Loading...
HomeMy WebLinkAbout48255-Z �o�OS�FF p Town of Southold 12/2/2022 s� P.O.Box 1179 0 o • 53095 Main Rd ysj0 ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY. No: 43644 Date: 12/2/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3765 Wells Ave., Southold SCTM#: 473889 Sec/Block/Lot: 70.4-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/25/2022 pursuant to which Building Permit No. 48255 dated 9/6/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Hymes,Shari&Scheerer,Mary of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48255 11/10/2022 PLUMBERS CERTIFICATION DATED uth r' ed ignature �o�gUFFU��o TOWN OF SOUTHOLD ay BUILDING DEPARTMENT co z ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48255 Date: 9/6/2022 Permission is hereby granted to: Hymes, Shari PO BOX 1516 Southold, NY 11971 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 3765 Wells Ave., Southold SCTM # 473889 Sec/Block/Lot# 70.-4-3 - Pursuant to application dated 7/25/2022 and approved by the Building Inspector. To expire on 3/7/2024. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 v Building Inspector 4 o��OF SO!/j�,ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinO-town.southold.ny.us Southold,NY 11971-0959 �ycoum,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Shari Hymes Address: 3765 Wells Ave city:Southold st: NY zip: 11971 Building Permit#: 48255 Section: 70 Block: 4 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 11.2 kW Roof Mounted PV Solar Energy System w/ (28) Qcell Qpeak Duo 40OW Modules, 50A Disconnect, Combiner 220x3 215x1 Notes: Solar Inspector Signature: Date: November 10, 2022 S.Devlin-Cert Electrical Compliance Form- FIELD INSPECTION REPORT I DATE COMMENTS ro FOUNDATION (1ST) - I � ------------------------------------ I � FOUNDATION (2ND) O W H ROUGH FRAMING& PLUMBING W rnr INSULATION PER N.Y. O STATE ENERGY CODE fas t s Ca �s re!.4ml1f I FINAL NA - ADDITIONAL COMMENTS Z 9 �y o z rn 1 VJ r �v H O z d b �$ OF soUlyo� # # TOWN OF SOUTHOLD BUILDING DEPT. `ycouto, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST. [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [rSLATIOWCAULKING U FRAMING /STRAPPING [ NAL �o lWw"o' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 9�RAVI'i oz C 04 DATE / INSPECTOR 0f SOUlyolo `f SSS `37 We 11.. Ate # # TOWN OF SOUTHOLD BUILDING DEPT-. �o • �o `ycourm��' 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND = [` ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [' ] FIREPLACE &CHIMNEY' [ ] FIRE-SAFETY INSPECTION [ = ] FIRE RESISTANT CONSTRUCTION _ [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) *LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: DATE 101 INSPECTOR ''` �,�o�gpFPo1A l0 TOWN OF SOUTHOLD —BUILDING DEPARTMENT N ay$ Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownu.aov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ID PERMIT NO. ��LL"— Buildin Ins ector: JUL 2 5 gn99 g P BUILDING DEPT. Applications and forms must be filled out in their entirety.Incomplete TOWN OF SOUTHOLD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: —�— OWNER(S) OF AOPER : Name:-- I . �/iy � ���� SCTM# 1000 /J ,�►/ `/n�7 Project Address: �6 S "6— SU �1_- v /G / / Phone#: �l 7d Email: Mailing Address: 7 mjel6- Ae— CONTACT PERSON: Name:Danielle Rodger_ _ Mailing Address:7470 Sound Ave MattituCk NY 11952 Phone#:6317797993 Email:permits@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Element Energy_ LLC Mailing Address:7470 Sound Ave MattitUCk NY 11944 Phone#:6317797993 Eman:permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: DOtherSolar $ 7 f�Me/- Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ©No 1 Lono 6ign uocumem lu: I tN I`.JHZSK/-A6Ht$HH/115rtbKt fbM:1LV1/dJ2I I It4bUbVt PROPERTY INFORMATION Existing use of property: AVSi,4,773o-e Intended use of property: I&YL04��l17 f Zone or use district in which premises is situated: Are there any covenants and restrictions with respectto this property? ❑Yes ❑No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professlonal is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are 1. punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):­9 6?h /� Authorized Agent []Owner Signature of Applicant• Date: STATE OF NEW YORK) SS: COUNTY OF being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing co/�ntract)above named, (S)he is the . _ }�{,Q A - (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of - 20 (&j 0, N tary Public DEBRA A SEPULVEDA NOTARY PUBLIQSTA^rsoFr113W""PRO F ERTY OWNER AUTHORIZATION ge&tmdoaN&OISM12697 - QIIa>iaedia (Wh re the applicant is not the owner) MyCommisetoaExP1 A 5 residing at ��� do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Jul 212022 Owner's Signature Date Print Owne s Name 2 Sof fQ( JUL 2 �(�77 B LDING DEPARTMENT- Electrical Inspector 5 - TOWN OF SOUTHOLD ,w TOBIJI DI DUEDEPT wn Hall Annex- 54375 Main Road - PO Box 1179 y� Southold, New York 11971-0959 A,,o aO�ti Telephone (631) 765-1802 - FAX (631) 765-9502 roclerr(&-southoldtowriny.Qov �- seand(&-south6idtownrikaov APPLICATION -FOR-ELECTRICAL .INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date 71al L- Company Name: f Electrician's Name: 1,5; �, C License No.: Ste- /yJ� Elec. email: c if � .s- C Elec. Phone No: 77 � I request an email copy of Certificate of Compliance Elec. Address.: 6j f'� ,77-4& %� S JOB SITE INFORMATION (All Information Required) j Name: e � Address: 1i / Cross Street: 1 Phone No.: C- 31 - Bldg.Permit#: email: Tax Map District: 1000 Section: X7(1(1 Block; BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): E�,� rdG , Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESX] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES [XNO Issued On Temp Information: (All information required) Service Size[--].I Ph❑3 Ph Size: A #Meters Old Meter# _ ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect OU lderground❑Overhead #Underground Laterals 1 n2 .H Frame Pole Work done on Service? RY N Additional Information: i PAYMENT DUE WITH APPLICATION ! 00 q l�I�- powered by I 1 TOP BRAND PV-f i �l•, EUROPE Warranty 2021 O CELLS Product&Perfwmarce Yield Security a_ BREAKING THE 20%EFFICIENCY BARRIER n/I Ilnlll II Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent l� low-light and temperature behavior.; ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology,Hot-Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING C*7// High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year 1 linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) ]See date sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays ion n residential buildings Engineered in Germany OCIELLS MECHANICAL SPECIFICATION Format 74.0 in x41.1 in x1.26 in(including frame) a (1879mm x 1045mm x32mm) -74'0-(1H18mm) ss.e(3ss.smml 42.6'(1098mm) Weight 48.5lbs(22.Okg) Front Cover 0.13 in(3.2mm)thermally pre-stressed glass with 49Z(250 anti-reflection technology 1 ) 1 4xOm,n gpdI m0.39'(45_) Frena Back Cover Composite film 397(996mm) Frame Black anodized aluminum ® 411'(1045 Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes `°`"� z49.2(nsomml Cable 4mm2 Solar cable;(+)>49.2in(1250mm),(-)>_49.2in(1250mm) e.Drmn�nd� 4•M.-9d-(DETAR A) 1 Connector Staubli MC4;IP68 I I 1 DETAILA 0.83'(6") I I � OaV(24.5mn1 I�I0.33-(8.5-) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-OW) Power at MPP' PMPP [W] 385 390 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 EOpen Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 .5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMpp [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' 0 [%] .219.6 >_19.9 >_20.1 >-20.4 >:20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPp [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 'c 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMEP±3%;Isc;Voc±5%at STC:5000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3.2800W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE c'3 k 300 -°taus At least 98%of nominal power during 7 ao w a ne - n4vv me°ab,reQ.,°,mr°r 1 first year.Thereafter max.0.5% z n sP_ --------------------------- degradation per year.At least 93.5% V LOA --L_____1______1_ w° of nominal power up to 10 years.At - ?z` least 86%of nominal power up to 1 _.„__ 1 a ears. � --1------r-----1-----,------ z 2 0 ° 44 All data within measurement tolerant- m D ._..----------- ---------._ I I I I K w as.Full warranties in accordance with eo zoo 400 eoo aoa 3000 � the warranty terms of the O CELLS IRRADIANCENW] 9 o sales organisation of your respective g R 4 m m country. NI sad,.emm,m9�an�ro.lre iow�°�,e, YEARS Typical module performance under low irradiance conditions in v .ms°np�„oe�� n°smat��svc�zm41 comparison to STC conditions(25°C,1000W/m2) m m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc (i [%/K] -0.27 Temperature Coefficient of P_ y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 PROPERTIES FOR SYSTEM DESIGN a w Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) PV module classification Class II 0 tll Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 W Max.Design Load,Push/Pu113 [Ibs/ft2] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F o Max.Test Load,Push/Pu113 [[bs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40°C up to+85°C) o m 'See Installation Manual v U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m UL61730,CE-compliant, a3'Il ® m Ib EFO 4aHc % a Quality Controlled C 1730 Rheinland, cous O-Oo IEC 61215:2016,IEC 61730:2U.S.Patent No.9,893,215(solarcells), TWnM1eNstl Horizontal 76.4 in 43.3in 48.Oin 1656lbs 24 24 32 QCPV Certification ongoing. Cpackaging 1940mm 1100mm 1220mm 751 kg pallets pallets modulesma4 MUM 10 111122021) N Note:Installation instructions must be followed.See the installation and operating manual or contact ourtechnical service department for further information on approved installation and use of this product. Hanwhe 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 961 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us i Data Sheet Enphase Microinverters Region:AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 MicroTM and;Enphase IQ 7+ MicroTM IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ EnvoyTM, Enphase IQ BatteryTM, and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed ' 0 Smart Grid Ready 41=4 I-WIRk • Complies with advanced grid support,voltage and frequency ride-through requirements A - Remotely updates to respondto changing "w" grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-S i) U *The IQ 7+Micro is required to support 72-cell modules. L i EN PHASE. To learn more about Enphase offerings,visit enphase.com \./ Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27V-37V 27 V 45 V Operating range 16 V 48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15A 15 A Overvoltage class DC port II II DC port backfeed curren=t - 0 A _0_A_ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V_ Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39-A(208 V) ---- --- -- --- ----- - - - - -- ----- - - - - - ---- - - -- --- - Nominalfrequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current -O,A--,-,-- 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% I CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C i Relative humidity range 4%to 100%(condensing) or type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) ` ---- -------------- ------- --------.-. - _ --- - _ _-----_ -_- - - - - --- -- -- ------- Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. 1 Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httpS://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v EN PHAS E. @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 AW, IR®NRIDGE Flush Mount System �l Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish Clear and black finish • Clear anodized finish • Forms secure bonding Clamps & Grounding O UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware LOIN AEL - - t � ems_ � �f. I•` / Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Wind-driven rain tested • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • Mill and black finish • Secures 3/a"or 1"conduit • Clear and black finish • Assembled and lubricated Resources Design AssistantP NABCEP Certified Training t�ROG -_ — Go from rough layout to fully �� Earn free continuing education credits, engineered system. For free. NABCEP while learning more about our systems. _ Go to IronRidge.com/design Go to IronRidge.com/training SOLAR ARRAY ON MAIN 1OU5E 1 1 2 kVV DE5IGI4 6 DRAFTING BY: (28)QCELL Q.PEAK DUO ELK ML-G 10+ 400 WATT PV MODULES ELEMEIJT EIJERGY LLC (I)STRING OF(1 2) MICRO-INVERTERS a(2)STRINGS OF(8) MICRO-INVERTER5 REVIEW BY J.M.IJA13CEP CERTIFIED '(3)STRINGS TOTAL Vr TO UTILITY GRID 051112-129 STRING # I REVISIOAAT-- DE5CRIPTION I BI-DIRECTIONAL QF N EW UTILITY METER I C� t- ------------------- - P� 0 AyO I-PHA5E,240 V ------ ------ ------ --- GO 5TKING5 #2-3 _ r ��' `" A` �L m Lij - -- - - - - N 103443 !GCONTFACTOR= -t 1 ------ ------ ------ ------ ------ - --- ------ C NP iOk- H'. :E DS�J" i ' ENPt1A5E BRANCH MICRO-IN`JERTER CIRCUIT CABLE TYPICAL PNPr1A51 IQ7PLu5-7a2-U5 ELEMENT ENERGY. LLC. I I C40�'A:.. 2 A 97. �L_-r/ 7470 SOUND AVE '__VA AC DISCONNECT MATTITUCK, NY 1 1 952 LICENSE # 43889-H `-Q'A Gam. G LICENSE # 526(59-ME Q i r) ~ eLloG PROJECT NAME N N I MAIN SERVICE PANEL Ir----------- G ----- G -----------------------------------'t`___-_-__---__ 24.. ✓aC AC COMBINER BOX I I -'-��' N�JXXXTI W I I I I EXISTING GROUNDING [LJ ELECTRODE SYSTEM \ I / - Q } I _ w z 1 I EL/ J WIRE it CONDUIT 5CHEDULE � W CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% L 0 I.D. # ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE lJ 1 Ln 310.15;3)(3) 310.15(5);2a)/(3c) _ U INVERTERS COMBINER PANEL AWG#12 1 6 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I" 55�C 0.84 I I O FT 2.2% U [� O OR EMT � m COMBINER PANEL AC DISCONNECT AWG #6 I 3 I THWN-2 AWG#8 1 THWN-2 CU PVC 45oC 0.95 25 FT O.G% \ % i AC DISCONNECT MAIN PANEL AWG #G 1 3 I THWN-2 AWG#8 I THWN-2 CU PVC 45-C 0.95 10FT 0.6% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS I )ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL. AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 909C WET ENVIRONMENT [NEC 690.8(8)(1)]: (Isc) '(#of strmgs) (I.56) = 8.15 A 3-LINE DIA. 3.)WIRING, CONDUIT. AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY Modules per String M 12 AX. TO, AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE, HIP. OR VALLEY. ANiG#1 2. ampacity 'Temp Derate = 23.52 A 4 )WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 23.52 A > 18.15 A. therefo'-e DC wire size 15 valid. Modules per Inverter 1 COMPLY WITH NEC 1 10.2G. #2 Inverter Output Wire Ampacity Calculation Number of Inverters 28 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output ' (1.25) = 42.35 A Record low temp _109C FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACE55ORIE5 TO FULFILL AWG#G. ampaclty'(femp Derate)'(Conduit Fill Derate) = 7, 25 A Voc Temp Coefficient 0.24%/°C DRAWIIJG SCALE APPLICABLE CODES AND STANDARDS 71 25 A> 42.35 A. therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS 6.)WHERE 51ZE5 OF JUNCTION BOXE5. RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampacity Calculation CALCULATIONS 71�.P!-ONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 42.35 A OEeratinq Current 10.8 A =(#of strmgs)'(imp) N .T, 5 . 7 WIPE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AVVG#6. ampacity-(Temp Derate)'(Conduit Fill Derate) = 7 1.25 A Operatincl Volta e 37.1 V =(#modules in serles)'(Vm ) �'• ))ULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 71.25 A > 42.35 A. therefore AC wire size is vaba Max. System Voltage 49.G V = (#modules in series)'[(((-#.##%V/'C'.O 1)'(Lo Temp##°C-25))-(Voc))+(Voc)] ter}i'ORT RAIL, PER THE GROUNDIIJG CLIP MANUFACTURER- INSTRUCTION. Short Circuit Current 1 3.9 A =(#of 5tring5)'(15C)'(1.25)per Art. 690.8(A)(1) 9.)MODULE SUPPORT RAIL TO BE EONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR L5CO GBL-4C57 LAY-IN' LUG. AC SYSTEM SPECIFICATIONS SHEET wUMBER I 10.)THE POLARITY OF THE GROUNDED C014DUCI-OPS 15 (positve/negative) Max AC Output Current 42.35 A OR O eratin AC Volta e 240 V F)\/ 10.)THE DC SIDE OF THE PV SYSTEM IS UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000070000400003000 Town of SoutholdJuly 19th, 2022 Building Department �' . `f Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Scheerer Residence, 3755 Wells Ave. Southold, NY I[ II 11971 - i- RJUL 2 5 2029 To Town of Southold: ;. ?= BUILDING DEPT =; TOWN OFSOUTHOLD I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. i4 From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. S pV � ao A Q- G YO Great Eastern Services, Inc. �P KGs �ir PO Box 240 * 0 24 Harvey Rd Riverhead, NY 11901 2 `_ �O 103443 Office: 631.543.9555 SS OV, Mobile: 631.235.0189 Email: jerrygiustra@gmail.com DZ G C Q 0 77 D w iv y -n -4 z T 0 r —n C� C7 � -< � cmi� � p � w nzao -n n � n' m _m COQ z � � 0C)> C: zoo ® 0 � Mir- � rriz0 � D = v0 ^0 0-1 C p � � mm � n0 � > � > F- C cn -I - c� ' -z-� C „ � z � 7r Z Z - ZD-I � zzcnc� rn '.ri zQ cn -I G) M O —IrCJ90 0 Z� O 0C7 Cn = R 7J z y A 8 � �r _ zSnM c C � m � Zm mw � m cn w u z O0CA � m0m --4 z mc7 _ -a M ZOO0 -nz � ma rri C> {n � c = -i D:- pm � � m o -n S z 0 � s50 s rn z -4 m0 r- M PLI 1 ��'VV Zohn Sign Document ID:GOZWLKVHFRZWNGSTKJDMPX4XP3PILZV8FDMM26LDW1I DESIGN 6 DRAFTING 5CO I E Of 1 A UV/O p� L Greenport � ELEMENT ENERGY LLC NS' 2VOLTAIC (PV)SYSTEM AT THE SCHEERER RESIDENCE, Nom' E W REVIEW BY J.M.NABCEP CERTIFe LOCATED AT 3765 WELL5 AVE, 5OUTHOLD, NY 1 197 . 03 ! 12-I29 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS -''2 I` * -DESCRIPTION DATE F- OD• 5Y5TEM RATING ' � Shelter�1 kW DC STC EQUIPMENT 5UMMARYPecaric ,�' �. 28 -)CELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES �; A, 28 ffNPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS CONTRACTOR RONRInGE YR 100 MOUNTING SYSTEM Y 5I-I EET INDEX ELEMENT ENERGY. LLC. PV-I COVER PROJECT LOCATION 7470 SOUND AVE PV-2 SITE PLAN .. MATTITUCK, NY 1195 PV-3 ROOF PV LAYOUT r LICENSE # 43889-h PV-4 STRUCTURAL/DETAILS✓k SECTIONS .` ICENSE # 52689-ME PV-5 3-LINE ELECTRICAL DIAGRAM QF NEyV ` PV-G LABELS X, yO N GOVERNING CODES ° °� 2017 NATIONAL ELECTRICAL CODE. T- * hnS�j>� ' ; PROJECT IIAME 2020 RESIDENTIAL CODE OF NEW YORK STATE. (ti ASCE 7-1 G AND NFPA-70. ZN C� W 270 0 90' ° E r UNDERWRITERS LABORATORIES (UL/STANDARDS t ` OSHA 29 CFR 1910.269 �O 103443 �� 240° V 120° '_� W GENERAL NOTE5 AR�FEssloNP� 210180150° ,; z z S Q W 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT ' ,, '' — > THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE ', W HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK - (s z AGREE THE SAME. AERIAL VIEW Q 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED W J APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COM M ENT5 AND APPROVAL STAMP C O INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, W AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES W Ln I- 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO L �,D =) ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. U O JURISDICTION. I I . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR (� 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT pp FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. COVEI\ SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES 4 REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S DRAWING SCALE CERTIFICATION OF THESE PIANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS 8. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON � ETTHE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. ' `� •T• 5 SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER PROJECT FOR WHICH THEY ARE MADE IS EXECUTED ET NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE TH THTEN510NS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE s EET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV- I RESULT OF H15 WORK. TAX MAP: 1000070000400003000 ?oho Sign Document ID:(30ZWLKVHFRZWNGSTKJDMPX4XP3PILZV8FDMM26LDW1I LEGEND -i�OTE I .) THE ROOF SETBACK/PATHWAY SHALL NOT BE DE51 » "- BMANSERvICE PANEL REQUIRED TO ROOFS WHERE THE OPPOSITE OR ELEMLIJT ENERGY LLC A' REVIEW BY J.M.NABCEP CERTIF�,t7 NEW PV SUB–PANELS ADJACENT ROOF IS ACCESS ROOF IN ,V 051112-)29 A/C DISCONNECT ACCORDANCE WITH R324.G. I EXCEPTION OF Oo INVERTERS 2020 NYS RESIDENTIAL CODE. GND ELECTRODE , REVISIONS ®PV MODULE 0 4 DESCRIFiION DATE REv 079-2C —RACKING RAILo 0 ATTACHMENT POINT 6'x 36"GROUND ACCESS TYP. 40 D 490o ---RAFTERS - 2'00 120. r -*--ROOF PITCH ANGLE 7(1800 150o �SUNRUN METER l� ®VENT OPLUMBING VENT ®SKY LIGHT ®CHIMNEY / CONTRACTOR COMPOSTE GOOD CONDITION ON LPOTENTIAL SHADING ISSUES TRIM/R:MOVE AS NECESSARY j.. ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCIC. NY 1 1952 ACCESS ROOF / LICENSE # 43889-r1 _ICENSE # 52G89-ME i i i i 18"FIRE 5 ACK @RIDGE �� PROJECT IIAML j LLJ 18"FIRE SETB K @RIDGE W 15'- 10" zz m :N Q W 55 ROOF > _ ,n 18' o U-j � z LLJ z 11J Ln � 1 U 0 � m 14'-O2" 14'- 1 O2" 51IELT NAME IF NEw}' COP pg0 A G/GiS'O�p_ SITE FLAN 3:1 DRAWING 5CALE 103443 1 /8" �GFESSIONP CONSTRUCTION NOTES 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE StIEET CIUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. P\ /_ 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I v 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000070000400003000 ?oho Sign Document ID:GOZWLKVHFRZWNGSTKJDMPX4XP3PILZVBFDMM26LDW1I LEGEND CONSTRUCTION SUMMARY - MAIN HOUSE CONSTRUCTION NOTES DESIGN f DRAFTING BY: EXISTING UTILITY METER (28) QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEA' ELEMENT ENERGY LLC MAIN SERVICE PANEL (DIMENSIONS: 74"X 4 I .I"X I .3") WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 'Y REVIEW BY J.M.NABCEP CERTIFIED NEW PV SUB—PANELS 0 051112-129 A/C DISCONNECT (2 8) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH � COMBINER (50) ATTACHMENT POINTS @ G4"O.C. MAX. MINIMUM NEMA 3R RATING. ' INVERTERS GND ELECTRODE (194.I) LF IRONRIDGE XR 100 MOUNTING SYSTEM. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE ?J�o REVISIONS ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) FIELD VERIFICATION. DE5CRIPTI0N DATE =PV MODULE 240a p 17 RACKING RAIL D 90 o A O ATTACHMENT POINT .210. '?oo r ---RAFTERS G"x 3G"GROUND ACCESS TYP. JB�o 1$00 -*—ROOF PITCH ANGLE IS M-9SUNRUN METER ®VENT 0PLUMBING VENT ®SKY LIGHT 17,j CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUES ]POTENTIAL AS NECESSARY �` ELEMENT ENERGY, L 7470 SOUND AVE MATTITUCK. NY 1 1952 LICENSE # 43889-H r , AccessRooF LICENSE # 52G89-ME PROJECT NAME 18"FIRE 5ETBACK @RIDGE (Wl W 18"FIRE SETBACK @RIDGE v z QW _ > _ 2rn Q 1 1 11 /D ACCF55 ROOF LLJ � z __j ° LL. �" W 5_II � O In OF NEWY U m O C-1) � w L ARRAY#I ARRAY#2 SHEET NAME 8 MODULES 8 MODULE 0344 w/25MUTr ` �25°PITCH AR P� 151°AZIM UTF )00f DETAIL �FESS01 v 3.I 34 -- ARRAY#3 DRAWING 5CAL1 1 2 MODU "-%25-PIT 24I° LITH 'NOTE I .) THE kUUP `jL i bHc.r, F 1 HWAY SHALL NOT BE 5HEET NUMBER REQUIRED TO ROOFS WHERE THE OPPOSITE OR ADJACENT ROOF IS ACCESS ROOF IN FV-3 ACCORDANCE WITH R324.G. I EXCEPTION OF 2020 NYS RESIDENTIAL CODE, TAX MAP: 1000070000400003000 ?oho Sign Document ID:GUZWLKVHFRZWNG8TKJDMPX4XP3PILZV8FDMM26LDW1I LOAD CALCULATION ARRAY#I ARRAY#2 ARRAY#3 ITEM DE5C RIPTION ARRAY # TIIROUGII #3 DESIGN t DRAFTING BY RB RId e Bea m�BOard - ELEMENT ENERGY LLC R ROOF Rafter REVIEW BY J.M.NABCEP CERTIFIED MODULE WEIGHT(Lbs) 48.4 48.4 48.4 (D) Deckln - os 1 1 2-129 #of MODUI E5 8 8 12 (J) Cedinq J015t TOTAL MODULE WEIGHT(Lbs) 387.2 387.2 580.8 ' (P) Pitch REVISIONS TOTAL LENGTH OF RAIL(Ft) 55.5 55.5 83.2 X. ` QF NEYV y (P) PU IInS De5CRiP710N DATE O A G7 0 (h) 11or1zontal Span of R RAIL WEIGHT PER FOOT(Lbs) 0.68 O.G8 0.G5 CO TOTAL RAIL WEIGHT(Lbs) 37.7 37.7 5G.G (RB) #OF STRANDOFFS I 6 1 15Lu m (D) - WEIGHT PER 5TRANDOFf(Lbs) 2 2 2 TOTAL 5TANDOFF WEIGHT(Lbs) 32 32 36 �O �0r3443 TOTAL ARRAY WEIGHT(Lbs) 456.9 456.9 673.4 A�O' GSS01 POINT LOAD(Lbs) 28.4 28.4 37.4 CONTRACTOR TOTAL ARRAY AREA(5ci Ft) 1 7 1.3 1 7 1.3 254.9 ARRAY DEAD LOAD 05/5q ft) 2.7 2,7 2.G `LEMENT ENERGY. LLC. WIND DESIGN SUBJECT TO DAMAGE FROM 7470 SOUND AVE GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN F) SNOW Speed Topographic LIN #d Special Windbome DESIGN Frost DESIGN UNDERLAYMENT FREEZING ANNUAL ��A 15E # 4 -h NY I 95c LOAD' (mph) effects'` wind debris CATEGORYI Weathering' line Termite` TEMP' REQUIREDh HAZARDSa INDEX' TEMPI region' zone' depthb LICENSE # 52289-ME 20 140 NO NO NO B SEVERE 3 FT HEAVY 15°F YES 599 51'F MANUAL J DESIGN CRITERIA^ Indoor Heating Elevation Latitude Winter Summer Altitude design Design temperature PROJECT IIAIAE heating cooling correction factor temperature cooling -- - ���- - - temperature difference 106 FT 410 N 15°F 86'F 1.00 70°F 75°F 55°F /J� Cooling Wind Wind Coincident Daily Winter Summer l W W - temperature difference velocity velocity heating cooling wet bulb range humidity humidity \J F 77 [� 11°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH Q [J �� For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL - Q - a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength LU (S) z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined Q-/ J from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. J Q b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction ILI LLI J shall fill in the frost line depth column with the minimum depth of footing below finish grade. LU O C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. �/ _ d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined jLJ on a site-specific basis in accordance with Section R301.2.1.4. LL[ e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York = Ln State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also Vi r E Mau nT N CAMP O see Figure R301.2(1).] m (f) f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. 50AR MODULF (� g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New STAINLESS STEEL 3i8° York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the BOLT A Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. NRIDGF ALJM NUM R A - SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. A--V" v h. In accordance with Sections R905.1.2, R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." A,LJVINUM FLASHING I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) jTp I I I(�K// KU CT U - value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32°F)" ASPr1A,T 5niNGLE ROOF it. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 G"x G"5TAINLE55 jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. STEEL LAG BOLT WITH DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this art of the table with 2 E7 Mw THREAD g g ) P PENETRATION SEALED "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. WITH GEOCEL 4500 AS NOTE C m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the ;EQUIVALENT BETTER) DR table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (') See Figure R301.2(4)B. PV-4 TAX MAP: 1000070000400003000 MOUNTING DETAIL i ?oho Sign Document ID:(0ZWLKVHFRZWN(3STKJDMPX4XP3PILZV8FDMM26LDW1I DE51GN 6 DRAFTING BY: SOLAR ARRAY ON MAIN HOU5E 1 1.2 kW ELEMENT ENERGY LLC (28)QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES (1)STRING OF(1 2) MICRO-INVERTERS 3(2)STRINGS OF(8)MICRO-INVERTERS REVIEW BY J.M.05NABCEP CERTIFIE 12-1291112-129 '(3)STRINGS TOTAL TO UTILITY GRID REVISIONS STRING # I DESC RI PION DATE IT--------------------- _ - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- j X OF E�/�/y0 UTIILITYMETER O t- ------------------- v N A5EO ,2 V ------ ------ ------ ------ ------ -----' ------ ------ ------ ------ -----' CO- PRO A G PO (D) ; 64(A) INT OF INTERCONNECTION LE GT11 OF AP CONDUCTOR5 STRINGS #2-3 - - - _ - _ - - LU ""L NOT EXCEED 10 FT I IL L I 1 O 703445 CONTRACTOR 3 4 Ali I ' ------- - ---- ------ ------ ------ ---- - --_- ------n ILAR�FESSIONP� 91 A'N SERVICE DISCONNECT i I 1 -0 V.200A ENPHASE BRAN' J K I I CIRCJITCABLETYPICAL ENPHA5E0.�7PLJ5-72-2-os ELEMENT ENERGY, LLC. I I 240 VAC. 2 A 1 97.5%_Ec-wE1GdTED`-EF 7470 SOUND AVE VA �JLLsTe-� Ac DISCONNECT 1 1 MATTITUCI . NY 1 1952 T"FICA I LICENSE # 43889-H LICENSE # 52489-ME N L LI t t I I I I 1 2 PROJECT IIAML MAN SERVICE PANEL I N N ' r----------- G -----------------------------------+--------------_-� AC COMBINER BOX IN W W - G I I 1 I 1 EXISTING GROUNDING W ELECTRODE SYSTEM Q W - ' - / - I Q LLJ L----------------------------------------------------'� (� WIRE f- CONDUIT SCHEDULE L O CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(°f) W I.D. # ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE LI Ln 3 10.1 5(9)(3) 31 0.1 5(13)(2a)/(3c) INVERTERS COMBINER PANEL AWG#12 1 G 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1" 5512C 0.84 I 0 F' 2.2%OR EMT n COMBINER PANEL AC DISCONNECT AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 459C 0.95 25 F" O.G% AC D15CONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 THWN-2 CU PVC 45°C 0.95 O F- O.G% ELECTRICAL NOTES 5HEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS I.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL. AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER. RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC 690.8 B)(1)]: (I5c) '(#of 5tnn s)'(I.5G) = 1 8.1 5 A 3-LINE D I A 3.)WIRING, CONDUIT. AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY ( g Modules per Strvng 1 2 MAX TO, AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE. HIP. OR VALLEY. AWG# 2,ampa1 5y'Temp Derate = 23.52 A 23.52 A > 18 15 A.therefore DC were size is valid. Modules per Inverter 4,)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 28 COMPLY WITH NEC 1 10.24. #2 Inverter Output Wire Ampacity Calculation 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25) = 42.35 A Record low temp _101C FURNISH ALL NECESSARY OUTLETS, SUPPORTS. FITTINGS AND ACE550RIE5 TO FULFILL AWG#G. ompacity'(Temp Derate)'(Conduit Fill Derate) = 7 1,25 A Voc Temp Coefficient -0.24%/QC DRAWRJG SCALE APPLICABLE CODES AND STANDARDS. 71 .25 A > 42.35 A. therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS G.)WHERE SIZES OF JUNCTION BOXE5, RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampacity Calculation O eratln Current 10.8 A sten s)'(Im N ,T , THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 42.35 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G. ampaclty'(Temp Derate)'(Condult Fill Derate) = 71.25 A Operatinq VoltaLle 37. 9 es In 5eries)'(Vm ) 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 7 1.25 A > 42.35 A, therefore AC wire size is valid. Max. 5y5tem Voltage 49.G V - '# modules In series)'[(((-#.##%Vr'C' O!)'(Lo Temp##�C-2E SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A -;#of strip s)'((sc)'(1 25) per Art G9C.8(A)(I) 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEED LUG AC SYSTEM SPECIFICATIONS 5HEET NUMBER OR ILSCO GBL-4D5T LAY-IN LUG 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15 (positive/negative) Max AC Output Current 42.35 A P\/ OR O eratln AC Volta e 240 V I V - 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000070000400003000 ?oho Sign Document ID:U0ZWLKVHFRZWN(38TKJDMPX4XP3PILZV8FDMM26LDW1I SERVICE METER OI O DESIGN s DRAFTINGBY INSTALLATION NOTE E�MENTENERG ENERGY LLC SOLAR PV SYSTEM PHOTOVOLTAIC ; - • • • REVIEW BY J M NABCEP CERTIFIED lSOt.ARBREAKER • ( I ) ALL LABEL SHALL BE INSTALLED IN 051112-129 EQUIPPED WITH • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN 8OPERATING VOLTAGE VDC i REQUIREMENTS. REVISIONS O DE5CRIFTION - DATE REV •" ' (2) ALL LOCATIONS AKE APPROXIMATE AND MAX SYSIEM VOLTAGE VDC 50LAR AC LOAD CENTER - OUT5IDE DONOT RELOCATE TMx O. REQUIRE FIELD VERIFICATION. OWERCtff TDEVICE i (3) LABELS, WAKNING(S) AND MARKING OTURN RAPID SHUTDOWN SWITCH TO Og SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION TO SHUT DOWN 1 1 0.2 1 (13). I PV SYSTEMAND REDUCE SHOCK HAZARD IN THE ARRAY AC DISCONNECT CAUTION (4) THE MATERIAL USED FOR MARKING POWER T THIS SERVICE IS ALSO SUPPLIED FROMFOLLWNG LOCAMDAS ES SHO RH MUST BE WEATHER RESISTANT, IN " DISCONNECTS LOCATED AS SHOWN 50LAR AC LOAD CENTER - IN51DE 2 HY,�ER CONTRACTOR RV BREAKERINT—CAPAGE COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). ® O7 ® I 1 I ARA F-1 (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. ""` SHALL BE LABELED INSTALLED IN I TINSEOUIPMEARFEDBYMULTPLE DUAL POWER SUPPLY COMPLIANCE WITH NEC 690.3 I 7470 50UND AVE I SOURCES T DE RATING of ALL SOURCES:UTILITY GRID �� M ATT I T U C K. N Y I 1952, I OVERCURRENT DEVICES.EXCLUDING I MAIL SUPPLY OVERCURRENT AND PV SOLAR - I LICENSE # 43889-11 DEVICE.SHALL NOT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING AMP"CTTYOFBUSBAR. a.. LICENSE # 52689-ME 30 kWARINNING THIS SERVICE METER ! PROJECT NAME WARNING ! IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD 1 PHOTOVOLTAIC SYSTEM ,I PHOTOVOLTAIC SYSTEM TERMINALS ON THE UNE AND i COMBINER PANEL - - - - - - LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS CONDUIT - OUT5IDE BUILDING -- IN THE OPEN POSITION LU Lu — U � ® ® WW � Q } DUAL P:UTltLljTY UPPLY W L I SOLAR C S STEM ' J Q MAIN SERVICE PANEL - OUT5IDE O � � A CAUTION SOLAR CIRCUIT O A CAUTION _ = LD SOLAR ELEC-RIC SYSTEM CONNECTED O U 0 MAIN SERVICE PANEL - IN51DE POWER SOURCE ' I OUTPUT CONNECTION GO DO NOT RELOCATE THIS 5HEET NAME OVERCURRENT DEVICE pF NEw LABELS �P�P ��Gso�� AC DISCONNECT/BREAKER �o A rrA. e 7f mmmmmmmmmi DRAWING 5CALE 0 0 ® m w W N .T.S . z 703443 Q, ssloNP� 5MEET NUMBER PV-G TAX MAP: 1000070000400003000