Loading...
HomeMy WebLinkAbout47828-Z �o�0gUEE01Town of Southold 11/4/2022 y� P.O.Box 1179 0 `n 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43558 Date: 11/4/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 150 Mayflower Rd.,Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-8-31 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/15/2022 pursuant to which Building Permit No. 47828 dated 5/18/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Occhiogrosso,Erin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47828 10/4/2022 PLUMBERS CERTIFICATION DATED th riz S gnature �o�SufFi al�,c� TOWN OF SOUTHOLD ay BUILDING DEPARTMENT y a TOWN CLERK'S OFFICE o . + SOUTHOLD, NY y o� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47828 Date: 5/18/2022 Permission is hereby granted to: Occhiogrosso, Erin 150 Mayflower Rd Mattituck, NY 11952 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 150 Mayflower Rd., Mattituck SCTM #473889 Sec/Block/Lot# 107.-8-31 Pursuant to application dated 4/15/2022 and approved by the Building Inspector. To expire on 11/17/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pF SOUryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.deviin(cb-town.southold.ny.us Southold,NY 11971-0959 olyMUM BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Erin Occhiogrosso Address: 150 Mayflower Rd city:Mattituck st: NY zip: 11952 Building Permit#: 47$28 Section: 107 Block: $ Lot: 31 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Long Island Solar Solutions License No: 46439H SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixtureTime Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 13.96kW Roof Mounted PV Solar Energy System w/ (40) Qcell qpeak duo G10 - 400W Modules Notes: Solar Inspector Signature: Date: October 4, 2022 p 9 S.Devlin-Cert Electrical Compliance Form SOUTyo�O # # TOWN OF SOUTHOLD BUILDING DEPT. °`ycourm '' 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] 'ROUGH PLBG. [. ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINALSO/M✓ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Moir, vo I F;v-wL - - Rmvl `v DATE INSPECTOR OE SOUIy�� f TOWN OF SOUTHOLD BUILDING DEPT. courm N 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ .] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL,;p/&/- [ ] FIREPLACE & CHIMNEY [ ] FIR AFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] F E RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: h L J Q, v , VA PI y fr 'PA-- �(k4kyw DATE 0 INSPECTOR .J' s to _ /� • ..- F^} �� IA 46 � ,�, g FIELD INSPECTION REPORT DATE COMMENTS, S . �J ►t7 . O'0 FOUNDATION(1ST) N y --------------------------------- FOUNDATION(2ND) ROUGH FRAMING& y PLUMBING O W �r INSULATION PER N.Y. STATE ENERGY CODE y FINAL Spr • N a 1s 'o , 1 ")gas me-ir bw t —wwG+ ve va,o-%- S % p ADDITIONAL COMMENTS i5f �G (� 23 2Z - AirJl 9 8 Wb L 4 s �_ o' o nr� - z rn O � Vtol o- 6 i A A- `o r N z W H o�SOFFotcoG: TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 y,9• a Telephone(631)765-1802 Fax(631)765-9502bgps://www.southoldtom=.aov Date Received APPLICATION FOR BUILDING PERMIT LFor Office Use Only PERMIT NO. l 1EBuilding Inspector: - .Applications and forms must be filled out in their entirety.Incomplete APR 1 5 2022 ID applications will not be accepted. Where the Applicant is not the owner,,an BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed: TOWN OF SOUTHOLD Date:March 16,2022 OWNERS)OF PROPERTY: . Name:Erin OcchiogMSSO _.1----------------. SCTM#1000- Project Address_150_Mayflower Road, Mattituck,NY, 11952 _ 4 . Phone#:(631) 466-1341 .. Email erinhalladay@gmail.com Mailing Address:150 Ma y,fl_ower Road, Mattituck,_NY, 11952 _ CONTACT.PERSONI: Name: / aX . _Gi� /_ Mailing Address..._. . - .4-2-3 / I Phone#: Email- DESIGN �.�j�_eS�3_(D.p_-..._..__.�.-_ DESIGN PROFESSIONAL INFORMATION: Name:Naresh K. Mailing Address:24-15 Metropolitan Ave 2nd floor,.Queens NY 11415 Phone#:516-884-2208„ _- .._..._.__.... _... Email;_f ling@srsolardesign.com CONTRACTOR INFORMATION:, Name:Surf Clean Energy inc, Mailing Address:670 Long_Beach Blvd Long,Beach NY 11561 Phone#+631-848-7093 _ _ Email:permitting@surficleanenergy�com�_�h DESCRIPTION,OF PROPOSED CONSTRUCTION ®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: they O (&-,— Pa ,eil< _ ,-bs, C� $66381.88 Will the lot be re-graded? ❑Yes R No Will excess fill be removed from premises? ❑Yes ®No 1 , .:u PROPERTYINFORMATION Existing use of property: �Qgsj� , Intended use of property: ��s Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to �s this property? ❑Ye o IF YES, PROVIDE A COPY. DCheck Bbx After Fieatling:,;Th'e owner/contractor/design professional�s responsitile'for atl dr"ainage and storm water issues as provided by :t Chapter 236 of the Town Code.,APPLICATION IS HEREBY MADE to the Building Department for the issuance.of a.Building;Permit pursuant to the Building zones Ordinance of the Town of Southold;Suffolk;.County;'New York and,other applicable,Lauds,Ordinances`or,Regulations;for the construction of buildings, _ additions;alterations or,for removal or demolition as,hereimdescribed:The applicant agrees to'comply with all applicable law"s;ordinances;building code;. housing code and r'egulattons-and to admit authorized inspectors'on-premises and inbuildtng(s)for necessary inspections:False statements made herein'are. punishable""as a-Class A misderne'' Opp, uant to Sect1on 21Q.45 of'tHe New.YorkState:Penal Law:; „•,` Application Submitted By(print name): L114 thorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) l b x11 Sbeing duly sworn/,'deposes and says that(s)he is the applicant (Name of in ividual signing cont ct) above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of J Q'y1 L/ , 20 Notary Public CHRISTOPHER TRAMANTANO PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YORK (Where the applicant is not the owner) N0.01TR6265544 Qualified in Nassau County �j My Commission Expires 10-12-2024 I, eoy\ 6e(, �OCI Y4 SJ'D residing at 44&A' +Vfk, JAY do hereby authorize 0,06= e* �Xr� iirt, to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date CHRISTOPHER TRAMANTANO v / NOTARY PUBLIC-STATE OF NEW YORK CC—`L�_b n S S No.01 TR6265544 Print Owner's Name Qualified in Nassau County My Commission Expires 10-12-2024 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, &(-i VA 0 X10 SS3 residing at 1 S'b /pilBi,� ��.✓ A- - (Print property owner's name) (Mailing Address) /dam #7'/V /VY do hereby authorize (Agent) / ,6r J, 'to apply f�vri i� 1/e Ce4- ' ply on my behalf to the Southold Building Department. (Owner's Signature) (Date) e� ®C"i n q a ssy (Print Owner's ame) AN.- 265 Sunrise Hwy Suite 1-173 Rockville Centre, NY 11570 C516-353-5360 om Lete info(&-completeexpediting.com Pvmw.completeexpeditin-g.com Expeditiong April 1, 2022 Town of Southold Building Department Town Hall Annex 54375 Main Road PO Box 1179 Southold, NY 11971 Re: 150 Mayflower Rd-Mattituck Solar Panel Application—Erin Occhiogrosso Dear Building Department, We are the Expeditor and represent the homeowner for the above listed address, enclosed is a Solar Panel Application. Please include us on any correspondence regarding this application. If you have any questions or further information is required, please contact us at 516-353-5360. Thank you, Mary Schr6lin4gg Complete Expediting (516) 353-5360 info@completeexpediting.com www.completeexpediting.com BUILDING DEPARTMENT-Electrical Int! PQR 15 2422 4 TOWN OF SOUTHOLD ,NG PT N Town Hall Annex- 54375 Main Road - 11����N OF se��p o.. ® Southold, New York 11971-0959 4,j0. a0�` Telephone (631) 765-1802 - FAX(631) 765-9502 rogerr(a-southoldtownny.gov— seandtd-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: March 16, 2022 Company Name: Long Island Solar Solutions Electrician's Name: John Totten License No.: H-46439 Elec. email:john@longislandsolarsolutions.com Elec. Phone No: 516-768-8876 ❑I request an email copy of Certificate of Compliance Elec. Address.: 22 HOLIDAY PARK DR CENTEREACH, NY, 11720 JOB SITE INFORMATION (All Information Required) Name: Erin Occhiogrosso Address: 150 Mayflower Rd Mattituck, NY 11952 Cross Street: Phone No.: (631)466-1341 Bldg.Permit M email: Tax Map District: 1000 Section: 107 Block: 8 Lot: 31 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 40 grid-tied roof top solar modules. Square Footage: 1922.40 Circle All That Apply: Is job ready for inspection?: ❑ YES❑✓ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: I YES❑NO Issued On Temp Information: (All information required) Service SizeFvl1 Ph❑3 Ph Size: 200 A #Meters 1 Old Meter# 98300628 Z New Service❑Fire Reconnect E]Flood Reconnect Oservice Reconnect[]Underground QOverhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION O��g�FFO(�coG BUILDING DEPARTMENT- Electrical Inspector � y TOWN OF SOUTHOLD h' Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr .southoldtownny.gov - seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/17/2022 Company Name: Long Island Solar Solutions Electrician's Name: John Totten License No.: 46301-ME Elec. email:john@longislandsolarsolutions.com Elec. Phone No: 516 768-8876 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 22 Holiday Park Drive, Centereach NY 11720 JOB SITE INFORMATION (All Information Required) Name: Erin Occhiogrosso Address: 150 Mayflower Road, Mattituck, NY, 11952 Cross Street: Harper Rd W Phone No.: 631 466-1341 Bldg.Permit#: 47828 email: erinhalladayggmail.com Tax Map District: 1000 Section: 107 Block: 8 Lot: 31 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Install a 16kw solar electric system with 40 400w solar modules on roof of house with 40 Enphase micro inverters AC combiner box with disconnect located outside wall next to PSEG meter. Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES ❑ NO -]Rough In r Final Do you need a Temp Certificate?: ❑ YES 0✓ NO Issued On Temp Information: (All information required) Service Size F11 PhF—]3 Ph Size: A #Meters Old Meter# El New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION DATE(MM/DDIYYYY) A�o® CERTIFICATE OF LIABILITY INSURANCE 02/16/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Philip O'Brien NAME: O'Brien Quick Agency PHONE F AIC o ExtI: AIC No): 402 Main Street ADDRESS.RDRESS. PhilipO@cquickinsurance.com INSURER(S)AFFORDING COVERAGE NAIC 0 Port Jefferson NY 11777 INSURERA: R-T Specialty/Lovullo INSURED INSURER B: Surf Clean Energy Inc INSURER C: 670 Long Beach BLVD INSURER D., INSURER E: Long Beach NY 11561 INSURER F: COVERAGES CERTIFICATE NUMBER: CL2221604424 REVISION NUMBER: THIS IS TO CERTIFYTHATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FORTHE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE INSD WVD POLICYNUMBER MMIIDDYEFF PMIDO EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENIFIF CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 50,000 MED EXP(Any one person) $ 10,000 A Y Y APP18097177 01/19/2022' 01/19/2023 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMITAPPUES PER: GENERAL AGGREGATE $ 2,000,000 POLICY ❑X JEST FILOC PRODUCTS-COMPIOPAGG $ 2.000,000 OTHER: Employee Benefits $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Fa accident ANYAUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTYDAMAGE $ AUTOS ONLY AUTOS ONLY Par.cadent UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION I PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETORIPARTNEWEXECUTIVE ❑ NIA EL.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory in NH) EL.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 107,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 NY-25 AUTHORIZED REPRESENTATIVE may. Southold NY 11971 /yam ©1988-2015/ACCORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD YORK workers'STATE CERTIFICATE OF INSURANCE COVERAGE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured SURF CLEAN ENERGY INC 631-848-7093 670 LONG BEACH BLVD LONG BEACH,NY 11561 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 825438387 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1a" 54375 NY-25 DBL659910 Southold,NY 11971 3c.Policy effective period 03/03/2022 to 03/02/2023 4. Policy provides the following benefits: [g A.Both disability and paid family leave benefits. E] B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 3/4/2022 By "d 4t (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title RlChard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 411,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Tide Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to Issue this form. DB-120.1 (12-21) 111111IP1°11111m0° illi) 11°2�°��°�°°11111 Additional Instructions for Form D13-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1 a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law.The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate is issued as a matter of information only and confers no rights upon the certificate holder.This Certificate does not amend,extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board,commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits,shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein,however,shall be construed as creating any liability on the part of such state or municipal department, board,commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board,commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. D13-120.1 (12-21)Reverse NYS1F New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE %sk ,^^A A A 825438387 SCS AGENCY INC1981 MARCUS AVE STE 125 LAKE SUCCESS NY 11042 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SURF CLEAN ENERGY INC. TOWN OF SOUTHOLD 301 WEST PARK AVENUE 54375 NY-25 Long Beach NY 11561 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE H2497146-7 469485 12/20/2021 TO 12/20/2022 2/16/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2497146-7, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COWCERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT TYLER MOSTON SURF CLEAN ENERGY INC A ONE PERSON CORP THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SURANCEFUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:748512130 W" e iC� � \ �'• ..-.-'ger „i+�i� �,i'i-...;...�•atia.:.�,,.�,'��:V�� tip): �, `,sig' i,� � -' '.: _.�i , < ..: •• yyam�`` ` raw`r f' +� Suffolk County Departmentof Labor, Licensing & Consumer Affairs VETERANS MEMORIAL HIOHWAY HAUPPAUGP,NEW YORK 11788 i 5/30/2019 SUFFOLK COUNTY 'Hom' e Improvement Contractor License This is to certify that TYLER MOSTON doing ���......��� having .. provisionspplicable laws,rules andreguiations of the County of Suffolk,State of New York is hereby licensed to conduct business as a HOME S < IMPROVEMENT CONTRACTOF�in the County of Suffolk. Additional Businesses Restric6ons r ^i 4 T 4r r 4 i • 1 WITHOUT, , +I DEPARTMENTAL .: .. 1 A CURRENT Y / ✓` CONSUMER C I ID CARDFrank • ` , „ P 1....,- : ._..._—••i 1 1 ti + 11 V J 't U •{�,��: ,.�. �� �� .r`.�,� _• '+ v�.'^Y�"`+ ,,,-• r _�,. ,r� .. -•cam APPROVED AS NOTED g, DATE: � B.P.# FEE: l 6 BY: _ NOTIFY BUILDING DE?ARTMENT AT . 765-1802 8 AM TO 4 P;M FOR THE FOLLOWING INSPECTIONS: ELECTRICAL 1. FOUNDATION - TWO REQUIRED INSPECTION REOUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR 0.0. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORRE STAND CONDITIONS OF CODES AS REQU `sn7HPi n ToWm p1 aNNING BOARD Ru USTEES . .S.DEC 'OCCUPANCY OR USE IS UNLAWFUL VVITNOUT CERTIFICAT OF OCCUPANCY DESIGN PROFESSIONAL'S CERTIFICATE OF COMPLIANCE To: Village of Mattituck Building Department Subject:Solar Panels at residence of:Erin Occhiogrosso 150 Mayflower Road, Mattituck. NY, 11952 Project Scope: Installation of Solar Panels on Existing Pitched Roof Application Number: N/A 1, Naresh K. Mahangu ' on behalf of the owner(s)of premises Known as 150 Mayflower Road,Mattituck, NY, 11952 submit the attached plans for your review and Issuance of Building Permit for the project referenced above. Please note the following conclusion regarding framing structure,roof loading,and proposed site location of installation: Existing roof framing: Conventional framing 2x6 at 16" o.c.with 13' (horizontal rafter projection). This existing structure is defiantly capable to support all of the loads that are indicated below for solar photovoltaic installation project. 1, Naresh K.Mahangu , License No.089068,certify that I am a Professional Engineer,duly licensed to practice In the State of New York and that I have inspected and analyzed the roof structure at the above-mentioned address and have determined the structure and the panel attachments to be adequate to support the new additional load imposed by the proposed solar panel system. The proposed system complies with the 140-mph wind design load as 2020 New York State Residential Building Codes and the 2017 National Electric Code(NEC)NFPA 70,and the ASCE 7-10 when installed in accordance with the manufacturer's instructions and standards. TABLE R301:2(1)CLIMATE AND OEOCiRAPHICAL,D,ESIGN CRITERIA. GROUND WIND WIND WEATHERING FROST TERMITE DECAY 1NINTER ICE FLOOD. SNOW, ZONE CATEGORY LINE DESIGN SHIELD HAZARDS LOAD DEPT TEMP. REQUIRED 30 140 B SEVERE:, 3 MODERATE SLIGHT TO 11 YES; NO 'FEET' TO HEAVY 'MODERATE DESIGN LOADING R301.4 AND R301.5 AND R301.6 NET'DESIGN WIND PRESSURE-ASCE 7-05' ATTIC W/O ATTIC:W/ ROOF NO ROOF W/ RAFTERS HAVING RAFTERS HAVING ROOF 0 TO 7 DEGREES[-33.0] STORAGE STORAGE CEILING CATHEDRAL SLQPES GREATER SLOPES GREATER ROOF,>7 T0;27 DEGREES,[5621 LOAD CEILING THAN 3112 WITH NO "THAN 3/12 WITH, FINISH;CEILING FINISH CEILING ROOOF,>27 TO 45 DEGREES[=30.4 ATTACHED ;ATTACHED, LL= 10psf LL 1Qpsf. LL-20psf LL=20psf LIM, U240 DL=1Upsf IDL=20psf IDL=,1,opsf DL;=15psf OF iV Q� Bvk K. �i,Qyr,I0 s N / Very Truly yours, 03/10/2022 Naresh K. Mahangu Signed 0 Date New York State License No.089068 O`cF$8IOt��` S&RSOLARDESIGN -15 METROPOLI'T'AN AVEIITUE I KEW GARDENS,NY 11415 PHONE:646-626-62991 FAX:(516)210-0141 FI LING@SRSOLARD ESIGN.COM RESluENTIALVOLTAlko �r 'STEM 150 MAYFLOWER RD, MATTITUCK, NY 11952, USA SURF CLEAN 40 MODULES-ROOF MOUNTED - 17.20 kW DC, 13.96 kW AC ENERGY -- SURF CLEAN ENERGY SHEETINDEX 111 SMITHTOWN BYPASS PV-1 COVER PAGE SUITE#207,HAUPPAUGE, PV-2 GENERAL NOTES NY 11788,USA PV-3 PLOT PLAN 15, PHONE NO.:(866)631-7873 PV-4 ROOF PLAN &MODULES REVISIONS PV-5 ATTACHMENT DETAIL DESCRIPTION DATE REV PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATIONS PV-8 PLACARDS PV-9+ EQUIPMENT SPECIFICATIONS ' SN K. fi 2 B �\ A9�fiFSS I ON PROJECT NAME&ADDRESS Q !0!^ 0 U) x N 0 Lo 0 0 Z LL U Q U o � 0 2 HOUSE PHOTO o — 17)1 r� �1�1 Z Ln r 5 ' PV-1 SCALE: NTS APR LOLL " # a10 Ll GOVERNING CODESQ DING DEPT (1J BUIL `iattituck, Y... TOIAIN OF SOOT ALL WORK SHALL CONFORM TO THE FOLLOWING CODES EQUIPMENT SUMMARY 1. 2020 RESIDENTIAL CODE OF NEW YORK STATE SHEET NAME 2. 2020 BUILDING CODE OF NEW YORK STATE COVER PAGE 40 Q CELLS Q.PEAK DUO L-G8.2 (430W) MODULES 3. 2020 PLUMBING CODE OF NEW YORK STATE 40 ENPHASE : IQ7A-72-2-US INVERTERS 4. 2020 MECHANICAL CODE OF NEW YORK STATE SHEET SIZE 01 AC DISCONNECT(FUSED) 5. 2020 FUEL GAS CODE OF NEW YORK STATE 01 ENPHASE COMBINER BOX 6. 2020 FIRE CODE OF NEW YORK STATE ANSI B 7. 2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE 11" X 17" 1 VICINITY MAP 8. 2020 EXISTING BUILDING CODE OF NEW YORK STATE 9. NEC 2017 NYS UNIFORM CODE SUPPLEMENT SHEETNUMBER PV-1 SCALE: NTS 10. ANY OTHER LOCAL AMENDMENTS PV-1 ,GENERAL NOTES THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY RECENT NATIONAL ELECTRIC AND BUILDING CODES AND STANDARDS, AS INTERCONNECTION, THE BREAKERNSHALL BE INSTALLED AT THE AMENDED BY JURISDICTION OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. SURF CLEAN • PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER • WHERE GROUND-FAULT PROTECTION IS USED, THE OUTPUT OF AN ENERGY' STRUCTURE IN ADDITION TO ANY OTHER ELECTRICAL SUPPLY SYSTEM(S) [NEC INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF SURF CLEAN ENERGY 690.4(A)] THE GROUND FAULT PROTECTION [NEC 705.32] 111 SMITHTOWN BYPASS • THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF SUITE#20NY 11788,1788,UPAUGE, USA INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, PHONE NO.:(866)631-78731 [NEC 690.4(C)] ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE REVISIONS • EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. DESCRIPTION DATE REV INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC • ALL THE NEC REQUIRED WARNING'SIGNS, MARKINGS, AND LABELS SYSTEM. SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY • INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT. PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORSs- CHARGE CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS, OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4 (B)] NOMINAL, MAXIMUM SYSTEM VOLTAGE FOR DC CIRCUITS, OR 30 VOLTS ri • ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), FOR AC CIRCUITS, SHALL REQUIRE TOOL TO OPEN AND MARKED "DO �( INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT °9 0 sg • ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN INTERRUPTING". [NEC 690.33(C) & (E)(2)] SS101A ACCORDANCE WITH NEC ARTICLE 250. • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH • SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 TERMINALS, LUGS, DEVICES, OR CONNECTORS IN ACCORDANCE WITH PROJECT NAME&ADDRESS • FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN NEC 110.14 6AWG SHALL COMPLY WITH NEC 250.120(C) [NEC'690.46] • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE Q • PV SOURCE CIRCUIT, PV OUTPUT CIRCUIT, INVERTER OUTPUT CIRCUIT, AND MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 0 Q U) STORAGE BATTERY CIRCUIT CONDUCTORS AND EQUIPMENT SHALL BE • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT PROTECTED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 240 [NEC AND APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15. 0 re re Lo 690.9(A)] • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE w M • OVERCURRENT DEVICES RATINGS SHALL BE NOT LESS THAN 125 PERCENT OF TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 0 THE MAXIMUM CURRENTS CALCULATED IN 690.8(A). [NEC 690.9(B)] 0 EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION O_ Oo Z • PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE V • PV DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS U Q j LOCATION EITHER ON THE OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S O o H NEAREST THE POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS [NEC RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ZLo 690.13(A)] ELECTRODE. W < • ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 • DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, • CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED "DO NOT "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT. DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC • CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO 690.33(E)(2)] CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER SHEET NAME • ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS VOLTAGE OPERATIONAL RANGE. GENERAL NOTES WHITE. [NEC 200.61 • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. SHEETSIZE • THE OUTPUT OF AN INTERCONNECTED ELECTRIC POWER SOURCE SHALL BE • ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS CONNECTED AS SPECIFIED IN NEC 705.12(A), (B), (C), OR (D). AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. ANSI B • THE HOMEOWNER IS RESPONSIBLE FOR ENSURING ALL EQUIPMENT 11" X 17" OUTSIDE THE SCOPE OFWORK IS NEC COMPLIANT. SHEET NUMBER PV-2 MODULE TYPE, DIMENSIONS &WEIGHT N NUMBER OF PANELS IN ARRAY=40 MODULES MODULE TYPE= Q CELLS Q.PEAK DUO L-G8.2(430W)MODULES MODULE WEIGHT=52.11 LBS/23.7 KG. MODULE DIMENSIONS = 81.88"X 40.55"=23.06 SF UNIT WEIGHT OF ARRAY =2144.40/9.11.20=2.35.PSF (E)STRUCTURE(TYP.) SURF CLEAN ENERGY SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, (E)FENCE NY 11788,USA PHONE NO.:(866)631-7873 REVI (05)Q CELLS Q.PEAK DUO OL--G8.2 1y1 3 / DESCRIP11ONSIONS DATE REV SLOPE:23,0 AZIM.:333°` i ROOF ACCESS POINT OwO� OaF� co Is 0 ROOF#4 (12)Q CELLS Q.PEAK DUO L-G8.2 SLOPE:23° AZIM.:63° OFFSSIONP�'� \ P _ p, �6a , �\ PROJECT NAME&ADDRESS O/ \JE i U) e ie D SN (!): Q� nj O) Lo r ISTORY HOUSE O 0 Z LLROOF#3 � 1�� 0. (15)Q CELLS Q.PEAK DUO L-G8.2 SLOPE:23 �5, CLo ~ AZIM.:2430 Z' r Q ROOF#2 W Z> (01)Q.CELLS Q.PEAK DUO L-G8.2 ROOF#1 SLOPE:23° (07)Q CELLS Q.PEAK,DUO L-G8.2 AZIM.:2430 SLOPE:23° \ / AZIM.: 153° SHEET NAME \✓/ (E)200A MAIN SERVICE PANEL TIED PLOT PLAN TO EXTERIOR.UTILITY METER' SHEET SIZE NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY ANSI B -SCALE AS SHOWN -INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME: NAME: 11" X 17" 1 PLOT PLAN -ALL DIMENSIONS IN FEET -INSTALLERS SHALL UPDATE NAME,ADDRESS,AND PHONE NUMBER OF ADDRESS: SHEET NUMBER PV-3 SCALE: 1"=2D'-o" UNLESS OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK PHONE NUMBER: PV-3: BILL OF MATERIALS N EQUIPMENT QTY DESCRIPTION ROOF#5 SOLAR PV 40 Q CELLS Q.PEAK DUO L-G8.2(430W)MODULES (05)Q CELLS Q.PEAK DUO L-G8.2 \ r \ \ MODULE SLOPE:23° INVERTER 40 ENPHASE:IQ7A-72-2-US(24OV)INVERTERS AZIM.: 333* SURF CLEAN AC DISCONNECT 1 LOCKABLE MAIN SERVICE DISCONNECT(FUSED) ROOF ACCESS POINT � V '� ENERGY 240/120 V 10,3W 1 OOA S NEMA 3R 125A ENPHASE IQ COMBINER+WITH BUILT IN RGM, 9 6 �. \\ \ \ \, \ -i E CHIMNEY SURF CLEAN ENERGY IQ COMBINER BOX 1 \ \ , \ ( ) NEMA 3R \ ,, ti \ �, � ,,. ' =' ,r (� 111 SMITHTOWN BYPASS ATTACHMENT 94 IRONRIDGEL-FOOTATTACHMENTS /�a \ ` /�/ r' r '` SUITE#207,HAUPPAUGE, RAILS 0 IRONRIDGE XR100 RAILS 132" 1e•p' .FpA H \ ` t / NY 11788,USA RAILS 20 IRONRIDGE XR100 RAILS 168" " RFp``� \ \,\� \ f r, �' O PHONE NO.: 866 631-7873 ra>� ( ) RAIL SPLICE 8 SPLICE KIT �� -' jf, ! \' r' REVISIONS MID CLAMPS 60 MID CLAMPS DESCRIPTION DATE REV END CLAMPS 40 END CLAMPS/STOPPER SLEEVE r GROUNDING LUG 10 GROUNDING LUG ROOF DESCRIPTION - -\� °`` �l q�SN K• Mq '�O ROOF TYPE COMP SHINGLE ROOF#3 J �� '✓ / r, f! r 92 (15)Q CELLS Q.PEAK DUO L-G8.2 r' ROOF ROOF AZIMUTH RAFTERS RAFTERS SLOPE:23* '� '' --' 9„'3 s i '' .••' \ x' TILT SIZE SPACINGi s ' AZIM.:2430 .-'"�.� ! `'' (40)ENPHASE: IQ7A-72-2-US lu #1 230 153° 2"x6" 16"O.C. ra - ' '�w- , �rte- '`• �" , ' -�" � (240V)INVERTERS A o #2 23' 243° 2"x6" 16"O.C. #3 23° 243° 2"4" 16"O.C. Yrlr i FSSIOS`lp`�' #4 1 23° 63° 2"4" 16"O.C. e ROOF#4 PROJECT NAME&ADDRESS #5 23° 333° 2"x6" 16"O.C. 'rr, r' r r ' (12)Q CELLS Q.PEAK DUO L-G8.2 SLOPE:23° AZIM.:63° SYSTEM LEGEND ' ;�r�- ' ! - r r ' r\ Q ROOF#2 ~ r� .\ '- \� �� 200A MAIN SERVICE PANEL&POINT OF —� (01)Q CELLS Q.PEAK DUO L-G8.2 �s 1 r - „, ' / \ is•F� qTH J ,O. 0 n INTERCONNECTION.TIED TO EXTERIOR SLOPE:23° J r' Q UTILITY METER AZIM.:243° `�' / \ \\.\\\\ \\ \ �' '\ '/ / c (��.� NEW PHOTOVOLTAIC UTILITY DISCONNECT % \ \ / 0 Lo C] SWITCH.LOCATED WITHIN 10'OF MSP. /J \ \ \ \ / w �� NEW DEDICATED PV SYSTEM COMBINER � �� ✓/r '\ �e�\1"a�PPa� \\\ \� \ \ \ \\ \\\ `\ \j� r PANEL. r / �a •iy \ \ J Z 40 NEW Q CELLS Q.PEAK DUO L-G8.2 O� �' ' - /\ \ \ ` \� LLMODULES WITH NEW 40-ENPHASE IQ7A-72-2-US INVERTERS,MOUNTED ON /f \ \\ �, �. ROOF#1 THE BACKOF EACH MODULES. 4O.rJrJ” ��' �� -Fir'r\� \\ \� i ` " r (07)Q CELLS Q.PEAK DUO L-G8.2 V ® / N JUNCTION BOX �Q� \ ZA 2 SLOPE:23 0 O (_- =FIRE PATHWAY O ( ) AZIM.: 153° Z Lo 1"EMT CONDUIT RUN IN ATTIC moo, r v ` Ir- 00 =ROOF OBSTRUCTIONS �Q �/� lT <�© \ �� (N)94-IRONRIDGE L-FOOT Q 00 ' ATTACHMENTS @ 48"OC =ATTACHMENT POINTS 00 (N)IQ COMBINER BOX 9 W _ -- =RAFTERco (N} FUSED AC DISCONNECT 0- (N)IRONRIDGE XR100 RACKING SYSTEM =RACKING SYSTEM SHEET NAME Q CELLS Q.PEAK DUO (E)UTILITY METER =EXTERIOR RUN L-G8.2(430W)MONO BLK (E)200A MAIN SERVICE PANEL TIED ROOF PLAN & MODULES TO EXTERIOR UTILITY METER MODULE - - =ATTIC RUN SHEET SIZE NOTES:, ARRAY DETAILS: PANEL TYPE: Q CELLS Q.PEAK DUO ANSI B 11." X 17" -SOLAR PANEL LAYOUT SUBJECT TO CHANGE TOTAL ROOF SURFACE AREA:2494.35 SQFT. L-G8.2 1 ROOF PLAN & MODULES ACCORDING TO EXISTING CONDITIONS TOTAL PV ARRAY AREA: 922.40 SQ FT. PANEL SIZE: 81.88"X 40.55" SHEET NUMBER -SCALE AS SHOWN PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY NUMBER OF PANELS: 40 �/-4 SCALE: 1"=10' -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED AREA/TOTAL ROOF SURFACE AREA)* 100.=36.98% SYSTEM SIZE: 17.200 kW PV-4 PV MODULE \ SURF CLEAN ENERGY SEE (2/PV-5) FOR SURF CLEAN ENERGY E 111 SMITHTBYPASS ENLARGED VIEW 0 G SUITE#207,HAUHAUPPAUGE, 'Ye NY 11788,USA �S d` (E) SINGLE LAYER OF PHONE NO.:(866)631-7873 �p.F�� " COMPOSITE SHINGLE REVISIONS DESCRIP710N DATE REV ���q�aEra�Ott, I �5 N 1 ATTACHMENT DETAIL 019 PV-5 A�OFFSSIONP�'�'��, PROJECT NAME&ADDRESS PV MODULES Q U O :D U) w N 0) IRONRIDGE XR100 RAIL T- ', O O _ uJZ (E) SINGLE LAYER OF IRONRIDGE INTEGRATED COMPOSITE SHINGLE U Q U GROUNDING & END/MID CLAMP O O H z Lo 5/16"X3" SS LAG BOLT WITH LL! MIN 2%2' THREAD EMBEDMENT, ALUMN. "L" BRACKET SEALED PENETRATION W/3/8" SS BOLT & NUT SHEET NAME IRONRIDGE L- FOOT 2"x6" RAFTERS @ 16" OC ATTACHMENT DETAIL SHEET SIZE ANSI B 11" X 17" 2 ATTACHMENT DETAIL (ENLARGED VIEW) SHEET NUMBER PV-5 PV-5 (40)Q CELLS Q.PEAK DUO L-G8.2(430W)MODULES (4)STRINGS OF 10 MODULES CONNECTED IN SERIES STRING. ENPHASE Q CABLE WITH SURF CLEAN #6AWG EGC ENERGY I CIRCUIT#1 I SURF CLEAN ENERGY { 1 2 0 0 0 9 10 I 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, NY 11788,USA 7 -J TO UTILITY GRID PHONE NO.:(866)631-7873 REVISIONS �1 + DESCRIPTION DATE IREV ""�-' '-- -"�" "-- -` --- -- ---- --r- - --tr-- --� BI-DIRECTIONAL UTILITY 300628 CIRCUIT#2 { 1-PHASE,38W 1120V/240V 1 2 0 0 0 9 10 { 9th I (4)#10 AWG THWN-2 LINE SIDE TAP { (4)#10 AWG TH �WN-2 5b ;5� K. �4 �O #8 AWG THHN GND �Pyq 3/4"EMT CONDUIT - (E)MAIN SERVICE _ PANEL,200A RATED,240V -----------�� �,=1 (N) 125A ENPHASE IQ u� COMBINER+ I WITH BUILT IN RGM,NEMA 3R ^ (E)MAIN BREAKER TO o 90 6 8 (X-IQ-AM1 -240-2)(N)JUNCTION BOX HOUSE 240 V,200A/2P 81 m4 ' { CIRCUIT#3 { 600 V, NEMA 3 (N)LOCKABLE MAIN ^ (TOP FED) { 1 2 0 0 0 9 10 { UL LISTED 15A SERVICE DISCONNECT PROJECT NAME&ADDRESS { FUSED)240/120 V 10. 20A -O (3W 00A S NEMA 3R _{ 20A ^ 80A Q 20A 0 U) w C 1 2 CI 00IT 0 9 10 I _ _ __ _ _ __ _._ __ IQ GATEWAY -S (3)#4 AWG THWN-2 GEC I., (1)#8 AWG THHN GROUND GROUNDING O O { 3/4"EMT CONDUIT ELECTRODE SYSTEM J Z LL - --------- I I U 2 0 z L~ 40-ENPHASE: IQ7A-72-2-US L j S SHEET NAME ELECTRICAL LINE DIAGRAM SERVICE INFO SHEETSIZE UTILITY PROVIDER: LONG ISLAND POWER AUTHORITY ANSI B MAIN SERVICE VOLTAGE: 240V 11"X 17" SERVICE PANEL: 200A 1 ELECTRICAL LINE DIAGRAM MAIN CIRCUITIBREAKER RATING: 200A SHEET NUMBER PV-6 SCALE: NTS MAIN SERVICE LOCATION: SOUTH EAST SERVICE FEED SOURCE: OVERHEAD PV-6 AC CONDUCTOR AMPACITY CALCULATIONS: SOLAR MODULE SPECIFICATIONS FROM ROOF TOP JUNCTION BOX TO LOAD CENTER MANUFACTURER/MODEL# Q CELLS Q.PEAK DUO L-G8.2 AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT (430"MODULES PER NEC 310.15(B)(2)(c): +22° VMP 41.70 SURF CLEAN EXPECTED WIRE TEMP (°C): 31°+22° IMP 10.31 ENERGY' TEMP CORRECTION PER TABLE 310.15: 0.76 VOC 49.33 #OF CURRENT CARRYING CONDUCTORS: 8 ISC 10.83 URF CLEAN ENERGY CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.70 81.88"L x 40.55"W x 1.37"D(In 111 SMITHTOWN BYPASS CIRCUIT CONDUCTOR SIZE: 10 AWG MODULE DIMENSION SUITE#207,HAUPPAUGE, CIRCUIT CONDUCTOR AMPACITY:40 A I I Inch) NY 11788,USA PHONE NO.:(866)631-7873 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): INVERTER SPECIFICATIONS REVISIONS 1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING MANUFACTURER/MODEL# ENPHASE IQ7A-72-2-US DESCRIPTION DATE REv CIRCUIT#1,#2,#3,#4 : 1.25 X 1.45 X 10 = 18.13A NOMINAL OUTPUT CURRENT 1.45 DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 NOMINAL OUTPUT VOLTAGE 240 VAC TEMP CORR. PER NEC TABLE 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X �PI CIRCUIT CONDUCTOR AMPACITY=0.76 X 0.70 X 40=21.28 A PERCENT OF NUMBER OF CURRENT � Q.�SN K. Mqy�O VALUES CARRYING CONDUCTORS IN EMT �P AC CONDUCTOR AMPACITY CALCULATIONS: .70 7-9 FROM LOAD CENTER TO MSP .50 10-20 A o8 EXPECTED WIRE TEMP (°C): 31° AMBIENT TEMPERATURE SPECS oFFssIONP�� TEMP CORRECTION PER NEC TABLE 310.15: 0.94 RECORD LOW TEMP -15° CIRCUIT CONDUCTOR SIZE:4 AWG AMBIENT TEMP (HIGH TEMP 2%) 31° PROJECT NAME&ADDRESS CIRCUIT CONDUCTOR AMPACITY: 85A #OF CURRENT CARRYING CONDUCTORS:3 CONDUIT HEIGHT 0.5" CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 ROOF TOP TEMP 53° < CONDUCTOR TEMPERATURE RATE 1 75*1 O REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(8): (n p 1.25 X OUTPUT CURRENT OF LOAD CENTER (n N 1.25 X 1.45 X 40= 72.50 A O Lo DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: 0 TEMP CORR. PER NEC 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X 0 z CIRCUIT CONDUCTOR AMPACITY= LL a Y 0.94 X 1.00 X 85= 79.90 A V O 2 :) Z L ELECTRICAL NOTES: Q 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. W 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.)WRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. SHEET NAME 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. WIRING 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY CALCULATIONS OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE SHEET SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. ANSI B 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE 11" X 17" GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. SHEET NUMBER PV-7 A ® s f• A - 07 i • • : ® � : ,- I i A ® ® ® ® SURF CLEAN ♦ ® LABEL LOCATION: E N E R•'G'Y` ®' -• 0 i ' INSTALL ON EACH INVERTER. • • PER CODE:NEC 2017 690.56(C) SURF CLEAN ENERGY p • , - ® • , 111 SMITHTOWN BYPASS SUITE 9207,HAUPPAUGE, NY 11788,USA LABEL LOCATION: PHONE NO.:(866)631-7873 INSTALL ON EACH PV AC DEVICE, ► °' A PRODUCTION METER,UTILITY METER REVISIONS PER CODE:NEC 2017 690.17(E),705.12(6)(3) ® • �• DESCRIPTION DATE REV • i • 1 � i ® LABEL LOCATION: r% I INSTALL AT PV CIRCUIT BREAKER ♦ • • ' '® LABEL LOCATION: WHEN BACKFEEDING *GJ=P�ySH K• y2�o� i • i •• • INSTAL ON EACH PV AC DEVICE PER CODE(S):NEC 2017 690.64, ® ® • ♦ ♦ . PER CODE:NEC 2017 690.56(B) 705.12(D)(2)(3)(B) Lc '• i i • i • i LABEL LOCATION: ERE= INSTALL ON EACH INVERTER. .9 . SS PER CODE:2017 NEC 690.35(F) OFFSSIOPlp'�� LABEL LOCATION: INSTALL ON PV SYSTEM PROJECT NAME&ADDRESS DISCONNECTING MEANS N mom PER CODE:NEC 2017 690.13(B) ® A BUILDING SUPPLIED BY UTILITY GRID (1) w N LABEL LOCATION: • ♦ - ® LO ADJACENT TO PVBREAKER(IF �• AND PHOTOVOLTAIC SYSTEM r' APPLICABLE). : • ® : . N LABEL LOCATION: O O Z INSTALL ON AC COMBINER A ® ® H ® ® A PER CODE:NEC 2017 690.64,as 0 111 V 705.12(D)(2)(3)(C) C LABEL LOCATION: ® O INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT �/� z Lc) EACH TURN,ABOVE AND BELOW PENETRATIONS,ON y N r EVERY JB/PULL BOX CONTAINING DC CIRCUITS. T LL Q PER CODE:NEC 2017:690.31(G)(3) <O W SHEET NAME e ®- -♦ • o PLACARDS LABEL LOCATION: F. AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT (N)LOAD CENTER --�� OF INTERCONNECTION. (N)AC DISCONNECT SHEET SIZE PER CODE:NEC 2017:60.54 (E) UTILITY METER A UAW ANSI B LABEL LOCATION: 11" X 17" POINT OF INTERCONNECTION SHEET NUMBER PV-8 pq vere itiy MECHANICAL SPECIFICATION - . �"`" Formai 2080mmx1D3Dmmx35mm(Ihcludlrigtramej Weight 25.Okg .3 r r •�"4:vf°�?... 04,.• r 1Front Cover � 3:2'mrrtthermally pre-sre.>sedglass with ., -- - - µ•�,��;s:;, _� --- ":� •. '. ,•a:"' *,r.:+w�'�`'�yr'�: l :f �^ aM,l-reflectientechniilogq��_�.....-.... a�.^.4..t.c:"m7 _ SURF CLEAN t3ackCovor ~Compcslte�ilm ..r::..«,.e•.a.,:..n.:..rw �- • r. { : a•x t C3ti.x c ue + I. Frame 4nodlsed alumin(umr_ ENERGY' Celt 8x.24=nocrystalllneG�lTI)M,°clar half calls t7 Junction box -"- 53-10+rrnx.32-6Dinmx16-18mm `- URF CLEAN ENERGY J', a FFotocdonclasslP57,withbypos 66(1as: x 111 SMITHTOVIM BYPASS o-4e+1 y..--.mss-. Caiste dmrr>zSolArcAhle;(+1�1000mm;(-)>_1�AQ'mm lr-''"� ••=•e--^, SUITE#207,HAUPPAUGE, connector Stgua 11 MCA-Evo2;1pQa, m NY 11788,USA PHONE NO,:(866)631-7873 REVISIONS i ® ELECTRICAL CHARACTLR'ISTICS DESCRIPTION DATE REV (7oP;8Rl1ND P0 ",'POWER CI A5S -^ 11 416420 426; 430'; to er mimmuM PERFbRMANcli AT STANDARD TFffi-c iiDiTioNS,STCS(POWER TOLERANCE+5Wj-0kV) ,- PomrstNIPP= P, [w1 :415: 420. 425 430 r 2018`2U17 ;2098 ttaU9' Short Circuit Current' IEc LAI 1DAg.'. 10.74 10.78 10.83' Open CinwitVoltagn' "Go Nq 4°8:59• 48.84 49.09 40.33 P►�'�a��e nt✓ I ,Fi Current at MPP IG [it), 10161022 10.27 10.31 5� �gtt K, j0 PhutI�� ` CkCEl15 VoltageatMPP Vva [V] 40.7,, 4108 4L39 4171Y- riQ `y !S1 '�YJ 92 •rmesxumr.: Efftcfoncy° 9 (%j' >19.4 c19.6 iI',3.8; e20.1 ,q ' r sttl��rsjoI1"no,9 MINIMUMPERFORMANCE ATNORMAL OPERATING CONDMONS,NM0T2 sorund e2o:c powvratMPP -- Pew. [W1 310.ft 314.5. 318.8 322.0 / r3CEll5• a Short Circuit Current isc 1411. 8.51 8.65. 8.69 _ 8J2 O Z� _'a? tea_. c Open Clrrult VDitag., yce Ill ?S:A. 46,0546.29 4652: E Curreatut_MPP p,W (Ai 8.01. 8:05 8.08 812` Voltage atMPPV,� C•7 38.79 39419 39:38 39.67' =P,4Ga51lreRL r¢Y0.alenrzd Pte"t346;'Icc:V�r595 at S'rC:;1000 W/rt�i 2512"C_,atdl'b ecrorc9ng m•IEC:80904-3•'BDO:N/m�,t�ACST;spesu[im Ah415' Q.ANTtJKT.EC`fiNOLOGY:LOW LEVELISi-D,COST OF ELECTRICITY' O CELLS PERF.tORM/1NCE WARRANTY pERFORMANCEAT WW,iRRADIANCE ' PROJECT NAME&ADDRESS C,` Hf her eld er.sUrface area,lower BOS'c6St§,ht her Ewer °0 _°«= at t9&�ct d f ll O 9 }� P 9 _P a ..... W_ffi n nomnru'owr, ur- --r-=--r`--=-r-----'t-----, Cie '. rt)(ti10VATIIIEPLf_-GVc/aALL-WEATHER b �pa•••u os2859Gom pl tov0eupa . - - c .. - x y'I" Ob . yeas w ' ----�;r1 --'-�ptimal.y[efds,✓hatevarthsweaJerwithexcellert a low-'lightandtemperete behaviour., aJe44nneasumttor- ® rrV^^J ;! I a , antes.Fullivansnticsinemardance; ,r° 4rf!h�thetvatrar'itytetirsf�ftfie` =°o ao° soo e°o rm°. V/ L.L (V ENDURING HIGHPERPORMANCE. 8 n �- Y � � GJCF..LLSsatesorivisatbnrtpur wnuAxct{varm2 LO Lon term Ield security t nth Anti LID Techb6I r paa9Je cpuntry„ 1f g- y itY " ogy,�Anti PID, �,,....� .. .. venins toa T alrmditeperorrranca undar !'irrrfJiarice NrrJi9ons in rwor+,mgn,vr .naai:t.>< ?:;, cocrpuisnritoSTC.coni3iiloo9{2b`CiJ.040Wlinr)� �•i• !� s' Technology,HD%Spot'Protect and Traceable Quality,Tra.Q� a, '7ENIPERATUR4COEFF iCIEWS;,, EXTREME WEATHER Pa Coefficient i � ce t , i%/!cl -Z27 K�'! OoH htech alurn mallgyfreme,certified for` Temperatio Loeiaientnr P, 0.35 NaminaMocule Operating Temperature NMOT (°LT 433 L� �. high sncnr✓(5400.Pa).and wend loads(2400Pajt _ L PROPERTIES FOR SYSTIOV,,DtSiGN. 5, U 41REi1AE3LEIFVti7ESTMEiVT Maz{mumSyatcmVoltaga 4. M 2500(IEC)/1500,(UL) PV modulecra'ssificatton t lasgil. 11 < ^V �y" ) incltsive.12-ye8ir-ptoduct'warrontyand 25-year Maximum Rab,amaCurient 1° [A] 20 Fire Rating hated onANS1/LIL1703 'C-/TYPEI \/ linear performande•v✓ailattyt. MO.Dnsigni-oad,Push/Pull °+' r [I?a1 3500/1600 Pormitte+iModutsTempdrawre -40"C',-+85°C �p Max,rest toad,Push/PWI (Pa1 $800/2400 an Coa(Inuars Dutyz LO l 'STATE OF.i"HE ART IMQD,ULE TECHNdLOGY? �! r ( r Q:kNTUM DUO combGieacttttinger3geeel[separation QUALIFICATIONS AND CERTIFICATES PACICAGJNG I�1FORi1J6ATlC�N a ,n innovati> 12-busbar design wiC3. th ANTUM Technology. TC - - ° 1 c •^.., ,..•••..---•°�`-^-- .. 1520161EC6173020161 NumberofModW utonporpallat 29 C Thlsde�,sheet rrnnp'.Ies Wth DIN EN 50380. Number of Peifets prr TraHer(24t) 24 =See data sheat an'rear for further inf6tnrtlon Q C EIR Number of Pallets per 4W HC-Centel nee(26t) 22 DVE a mug milutDisnenslons(L x W x HJ 2150,x1150:x 1220mm Mild weight 779kg 'a -- - - - pe SHEET NAME Notalrlstalbtienim&u&iorismmtt,'afdlbwed;See.ti,eirita}�ationafidp rstngftonuslcacatta#ourtectinicalsaniice;r[aparNiertferfratherirdoriratimptajjprovedhstalation p EQUIPMENT a;vJusoithispraii,rt., THE IDEAL SOLUTION FOR: hnaaainchJnte SPECIFICATIONS Rooftop morays on Qoutd-mounfef SHEET SIZE cs.•nrnercis1fhdu2trIal Sorwpower plartts Hamrha0CELLSAustrallaPly Ltd 6urdlnas Suite 1,Level LIS BUD Stree1:NadhSydney,NSW 2080;'Australia ITEL-61(D)2Vile30331t'Ax'=81-(4)290183032(.EMAILq-ceCs=austrdb@q-ce9s.comlWL•J3Lnmwq;cevawn/au ANSI B 11 tl X 17" Engineered In Germany -G.-CELLS Engineered in Germany acttlis SHEET NUMBER PV-9 Data Sheet Enphase IQ 7A Microinverter Enphase Microinverters SURF CLEAN Region:AMERICAS INPUT(DC) Ig7A.-72-2-uS ENERGY Commonly used module-pairings' 295 W-460'W+ ^ - - - - ----- — --- -------------- compatibility Module compatibility 60-cell-,66-cell,and 72-cell PV modulesURF CLEAN ENERGY -. .. .....___.._.._ .Maximum input DC voltage 58 V - -' - 111 SMITHTOWN BYPASS Power - ..--point - --tracking- ------voltage---- - •range--s -- - SUITE#207,HAUPPAUGE, 18 V-58 V --- - _ --- - ---- --- -- - - -- -- - -- !MinAMax,startv_nitage^ „-_•- 93.V/58V. ,,. � NY 11788,USA .a - ---'-....,._ -p-o' _... - --..,._..._ _ --___ .-- _..-_-__---- -- - - PHONE NO.:(866)631-7873 (.....__ ..ISC)3 15A The hi h- owered smart rid-read MaxDCshortcircuitcurrent module _..___...w,.___; _ .._„, .__..._._ _._ .__. ..._.. -_. ._._..____..............._....-_ _...__._.._..._._...._.._-_ P 9 Y I-Overvolrage class DC rt - 11 has43A _ ) REVISIONS a Enphase 4Q 7A Micro”"dramatically simplifies the DC pori backfeed current -- U A ---'- - - -- --_�__- ___.. _„_.__�_ .__.._-.__.-___.___ _ _-_ P 9highestV- -AC side protection requires ddi 20A per branch circuit DESCRIPTION DATE REV PV array configuration 1 x 1 ungrounded array;No additional DC side protection required: icr0inverter installation process while achieving the system efficiency for systems with 60-ceil and OUTPUT(AC) @ 240 VAC @ 208 VAC 72-cell modules. Peaxo�tpDtpower _ 366 VA 29svA _.,.__... ............. . . .. ._-_ -. .- - _._..__... ............ ......_. .._.._,.___._...- Maximum continuous out ut ower - - _ 349 VA 4A 211,•264 V 2U8 VA183-229 V _ '_'_ _ _ _ ___ _-P_ ?..r Part of the Enphase IQ System,the IQ 7A Micro Nomio�at�L L>voltage/range< - -' - -- - -- I paf�r Afith Maximum continuous output current 1 45 A(240 VAC) 1.39 A(208 VAC) J 5� 5H K. M �' integrates with the Enphase IQ Envoy°” Enphase IQ Noniinalfreque-ncy" _ 64 Hz _._. . __-.._ ................ ___.. . _._.,._._...___ i �� q0 BatteryTM,and the Enphase Enlighten'*"monitoring Extendedfrequencyrange AC short circuit fault current over 3 cycles 5.8 arms l andanalysis software. ,..__._._.-______ ..>_._._.,- _._...___._...___..__.. -...._-_. _... .._. ..._. ._.,.__ .__-- ..-.- -... ...........- ..--.-....'.-.-.---a..�.__-..__._... ,_. ..._ . .-.___a y Maximum units per 20 A(L-L)branch circuits 11(240 VAC) 11(208 VAC) r 1�, The IQ Series Microinverters extend the reliability OvervoltageclassACport _ III "" - ^F` __ -..,i standards set forth by previous generations and 6t3 _ .._.. .. Power factor setting 1.0 � 9 undergo over a million hours of power-on testing, Power factor(adjustable) 0.851eading.,. 0.851agging F'S 10140,' enabling Enphase to provide an industry-leading EFFICIENCY @240 vac @208 vac I CEC weighted efficiency 07.0% 96.5% ' PROJECT NAME&ADDRESS warranty of up to 25 years. MECHANICAL Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) High Power wet i;t'--type:-__� 1_.......... .... . . .__. (without Connecta t• e:CC _IQ7A-72.2•US P 12 mm x 175 mm x 30.2 mm(without bracket) g I _ - - .08 kg(2.38Ibsj ---- -J - - - - -- ''^^ Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Cooling Natural convection-No fans - - --- - -- -j v! 0 Approved for wet locations Yes Easy to Install Pollution degree PD3 !� • Lightweight and simple Enclosure - - Class 11 double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor V r' Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) --FEATURES } -------•— Communlcation,� Power Line Communication(PLC) Efficient and Reliable g Compatible with IQ Envy monitoring options = LL -. Q Envoy r 1 Monitoring Enlighten Manager and M Highest CEC efficiency of 97 io {__.._ -_.__ Optimized for high powered 60-cell and 72-cell modules bfsconnectiri mean disconnect Dqu red bctNEC ave been evaluated and approved�y UL for use as the load-break'' s g ., y _ , . � Y 690.�. C I� • More than a million hours of testing Compliance CIAR ule 21(UL 1741-SA) O UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, p Class II double-insulated enclosure CAN/CSA-C22.2 NO.107.1-01 Z L • UL listed This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. Smart Grid Ready W • Complies with advanced grid support,voltage and frequency ride- through requirements Envoy and Internet connection required 1.No enforced DC/AC ratio.See the compatibility calculator at hit(Z'lLe�phasg c4 4leiLOs�u(axLg71Lm4iJsile-comnati i11�ty. Configurable for varying grid profiles 2.CEG peak power tracking voltage range is 38 V to 43 V. SHEET NAME 3.Maximum continuous input DC current is 10.2A. Meets CA Rule 21 (UL 1741-SA) 4.Voltage range can be extended beyond nominal if required by the utility. EQUIPMENT 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. SPECIFICATIONS To learn more about Enphase offerings,visit enphase.com SHEET SIZE �p® p 52020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ a - �• E I V P'H A S E• Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. ICS !H ANSI I o To learn more about Enphase offerings,visit enphase.com �� 2020-06-16 O O 11" X17" SHEET NUMBER PV-10 (6 Data Sheet Enphase Networking' Enphase IQ Combiner+ SURF CLEAN ENERGY MODEL NUMBER SURF CLEAN ENERGY I10 Combiner+X-IQ-AMI-240-2 iq Combiner+with Enphase IQ Envoy'for integrated revenue grade PV production metering 111 SMITHTOWN BYPASS (ANSI C12.20+/-0.5%)and optional,'consumption monitoring(41-2.5%): i SUITE#207,HAUPPAUGE, ACCESSORIES(order separately) NY 11788,USA Enphase Mobile Connect' PHONE NO.:(866)631-7873 The EnriGiase IQ Combiner++'With Enphase ICELLMODEM-08(4G/12-year data plan Plug and play industrial grade cellular modem with data-plan for systemis up to 60EhphREVISIONS as a �CELLMOOEM-OT(3G/5-year data plan) microinverters.(Available In the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,L IQ Envoy's consolidates interconnection lConsumpCELLMODEM M'(4GLT CT y '•'R )._•_ there. is adequate cellular service in the installation area.) y - DESCRIPTION DATE REV mblner+ 0 e UI m ntintoasin le enclosure and Con OSPM-MI 4GringCT^Mi/5 aardata Ian Split . .._.__...__._. ..•,_ __..____ ..__ ...,.-. _._.w.,. q p g 9 p current transformers enable whole home consumption metering*{+/-2.5%). X-I AM1-d4D-2 _ w Q- � � o PV and storage installations by !Circuit Breaker,2 Ie, _ streamline • ' 15A,Eaibn BR215"- 4BRK 20A-2-240 Breaker,2 pole,20A,Eaton BR220 providing a consistent,pre-Wired solution for ELECTRICAL SPECIFICATIONS �cP K. cbQQ�sIA 4f residential applications. It offers up to four iRating Continuous.duty, Eaton vseriesbusbarrating-_._..---•._-.--. . y-125VAC,_.0 2-pole input circuits and Eaton BR series _ _ System voltage 240 VAC,60 HZ busbarassembly. t_.__-_._- -..--.-=--- - -__..,._._.._.__--- ____._.-. --_.-_ _.__ _`—.-- ------ Max.continuous current rating(output to grid) 65A "Max.fuse/circuit rating(output) 90A - - ( ..... -------------- -- - - - -------- Branch circuits --- solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) �0 B 68 I'lylax.continuous current rating{input from P,V) G4 A Max.total branch circuit breaker rating(input) 80 A(any combination) __,__ ,._._.-___.,..._...__._.-....___..._...p.:_. .-,- _._._._, _--_-.-.--_,.._._....__._._,_--...w_._._.._ PROJECT NAME&ADDRESS Production MeteringCT 200 A solid core re-installed and wired to IQEnvoy Smart MECHANICAL DATA 'Dimensions VJxHxD 49.3 x 46,5x 16 c 1 D 4 x 8.3"x6. y�' . -•,a,� '•� Includes lQEnvoy for communication �.._._._...-...,_:... .........._._...-_._.___..,_..._...__,._.._.,____...._._.. ._._...._..,..__._..___ ._.,.-.._...,____,._. .-.... .___._.._._.__m_..__-_..__.___ _._....._..__....-_._.._a., Q I „ and control Weight 75 kg(16.5 (16.5lbs) O _Am..b_ientteLerature+ra'n9eFlexiblenetworkin suPPortsWi-Fi, dD°¢to+46°C(40 to115 F)_ C_ol_: _ __.-.. ____....., _...... Etherne4,or cellular om9Natural convection,plus heat shield ,.t Provides production metering and optional 'Enclosure environmental rating Outdoor,NRTL certified,NEMA type 3R,.polycarbonate construction N consumptionmonitoring : ..______.;_..-=__.___._.,._ ._ ._,.--..,._.__-_._..__e 3R,-- _._-__.__....._...._.__.____._. ..._._ Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors n/ I Supports installation of the 60 A breaker branch input:3 to 1/0 AWG copper conductors LL Enphase Q Aggregator" Main lug combined output: 10 to 2/0 AWG copper conductors t'- 1` p Neutral and round: 14 to 1/0 copper conductors ,er Always follow cal code requirements for conductor ; �, rsiz O Slmple �Altltude To 2000meters(6,560feet), _ U- v, n ;f INTERNET CONNECTION OPTIONS �•• C •�'�• "� " *"'�" Eaton 8R series anelboard interior , '.` # l Up to four 2-pole branch circuits for 240 VAC tlntegrated Wi Fi 802.11b/g✓n .,, .,,°""� �°�R .• ;,;x t plug-in breakers(not included) Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable-not included h .. i�I E,, .•. b:��._ 80Atotal PV or g branch circuits - - - ------ - ---- - - - - _ ;Cellular Z LO Optional,CELLMODEM-01(3G)orCELLMODEM-03(4G)(not included} I C COMPLIANCE r ,. LL Reliable ICpmpliance,Combiner UC i741 ' i CANICSir C22.2 No.107.iUj Durable NRTL-certified NEMA type 47 CFR,Part 15,Class B,ICES 003• 3R enclosure Production mefenn ANSI 012.20 accuracy class 0.5(PV production) Five-year warranty Compliance,IQ Envoy UL 916 _ _ CAN/CSA C22.2 No,61010-1 • UL listed SHEET NAME *Consumption monitoring is required for Enphase Storage Systems. EQUIPMENT u`. SPECIFICATIONS To learn more about Enphase offerings,visit enphase.com SHEET SIZE LISTED ° � ���• 0 2018 Enphase Energy,All rights reserved.Ai trademarks or brands in this document are registereo by their respective owner. ENPHASE. To learn more about Enphase offerings,visit enphase.com- ° ' zale-os-o2 ' ANSI B 11" X17" SHEET NUMBER PV-11 ZZE IRONRIDGE XR Rail Family XR Rail Family SURF CLEAN The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific ENERGY Solar Is Not Always Sunny - design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. SURF CLEAN ENERGY 111 SMITHTOWN BYPASS Over their lifetime, solar panels experience countless SUITE*207,HAUPPAUGE, extreme weather events. Not just the worst storms in years, "�,, _�� ` NY 11788,USA _.,.�-•�` PHONE NO.:(866)631-7873 but the worst storms in 40 years. High winds capable of ripping panels from a roof,and snowfalls weighing t ____.. ! f _....____. ( ' REVISIONS enough to buckle a panel frame. �r ---- _ i ,11 DESCRIPTION DATE IREVI XR Rails are the structural backbone preventing • - these results.They resist uplift, protect 5' XR10 XR100 XR1000 Alp against buckling and safely and efficiently "yJ., 4 XR10Is a sleek,low-profile mounting XR100Is the ultimate residential XR1000 Is a heavyweight among jla F I transfer loads into the buildingstructure. •.,, P ;"•�',. � � rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle Their superior spanning capability "' ` p p � .,;,; .„,� ,,t�;-, no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and ons 12 feet or �G .<C•. "`' remaining light and economical. maximizing spans up to 8 feet more for commercial applications. P �q requires fewer roof attachments, = 2 reducing the number of roof 12'spanning capability capability B'spanning capability penetrations and the amount r P Moderate load capability Heavy load capability Extreme load capability ) ; cc • r _!if; •:�_f�tp` '-�•��,}, = �''*•::,�" �'���, -�_ ,` Clear anodized finish Clear&black anodized finish Clear anodized finish installation time. Internal splices available Internal splices available Internal rnal splices available Z1tu't ! `;'/�:-:::�`.�1,`�''''-_.�: -� s'� �<, � • Pesti • 0. r i Rail Selection FssioN " ^? The following table was prepared In compliance with applicable engineering codes and standards. Values are PROJECT NAME&ADDRESS t 9 P P P° PP 9° 9 . .- ;�.. I „ �., f, based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRldge.com for detailed span tables and certifications. (D c a r.. td��k�5ri ,,� _ t .`r i y '''F 1�1 1 '' - `j,-ti r1 ,,id� :Ft,. v� ,"r [ `•.� 'i,,yr•' r"' it Force-Stabilizing Curve Q�jri% 100 { ttt5 O Sloped roofs generate both vertical and lateral ' r forces on mounting rails which can cause them 120 ::�, to bend and twist.The curved shape of XR Rails None IK-- ` is specially designed to increase sUen th In both 140 XR10,, XR100 XR1000 � y-yxy N • � , r, t��17Rr; directions while resisting the twisting.This unique ILL? ? f, feature ensures greater Burin extreme 9 Y g 160 _ I _ ......_.. .__. r : w' s'. weather and a longer system lifetime. iJ :e',. 6 1 ti, a • , ,( 100 R Q V 120 Q F- C)r 4 fir{4 10-20 -- I' _ 140 Z LO 160 j Q 100 I UJ 30 160 Coma p tible with Flat&Pitched Roofs Corrosion-Resistant Materials " 100 k•� XR Rolls are ' •-r Iron Ridge offers All XR Rails are made of marine-grade �„`�, 40 ; jy, • SHEET NAME P g s r p :'`�,1 160 EQUIPMENT compatible with ,�,��Q'•`,.4 a range a1 tilt le alumJnum alto then protected with an ` ' FlashFoot and options for flat anodized finish-Anodizing prevents surface y----•-- — ' other pitched root <" roof mounting and structural corrosion,while also,providing ✓` 50 70 iso SPECIFICATIONS attachments. applications. a more attractive appearance. � �' - fi 80-90 160 SHEET SIZE ANSI B •A'i n.'f ir':ie;°;. tai"• ,t x - 't e r •err• n. >•t.° r: -mak ':•ti-:. �fw• 1. •�. �N�. _ _ _r s,..•, •: .:,. ,� :'. .�.`. _, SHEET NUMBER PV-12 RONRI DCBE; L=Foot SURF CLEAN ENERGY URF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAU PPAUGE, NY 11788,USA PHONE NO.:(866)631-7873 REVISIONS DESCRIPTION DATE REV pa4a�A�tbJ I A (jB Item Number Compnnenf qC 6S i, FOOT,EXTRUDED L-SLOTTED FFS81014 PROJECT NAME&ADDRESS Pert Number Description 'LFT-03-Mi SLOTTED.L-FOOT,.-MILL, LFT703.-131 SLOTTED L FOOT„BLACK, o < U cN 1) Foot, Extruded L-Slotted,, 0 Lo :42 r O 0 >- _ Uj Z —•-� .94 U Q V Oc � T7J'7, z L 1.22. 3:00W Q x.31 1.88,�`+' —�{ 1.92 SHEET NAME f EQUIPMENT Property I value SPECIFICATIONS Mafieribl Aluminum Finish I Mill BIQCIc SHEET SIZE v1.1o. ANSI B 11” X 17" SHEET NUMBER ,s � r d"'—'�;,'�„';!sc;p'm^.-;�"'r"'",i—.^"-'."�'t ^-.°�R`^'�°y'—r^,,,�F`..,•�',"�"£-�,e"•vrr�i,,v,�,^r^,..^�y�:� •�-..--^s^,^^v.t;�, ,.•—r*r�.;,•-^-T+•,^ �• tr. '' 1¢, $ i C` SLF�E y� a -rn jai y, •, ;t o PV-13 BILL OF MATERIALS ROOF#4 A N EQUIPMENT QTY DESCRIPTION 41 / 1 / SOLAR PV 40 Q CELLS Q.PEAK DUO BLK ML-G10+(400W) (05)Q CELLS Q.PEAK DUO BLK ML-G10+ MODULE MODULES SLOPE:23° INVERTER 40 ENPHASE:IQ7A-72-2-US(240V)INVERTERS AZIM.:333° �n�•1 c Qe, a �� SURF CLEAN LOCKABLE MAIN SERVICE DISCONNECT(FUSED) ROOF ACCESS POINT 4� b ENERGY AC DISCONNECT 1 240/120 V 10,3W 100A S NEMA 3R d,� ' IQ COMBINER BOX 1 ENPHASE IQ COMBINER X-IQ-AMI-240-3-ES 9A" (E)CHIMNEY SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#20THAUPPAUGE, ATTACHMENTS 102 IRONRIDGE L-FOOT ATTACHMENTSre Fi / NY 11788,USA RAILS 0 IRONRIDGE XR100 RAILS 137' ��'Fa � / \ O PHONE NO.:(866)631-7873 RAILS 21 IRONRIDGE XR100 RAILS 168" \ RAIL SPLICE 8 SPLICE KIT s ' \ REVISIONS MID CLAMPS 60 MID CLAMPS \ DESCRIPTION REV DATE END CLAMPS 40 END CLAMPS/STOPPER SLEEVE �9 \ w: 7/19/2022 t GROUNDING LUG 10 GROUNDING LUG Q Signature with Seal ROOF DESCRIPTION �� IS OF INV u� qP ROOF TYPE COMP SHINGLE m T o �S" K �,� yo ROOF#2 r 'rF i-, * �P yy2 9 ROOF RAFTERS RAFTERS (16)Q CELLS Q.PEAK DUO BLK ML-G10+ ROOF TILT AZIMUTH SIZE SPACING SLOPE:23° r� z ir #1 23° 153° 2"x6" 16"O.C. AZIM.:243° (40)ENPHASE: IQ7A-72-2-US #2 23° 243° 74" 16"O.C. (240V)INVERTERS Oqo 08 ea #3 23° 63° 2"x6" 16"O.C. FSSIONP�' #4 1 23° 1 333° 74" 1 16"O.C. cP \ ROOF#3 o, (11)Q CELLS Q.PEAK DUO BLK ML-G1 + PROJECT NAME&ADDRESS SLOPE:23° SYSTEM LEGEND 1 'IM.:63° O 200A MAIN SERVICE PANEL&POINT OF -� 'a'FRRP°grN \ �' INTERCONNECTION.TIED TO EXTERIOR A \ UTILITY METER � \© O � `(V NEW PHOTOVOLTAIC UTILITY DISCONNECT O 0 SWITCH.LOCATED WITHIN 10'OF MSP. QPtN fLLn LLI 'r__NEW DEDICATED PV SYSTEM COMBINER -T7 �� +gF� P�/ v LCD PANEL. !� ��� �° 0 0 40 NEW Q CELLS Q.PEAK DUO BLK O (P. //� 0 Z ML-G10+MODULES WITH NEW 40- a= `ac Y ENPHASE I07A-72-2-US INVERTERS, (� /6 U MOUNTED ON THE BACK OF EACH / ROOF#1 MODULES. i� ZL �f (08)Q CELLS Q.PEAK DUO BLK ML-G10+ V ® =FIRE PATHWAY 141 1 �� �� (N)JUNCTION BOX ` 2N fO SLOPE:23° c �- Q \ AZIM.: 153° 1"EMT CONDUIT RUN IN ATTIC z 141) r =ROOF OBSTRUCTIONS � �Q �j� (N)102-IRONRIDGE L-FOOT � Q =ATTACHMENT POINTS I !/^ y ATTACHMENTS @ 48"OC W ' (N)IQ COMBINER BOX M g" =RAFTER (N) FUSED AC DISCONNECT RACKING XR100 9 IR RASYSTEM E YSTEM --- =RACKING SYSTEM Q CELLS Q.PEAK DUO (E)UTILITY METER SHEET NAME- =EXTERIOR RUN BLK ML-G10+(400W) (E)200A MAIN SERVICE PANEL TIED ROOF PLAN &MODULE MONO BLK MODULES TO EXTERIOR UTILITY METER - - =ATTIC RUN SHEET SIZE NOTES: ARRAY DETAILS: PANEL TYPE: Q CELLS Q.PEAK DUO BLK ANSI B ACCORDING PANEL LAYOUT SUBJECT TO CHANGE TOTAL ROOF SURFACE AREA: 2494.35 SQFT. ML-G10+ 11" X 17" 1 ROOF PLAN & MODULES ACCORDING TO EXISTING CONDITIONS TOTAL PV ARRAY AREA: 844.8 SQ FT. PANEL SIZE: 74"X 41.1" SHEET NUMBER PV-4.01 -SCALE AS SHOWN PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY NUMBER OF PANELS:40 SCALE: 1"=10' -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED AREA/TOTAL ROOF SURFACE AREA)" 100=33.86% SYSTEM SIZE: 16.000 kW PV-4.01 ( 0)Q ELLS i.P K UO BLK 1_66"(400ODUL S (4)STRINGS OF 10 MODULES CONNECTED IN SERIES STRING. 1 ENPHASE Q CABLE WITH SURF CLEAN #6AWG EGC ENERGY 1 2 CIIRCU IT#1 9 10 URF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, NY 11788,USA I TO UTILITY GRID PHONE NO.:(866)631-7873 REVISIONS DESCRIPTION DATE REV 07/19!2022 1 BI-DIRECTIONAL UTILITY METER- 628 1 2 CIRCUIT U IT#2 9 10 I M 1-PHASE,,3 3-W-W 1120V/240V I (4)#10 AWG THWN-2 LINE SIDE TAP Signature with Seal (4)#10 AWG THWN-2 PCE OF NFh, #8 AWG THHN GND gra P�gH K / . q� O L- — ——— — — — — — —i 3/4"EMT CONDUIT (E)MAIN SERVICE 9 PANEL,200A RATED,240V , ` cr _---------- ` (N) 125A ENPHASE IQ b z COMBINER+ N WITH BUILT IN RGM,NEMA 3R (E)MAIN BREAKER TO va q °e 66 (N)JUNCTION BOX (X-IQ-AMI-240-3-ES) HOUSE 240 V,200A/2P OFFS I 1 2 CIoRCUIT#3 9 10 I 600 V, NEMA 3 sloNa` (N)LOCKABLE MAIN (TOP FED) UL LISTED15A SERVICE DISCONN T PROJECT NAME&ADDRESS (FUSED)240/120 V 0, I 20A 3W 100A S NE 3R L — - -- - - -- — -- 20A pA < I 20A �— U) " ----------- " 20A ——— — — — — —— — — U) W (V �- — -- - - - -- — -j I p Lo I w 1 2 CIRCUIT#4 GEC 9 10 I IQ GATEWAY J (3)#4 AWG THWN-2 O 0 } I- — — — — — — — — — (1)#8 AWG THHN GROUND GROUNDING 3/4"EMT CONDUIT ELECTRODE SYSTEM _j Z L — - -- - - - - — —I I U QU I I O 2 F-- ----------- O Z L L1. Q 40-ENPHASE: IQ7A-72-2-US LLI M SHEET NAME ELECTRICAL LINE DIAGRAM SERVICE INFO SHEET SIZE UTILITY PROVIDER: LONG ISLAND POWER AUTHORITY ANSI B MAIN SERVICE VOLTAGE: 240V 11" X 17" 1 MAIN SERVICE PANEL: 200A ELECTRICAL LINE DIAGRAM MAIN CIRCUIT BREAKER RATING: 200A SHEET NUMBER PV 6.01 SCALE:NTS MAIN SERVICE LOCATION: SOUTH EAST SERVICE FEED SOURCE: OVERHEAD PV-6.01 l &Z' RESIDENTIAL PHOTOVOLTAICS LAR SYSTEO 150 MAYFLOWER RD, MATTITUCK, NY 11952 , USA 1 SURF CLEAN 40 MODULES-ROOF MOUNTED - 16.00 kW DC, 13.96 kW AC ENERGY SHEET INDEX S111 URF CLEAN BPRGY S PV-1.01 COVER PAGE SUITE#20THAUPPAUGE, PV-2 GENERAL NOTES A NY 11788,USA PV-3.01 PLOT PLAN PHONE NO.:(866)631-7973 PV-4.01 ROOF PLAN &MODULES REVISIONS PV-5 ATTACHMENT DETAIL # DESCRIPTION DATE REV PV-6.01 ELECTRICAL LINE DIAGRAM Mar Er+EGXCHANGE 07/19/2022 1 PV-7.01 WIRING CALCULATIONS PV-8.01 PLACARDS PV-9.01+ EQUIPMENT SPECIFICATIONS Signature with Seal �p�(c OF NFA �52Pti5N K M-0�y�O9 c� m Z 2 N W F�9 oB BB aG`2� SS1011P PROJECT NAME&ADDRESS Q 0' U) W C) D U) W 04- 0 Wrn r 0 O Z _ LL U Q U low 2 HOUSE PHOTO z o PV-1.01 SCALE:NTS 1 � ' Mayflower GOVERNING CODES Mattituck, NY... � Lu � ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 40 EQUIPMENT SUMMARY 1. 2020 RESIDENTIAL CODE OF NEW YORK STATE SHEET NAME f 2. 2020 BUILDING CODE OF NEW YORK STATE 40 Q CELLS Q.PEAK DUO BILK ML-G10+ (400W) MODULES 3. 2020 PLUMBING CODE OF NEW YORK STATE COVER PAGE 40 ENPHASE : IQ7A-72-2-US INVERTERS 4. 2020 MECHANICAL CODE OF NEW YORK STATE SHEET SIZE {�x 01 AC DISCONNECT(FUSED) 5. 2020 FUEL GAS CODE OF NEW YORK STATE 01 ENPHASE COMBINER BOX 6. 2020 FIRE CODE OF NEW YORK STATE ANSI B 7. 2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE 11" X 17" 8. 2020 EXISTING BUILDING CODE OF NEW YORK STATE 1 VICINITY MAP 9. NEC 2017 NYS UNIFORM CODE SUPPLEMENT SHEET NUMBER -1.01 SCALE:NTS 10. ANY OTHER LOCAL AMENDMENTS PV-1 .01 V GENERAL NOTES THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY RECENT NATIONAL ELECTRIC AND BUILDING CODES AND STANDARDS, AS INTERCONNECTION, THE BREAKERNSHALL BE INSTALLED AT THE AMENDED BY.JURISDICTION OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. SURF CLEAN • PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER • WHERE GROUND-FAULT PROTECTION IS USED, THE OUTPUT OF AN ENERGY STRUCTURE IN ADDITION TO ANY OTHER ELECTRICAL SUPPLY SYSTEM(S) [NEC INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF SURF CLEAN ENERGY 690.4(A)] THE GROUND FAULT PROTECTION [NEC 705.32] 111 SMITHTOWN BYPASS • THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF SUIT NY 11788,USAUGE, INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, PHONE NO.:(866)631-7873 [NEC 690.4(C)] . ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE REVISIONS • EXISTING PLUMBING VENTS SKYLIGHTS EXHAUST OUTLETS VENTILATIONS PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. DESCRIPTION DATE IREV INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC • ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS W�� '�XE 07�19�zozz 1 SYSTEM. SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY • INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT. Signature with Seal PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS IS OF IV CHARGE CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS, OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4 (B)] NOMINAL, MAXIMUM SYSTEM VOLTAGE FOR DC CIRCUITS, OR 30 VOLTS • ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), FOR AC CIRCUITS, SHALL REQUIRE TOOL TO OPEN AND MARKED "DO N INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT `�°Ag. oe 66 • ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN INTERRUPTING". [NEC 690.33(C) & (E)(2)] °�FssloNa`�� ACCORDANCE WITH NEC ARTICLE 250. • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH • SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 TERMINALS, LUGS, DEVICES, OR CONNECTORS IN ACCORDANCE WITH PROJECT NAME&ADDRESS • FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN NEC 110.14 6AWG SHALL COMPLY WITH NEC 250.120(C) [NEC 690.461 • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE • PV SOURCE CIRCUIT, PV OUTPUT CIRCUIT, INVERTER OUTPUT CIRCUIT, AND MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 0 0 = STORAGE BATTERY CIRCUIT CONDUCTORS AND EQUIPMENT SHALL BE • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT PROTECTED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 240 [NEC AND APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15. 0 c W cN 690.9(A)] • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE W • OVERCURRENT DEVICES RATINGS SHALL BE NOT LESS THAN 125 PERCENT OF TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 THE MAXIMUM CURRENTS CALCULATED IN 690.8(A). [NEC 690.9(B)] • EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION O C� O >- _ Z • PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL.INCLUDE A RAPID POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, LL SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE C) Q U • PV DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS O LOCATION EITHER ON THE OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S Lo — NEAREST THE POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS [NEC RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING 690.13(A)] ELECTRODE. W < • ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 • DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, • CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED "DO NOT "CAUTION DC CIRCUIT" OR EQUIV..EVERY 5 FT. DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC • CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO 690:33(E)(2)] CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER SHEET NAME • ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS VOLTAGE OPERATIONAL RANGE. GENERAL NOTES WHITE. NEC 200.6 • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. WHITE. [NEC SHEET SIZE • THE OUTPUT OF AN INTERCONNECTED ELECTRIC POWER SOURCE SHALL BE • ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS CONNECTED AS SPECIFIED IN NEC 705.12(A), (B), (C), OR (D). AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. ANSI B • THE HOMEOWNER IS RESPONSIBLE FOR ENSURING ALL EQUIPMENT 11" X 17" OUTSIDE THE SCOPE OFWORK IS NEC COMPLIANT. SHEET NUMBER PV-2 MODULE TYPE, DIMENSIONS &WEIGHT N NUMBER OF PANELS IN ARRAY=40 MODULES MODULE TYPE=Q CELLS Q.PEAK DUO BLK ML-G10+(400W)MODULES MODULE WEIGHT=48.5 LBS/22.0 KG. MODULE DIMENSIONS = 74"X 41.1"=21.12 SF UNIT WEIGHT OF ARRAY =2000.00/911.20=2.19 PSF (E)STRUCTURE(TYP.) SURF CLEAN ENERGY URF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#20THAUPPAUGE, NY 11788,USA (E)FENCE PHONE NO.:(866)831-7873 ROOF#4REVISIONS 15 i (05)Q CELLS Q.PEAK DUO BLK ML-G10+ DESCRIPTION I DATE IREV SLOPE:23° \ uouoE,uvans 07/19/2022 1 CONBkJER-EAZIM.: 333° i Ot>? ROOF ACCESS POINT `QSignature with Seal je OF Ivp co K. y4 1O QROQE s ROOF#3 m (11)Q CELLS Q.PEAK DUO BLK ML-G10+ tp z ¢ SLOPE:23° AZIM.:63° 0qo°B as ��,a• 71 ,0 ESSIOtAP` 0 \O 0 PROJECT NAME&ADDRESS LLJ QEL Q � In 1-STORY �U? HOUSE b � � }Z QU ROOF#2 �� V (16)Q CELLS Q.PEAK DUO BLK ML-G10+ i 1y1 z H SLOPE:23° Lo i AZIM.:243* r LU ROOF#1 (08)Q CELLS Q.PEAK DUO BLK ML-G10+ SLOPE:23° \ / AZIM.: 153° SHEET NAME (E)200A MAIN SERVICE PANEL TIED PLOT PLAN TO EXTERIOR UTILITY METER SHEET SIZE NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY ANSI B -SCALE AS SHOWN -INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME: 11" X 17" 1 PLOT PLAN -ALL DIMENSIONS IN FEET -INSTALLERS SHALL UPDATE NAME,ADDRESS,AND PHONE NUMBER OF ADDRESS: SHEET NUMBER PV-3.01 SCALE: 1"=20'-0" UNLESS OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK PHONE NUMBER: PV-3.01 PV MODULE / SURF CLEAN ENERGY SURF CLEAN ENERGY SEE (2/PV-5) FOR 111 SMITHTOWN BYPASS ENLARGED VIEW / OG SUITE#207AUGE, I/ �6 NY 11788,788,USA �S @ (E) SINGLE LAYER OF PHONE NO. (866)631-7873 COMPOSITE SHINGLE REVISIONS 6 DESCRIPTION DATE REV 07/19/2022 1 Signature with Seal �p�E OF NEyy *� P�Sµ K. Mq l0 m m 1 ATTACHMENT DETAIL 08 68 PV-5 o`FssIoNP� PROJECT NAME&ADDRESS PV MODULES Q U) C) U) x 04 O of U-) IRONRIDGE XR100 RAIL � LIJ } Z (E) SINGLE LAYER OF IRONRIDGE INTEGRATED COMPOSITE SHINGLE U Q U GROUNDING & END/MID CLAMP O C) F- z 5/16"X3" SS LAG BOLT WITH � Q W � MIN 2%2" THREAD EMBEDMENT, ALUMN. "L" BRACKET SEALED PENETRATION W/3/8" SS BOLT & NUT SHEET NAME IRONRIDGE L- FOOT 2"x6" RAFTERS @ 16" OC ATTACHMENT DETAIL SHEET SIZE ANSI B 11" X 17" 2 ATTACHMENT DETAIL (ENLARGED VIEW) SHEET NUMBER PV-5 PV-5 AC CONDUCTOR AMPACITY CALCULATIONS: SOLAR MODULE SPECIFICATIONS FROM ROOFTOP JUNCTION BOX TO LOAD CENTER MANUFACTURER/MODEL# Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c): +22' VMP 37.13 SURF CLEAN EXPECTED WIRE TEMP (°C): 31°+22' IMP 10.77 ENERGY TEMP CORRECTION PER TABLE 310.15: 0.76 VOC 45.30 #OF CURRENT CARRYING CONDUCTORS: 8 ISC 11.14 SURF CLEAN ENERGY CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.70 111 SMITHTOWN BYPASS CIRCUIT CONDUCTOR SIZE: 10 AWG MODULE DIMENSION 74"L x 41.1"W x 1.37"D(In Inch) SUITE#207,HAUPPAUGE, CIRCUIT CONDUCTOR AMPACITY: 40 A NY 11788,USA PHONE NO. (866)631-7873 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): INVERTER SPECIFICATIONS REVISIONS 1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING DESCRIPTION DATE REV CIRCUIT#1,#2,#3,#4 : 1.25 X 1.45 X 10 = 18.13A MANUFACTURER/MODEL# ENPHASE IQ7A-72-2-U "�"D1�`"VO1i8 07/19/2022 1 CON&NER 80l(p1wNGE NOMINAL OUTPUT CURRENT 1.45 DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 NOMINAL OUTPUT VOLTAGE 240 VAC TEMP CORR. PER NEC TABLE 310.15 X Signature with Seal CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X CIRCUIT CONDUCTOR AMPACITY =0.76 X 0.70 X 40=21.28 A PERCENT OF NUMBER OF CURRENT *g�PQ S�K.NM Lam} VALUES CARRYING CONDUCTORS IN EMT r r� 4 yvy0 AC CONDUCTOR AMPACITY CALCULATIONS: .70 7-9 Z Q FROM LOAD CENTER TO MSP .50 - °B w m°v se EXPECTED WIRE TEMP (GC): 31' AMBIENT TEMPERATURE SPECS FSSION 'tiP TEMP CORRECTION PER NEC TABLE 310.15: 0.94 RECORD LOW TEMP -15° CIRCUIT CONDUCTOR SIZE: 4 AWG AMBIENT TEMP (HIGH TEMP 2%) 31' PROJECT NAME&ADDRESS CIRCUIT CONDUCTOR AMPACITY: 85A #OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT HEIGHT 0.5" CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 ROOF TOP TEMP 53° < CONDUCTOR TEMPERATURE RATE 75° O 0 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X OUTPUT CURRENT OF LOAD CENTER W � N 1.25X1.45X40 = 72.50A o Lo W> DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: (� TEMP CORR. PER NEC 310.15 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X = O z CIRCUIT CONDUCTOR AMPACITY = U 0.94 X 1.00 X 85 = 79.90 A U Q U O C � z Ln ELECTRICAL NOTES: W < 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. SHEET NAME 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. WIRING 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY CALCULATIONS OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE SHEET SIZE THEM ACCORDINGLY. ANSI B 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE 11" X 17" GROUNDING CLIP MANUFACTURER'S INSTRUCTION. SHEET NUMBER 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. PV-7.01 'WARNINGA-� PHOTOVOLTAIC HAZARDELECTRICAL SHOCK EQUIPPED" `• NOT TOUCHRAPID • SURF CLEAN TERMINALS ON BOTH SIDES L ENERGY MAY BE ENERGIZED IN THE LABEL LOCATION: OPEN •• • DUAL INSTALL ON EACH INVERTER. ENERGY POWER SOURCE: SURF CLEAN PER CODE:NEC 2017 690.56(C) U F CLEAN SMITHTOWN BYPASS • . SOLAR PV POWER SUITE#207,HAUPPAUGE, BE PRESENT NY 11788,USA PHONE NO.:(866)631-7873 LABEL LOCATION: INSTALL ON EACH PV AC DEVICE, ` REVISIONS PRODUCTION METER,UTILITY METER PER CODE:NEC 2017 690.17(E),705.12(B)(3) I DESCRIPTION DATE IREV DUAL POWER SUPP0wwou=,uroure • OMBNERBOXCHNGE 7/19/2022 1 SOURCES: UTILITY EAKER IS . AND • SOLAR ELECTRIJ LABEL LOCATION Signature with Sea{ INSTALL AT PV CIRCUIT BREAKER l • - LABEL LOCATION: WHEN BACKFEEDING /(EGF NF • •. • INSTAL ON EACH PV AC DEVICE PER CODE(S):NEC 2017 690.64, *r��P�gH K. y�y JG PHOTOVOLTAIC PER CODE:NEC 2017 690.56(B) 705.12(0)(2)(3)(B) UNGROUNDED AND MAY BE o` m ENERGIZED LABEL LOCATION: PHOTOVOLTAIC AC �4 08 6B INSTALL ON EACH INVERTER. 90r E� PER CODE:2017 NEC 690.35(F) DISCONNECT SWITCHFSSIOt1P- LABEL LOCATION: INSTALL ON PV SYSTEM PROJECT NAME&ADDRESS DISCONNECTING MEANS PER CODE:NEC 2017 690.13(B) - . • O U) BUILDING SUPPLIED BY UTILITY GRIDN LABEL LOCATION: • • • • - O 0) ADJACENT TO PVBREAKER(IF • • I AND PHOTOVOLTAIC SYSTEM 0� w APPLICABLE). CO- • - •• I n (D r • D • • . )I 0 OJ Z LABEL LOCATION: ® Z LL INSTALL ON AC COMBINER `1 tPHOTOVOLTAICPER CODE:NEC 2017 690.64, U POWER • - • . C 705.12(DX2)(3)tC)CE O G LABEL LOCATION: z INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND BELOW PENETRATIONS,ON n/ r EVERY JB/PULL BOX CONTAINING DC CIRCUITS. T LL Q PER CODE:NEC 2017:690.31(G)(3) l0 W PHOTOVOLTAIC ADISCONNECT MAXIMUM AC OPERATING SHEET NAME NOMINALOPERATING AC VOLTAGE: '' PLACARDS LABEL LOCATION: (N)LOAD CENTER SHEET SIZE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT UTILITY METER PER CODE NEC 201OF 17690.54 0:N. (N) FUSED AC ( ) SERVICE PANEL DISCONNECT (E) MAINS ANSI B LABEL LOCATION: 11" X 17" POINT OF INTERCONNECTION =NBEJR 1 powered bySURF CLEAN MECHANICAL SPECIFICATION DUO© Format ---------- -----___. _. ENERGY 74.01n x 41.1 in x 1.261n(including frame) (1879mm x 1045mm x 32mm) -eulur,.,n sse•uwe-I Weight 48.51bs(22.Okg) - SURF CLEAN ENERGY Front Cover 0.131n(3.2mm)thermally pre-stressed glass with ° pfe0nin' + a-�� ants-reflect on technology °• 111 SMITHTOWN BYPASS«�++•+•veld + Beck Cover Composite film r -Nee- SUITE#207,HAUPPAUGE, Frame Black anodized aluminum NY 11788,USA Cell 6 x 22 monocrystalline Q.ANTUM solar half cells C) ' PHONE NO.:(866)631-7873 Junction Box 2.09-3.981n x 1.26-2.36in x 0.59-0.711n (53-101mmx32-60mmx15-18mm),IP67,with bypass diodes � � aeas..ro REVISIONS Came 4mm2Solar cable;(+)z49.2in(1250mm),(-)149.2In(1250mm) DESCRIPTION DATE REV Connector St&ubli MC4;IP88 asarnlOLAO1T eoE 07/19/2022 1 »��.-im-Ivnrru Dawn• aeewae.w I�Ia.ee•eo-t -� Quality = I! A Controlled PV ELECTRICAL CHARACTERISTICS • • , (,-,� Signature with Sea) POWER CLASS ass Seo 395 400 406 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W!-0 W) E OF N N / , TOVRheinland Pt F/,y e .tw.wm Power at MPP' PN„ [W] 385 390 395 400 405 �'� �gH K. � fO ID m1232615 Short Circuit Current' Isc [Al 11.04 11.07 11.10 11.14 11.17 e e e yR E Open Circuit Voltage` Vcc [V] 45.19 45.23 46.27 45.30 45.34 Current at MPP Iu [A] 10.59 10.65 10.71 10.77 10.83 mZ Q TW SSAND►v Voltage at MPP VNw [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' it 1%1 zlg.6 119.9 220.1 z20.4 z20.6 �O9 pB 68 a2� USA ZO21 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' OFFSSI OSa Warranty 0CELLS Power at MPP P_ [WI 288.8 292.6 296.3 300.1 303.8 .,�•,.., . Yield Secunty E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 c Open Circuit Voltage Vac [V] 42.62 42.85 42.69 42.72 42.76 PROJECT NAME&ADDRESS BREAKING THE 20%EFFICIENCY BARRIER Current at MPP INw [A] 8.35 8.41 8.46 8.51 8.57 !nl III Q.ANTUM DUO Z Technology With zero gap cell layout Voltage at MPP VM°, (V] 34.59 34.81 35.03 35.25 35.46 ➢LWIl boosts module efficiency up to 20.9%. 'Measurement tolerances P„°,x3%;Isc;Vocx5%at STC:1000W/m2,25t2°C,AM1.6 according to IEC 60904.3.2800W/m1,NMOT,spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q THE MOST THOROUGH TESTING PROGRAMME INTHE INDUSTRY i �Am� Atleast98%arwminalpowercuring "' ] �0�1 Q CELLS is the first solar module manufacturer to pass the most comprehen- x thl - fa degradation a power to 10 06 years..A% r r 1 z v J sive quality programme in the industry:The new"Quality Controlled PV"of 4 r/� ni N the independent certification institute TUV Rheinland. r 25tl ole within measuremenpoweleast 86%ofnominalt tae enc- P a y J a �/J LJ- L0 INNOVATIVE ALL-WEATHER TECHNOLOGY reAll w aes.Full warranties in accordance with Optimal yields,whatever the weather with excellent +� •« ,eoo the warranty terms of the Q CELLS asaoulucE rv7rml R r" low-light and temperature behavior. o salsa orgenisation or your respective country. y ENDURING HIGH PERFORMANCE EPA6 comTypp)sodule ntoSTrformence under ns(25*C,10D W/M2 conditions In o •h ° ° comparison to STC conditions(25'C,1000 W/m') � J Z O Long-term yield security with Anti LID Technology,Anti PIDTEMPERATURE COEFFICIENTS d Technology',Hot-Spot Protect and Traceable Quality Tra.QTM'. Temperature Coefficient of is, a [%/K] +0.04 Temperature Coefficient of Voc d [%/KI -0.27 c? U >' Y Temperature Coefficient of PM„ y [%/K] -0.34 Nominal Module Operating Temperature NMOT (°F] 10915.4(4313°C) x U QU EXTREME WEATHER RATING 10 O G D High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN high snow(5400 Pa)and wind loads(4000Pa). Maximum System voltage Vs.s [V] 1000(IEC)/1000(UL) PV module classification Class 1I o Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 A RELIABLE INVESTMENT o p� Max.Design Load,Pueh/Pull' [lbs/ft'] 75(3800Pe)/55(2680 Pa) Permitted Module Temperature -40°F up to-1 o 3 � Inclusive 25-year product warranty and 25-year on continuous Duty (-40°C up to+86°C) u LU c linear performancewarranty2. Max.Teat Load,Push/Pun' pbs/e�] 113(5400Pa)/84(4000Ps) y$� e a See Installation Manuel 4 e eU98AR 12 aUEBAA 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION CELLTECHNOLOOY CELLTECHNOLOOY 'See data sheet on rear for further information. UL61730,CE- ,nPlkM, P ouelnyco-dledrV-TUVRi,ai�aea. ro'I �U IL SHEET NAME m IEC 612152019,IEC 61730:2019. THE IDEAL SOLUTION FOR: us.Pme,t Na.9.893,215(eow CNlel. s0® ` ere Horizontal 76.4in 43.31n 48.01n 1856lbs 24 24 32 1 EQUIPMENT C=us packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules Rooftop arrays on �»a SPECIFICATIONS residential buildings SHEET SIZE Nob:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. OCELLS ANSI B Hemehe O CELLS Amerles Ina, Engineered in Germany 400 SpectrumGenterDrive,Sulte1400,Irvine,CA92818,USAITEL+1849748599818MAILlnqulry®us.q-cells.comlWUwww.q-cells.us 11rf X 17" SHEET NUMBER PV-9.01 Data Sheet Enphase IQ 7A Microinverter SURF CLEAN Enphase Microinverters Region AMERICAS INPUT(DC) 107--72-2-Us ENERGY Commonly used module pairings' 295 W-460 W+ SURF CLEAN ENERGY Module compatibility 60-cell,66-cell,and 72-cell PV modules Maximum input DC voltage 58 V 111 SMITHTOWN BYPASS Power point tracking voltage range' 18 V-58 V SUITE#207,HAUPPAUGE, - -- -- -- Min/Max start voltage 33 V/58 V NY 11768,USA Max DC short circuit current(module Isc)' 15 A PHONE NO.:(866)631-7873 Enphase The high-powered smart grid-ready Overvoltage class DC port II REVISIONS PEnphase IQ 7A Micror"dramatically simplifies the DC port backfeed current 0 A DESCRIPTION DATE REV Q 7A M i c roi nverte r installation process while achieving the highest PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit 07/19/2022 1 system efficiency for systems with 60-cell and OUTPUT(AC) @ 240 VAC @ 208 VAC 72 cell modules. Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Part of the Enphase IQ System,the IQ 7A Micro Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V Signature with Seal Maximum continuous output current 1.45 A(240 VAC) 1.39 A(208 VAC) integrates with the Enphase IQ Envoy`",Enphase IQ Nominal frequency 60 Hz e OF W67 �Stt My Battery'",and the Enphase Enlighten"monitoring Extended frequency range 47-68 Hz K. )O* P y ,9 and analysis software. AC short circuit fault current over 3 cycles 5.8 Arms ?P Z t Maximum units per 20 A(L-L)branch circuits 11(240 VAC) 11(208 VAC) m The IQ Series Microinverters extend the reliability Overvoltage class AC port Ill at m AC port backfeed current 18 mA standards set forth by previous generations and m°o oe Power factor setting 1.0 q 68 undergo over a million hours of power-on testing, Power factor(adjustable) 0.85 leading... 0.85 lagging Op S104 enabl ng Enphase to provide an industry-leading EFFICIENCY @240 VAC @208 VAC warrant f U t0 25 CEC weighted efficiency 97.0% 96.5% PROJECT NAME&ADDRESS y Op years. MECHANICAL Ambient temperature range -40°C to+600C Relative humidity range 4%to 100%(condensing) Connector type:DC(IQ7A-72-2-US) MC4 Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) O High Power Weight 1.08 kg(2.38 lbs) (n C) Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Cooling Natural convection-No fans vJ 0� Approved for wet locations Yes O LN L L Easy to Install Pollution degree PD3 W 0) Lightweight and simple Enclosure Class II double-insulated,corrosion resistant polymeric enclosure r Faster installation with improved,lighter two-wire cabling Environmental category/UV exposure rating NEMA Type 6/outdoor O FEATURES O >_Built-in rapid shutdown compliant(NEC 2014&2017) --- — - -- - - Communication Power Line Communication(PLC) J Z Monitoring Enlighten Manager and MyEnlighten monitoring options 2 LL Efficient and Reliable Compatible with Enphase IQ Envoy U } Y Optimized for high powered 60-cell and 72-cell modules Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break r , Q U Highest CEC efficiency of 97% disconnect required by NEC 690. V C D More than a million hours of testing Compliance CA Rule 21(UL 1741-SA) O G UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, c) Class II double-insulated enclosure CAN/CSA-C22.2 NO.107.1-01 Z L0 F— This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and r UL listed NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. Smart Grid Ready __-_— ------____—� LIJ Complies with advanced grid support,voltage and frequency ride- through requirements Envoy and Internet connection required 1.No enforced DC/AC ratio See the compatibility calculator at hItAS:!/enoupgarilmodule-comoatihility. Configurable for varying grid profiles 2.CEC peak power tracking voltage range is 38 V to 43 V. SHEET NAME 3.Maximum continuous input DC current is 10.2A. EQUIPMENT Meets CA Rule 21(UL 1741-SA) 4.Voltage range can be extended beyond nominal if required by the utility. 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. SPECIFICATIONS ® To learn more about Enphase offerings,visit enphase.com SHEET SIZE (0 2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ E N P H A S E E N P H A S E Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. `� ANSI B To learn more about Enphase offerings,visit enphase.com `/ 2020-06-16 11" X 17" SHEET NUMBER PV-10 Data Sheet Enphase IQ Combiner 3-ES/3C-ES SURF CLEAN Enphase Networking MODEL NUMBER ENERGY IQ Combiner 3-ES X-IQ-AM1-240-3-ES IQ Combiner 3-ES with Enphase IQ Envoy printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver SURF CLEAN ENERGY solar shield to match the Encharge storage system and Enpower smart switch and to deflect heat. 111 SMITHTOWN BYPASS IQ Combiner 3C-ES(X-IQ-AM1-240-3C-ES) IQ Combiner 3C-ES with Enphase IQ Envoy printed circuit board for integrated revenue grade PV SUITE#207,HAUPPAUGE, h The Enphase IQ Combiner 3-ES/3C-ES'"with production metering(ANSI 012.20+/-0.5/)and consumption monitoring(+/-2.5%).Includes En p 1 1 ase Enphase Mobile Connect LTE-M1(CELLMODEM-M1),a plug-and-play industrial-grade cell modem for NY 11788,USA Enphase IQ EnvoyT'and integrated LTE M1 cell systems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin PHONE NO.:(866)631-7873 Q Combiner 3-ES/3C-ES Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield modem(included Only with IQ Combiner 3C- to match the Enchargestorage system and Enpowersmart switch and todeflect heat. REVISIONS ACCESSORIES and REPLACEMENT PARTS (not included,order separately) DESCRIPTION DATE REV X-IQ-AM1-240-3-ES ES)consolidates interconnection equipment - ----- ----- ----- ----— -- -- Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-M7 with 5-year data plan for Ensemble sites "ouou uY«,. X-I AM1-240-3C-ES (COMMS-CELLMODEM-M1) co"a"Eeaox—GE 7/19/2022 1 Q- into a single enclosure and streamlines PV and Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. storage installations by providing a consistent, BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 prewired Solution for residential applications. BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 Signature with Seal EPLC-01 Power line carrier(communication bridge pair),quantity-one pair It offers up to four 2-pole input circuits and OF XA-SOLARSHIELD-ES Replacement solar shield for Combiner 3-ES/3C-ES pCE Ni I! 4 Eaton BR series busbar assembly. 4tq XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3-ES/3C-ES(required for EPLC-07) 5, tisH K. )p� i XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3-ES/3C-ES ENPHASE ELECTRICAL SPECIFICATIONS ir Rating Continuous duty N00 =WW Smart System voltage 120/240 VAC,60 Hz 10 88 �0 Includes IQ Envoy for communication and control Eaton BR series busbar rating 125 A O�FSSIONP� Includes LTE-M1 cell modem(included only with Max.continuous current rating 65A IQ Combiner 3C-ES) Max.continuous current rating(input from PV/storage) 64A PROJECT NAME&ADDRESS Includes solar shield to match Ensemble esthetics and Max.fuse/circuit rating(output) 90A deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) i Flexible networking supports Wi-Fi, Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Envoy breaker included Q Ethernet,or cellular Envoy breaker 10A or 15A rating GE/Siemens/Eaton included O W Optional AC receptacle available for PLC bridge Production metering CT 200 A solid core pre-installed and wired to IQ Envoy W 0 Provides production metering and consumption Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers !/1 n/ monitoring MECHANICAL DATA O LL L0 Dimensions(W) 37.5 x 49.5 x 16.8 cm(14.75"x 19.5`x 6.63•).Height is 21.06"(53.5 cm)with mounting brackets. U-1 0) Simple Weight 7.5 kg(16.5 lbs) V r Reduced size from IQ Combiner+(X-IQ-AM1-240-2) Ambient temperature range -400 C to+46°C(-40°to 115°F) Centered mounting brackets support single Cooling Natural convection,plus heat shield O O Z r stud mounting Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction 2 LL Supports back and side conduit entry Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors U > Y Up to four 2-pole branch circuits for 240 VAC 60 A breaker branch input:4 to 1/0 AWG copper conductors / 1 Q plug-in breakers(not included) Main lug combined output:10 to 2/0 AWG copper conductors V C X-I0-AMI-240-3C-ES 80 A total PV or storage branch circuits Neutral and ground:14 to 1/0 copper conductors O C g Always follow local code requirements for conductor sizing. 0 I— Altitude To 2000 meters(6,560 feet) z to Reliable INTERNET CONNECTION OPTIONS r F� Cellular CELLMODE Q M- Integrated Wi-Fi 802.11b/g/n Durable NRTL-certified NEMA type 3R enclosure W Ml-06 4G based LTE-M1 cellular modem(included only with IQ Combiner 3C-ES). Five-year limited warranty Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Two years labor reimbursement program coverage Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) included for both the Combiner SKU's COMPLIANCE UL listed --------- — ----- - -- ---- --- _ - -- Compliance,Combiner UL 1741,CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 SHEET NAME Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 EQUIPMENT Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No,61010.1 SPECIFICATIONS U� X-IQ-AM7-240-3-ES SHEET SIZE LIMB � E N P H AS E To learn more about Enphase offerings,visit eenphase.com E N P H A S E To learn more about Enphase offerings,visit enohase.com %,/ 0 2021 Enphase Energy All rights reserved.Enphase,the Enphase logo.IQ Combiner 3C-ES,and other trademarks or service names \� are trademarks of Enphase Energy,Inc.Data subject to change.2021-05-26 ANSI B 11" X 17" SHEET NUMBER PV-11 .01 .% IRONRIDGE XR Rail Family XR Rail Family SURF CLEAN The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific ENERGY Solar Is Not Always Sunni loads, while minimizing material costs. Depending on your location,there is an XR Rail to match. SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207788,USAUGE, Over their lifetime, solar panels experience countless � NY 11788,USA extreme weather events. Not just the worst storms in years, db ..-n PHONE NO.:(866)631-7873 but the worst storms in 40 years. High winds capable of REVISIONS ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. DESCRIPTION DATE REV 07/19/2022 1 XR Rails are the structural backbone preventing xR10 XR100 XR1000 these results.They resist uplift, protect r against buckling and safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among Signature with Seal transfer loads Into the building structure, rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle Their superior spanning capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or P(E OF NFh, remaining light and economical maximizing spans up to 8 feet. more for commercial applications. oj� SH K. M requires fewer roof attachments, , PE -ay O reducing the number of roof 6'spanning capability 8'spanning capability 12'spanning capability penetrations and the amount Moderate load capability Heavy load capability Extreme load capability m t Clear anodized finish Clear&black anodized finish Clear anodized finish of Installation time. Internal splices available Internal splices available Internal splices available u' �o q OB 6B Rail Selection °�FssloNP`� The following table was prepared in compliance with applicable engineering codes and standards. Values are PROJECT NAME&ADDRESS based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Q Rail Span :I U) o Force-Stabilizing Curve 100W M Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them 120 to bend and twist.The curved shape of XR Rails None } is specially designed to increase strength in both 140 X1)0 XR100 XR1000 O O Z directions while resisting the twisting This unique 160U_ feature ensures greater security during extreme weather and a longer system lifetime. LJ 100 U Q U 120 � D 10-20 140 Z LF) H 160 Q 100 LLI 30 -- - 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 100 if XR Rails are l IronRidge offers All XR Rails are made of marine-grade �, 40 SHEET NAME compatible with �� a range of tilt leg aluminum alloy,then protected with an 160 EQUIPMENT FlashFoot and options for flat anodized finish.Anodizing prevents surface SPECIFICATIONS other pitched roof root mounting and structural corrosion,while also providing 5 -711 160 attachments applications a more attractive appearance. " SHEET SIZE 80-90 160 ANSI B - ----- 11" X 17„ SHEET NUMBER PV-12 IRONRIDGE L-Foot SURF CLEAN 21NERGY SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, NY 11788,USA PHONE NO. (866)631-7873 REVISIONS DESCRIPTION DATE REV 07/19/2022 1 Signature with Seal � OF N,c- 1PSSµ K. ka{ {O 0 M z Q N 4v Item Number Component F�a °e 68 I FOOT,EXTRUDED L-SLOTTED aFFsslot,P' PROJECT NAME&ADDRESS Part Number Description I FT-03-M I SLOTTED L-FOOT,MILL LFT-03-BI SLOTTED L-FOOT,BLACK O U) C U) cr- N 1) Foot, Extruded L - Slotted 0 W U') 12� LU .42 0 o Z U �TT Y .94 U G C) O ~_ z �- 1.22 E 3.00 + Uj OE 31 1.88 1.92 SHEET NAME I EQUIPMENT Property value Material Aluminum SPECIFICATIONS Finish I Mill Black SHEET SIZE V1.10 ANSI B 11" X 17" SHEET NUMBER PV-13