Loading...
HomeMy WebLinkAbout47930-Z SUFfOLy� Town of Southold 10/24/2022 P.O.Box 1179 cm C* _ 2-C 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43528 Date: 10/21/2022 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 50 N Sea Dr., Southold SCTM#: 473889 Sec/Block/Lot: 54.-5-22 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/22/2022 pursuant to which Building Permit No. 47930 dated 6/8/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations(non-substantial improvement)to an existing restaurant as applied for. The certificate is issued to 50 N. Sea Dr LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 22-84991 9/21/2022 PLUMBERS CERTIFICATION DATED 10/4/2022 B a iecuch ho ize gnature ,�� sUFFoc�c TOWN OF SOUTHOLD BUILDING DEPARTMENT y x ' TOWN CLERK'S OFFICE "oy • � , SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47930 Date: 6/8/2022 Permission is hereby granted to: Cliff&Phil's Lobster House PO BOX 985 Southold, NY 11971 To: legalize "as built" and construct alterations (non-substantial improvement) to an existing restaurant as applied for per SCHD Food Service approval with flood permit. At premises located at: 50 N Sea Dr., Southold SCTM #473889 Sec/Block/Lot# 54.-5-22 Pursuant to application dated 3/22/2022 and approved by the Building Inspector. To expire on 12/8/2023. Fees: AS BUILT-COMMERCIAL ADDITIONS/ALTERATIONS $1,108.80 Flood Permit $100.00 CO-COMMERCIAL $50.00 Total: $1,258.80 Building Inspector Certificate of Compliance J:-, ..... CERTIFIED E.LECTRICALANSPECTIONS,,INC., 188'`POWAVENUE, ' — �.' i; ., 's _ .'AMITYVILLE, NY:11701 = T P:,(631)'.598=:56-10— _ K I 0 3 2022' .; ;........ .CERTIFIES THAT... 101 Upon-the application of Upon premises owned by - Platinum`-East'Electric: 'Elbow-East 1320_,Kenneys.Road,, {' 5.0, N._Sea Drive: Southold_, NY 11971 ' ` Southold, NY 1;1971 . -Located at:.50,N--. Sea Drive; . Southold,;NY 11.97.1 Application Number#!122-84991 Certificate-#:'22-84991 -ElectricailLicense M 34091-ME Section: -,Block-,- -Lot: ,Buildsng Permit M-47930'. ; Described,as a Commercial Building occupancy,,wherein the premises electrical,system consisting of electrical,-devices_arid wiring;`described b'elow;'located in/on the premisesat: Interior Renovation '.. A visual,inspection of the premises electrical-system, limited to.electrical devices and wiring to the extent detailed`herein, was,conducted in accordance with-the requirements,of the applicable code'/or standard promulgated-by the State of.-Now York, Department of State Code-Enforcement and Adrriinistration,"or other authority having-jurisdiction; and found to be in compliance therewith = - on the 21 st day of September 2022 Name. _ -QTY- . Duplex Receptacle,-20Amp,A20V .,9= Switch:-20 Amp, 1'20V 4; .-4FT-LED Fixture-'20Amp; 120V 2 , PFI Receptacle-:20.Amp, 120V 6`" - - Power Panel-60 Amp_, 246V,,12 Circuit -1 ,Comb Emerg%Exit-,20,Amp, 120V 4 Motion.Switch -20 Amp;'120V '.3'. .Hand Dryer-'= 20'Amp,.120V:-_ 2 " Showcase-Circuit-.20 Amp; 120V.. Electrical Inspector:Antliony,,GiordanoNz ; `\N 4s� a!APPROVED o _ 3. = -This certificate,is not,valid',unless raised seal is present. ; Certificate of Compliance .... ...................................................... ........................................... ........... ..........................- - CERTIFIED-ELECTRICAL-INSPECTIONS,.INC.:: _ 188'PARK AVENUE ..AMITYVILLE, NY 11701. . _ ...................................................... P:;(631) 598=561:0 :........:....:........: .. i ERTIFIES THAT . -Upon-the'application of Upon premises owned"by" Platinum East Electric', Elbow East 1320 Ken;neys Road. _ 50 N. Sea'Drive ' : . Southold_, NY 11971, ' ,?,Southold; NY'11971., Located at:-50 N:Sea Drive, = Southold, NY 11971 - Application'Nuinb`er#f22-84991 Certificate#:,22-84991 Electrical License#:_34091-ME Section: Block: :,Lot:; Building Permit#: 47930. Names QTY.- _ Feet Multi- Outlet,System-'20 Amp, 120V 14 ; _ Fixture'Outlet-20-Amp,.120V 4 ; Recessed.Hi-hat Fixture''20 Amp, 120V'.- 6 _ 'Electrical lnspector:'AnthonyGiordano iz APPROVEDIS= A. This certificate is not valid unless raised seal is'present. �Q��pF SO!/T�OIo Town Hall Annex Telephone(631)765-18( 54375 Main Road K 1 Fax(631)765-9502 CA F.O.Box 1179 Q Southold,NY 11971-0959 a g � psi; BUILDING DEPARTMENT "� l�' l TOWN OF SOUTHOLD OCT 7 2022 f'iJiLarvG r« • —_� TOi" 3-- CERTIFICATION Date: /® Building Permit No. Owner: J/'k le 11JI I f ;t'1 S-In n (Please print) Plumber. 0-Cf 11° G c•� �� (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. umbers Signature) Sworn to before me this day of&A 6e-r , 20 f SUSAN A.R17-Z0 Notary public,State e Nev'Yoric No.Oi plCj83459 oualiFed in Ce'i 1 Co1 ;2 Oornrnission�%:p Notary Public, 'J� County j 2� IV SOUIyOIo TOWN OF SOUTHOLO BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEG. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL A2® [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: 4f- tomdvt, Cv--O-v,> Jmw\ 56- 10�& �L&n OIC rp pmv rJ t>zwt \'�'4hAk� S:o'ml�ft- XA�YKMAOA " - DATE 11 I of7 0.1) INSPECTOR .� � \\ SOUryo� * TOWN OF SOUTHOLD BUILDING DEPT. �ycourm, 631-765-1802 IN SPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKIIN�N(G [ ] FRAMING /STRAPPING [ FINAL (.oM/Yl , �1l/"l� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL rk &v cov � _'�q Ida, wvx wy r+ T�ik' n(. vw-ib-t . vf _V DATE INSPECTOR / OF SOpI k�� how O� # TOWN OF SOUTHOLD BUILDING DEPT. �o • �o couNr+,��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]/ROUGH PLBG. FOUNDATION 2ND V INSU [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Alf-OAA 1 Ae-2 � i � 40 U IU6 a czyolz_ DATE Y� INSPECTOR - �14 67� pF SOOT >0 (-/T ' TOWN OF SOUTHOLD BUILDING DEPT. �o • �o 631-765-1802 INSPECTION [ ] 'FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] .FRAMING /STRAPPING FINAL [ ] FIREPLACE &CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: reg ,41-AtL^ ACC60P ICC aC ori ge-z< d0�N� /2,4re- Oyf- 6411252. Pz/,,✓,5 . DATE INSPECTOR fs INSPECTOR Suffolk County Department of Health Services Bureau of Public Health Protection Plan Review Unit 360 YaphankAve,Suite 2A Yaphank,NY 11980 CERTIFICATE OF APPROVAL CONSTRUCTION OR ALTERATION OF-FOOD SERVICE ESTABLISHMENT Approval is issued under the provisions of Article 13, Section 1304 of the Suffolk County Sanitary Code Establishment Name Establishment Address Little Fish 50 North Sea Dr Southold, NY 11971 The Followinq Conditions Apply • This approval does not constitute approval by any other state or local agency • This certificate is not a permit to operate a food service establishment.The operator must call the Department at 631-852-5873 to arrange an inspection of the completed construction prior to operation • The proposed construction is in conformity with the plans and specifications approved by the Department • Approval is based upon the application,plans and menu provided. Any changes require written approval from the Department of Health Services • This approval is valid for 2 years.Extensions may be granted upon written request to the Department prior to the expiration date • The applicant shall comply with the following amendments to the plans and specifications: A) Provide dual drainboard space for bar 3 bay sink (glass rack may be used for clean glasses B) Provide splash guard on bar hand sink C) Provide self-closing toilet room door D) Provide spill lip on bar E) Provide mop sink with mop hook above F) Provide lockers/hooks for employee personal items Issued for the Commissioner of Health ,4w4aW4'j&?Doquae& Designated Representative 6/7/2022 CUSTOM HOMEBUILDERS Thoughtfully Craft®d, 14on®stly Mad®" Confidential Bid Proposal Alterations Presented: May 6th, 2022 Prepared For: Little Fish Restaurant Location of Property: SO North Sea Drive Southold, NY 11971 Elevations,Courtesty of.Ural Talgat,Architect North Fork Woodworks, Inc.810 Traveler Street,Southold NY 11971 Tel: 631-298-7900 Email:info@nfwoodworks.com CUSTOM HOMEBUILDERS TAoa004 0*14 How*Made WELCOME North Fork Woodworks would like to thank you for the opportunity to bid on your new construction proiect. We have built countless additions, renovations and new homes on the North Fork. Our business was built by"word of mouth" and referrals from satisfied homeowner's for whom we have worked. We pride ourselves on our reputation for quality and outstanding customer support. Should you have any questions whatsoever, require additional clarification or need to reach us for any reason, please feel free to contact us at anytime. At NFWW,our most important responsibility is to help our clients realize their vision, and put them at ease throughout the entire construction process. We're always here to help! Sincerely, Scott, Kyle, Rachel and The Team at North Fork WoodWorks, Inc. j a North Fork Woodworks, Inc 810 Traveler Street, Southold, NY Tel: 631-298-7900 Email: info@nfwoodworks.com CUSTOM HOMEBUILDERS noughtru4 GvW Horm*Made' Our Approach At North Fork, we put a lot of thought into the seemingly little things. Why? Because those are the things that you'll notice when you're home is no longer a wish list, a collection of architect's plans or a construction site but instead, the place where you actually live. Our approach is simple: we look for every decision we make today. Thoughtfully Crafted. As experienced craftsmen,we know your home will wear in.At North Fork,we don't just build your home for the day it's delivered, but instead,for all of �. those years you'll be enjoying it. To ensure that you're satisfied i for the life of your home,we take care to pay special attention to all of thesmallest detailstoday,so you won't have to think about it all,tomorrow. Honestly Made h When you work with North Fork, you work with a special group of skilled craftsmen who put quality ahead of size, people ahead of profit, and what's right over what's just enough. Because we take a client-forward approach, honesty and transparency serve as guidelines for every aspect of our process. "These guys are truly outstanding,so accommodating,they renew one's faith in what good people are all about" —Regina E,. New Suffolk&NYC North Fork Woodworks, Inc. 810 Traveler Street, Southold NY Tel: 631-298-7900 Email: info@nfwoodworks.com CUSTOM HOMEBUILDERS Thou¢M(oty CwW HC=*Made Sample Letter of Recommendation LESLIE KANES WEISMAN ]LESLIE KANES WEISMAN September 21,2010 To Whom It May Concern: If you are particular about design details,craftsmanship,and working with trades who actually deliver what they promise,then you should seriously consider North Fork Woodwoxks,Inc.for your construction project.After obtaining several bids from reputable contractors,speaking to their references,and personally inspecting work completed by each,I recently signed a contact with Kyle Schadt and Scott Edgett.They were neither the highest nor the lowest estimate I received,but they stuck to their price quote and they more than met my expectations.They started when they said they would,showed up every day,and stayed on my job full time until it was completed to my total satisfaction,and theirsl They didn't"cheap out"on materials or hit me with price over runs.They were always accessible,answered my calls quickly,and were a pleasure to work with.Moreover,every member of their skilled construction crew was courteous and professionally behaved. Unexpected complications arise on most jobs.Mine was no different.Kyle and Scott handled these situations by carefully considering a variety of possible approaches and,as importantly,by immediately informing and involving me in decisions before,rather than after the fact.The outcomes were always positive. They stand by their work and they did not hesitate to return to my job to make adjustments, even after they had been fully paid. On a more personal note,Kyle and Scott were both born in Southold Town,are raising families here, and are in business for the long haul. If you believe in supporting our local people and economy as I do,but would never sacrifice quality in the process,North Fork Woodworks,Inc.will give you a competitive price and an expert job.I recommend them without reservation. Sincere Leslie Kanes Weisman Professor Emerita of Architecture 10720 Soundview Avenue-Post Office Box 1280-Southold,New York 11971 E Mail:weismanQnorthfork.com Phone/FAX:631765-8174 North Fork Woodworks, Inc. 810 Traveler Street, Southold NY Tel: 631-298-7900. Email: info@nfwoodworks.com Table of Contents CUSTOM HOMEBUILDERS Thoughtfu0y Cmfh4 Honestly Mode Section Page General 1 Demolition 2 Du m psters 3 .................................................................................................................................................................................................................................... Rough Carpentry 4 Exterior Finish Carpentry 5 ---------------- Windows & Doors 6 Roofing 7 .................................................................................................................................................................................................................................... Siding 8 -prum ing Electric Insulation 11 Drywall 12 Interior Paint 13 Exterior Paint 14 Interior Trim 15 Tile/Flooring 16 Finish Hardware 17 ADA Upgrades 18 Breakdown 19 Total Investment 20 F= General N Job site shall maintain cleanliness and organization throughout the total project. N Meetings will be made available as needed by architect, homeowner and designer. N All necessary inspections to be arranged by NFWW. N All job scheduling to be updated monthly and available for viewing at request. N All insurance certificates to be present at contract signing. N Portable field toilets will be available for the entire project and will maintain sanitary conditions at all times. —Job will be left broom swept on a daily basis. N North Fork Woodworks shall coordinate work of all subcontractors and building trades to facilitate smooth and timely completion of the work. �I LABOR $2,500.00 SUB $690.00 MATERIAL TOTAL OPJl 1-General F= Demolition N Remove existing track ceiling. N Remove existing windows per plan. N Remove set up area finishes. N Remove existing bar. N Remove carpets/flooring. N Remove existing TV's. N Remove shelving behind bar. IS Mor"Alm- LABOR $3,240.00 SUB MATERIAL TOTAL $3,240.QJOI 2-Demolition Dumpsters N Dumpsters to be supplied by local recycling sanitary company. N Dumpsters are for all rubbish, and leftover materials. N All dumpster surroundings will maintain cleanliness. N All dumpsters to be dropped off in a parallel position to the best of our abilities. N All material to be separated and recycled as per the sanitary companies request. Note: All dumpsters are set as an allowance; this price is for budgetary reasons only. N By Others. I LABOR SUB MATERIAL TOTAL 0QJl 3-Dumpsters Rough Carpentry N All rough carpentry for Little Fish Restaurant, as per plans by Ural Talgat, Architect, plans dated 4/1/22. N Install new steel header for wall opening. N Frame new 2x6 wall to receive new windows by bar area. N Shim ceiling for drywall. N Blocking needed for handrails. N Frame new bar. IBM LABOR $6,000.00 SUB MATERIAL $7,475.00 TOTAL $13,475.0Ojl 4-Rough Carpentry Exterior Finish Carpentry N Supply and install new window casings using composite 5/4 x 4 screwed and plugged. LABOR $4,320.00 SUB MATERIAL $2,645.00 TOTAL $6,96LOO 5-Exterior Finish Carpentry F= Windows & Doors Item Qtv Operation uocaaon LL— 100 9 Loft-Right None Assigned ROSize.Srx48112" UnitSize-56112"x48" Common Frame CW14,Unit 400 Series halo CasemenI,White Exterior Frame,White ExteriorSash/Panel,PinewlUnfinished Interior Frame,Unit r 1:Left,Unit 2:0 Se Hinge n C Wash Mode,Dual Pane Low-E4 Standard Series Argon FBI Traditional Trim Stop Prc01e Stainless h _Glass!Gn719 Spacer,Classic Series,White,Corrosion Resistant Hardware,White,Full Sween,TruScene a Hardware.PSC Classic Series White PN:1361536 Insect Screen 1:400 Series Tarin Casement,CW14 FUR Screen TruScene White PN:1344172 Hardware:PSC Classic Series White PN:1361536 Insect Screen 1:400 Series Twin Casement,CW14 Full Sween TruScene White PN:1344172 Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area(Sq.Ft) Comments: Al 028 0.32 YES — Al 20.0197 43.1480 5.99870 B1 0.28 0.32 81 20.0197 43.1480 5.99870 Item Oty Operation Location 200 3 Left-Stationary-Right None Assigned I� \� ROSize-72318"x49112" Unit Size=71718"x 48" f / Common Frame 9 \ % C34,Unit,400 Series Triple Casement,White Exterior Frame,White Exterior Sash/Panel,Pine w/Unfnished Interior Frame,Una 1: Lek,Unit 2 Stationary,Unit 3:Right Hinge with Wash Mode,Dual Pane Low-E4 Standard Series Argon FIII Traditional Trim Stop —Profile Stainless Glass/Grille Spacer,Classic Series,White,Corrosion Resistant Hardware,White,Full Screen,TruScene Hardware:PSC Classic Series White PN:1361536 Insect Screen 1:400 Serres Triple Casement,C14 Full Screen TruScene White PN:1344171 Hardware:PSC Classic Series White PN:1361536 Insect Screen 1:400 Series Triple Casement,C14 Full Screen TruScene While PN:1344171 Unit# U-Factor SHGC ENERGY STAR Clear OpeningNnil# Width Height Area(Sq.Ft) Comments: Al 0.28 0.32 ~YES Al 14.4230 43,1480 4.32170 B7 0.28 0.32 Cl 14.4230 43.1480 4.32170 C1 0.28 0.32 IA,it LABOR $4,320.00 SUB MATERIAL $20,605.70 TOTAL $24,925.7pjl 6-Windows & Doors F=- Roofing N Roofing repairs by others. LABOR SUB MATERIAL TOTAL $O.gojl 7-Roofing Siding Ji N New T-111 at new wall by bar approximately 5 sh eets. I LABOR $2,160.00 SUB MATERIAL $782.00 TOTAL $2,942.QJOI 8-Siding Plumbing N Re-hook up existing bar equipment. N Re-set existing toilet and sinks in bathrooms. N Fix rotting waste line from bar. N Fix leaking roof drain. N Re-install existing dip well in prep area. LABOR SUB $8,625.00 MATERIAL TOTAL $8,625.00 9-Plumbing Electric A renovation allowance of$14,800.00 has been allocated for: N New bar layout and new header. N New high hats in dining room. N All new devices and plates. Note: Smokes and carbons by others. Note: This is an allowance only and to be billed to owner accordingly at a later date. LABOR SUB MATERIAL TOTAL $14,800.00 10-Electric Insulation N New open cell spray foam insulation 8" R-32 rafters in dining and bar area only. LABOR SUB $5,579.80 MATERIAL TOTAL 5 579.80 11-Insulation FE777 Drywall N New 5/8" drywall on ceiling of dining area and prep area with (03) coats spackle. N Patch walls and skim coat as needed, prepped for paint. AI,'Iawn. LABOR SUB $11,385.00 MATERIAL TOTAL $11,385.00 12-Drywall Interior Paint N By others. LABOR SUB MATERIAL TOTAL $0.201 13-Interior Paint Exterior Paint N None at this time. LABOR SUB MATERIAL TOTAL OQJI 14-Exterior Paint Interior Trim N New window casings on all new windows. N New shoe base after floor. N New bar top/shelfs by others. N New cable rail at upper dining room. N New doors as needed. LABOR $8,640.00 SUB MATERIAL $7,015.00 TOTAL $15,655.00 15-Interior Trim i f Tile/Flooring N By owner. LABOR SUB MATERIAL TOTAL $0.00JI 16-Tile-Flooring Finish Hardware N An allowance of $1,000.00 has been allocated for door knobs and hardware material. This is an allowance only and to be billed accordingly to owner at a later date. LABOR $1,000.00 SUB MATERIAL TOTAL $2,000.Opjl 17-Finish Hardware ' r ADA Upgrades N (04) NEW 36T DOOR-WITH PUSH BARS WITH ADA SILLS. *Mat ial: 15,180.00 *Labor: 4,320.00 *Total: $19,500-00Z N RE-BUILD ENTRY RA FR'M Dl`NING ROOM TO E NTRY. *Material: $207.00 *Labor: $1,080.00 *Subcontractor: $13 R7 , *Total: $1,425.00 N BUILD NEW 6' SECTION OF BAR LOWERED TO ADA COMPLIANT. *Material: $1,069.50 *Labor: $1,440.00 *Total: $2,509.50 N REMOVE EXISTING SET UP AREA DOUBLE DOORS AND CREATE 40" TRIMMED OPENING. *Material: $126.50 *Labor: $720.00 *Total: $846.50 18-ADA Upgrades ' Y } Page SUB Material/Subs # Description MATERIAL CONTRACTOR 15% LABOR + TOTAL 1 General $600.00 $90.00 $2,500.00 $3,190.00 2 Demolition $0.00 $3,240.00 $3,240.00 3 Dum sters $0.00 $0.00 Rough 4 Carp entr /Framin g $6,500.00 $975.00 $6,000.00 $13,475.00 Exterior Finish 5 lCarpentry $2,300.00 $345.00 $4,320.00 $6,965.00 6 Windows & Doors $17,918.00 $2,687.70 $4,320.00 $24,9 5.70 7 Roofibg $0.00 0.00 8 Siding 680.00 $102.00 $2,160.00 $2,942.00 9 Plumbing $7,500.00 $1,125.00 $8,625.GO 10 1 Electric $0.00 $14,800.00 it Insulation $4,852.00 $727.80 $5,579.80 12 Drywall $9,900.00 $1,485.00 $11,385.00 13 Interior Paint $0.00 $0.00 14 Exterior Paint $0.00 $0.00 15 Interior Trim $6,100.00 $915.00 $8,640.00 $15,655.00 16 Tile/Flooring $0.00 $0.00 17 Finish Hardware $0.00 $1,000.001 $2,000.00 TOTALS $33,498,00T $22,852.00 $8,452.50 $32,180.00 + $112,782.50 19-Breakdown � t Tota I I nae-�sti leant :Ng Allowances: $15,800.00 Total Investment: $112,782.50 All material is guaranteed to be as specified, and the above work to be performed according to the drawings and specifications submitted for above work and completed in a substantial workmanlike manner for the sum of $112,782.50 VIS Me7sEr Respectfully submitted by North Fork Woodworks. Any alteration or deviation for above specifications involving extra costs will be executed only upon written order and will become an extra charge over and above the estimate. All agreements are contingent upon accidents or delays beyond our control. The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be Date Signature Signature 20-Total Investment o w ♦ �' i f/ �` SMR. / ♦ ."� i-<- . �•� Li 1f IS *�� H♦ y.� ♦ d� S /• yy ♦i kt 07 - I r"# 4te;. r. � �#� •,x,..�.I.'. ,� �.�ter,.::,. �;,.F � �:;� k �51 � F i f <,a��.. � she $ la } f ''�,� ,. .v�fu�'' 4 "3e♦ -`' �;?+. �;- k• _ ��i� +j � �� i '� �'' •rte "'��t,'k Alr� -, 44uutt t a _� � r _ w�a•y�11�7A'S:;lr r, Z��s.� ,ta �f. � -fir'.. ' —. r'•� �►^'� Yi� � �n AMC a'. S �. � � � �� •.�� .fir. t r � _ r ir'�1 �4 pit r - �� Y4 _�. tom„ "� ' ��N a ��'hr--•'� �,,F.. . r z �•�k( i L yds' '73 1p*IrAir, i •� ..: .J*` <.,,,,dp. £ r f , f ,. *;tow - J 1, �• � - r r , E e • f "• �rrr,fff 1HP+" a y •♦ ^.� rh `k!a .'' ii ( �•. A�' .fie It J ^'�sq �' � ��. '�• t' t •;til' •v b � � �af• =•d t.. r � 'A ^ � ' �: �`�• ^ ti`s__��Jy, .- ,�.#`��` •, -. .. '&. Ot ♦ .. f �-.,- of-1>'f`f�!•r• r: , • .(' in 'v �'�'..,y � r f� r - - �a ,lit',° ti�_����° ,• `,ter 41 ' - - i Ab NR ;. / %. �- �. stir�`''' �'w,�,: 'tom: _ _.� p, {•..I�r.: �"� ��i' " max. � ��4� �' �`�., - St, C� `'r'`.y;" •.. �'/� `� ��. � ,�... r. y �� � "off w '�,� ,i <, - � � �•- � `-� / � a Gj NO SMOKING .•� r �T 1 iT i I F 1. TQv,, ; �" Ir 1 f flow �P�4 i i �S 1 lS1tA Y'l1lpy � j �` � �,y �I•I W h ♦ _ + "y r q .. op i k T I� 44 VV-34;o • ,fir _,`. � �. � , r•- � .•/ , w r � v t� t' fir ,yr'•_ . ♦ • i. f f , / f •' 4 jdA -~ 4' • + N4 iIlk �,- Al } 3..i ` e mq �" -'ate'-.�I. ' .`�� • f .�,�';1 17\ '•mow.-�.Y +,• '� r , f �. I+ i•. le IVA rt �•` stir. ,. x. K / i "„��_ 1 /�' �' � `� �/ �� 1 I �•1 _' I � «� �..� -� � �� _- ,� :.r_y ,. �� r .�k'�..r�y.` - __ � r. -p� ry« . _. ., r 'r - �, i �� ! 4 w .,� � I. ���� � � � ;.' t „� � -� i '� �, :'s J•^` .� . t r ,� f � 1 �„ lr , ~' b�► i �����"�;�}��{•* , J �•!0 rte+ �Ax Ab MAj �/rt ' 4pgo Y • '', ai' '43- ,R• '�/1%01. ' + "' '-;err.► � �'. .e ♦ i •. '- A _ ks x t. } t � f t 8 t.. { 1 ; L t r� r s rti Y �4 r P Ali • y�, i'lilt:, a w.. ! 7 l f f y r �w,� r T. lot / ����.. x•• Ae If 46.. Ike-1 fi iR A PLA OL ,ice, .. �/ /� • ` • ` '� set ,•,` _ . 1�t�''/"�'" ' ,� �-:.. /� � �A � 4 � *�� �!((j�A,.,•Y - Irl Ar Af I-X-4-51, tom,✓/r/�f �I �� 'fd - *x� � s� � - � I-' ~ , r t ,.�il�'r�1.. :f°f/A.._':, :�i7...� l � `r- :l ;:� '�•- �1 ,:fi.. � .rte::.-.1 r _ t r4-0 wj'IVe7 4 •' fi `4.a � 'j;yc� kip ell �MhWly��f� � " Y ' � 4 n. �F •y���T4 74k 1 A' p SJa Tf w 4.4 AdW AO, ee t or t WOL V4 N� •� ,r.�:.?S•'• rhe �. a - 10 r ,/" ( ,,fr.i ^rte r.. - �r j1 �• i, 0 � �`�,�,. � �� s t ,1y yeti ' r s •��� � ' �. .'! y.�►din f ° � �'^r r ` v¢.:A t � it r r .w sir' fr �f .. � I A �Sf i .. _ Y::.. 5.,. . _ s ���� �� �,.-..., v..., i n, :d . _ � .� r •.0 ate:_ ,� -; a; > . + s�+w.. ".�".�.,:� , , . . .._. .r "';rY �. � .,�.,ate .. '. .:�y.yYLw C9 Na _.... � a � ^`tet fr. a \, .. _ � c .. ., 1. i �k ._ ., � ..4 � h'. 1 *1- _ P,, r u� II i G� Y M ,, w r aw'-AMIA .t 'Rt�� i1L. - EL1 Insulation Certificate CONSTRUCTION This form must be filled out and posted to comply with building code requirements. Meets IRC Chapter 11 Energy Efficiency Requirements and IECC Chapter 4, Commercial Energy Efficiency Requirements. • Open Cell 0.50 lbs/ft3 • Closed Cell 2.00 lbs/ft3 • DC-315 Fire Retardant Thermal& Ignition Barrier Consult International Building Code, Chapter 26-Plastic and International Residential Code (IRC) R316 Foam Plastics for specific requirements.The spray polyurethane foam insulation system(s) has/have been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of: Area Insulated Aged R-Value Thickness Main House: Flat Roof R-32 At 8 inches Main House First Floor R-22 At 5.5 inches Cellar Room:Walls R-32 At 8 inches Cellar Room: Ceiling R-22 At 5.5 inches —Nominal thicknesses are representative of field,spray-applied foam material. In addition, R15 ROXUL insulation to ductwork framing box as per inspector requirementfor fire retardant compliance. Jobsite Address: 50 N Sea Dr,Southold, NY 11971 Date of installation: 07/22/2022 Contractor: Eli Construction Services INC. Phone: (631) 869-5171 j 1490 William Floyd Pkwy#109 Shirley,New York 11967 (631)869-5171 ELI info@eliconstruction.com CONSTRUCTION If,-? � 3 D SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES FOOD ESTABLISHMENT INSPECTION REPORT 1P 360 Yaphank Avenue,Suite 2A Yaphank,NY 11980 Public Health Tel: 631 852-5999 Fax: 631 852-5871 Facility Number I FA Program Facility Name `b, t Facility Address d� CVT 1 EMAIL /nJ , i Permit Holder Permit Holders Address �jnJJ r Il tb? V 1 Responsible Party � j I, '; Sr � Inspector's Name I' 111 I Activity Code ]IJ Time of Inspection ' ; Am Pm Inspection Date /�/ n,2 Reinspection Dale art sK Factors and Public Health INtervOntions Item# DESCRIPTION OF VIOLATION: Corrective Action/ Correct By Date 0 , Qa ,. */1 /11,P /2/1 A n +_ ? 1 'il f / 411, P11.4r r' � y ' a /Z I Part 2: Goo etasPractices Item# DESCRIPTION OF VIOLATION: Corrective Action/ Correct By Date t , f 1AP d I-A ? R " 'i D JI,� I�1 n OT TOWN OF SOUTHOLD THE ITEMS NOTED ABOVEARE VIOLATIONS OFAPPLICABLE RULES AND REGULATIONS FOUND DURING AN INSPECTION OF THE OPERATION OF THIS ESTABLISHMENT WHICH MUST BE CORRECTED AS INDICATED.FAILURE TO COMP MAY RES N THE INITIATION OF LEGAL ACTION AGAINST THIS ESTABLISHMENT AS PROVIDED FOR IN ARTICLES 2 AND 13 OF THE SUFFOLK �U SANITARY DE INCLUDING A HEARING,FINES AND POSSIBLE SUSPENSION OF YOUR FOOD OPERATION. Signalu of Per eiving Re rt Title Signatu,e of Sanitarian San ID# Insp.Status Page 1 of f 18-2041.05122 Nunemaker, Amanda From: McDonnell; m� awn a <AmandaF DMell@suff:ollkcoun,ty,�ny. ou> Sent: a nes ay,June 8, 2022 9:01 AM To: 'Arden'; Nunemaker,Amanda Subject: RE: Little Fish W,.ast_ew�ter ,.a�agernen�t ppr.� is riot requ`i`red. Amanda We onneff Associate Public 9feafth Sanitarian Training and cPfan Review unit SuffofkCounty Department ofMeafth Services 360 TaphankAve.,Suite 2A Taphank 3Y 11980 v- 631-852-5842/852-5999 Of 631-852-5871 TAX Please use the following link for the Suffolk County Health Department website: https://www.suffolkcountyny.gov/PHP Please use the following link to register for classroom training: https://apps2.suffo[kcountyny.gov/health/foodtraining/ Please use the following link to register for the online course: https://apps2.suffolkcountyny.gov/Health/FdOnline/default.aspx Please use the following link to register for the online limited course: https://apps2.suffo[kcountyny.gov/Health/Limited FdOnline/default PRIVILEGED AND CONFIDENTIAL-INTEROFFICE/INTRA-AGENCY COMMUNICATION-NOT SUBJECT TO FOIL DISCLOSURE-NOT FOR DISTRIBUTION CONFIDENTIALITY NOTICE:This electronic mail transmission is intended only for the use of the individual or entity to which it is addressed and may contain confidential information belonging to the sender which is protected by the attorney-client privilege.If you are not the intended recipient,you are hereby notified that any disclosure,copying,distribution,or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this transmission in error,please notify the sender immediately by e-mail and delete the original message. From: Arden [mailto:arden.gardell@gmail.com] Sent: Wednesday, June 8, 2022 8:38 AM To: Nunemaker, Amanda; McDonnell, Amanda Subject: Re: Little Fish ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. Hi Amanda,the health dept will be emailing to clarify it is not required. Her email is attached above for confirmation. Arden Sent from my iPhone 1 5/4/22,2:40 PM Gmail-Elbow East,Southold NY ft� As ria i l Arden Gardell-Gross<arden.gardell@gmail.com> Elbow East, Southold NY Spooner,Anne<Anne.Spooner@suffolkcountyny.gov> Mon,Apr 25, 2022 at 1:36 PM To:Arden Gardell-Gross<arden.gardell@gmail.com> Hi Arden. Sorry for the delay. I had been out all week last week and working through emails and messages now. If you are simply changing ownership of the establishment without making any changes, please complete the attached Food Establishment Permit application and submit with permit fee. If you intend to make any changes to the layout of the establishment(adding/moving/removing equipment not including replacing existing equipment with the same, such as replacing a non-functioning upright refrigerator with a new upright refrigerator in the same spot),you would need to complete the plan review package attached. Feel free to reach out if you have any questions. [Quoted text hidden] 2 attachments FOOD ESTAB PERMIT APP 0519 FILLABLE.pdf 202K Food Establishment Plan Review Guide 030821.pdf 2562K https:Hmail.google.com/maillu/0/?ik=a5e87dcflf&view=pt&search=all&permmsgid=msa f%3A1731102691934370254&simpl=msg-f%3A1731102691934370254 1/1 5/4/22,2:41 PM Gmail-Elbow East,50 N.Sea Drive 1 M G Imola I I Arden Gardell-Gross<arden.gardell@gmail.com> Elbow East, 50 N. Sea Drive Kolody, Lisa<Lisa.Kolody@suffolkcountyny.gov> Tue, Jan 11, 2022 at 1:48 PM To:Arden Gardell-Gross<arden.gardell@gmail.com>, tracey gardell <traceygardell@gmail.com>, Reina Miller <rillah725@gmail.com> Hello Arden, I have taken Anne out of the email. I would be happy to work with you on your new endeavor. Do you plan on making any changes to the establishment? Minimally you would need to submit a new application with the permit fee. I am attaching an application to this email. It may be filled in electronically, but it must be printed and signed by a corporate officer(or owner if individual ownership). We need proof of Workers'Compensation and Disability Benefits. There are specific forms that are required as proof and are as follows: 1. Workers' Compensation—Form C-105.2 OR Form U-26.3 OR Form SI-12 OR Form GSI-105.2 2. Disability Benefits—Form DB-120.1 OR Form DB-155 call 1-866-805-3630 or online at http://www.wcb.state.ny.us/. If you have any questions, please just ask. Sincerely, Lisa Kolody Senior Public Health Sanitarian Suffolk County Department of Health Services Bureau of Public Health Protection 360 Yaphank Avenue Suite 2A Yaphank, New York 11980 631.852.5838 631.852.5871 (Fax) https://mail.google.com/mail/u/0/?ik=a5e87dcf 1 f&view=pt&search=al I&permmsgid=msg-f%3A 1 721 6 85 1 3 8474351076&simpl=msg-f%3A 1721685138474351076 1/3 5/4/22,2:41 PM Gmail-Elbow East,50 N.Sea Drive Inspection reports for all Suffolk County Food Service Establishments are available to the public at: https:Heco.suffolkcountyny.gov/#/pal/search Online Class: https:Happs2.suffoIkcountyny.gov/Health/FdOnIine/defauIt.aspx Online Limited Class: https://apps2.suffolkcountyny.gov/Health/LimitedFdOnline/default Classroom Registration: https:Happs2.suffolkcountyny.gov/health/foodtraining/ V1 1� �RAT Vaccination = Freedom from COVID-19 S U F F L Help Suffolk County get back to normal COVID vaccines are safe,effective and free CONFIDENTIALITY NOTICE:This electronic mail transmission is intended only for the use of the individual or entity to which it is addressed and may contain confidential information belonging to the sender which is protected by the attorney- client privilege. If you are not the intended recipient,you are hereby notified that any disclosure, copying, distribution, or the taking of any action in reliance on the contents of this information is strictly prohibited. If you have received this transmission in error, please notify the sender immediately by e-mail and delete the original message. From: Arden Gardell-Gross [mailto:arden.gardell@gmail.com] Sent: Tuesday, January 11, 2022 1:02 PM To: Kolody, Lisa; Spooner,Anne; tracey gardell; Reina Miller Subject: Elbow East, 50 N. Sea Drive ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. Hello Lisa, https://mail.google.com/mail/u/0/?ik=a5e87dcflf&view=pt&search=all&permmsgid=msg-f%3A1721685138474351076&simpl=msg-f%3A1721685138474351076 2/3 5/4/22,2:41 PM Gmail-Elbow East,50 N.Sea Drive An;�e gave me your contact information as my family and I have gone to contract on 50 N.Sea Dr., Southold currently { operating as The Elbow East.We expect to close mid Feb.and want to be ready to go ASAP.As such, I wanted to introduce myself and start a dialogue around what we need to do for the HD. Best, Arden 1 Arden Gardell COO&Co-Founder Arden.Gardell@AlkaWhite.com www.AlkaWhite.com (917)7146865 hftps:Hmeetings.hubspot.com/arden-gardell 0 FOOD ESTAB PERMIT APP 0519 FILLABLE.pdf 202K https://mail.google.com/mail/u/0/?ik=a5e87dcflf&view=pt&search=all&permmsgid=msg-f9o3AI721685138474351076&simpl=msg-f%3AI721685138474351076 3/3 FIELD INSPECTION REPORT I DATE COMMENTS ro FOUNDATION (1ST) y -------------------------------------- FOUNDATION (2ND) IRAO Rev Lit Ja6 y va ROUGH FRAMING& y K Va'` PLUMBING C �•� �! 1 t VDVV%6 k �o � r INSULATION PER N.Y. STATE ENERGY CODE l9 Y Ow ver ojvS v Q,rv' S op ofl FINAL 0 Ritmo A� . 0 1 ADDITIONAL COMMENTS v 1 (-o {- F3P + od 5 e -a f c, Q© r 0 �3 .� 2� �•� s�� i9c�c�rrgdv� � � /LE l IdTd , bV41,L-AA0 uN r I<ige AWdt1-1&—x5, Z F4uec- OZ � Com, /1.�W10V� Z �Nk 0�7 E]ed0 (D - ��fWD !�. tiJt���A �Sa4d2S Ta 01711.1-- Gal r r+ x H x d CrJ .d H TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631) 765-9502 Date Received j I"C?('�U( �f: 'iceM� FOR R r Mf i�Mn"� PERNT . For Office Use Only PERMIT NO. Building Inspector: �:� M Applications and forms must be filled out in their entirety.Incomplete bf SOUVOLID applications will not be accepted. Where the Applicant is not the owner,an TOWN Owner's Authorization form(Page 2)shall be completed. �a�-,1;n!0tj ts2 S+, y.tib`ssv4 CC Date: March 15 , 2022 �.�.t-•� :��,ace�a�,:>:;a fV1,6 i`i OWNER(S)OF PROPERTY: Name: SCTM#1000- 54.-5=22 Project Address: 50 North Sea Drive, Southold NY 11971 Phone#: CQ II ISS-OCA S Email: Lejw1s(cossD Ou tiMC _c0v- MailingAddress: Zc- S b�e,�c 0�j� -c `,A_ l? I1K4 CONTACT PERSON: "F_� a Name: URAL TALGAT, ARCHITECT Mailing Address: 436 7th STREET, GREENPORT NY 11944 - Phone#: 631-477-8963 Email: ural59@hotmail.com DESIGN PROFESSIONAL INFORMATION: Name: URAL TALGAT; ARCHITECT Mailing Address: 436 7th STREET, GREENPORT NY 11944 Phone#: 631-477-8963 Email: ural599hotmai1.com CONTRACTOR INFORMATION!-:- Name: NFORMATION!'=Name: North Fork Woodworks Mailing Address: PO BOX 1407 Southold NY 11971 Phone#: 631-298-7900 TErnali: build @ nfwoodworks.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition' BAlteration []Repair []Demolition Estimated Cost of Project: ❑Other $100,000 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed'from premises? ❑Yes ®No - 1 - - PROPERTY INFORMATION Existing use of property: Restaurant Intended use of property: Restaurant Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes B No IF YES, PROVIDE A COPY. ❑ The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, - additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.' Application Submitted By(print name): �` ;PeJ /f-7 BAuthorized Agent DOwner Signature of Applicant: Date: 7 1�o2 STATE OF NEW YORK) SS:jj COUNTY OFrT��IL} Ural Talgat being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are trueJto,the best of his/her knowledge and belief;and that the work will be performed in'the manner set forthi'in thle application file therewith: Sworn before me this l day of 20 02 NotaryPublic LAUREN M.MCKISSICK Notary Public,State of New Yodt No.01 MC6342308 Where,the a is not the owner Qualified in Suffolk County ( licant p p � ) Commission Expires May 23,2024T• I, r GXDQ55- residing at (i O 5 � Q I C. d , i /C1 S47 do hereby authorize U► r to apply on my behalf to the Tow of Southold Building Department for approval as described herein. 3 SAO Own Ignature _ . Date . a 6 id55. LQS Print Owner's Name 2 i SUT"'fjr�o� TOWN OF SOUTHOLD—FIRE MARSHAL N z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownngov FIRE'PROTECTION SYSTEM PERMIT Date Received APPLICATI®N a For Office Use Only �n PERMIT NO. J Building Inspector: ® L/ Applications and forms must be filled out in their entirety.Incomplete SEP' 1 5 2022 applications will not be accepted.WORK IS NOT TO BE STARTED prior to the approval of plans and issuance of a permit. BUILDING DEPT. TOWN OF SOUTH&L) Has a building permit been obtained for this project? Yes ❑No If yes,building permit# Date: as- PROJECT INORMATION: Project Address: So �0-sAh D` SCTM# 1000- City: 'Jv.. c �DY n Zip: CONTACT0,\-)V I's INFORMATION: Name: 0,C_)V 1. Mailing Address: KY) PY I '1 6Phone#: ��`_ d��_ 4�� � Email: �1�,�-- Preferred contact method(select one): ❑Phone XEmail CONTRACTOR INFORMATION: Name: SS'a \ C Contractor License Mailing Address: fAve Phone#: (D 31_ a��_ ` 0 O Email: SCOPE OF WORK: Occupancy Description: Assembly ❑Business 11 Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑ esidential ❑ Storage Description of Work: �X�S m KJ A X\ A no maz XP ❑ Ne System XExisting System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑Fire Pump ❑Protected Premises(local) Wet or Dry Chemical/Clean ❑Supervising station A nt Number of sprinkler heads: ❑Central Station ❑Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): f Check Box After Reading: I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on h greement to conform to all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee,of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): GhAuthorized Agent ❑Owner Company(if applicable): Applicant Signature: UAM Date: $ a FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the'town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: Check No.: FM: Permit No.: Date: Exp.Date: TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone(631)765-1802 ht s://w-vvw.southoldtownn . sati, ECEHE JUN 0 8 ?n?g Floodplain Development Permit AppliCan PROPERTY INFORMATION: Flood Zone: AE (EL 12) FIRM Panel: 36103CO154H SCTM#?dit-0 15iS2 Address: 50 North Sea Drive, Southold NY 11971 city: Southold zip: 11971 CONTACT PERSON: Name: Ural Talgat Phone#: 6314 778963 Mailing Address: 436 7th Street Greenport, NY 11944 PROJECT DESCRIPTION: Interior renovations to an existing restaurant SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity ❑Residential(1 to 4 families) ❑New structure ❑Residential(more than 4 families) ❑Demolition of existing structure ❑Combined use ❑Replacement of existing structure ©Non-residential ❑Relocation of existing structure R Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) ®Alteration to existing structure ❑Manufactured Home ❑ Other: ❑Located on individual lot ❑Located in manufactured home park SECTION B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material' ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction 0 Fence or wall construction ❑Watercourse alteration(attach description) EJ Excavation (not related to a structured development) ❑Other development not listed(specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until permit is re-issued.Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): Ural Talgat Signature of Applicant: Date: 6_8_2022 � fFpl,�c BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 1p� Telephone (631) 765-1802 - FAX (631) 765-9502 roper.richert(&-town.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION 'REQUESTED BY: kellg Date: Company Name: — — RE-CrOff ;(J . Name: License No.: 3 Ya / email: u. ► y"eu si.2 Ge Address: 3 — l— /2 vvcD 57 Phone No.: - JOB SITE INFORMATION: (All Information Required) Name: Lint-' -)5t4 aS So jU6tZTff SF,4 fig LL Address: A o2 S'a✓�l 0 ca Cross Street: Phone No.: Bldg.Permit#: 99 9 3 D email: JA f 1nu a�-ea&1 q7v u 0Q.( Fax Map District: 1000 Section: 5 Block: 5 Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) A a Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information•. (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals , 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION /^ Request for Inspection Form'As y v - : ` Fir. .�.......... ... .. ... _ �+- y� •i t - -���li��x��. l :7 + r PA , IP 77 .. .:�.''r..: •:. �:.. ,:' .9ry_'�_ -2oI}.x_20+� �2Z+- : .20,. ' tt` •��O.PO'i�f3"�-tiDl'I'IDI,IS- - 4,F��:.. > . E �'�� � � :.W'.Le�T plNtNe S4�+A4GK;'.SPhG� . . �..;.. FA. Avol ,� .... .. �..- . ' - - Tn 94 q� Alts :lY�s'f 9,�vy.��ZDPGtC[t(9A14'TAKLu' -" •.�. - °a - '._%f2na1 nieuEY;OF'F..3,'�rAKY1fa1G1�1..5t";:� .. .� Tit{'}^/,1 n ..' .� �� '.� � � �'f!r 'Q •nr,� r � KL I t?. 'r ei��'.+YnlaiE¢cf�'./TmS./�..• .. _ .. .. [�{���/�J4 �j/ � r ':�� : -f.'oy:Epx• 12i8.:NA• � ucK N .. . . ., , � 2 f^.:•�.�:� �.li . Gam/ o p m�rp y t , Como* &aft'own ftlo SMV . < «r��will�wrs�ws�► spoom er oft r� wr�r r1 ilr/�► gdA�1 x.rwr+;AMr s f10�� COMcheck Software Version 4.1.5.3 Envelope Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Elbow East Location: Southold, New York Climate Zone: 4a Project Type: Alteration Vertical Glazing/Wall Area: 0% Construction Site: Owner/Agent: Designer/Contractor: 50 North Sea Drive 50 N Sea Drive, LLC Ural Talgat Southold, NY 11971 28 South Delrey Rd 436 7th Street Montauk, NY 11954 Greenport, NY 11944 631 477 8963 ural59@hotmail.com Building Area Floor Area 1-Dining: Bar Lounge/Leisure: Nonresidential 279 2-Dining: Family: Nonresidential 534 Envelope Assemblies R-Value Proposed Max.Allowed Post-Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Dining:Bar 32.0 7.0 0.026 --- 0.027 --- Lounge/Leisure] Roof 2:Attic Roof with Wood Joists,[Bldg.Use 2-Dining:Family] 32.0 7.0 0.026 --- 0.027 --- NORTH Exterior Wall 1 north elevation:Wood-Framed, 16"o.c.,[Bldg. --- --- --- --- --- --- Use 1 -Dining:Bar Lounge/Leisure],Exemption:Framing cavity not exposed. Window 1:Wood Frame:Operable,Other,Operable,Operable, --- 0.280 0.320 0.450 0.583 [Bldg.Use 1 -Dining:Bar Lounge/Leisure] Window 1 copy 1:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use 1 -Dining:Bar Lounge/Leisure] Window 1 copy 2:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use 1 -Dining:Bar Lounge/Leisure] Window 4:Wood Frame:Operable,Other,Operable,Operable, --- --- 0.280 0.320 0.450 0.583 [Bldg.Use 1 -Dining:Bar Lounge/Leisure] Door 1:Glass(>50%glazing):Metal Frame,Entrance Door, --- --- 0.300 0.210 0.770 0.531 Entrance Door,Entrance Door,[Bldg.Use 1 -Dining:Bar Lounge/Leisure] EAST Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Dining: 19.0 7.0 0.044 --- 0.064 --- Bar Lounge/Leisure] Window 10:Wood Frame:Operable,Other,Operable,Operable, --- --- 0.280 0.320 0.450 0.357 [Bldg.Use 1 -Dining:Bar Lounge/Leisure] Window 10 copy 1:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.357 Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 1 of 21 Calculation.cck R-Value Proposed Max.Allowed Post-Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC Operable,[Bldg.Use 1 -Dining:Bar Lounge/Leisure] Door 3:Insulated Metal,Swinging,[Bldg.Use 1 -Dining:Bar --- --- 0.140 --- 0.610 --- Lounge/Leisure] WEST Exterior Wall 2 west elevation:Wood-Framed, 16"o.c.,[Bldg. --- --- --- --- --- --- Use 2-Dining:Family],Exemption:Framing cavity not exposed. Window 5:Wood Frame:Operable,Other,Operable,Operable, --- 0.280 0.320 0.450 0.583 [Bldg.Use 2-Dining:Family] Window 5 copy 1:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use,2-Dining:Family] Window 5 copy 2:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use 2-Dining:Family] Window 5 copy 3:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use 2-Dining:Family] Window 5 copy 4:Wood Frame:Operable,Other,Operable, --- --- 0.280 0.320 0.450 0.583 Operable,[Bldg.Use 2-Dining:Family] Door 2:Insulated Metal,Swinging,[Bldg.Use 2-Dining:Family] --- --- 0.140 --- 0.610 --- (a) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. EnvelopePASSES Envelope Compliance Statement Compliance Statement. The proposed envelope alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 2 of 21 Calculation.cck COMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Elbow East Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 50 North Sea Drive 50 N Sea Drive, LLC Ural Talgat Southold, NY 11971 28 South Delrey Rd 436 7th Street Montauk, NY 11954 Greenport, NY 11944 631 477 8963 ural59@hotmail.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Dining:Bar Lounge/Leisure 279 0.90 251 2-Dining:Family 534 0.78 417 Total Allowed Watts= 668 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Dining: Bar Lounge/Leisure(279 s" LED 1:LED A Lamp 8W: 1 8 11 88 Dining: Family(534 sq.ft.) LED 2:LED A Lamp 8W: 1 25 11 275 Total Proposed Watts= 363 Interior Lighting.PASSES Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection ecklist. Aj ,/b.-zd - ame-Title Signature Date Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 3 of 21 Calculation.cck COMcheck Software Version 4.1.5.3 Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Elbow East Project Type: Alteration Exterior Lighting Zone 2(Residentially zoned area(LZ2)) Construction Site: Owner/Agent: Designer/Contractor: 50 North Sea Drive 50 N Sea Drive, LLC Ural Talgat Southold, NY 11971 28 South Delrey Rd 436 7th Street Montauk, NY 11954 Greenport, NY 11944 631 477 8963 ural59@hotmail.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Entry canopy 2 ft2 0.25 Yes 0 Parking area 2 ft2 0.04 Yes 0 Plaza area 2 ft2 0.1 Yes 0 Guarded facility,entrancefinspection area 2 ft2 0.5 No 1 Emergency services,loading area 2 ft2 0.35 No 1 Total Tradable Watts(a)= 1 Total Allowed Watts= 2 Total Allowed Supplemental Watts(b)= 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 wafts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Entry canopy(2 ft2):Tradable Wattage, LED 1:LED A Lamp 8W: 1 2 8 16 Parking area(2 f12):Tradable Wattage LED 2:LED A Lamp 8W: 1 2 8 16 Plaza area(2 ft2):Tradable Wattage LED 3:LED A Lamp 8W: 1 2 8 16 Guarded facility, entrance/inspection area(2 ft2): Non-tradable Wattage LED 4:LED A Lamp 8W: 1 2 8 16 Emergency services, loading area(2 ft2): Non-tradable Wattage LED 5:LED A Lamp 8W: 1 2 8 16 Total Tradable Proposed Watts= 48 Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 4 of 21 Calculation.cck Exterior. • o ' Exterior Lighting Compliance Statement Compliance Statement. The proposed exterior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Chec<list. Name-Title Signature Date Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 5 of 21 Calculation.cck C®Mcheck Software Version 4.1.5.3 Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Elbow East Location: Southold, New York Climate Zone: 4a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 50 North Sea Drive 50 N Sea Drive, LLC Ural Talgat Southold, NY 11971 28 South Delrey Rd 436 7th Street Montauk, NY 11954 Greenport, NY 11944 631477 8963 ural59@hotmail.com Mechanical Systems List Quantity System Type&Description 1 HVAC System 2(Single Zone): Split System Heat Pump Heating Mode:Capacity=60 kBtu/h, Proposed Efficiency=80.00 HSPF,Required Efficiency=8.20 HSPF Cooling Mode:Capacity=60 kBtu/h, Proposed Efficiency=17.00 SEER, Required Efficiency: 16.80 SEER Fan System: None 1 Water Heater 1: Gas Storage Water Heater,Capacity:75 gallons,Input Rating:65 kBtu/h w/Circulation Pump No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement. The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. ` Name--Title Sig"tum— Date Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 6 of 21 Calculation.cck COMcheck Software Version 4.1.5.3 Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review, Complies? Comments/Assumptions & Req.ID C103.2 ;Plans and/or specifications provide all ;❑Complies !Requirement will be met. [PR1]1 information with which compliance E❑Does Not ;can be determined for the building envelope and document where ❑Not Observable exceptions to the standard are ;❑Not Applicable :claimed. C103.2 i Plans,specifications, and/or ;❑Complies ;Requirement will be met. [PR2]1 calculations provide all information QDoes Not with which compliance can be determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable ;document where exceptions to the ;standard are claimed. Load ,calculations per acceptable engineering standards and ;handbooks. C103.2 ;Plans, specifications, and/or ;❑Complies ;Requirement will be met. [PR3]1 :calculations provide all information 1❑Does Not ;with which compliance can be :determined for the service water UNot Observable heating systems and equipment and !❑Not Applicable ;document where exceptions to the ; standard are claimed. Hot water ,system sized per manufacturer's sizing guide. C103.2 ;Plans, specifications, and/or ;❑Complies ;Requirement will be met. [PR4]1 !calculations provide all information ❑Does Not :with which compliance can be ;determined for the interior lighting ❑Not Observable and electrical systems and equipment Not Applicable ;and document where exceptions to ;the standard are claimed. Information ,provided should include interior ;lighting power calculations, wattage of bulbs and ballasts,transformers and ,control devices. C103.2 ;Plans, specifications, and/or ;❑Complies ,Requirement will be met. [PR8]1 !calculations provide all information :❑Does Not ;with which compliance can be ❑Not Observable; determined for the exterior lighting ; , and electrical systems and equipment ;❑Not Applicable ; :and document where exceptions to ; ;the standard are claimed. Information provided should include exterior ! ! lighting power calculations,wattage of bulbs and ballasts,transformers and !control devices. ! ! C402.4.1 ;The vertical fenestration area <= 30 ;❑Complies !Requirement will be met. [PR10]1 :percent of the gross above-grade wall ❑Does Not area. ;❑Not Observable; ❑Not Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 7 of 21 Calculation.cck Section #. Plan Review. . Complies? Comments/Assumptions & Req.ID C402.4.1 ;The skylight area <= 3 percent of the ;❑Complies :Requirement will be met. [PR11]1 :gross roof area. ;❑Does Not ; ❑Not Observable; ❑Not Applicable C402.4.2 ;In enclosed spaces> 2,500 ft2 ;[]Complies ;Exception: Requirement does not apply. [PR14]1 !directly under a roof with ceiling E❑Does Not heights>15 ft. and used as an office, ;lobby, atrium, concourse, corridor, ❑Not Observable storage, gymnasium/exercise center, :❑Not Applicable convention center, automotive ; ;service, manufacturing, non- ;refrigerated on-Irefrigerated warehouse, retail store, distribution/sorting area, ;transportation, or workshop,the following requirements apply: (a)the daylight zone under skylights is >_ half the floor area; (b)the skylight area to daylight zone is >= 3 percent ; !with a skylight vT>= 0.40; or a ;minimum skylight effective aperture >= 1 percent. ; 1 Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 8 of 21 Calculation.cck Section #. Footing /Foundation Inspection Complies? Comments/Assumptions &Req.ID' C303.2.1 Exterior insulation protected against ;❑Complies :Requirement will be met. [FO6]1 !damage, sunlight, moisture, wind, ;❑Does Not ;landscaping and equipment maintenance activities. ❑Not Observable ;❑Not Applicable ; -C403.12.2 Snow/ice melting system and freeze ;❑Complies ;Exception: Requirement does not apply. protection systems have sensors and ❑Does Not C403.12.3)controls configured to limit service for [FO9]3v_• pavement temperature and outdoor ❑Not Observable (temperature.future connection to :❑Not Applicable ; controls. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 " Low impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 9 of 21 Caicuiation.cck section # Framing/ Rough-In InspectionComplies? Comments/Assumptions & Req.ID C303:1.3 !Fenestration products rated in ;❑Complies ;Requirement will be met. [FR12]z }accordance with NFRC. ❑Does Not ❑Not Observable; ❑Not Applicable C303.1.3 ;Fenestration products are certified as ;❑Complies ;Requirement will be met. [FR13]1 Ito performance labels or certificates ❑Does Not provided. UNot Observable ❑Not Applicable C402.4.3 ;Vertical fenestration SHGC value. ;❑Complies ;See the Envelope Assemblies table for values. [FR10]1 ;❑Does Not ;❑Not Observable; ❑Not Applicable C402.4.3, ;Vertical fenestration U-Factor. ;❑Complies ;See the Envelope Assemblies table for values. C402.4.3. 1 ;❑Does Not 4 UNot Observable; i [FR8]1 i ❑Not Applicable C402.4.4 U-factor of opaque doors associated ;❑Complies ;See the Envelope Assemblies table for values. [FR14]2 i with the building thermal envelope PDoes Not i meets requirements. ❑Not Observable ❑Not Applicable C402.5.1 ;The building envelope contains a ;❑Complies ;Requirement will be met. [FR16]1 I continuous air barrier that is sealed in I❑Does Not an approved manner and either constructed or tested in an approved ;❑Not Observable manner.Air barrier penetrations are ;❑Not Applicable sealed in an approved manner. C4b2- .2, Factory-built fenestration and doors ;❑Complies ;Requirement will be met. C402.5A are labeled as meeting air leakage :❑Does Not [FR1$]3 requirements. ;❑Not Observable I ❑Not Applicable C402.5.7 ,,Vestibules are installed on all building ;❑Complies ;Requirement will be met. [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 10 of 21 Calculation.cck Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms ;❑Complies ;Requirement will be met. C404.5.1, to pipe length and volume :❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ,❑Not Observable, ❑Not Applicable C404-.5-'' Heated water supply piping conforms ;❑Complies ;Requirement will be met. C40 .5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ;❑Not Observable; ❑Not Applicable C404.6.1, ;Automatic time switches installed to ;❑Complies ;Exception: Requirement does not apply. C404.6.2 !automatically switch off the :F—]Does Not [PL3]1 ;recirculating hot-water system or heat ;trace. L❑Not Observable ❑Not Applicable ; C404.6:3- Pumps that circulate water between a ;❑Complies ;Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls :❑Does Not that limit operation from startup to ; <= 5 minutes after end of heating ❑Not Observable cycle. ;❑Not Applicable ; C404.6.3: Pumps that circulate water between a ;❑Complies ;Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls :❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. ;❑Not Applicable C404.7 Demand recirculation water systems ;❑Complies ;Requirement will be met. [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ;❑Not Applicable ; of the water entering the cold-water piping to 104°F. C404.7 Demand recirculation water systems ;❑Complies ;Exception: Requirement does not apply. [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ;❑Not Applicable ; of the water entering the cold-water piping to 104°F. ; Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 11 of 21 Caiculation.cck Section # Mechanical Rough-ln Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 _Thermally ineffective panel surfaces of;❑Complies ;Exception: Requirement does not apply. [ME41]3 sensible heating panels have PDoes Not insulation >= R-3.5. ;❑Not Observable; ❑Not Applicable C402.5.5,. Stair and elevator shaft vents have ;❑Complies ;Exception: Requirement does not apply. C403.2.4. s motorized dampers that automatically :❑Does Not 3 3close. Refernece section C403.7.7 for ❑Not Observable; [ME3]- operational details. ;❑Not Applicable ; C403.11.3 HVAC piping insulation insulated in ;❑Complies :Requirement will be met. [ME61]?, accordance with Table C403.11.3. ❑Does Not RR!}Insulation exposed to weather is ;protected from damage and is ❑Not Observable provided with shielding from solar :❑Not Applicable radiation. C403.8.1 HVAC fan systems at design ;❑Complies :Requirement will be met. [ME65]3 - conditions do not exceed allowable ❑Does Not fan system motor nameplate hp or fan; :See the Mechanical Systems list for values. system bhp. ,❑Not Observable, ❑Not Applicable C4Q3.8.3 !Fans have efficiency grade (FEG) >_ ;, Complies ;Requirement will be met. [M 111]2 567.The total efficiency of the fan at ;❑Does Not )the design point of operation <= 15% ;❑Not Observable; of maximum total efficiency of the ; ❑ Sfan. ; Not Applicable ; 0403.12.1 Systems that heat outside the building;❑Complies ;Exception: Requirement does not apply. [ME71]2 j envelope are radiant heat systems ❑Does Not controlled by an occupancy sensing 1❑Not Observable device or timer switch. j ;❑Not Applicable C403.2.3 {HVAC equipment efficiency verified. ;❑Complies ;see the Mechanical systems list for values. [ME55]2 PDoes Not ;❑Not Observable: ❑Not Applicable C403.2.2 !Natural or mechanical ventilation is ;❑Complies ;Requirement will be met. [ME59]1 I provided in accordance with ;❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ;❑Not Observable :capability to reduce outdoor air supply�❑Not Applicable to minimum per IMC Chapter 4. ; C403.7.1 ;Demand control ventilation provided ;❑Complies ;Exception: Requirement does not apply. [ME59]1 :for spaces >500 ft2 and >25 UDoes Not ;people/1000 ft2 occupant density and ; ; ;served by systems with air side ❑Not Observable :economizer, auto modulating outside ;❑Not Applicable ; air damper control, or design airflow >3,000 cfm. C403.7.2 lEnclosed parking garage ventilation {❑Complies ;Exception: Requirement does not apply. [ME115]3. has automatic contaminant detection ❑Does Not Mand capacity to stage or modulate ans to 50%or less of design capacity. ;❑Not Observable; ;❑Not Applicable ; C403.7.6 HVAC systems serving guestrooms in ;❑Complies :Exception: Requirement does not apply. [ME141]3- Group R-1 buildings with > 50 :❑Does Not Rguestrooms: Each guestroom is provided with controls that ❑Not Observable automatically manage temperature ;❑Not Applicable 5 setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 1.3.1 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 12 of 21 Calculation.cck Section # Mechanical Rough-in InspectionComplies? Comments/Assumptions & Req.ID C403.7.4 :Exhaust air energy recovery on ;❑Complies ;Exception: Requirement does not apply. [ME57]1 (systems meeting Table C403.7.4(1) UDoes Not ;and C403.7.4(2). ;❑Not Observable; ❑Not Applicable C403.7.5 ;Kitchen exhaust systems comply with ;❑Complies ;,Requirement will be met. [ME116]3° replacement air and conditioned :❑Does Not supply air limitations, and satisfy hood rating requirements and maximum :❑Not Observable y exhaust rate criteria. ;❑Not Applicable C403.11.1,HVAC ducts and plenums insulated in ;❑Complies ;Exception: Requirement does not apply. i accordance with C403.11.1 and ;❑Does Not C403.11.2'1 constructed in accordance with ❑Not Observable; [ME60]2 C403.11.2,verification may need to occur during Foundation Inspection. ;❑Not Applicable C403.4.3. Closed-circuit cooling tower within ;❑Complies ;Exception: Requirement does not apply. 3.2 1 heat pump loop have either automatic :❑Does Not [ME121]3 ;bypass valve or lower leakage positive; ; closure dampers. Open-circuit tower I❑Not Observable within heat pump loop have automatic!❑Not Applicable ; valve to bypass all heat pump water flow around the tower. Open-or closed-circuit cooling towers used in conjunction with with a separate heat exchanger have heat loss by shutting down the circulation pump on the 1 cooling tower loop. Open-or closed circuit cooling towers have a separate W heat exchanger to isolate the cooling tower from the heat pump loop, and heat loss is controlled by shutting down the circulation pump on the cooling tower loop. C403.4.1. ;Heating for vestibulesand air curtains ;❑Complies :,Exception: Requirement does not apply. 4 I with integral heating include ;❑Does Not [ME63]2 `automatic controls that shut off the (`heating system when outdoor air �❑Not Observable temperatures >45F.Vestibule ;❑Not Applicable ; heating and cooling systems controlled by a thermostat in the ; vestibule with heating setpoint<_ ;60F and cooling setpoint>= 80F. C404.2.1 Gas-fired water-heating equipment ;❑Complies ;Exception: Requirement does not apply. [ME111]z installed in new buildings: where a :❑Does Not singular piece of water-heating equipment>= 1,000 kBtu/h serves ❑Not Observable; the entire building,thermal efficiency :F-]Not Applicable ; >= 90 Et.Where multiple pieces of water-heating equipment serve the building with combined rating >_ 1,000 kBtu/h, the combined input- ; capacity-weighted-average thermal ; efficiency>= 90 Et. Exclude input rating of equipment in individual ¢dwelling units and equipment<= 100 7 kBtu/h. C408.2.2. ;Air outlets and zone terminal devices ,❑Complies ,Requirement will be met. 1 �'have means for air balancing. ;❑Does Not [ME53]3 ;❑Not Observable; ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 13 of 21 Calculation.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions. & Req.ID C403.5, ;Refrigerated display cases,walk-in ;❑Complies :Requirement will be met. d403.5.1, j coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123]3 condensers not located in a ❑Not Observable condensing unit, have fan-powered :❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor; Ssystems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 14 of 21 Calculation.cck Section # Rough-In Electrical Inspection Complies? Corn ments%Assumptions & Req.ID r C405.2.2. ;Spaces required to have light- ;❑Complies ;Exception: Daylight spaces that comply with this code. 2 :reduction controls have a manual ❑Does Not [EL22]1 !control that allows the occupant to ❑Not Observable ;reduce the connected lighting load in , :a reasonably uniform illumination ;❑Not Applicable pattern >= 50 percent. C405.2.1, ;Occupancy sensors installed in I❑Complies ;Exception: Requirement does not apply. C405.2.1. ;classrooms/lecture/training rooms, ❑Does Not 1 :conference/meeting/multipurpose [EL18]1 {rooms, copy/print rooms, E❑Not Observable :lounges/breakrooms, enclosed offices, ;❑Not Applicable :open plan office areas, restrooms, ;storage rooms, locker rooms, ; ;warehouse storage areas, and other :spaces<= 300 sgft that are enclosed ;by floor-to-ceiling height partitions. !Reference section language :C405.2.1.2 for control function in ;warehouses and section C405.2.1.3 ,for open plan office spaces. C405.2.1. :Occupancy sensors control function in ;❑Complies :Exception: Requirement does not apply. 2 :warehouses: In warehouses,the :❑Does Not [EL19]1 :lighting in aisleways and open areas is controlled with occupant sensors that ;❑Not Observable ,automatically reduce lighting power ❑Not Applicable by 50%or more when the areas are unoccupied.The occupant sensors !control lighting in each aisleway independently and do not control !lighting beyond the aisleway being ; :controlled by the sensor. C405.2.1. ;Occupant sensor control function in ;❑Complies ;Exception: Requirement does not apply. 3 open plan office areas: Occupant ;❑Does Not [EL20]1 ;sensor controls in open office spaces ;❑Not Observable >= 300 sq.ft. have controls 1) :❑Not Applicable configured so that general lighting can, PP be controlled separately in control ; ;zones with floor areas <= 600 sq.ft. ; :within the space, 2) automatically turn: : ;off general lighting in all control zones ;within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each ;control zone is reduced by>= 80%of !the full zone general lighting power within 20 minutes of all occupants leaving that control zone,and 4) are ; configured such that any daylight : I ;responsive control will activate space general lighting or control zone ; !general lighting only when occupancy : : :for the same area is detected. C405.2.2, Each area not served by occupancy :❑Complies ;Requirement will be met. C405.2.2, i sensors (per C405.2.1) have time- :❑Does Not 1" switch controls and functions detailed C405.2.2: #in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable; 2 ;❑Not Applicable ; [:EL21]z f J 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 15 of 21 Calculation.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3; Daylight zones provided with ;❑Complies :Exception: Requirement does not apply. C405.2.3. individual controls that control the ❑Does Not 1, lights independent of general area C405.2.3. lighting.See code section C405.2.3 ;❑Not Observable; 2 - Daylight-responsive controls for ;❑Not Applicable [EL23]2 applicable spaces, C405.2.3.1 Daylight: responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 ;Separate lighting control devices for ;❑Complies ;Requirement will be met. [EL26]1 !specific uses installed per approved E❑Does Not ;lighting plans. ❑Not Observable ;❑Not Applicable C405.2.4 ;Additional interior lighting power ;❑Complies ;Requirement will be met. [EL27]1 I allowed for special functions per the ;❑Does Not !approved lighting plans and is automatically controlled and !❑Not Observable separated from general lighting. ;❑Not Applicable C405.2.5 ;Automatic lighting controls for exterior;❑Complies ;Exception: Requirement does not apply. [EL28]no0 !lighting installed. Controls will be ;❑Does Not ;daylight controlled, set based on ;business operation time-of-day, or :❑Not Observable I reduce connected lighting > 30%. ;❑Not Applicable C405.3 :Exit signs do not exceed 5 watts per !❑Complies ;Requirement will be met. [EL6]1 face. ;❑Does Not ;❑Not Observable; ❑Not Applicable C405.6 Low-voricltage dry-type distribution ;, Complies :Exception: Requirement does not apply. [EL26]2 electtransformers meet the ;❑Does Not minimum efficiency requirements of " Table C405.6. ;❑Not Observable; ;❑Not Applicable C405.7 Electric motors meet the minimum ;❑Complies ;Exception: Requirement does not apply. [EL27]2 efficiency requirements of Tables ❑Does Not C405.7(1)through C405.7(4). " Efficiency verified through certification;❑Not Observable under an approved certification ;❑Not Applicable program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification I I programs do not exist). C405.8.2, f Escalators and moving walks comply ;❑Complies ;,Exception: Requirement does not apply. C405.8.2.. jwith ASME A17.1/CSA B44 and have :F-]Does Not 1 rautomatic controls configured to [EL28]2 reduce speed to the minimum i"❑Not Observable permitted speed in accordance with ;❑Not Applicable ; ASME A17.1/CSA B44 or applicable local code when not conveying 1 passengers. I C405.9 Notal voltage drop across the (❑Complies ;Exception: Requirement does not apply. [EL29]2 combination of feeders and branch ;❑Does Not i circuits <= 5%. ❑Not Observable; ;❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2-1 Medium Impact(Tier 2) -3. 1 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 16 of 21 Calculation.cck Section # Insulation Inspection Complies? Comments/Assumptions & R6q.ID C303.1 :Roof insulation installed per ;❑Complies ;Requirement will be met. [IN3]1 manufacturer's instructions. Blown or :❑Does Not poured loose-fill insulation is installed ;only where the roof slope is <=3 in ❑Not Observable ❑ 112. ; Not Applicable ; C402.2.1 I Insulation installed on a suspended ;❑Complies ;Exception: Requirement does not apply. [IN20]1 ceiling having ceiling tiles is not being E❑Does Not specified for roor/ceiling assemblies. ;Continuous insulation board installed ;❑Not Observable :in 2 or more layers with edge joints ;❑Not Applicable ;offset between layers. C303.1 Building envelope insulation is labeled ;❑Complies ;Requirement will be met. [IN10]z jwith R-value or insulation certificate :❑Does Not providing R-value and other relevant ,data. I❑Not Observable; ;❑Not Applicable C303.2 ;Above-grade wall insulation installed ;❑Complies ;Requirement will be met. [IN7]1 :per manufacturer's instructions. :❑Does Not I ;❑Not Observable: ❑Not Applicable C303.2.1 Exterior insulation is protected from ;❑Complies :Exception: Requirement does not apply. [IN14]2 i damage with a protective material. T❑Does Not ;Verification for exposed foundation ; }insulation may need to occur during :❑Not Observable Foundation Inspection. ;❑Not Applicable C105 ;Installed above-grade wall insulation ;❑Complies ;See the Envelope Assemblies table for values. [IN6]1 type and R-value consistent with :❑Does Not insulation specifications reported in ; ;plans and COMcheck reports. ❑Not Observable ;❑Not Applicable C402.2:6 Radiant panels and associated ;❑Complies ;Exception: Requirement does not apply. [IN18]3 j components, designed for heat :❑Does Not transfer from the panel surfaces to the; occupants or indoor space are ❑Not Observable insulated with a minimum of R-3.5. ;❑Not Applicable ; C105 :Installed roof insulation type and R- ;❑Complies ;See the Envelope Assemblies table for values. [IN2]1 (value consistent with insulation ;❑Does Not ;specifications reported in plans and COMcheck reports. For some ceiling ;❑Not Observable Isystems,verification may need to ;❑Not Applicable ; ;occur during Framing Inspection. C402.5.1. ;All sources of air leakage in the ;❑Complies ;Requirement will be met. 1 !building thermal envelope are sealed, UDoes Not [IN1]1 ;caulked, Basketed, weather stripped ; ; ,or wrapped with moisture vapor- I❑Not Observable I :permeable wrapping material to ;❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 " Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 17 of 21 Calculation.cck Section_ " # Final Inspection . Complies? `- Comments/Assumptions & Req.ID C303.3,.• Furnished 0&M instructions for ;❑Complies ;Requirement will be met. C408.2.5'.°systems and equipment to the �❑Does Not [FI17.] _"4: .�reprebuildlng sent five or designated a ;❑Not Observable; ❑Not Applicable C303,.3; f Furnished O&M manuals for HVAC ;❑Complies ;Requirement will be met. C408.2. 5. systems within 90 days of system :❑Does Not 3 _ acceptance. Fl 813' :F-INot Observable; ❑Not Applicable C402.5.6 (Weatherseals installed on all loading ;❑Complies ;Exception: Requirement does not apply. [FI37]1 :dock cargo door openings and provide UDoes Not direct contact along the top and sides I of vehicles parked in the doorway. ❑Not Observable ;❑Not Applicable ; C402.5.6 ;Weatherseals.installed on all loading ;,F-]Complies :Exception: Requirement does not apply. [FI37]1 ;dock cargo door openings and provide ❑Does Not direct contact along the top and sides of vehicles parked in the doorway. :❑Not Observable ❑Not Applicable ; C402.5.6 ;Weatherseals installed on all loading ;❑Complies ;Exception: Requirement does not apply. [F[37]1 ;dock cargo door openings and provide ;❑Does Not direct contact along the top and sides of vehicles parked in the doorway. 1❑Not Observable; ;❑Not Applicable C402.5.6 I Weatherseals installed on all loading ;❑Complies :Exception: Requirement does not apply. [F137]1 dock cargo door openings and provide :❑Does Not ;direct contact along the top and sides ; ; ;of vehicles parked in the doorway. ONot Observable ❑Not Applicable ; C4.02:5.8. Recessed luminaires in thermal ;❑Complies iRequirement will be met. [FI26.]3 a envelope to limit infiltration and be IC �❑Does Not 5 rated and labeled. Seal between interior finish and luminaire housing. ;❑Not Observable i ❑Not Applicable ; 14.03.2.2'�,HVAC systems and equipment ;❑Complies ;Requirement will be met. [FI27]3 capacity does not exceed calculated :F-]Does Not loads. ;❑Not Observable; ❑Not Applicable C403.2.4.` Heating and cooling to each zone is ;❑Complies ;Requirement will be met. 1I controlled by a thermostat control. :❑Does Not [FI47,]3. -Minimum one humidity control device per installed ;❑Not Observable; humidification/dehumidification ;❑Not Applicable system. 6403.2.4. Heat pump controls prevent ❑Complies ;Requirement will be met. 1.1 supplemental electric resistance heat ❑Does Not [FI42]3-•, ,)from coming on when not needed. s ;❑Not Observable; ❑Not Applicable C403:4.1. .;Thermostatic controls have a 5 °F ;❑Complies ;Requirement will be met. 2. = _"jdeadband. ;❑Does Not [Fd3$j3' ;❑Not Observable ❑Not Applicable C403:2.4. Temperature controls have setpoint ;❑Complies ;Exception: Requirement does not apply.' 13 a overlap restrictions. ;❑Does Not [F120]3. _ ;❑Not Observable; :F-]Not Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) ;3;. Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 18 of 21 Calculation.cck section # Final Inspection Complies? -Comments/,Assumptions - & Req ID C403:2.4. Each zone equipped with setback ;❑Complies ;Requirement will be met. 2 controls using automatic time clock or :❑Does Not [FI39]3 programmable control system. ;❑Not Observable; ❑Not Applicable C403:2.4. Automatic Controls: Setback to 55°F ;❑Complies ;Requirement will be met. 2.1", r" (heat) and 85°F (cool); 7-day clock, 2- 1❑Does Not C403.2.4.• hour occupant override, 10-hour ; 2.2 backup �❑Not Observable [F140]3 ;❑Not Applicable I : C404..3 Heat traps installed on supply and ;❑Complies !Exception: Requirement does not apply. [FI1J]3 discharge piping of non-circulating 1❑Does Not systems. ;❑Not Observable; ❑Not Applicable C404.4 jAll piping insulated in accordance with ;❑Complies ;Requirement will be met. [F12, section details and Table C403.11.3. :❑Does Not ❑Not Observable: ❑Not Applicable C404.6.1 , Controls are installed that limit the ;❑Complies :Exception: Requirement does not apply. [FI12]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a ;❑Not Observable ;storage tank. System return pipe is a ; i dedicated return pipe or a cold water ;❑Not Applicable supply pipe. C405.4.1 ;Interior installed lamp and fixture ;;F-]Complies ;See the Interior Lighting fixture schedule for values. [FI18]1 :lighting power is consistent with what !❑Does Not is shown on the approved lighting ; plans, demonstrating proposed watts ;❑Not Observable :are less than or equal to allowed ;❑Not Applicable watts. C405.5.1 ;Exterior lighting power is consistent ;❑Complies ;See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved :❑Does Not lighting plans, demonstrating proposed watts are less than or equal ;❑Not Observable to allowed watts. ;❑Not Applicable ; C408.1.1 ;Building operations and maintenance ;❑Complies ;Requirement will be met. [F157]1 documents will be provided to the j❑Does Not owner. Documents will cover ;manufacturers' information, ❑Not Observable specifications, programming ❑Not Applicable procedures and means of illustrating ; ito owner how building, equipment and systems are intended to be installed, ;maintained,and operated. C408.2.1 ;Commissioning plan developed by ;❑Complies ;Requirement will be met. [FI28]1 registered design professional or :❑Does Not Japproved agency. ;❑Not Observable; ❑Not Applicable C408.2.3. ;HVAC equipment has been tested to ;❑Complies ;Requirement will be met. 1 :ensure proper operation. ;❑Does Not [FI31]1 ;❑Not Observable; j ;❑Not Applicable C408.2.3. ;HVAC control systems have been ;❑Complies ;Requirement will be met. 2 :tested to ensure proper operation, ❑Does Not [FI10]1 !calibration and adjustment of controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 19 of 21 Calculation.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.4 'Preliminary commissioning report ;❑Complies ;Requirement will be met. [F[29]1 completed and certified by registered ;❑Does Not design professional or approved ;agency. :[:]Not Observable ;❑Not Applicable ; C408.2.5: 1Furnished HVAC as-built drawings ;❑Complies ;Requirement will be met. 1submitted within 90 days of system ❑Does Not [FI7]3acceptance. ;❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ;❑Complies :Requirement will be met. 1 - electric power systems within 90 days :❑Does Not [FI16]3 of system acceptance. ❑Not Observable ❑Not Applicable C408.2.5. IAn air and/or hydronic system ;❑Complies ;Requirement will be met. 3 !balancing report is provided for HVAC ;❑Does Not [FI43]1 ;systems. UNot Observable', ❑Not Applicable C408.2.5. :Final commissioning report due to ;❑Complies ;Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 ;receipt of certificate of occupancy. ; ; ,❑Not Observable: ❑Not Applicable C408.3 ;Lighting systems have been tested to ;❑Complies ;Requirement will be met. [FI33]1 !ensure proper calibration, adjustment, :❑Does Not :programming, and operation. ,❑Not Observable, ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) _3_ Low Impact(Tier 3) Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 20 of 21 Calculation.cck Project Title: Elbow East Report date: 05/05/22 Data filename: C:\Users\ural5\Desktop\Projects 2020\Elbow East\Building Department\Elbow East Energy Page 21 of 21 Calculation.cck i 12'-0" HOOD coo o HOOD SEALS (TYP.) _ VENT PLUG 16"X16" DUCT 16"X16" DUCT W z o F bDPADF 40PADFw Ld _ CONTROL �4_ a HEAO 1-y a w rn o 'F f�!:Fy6�F— — —®— — — < � � ADP ADP _ o z w eo n 3 - - - cc T OfJTO Df I z � BADGER A 'PORN GRN F F � ° W I (RANGE GUARD L — — 16 FLOWPOINTS � c.� 0. z I FPS BRANCH 1: 10 'FP I BRANCH 2: .6 FP °- - L7 LPR LPR RPSM 111 (1) 1.6 GALLON (6 LITER) CLASS K FIRE < PULL I 2" GAS o 0 0 0 0 o ADP � , � a ` STATION CHAR BROILER, FRYER FRYER EXTINGUISHER MUST BE INSTALLED WITHIN 30 VALVE 6 BURNER RANGE N/ RADIANT, LL N Z 0 24' GRIDDLE N/ o � FEET OF EACH SET OF (3) INSTALLED FRYERS. 1 CHEESE MELTER BENEATH 36"N 15"N 15"N N o w a HIGH MOUNT 24"D 24"D Tx z co C l Ji. 3 5' 3' -I- I'-3" -F I'-3" 3 C� 1 SECTION ALONG COOKLINE �. � ccW F-101 3/8"=1' — . COOKING SURFACE, NOZZLE 77550 APPLIANCE QTY. NOZZLE NOZZLE LOCATION FAIMING POINT NOTE AES MANUFACTURER:URER: MAX HEIGHT _ _ FESS10`�P PERIMETER < 50" ! AD-4, DIAGONAL IS MEASURED BADGER RANGE GUARD: RG-2.5G RG-4GM 2L RG-6G DUCT, SMALL 0 ADP 0"-6" -CENTER CENTER DIAGONAL < 11.78" I _ FROM NOZZLE TO CORNER Piping Material BLACK SCH 40 Max. Rise 12' Z DUCT, LARGE 2 PERIMETER < 100" ADPL AD-5, DIAGONAL IS MEASURED - m a-, woo 0"-6" CENTER CENTER Supply Pipe Size 3 4" Branch Pipe Size -EEL w DIAGONAL < 11.78" FROM NOZZLE TO CORNER moo �� Zg ��oo 10' LATERAL, Gas Volve Type: MECH Size 2" Manufacturer BADGER o�ao Naa Jw �ZZj PLENUM 2 ADP 1/3 REAR OF & /4 DOWN LONGITUDINALLY ALONG AD-2 ---- 4' TRANSVERSE FROM FORWARD BAFFLE LIP PLENUM Detector Temperature Rating: 360° & 450° Twos �<�oG o�=� 4 BURNER RANGE, ¢D=� R.wA o�Jo HIGH PROXIMITY ' 0 28"X28" i R Hood Size: 12'-0' Duct Size: 2 16'x16' I 20"-42' CENTER CENTER AD-10 L) SoDL 4 BURNER RANGE, 1 BELOW SHELF OR BROILER, ADDENDUM No. 4, BURNER C.L. RG-2.SG, PN 60-120002-001 oz, amwZo YON 2 24"X24" LPR 16'-17' CENTER APPURTENANT COMPONENTS N.O.S. LOW PROXIMITY CENTERED SPACING 12"-14' MAX. FLOW POINTS = 8 UCH 60-120099-002 'ao<�3 rNmw8 ammz - - ---- MAX PIPE VOLUME = 139 CU. IN. zoww5 aDz;i o�wo GRIDDLE � 1 42"X30" ADP 13'-48" PERIMETER CENTER s „ A+ CONTROL BOX 60-120010-001 MAX % PIPE VOLUME = 95 CU. IN. MECH GAS VALVES FRYER W/ DRIP2 18"X18" F 27"-45" ABOVE COOKING SURFACE CENTER MAY.HAVE A 5" DRIPBOARD RG-4GM, PN 60-120006-001 1„ 60-120072-001 BOARD, HIGH MOUNT _ _ MAX. FLOW POINTS = 12 1Y4 60-120073-001 SPLIT VAT FRYER i 0 14W"X15D" F I 27"-45" ABOVE COOKING SURFACE CENTER MAY HAVE A 6" DRIPBOARD MAX PIPE VOLUME = 400 CU. IN. 1Y" 60-120074-001 ' MAX %" PIPE VOLUME = 95 CU. IN. 2" 60-120075-001 FRYER DRIPBOARD I< RG-6G H 1" 0 24"X24" F 27.5"-46" PERIMETER CENTER MAY HAVE A 1" DRIPBOARD 360° FUSIBLE LINK 87-120095-360 >- , PN 60-120005-001 r +-� z 450' FUSIBLE LINK 87-120095-450 z CHAIN BROILER, OPENS I MAX. FLOW POINTS 18 U d VERTICALLY DOWN TUNNEL & OPPOSITE REAR CORNER OF = � o 0 28"X29" 2X ADP 12"-48" ---- MAX PIPE VOLUME 400 CU. IN. _j j TOP CENTERED ABOVE TUNNEL & CENTER = CO o w CHAR BROILER, GAS MAX %" PIPE VOLUME = 95 CU. IN. L1J U) 0 o 2 24"X21" ADP 24"-48" ABOVE COOKING SURFACE CENTER NOZZLE MUST BE ANGLED BETWEEN — CO r co RADIANT 45°-90° FRON HORIZONTAL x Fryers to have High Limit Control to shutloff fuel at 425°. Q o a u; lo CHEESEMETLTER, TOP 4" OF CENTER OF GREASE DRAIN x Detectors shall be located over ever piece of equipment. __I Z c6 1 30.25"X34" ADP AT ENTRY PERIMETER ---- y p J UJ > ;-' W a SALAMANDER OPENING OFF OPENING x The System installed as per monufacturers specs and the AHJ. Q J o w a WOK 0 28"aX8"D GRW 35"-56" CENTER CENTER MINIMUM WOK SIZE IS 14"0, 3" x The System has been installed as per UL?00. F- F- W 'L3 Y DEEP x The following functions to operate upon system discharge: z u 0 * Supply air damper closes * Gas fuel shuts off in kitchen _ MINIMUM PIPE LENGTHS BEFORE LIQUID HAZARD OR LPR NOZZLE CABLING RESTRICTIONS (ALL CABLING IN %" EMT U.N.0) - A+ HEAD * Exhaust fan remains on * Electric shut off under hood —I O Cn w PIPE SIZE DESCRIPTION LENGTH PULLEYS "T"'S NOTE * All systems to activate simultaneously in some hazard area. c L) 8% LF + (1) 90° ELBOW PULL STATION 100' 30 1 "T"=2 PULLEYS * Fire Alarm shall activate. Y Y" 7 LF + (2) 90' ELBOWS GAS VALVE 100' 30 1 "T"=2 PULLEYS x Manual Pull is located between 10 and 20 ft. from hood and 4 ft. o %4" & 1" 10 EQUIVALENT FEET OF Yz" PIPE FUSIBLE LINKS 100' 30 0 ---- from floor. LPR NOZZLE: 9 LF & 12 EQ. FT TO NOZZLE, MIN TOTAL: 11.08 FTTURING N/A N/Ax All fuel sources are GAS unless otherwise;noted. Io�/l APP VED AS NO/TED ? S50036 '00"E 113.52 DATE: aB.P.# ` 7�J� _ — — — — FEE: BY: RETAIN STORM WATER RUNOFF NOTIFY BUILDING DEPARTMENT AT PURSUANT TO CHAPTER 236 765-1802 6 AM TO 4 PM FOR THE OF THE TOWN CODE, FOLLOWING INSPECTIONS: E �J � BEFQ} � p� 1. FOUNDATION - TWO REQUIRED �� ���� FOR POURED CONCRETE cl2 2. ROUGH - FRAMING & PLUMBING PLUMBER CERTIFICATION 0 3. INSULATION ON LEAD CONTENT BEFORE 4. FINAL - CONSTRUCTION MUST CER TIFICA TE OF OCCUPA NC Y BE COMPLETE FOR C.O. All exterior lighting ALL CONSTRUCTION SHALL MEET THE SOLDER USED IN WATER Installed,replaced or 00 REQUIREMENTS OF THE CODES OF NEW SUPPLY SYSTEM CAAjVCrepaired shall conform Q YORK STATE, NOT RESPONSIBLE FOR EXCEED 2/10 OF 1% LEAD. to Chapter 172 DESIGN OR CONSTRUCTION ERRORS. co co of the Town Code >;.0L'0'MBiNG `Aq L PLUMBING WASTE COMPLY WITH ALL CODES OF "&WATER LINES r:rE7 NEW YORK STATE & TOWN CODES TIIaG BEFORE C01lERWG,» A-S REQUIPED AND CONDITIONS OF ELECTRICAL ` INSPECTION REQUIRED BOARD S , USTEES AI VAI. - EXISTING I OCCUPANCY OR C011APLY WITH CHAPTER ~46~ D PARKING USE IS UNLAWFUL FLOOD DAMAGE PREVENTION JIM,, r1 I '1[Q' AREA WITHOUT CERTIFICATESOUTPOIBUIL.DWL TOWN OF SCATMOLD OF OCCUPANCY JO MAPI o� o O� North Sea r% 0 rive 0 � w ���.� z v S o � �- w � -- EXISTINO SHED �P- lXIS�TINCa 6'� --------------,I TO 5E REMOVE cc a EX ST I N(5 FEN(�- E 5ARR I ER TO REI'vIA I N I STOCKADE FENCE 1 .a EXISTING 1 � EXISTING GRASS AREA ; SHED I I ------ I 12'x24' ---------- EX I STI NO FREFAE3 CON CRETED14 12PEO"A FREEZER TO 5 _ EFLA� � I N SCTM # 1000-54.-5-22 existing w 1 1 I PROPERTY: 50 North Sea Drive 0 I EXISTINGI ( � ADDRESS Southold, NY 11971 Q I v (FREEZER( AND VOLUMEI� r,,, el/'� o a ---- i"'" G'��`-� 50 N Sea Drive LLC O I VI-� 1,,kbWNER: I K ; w �,_o�� rnOL Ce �� 28 South Delrey Rd } 1 EX I ST NO SHED / C z o proposed S S Montauk, NY 11954 1� FREEZER TO f5E o RMO� SITE: 29,932 sf = 0.59 ac EXISTNO RESTAURANT TO R 1�A IV I ZONING: R-40 I NOTE : ALTERATION LEVEL AS i�E=-R NYs z SURVEYOR: Michael K. W' EXISTN6 5U LD I N� CODE : LEVEL 2 Wicks W UA Q� wo I'n-�r ,W Land Surveying o 15 Frowein Road NOTE : �j n l Sh � S Sh a k (-Dmf Center Moriches, New York 11934 LICENSE # 050390 THE FRO,�EGT WILL NOT 5E A � � w S �� �d �� � 1 / 12 / 2 22 �j lU� � DATED 0 SU5TANT I I MRO 22.0' MINTS 21.6' � �-- SER FEMA REOU REMENTS ANS existing EXI5TINCG WOOD DL OW- 1 ECK existing THE �ROJE�T LL NOT MEET THE EXISTING � A 3 T SIGN N N EXISTING o DEFINITION OF DEMOLITION AS � Q) EXISTING FENCE � PARKING � SOUTHOLD, NEW YORK FER TOWN �0�E BARRIER TO REMAIN N AREA d' DATE: 3 / 22 / 2022 N40REVISED DATE: 5 15 / 2022 °53 '0011W CO REVISED DATE: 5 / 17 / 2022 URAL TALGAT ARCHITECT 436 7th STREET SCALE: 1 "=1 o'-o" Kenneys Road GREENPORT, NEW YORK 11944 (631)477-8963 Building Permit ELECTRICAL LEGEND ME EMERGENCY LIGHTING EXIT EXIT 515N W/ EMERGENCY LIGHTING 5/D 5MOKE DETECTOR EXISTING 4x4 P05T c/o SMOKE / CARBON MONOXIDE DETECTOR BARRIER T'rPICALI A�NSUL AaNSUL EIRE 5YSTEM EXISTING WOOD DECK ON EXISTING DECK STRUCTURE EXISTING WALL EXISTING FENCE TO REMAIN T'l BARRIER TO REMAIN EXISTING EXISTING EXISTING ENTRY FOYER COVERED q)0 NEW WV GONG FTG TYP NEW R-la /TILE FLOORING ON NEW 2x6 WALL VEXISTING WOOD XIT EXISTING CONCRETE SLAB DECK DOOR EXISTING WALL/CEILING BATT INSULATION ROOF r�� P NIC FINISHES TO REMAIN ON C EXISTING WALL ABOVE DW EXISTING WALL STRUCTURE NEW ST 4x4xl/4 �45 TO REMAIN TYP 5 L COLUMN ON �L �� EXISTING BATHROOMS WITH NEW EXf5TIN6 GONG FTG TYP 7 �b" •(� FLOOR, WALL 8 CEILING �— 5/D CW24 ` CW24 �, 1}� FINISHES, EXISTING BATHROOM U=0.28 �/ U=0.28 6I� O,� FIXTURES TO REMAIN SHGC=0.32 SHGC=0.32 XT — EXISTING NEW (3 2xIO i NEW (5) 2x1O N W (3) 2xl FREEZER EXISTING WALL i EXISTING FLOORING TO REMAIN TYP N ABC FIRE EXISTING WALL ON EXISTING EXTINGUISHER TO BE REMOVED NEW � rj X CONCRETE SLAB EXISTING UP iIi EXISTING BATHROOM TOILE OILET EXISTING WALL/CEILING POST ( ADA RAMP: EXISTING i DOOR TO BE RELOCATED FINISHES TO REMAIN ON i NEW TILE NEW TILE EXISTING WALL TYPICAL WOOD "OAK" WALL TO ED i EXISTING 5x8 ROOF FLOORING ON FLOORING ON 2.5" height ram REMOVED i i STRUCTURE 9 P RAFTERS ® 16 OG EXISTING EXISTING 1:12 max slope ANDRAILS NEW R-32 SPRAY FOAM CONCRETE CONCRETE C34 IGC,/ANSI 405.2 BOTH SIDES CLOSED CELL CEILING SLAB5 D 5 D SLAB EXISTING BATHROOM WITH NEW U=0.28 IGC/AN51 405.8 OF RAMP INSULATION BETWEEN 0 SHGC=0.32 ICG/ANSI 505 � ) EXISTING RR ABOVE W/ 5/5" ____= 0i f EXISTING WALL FLOOR, WALL 4 CEILING � TO REMAIN TYP (FINISHES, EXISTING BATHROOM - TYPE "X" GYP FINISH FIXTURES TO REMAINIn oc 0 EXISTING DROP �- ei,. o cq I-6 NO EXISTING w M CEILING c/w REMOVE �`�eq DININ(5/BAER AREA NEW BA I D NEW TILE FLOORING LOGATI N i i A TOT 14 SEA x 9EXISTING BAR TO •'o EXISTING ABC FIRE­� ON EXISTING cV BE REMOVED AND CONCRETE SLAB ADA BAR REBUILT IN MECHANICAL I LE.T EXTINGUISHER Li4FJGHZ8-4--- - c _ LOCATION 5HOWN ROOM FS751 S/D I l bb" WIDE } EXISTING FLOORING ON EXISTING EXISTING EXISTING WALL I I X CONCRETE SLAB 5TORA�GE TO REMAIN TYP EXISTIN - - - --- ------ ---- —A)L -- -------------------� ROOM i r- ------- - - EXISTING WALL/CEILING CW24 O�ivUQ�tN�iY: ,42 LOVE EXISTING WALL FINISHES TO EE FINISHES TO REMAIN ON EXISTING FLOORING e SHGC=0.32 TOTAL TO YVALL REMAIN STRUGTUI TING z ABC FI EXISTING WALL STRUCTURE s�q ,,` (� •� ON EXISTING C r ~ EXTINGUISHER r'/0 EXISTING CONCRETE SLAB o 1,260 scL. ft. ne � --------------- - EXISTING WALL/CEILING �w 54 occupantl W PO T 4X4x1/ - G FIRE OFFICE L GOLU EXISTING WALL w i FINISHES TO REMAIN ON Assembly ON 2 " SQ x 12" i TO REMAIN TYP oo� EXTINGUISHER EXISTING WALL STRUCTURE EXISTING y EEPNG FTG , +� WOOD DECK unconcentrote #4 EACH ON EXISTING DECK (tad!es and chairs): NAY,E50 OM, P _ STRUCTURE I 15 sf / occupant, ne't ABG FI EXISTING NEW WA EXTINGUISHER T01 REMAIN TYP L \\ iGITGHEN EXISTING 2x8 ROO� 5/D EXISTING TILE FLOORING ON EXISTING CONCRETE SLAB AFTERS a I6" OG C� G W EXI5TIN RC NEW R-32 SPRAY i'XISTINALL/CEILING FIN,J5HE5 TO C34 FOAM CLOSED CELL SETUP AREA �? �517 . U=0.28 CEILING INSULATION NEW TILE FLOORING ON EXISTING PLUMS IXTURES TO REMAIN G/o -AFI 13 SHGC=0.32 BETWEEN EXISTING EXISTING CONCRETE SLAB EXTINGUISHER RR ABOVE W/ 5/6" NEW E TILED WALL5 ON XISTING TYPE I HOOD EXISTING TYPE "X" GYP FINISH EXISTING WALL STRUCTURE EXISTING REMOVE EXISTING 4x4 POST EXISTING CEILING FINISHES BARRIER DROP CEILING UP TO REMAIN ON EXISTING EXi TYPICAL I EXISTING WALL STRUCTURE �- DO R 0 EXISTING EXISTING WALL o PAN G COVERED TO REMAIN TYP NSUL TO REMAIN TYPUo HD b+ WOOD `yw DECK o+ �o ROOF ABOVEEXISTING WOOD 7e EXISTING DECK EX 1 STING DECK ON EXISTING FENCE I EXISTING EXISTING WALL BARRIER TO REMAIN EXISTING NEW CASED LI- o TO REMAIN TYP EXI :3, 5TRUcTURE RAILING TO BE POST (2)2x4 DINING AREA o o 41 DO R 6+� FREEZER REPLACED SEE 1 NEW TILE FLOORING ON EXISTING w PAN G o EXISTING FLOORING ON DETAIL 2 WOOD STRUCTURE FLOOR - HD EXISTING CONCRETE SLAB UCO 28 5/D REMAIN OEXISTING ES NALL FINISHES TO EX15TING WALL O g/D DN TO I REMAISTING NONEXISTLL ING NEW 2x6 WOOD SHGC=0.32 STRUCTURE Fz--v ABG FI� EXISTING LL STRUCTURE LING F URE TO TOP RAIL NEW R-32 SPRAY FOAM CLOSED N u EXTINGUISHER REMAIN ON EXISTING STRUCTURE CELL CEILING INSULATION BETWEEN X NEW 2x4 EXISTING RR ABOVE W/ 5/8" TYPE w • WOOD "X" GYP FINISH INTERMEDIATE REMOVE EXISTING DROP CEILING EXISTING WALL • VERTICAL I TO REMAIN TYP SUPPORT 45" OG EXISTING WALL CW24 CW24 CW24 CW24 CW24 CW24 TO REMAIN TYP • U=0.28 U=0.28 U=0.28 U=0.28 U=0.28 U=0.28 NEW SHGC=0.32 SHGC=0.32 SHGC=0.32 SHGC=0.32 SHGC=0.32 SHGC=0.32 .-� HORIZONTAL I Y GABLES, EXISTING WOOD NOTE: ALL EX I ST I NG lel I NDOJntS TO BE REPLACED IN�l l�I ND EXISTING WOOD • 3/16 DIA DECK ON EXISTING DECK ON EXISTING AT 4 OG DECK STRUCTURE DECK STRUCTURE EXISTING EXISTING FENCE EXI5TING • 4x4 POST BARRIER TO REMAIN 4x4 POST BARRIER BARRIER TYPICAL TYPICAL UPPER DIAL ROOM PLAN- SCALE: 1/4" = V-0" N - NOTE: N ALTERATION LEVEL AS PER NYS SOUTHOLD, NEW YORK EXI STI NCS BUILDING CODE: LEVEL 2 DATE: 4 / 1 / 2022 NOTE: REVISED DATE: 515 / 2022 LOWER THE PROJECT Jul ILL NOT BE A REVISED DATE: 6 / 6 / 2022 DININ6R00M SUBSTANT I AL IMPROVEMENT AS PER LEVEL URAL TALGAT FEMA REGU I REMENTS AND THE ffs R"Al Ll IN E WIN%I L PROJECT YNILL NOT MEET THE ARCHITECT DEFINITION OF DEMOLITION AS PER 436 7th STREET SCALE.. 1/4., _ - TONN GODS GREENPORT, NEW YORK 11944 (631)477-8963 Building Permit i I-- 3" VENT THRU ROOF — � 2VENT EXTERIOR HANP HANP NALL 51N< I ICE BIN RAGK I IGE BIN I NK 3" FRESH AIR VENT FIRST FLOOR 4" C.1. 3" WASTE 4"X3" G.I. HOUSE TRAP P LlJi�ii1":51` 1 No G RISER DIAGI��lii BAS NTS � 3" VENT THRU ROOF 2" VENT EXTERIORI EXIST TOILET I EX15T TOILET I EXIST TOILET I I EXIST WALL I I I I MECHANICAL �G I LAV LAV wG LAV NC I ROOM 3" FRESH � I I I 03I 03 I PLUMBsING �IVE � AIR VENT I I MOP DIAGKAM FIRSTFLOOR I SINK 4" G.I. I I D ELBOW 3" WASTE 4"X3" G.I. HOUSE SOUTHOLD, NEW YORK TRAP DATE S / 5 / 2022 REVISED DATE: 6 / 6 / 2022 p� �± q ,�+ AC �tGTT URAL TALGAT � LUMBIItl �7 �OSE1 � I/�VR/�M GXISTIItlOILES ARCHITECT NTS 436 7th STREET GREEN PORT, NEW YORK 71944 (631)477-8963 Building Permit STRUCTURAL REVIEW BY STEVE MARESGA, PE WIND-BORNE DEBRIS PROTECTION FOR OPENINGS 88-07 WEST MONTAUK H I GHWA`I', HAMFTON BAYS, NY I I cf 4& H" OT rQQ%�a fi'HONf= 651 728 X480 FOR WALL 0f=f=N I NCS PROTE=CTION OF 150 MPH 5-SE=C0ND WIND GUSTS ( MAXIMUM MEAN Roof= Hf=I CHT: ��') SIMPSON LSTA - 20 GAGE USE/OCCUPANCY CLASSIFICATION DESIGN CRITERIA: RIDGE STRAP ALL ROOF RAFTERS PRI MARY OCCUPANCY: ASSf=MBLY ° ( A-2 Assembly use, Restaurant) DESIGN IN ACCORDANCE WITH ,. 2020 BUILDING CODE OF NEW YORK STATE I ICE SHIELD UNDERLAYMENT AND 5ECTION 2505 - CONVENTION LIGHT FRAME� SHUTTER, ASSEMBLY REOU I RED - 24" FROM EDGE HEIGHT CONSTRUCTION N.T.5. ° •' \ ° - PREFABRICATED TRUSSES I I I FOR PANEL SPANS: O < 4'O WIDE SPAN 1 \ ® 24' OG OR 2XI2 R.R. ® 16110C 55 -0 MAXIMUM GROUND SNOW LOAD - 45 P5F. 23/32" APA SPAN-RATED 48/24 SHEATHING GRADE PLYOOD I WIND SPEED - 150 MPH W \ (OVERLAP AROUND OPENINGS 4") K ALTERNATE POSITION OF RIS FIRE AREA CATEGORY I i I ° HURRICANE CLIP USE ASSEMBLY: 1 I SIMPSON H3 ATTACHING STRUCTURAL PANEL: FASTEN TO BUILDING w/ °I I A-2 ASSEMBLY SEISMIC DESIGN CATEGORY - B #10x3" (w/ WASHERS) GALVINIZED OR STAINLESS STEEL BUILDING AREA: 2,500 5F WEATHERING - SEVERE WOOD 50REW 0 16' O.G. I I o SIMPSON H2 HURRICANE ALTERNATIVE FASTENER FOR SHUTTER TO BUILDING: IP NAILED. FROMFTER TO I FROST LINE DEPTH - 56" #10 TEE NUTS ATTACHED TO BLDG. wW/ W / #IOxl-1/2 ( ASHERS) I I TTYY KCAL ALL RAFTERS TERMITE - MODERATE TO HEAVY MACHINE BOLT ® 12" O.G. a -' I 5 - 8d NAILS EACH END DECAY - SLIGHT COORDINATE ry ARCHITECT TYPE OF CONSTRUCTION CLIPS FOR TRUSSES IGE SHIELD UNDERLAYMENT REQUIRED - YES \ � I - I APA RATED PLYWOOD TO Type EJB construction ° o EXTEND TO TOP OF TOP PROVIDE Sd COMMON NAILS ® 4" O.G. AT \ I PLATE. EXTERIOR EDGE OF ALL SHEATHING. GENERAL NOTES I. ALL WORK MATERIAL, AND EQUIPMENT SHALL BE IN 13. SEWAGE DISPOSAL SYSTEM AND FRESH WATER SUPPLY ACCORDANCE WITH THE 2020 NEW YORK STATE SHALL BE DESIGNED AND BUILT IN ACCORDANCE BUILDING CODE AND LOCAL AUTHORITIES. WITH THE SUFFOLK COUNTY DEPARTMENT OF HEALTH. ULTIPLE SECTION ASSEMBLY: 14. THIS STRUCTURE HAS BEEN DESIGNED IN 1/4" THICK BOLTS 0 ZOO 2. ALL CONCRETE SHALL BE STONE AGGREGATE WITH A ACCORDANCE WITH THE 2018 INTERNATIONAL ENERGY I 1 I MINIMUM 28 DAY STRENGTH OF 3500 PSI CONSERVATION CODE. 1 1 I I 1 3. ALL LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR- 15. ENGINEER TO BE NOTIFIED IN WRITING OF ALL LARCH STRUCTURAL GRADE #2 OR BETTER. CHANGES PRIOR TO AND DURING CONSTRUCTION. 1 I I I I I 4. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL I6. ELECTRICAL AND MECHANICAL COMPONENTS TO BE I i I 1 I I STAIR AND FLOOR OPENINGS, POSTS AND PARALLEL DESIGNED AND SPECIFIED BY OTHERS. PARTITIONS, EXCEPT AS NOTED ON DRAWING. 17. ALL STRUCTURAL STEEL TO BE ASTM A36 WITH ONE 5. BRIDGING TO BE PROVIDED FOR ALL JOISTS AND GOAT EPDXY PAINT. ALL FASTENERS TO BE ASTM rO PLYWOOD SHEATHING I I I 1 I 1 i I I I OVER LAP Box FLOOR BEAMS. SPACING NOT TO EXCEED 8.0 FT. A-325 BOLTS, 3/4" DIAMETER. 1 BEAM - TOP + BOTTOM. 18. CONTRACTOR SHALL OBTAIN ALL PERMITS AND I 1 I I 6. ALL DIMENSIONS AND GRADE CONDITIONS TO BE VERIFIED BY CONTRACTOR(5) PRIOR TO START OF INSURANCE NECESSARY TO PROTECT THE ENGINEER AND OWNER. I I I I I I I I DOUBLE TOP CONSTRUCTION AND ORDERING OF MATERIALS. THIS SHUTTER ASSEMBLY , � I , I I STUDS®16" O.G. PLATE FOUNDATION HAS BEEN DESIGNED FOR A 501L DO NOT BACKFILL AGAINST FOUNDATION WALLS BEARING CAPACITY OF TWO (2) T5F AND GRADES UNTIL FLOOR SYSTEM INSTALLATION IS COMPLETE. I I I I I LESS THAN 5%. CONTRACTOR SHALL VERIFY THAT FOR PANEL SPANS:4' OR WIDER SPAN I°'" I°' THESE CONDITIONS ARE MET. ALL FILL BENEATH 20. PROVIDE CARBON MONOXIDE ALARMS ON EACH LEVEL 1 I I I CONCRETE SLABS TO BE COMPACTED TO 95% AND IN BASEMENT ( IF APPLICABLE ), POSITION NEAR 1/2" APA SPAN-RATED 48/24 SHEATHING GRADE PLYWOOD RELATIVE DENSITY. ENTRY FROM HOUSE TO ATTACHED GARAGE AREA. (OVERLAP AROUND OPENINGS 411) I I I I WRAP + NAIL STRAP K:5 @ 24 OG AROUND SILL PLATE 21. SMOKE DETECTORS AS REQUIRED BY THE 2x4 STRONG-BAC �� I�' �' 4 - 8d NAILS �. ALL HEADERS 6.0 FT IN LENGTH AND OVER TO BE A55EMBLY: I I I I AT ANCHOR BOLT SUPPORTED BY DOUBLE UPRIGHTS, a.0 FT AND OVER 2020 BUILDING CODE OF NEW YORK STATE 5I4P50N M5T2"1 1 I I(l" WIDE - 20 GAGE BY TRIPLE UPRIGHTS. ALL HEADERS TO BE 22. ANY ALTERATION, REPAIR, ADDITION OR CONVERSION 1). PREASSEMBLE PLYWOOD TO 2x4'5: # 10x3" (w/ WASHERS) GALVINIZED OR I I METAL STRAP ®48" OC. MINIMUM OF 2-2x8 OR AS SHOWN ON DRAWING. REQUIRING A BUILDING PERMIT SHALL MEET THE 5TAINLE55 STEEL PSOOD SCREW @ 12" O.G. 101 " NAL SHEATHING TO SILL PLATE 8. PROVIDE FIRE5TOPPING AT ALL LEVEL 2020 BUILDING CODE OF NEW YORK STATE 2). ATTACHING 5TR.UCTURAL PANEL: FASTEN TO BUILDING w/ F;a NAILS ® 4" O.C. PENETRATIONS #10x3" (w/ WASHERS) GALVANIZED OR 5TAINLE55 STEEL 23. THE BUILDING GORES ALSO APPLY TO ACCESSORY WOOD SCREW ® 1611 O.G. '?; s'r-`` a. PROVIDE FLASHING AT ALL ROOF BREAKS, ::,;�. STRUCTURE DESIGN. ALTERNATIVE FASTENER FOR SHUTTER TO BUILDING: :2 - #5 REBAR :`�:.:. :;:: �;;6 SILL PLATE CHIMNEYS SKYLIGHTS EXTERIOR DOORS WINDOWS #10 TEE NUTS ATTACHED TO BLDG. w/ #10x1-I/2 ( W/ WASHERS) A�Q TREATED. AND DECKS ETC.. 24. OVERHEAD DOORS TO BE RATED FOR 130 MPH. WIND LOAD MACHINE BOLT (9 12" O.G. SEE FOUNDATION DWG. 10. DO NOT SCALE DRAWINGS. FOR DESIGN. "';V ' 5/8" x 12" A.B. ®48" OG. w/FENDER WA5HER. ''+ ;;d.i; I I. ARCHITECT NOR ENGINEER 15 NOT RESPONSIBLE GLAZE® OPENING FOR THE INSPECTION OR SUPERVISION OF THIS CONSTRUCTION PROJECT. FEDERAL, STATE PROTECTION IS REQUIRED FOR ALL GLAZED AREAS. RDANCE !^11TH LARGE MISSILE TEST OF AND LOCAL ZONING AND BUILDING GORE COMPLIANCE IN ACCO ASTM E fgb AND OF ASTM E M1 SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR MAY USE WOOD STRUCTURAL PANELS 1N LIEU of THE ABOVE MENTIONED WINDOWS. HOLD DOWN + SHEAR CONNECTION PANELS TO BE PRECUT TO FIT OVER WINDOWS WITH HARDWARE PROVIDED. FA5TENER5 TO BE DESIGNED TO CRITICAL LOAD PATH ALIGN WITH WINDOW JACK POSTS , HEADER + SILL PLATE. SHALL COMPLY W/ 2020 BUILDING GORE OF NEW YDRK STATE PANELS TO BE MAINTAINED ON SITE. FRAMING NOTES LABEL LOCATIONS ON EACH PANEL. SECTION 2308 - CONVENTIONAL LIGHT FRAME CONSTRUCTION I. ALL FRAMING LUMBER SHALL BE GRADE STAMPED 10. PLYWOOD SHEATHING TO BE NAILED WITH 8 d ® 4" DOUGLAS FIR-LARCH STRUCTURAL GRADE No. 2 OR ox.. EXTERIOR EDGE5 AND 6 d ® 12" o.c. r BETTER. I NTERMED I ATE. 2. ALL 5HEATHING TO BE APA RATED, EXPOSURE I, 5/8" 11. ALL INTERIOR AND EXTERIOR FINISHES, FLASHING a NAILING SCHEDULE MIN. THICKNESS OR AS NOTED. AND WATERPROOFING SHALL BE BY CONTRACTOR. v� �� 3. ALL 5UBFLOORING TO BE APA RATED STURD-I-FLOOR, SHALL COMPLY W/ 2020 BUILDING GORE OF NEW I Z" STATE EXPOSURE I, 3/4" MIN. THICKNESS. ALL EDGES OF 12. ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE TABLE 2304.10.1 - FASTENING SCHEDULE PLYWOOD TO BE SET ON SOLID BLOCKING. GLUE AND AND STUD WITH GALVANIZED HURRICANE TYPE SIZED FOR COMMON NAILS; CONTACT ARCHITECT FOR BOX NAIL SIZES NAIL PLYWOOD SUBFLOOR TO FLOOR JOISTS. CONNECTORS BY "TECO" OR APPROVED EQUAL. ° RAFTER/TOP PLATE 3-8d (TOE NAILED) 4. ALL HEADERS 6-0" AND OVER SHALL BE SUPPORTED 13. ALL PRE-ENGINEERED LUMBER SHALL BE GEORGIA h CEILING JOIST/TOP PLATE 3-8d (TOE NAILED) WITH DOUBLE UPRIGHT5, a'-O" AND OVER WITH PACIFIC GPI SERIES WOOD-I-BEAMS AND LVL CEILING JOIST/PARALLEL RAFTER '7-16d (FACE NAILED) TRIPLE UPRIGHT5. ALL HEADERS SHALL BE A PRODUCTS OR EQUAL. ALL JOISTS, GIRDERS AND o `lo ° CEILING JOIST LAPS OVER PARTITION 7-16d (FACE NAILED) MINIMUM OF 2-2X8 OR AS SHOWN ON DRAWING. HEADERS SHALL HAVE BEARING 5TIFFENER5 INSTALLED a COLLAR TIE/RAFTER 3-I0d (ea. end 1-1/4" strip) 5. SOLID BLOCKING SHALL BE PROVIDED FOR ALL JOISTS AS PER MANUFACTURERS RECOMMENDATIONS. WEB BLOCKING/RAFTER 3-8d (TOE NAILED) AND FLOOR BEAMS AS PER IBC 2015 CODE OR AS NOTED STIFFENERS SHALL BE REQUIRED AT ALL LOAD AND G�4BLE ROOFS 4';>`;';»»`i'<: RIM BOARD/RAFTER 2-ibd (END NAILED) ® 8'-O" O.G. MIN. PROVIDE 2" SPACE FOR AIR BEARING POINTS AT A MINIMUM. A SINGLE 1 5/4" TOP PLATE/TOP PLATE 3-16d (FACE NAILED) CIRCULATION IN ROOFS. LVL RIM . J015T SHALL BE REQUIRED AT FLOOR o 4,10 TOP PLATE AT INTERSECTIONS 8-16d (FACED NAILED) (0. DOUBLE FRAMING AROUND ALL OPENINGS ( skylights, PERIMETERS. HANDLING, STORAGE, AND ERECTION OF STUD/STUD 2-16d (PAGE NAILED) .stairs etc. ) OR AS NOTED ON DRAWINGSCOMPONENTS SHALL BE AS PER MANUFACTURERS a ° HEADER/HEADER 16d (FACE NAILED) RECOMMENDATIONS. h TOP or BOTTOM PLATE/STUD 2-16d (END NAILED) '7. DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL BOTTOM PLATE/FLOOR JOIST 2-I od (FACE NAILED) PARTITIONS OR AS NOTED ON DRAWINGS. 14. ALL MULTIPLE LVL PRODUCTS TO HAVE 2 ROWS OF 1/2" DIA. JOIST/SILL, TOP PLATE or GIRDER 4-8d (TOE NAILED) GALVANIZED MACHINE BOLTS 12" O.G.. lo° o X45 ° BRIDGING/JOIST 2-5d (TOE NAILED) 8. ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED BLOCKING/JOIST 2-8d (TOE NAILED) "WITH (RATED GALVANIZED METAL CONNECTORS BY 15. THIS DRAWING IS AN INSTRUMENT PREPARED TO 7BLOCKING/SILL orTOP PLATE 3-16d (TOE NAILED) TECO OR APPROVED EQUAL. FACILITATE CONSTRUCTION AND SHALL NOT BE 0:: h GABLE ROOFS LEDGER STRIP/BEAM 3-16d (FACE NAILED) q. NAILING SCHEDULE SHALL BE AS PER THE CONSTRUED AS A CONTRACT BETWEEN BUILDER AND 0< o X45 O JOIST ON LEDGER/BEAM 3-5d (TOE NAILED) 2020 BUILDING CODE OF NEW YORK STATE OWNER. 10° o 4,30 O to BAND J015T/JOI5T 3-16d (END NAILED) TABLE 2304.10.1 - FASTENING SCHEDULE AS A MINIMUM. BAND JOIST/SILL or TOP PLATE 3-I6d (TOE NAILED) ALL 2X6 STUDS SHALL RECEIVE 5-IOD NAILS AT AT HIGH PRR ESSURE ZONE - 6" OO.G. PROVIDECOMMON NAILS o.C. PLYWOOD ROOF DECKING ad ®4" O.G. EDGES, ®8 O.G. FIELD . HIP ROOFS AT INTERIOR PORTIONS OF ROOF - TYP. STRIP SHEATHING 8d (ONE/RAFTER) SILL AND PLATE. ALL EXTERIOR NAILS SHALL - o o PLYWOOD WALL 5HEATHING ad @4" O.G. EDGES, @8'O.G. FIELD BE GALVANIZED. Io ` ° ('50 PLYWOOD SUBFLOOR DECKING 8d m6" O.G. EDGES, (D17 O.G. FIELD L 0 W PROVIDE Sd NAILS a 4" O.G. AT PERIMETER INTERIOR PORTIONS OF PANELS IN HIGH PRE55URE ZONES. NOTE : a = 4 FT. IN ALL CASES THOLD, NEW YORK COMPONENT AND CLADDING PRESSURE ZONES DATE: 3 / 22 / 2022 URAL TALGAT ARCHITECT 436 7th STREET G EENPORT, NEW YORK 11944 _ DETAILS (631)47v%UCTUR A L INOTES & 7-8963 Building Permit