Loading...
HomeMy WebLinkAbout15037-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. Certificate Of Occupancy No....Z.1.5.1.9..5 ........ Date January 13, 1987 THIS CERTIFIES that the building ..... .A.c..c .e.s.s. 9 .r y..n.u..r .s.e.r.y., .b.u.~. 1..d./.n.g.: .......... 29925 MAIN ROAD CUTCHOGUE Location of Property ............................................................... House No. Street Hamlet County Tax Map No. 1000 Section ...1.0. 2. ...... Block ...0.2 ........... Lot 16 Subdivision ............................... Filed Map No ......... Lot No .............. conforms substantially to the Application for Building Permit heretofore fried in this office dated ..... .J.u.n.e...1.8.,...1.9.8.6., . pursuant to which Building Permit No... 1.5. .0 .3.7.Z. ............ dated ...~1 ~ .n.e..2. 7. o..1.9. 8..6 ........... , was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ......... ..... .A.=.¢. ? .~.~.o.~..y..~.~.~. ? ?Fy., .b.~.i.t.d..~ ?.g.. ........................................... The certificate is issued to LEFFERTS P. EDSON (SANTAS CHRISTMAS TREES) {o wrier, le~ Itma~x of the aforesaid building. Suffolk County Department of Health Approval ..... 8 ./.A .................................. UNDERWRITERS CERTIFICATE NO ............. N..7 .8.0.3.5. .2 ............................. PLUMBERS CERTIFICATION DATED: N/A Rev. 1/81 TOWN OF $o~'r~OLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Y. BUILDING PERA~IT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) N°. 15037 Z Dote / Permission is hereby granted to: ~ ..... .~.....~..~..~:......~.~....,,,~,. ..................... .~.~......u...:..~.:.....~./..~..,..~ ............ .~..ct ;,~ - ~ ot premises located at ...e~ .................... ..~.~.......~-.. ............................. .... Coun~ Tax Map No. 1000 Section ..... L..~.....D~.. ....... Block ...... ..O......~.. ...... Lot No ....... ./../,~. ........... pursuant to application doted .... ~4..~?_../...~.. ........................ , 19.a..IR,.,*' and Building Inspector. Fee $....~....~./..:.~~ approved by the Building Inspector Rev. 6/30/80 FORM NO. 6 TOWN OF SOUTHOLD Building Department Town Hall Southold, N.Y. 11971 765- 1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY Instructions A. This application must be filled in typewriter OR ink, and submitted mm..-..--- to the Building Inspec- tor with the following; for new buildings or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2.Final approval of Health Dept. of water supply and sewerage disposel-{S-9 form or equal). 3.Approval of electrical installation from Board of Fire Underwriters. 4. Commercial buildings, Industrial buildings, Multiple Residences and similar buildings and installa- tions, a certificate of Code compliance from the Architect or Engineer responsible for the building. 5.Submit Planning Board approval of completed site plan requirements where applicable. B. For existing buildings iprior to April 1957), Non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, buildings and unusual natural or topographic features. 2.Sworn statement of owner or previous owner as to use, occupancy and condition of buildings. 3. Date of any housing code or safety inspection of buildings or premises, or other pertinent informa- tion required to prepare a certificate. C. Fees: 1. Certificate of oc_cupancy $5.00 2. Certificate of occupancy on pre-existing dwelling $15.0 0 3. Copy of certificate of occupancy $1.00 4.Vacant Land C.O. $5.00 5. Updated C.O. $15.00 Date .......................... New C on s t r u c t i on Old or Pre-ex isting Building Vacant Land Location of Property ............................................................. House No. Street Hamlet Owner or Owners of Property ............................................................ County Tax Map No. 1000 Section ...t~.<~..~. .... BIock...~....~.. ...... Lot...Z~. ........ Subdivision.. ....Filed Map No ........... Lot No .............. Permit No./. ~"~;3~. 2-Date of Permit . .~'/~.Applicant ,~/4 f,7~,~' .......... ...... Health Dept. Approval ........................ Labor Dept. Approval ........................ Underwriters Approval ........................ Planning Board Approval ...................... Req~Jast for Temporary Cert f cate ..................... Final Certificate ....................... Fee Submitted $ ............................. ragu lations, n.,. ~o-,o-~e ~.. 3//~ 3 THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY ~,,, Ap.,,~.,,o. No.o./,,~ N 780352 THIS CERTIFIES THAT o~ly the eleetrie ~ ~n, ~n ~, (~e ~), ~ite ~ A~me, ~, N.Y. (S~ta' s ~s~ ~S examined on and found to be in compliance with the r~uire~nents ~f this B~rd. FIXTUEE OUTLE/S FIXTURES RANGES COOKING DECKS OVENS EXHAUST FANS DRYERS IRJTURE AF~UANCE PEE~RS TIME CLOCK5 UNIT ~EATEES MULTI-OUTLET DIMMERS SYSTEMS NO. OF F~I~T SERVICE D~"ONNECT OTHER APPARATUS: U/H 6.-400 Watt, QTZ 2-1500 W~tt Electric Haan Heaters: 1-.5~ 1-Lite Pole with %-1500 Watt Qtz. S E R V I C E A. WG- NO. OF HI.LEG A.W.G. A. WG. 4/0 4/0 G~ Electric Box 215 Southold , N.Y. 11971 Lic. 578E This certificate must not be altered in any manner; return to the office of the Board if incorrect. Inspectors may be identified by their credentials. COPY FOR BUILDING DEPARTMENT. THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IH ANY MANNER. ANTHONY B. TOHILL MICHAEL T. CL)FF'ORD A~THO~¥ B. TOH~J., P.G. ATTORNEYS AT I~xW 12 FIRST STREET P. O. BOX 1330 r'- RIVERHEAD, NEW YORK 11901-090~r-::~,--:" May 6 Mr. Gary Fish $outhold Town Hall Building Department 53095 Main Road Southoldr NY 11971 Dear Mr. Fish: I have been retained by Lou Edson to examine the zoning status of Santa's Christmas Tree Farm and I am in the process of doing that. By this letter I am advising you that to the extent appropriate I will be asking the Town to consider an amendment to the Zoning Ordinance to allow the use to continue. Verv truly yours, Anthony B. Tohill AST/bb TOWN OF SOUTHOLD OFFICE OF BUILDING INSPECTOR P.O. BOX 728 TOWN HALL SOUTHOLD, N.Y. 11971 RE: Santa's Tree, 29925 Main Road, Cutchogue, NY To Whom This May Concern, We are unable to complete your Certificate of Occupancy because.of the following reasons. /Z/ An application for Certificate of Occupancy is not on file. /Z/ No Underwriters Certificate on file. The check is(outdated/l~L /Z/ No Health Dept. Approval on file. /Z/ No final inspection has been made. Please contact our office on this matter. Thank you for your cooperation. Building Permit # / ~-- O 3 ~ Z Building Dept. ***/~/ No Plumber Solder Certificate on file. ( all permits involving plumbing being issued after April 1,1984 ) ANTHONY B. TOHILL NICHAEL T. CLIFFORD OF COUNSEL 1%~/qTHONY B. TOHILL, P.G. ATTORNEYS AT LAW 12 FIRST STREET P. O. BOX 1330 I~IVERHEAD, NEW YORK 11901-0003 May 15, 1997 Mr. Gary Fish Southold Town Hall Building Department 53095 Main Road Southold, NY 11971 Dear Mr. Fish: With respect Santa's Christmas Tree Farm, please be advised that we have today ordered a survey of the property from Van Tuyl which will now be used to submit an application for rezoning of the southerly portion of this property. I will continue to advise you as we take each step in the rezoning application process. Very truly ~ Anthony B. Tohill ABT/bb Town Hall. 53095 Main Roaa P. O. Box 1179 SouthoId, New York 11971 Fax (516) 765-1823 ph (516~ OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD February 26, 1997 Mr. Lewis Edson PO 1526 Southold NY 11971 Re: Grace Edson Christmas Tree Farm ~ Retail Store SCTM # 1000-2-16 Dear Lou: Let t~ds letter serve as a written follow up to our conversation on Monday, Februay 24, 1997 regarding the agricultural storage building at 30105 Main Road Cutchogue, Tax Map ~102-02-16. As we discussed on Monday it has been brought to the attention of the Building Department by the PlaDnlng Board that the use of the above described building is in violation of its certificate of occupancy. The CO clearly indicates the building is classified as an agricultural building, reference CO #Z19311 and Z15195. Enclosed are copies of these COs. I trust they aid in clarification. As a result, the Planning Board "feels that the Building Department should revoke the current Certificate of Occupancy and issue, a violation". After conferring with Laury Dowd, the Town Attorney, on this matter and also speaking with Ed Forrester, the Town Investigator, and yourself I feel it to be counter productive and not in keeping with a philosophy of voluntary compliance to issue any violations at this time. Instead I respectfully request of you a reply letter as to your intentions and plan of action to resolve this matter. I also request a meeting with you on the site so I can see first hand what type of operations you are conducting. Please keep in mind that I take the recent correspondence from the Planning Board seriously and find merit in their concerns and recommendations. I trust tl-ds letter encourages and ~o~va~c~; you to respond in a timely fashion so this issue can be resolved to the satisfaction of all parties involved. I wait for your anticipated written reply. Planning Department Town Attorney Town Investigator Supervisor Jean Cochran Respectfully, Southold Town Building Department Building Inspector PLANNING BOARD MEMBERS RICHARD G. WARD Chairman GEORGE RITCI-IIE LATHAM, JR. BENNETT ORLOWSKI, JR. WILLIAM J. CREMERS KENNETH L. EDWARDS Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971 Fax (516) 765-3136 Telephone (516) 765-1938 PLANNING BOARD OFFICE TOV/N OF SOUTHOLD FROM: TO: RE: DATE: Bennett Orlowski, Jr., Chairman~ Gary Fish, Building Inspector Grace Edson, Christmas Tree Farm and Retail Store Main Road, Cutchogue Zoning District: Low Density Residential R-80 SCTM# 1000-2-16 February 11, 1997 The above retail store is conducting a business in a building that has a Certificate of Occupancy for an accessory nursery building CO # Z-15195, and a CO # Z-19311 for an addition to existing agricultural building. After repeated attempts to correct this situation have been made to no avail, the Planning Board feels that the Building Department should revoke the current Certificate of Occupancy and issue a violation based on the fact that a retail store is not permitted by the CO. BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST []ROUGH PLBG. [ ] FOUNDATION 2ND []INSULATION []FINAL [ ] FRAMING REMARKS: DATE ~INSPECTOR BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ]ROUGH PLBG. FOUNDATION 2ND [ ]INSULATION FRAMING [ ]FINAL BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION FRAMING [ ] FINAL FIELD INSFECTION FOUNDATION -- (lsd. FOUNDATION ( 2nd ) ROUGH FRAME & PLUMBING INSULATION FERN. STATE ENERGY CODE Ye C Of~IMEt~TS ADDITIONAL COMMENTS: 'FORM NO. 1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL $OUTHOLD, N.Y. 11971 TEL.: 765-1803 Examined . .~. ,~,~4'Y~ .~..'/...., 19 ~ .~. Disapproved a/c ..................................... (Building Inspector) APPLICATION FOR BUILDING PERMIT BLDG DEPT TO~,~q',~ 0~ SOUTHOLD ~ ?Y ~-- .3 .~-~ e c e ive d ........... ,19... Permit No.}..~. .~.-.?.~... .~ U INSTRUCTIONS a. Tkis application must be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli- ,cation. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit 'shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whaCk*er until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, h~q~i~g code, an_~l ~, and to admit authorized inspectors on premises and in building for necessary inspe~ (Signature of applicant, or~,a,,~, ;7 .... vc. ratiz..) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. ........... ................................................................... Name of owner of premises .... ~...~ .~'...,,f~..~".~...c'~....~..~,~ ..... ~.....~...~...~....'~..,,,~... ..................... (as on the tax roll or latest deed) If applicant is a corporation, signature of duty authorized officer. (Name and title of corporate officer) Builder's License No .......................... Plumber's License No ......................... Electrician's License No ....................... Otl,,~ ,,aue ~ License No ...................... 1. Location of land on which proposed work will be done .................................................. ........................ ......... ....... House Number Street Hamlet County Tax Map No. 1000 Section .... /..~.. ~ ..... Block ...... ~ ........ Lot..~..~. ........... Subdivision ..................................... Filed Map No ............... Lot ............... (Name) State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy /~. ,~,,~ ~...~..,~...~.. b. Intended use and occupancy .. ~....,~...~...~.f'. ....... ~..~. ~.-~..-~..-.-.~.'~ .,~.,~-(7 .'..~...~..~'./~.~.~.'.~.~ ....... 3~ Nature of WOrk (check which applicable): New Building ....~"... .... Addition .......... Alteration .......... Repair .............. Removal .............. Demolition .............. Other Work ............... ~ ~ ~ ~l'~, (Description) 4. Estimated Cost . .iC:~. x:~/:..~.t~..~. ..................... Fee ...................................... · (to be paid on filing this application) 5. If dwelling, number of dwelling .units .... ~..~. ..... Number of dwelling units on each floor.. If garage, number of cars . . . .'~..'~.. ' ............ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use ..... . .~.-~..-. ........ 7. Dimensions of existing structures, if any: Front ..... ~.dd ....... Rear .... .>f'..~ .......Depth..~..d. ......... Height ...J..o.: ....... Number of Stories ..... ~ ................................................. Dimensions of same structure with alterations or additions: Front ..... %'~. · .'~.... Rear ............... Depth ...................... Height ................. Number of Stories / ..-./ ~- ............ .) - . ~ .... 8. Dimensions of entire new construction: Front ....~-. ~...._________________~.... Rear .....--2'~-. ~'.. ~..... Depth .~.~.. ~.. ....... Height ...~..-.~. ....... Nu_mbrer of Stories .... ,/ ...... ~ ......................................... 9. Sizeoflot: Front .... /./. ~.' ........... Rear.. ~ .~..,~.'~. ............. Depth ....?~..O/ 10. Date of Purchase ...... ./..~.. ~..ff~.. ........... ~am~e of Former Owner .............. 1 1. Zone or use district in which premises are situated... ,'~--.q.~../. ?..-r..-.~:.< .77'.,~../ .......................... 1 2. Does proposed construction violate any zoning law, ordinance or regulation: ~ .~. ................. 13. Will lot be regraded ...... .~/..~ ........ · .......... Will excess fill be removed from premises: Yes No 14. Name of Owner of premises ...e'7..Od../,,Yo,,~.~..~,~....,~.. Address .~. ~.../.4'.~/..~. .... ...~Phone No.~i~.'7..~ Name of Architect .'~.4 ~,../~?..'~.. ........... ~,~/',~d',,.~...j. ~Address .~.~.~./././~..,,;~.o'..~.,~./~ .dff,.a,Phone No.g~. f. ~4d~'.' i .~.'~.' ~... Name of Contractor . ~r. ~.~..,~. ~ ............. Address .... : .............. Phone No ................ 15. Is this property located within 300 feet of a tidal wetland? *Yes ..... No..~... · If yes, Southold Town Trustees Permit maybe required. PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dimensions from property lines. Give street and block number or description according to deed, and show street names and indicate whether interior or corner lot. ;TATE OF NEW YORK, ~'OUNTY OF ................. S.S ................................................. being duly sworn, deposes and says that he is the applicant (Name of individual signing contract) bove named. te is the (Contractor, agent, corporate officer, etc.) ,f said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this pplication; that all statements contained in this application are true to the best of his knowledge and belief; and that the ~ork will be performed in the manner set forth in the application filed therewith. worn to before me this 'c, TM .... ,. .... ......... . ., ~t~.. ..... ? (Signature of apphcant) ~m r. xpires M~Icn ~u, ~' ~ MAP OP'/..AND CUT6,LIO~U~ ~[~TE6, I~. 455.40 ,,'. ~'o' , o '¥-3=;~.--- .................................... OUTCIWOGUE E6TATE$, /NC. CUT'CA/OGUE Flee ~MORTON BUILDINGS GENERAL SPECIFICA'I:IONS LAMINATED COLUMNS - No. 1 or better southern yellow pine nail laminated 3 member 545 columns used in Morton Buildings are pressure treated below grade to a retention of .8 pounds per cubic foot with Chromated Copper Arsenate Type III, Oxide type, as listed in Federal Specification TT-Wo571J. The treated 9ortion of the column embedded in ground shall be laminated with stainless steel nails. FOOTINGS AND ANCHORAGE - Column holes are dugs4 feet min. depth below grade and ready-mix concrete pads or dry concrete mix pads are poured in place (note plans for size & type). Two galvanized steel angl~ base anchors are placed 1' from bottom Df column. Additional concrete mix is poured around base of column then backfilled with soil and compacted at 8" intervals. S'~LASNGOARDS - Splashboards are No. 2 or better southern yellow pine 2"x8" S2S and center matched, pressure treated to a net retention of .4 pounds per cubic foot with Chromated Copper Arsenate Type III, Oxide type, in accordance with American Wood Preservers' Association Specification C2. One rn~ is furnished for building on a level grade. FRA~IING LUMBER - Side nailers are 2"x4' S4S SPF 2100 MSR spaced approximately 30" D.C. with all joints staggered at attachment to columns. Roof purlins are 2"x4" S4S No. 2 SPF or better on ~dge space~ apprnxi~ately 20" O.C. All other framing lumbe~ is standard grade or better. ROOFTRUSSES - Factory assembled with 18 mr BO gauge galvanized steel truss plates as required and g~aded kiln dried lumber as specified. In-plant quality control inspection is conducted under the auspices of the TR! inspection bureau. Trusses are designed in accordance with current standards and specifications for the stated loading. BRACING - 0.O35"x1-1/4" high tensile steel construction X-bracing in all unobstructed corners· Lateral truis ties and end bracing as needed., SIDING PANELS - 0.019" min., G90 zinc galvanized steel with an additional baked-on silicone finish. Color is I mil thick on exterior. ROOFING PANELS (PLASTISOL) - 0.019" min., GgD ziQc galvanized steel. The top side of the panel . shall have a baked-on plastisol coat with a minimum paint thickness of 4 mils. TRIM - Die-formed trim of 0.019" min., GPO galvanized steel on gables, ridges, corners, base, windows and doors with same paint finish as roofing and siding panels. GU~)F_~S - 5" box type gutters, color to match trim, on both sides of the building. HEATINGr PLUMBING, VENTILATION~ AND ELECTRICAL WORK - By others, net part of these plans. NOTE: MORTON BUILDINGS GENERAL SPECIFICATIONS apply unless indicated differently on specific job drawings or supplemental infurmatiun. 335 PL 2/86 ~ OCCUPANCY OR USE IS UNLAWFUL Wll'BOUI' CERiIRCAIE OF OCCUPANCY APPROVED AS NOTED NOTI~f BUILDING DEPARTMENT 7S5-1802 9 AM TO ~- PM EOR THE FOLLOWING INSPECTIONS: 1 FOUNDATION TWO REQUIRED FOR POUBEO CONCRETE 2 ROUGm FRAMING & PLUmBiNG B, INSULATION 4-, FINAL CO~STRUC~ION IVlUS? SHEET -INDEX SHEET ~ DESCRIPTION I OF .5SPEC/F/CATIONS r~ SHEET INDEX ~ OF .5COLU/v/N PLAN ¢ ELEVATIONS ~ OF..5ELEVATIONS // SIDEWALL SECTION 4' OF `5 DETAILS `5 OF .5- 4Y' L COMM. 5. C.-TRUSS I hereby certify that this plan and specification was prepared by me or under my direct persona! supervision and that I am a duly registered Professional Engineer and competent to prepare this document. DATE ~-4 -~ REG. NO. %1,1 (~ DRAWN BY: A,~ O. CHECKED BY: REVISED BY: DATE: DATE: DATE: LEWIS ~c,'-,m -- ~ UTCHO NE_W ~Y?RK I°pE'cEPHILLtPSBUR~'-NJ I SCALE: JOBNO. 73-2465 P , SHEETNO. `5 ~ 'JE I~T-A- RiB 4' ?OF~cH HEADEF~ ~A 5 ? ~LEVA TIO~ B~,5'E COLU~'~ P~LL^~ --(~b- 3o&¢ BP, IHEA DEP, /2_ :RI& G~BLE TR }M -- 5,A P_I ~,~OP~ ?-H ELEVATION 2'x6" BEV. SR90 FASCIA COVER PRECUT SOFFIT-- 2"x6" OVERHANG NAILER' PLA ST/ ~o&- HI-RIB STEEL ~ \ 2"x4" PURLINS &o' O.C. ~ (NO. z SPF) ~ -2"x4" BEV. PURLIN ~I~'~-ff~~/~ 5" O,G, GUTTER (2) 1/2"x5-1/2" M. BOLTS & (8) 20d R,S, NAILS /e-OGRADE TO HEEL HI-RIB STEEL 3-2"x6" LAMINATED COLUMN ROWS 2"x4" NAILERS (2100f MSR SPF) SIDEWALL SEOTION $OMPH WIND LOAD PROTECTI LINER BASE TRIM ROW(S) 2"x8" SPLASHBOARD NOTE: CORNER AND ENDWALL COLUMNS TO HAVE 15" DIA. HOLES AND (2) 50# BAGS SACKRETE. ~--46M BASE ANCHORS ~ : ~(~) 50# BAGS SACKRETE PRE-MIXED W/WATER · " IN HOLE AND ALLOWED TO HARDEN. I;:.'L!:_~'f;':C:~l (2.) BO# BAGS SACKRETE PRE-MIXED W/WATER ,~ 2_O"~L! WHEN SETTING COLUMN. 2"x4" PURLIN 9" MESH-- 4"x16" BEAM (1350 FD) 2"×12" HEADER -- (NO. 1 S.Y.P.) 2"x6" BEV. F2 51M TRACK-- 3"x4" TR, ND. 1N"x2" BLOCK-- SR25 JAMB FLASHING 2"x3" JAMB (BEYOND) TRUSS HANGER W/(1) ½"x2~" M, BOLT & W/(14) 1~" R,S. NAILS 6" JAMB COLUMN BEYOND W/ADD'L 2"x&' LAMINATE FOR HEADER ~ SUPPORT SLIDING DOOR HEADER DETAIL I~LO"GRADE TO HEEL 7/16" OSB '2"x1-l/2"x4-5/8" FR. CLIP RAFTER FRAME ~2 ' 0" O.C. 2X6 PURLINS~2C~'' O.C, BLOCK t 2x6CNotSy~Xi.~2x4 SOFFIT SUPPORT HANGER '%'~-6" SOFFIT F/HI-RIB CAP -~HI-RIB STEEL -1/2"x5-1/2" M. BOLT & BEV. ~12" SOFFIT 2x6 HEADERS W/ 3x4x12" SPACEf BLOCKS & SR106 HDR FLASHING (4) 2Od R.S. NAILS FASCIA & SRgO NAILERS (2100 MSR SPE) -,,~SR39 COLUMN COVER ~IlO" BASE TRIM SPLASHBOARD 6'1-1/2" G' DIAMOND 'M~ PORCH BASE ANCHOR 6M ROD TRUSS SPACING 7L~] O.C. LIVE LOAD JO PSF DEAD LOAD ,~ PSF CEILIBG LOAD -- PSF TOTAL LOAD ,,.~4 PSF JOINT ~ I NAILS 4/~' ~x5 PL. JOINT $.B. £ JOINT L.C. .2 2xlO 4 JOINT PL. 16%10 PL. I~A. JOINT ..,~? ' J JOINT ~"6 JOINT -~5 /2[I JOINT RAFTER LENGTH TRDSS DESIGN SPECIFICATIOB: Truss has been designed by computer using the Purdue Plane Structures Analyzer IA~ current standards and specifications of recognized engineering principles. Output data will be provided 'upon request. LUMBER SPECIFICATION (1982 NOS for Wood Construction): l~er Chord -- 1-gsof - 1.SE mR Gouthern Pine Top Chord .... No. ] K.D. - 1~ Southern Pine Web Me~ers -~ No. 1 K.D. - 1S Gouthern Pine 42'L COMM. S.C. TRUSS TRUSS PLATE SPECIFICATION (IL'BO Evaluation Report MO. 2929): ' ASlil A-446, Grade A 20 Ga, and XB Ga,~ where ~oted, galvanized steel Morton truss plates identified by a j _h?a,on st~mped every 1-1_(4' .a?_~..tt~ c_e~.t.e_~___o..f_ ~h~_ pl__ate. _.