Loading...
HomeMy WebLinkAbout47740-Z ouff� Town of Southold 12/20/2022 o J P.O.Boz 1179 53095 Main Rd Southold,New York 11971 �,xxr CERTIFICATE OF OCCUPANCY No: 43699' Date: 12/20/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 520 Green Hill Ln., Greenport SCTM#: 473889 Sec/Block/Lot: 33.-3-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/23/2022 pursuant to which Building Permit No. 47740 dated 4/26/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Lewis Rev InterVivos Trt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47740 5/264022 PLUMBERS CERTIFICATION DATED Au or ed g ature oSu n c TOWN OF SOUTHOLD BUILDING DEPARTMENT y 1 TOWN CLERK'S OFFICE SOUTHOLD NY ��Ol •`,v BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47740 Date: 4/26/2022 Permission is hereby granted to: Wyandanch RE Corp 1325 Locust Ave Bohemia, NY 11716 To: install generator as applied for. At premises located at: 520 Green Hill Ln., Greenport SCTM #473889 Sec/Block/Lot# 33.-3-10 Pursuant to application dated 3/23/2022 and approved by the Building Inspector. To expire on 10/26/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector ^a°t i So Town Hall Annex �r� 1 (� �r r Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ,. �� sean.deviin(c-town.southold.ny.us Southold,NY 11971-0959 cou BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Wyandanch RE Corp Address: 520 Green Hill Ln city:Greenport st: NY zip: 11944 Building Permit#: 47740 Section: 33 Block: 3 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Gen Ready License No: 2740ME SITE DETAILS Office Use Only Residential X Indoor X Basement Generator X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 22kW Generac w/200A Whole House Transfer Switch, 30A Load Shedding for AC Notes: Generator Inspector Signature: Date: May 26, 2022 S.Devlin-Cert Electrical Compliance Form �a0f SOUIyo �..:( �](,/ ® 2-V � l ( l w TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 I -SPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]` -INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL `[ ]' FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL-(ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: DATE INSPECTOR �O Of SOGIyO ti �o * # TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [. ] 'FOUNDATION 1ST [ ] ROUGH PLBG. ] FOUNDATION 2ND [ , ] " INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE &-CHIMNEY " [ ]. FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ­]'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE dG y� ZL 'INSPECTOR 0E jqo�ot1� SOUI,yo� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 JNSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN LATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: o�,�► C•O. DATE © ��'�ZZ INSPECTOR ' FIELD INSPECTION REPORT DATE COMMENTS, FOUNDATION(1ST) y -------------------------------- FOUNDATION(2ND) t� ` P = rn ROUGH FRAMING& y PLUMBING 'U INSULATION PER N.Y. STATE ENERGY CODE to ` i od y� 2 y� FINAL - ADDITIONAL COMMENTS W7. 23 � rfc *v10 1 cr) rn 121 c�� rty J-) l ov y g�FFOI y =off coGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT ar Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PE MIT ,OF.,Office Use Only PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety.Incomplete IF MAR 2 ?1 2022 _ applications will not be accepted. Where the'Applicant is not the owner,an BUILDING DEPT Owner's Authorization form-(Pagey2).shall be completed: TOWIN OF SOUTHOLD Date:2/28/2022 OWNER(S)OF PROPERTY:- Name:Robert Fischer sCTM#soo0-33-3-10 Project Address:520 Green Hill Lane,Greenport, NY 11944 Ph. '#:,631--76779933-#:,631Email:rfis641100@yahoo.com ,-767-9933,w _.- __-_ ..._ - _ _.. . _._. Mailing Address:520 Green Hill Lane,Greenport, NY 11944 CONTACT PERSON: Name:Ed Reiff/ Gen Ready Mailing^Address:128 Pulaski,Road,_Kings Park, NY 11754 Phone#:631-544-0400 _.. - __.... Email:office@getgenready.com DESIGN PROFESSIONAL INFORMATION: Name:N/A Mailing Address:N/A Phone#:N/A Email:N/A CONTRACTOR INFORMATION:- Name:Ed Reiff/ Gen Ready Mailing Address: 128 Pulaski Road, Kings Park, NY 11754 Phone#: 631-544-0400 Email:office@getgenreadY.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther 24kw generator installation. tnl I ('v \ ' �. �, <{Fn p� $7,500.00 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residence Intended use of property:Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable.Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for'removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. = Application Submitted By(print name):Ed Reiff / Gen Ready BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) Ed Reiff / Gen Ready being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor/Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or.owners,.and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of !"` 20 22. Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I Robert Fischer residing at 520 Green Hill Lane Greenport, NY 11944 do hereby authorize Ed Reiff / Gen Ready to apply on a n of Southold Building Department for approval as described herein. Z Owner's Signature Rosemary Faiella Robert Fischer NOTARYPUBM,STATEOFNERYORK Registration No.OIFA4901831 Print Owner's Name Qualified in Suffolk County Commission Expires July 21,20.Z S 2 F04 BUILDING DEPARTMENT Electrical Inspector TOWN OF SOUTHOLD 04 ® Town Hall Annex- 54375 Main Road - PO Box SO f Go Southold, New York 11971-0959 ti p� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCa�southoldtownny.gov — seand@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/12/2022 Company Name: Gen Ready Name: Ed Reiff License.No.: ME-2740 email: office@getgenready.com Phone No: 631-544-0400 [Z]I request an email copy of Certificate of Compliance Address.: 128 Pulaski Road, Kings Park, NY 11754 JOB SITE INFORMATION (All Information Required) Name: Robert Fischer Address: 520 Green Hill Lane, Greenport, NY 11944 Cross Street: Homestead Way Phone No.: 631-767-9933 Bldg.Permit#: email: rfis641100@yahoo.com Tax Map District: 1000 Section: 33 Block: 3 Lot: 10 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Install a 22kw natural gas generator. Check All That Apply: Is job ready for inspection?: YES 0 NO Rough In Final Do you need a Temp Certificate?: YES [Z]NO Issued On Temp Information: (All information required) Service Size Ph 3 Ph Size: 2Lti`7�A #Meters Old Meter# Mdv Rdcptbd Rdcpthd Qdbnnrdbs Trrcdcf cpt rrc Nudcgd' c # Underground Laterals 1 2 H FramePole Work done on Service? Y) N1 Additional Information: �`` 00 C11- 1k--T PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xisx of F04 BUILDING DEPARTMENT- Electrical Inspec or #'4p 2 3?® TOWN OF SOUTHOLD )o N4,0IN v Z� Town Hall Annex- 54375 Main Road - PO Box 1 Nsco ae oU moo: Southold, New York 11971-0959 (o 4 ® ®� Telephone (631) 765-1802 - FAX (631) 765-9502 ®1 �� roaerrAsoutholdtownny.gov — seand@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/12/2022 Company Name: Gen Ready Name: Ed Reiff License No.: ME-2740 email: office@getgenready.com Phone No: 631-544-0400 01 request an email copy of Certificate of Compliance Address.: 128 Pulaski Road, Kings Park, NY 11754 JOE SITE INFORMATION (All Information Required) Name: Robert Fischer Address: 520 Green Hill Lane, Greenport, NY 11944 Cross Street: Homestead Way Phone No.: 631-767-9933 BIdg.Permit#: 4'7 7 �O email: rfis641100@yahoo.com Tax Map District: 1000 Section: 33 Block: 3 Lot: 10 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Install a 22kw natural gas generator. Check All That Apply: Is job ready for inspection?: YES 0✓ NO Rough In Final Do you need a Temp Certificate?: YES 0✓ NO Issued On Temp Information: (All information required) Service Size G 3 Ph Size: 70 A #Meters_ Old Meter# .Mdv Rdcpibd RdcpflDd QdbnnTWbs TrTcdcf cit rrc Nudcgd' c # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: 0C-QoehoA ,f I F— ALJ i I(' @t &L�t� Iii Prf C PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments �� GREEN HILL LANE' (50' WIDE) EP20.02 EP20,88 EDGE OF PAVEMENT EP21.32 +CL20.51 +CL20.79 I +CL21.54 EP20.12 EDGE OF PAVEMENT EP20.84 I EP21 14 GUY ' :i VN 20tzs °57'50" W 145.60' �s n ; PROPOSED SANITARY • �� SYSTEM° sw y i / MjN Maj ;� MIN i� 18.5' 13.5' '" o ° 0 6.0 w c 0 7.33 15.17 ° r . w PROPOSED tit 3.5' FOUNDATION o y ~ ci X2.0' ;p 23.5' lk. cc o o z r PROPOSED yPS'�IMMING ,p OOL 20 s40 n �a PROP. CLEARING LINE & SILT FENCE e POOL OFFSET 5' MIN. r MAP LINE o b m 4' CHAIN LINK FE. c S 20"24'50" E 145.60' 3.5E r MAP OF ROCKCOVE ESTATES EJIQSTING RESM N Workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid-Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier la.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured MR.FAUCET SERVICE COMPANY INC DBA INSTALLGAS.COM 516-752-1234 201 NORTHWEST DRIVE SUITE 1 FARMINGDALE,NY 11735 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required If coverage Is speclRcailylrmited to or Social Security Numberi 12851548 certain lmtbns In New York State,l e.,Wrap-Up Pofky) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed In Box"l a" Southold,NY 11971 DBL338240 3c.Policy effective period 04/30/2020 to 04/29/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following Gass or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named Insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/23/2021 By (Signature of insurance carriers authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer _IMPORTANT: If Boxes 4A and 5A are checked,and this form Is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Pians Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of histher employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only Insurance carders licensed to write NYS disability and paid family leave benefits Insurance policies and NYS licensed Insurance agents of those Insurance carvers are authorized to Issue Form D8-120.1.Insurance brokers are NOT authorized to Issue this form. DB-120.1 (10_17) �I�IIPmim1u2iioi1i�ii(�10iu171)i�llll� NYS1 F 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 New York State Insurance Fund I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 112851548 lo KEEVILY,SPERO-WHITELAW INC.500 MAMARONECK AVENUE HARRISON NY 10528 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER MR.FAUCET SERVICES CO.,INC. TOWN OF SOUTHOLD PAUL E.MUHS,AS LICENSED PLUMBER 53095 ROUTE 25 201 NORTHWEST DRIVE,SUITE#1 PO BOX 1179 FARMINGDALE NY 11735 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBERPOLICY PERIOD DATE G 1149 296-4 359197 05/01/2021 TO 05/01/2022 03/30/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1149 296-4, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS'COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT PAUL E MUHS SECRETARY LAURA A MUHS 20F2 _ MR.FAUCET SERVICES CO.,INC. THE POLICY INCLUDES A.WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND10R MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS.ENTERED INTO A WRITTEN CONTRACT WITH-OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 464794119 ��II 1111 0000000000009 9802959®®mo 271 Form WC-CERT-NOPRINT Ve,sion 3(08292019)[WC Policy.1j4929641 41 U-26.3 [060000p8D00091980295]10001-0000314929611fatG1[15603.6211�p•�RT�1Ia3�6001[ '`,`R E0 CERTIFICATE OF LIABILITY INSURANCE DATEIMMI202 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELYAMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement: A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTIErKat Mistretta NAME: National Insurance Brokerage of New York,Inc. PHONE (631)273-4242 Am No): (631)273.8990 175 Oval Drive IL ADDRESS: KMistretta@nibony.com INSURERIS)AFFORDING COVERAGE NAIC 0 Islandla NY 11749 INSURER A: Merchants Mutual Insurance Co 23329 INSURED INSURER B Mr.Faucet Service Company Inc INSURER C: dba Instaligas.com&Paul E.Muhs INSURER D: 201 Northwest Drive INSURER E. Farmingdale NY 117354920 INSURER F: COVERAGES CERTIFICATE NUMBER: 21-22 MASTER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT;TERM OR CONDITION OF ANYCONTRACT OR OTHER DOCUMENT WITH RESPECTTO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECTTO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSLTR TYPE OF INSURANCE I POLICY NUMBER POLICY F MMyDp P LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S 1.000'000 DAMAGE IFJKFNIhU CLAIMS-MADE ®OCCUR PREMISES eoecurmaw S 500,000 Contractual Liability MED EXP onepawn) S 15,000 A BOP1048048 05!0112021 05101/2022 PERSONAL&ADV INJURY S Included GENLAGGREGATE UMITAPPUES PER: GENERALAGGREGATE S 2.000,000 POLICY®JECTT LOC PRODUCTS•COMPIOPAGG S 2,000,000 OTHER: S AUTOMOBILE LIABILITY COMBINED S $INGLE LIMB F,e='=' D WS BODILY INJURY(Par person) $ OWNEDSCHEDULED AUTOS ONLY AUTOS BODILY INJURY(PerecddeM) S HIRED NON-OWNED PROPERTYDAMAGE S AUTOS ONLY AUTOS ONLY Per aecdenl S UMBRELLA UAB OCCUR EACH OCCURRENCE S EXCESS LIAB HCLAIMS-MADE _ AGGREGATE S DED RETENTIONS S WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE' ER ANY PROPRIETORIPARTNERIExECU IVE ❑ NIA E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory In NH) - E.L.DISEASE-EA EMPLOYEE $ It desedtw under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,nu4 be nuachod If mom spew Is mqulmd) The Certificate Holder Is included as additional Insured A.T.I.M.A with respect to General Liability as required by Written contract/written agreement per the policy terms,conditions and exclusions. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELNERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 PO BOX 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2018103) The ACORD name and logo are registered marks of ACORD ,�V .0 N,\ --41 ��4�,M "�'0",OW 1EN� -06 4-111i�ln ��-0-041 A a I, - 01 _g w4n 2MI-1- ............ ztl 7� IL S. P4 A Suffolk County Department of Labor, Licensing & Consumer Affairs V VETERAN 11 1788 S MEMORIAL HIGHWAY HAUPPAUGE, NEW YORK -32128 10/08/2002 No. MP DATE ISSUED: . ...... H� SUFFOLK COUNTY M 51 -a%"i as ter Plumber License jj.5 I J), a" Ill This is to certify that Gerard J Aaron M Mr Faucet Service Compa I-V ny Inc DBA Ali doing business as N having given satisfactory evidence of competency, is hereby licensed as MASTER PLUMBER in accordance N� with and.subject to the provisions of applicable laws, rules and regulations of the County of Suffolk, State of Av, -v New York. 11RUJI NOT VALID WITHOUT Additional Businesses 14�f DEPARTMENTALSFAL Wz- '31 Installgas.com AND A CURRE NT CONSUMER AFFAIRS ID CARD Suffolk County Dept.of irs Labor,Licensing&Consumer Affa 0 4 -p, 1, MASTER PLUMBING Name GERARD J AARON Rosalie Drago U S e S S N,am a This cerfiries that the Commissioner Mr Faucet Service company Inc DBA by the County Of Suffolk bearer is duly licensed 21�8 t I—Y License Number:100-3 a �j\i-v gm Rosalie Drago Issu6d-. 1010812002 A I Commiss;oner ............. Expires: 1010112022 ® CERTIFICATE OF LIABILITY INSURANCEDATEIMMroD1YYYY) 04/20/2021 'HIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS :ERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. 'HIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED tEPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. MPORTANT: If the certificate holder is an ADDITIONAL INSURED, the pollCy(ies)must be endorsed. if SUBROGATION IS WAIVED,subject to the arms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to,the ertificate holder in lieu of such endorsements. JDUCER CONTACT NAME FARM FAMILY CASUALTY PHONE FAX 859 CONNETQUOT AVENUE ADA/C NO Ext: A/C No: 2M L ESS: ISLIP TERRACE,NY 11752 INSURER(S)AFFORDING COVERAGE Nac a URED 631-277-7770 INSURER A: FARM FAMILY CASUALTY INS.CO. 13803 INSURER B: STATE INSURANCE FUND 36102 GENREADY, INC. INSURER C: SHELTER POINT 81434 128 PULASKI ROAD INSURER D: KINGS PARK NY 11754 INSURER E: IVERAGESINSURER F: CERTIFICATE NUMBER: 125539 REVISION NUMBER: HIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD 4DICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS •ERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, XCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE INSD WVO POLICY NUMBER POLICY EFF POLICY EXP MM/DD MM/DD LIMITS X COMMERCIAL CLAIMSGENERALLIABWTY 3152X1390 05/07/21 05/07/22 EACH OCCURRENCE $ 2',000,000 CLAIMS-MADE 1X OCCUR PREMISES(Ea occurrence) $ 100,000 MED EXP(Any one person) $ 5,000 GEN'LAGGREGATE LIMIT APPLIES PER: PERSONAL&ADV INJURY $ 2,000,000 X POLICY JECaT El LOC GENERAL AGGREGATE $ 4,000,000 OTHER: PRODUCTS-COMP/OP AGG $ 4 OOO 0-0-0— AUTOMOBILE OOAUTOMOBILE LIABILITY $ 3152C4335 05/07/21 05/07/22 (Eaaaeid.D?iNGLEuMIT $ 1,000,000 ANYAUTO AUTOSNED X SCHEDULED BODILY INJURY(Per Person) $ AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS X NON-0WNED AUTOS (Per a.dent) E $ X UMBRELLA UAB $ X occuR 3101 E1933 06/03/21 06/03/22 EACH OCCURRENCE EXCESSLIAB CLAIMS-MADE $ 1,000'000 AGGREGATE S 1,000,000 DED X RETENTION$$10,000 WORKERS COMPENSATION $ AND EMPLOYERS'LIABILITY YIN CERTIFICATE T E ANY PROPRIETOR/PARTNER/EXECUTIVE" N/A ATTACHED OFFICERIMEMBER EXCLUDED? E.L.EACH ACCIDENT $ (Mandatory in NH) 1046 681-1 If yes,describe under E.L.DISEASE-EA EMPLOYEE S DESCRIPTION OF OPERATIONS below E.LDISEASE-POLICY LIMIT $ NYSDBL DBL 265291 01/01/07 INDEFINITE STATUTORY ;RIPTION OF OPERATIONS 1 LOCATIONS f VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) ITIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF SOU--HOLD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 MAIN ROAD ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE RD 25(2014101) ©1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 4% YS ' F New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 .AAAAA 112763133 VINCENT C DALEY 859 CONNETQUOT AVE ISLIP TERRACE NY 11752 0 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER GENREADY INC TOWN OF SOUTHOLD 128 PULASKI ROAD 54375 MAIN ROAD KING PARK NY 11754 SOUTHHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 11046 681-1 494738 05/20/2021 TO 05/20/2022 5/4/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1046681-1, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF-COM/CERT/CERTVAL.ASP.THE NEW. YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT EDWARD S REIFF VICE PRESIDENT ANDREW J REIFF OF GEN READY INC-A TWO-PERSON CORP. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:167265012 1-26.3 workers'rnrE CERTIFICATE OF INSURANCE COVERAGE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GENREADY,INC. 631-544-0400 128 PULASKI ROAD KINGS PARK,NY 11754 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required ifcoverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-up Policy) 112763133 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) TOWN OF SOUTHOLD ShelterPoint Life Insurance Company 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD, NY 11971 DBL265291 3c.Policy effective period 01/01/2022 to 12/31/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,1 certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 1/6/2022 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) sIIIIIIDB-120.1 (12-21) N I Su=ffalk Countyt.aept. a►fi Labor, Licensing S Consumer Affairs MASTER ELECTRICAL LICENSE Name EDWARD S REIFE { Business Name chis certifies that the GENREADY, INC. bearer is duly licensed by the County of suffolk License Number: ME-2740 Rosalie Drago Issued: 0510111:980 Commissioner Expires: 05/01/2022 Mr. Faucet Service Co., Inc. InstallGas.com 201 Northwest Dr. Farmingdale, NY 11735 Robert Fischer 520 Green Hill Lane Greenport, NY 11944 MMR GENERATOR J')01 ' r ° gVp �- APPRO YED AS N/OTTE! 7qED �L DATE: B.P.4 L b FEE: S' BY: ::m:: NOTIFY BUILDING D PARTMENT AT 765-1802 8 AM TO 410M FOR THE FOLLOWING INSPECTIONS 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL CONS-7,7�ir-!r)N MUST BE COMPLE FE ALL CONSTRUCT"!', 41ALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR L,- E 0r R11C AL DESIGN OR CONSTRUCTION ERRORS. { � �' HIP-0-HIPRED COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF . .1,`'J-l0I D TCM T 11CTEES USE �8 UNLAWFUL WTHOUTTFATIFKAT OF OCCUPANCY f • GENERAC ro:, 'gyp, GUARDIAN® SERIES _ � �' � r�-1 Residential-Standby Generators Air-Cooled Gas Engine r , INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039.3(Aluminum-Bisque)-20 kW 60 Hz • ]True PowerT"Electrical Technology G007042-2,G007043-2,G007042.3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209.0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-llne multilingual digital LCD Evolution`"controller j (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fig'connectivity • System status&maintenance interval LED indicators • Sound attenuated•enclosure. ..� • Flexible fuel line connector — +j �l • Natural gas or LP gas operation GENERAC• i 0 5 Year limited warranty 0 Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.' 'Pdust be located away from doors,windolvs,and fresh air intakes and in accordance with local codes. T � l ops:/lrise#ssNri.org/%6raryrD rec#aryOfLlsiedProducts/ e I us or C US Q I ry - Cor,�a•c#ion,ndusU1ls73_ObC 204 13204-0t-01_Rev9.pdf `,., LISTED [V Note:CETL or CUL certification only applies to unbundled units and units ppackaged With limited circuit switches.Units packaged with the Smart Switch are'R or UL certified in the USA only. i FEATURES 0 iNNOVATIVE ZI IN=IE DD�81G11 G 81Gi}NULI5`f TING are at the heart of Gen- O SOLID-STATE,FREQUEKY CONIPENSKi l O VOLTAGE REGtd ATH311: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme,operating conditions. loads to the engine.Digital voltage regulation at.0%. O TRUE I'DWI:R"ELECTRIC;"�TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network j form produce less than 5%Total Harmonic Distortion for utility qualitypower.This provides parts and service know-how for the entire unit,from the engine to the smali- allvws confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable.speed HVAC systems. O TEST CMTERIA: O GENERAC T5ANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC I. SYSTEM TORSIONAL.TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility, O tomb t;L'lyll( 'Cmf8.ITIU'IT a';FREE with select Guardian Series Home standby O PW RIME-t,°" TRANSFER 8W1 l T CH: The Generac PWRview Automatic Transfer generators,Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smanphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service,With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. wG E N E R A G h>���, @,!, GENERAC' PROMISE.R O M I S E• g�. f f GENERAC" 20/22/24 kW Features and Benefits i • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine f life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. I • High temperature shutdown Prevents damage due to overheating. • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced"phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to=1%prevents damaging voltage spikes. j • UL 2200 listed For your safety. TrsrrGtGV Srt RCh-(H a��ItcableP • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be Installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. lrh�Ffi�i��.s�!b's7tl Yom:�tv6i�Y� �t��g�z�i'srabt2�, • PWRvie,v energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWIRview mobile app Access dally energy intelligence and insights. • AUTO]MANUALIOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Se-=1ed,raised buttons Smooth,weather-resistant user interface for programming and operations. 0 Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. I • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. s • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. , t � I( ' GENERACm 20/22/24 kW Features and Benefits Unit _ • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade-muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. •,Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Ins 5a!WfiaTn-Sy stern 0 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. ti • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generatorExercise/Run and Total Hours Review-the generator's complete protection profile for exercise hours and total hours. • -Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. ( • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location, 4 - I - c - - r4 a i j - i " I { L GENERAC' 20/22/24 kW Specifications 1-2on Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G00704H G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated m-inn co<tunuous power capac ty(LP) 20,000 Watts* 22,000 Watts' 20,000 Watts' 22,000 Watts' 24,000 Walls' Rat=a maximum continuous power capacity(NG) 18,000 Watts* 19,500 Watts* 18,000 Watts' 79,500 Watts' 21,000 Watts' Rated voltage 240 Rated maximum continuous 1020 current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100187.5 i oW ha 70c D>s:lomon Less than 5% !'car„bre,c.rcu::areaer 90 amp 100 amp 90 amp 100 amp 100 amp Prase 1 N�,..erof,rotor;m:es 2 'ZS "El _XY 60 Hz Power tactor --- 1.0 Ba¢ary Fez -_7e"R(na Ind-A-0) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Urt;w_.g`.(ID!':g) 448/203 466/211 436/19B 445/202 455/206 Dimerslos(LxWxH)in/c,,n 48x25x29/121.9x63,5x73.7 Sour:0L°cut Li c2(A)at 23 it(7 m)Wan generator operating at normal load•• 67 67 67 67 67 Secem Oc.w In d'3(A)at 23 tut(7 m)watt generator in Quiet-Test"low-speed exercise mode** 55 57 55 57 57 xe rase twat,on- - 5 min Eng,rw yp3 GENERAC G-Force 1000 Series Y,;.=,,ter Of Cytx'_rs 2 D.s":E--r4,,., 999 cc Cyd -;block Aluminum w/cast iron sleeve Val:a,arye- lt Overhead valve ptm;niter, Solid-state w/magneto Ga•,-rrmr sys:em Electronic Ccrores_s,an ratio 9.5:1 Starter 12 VDC O l acaa:y Including filter Approx.1.9 qt/1.8 L O:e a::n;rpm, - 3,600 j Ftie;C4n6z.,i;xG^^, xz-;Vic;gas `l/ta(VAr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8,52) 327(9.26) 287(8.13) 306(8.66) L baa pmpana tta/tir(gaU [Loan] 112 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57) 1/ Full Load 130(3.56)[13.48] 142(3.90)[14.77] 136(3.74)[14.15] 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,1 D-12 in water column(2.49-2.99 kPa)for LP _ULFor BTU content mul9p'y Olra x 2500(LP)or 1"3mr x 1000(NG).For Megajoule content multi I m3/hr x 93,15( or m3/hr x 37.26(NG). _ �^arahx�is [WO-line pian tett Multi!ingi. l LCD Simple user interface for ease of operation. MXa a,,rzons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. f,ANUA, Sean with starter control,unit stays on.If utility fails,transfer to load takes place. OF Steps unit.Power is removed.Control and charger still operate. eacy to Ru J!.'a°n:trance messages Standard Engine ran haws indication Standard Programmable start oetay betvreen 2-1500 seconds Standard(programmable by dealer only) utility Vomge LOW.elun to Locality ad]Mble(brownout setting) From 140-171 V/190-215 V Future Set Capable Euerclser/Exercise set Error warning Standard RcyAtzmVldauxerance lags 50 events each i Erg.na start sea.-nae Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter tact!-out Starter cannot re-engage until 5 sec after engine has stopped. S.Tert iia:ery Crarger Standard Cra;ger FauttUssing AC via Standard Low Sa:ery/3a:ery Problem Protect'.on and Battery Condition indication Standard Awu^aac Voi;zge Regulator,w_m Over and under Voltage Protection Standard Unde,-FreGaerry/a rloacVStepper Cvercurrent Protection Standard Sale' Fusea/Fuse Problem Protection Standard ALm-malic Law Oil Pressure/Hlgh Oil Temperature Shutdown Standard Overcrar Overspeed(Qi:72 Hz)/rpm_Sense Loss Shutdown Standard High Engine-Ti em-perature Shutdown Standard i internal FauMnawrect Wring protection Standard Common external fault capability Standard Feld upgradable hrm[rare- Standard ( "Sound levels are la:wrl from the Irons of the generator.Sound levels Man from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying em:reercy pati-r for me=union of the utility power outage.NO overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).'Maximum Mlovolt amps and current are sua;ca to arm flitted by such factors as fuel BTl1/ragajode content,ambient temperature,altitude,engine povver and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea I ti J;and also will decrease approxitrately 7%for each 10''r(6'C)above 60'"r(16 C). i I I � I .r _ GENERAC' I 20/22/24 kW Switch Options uModel G007039.1,G007039.3(20 kW) i • Intelligently manages up to four air conditioner loads with no additional hardware. _ -, (1007043.2,0007043-3(22 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 with Smart.Management Modules(SMMs). VoOage rating(VAI)T,;" 120/240 96 0 Electrically operated,mechanically-held contacts for fast,clean connections. utility voltage monitor(fixed)' Rated for all classes of load,100%equipment rated,both inductive and resistive. -Dro our 65% • 2-pole,250 VAC contactors. - R666to lJtjlity`_ - _ _ ,'_Approx_13 • Service equipment rated,dual coil design. Exercises ..weekly for 5 minutes' - Standard <ER or UL listed '. Standard • Rated for both aluminum and copper conductors. Enclosure type NEM-AtULSR • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit#tiieaker protected.,; „ : 22,D00 i • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 'Function of Evolution controller Exercise can be set to weekly,bi-weekly,or monthly Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 W1 I W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95_ 76.43 26.67 34.18 17.5 "I I Wire Ranges { Conductor Lug Neutral Lug Ground Lug 2.50 MCM-#6 350 MCM-#6 2/0-#14 -OEM- -'---w2--� i . i PLY�6Vl8ir Autdmafin TESlisf er�&%Mtth YcintuYes Model G001210.0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. Current rating(amps) — _ V_ 200 • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large(240 VAC)loads can be managed when used In conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up B0% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections. Refurri io utility' -. -,.._ _-_- _ - -_Appipt 13 sec • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes' Standard • 2-pole,250 VAC contactors. EfL"or UL listed :____._.--______ ;Standard • Service equipment rated,dual coil design. Enclosure type NEMA 3R Circuit braake_r protected _- _--_ 22,000 • Rated for both aluminum and copper conductors. Lug range zso MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can he set to weekly,bi-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. —w1 Dimensions v 200 Amps 120240,1 o Open Transition Service Rated Height Width "2 H' H1 H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 1 34.18 17.5 Wire Ranges eer,ua —w2- Conductor Lug Neutral Lug Ground Lug 250MCM-#6 -350MCM-#6 2/0-#14 l! L! GENERAC* 20/22/24 kW Available Accessories _ ,Model# Product Description . I ,GG05819-0 ''26R Wet Cell Battery Everystandby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). 1007101 0 'Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls beiow 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). I .1007102-11 " 01 Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). 6007103-1 -,Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where !I heavy icing occurs. 1005621-0 'Auxiliary Transfer Switch The a-li ary transfer switch contact kit allows the transfer switch to lockout a single large electrical load that may not be :Contact Kit needed.Not compatible with 50 amp pre-wired switches. 0007027-0-Bisque -Fascia Base Wrap Kit^' 'The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22124 kW) ;appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 1005703-0-Bisque , -_ Oi _r_ -r +Touch-Up Paint Kit If the generator enclosure is scratched or damaged,itis important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 50064$5-0— -Scheduled Maintenance Kit,Gerieraes scheduled maintenance kit provides'all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). 6007005.0 }� Wi-Fi LP Tank Fuel Level -The Wi-Fi'enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor 1P tank's fuel level is an important step.In verifying the generator is ready to run during an unexpected power failure.Sta- ,tus alerts are available through a free application to notify users when the LP tank is in need of a refill. ;GO070D0-0(50 amp)'Smart Management Module.`6 rt Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- ;13007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) .the overall size and cost of the system. G007169-0 46 LTE Mobile Links Geliular The Mobile Linkfamily of Cellular Accessories allow users to monitor generator status-from anywhere in the world,using j 6007170-0-Wi-RI Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethemet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. I ;G0h7220-0-Bisque Base Plug Kit- M Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured :appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC " (46.0 Inj 46.0In] 0007038-1 696471074185 I1in G007038-3 696471074185 0007039-1 696471074192 G007029-3 696471074192 G007042-2 696471074208 727.2 mm (29.6 Nl G007042-3 696471074208 G007043-2 696471074215 z G007043-3 696471074215t 0 0 GG07209-0 696471071511 11 0007210-0 696471078220 648— - 1232- - - 125.51n] - 148.5.1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. I GENERACO Generac Power Systems,Inc.• S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com -� l C2020 Generac Power Systems,Inc.All rights reserved.All specifications are subleot to change without notice.Part No.A0000937814 Rev.B 07/30/2020 &'r �i {cel, AP RO ED AS NOTED DATE: B.P.# -7 qd FEE: 334,�� BY; NOTIFY BUILDIN 'EPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - MUST BE COMPLE,r Fu- "). ALL CONSTRUCTi:_-�• �-,-!ALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FC'n DESIGN OR CONSTRUCTION ERRORS. E-LLE(r(,-'TV$pC L CTg0bM COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODEES AS REQUIRE—) Ak![—) CONDITICY\JP;, O °�- — ..w.,-. '",'.,'.�..u, I� std n 7P�'•. ���� 1711!7 GENERAC GUARDIAN® SERIES 2 0 �24 k 9" Residential Standby Generators Air-Cooled Gas Engine i INCLUDES: Standby Power Rating I G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power"Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz P - •. Two-line multilingual digital LCD Evolution',controller G007209-0,G007210.0(Aluminum-Bisque)-24 kW 60 Hz (English/Spanish/Frenct/Portuguese), • 200 amp service rated transfer switch available .4 Electronic governor 0 Standard Wi-Fig'connectivity • System status&maintenance interval LED indicators t • Sound attenuated:enclosure �d • flexible fuel line connector s Natural gas or LP gas operationGENERAL' ; ..'° - 1 ., i • , 5 Year limited warranty. iA • Listed and labeled by the Southwest Research Institute allowing Installation as close as 18 in(4.57 mm)to a structure.' 'Must be located array from doors,windows,and fresh air intakes and in accordance with focal codes. 0 ps/lessets.svri.org/t'6rar„Dr;ectcr�O;lJ'stedP;odacisJ 105 us or COUS of �' n � �[V unK Lersrlctiflnlydusfr,,,` 3_Gtrr_20 13204-01-01_Rey9.pdf LISTED o Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES ffl$aOlfATc'JE'Et 9bIE. ESICiJ9 HISORGI'S aE5T139L are at the heart of Gen- 4 SOLID-STATE, FREQUENCY COVAPERSATED VOLTARE REGULKRON: This erac's success in providing the most reliable,generators pbssible: Generac's G- slate-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. } 4` TRUE PC4.m-e5_u_—C7 flX—1ECHN13LOGY:Superior harmonics and sine wave 0 SINOLE SOUR0 SERVICE RESPONSE from Generac's extensive dealer network ' form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operatiom of sensitive electronic equipment and micro-chip based est electronic component. appliances;such as variablespeed HVAC systems. i '3 TEST. RITERIA: C CENsPMC TRANSd�-iF SlViTUIES:Long life and reliability are synonymous with PROTOTYPE TESTED NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. i 1,10BI'LE11IN ire=,INECTIVITY:FREE.with select Guardian Series Home standby C PWFIVIE:M> 3Fi USFER 51ilTCtl: The Generac PWRview Automatic Transfer generators,Mobile Link`Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating.status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under I account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and i Mobile Lirik;users are taken care of before'the next power outage, low cost tool which helps save money over the life of the generator.Included with IIII model G007210-0. ”' GENERra R BRAC' IP,R0MISE- ns� `06P W ?M� , � GENERAC� 20/22/24 kW Features and Benefits { Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings.help,the engine run cooler,'reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylfnd'er.walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system- Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. j �eri5r�,i:cr • Revolving field. Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. 0 AL-tomaje voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R . Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. ur"SJ�%Sif�b:+R�'_i�r'aeei��`i7f:'Cf�I,'��lapiiC�fof?� • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile, • PVIRview mobile app Access daily energy intelligence and insights. • AUTO/MANUALrOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. -• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. 0 Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. •_ Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute, • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel,costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. f + - - — _- - - 1 : GEINERAC°- 20/22/2..4 kW Features and Benefits • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Encfosed'critical grade-muffler Quiet,critical grade muffler is mountedinside the unit to prevent injuries. { •- Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. j •- 14 in(35.5 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. s • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. 0 Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. ! • .',feather information Provides detailed local ambient weather conditions for generator location. e t i jy, A GENERACa 20/22/24 kW Specifications �rs�l�r�to: Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 6007043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 I(W) Rated r='nwm continuous power capacity(LP)_ 20.000 Watts* 22,000 Watts* 20,000 Watts' 22,000 Watts' 24,000 Watts' ;a d maximum continuous power capacity(NG) 16,000 Watts' 19,500 Watts* 18,000 Watts' 19,500 Watts' 21,000 Watts' Rated voltage 240 Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 i,7zl Harmonic Drsviion Less than 5% 61ain I:ne c;rcua Breaker 90 amp 100 amp 90 amp 100 amp 100 amp Pitase 1 ci rc:dr oc!e3 2 a;sc AC Uacmerry 60 Hz Pur=r actor - — - 1.0 3aaaay;x, zr:(na irriid=d), 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Ut�twcgtu(io/kg) 448/203 466/211 436/198 445/202 455/206 Dtrncslos(-xWxIi)in/cm 48x25x29/121.9x63.5x73.7 Some id ctrput in d3(Aj ai 23 It(7 m)Mtn generator operating at normal load— 67 67 67 67 67 Scxsrd os.oi;in dB(A)at 23 ft(7 m)with generator in OWet-Test'low-speed exercise mode** 55 57 55 57 57 Exerc,se C atioi -- Gtt�intr - Ecyine GENERAC G-Force 1000 Series Af_,;mer o cyl:,Zers 2 D:sp:ac_, =M 999 cc Ly;rncer b{ou Aluminum w/cast iron sleeve Vats arc.g-,Meru Overhead valve ly^,v#c,t System Solid-stale w/magneto Goser,u:r srt:m Electronic Coracesssor ratio 9.5:1 Sty ger - - - - - - -- - ._ 12 VDC 6t capacg tmcluclrig filter- Approx.1.9 qt/1.8-L r 0:: .ng rpt m 3,600- i Fuca crcts.�:�aca Y.ai:dai Gas n3/hr(MIN) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(g.26) 287(8.13) 306(8.66) Lrq-d p ocarx Ps/nr(gaV/2(Load 1Load 87(2.37)18.991 92(2.53)[9.57] B6(2.36)(8.95] 92(2.53)19.571 1/ Full Load 130(3.56)[13.481 142(3.90)[14.77] 136(3.74)(14.15] 142(3.90)[14.771 Ncte:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel Inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,IG-12 in water column(2.49-2.99 kPa)for LP as For BTU coreent mml5piy Y3/hr x 2500(LP or 3/tu x 1000(NG).For Megajeule content,multi ly m3/hr x 93.15(LP or m3/hr x 37.26(NG). =-- - Two-!.ria p:a7 tw tn:tiilntgual LCD Simple user interface for ease of operation. Mode tutors:AUTO Automatic start on utility failure,Weekly,Bi-weekly,or Monthly selectable exerciser. �A;UpL Stan with starter control,unit stays on.If utility fails,transfer to load takes place. OF Stops unit.Power is removed.Control and charger still operate. 3 acy to Eut,^hz.a;et-ance messages Standard -EVa-ra,hours trlwcation Standard Program,.able scar delay be:ween 2-1500 seconds Standard(programmable by dealer only) uttktyYWtage LosJReturn to 05ty adjustable(brownout setting) From 140-171 V/190-216 V Future Se:Capable Exerciser/xer ise Set Error warning Standard RtirVAfamUMaintenance tags 50 events each EGgta2 sra sequerre Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Sa,er indk�r rt Starter cannot re-engage until 5 sec after engine has stopped. Sia¢32-ery Charger Standard Cm maria;..,!' isseg AC waming Standard Lcv a::ery/5a`:ry Ptob!an Protectfon and Bakery Condition indication Standard A,:,, M Vokage Reguiatrort with Over and Linder Voltage Protection Standard Uncer-Frequency/Ordcad/Stepper Overcurrent Protection Standard Safe;y Fused/Ftxe Problem Protection _ _ Standard `.-orattc Lori Oil Pressure/High Oil Temperature Shutdown Standard O;Wrcran,%0verspead(@ 72 Hz)/rpm Sense Loss Shutdown - Standard ki-gh Enyfre Temperature Stlutdown Standard Internal Fauft/monect Wiring protection _ _- _ Standard Common external tuft capability Standard Feld upgradable ftrmwa a Standard -`Sou d lev�eis are m'!in trap the frora of the generator.Sound levels taken from'-other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying Emcrden0y prntiar to ME duction of tha u5!iiy parer outage.No overload capability is available for this rafting.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilwit amps and current are sLaAato and l.rrited ny such actors as fuel BiU rnegajode content,ambient temperature,altitude,engine pourer and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea la a;and also will dacrease aoprozin ately 1%foreach 10 IF(6°C)above 60 IF(16`C). i ! I GENERACmm 20/22/24 kW Switch Options 5;c+t�;aG'tGd[�t9tfaf5fc310 T8c7Fi"�fDPi'71tLhGG$tl1ES Madel G007039.1,G007039.3(20 kW) j • 13007043-2,13007043-3(2 Intelligently manages up to four air conditioner loads with no additional hardware. - -. k - — • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 with Smart Management-Modules(SMMs). Voltage fat r g(VACj, • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)' • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick--up 80% -Dropout 65% - • 2-pole,250 VAC contactors. Return to tltit(ty` i _ _ _ _ -A_pprax.-13sec • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes' Standard • Rated for both aluminum and copper conductors. EosUC listed__ _ Standard Enclosure type NEMANL 3R _ • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuilbreake�ptotacted 22000' i • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range f 4250 MCM-#6 'Function of Evolution controller � Dimensions Exercise can be set to weekly,bi-weekly,or monthly 200 Amps 120/240,1e j Open Transition Service Rated Height Width Depth I ! H1 H2 W1 W2 in 26.8 - 30.1 10.5 13.5 6.9 cm 67.95 76,43 26.67 34.18 17.5 He H' 1 Wire Ranges ConductarLug NeuVallug Ground Lug I 250 MCM-A 350 MCM-#6 2/0-#14 DEPTH' W2 s i,Aview dtitat;tGlaC t0i15$t! stJ?"s�d1'S Fa$q� 5 Model No.of poles" 2, 46 Integrated PWRview monitor provides.real-time energy usage data through PWRview app. -Current rating(amps) _ -` __J,_.-200 • Intelligently manages up to four air conditioner loads with no additional hardware. ;Voltage jating(VAOj.":m .: `. •• 120%2x0,_10:,_ • Up to eight additional large(240 VAC)loads can be managed when used in conjunction utility voltage monitor(fixed)' with Smart Management Modules(SMMs). -Pick-up 80% Dropout 65% • Electrically operated,mechanically held contacts for last,.clean connections. (6eturri!6 Utility'___ ___. __ __-_ —Approx,l3 sec: _ • Rated for all classes of load,100 A equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes' Standard • 2-pole,250 VAC contactors. Efl oof Uljisted _ w� _ _ _ $tandaid • Service equipment rated,dual coil design. Enclosure type NEMA 3R CUcuit breaker protected- - 22,o0D • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6- • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly wE 4 Heavy duty Generac Contactor is an ETL recognized device, ^ _ I I Dimensions t 200 Amps 120/240,16 Open Transition Service Rated i Height Width fe "•' H1 H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 1 6.9 i, cm 67.95 76.43 26.67 34.18 1 17.5 Wire Ranges LDEPTH a —H2 Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 $50 MCM-#6 2/0-#14 i 13 i ! GENERAC" 20/22/24 kW Available Accessories _ Model# Product Description 0005819-0— 26R Wet Cell Battery' Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). :0007101-0 T Battery Pad INarrrler Pad warmer rests under the battery.Recommended for-use if temperature regularly falls below 0 IF(-18°C).(Not nec- essary for use with AGM-style batteries). i 6007102-0 Oil Warmer Oil warmer slips diredtly over the oil filter.Recommended for use if temperature regularly fails below 0 IF(-18°C). ' GG07103-1 — Breather Warmer -T Breather warmer is for use in extreme cold weather applications,For use with Evolution controllers only in climates where heavy icing occurs. i G0066ff1-0 - Auxiliary Transfer&kch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. 0007027-0-Bisque 'Fascia Base Wrap Kit —iThe fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 'G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 6006485-0 Scheduled Maintenance Kit Generac,s scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). i G007005-0 _ ^ Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. I 6007000-0(50 ampj Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce i (100 amp) the overall size and cost of the system. I G007169-0-4G LTE Mobile Link`s'Cellular The Mobile Linkfamily of Cellular Accessories allow users to monitor generator status from anywhere in the world,using 1 'G007170-0-WI-Ftf Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethemet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. I G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC (15.t(25.1 ,z,amm int 6007038-1 696471074185 G007038-3 696471074185 00070391 696471074192 G007039-3 696471074192 G007042-2 696471074208 72,a— (ae.e mf 0007042-3 696471074208 G007043-2 696471074215 171 11 .1 G007043-3 696471074215 a o 0 G007209-0 696471071511 — 0007210-0 696471078220 wamm ,232mm (15.5.1 148.51n1 LEFT SIDE VIEW FRONT VIEW Dimarsionsshow are appro)dmate.See installation manual for e)actdimanslons.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. I G E N E RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 4—.2020 Generac Pov er Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.B 07/30/2020 I l