HomeMy WebLinkAbout47689-Z 416, 10/15/2022 Town of Southold 10/15/2022 a P.O.Box 1179 0 N z 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43497 Date: 10/15/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 125 Pasture Ln.,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-17-17.6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/14/2022 pursuant to which Building Permit No. 47689 dated 4/18/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar to existing sinl eg family dwelling as applied for. The certificate is issued to Brandow,Edward&Geller,Georgia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47689 7/14/2022 PLUMBERS CERTIFICATION DATED A riz ignature SO Fat/( Gy TOWN OF SOUTHOLD BUILDING DEPARTMENT C, 1 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47689 Date: 4/18/2022 Permission is hereby granted to: Brandow, Edward 125 Pasture Ln Mattituck, NY 11952 To: Remove existing system and install new roof mount solar to existing sinlge family dwelling as applied for. Disconnects must be located on the exterior, labeled and readily accessible as per code. At premises located at: 125 Pasture Ln., Mattituck SCTM #473889 Sec/Block/Lot# 115.-17-17.6 Pursuant to application dated 3/14/2022 and approved by the Building Inspector. To expire on 10/18/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SOUryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ae sean.deviin�D-town.southold.ny.us Southold,NY 11971-0959 OIyCQUIV 1�,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Edward Brandow Address: 125 Pasture Ln city:Mattituck st: NY zip: 11952 Building Permit#: 47689 Section: 115 Block: 17 Lot: 17.6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy License No: 52689 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: TAW Roof Mounted PV Solar Energy System w/ (20) Qcell 260, IQ4 Combiner, AC Disconnect 40A Fused Notes: Solar Inspector Signature: cL�' Date: July 14, 2022 S.Devlin-Cert Electrical Compliance Form ho��OF SOGTyolo Ll I V El-cy /1, TOWN OF SOUTHOLD BUILDING DEPT. 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION �[ ] PRE C/O [ ] RENTAL REMARKS: Ice-, 0-/<-- DATE INSPECTOR OF SO(/T�OIo # # TOWN OF SOUTHOLD BUILDING DEPT. �o • �o �yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAAUULKING [ ] FRAMING /STRAPPING IV] FINAL 504i-' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: I ��&Ajl hue VVA---.i �p , It -%(,k PU @ L? OV� DATE INSPECTOR w - D - A L SEP 2 8 2022 iLDI TO S e J' i 17 SEP 2. 8 2022 E ILDI TOa i FIELD INSPECTION REPORT DATE COMMENTS , ..0 FOUNDATION(1ST) C ------------------------------------ FOUNDATION(2ND) 1 cn o cn v l •� r ROUGH FRAMING& A y PLUMBING � ' r INSULATION PER N.Y. STATE ENERGY CODE e z • FINAL . v, ADDITIONAL COMMENTS y -Lo it -a � _ � z . m QLl cN z �d b H �= �o�gufFOtK4.9 TOWN OF SOUTHOLD—BUILDING DEPARTMENT y2 Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D PERMIT NO. /�P is Building Inspector: ![ If U MAR Applications and forms must be filled out in their entirety.Incomplete BUILDING DEPT. applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: 0 2— OWNER(S)OF PRO ERTY: Name: SCTM# 1000- 4 Project Address: d /��cv� � 7 r la Phone#: 6' 004;/( Email: - _ i__.. �_y�S d _ -- - Mailing Address: - ---- S. ./04 S ✓� CONTACT PERSON: Name:Danielle Rodger Mailing Address:7470 Sound Ave MattituCk NY 11952 Phone#:6317797993 Email:permits@e2sys.com DESIGN PROFESSIONAL INFORMATION: . Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Element Energy LLC^ Mailing Address:7470 Sound Ave MattituCk NY 11944 Phone#:6317797993 Email:permits@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition [--]Alteration ❑Repair ❑Demolition Estimated Cost of Project: EOtherSolar 30-7, Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 Lono zjign uocument IU:WC;1-Ll 1 HNbU I MH4YU/bU5HAKU/6HUUL3UL12UXUXEUCiHW PROPERTY INFORMATION Existing use of property: esC&P7� Intended use of property:. ���� �17,::;r-e Zone or use district in which premises is situated: Are there any covenan�ts @ nd restrictions with respect to this property? es�(No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by a ter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department forthe Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorizedinspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name) 0-0 le�� � � Cuthorized Agent []Owner Signature of Applicant: Date:( t3//(/1ZZ STATE OF NEW YORK) SS: COUNTY OF �� ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the _ (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me his J V day of. Y 2 No ary Public DEBRA A SEPULVEDA NOTARY PUBLIC,STATE OF NEW YORIL Re&tradonNo.OISFA1269T .PROPERTY OWNER AUTHORIZATION Qumed in My Commission Expires Wh re,the applicant is not the owner) residing at Z2--s do do hereby authorize -� to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 T�>2rr BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �4y��. . 41ti Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrQ,9guttioldtownny. ov seandiWsoutholdtowhgygov �TXzrt�' - APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3�1C)/� Company Name: ¢ Electrician's Name: C� License No.: /17 Elec. email: ,rte, Elec. Phone No: 7,2 Ifl I request an email copy of Certificate of Compliance Elec. Address.: Ur:f'�ri�✓ :/T✓C-. 4 ll 3 - JOB SITE INFORMATION (All Information Required) Name: fac�t/ Address: SJV _Cross Street: Phone No.: 9-377Y 71f-3 - - - -- - - BIdg.Permit#: '1 c�t3-9 _ email: _Tax Map.District;' 1000 Section:/./S610 Block: Q` Lot: 0/ BRIEF DESCRIPTION OF,WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Fooito&: Circle All That Apply: - - Is job ready for inspection?: ❑ YESgINO DRoughin Final Do you need a Temp Certificate?: F] YES PNO Issued On Temp Information: (All information required) Service SizeF11 Ph n'3 Ph Size: A #Meters - Old Meter# ❑New Service Fire ReconnectElFlood Reconnect Oservice ReconnectOUnderground overhead #Underground Laterals 1 2 H Frame Pole Work done on Service'? Y N Additional Information: -- _ - PAYMENT DUE WITH APPLICATION NYSIF New York state Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 lil T J ^^^^" 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 N HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 706281 07/13/2021 TO 07/13/2022 7/15/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO.OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:438572026 oN RK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a. Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 823336604 2. Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Main Rd 3b. Policy Number of Entity Listed in Box"l a" Southold, NY 11971 DBL567527 3c. Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. E] B. Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: ❑K A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. ( t Date Signed 7/15/2021 BywU/ l/ (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111I I III °��°!°°11°°°°1111°11°11°°°�IIIIII ,d► oma® CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/15 021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS.FEDE INSURANCE AGENCY PHONE 631-38b-1 FAX - - 23 GREEN STREET,SUITE 102 E-MAIL Ext: AIC No HUNTINGTON, NY 11743 ADDRESS: ROBERTS. FEDE INSURANCE LA INSURERS AFFORDING COVERAGE NAIC# INSURERA: INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURER C:SHELTER POINT POINT 4 ELEMENT ENERGY SYSTEMS INSURERD: 7470 SOUND AVENUE INSURER E MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: b,bb2 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE g POLICY NUMBER MM/DD MMIDD LIMITS COMMERCIAL GENERAL LIABILITY CL00275204 7/14/2021 7/14/2022 EACH OCCURRENCE $ 3,000,000 X X DAMAGE TO RENTED CLAIMS-MADE � OCCUR PREMISES Ea occurrence $ 100,030 A MED EXP(Any one person) $ 5000 IMA389203 7/14/2021 7/14/2022 PERSONAL&ADV INJURY $ 3000000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY PRO- JECT � LOC PRODUCTS-COMPlOP AGG $ 3000000 POTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATIONPER OTH Y/N - AND EMPLOYERS'LIABILITY 124494445 X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE 7/13/2021 7/13/2022 B OFFICERIMEMBER EXCLUDED? N/A E.L.EACH ACCIDENT $ 1,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2021 1/01/2022 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Southold NY11971 AUTHORIZED REPRESENTATIVEREPRESENTATIVE�,( ber L S. Fade, ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD I powered by r DUO • , YR �Q It TOP EUROPE / Warranty 2 O CELLS product B Pertmmarcz Yield Security T n BREAKING THE 20%EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of �✓V the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` TechnoloV,Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 2 A RELIABLE INVESTMENT 7 Inclusive 25-year product warranty and 25-year 1,- linear performance warranty2. I APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) ]See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.26 in(including frame) (1879mm x 1045mm x 32mm) ]4.0'(1879 mm] 42.8'(1088mm) 15.6'(39a.6mm) Weight 48.5lbs(22.Okg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with 1491'(12EOmm) L anti-reflection technology 1 63-7:7;= _. 4.G-ft9 P01�°016'(4.6mm) F­ Back Cover Composite film 3sr(es6mm) Frame Black anodized aluminum ® 411'(1046mm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes 4bP� a49r(2somm] Cable 4mm2 Solar cable;(+)>-49.2in(1250mm),(-)>-49.2in(1250mm) L. a>D xn.wndo 4 _ Connector Staubli MC4;IP68 •Mwmin9 d-(DETALA]II 1.26'(32mm1 DErNLA 0.83'(Ifimm) 0.96'(24.6mm)I_�I033'18.6 mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-OW) Power at MPP' PMPP [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' VDD [V] 45.19 45.23 45.27 45.30 45.34 .5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' fl [%] >:19.6 ?:19.9 >:20.1 >:20.4 >20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current sc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage VDc [V] 42.62 42.65 42.69 42.72 42.76 'c 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMFP t3%;Isc;Voc t5%at STC:1000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3-1800 W/M2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE vao uo - o e? .e _°° ��Iolmawmmrns At least 98%of nominal power during i first year.Thereafter max.0.5% _ ______________________ degradation per year.At least 93.5% 0100 - - p p -I----- -----I of nominal power up to 10 years.At W u I I I I `z least 86%of nominal ower u to W j I Qeo __________________ ______-______ - ea J 5 25 years. a�a --r-----r-----r----�----- z 2 2 J 0 o o .. All data within measurement tolerant- 'm aDj O6 -'-'__-_'-___'__- 4D I I I I as.Full warranties in accordance with zoo Soo eoo eao 4060 6i a the warranty terms of the Q CELLS o w sales organisation of your respective 1RMDIANCE tW/m�] N 0 6 m u m zs country. 9,d°41ama0m,�bl�0w�m°, YEARS Typical module performance under low irradiance conditions in o W01�°0�p 0tl tl� O°" '0 Im� b R0) comparison to STC conditions(25°C,1000 W/m2) m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of VDc P [%/K] -0.27 Temperature Coefficient of PMPP Y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 D PROPERTIES FOR SYSTEM DESIGN w Maximum System Voltage Vsrs [V] 1000(IEC)/1000(UL) PV module classification Class II o N Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 W Max.Design Load,Push/Pull' [lbs/ft2] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°Fupto+185°F a Max.Test Load,Push/Pull' [lbs/ft] 113(5400Pa)/84(4000Pa) on Continuous Duty (-40°C up to+85'C) a d m 3See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m CNS^/,JI 0 9 Ib H O m UL 61730,CE-compliant, 63'n IEC Quali 5,.20 6.Iled IEC 61730:2C p�-p-J I4aHCl IEC 61215:2016,IEC 61730:2016, U.S.Patent No.9,893,215(solar cells), Tavnnanl�4 Horizontal 76.4in 43.3in 48.Oin 1656lbs 24 24 32 QCPV Certification ongoing. C US packaging 1940mm 1100mm 1220mm 751 kg pallets pallets modules caune4 M1730 wnx.fw.mm '� IR nn2mm a Note:Installation instructions must be followed.See the Installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 961 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready pEnphase IQ 7 Micro'" and Enphase IQ 7+ Micro"' IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'm, Enphase IQ BatteryTM, and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install :,;•' :_; Lightweight and simple Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed EN PHASE 0 - Smart Grid Ready • Complies with advanced grid support,voltage and ELI lci A E3 —i frequency ride-through requirements � - Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com EN PHAS E. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-13-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22V/60V Max DC short circuit current(module Isc) 15A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L--L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com u EN PHAS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 OCCUPANCY an APPROVED AS NOTED USE IS UNLAWFUL L DATE: ��' B.P.# �� T CERTIFICAT- FEE�ta1:9D-6%D BY: OF OCCVp p,,nY NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMING & PLUMBING 3. INSULATION 4. FINAL CONSTRUCTION MUST BE COMPLETE FOR C.O. COMPLY WITH Al. t_ CODES OF ALL CONSTRUCTION SHALL MEET THE NEIA, YORK STATE & TOWN CODES REQUIREMENTS OF THE CODES OF NEW AS REQUIRED AND CONDITIONS OF YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. SOUTL+Q'�zpWNMq SOUTH(, 'OWN PLANNING BOARD SOUTHOLG OWN TRUSTEES N.Y.S.DEC eau.MEMM BRED RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Zoho Sign Document ID:C:UJIJU7BC3TK9VOZHUOSUNW_XXAUFBW_LUBILAYUFWKU Town of Southold March 8th, 2022 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Brandow Residence, 125 Pasture Ln, Mattituck. NY 11952 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.6 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. �Q'��Oo AEG 417 0 Great Eastern Services, Inc. CO PO Box 240 24 Harvey Rd n = W Riverhead, NY 11901 R` 2 3 Office: 631.543.9555 �A,QO SS5 Mobile: 631.235.0189 Email: jerrygiustra@gmail.com Zoho Si n Document ID:COJIJG7BGTK9VOZHQOSONW_XXAQFBW_LOBILAYGFWKO SCOPE OF WORK DESIGNb DRAPING BY: Cutchogue16 ELEMENT ENERGY LLC TO INSTALL A 7.2 KW SOLAR PHOTOVOLTAIC (PV)SYSTEM AT THE BRANDOW RESIDENCE, REVIEW BY J.M.NABCEP CER LOCATED AT 125 PASTURE LANE, MATTUTUCK, NY 1 1 952. 051112-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID No orktG:nt,yCIub THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. T-r'"` °'`2°'"Q 1 rte; REVISIONS r , DE5GRIPTI0N DATE SYSTEM RATING R."A` 03_08_2022 kW STC Mattftuck `' t S"'m ew A- NSuffolk — DC "` EQUIPMENT SUMMARY 8 QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES g ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS *M CONTRACTOR IRONRIDGE XP 100 MOUNTING 5Y5TEM t SHEET INDEX R°°w AL ELEMENT ENERGY. LLC. Pv-2 COVER PROJECT LOCATION MATTTUCK, NY 1195 PV-3 ROOF PV LAYOUT * ` PV-4 STRUCTURAL/DETAILS*SECTIONS LICENSE # 43889-H PV-5 3-LINE ELECTRICAL DIAGRAM LICENSE # 52G69-ME PV-G LA6EL5 N D GOVERNING CODES oF NEw ° � 2017 NATIONAL ELECTRICAL CODE. ,<Q 0 A G� 0 I ® PROJECT NAME 2020 RESIDENTIAL CODE OF NEW YORK STATE. CO �P���. G A5CE 7-1 G AND NEPA-70. L> lltirG. W 270°0 0 90° E j y UNDERWRITERS LABORATORIES(UL)STANDARDS OSHA 29 CFR 1910.269t� = W 240° V 120° LL N ° U LL_J Lf� GENERAL NOTES ��� ,�_ ,�, �� 210°180150 ' w Q O 103443 S —J _ . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 'ORP�' THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE O SSION ( ) } HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK U Z AGREE THE SAME. AERIAL VIEW 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10 CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL 5TAM P Oo NSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND z Lf) ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO N Q JURISDICTION. COMMENCING WITH WORK. I 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE m WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5HEET NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 5PECIFICATION5. CONSTRUCTION. V CO\ E BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE COVER G. ALL ELECTRICAL WORK SHALL UNDERWRITERS APPROVED AND B ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES*REGULATIONS 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND D COMMENCING WITH WORK CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S . 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THI5 DRAW NG ssALe CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON °�It 8. THESE DRAWINGS O ERTYIN5TOf THE E OF SERVICE ARE AND A WEEKLY BA515 OR SOONER IF CONDITIONS WARRANT. DR N .T.5 . D, SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED BUILDING DEPT. PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE TOWN OF SOUTHOLD THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE 3. CONTRACTOR TO THIS PROJECT TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 9. ONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL SHEET NUMBER EXISTING WORK ADJACENT TO HI5 WORK, OR DAMAGED A5 FINAL PAYMENT. PV— I RESULT OF HIS WORK. - TAX MAP: 10001 15001700017031 Zoho Sign Document ID:COJIJG7BGTK9VOZHQOSONW XXAQFBW LOBILAYGFWKO LEGEND DESIGN s DRAFTING BY: o EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL N REVIEW BY J.M.NABGEP CERTIFIED � NEW PV SUB-PANELS 0° 05r - �a A/C DISCONNECT COMBINEROF NEw ' INVERTERS X, �O - ;_�7 GND ELECTRODE PV MODULE 0 A G W27o°Q — RACKING RAIL * �/ 1 * 240' E %A 0 ATTACHMENT POINT =P�� 210° V 120°so° ---RAFTERS O 180. Ooo15o° PROOF PITCH ANGLE 8j SUNRUN METER ZN�O 10344 S ®VENT AFESSIONP� - 0PLUMBING VENT ®SKY LIGHT ®CHIMNEY CONTRACTOR 901 COMPOSITE SHINGLES In GOOD CONDITION Lf POTENTIAL SHADING ISSUES Ll POTENTIAL AS NECESSARY ELEMENT ENERGY. L__ 7470 SOUND AVE MATTITUCK, NY 1 1952 LICENSE # 43889-11 LICENSE # 52G69-ME \\V ?kJJECT NAME 18"FIRE SETBACK @RIDGE W `V 8"FlRE SETBACK @RIDGE U QL C) _3 L. L^/L1 C Z L. D U �i o � � N S v � N Q m G"x 3G"GROUND ACCE55 TYP. - -45'-3" SITE PLHf� 'NOTE 1 .)THE ROOF 5ET5ACK/PATHWAY SHALL NOT BE REQUIRED TO ROOFS WHEN OPP05ING OR DRAWING SCALE ADJACENT ROOF 15 ACCE55 ROOF IN ACCORDANCE WITH R324.G.I EXCEPTION OF 3/ 1 611 = 1 '-0' 2020 NY5 RE51DENTIAL CODE CONSTRUCTION NOTES 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE srEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. �` ,_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R V RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1 000 1 15001700017031 Zoho Sign Document ID:COJIJG7BGTK9VOZHQOSONW XXAQFBW LOBILAYGFWKO LEGEND DESIGN E DRAFTING BY: EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL ®NA/CPV SUB NECTE ��OF NEW� � REVIEW BY J.M.NABCEP CER (�COMBINER . O 051 12-120 INVERTERS ` �P� A_'Gz �Q.G O° -: GNO ELECTRODE I/ ' REVISIONS PV MODULE DE5CRIPTION DATE REV —RACKING RAIL / m = W W270°, X90° ORIGINAL 03-0&2022 0 ATTACHMENT POINT / ��, - V 240° J E _ axc_ �. S ---RAFTERS �O X03443 !` 210° 120° ° � -*--ROOF PITCH ANGLE S A cc 180 ^aA�, °150 SUNRUN METER �O �V`-P ®�T 0PLUMBING VENT ®SKY LIGHT ®CHIMNEY CONTRACTOR ®COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY ELEMENT ENERGY. LLC. 7470 5OUND AVE MATTITUCK, NY 1 1952 LICENSE # 43889-11 LICENSE # 52G89-ME PROJE-, tiAVL I&'FIRE SETBACK(a�R1DGE IB" IRE ETBACK SRI GE W C�1 UzmI W ! 11111 1 , 1 , 111 7- � w C) LuNIJn I I I �D LL► � z oT) ' � Illililiil , � N � m � 'NOTE I .)THE ROOF 5ETBACK/PATHWAY SHALL NOT BE ARRAY#I 18 MODULES REQUIRED TO ROOFS WHEN OPPOSING OR 6"x 36"GROUND ACCESS TYP. 4)'PITCH ADJACENT ROOF IS ACCESS ROOF IN I79°AZIMUTH ACCORDANCE WITH R324.G.I EXCEPTION OF �, SHEET NAME 2020 NYS RESIDENTIAL CODE CONSTRUCTION SUMMARY ROOF DETA. (18)QCELL Q.PEAK DUO BLK-ML G 10+ 400 WATT PV MODULES (DIMENSIONS: 74"X 41 .1"X 1 .3") (1 8) ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS (28)ATTACHMENT POINTS @ 64"O.C. MAX. oKAw;NG SCALE (124.8) LF IRONRJDGE XR100 MOUNTING SYSTEM. ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) 3/ 1 G" = 1 ,-01, CONSTRUCTION NOTES I .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTUPER'5 INSTALLATION INSTRUCTIONS. 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH SHEET NJMBER MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE PV-3 FIELD VERIFICATION. TAX MAP: 1000 1 150017000 17031 Zoho.Si n Document ID:COJIJG7BGTK9VOZHQOSONW_XXAQFBW_LOBILAYGFWKO LOAD CALCULATION ARRAY#I ITEM DESCRIPTION ARRAY# RB Rid- e Beam/Board ti " - MODULE WEIGHT(Lbs) 48.5 R ROOF Rafter C X - �`�`U` - #OF MODULES 18 (D) Decking (P) Pitch a TOTAL MODULE WEIGHT(Lbs) 873.0 (J) Ceilinl Jo 5t REVISIONS TOTAL LENGTH OF RAIL(Ft) 24.8 ��OF NEW y (C) Collar Ties - oes- ��'�" �A' RAIL WEIGHT PER FOOT(Lbs) 0.68 �P 0 A Gj� O� (h) Horizontal Span of(R) V Ale TOTAL RAIL WEIGHT(Lbs) 84.9 * LL= * (R) (RB) - #OF 5TRANDOFF5 28 WEIGHT PER 5TRANDOFF(Lbs) 2 Il G (D) _. TOTAL STANDOFF WEIGHT(Lbs) 56 O 103443__`` TOTAL ARRAY WEIGHT(Lbs) 1013.9 100 POINT LOAD(Lbs) 36.2 CONTRA TOTAL ARRAY AREA(5cl 1`0 385.4 ARRAY DEAD LOAD(Lbs/Sq Ft) 2.6 LEMENT ENERGY, LLC. WINO DESIGN SU1I TO DAMAGE FROM 7470 50UND AVE GROUND SEISMIC VAMM ICEMRRUM YlMicl.000 AIR MEAN I' ;P) .'ATTITUCK, NY 1 1952 SNOWdborne DESIGN Frost DESIGN UNDERLA�Mf%! FREEZING ANNUAL 11 LOADO Imo) T opographic wl.bea uTEGOIer' Weetherfn�' I�. Tennke` Ter► REQU►REOI' "AZARDS INOEIt' TEMW (C) L CEN LICENSE 52G599-ME retw, tone depthe HEAVY _�ZO 20 130 NO NO NO B SEVERE 3 FT MM 15'F YES 599 51`F MANUAL J DESIGN CWERW WiMlf Suawner Attitudedesign Design Heating rat Elevation Latitude head coWbbg Correction factor design temperanwe difference tmperop tooling temperature PROJECT NAMI- 108 FT 41'N 15"F 88`F 1.00 70`F 75`F 55'F _ �H) Coote Wind wins Coincident Daly Winter Sumer _ (J) W CV temperature ddferente velocity velocity wet bulb ralge lwrnldicfr humidityhooting coolling U LU Ln zzm 11'F 15 MPH 7.5 MPH 77 F MEDIUM(M) 40% 32 GR®50%RH [L f Q — For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 Ms. ROOF FRAMING DETAIL LIJi a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth L z strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction V J shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMPO Q U C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined SOLAR MODULE C on a site-specific basis in accordance with Section R301.2.1.4. z Ln e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York STAINLESS STEEL 3/8" N State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND NUT _ Q see Figure R301.2(1).] f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. c g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New / York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the NRIDGE ALUMINUM RAIL) Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: I.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM"L' BRACKET -- ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM FLASHING SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ST RU CTU RA L I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." ASPHALT SHINGLE ROOF j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5/1 G"x G'STAINLESS (Base 32°F)." STEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 I/2"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION SEALED DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the A5 NOTED table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. 0. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 51­1EET NUMBER (') See Figure R301.2(4)B. FV-4 TAX MAP: 1 000 1 15001700017031 MOUNTING DETAIL n Zoho Sign Docu'rnent ID:COJIJG7BGTK9VOZHQOSONW_XXAQFBW_LOBILAYGFWKO 50LAP ARRAY ON MAIN HOUSE 7.2 kW DESIGN a DRAFTING BY: (18)QCELL Q.PEAK DUO ELK ML-G)O+ 400 WATT MODULE-- ELEMENT ENERGY LLC (2)STRINGS OF(9)MICRO-INVERTERS - REVIEW BY J.M.NA5CEP CERTIFIER '(2)STRINGS TOTAL Pi AL 051 1 12-1 29 TO UTILITY GRID pF NEw REV1510N5 STRING # I _ _ _ _ _ ti�.(F. Yp 1 N scwPT10N DATE - - - - - - - _ ENFHA5E �` .R0 '4 (i/� ---------------- - BRANCH W` R . IT -- - - !__ - - -� TERMINATOR �� \ �� BI-DIRECTIONAL GAA 73-08-2022 _ !� I TYPICAL ((� 0 UTILITY METER ET Er *_ -PHASE, 240 V ------------------- ---' ------Ej------ ---- - --- ------ 0m _ Ljj 2 P-ER NEC 24'r.2 Bh 4690.64(A; N�GTn STRING #2 MICRO-INVERTER �O n 103443 V� _EOFAo Oov�u�TORs 240 AE 1071.2PLUA5-72-2-US AR�FESSIONP� 1 _ - - AX. C.OUTPUT POWER 290 VA t N I I 975%CEC-NFIGriTED EFF. ej NEMA G.UL LISTED CONTRACTOR TYPICAL I 1 ENPHASE BRANCH CIRCUIT CABLE TYPICAL ELEMENT ENERGY. LLC. t 7470 SOUND AVE AC D15CONNECT MATTITUCK. NY 1 195 I I I I 50 D D223NR3 LICEN5ff # 43(5(59-HL 240 VAC.60 A 1 I 'vEVA:R.H�. ��s-=- LICENSE # 52489-ME � 1 I t t I 1 I MAIN SERVICE PANEL PROJECT NAME' I N N 1 1 r - ----- ----------------------------------------------------- AC COMBINER BOX I 1 I 21: r;n I NLLJN W m G N 1 _ ) Z E 15TING GROUNDING Z V, ELECTRODE SYSTEM Q I i CLI >_ � D z WIRE CONDUIT SCt1EDULE Q U CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% p-- :DI.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION 51ZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE z Ln 310.)5(5)(3) 31 O 1 5(5)(2ay(3c) �- INVERTERS COMBINER PANEL AWG#10 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I.. 55QC 0.84 1 10 FT 2.917. OR EMT - Q COMBINER PANEL AC DISCONNECT AWG#10 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 25 FT 1.3% C c C- AC DISCONNECT MAIN PANEL AWG#G 3 I T11WN-2 AWG#8 1 THWN-2 CU PVC I" 45QC 0.95 10 FT 0.1% ELECTRICAL NOTES SHEETNAME CALCULATIONS FOR CURRENT CARRYING CONDUCTOR5 I.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NKTL, AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER. RATED FOR GOO V AND 90QC WET ENVIRONMENT. [NEC 690.8(3)(1)]:(Isc)"(#of strm s)'(1.56) = 1 3.6 I A 3-LINE D I A 3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g Modules per String 9 MAX. TO. AND LOCATED A5 CL05E AS POSSIBLE TO THE NEAREST RIDGE. HIP. OR VALLEY. AWG# O. ampacity'Temp Derate = 26.88 A 26.88 A > I 3.6 per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL A, therefore DC wire size is valid. Modules Number of Inverters 18 COMPLY WITH NEC I 10.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25)= 27.23 A Record low temp I OQC FURNISH ALL NECESSARY OUTLETS. SUPPORTS. FITTINGS AND ACE55CRIE5 TO FULFILL AWG#10, ampacity'(Temp Derate)'(Conduit Fill Derate) = 38 A Voc Temp Coefficient -0.24%/QC DRAWING 5CAL APPLICABLE CODE5 AND STANDARDS. 38 A> 27.23 A. therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS -1.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampacity Calculation O eratln Current 0.8 A =(#of sten s)"(Im ) THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output'(I.25)= 27.23 A i `� •T•5 ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G. ampacity"(Temp Derate)"(Conduit F111 Derate) = 7 1.25 A O eratln Volta e 37.13 V =(#modules m series)'(Vm ) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 7 1.25 A > 27.23 A. therefore AC wire size is vand. Max. System Volta6je 49.6 V = (#modules in series)'[(((-#.##%V/QC'.O I)'(Lo Temp## C-25))'(Voc))+(Voc)1 SUPPORT RAIL. PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 13.9 A =(#of stnn s)'(Isc)'().25)per Art. G90.8(A)(1) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEK LUG AC 5Y5TEM SPECIFICATIONS SHEET NUMBER OR IL5CO GBL-4DBT LAY-IN LUG. O.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive negative) Max AC Output Current 27.23 A OR O eratln AC Volta e 240 V PV-5 10.)THE DC 51DE OF THE PV 5Y5TEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35, TAX MAP: 1 000 1 15001700017031 Zoho 5 n Document ID:COJIJG7BGTK9VOZHQOSONW_XXAQFBW_LOBILAYGFWKO SERVICE METER O O I N5TALLATION NOTE o LEN- - ELEMENT;`. - 111 SOLAR PV SYSTEM PHOTOVOLTAIC • • I'• ' • ( I ) ALL LABEL 5HALL BE I N5TALLED I N V EW 6Y J.M. D slI EQUIPPED WITH I BREAKER ACCORDANCE WITH THE 201 7 NEC RAPID SHUTDOWN ® REQUIREMENTS. r�vlsloNs DESCRIPTION DATE REV OPERAPNG •• (2) ALL LOCATIONS ARE APPROXIMATE AND >3-0. 2022 MAX S1,STEM VVDC SOLAR AC LOAD CENTER - OUTSIDEpwraw iDONOTRELOCATETHIS; i SHORTREQUIRE FIELD VERIFICATION. i OVERCIAMa DEVICE ' (3) LABELS, WAKNING(5) AND MARKING 0 O nMRAM SHUTIXftSVNTCHTO ® SHALL BE IN ACCORDANCE WITH NEC T ro y POWIM TO%W WM 1 10.21 (5). } PVSYSI MRVRWJM SH0pCH/L1RD""f' "YAC DISCONNECT CAUTIUN (4) THE MATERIAL USED FOR MARKING —" LacomI"'" MUST BE WEATHER RESISTANT, IN SOLAR AG LOAD CENTER - INSIDE O �.n.��. COMPLIANCE WITH NEC 1 10.2 1 (B)(3). °°"TRACT°R (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® OO ® I I D ARNINGi SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC TM ES QIL�ENrFEDBYMtkT�LE UAL POWER SUPPLY + 7470 SOUND AVE SOURMTOTALRATMCDFALL — COMPLIANCE WITH NEC 690.3 1 . OVERCUR�Ii DEVICES.EXCLUDW SOURCES:UTILITY GRID MATTITUCK, NY 1195: MA"SUPPLYOVERCURRENT AND PV SOLAR LICENSE # 43889-11 DEVICE,SHALL NOT EXCEEDELECTRIC SYSTEM CONDUIT - INSIDE BUILDING cRYOFRILBA LICENSE # 52689-MF O O 0 _ _ , _ ARNING _ 1 WARNING ' THIS SERVICE METER ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM IS ALSO SERVED BY A PROJECT NAMt I COMBINER PANEL = PHOTOVOLTAIC SYSTEM , TERMINALS ON THE UNE AND LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS _ CONDUIT - OUTSIDE BUILDING IN THE OPEN POSITION- LLJ O ® U uu Ln 4 W Q 0 WARNIN - w DUAL POWER SUPPLY �J z ISOURCES:UTILITY GRID AND t PV SOUR ELECTRIC SYSTEM MAIN SERVICE PANEL - OUTSIDE 5 ®CMITmsow, O O � � O O O ACAUTION ® z Ln ELECTRIC SYSTEM CONNECTED N O • • i C C 6 DISCONNECT,AC L MAIN SERVICE PANEL - INSIDE OPERATING OPERATING VOLTAGE VOLTS POWER SOURCE i OUTPUT CONNECTION ! OF NEIV DO NOT RELOCATE THIS ® O OVERCURRENT DEVICE �P 0 A Gies * 4u * LABELS m _\ w AC DISCONNECT/BREAKER Z �O 103443 !`� DRAWING 5--A,IO OO OO O ® Ago ssiN .T.5 50LET NUMB-- PV-G TAX MAP: 10001 15001700017031 'Y Town of Southold March 8th, 2022 r Building Department Town Hall Annex ad 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Brandow Residence, 125 Pasture Ln, Mattituck, NY 11952 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.6 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E.' of NieW Great Eastern Services, Inc. AIX A CO PO Box 240 ey 24 Harvey Rd W Riverhead, NY 11901 2 2 Office: 631.543.9555 �40�034�3NP v Mobile: 631.235.0189 FESS1� Email: jerrygiustra@gmail.com a Zoho Sign Document ID:COJIJG7BGTK9VOZHOOSONW_XXAUFBW_LOBILAYGFWKO SC O I E Of WORK -- — —-- -- -- - - — -- DE51GN 4 DRAFTING BY: Cutchogue ELEMENT ENERGY LLC A 7 �,JLAF JVOLTAIC (PV)SYSTEM AT THE 5PANDOW RESIDENCE, REVIEW BY J.M. IIABCEP CERTIFIE _� ® ED O5 LOCAT�'J AT 125 PASTURE LANE, MATTUTUCK, NY I 1952. I THE POW-FP,GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID North Fork Country Club THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. Fe le_i REVISIONS DESCRIPTION DATE REV Pa SYSTEM RATING kW DC STC Mattituck ' N m' yew5ufrakAve t New Suffolk OF NEW EQUIPMENT SUMMARY P�� o A yo �- CO SPR QCELL Q.PEAK DUO BLK G 10+ 360 WATT PV MODULES sj g,a FNPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS RONRIDGE XR 100 MOUNTING SYSTEM CONTRACTOR o _ � W 5hEET INDEX - m Rob„, N� '-” � �'�' C9� I CLEMENT ENERGY. LLC. PV-2 511TVERTEPLAN �A 703443 �!(� PROJECT LOCATION 7470 SOUND AVE PV-3 ROOF PV LAYOUT ROFESSIONP ✓IATTITUCK. NY 1195 PV-4 5TRUCTURAU DETAILS 4 SECTIONS ! LICENSE # 43889-H PV-5 3-LINE ELECTRICAL DIAGRAM / LICENSE # 52289-ME PV-G LABELS N GOVERNING CODES 00 _ i 2017 NATIONAL ELECTRICAL CODE. ® PROJECT NAME 2020 RESIDENTIAL CODE OF NEW YORK STATE. A5CE 7-1 G AND NEPA-70. W 270°-z=::] 0 90° E y - :.• UNDERWRITERS LABORATORIES (UL)STANDARDS _ r 05HA 29 CFR 1910.209 240° V 1200 Y LI LLQ N 210° 150° U W Ln GENERAL NOTES 180° z Q m 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT S J THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK L Z AGREE THE SAME. AERIAL VIEW 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10 CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP O < _U INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES ~ 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THI5 PROJECT AND FURNISH PROOF OF SAME PRIOR TO z ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. N JURISDICTION. — Q 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOP, CD SAFETY ON THE JOB SITE DURING THE � WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. THI5 SHALL INCLUDE, BUT ARE NOT CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 CONSTRUCTION. COV /F� SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE V L_ G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. 4 CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING NYS CODES 8 REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS D DRAWr1G SCALE CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON ECENEq 8. THESE DRAWINGS AS INSTRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. JUL 1 12022 D N .T.5 . SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR BUILDING DEPT EXTENSIONS TO THI5 PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE TOWN OFSOUTHOLD 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SHEET NUMBER EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV- RESULT OF HIS WORK. TAX MAP: 1000 1 15001700017031 Zoho Sign Document ID:G0JIJG7BGTK9V0ZHUU8UNW_XXACFBW LOBILAYGFWKU LEGEND DESIGN*DRAFTING BY: EXISTING UTILITY METER N ELEMENT NA13ENERGY LL MAIN SERVICE PANEL REVIEW BY J.M. ABCEP CEPTI`.-"_I NEW PV SUB—PANELS 00 051 ) 12-125 A/C DISCONNECT COMBINER INVERTERS -_: REVISIONS GND ELECTRODE W270' DE5CRFTION DATE IREV PV MODULE X90°E RACKING RAIL 240o D ,�200 - 0 ATTACHMENT POINT 210° 150° --- - --- - ---RAFTERS 180. -4--ROOF PITCH ANGLE S �SUNRUN METER ®VENT 0PLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES GOOD CONDITION LPOTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY ELEMENT ENERGY. L. 7470 50UND AVE MATTITUCK. NY 1 1952 LICENSE # 43889-N LICENSE # 52689 PROJECT NAME 18"FIRE SETBACK @RIDGE W 1N 8"FIRE 5ETBACK @RIDGE u , z z m _o QLLJ a/- - m N N m /D_ z Ln SHEET NAME G"x 36"GROUND ACCE55 TYP. OF AEtV SITE PLAN co 'NOTE I .) THE ROOF SETBACK/PATHWAY SHALL NOT BE C7 REQUIRED TO ROOFS WHEN OPPOSING OR e S�jYG DRAWING SCALE ADJACENT ROOF 15 ACCESS ROOF IN fn l!l ACCORDANCE WITH R324.G. I EXCEPTION OF 3/ 1 G" = I '-& 2020 NY5 RESIDENTIAL CODE NCO 1034G3 CONSTRUCTION NOTE5 AROFESS00, 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 5HEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. PV-2 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1 000 1 15001700017031 ZOhO Sign Document ID:COJIJG7BGTK9VOZHUOSUNW_XXAUFBW_LUBILAYGFWKU LEGEND DESIGN t DRAFTING BY: o EXISTING UTILITY METER ELEMENT ®MAIN SERVICE PANEL REVIEW BY13YNY L J.M.NABCEP CERT'' NEW AV SUB-PANELS N 05) 1 )2-120 A/C DISCONNECT Oo COMBINER INVERTERS GND ELECTRODE ' - REVISIONS DE5CRIPTION DATE REV PV MODULE RACKING RAIL W270 , r :« X90°E O ATTACHMENT POINT 240° D 120° -- ---RAFTERS 210° 150° --- -4--ROOF PITCH ANGLE 180° BSUNRUN METER ®VENT OPLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUES j� DTRIM/REMOVE AS NECESSARY ELEMENT ENERGY, 7470 SOUND A�. MATTITUCK. NY I I LICENSE # 43889-H LICENSE # 52489-ME PROJECT NAME 18"FIRE SETBACK @RIDGE 18" IRE ETBACK @RI GE LU N I I I I I I l i lI I T (j LU � Q - -I - / Lu F/N N m D "-' � z N � U Ilii Illllil Il Q Q I III ! IIIIIIIII CI ~ IlliiIIIII i z Ln ---- - C N Q CD 'NOTE THE ROOF 5ETBACK/PATHWAY SHALL NOT BE ARRAY#I REQUIRED TO ROOFS WHEN OPPOSING OR 20 MODULES G"z 36"GROUND ACCESS TYP. a 1'PITCH ADJACENT ROOF 15 ACCESS ROOF IN ZF'°AZIMUT-1 ACCORDANCE WITH R324.G. I EXCEPTION OF 51-IEETNAME 2020 NY5 RESIDENTIAL CODE CONSTRUCTION SUMMARY ��pF NIE�j/ P�,QQF DETA. (20) QCELL Q.PEAK DUO BLK G 10+ 360 WATT PV MODULES �0 A G/ (DIMENSIONS: G7.G"X 4 1 .I"X 1 .3") � P (20) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS (30) ATTACHMENT POINTS @ G4" O.C. MAX. DRAWING SCALE (138.7) LF IRONRIDGE XR 100 MOUNTING SYSTEM. L t rl ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) CONSTRUCTION NOTES NCO ^�o3a�3 ��� 3/ 1 6" — I '-0 1 .) ALL EQUIPMENT SHALL BA E INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. �OFESSIC4 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 5HEET NUMBER MINIMUM NEMA 3R RATING. V FV -3 �_� 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE I FIELD VERIFICATION. TAX MAP: 1000 1 1500170001703I ?oho An Document ID:COJIJG7BGTK9VOZH(�0S0NW XXAUFBW-LUBILAYGFWKO LOAD CALCULATION ARRAY# ITEM DE5CRIPTION ARRAY#I DE51GN 6 DRAFTING BY: RB Ride BearrdBoard ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 43.8 Roof Rafter REVIEW BY J.M.NABCEP CERTIFIE #OF MODULES 20 (D) Deckm 051 1 1 2-129 TOTAL MODULE WEIGHT(Lbs) 876.0 of NEw (P) Pitch 4 1° REV1510N5 P O A 10" D. FIR I G"O.C. .� �O (J) Cellln Joist 2"X TOTAL LENGTH OF RAIL(Ft) 138.7 � G/G (C) Collar Ties 2"X 4' D. FIR 48" Of DESCRIPTION DATE REV MAX. RAIL WEIGHT PER FOOT(Lbs) 0.68 51L ' ��' * (H) Horizontal Span of(RJ 19& TOTAL RAIL WEIGHT(Lbs) 94.3 Bim^ ?;3) #OF STRANDOFFS 30 --- 1 4 XXCE=._eU. tl� WEIGHT PEP STRANDOFF(Lbs) 2 (D) O 703443 TOTAL STANDOFF WEIGHT(Lbs) GO A TOTAL ARRAY WEIGHT(Lbs) 1030.3 �OFESSIONP POINT LOAD(Lbs) 34.3 CONTRACTOR TOTAL ARRAY AREA(5q Ft) 428.2 ARRAY DEAD LOAD(Lb5/5q Ft) 2,4 - - - — -- ELEMENT ENERGY, LLC. WIND DESIGN SUBJECT TO DAMAGE FROM GROUND SEISMIC WINTER ICE BARRIER AIR MEAN 7470 SOUND AVE SNOW Speedd Topographic Special Wideb is DESIGN Frost FLOOD MATTITUCK. NY 1 1 95 LOAD* k wind debris CATEGORV Weatherin line Termite' DESIGN uNDE UIREDhNT HAZARDS FREEZING ANNUAL (C) (mph) effects � TEMP REQUIRED INDEX' TEMP) region' ,, t"' depthb MOD TO LICENSE # 43889-H LICENSE # 52689-ME HEAVY 20 140 NO NO NO B SEVERE 3 FT 15°F ZONE YES FEMA 599 51'F MANUAL J DESIGN CRITERIAn _ Winter Summer AlIndoor titude Design Heating Latitude heating cooling correction factor design temperature cooling temperature temperature difference PROJECT NAME 108 FT 41'N 15'F 86'F 1.00 70'F 75'F 55'F (H Coo;:ng Wind Wind Coincident Dally Winter Summer - (-) N velocity velocity — I� empera[uredifference wet bulb range humidity humidity r`) W Ln heating cooling 11' F 15 MPH 7.5 MPH 72`F MEDIUM(M) 40% 32 GR @50%RH z z For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING Dr--TAIL LLJ a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength [LI z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. — b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction (� shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMP O Q C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)Aj.Wind exposure category shall be determined SOLAR MODULE21 on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York STAINLESS STEEL 3/8" N State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND I I — Q see Figure R301.2(1).] f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. C g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the NRIDGE ALUMINUM RAIL Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: -� I.The accompanying Flood Insurance Rate Map(FIRM), ALUMINUM"L"BRACKET ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM FLA5HING 5HEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." pI I I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) �T I\V C IT U R/ value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32*F)" A5PHALT 5HINGLE ROOF j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5/1 G"X G"5TAIN LE55 (Base 32*F)" STEEL LAG BOLT WITH k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 2 112"MIN THREAD jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5EALED DRAWING 5CALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with WITH GEOCEL 4500 "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) AS NOTE C m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J Or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 5HEET NUMBER (') See Figure R301.2(4)B. FV_4 TAX MAP: 1000 1 1500170001703I MOUNTING DETAIL 1 ?oho Slgn Document ID:G0JIJ(37BGTK9V0ZHQ0S0NW_XXAUFBW-L08lLAYGFWK(J SOLAR ARRAY ON MAIN HOUSE 7.2 kW DE51GJ 4 DRAFTING BY (20)QCELL Q.PEAK DUO BLK-G 10+ 360 WA.-, FV MODULE5 ELEMENT ENERGY LLC ` (2)STRINGS OF ' 0) MICRO-INVF-TER5 1<1'(_1 NEw . REVIEW BY J.M.NABCEP CERT" '(2)STRINGS 4L SOLAR MODULE TYPICAL l/ 05 z- 2e P�P9�O A Go�� TO UTILITY GRID COREVISIONS STRING # I �' � � . � DESCRIPTION DATE - - - ENPHA5E � P- ---------------- - BRANCH BY jr-G 1 2 N . -- c*.A AL TYPICAL TERMINATOR -- �,-�_ Z 0 Lu UTILITY METER _. ------------------- O *_ N rxrE`fe I-PHASE,240 V ------ ------ ------ ------ ------ ------ ------ ------ ------ O 703443 I A�OFESSIOt P 5TRING #2 I I I I CONTRACTOR T- ------- - ENPHASE BRANCH CIRCUIT CABLE TYPICAL ELEMENT ENERGY. I I 7470 SOUND A� AC DISCONNECT MATTITUCK. NY I I LICENSE # 438(5e LICENSE # 52689 ' N 1 I I i I I I I I MAIN SERVICE PANEL PROJECT NAME I M X 1 I A-COMBINER BOX I I N I I W N - W Ln I I I I I EXISTING GROUNDING z v_) -----------� i ELECTRODE SYSTEM Q I j - W 7 LLJ >- L----------------------------------------------------- WIRE CONDUIT 5CHEDULE Q U CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop( Q I.D. # ORIGIN DESTINATION 51ZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE 51ZE TEMP DERATE DISTANCE i 5(5)(3) 31 O.1 5(5)(2a)/(3c) Z Lo (--- INVERTERS COMBINER PANEL AWG#10 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR P, 550C 0.84 1 10 FT 2.9% Q N OR EMT DZ - Q COMBINER PANEL AC DISCONNECT AWG#8 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 0.95 25 FT 1.3% C AC D15CONNECT MAIN PANEL A1NG#6 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 0.95 FT 0.1% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS I )ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATIO'' PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90CIC WET ENVIRONMENT. [NEC 690.8(13)(1)): (Isc) '(#of 5trm s' I.56) = 1 5.1 3 A 3-LINE DIA . 3.)WIRING. CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g ) ( Modules per String 1 O TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 2G. #I O,ampaaty'Temp Derate = 26.88 A 26.88 A > 15 13 A. therefore DC were size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 20 COMPLY WITH NEC 110.26. #2 Inverter Output Wire Ampacity Calculation Record low tem 04C 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 30.25 A P FURNISH ALL NECESSARY OUTLETS. SUPPORTS. FITTINGS AND ACE550RIE5 TO FULFILL AWG#8. ampacity'(femp Derate)'(Condult F111 Derate) = 52.25 A Voc Temp Coefficient %oHC DRAWIHG SCALE APPLICABLE CODES AND STANDARDS. 52.25 A > 30 25 A. therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS 6.)WHERE SIZES OF JUNCTION BOXES. RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampacity Calculation Operatinq Current # ;;f strin N .T, . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Ani e out ut'(1.25) = 30.25 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. p 9 p O eratrn Volta e (#modules in 5erie5)'(Vm ) AWG#6. > 30.ty'(femp thereDerafore Cwire size e i Derate) = 7 I.2 A Max. 5 stem Volta e = (#modules in series 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 7 I .25 A > 30.25 A, therefore AC wire size is valid. y )'[(((-# #, 0I SUPPORT RAIL PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current = # ;- =r - s)'(Isc)'(I 25) e - 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSCO GBL-4DBT LAY-IN LUG Max AC Output Current 10)THE POLARITY OF THE GROUNDED CONDUCTORS IS(postive/negative) OR O eratin AC Voltacle 240 V PV-5 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35, TAX MAP: 1 000 1 15001700017031 ?oho Sign Document ID:CUJIJG7BGTK9VOZHUUSUNW_XXAUFBW_LUBILAYGFWKU DESIGN 6 DRAFT11IG 5Y: SERVICE h,YETER01 0 INSTALLATION NOTE ELEMENTE,ERGYLLC REVIEW BYJ M NABCEF CERriFIED SOLAR PV SYSTEM � PHOTOVOLTAICPHOTOVOLTAIC ( I ) ALL LABEL SHALL BE INSTALLED IN 05� z 2e SOLAR BREAKER N THE 2017 NEC EQUIPPED WITH _ 1 • ACCORDANCE WITREQUIREMENTS. RevlsioNs RAPIDSHUTDOWN D-5�R��-0N ' DATA i-Ev ® (2) ALL LOCATIONS AKE APPROXIMATE AND SOLAR AC LOAD CENTER - OUTSIDE MAX SYSTEM VOLTAGE VDC REQUIRE FIELD VEKIFICATION. DO NOT RELOCATE ICE . (3) LABELS, WAKN I NG(S) AND MARKING f*� )I 4 OVERCItRRENTD=ViCE SHALL BE IN ACCORDANCE WITH NEC OTURN RAPID SHUTDOWN SWITCH TO O I 10.2 I (B) THE`OFF POSITION TO SHUT DOWN 1 PV SYSTEM MD REDUCE CAUTION (4) THE MATERIAL USED FOR MARKING SHOCK HAZARD IN THE AWAY ` AC DISCONNECT POWER TO THIS SERVICE IS ALSO SUPPLIED - - -. - FROM THE FOLLOWING SOURCES WITH MUST BE WEATHER RESISTANT IN DISCONNECTS LOCATED AS SHOWN 7 SOLAR AC LOAD CENTER - INSIDE O ® pT:IRY ME-ER MAH GAR FR COMPLIANCE WITH NEC 1 10.2 1 (B)(3). CONTRACTOR IN THE GARAGE PvaREANER': (5) THE PV SYSTEM CIRCUIT CONDUCTORS �Y �— SHALL BE LABELED INSTALLED IN _LEMENT ENERGY, LLC 1 I . ® O ® 0 IMPARN,11NIGR 7470 SOUND AVE I THIS EQU�IIENrFED BYMULTIPLE DUAL POWER SUPPLY �, COMPLIANCE WITH NEC 690.3 MATTITUCK. NY 1 1952 1 SOURCES.TOTAL RATING OF ALL IOVERCURRENTDEVICES,EXCLUDING SOURCES:UTILITY GRID , LICENSE # 43889-11 MAIN SUPPLY OVERCURRENT AND PV SOLAR LICENSE # 52689 ME DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING aMPAcmoFeusen� - - J . _�. THIS SERVICE METER PROJECT HAVE WARNING ! IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD rjl��!V!!77 PHOTOVOLTAIC SYSTEM ` TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED NOT ADD LLLJ N CONDUIT - OUTSIDE BUILDING —" IN THE OPEN POSITION U W Ln 0 QLU Q 6� i 4 DUAL POWER SUPPLY I PV USOLAR ELECRCES:UTILITY GRID AND I,— �,z TRICS STEM ' Q MAIN SERVICE PANEL - OUTSIDE O :D 5 A CAUTION SOLAR CIRCUIT Q 02 O 05 j_ 4CAUTI0iIIf �! ® Q N < SOLAR ELECTRIC SYSTEM CONNECTED I��i � • ► C © ' • DISCONNECTI CURRENT ANI p S MAIN SERVICE PANEL - INSIDE , ARNING O,ERATINGPERATING ALTAGE VOLTS POWER SOURCE SHEET NAME I OUTPUT CONNECTION �! OF N E'V Y ® O DO NOT RELOCATE THIS ` V OVERCURRENT DEVICE C. �P?,0 A O'p LABELS eY �trG AC DISCONNECT/BREAKER rr - I - 2 DRAWHIG 5CAL IRCEt_O^. 7034 +3 P��� N .T.S O O O OFESSION 5HEET NUMBER PV-6 TAX MAP: 1000 1 1500170001703I