Loading...
HomeMy WebLinkAbout16606-zFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. Certificate Of Occupancy No. g17503 Date November 10, 1988 THIS CERTIFIES that the building ONE FAMILY DWELL ING Location of Property .. 56985 C,.R. #48 GREENPORT House No. ........... 'S't/e~ .................. Hamlet County Tax IvIap No. 1000 Section . . .0,4.4. ...... Block 0 I .... Lot 2 9 Subdivision ............................... Filed Map No ......... ]Lot No .............. conforms substantially to the Application for Building Permit heretofore filed in this office dated .... I~0.V., . 6 .... t9t~7. ·. pursuant to which Building Permit No. 16606Z dated ...N..O.V....8.: i .1.9.8. 7. ........... was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ......... .0.N.E. FA.MILY DWELLING~ ATTACHED GARAGE AND DECKS. ' The certificate is issued to YASILIOS AND MARIA GEORGIADES ' ..................... io¥.b;, of the aforesaid building. Suffolk County Department of Health Approval 87- S 0- I I Nov. 9, 1988 UNDERWRITERS CERTIFICATE NO. N041600 Oct. 26, 1988 PLUMBERS CERTIFICATION DATED: American Plumbing 10/31/88 AMENDED 11/10/88 to increase size of deck. / Building InspectOr ' ' ' Rev. 1/81 FOEM NO. ~ TO~N OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, N. Yo BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) N~6606 Z Permission is hereby granted to: ~ .......~.....~. ........ ..................................................... P.e.,. to .... c~, ....~:r3~L ...... ,.....9~... ............... . ot premises Iocoted at ...~'~..~'...~. ~..~...~. ........... ~ .... ~ ..................... ""-;'":'r'~'"':"~'"'~¥c,~d2,J.~ ....... ~i"~' ............. ~[~ ............................................................. · ~-~*..-......-~,-.., · ~ .~e ",w~c~ ~..,._....~... . .... , .... '~ ..... .~7;=~ ...................................................................... County Tox Map No. '000 Sect,on ..... ..~....q,....O( ....... Block ~ I... Lot No ...~, .~. pursuant to application dated ..... ~,~....~. ................. , 19,~....~.., and approved by the Building Inspector. Building Inspector Rev. 6/30/80 THE NEW YORKBu.,.AuBOARDo~, ,,~.,,cm.,cm.OF FIRE UNDERWRITERS THIS CE~IFIES THAT ~s examin~ on and /~nd to ~ in ~mpllence ~i th the r~ui~me~t~ o/this ~. RXTUIm FIXTUImS OVENS OUTLLrrS SWITCHES FLUOWESCENlf DRYERS FURNACE MOTORS TMM CIOC~ UNIT HIATERS MULTI-OUTLET SYSIIMS NO.O~ ~IT ClRVICl OtSC;QflNICT S I R V I C ii 4f0 BOX 215 h 1C F,,NS)~; N',). Thi~ cml~ke~e m~{ net be altered in uny menm, r~ return te the o~:e of the Board i{ i~,orre~. P~r ,.~ ,~ ~ be their credentials. ~ I~ll~ DEp~ WT. THIS ~ OF C~RTIFICATE MIJ~T ~ BE &L?E~,#4 ~ W4ME~. TOWN OF SOUTItOLD OFFICE OF BUILDING INSPECTOR P.O. BOX 728 TOWN HALL SOUTHOLD, N.Y. 11971 TEL. 765-IS02 CERTIFICATION Building Permit No. Owner /~/'~/- ~d:~fZ~L~,~'~ ~-~ (please print) Plumber ~~ (please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. er s signa~ e) -- Sworn to before me this _~/ day of , 19 ~ · Notary Publi~'~/~ ~rS-''~ County Notary Public MAYOR GEORGE W. HUBBARD TRUSTEES STEPHEN k CLARKE JEANNE M. COOPER DAVID S. CORWIN GAIL F. HORTON SUPT. OF UTILITIES JAM~,S [. MONSELL 236 THIRD STREET P,O. BOX AH GREENPORT, SUFFOLK COUNTY NEW YORK 11944 November 1, 1988 Mr. Norman Wagner Suffolk County Health Department Suffolk County Center Riverhead, N. Y. 11901 Dear Mr. Wagner: The following water service line was connected to the Public Water Supply by the Village of Greenport during April 1988. The installation was done according to our rules and regulations and, to the best of our knowledge, meets with the Suffolk Couoty Health Department standards. UTILITY OFFICE TEL. (516) 477-1748 POWER PLANT TEL. (516) 47%0172 .~asilios Georgiades - North Road, County Road 48, Greenport - Job #1988-6 - Installed 4/22/88 - Ref. #87-S0-11 STE Construction Corp. - Builder. If I can be of further service, please contact me. Very truly yours, H. B. Sherman Ass't Supt. of Public Utilities HBS:lkm 100 Years of Community Service 477-2525 SOUND SHORE EXCItVJATING CORP. 477-187o LocatecJ at SOUND SHORE SERVICE STATION Main Road, P.O. Box 159 East Marion, New York 11939 As of July 1, 1972, a CERTIFICATION £or each completed private subsurface sewage disposal system will be required from the contractor or installer prior to the issuance of final approval by this office. This certification is to be on Company letterhead and shall contain the following information: HEALTH DEPARTMENT REFERENCE NO. 87-SO-I1 PROPERTY LOCATION (include tie distance to nearest cross street) Rte. 48 - Accross_from A_12~er~.,~on Lane HAMLET Greeoport ....... TOWNSHIP SUBDIVISION LOT NU~ER TYPE OF SYSTEM INSTALLED: Septic Tank (a) Volume' 900 Gal. " (b) Type (precast, equivalent, block) _ Pr~cas% Leaching pools: (a) Number and size of pool's (b) Type (precast - block) , Th[ge 4,~ x ~' Precast hereby certify that the private subsurface sewage disposal system described above has been installed according to current criteria of the Suffolk County Department of Health. DATE: Ogt. 28, 1988 S IGNATU RE, ~:;~ .. TITLE ,, ~res. , HENRY P. SMITH, President JOHN M. BREDEMEYER, Vice-Pres. PNILLIP J. GOUBEAUD ALBERT KRUPSKI, JR. ELLEN M. LARSEN BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Town Hall, 53095 Main Road P.O. Box 728 Southold, New York 11971 November 28, 1986 TELEPHONE (516) 765-1892 Mr. Roy L. Haje, President En-Consultants, Inc. 1329 North Sea Road Southampton, New York 11968 Re: Nicholas Tortoro 1000-044-1-29 Dear Mr. Haje: The following action was taken by the Board of Trustees-during their regular meeting held on November 25, 1986 regarding,your request for notification of jurisdiction on the above captioned matter. RESOLVED that the Southold Town Trustees declare "No Jurisdiction" on the project submitted by En-Consultants, Inc. on behalf of Nicholas Tortoro to construct a single family home, sanitary system and driveway as proposed on the map of property surveyed for Mohring Enterprises, Inc. dated March 31, 1983, all construction greater than 100 ft. from M.H.W. and all in accordance with the D.E.C. Permit No. 10-83-0403 issued. Yery truly yours, Board of Town Trustees HPS: ip cc: Bldg, Dept, Board of Appeals C.A.C. D.E.C., Stony Brook file Application Identification ~o,; Check ~ ' Money Order [] Check or M,O, No.: ~ ~' ?/ 32-14-13 (9/77) /o-&¢ March 5, 1987 Mr. Nicholas Tortora 1540 Cottontree Lane St. Louis, MO 63146 Re: Permit # 10-86-1521 Dear Mr. Tortora: In conformance with the requirements of the State Uniform Procedures Act (Article 70, ECL) and its implementing regulations (6NYCRR, Part 621) we are enclosing your oermit. Please read all conditions carefully. If you are unable to comply wi th any ~onditions, please contact us at the above address. Also enclosed is a permit sign which is to be conspicuously posted at the pro- ject site and protected from the weather. Very truly yours, Deputy Regional Permit Admlnist a enclosure ,95-20-6 (9/86)-- 25c 10-86-1521 EAClLITYfPROGR^t'~ NUMBER(s) N/A Article 15, Title 3; 6NYCRR 327, 328, 329: Aquatic Pesticides Article 15, Title 5: Protection of Water Article 15, Title 15: Water Supply Article 15, TiUe 15: Water Transport Article 15, Title 15: Long Island Wells Article 15, Title 27: Wild, Scenic and Recreational Rivers NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION PERMIT Under the Environmental Conservation Law L~ 6NYGRR 608: Water 0uality Certification F----~ Article 17, Titles 7, 8: SPDES L------] Article 19: Air Pollution Control* ~---~ Article 23, Title 27: Mined Land Reclamation [----~ Article 24: Freshwater Wetlands N--New, R--Renewal, M--Modification, C--Construct (*only), O--Operate {*only) EFFECTIVE DATE 3/5/87 EXPIRATION DATE(s) 3/31/92 ~rticle 25: Tidal Wetlands N [-~-~,Article 27, Title 7; 6NYCRR 360: Solid Waste Management* ~-~ Article 27, Title 9; 6NYCRR 373: Hazardous Waste Management [-~ Article 34: Coastal Erosion Management [-~ Article 36: Floodplain Management ~--~ Articles 1, 3, 17, 19, 27, 37; 6NYCRR 380: Radiation Control PERMIT ISSUED TO Nicholas Tortora ADDRESS OF PERMITTER 1540 Cottontree Lane, St. Louis~ MO 63146 AGENT FOR PERMITTEE/CONTACT PERSON J TELEPHONE NUMBER Roy L. HaJe~ En-Consuttants~ Inc. I 516-283-6360 NAME AND ADDR[~SS OF PROJECTJFACILITY (If different from Fermittee) Middle Rd. (C.R. 48) - North Side opposite Albertson Lane LOCATION OF PROJECT/FACILITY J COUNTY TOWN/C~-~[~I~/~,~ UTM COORDINATES North Rd.~ Oreenport Jsuffolk Southold DESCRIPTION OF AUTHORIZED ACTIVITY Construction of a single family home with sanitary system and driveway in accordance with the attached NYSDEC approved plan, GENERAL CONDITIONS By acceptance of this permit, the permitfee agrees that the permit is contingent upon strict compli- ance with the ECL, all applicable regulations and the conditions specified herein or attached hereto. 1, The permittee shall file in the office of the appropriate regional permit administrator, or other office designated in the special condmons, a notice of ~ntention to commence work at least 48 hours in advance of the time of commencement and shall also notify h~m/her promptly in writing of the completion of the work 2 The permitted work shall be subject to inspection by an authorized representative of the Department of Environrnental Conservation which may order the work suspended if the public interest so requires pursuant to ECL §71~)301 and SAPA §401(3) 3. The permittee has accepted expressly, by the execution of the application, the full legal responsibdRy for ail damages, d~rect or indirect, of whatever nature, and by whomever suffered, arising out of the project descmbed herein and h~s agreed to indemnify and save harmless the State from stats, actions, damages and costs of every name and descrip~ 3/5/87 Jclifford C. Wray~ Jr. ldo. 40~ SUNY~ Rm. cc: C.T. Hamilton ~'~ ~ 219~PageSt°nYl of Brook ~4 NY 11794 c~';'?a~ "'- ' ' ' SUPPLEMEIqTARY SPECIAL CONDITIONS. 72.'i, .... L._[ iL:i:._' '~e~it' ~dnditions L are i unclear ~'- ~he. pe~ittee shall, contact '.,?'J.~,~L:.-- the Division of Regulatory Affairs at the, addres~ and titephone noted below. ?a,.?,y ,.,. ......... B. A'copy of this pemit or approval and supplementary conditions shall be available at the project site whenever authorized wolk is in C. The pe~it si%n enclosed with the permit or a copy of letter of approval shall be protected from the weather and posted in a conspicinus location at the work site until completion of authorized work. D. At least 48 hours prior to commencement of the project, the permittee shall complete and return the top portion of the enclosed receipt form certifying that he is fully aware of and understands all provisions and conditions of this per. it. Within one week of completion of the permitted work, the bottom portion of that for~ shall also be completed and returned. E. For projects involving activities to be accomplished over a period er more than one year, the permittee shall notify the Regional Permit Administrator in writing at least 48 hours to the commencement of resumption of work each year. F. If project design modifications take place after permit issuance, the permittee shall submit the appropriate plan changes for approval by the Regional Permit Administrator prior to undertaking any such modifications. The permittee is advised that substantial modification may require sub- mission of a new application for permit. G. ~11 necessary precautions shall be taken to preclude contamination of any wetlands or wate~ay by suspended solids, sediment, fuels, solvents, lubricants, epoxy coatings, paints, concrete, leachate or any other environmentally deleterious materials associated with the project work. H. Any failure to comply precisely with all of the terms ~and conditions of this permit, unless authorized in writing, shall be treated as a violation of'the Environmental Conservation Law. I. The permtttee is advised to obtain any permits or approvals that may be required from the U.S. Department of Army Corps of Engineers, NY District, 26 Federal Plaza, New York, NY 10278, (Attention: Regulatory Functions Branch), prior to commencement of work authorized herein. J. The granting of this permit does not relieve the permittee of the responsibility of obtaining a grant, easement, or other necessary approval from the Division of Land utilization, Office of General Services, Tower Building, Empire State Plaza, Albany, NY 12242, which may be required for any encroachment upon State-owned lands under water. Regional Permit Administrator NYS Dept. of Environmental Conservation Bldg. 40, sUNY--Room 219 Stony Brook, NY 11794 (516)'~751-7900' DEC # 10-86-1521 page 3 of 4 95-2C~6~ ({/06)--25¢ ADDITIONAL GENERAL CONDITIONS FOR ARTICLES 15 (Title 5), 24, 25, 34, 36 and 6 NYCRR Part 608 [ if, in t. he opinlon of the Department o( Environmental Conservation 14 ) other environmentally de~eterlou$ materials associated with the project Any material dredged in the prosecution of the work herein permitted shall be removed evenly, without leaving large refuse piles, ridges across the bed of a waterway or floodplain or deep holes that may have a tendency to cause damage to navigable channels or to the banks of a waterway. There shall be no unreasonable interference with navigation by the work herein authorized, If upon the expiration or revocation of this permit, the project hereby authorized has not been completed, the applicant shall, without expense to the State, and to such extent and in such time and manner as the Department of Environmental Conservation may require, remove all or any portion of the uncompleted structure or fill and restore the s~te to its former condition, No claim shall be made against the State of New York on account of any such removal or alteration If granted under Article 36, this permit does not signify in any way that the project wi[I be free from flooding If granted under 6 NYCRR Part 608, the NYS Department of Environ- mental Conservation hereby certifies that the subject project will not contravene effluent limitations or other limitations or standards under Sections 301, 302, 303, 306 and 307 of the Clean Water Act of 1977 {PL 95-217) provided that all of the conditions listed herein are met , All activities authorized by this permit must be in strict conformance w~th the approved plans submitted by the apphcant or his agent as part Such approved plans were prepared by l~.oderiek Yan Tu¥1, ?C on 1 1/13/~5-- SPECIAL CONDITIONS 20. There shall be no disturbance to naturally-occuring vegetation within 75' of mean high water. 21. There shall be no f~lling or disturbance within 75' of the existing tidal wetland. 22. There shall be no grading, excavating or filling withiR. 75' of mean high water, nor construction of any structures within 75' of mean high water without first applying to this office for said work. 23. Driveway and parking area shall be constructed of permeable materials. 24. Roof runoff shall be directed to a dry well collection system. 25. This project, as described, shall be constructed with strict adherence to local floodplain ordinances administered by the established local administering agency. Supplementary Special Conditions (A) through (J) attached. Additional Supplementary Special Condition (M) attached. 10-86-1521 Page _2 of z~ TKE FOLLOUIIIG c,o~,q3I'f!OI~S C~LL ZPPLY IF CI!ECKED AS APPLICABLE BY TIIE REGIOUAL PERi,IT ~i0~!IU!STP~ATOii: Ail dredging shall be conducted so am to leave a uniform bottom elevation free of mounds or hole~. x Il. All~ spoil material shall be disposed of either in the Atlantic Ocean or at an approved U.S. Government D~mping Ground~ as directed by the District Engineer~ UoS. Depart- ment of the Army, Corps of Engineers. Any spoil material not intended for such water disposal shall be removed from the site and disposed of at an approved upland site. Ail fill and spoil material shall be suitably contained at the work site so as to prevent its eroding, leaching or othe~- wise entering into adjacent wetlands and waterways. Ail peripheral rip-rap berms, cofferdams, rock revetments, gabions, bulkheads, etCo shall be completed prior to placement of any fill matemial behind such structures. Ail repairs to existing structures shall be confined to placement of existing structural elements with no change i'~ design, dimension, or materials, unless specifically authorized herein. DAT~:,,, 3,/5/87 DEC # 10-86-1521 REGIONAL PE~IT ADIflIIISTRATOR Division of Regulatory Affairs IUfS Deft. of Environmental Conservation Bldg. 40, SUNY, Room 219 Stony Brook, l',~f 11794 (516) 751-7900 Page 4 of 4 1987 Chief ~ ~L~K~NE REGIILATO~k' S~':~?%Z)~~, ~IYS DEC, Bureau of ~arine H~bl;~at Frotec~.-ion Bldg. 40~ SU~,I¥, Rm. 225 Stony Brook, I'l. ¥. 11794 Re: Permit I~o. Issued 1'o. Contractor's Address.__ ........ Contractor's Phone Dear Sir: Contractor's ~ame Pursuant to General Condition No. 1 of the above referenced p~rmit you are hereby notified that the authorized activity shall · This Notice is to be sent at least two days in vance of commencement of the project. The Permit sign will be the site and copy of Permit will be available at site for inspectioa~ Submitted by ~AT~; FAILURE TO NOTIFY OR POST SIG[I UILL LEAVE SI%JERrY'S/OR COI~TP~CIOR JECT TO APPLICABLE PE~ALTIES FOR NO~-CO}~LIAb]CE'I'~ITH PE~,IIT COI~DIT!OES. C~iAP~EB T. }LA/iILTOM Chief, Marine Regulatory Section I~S DEC, Bureau of llarine ~abitat ?rotection Bldg. 40, SUNY, Rm. 225 Stony Brook, N. Y, 11794 Re: Permit l~o. Issued To. Contractor's Address. Contractor's Phone New York State Department of Environmental Conservation NOTI, CE The Department of Environmental Conservation (DEC;) has issued permit(s) pursuant to the Environmental Conservation Law for work being conducted on this site. For further informa- tion regarding the nature and extent of work approved and any Departmental conditions on it, contact the Regional Permit Administrator listed below. Please refer to the permit number shown when contacting the DEC. Permit No. ~ Expiration Date NOTE: This notice is not a permit '~.~.~--,-~ Regional Permit Administrator FOt(M NO o 11 TOWN Of." SOUTHOLD BUiLDINO DEPARTMENT TOWN HALL SOUTHOLD, NY DEV EL0 PM ['~T I'ERM IT ~._~. __~_<;.t.~_.~__~_~_~_ ~/e__~.~_~ ~._ ~ Ccuuty Tax M,q~ No. ]000 Ser~tion ~ Block by tho Building I~specto~. BuildinK Inspector 4/50 THE WATER SDPPL¥ & SEWAGE D$SPOSAL OR IHIS RESIDENCE WiLL CONFORM '1'9 /~H£ ~S~AN~A~5 OF ~HE SUFFolK cOUN'~-~b .~, rONS~TS aOequateePpllcent'esan~re~ onelblUly ~0 alt Water a~ dlst FO~ll4 NO. 11 TOWN BUILDiNO DEPARTMENT TOWb~ H^LL SOIfI'HOLD ~ NY DEVELO PMF~NT P~MIT Building InspoctoP Il~!..;,.) TOWN OF SOUTHOLO FORM NO. 6 TOWN OF SOUTHOLD Building Department Town Hall Southold, N.Y. 11971 765 - 1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY Instructions A. This application must be filled in typewriter OR ink, and submitted m~ to the Building Inspec- tor with the following; for new buildings or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic featu res. 2.Final approval of Health Dept. of water supply and sewerage disposal--(S-9 form or equal). 3.Approval of electrical installation from Board of Fire Underwriters. 4. Commercial buildings, Industrial buildings, Multiple Residences and similar buildings and installa- tions, a certificate of Code compliance from the Architect or Engineer responsible for the building. 5.Submit Planning Board approval of completed site plan requirements where applicable. B. For existing buildings (prior t'o April 1957), Non-conforming uses, or buildings and '~pre-existing" land uses: 1. Accurate sur~ey of p~operty showing all property lines, streets, buildings and unusual natural or topographic featu res. 2.Sworn statement of owner or previous owner as to use, occupancy and condition of buildings. 3. Date of any housing code or safety inspection of buildings or premises, or other pertinent informa- tion requ ired to prepare a certificate. Additions $25.00 FOOLS $25.00ALTERATTON $25.00 C. Fees: ~ 1. Certificate of occupancy New Dwelling $25.00, Accessory '$I0.00 Business $50.00 2. Certificate of occupancy on pre-existing dwelling $ 50.00 3. Copy of certificate of occupancy $ 5.00, over 5 years $10.00 4.Vacant Land C.O. $ 20.00 t.~.~ '~/~/./~f/ 5.Updated C.O. $ 50.00 Date /:'~ New Cons truc t i on ...... Old or Pre-existing Building ............ Vacant Land ............. Location of Property :.~..~,~.?. .... /~.~..~..~--',~....~..O~. ..... ~~~ ~'~ Owner or Owners of Property .... ¢~ ¢., ~ ..... . ...................... CountyTax Map No. lO00Seotion ...~.~ ...... Block .... ~.t. ....... Lot. ~ f Subdivision ................................. Filed Map No ........... Lot No .............. Permit No. Z~. ~ ~.~. Date of Permit ,/~).0 ~ ~/./~'?..Applicant Health Dept. Approval ........................ Labor Dept. Approval ........................ Underwriters Approval ........................ Planning Board Approval ...................... Request for Temporary Certificate ..................... Final Certificate ................... Fee Submitted $ ............................. Construction on above described bu ilding and permit meets all applicable,codes anC-regg lations. FOUNDBTION FOUNDATION (2nd) ROUGH FRAME~ .PLUMBIN~z/ INSULATION PER N. STATE ENERGY CODE FINAL ADDITIONA'L COMMENTS 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION ZND [ ] INSULATION FRAMING ~/~NAL DATE 765-1802 BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ]FRAMING [/~L DATE 765-1802 BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION /ND [ ] INSULATION DATE 765-180Z BUILDING DEPT. INSPECTION FOUNDATION 1ST I- ] ROUGH PLBG. FOUNDATION ZND [~NSULATION FRAMING [ ] FINAL ! 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ]~ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING REMARKS: FINAL BUILDING DEPT. NSPECTION? FOUNDATION 1ST .~] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION FRAMING FINAL DATE ,, (,-///~,/~'''.~ INSPECTOR ~ '~, 765-1802 BUILDING DEPT. INSPECTION FOUNDATION 1ST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] ~/OUNDATION 2ND [ ] INSULATION / FRAMING [ ] FINAL DATE ~/~,/i~~. INSPECTOR 765-1802 BUILDING DEPT. INSPECTION /FOUNDATION 1ST [ / FOUNDATION 2ND [ [ ] FRAMING REMARKS: ] ROUGH PLBG. ] INSULATION [ ] FINAL DATE 765-1802 BUILDING DI INSPEC~~//~ ~ FOUNDATION 1ST [ ] FOUNDATION 2ND FRAMING/ ['~ ----- - INSPECTOR ~ ]'65-1802 BUILDING DEPT. INSPECTION FOUNDATION 1ST [~ ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION FRAMING [ ] FINAL Examined '. J0 ~..~.., 19 ~..~. Approved 'FORM NO. 1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL $OUTHOLD, N,~Y. 11971 TEL.: 765-1803 BOARD OF IiEALTH / 3 SETS OF PLANS .e~. .... SURVEY .......... C~ECK .......... SEPTIC ~ORM ~ .......... : NOTIFY CALL ................ , MAIL TO: Disapproved a/c ..................................... (Building Inspector) - , , ' APPLIcATIoN FOR BUILDING PERMIT ' " ..... ; ' INSTRUCTIONg Date .................. , 19. a. Tkis application mbs} be completely filled in by typewriter or in ink and submitted to the Building Inspector, with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli- cation. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to premises and in building for necessary inspections. ,, / admit authorized inspectors on ~, .... ~'m' ..~:.' "~'~ ~% ........... (Si~,nature of applica~it, or flame, if a corporation) .5.0...~.'r...l~h...w....t~. :.,. g. ~.c. ~.V.~..~..~. ~ .vi..,%.... (Mailing address of applicant) [~:.a~O I State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder. t0. .o. ........................................................... Name of owner of premises ...~..~.~..k~.k..e~..~,..~...~,0~('~l,~x..~.-.-~.~.{~.~..5.~:~ .~2~..~..~. ................... (as on the tax roll 6r latest deed) If applicant is a corporation, signature of duly authorized officer. ............. ........................... ,° .q L (Name and title of corporate officer) - .~A.. t/' ', ALL CONTRACTOR'S MUST BE SUFFOLK COUNTY LICENSED Builder's License No .... N~.'r..~.~. I~.~.T.~.IO ..... Plumber's License No ......................... '7(ob Electrician's License No ....................... O{~her Trade's License No ...................... I. Location of land on which proposed work will be done~ ................................................. House Number Street llan]let County Tax Map No. 1000 Section ...... . .C~...~. ..... Block ....... I ........... Lot .... a..~. ........... Subdivision ..................................... Fiied Map'No ............... Lot ........... r-r :. (Name) 2. State existing use and.occupancY of premises and intended use and occupancy of proposed construction: a. Existing t/se and occupancy ... x ..... b, Intended use and occupancy ...... ~_~. 3. Nature of work (check which applicable): New Building ....~[ .... Addition .......... Alteration ...... Repair .............. RemoVal .............. Demolition .............. Other Work .............. (Descripl ion) 4. Estimated Cost ..... ~ .................................................. , ~ (to be paid on filing this application) ~nits . .~ .b~..~.~.. ~ ! ) Number of dwelling units on each floor... 5. If dwelling, number of dwelling If garage, number of cars .... .-~'~ y~/.~::>t~ .... {,..~,~ ................................... '~' 7k ............. 6. If business, commercial or mixedloccupancy, specify nature and extent of each type of use ..... /..~. ............ 7. Dimension Front.. DOD?,-* ..... Rear .............. Depth ............... Height ......................................................... r or additions: Front ................. Rear .................. Depth j. 1ffi4 ~'ll'- ~ ........ Number of Stories... ~ · · ~,. · '-.8. Dimen ,: c ; rew col t~ .. ?.&'... ~ .... ,Rear .. ~ )....~ .... Deptn .... ~ .......... 9. S~ze'oflot: I~llll .... Rear ..l~.~.~ ........... Deptll ..~.~..~..~%.'~..'. ........ · ~ ~ ~'~ ...... Name of Former Owner ~.. [ ........... ~ ........ 11. Zone ou use district in wh p ¢' · ......................... 12. Doesproposedconstruc~[ionviol~t~pnyzonjngl_aw, ordina_n.c_e or regulation: ..INI(~. ................ . .........;. 13. Will lot be re,Faded .~ -. 12..1, .t~..t~...~!.~..~.T. ~.~excess fill be removed from premises:t _..,~esa ~ ~,.,o 14. N;une of Owner of premmes ~. ~['/~S. f--~..~.. [~.[J~.~ress .. ¢.1.~..1~..~. [~.~.~. .... Phone No. ~ ........... Nme of Architect .M~ .~..'~%~'~ .1~..~. '. ?~.'..~.: · · Address . . I~;>C~..~ .F~. !.~. ..... Phone No. '~..~.'. .~'. ~:~.~..~- Contractor ! Address ' Phone No Name of ............................................................. 15. Is this property located ~ithin 300 feet of a tidal wetland? *Yes .~.. No ..... · Ii! yes, Southold Town TruStees Permit maybe re~uired. PLOT DIAGRAM Locate clearly and distinctly all Ibuildings, whether existing or proposed, and. indicate all set-back dimensions from property lines. Give street and block humber or description according to deed, and sho',y street names and indicate whether corner lot. 6 STATE OF NE~ypl~K. cou Y OF :?. · · · · S.S , ..... . .~. ff.~.t'..~....~.'...~...-~'.(?.~..~. ~ .~.~.~.d~.....f'. ............ being duly sworn, deposes and says that he is the applicant (Name of individual sig~ lng contract) above named. ~ He is the ........................... i~;~r~i~rl ~t', 'C;;l};;a't; 'o'f~i~;;,'e't~.') ............................ of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file thL' application; that all statements con~ained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application fi!ed therewith. Sworn to bef6re ary'P li , ~' /' "' ' ':? i -" r ~. ~STANDARDS OF THE SUFFOLK COUN~,~ [~ /-~" "' ~ ~ ~'* - ' ~PARTMENT OF HEALTH SERVICES__ / / / L:D~J~~ '=LASU, FFOL-K.,COU~IY DEPT. OF HEALTH SERVICES THE WATER SUPPLY & SEWAGE DISFOSAL <:/YqT'EI~J~J ,-'~)z.,.. ~J ~ · - . . ~ FOR A~P~0Y~ OF CONSTRUCTION ONLY FOR THIS RESIDENCE WILL CONFORM ~ ~H[ ~: '; :~ /'' ' " ' DATE / ,, HS. REF. NO. / APPROV~ D / ~u~l O~ HEALTH, fOR APPROVAL OF CONSTRUCTION ONLY RODERICK VAN TUYL. P.C. GREENPORT NEW YORK SUFFOLK CO HEALTH DEPT. APPROVAL H S NO STATEMENT OF INTENT THE WATER SUPPLY AND SEWAGE DISPOSAL SYSTEMS FOR THIS RESIDENCE WILL CONFORM TO THE STANDARDS OF THE SUFFOLK CO DEPT. OF HEALTH SERVICES. (si APPLICANT SUFFOLK SERVICES -- FOR CONSTRUCTION ONLY DATE: H. S. REF. NO APPROVED: COUNTY DEPT. OF HEALTH APPROVAL OF SUFFOLK CO. TAX MAP DESIGNATION: DIST. SECT BLOCK PCL. ooo 044 z9 OWNERS ADDRESS: DEED: L.-I Il TEST HOLE CGA~ 3 E ,~ b-~rAM p -'- SEAL k k ~oU'g0 114. ~$' //~ ' ~ ~ /o. eg- I · GENERAL CONSTRUCTION 30. 31. 32. " 1. SITEWORK f,i a. Contractor to clear and grub site within construction limits only. ,:': b. Fill material to be clean fill and compacted in layers es directed by ?~'~ Architect. i:~ c. Edging - All paved areas to have continuous 5/4 x 6" ((:CA Treated) band (6" ,.i vertical) with 2" x 2" stakes (CCA Treated) x 3'-0" Ion!l, 3'-0" o.c. and at · -: all splices (walks, driveway etc.) top of edging fo be fll,sh with paving. ' ;! d. Walkway to front door red brick on 4" sand, e. Contractor to protect natural slope to beach during construction. f. New trees and shrubs to be by Owner. g. Driveway to be 4" deep scree ngs blend mater al with top of 2 courses of ] n /4 stone chip surface w th oi penetration. 2. CONCRETE - 3000 psi at 28 days ASTM 9416g ready-mixed concrete. 3. STEEL BAR REINFORCING - ASTM 615-68 welded wire Fabric - ASTM A-185. 4. VAPOR BARRIER - ASTM E-?6 Polyethylene film 6 mil thick. 5. STRUCTURAL STEEL - (~Llntels, Plate, Girders. sefc~ fo be ASTM A-36 grade. nam-mr - Ho. 1 ~roae with Fb = 1400 psi and E: 1,50ri,000, 19~; M.C. & No. 2 (non-bearing) b. Plywood !:., 11 Subfloor - 32/16, 1/2" th., C-D interior APA with e.:terJor glue, plus :. ]/4" A.C. plywood overlay. ~ ,[ 2) Wall Sheathing - 32//6, 1/2" th. C-D exterior APA. 3) Roof Sheathing - 32/]6, 5/8" th., C-D exterior APA c. Connectors - Taco Co., or equal all fo be galvanized. 7. AIR INFILTRATION BARRIER - "Tyvek" material or approve t equal installed over exterior wall sheathing. 8. WOOD STAIRS - Douglas Fir treads, pine stringers ~ see ~lani - inferior to basement and first floor fo second floor. 9. PLASTIC LAMINATES - Formica - Color as selected by Own r - Satin Finish. Backer sheets fo be used on all work. 10. ROOFING - Joh~s-Mansville "The Wood[ands", 14" x 35-9/14, 5" exposure, Class A or apprr~,-d equal. Color selected by owner. Insta[J over ]5~ building feD. i 1. LEADIzRS AND GUTTERS - Aluminum gutters and leaders, wi~ite finish, gutters.032", downspouts 3" x 4",.027", roof apron.027", end caps,027", sealant material - Alcoa Gutferseal, die cast downspout anchor, strap hangers for fascia and roof apron. 12. SHEET METAL FLASHINGS - Shall be lead coated copper at ,:ill roof penetrations and wail/roof intersections. 16 oz. min. 13. TERMITE SHIELDS - Shall be 16 oz. aluminum. Provide sill sealer (polyethylene) under sill plate. ]4. FASCIA AND WOOD TRIM - Clear cedar - Shiplap al] joints vertically at butt condition typical. 15. SIDINQ - Clear cedar vert ca s d ng "x 6" applied vertical I, over air nfiJtration barf er - fet non-corrosive nailing (zinc coated). ' 16. WALL BASE - 3/8" x 3-1/2" height pine with ]/4" radius at top edge. Mitre all corners (clear). 17. SKYLIGHTS - Insuledome or equal. Supply with tempered glas~ and insect screen, Type L Flashing, Slimshade in White. 18. FIBERGLASS INSULATION - with foil-faced vapor barrier by Owens-Coming. Thickness as follows: a. 9*' - between rafters (vent space above) b. 6" - between studs (6" partitions) c. 6" - between basement and spaces above d. 3-1/2" - between adjacent rooms - horizontal and vertical l?. RIQID INSULATIO,N - Po y socy, onurate "Tberma,x_Board or eau~J 3" /nsulation. ~. .'~_-~-~ -~- ' /-.~-/ .. , , minimum, roof 20. DOORS AI~D W~D~s a. Interior doors, so]id flush panel oak veneer t b. Windows and Sliding Glass'Doors - Anderse~ co., parma-shield- wh,te. All with screens to match. c. Door Frames - To be made up From 5/4" pine with integral .top and interior trim made up from 5/~" x 2-1/2" pine. Mitre all cuts. d. Exter'ior doors, Bench Mark insulated metal doors, pre-hung. Caulk exterior all around dripcap and flashing at head (exterior).- e. Wood FoJd:ng Doors - Louver Clear Pine. f, Window Trim - Interior trim clear cedar._ 21. HA~ RDWARE a. Locksets - Corbin "Qlebel" Signet" - Bronze. b, Hinges - Hager or equal (Bronze) - removable pins. c, Miscellaneous - Stanley (door tracks, cab, pulis, etc.) d. Stops - flush bolts, pulls,bumpers - Ives. 22. GYPSUM BOARD - 1/2" thick, tape and spackle all joints. 23. CERAMIC TILE/FLOOR TILE - To be supplied by Owner and inst }lied by Contractor. 24. KITCHEN CABINETS' a. Plastic laminated trim flush overlay doors/drawers, custom q~,allty, countertop with formica finish, color as selected by Owne~, 25. PAINTING a. Exterior Walls I) Wood Siding Cabots Bleaching Stain two (2) coats. 2) Exterior Trim - two (2) coats solid white stain, Cabots b. Interior Sheetrock Walls - one (1) coat sealer, two (21 coats flat - color as selected. c. Interior wood walls and ceilings - two (2) coats of dear polyu 'ethane. 26. SHOWER agars - C.M. Ketcham & co., solid brass chrome plate ~ or equ-L 27. BATHROOM ACCESSORIES - (supplied by Owner, ~nstalled by Car tractor) a. Two (21 Towel Bars/Bath, one (11 at Powder Room. b. Toilet Paper Dispenser - one (ii each Bath, one ( ) at Powder Room. c. Soap Dish/Qrab Bar (recessed) - One (11 at Master Bath, o~e ( ) at Guest Bath. d. Soap Dish (recessed) - one (]) at Master Bath, one (Ii at Gues' Bath, one (11 at Powder Room. e. Robe Hooks - two (2) each Bath, one (I) at Powder Room. f. Medicine Cabinets by Kef chum, Master Bath and Quest Ba'~, ~liding door, recessed. 28. FIRE EXTINGUISHERS - Multi-use dry chemical type in cabinet (si~ilar to H-10 by J.L. Industries). Supplied by Owner, installed by Contractor. STUCCO CHIMNEY - Provide scratch coot and finish coat (whi'e) tucco with non-shrink additive. KITCHEN APPLIANCES - supplied by owner, nstalled by ContracN r. GLASS DOORS (Fireplace) - by Reichman - Black Iron, Joseph HatI er (Wyandanch). GENERAL NOTES a. All work to be done In accordance with new York State Bu"di~ t and Energy b. Codes and those of any local governing authority. Soil bearing pressure assumed af 4000 p.s.f. c. Ali footings to rest on undisturbed soil. d. Provide al[ steel lintels, bolts, plates, girders and fasteners as required. Shop coat all steel. e. Structural steel shall comply to the specifications for design, fc bric-tion and construction of steel for building of fha Ad.S.C. f. All framing and connections shall be in accordance with the lan st edition of the National Design Specifications for Stress Graded Lumber a~d Fastenings as published by the N.F.P.A. g. Double joist under partitions which run parallel fo floor joists, e around openings. PLUMBING 1. GENERAL ~ Furnish all labor, materials, equipment, plans, tools, and services necessary and required for proper and COmplete installation of ali Plumbing System and related work, to include but not be limited to, water supply and distribution piping, drainage piping, plumbing flxfures, valveS, traps, waste and vent piping, including ali their respective connections, devices, appurtenances with n the building lines of the pram sas. Plumbing fixtures to include, but not be limited to lavatories, bath tubs, showers, sinks, 2. CODES - Ali work shall conform fo the requirements of the New York State UniFor.n Fire Prevention Building Code and the Suffolk County Department of Health. 3. PIPING - Cold and Hot Water, Type k Copper tubing (ANSI H23.11 with solder type fhtings and joints made with 95/5 softmetal solder. Below ground piping to be Type K copper tubing. Risers and mains to be 3/4 inch, all branch lines to Fixtures to be I/~ inch. 4. WATER SERVICE - Underground water service piping to be 1-I/4 inch, 160 lbs. test plastic. 5. DRAINAGE AND VENT PIPING - Above ground drainage and vent piping ta be ABS Plastic Schedule 40 or PVC with corresponding fittings and joint cement. 6. SANITARY PIPING - Below ground sanitary piping shall be cast iron soil pipe (ASTM-A-741 service weight. 7. FLASHING - Flashing materials to be lead 4 lb./sq, ft. 8. HOSE BIBBS - Hose bibbs fo be non-freeze type with inferior shut-off valve. 9. PLUMBING FIXTURES - Supplied by Owner installed by Contractor. Contractor to provide all roughing, valves, Fittings, etc. For complete job. Owner to furnish fixtures and lavatory and shower faucets. 10. VALVES - Valves to be brass/bxonze body - 125 pslg. Il. CLEANOUTS ~ Cleanouts to be fall size of pipe with threaded brass screw plugs. 12. PLATES - Plates For finished spaces to be chrome plat ~d split brass. 13. PIPE INSULATION _ Pipe insulation to be cellular foam of thickness required by Energy Code. f4. WATER HEATER - Water heater fo be 32 gallon (insulated) oil fired by Bach, or equal, complete with pressure relief valve. IS. Arrange for water connection to public water supply and extend into house at service legation. Owner to pay for permit. ELECTRICAL If tubing II u ed w~ter distributing 8Yiterr piping shall be ~.. l. GENERAL - Furnish all labor, materials, equipment, plans, tools, and services necessary and required for proper and complete installation of ail Electrical ~[ ~ ~ Systems and related ~orK to include, but not limited fo, wiring, lighting, ~, serv,ces, feeders, distribution and protectlon equ,pmenf, connections of -~4~1~~ appliances, grounaing, and including all connections and devices within the scope of the work as shown on the applicable drawings and as normally specified ~ in this type of project. ~ ~ ~ 2. CODES - All work shall conform to the requirements of the New York State Uniform 2_~4~.q4~ Fire Prevention Building Code, New York State Conservation Construction Code, ~ requirements of the Suffolk County Department of Health and the National ~ Electric Code NFPA No. 70~1984 (NEC). SERVICE ENTRANCE AND EQUIPMENT - Single phase 120-240 v 3-wire 200-amp service Undergroun~ type. o. The undergro~ad service sbell be complete with service )~eder From the uthDy company's service pole to a meter pocket box on the exterior surface of the building and a main service disconnect switch within the building. The underground service cables may be of the multi-conductor direct burial type or of individual conductors enclosed in rigid steel galvanized or rigid P.V.C. conduit. The termination at the service poles with or without o property line or service end box shah be in accordance with the requirements of the utility company. The direct burial cable shall be installed in conduit where it rises above the ground at the service pole and at the meter socket box. Slack cable of 30 Feet in length shall be left at the service pole for the utility company's use for Final 4. PANELBOARDS: Panelboard boxes shall be standard to the trade of code gauge sheet metal with standard trim and door for surface or recessed panel box mounting. The box and trim shall have: a. Corrosion resisting phosphate treatment and finished with factory backed on gray colored enamel paint. The door shall have concealed hinges, cylinder lock, and a framed directory chart under clear plastic on the inside of the door. The panel sections shaU be mounted away from the back of the box, gutter spaces shall be on both sides, top and bottom in keeping with code requirements. The branch circuit breakers shall be of the plug-on types HEATING VENTILATING AND AIR CONDITIONING GENERAL - Furnish all labor, materials, equipment, plans, tools, and services necessary and required 'o proper and complete insfolJatlon of oJJ HeoNng,Venfi]atlng, and air Cond toning System and r wdJ Include, but not be limited fo, instalJo~i- z . ,elated work. HVAC Systems handling, venting, duct work, and all system ~-'loted piping, valvJng, controls, electrical connections, and all necessary dm cas far complete fully operating system os laid out on fha appropriate dr. ,,.ngs. CODES - All work shall conform to fha requirements of fha New York State Uniform Fire Prevention Building code amd fha Suffolk County Department of Health. HEATING AND COOLING SYSTIEM - Heating and cooling system to be a three (3) zone system, each with its own air hmndling unit, hot water, and DX coils, /ts own air handling unit and controls as shown on the appBcable drawings. ]0. 11. 12. Air handling units each to have /Its own HW (glycol) and refrigerant coil (split system). All equipment items to, be equal or better in q,,aBty and performance than those listed. BOILER - Boiler to be Hell or W~eil McLain~ high efficiency t12 oil fired package, Model P466E with net rating of ~0,000 BTU/Hr. at 180 degrees F. CIRCULATOR _ Circulator, one ~or each zone, to be B & G, Series )00, sized for appropriate gpm wlfh satiable flmw check. Pipe size 1-I/2 inch. Seals to be suitable for glycol solution. FAN COIL UNITS Pan cai/ unJts~ complete wUh housing, blower un t, 110v configured for system shown on dlrowings and with AR[ noise rating Jess than 8.0. Split system condensors tO be desJigned for outdoor insta]laflon, concrete pad mounted, twin fan, double coil, amd energy saving compressor. System to be Trane as Follows: ZONE 1: Air Handler - Trane Model E~WV 736P (1200 CFM) Cooling Ceil - Trane Model c:ompatlble with air handler Condensor Unit - Trane Modell TTX 730 (2-]/2 fan) HW Call - Magic Chef, 2 rmw copper fublng with a]umlnum fins. ZONE 2 and ZONE 3: Air Handler - Trane Model I~WV 730P ~oo~'"g Co~lI i-- Trone Model ,corn~otiblJ]000 QFM) onaensor unit - Trane TTX 7X24 (~-fon) with air handler H.W. Coil - Magic Chef, 2 rmw copper tubing with aluminum Fins. THERMOSTAT5 _ Thermostats fo) be H~ating/CooJing, Day/Night set back equal to White qogers. DUCT WORK - Duct wart to be fobbricate~ in accordance with SMACNA Standards including transitions, bends, take of Ffs, etc., designed for minimum static . losses. Duct material to be galvangzed shoal metal of 26 gauge up fo 24 inches wide and 24 gauge above ~4 inches wide. Se~ms and joints shall be suc~ that leakage is not more than 3~. Duchs shall hav~ rigid fiberglass acoustical and thermal liners, I inch thick for supply and 1/2inch for return· FILTERS - Filters shall b~ Space-Gord, Model 2200, high eFFiciency units. Eight inch deep pleated unih, rated af 99~ efficient with 6 micron size particles. HUMIDIFIERS - Humleitiers ~.o be Auto Flow Model 40, power Jnit with humidistats. DIFFUSERS - Supply diffuser ~vall units to be Hart crd Co-l.yor Air Guide Mode/ V with adjustable opposed blade tampa, rs, adjustable discharge vanes and enamel finished trim. Floor units to b¢ Tuthill and Bailey, 4300 R-LO or Har*& Cooley. Model 411. RETURN GRILLS - Return grillsto be Tuthil] and B~iley Model or Hart & Cooley with adjustable opposed b/ada danpers. 13. ~UEL TANK - Fuel tank to be a 50 gallon steel exterior fiberg ass outside burial in accordance with ufifolk County Hca th Department coated for Standards. 14. CONTROL WIRINQ - All control ~ri[ng to be by HVAC Co~tractor. Line volt,ge wiring by Electrical Contractor. 15. DUCT WORK - Duct work to be broiled to be free from vibraHon, and supported on maximum 8 ft. center. Duct lairs sha~J be properly sealed 1 inch on each side of joints. 16. VOLUME DAMPER - Provide volur~ damper, or other approved air balancing device, with indicating and locking quadradw~hether or not shown on drawings, at each form main duct, at each duct takeoff:, and at each neck to individual diffuser or register Jn supply, return o exhcsff ducts. 17. ACCESS FOORS - Provide access d~rrs as required for coils, filters, dampers, and other equipment that require peF~d. ~service. Doors shall be of the ~me material as the dA~~ ~)~k,~,a~n.d...c..o.r.;b~cted so as to minlmiz leakage. . ]8. HEATING AND I~IHUP41r'IL~ YSTEM _ Heating and air conditioning system be complete with all necessary comt-.~ts and items normally ~,,~ ~r shall Substitutions of equipment shall be nzrc ,~4 ~ .~ - , -. ~p..ed. ~ '-, ~y rne ~rcnitect/Engineer. System operational check-out, including demsst~c -n fo Owner. All appropriate operational and maintenance monual~nall b~ rovided. ]~. COMPLETION - At the completion otthe WOrk -I1 equipment complete with their fittings shall be properly cleaned and, ftn first c~ '~s workin · ' All duct work shall be left clean to p nt . , . g c~ndlhon. _v~e.._ system alsu ~'~tlcn of duct and dirt. System shall be left with clean liars. )0. 11. 12, 14. 15. ]6. with standard A.I.C. ratings for the service voltage. Breakers For convenience outlet circuits shall have sensitive instantaneous trip settings of not more than 10 times the breaker trip rating to prevent repeated arcing of frayed appliance cords. 5. CIRCUIT BREAKERS - Single pole 15 and 20 ampere circuit breakers shall be UL listed as "Switching Breakers" at )20 V a.a. and carry the SWD markings. Circuit breakers shall be UL listed. Single pole breakers with handle ties not acceptable. 6. GR¢.! 'ND RODS - Ground rods shall be 5/8" x 8' copper weld and meet all require~ . nfs of the applicable provisions of the NEC. 7. CABLE AN., ~'!R~NO a. Bronch Circuits (Interior) - Type NM or NMB b. Service Entrance (Direct Burial) - Type USE c. Feeders - Type NM, NMB, or SEC d. Underground Distribution (Direct Burial) - Type UF e. Conr'uc~ors to be copper. f- insulation (600 volt) ttiO AWG and smoJler, - THWN/THHN, //8 AWG and larger - THN, THWN, XHHW (PVC for NM or UF cables). g. Neu!-al wire shall have o white outer covering throughout system. Equipment ground wire shall have a green outer covering throughout system. Mark cables or wire without color coded jackets with non-fading color coded tope af terminal:ohs and other accessible ocofions. ~, RACEWAY - Raceway to be r gid nr metal conduit or Schedule 40 PVC (where permitted by Code). 9.OUTLET BOXES - Outlet boxes dry concealed locations ~n wood frame construction to be PVC wall boxes and noryl ceiling boxes. In exposed locations, use 4" square cast aluminum boxes and finished covers. SWITCHES - Switches, pressure-sensitive type, 15 amp. 120/~77 volt, back and side wired. Single pole, double pole, three-way dimmer, as required. DUPLEX RECEPTACLES _ Provide 15 amp 125 vol, back and side wired duplex receptacles on ali multi-receptacle 15 and 20 ampere circuits. Provide 200 amp ]25 voJf back end side wired duplex receptacle on all single receptacle 20 ampece circuits, Ground fault circuit interrupting _ 20 amp 125 volt with indicator. PLATES - Provide plates for all outlet boxes (receptacle, switch, telephone, blank or combination). Smooth plastic urea (ivory color) unless indicated otherwise. Multi-gang switches, receptacles, etc. shall be in a common, one-piece plate. BATHROOM VENTING - Bathroom venting to be Braun fixture with duct or equal. LIGHTING FIXTURES - Lighting fixtures to be Halo high hats; other fixtures supplied ky Owner. SECURITy AND FIRE PROTECTION a. Security - by Owner b. Fire - provide light/smoke defector on o/1 three levels. ELECTR/CAL EQUIPMENT - Ail necessary wiring, controls, swlfches, motors, and other elecfrJca/ equipment required by other trades (with speclal emphosls on the heating and air conditioning system) shall be provided as necessary for o Complete operationc~ system, as shown on drawings and specified. CENTRAL VACUUM SYSTEM - Air-Vac Model 180 or aqua. Outlets · ' ' ' located as shown an drawmgs. Plpmg to be PVC with manufacturer's approved Fittings. QARAGE DOOR OPENER - Qarage door to have c ' or cable heavy duty opener, 1/2 HP, w~th delayed action hght and remote c~ntrols, hain CABLES - coordinate telephone (3 bedrooms, kitchen, connections (llving room) and operationu.' 'hacks w' basement) and cable TV POWER INTERR ~'r~r~,¢ ^ .... zth the respective cam ani shall be scheduled with the Owner and the local ut' ' ' ~,e JV u,ferrupfions for final ascceptance and oov nf .~: ..... dlty cam any. As re uisite _ ,me..., ,~,*~ur ro Uwner two (2~copies of aq Certificate from U.L. and local authority, showing acceptabilit~ of work done under this Contract. 17. 18. 19. 20. 2). P tlMBElt OAI 1£,4D COAtT£11fr CERr/F/CAi*E OF OCCI. IP,4AiCy OCCUPANCY OR USE IS UNLAWFUJL WITHOUT CERTIFICATE OF OCCUPANCY 4-1 APPROVED AS NOTED N~ ~mLDING DEPA~ENT AT ~18~ 9 AM TO 4 PM ~R THE ~LO~ING INSPECTIONS: FOUNDA~ON ~ REQUIRED FOR POURED CONCRETE ROUGH FRAMING ~ PLUMBING ~. INSU~TION 4. FINAL CONSTRUCTION MUST ~E COMPL~E FOR c.g. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE STATE CONSTRUCTION ~ ENERGY CODES, NOT RESPONSIBLE FOR ~IGN OR CONSTRUCTIO~ ~RRORS~ ' / / , bANE '0 13L40 ' V %01. 0# 40'- ~, Y4" ~ I~'O~ ~ , //~/o" ]® project rifle: drawing title: FCU~DATION FPAN drawn by: [ checked by: I date: Io.q.e7soole: AS drawing number: " ret. no,: .1¸ I o I bOI 0'i 15589 project title: drawing title: l~l~'¢or FbOr_..2E FLAN drawn by: cheoked by: ~:~ date: scale: · IOA .87 ACc drawing number: ref, no,: 1 4'-4" iI iI ~ OPF..hi TO ~4 ~O project title: GEO (&IAOE drawing title: %ECOI4D FLO01~, FL. AkJ drawing r~umber: ref. no.: 1'2 Iq I'Z ~ ~m,/~ro. /F~ff- o~m~i'i~ 12 ~ N P~T~4 ~DV, ll, ]0. 67 ' project~tle: drawing title: ELEVATIOI,4B drawn by: date: lC)_ °1, B7 drawing number: checked by: scale: AS ref. no,: / ~., !hOO ',, \ / x, / t LIVIIg~ l~IN, Ier PL~. ~'T'Of~ t~. $ ~TALI~ '\ project title: drawing title: ~'~07 / r~TAN~ ~1~ ~U,, IO'-0~ ( ~ i,L~L~ A6f.) (,~ ~,,f, A-4) NALI. '1 drawn by: cheoked by: date: scale: drawing number: ref. no.: ,WEATHER PROOF , · , , ~ 2~OV A.C, :SERVICE ~,, ,], A,D. DUPLEX APPLIANCE RECEPTACLE SIDE LIGHT RECEPTACLE RECEPTACLE RECEPTACLE FLOOR RECEPTACLE ~C~S~D CELNG LGHT ~l~ MOUNTED ~NCANDESCENT C~IL[NG MOUNTED UTILITY (I~ICANDESCENT] CEILING MOUNTED UTILITY (FLORESCENT) CEILING LIGHT {SURFACE MOUNTED) L ,~EILING'i ' D MOUNTED LIGRT-HEATER-VENTj/(~)% $'~/fTCH (LOW iVOLTAGE ) ~PEAKER OUTLET UUM OUTLET I I L. I ~oMct ~e: ' ~OI~IADL~F .... Ti drawing rifle: drawn by: checked by: dote: scale: drawing number: o OF Z ref, no,: J I I L I drawing title: ~, ,J L~ drawing number: ref. ilo,: