Loading...
HomeMy WebLinkAbout47857-Z ��o�Og11FFOLKCpGy Town of Southold 10/1/2022 P.O.Box 1179 > 53095 Main Rd y nxi�i o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43461 Date: 10/1/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 4295 Vanston Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 111.-14-38 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/19/2022 pursuant to which Building Permit No. 47857 dated 5/26/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to McCartney,Joseph&Barbara of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47857 '?f/9/202 PLUMBERS CERTIFICATION DATED Aut or e Signature gllffal.t TOWN OF SOUTHOLD ay BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE "oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47857 Date: 5/26/2022 Permission is hereby granted to: McCartney, Joseph 162 Pine St Garden City, NY 11530 To: Install accessory generator at existing single family dwelling as applied for. At premises located at: 4295 Vanston Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 111.44-38 Pursuant to application dated 4/20/2022 and approved by the Building Inspector. To expire on 11/25/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-RESIDENTIAL $50.00 Total: $235.00 Building Inspector SO�j��! 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(c-Dtown.southold.ny.us Southold,NY 11971-0959 �QIyCOU IYI�e BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joseph McCartney Address: 4295 Vanston Rd city,Cutchogue st: NY zip: 11935 Building Permit#: 47857 Section: 111 Block: 14 Lot: ,38 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Custom Lighting of Suffolk License No: 38893ME SITE DETAILS Office Use Only Residential X Indoor X Basement Generator X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 20kW Kohler Generator w/Whole House Transfer Switch Notes: Generator Inspector Signature: Date: August 9, 2022 S.Devlin-Cert Electrical Compliance Form t ,� OF SOUIyO� # # TOWN OF SOUTHOLD BUILDING DEPT. °`ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALQv [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM KS: on OAV I da�� �q M Oli Ilk V c r DATE l170kINSPECTOR i OF SOUTyO -- # #. TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] -FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [�e] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: MAL fek DATE Pi �I INSPECTOR ` . M1y 01 ,a a t1 �M� �f •� t y_ 4 _,X Al 10 Groff �t•M� 4 M• K �rt '. .`� tin J � • - �''„ �v �+�• � - �a _�ry7 � 7'� ~� t � sem/ � �j. � .s r�! V5 e `� ',� I�� .* -'�. i_..� ,.. r '•,�..? �r :' � ',� - t����- tib,!-�`,`Y ",+ FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) (O� -------------------------------------- C% r� FOUNDATION(2ND) z o r 1pl ROUGH FRAMING& y -� PLUMBING 1 � W CJS 4- a INSULATION PER N.Y. 2-4 STATE ENERGY CODE Q l n C o FINALCPO -Rpni, ADDITIONAL COMMENTS -bp4-0o-+- c, 5 -00 t kc+r ice r4- 1) �Z m X O o z H d C=7 . b H o��gUfFO(��oGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT 2 Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o• �ao� Telephone (631) 765-1802 Fax (631) 765-9502 haps://www.southoldtownnygv_ f Date Received APPLICATION FOR BUILDING PERMIT Fo2r Office Use OnlyR {�5 APR 19 2022 PERMIT NO. O Building Inspector. BUILDING DEPT. TOWN OF SOUTHOLD Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted.-Where the;Applicant'is not the owner,an Owner's Authorizati n form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: ,— _--- Com( __.__ SCTM #1000- �'� Project Address: Phone#: I .#: 1. (J Email: VY\,C- Cv __ Mailing Address:L(Z�� .CONTACT PERSON: Name: Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Pb C� Phone#: � ---- �� Email:G--�-� CONTRACTORINFORMATION: .- Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION' : eer Structure ❑ ❑ ❑ ❑ Addition Alteration Repair Demolition Estimated Cost of Project: $ 0 D�T1 J Will the lot be re-graded? ❑Ye No Will excess fill be removed from premises? ❑YesNi11 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONO IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage,and storm water issues as provided by. Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name : / ❑Authorized Age Signature of Applicant: Date: CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York SS: No. 01 BU6185050 Qualified in Suffolk County COUNTY OF ) Commission Expires April 14,20)-'j being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I day of Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 g � BUILDING DEPARTMENT-Electrical Inspector f TOWN OF SOUTHOLD 39 Town Hall Annex- 54375 Main Road - PO Box 1179 ' Southold, New York 11971-0959 Telephone (631) 765-1802- FAX (631) 765-9502 roaerr6southoldtownny. ov� seand,@southoldtownnv.aov APPLICATION FOR ELECTRICAL INSPECTION, ELECTRICIAN INFORMATION (All Information Required) Date: to Z2 Company Name: - 7 Name:` License No.: 2) �-ME email: Sal 10 Address: U . t��� Wy _ c Phone No.: i 1. JOB SITE INFORMATION (Ail Information Required) Name:. . U = k �'�e1_\T G Address: Cross Street: L CCCCV'X-t L - {( Phone No.: BIdg.Permit#: email: Tax Map-District:_ 1000 --Section: _ Block: Lot: BRIEF DESCRIPTION OF WORK(Please Print Clearly) Circle All That Apply: Is job ready for inspection?: Y N Rough In Final Do you need a Temp Certificate?: YE NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _ A #Meters Old Meter# . New Service- Fire Reconnect-Flood Reconnect-Service Reconnected- Underground-Overhead #Underground Laterals, 1 2 H Frame Pole Work done on Service? Y N Additional Information::' - PAYMENT.DUE WIT_H_APPLICATION CV Request for Inspection ForinAs >� CP s lav LJo0 _ o L o ' z - � J o Q M 13'-611 o Q 14'-5Y4" PROPOSED DECK AND HOT TUB PLAN PROP ( 9999 SCALE SCALE 3 /8 = 1 0 VANSTON READ . \ \ \ \ \ LAND N/F ANNA DIPAOLA \ \ \ \ \ EXISTING GRAVEL \ DRIVEWAY ---- - -- --- EXISTI \ \ \ C D P 44 \ �\ �..\�� EXISTING LAND N/F FIREPLACE �' FIREPLACE JUSTIN BILLINGHAY XISTING �\ EXISTING 1 �ST�f�Y.\� \ CON RET. �\ ��RA�Ni ELI (\ PROPOSED D REPLACEMENT EXI TING GAR GES: PROP ED zz" HOT \ � EXISTING ISTING PVC FENCE \ PATIO \ EXI G EXISTING C RET. POOL WALL EXISTING P E ING PVC FENCE FENCE i \ so, LAND N/F DANNY PIZZOLA /LAND N/F GLORIA MOLLOY i SITE PLAN SCAL1 / 32 E - 19099 i 04 / r 17 COMPLY WL_LE- L.'. . . c-7 Vr "NEW YORK STATE & :. Iv CODE APPROVED AS NOTED AS REQUIR7 AND CONIDITIONS c. DATE:�a_ � B.P.# �5 SOLI'HOL D T�""fr\ZBA FEE 350-D 8y: SOUTHOL. TINNPLMNINUBOk NOTIFY BUILDING DEPARTMENT AT S0UTH0LD7�WNTRUSTEES 765-1802 8 AM T.0 4 PM FOR THE FOLLOWING INSPECTIONS: N.Y.S.DEC t. FOUNDATION -,TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ,�'U PAN C i�/ OR ALL CONSTRUCTION SHALL MEET THE USE I S U N LAV Y FUL REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR WITHOUT CERTIFICATE DESIGN OR CONSTRUCTION ERRORS. OF OCCUPANCY RETAIN STORM WATER , B=TR=VaP8MW MtP PURSUANT TO CHAPTE,('% OF THE TOWN CODE, ONA V` HLER. Models: 2®RCA(L) Multi-Fuel LPG/Natural Gas 09001 Standard Features SMAW IC®WLER. ® RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. o OnCue@ Plus Generator Management System for remote monitoring is included with the generator. • Kohler Command PRO Engine Features T. t o Kohler Command PRO@ OHV engine with hydraulic valve - Ir lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler® Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High Quality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of a Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental • Extraordinary Reliability Protection Agency(EPA) with both natural gas and LPG. o UL 2200/cUL listed (60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available (60 Hz model). performance and backs that up with a premium 5-year or o Accepted b the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. g • Powerful Performance o Meets 181 mph wind rating. Exclusive Powerboost'' technology provides excellent starting power.§ • Approved for stationary standby applications in locations • Aluminum Enclosure served by a reliable utility source. o Attractive aluminum enclosure allows installation as • 20RCAL models packaged with a Model RXT automatic close as 18 inches from your home or small business.# transfer switch are available. See page 4 and the Model o Enclosure panels can be removed without tools to allow RXT ATS specification sheet. easy access for maintenance and service. • Warranty c, 5-year/2000 hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 2F7 120/240 1 60 18/18 75 20/20 83 100 2 120/208 3 60 17/21 58 17/21 58 70 3 2G7 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 power factor.The standby rating is applicable tovariable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derate 4%per 305 m(1000 ft.)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5°C(10°F)temperature increase above 16°C(600F). Availability is subject to change without notice.The generatorset manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a Kohler®Power Systems professional to calculate your exact residential power system requirements. 'i Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-272 (20RCA) 9/19c Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator a Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field a Self-ventilated and dripproof construction. Leads,quantity 21`7 4 e Windings are vacuum-impregnated with epoxy varnish for 2G7 12 dependability and long life. Voltage regulator Digital a Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H e Digital voltage regulator with±1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed a Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full a Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V, 1 ph 2F7(4 lead) 41 (60 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH 1000 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 8,8:1 Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and filters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 20.2(27.1) Cylinder head material Aluminum Minimum Gas Pipe Size Recommendation,in.NPT Valve material Steel/Stelliteo Pipe Length, Natural Gas LPG Piston type and material Aluminum Alloy m(ft.) 281,000 Btu/hr. 340,000 Btu/hr. Crankshaft material Heat Treated,Ductile Iron 8 (25) 1 3/4 Governor:type Electronic 15 (50) 1 1 Frequency regulation,no load to full load Isochronous 30 (100) 1 1/4 1 Frequency regulation,steady state ±0.5% 46 (150) 1 1/4 1 1/4 Air cleaner type Dry 61 (200) 1 1/4 1 1/4 Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 G4-272 (20RCA) 9/19c Fuel Requirements RDC2 Controller Features, Continued Fuel System o LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position(Model RXT transfer switch Fuel supply inlet 1/2 NPT required) Fuel supply pressure,kPa(in.H2O): o LCD display: Natural gas 0.9-2.7(3.5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent visibility in all lighting conditions Fuel Composition Limits* Nat.Gas LPG o Scrolling system status display: Methane,%by volume(minimum) 90 min. - o Generator set status Ethane,%by volume(maximum) 4.0 max. - o Voltage and frequency Propane,%by volume 1.0 max. 85 min. Propene,%by volume(maximum) 0.1 max. 5.0 max. o Engine temperature o Oil pressure C4 and higher,%by volume 0.3 max. 2.5 max. o Battery voltage Sulfur,ppm mass(maximum) 25 max. o Engine runtime hours Lower heating value, g MJ/m3(Btu/ft3), (minimum) 33.2(890) 84.2(2260) o Date and time displays * Contact your local distributor for suitability and rating derates based o Smart engine cooldown senses engine temperature on fuel compositions outside these limits. o Digital isochronous governor maintains steady-state speed at all loads Operation Requirements a Digital voltage regulation: ±1.0% RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 60Hz o Automatic start with programmed cranking cycle %Load Natural Gas LPG o Programmable exerciser can be set to start automatically on 100 8.0 (281) 3.9 (136) any future day and time,and run every week or every two 75 6.9 (243) 3.1 (109) weeks 50 4.6 (161) 2.3 (82) o Exercise modes: 25 3.6 (127) 1.7 (59) o Unloaded weekly exercise with complete system Exercise 2.0 (71) 1.0 (35) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btu/ft 3) o Loaded full-speed exercise(Model RXT ATS required) LPG conversion factors: 8.58 ft.3=1 Ib. o Front-access mini USB connector for SiteTech- or USB 0.535 m3=1 kg Utility connection 36.39 ft3 =1 gal. • Integral Ethernet connector for Kohler®OnCue©Plus 'Generator Set Sound Data o Built-in 2.5 amp battery charger o Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 64 dB(A) during weekly engine exercise and 69 dB(A) during o Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine,generator, Model RXT transfer switch, programmable All sound levels are measured at 7 meters with no load. interface module(PIM), and load management device. * Lowest of 8 points measured around the generator. Sound levels at o Maintenance reminders other points around generator may vary depending on installation o System settings: parameters. o System voltage,frequency,and phase RDC2 Controller o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability V.U_ge 240V o o ATS position (normal/utility or emergency/generator) Freq: 60.0 Hz o Source voltage and frequency o a O o ATS control (Model RXT ATS required): ' 0 0 o Source voltage and frequency settings o Engine start time delay o_a o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler®Model RXT transfer switch, • Programmable Interface Module(PIM)status displays: programmable interface module(PIM), and load shed kit. o Input status(active/inactive) o Output status(active/inactive) RDC2 Controller Features • Load control menus: o Membrane keypad: o Load status o OFF,AUTO,and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus s LED indicators for OFF,AUTO, and RUN modes G4-272 (20RCA) 9/19c KOHL ����® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery cables ❑ Model RDT ATS e EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load • Critical silencer management board L] Load shed kit for RXT or RDT • Field connection terminal block ❑ Power relay modules (use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) ® Line circuit breaker ❑ Other Kohler@ ATS • Multi-fuel system, LPG/natural gas,field-convertible 20RCAL Model Packages ® Oil drain extension with shutoff valve ❑ 20RCAL with 100 amp RXT with 16-space load center and • OnCue@ Plus Generator Management System NEMA 1 steel enclosure for indoor installation ® Premium 5-year limited warranty ❑ 20RCAL with 200 amp service entrance-rated Model RXT ® RDC2 generator set/ATS controller with combined interface/load management board and • Rodent-resistant construction corrosion-resistant NEMA 3R aluminum enclosure ® Sound-deadening,flame-retardant foam per LIL 94, Warranty class HF-1 ❑ 5-Year Comprehensive Limited Warranty ❑ Available Options 10-Year Comprehensive Limited Warranty Approvals and Listings ❑ CSA approval Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater,240VAC ❑ Cold weather package, 120VAC Generator Set Dimensions and Weights ❑ Cold weather package,240VAC C] Emergency stop kit Generator Set Size,L x W x H: 1x 6x mm (47 47 x 26.2.2 x 32.22.2 in.) ❑ PowerSync@ Automatic Paralleling Module (APM) (single phase only; parallel two 20kW residential generator Shipping Weights: sets with the RD02 controller) 20RCA Generator Set: 252 kg(555 Ib.) 20RCAL with 100 A RXT ATS w/LC 277 kg(611 lbs.) ❑ Programmable interface module(PIM) 20RCAL with 200 A RXT SE ATS: 272 kg(600 Ib.) (provides 2 digital inputs and 6 relay outputs) L �I Fuel System Accessories - ❑ Flexible fuel line(included on CIS models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater, 240 VAC Carburetor heater is recommended for reliable starting H at temperatures below 0°C(32°F) Literature ❑ General maintenance literature kit till W ❑ Overhaul literature kit ❑ NOTE: Dimensions are provided for reference only and should not be used for planning Production literature kit installation.Contact your local distributor for more detailed information. Maintenance DISTRIBUTED BY- ❑ Maintenance kit(includes air filter, oil,oil filter,and spark plugs) O 2018,2019 by Kohler Co. All rights reserved. G4-272 (20RCA) 9/19c