per accident X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $ 5,000,000 A EXCESS LLAB CLAIMS-MADE EX20210001722 12/11/2021 12/11/2022 AGGREGATE $ 5,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION X STATUTE ERH AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE Y/N E.L.EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBEREXCLUDE07 � NIA W42088-5-21 12/11/2021 12/11/2022 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Installation Floater Single Location 100,000 A PK202100015171 12/11/2021 12/11/2022 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 .s- @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:2A371119-1D73-4C05-8A6E-F3DCA1EC2706 YoRlt '�dSCI'({ftl'a° CERTIFICATE OF ATS Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured 631-595-5500 Hytech Solar Inc 6 Washington Avenue. 1c.NYS_Unemployment Insurance Employer Registration Number of Bayshore,NY 11706, Insured ' Work Location of Insured(Only.required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number, 81-2376682 2.Name and Address`of'Entity Requesting Proof'of Coverage- 36:Name of Insurance Carrier (Entity Being-Listed as the Certificate Holder) _ New Jersey M6nufa6tuf6rs Insurance Company 3b.Policy Number of Entity:Listed in Box"1a';: Town of Southold W42088-5-21 PO Box 1179 3c.Policy effective period Southold,NY 11971 17/11/21 to 3d.The Proprietor,Partners or Executive Officers are © included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Danielle Polonczyk ((Print name of authorized representative or licensed agent of insurance carrier) ftcuSVned by: Approved by: 56Jqtr_b0Gr,F�ftature) *'"m pd4o. k (Date) Title: Broker Agent/Insurance Producer Telephone Number of authorized representative or licensed agent of insurance carrier: 856-552-6330 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wc6.ny.gov DocuSign Envelope ID:2A371119-1D73-4C05-8A6E+3DCA1EC270B Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such•state or municipal department, .board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter,notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(9-17)REVERSE NEW workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured HYTECH SOLAR INC 631-595-5500 6 WASHINGTON AVENUE BAY SHORE, NY 11706 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 812376682 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box 1 a" 53095 Route 25 DBL486077 PO Box 1179 3c.Policy effective period Southold, NY 11971 05/06/2020 to 05/05/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Y Signed 4/22/2021 B wwr 4f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE,Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB.120.1 (10.17) 1IJill P1°°u1°u11°°1°���(11°0-1�u�)°�IIII APP MED AS NOTED DATE: BP-9 LA 7 FEE: / BY: NOTIFY BUILDING DEPARTME AT 765-1802 8AM TO ,PAS FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - 1'WO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING S. INSULATION 4. FINAL - CONSTRIUCTION MUST BE COMPLETE FOS+ C.O. ALL CONSTRUCTION! SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CON[)ITIONS OF �nl r1 f,�l D Tt14hIN17RA c0{arud�l h 10IA.InI T°IJSTEES U iwu�V IVMY19 IIN IV,I,�',I.1"S u OCCUPANCY OR USE �'S UNLAWFUL ITH—00 CERTTM.�a SNF Tr o- � ���� I J A M E S J. S TOUT A R C H I T E C T & Assoc . 2 GREG LANE E AST NORTAP0RTN. Y. 831 - 8 58 9388 Letter of Certification May 5,2022 RE: McKee Residence 880 Old Orchard Road East Marion, NY 11939 To whom it may concern: I, James J.Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS(RCNYS), 2020 Energy conservation construction code of NYS(ECCCNYS), and the ASCE 7-16. The existing 2"x 6"@ 16"o.c. rafters will provide adequate support. James J.Stout Architect ED ARC .� 021!63 y4 T 36"Min, i 5 00 Ground Access ❑ ❑ aj W w ❑ LN O r o m f fJ F- C3 to_ z ❑ it ❑ —-- — L D w - , r 36"Min. m Ground ❑ W O4 .;�„_ Access jr-I , ^` � z .I. \ �' I 36"Min. p O \� �x !':.-j Ground I I<, '' z ��x Access IY } zO w U ❑ - \ O J Ll DO W W w [] i--- ------------ -----=� .I w U] w 0 UJ J o 40 ------------ 78"Min. --------;---- --------------f----------------- J! // ( ( '! W ent Area — J z LOCATION OF ELECTRIC METER AND AC DISCONNECT E%rSrING CHIMNEY ❑ z in w IL rnT DRIVEWAY N ❑ Min. 36"Min. w D 36" f" _ I Roof Ground ❑ I QN 18"Min. 36"Min. 3G'Min. Access Access N E LL Vent Area Ground Roof N U] Ul Access Access N v 11� W N ❑ N n > Q ❑ ❑ z w ❑ Z z a a r03-3 FRONT OF HOUSE `7 DRIVEWAY JACKIE MCKEE 880 OLD ORCHARD RD F Q:o EAST MARION,NY, 11939 In n IY p' PANELS 36 -3 d .cn o z x 'sy: N L7 F W IX . �. It 0 OLD ORCHARD RD N Lil ELECTRICAL NOTES =►L�� 1 SOLAR PV EQUIPED WITH RAPID SHUTDOWN Mso MINIMUM K-AIC RATTING OF ALL BREAKERS TO BE 10K Enphase AC cable In Consumption CT's 3 VERIFY GROUNDING ELECTRODE BIFNONE INSTALL NEW VERSION_HISTORY free air under module "A" "B" "C" "D" 4 ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE DB V#, DATE': DESCRIPTION AC&DC GROUNDING CONDUCTORS 'PER NEC ARTICLE FG 1 5w=2 Original 5 690A3(A)THRU(F)CONNECTED AS PER 690.45(A),690A6,8 I SIZED PER 250.122 _ L2 ALL EXTERIOR MOUNTED COMBINERS,JUNCTION BOXES, i6 RATED THROUGHS,DISCONNECTS,ETC.SHALL BE MIN.NEA 3R LATITUDE S — ELECTRICAL CONTRACTOR TO PROVIDE EXPANSION JOINTS 41.125195 ... ... G I I 7 AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC --- IV I ( !.__—.-....: _— —� .L� _� __.__;;�.— (�_,.__�i L - - REQUIREMENTS LONGITUDE I TOTAL RATING OF ALL OVERCURRENT DEVICES,EXCLUDING -72,342731 I I ^ I ��^ 8 MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED 1 o F�N l7 ` 4 — AMPACITY OF THE BUSBAR —'-- 'o' ' 4EN - a UTILTY COMPANY: SOLAR MAWI`_ I I ---, ; 9 THIS PV SYSTEM UTILIZES MICROINVERTERS.THERE ARE NO „° °„ U BREAKER iJi I ( { DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER. PSEG LI BRANCH-1 COMM HUB I__' ACCOUNT NUMBER , .. I j PROVIDE LABEUPLACARD AT EXISTING UTILITY CONNECTION MAIN BREAKER WITH"WARNING-CUSTOMER OWNED ELECTRICAL / t I I 10 GENERATION EQUIPMENT CONNECTED"WITH APPROPRIATE BRANCH-2 1 IHAZARD AND OUTPUT RATINGS OF PV SYSTEM N /\I _ M Fi tam--- o-- 0 I I X I LOCATION OF OVERCURRENTPROTEC71ONAS PER NEC ARTICLE 705.31: I �� I '-- C O f I Overourrent protection for electric power production source conductors,NET Q --i11 connectedto the supply side of the service disconnecting means in BRANCH-3 1 accordance with 705.12(A),shall be located within 3m(10 ft)of the point where `A/ O ^ j I the electric powerproduetion source conductors am connected to the service. HOMEOWNER: - #I -Solar Module -- —b�o— 0 `, '.�� I I r �— 1 I j I MISC NOTES - ------ #2-Micro Inverter ° _ I r ry , z 0 S Nm l m y i ; Jackie McKee , >— ` 504.4.7 ROOFTOP CONDUITS AND PIPING.TO THE MAXIMUM EXTENT Lig I / r I PRACTICABLE,CONDUITS,INCLUDING CABLE TRAYS,AND PIPING p i SHALL BE INSTALLED AT ROOFTOP LOCATIONS WHERE THEY DO ADDRESS: II I I I NOT OBSTRUCT ROOFTOP ACCESS LANDINGS,CLEAR PATH OF _ I REQUIRED CLEARANCES.IF IT IS IMPRACTICABLE TO AVOID THESE ® I I ^��° i—o�® i AREAS,CONDUITS AND PIPING SHALL BE DESIGNED AND 880 Old Orchard Rd, INSTALLED TO FACILITATE ACCESS AND MINIMIZE TRIPPING HAZARDS.STEPS OR RAMPS(OR PLATFORMS WITH STEPS,RAMPS East Marion, NY 11935 J OR LADDERS)SHALL BE PROVIDED THAT ARE CONSTRUCTED OF NONCOMBUSTIBLE MATERIAL,EQUIPPED WITH RAILINGS,AND ® I I—b I j GROUNDING ELECTRODE COLD WATER SERVICE(E) DESIGNED TO ALLOW ANY CONDUIT OR PIPING INSTALLATIONS G I (1)06 AWG __-GROUND ROD (1)#6 AWG x; COMPLIES WITH NEC THAT EXCEED 1 FOOT(305MM)IN HEIGHT ABOVE THE ROOF CU GEC -- e'DIA.V LONG CU GEC 250.52(A)1 SURFACE,OR MORE THE 24 INCHES(610MM)IN WIDTH,TO BE CONTRACTOR: pe EGC_ 250.66 — COMPLIES WITH NEC 250.66 + SHAREALL NOTE PLACED N AREAS OR INA MANNER THATILY TRAVERSED.STEPS,RAMPS,PLATFORMS AND LWOU DS Hyteeh Solar 250.52(A)5(B) OBSTRUCT ANY DOOR OR MEANS OF EGRESS,ALL CONDUITS AND PIPING INSTALLATIONS SHALL BE COLOR-CODED WITH ADDRESS: #4-Solar Load Center CONTINUOUS,DURABLE AND WEATHERPROOF REFLECTIVE OR 89L AC DISCONNECT LUMINESCENT MARKINGS AS FOLLOWS,AND FOR THE CONDUIT 6 Washington Ave,Bay Shore, #3-Roof To GENERATION PANEL #5-Existing Main #6-ExistingUtilityAND PIPING INSTALLED,SHALL BE CONTINUOUSLY LABELED IN AN NY 11706 Top g APPROVED MANNER. Junction Box Service Panel Meter PHONE: SEE SYSTEM OUTPUT RATINGS CHART BELOW PROPOSED EQUIPMENT LOCATION 631-595.5500 FOR BREAKER SIZING UTILITY METER EXTERIOR OF PROPERTY EMAIL: MAIN SERVICE PANEL INTERIOR OF PROPERTY iconnect@Hytechsolar.com SOLAR MODULES(N) (EXISTING)ROOF TOP MASTER SOLAR LOAD CENTER(N) EXTERIOR OF PROPERTY ELECTRICIAN: SOLAR SYSTEM OUTPUT RATINGS HOUSE MSP Timothy Houston EQUIPMENT TOTAL BRAND MODEL NOMINAL OUTPUT CURRENT 240V Voltage 1201240 ME LICENSE# SOLAR MODULES 36 Hanwha NOMINAL OPERATING VOLTAGE 1.21 Q.PEAK DUO BLK ML-G10+ Phase Single ME-54187 400 PV MAX DC OUTPUT 14A kW Phase ME PHONE,# MICRO INVERTERS 36 Enphase IQBPLUS-72-2-US PV MAX AC OUTPUT 10.8 kW Main 631-696-6500 INTERNET MAX AC OPERATING CURRENT 60A Breaker 200 A COMMUNICATIONS 1 Enphase Envoy-2P,15 A OCP p Efl ARO , HUB LEGEND - WIRE SCHEDULE C� SOLAR 89L AC TOTAL POWER OUTPUT=PTC RATING X# ' �� # EQUIPMENT # CONDUCTOR COLOR SIZE TY CONDUIT C? DISCONNECT 125A BUS SERVICE RATED ��l GENERATION 1 SQUARED LOAD CENTER,V MODULES X M.INV EFF I 1 SOLAR MODULE THWN-2 B R #12 2 g A IN 1"Schedule 80 PVC PANEL PTC RATING DC 376.55 W 2 MICRO INVERTER ECG THWN-2 G #8 1 A LOAD CENTER MAIN BREAKER W/TIE DOWN OCP 60A MAX INVERTER EFFICIENCY 97% 3 JUNCTION BOX THWN-2 B R #10 2 Q, B IN 1"Schedule 80 PVC 33 O TOTAL POWER OUTPUT DC(W) 13,149.13 4 SOLAR LOAD CENTER ECG THWN-2 G #6 5 MAIN SERVICE PANEL THWN-2 BR #12 2 ! O�{d�� ch Information Branch-1 Branch-2 Branch-3 6 UTILITY METER C ECG THWN-2 G #12 1 IN 1"Schedule so PVC SCALE 'PROJECT ,wtAL MODULES 12 12 12 THWN-2 BRW #6 3 NTS 2022-HT0087560004 D IN 1"Schedule 80 PVC BRANCH VOLTAGE 240V 240V 240V ECG THWN-2 G #8 1 PHOTO-VOLTAIC INVERTER AMPERAGE 1.21 A 1.21 A 1.21 A E ECG G #6 2 Solid Bare ELECTRICAL 3-LINE,DIAGRAN BRANCH AMPS X 1.25 18.116A 18.15 A 18.16A WHOLE HOME BACKUP OCP 521T,2P,20 A 521T,2P,20 A 521T,2P,20 A E-100.00 PAGE 1 OF 1. SOLAR INDIVIDUAL PERMIT PACKAGE SATELITE IMAGE CODE INFORMATION ° w o 00 14.40KWGRID-TIED PHOTOVOLTAIC SYSTEM ,� APPLICABLE CODES, LAWS AND REGULATIONS w { ° � 1- 0 000 2018 International Building Code(IBC)/2020 BCNYS Q N z ►�I � HOMEOWNERS NAME: O�A z+o 2018 International Residential Code(IRC)/2020 RCNYS w Q r J ��► } _j rn ., 2018 International Fire Code(IFC)/2020 FCNYS J r � j�,'t• w CI ' 2017 National Electric Code(NEC) o w JACKIE M C K E E 2018 International Energy Conservation Code(IECC) /2020 ECCCNYS m > Q ° m o GENERAL NOTES _ o Q i 0 m o 0 PROJECT LOCATION. 1.SOLAR PANELS WILL BE(36)(Q.PEAK DUO BLK ML-G10.A+) 40OW PV MODULES, ° F 7 AND(3�IQ8-PLUS-72-2-USMICRO INVERTERS Q "� Z D I 2.PROVIDE A.C.DISCONNECT: 240VAC,NEMA 3R. Q } Q 631-702-3306 3.THE AC DISCONNECT WILL BE LABELED AS"UTILITY DISCONNECT AND PHOTOVOLTAIC 0 Z � SYSTEM LOCK-OUT'LOCATED WITHIN VIEW OF THE ELECTRIC UTILITY METER. 880 OLD ORCHARD RD 4.IF IT IS NOT PRACTICAL TO LOCATE THE AC DISCONNECT WITHIN VIEW OF THE UTILITY Z W L) Z O METER,THEN A WEATHERPROOF PLAQUE SHOWING THE LOCATION OF THE SWITCH MUST _ (yJ U ❑ BE INSTALLED WITHIN VIEW OF THE ELECTRIC UTILITY METER. J Y ❑ EAST MARION NY 11939 , , 5.ALL WIRING TO MEET THE NATIONAL ELECTRICAL CODE. � D 6. THE RAFTERS AS INDICATED HAVE BEEN ANALYZED AND DEEMED SUFFICIENT TO 0— W Q SUPPORT THE ADDED LOAD OF THE SOLAR PANELS AND CONNECTORS. O N w 7.THE SOLAR PANELS MAY NOT BE INSTALLED ON AN EXISTING ROOF THAT HAS MORE [-] a) W w TOWN OF SOUTHOLD f THAN 1 LAYERS OF ASPHALT ROOF SHINGLES,UNLESS ADEQUATE MEANS OF SUPPORT ARE J 2 Q PROVIDED AS PER THESE DRAWINGS. < Q UTILITY: PSEG LONG ISLAND ,'. y' til"i B.THE MAXIMUM SPACING BETWEEN THE STANDOFFS SHALL BE 64"O.C. W to U $a � h W Ili Ul 9. THE SOLAR PANEL MOUNTING SYSTEM WILL BE BY SNAPNRACK SYSTEM. W Q 01 U Q Ua ATTACHMENT DETAIL LINE DIAGRAM SHEET INDEX 111 Ino E.I-,.�_,�� J Z ,... ..f COMP 411HQE ROOFlNG,TYP. L ,F MOT COW 1 Lr ROOF OECQNL,IYP. SITE MAP - LINE DIAGRAM - DETAIL11E111r umA Rqu v'a srnEw,Iw. woaoRgFiEnR It PAGE 2 O ROOF PLAN &CROSS SECTION O O Z STRING 1 (CONNECTED TO PV MODULES) 0 0 PAGE 3 Ln W ARRAY INFORMATION AND MOUNTING DETAIL > rrnn a STRING 2 ( CONNECTED TO PV MODULES ) O �j uJ U >xro w000 FFMRER PAGE 4N O Z w STRING 3(CONNECTED TO PV MODULES) ROOF PLAN LAYOUT NO FO Q O O PENETRATION DETAIL +wnsREn,ss. I (TSE p(�NEOFRE'E PAGE 5 N N [Y — ROOF PLAN LAYOUT w N O — F mIN m.�_­NTM NEW SOLAR AC 125A PAGE 6 N >_ E„UPSIgq,E•wo PROTKT .. m rnE RoaF Pvt'rRnnaw NEMA 3R SERVICE� ROOF PLAN LAYOUT-�E RATED LOAD CENTER Z Z — ' EXISTING EXISTING DISCONNECT Qm < m 200 AMP PAGE 7 UTILITY PANEL IN MAIN BREAKER =50A SOLAR PANEL LAYOUT O � 5,g sE IT METER -3 O D HOUSE P A —(3) 2 POLE 2 0 MP _ UR-40 RAIL BREAKER PAGE 8 _ RooF� f ro FOR USE WITH SNgPNRACX ULTSERIES RAIL$ SOLAR STICKERS Q STRUCttn�l METER IPAFTER) t�r•�teiE wrm eom siwlwo L � ` ���t111 /'//////// TOTAL SYSTEM SIZE: 14.40KW D ' ❑ Z MAY 1 12022 U3 BUILDING DEPT. I = o TOWN OF SOUTHOLD U1 Lo wrr � . N PL D STANDOFF KIT HF STANDARD STANDOFF N IJ.( z ❑ ❑ N 00 �1 0 W Q.PEAK DUO BLK ML-G10.A+ o 3 m f ❑ ❑ M O ❑ ❑ ❑ 40OWSOLAR MODULES 2' X 8' RIDGE BONDING F N ❑ C] Ln END-CLAMP 2"X 6" ROOF —L U Q Z [rl �� �� n RAFTER @ 16" J r ❑ ��� > < rn O.C. BONDING I- -- ) -- W N . . z o MID-CLAMP s dseat Foot i O/ I ����` o z SnapNRack UR-40 m i ULTRA RAIL l _ ---T i•.i---- m Ud ,� ❑ ATTR u, G S.S. Lag Screw r1 ° z 0 EXISTING ASPHALT ROOF SHINGLES ; ' i (�— �� U _ ROOF CROSS SECTION 1,4,5 & 6 (MAX 1 LAYER) ON 151 BUILDING PAPER ON �i Q� I IQ ;_ a i I � In 1/2' PLYWOOD SHEATHING O �/, f; ® i I (� o 3 SCALE 1/4'=1'-a' Z � 1 \\ �`````�� I I !-- -- ---- i--r i-2' X 8' RIDGE pBONDING 0' - Q END-CLAMP -----------i-----=-----1----- mow: ---------------------------------------------------- ~ -----------------------------------------------r- a­,cowe A•_ ; j r�/ i_ s aw<c ; W OO Cn BONDING W m w A71 C MID-CLAMP �;'t � ! Q SnapNRack UR-40 ULTRA RAIL W 0 Q U p _ �- DRIVEWAY J Q S.S. Lag Screw �p° (j D W _ - - J EXISTING ASPHALT ROOF SHINGLES ROOF CROSS SECTION Z & 3 (MAX 1 LAYER) ON 151 BUILDING PAPER ON �- FRONT SCALE 1/4'=1'-a' a 1/2' PLYWOOD SHEATHING OF O HOUSE � BONDING DRIVEWAY 0 Z BONDING END-CLAMP OLD)AWE MCI<" /W� ❑ RD MID-CLAMP EAST MARIONRVY�,1D939 In W H SnapNRack UR-40 _ ""E`S'6 [- j d ULTRA RAIL CO Q U) OLD ORCHARD RD ❑ u� U N o Z W ' S.S. Lag Screw ROOF PLAN/PANEL LOCATION N W Q EXISTING ASPHALT ROOF SHINGLES O = Q (MAX i LAYER) ON 151 BUILDING PAPER ON SCALE 1/16"=V-0" N a ��rtn� 1/2' PLYWOOD SHEATHING <` N - uJ W R❑OF CROSS SECTI❑N 7 N O Q SCALE 1/4'=1'-aN >' m W Z ❑ ❑ ❑ W 3 Q ❑ [Y Q] _ _ ❑ Q a PRIOR TO CUTTING OR ORDERING OF MATERIAL OR PLACEMENT OF THIS PROPERTY PRODUCES THE REQUIRED GROUND NOTE: ALL ROOF MOUNTING BRACKETS SHALL GROUND ACCESS POINTS ARE NON-OBSTRUCTED PER 2018 IRC AND — THE L-FOOT ATTACHMENT, FIELD VERIFICATION OF EXACT RAFTER ACCESS TO THE ROOF ACCESS PATHWAYS AS DRAWN. BE PROPERLY SECURED TO A ROOF RAFTER. 2020 NEW YORK STATE RESIDENTIAL BUILDING CODE. LOCATIONS ARE REQUIRE TO COMPENSATE FOR PREEXISTING RAFTER Q ro IRREGULARITY THAT MAY EXIST. THESE DRAWINGS COMPLY WITH THE 2018 IRC AND THE ACTUAL IN-FIELD ATTACHMENT TO THE ROOF WILL I- ••••� THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE (AF & PA' NOTE, WHENEVER POSSIBLE PLACE ? 'Q:�� �'.�� 2020 NEW YORK STATE RESIDENTIAL BUILDING MEET OR EXCEED NYS RESIDENTIAL CODE co WOOD FRAME CONST. MANUAL FOR ONE AND TWO FAMILY DWELLINGS. SMALLER SPAN BETWEEN ATTACHMENTS Ir =o; CODE. REQUIREMENTS POINTS TO AN OUTSIDE EDGE ❑R ZO F -U-) N;z= - OPENING IN A RUN. J I =y . C) 't' . O. W W• . C' L7 Z Q �'�//111/11111 N W a o [r] 00 rn w 0) w p � ° � � 0 000 F N ° � ARRAY INFORMATION J J N ,� z o N I; Zvi W = ATTACHMENT PENETRATION MAX MAX o ROOF PITCH ROOF AZIMUTH ROOFING TYPE RACKING TYPE TYPE FRAMING TYPE FRAMING SIZE O/C SPACING N PATTERN ATTACHMEN SPACING T OVERHANG Z ` In a ROOF 1 240 230° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STAGGERED 64" 19" D W ° m o ROOF 2 290 140° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STACKED64" 13 M Q ROOF 3 290 320° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STACKED 64" • ROOF 4 240 230° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STACKED 64 Z" 19" Z p = _ Q ROOF 5 240 140° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STACKED 64" 19" L p Z 3: D f10 ROOF 6 240 320° COMP SHINGLE RAILED SNR L- COT WOOD RAFTER 2"X 6" 16" STACKED 64" 19" Q Z LL Z W O ROOF 7 30 230° COMP SHINGLE RAILED SNR L-FOOT WOOD RAFTER 2"X 6" 16" STACKED 64" 19" D W U ❑ - � 0 < TABLE 2: PENETRATION GUIDE FOR INSTALL FIGURE 3: MOUNTING CLAMP W 0 OLO LO POSITIONING DETAILS Q 13 13 00 w w TWO OR MORE ROWS OF MODULES BOM i U] 19" 19" Q Q z 11 < LO 0 r UR-40 RAIL END CAP 42 PC. II J p U Q I I i i I i ARRAY SKIRT 115 Ft.cd id d I kJ H ARRAY SCREEN 320 Ft. i Od STACKED STAGGERED O Q-CELL 400W: O � I 0 I ! i Q.PEAK DUO BLK ML-G10.a+ 1DIn W 385-405 74" X 41.1" I PHOTOVOLTAIC SOLAR 36 PCSm Q — -1 74 �—. PANEL (see panel specs for U I more details) i 0Z U] N _jV1 N � LdO p Universal End Clamp 42 PC. i ON LO = ren — FULLY STAGGERED LN N U) W N O — F ONE ROW OF MODULES Universal Wire Clamp 22 PC. i O O m W O Z w 3 Q o m Wire Retention Clip 36 PC. I I ( I I I I I ( MLPE RAIL Attachment Kit 36 PC. 19" wk O Z e : `�� •do:� H •'� FULLY STAGGERED STACKED/STAGGERED SnapNrack Ground Lug11 PC. Q.PEAK DUO BLK ML-G10.d+ rn x -�'� �'3' Z 0 d ��• o Ln o Uj Li `� •RAILS SHALL BE POSITIONED IN THE NON-CROSS *CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN SnapNrack Mid Clamp 29 PC. HATCHED REGIONS Q L9? FOR EACH ARRAY. 7 NW LEGEND Pieuce — Cont ❑ ❑ 00 ® S-p—lk L-Eaai 90 Pc. rn `•/�J SnaONnck UR-40 W V' C===_ ) UL RA RAL 390 ft. Q{ELL 4— W L pj (rJ ❑ O Cl O I` U N Q. K QUO U(ML-GIO,d�' 38505 74-X41,1" 36 Pc. PM oLLTac$OUR —:LI p11A a�sto, -8' -4' --5'-4' -4' -4' —�'-4' -5'-4' -4 -4' --5'-4' H N Z 4 N Q ❑ [r1 - Q vl mR.R aetmN J J N ��; Z 0 0 I. K.-TAR- Ridge Line– �_—_ __--- — � � � ►�� w =18" Min. ----- — _ Vent Area W 36"MIN.ROOf ACCESS _ r!� 36"GROUND ACCESS AREA —ff------------ ff — _�---- -------�:------ -----$—.----:--- � --�--•---.-----: �--------.--- .—__---------�— � 0 m 1'-5' _ w a ---- a ( Z UT E%ISTING UTIIITV METE0. ff- - tl --- --. �----- --- $----�.--- --�----.------ �-------•- ---- --- T � � I'7 Q 10'-5" 1'-5' / —� a 138" SYSTEM - -- ------------ -------- ----------- '- Z 3 HEI HT 2'-2, — — m \ W w I Z ___________=IF_ / �___________ ___________ = w U O_ 1'-4IL ' 1 w_ ❑ I- - --/ m Q LL Q mw EXISTING VENT PIPE SnapNrack L-Foot O N — SnapNrack UR-40 Ultra Rail 0 z � W Ii w (Q.PEAK DUO BLK ML-G10.A+)40OW SOLAR O O MODULES W C] r 49'-11" � SYSTEM LENGTH LJL r Im 3'-5" NOTE: THIS ROOF WILL HAVE ( 19 ) (Q.PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #1 ❑ KW OUTPUT OF ( 7.600 KW) AND ( 19 ) IQ8-PLUS-72-2-US MICRO INVERTERS. — o z SCALE 3/16"=1'-0" 0 a O in w F V, > a 00 Q O U Ridge Line—�__— N 0 J Z w i------- ---------- 18" Min. N _ wclO / Vent Area N _ N U) 5 LT' Tf5 X — SYSTEM 1'-5' N ❑ Q HEI HTm Q 00 z W w Z CO 6'-2" SYSTEM LENGTH—j Q m 17'-8" — NOTE: THIS ROOF WILL HAVE ( 1 ) (Q.PEAK DUO BILK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #2 Q m KW OUTPUT OF ( 0.400 KW) AND ( 1 ) IQ8-PLUS-72-2-US MICRO INVERTERS. — SCALE 3/16"=1'-0" � � � �""i` O 7 J = may;• (7 Z N ���Illllllllll LEGEND Piece — Counk ® a,N L-Eppl 90 Pc. O Ln ULTRA RAIL 390 Ft. w W � Q-CELL 400 W: o t- 0 C� Q PEAT( 74'BLR NL-G10.z. Ridge Line -� ---_ o 365-405 T C x I c---_—_---_ —_ ] ❑ 0 ❑ 0 PHOTOVOLTAIC 50LaA PANEL(see panel ip 0., 36 Pc. \\ 18" Min. F N z more dcalls) \ _— __—_ Vent Area J - j �? ��� } -j m 18"MIN.VENT AREA 3i \ ` UI T SYSTEM 1r_rj i m o m ® PTA w 31,'HIN.RODE ACCESS HEI HT f - SnapNrack L Foot ❑ W n 1� \ +SYSTEM _ Ui iSnapNrack UR-40 Ultra Rail36'GROUND ACCESS AREA _E% UTI6'_2" 36" Min. (Q,PEAK DUO BLK ML-G10.A+)400W SOLAR Q Z LENGTH Access of MODULES N 0 0 —17'-8" Q NOTE: THIS ROOF WILL HAVE ( 1 ) (Q.PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #3 J o 1 KW OUTPUT OF ( 0.400 KW) AND ( 1 ) I08-PLUS-72-2-US MICRO INVERTERS. — o Z 3 SCALE 3/16"=1'-0" J -8• -e W w = z O Ridge Line Z w 0 \ �18" Min. Q 0 c \ _—_— Vent Area 7 , :F-7� -- IL Y 0 LO --__= LL Cj N Q 6' 2" \ co w HEITHM \\ SnapNrackL-Foot O -3 9 0 \ SnapNrack UR-40 Ultra Rail o z w W II w a J - 1'-7' \ \ I I J ❑ U _J (Q.PEAK DUO BLK ML-G10.A+)400W SOLAR U Q (f) r MODULES W J m YSTEM LENG H -16'-10" NOTE: THIS ROOF WILL HAVE ( 1 ) (Q.PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #4 KW OUTPUT OF ( 0,400 KW) AND ( 1 ) IQ8-PLUS-72-2-US MICRO INVERTERS. _ — O SCALE 3/16"=1'-0" O O L 'n W ❑ to 4' j a m Q U) __ _ Ridge Line O U� in._ N 0 J Z w Vent rea —_� 0 I Q Q 1'-7' N Cr N UJ w 6'-2" N0 F- SYSTEM Q HEI HT _ - 0 .. m C<)O o W 1'-7' SnapNrack L-Foot Q ❑ [L m J Q - ❑ 0 SnapNrack UR-40 Ultra Rail 13'-11" SYSTEM LENGTH (-.PEAK DUO BLK ML-G10 A+)40OW SOLAR Q m MODULES 24'-9" 111#,,11z, NOTE: THIS ROOF WILL HAVE ( 4 ) (Q.PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #5 , '•••.• KW OUTPUT OF ( 1.600 KW) AND ( 4 ) IQ8-PLUS-72-2-US MICRO INVERTERS. ❑ ado SCALE 3/16"=1'-0" = �• •r Z 0 �w�cn v.•Z� -] J IL SD o• I iii Oi ) QI D F- W X �i • �` Q 0 Z 7 N LEG EN D Piece Count BMJ ® Gn Nick L-Foot 90 PC. O �+ ----� ko Sn.pN—k UR-40 ULT0.S RAIL 390 Ft. _ W Q-CELL 400W: W (] [I] H ❑ ❑ p ❑ r N L5 'q _ " OTOVDLTVC SO Q. L L-G10.it Ln U51.1s 14•x 4`1136 Pc. PMLAR PANEL(see panty specs for } J (71 M 4,i aa:aiml J Q to ❑ = : 18" IN.VENT A0.FA r— rr z oCn u -4 -4'— '-4' -5'-4' -4' 47 �op Tq` a a ro 3E"MIN.ROOF ACCESS = W Ridge Li e�—� — � r 36"GROUND ACCESS AREA I--- —.--_ ---- --_------- .--------- --�----i ❑ m _ W Z 1'-7' a E%".STING UTILIiV METER U' O .4 — C 0 0 LO 6'-2" z 8'-4" SYSTEM 3'-1' N HEI HT a SnapNrack L-Foot J p Z 3 ==EF= o SnapNrack UR-40 Ultra Rail W Z a -- ----- J — Z W o O (O.PEAK DUO BLK ML-G10.A+)40OW SOLAR U D Q 36" In. MODULES nQ O < _ 29' 3" _ LL W RO D l- SYSTEM LENGTH - ❑ W Access mQ li (3 m W o a 32'-8" — O -3 N k N NOTE: THIS ROOF WILL HAVE ( 8 ) (Q.PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #6 w o Q � =il KW OUTPUT OF ( 3.200 KW) AND ( 8 ) IQ8-PLUS-72-2-US MICRO INVERTERS. _ — _j o n tD SCALE 3/16"=1'-0" . . U Q O W J � Ridge Une 1 0 ------- --- ----- O 1'-7' ❑ z ❑ r j a 27" 3'-1' SnapNrack L-Foot � < 6'-2" - -� S`ISTEM _ _ SnapNrack UR-40 Ultra Rail O U 0 LO HEIC HT =�___ ____= N O -) W 1'-7' _ (O.PEAK DUO BLK ML-G10.A+)40OW SOLAR 0 = Q ❑ MODULES N N IT 36" Min. — LSYSTEM LENGTH ROOF N Access N ❑ N Z NOTE: THIS ROOF WILL HAVE ( 2 ) (Q-PEAK DUO BLK ML-G10.A+) 400 WATT PV MODULE PANELS WITH SOLAR PANEL LAYOUT #7 F m Q r KW OUTPUT OF ( 0.800 KW) AND ( 2 ) IQ8-PLUS-72-2-US MICRO INVERTERS. 4 0 m SCALE 3/16"=1'-0" n p Q r� r ` ski Z •�'� ��% 0 (A ��`o �= 7 J a =oc;60 (D z LO co Q �''I//lilllll ` '3 NW 36"Min. Ground00 Access ❑ ❑ W Q1 W O ❑ O p O P N !7 r D Ln N J r ❑ Q z ❑ N j L o w �----I .----- --•— •--- r m i l L 'a = ' 36"Min. QI round O - ❑ Access — j 4 i I } rn — ` 11 Z0 i %"round Min. b AI ---_— --! ccess i I I u) i Q Q Z eximvc ven.nroe ! I i I i w I Z i j l Z w U o I I 0 i I Q ❑ Q �' --1 \��O i I jO i\-- J�� I I j U ❑ W -J r I LLm U Do w \Q NLj -3 U) 01 If) U Ir----------------------------- I Z Cr W co t w p J I i / I U O ^, ----- ----- ----- ----- ----- ----- ----- ----- — j / / Q to 18"Min. i11 h-------------------------------------------———————--i Vent Area �.—.—.—.—.—.—.—.—.------ �---.-----.—.—.—.—.-----------------r�--� I J Z LOCATION OF ELECTRIC METE T i I I I y— AND AC DISCONN=C IAI 'x; O Z Ln W N Q f l E p -� IJP I i j N 0 -1 Z W �- T 36"Min. 36"Min. DRIVEWAY N w Cl p Roof Ground ❑ = Q 18"Min, Access Access N 36"Min. 36"Min. N N Access Vent Area Ground Roof Access N U7 w N O I- N m > p O 0 Z W w Z FRONT 0 HOUSE Q �' DRIVEWAY JACKIE MCKEE 880 OLD ORCHARD RD F Q; EAST MARION, NY, 11939 LO F- o .� PANELS36 Z 0 c' 2z 7 J d •[Y.• o. LO LD W OLD ORCHARD RD Q L9 Z %�,,II";,;;;• P` N w • • • • Z ❑ O W A WARNING A WARNING W _� o NEC 690.31 (G) (3)(4) W ELECTRIC SHOCK HAZARD l'7 D o 0 Ln 0 • CONDUIT LABEL 1 PER 10 FT TURN OFF PHOTOVOLTAIC H N 1 LnZ Q ( ) TERMINALS ON THE LINE AND ' u W AC DISCONNECT PRIOR TO z cl m • LABELS SHALL APPEAR ON EVERY SECTION OF THE O WORKING INSIDE PANEL LOAD SIDES MAY BE ENERGIZED r N ? z a u, IN THE OPEN POSITION r Z WIRING SYSTEM THAT IS SEPERATED BY w. N O ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR m NEC 110.27 (C) NEC 690.13 (B) m ; FLOORS. ' � Q = m@� w o .PHOTOVOLTAIC AC D • L- G% o Q z SHUTDOWNRAPID PV N z p • cl 'MAX AC OPERATING CURRENT: 43.56 • • Z W o � • OPERATING • 24oV NEC 690.56 (C) (3) DISCONNECT , W 0 3 • SHALL BE LOCATED ON OR NO MORE NEC 690.13 (B) Z 10 Z NEC 690.54 THAN 3FT FROM THE SWITCH U W i Z 0 QLu W U ❑ J ° �AO AWARNING Q ft ELECTRIC SHOCK HAZARD POWER SOURCE W 0 H O ul W Q TERMINALS ON THE LINE AND OUTPUT CONNECTION. U LOAD SIDES MAY BE ENERGIZED DO NOT RELOCATE THIS Q Q row Q OIN THE OPEN POSITION% I OVERCURRENT DEVICE. J m U mi NEC 690.13 (B) • NEC 690.13 (B) NECl w Q III w . Cp � EC 705.12 (B)(2)(C) � _J Q U 0 W z 0Z O POINT A WARNING O — , _ � ® ■ ELECTRIC SHOCK HAZARDLINE SIDE TAP INSID;- p f TERMINALS ON THE LINE AND ro MAIN SERVICE PANEt.. LOAD SIDES MAY BE ENERGIZEDCAUTION ■Lu IN THE OPEN POSITION O ■ Z Z ZtWARN - - J POWER TO THIS BUILDING IS ALSO Ln w O Z A WARNING O o Q a. O 0 � SUPPLIED FROM THE FOLLOWING rrnn ❑ U O W Z ul TURN OFF PHOTOVOLTAIC z SOURCES WITH DISCONNECT(S) N ❑ Ld z 43.56 AC DISCONNECT PRIOR TO to O W 0 f- Q Q O kA OPERATING CURRENT: WORKING INSIDE PANEL I Q W 240 'Q Z LOCATED AS SHOWN: N ' - � N NEC 690.54 NEC 690.13 (B) & 110.27 (C) w ❑ } > Q Z N m " O 111111111 O ❑ z W UTILITY METER— w Z 44- SOLAR PV SYSTEM EQUIPPED ' • • WITH RAPID SHUTDOWN A WARNI NG 00 • - • • SOLAR LOAD a TURN RAPID ELECTRIC SHOCK HAZARD NEC 690.56 C 3 SHUTDOWN CENTER/DISCONNECT ( ) ( ) SWITCH TO THE TERMINALS ON THE LINE ANDIIIm L • SHALL BE LOCATED ON OR NO MORE "OFF"POSITION LOAD SIDES MAY BE ENERGIZED l� THAN 3FT FROM THE SWITCH IN THE OPEN POSITION MAIN SERVICE TO SHUTDOWN PV SYSTEM AND PANEL > ��,` ••'• ''''��i W REDUCE NEC 690.13 (B) ❑ •;�� SHOCK HAZAR IN ARRAY Lo PHOTOVOLTAIC - AWARNING DUAL POWER SOURCE Z 0 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 690.56 (C) (1)(A) ARRAY ON ROOF J i of o ;' E o _ SHALL BE LOCATED NOMORE THAN 3FT m 0 � �J'i•;� �.•� NEC 705.12 (B)(3-4) S 690.59 FROM THE SERVICE DISCONNECTING MEANS TO WHICH 880 OLD ORCHARD RD Z � �; ••••••• P�,,•�' THE PV SYSTEMS ARE CONNECTED. Q ' ,,,,% "3 N w ELECTRICAL NOTES 1 SOLAR PV EQUIPED WITH RAPID SHUTDOWN "VERSION 2 MINIMUM K-AIC RAITING OF ALL.BREAKERS TO BE 10KEnphase AC cable In Consumption CT's 3 VERIFY GROUNDING ELECTRODE&IF NONE INSTALL NEW STORY free air under module "A" "B" "C" "D" 4 ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE DB V# DATE DESCRIPTION AC&DC GROUNDING CONDUCTORS PER NEC ARTICLE FG 1 514x2= Original i I 5 690.43(A)THRU(F)CONNECTED AS PER 690.45(A),690.46,& LI SIZED PER 250.122 17 ALL EXTERIOR MOUNTED COMBINERS,JUNCTION BOXES, J' C 6 THROUGHS,DISCONNECTS,ETC.SHALL BE MIN.NEMA 3R i O _ RATED LATITUDE ELECTRICAL CONTRACTOR TO PROVIDE EXPANSION JOINTS 41.125195 •••••• �— I I 7 AN D ANC HORING OF ALL CON D UIT RUNS AS PER N EC — n --- ��-- REQUIREMENTS LONGITUDE -- I I I— TOTAL RATING OF ALL OVERCURRENT DEVICES,EXCLUDING -72.342731 8 MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED `� _ `� _ .._l��1 �` I I I • 6 Iv V i AMPACITY OF THE BUSBAR I I W1 SOLAR MAIfJI�I I i —�-^•-� �' THIS PV SYSTEM UTILIZES MICROLNVERTERS.THERE ARE NO LITILTY COMPANY: ... ... IJ BREAKER LI I 9 DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER. PSEG LI BRANCH-1 COMM HUB I I — ENPHASE PROVIDE LABEUPLACARD AT EXISTING UTILITY CONNECTION ACCOUNT NUMBER ✓� I---+/� �� /--- MAIN BREAKER 10 WITH"WARNING-CUSTOMER OWNED ELECTRICAL ENVOY / GENERATION EQUIPMENT CONNECTED"WITH APPROPRIATE m I BRANCH-2 I HAZARD AND OUTPUT RATINGS OF PV SYSTEM ' � � m F-1 ••• •.• �/� �� 1 LOCATION OF OVERCURRENT PROTECi10N A3 PER NEC ARTICLE 705.31 ' / \ ate— I CUSTOMER'S INTERNET Q '~ N Overcurrent protection for electric power production source conductors, _� 11 connected to the supply side of the service disconnecting means in BRANCH-3 I CONNECTION O accordance with 705.12(A),shall be located within 3m(10 ft)of the point where #I Solar Module the electric power production source conductors are connected to the service. HOMEOWNER: - � y� � Z rvi #2 Micro Inverter - I (� ___I /� _ I_ _ —�-�— Z I �_ I r— MISC NOTES O Jackie McKee X ��� ���- > 504.4.7 ROOFTOP CONDUITS AND PIPING.TO THE MAXIMUM EXTENT LU r I (n PRACTICABLE,CONDUITS,INCLUDING CABLE TRAYS,AND PIPING -- SHALL BE INSTALLED AT ROOFTOP LOCATIONS WHERE THEY DO ADDRESS: NOT OBSTRUCT ROOFTOP ACCESS LANDINGS,CLEAR PATH OF ® s REQUIRED CLEARANCES.IF IT IS IMPRACTICABLE TO AVOID THESE AREAS,CONDUITS AND PIPING SHALL BE DESIGNED AND 880 Old Orchard Rd, __T INSTALLED TO FACILITATE ACCESS AND MINIMIZE TRIPPING HAZARDS.STEPS OR RAMPS(OR PLATFORMS WITH STEPS,RAMPS East Marion, NY 11939 OR LADDERS)SHALL BE PROVIDED THAT ARE CONSTRUCTED OF ® --+J� J,►------ NONCOMBUSTIBLE MATERIAL,EQUIPPED WITH RAILINGS,AND GROUNDING ELECTRODE COLD WATER SERVICE(E) DESIGNED TO ALLOW ANY CONDUIT OR PIPING INSTALLATIONS G I I (1)t}6 AWG _„ GROUND ROD (1)#6 AWG +— COMPUES WITH NEC THAT EXCEED 1 FOOT(305MM)IN HEIGHT ABOVE THE ROOF CU GEC t'DIA.8'LONG CU GEC 250.52(A)1 SURFACE,OR MORE THE 24 INCHES(6-10MM)IN WIDTH,TO BE CONTRACTOR: .� 250.66 COMPLIES WITH NEC 250.66 READILY TRAVERSED.STEPS,RAMPS,PLATFORMS AND LADDERS 250.52(A)5(B) SHALL NOT BE PLACED IN AREAS OR IN A MANNER THAT WOULD Hytech Solar OBSTRUCT -- ANY DOOR OR MEANS OF EGRESS.ALL CONDUITS AND #4-Solar Load Center PIPING INSTALLATIONS SHALL BE COLOR-CODED WITH ADDRESS: CONTINUOUS, _— DURABLE AND WEATHERPROOF REFLECTIVE OR 89L AC DISCONNECT LUMINESCENT MARKINGS AS FOLLOWS,AND FOR THE CONDUIT 6 Washington Ave,Bay Shore, #3-Roof Top GENERATION PANEL #5-ExistingMain #b-Existing Utility AND PIPING INSTALLED,SHALL BE CONTINUOUSLY LABELED IN AN NY 11706 9 Y APPROVED MANNER. _ Junction Box Service Panel Meter PHONE: SEE SYSTEM OUTPUT -- RATINGS CHART BELOW PROPOSED EQUIPMENT LOCATION 631-595-5500 FOR BREAKER SIZING UTILITY METER EXTERIOR OF PROPERTY EMAIL: MAIN SERVICE PANEL INTERIOR OF PROPERTY icon nect@Hytechsolar.corn SOLAR MODULES(N) (EXISTING)ROOF TOP MASTER _ SOLAR LOAD CENTER(N) EXTERIOR OF PROPERTY ELECTRICIAN: _ SOLAR SYSTEM OUTPUT RATINGS HOUSE MSP Timothy Houston EQUIPMENT TOTAL BRAND MODEL NOMINAL OUTPUT CURRENT 240V Voltage 120/240 ME LICENSE# SOLAR MODULES 36 Hanwha Q,-PEAK DUO BOLK ML-G10+ NOMINAL OPERATING VOLTAGE 1.21 Single ME-54187 40 — PV MAX DC OUTPUT 14.4 kW Phase Phase ME PHONE# MICRO INVERTERS 36 Enphase IQ8PLUS-72-2-US PV MAX AC OUTPUT 10.8 kW 631-595-5500 Main INTERNET MAX AC OPERATING CURRENT GOA Breaker 200 A COMMUNICATIONS 1 Enphase Envoy-2P,15 A OCP HUB LEGEND WIRE SCHEDULE (�GAEO AAC ' 3. SOLAR 89L AC TOTAL POWER OUTPUT=PTC RATING X# # EQUIPMENT # CONDUCTOR COLOR SIZE QTY CONDUIT C7 DISCONNECT 1 SQUARE D 125A BUS SERVICE RATED MODULES X M.INV EFF THWN-Z B R #12 2 1 SOLAR MODULE Q "1P GENERATION LOAD CENTER,V A IN I"Schedule 80 PVC PANEL PTC RATING DC 376.55 W 2 MICRO INVERTER ECG THWN-2 G #8 1 1 LOAD CENTER MAIN BREAKER W/TIE DOWN OCP 60A MAX INVERTER EFFICIENCY 97% 3 JUNCTION BOX THWN-2 B R #10 2 J TOTAL POWER OUTPUT DC W 13,149.13 B IN 1"Schedule 80 PVC �' 21 r,33 OQ ( ) 4 SOLAR LOAD CENTER ECG THWN-2 G #6 1 `I 5 MAIN SERVICE PANEL THWN-2 B R #12 2 ( TF R NES C IN 1"Schedule 80 PVC Branch Information Branch-1 Branch-2 Branch-3 6 UTILITY METER ECG THWN-2 G #12 1 SCALE PROJECT TOTAL MODULES 12 12 12 THWN-2 BRW #6 3 NTS 2022-HT0087560004 D IN 1"Schedule 80 PVC BRANCH VOLTAGE 240V 240V 240V ECG THWN-2 G #8 1 PHOTO-VOLTAIC INVERTER AMPERAGE 1.21 A 1.21 A 1.21 A E ECG G #6 2 Solid Bare ELECTRICAL 3-LINE DIAGRAM BRANCH AMPS X 1.25 18-15A 18.15 A 18.15 A WHOLE HOME BACKUP OCP 521T,2P,20 A 521T,2P,20 A 521T,2P,20 A E-100.00 PAGE 1 OF 1 W W Ln -{ 7 Lr) F Wm W r, Snap rack- UR . • . ' . _ -'" straightforward rail solution for mounting solar modules on all roof Ultra Rail U7 z Solar Mounting Solutions features two rail profiles; UR-40 is a lightweight rail profile that is suitable for most geographic U ` Ultra Rail W - 4T profile provides..- .- . -. .: . .. . :. compatible. I o m with all r fl i existing mounts, •• • and accessories forof W1 a E O Q L Z " O " _ w t1 O The Entire System is a Snap to Install ][ d • New Ultra Rail Mounts include snap-in brackets U _0 ° Y o for attaching rail Q Mwc T Ln L�' • Compatible with all the SnapNrack Mid Clamps Ln �rlr' rn and End Clamps customers love a(, 0 C3.) c • Universal End Clamps and snap-in End Caps ?5 Q � p °. ,' m provide a clean look to the array edgeJ 2 o O Y o Z U1 U 6 w Ul J W f W W Q Unparalleled Wire Management _) W o c U1 • Open rail channel provides room for running J 0 U wires resulting in a long-lasting quality install F U Q 0 • Z Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard • Industry leading Wire Mounts available for all o a Man Heavy Duty UR-60 Rail ° v Z m . • • • • • • • UR-60 rail profile provides increased span o capabilities for high wind speeds and snow ry 0 Sin ra• - • • • • • • • cu loads o N uJ • Taller, stronger rail profile includes profile- (N N w Clamps • - specific rail splice and end cap o o > >are a • All existing mounts, module clamps, and `n 0 m W compatible accessories are retained for the same great Z z W both rail profiles install experience F ® G lL � o O o Start 1wallinri 'l 11, day,_­ 'm Quality. Innovative. CrRESOURCES snapnrack.com/resources - ° O O WLLJ MountingSnapNrack Solar • . - - . •. ' 1-- z ZDESIGN snapnrack.com/configuratorlabor resources and improve • • safety. W N W � �WHERE TO BUY snapnrack.com/Where-to-buy D oO > dQ 7 JZ N LZ W W o Ul c (19Z 3 NW W W O� F Ln 0 r4 fV Z C' LD ©:powMECHANICAL SPECIFICATION W .' ^ :a)-- powered ered by -- ---- - --- -----'--- ---- i r f A� '-1 to+nl.rt 74Onx41ln. 1_26in(including Name) ------------ W • DUD ® _ {1879rnm 1045mm 37mm) _._.- .__.. ,...n.n.n --- __.-. _.- -_-_..__ Pru•• uA�ux,-., Z 48.51bs(27 0 kg) _ _ _. f fl 0.13sn(_3 7mm)tnem,euy pre-VT essed glass with anti-resection techndb9Y I7___ ..w.�°..,:..w„,.,.•,1 r«» I 1 *•w CJ..-, COmppsrtA l4m nws+. �' • _ T Black anocLed aluminum W - _ (n�LL O C3 -- - - - - ----- 6 22 rrgnocrystapne O ANTUM Polar ttatt ce11s © �- 0 E J­'ti•'llnx 2.09-3981nx1.26-236ln 0�b9071iA E1'1 > O (53-I01mm x 32-60mm Ib-]8mm)•IP67,w4h bypass ckWes «rm.c,-'n LUj)1 4mm2 Solar cable; ()z 49.2n(I2bOmm)() 492n(I?bOmrr) """`-.CJ ••�-•-..w-• I twit 0 rJ . J -nncr Staub[,MCA;IP68 -. -_.::._._._- r LL O LA s CE LLn 3 Y O ELECTRICAL CHA14ACTE-RISTICS LL k.0 Ln 386 390 396 400 406 1,_ O Ln VtANCE AT STANDARD TEST CONDITIONS,STC'(POWER T<,. t;^.ICF+5W!-O V! OJ O 0-1 111 P_ IWI 38b 390 395 •II:J 405 EEY ShotC+rcurtCwrenF I� (A} -111-0-4 1107 1130 l ;4 .1170 O ''� t.0 E Coen C rrcuit Voltage- - Va IVJ 4b.19 45.23 45.27 45.'30 45 34 G O OC } YR ---._.__.._... j 6 _.._.. .............. ,.� - / 0 g Cir.antMMPP I- JAJ 10.59 10.65 1071 1071 1083 CO Z / Vat ago et MPP V•rar IVJ 38.38 386? - 3688 3713 3739 Ln 7 U rwaawran _ _, _ ,_- _-- - _-- In J U rD Eft d cY 4 1%) x19.6 ;19.9 2201 2204 120.8 ' r�.,.r I MINIPAL A pERFORMANCF AT NORMAL OPERATIIJG CONDITIONS.IdMOT W I- W W Q 2021 Power AMVP P (W] 788.8 292.6 2963 300.1 303.8 -1 CJ Warranty 0 CELLS - ---- ---- - --- W Q �r�l F Short Circuit Current IK - JAI 8-.90 8.92 8.95 8.97 POC _ U UJ F Oen Circuit Voltage Vpc IVJ 4:1.117 4?e5 4789 47.7:' L -I Q O _._ I- L) In f C ant atMPP Ira IA] 8.35 841 846 -8.51 BREAKING THE 2(:r:',F.FftC1ENCY BARRIER - ------ ------- -- Z TEJ _Va a�-at MPP Vim, IV] ,3459 i 3481 _--3503--- 35.25 3548 _NII) Q ANTUM DUO Z Technology with zero gap cell layout - -- axntu boosts Measu amen.to a axes P ,:3%,I, V 5%el STC 1000W/,W,25 2C.AM'5 xcn dN0 rg to_C e. 4-3 CVl 80 ;m Osererr ern NM ' AM 15 module efficiency up to 20.9 X. 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE THE MOST THORr:)11C=H TESTING PROGRAMME IN 1•HE NDUSTRY °' At least 98%of-nal power du,mg "° Q CELLS is the first solar nodule manufacturer to pass the most comprehen- " ',,.I Yea Tr-sane,min.0.5% - sive quality prograrwne in the IndJ1 nom na w-,upustry.The new-Oual'ty Control?ed PV-of • deg.aero,m,u. At+oast 93.5% ,, fo 10 years At tine[xlependent certification institute TUV Rheinland. z 9 bast 86%01 nprtrna power up to • 75 yeas • e Z ". Cl INNOVATIVE ALL-`N1RSHER TECHNOLOGY � Al;data wtrnn---t tdemno Optimal yields.whatever the weather w4h excellent . as.Full--ala.In accomanca w th tens • a.. ..o ... d F the war•Mly ns of the O CELLS low-light and ter-,petature behaviorseo o,tw-re tions vou„o;; i� R O co-m•y O fl'1 ,' ,....•.r«.... e•.w+ro ws.. • +rainy TYPicd rnpdub per b,rnanca+user low aCNnCe candnxyl.in a O ...ww,.. »e........x,• - ENDURING HIGH Ip£n:I ORMANCE amoansrn to STC ctsndnorx(25•C.t0o0Wlr-ir) U�� � � U 1. I_ terra teed security with Anti l_3D Technology. ._ _ _. .._. -- -....-- ---- - --- - ----- - -- -. _.-.- ------------ ----- v In ech y y ogy.Anti PID TEMPEPATURE COEFFICIENTS ^ - z W v Technology'.Hot-Spot Protect and Traceable Quality Tra.G-. ---- - --- --- - 00 M O a 1'Y./KJ 4004 NM Ts p atura dell ant f v Q d (%IKI 027 d O -•t -.._..: ..- ._ ._._._.-. ...__ _. _...-..-.. _.-._ 1 +.n M ansa Op athe9 7 rno+ tus: O+ 4 tI 109i5A(43t3 C) O EKTREMEWEATiIERNATING K�__-- _ --- -- r'4 r4 = ren /,L H,gh-tech aluminurn alloy frame,Certified for =' o rti u! high snow(5400 Pa)and wWind iotlds(4040 Pa) PROPERTIES FOR SYSTEM DESIGN � ('14N -^ � - .. .r (V) 1000(ILC)/1000(UL) C;essII b C4 \ 2�) A RELIABLE INVESTMENT IA DCJ 20 I Y'PL: � C) ty m _.._ / �f Inctusive 25-year product warranty and 25-year 1tt,s 7b(3e00Pe)/_b5(7680P4) P -rte o r•r,;, Te p.=ra+::.c 40°F up to•t85°r- o Ln Q I.1 .(,( linear perfo!mance weranty'. post 1t3(b400Pa)/84(4000Pa1 `'' ( 40°C up to°BS°C} bp Z 3 LLNJ -APT testi d!- atlug:o IEC/TS6<904-12015.rt+etnaC A(-1500V B6•tl - - Q Q �, IL••`� m 'Sae tlalA b'r.Rl pin reY'rx'U'ine,rtwmarion QUALIFICATIONS AND CERTIFICATES PACKAGING INf ORMATION Y VL aim C1 C(np11AM n/yy 1rV'�-'I r { �w ouGsh C xad4q W-r�y 1.^er..ann LL EccuL.roteIrcat7aozote, _____ _-- THE IDEAL SOLUTION FOR: a 7CA n 433k1 48 r 1Et,6 os i4 :•t MPA1a^trM 9.893".ISI»IS s� (/ f-C�,�„U$ \ I _ _ 1940mm 1100mm t210 rxn 7S;kg -pallets pallet_ _nrc:ules U. k - u Neta:I,:stananon m It tions must tie followed.Sea the nsretlatron and opwalmg manual or contact mr Lechrik al service depertment for furrier information on opo,oved inslalla!on and uea of ] } J n this oroducr rr1Q� z > LL W It Engineered in Germany Q, CELLS Na 1.11cELLSAmericalea ul Mm W Q - .Sure 1400.trvina.CA 92618,USA I TEL.1 94 9 748 59 96,,1 EMAIL Inowry�us q-cells com 1 Wit www.9-celk:us . 11 p Q = F- In L9 F- Z W 0 [n Q LO z 3 N W W W Ln0 e..1 0 O1 m :3r t\ W Q - 0 m ', .,,- ENPHASE � IQ�3 Series Microinverters W lo INPUT�DATA loci 108 60 2 US 108PLUS 72 2' US 10814-77 2 US 108A 72-z-US 108H 240 72-2 US - r z Commonly used module pairings' w 235-350 235-440 260-460 295 320-540- 295-500 - Module U1' Module compatibility 60-cell/120 half-cell 60-telt/120 half-cell and?2-cell/144 half-cell O L MPPT voltage range v 27-37 29-45 33-45 36-45 38-45 36-45 ('�LlOperating range v 25-48 25-56 (f1 m L 1 i Min/max start voltage v 30/48 30/58 c > 0 Max input DC voltage V 50 60 1 1 1 GN C . W V) O _ Max DC current(modulo Isc] A 15 W m O Overvoltage class DC portS- LL U DC port backfeed current mA 0 W i 7 Lr) PV array conRgLL alien 1x1 Ungrounded array,.No additlonal DC side protection required:AC side[•=,tcctimn requires max 20A Der branch._i c_. > io Lf) OUTPUT DATA!ACi log 60 2 US z U L!1 a Orn ~ Q1 C: ak output power VA 245 300 330 3E;6 364 366 (•y Y -6 � Max continuous output power VA 240 290 325 349 380 360 CEO U O ry) Nominal(L-U voltage/range` v 240/211-264 206/183-250 _jOJ 00 } e 00 Z Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 0 U ro w Nominal frequency 141LflLn z 60 J Extended frequency range Nz 50 88 F- W W Q IQ8 Series Microinverters W Z J " Max units per 20 A(L-U branch circuits /6 13 11 t7 10 9 � W ❑ L) [n �— Q (n Our newest I08 Microinverters are the industry's first grid-forming microinverters Total harmonic distortion .5% U O with split-phase power conversion capability to convert DC power to AC power Easy to install Overvoltege class AC port 111 I— Z efficiently.The brain of the semiconductor-based microinverter is our proprietary Lightweight and compact with AC port backfeed current mA 30 application-specific integrated circuit(ASIC)which enables the microinverter to plug-n-play connectors Power factor setting 1.0 operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-085 lagging and grid events,alleviating constraints on battery sizing for home energy systems. (PLC)between components Peak efficiency 97.5 97.6 97.6 97.6 97.5 -1 Faster installation with simple CEC weighted efficiency 97 97 97 97.5 97 9- Z two-wire cabling Night-time power consumption on mw 80 ❑ Enphase 25 ct F High productivity and reliability O IL IL Ambient temperature range -401C to•601C(-40'F to•140°F) O Produce power even when the r` CU Relative humidity range 4%to 10096(condensing) Lf) CU grid is down DC Connector type MC4 00 +O W Part of the Enphase Energy System.108 Series 108 Series Micromve+tars redefine reliability More than one million cumulative O -' O O Dimensions(lAxWxD) 212 mm(8.3•)x 175 mm(6.9-)x 30.2 mm(1.2') N 1— N Microinverters integrate with the Enphase 10 standards with more than one million hours of testing N = r0 Battery.Enphase 10 Gateway.and the Enphase cumulative hours of power-on testing. Weight 1.08 kg(2,38 lbs) ON N N App monitoring and analysis software. enabling an industry-leading limited warranty Class II double-insulated �, N — U) W of up to 25 years. enclosure Cooling Natural convection-no tans > Q Optimized for the latest high- Approved for wet locations res � m , Q powered PV modules Acoustic noise at 1 m <60 dBA O ❑ W Pollut on degree PD3 W Z up::r CERTIFIED Grid-forming Enclosure Class II double,risulated,corrosion resistant polymeric enclosure Q 0 m Complies with the latest Environ.category/UV exposure rating NEMA Type 6/outdoor advanced grid support Connect PV modules quickly and easily to 108 Series Micrornverters are UL Listed as 108 Series Microinverters us. he included PV Ra Shut Down E w ment and conform Remote automatic updates for n9 Rapid q P CA Rule 21(UL 1741-SA).UL 62109-1.UL1741/IEEE1547.FCC Part 15 Class B.ICES-0003 Class 8,CAN/CSA-C222 NO.107-1-01 ^ O-DCC-2 adapter cable with plug-n-play MC4 with various regulations.when installed the latest grid requirements Q jp Q Q connectors. according to manufacturer's instructions. Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014.NEC 2017.and NEC 2020 section Q. Configurable to support a wide 890.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems.for AC and DC conductors.when installed accordrig to range of grid profiles manufacturer's instructions. F- 0 W W G• 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo.108 microinverters. Meets CA Rule 21(UL 1741-$A) (1)The 108H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See � Z W and other names are trademarks of Enphase Energy.Inc.Data subject to change. requirements the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input F F— W DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal d required by the utility.(5) (n IY ❑ tO85E-DS-000201-EN-US-2021-tn-19 Limns may vary.Refer to local requirements to define the number of microinverters per branch in your area. I08SF-DS-0001-01-EN-US-2021-10-19 Z ❑ J Z (n L9 Z W f- o 0� LO Q L9Z 3 N W