HomeMy WebLinkAbout16383-zFORM
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No Z-18721
Date JANUARY 17, 1990
THIS CERTIFIES that the building ALTERATION
Location of Property 560 NORTH OAKWOOD ROAD LAUREL, N.Y.
House No. Street Hamlet
County Tax Map No. 1000 Section 127 Block 08 Lot 07
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated AUGUST 24, 1987 pursuant to which
Building Permit No. 16383-Z dated AUGUST 26, 1987
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is
issued is ENCLOSE A PORTION OF EXISTING DECK OF SEASONAL DWELLING
AS APPLIED FOR.
The certificate is issued to
JOHN R. & JILL BRICE
(owRer)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
UNDERWRITERS CERTIFICATE NO.
PLUMBERS CERTIFICATION DATED
Rev. 1/81
N-086612 - AUGUST 14, 1989
JANUARY 10, 1990-JOHN R. BRICE
/BLidi/ngIsectr
l~Ot~ NO, ~
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, N. Y.
BUILDING PERMIT
CTHIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
N_o 16~8~ Z
Permission is hereby granted to:
.......................
. /0. . Iooo~{/
et premises located at ....~ ....... ~,~.......~.~...~...,.....~....~ .......
County Tax Map No. 1000 SectlER'~....~........~. ....... Block ...................... Lot No ......................
~ursuo,t to oppl~co,,on doted ~.~...:~.?. ............. I9.~..7..., ond opprov~ by
the
Building Inspector.
Fee $....~.~....::~
Rev. 6/30/80
TOWN OF BOUTHOLB
BUILDING DEPART}lENT
TOWN HALL
SOUTHOLD, NEW YORK
765 - 1802
APPLICATION FOR CERTIFICATE
OF OC
/
NEW CONSTRUCTION ....... OLD OR PRE-EXISTING BUILDING''~'---VACANT LAND ........
Location of Property.. ~0
.....................................
H . STREET .... HAMLET
Owner or Owners of Property.
County Tax Map No. ]000 Section /~7 Block ~ Lot' ..~ ....
' Snbdivision .... ~).~ ...............
.......... Date of Permit
Filed Map
........ Lot ..........
Permit
Health Dept. Approval ..................
Planning Board Approval
Under~rlterm A p p r o~a 1 . .~.~0
Request for Temporary Certificate .......
Fee Submitted: $
Final Certificate ..........
rev. 10/14/88
TO~/ OF SOUTBOLH
BUILDING DEPARTffl~NT
TO~N HAL~
76~- 1802
~PLICATION FOR ~E~TIFICA~. OF OCC~ INSTRUCTIONS
'~is appllcaclon muse b~ filed in type~iter 0R ink and submitted ~o the Building
Inspector wi~h ~he ~oll~wlng; for new buildings ~or new use:
I. Final SU~ey of pr0p~rty with accurate loca:ion of all buildings, proper~y li~es,
streets, and uuusual~natural or topographic features.
2. Final approval of Health Dept. of water supply and se~erage-dlsposal(S-9
3. Approval of electrlcil installation ~rom Board of Fire Unde~iCers.
4. Sworn statemfin~ from ¥1~ber certifying thac solder used En system contains less
than 2/10 of I% lead.l
~- Co~erclal buildlngs,[ indus~rlal buildings, ~lClple residences and similar.'
buildings and inscal~atlons, a Certlfica~e of code compliance from ~he Archltec~
or Engineer responsible for the building.
~6. S~bmlt Planning Board Approval of co,pieced site plan requirements.
Pot existing buildings (.Prior to April 9, 1957] non-confoming uses, or buildings
and "p~e-existiug" laud ~ses:
I. Accurate su~ey of pr?percy showing all property lines, streets, buildings and
unusual natural or topographic features.
2. A ~roperly completed appllcaClon, a consent ~O inspect signed by the applicant
and a certified abstract of title issued by a title company which shall
show single and separate O~ershlp of the entire Io~ p~ior ~o April 9, 1957.
. Ii a CertifiCate of O~cupancy is denled~ the ~u/Iding Inspector shall state the
reasons ~here~or in ~i~ing~to ~he~ ppl~can~.
3. DaCe of any housing code or safety inspection of buildlngs or premlses~ or other
perClnent in~o~ionirequlred ~o prepare a certificate.
For Vacant Land rtz~zc~Ce of Occupancy:
I. ~ appllcaclon ~or vacant land Certificate of Occupancy shall be submitted,
and a certified abstract of ~itle issuedby a t/tie company showing single and
separate o~ership of[the enClre lo~ prior to April 9, 1957 shall also accompany
the appllcac/on. If i Certificate of Occupancy is denied, the Build/nE Inspector
shall s~ate ~he reasons ~herefor in ~i~ing ~o the appllcan~.
FEES:
]. CERTIFICATE Of' OC~Cy .- Ne~ ~elllnE $25.00, Additions ~o ~elllnE ~25.00,
Al~eratlon ~o ~e!linE ~25.00, Swiping Pool, ~25.00. Accessory building ~25.00
Addition ~o AccesSory buildlnCs, $2~.00 - Buslnesses.~50.00.
2. Cerniflaa~ of OcCupancy on pre-exls~inE dwelllnE - ~]00.00.
3. Copy o~ CerCiflCa~e of Occupancy - ~.00 - over ~ years -
4. Vacan~ Laud CerClflcaCe of Occupancy - ~20.00
5. Updated Cerclflca~e of Occupancy - ~50.00
6, Temporary Cerci~i~a~e of Occupancy - $25.00 Reslden~ial
~50.00 Co~erclal
10/14/88
TO~N OF SOUTtlOLD
OFFICE OF BUILDING INSPECTOR
P.O. BOX 1179
TOWN IIALL
SOUTIIOLD, N.Y. 11971
TEL. 765-1802
To Whom This May Concern,
Plo are unable to complete your Certificate
of Occupancy because.of the following reasons.
/_~/ An application for Ccrtificate of Occupancy
is not on file. ~'~
/~/ No Underwriters Certificate on file.
/.~_/ The check i:;(outdated/not on file_.)~Rj-
/~/ No }lealth Dept. Approval on file.
/-_~/ No final inspection has been made.
P]eat;e contact our office on
Thank you for your cooperation.
Bl,[lding Permit t! / ~ J ~ 3 Z
Dui ld in!l Dept.
this matter.
***/~_/ No Plumbc2r Solder Certificate on file.
( all permits involving plumbinrj being
issued after April 1,1984 )
TOWN OF SOUTtlOLD
OFFICE OF BUILDING INSPECTOP,
P.O. BOX 728
TOWN HALL
$OUTHOLD, N.Y. 11971
C E R T I F,I-,C A T I O N
TEL. 765-1802
Building Permit
(please print)
Plumber ~o~D ~ ~'~
(please print)
I certify that the solder used in the water supply system
contains less than 2/10 of 1% lead.
(plumber's signature'i'
Sworn
NOtary
o before me this
,.
%~ ~ .
Notary Public
TOg'N OF $OUTtlOLD
OFFICIo: OF BUILDING INSPECTOR
P,O. BOX 1179
TOWN HALL
SOUTIIOLD, N.Y. 11971
TEL. 765-1802
To Whom This May Concern,
Ple are unable r.o complete your Certificate
of Occupancy because .of the following reasons.
/~/ An application for { '
_ Cert.flcate of Occupancy
is not on file. ~
/3/ No Underwr-lters Certificate on file.
/.~_/ '['he check /-:; (outdated/not on file.. )~R~r-/
/'~/ No 1{ealt'h Dept. Approval on file.
/-_'/ No final inspection has been made.
Please centact our office on this matter.
Thank you for your cooperation.
Building Dept.
***/~/ rio Plumber Solder Certificate on file.
( all perm}ts involving plumbing being
issued after April 1,1984 )
FIELD ~NSF"R~CTION
FOUNDATION
(1st)
COMMENTS
FOUNDATION (2nd)
ROUGH
FRRME
PLUMBING
INSULATION PER N. Y.
STATE ENERGY
FINAL
ADDITIONAl OMMENTS:
MAR 3 11988
DLDG, DEFer. ,
TOWN OF
March 24, 1988
Mr. Gary Fish
Southhold Building Dept.
Main Road
P. O. Box 1179
Southhold, New York 11971
Dear Gary:
Per our conversation, I would like to amend my building permit #16383 Z
for the additional construction of a foyer on the south side of my
Laurel cottage. This new construction will take place between the
existing structure and the outdoor shower on the deck.
Foundation will be 12"X12" block, 3"-6" beloW grade.
Fireplace chimney will be removed along with woodburning stove.
Enclosed you will find a detailed drawing of the above.
I will be in touch.
Sincere ly,
John R. Brice
JOSEPH GABRIEL, RAPC
73 Rock Road
Islip Terrace, NY 11752
August 29, 1988
Town of Southold
Department of Buildings
Main Street, PO Box 1179
Southold, NY 11971
Attn: Mr. Gary Fish
Dear Mr. Fish:
Regarding the alteration at SIGSBEE Lane for Mr. Norell, the
contractor informs me that you requested clarification on the
constructoin of the exterior walls.
The contractor will construct the walls of:
1/2" sheetrock inside finish
2 x 4 wood studs
R-Il bart insulation
1/2 "plywood
R 7.5 rigid insulation boards
wood exterior shingles
This construction will satisfy the NY State Energy Code and will
suffice structurally.
I trust this letter will satisfy your request.
Sincerely
Joseph Gabriel
President
JG/ao
cc: Budget Construction
0743x
OFFICERS
Donald W. Brice
Robert N. Herman
Alfred J. Forhno
DIE. OF ENGINEERING
& DESIGN
James R. Segraves
SUPERINTENDENT
Robert N. Herman
CONSULTANTS
Wm. C Bnce, PHD PE
Geological Engineer
Alfred J. Fortino
Attorney et Law
Charles M. Fortmo
Attorney at Law
Donald W. Brice
Ciwl Engmeer
April 1, 1988
D.W. BRICE CONSTRUCTION CO., INC.
GENERAL CONTRACTORS
135 N. Court · Alma, Michigan 4880!
517-463-4901
Commercial, Industrial, Resident*a~ Building & Remodeling, Property
Development, Property Management & Construction Management
Complete Engineering Services
Mr. John R. Brice
444 East 86th St. Apt 3-E
New York City, NY 10028
Dear John:
We have calculated the Thermal Resistance (R) for the additlon to your
cabin on Long Island.
The Side Walls have an R Factor of 20.50. The roof has an R Factor
of 21.13.
The basis for this determination is the Michigan Energy Code applied
to one and two family dweliings published by the Energy Administration
Michigan Department of Commerce and the Manufacturers specifications.
SIDE WALLS R
Outside surface .17
3/4" Thermax 6.40
5/8" Plywood 1.00
T-11 ½" Siding .80
3½" Fiberglass 11.00
½" Gypsum .45
Inside surface .68
TOTAL R 20.50
ROOF R
Outside surface --
5/8" Plywood 1.00
½" Gypsum .45
6" Fiberglass 19.00
Inside Surface .68
TOTAL R 21.13
Yours truly,
Donald W. Brice
President - Civil Engineer
Masonry, Wood & Steel Bl~ildinRs ~, Pcmr~vt W,~ll~ & Flat C.m~crete
212/210-0725
Craln Ooramumca[lol~s Inc 220 East 42nd Street, N.Y. 10017-5806
AdvortisingAge FAX #: (212) 867-9716
.... TOWN OF ,~ot.rrl"~. LD _.
Memo from
'ertisingAge
~larketing 220 E. 42nd St., New York, NY 10017
John R. Brice
Sales Representative
Advertising Age
The International Newspaper of Marketing
Memo from
220 E. 42nd St., New York, NY IO017
John R. Briee
Sales Representative
212/210-0160
Advertising Age
7he International Newspaper of Marketing 220 E. 42nd St,, New York, NY 10017
Memo from
John R. Brite
Sales Representative
212/210-0160
creativit
John R. Brice Advertising Manager Magazine of the Creative Process
212/210-0725
BLOG. {3EPT.
Cra!nCommunrcal,or~slnc 220 East 42nd Street, N.Y. 10017-5806
~vortising_t~ FAX #: (212) 867-9716
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
FRAMING [~*~L
INSPECTOR
- /~' -// ~ / 76S-:l.802 ~ ,~
~ INSPECTION
] FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ~ INSULATION
FI~AMING ~ ] F)NAL
765-1802
BUILDING DEPT.
INSPECTION
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [~U~TION
[ ] FRAMING [ ] FINAL
REMARKS: ~.~-z~,~, C,~-..~,.
765-1802
BUILDING DEPT.
INSPECTION
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
[ ~FRAMING [ ] FINAL
REMARKS:
765-1802
BUILDING DEPT.
INSPECTION
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND[ ] INSULATION
[~/FRAMING [ ] FINAL
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION ZND [ ] INSULATION
[~FRAMING [ ] FINAL
DATE ,, INSPECTOR
765-~802
BUILDING DEPT.
INSPECTION
FOUNDATION ~.ST [ ] ROUGH PLBG.
FOUNDATION ZND [ ] INSULATION
]~FRAMING [ ] FINAL
REMARKS:
DATE
765-1802
BUILDING DEPT,
INSPECTION
FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
[~RAMING [ ] FINAL'
- BUILDING DEPT.
INSPECTION
UNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
[/~MING [ ] FINAL
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
FOUNDATION ZND [ ] INSULATION
THE NEW YORK BOARD OF FIRE UNDERWRITERS
35:[0'/
A~C~J!~'i' }-~, ) 9~5 JOHN STREET, NEW YORK, N~[~RK
THI~ ~RTI~IE~ THAT
the electrical ~ulpment ~ ~scrlbed below and int~duced by t~ applicant ~med on the a~e application n~mber in the premizes of
examined on
FIXTURE SWITCHES
OUT'TS
~ 2nd FI. Section Biota
and~ound to be in compliance teith the requ re.~ents ~f thL~ Board.
Lot
FIXTURES
RANGES COOKING DECKS OVENS EXHAUST FANS
DRYERS
MUtTt.OUT~ET
SYSTEMS
E R V I C E
NO, OF CC COND
PER *~
P.O.80X lOS
G~NERAL MANAGER
Per ~ ~ ....
Th'~ the Board if incorrect. Inspectors maybe ~ by their credentlaJs,~
COPY ;FOR BUILDING DEPARTMENT. THIS COPY OF C~RTI~ICAT~ MUST NOT BE ALTERED IN ANY MANNER
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
APPROYEC
· -Zg'--¥" J-
'T
TOP VIEW
~'Z~V, aT/O,V{ I
P. O. BOX 909
MAIN ROAD
t~repared in accordance with the minimum
~tandards for tide surveys ar established by
the L.I.A.L$. and approved and adapted
for such u~e by '[be blew York State Land
1-~tle Ama:tartan ·
o".'" -~° ~'~" sURVEY OF
'°"" LOT 41
AT LAUREL
0 . TOWN' OF SOUTHOLD
~~;z SUFFOLK COUNTY, N-Y-
~ I000 127 - 08
CERTIFIED TO :
~~ N.Y.S. LIC. NO. 49668 TICOR TITLE GUARANTEE COMPANY SCALE !n~ 40'
--' TITLE NO. TI285 - 6075 DEC.' 25, 1985
~CO~C /SURVEYORS ~ ENGINEERS, R C. dOHN R. BRICE
J_
-I-
/2¥' O,C.
FLQOf~ PLAN
ADD! T/OAI
//
['/£VA T'IO~$
FO~M NO. 1 SURVEY
TOWN OF SOLJTHOLD CIiE CK ::: ~V/[
BUILDING DEPARTMENT SEPTIC FORM .............
TOWN HALL
NOTIFY
$OUTHOLD, N.Y. 11971
TEL.: 765-1802 CALL ................
MAIL TO:
Disapproved a/c ................................
(Buudln~ Inspector)
APPLICATION FOR BUILDING PERMIIT
ki\.l ..... _tL7
8LDG, DEPT.
Date . ~ //~' ........ 19557
INSTRUCTIONS
a. Tiffs application must be completely filled in by typewriter or in ink and submitted to the Building inspector, with 3
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets
or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this appli-
cation.
c. The work covered by this application ]nay not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issued a Building Permit to the applicant. Such permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose whatever until a Certificate of Occupancy
shall have been granted by the Building Inspector.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southotd, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described.
The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to
admit authorized inspectors on premises and in building for necessa~ctio.ns.
"(Signature of applicant, or name, if a corporation)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or guilder.
Name of owner of premises . .~:/..t~...~..~..~...~.."~-~ ............................................
(as on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer.
(Name and title of corporate officer)
ALL CONTRACTOR'S MUST BE SUFFOLK COUNTY LICENSED
Builder's License No ..........................
Plumber's License No .........................
Electrician's License No ....................... /~,~ ..~e_ 7~-~ ~ ~ ~-/~-,~Z ,
Other Trade's License No ......................
1. Location of land on which proposed work will be done~ ~~/f?.. ~..-.~.. ~..~...~./:... ~..t:C~> .....
?g..o. q.z? .... .......... ........
House Number Street Hamlet
County Tax Map No. I000 Section .~ .... Block ...... .~. .......... Lot..t~.....~. ........
Subdivision... ~..(X..L)?.-~.} ....~90...~.~ .............. Filed Map No ............... Lot...
(Name)
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use ~ ~
b. Intended use and occupancy
3. Nature of work (check which a cable): New Building .......... Addition ... Alteration : ... >, .- ....
Repair .............. Removal .............. Demolition .............. Other Work ............
4. Estimated Cost ~ Fee ..............
~ ' (to be paid on filing this application)
5. If dwelling, number of dwelhng units ............... Number of dwelling units on each floor ...............
number of cars
If garage, ....~ .....................................................................
6. If business, commercial or mix~d occupancy, spec~y nature and extent of each type ~f use .....................
D~ensions'of same structure with alterations or additions: Front . X~, ~ Rear ' ~,~
Height . .Z.~ .......... Number of Stohes .... ~.~ ....... .t ....
12. Does proposed constructiqn violate any zoning law, ordin~egulation: ~ ...........................
13. Will lot be regraded . .~..i ................ 2' ' ' Will excess fill be remove~fr~m premises: Yes
Nme of Architect ......... i .................. Address .~W~.. ~.Z~ .... Phone No ....... ' .........
Nme of Contractor .0~..~ .~..~ .... Address fM :~.. ~&~.~.. Phone No ................
15. Is this property located~ within 300 feet of a tidal wetland?;~ *Yes .~, No .....
*If yes, Southold To~ rustees Permit maybe required.
Locate cle~ly ~d distinctly dl buHdEgs, whether existing or proposed, and~indicate E1 set-back d~ensions from
property Hnes. Give street and blocg number or description accord~g to deed ~d sho~ street names and indicate whether
(Name of individuai signing contract)
above named.
(Contractor, agent, corporate officer, etc.)
of smd owner or owners, ~d ~s d~ly authorized to perform or have perfomed the said work and to m~e ~d file this
apphcat~on; that all statements contained m thru application are true to the best of his knowledge and belief; and that the
work w~l be perfo~ed in the m~ntr set forth in the application filed therewith.
Sworn to before me this
$~}a~ Public,. ~~~ County
I~VINO
' NO. 00-548a4~0 (Signature of applicant)
Oua[~tied In Nasaau
Prepared in accardance with ,he minimum - , ~-¢-J .,-{~.~S~'~ ~'~o ] ~ ~
aandards fo, ,,tie su,eys as estabhshed by ~ fr'd ~ ~ kk% ~ } ~
the LI.A. LS. and approved and adopted ~ &~ she ~/ ',~. 6 ~ ~
for such u~ by ~be ~eW York StYe Land ~0 ~. ~ ~1 ~ ~ ~ -- ~
, :~ LAUREL ~
~ . TOWN OF'SOUTHOLD ~,
SUFFOLK COUNTY , N.Y.
CERTIFIED TO : ~
~o~~ .'N.~.s. L~..0. 4eeee r~co. r~rL~ euA.A.r~ couPA.~ SCALE !"= 40'
CO~:-~'U~VEYORS a E~el NEERS, R C. TITLE NO. T 12e5 - eozs DEC.* 23, 1985 ':~.
P. O. BOX 909 ~ ~
MAIN ROAD '" ~ ' ~ "
i>repared in accordance ~h the mlnimum ~ .~r-j ~ ,'~' ~ '-
i ~andards for title surveys as established by -~ "d .,~e" ~ ~ .~
/ the LI.A. LS. and approved and adopted -'~ ~,7,. '~ ~ ~' ~o ~"
I for such use by ,be New york State Land ~..~) ~ t ~.~
I ~ -~.~' uo~ L~I --~
SURVEY OF
~ ~ ~ .: ~ ~ MAP O~ LAUREL PARK
~UFFOLK OOUNTY ,N.Y.
:: ~:CO~~4~E'~S 8 E~GINEERS, R C. TITLE NO..TIaa5 6075 ' . DI,C;'2D, 1985
~;' P.o. eox ~o~ ...~
~?::~:..SOUTHOLD, N.~ 11971 .~ , " ,
:' '85-
.....: .'. :. - . .:.. .. --:.. ::: - .._.: . .. . . '-. . · ....... : .............
,i
,",o ,o ¢,-?¢
h/OF<TH O,qI<WOODRD , ti
517E PL,~N
Isgr~,y ~y~
OAL.,~re 7-f-~ ~
f
PLAN
TRF~qTEO
--
"PA"/' coooo ¢c~
yo?oA,~
/S" x ,'ga ~£OCE PIE/:¢~,
6"
F5.7514T'//V~ 1~5 FTE/~,5 d3~
i I
SOUTH
ELEVArTtOff
~AST
ELEVATION
-!
j I
.¢%?,R7- H
T
WE_ST EL£ VhTION
Contractor shall
structural work;
fit and location
Engineer any and
affect or prevent the proper execution and completion of tbs n~w . ~ 26.
work. Notify Architect of all changes.
All construction shall comply fully with the applicable provisioEs of
Do not s6ale the drawings.
other trade. All slots, sleeves and/or other openings to be coordl-
30.
etc. (temporary and/or per, anent) as required for the safe instal]a-
city of ~ tons per square foot, undisturbed virgin soil.
compressive strength of ~5o~ psi at 28 days and r~inforced with
W.W.M. #6 x 6 - 1~ x 10 in garages.
Shop and
ASTM 233
.ively.
verify all conditions covering or affectinq ~he
obtain all dimensi6ns to ins~-th~-pro~er-~tr~ng~h, - 25.~ 'Blind flaMh all junctions where vertical meets
of the structural work; report to the Architect and neys,~-~indow~, do~rs,~etc.). ' ~ ~
all conditions which may interfere ~ith or otherwise ~ '~ - ~
Details and general provisions for concrete construction shall con-
form to requirements of the latest AC1--Building Code, ACI 318, and.
Manual ACI 315.
All structural steel shall be new and'conform to ASTM A36.
The desl~n, fabrication and erection of all structural steel shall
be in accordance with the latest edition of the AISC Specification.
field connections shall be welded or machine bolted with
series electrodes and A307 bolts with lock washers, respect2-
Paint ali
new steel one shop coat rust inhibitive paint and fi'eld
touchrup except for areas to be welded.
All structural welding shall be performed by certified welders in
compl~Dnce with the American Welding Society's Standard, Qualification
Procedure.
Termite protection shall be by means of chemical treatment or metal
termite shield.
All wall bearing beams to have standard angles, anchors, and bearing
pla~es unless otherwise noted.
Ail wood posts resting on top of concrete walls shall have metal sea~s
anchored to concrete base. All posts resting on top of steel beam
shall have clip angles bolted or welded to the flanges of the steel
beam. Bearing plates and moisture barrier shall be provided.
.All structural framing lumber shall be #2 or better. Hem-Fir fb=ll5[
p.s. E=1,400,000 p.s.i. (minimum) with SPF utility shoes and plates.
Wall studs shall be He,Fir ~2 or better. Lintels and headers shall
be as indicated on plans.
All roof and wall plywood panels shall be exterior CDX grade with ex-
terior shall meet the requirements of the latest edition of the U.S.
'Product $~am'dard PS-l, and shall be identified with the appropriate
grade trademark of the ~erican Plywood Association. Ail plywood
subflo6~ panels shall be same as above and shall meet the requirements
of the latest mditions of the U.S. Products Standard PS-l, and shall
be identified with the appropriate grade trademark the American Ply-
wood Association.
All exterior exposed posts, girders, and joists shall be wood ~pressure
treated in accordance with the requirements of the current AWPA Stan-
dards C2 for water-borne preservative treatment. Ail wood must be
labeled certifying copforzaance to requirements direct.
Wood structural members in contact with masonry or concrete must be
preservatmve treated with oil-borne chemicals or creosote to definite
retentions and penetrations in accordance with the AWPA Standards C23.
Searing plates and moisture barrier shall be provided between wood
nembers and wall.
Where rafters and joists frame into other wood beams, provide Teco
7-qrips 18 gage galvanized steel joist and beam hangers.
horizontal (ro~f, chim- -
Ail brick~ to co~ply to S~and~d~ Spea~ficatiDns~fo~ ~uilding ~Brick
AsTM C216-~9 and~h~l be Structure/' C~ay Brick Grade SW. Morta~.fo~
b~ick to be 'Type-,~l~ Masonry u~its 'shall be ~learly i~entlfi~d to ~
spacing of reinforcing must not exceed 32" o.c.
28. Where loose lintels are required in, masonry veneer, use 4 x 3-1/2 x
'~5/16'~hick steel angle (note that first dimension is vertical leg).
29. Skylights (where applicable} shall be double insulated, self-flashing
'with curb. Align with roof rafters and insulate ceiling splay.
All.doors, openings, and window to be set with top at 6'-8" A.F.F. 36.
All material to be installed as per manufacturers recommendations and
specifications.
Provide minimum 25 C.F.M. fan to switch at all bathrooms with no
natural ventilation. Duct exhaust from fan directly to exterior.
All glazing at glass doors, 'entrance sidelights, tub and shower
enclosures shall be fully tempered safety glazing Glass shall be
identified.
FOUNDATION AND
SLAB
a. Foundations .shall be. 8", 10", 12" & 16" poured,concrete with
4" concrete floor slab on&4 mil poly continuous sheet on 4" por-
ous fill.
b. All~oncrete shall be in accordance with ACI Building Code 7.
Foundations to bear a minimum of 1'-0" into undisturbed soil .
-~ith a minimum allowable bearing capacity of 4OD~ ~SF minimum all
1~ ~ccordance~ with ~,~, ~ 5~D~ C~. Exterior fo 'n~
c. Slabs on grade shall be 4" concrete.
d. Remove topsozl and o~r materials before pouring slab. Slabs
on grade shall be pou'red on 4" of compacted porous fill o~ suit-
able on-site material placed over undisturbed soil,over well
c0~pacted fill, for exterior slabs.
e. FoBndation walls shall be dmmp proofed fro~ bottom of footing to
within 1" of grade with a trowel coat bitum[inous mastic. A
water proof me,rahs between coats of mastic shall be installed
if required by site condftions.
f. Concrete finishes will be as follows: Floors - smooth steel
trowel finishes, wood float finish at crawl spaces; walls of
exp0s~ed concrete, shall have snap' tie-holes filled.
35. WOOD FRAMING AZqD MASONRY VENEER
a. Interior walls and partitions will~ be~2" x 4" wood studs 16" on
center with Gypsum board, tgp~d and spackled 3 coats.
~ b. Ex!~rior walls will be 2" x ~" wood studs 16" o.c. with
~M5 N~I~ Sheetrock fastened to the inside of studs. (Outside to be covered
~ wi~h %~11 CD ~ plywood sheathing covered with 15# asphalt
saturated felt covered with finish materials as noted on plans
and elevations.
c. Ali partitions, exterior walls a~d ceilings ~ill be covered with
56~ thick Gypsum wall board, B~ ~p~ firecode
walls and ceiling in qarage aid over boiler ~r furnace.
d. Double all framing under parallei partitions. Provide Fire-
stopping as per and aroundcall openings as re~quired by Co~e.
e. Provide at least double joists and headers at~ water closet
drains, and bathtubs, and all vent and mechanical openings 2'
or more in w%dth, unless otherwise shown in d~rawings. ~
f. Tall joists over 4 feet long and header joist~s shall be hung
in approved metal stirrups or hangers and sp~}ked securely un-
les~ supported on ~ wall or girder.
g. Fasten securely all parts of carpentry work im their proper
place. 8race, plumb and level all members an~ secure with suf-
ficient nails, spikes and bolts to insure rigidity.~
h. Nail lapped joists over any bearing, together with two 10d nail~.
i. Provide solid sur{aces at least 1-1/4 inches w~ide in both dir-
ections all corners for securing sub-f~oorinq, drywall, etc.
F~rm surfaces with framing men~bers or with 2 i~nch wood blocking
secured with at least two 8d nails at each e~d..
j. Provide 1" x 3" bridging between all floo~ joi:sts. Maxim~m~
space between rows of bridging and between bri(dging and supports
shall be 8 feet. ~
39.
Roof goB$t~uc~iQn~haL1 be_uoq? ~afters covered with
plywood sheathing and the roof system consisting of 15 pound
base sheet covered with 240# ~sphalt self sealing shingles.
g~J~io~nns~o~'r-C?t'~eC~ -' r~ ~ ~edesign
~11 lumber ~nd connection.s shal~ ~e-~-ac d eN ' n "
e andw ~
ber is to be furnishe~ and installed, complete with all fasten-
~ mbeL and its fastenings.~ Lum-
zngs, anchors, blocking, bridging, saddles, hangers, etc. required
to complete the job. Al% steel bolts connecting wood members
,shal~ be supplied with and tignte~e~ agamnst steel whshers or
plates. Joi'st hangers and conn.ectors, steel bridging and other
special connections and hardware ~ust be installed in accordance
with ~ ~ ~_~. Building Code requirements.
Exterior brick and stone veneer wails to have non-corrosive fr~e
brick ties 16" o.c. horizontal 32" o.c. vertical nail to studs
INSULATION
a. Insulation in all exterior wall~ shall be ~' fiberglass
equal to trade term R W type
~l,,~- -~ Insulation in roof ceilings shall be
--~ rmoerglass type equal to trade ter~ R-~O. Insulation to
crawl space'and cellar ceiling shall be equal to a type equal to
trade term R-H
37. STAIRS
a. All interior stairs shall be factory assembled. Basement and
cellar stairs shall have pine treads 5/4" x 10" and a w6od
handrail on 2 x 4 supports. The risers shall ~e of clo~ed type
and shall be pine which shall be carried on stringers 6f'5/4" x
d. Winder. tread widths at distance o~~ 187 from the converging e~d~'
ENERGY NOTES
a. Doors, front, side, inside to garage - U-40.
b. Windows, sliding glass doors, all glass - U-67.
c. It shall be the contractors responsibility to submit
design, and type of me'chanical systems
'38.
the size
which will be used in
sufficient detail if required by the building department.
All dpmestic HOT water 140'~ Max, setting.
Insulate all ducts and piping as required by code.
All fireplaces to be provided with damper for outside combus-
tion air 150-200 CFM. Flue to have tight seated damper max
leakage 20 CFM. "
g. Refer to detail drawings for thermal transmittance of walls,
ceilings, roofs and floors.
h. The rchmtect cmrtifies that to-the best of his knowled.ge, the
drawings confor~ 6o the N.y. State Energy Conservation Construc-
ti.on Code.
~TYPICAL LIVE LOAD S~CHEDULE