Loading...
HomeMy WebLinkAbout48060-Z �S�FFOt�-c Town of Southold � o�• 12/8/2022 y� P.O.Box 1179 0 V' z 53095 Main Rd A �ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43667 Date: 12/8/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 755 Middleton Rd., Greenport SCTM#: 473889 See/Block/Lot: 40.-5-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/9/2022 pursuant to which Building Permit No. 48060 dated 7/13/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Johnson,Craig&Jensen,Victoria of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48060 10/24/2022 PLUMBERS CERTIFICATION DATED 1 th riz d gnature z TOWN OF SOUTHOLD ay BUILDING DEPARTMENT y x ' TOWN CLERK'S OFFICE "o • SOUTHOLD, NY ~� z BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48060 Date: 7/13/2022 Permission is hereby granted to: Johnson, Craig 20 Middleton Rd Greenport, NY 11944 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 755 Middleton Rd., Greenport SCTM #473889 Sec/Block/Lot#40.-5-17 Pursuant to application dated 6/9/2022 and approved by the Building Inspector. To expire on 1/12/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00 Building Inspector pF SO�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlinCD-town.southold.ny.us Southold,NY 11971.-0959 QIGCOU�'w`� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Craig Johnson Address: 755 Middleton Rd aka 20 city:Greenport st: NY zip: 11944 Building Permit#: 48060 Section: 40 Block: 5 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SunRunSOlar License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 9.860kW Roof Mounted PV Solar Energy System w/29 340W Modules, DC Disconnect, AC Disconnect Notes: Solar Inspector Signature: Date: October 24, 2022 S.Devlin-Cert Electrical Compliance Form o�asfSoUly� -75S # # TOWN OF SOUTHOLD BUILDING DEPT. �0 • �o 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) / ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE i 2 • INSPECTOR L 500D ��pFSOUIyO 1 o �o # * TOWN OF SOUTHOLD BUILDING DEPT. IOU631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL So frAV-__ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: I t Y\61 11 Paid VIC,, 94'1*-, DATE Y W7, INSPECTOR .. .:... .•:M1;, e'9'J." ,432; I'. 7 ' t'f^t+': FIE 'D' PE 'TIO . L .INS P. T Nth'; :. L!, , . . .... . . . tv ....".: :;:.:;h 't FOUNDA'TTON:..iST +� X. ►. =:tit.<:;•x°'�:: :p�".�:', 1. _ ,� :•fJ•+,,, :.y .'+tom,. . k,i:� T1.I r,+;Y.'.''%,i, ,<t:;,'.',•,';"..,,.•r L�. %r'f.... , :'i; E. FO UND' l,;;t;;; A:'I' ON' Z I �. ND �• . .. . y.A`'1y`;�'`:{!1 A;+:..' '.'4:•..i}:.`::'i�''!L:,xA�•31.+y; .;.�,'.,:5:.y.:P':° ,rti ' :. Y •!. .. _ .. Y%., . .:.. ` . ,. ;•i:: '::.;.::.).;�` :1a t':ii'"�}+Li:: ;Fj1,b:3:' .. �5, .iai z f. 1' .,i v .. yi'' ..2 .d. ":1 . l U..i)'y.'P�'iyl ..u.:af1<:,..:.'`;:t:•.V•1•f�:�'�'i v'rd:' C`I 01,1 .r-kn,::f.•t.a.5 i';�'•i,l!1;•::; .',�.,l::!:'.`':.; . dA'> i.c�'-�.5�., ::z::'o: ks,; k i,,•;.;a 3'.vr: ,.4,vy.:.T m ::i.. . ..:.. r. ,' ROUGH FRAIYIII O ! . PLUIVI$'IN:G'. a.. ;..'�,,,: ,I�.;.rx;'.?.,.,...,, H ' ,YS,+:i,,.a,t+,,,:.?,.,i.`.. �...+1 .•r:.Y-�Y=,'.r: - .. 1.Y,.., ..5.1..,.E sn,..,k,.,�,,.>;.W Y, :<, �: i tv'. 'YJi••i', .1.. § a• 0 �.r ,a{•::r i.. ;el, r moi.:.: I :: . . . :.'. :: . ^}- 1 ,..,:;:s �j: „ :f ^,!k 1 •:f `',,1;:,+1.,1.: .,,I [�--- n•.. `°_, .r ty :: :':K ', :.•, INSUY�ATTp %N.p1Z N:, I Y.�. ::' ` `. p�7 ,; :w -' };; H. STATE EN' RGY'CO. iso>';_:; a-..: + :.:,<.� .:, .::. :,:: .t:;,:a I?F:' ro . x;m3'¢f: {,�'Si; '.ii'f'�%' 'SY,,:r•,,!,,,,if..,.. ,^.t':•f,!':%rl.,+ .R.�':,;•'';>f. ..t •. 1. . `[" :�:r.': :..!�'Ji" : ..C _, . •tG r. '? ' C . .y w,.. `Y; :t:,, ':tet C S 'r'i �,. - !~ u o k. ta;:.r:.:;:: Q . �' �^ .. :. D :•3 r. to 77 k:i'•i:.';{:r,. . i•V:. S.a..,-. . i. : ., *'-.*..: . ... . .. � . . . . t . :.:iiy,:�.::::; „ . : �� PA,0, [� ...'sS a. r: .4!. m v p 6 d ,.d — , 7 - '.... :: t: e : :::: h.. ::+::; ° ;: , . a : I. r}.t,..,. ,,.:..:. ':..`e!%n'.. ::-t...,. - :ti:id:t '�.a„i” .. . a�a•a % .:IH'l.'", .. ' fY �,. a'.' : ;.r:*:', ':i:is�;:••'' '':F., ,. ! :!;}:d�'+}i ins >Jt'i'i,!,u'.�:.+�:. r . . . . !,'', q. :. •'11``pi .d i.; :i j+.:•: :»'. f :�:.:', :tii11, ,"'` ,:L= if4'., {.. vt,...a. t4 f,I u(. 1 r::?., }..' tii 'Y,^'. :: ;r� + . H <fi....._ ';;.�a<;. per. .,,y' k) , X1.7'' .M1... s,,t(� '"'io r , . :,`.:tom .,c..:r',., ... ��4+... �iSif!liJ,i•:..'ii?!'.}.r iJl•a', . - ,.1. vi,.:1. M tl t'i'-,:'�',- ' 4— A � f. t... �. :t"; : , . . T. d\:'%.VYa7 .rY.y.4:.'*u e1t', .. , , o`p Pow•.-- TOWN-OF SOUTHOLD-BUILDING DEPARTMENT: - -- : Town,Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy.• o� Telephone (631) 765;1802 Fax(631) 765-9502 https://www.sotutholdtownny.gov . Date Received - APPLKATION FOR BUILDING--PERMIT For Office Use Only _R ® E C E ILII(/�R E . PERMIT:NO: . .. Building Inspector:. . . JUN 0 9 2022 `Applications and form s.:must be filled,out iri their entirety,,lncomplete BUILDING DEPT. applicaiions.will.not be accepted:.Where the Applicant is;reot-the_o'caner,an TOWN OF SOUTHOLD , ;Owner's'Authoriiation form(Pege:2)shall,be completed: Date: L OWNER($)OF PROPERTY: '. - Name: /�K -SCTM-#1000- . ��r �G - Project Address: /✓L _t' 67dLee �02! l�Cf7 .Phone#: Q) 7 _ � �.I _�_. . .. ::. :Email:, r m : ohne1A Ito MaiIingAdd.ress: -I G l �L CONTACT PERSON: Name: S �In V(/ . Cl. VVI S Mailing Address: lam] .�.:5 / Phone#: � b . Lo • 7 S-GEmail: .L 1 i'f'Y)l Un YU n C DESIGN PROFESSIONAL INFORMATION: Name:.Fz.S: "1vY CL .: ee VS - -6( l z� 1 e Y- r Mailing Address: Phone#: G� I (p,C SDI -±)Ci to 0_ Email: CONTRACTOR INFORMATION: Name: 1 Sin r, On l l�-h G� i�v us Mailing Address: .. Phone#: - Email: ` - Lo l�J - -7 �q t ' .trn l rten C DESCRIPTION OF PROPOSED CONSTRUCTION El New Structur ❑Addition ❑Alteration :❑Repair ❑Demolition Estimated Cost of Project: Will the lot 156 re-graded? ❑yes o Will excess:fill:be removed from:premises? ❑Yes tQ'o PROP TY INFORIVIATIO - R Existing use of property: :Intended use of property:. Zone or use district in which-pre rn- is-es is situated: Are there any:covenants and restrictions with respect to this property? ❑Yes o IF YES, PROVIDE-A:COPY. ❑:Check•.Iiox:After'Readlrt C°TFie:owner cdntractor desi n�`rofessional Is res onsible:•for.all draina'a andstorm.water:issues as rovided b`.•.::.� ., P P Chapter`,236 of the Town Code:•APPLICATION IS HEREBY MADE to the Building;gepartment'foft6eissuance of a eiiildidg Permit pursuant to the 8u11ding Zone_ Oidinance,of.the Town of Southold;Suffolk,County;New York and other applicable Laws,Ordinances or Regula4�ons for tFie'constnictiori of buiidings;. ' „additionsalte�ations or:for removal pr demolition:asherein described.The applicar%t agiees'to`comply,livRfi all applicable laws,ordinances;:buildingeode, housing code�and,regulations and to admit authorized inspectors ori premises,and in buildings)for necessary'inspections:False'statement§made herein are punishable,as a Class A rriisdemeanor'pursuarit to Section 210.45'of the iVew York State Pedal Law": Application 5ubmi ed By(print name): uthoriza:d Agent ❑O►wner S t V`� �►eV t Ill S .Signature of Applicant: Date: 20J ,?-, Z STATE OF NEW YORK) SS•.. . . .. COUNTY OF G�� G r� dt S�iYi being duly sworn, deposes and says that(s)he is the applicant (Name of indi dual signing contract)above named, (S)hee is the SAY.a I� 1�(/n S. . — �tJYI 1�y1'1 �J\�Q S Contractor,Agent, Corporate-Officer, etc: of said owner or owners, and=is-duly authorized to perform or have performed the said work and to make and file'this -_ .application;that all statements contained in.this application are true to the best of his/her knowledge and.belief;and that-the work will beperformedin the manner set forth in the.application file therewith. Sworn before.me this day of f�C :. :..20 av -77 a .. . . Not ry Public E COLE GIORGETTI .... ublic-State of New York o:01GI6292933 PROPERTY OWNER AUT HORIZATIOW fied in Suffolk County . ...... sion Expires Nov 12,,'2025 . (Where the applicant isnot the OWher)_ . , f koID residing at do hereby"authorize ... �'. . . to apply on- my-be h a I nmy-behaI o the Town of. otitliold Building Department for approval as described herein. Z ZoZ�. wner'S Signature' Date pi NICOLE-GIORGETDNer Notary Public State of .. ? NO.01Gl629293 ,Pri, 'OWner's Name.. -Qualified in Suffolk:c - my Commission-Expires No : - . Li BUILDING DEPARTMENT Electrical I cto TOWN OF SOUTHOLDUN O 9 2022 y _ Town Hall Annex- 54375 Main Road - POBr°oW�iroEPr o. Southold, New York 11971-0959 SoUTypLa s Telephone (631) 765-1802 - FAX (631):765-9502 rogerr(c-southoldtownny.gov seand(a)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (AII Information Required) Date: 2b. 12,2- Company Name: ccv)Cn V- CSC a . Electrician's Name: License No.: �. . ���� Elec. email: (�/' Yi'�l Sur ron �. Elec. Phone No: 51(v-(p/N- S-01 2 request an-email copy of Certificate'of Compliance Elec. Address.; 17� C(_f) a LC G,-29 S ILA-1 /l:Yq o JOB SITE INFORMATION (AII Information Required) - Name: Addr s: -. Cross Stre -: KA sm Phone No.: (� BIdg.Permit#: email: a h&)s6q F 5m�i Tax Map District: 1000 Section: a Block: Lot: :. . cG" BRIEF DESCRIPTION OF WORK, INCLUDE SQUA E FOOTAGE (Please Print Clearly): Falla 7M 6 Sd��r �u�Qls Square.:Footage: Circle All That Apply: Is job ready for inspection?:- YES �NO F]Rough In F-] Final Do you need a Temp Certificate?: : . YES 0 NO Issued On Temp Information: (All inforrnation required) Service Size❑1 PhF_13 Ph Size: A #Meters Old Meter#. . DNew Service0 Fire ReconnectOFlood_ ReconnectFlService ReconnectQUnderground❑Overhead #.Underground Laterals 1 2 H Frame Pole-Work done on Service? Y. N Additional Information: PAYMENT DUE WITH APPLICATION Putt 2P_c- � ��� LOT NUMBERS REFER TO "MAP OF FLEE7FIELD" FILED IN 7HE SUFFOLK COUNTY CLERKS OFFICE ON FEBRUARY 6, 1942 AS FILE NO. 1351. N SURVEY OF PROPERTY NEAR GREENPORT TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. x aw j' 1000-40-05-17 SCALE. 1=20' LOT 9 12'86, i MAY 27, 2010 Ln N 51w"- W ? _ .£ W N N-727 2O ass m aeGAPE FE . n I LF -.00 g LF. OX 23.9 LOT�O Tom' W""" 0.6y2.5, 7 o14NNEA0��_ O d Ij SW Z a 2a x WAS 1 ma ? 31.0• ~ } , 0 � Y jySc � 31.7 m QQy 7i � 11111MAY 24.3 ��� Q m 111�j O p�9 F OL P. p ti0 �Ifry a+r S8736'50"W 110.30' aeE ow OF PAWAII Cd . cERnFiED ro: IIJLMAM AVENUE CRAIG JOHNSON WCTORIA JENS£N FIDELITY NA77ONAL 777LE INSURANCE COMPANY ■=MONUMENT N.Y.S. LIC. NO. 49618 CHASE HOME FINANCE, LLC ANY At7ERA7101V OR ADDIDON TO THIS SURVEY IS A VIOLA77ON *ECON�ICUYORS. P.C. OF SEC77ON 7209OF 7HE NEW YORK STATE EDUCA77ON LAW. EXCEPT AS PER SEC77ON 7209—SUBDINSION 2.ALL CER77ROA77ONS (631) 765-5020 FAX(631) 765-1797 AREA=11 227 SQ. 1 R, HEREON ARE VALID FOR IH1S MAP AND COPIES 7HER£OF ONLY IF P:O. BOX 909 SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF 7HE SURVEYOR 1230 TRAVELER STREET WHOSE SIGNATURE APPEARS HEREON. SOUTHOLD, MY 11971 10-138 Wor NEw kers YORIc _ .: CERTIFICATE:OF: . . STATE Compensation Boar NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured:(use street address only) - 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc: (415)946-7500 225 Bush Street;Suite 1400 t I Registration San Francisco,CA.94104 1,c.NYS:Unemploymen Insurance...Employer Regis ra ion Number of Insured 507864264 Work Location.of.lnsured(Only required if coverage is specifically limited to' . ' ..... ' 1d.Federal Employer Identification:Number of Insured or Social Security certain locations.in New York State,Le.,a,Wrap-Up Policy) - - : . Number 77-0471407 as 2.Name and Address of Entity Requesting'Proof of Coverage: 3a:Name of Insurance Carrier (Entity Being Listed.as the Certificafe'Holder): AMERICAN ZURICH INSURANCE COMPANY Town of Southold : 3b.Policy Number of Entity Listed in Box"1 a" Town Hall Annex Building 54375 Route 25 .. WC 6142876-00. P O Box 1178 Southold,NY 11971.. . : : 3c.Policy'effective period-: : 10/01/2021: :: to 10/01/2022 3d.The Proprietor,Partners or Executive Officers are x ) included.:(Only check bo if all partners/officers included).... . I d. all excluded or certain.partners/officers excluded. This certifies that the insurance carrier:indicated above.in.box"3"insures the business referenced above in box"16"for workers' - compensation.under the New York State_Workers'Compensation Law.(To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workerscomen p nsation insurance policy). The Insurance Carrier or its licensed.agent will send .. this Certificate of Insurance to.the entity listed:ahove as the certificate holder in box"2". The insurance carrier must notify.the above certificate holder and the Workers':Compensation Board within 10 days IF a policy-is canceled due to nonpayment of premiums.or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage'indicated on this Certificate..(These notices may be:sent by regular mail:):Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its.liaensed agent,or uritil:the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information.only and confers no rights upon the certificate holder:This certificate.does hot amend,.. extend.or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond ihose:contained in the referenced policy. .::.. . This certificate'may be used as evidence.of a Workers'Compensation contract of insurance only while the underlying'policy is in effect. :Please Note: Upon cancellation of the workers'.compensation policy_indicated on this.form, if the business.continues to be -"named on a permit;license or contract issued 6y'a certificate holder,the.business must provide that certificate holder,with a new Certificate-of Workers'Compensation Coverage or other authorized proof that the business is,complying with the. mandatory coverage requirements of the New York State Workers'.Compensation Law. .. .., 'Under penalty of perjury,I certify that I am.:an"authorized representative or licensed.agent'of.the insurance carrier referenced .:..: . above and.that'the named insdred_has the coverage.as depicted on this form'..: Approyed by: Samantha Furlan. " = (Print name of authorized representative or licensed agent of insurance carrier) - APProved by: .::.: . �ayi :amu a� 09 ZZ ZD— .V b (Signature) :(Date) . .. ... .. .. ... Title: Underwriter . . :Telephone Number of authorized representative.or licensed agent of,ihsurance carrier: (415)53$-7125 .. Please Note:;Only insurance carriers and their licensed:agents are authorized to issue Form CA05.2.Insurance brokers are NOT authorized to issue it. .- -- ..... _ C-105.2 (9-17) :www.wcb.ny.gov SUNRIN0=02 TWANG ACORO° DATE(MMIDDIYYYY) CERTIFICATE OFLIABILITY 9i1072021' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY:AMEND, EXTEND. OR ALTER THE COVERAGE AFFORDED BY--THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT.BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR.PRODUCER;AND THE CERTIFICATE HOLDER. . IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the:pollcy(ies)must have-ADDITIONAL INSURED provisions or be endorsed: If SUBROGATION IS WAIVED; subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificatedoes not confer rights.to the certificate holder in lieuof such endorsement(s). CONTACT PRODUCER Walter .. .. NAME: Tanner - .. .. .. ... � - . � .. .. — - Alliant Insurance Services;Ind. PHONE FAX: ' 575 Market St Ste 3600 ac,No,Ext): - -. - . - : (AIC;No); San Francisco,CA 94105-- Et oREss:Walter.Tanner@alliant.com INSURERS AFFORDING COVERAGE NAIC# INSURER A::Navi ators Specialty Insurance Company 36656 INSURED INSURER B:Zurich American Insurance Company , 16535 " SUnrun Installation Services,Inc INSURER c:American Zurich Insurance-Cornpany 40142 775'Fiero Lane,Suite 200 Ph#805.540-7643 INSURER D San Luis Obispo,CA 93401 - .. INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISIOWNUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF..ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS .. . CERTIFICATE MAY BE ISSUED.OR MAY PERTAIN, THE'INSURANCE AFFORDED BY THE POLICIES:DESCRIBED HEREIN IS SUBJECT-TO ALL THE TERMS,:. .- EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS_. INSR --- ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER DD DD LIMITS A X COMMERCIAL GENERAL LIABILITY_, EACH OCCURRENCE $ .. :2'000'000 CLAIMS-MADE:F occuR LA21CGL2303211C 10/1/2021 1011/2022 1,000,000: DAMAGE TO RENTED PREMISES E currents $ MED FRCP(Anyone, erson $ 5,000 PERSONAL-&ADV INJURY $ . 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: " GENERAL AGGREGATE $.:... _29000,000 X POLICY FX PRO- LOC : PRODUCTS-COMP/OP AGG $ . 2,000,000 X OTHER:Retention:$100,000 •:.. _ Per Project Agg $ 10,0001000 BCOMBINED SINGLE LIMIT 2,000 000 AUTOMOBILE LIABILITY a accident) $ ' X ANYAUTOBAP614287700 " ' 10/1/2021 10/1/2022 BODILY INJURY Per. erson.. $ OWNED SCHEDULED AUTOS ONLY AUTOS :. BODILY INJURY Peraccident :$ HIRED NON-OWNED PROPERTY AMAGE: . AUTOS ONLY- AUTOS ONLY Pe 1ident $ Liability Ded.: $ . - . 250,000 X Cbpr�igo Ded,: X Call.:Not Covered ty UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE : AGGREGATE $ DED RETENTION$ $_. C WORKERS COMPENSATION "• X' PER AND EMPLOYERS'LIABILITY WC614287600 1071/2021 10/.1/2022. = 1'.000,000. Y/N E ANY PSTATUTE a R OPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT. $ .. . OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) 'E.L.DISEASE-EA EMPLOYEE $ 1,000,000 . If es,,scribe under y " - "' - _ _ "1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $- DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required):. Workers'Compensation Policy WC614287600 Deductible:$1,000,000... Evidence of insurance = CERTIFICATE HOLDER CANCELLATION .. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL "BE DELIVERED- IN ACCORDANCE WITH THE POLICY PROVISIONS. - .' . 53095 Route 25 Southold,NY 11971 - -' AUTHORIZEEDDRE(JPRESENTATIVE - ACORD 25(2016/03) - "' ©1988-2015 ACORD CORPORATION. All_rights reserved. The ACORD name and loco are reaistered marks of ACORD Hew. worke'r's' . CERTIFICATE.;OF INSURANCE.COVERAGE: :.. . ATE' .COfTIp2rlSatlOrl .: . Board DISABILITYAND PAID-FAMILY LEAVE BENEFITS LAW PART 1:To-be completed by Disability and Paid Family:Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured:(use street address only):.: 1b.Business Telephone Number of Insured:' . Sunrun Installation Services Inc. 845 268-2595 - 29th Floor San Francisco, CA 94105:'. l e.Federal Employer.ldentification Nuihberof lnsured WorkLoeabonofInsured(Onlyrequiredifcoverageisspecificallylimitedtocertain ... ... or.SocialSecurityNumber, locations in New York State,I.e.,.Wrap-Up Policy) 77-0471407 2.Name and Address of Entity Re uestin Proof of Coverage -- - 3a.Name of Insurance Carrier _. - ty q 9 9 - i (Entity Being Listed as the Certificate;Holder) ... - The Prudential Insurance CompanyIca Town of Southold --- 3ti.Policy Number of Entity Listed:in Box"la" 54375 Route 75 CG-52830-NY P.0.=Box 1179 Southold, NY 11971 3c.Policy effective period 01/01/2022 to 12/31/2022, 4. Policy:proviides the following benefits:: 0 A.Both disabilityand paid family leave benefits. - ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family'Leave Benefits Law. ❑ B.Only the following class or classes bf employer's employees: Under penalty of perjury,1 certify that I am an authorized,'representative or licensed agent of the insurance carrier referenced above and_thatthe named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date SignedJanuary 19,202. . . By -Signaa`tu'reofins'u�ancecarner'saut oiizedrepresentativeorNYSLicensedlnsuranceAgentofthatinsurancecarrier) (215)784-2883 vice President,Contracts Tele hone Number Name and.Title .. IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized'representative or NYS; . Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or.5B is checked,this certificate is NOT COMPLETE for purposes of Section-220,Subd.8'6f the NYS.. = --- Disability and-Paid-Family Leave Benefits-Law. It must be mailed for:completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton, NY"13902-5200. -_- PART 2.To be completed by the NYS,Workers'Compensation Board(Only if sox 4C or 5B of Part i has been checked) State of New York... . ..... :...: Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above=named employer has complied with the NYS Disability and paid Family Leave Benefits Law with respect to all of his/her employees.: .. : Date Signed .By . (Signature of Authorized NYS'Workers'Compensation Board Employee). Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS.disability and paid family leave benefits insurance policies'and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.:Insurance brokers are NOT authorized to issue this form.: 'I IIp D13420.1 (10-17) III��I�IIIIIIIIIII I0IIIDIIII(IIIIIIIIIIIIII�III1II1 sunrun .... ---- --- . .. ....... . . . .. .. . .. . .. NY-TOWN SOUTHOLD— : Building Department . .. . . . [craig Johnson] . . 20:Middleton Rd, Greenport; NY, 11944. . The following revisions have been r-hhad the plans: : ::.. 1. Addling.a 60A unfused AC disco and_switching to JA 335A due to shortage offlie JA340s.--- Response:.Error acknowledge:and data provided::. .... . .... Thank you for your time, .. -Anil Mehta . ... . . . : ::.. PV System.Designer a . Sunrun q.q. q mw a . . CT J 19 �- ... .. .. . v . : z a Astra .1_.720 September 25,,2022... .. . CAT 4 ... ....... P . Subject:Structural Certification.for.Proposed Residential Solar.Installation. .. .. ENGINEERS_. ... .. . . . . ... . Job-Number:216R-020JOHN;Rev:B:. Client:craig Johnson, I� Address:20 Middleton Rd,Greenport,NY'11944.. P \ OC:T' 11 ?119? I Attn`.To Whom It.May Concern iL® Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site obseryations and the design criteria-listed below. .. ' ' Design Criteria: A.2020 NEW YORK STATE RESIDENTIAL CODE WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS " -.Basic Wind Speed V=.128.mph;Exposure B . Ground Snow.Load=25 psf . Based on this evaluation;I certify that the alteration to the existing structure by the installation of.the PV system meets the requirements of the :applicable existing andlor new building code provisions:referenced above. • . ... . .Additionally,I certify that the PV:module assembly including all attachments supporting it have'been reviewed to bean accordance with the. manufacturers specs ications. . ..... . ..... . ..... . ..... . .. ... ... . Results Summary Hardware Check Includes Uplift Check on Attachments/Fastener,.StructUre:ChecKConsiders Main Stricture ' Orientation Attachment Spacing/Cantilever Configuration Max OCR Result .. .. Landscape .. .. .. o' 64'%25 Staggered 52/o. Pass ... ... ... .. AR-01 ... . . ... .. ' Portrait 48/24 : Staggered_. ° . : 62/o Pass- Roofing:Material Pitch. . „S.tructure:Check Comp Shingle r 30.° I. . 'Pass Orientation Attachment Spacing/Cantilever Configuration Max!)CR Result . 52%. P2SS, - Landscape ' 64/25 Staggered ... ... ... _. AR-02 .. Portrait 48/24 : Staggered : 62% Pass .Roofing,Material ::; Pitch::; 'Structure Check .. _. ... .. Comp Shingle- _. .. .. ..30° I Pass q. - - - .. °,A .. ... ... .. ... .-. ... .. ... ... -. .. .. .. 191�u xcp :. - - - c� _.. _.. . 09131i522��. FESSIO Paul Zacher,P.E: . . . 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 I P- (916)961-3960 Professional Engineer T: 916.961:3960 x101 -- - ... .. .. E-mail:pawl@pzse.com SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:9715W DC,7600W AC •ALL WORK SHALL COMPLY WITH 2020 NEW YORK STATE RESIDENTIAL CODE SOLAR MODULES •MODULES:(29)JA SOLAR:JAM60S10-335/MR WITH 20181RC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS SE SERVICE ENTRANCE PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE760011-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, MP MAIN PANEL PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLYSP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT _ B •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ® CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703, Q ATTIC VENT .:of NEw •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT K,Zq VO � MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT C,y�P,p� •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT C CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AIC SATELLITE DISH FESSIONP AC DISCONNECT(S) p P�1365� RO •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC For Structural Only O DC DISCONNECT(S) FIRE SETBACKS •10.38 AMPS MODULE SHORT CIRCUIT CURRENT. F--, 16.21 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(D)]. CB IQ COMBINER BOX HARDSCAPE F 7 INTERIOR EQUIPMENT -PL- PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER IAZIMUTH VICINITY MAP COMP COMPOSITIONMPOSITION DC DIRECT CURRENT 00825-ME (E) EXISTING H—LE HYn 1 ESS ENERGY STORAGE SYSTEM W.= EXT EXTERIOR - - �/'m INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC CRAIG JOHNSON 25 MSP MAIN SERVICE PANEL 20 MIDDLETON RD, (N) NEW GREENPORT,NY,11944 / NTS NOT TO SCALE o OC ON CENTER TEL.(401)578-8818 PRE-FAB PRE-FABRICATED APN: PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC PROJECT NUM Rod, RSD RAPID SHUTDOWN DEVICE dd,Greenport,NY... t TYP TJOHN TL YPICAL DESIGNER: (415)580-6920 ax3 V VOLTS CHRISTOPHER LUKE W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET 8 PATTY MCL 8/10/2022 MODULES SWITCHED REV:B 8/10/2022 C PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1116"=V.0. PITCH AZIM AZIM (SOFT) ® AR-01 30° 240° 252° 253.5 AR-02 30° 60° 72° 271.6 (E)DETACHED STRUCTURE ROOF PATHWAYS IT TYP) INV SMP SE GROUND ACCESS POINT B ° e° c (E)RESIDENCE (N)ARRAY AR-02 (E)GATE r s u n r u n 00825-ME ROOF PATHWAYS ° ° ° P eWW.Wi�n�wue wr iiroi (3-TYP) FIRE SETBACKS F—e.exe.m (18"TYP) ° GROUND CUSTOMER RESIDENCE: CRAIG JOHNSON ACCESS POINT (N)ARRAY AR-01 20 EENPO T,N Y,1 GREENPORT,NY,11944 TEL.(401)578-8818 APN: RO OF NE(-yy PROJECT NUMBER: �Ot> Y.Z'1 Cy Op 216R-020JOHN 0\00-� DESIGNER: (415)580-6920 ex3 X CHRISTOPHER LUKE 1SS10 SHEET SITE PLAN For Structural Only REV:B 8/10/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC DetailMax Landscape Max Landscape Max Portrait Max Portrait MAX Configuration SNOW LOAD:25 DISTRIBUTED LOAD.,3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang WIND SPEED: AR-01 COMP SHINGLE-RLU 1Story 2X6 RAFTERS 11'-3" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 51-4" 7-1" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 1 Story 2X6 RAFTERS 11-3" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2--l" 4'-0" 2'-0" STAGGERED STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY 01-AR-01-SCALE:118"=1'-0" ENGINEER OF ANY POTENTIA AZIM:240" STRUCTURAL ISSUES PITCH:30• OBSERVED PRIOR TO 6" 6" PROCEEDING W/ 22'4" _ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE JT' EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANREDUCED WITHIN THE 12" 5'4' P _ - 5'-4"TYP. - BOUNDARY REGION ONLY AS FOLLOWS: ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"-V-0- AZIM. s u n r u n PITCH::330" 0 B 00825-ME 6" V-11 — . 11.1 cac wxe mre CUSTOMER RESIDENCE: CRAIG JOHNSON 20 MIDDLETON RD, I GREENPORT,NY,11944 - 5'-4'7YP. - I TEL.(401)578-8818 6'_7" APN: OF NElyL PROJECT NUMBER: ❑ I K.�4Cy�0.p 216R-020JOHN co P� ❑ 2'$ t DESIGNER: (415)5806920ex3 CHRISTOPHER LUKE o1ssil SHEET LAYOUT fESSION REV:B 8/102022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: NOTE:TOTAL PV BACKFEED=40A M CENTRAL HUDSON USED FOR INTERCONNECTION UTILITY 98428028 CALCULATIONS ACCOUNT#: GRID 9673009103 EXISTING 200A MAIN BREAKER SOLAREDGETECHNOLOGIES: SE760OH-US WITH REVENUE EXISTING GRADE METERING(PN 200A SE760OH-USS3),7600 WATT MAIN INVERTER FACILITY PANEL 7600 WATT INVERTER 2 JUNCTION BOX 1 PV MODULES LOADS �, OR EQUIVALENT JA SOLAR:JAM60SIO-335/MR A ! (29)MODULES °° OPTIMIZERS WIRED IN: p ES OF(15)OPTIMIZERS GFPD (t)SERIES OF(14)OPTIMIZERS B (N)40A o"w°o�, LOAD RATED DC DISCONNECT PV BREAKER AT WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END COMPLIANT P401 OF BUSBAR CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND t NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 2 1"PVC OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 1"PVC OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 00825-ME 15CHARLOTTEAVE H-k-1-1 111801 PHONE 805510 5181 AX 81518810!1 CUSTOMER RESIDENCE: B CRAIG JOHNSON 20 MIDDLETON RD, GREENPORT,NY,11944 to CTERISTICS 0S10-33 335 W VOLTAGE: 41.32 V P370 OPTIMIZER CHARACTERISTICS: TEL.(401)578-8818 LTAGE: 34.48 V MIN INPUT VOLTAGE: 8VDCAPN: CURRENT: 10.38A MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX INPUT ISC: 11 ADC 216R-020JOHN MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580E920 ax3 SYSTEM CHARACTERISTICS-INVERTER 1 CHRISTOPHER LUKE SYSTEM SIZE: 9715 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 15V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:B 8/10/2022 SYSTEM OPERATING CURRENT: 24.29 A SYSTEM SHORT CIRCUIT CURRENT: 30A PAGE PV-4.0 WARNING ARNING INVERTERI NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. COMBINER PANELMAXIMUM SYSTEM • ,• 480 1 •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN 30 • •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR HARING LABEL LOCATION: •• • METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). • •• •'1 • • • • 15 • INVOLVED. • LABEL LOCATION: PER CODE(S):CEC 2019:705.12(B)(2H3Hc), SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), NEC 2017:705.12(8)(2x3xc) LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):CEC 2019:690.13(B).NEC PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 2017:690.13(8) WAR 7AND POWER SUPPLY POWER SOURCE OUTPUTCONNECT10N ES:UTILITY GRID DO NOT RELOCATE THIS SOLAR ELECTRICOVERCURRENT DEVICESYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(Bx3),NEC 705.12(B)(2x3)(b),NEC 2017: 2017:705.12(B)(3) ^ 705.12(Bx2x3)(b) B ■�' �• BUILDING SUPPLIED BY UTILITY •• SOLAR PV SYSTEM GRID AND PHOTOVOLTAIC SYSTEM LABEL LOCATION:INSTALLED WITHIN 3OF RAPID SHUT DOWN SVUTCH PER CODE(S):CEC 2019:690.56(C)(3 ),NEC s u n r u n 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018: 4 _ 12005.3,CFC 2019:1204,5.3 SOLAR PV SYSTEM EQUIPPED 00825-ME WITH RAPID SHUTDOWN 15-0—E 3MICNSV4LE NY 11!01 • • • � PN�NE���, ■• ■ • ■ CUSTOMER RESIDENCE: CRAIG JOHNSON LABEL LOCATION: 20 MIDDLETON RD, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, GREENPORT,NY,11944 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3 TURN RAPID SHUTDOWN PV SYSTEM ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF" DISCONNECT TEL.(401)578$818 PER 2017.69:CEC(3),6 0.31((G)(3),690.31)(4)I (G)(4), POSITION TO SHUT DOWN NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: APN: 605.11.1.4 PV SYSTEM AND REDUCE SHOCK HAZARD IN THELABEL LocnnoN: PROJECT NUMBER: ARRAY. POINT OF INTERCONNECTION 216R-020JOHN PHOTOVOLTAIC ADISCONNECT (PER CODE:NEC690.56(B),NEC705.10,225 37,230.2(E)) OPERATINGMAXIMUM AC DESIGNER: (415)580.6920 ex3 NOMINALOPERATING AC VOLTAGE: CHRISTOPHER LUKE LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690.54,NEC 2017 690.54 ARE CONNECTED. PER CODE(S):CEC 2019:690 56(C)(1)(.),NEC 2017: REV:B 8/10/2022 690.56(Cx1)(a) PAGE PV-5A Harvest the Sunshine *"��•.�,.1 tL1i3.o��p.!�►�ui�i.�•a••a•�ia•aa+�� Jaataaa ..�.+;ij-�+ 1�i�'1►iw��o�'+M�?;i1\�i�1�a�+z.�\\1\1\�.���a\�aa�je`Ca`t������?2,�� 340W MBB Half-Cell Module JAM60S 10 Mono / Series (introduction] Assembled with mu6busbar PERC cells,the half-cell configuration of the modules offers the advantages of . power output, better temperature-dependent shading effect on the energy generation,lower risk of hot spot,as well as enhanced tolerance for mechanical loading. Higher output power Lower LCOE Less shading and lower resistive loss Better mechanical loading tolerance Superior warranty,I Comprehensive Certificates \i • 12-year product warranty IEC 61215,IEC 61730, UL 61215,UL 61730 • 25-year linear power output warranty ISO 9001:2015 Quality management systems 00 ISO 14001:2015 Environmental management systems • OHSAS 18001:2007 Occupational health and safety manage- ment systems ® IEC TS 62941:2016 Terrestrial photovoltaic(PV)modules— ;. R� Guidelines for increased confidence in PV module design JA Linear Power Warranty ■ Industry Warranty JASR• • www.jasolar.com •• JASOLAR JAM60S 10 320-340/M R MECHANICAL DIAGRAMS SPECIFICATIONS 996`1 3s.+ Cell Mono It Weight 18.7kgt3% Dimensions 1689t2mmx996t2mmx35t1mm Enlarge view of mounting hoW 01) Cable Cross Section Size 41rrim" (12AWG) Grountlirg hobs °°aLe4 No.of cells 120(6x20) O o O oon:.mm Junction Box IP68,3 diodes reolr�ng hob• Connector QC 4.10 (1000V) e vl•�e• QC 4.10-35 (1500V) N111111Cable Length 9 Portrait:300mm(+)/400mm(-); D,-,nvholes El (Including Connector) Landscape:1000mm(+)/1000mm(-) a vw<ee Packaging Configuration 30 Per Pallet Remarkcustomized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 -320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[W] 320 325 330 335 340 Open Circuit Voltage(Voc)[V] 40.60 40.87 41.08 41.32 41.55 Maximum Power Voftage(Vmp)[V] 33.73 33.97 34.24 34.48 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_lsc) +0.044%/°C Temperature Coefficient of Voc(P_Voc) -0.272%/°C Temperature Coefficient of Pmax(y_Pmp) -0.350%/`C STC Irradiance 1000W/m', cell temperature 25'C,AM1.5G Remark.Electrical data in this catalog do not refer to a single module and they are not part of the offer They only serve for comparison among different module types ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 320/MR -325/MR -330/MR -335/MR -340/MR Maximum System Voltage 1000V/1500V DC(UL) Rated Max Power(Pmax)[VJJ 241 245 249 253 257 Operating Temperature -40°C-+85°C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)M 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 Ib/ft') Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±2C NOCT Irradiance 800W/m2,ambient temperature 20°C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 1000W/rn= 1000W 10 10"L 300 -!lUUW/nY -600W/m' 25°C a aUm s 250 -400W/m 6 -40°C UW/ 6 600W/m: S 200 - 200W/n? 6 70°C 3 150 Q 4 400W/m' d tj 4 100 2 50 2 0 0 10 20 30 40 00 10 20 30 40 0 0 10 A 3D 4D voltage(v) Voltage(V) Voltage(V) ModulesPremium Cells, Premium solar=@9 z • Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/SE5000H-US/ SE6000H-US/ SE7600H-US/SE1000OH-US/SE1140OH-US solar [' `„HD e solar,3? z 225': Wa •t0• _.a4, O 0010 _.r O e o 0 � I � e - O O Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring IIIIIIIIIII1,D Outdoor and indoor installation wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us solar ' • • z Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/ SE1O00OH-US/ SE1140OH-US SE3000H-US SE380OH-US SE5000H-US SE6000H-US I SE760OH-US SE1000OH-US SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA .............................................. ................ 3300,E 208V. ................ .5000.@.208V ................ ................. ................. ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,E 208V. ................ .5000.@.208V- ................ ................. ................. ........... AC Output Voltage Min.-Nom:Max. ( - ✓ Vac X183;208.229)........................... ............... ................ ................ . AC Output Voltage Min.-Nom.-Max. .......... ................ ................. ................. ........... .1..211-;� .:�4)........................... .......✓ ✓ ✓ ✓ ✓ ✓ Vac ......... ................ ................ ................. ................ ................. ........... ..... ........... AC Frequen (Nominal) 59.3-60-60.5111 Hz Maximum Continuous Output Current 16 24 A 208V ... ................ ................ ................ ................. ................ ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..C°?240V.................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold 1 A .................................... ........................................................... .......................................................... . Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W ........ ............................ . ...... ................ ................. ......765...... ........... Maximum DC Power @208V 5100 7750 ..................ower...................... ................ ................ ................ ................. ................ . ................ ................. ........... Transformer-less,Ungrounded............ .............................................................Yes........................................................... ........... MaximumInput Voltage 480 Vdc .................................................................... .................................................... Nominal DC Input Voltage 380 400 Vdc .. ................ ................. ................. ........... Maximum Input Current 208V 9 13.5 Maximum Input Current @240V 8.5 10:5 13:5 16S 20 27 30.5 Adc ........... ................ . . Max. pShortA .........In..ut..........Circuit............Current............. ...........................................................45.............................................................. .......dc.... Reverse-Polarity Protection Yes ......................... . ............................................................ ........... Ground-Fault Isolation Detection600ko Sensitivity MaximuminverterE.Tciency............. ...•.•99..•.... . ........ 992 °6 CEC Wei&hted ETT;iencY................... ...........................................................99 % ........................................................... ........... Nighttime Power Consum tion <2.5 W ADDITIONAL FEATURES Supported Communication In R5485,Ethernet,ZigBee(optional),Cellular(optional) RevenueGr...... tp.....ANSI C12.20........ .......................................................Optional!.. ...................................................... ........... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA 022.2,Canadian AFCI according to T..1:1- M-07 ................ ...... ... .... . ... ..... Grid Connection Standards IEEE 1547,Rule 21,Rule 14(HI) ............... ......................................................................... ............................................... ........... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/A of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWG RanB?................................ . 146 AWG .................................................................................... ............ ............ ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm x 185 .............................................. .......I......................... -...........--.. .................................. .............-..................... ........... Weight with Safety Switch 22/10 I 251/11:4 I 26.2/11.9 <511.9 38.8/17 6 Ib/kg Noise •• . <25 0 deA .......... ......................................... Cooling Natural Convection Natural convection Operating Temperature!4W............ -13 to+140/ 25 to+6d �40'F/ 40'Coptlon) F/'C ................. Protection Rating NEMA 3R(Inverter with Safety Switch) For other regional settings please contact SolarEdge support Ill Revenue grade inverter P/N:SEn nH-USOOONNQ 131 For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 161-40 version P/N:SExroaH-USOOONN1.14 ROWS e OPTIMIZED are trademarks or registered trademarks'D '• 7 I,_ rack- Solar . RL • 1w� Installin • Solar Has Never Been This Fast & Easxr ,` System designed with ��� All parts fit in a box for easy ` maximum versatility for any � logistics arrays including staggered Drop-in features make the - � install process intuitive and fast 0 Simple design allows system to ���� be installed by single installer U Listed to UL Standard 2703 for on the roof � Grounding/Bonding and Fire Classification SnapNrack RL Universal is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount • basic components highestincredible flexibility with a single Universal mounts that fit module heights from 32 - 40 mm and the •. of Flash Track with Patented Umbrella Technology • Single Umbrella lag screw secures flashing and flash track to roof in one complete action • Umbrella technology provides weatherproofing with a long- lasting mechanical seal • Flash track is designed for maximum versatility with 6 inches of North-South adjustability for all Mounts Mounts • Single mount used at all locations on array • Extreme time saver by eliminating link interference through the flexibility of the Mount to change orientation • Features a rock-in channel nut design for easy attachment to Flash Track • Slotted riser provides leveling for easy height adjustments ifo Links • Simple design provides mounting platform between two to four modules • Clamps onto top of modules securing them in place while providing row-to-row bonding 1� • Next row of modules easily slides into place as with the Mounts Skirt • Easily locks to bottom of module mounts and links for clean aesthetics • Ensures a strong structure for leveling and alignment of first row of modules • Skirt length is compatible with both portrait and landscape module orientations Quality. Innovative . Superior. SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve • • quality and . • www.snapnrack.com contact a snapnrack.com Solar • • Solutions. DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins 5flueNruck- REVISION- Solar Moing Solutions PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 94105 USA PHONE(415)560-6900.FAX(015)560-6902 242-02155 1NE iNFOR MN W r OS wAwmo s casco IS P ua ITIM W rMY.un REPRODUCTION,DISCLOSURE.OR USE SUNRUF IS PROM&TED VIiTgUt rHE WRITTEN CONSBlT OF SIMRUN SOUTH LLC. 10 5 0 e 4 3 8 1 2 o 6 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK, RL UNIVERSAL, LEVELER, MILL 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL 4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK 5 1 SNAPNRACK, RL UNIVERSAL, BONDING CLIP 6 1 SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS 8 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1IN, SS 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 10 1 BOLT, FLANGE, SERRATED, 3/8IN-16 X 2-3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 623 UP, 674 DOWN, 505 SIDE ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.73 DESCRIPTION: DRAWN BY: SNAPNRACK, RL UNIVERSAL, MOUNT mwatkins -SnapWach REVISION: Solar Mountmq Solutions PART NUMBER(S): A 595 MARKET STREET,29TH FLOOR SAN FRANCISCO,CA 96105 USA PHONE(415)590-6900 FAX(415)580-6902 242-02155 -EMFORMATgNIN HIS OiUW NG bLONPIpEN KNpPROPPoETMY ANY REPRODUCTION.DISCLOSURE,OR USE THEREOF M PROM&TED W—UT THE WRITTEN CONSENT OF S NWN SOUTH LLC. 1.50 3.41 1.50 r; 2.35 1.50 1.55 .66 2.00 1.24 1.00 SLOT 2.63 ALL DIMENSIONS IN INCHES A1710 ED AS NOTED DATE: v� .P.# FEE: BY: NOTIFY BUILDING CEPARTME AT 765-1802 8 AM TO 4 FM FOR THE FOLLOWING INSPECT IONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRANVNIG & PLUMBING S. INSULATION 4. FINAL - CONSTRU! ION MUST BE COMPL-c"'E F-0.1' ".0. ALL CONSTRU lrJN HALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. �.iscbnnrC� COMPLY WITH ALL CODES OF 6CQ`�4 NEW YORK. STATE & TOWN CODES 4e AS REQUIPED AND k-ONDI , '.ONS OF �HOLDTrWNZF 1'CQdt'I ACCeS.fI�LQ ��! NOI 1tTOti"d l ANNIN BOAF�D S� 'T TEES r ll, OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA T OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED March 29,2022 Astra v.1.65 PZECAT COA Subject:Structural Certification for Proposed Residential Solar Installation. Mr Job Number:216R-020JOHN;Rev A Client:craig johnson Address:20 Middleton Rd,Greenport,NY, 11944 D " E DAttn:To Whom It May Concern JUN 0 9 2022 A field observation of the existing structure at the address indicated above was performed by a W -Lu run.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 2020 NYS CODE BOOKS WITH 2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V=128 mph,Exposure B •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally,I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary(Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure) Orientation Attachment Spacing/Cantilever Configuration GoDCRng Result Landscape 64/25 Staggered 43% Pass AR-01 Portrait 48/24 Staggered 52% Pass Roofing Material Pitch Structure Check Comp Shingle 30° Pass Orientation Attachment Spacing/Cantilever Configuration GoverniDCRng Result Landscape 64125 Staggered 43% Pass AR-02 Portrait 48/24 Staggered 52`'<, Pass Roofing Material Pitch Structure Check Comp Shingle 30• Pass OF NEW K. Zq C y0 COLU L x091365- ��•� AR�FESS1 Paul Zacher,P.E. Professional Engineer 1478 Stone Point Dr.Suite 190,Roseville,CA,95661 P (916)961-3960 T: 916.961.3960 x101 E-mail:paul@pzse.com SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SYSTEM SIZE:986OW DC,760OW AC •ALL WORK SHALL COMPLY WITH 2020 2020 NYS CODE BOOKS WITH 2018 SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(29)JA SOLAR:JAM60S10-340/MR IRC/IBC/IEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND SE SERVICE ENTRANCE •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN SE7600H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-0.0 ELECTRICAL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. Q ATTIC VENT OF NEpy •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT K.ZA y0 MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT co •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT AC DISCONNECT(S) meq.091365-( •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). Al� Q SATELLITE DISH ROFESSIONP •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC ® For Structural Only O DC DISCONNECT(S) FIRE SETBACKS •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.6(b)). CB IQ COMBINER BOX HARDSCAPE F_7 INTERIOR EQUIPMENT —PL— PROPERTY LINE J J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 00825-ME DC DIRECT CURRENT (E) EXISTING uawaiorrewe.Hxxm�er nroi ESS ENERGY STORAGE SYSTEM r�xea EXTERIOR " NTT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC CRAIG JOHNSON 25 MSP MAIN SERVICE PANEL 20 MIDDLETON RD, (N) NEW GREENPORT,NY,11944 ♦ �/ NTS NOT TO SCALE \ OC ON CENTER TEL.(401)578-8818 ORI pd,7r PRE-FAB PRE-FABRICATED APNPSF POUNDS PER SQUARE FOOTPV PHOTOVOLTAIC PROJECT NUMBER: ddletonRSD RAPID SHUTDOWN DEVICETL 216R-020JOHN eenpor NY... t TYP TYPICAL DESIGNER: (415)5801i920ex3 0 V VOLTS CHRISTOPHER LUKE W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET �d,29 REV:A 3/262022 a PAGE PV-1.0 ARRAY TRUE I MAG I PV AREA SITEPLAN-SCALE=1116"=1'-0" PITCH AZIM AZIM (SQFT) ® AR-01 1 30' 1 240° 252° 1 253.5 AR-02 1 30° 1 60' 1 72° 271.6 (E)DETACHED STRUCTURE ROOF PATHWAYS (3'n'P) INV rMID SE GROUND ACCESS POINT e (E)RESIDENCE (N)ARRAY AR-02 (E)GATE ° a IFa 9 s u n r u n a ° 00825-ME aROOF PATHWAYS a E .HrxsvL�NYtlmt (3-TYP) FIRE SETBACKS (18 TYP) CUSTOMER RESIDENCE: GROUND CRAIG JOHNSON ACCESS POINT (N)ARRAY AR-01 20 EENPO T,N Y,1 GREENPORT,NY,11944 TEL.(401)578.8818 APN: OF NE(1,Y PROJECT NUMBER: RID 0O���Ot� K Z40 0P� 216R-020JOHN 0DESIGNER: (415)5806920 w(3 W CHRISTOPHER LUKE Polo ��F�� SHEET °Rp SS(ONP� SITE PLAN For Structural Only REV:A 3i2MO22 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-3" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 128 MPH 3-SEC GUST. S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON5/16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-3" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2--l" 4'-0" 2'-0" STAGGERED STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/8"=V-0" ENGINEER OF ANY POTENTIA AZIM:240° STRUCTURAL ISSUES PITCH:30° OBSERVED PRIOR TO 6" 6" PROCEEDING W/ - 16'-9" —6'-0"— 22'4" - INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE 1'-0" EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHAN g•_7" REDUCED WITHIN THE 12" - TYP - - 5'4"TYP. - I BOUNDARY REGION ONLY AS FOLLOWS: 1 ••ALLOWABLE ATTACHMENT SPACING INDICATED ON 1 PLANS TO BE REDUCED BY 2'-1 7" 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/8"=1'-0" AZIM.60° s u n r u n PITCH:30° 00825-ME 6" 16'-10" 11'-2" 11'-3" —6-11"—} vemsnAVE,"—LEmiiroi va easxe pzx 1,�„ CUSTOMER RESIDENCE: CRAIG JOHNSON Ll 3,4„ 20 MIDDLETON RD, GREENPORT,NY,11944 5'-0"TYP. - TEL.(401)578-8818 19 ag•_7'• APN: OF NPROJECT NUMBER: ❑ I �,K.ZA Cy O,p 216R-020JOHN ❑ 2-8 * DESIGNER: (415)580b920 ex3 CHRISTOPHER LUKE z �gR�91365- F.` SHEET LAYOUT FESSIO REV:A 3/26/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120240 VAC SINGLE PHASE SERVICE O METER M NOTE:TOTAL PV BACKFEED=40A M CENTRAL HUDSON USED FOR INTERCONNECTION UTILITY 98428028 CALCULATIONS ACCOUNT#: GRID 9673009103 EXISTING 200A MAIN BREAKER SOLAREDGE TECHNOLOGIES: SE760OH-US WITH REVENUE EXISTING GRADE METERING(PN 200A SE7600H-USS3),7600 WATT MAIN INVERTER FACILITY PANEL 7600 WATT INVERTER2 JUNCTION BOX 1 PV MODULES LOADS s OR EQUIVALENT JA SOLAR:JAM60S10340/MR ! (29)MODULES DC �j!/ OPTIMIZERS WIRED IN 0 : Y' (1)SERIES OF(15)OPTIMIZERS GRWM GFPD (1)SERIES OF(14)OPTIMIZERS •aLm (N)40A LOAD RATED DC DISCONNECT PV BREAKER AT WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END COMPLIANT P370 OF BUSBAR CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER 2 1"PVC OR EQUIV. (4)10 AWG THHNITHWN-2 NONE (1)10 AWG THHNITHWN-2 s u n r u n 3 1"PVC OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 00825-ME 15CHPR07 AVE,HICNBVILLENY 11801 PHONE 005.5q 5N] FrVt 84.88 XR3 CUSTOMER RESIDENCE: CRAIG JOHNSON 20 MIDDLETON RD, GREENPORT,NY,11944 MODULE CHARACTERISTICS JA SOLAR:JAM60S10-340/MR: 340 W TEL.(401)578-8818 P370 OPTIMIZER CHARACTERISTICS: OPEN CIRCUIT VOLTAGE: 41.55 V APN: MAX POWER VOLTAGE: 34.73 V MIN INPUT VOLTAGE: 8 VDC SHORT CIRCUIT CURRENT: 10.46 A MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX INPUT ISC: 11 ADC 216R-020JOHN MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580b920 ex3 CHRISTOPHER LUKE SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 9860 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 15V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 3/26/2022 SYSTEM OPERATING CURRENT: 24.65 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 OWARNINGSIGNS AAND SPECIFICATIONS ! ARNING INVERTER NOTES •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE PHOTOVOLTAIC SYSTEMPHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. COMBINER PANEL VOLTAGE:MUM SYSTEM 480 • .SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS WORDS,COLORS AND SYMBOLS. r 30 •• •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION: •• OF THE OPEN POSITION •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PHOTOVOLTAIC AC COMBINER(IF • -• •• •• • 15 •• INVOLVED. APPLICABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: PER CODE(S)::CEC 2019:705.12(B)(2)(3)(c), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEAC/DC DISCONNECT(S),APPLICABLE). NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). PER CODE(S):CEC 2019:690.13(B),NEC PER CODE(S):CEC 2019:690.53,NEC 2017:690.53 2017:690.13(B) Di WARNING WARNING DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: ADJACENT TO PV BREAKER(IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(BX3),NEC 705.12(B)(2)(3)(b),NEC 2017: 2017:705.12(8x3) 705.12(BX2X3)(b) ■�■ �• BUILDING SUPPLIED BY UTILITY FOR SOLAR PV SYSTEM GRID AND PHOTOVOLTAIC SYSTEM LABEL LOCATION: s u n r u n INSTALLED WITHIN 3'OF RAPID SHUT DOWN SWITCH PER CODE(S):CEC 2019:690.56(C)(3),NEC 2017:690.56(C)(3),IFC 2012:605.11.1,IFC 2018: .. 4•, __y 1204.5.3,CFC 2019:1204.5.3 SOLAR PV SYSTEM EQUIPPED 00825-ME �501MRLOTfEAVE,Hx](bY .11.1 WITH RAPID SHUTDOWN a"�°��°-'"' F A— ■• ■ SOURCE CUSTOMER RESIDENCE: CRAIG JOHNSON LABEL LOCATION: 20 MIDDLETON RD, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, GREENPORT,NY,11944 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3 TURN RAPID SHUTDOWN 4PV SYSTEM ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF' ry vAne�• DISCONNECT TEL.(401)578.6818 PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4), 1 POSITION TO SHUT DOWN NEC 2017:690.31(G)(3),690.31(GX4)IFC 2012: ANN: 605.11.1.4 PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE LABEL LOCATION: ARRAY, POINT OF INTERCONNECTION 216R-020JOHN PHOTOVOLTAIC AC DI • (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) •- DESIGNER: (415)5808920 ax3 NOMINALOPERATING • 4 CHRISTOPHER LUKE LABEL LOCATION: LABEL LOCATION: SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 ARE CONNECTED. PER CODE(S):CEC 2019:690.56(C)(1)(a),NEC 2017: REV:A 3/26/2022 690.56(C)(1)(a) PAGE PV-5.0 Harvest the Sunshine a\ 5++ \t \�~�'a\nFti�i•i5��`�ti\\\\�1� \�\\*\\\!!\\\\\\���'��� :311,.1\.4\\\\\'it•.��. ;:,. MBBModule JAMISICOD— Assembled D Series with mulMusbar - • • • of modules.e .e- of e - power output, better temperature-dependentperformance, reduced shading effect on • generation, • - of • spot, _ enhanced tolerance for •.• e Higher output power Lower LCOE Less shading and lower resistive loss "'Nr Better mechanical loading tolerance superior Warranty; Comprehensive Certificates • 12-year product warranty IEC 61215,IEC 61730, UL 61215,UL 61730 • 25-year linear power output warranty ISO 9001:2015 Quality management systems 100 ISO 14001:2015 Environmental management systems 87.5% • OHSAS 18001:2007 Occupational health and safety manage- e ment systems • IEC TS 62941:2016 Terrestrial photovoltaic(PV)modules— ®®® Guidelines for increased confidence in PV module design JA Linear Power Warranty ■ Industry Warranty ° a �o e: JASOLARSpecirications subject to technical changes and tests A Solar reserves the right of final interpretation off* JASOLAR JAM60S10 320-340/MR MECHANICAL DIAGRAMS SPECIFICATIONS 996:2 3511 Cell Mono Weight 18.7kg±3% Dimensions 1689±2mmx996±2mmx35±1mm Enlarge view of mounting hole(10.1) Cable Cross Section Size 4mma (12AWG) DorcundiT holes Pla eNo.of cells 120(6x20) Lill O o D mm Junction Box IP68,3 diodes A-A QC 4.10 (1000V) Mounting holes Connector sola«a QC 4.10-35 (1500V) Label Cable Length 9 Portrait:300mm(+)/400mm(-); DrainingtolesL (Including Connector) Landscape:1000mm(+)/1000mm(-) 8 places Packaging Configuration 30 Per Pallet Remark customized frame color and cable length available upon request ELECTRICAL PARAMETERS AT STC TYPE JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 -320/MR -325/MR -330/MR -335/MR -340/MR Rated Maximum Power(Pmax)[WJ 320 325 330 335 340 Open Circuit Voltage(Voc)[V] 40.60 40.87 41.08 41.32 41.55 Maximum Power Voltage(Vmp)[V] 33.73 33.97 34.24 34.48 34.73 Short Circuit Current(Isc)[A] 10.16 10.23 10.30 10.38 10.46 Maximum Power Current(Imp)[A] 9.49 9.57 9.64 9.72 9.79 Module Efficiency[%] 19.0 19.3 19.6 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_lsc) +0.044%/°C Temperature Coefficient of Voc([3_Voc) -0.272%/°C Temperature Coefficient of Pmax(y_Pmp) -0.350%/"C STC Irradiance 1000W/m', cell temperature 25°C,AM1.5G Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 TYPE -320/MR -325/MR -330/MR -335/MR -340/MR Maximum System Voltage 1000V/1500V DC(UL) Rated Max Power(Pmax)[W] 241 245 249 253 257 Operating Temperature -40"C-+85`C Open Circuit Voltage(Voc)[V] 38.05 38.26 38.46 38.68 38.90 Maximum Series Fuse 20A Max Power Voltage(Vmp)[V] 31.58 31.80 32.02 32.21 32.40 Maximum Static Load,Front 5400Pa(112 Ib/ft') Short Circuit Current(Isc)[A] 8.07 8.14 8.21 8.28 8.35 Maximum Static Load,Back 2400Pa(50 Ib/ft2) Max Power Current(Imp)[A] 7.63 7.70 7.78 7.85 7.93 NOCT 45±2°C NOCT Irradiance 800W/m',ambient temperature 20°C Fire Performance Type 1 wind speed 1m/s,AM1.5G CHARACTERISTICS Current-Voltage Curve JAM60S10-335/MR Power-Voltage Curve JAM60S10-335/MR Current-Voltage Curve JAM60S10-335/MR 350 10 1000W/m= 1000W/m' 10 10"C 300 80UW/m' -- 25`C 8 60UW/m' 250 -so'W/m' 8 40°C Q 400W/m' Q 55'C c 6 5000m' 200 200W/m' c 6 70°C 3 150 t (j 4400W/m' 0. ij 4 100 2 m 2 50 0 0 10 20 30 40 0 0 10 20 30 40 0 0 10 20 30 40 Voltage(V) Voltage(V) Voltage(V) ModulesPremium Cells, Premium solar =@ " • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/ SE7600H-US/SE10000H-US/ SE1140OH-US solar, -:[' .,,HD • solar=--- „�Mp W�25 ' rtanty O C) 9 r e O e asl • O � I V O 4 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring 1111191D Outdoor and indoor installation wove Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r ' • • z Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US / SE5000H-US/ SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US SE3000H-US 1 SE380OH-US SESOOOH-US I SE6000H-US iSE7600H-US SE10000H-US 1 su- 00H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 760010000 11400 VA .. .............................................. ................ ... . ................ . 000.e,208V. ................ .. o1 208V 5000 ................ ................. ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,E 208V, 5000.P,208V. ................ ................. ................. ........... .............................................. . ............... . ...... AC Output Voltage Min.-Nom:Max. ✓ _ ✓ _ _ - Vac ..0A-.208 229)........................... ............... ................ ................ . ✓ ✓ ....... ....... ....... ....... ....... .......✓....... ... .... AC Output Voltage Min.-Nom.-Max. Of ✓ ✓ Vac ........................... ................ ................ ................ ................. ................ ................. ................. ........... AC Frequency.(Nominal) 59.3-60-60.51i) Hz ............... ................ ................ ... ...... ................ ................. ................. ........... Maximum Continuous Output Curr ........ ent 16 24 A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A ..@240V..................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold 1 A . ............................................ ......................................................................................................................... ........... Utility Monitoring,Islanding Protection, CountryConfigurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W ...................... ................ .......... ................ ................. ................ ................. ................. ........... Maximum DC Power @208V 5100 7750 .............................................. ................ ................ ................ ................. ................ ................. ................. ........... Transformer-less Ungrounded....... Yes.......................................................... .......... Maximum Input Voltage.................. ............ 480 Vdc Nominal DC Input Voltage380 400 Vdc Maximum In ut Current 208V _...... 9...... ............ i.:5..... ....._...... .......... ..Maximum Input.Current @240V.......... ......8.5 ....I.....l�:s......1.....13:5......I......16:5......I......ZO.......I.......?�.......I......34:5...... ...Adc ... R.. ... Max.Input ircuit Current 45 AdcShort C .............................................. ......................................................................................................................... ........... Reverse-PolaritY.Pro...tectioYes .. ... ..on............... .............................................. ............................................................ ........... Ground-Fault Isolation Detection 600ka5ensitivity .......... .................... . ... .... ........ ...................................... Maximum Inverter Efficiency 69 99:2 ..... ........................... .................................................. CECWeighted Efficiency................... ...........................................................9.9........................................................... ....%..... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication InterfacesRS485,Ethernet,Zigeee(optional),Cellular(optional) ........... Revenue Grade Data,AN51 C12 20....... ......... ......... ........... .....................Optional1�1. ............................ .. . ....... ............ ........... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL3741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 . ......... ...... ........... Grid Connection Standards .... .............. IEEE1547,Rule 21,Rule 14(HI) ........ Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG ... uit'.i................ .......... ......................... ....... ..... .................... ........... DC Input Conduit Size/#of Strings/ 3/4"minimum/1-3 strings/ 3/4'.minimum/1-2 strings/14-6 AWG AWGRang?................................ ...........14:6 AWG............ ........... ........................................................... . Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm A 185 Weight...1 h Safety Switch............... .......22/.10.............1..251/11.4. I 26.2/11.9 .38.8/17:6 16.... F*- ... Noise <25 <50 dBA .............................................. .................................................................... .................................................... ........... Cooling Natural Convection Natural convection ....................................... . .............. ........... Operating Temperature Ranpe :13 to+140/:25 to+6d3i 40 F/:40 C option)I°I F/•C .................................. . .... Protection Rating NEMA 3R(Inverter with Safety Switch) Irl For other regional settings please contact SolarEdge support 111 Revenue grade inverter P/N:SEw H-USOOONNC2 131 For power de-rating information refer to:https://www.solamdge.com/sites/default/files/se-temperature-derating-note-na.pdf (41-40 version P/N:SEnmH-USOOONNU4 r,___. 0 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks r/.r- 1, / 1 Technologies. Snap rack k.corn - Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. Appealing design with built-in aesthetics No grounding lugs required for modules All bonding hardware is fully integrated Rail splices bond rails together, no rail :...• jumpers required . No drilling of rail or reaching for other tools required Class A Fire Rating for Type 1 and 2 modules System Features Include Q r Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling tJ1Rt u Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy Snaprack- snapnrack.com Solar Mounting Solutions Stainless Bolt with Stainless Steel ji,jBonding Splice Standard Rall 111 Split-Lock Washer Bolt with Split- Insert 015-09816 Lock Washer Bonding Adjustable End Clamp Top Bonding Splice Mid Clamp Base Bonding Bonding Adjustable Channel Nut Bonding End Clamp Bottom Channel Nut Stainless Stainless Hardware with Bolt with Split-Lock Washers Elr4 Lock Bonding Adjustable Bonding Mid Clamp Bonding Standard sher End Clamp 242-02053 Rail Splice Lug242-02067242-04015 -02101 12-6 AWG Copper Wire Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer Universal End Clamp 242-02215 Standoff Clamp l Assembly Rubber Serrated stainless—,#a Channel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree Stainless Standoff L Foot Flange Bolt All Purpose L Foot Mill Finish Standoff Metal Roof Base(7-Hole Mill Finish L Foot Base Assembly Base Shown) Flashing L Foot Base Metal Roof Base Standoff L Foot Base with Flashing with L Foot 242-92057 242-92050 242-02037 SERIES 100 TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill finish on select products Material Finish • Silver or black coated hardware Note:Appearance of mill finish products may vary and change over time. Wind Loads 110-190 mph (ASCE 7-10) Snow Loads 0 -120 psf Array Pitch 0 -60 degrees 877-732-2860 1 www.snapnrack.com contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions.All rights reserved S-pNrad,Se ,I00_B,.d­e-2.i