Loading...
HomeMy WebLinkAbout15024-zFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y, Certificate Of Occupancy Z15794 Date June I , 1987 THIS CERTIFIES that the building ........ .A.d.d..i.t.i.q n, .............................. 27550 MAIN ROAD CUTCHOGUE Location of Proper House No. Street Hamlet County Tax Map No. 1000 Section 109 . .Block 06 .Lot P/O 00 I/002 Subdivision ............................... Filed Map No ......... Lot No .............. conforms substantially to the Application for Building Permit heretofore filed in this office dated M .ay I 3, I 986 pursuant to whicb Building Permit No. 15024 Z. dated ,J,,u.ne.............,..........25, 1986 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ......... Construct addition to existing library. The certificate is issued to CUTCHOGUE LIBRARY ..................... io¥.'d., 'l d 'a'l 2tg .................... of the aforesaid building. Suffolk County Department of Health Approval ..... .N./.A. ................................. UNDERWRITERS CERTIFICATE NO. N 7987 I 2 PLUMBERS OERTIFICATION DATED: March 12, 1987 Basement is non-habitable, storage only. Handicapped will be improved when front part is done over. Building Inspector TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Y. BUILDIHG P£RFRIT CTHIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) N? ~50~4 Z Date .......... ~.~..J~(.J~. ................................ , Permission is hereby granted to: ....... ...................................... ........ ..~..'CC.H..G.c~.cz ~..,..~.......~.:. ...... .t.Lcj...3..-~' to ..... ~.o.~.~..T,.___~g..c,,T....~....~..~..~..T.L..G~ ...... ~..;O....~.~.,:3.....tt:~Lc~. ....... .~. .. at premises located at....'~.. 7. ~..~"~-'-"~--' ......... J~/...:~..~l....~.~C~,q~, ,. ~L~.L--'~JF~.(~.?.L~/,~t../'~-~r~ County Tax Map No. 1000 Section .... !,...(~....~ ......... Block .,,,(~,,,~('~, ......... Lot No~,O.,,,(~,C~,L,.---~)O pursuant to oppJication dated .....~.....~.~., ....... .~.. ..................... , 19~;;? and approved by the Building Inspector. Fee $ ~ Building Inspector Rev. 6/30/80 FORM NO. 6_ TOWN OF $OUTHOLD Building Department Town Hall Southold, N,Y. 11971 765- 1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY Instructions A. This application must be filled in typewriter OR ink, and submitted ~ ~ to the Building Inspec- tor with the following; for new buildings or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final approval of Health Dept. of water supply and sewerage disposal-(S-9 form or equal). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Commercial buildings, Industrial buildings, Multiple Residences and similar buildings and installa- tions, a certificate of Code compliance from the Architect or Engineer responsible for the building. 5. Submit Planning Board approval of completed site plan requirements where applicable. B. For existing buildings (prior to April 1957), Non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, buildings and unusual natural or topographic featu res. 2. Sworn statement of owner or previous owner as to use, occupancy and condition of buildings. 3. Date of any housing code or safety inspection of buildings or premises, or other pertinent informa- tion required to prepare a certificate. C. Fees: 1. Certificate of occupancy $25.00 -- BUSINESS $50.00 ACCESSORY $10.00 2. Certificate of occupancy on pre-existing dwelling $ 50.00 3. Copy of certificate of occupancy $ 5.00, over 5 years $10.00 4.Vacant Land C.O. $ 20.00 ~, /..4]../, 5.Updated C.O. $ 50.00 Date ....~ .................. NewC°nstructi°n ...... Old or Pre-existing Building ............ Vacan~ [and ............. p y .......... g ....... /.. f6. :,/ ............................. House No. .~ fS~treet I/am/et Owner or Owners of Property .~. ~. Z C ~.~. ~. V~.-LI County Tax Map No. 1000 Section ...i.O.U.. ~ ...... Block ...~ ........ Lot...QP ~.~ Subdivision ............................ ~ed-~o ......... Lo~o .............. Health ~oOt. Aporoval ........................ labor De~t. A~proval ........................ ~equest for Temporar~ Certificate ..................... Final Certificate .... ~ .................. Fee Subm~tte .......................... Construction on above described building an2a~rmit~ets all ~F~able codes and regulati?ns. Applicant....~...~ , .~,'./"'~.,., ..... ~,~ ....... HENRY J. SMITH & SON, PLUMBING, HEATING & FUEL O~L MAIN ROAD SOUTHOLD, N.Y. 11971 (516) 765--3690 ~nc. CERTIFICATION Building Permit No. 15024Z Owner: Cutchogue Library Plumber: Henry J. Smith & Son, Inc. Date March 12, 1987 I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Sworn before me this 12th day of March, 1987. Bernadette L. Taplin Notary Public, Suffolk County State of New York, Commission Expires Sept. 30, 1989. Notary Pub]li6 ~ THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY Dat~ ~pplication No. on file FIXTURE FIXTURES OUTLETS SWITCHES NCANDE$CENT FLUO~E$£ENT 65 54 1,2 29 1.5 10 DRYERS FURNACE FUTURE APPLIANCE FEEDERS RANGES OVENS TIME CLOCKS UNIT HEATERS MULTI-OUTLET SYSTEMS NO. OF FEET DIMMERS SERVICE DISCONNECI~ OTHER APPARATUS: Mo~x)rs: 1-3bp Pa~elbos~ds: 1-15cir. $ E R V I C E 2 AW.G. OF CC, COND 310 2~)Osmps~ 1-7cir. 200stops, 1-7cir. 125eraps 3-5 Ton A.C Units, a- ~tte Cells, 3~,~nc~- ~tes 1-1~ Amp C/B Dls~nn~i; ,~t E ectric Water I~ater: 1-4.5~ ~ox 2A5 Southold, N.Y. 11971 Lic. 5?gE This certiflcote must not be altered in any manner; return to the office of the Board if incorrect, Inspectors may be identified by tl~eir credentials, 765-t8~2 BUILDING DEPT. INSPECTION [ ] FOUNDATION XST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING REMARKS: FINAL DATE / 765-1802 BUILDING DEPT. INSPECTION [ ] FRAMING REMARKS: [ ] FOUNDATION XST [ ] ROUGH PLBG. [ ] FOUNDATION ZND £ ] iNSULATION [ ] FINAL BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING FINAL REMARKS: DATE BUILDING Ds'PT. INSPECTION [ ]~FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL REMARKS: INSPECTOR NOTICE OF INSPECTION COMPLETION SEWAGE DISPOSAL - WATER SUPPLY Job ............... Permit No.., .~..'T,...~..~ ...... ~'~isposal System, Inspection Completed-0K Io r3 inspection Not Completed: ...........................................  Water Supply Inspection Completed -OK to Backfill Inspection Not Completed: ........................................... Dat~,'~.,:c:~,,~.~,~cted by .;~..,,..~.0.,.~,..' .................... SUFFOLK COUNT~' OEpARTMENT OF HF.~LTH SERVICES INSPECTION COMP{.ETION DOES NOT CONSTIYU~E APPROVAL OF INSTALLATION REV(3/85) LATHAM SAND & GRAVEL PRE-CAST CESSPOOLS - SHOVEL LOADERS - BULLDOZERS - CRANES BULKHEADS - JETTIES GRAVEL - FILL - TOP SOIL ORIENT, NEW YORK 11957 516-323-2585 March 17, 1B87 Suffolk County Department of Health Riverhead New York 11901 RE: 0-36, Outchogue Free Library Gentlemen: We have installed a two pool septic eyetem For Glenn F. Heidtmsnn ~ Son, Inc. at the Outchogue Free Librsry, Route 25~ Cutchogus. This two pool deep excavation system consists of one 8' septic tank consisting sf bottom slab, 8' x 8' solid ring with 5' liquid depth and high solid dome; two leach- ing pools each 10' deep x S' diameter with high dome covers; and 6' effective liquid depth. All covers to grade with cast iron castings. Respectfully, LATHAN SANO & gRAVEL, INC. C. atham President CTL/jmj Phone (516) 734.7484 Night [516) 765.1128 GLENN F. HEIDTMANN & SON, !NC. BUILDER COX LANE, CUTCHOGUE, NEW YORK I 1935 MAIL ADDRESS P.O, BOX 632 CUTCHOGUE, N.Y. 11935 To~ Cutchogue.Free Library Main Road Cutchogue, New'York 11935 Date: March 23, 1987 Gentlemen: We are :rob (×) Enclosing ( ) Forwarding under separate cover ( ) Handing you Cutchogue F~..ee L.ibrarynAddition Main Road .cu'tchogue, N~w York ... Copies Dwg. No. Title _O,Tiginal of The New York Board of Fire Under~yiters,., Suffolk Co. Dept. of Health ~~rvices - ~ell Certificate Latham Sand & Gravel - Septic Sy~tem. Cer~if%.cat~ ..... _Henry J. Smith & Son, Inc. Letter Final Inspection has .~een made bY Mr'. Horton of Sou~hold Bldg. Dept, ( ) Approval and distribution Which are for ( ) Yourinfor~atlon Copy of Board of Health ( ) Record Approval of Disposal System & Water Supply Co~ments N798712 Kreiger Well ....x. ~,~,~,~r" Corp. Please initial and return copy Very truly yours, GLENN F. HEIDTMANN & SON INC. By Date F.I ELD~ INSPECTION FOUNDATION COMMERT~ z~ zc FOUNDATION 2. ROUGH FRAME & PLUMBING (2nd) INSULATION PER N. STATE ENERGY ~ODE Y4 FINAL ADDITIONAL COMMENTS: T LD Southold, N.Y. 11971 (516) 765-1938 April 16, 1985 Mr. William Peters P.O. Box 935 Main Road Cutchogue, NY 11935 Re: Cutchogue Library Site Plan Dear Mr. Peters: The following action was taken by the Southold Town Planning Board, Monday, April 15, 1985. ~ RESOLVED that the Southold Town Planning Board approve the site plan of the Cutchogue Library for the construction of an addition on the existing library, plans dated November 28, 1984; subject to a one-year review. If you have any questions, please don't hesitate to contact our office. Very truly yours, BENNETT ORLOWSKI, JR. t CHAIRMAN SOUTHOLD TOWN PLANNING BOARD Building Department By Diane M. Schultze, Secretary Memorandum from.... BUILDING INSPECTORS OFFICE TOWN OF Sou'rHOLD TOWN HALL, SOUTHOLD, N. Y. 11971 765-18O2 . It~go TO WARD ASSOCIATES Landscape Architects, Architects,. Engineers Long Island MacArtht~r Airport 100 Arrival Avenue RONKONKOMA, NY ! 1779 (516) 588-26J~6 Town of Soufhold ~Juilding Department Town Hail Main Street Southold, NY 11971 WE ARE SENDING YOU ~, Attached [] Under separate cover via 5-15-86I 8515 Mr. Edward Hindernann Cutcho,que F~ee Lib;a~y Addltlon BLDG. DEPT, TOWN [Jr ~Ou I'HOLD U.S. MAIL the following'items: [] Shop drawings [] Copy of letter [] Prints [] Plans [3 Samples [] Change order ~ ADDENDUM NO. 1 [] Specifications COPIES DATE NO, DESCRIPTION 3 ADDENDUM NO. '1 THESE ARE TRANSMITTED as checked below: REMARKS. [] For approval ~ For your use [] As requested [] For review and comment [] FOR BIDS DUE [] Approved as submitted [] Approved as noted [] Returned for corrections [] 19 Dear Mr. Hindemann: [] Resubmit [] Submit [] Return copies for approval .copies for distribution corrected prints __ [] PRINTS RETURNED AFTER LOAN TO US The following are the design floor loads used by our structu~'al engineer. loads will be added fo the Contract Drawings as per your request. Roof Desitin Load: 30psf L.L. + 15psf D.L. = 45psf Floor Design Load: 160psf L.L. + lSpsf D.L.: 175psf These COPY TO_ rrng SIGNED: L. FEELEY ADDENDUM NO. 1 For CUTCHOGUE FREE LIBRARY ADDITION AT CUTCHOGUE TOWN OF SOLJTHOLD, SUFFOLK COUNTY, NY Prepared by: WARD ASSOCIATESf P.C. Landscape Architects~ Architects, Engineers 100 Arrival Avenue Ronkonkoma, New York 11779 (516) 588-2626 May 14, 1986 NOTICE TO ALL BIDDERS The Following information is hereby issued and made part of the Contract Documents. All bidders are required to submi~ their proposals after consider- ing the Following changes to the Contract Documents. 8515/AD1-1 ADDENDUM NO. 1 DrawLng No. S-1 - SPECIFICATIONS & SITE PLAN Specification changes General Construction item 14 Delete: "Non corrosive eraydo zinc ties" ... "ff)untoln" Add: "hot dipped galvanized dovetail anchor slots with 1/8" X 1 1/4" wide X 3 1/2" long~ hot dipped galvanized stone anchors?f "foundation" General Construction Item 16 Add: Drawing A-"I 2" General Construction Item 29 Delete: Add: "Cosmic 10E extinguishers with panorama 1038 P42 (two required)" Add: "l_ocate os directed by Architect" General Construction Item 31 Delete: item 31 in ifs entirety General Construction Item 32 Add: (Item e) - Ground (first) floor mirror shall be tilt type to meet ANSI 117.1 regulations General Construction Item 33 Delete: Item 33 in its entirety Drawing A-1 - FIRST FLOOR PLAN Change 3 1/2" /I lally columns carrying laminated beam at lobby fo 3" double extra strong steel columns. Change remaining 3 1/2" ~ lally columns in 4 inch frame walls to 3" ,~ extra strong steel columns. Drawin~ A-2 - FOUNDATION & BASEMENT PLAN Change concrete ~ reinforcement from 6 X 6 I~X 10 to 6 X 6/6 X 6 welded wire mesh. ~ Drawings_A-3, A-4, A-5 & A -6 Contractor to install wood brackets supplied by Owner. Drawing_ A-7 Reinforcing over door number 12 between stairwell and storage room # 3 shall be 3 # 7 reinforcing bars. Drawing A-9 - WALL SECTIONS Alternate foundation wall detail: poured concrete wall w/2 # 5 cont. top and bottom to stone shelf elevation. Install stone facing over hollow load bearing concrete block wlth solid concrete filled cores at all anchor bolts and bearing points] (pilasters, etc.).' Provide # .5 bar dowels at 32'~ o.c. embedded 18" into top of concrete foundation wall continuous in grouted block cores to sill plate. Anchor bolts, fo be 18" long in llfu of 12" long. Provide sheet metal flashing @ stone shelf over continuous waterproofing membrane, similar to bltuthene or nervastral 300 with appropriate adhesives and primers. 851 FI/AD1-2 Drawing A-10 -DETAlLS All details shall have 3-~ diameter bolts at locations shown unless noted otherwise. Detail # 10 - see revised detail # AD-1 attached for typical wood column to steel girder connection. Drawing A-!Z Doors numbered 8, ~, 10 & 12 shall have 14 ga. hollow metal frames welded and prime painted. Marvin window representative - Thomas Stack - 914-647-6100. Hardware schedule - Heading No. 7 - Change doors # 8 from "B" label to "C" label 851 5ZADI-3 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL .... ~r.~c~,.~. ~. PLEASE TAKE NOTICE that your application dated .... ~.Ck(.....~. '. .......... 19~/(.. for pe~it to ....................................... Location of Property cou.,~ z,x Subdivision ....... % ......... Filed Map No ................. Lot No ........... is returned herewith and disapproved on the follow~g grounds . .. ,~q.~zo~, . ,/o~ r,a~ ................ . ~. ~.~,.. ~,'~,, ,~~, :.., ~ ;.~.~ ....... .. ~r ~b.z ~ a~. . ~ . .~ .... ~v~ . d . . . ~.. .~~ . . . . .~~o~.. ~o.: ~... ~..~.(~2.. ~ .... ~. :... .... · .~~.. ~,~..~~.: ........... .............. ....... RV 1/80 from Memorandum BUILDING INSPECTORS OFFICE TOWN OF SOUTItOLD TOWN HALL, BOX 728, SOUTHOLD, N.Y. 11971 7654802 APPEALS BOARD' MEMBERS GERARD P. GOEHRINGERi ¢;NAIRMAN CHARLES GR~GON~S, JR. SERGE DOYEN, JR. ROBERT J. DOUGLASS JOSEPH H, SAW~CKI Southold Town Board o£ Appeals MAIN RE;AD- ;ITATE RnAD 2S I~EIUTHOLD, L.I., N.Y, 11971 TELEPHONE (516) 765-1809 March 1, 1985 Mr. William Peters, President Board of Trustees Cutchogue Free Library P,O. Box 935 Cutchogue, NY 11935 Re: Appeals No. 3315 and 3316 Variance and Special Exception Applications Dear Mr. Peters: Please find enclosed copies of the actions of the Board.of Appeals rendered February 14, 1985, approving the subject applications for the proposed addition. We'have f~rnished copies of same for the Planning Board and the Building Department for their files. The Building Department should be contacted for issuance o~f the building permit and any other approval which may be necessary. ~f yo~ have any questions, please feel free to call at any time. t Yours very truly, Enclosures Copy of. Decisions to .. Building Department Planning Board Suffolk County GERARD P. GOEHRINGER CH&IRMAN ,~ . Planning COmmission P ,D Southold, N.Y. 11971 (516) 765-1938 December 18, 1984 Mr. William Peters Main Road P.O. Box 935 Cutchogue, NY 11935 Re: CutchoguejLibrary site plan ~&r Mr. Peters: Please let this confirm the action of the Southold Town Planning Board, Monday, December 17, 1984. RESOLVED that the Southold Town Planning Board refer the' site'plan for the Cutchogue Library for an addition onto the existing building to the Building Department for certification. Plans dated November 28, 1984. If you have any questions, please don't hesitate to contact our office. Very truly yours, BENNETT ORLOWSKI, JR.~ CHAIRMAN SOUTHOLD TOWN PLANNING BOARD By Diane M. Schultze, Secretary cc: Building Department w/ enc. mAP OF .CuTC./-/O(.~u~ SECTION A NOTICE TO BIDDERS CUTCHOGUE LIBRARY Sealed bids will be received by the Board of Trustees~ Cutchogue Library, Main Road, Cutchogue, New York 11935 until 11:00 a.m. on May 23, 1986 and then at said office the bids will be publicly opened and read aloud for: CU TCHOGUE LIBRARY ADDITION GENERAL CONSTRUCTION INCLUDING PLUMBING, HEATING, VENTILATING AND AIR CONDITIONING, AND ELECTRICAL CONSTRUCTION The Information for Bidders, Form of Bid, Form of Contract, Plans ahd Spfcifications may be had at the Library Office, Main Road, Cutchogue, New York, on April 28, 1986. A deposit of twenty-five i$25.00) dollars, cash or check, made payable to th, "C,:khogue Library", will be required for each copy of the Contract Documents. Any bi'dder returning such set within 30 days from bid opening and in good condition, will be refunded his payment. The Library Board reserves the right to reject any and all bids submitted and to waive any irregularity in the bids submitted or to take any action which they deem most favorable fo the interest of the Library. The Library will not accept bid from, nor award contract to anyone who cannot prove to the satisfaction of the Library Board that he has sufficient experience in this type of work and is flnonclotly able and organized to successfully carry out the work covered by the plans and specifications in the required time. Bidders must satisfy themselves by personal examination of location of the proposed work~ and shall not at any time after submission of bid or proposal, dispute or comp]aln nor assert that there was any misunderstanding in regard to the nature or amount of work to be done. Bid must be addressed to the Library Board and marked "Cutchogue Library Addition% Contract GENERAL CONSTRUCTION INCLUDING PLUMBING, HEATING, VENTILATING AND AIR CONDITIONING, AND ELECTRICAL CONSTRUCTION, and name and address of Contractor submitting bid. SECTION B INSTRUCTIONS TO BIDDERS DOCUMENTS: Complete sets of Bidding Documents will be issued for bidding purposes as stated in the "invitation to Bid". A complete set of Documents consists qf the a. Bound copy of the Contract Specifications/Drawings b. Addenda (if any) PROPOSALS: To be considered, Proposals on the form included herein, must be in accordance with these instructions to Bidders. All bids must be submitted on prescribed fo~ms as bound herein, see Section C. All blank spaces for bid prices must be filled in~ in both words and figures, either typed or in ink. Proposals that contain irregularities of any kind, may constitute sufficient cause for rejection of the bid. In case of any discrepancy in the price or amount bid in the Proposal~ the price, as expressed in words, shall govern. All bids must be submitted in sealed envelopes addressed to: CUTCHOGUE LIBRARY Main Road CutcHogue~ New York 11935 and be clearly identified with: (1) Project Name, (2) Contract and Name, (3) Name of Bidder and address. Proposals shall be signed with name typed below signature. The Bidder's seal, if any~ shall be affixed under the Bidder's signature. Telephone or Telegraphic bids will not be accepted. QUALIFICATIONS OF BIDDERS: The Owner may make such investigations as he deems necessary to determine the qualifications of the Bidder to perform the work, and the Bidder shall furnish information and data for this purpose as may be required. The Owner reserves the right fo reject any bid if the evidence submitted by a Bidder, or the investigation of such Bidder, fails to satisfy the Owner, that such Bidder is properly qualified to carry out obliga- tions of the Contract and to complete the work contemplated therein within the time designated. Fraudulent statements shall cause rejection of Proposal and forfeiture of bid security. CONDITIONS OF WORK: Each Bidder must inform himself fully of conditions relating to the construction and labor under which work will be performed. Failure to do so will not relieve a successful Bidder of his obligation to furnish all material and labor necessary to carry out the provisions of the Contract and to complete the work for the consideration set forth Jn his - Bid. Bidders are cautioned not to submit Proposals until after having inspected the site of the proposed work and having made themselves familiar with local conditions. Attention of persons intending to make Proposals is specifically called to that paragraph of the Contract which debars a Contractor from pleading misunderstanding or deception because of estimates of quantities, 10. character, location, or other conditions surrounding same. Bid shall include the complete costs of furnishing all materials, labor, and equip- ment necessary fo complete the work in accordance with the Drawings and Specifications and ali other expenses incidental thereto. Insofar as possible, any Contractor Jn the carrying out of his work must employ such methods or means as will not cause any interruption of or inter- ference with the work of any other Contractor, or of the proper functioning of the existing facilities of adjacent or contingent properties. ADDENDA AND iNTERPRETATiON: Every request for information of interpretation of Bidding Documents or Drawings must be addressed in writing to Ward Assoclates¢ P.C.¢ 100 Atrlval Avenue~ Rank.rtL.ma, New York 11779~ and fo be given any consideration must be received at least ten (10) days prior fo the date fixed for the opening of bids. Any and all such interpretations, and any supplemental instructions, will be in the form of written Addenda and will be mailed to all prospective Bidders. The failure of any Bidder to receive any such Addenda will not relieve the Bidder'6f any obligation under his Bid os submitted. Any Addenda issued shall become part of the Bidding Documents. Reception of Addenda shall be noted on the "Bid Form". INSURANCE REQUIRED: The successful Bidder will be required to procure and pay for the following types of insurance. Workmen's Compensation. Contractor's Comprehensive Liability ($500,000/$1,000~000) and Property Damage ($100~000/$300,000). Contractor's Comprehensive Automobile Liability ($100~000/$300,000). Fire Insurance - Builder's Risk completed value form (100% of value). FORM OF CONTRACT: Basic forms of agreement shall be the American Institute of Architects "Standard Form of Agreement between Owner and Contractor"~ Document Al01, September 1977 edition, and the "General Conditions of the Contract for Construction", Document A201, April 1976 edition, and all amendments thereto. AWARD: The Contract will be awarded on the basis of the Contractor's experience, bid price, and completion date. SALES TAX EXEMPTION: Under Chapter 513 of the Laws of New York,. 1974, all materials and supplies sold to a contractor and which are to became an integral, component part of a structure, building or real property owned by an exempt organization such as the Cutchogue Library, New York, are exempt from the payment of New York State Sales or compensatory use taxes. Therefore, the Contractor should not include any amount in its bid price to cover sales taxes for the above items. OWNER: Cutchogue Library, Suffolk County, New York B-2 ~ FROM: Contractor Address SECTION C BID PROPOSAL CUTCHOGUE LIBRARY ADDITION TO: Cutchogue Library Board Cutchogue Library Main Road Cutchogue, New York 11935 Att: Cutchogue Library Trustees The undersigned as bidder, declares that the only persons, company, or parties interested in this proposal as principals are named below; that his proposal is made without any connection, directly or indirectly with any other bidder for the same work; that it is in all respects fair and without collusion or fraud, and that no person acting for or employed by the aforementioned Owner is or will be interested directly or indirectly, in the performance of the Contract, or the supplies relating to it, or Jn any portion of the profits thereof; that he has carefully examined the Contract Documents dated April 2.5, 1986, including Bidding Requirements~ Contract Forms, Specifications, Contract Drawings, and Addenda, if any (NOTE: Acknowledgement of Addenda and their Dates must be included as indicated on bottom of page); that he has satisfied himself by personal examination of the site of the porposed work and by such other means as he may have chosen, os to the conditions and requirements of the work; and that he proposes and agrees that if his proposal be accept'ed he will contract to furnish all the ~atrials' and to perform all the work required to construct, perform, and complete for the work for: CUTCHOGUE LIBRARY ADDITION GENERAL CONSTRUCTION INCLUDING PLUMBING, HEATING, VENTILATING & AIR CONDITIONING, AND ELECTRICAL CONSTRUCTION. and all other work in connection therewith, in accordance with the Contract Documents and Addenda, if any, prepared by Ward Associatesf P.C., 100 Arrival Avenue, Ronkonkoma, New York 11779, and complying with all the stipulations contained therein and will furnish the required Performance Bond; that he will complete the work hereunder within days; and that he will accept, in full payment thereof, the following lump sum price, to wit: $ , (written in words) Bidder acknowledges receipt of Addenda as follows: (signature) (signature) And he further agrees that if this proposal shall be accepted by the Owner and that if he shall refuse, fail or neglect to enter into a contract pursuant fo such proposal and to the requirements of the Owner, and shall foil to give the required security within ten (10) days after notice of the acceptance of said proposal, shall have been deposited in the mail addressed to him at the address given in the proposal~ then he shall be considered to have abandoned the contract and the sum represented by the certified check accompanying this proposal shall be forfeited to the Owner as liqui- dated damages; otherwise certified check shall be returned to the bidder within forty- five (45) days after the date of receiving bids. We, the undersigned, further agree that this proposal is a form bid and shall remain in effect for a period of forty-five (45) calendar days from the date of the opening of bids, and that within said period of forty-five (45) days, the Owner will accept or reject this proposal or by mutual agreement may extend this time period. The Following is a list of places where we have performed work of similar character and magnitude, together with references: Location Approximate Cost References The full names and places of residences of all persons and parties interested as principals in the foregoing proposal are as follows: Signature of Bidder: U.S. Treasury No.: Business Telephone: Place of Residence: Date: C CUTCHOGUE FREE LIBRAR Y-~.__~ MA N ROAD · P.O BOX 936 Town of Southold Southold, N.Y 11971 Attn F.J. Murphy, Supervisor February 23, 1987 Dear Mr. Murphy: The (~13~ffl~ff~8~.,~m~;&r~Ei~.e~'t~n~ tripling the size of the library, ~~~~ When complete and furnished in ~t~i~ng, plans a~e to move IO0°A into the Per t i OhS of the r enovat i o n wh i ch ~.~l~e l~gl~:e~;~:~--o.r.:~Co~mmun~i.-tY ......... · ......... ~" "~ ..... *~" '~'~ ~' ~ ' .... and pr. ovision ~or ~ub~.c safety. With ~gard to the remedied in part in that the Extension will have handicap access. With respect to the latter~ ~e~y.~h~;: ~:~.8~~.~i~a~. Although also a pre-existing condition, we ~~F~.~, both morally and legally, ~~~ in this area of the building. Both problems can be handled with the same solution, the a~'~:~~Tji~'~i~7~ opening into the lobby of the present building, with a concrete ramp and railing on the outside, and a panic bar on the door. Full h~ndicap access will be provided and the Town safety code will be met° (See attached sketch.) If a more detailed breakdown is required~ or i~ additional information is required, the Board and library staff are at your disposal. Sincerely, William Peters, President Board of Trustees itF, AI;F' SUFFOLK COUNTY I)EPT. REF. IlO. COMPLF, TION REPORT - 'LONG ISLAND CUTCHOGUE LI BP, ARY X'b'ISIL~ s -- Df~;PARTMENT OF I[EALTII SERVICES s-85269 woil No. _.~OAD CUTCHOGUE LOCATION O~ WELL SAME 5~rlH of WtLL e~;LOW 65 DIA~TE~t 5 I.. ] .60 n. I 21 / CASINGS REMOVED $CREEII$ WELL fl. ft. [ ff. MAK~ ! 5 __. '".1 ,..] ,n.[ C~NGT. 5 ft.] fro I ft. [ ft. D[PHI lo ToP FROM TOP ~ CASI~ Iff. PUMPING TEST ~)ATE TEST O~ PERMANENT PUMPf ~/RATION O~ TEST ~FATIC LEVEL PRIOR TO TIST MAXIMUM ORARDOWt4 lo, below ! LEVEL DURING MAXIMUM P~MPING iff. below top ~ casin6 , ft; [ , top ~ ca~,l~ J Appellate ti~ ~ ~n to nm~t level after cessati~ of ~mpl~ -- PU.P ,.,TALLED ELECTRIC 20 It. DIAMETER USE of w^l~t DOMESTIC COMIq_ETED DROP LImE L/NGfH 40 METtIOO O~ DRILLING C~ lo~afy [~ cable I~l 6/~6 11/86 DAtED~.I.~URILI~ ' JLICENSE NO. 3/1 ~/87 J RRE~G~.R WELL & PUMP CORR j ~o 'N~E: S~ I~ of well - ~terials enc~ntered, wRh de~h ~I~ gr~M wa~er ~ari~ ~s aM waler te~ls in each, casi~s, screens, addili~al p~ping les~s a~ ot~r ~Hers ~ intemst,~scd~ re.ir i~. See Instr<tions as lo Well Drillers' Licenses a~ Repots. Pages 5 - 7. ~ o~ 2 e LO~ Elo ti. ahoy( A TOP of WELL 20 1 SAND & SMALL RI 30 i COARSE AN: MICA 4O 1 50 2 MEDIUM iN1 MUI -~MICA 60 3 MEDIUM 65 '0 WELL YIELD: -- ...................... 2_0__.__G.P.M' CASING: TYPE QF MATERIAL BLACK IRON DROP LINE: TY~E OF MATERIAL PVC IF PLASTiiC, was torque arrestor used? YES 3/16" S.SI, cable installed NO SANITARY SEAL:[ TYPE USED~_ PILTESS ADPATER STORAGE TANKS:i SIZE 251 Inside material BUYTL type of tiank drain BOILER DRAIN GALS,; pressure YES shut-off YES sampling shut-off ivalve with bleeder line installedi' on outflow of tank YES METHOD OF DISINFECTION: CHLORINATION igauge installed ~alve prior to tank i'tap provided YES WELL LATERAL: DEPTH BELOW GRADE 5' MATERIAL WATER TREATMENiT INSTALLED FOR TREATMENT OF 'i MAKE , TYPE I MODEL NUMBER 100# POLY NO TYPE WELL-X-TROL PRINT COMPANY iNAME ADDRESS KREIGER WELL & PUMP CORP PO BOX 101 MATTITUCK 298-4141 TELEPHONE '~ NUMB, LR ACTI6N OF THE ZONING BOARD OF APPEALS Appeal No. 33]6 Application gated December 4~ ]984 TO: Mr. William Peters, President Board of Trustees CUTCHOGUE FREE LIBRARY P.O. Box.9~-5 Cutchogue, NY 11935 (Public Hearing 2/14/85) [Appellant(s)] At a Meeting of the Zoning Board of Appeals held on Febr~ar~.4.~, 1985 the above appeal was considered, and the action indica~-~T0-~ wa~ ~-~ken on your [ ] Request for Variance Due to Lack of Access to Property New York Town Law, Section 280-a [X] Request for Special Exception under the Zoning Ordinance Article III, Section ,100~30(B)[4] [ ] Request for Variance to the Zoning Ordinance Article , Section [ ] Request for Application of'CUTCHOGUE-~FREE-~£~IBR)~R?'~~,'27550 Main Road, Cutchogue, NY for a Special, Excep~'-i-6-~ to..~c~-Zon~.'g~.~!nance, Article III, Section 100-30(B)[4] for permission to establish library use for an addition proposed at premises known as 27550 Main Road, Cutchogue, NY; District 1000, Section 109, Block 06, part of Lot 2 and 1. WHEREAS, the public hearing on the special exception applica-- tion.of the CUTCHOGUE FREE LIBRARY, Appeal No. 3316, was held and conc.luded on February 14~ 98T, a~ which time no opposition was received and the applicant was heard in behalf of this application~ WHEREAS, the board members have viewed and are familiar with the premis~s in question and its surrounding area; and WHEREAS, the board made the followin~ findings of fact: 1. IThe property in question as~'shown 6n site plan dated Novem= ber 28,.1984 contains an area of 31,666 sq.~ ft. and i$]ocated in the "A" Residential and Agricultural Zoning District; 2. The subject premises is improved with an 1800 sq. ft. building which has been and will continue to be used for the Cutchogue Library; 3. The subject premises is bounded on the east by premises presently of the Sacred Heart R.C. Church which is zoned "B-I" General Business, on the south by land presently of Case and others located in the !'A" Residential and.Agricultural Zoning Distrct; 4. This is an application for a Special Exception pursuant Article III, Section lO0-30(B) for permission ~o establish library use within a proposed addition to the presen% library structure; to 5. The project in question has received a variance under Appeal No. 3315, same date hereof, to vary the ~outherly yard setback to 19 feet and the easterly yard setback will be maintained at the established 16 feet, for the proposed 3,580 sq. ft. extension ~.CONTINUED ON PAGE'TWO) DATED: February 28, Form ZB4' (rev. 12/81) 1985. CHAIRMAN, SOUTHOLD TOWN ZONING BOARD OF APPEALS P~Qe ~ - Appeal No. 3316 Ma'tter of CUTCHOGUE FREE LIBRARY Decision Rendered February 14, 1985 of the present library, extending 64 feet to the south and 60 feet at the southerly end at its widest point; 6. For the record it is noted that the January 16, 1985 certification of the Building Inspector indicates that the site plan as proposed before the Planning Board will meet all other zoning requirements, and which this board is in agreement with; In considering this application, the board has determined: (1) that this use of the land in question is not a newly created use since it is an expansion of the present library; (2) that the use will not prevent the orderly and reasonable use of adjacent properties or of properties in adjacent-use districts~ (3) that the safety, health, welfare, comfort, convenience or order of the town will not be adversely affected by the proposed use and its location; (4) that the use will be in harmony with and promote 'the general purposes and intent of the zoning ordinance. In passing upon this application, the board has also considered items (a) through (l) of Article XII~ Section 100-121(C)[2] of the Zoning Code. Accordingly, on motion by Mr. Douglass, seconded by Mr. Sawicki, it was RESOLVED, that a Special Exception for the extension of the propps~d addition to the present library for library us.e BE AND HE~£BY~IS 'APPROV£D'~S'APPLIED~iin the Matter of the ~Q~UTCHO~-O~ RE LI'B~A~', 'A'~'p6~'l N°. 3316~ Location of ~roperty: 27550 Main Road, Cutchogue, NY; County Tax Map Parcel No. 1000-109-06-002 and part of 001. Vote of the Board: Ayes: Messrs. Goehringer, Grigonis, Doyen, Douglass and Sawicki.. This~resolution wa~ adopted by unani- mous of all the members. lk February ~28, 1985 'FORM NO. 1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD~ N.Y. 11971 TEL.: 765-1802 Disapproved a/c .~. ,~.~,~.~ i~.L ~ ~-~,~ .~.tT. .............. ....... .... .... ( ' 'n~s~ectc ) APPLICATION FOR BUILDING PERMIT Received ........... ,19... INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property mnst be drawn on the diagram which is part of this appli- cation. c. The work covered by this application may not be co~nmenced before issuance, of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a'Ce~tificate of Occupancy shall have been granted by the Building Inspector. ,. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Build!ng .!~ermit pursnant to the Building Zone Ordinance.of the Town of Southold, Suffolk County, New York, and other apphcal~} Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections, t~.g~_ ff_.g . .~...,,~. ..... Cs,., r'q4 .o. ................. . . . (Signature of '.a.,pplicant, or name, if a corporatio.n) .. .... (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. Nme of owner of premises ...................................(as on the tax rollX, r-or. latest '~ ............................ deed [~2), ~ ~& '~' If applicant is a corporation, signature of duly authorized officer. ...... .... .............. .......... . (N~ and bfl~ o~ ~o~om~ officer) Plumber's License No.' ( ~..~. Electricians'" ' License No.-..t~ ....,.. ~..~~ ' Other Trade's License No ...................... ' i. location of land on whichproposea work wdl be aerie ..................... / ............................. County Tax Map No. 1000 Section .,.~..(~Y. Block ..~:..~.;.. Lot..~.;.~.. Subdivision Filed Map No ............... Lot ............... (Name) State existing use and occupancy of premises and intended use and occupancy of proposed constroction: a. Existing use and occupancy .... .~./ ............................................................ .~ ~..~.~. b. Intended use and occupancy '~' '/7-- " ~.. k ( ' ppli ) B~ildi ' .. 3. Nature of wor check which a cable: New, ng ....... .. ~. Addition . ~. . ,.~ Alteration .; ...... Repair Removal ' Demolition ' Other Work 4. Estimated Cost .......... I ....... ' .............. Fee .......... , ......... (to be ipaid on filing this application) 5 If dwelling number of dwelling units Number of dwelling unRs on each floor ' If garage, nnmber of cars 6. If business, commercml or m~xed occnpancy, specifE nature and extent Of each type of use .. "? J '.; .... ...... 7. Dimensions qfe~istingstructures, ifany: Front :~...~;/. ..... Rear ~...X,~i~ ...... D~;th Dimensions of Same structure with alt~rations or ad0itions: Front .: ~.~. /. R~r'.~!2111~..e ...... Depth ......... Height ... $..2,:'. ............. Number o Stories ..... 8. Dimensions of entire new constmctmn Front ........ ;'.,..~. 'Rear; .,,. ~. ....... ~... Depth .,.,., ........... Height ............. o' l~um bet of Stories ..... ' ' ' ' · S~ze of lot: Front ..../.~.~, .............. Rear ...~.$ .. !De~th . Nam%qf Former Owner .! .,. Date of Purchase .... f P./. ~. l.~g ....... [~.0 C~ ~'fe' .... ~. . Zone or use district in which premises are situated ....... I.~ ~l~4'~.. :,., ................ Does proposed ...... ordinance or regulation ' construction vmlate any zoning law ..... . ............................ Will lot be regraded ....... .., ........~. ..... ! .... i Will excess fill be removed from premises: Ye~ ~ .No Name of Owner of prgm. ises C .~' ~.C ff.C~.E...L-]~. Address., ....... ~. .....~.. Name of Contractor Address " i Phone No PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and, ~nchcate all set-back dnnensmns from property lines. Give street and block number or description according t9 de6d, and,~ show stree.,t .names and'indicate whether interior or corner lot. ~ · 9. 10. kl. 12.. 13. 14. STATE OF NEW YORK, S.S COUNTY OF ................. (Name of individual signing contract) He is the ............... .., ...... . ...... (Contractor, agent, corporate officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the sa~d work and to make and 'file this application; that all statements contained in this application are true to the best of hi., knowledge and belief; and that the work will be performed in the manner set ibrth in the application filed therewith. Sworn to before me this ....~ ......... /.3 ........ day of ..... .~.4x-~ .......... 19 ~..~ Not~v Public,. ~-'~-~....~....~.,..d'p~'' ....... Count. y.. .~ being duly sworn, deposes and says that he is the applicanf" (Signature of' applicant) 'FORM NO. 1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N.Y. 11971 TEL.: 765-1803 Examined ................ , 19... Received ........... ,19... Approved ................. 19 . .. Permit No ............ Disapproved a/c ..................................... (Building Inspector) APPLICATION FOR BUILDING PERMIT INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli- cation· c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until aCertificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ..... C.~. 'F..e./~.o..&..c,. ~.~ ................ (Signature of applicant, or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, enl~neer, general contractor, electrician, plumber or builder. ............... ~. Crt~v'F ...................................... Name of owner of premises ........................ ('a} ;~' ;~e' ;a'x'r~lf;; ilt;~t' If applicant is a corporation, signature of duly authorized officer. Ok ~ d C~, O/~ ~'c,/'c~6 t,~ (Name and title of corporate officer) Builder s License No .......................... Plumber's License No ......................... Electrician's License No ....................... Other Trade's License No ...................... · Location of land on which proposed work will be done ...... ,,~- /l,r. . .t... ......... / ............................ ...... ............. House Num bet Street Hamlet -- County TaxMapNo. 1000 Section .... ~..(.O..~.. Block...~8i~.: ..q~/.~. .... Lot..4~....(~....'~.... Subdivision ..................................... Filed Mai5' No ............... Lot ............... (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: . s.y a. Existing use and occupancy .............................................................. b. Intended use and occupancy ..... Nature of work (check which applicable): New Building ..... ' ..... Addition i .... Alteration .......... Demolition Other Work Repair .............. Removal ............. Estimated Cost. ~/ 7-'3 .O.! ~ 5. If dwelling, number of dwelling units ............ (Description) Fee .x (to be paid on filing this application) nit ·. Number of dwelling u s on each floor .................. If garage, number of cars .......................................... : ............................. 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use ...... . ......, ...... 7. Dunenslons of e>~lstmg structures, if any: Front... ~..~ ......... Rear ... g.~ ....... Depth .. ~'.~'. ........ Height ... ~ .~ ......... Number of Stories . . .~, ................ ' .................... ~.. . ' Dimensions of same structure with a!ter.aHons or ad0itious' Front ~ .~./ l. Rear ~ 6 6" ~' .... Depth ...... /.I:'. ~t. ........... Height .... .~.2':.t. .............. Number Of Stori;s ..... ./. ~-~. i~ ...... i . 8. Dimensions of entire new construction: Front ............... Rear ....... I ........ Depth ............... Height ............... Number of Stories ...................... 1 ..... ~ ....... . .............. 9. Size of lot: Front .... /.~'j'i .......... Rear .... ~...~.O.t. ~.'.J~ ?'..~.~r..i Der~th t~0' . . . 10. Date of Purchase .... ............... Name of Fo mer Owner i l,i'.O, 1 1. Zone or use district in which premises are situated ........ ~t~i~P~.,9'X'. ~..~. .............. : &'~ i2. ' ' ......... Does proposed construction violate any zoning law, ordinance or regulation' ! ,., I,, . 13. Will lot be regraded ............................ Will excess fill be removed from premises: yes No 14. Nmne of Owner of premises .................... Address .............. i .....Phone No ............. ~.. Name of Architect ........................... Address .............. i .....Phone No ................ Nmne of Contractor .......................... Address .............. i .....Phone No ................ PLOT DIAGRAM Locate clearly and distinctly all buildings, whether existing or proposed, and. indicate all set-back dimensions from property lines. Give street and block number or description according to deed, and sh6w street names and ~ndicate whether interior or corner lot. STATE OF NEW YORK, S.S COUNTY OF ................. ................................................. being duly sworn, deploses (Name of individual signing contract) above named. and says that he is the applicant{: !~ He is the ............................................................................... (Contractor, agent, corporate officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the ~aid work and to make and 'file this application; that all statements contained in this application are true to the best ofhts knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this .~-t~' ....... dayof ...... ~,//.t~ ....... ,19~.~. . Notary Public,...~fi~...~.~ .... .~..~:~.~/...~. .... County",. r--~' --~ ' . - . 8EtENILI~0E .... '~1' ' ' >~'~'V'~'[~ _,.<~ ...................... ~. 4/01,~,. $~a'.~._~"/ ' ~ (Signature of applicant) [i, GENERAL CONSTRUCTION 1. Site Work a. Gontractor to clean and grub site within ccnstruction limlts only. Preserve and retain trees outside these limits. b. Surplus site materials (fill, stumps, etc.) to be removed from site. c. Fill material to be cleon fill and compacted in layers as directed by Professional. d. Con,fac,or in areas of excava,ion and g~oding limits to strip, stockpile and respreod topsoil for use of lawns and plan,ed areas. Controc,or to respreod topsoil at completion of p~oject and seed all dis,urbed areas. e. Contractor to make oil new proposed site grades as indlco,ed, u,ilizing f. Contractor to protect the streets, curbs, sidewalks and other existing items not to be removed. Portions damaged to be repaired to code at Contractor's expense. g. Contractor to protect existing services to remain and to notify all utilities and telephone servlFe and make alrangements for the removal or capping of their equipment as necessary. 2. Concrete - 3000 psi at 28 days ASTM 94 - ready mixed concrete. 3. Steel Bar Reinforcing - deformed steel bars ASTM 615-68. 4. Welded Wi£e Mesh - welded cold drawn steel wire fabric, ASTM A-185. 5. Vapor Barrier - ASTM E-96 Polyethylene film d mm thick. 6. Structural Steel - (lintels, plate, girders, connectors, etc.) to be ASTM A 36 grade, and to comply with AISC standards - shop coat all steel. 7. Lumber a. Douglas Fir - No. 1 grade with Fb = 1500 psi and E = 1,800,000, 19% MC and No. 2 (non bearing) with Fb = 1200 psi min. b. Plywood 1) Subfloor - 32/16, 3/4" th. tongue and groove B-C interior APA with exterior glue. 2) Wa I Sheathing - 32/16, 5/8" th., C-D exterior APA. 3) Roof Sheathing - 24/0, 5/8" th. C-D exter or APA. c. Connectors - Taco Co, or equal, ail to be galvanized. d. Sills - 2" x 8" CCA treated, secured with 1/2" dia. 12" long anchor bolts 6'0" D.C., 1'0" from ends, with a minimum of two (2) bolts per sill piece. Provide polyethylene type sill sealer under sill. 8. Timber - Douglas Fir No. 1 grade. Mortise and tenon const£uction with pegs and angle braces os per details. 9. Roofing - No. 1 Blue Label (royals ~ 24") clear Red Cedar shingles, butt ,hickness and exposure ,o match axis,inc. 10. Siding - clear Red Cedar bevelled siding, 1/2" x 6" applied horizontally with 4" exposure over 15~) building felt. Nails to be hot dipped galvanized. l h Fascia and Wood Trim - clear Cedar, frieze, 3/4" x 4" tongue and groove clear Cedar strips. Belt course ex 5/4 x 10" clear Cedar with chamfered edges. t2. Soffits - 5/8" th. A/C, tongue ~and groove, Fir exterior plywood. 13. Soffit Vent ~ contlnuous 2" wide extruded aluminum section with baked enamel finish (white). 14. S,one Veneer - squared stone approximately 5" x 11 I/2" ,o match existing. Held back with non corrosive eroydo zinc ,les embedded in foun,ain wall, 2 1/2 s.f. maximum area per tie. Mortar joint size to match existing. Stone shall be set in non staining cement - lime mortar. 15. Flashing - flashing to be 16 oz. lead coated copper. 16. Doors, Windows and Hardware - see schedule drawing A. 17. Door and Window Trim a. Exterior - 5/4" x 4" clear Cedar, corners to be mitred. b. Interior clear Pine, profiles as per drawings. lC. Insulation - fiberglass with foil faced vapor barrier by Owens. a. 9" - between rafters (vent space over) b. 6" between studs on g~ound floor c. 3 1/2" - between metal studs in basement walls d. 9" - above suspended ceiling in basement e. 9" between floor joists over crowlspace 19. Gratings - steel bearing and cross bars with I 3/16" x 4" openings. Hinged with PLUMBING 10. I1. 12. 13. 14. 15. 16. 17. General Furnish o!ll labor, materials, equipment, plant, tools, and services necessary and requilred for proper and complete installation of ali Plumbing System and related work, to include but not be limited to, water supply and distribution piping, drainage piping, plumbing fixtures, valves, traps, waste and vent piping, including all their respective connections, devices, appurtenances withlln the building lines of the premises. Plumbing fixtures to include, but not be limi,ed to lavatories, sinks, water heaters, etc. Codes - All work stholl conform to the requirements of the New York State Uniform Fire Prevention 8uiilding Code and the Suffolk County Department of Health. Piping - Cold and Hot Water, Type L Copper tubing (ANSI H23.1) with solder type fittings and joints rmade with 75/5 softmetal solder. Below ground piping to be Type K Copper tubing. Risers and mains to be 3/4 inch, ail branch lines to fixtures to be 1/2 ~nch. Water Service - Underground water service piping to be 1 1/4 inch, 160 lb. test plastic. Drainage and Vent Piping - Above ground drainage and vent piping to be cost iron and galvanized. Sanitary Pip ng - Below ground sanitary p p ng shall be cast iron soil pipe (ASTM-A-74) service weight, and PVC pipe, be and sp got extra strength ASTM 3034), (Class 2400). Flashing Flashing ma,erlals to be lead 4 lb./sq, ft. Hose Bibbs - Hose blbbs to be nomfreeze type with interior shut-off valve. Plumbing Fixtures - Furnish and install the following as manufactured by American Standard, Inc.: Bathroom Fixtures - a. Two Cadet Elongated Toilets - one t~ 2109.405 and one t~ 2108.408. b. One Comrade Lavatory - tt 0124-024 - color to be selected. c. One set Cadet Lavatory Faucet I~ 2350.049 with cast grid drain. d. One Wheelchalir Lavatory - ~ 9141.011,, wall hung with 2103.786 Heritage Centerset fau¢cet with cast grid drain and concealed carrier bolted to floor. e. One Slop Sink and Fittings in Mechanical Room. Valves - Valves to, be brass/bronze body - 125 pslg. Cieanouts - Cleamouts to be full size of pipe with threaded brass screw plugs. Plates Plates fort finished spaces to be chrome plated split brass. Pipe insulation - Pnlpe insulation to be cellular foam of thickness required by Energy Code. Water Heaters VWater heaters to be electric. One (1) 10 Gallon and one (1) 30 Gallon. Sears ~Power Miser ar equal. Water System ~ lnstall a new pressure water system including a 52 gabon equivalent rated glass lined tank (American Granby or equal), 3/4 H,P.~ 20 gpm submersible pump, controls, piping, etc., necessary for a complete system utilizing a newly installed 5-1nch well. Contractor shall provide high point vents and low point drains. Sanitary System - Install sanitary system including excavation, backfill, trenching, precasr septic tank, drainage basins, complete with extensions to ground surface amd cast iron cove£s; new 4" sanitary line at grade inverts indicated from buJi]ding to septic tank, and interconnecting pipe. Backfill to be approved by S~uffolk County Health Department. HEATING, VENTILATING AND AIR CONDITIONING 20. 21. ANSI A42-4. 22.. Suspended Ceiling - acoustical ceiling shall be non-combustible mineral fiber board by A£mstrong War d lndustr es type - Second Look IV f~ 2790, 24" x 48" x r 3/4", lay-ln. Suspension system shall be standard type, installed in accordance with ASTM C 63,$. 23. Gypsum Board a. 1/2" thick, taped and spackled in compliance SA-216 "Application and Finish ng of Gypsum Board' by the gypsum association. All outside corners to have metal corner beads. b. Mechanical Room - two (2) layers, 5/8", type "X", walls and ceiling. c. Storage Room - one (1) layer, 5/8", type "X", walls and ceiling. 24. Wall Base a. Basement - vinyl b. Ground Floor - clear Pine, as detailed on drawings. 25. Painting a. Exter or · · ts /'~ 1) Corner boards/trim/fascia, soffits, Jrieze and belt - two (2) coo ,f'') solid white stain by Cabots. / 2) Wood siding - two (2) coats Cabots ~leaching s~a~n. " ' t '~ 3) Doors and Windows - one (1) coat primer, two [2/ coats wrote pain Interior ,, )Walls - one 1 coat sealer, two (2) coats flat B. Moore, or approved equal. Color to be selected. 2) All Woodwork - one (1) coat sealer, one (1) coat stain, two (2) coats satin polyurethane finish - B. Moore, or approved equal. 26. Dumbwaiter - furnish and install model ~! F 500, floor loading, electric dumbwaiter, series "F", with slide up door~ as manufactured by the Atlas Elevator Co., Chicago, Illinois. 27. Kitchen Unit - NIC 28. Depositary Un t - furnish and install book depository unit model ~ 61550 as manufactured by the Mosler Depository Carp., Grandview, MO. 29. Fire Extinguishers - multi-use, dry chemical type, in cabinet similar to H-10 by J.L. Industries, to comply with N.F.P.A. 10, latest edition and local fire codes. 30.Flooring o. General b. Mechanical/Storage Rooms - vinyl composition tiles adhered to slab with manufacturers approved adhesive. c. Bathrooms - 2" x 2" mosaic tile with caved base, installed in accordance with manufacturers specifications. Tile to be selected. 31. Bathroom Fixtures - furnish and install the fallowing, as manufactured by American Standard Inc. ' a. Two Cadet elongated toilets t} 2109.405 ~ :a,Z~O~ c. Two sets Cadet lavatory faucets f~ 235D.015 Or~ c~t- +m I~ave d. One slop sink and fitting in mechan ca!iroom. 32. Bathroom Accessor es - furnish and install 'ihe following: a. Two grab ba~s, length and location indicated on drawings (ground floor), to meet ANSI AI17.1 standards. b. Two continuous flow toilet paper dispe~sers by Bobrick~ or approved equal. c. Two paper towel dispensers by Bobrick., d. One sanitary napkin dispenser by Bobrick. e. Two plate glass mirrors, 2'0" wide x 1'3" H., in brushed stainless steel frame with concealed attachment. NOTE: Installation in ground floor bathroom to comply with Federdl Registe~ Handicap Regulations, Section t~ 1190.150, and ANSI A 117.1. 33. Steel Stairs - furnish and install steel pan 1ype stairs with concrete filled treads, including all stringers, ballisters, bars, angles, channels and rods per drawings. Structural steel to conform with ASTM A36. Stairs shall support a superimposed load of 100 pounds per sq. ft. Paint finish. ~.Chimney - brick masonry construct[on with g" clay flue lining. Provide c.L cleanout door in mechanical room, all to meet fi~e code requirements. 35. Access Door - furnish and install 24" x 36" hinged steel access door between storage room and crawl space. two (2) heavy flush type hinges by Borden Metal Products Co., or approved equal. Hand Rails -a~ d~o,led o~..drowlncj~ Monugccfur~r eh~ll be, Jul~u~ ~[um ~co, In6 Steel Stud Framing - 3 5/8 steel stud framing system, 20 ga. to comply with GENERAL NOTES h All work to be done in accordance with New York State Uniform Fire Prevention and Building and Energy Codes'and those of any local governing authority. 2. All concrete work to be done in compliance with the building code requirements for reinforced concrete ACI 318-77 and local building codes. 3. Structural steel shall comply to specifications for design, fabrication and construction of steel for buildings of the A.I.S.C. 4. Ali framing and connections shall be in accordance with the latest edition of the National Design Specifications for Stress Graded Lumber and its Fastenings as published by the N.F.P.A. 5. Contractor shah verify all dimensions and conditions prior to construction, and report any discrepancies to Architect befme proceeding with work. 6. Dimensions on plans are shown to studs. 7. Contractor will obtain all required approvals, permits, certificate of occupancy and inspection approvals. 8. All materials shall be installed in strict accordance with manufacturers specifications. 9. Drawing not to be scaled. 10. Provide exhaust fan in basement, bathroom. t 1. Proposed sanitary system shall meet all requirements and standards of Suffolk County Department of Health Services. l. General -'Furnishl all labor, materials, equipment, plant, tools, and services necessary and req~uired for proper and complete installation of ali Heating, Ventilating and Adr Conditioning Systems and related work. HVAC Systems will include, but not be limited to, installation of oil Fired boiler, air handling, venting, duct work, and ali system related piping, valvlng, controls (electrical control wiring), amd ali necessary devices for complete fully operating system as layed out on tlhe appropriate drawings. Demolition and removal of ex[sting heating system, flue, et.al, in existing building to be included in work scope to accommodate new system. 2. Codes All work: shall conform to the requirements of the New York State Uniform Fire Prevention Building Code and the Suffolk County Department af HeaLth. 3. Heating and Coaling System - Heating and cooling system to be a three (3) zone system, each with its own air handling unit, hot water, and DX coils, its own air handling unit and controls as shown on the applicable drawings. Zone ii 1 - New Library, Lobby and Office (heating and air conditioning). Zone ¢~t 2 - Basement and Storage (heating and air conditioning). Zone il 3 - Existing Library (heating only). 4. Bailer - Boiler to be Well McLain, P 766E, 205,000 BTU/Hr. 5. Circulator CircuJator~ one for each zone, to be B & G, Series 100, sized for appropriate gpm with settable flow check. Pipe size 1 1/2 inch, Type L insulated in accordance with New York State Energy Code. Seals to be suitable for glycol solution. 6. Fan Call Units - Fan call units complete with housing, blower unit, 110v configured for system shown on drawings and with ARI noise rating less than 8.0. Split system condensors to be designed for outdoor installation, concrete pad mounte~, twin fan, double coil, and energy saving compressor. System to be Carrier, Series 39B, York Champion V, or Rheem floor mounted units with top discharge. Zone 1: (Ist ilo.or) Air Handier (Discharge Position V) 3200 cfm (Carrier 39B060) Cooling Coill DX 79,000 BTU/Hr. Condensor 8 Tons H W Coil -~ 100,000 BTU/Hr. Zone 2: (Basement/Starage) Air Handier 130(] cfm (Rheem RH-QA-12) Cooling Coil - 21~000 BTU/Hr. Condensor 2 Tons H W Coil - 18,000 BTU/Hr. Zone 3: (Existing Library) Air Handler - 1600 cfm (Rheem RH-QA 16) H W Co~l - 80,000 BTU/Hr. (Not to be ]ncluded in base bid - provisions for Cooling Cofll - 46,000 BTU/Hr. 7. Thermostats - T'hermos,ots to be Heating/Cooling, Day/Night set bock equal to White Rogers. 8. Duct Work - Du~c, work to be fabricated in accordance with SMACNA Standards including transittlons, bends, take offs, etc, designed for minimum static losses. Duct m(aterial to be galvanized sheet metal af 26 gauge up to 24 inches wide, and 24 galuge above 24 inches wide. Seams and ioints shall be such that leakage is not nnore than 3%. Ducts shall have rigid fiberglass acoustical and thermal liners, '1 inch thick for supply and 1/2 inch for return. Wrap duct work in unheated spaces with insuJa,ion. 9. Filters Filters shall be Space-Gard, model 2200, high efficiency units. Eight inch deep pleated units, rated at ~9% efficient with 6 micron size particles. 10. Humidifiers - Humidifiers to be an integra] part of unit atomizers, spray type, with humid~stahs. Zone f~ 1 only. 11 Diffusers 5upmly diffusers to be Hart and Coo ey or equal with adjustable opposed blade d~[ampers, adjustable discharge vanes and enamel finished trim. (See Drawings.) 12. Return Grilles Return grilles to be Hart and Cooley or equal with adjustable opposed blade dampers and enamel finished trim. (See Drawings.) 13. Underground Fuel Tank - Fuel tank to be double wall fiberglass as manufactured by Cardinal. T~nk to be round 550 gallon tank and installation to be that approved in accordance with provisions of Article 12 of the Suffolk County Sonit ary Code. 14. Control Wiring All control wiring to be by HVAC Contractor. Line voltage wiring by Electrical Contractor. 15. Duct Wo~k D~ct work to be installed to be free from vibration, and supported on maximum g ft. center. Duct joints shall be properly sealed 1 inch on each side of joints. Exposed duct work shall be galvanized steel 16. Volume Dampe~ Provide volume damper, or other approved air balancing device, with indicating and locking quadrant whether or not shown on drawings, at each form main ductb at each duct take off, and at each neck to individual diffuser or register in stupply, return or exhaust ducts. 17. Back Draft Darmpers Back draft dampers shall be instal[ed where indicated on drawings. 18, Fire Dampers -- Provide ~ppro~ed fire dampers rated 2 hours, or to match fire rating of wall. 19. Acess Doors - IProvide access doors as required for coils, fire dampers, filters, dampers, and o~ther equipment that require periodic service. Doors shall be of the same mote~rials as the duct work, and constructed so as to minimize leakage. 20. Ventilation Sysstem - Gable vent to be a DynaMaster model FQ14F4, 1.3 H.P., 2 speed exhaust tfan rated at 2,000 c.f.m, at .250". Unit to be equipped with automatic air cdamper, wall collar and bird screen. Ceiling shutters to be motorized lO0w., with coating to match ceiling. Exhaust fans and shutters to be interlocked wltlh air conditioning system so that both cannot be operated simultaneously.. (Option - provide separate price.) 21. Heating and A~ir Conditioning System Heating and air conditioning system shal' be complete w}ith oh necessary components and items normally supplied. Substitutions o~f equipment shall be approved by the architect/engineer. System operational ch~eck-out~ balancing, including demonstration to Owner. All appropriate opeerationo~- an6 maintenance manuals shah be provided. 22. Completion JAt the compietlan of the work all equipmen, complete with their fittings shall b0e properly cleaned out, tested, and left in first class working condition. Alii duct work shall be left clean to prevent system dlstH~ution of dust and dirt. System shall be left with clean filters. 5O2 ELECTRICAL I. General Furnish all labor, materials, equipment, plant, tools, and services necessary and required for proper and complete installation of all Elect£ical Systems and related work to include~ but not limited to, wiring, lighting, services, feeders, distribution and protection equipment, connections of appliances, grounding, and including all connections and devices within the scope of work as shown on the applicable drawings and as normally specified in this type of project. 2. Codes All work shall conform to the requirements of the New York State Uniform Fire Prevention Building Code, New York State Conservation Construction Code, and the National Electric Code NFPA 70-1~84 (NEC). 3. Load Panelboard Centers - Load panelboard centers shall be plug-on type construction. All current carrying parts of the bus assembly shall be plated. Terminals for feeder conductors to mains and branch neutral shall be UL listed as sultabie for the type conductor specified. The load center bus assembly shall be enclosed in a steel cabinet. The size of the wiring gutters and gauge steel shall be in accordance with UL standards No. 67 and 50. Fronts shall include door and flush tumbler type lock with all panels keyed alike. 4. Panelboards - Panelboards shall be equipped with quick-make, quick-break, thermal-magnet trip indicating, and have common trip on all multipole breakers. Trip indications shall be clearly shown by the breaker handle taking position between ON and OFF when the breaker is tripped. Trip ratings os indicated on the plans. Breakers shah be plug-on type. Branch circuit breakers feeding convenience outlets shah hove sensitive instantaneous trip sellings of not more than 10 times the trip rating of the breaker to p~event repeated arcing shorts resu]tlng from frayed appliance cord. 5. Circuit Breakers - Single pole 15 and 20 ampers circuit breakers shall be UL listed as Switch ng Breakers at 120 V a.c. and carry the SWD markings. Circuit breakers shall be UL listed. Single pole breakers with handle ties nnot acceptable. 6. Ground Rods Ground rods shall be 5/8" x. 8' copper weld and meet all requirements of the applicable provisions of the NEC. 7. Cable and Wiring - a. Branch Circuits (Interior) - Type NM or NMB. b. Service Eh,ronco (Direct Burial) - Type USE. c. Feeders Type NM, NMB, or SEC. d. Underground Distribution (Direct Burial) - Type UF. e. Conductors to be copper unless indicated !'AL". f, Insulation (600 vol,) ~ ]0 AWG and smaller~ - THWN/THHN~ ~! 8 SWG and larger - THN, THWN, XHHW (PVC for NM or UF cables). g. Neutral wire shall hove a white outer covering throughout system. Equipmen, ground wire shall have o green au,er covering ,hroughou, s~ystem. Mark cables or wire withou, color coded jackets with nomfadlng colo~r coded tape a, terminations and other accessible locations. 8. Raceway - Raceway to be rigid or metal conduit or Schedule 40 PVC (whcere permitted by Code). 9. Outlet Boxes - Outlet boxes dry concealed locations in wood frame construction ' to be PVC wall boxes and noryl ceiling boxes. In exposed lo,cations, use 4," square cast aluminum boxes and finished covers. 10. Sw)tches Sw tche~ pressure-sensffive type, 15 amp. 120/277 volt, back olnd side wired. Single po]e~,,double pole, three way dimmer, as required. 11. Duplex Receptacles Provide 15 amp 125 vo~t back and side wired duple~ receptacles on all muitl-receptocie 15 and 20 ampere circuits. Provide 20 amp 125 volt bock ~nd side wired duplex receptacle on all single receptacle 20~ ampere clrcuffs. Ground fault circuit interrupting - 20 amp 125 volt wlth~ indicator. 12. Plates Provide plates for oil outlet boxes (receptacle, switch, telephone, blank or comb[nation). Smooth plastic urea (ivory color) unless indicated otherwise. Multi gang switches, receptacles, etc. shall be in a common, one-piece plate. 13. Lighting Fixtures - Lighting Fixtures: see schedule on drawings, supplied by Spectra Lume, Inc. Lighting fixtures to be approved by Owner prior to purchase. D. Surface Mounted Flourescent - Lithonia 2 tube - 4-foot - tt LB 240 A - 120 EF J. Eyeball Incandescent Lit.honia tt LP-RE2-120 LOCATION MAP / / / / / / / LIST OF DRAWINGS ~-1 Specifications and Site Plan A 1 First Floor Plan A-2 Foundation/Basement Plan A-3 West Elevation A-4 North Elevation A-5 East Elevation A-6 South Elevation A-7 Building Sections A-8 Building Section A-9 Wall Sections A-10 Details A 11 Details A 12 Schedules P-1 Plumbing Plan and F~iser Diagram P 2 Site Plan and Profit, Sani,ory Waste H-1 HVAC First FLoor Plans and Sections H 2 HVAC Basement Plans and Sections E-1 First Floor Electrical E-2 Basement Electrical SITE PLAN FEE~ BY: NOTIFY 'BUILDING DEPAR'I~ENT AT 765-/802 9 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: ~]. FOUNDATION - ~O REQUIRED FOR POURED CONCRETE ~ ROUGH - FRAMING & PLUMBING ~. INSULATION 4. FINAL - CON'STRUCTION MU~ BE COMPLETE FOR C.O. ~LL CONSTRUCTION SHALL THE REQUIREMENTS OF THE N.Y, ~TE CONSTRUCTION & ENERGY ~DE& NOT RESPONSIBLE FOR ~tGN OR CONSTRUCTION ERRORS. project tltle: CIJTCHOGUE FREE LIBRARY drawing .SPECIFICATIONS! AND SITE PLAN drawn by: checked by: .da~e: scale: drawlno number: S'1 1 ret no.: IOLO' © I I ~ O, I~AMIa 4 PLAN 7L%" projeot fit!e: CUTCHOOU AO~21TIOf~ drawing title: PLAN d[~.w/n ~,,~ cheokedM.,l¢ by: date: 4. 8¢0:. ¢,G scale: drawing cumber: A1 OF reft no.: NA~B~*? SUFFOLK BLUEPRINTING J ~ L___J .I F __1 kl'rcHe.~ uNrr (N,:.cb t JI MOT~' ~ I2OZ::~ i WINDOW PLAN project title: drawing title: ~::)LIN DATION / ¢;~KS[Nde. NT t~LAN drawn by: checked by: ~p/I~l~, date:-~, ~5.80 scale: 14./MILO": drawing number: ref, ,]o4' ' ,4~ ,~,,,'[5 : ? WP~ST ELP__.VATI OH ~.y,I~T I1'4 0 ~UILr21HO /£, HANI2?.AIL. pFOject title: C UTJHO~U~ L..ttD I~AK¥ AIgF21TION drawing title: drawn by: checked by: ~-/~,~, b,~ dete 4.Z5.~ sc~le: t,411=~l-OI drawing number: OF NORTH I~LF_.VATIONt EL ',~.4S'T'INC, Al' L~r~CF::~SCf~) project title: drawing title: NOF. TH ~L~VA'TION drawn by: ~P/~e date, checked by: scale: I~II~ILo" drawing number: NASSAU SUFFOLK BLUEPRINTING EAST P____.. L ¢__..VA'T I 0 N FF-,W OGI'4 STR UCl'l Olt project title: CUTCHOOUff. _ LI~RA~y' A~r2 ITlOh4 drawing title: P_Ab-'T ~L~¥ATION OF WOOD ~HINGL~ ~ pro~ecf title: CH¥CHO~UE bi drawing title: SOI_]'FH P-.LF-VATION drawn by: checked by: date: 4. ~5.~, scale: drawing number: A6 OF ret. no.: ' k DJILO1HG (DULL ~21I"t G drawn by: checked by: date: drawing number: scale: OF I I drawing title: OF J[ J 't J , project title: CLJ'T'C HOGU5 ADDITION drawing title: WALL SP--CTIO'H$ drawn by: checked by: date: 4.75. 5(~ scale: drawing number: A OF 10 t u ,i. p jeCf rc t fie: ,: .. '. dr~w no title: ' drawn by: date: 4.~,~ scale: drawing number:' A OF ~2 ~IK~T ;FLOOt< $'TAI~ 'PLAN PLAN / F ~'TAII~. SECTION ~H~ ~tP F'IN~GH FIt,L, 8TAll'< SECTION ILO" proJeot title: " cLrrcHoc;,y~. ,AP,r) TION drawling title: drawp by:. I~/'~,~' date: d,?%~,, Checked by: drawing number: , , /et. n6,: ' O0O S 1 HARDWARE to ordering any hardware items. . . 2. A hardware sh~ll be of a type which can I~e opera+ed ay rne p~nyslcauy handicapped (ANSI Al17) -, 3 Butts on ogJ. swinging exterior doo~s shall ~oye non-re~ova?~p~ ~, -, ' ~. -., ' ' re~for d~rs l~ading tb~h~dous' spac~u~he~s m~chuqlcal rooms s~a[~,,, 4. Entry hardwa · ' 7 be knurled' to prev~t accidehta~ entry by hand~cappe~er'soDs~(A~,A~).)..~ 5. K, eying shaQ be as directed by Owner. Provide th(ee ~/keys per (3) master keys. 6. All hardware to have dull brass finish. FINISH HARDWARE ~aldw~h Hinges Baldwin hocksets Corbin , Cylinders LCN Closers Baldwin Push & Pull Plates Baldwin KJckplates Stops, Holders, Silencers~ ~umpe~s Ba[dwln Thresholds & Wealherstrip Zero Lurid Key Cabinet Van DupHn Exit Devices 'HARDWARE SCHEDULE ~[T~cK door liste~er each heading is to receive all the Items listed under . that heading. NOTE: There is more than one door per number, Verify q~antity by reviewing drawings. b. For any doors which may be indicated on the drawings but not mentioned in the "Hardware Schedule" listed he:einafter~ hardware of~ the same type quaUty and funcHoh as that scheduled for similar proposed doors shall be provided. HEADING NO. 1 Doors # 1 - Exterior from Vestibule - Exterior from Stack Space # 1051/10~0 4 1/2 x 4 1/2 x 3 pr. butts 2 push/putt # 2110/2600 2 push plates # 2110 2 cylinders Corbin # 5283 1 extension bolt/strike # 0600 2 closers .4041 4 kickplates 12" bt. 2 saddles # 656 2 floor bumpers . # 4010 HD 8, jamb wth~strip # 316 sill wthrstrip # 3? meeting stile wthrstrip tf 328-M HEADING NO, 2 Door # 2 - Vestibule from Lobby Door # 4 - Existing Library from Lobby 3 pr. butts 1051/10Y0 4 1]2 x 4~ ¥2 2 push/pull 2 push plates 2 closers 4 klckplates. 2 floor bumpers US4 US4 US4 US4 US4 DBL US4 US4 Bronze US4 2110/2600 US4 US4 2110 DBL 4041 12" ht. US4 US4 '4010 HEADING NO. '!3 ' · Doo£ # 5 - Exterior from Hall '~:'" , # 8636 ,~,.,~, ,.,~ _ ,, ',- >,-,, - ,1 mortise cyffnder Catkin ~528~ , :~12" h~. ,' ,,,. ,,r: '1 kickplafe ' z ':., ,, ..... HD & jamb wthrstrip #'316 .u , . , -, - ' ' ' ~' "': US~ ~lll wt~strip 'L ' "~,'i ~ 3~ ,. ~ . , '~ze,: ] floo~ bumper -,' '#40,10 HEADING NO, 4 ~ ' Doors # 6 - Lobby to Office ' 1/2 pc. butts - !' ' 105 / 0.90 1 1/2 pr. butts 1 lockset lcldser 1 kickplate 1 floor bumper 3 silencers 1 lockset" 1 floor burnpe~ 3 silencers HEADING NO. 5 Door # 11 ~ Hall to ~ol[~t - Storage' i'D Toilet 1051/10~ 863~ (privacy ¢,~ctl0n):. ~r 4041 ' ' 12" hi.I r ' #'4010 863~ ' " ~ ,' Co~bln ~f 5283 , :, .',:, :.~ 401'0 HEADING' NO. 6 Dooms # 7 -Hall~o Closet -,l . - Office to Closet . ,.~ - '1 1/2 pr butts 105.1/1070 . ' '" "': [ :}~" i 1 latchset ,863~ (sfore-r0om funct an),e, i' 1 cylinder Co~bln (hall dogr~onl'y) tf 5283 ~, 3 silencers HEADING NO. 7 ~ US4" . Dg~' ', ' US4 " · U$4 ' DBL US4 U~4 ' ,~U ..... u, s4 , Do'rs # 0- Storage if 3 ~o Stora,e Room~# 2 - Storage # 3 to'Storage Room # 1. B; Lobe{, I 1/2 p~. b~tts 1051/1090 4 ]~2 x 4 ]~ . 1 lockset 8636 1 cylinder ¢ Corbln-# 5283 "r I 1 closer 4041 , - DBL I floor bumper 4010' . 3 silencers ' ' : r H~DING NO. 8 ' ' ~"' ~ " :"' Deer # ~ - 5to~age # 3 ~o Mec~an cai Eq'u pmeQt I 1/2 p.. 5utfs ' 1.051/10~0 ~lJ~ 1 logEse f · 1 c~llnder , 1 closer HEAD~NG~NO, ~ ]Door #~ 12 - Stair Hall [r~ S~orage ~ 3., ' S pr. butts - '1051/10~0 '1./2 2 push/p~ll plates 21 i~/2'~00 ' 2110"" : .. .. . .: , . ?US4 " 404! ~ ~ '', '. I ,,, ,~.. ,' ' DBL 4010 : ':" ~ ' :,:' U~ 8636 , US4 Corbin # 5283 ~ ' ; US4 :' ' '" · ' DBL 4010 ," ' ' US4 Us4. . ', , US4' p,roJecttltle: dtawing title: "" drawn by: checkedI by: ()=/~ k~ ,, date: 4.2~.~> scale: drawing number: A 12 OF ref, no: ~blO // / // // // // / ! 4~CL£AAIOUT -~ I // ./ If copper tubing is used for water distributing system; piping sbaj| be o[ types K or L only $OLD~ t]~ED IN WATER ~UPPLY SYSTEM CANNO~ PLUMBER CERTIFICATION' ON LEAD CONTENT BEFOR~ CERTIFiG~TE OF OCGUPA2iC~' ptoJeof ~e: ,¸'% + ~7 drawing title: ' I · ' drawn 'by: ¢./,4. ,~.~' date: scale: drbwlng ~mbed OF tel po,: ': , ',:. 1' Prior 0 . ' - ' ' " r ~ more sha~l revtew all dra~ : ,, , f~n~she~L gypsum [,'i , ' E: ' r ,routed',~ nd ,Z/Nb 77o ret r~o, '4 ~L ' ' drawn by,: date: ~ ' , drawing ~Hmlz~r:., % ~ r 1-1 vo (rYp) l~x 4UP ~oT. ,i2 x (,, '24 x r t ~0~ (~ ,' d~awn, by: ch~:~ked by: date; · ' i d~w,lng numJ:~r: - -, ' ' t, r. ef, nO.:, ¢515 I PIX T'UI~E 5CN E-DULE- ALL 12_OOPl ~E-C,~-p"'ACL~-~ { VACOUr40dTLE:T5 tO BE- C.~_h,JT~'~'.~..E~ OM J k CD ~t~Or. p' 2 ri:{-L SAS~Sc SDS~S~F SGS~ST I ,7 ® I i© .dY DE-TAIL OF- S\VITCt-I PANEL drawing tltle~ drown by:'; I checked by: U,'IP date' seal,e: drawlr~g~pumber:. ... OF ~) re¢ no £ ]l ,/ I00 A~'IR, A,C. PAIqFL- ~0 CI~c©IT'~ ""--- L% 51i',IGLD pro eot fit e~ . drawing title; ' '~' drawn by: ?, checked by: , LMt=, drawing J~. 0 ,,iml OF 0 ~ref. no: .8,~15