HomeMy WebLinkAbout48097-Z ,11�'gVFfO�L�� �o�o xea-, Town of Southold 10/20/2022 P.O.Box 1179 v _ 1 53095 Main Rd Q�+jJfir Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43522 Date: 10/20/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 100 Birds Eye Rd., Orient SCTM#: 473889 Sec/Block/Lot: 17.-3-6.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/17/2022 pursuant to which Building Permit No. 48097 dated 7/21/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Murray T E Jr&U A Irrevoc Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48097 10/6/2022 PLUMBERS CERTIFICATION DATED A h iz ignature FFA'�foc TOWN OF SOUTHOLD c BUILDING DEPARTMENT TOWN CLERK'S OFFICE o ® SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48097 Date: 7/21/2022 Permission is hereby granted to: Murray T E Jr Irrevoc Trust PO BOX 136 Orient, NY 11957 To: Install roof mounted solar panels to existing single family dwelling as applied for. At premises located at: 100 Birds Eye Rd., Orient SCTM # 473889 Sec/Block/Lot# 17.-3-6.1 Pursuant to application dated 6/17/2022 and approved by the Building Inspector. To expire on 1/20/2024. Fees: SOLAR PANELS $50.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $100.00 Total: $200.00 Building Inspector pf OUjy®�® Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ® a@ sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 C®UbV�19�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Murray T E Jr Irrevoc Trust Address: 100 Birds Eye Rd aka 20075 Main Rd city:Orient st: NY zip: 11957 Building Permit* 48097 Section: 17 Block: 3 Lot: 6.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Island Electrical Corp License No: 37608ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 10.8kW Roof Mounted PV Solar Energy System w/27 Hanwha Q Peak DuoG10- 400W Modules, Combiner Panel Notes: Solar Inspector Signature: Date: October 6, 2022 S.Devlin-Cert Electrical Compliance Form 0F SOUTyOIo TOWN OF SOUTHOLD BUILDING DEPT. °`ycourm,N�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRER TANT CONSTRUCTION [ ] E RESISTANT PENETRATION [ ] E CTRICAL (ROUGH) IV ELECTRICAL (FINAL) 5o1&✓ [ CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: c DATE O (7,02,1,1- INSPECTOR ygcq ��raF SO# # TOWN OF SOUTHOLD BUILDING DEPT. `ycourmN�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIO CAULKING [ ] FRAMING /STRAPPING [ FINAL sp [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: oy--N I L/ DATE LOI ?/?� INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (1ST) ------------------------------------ � � C OUNDATION (2ND) ` z ® o _ZFZ,� � y ROUGH FRAMING& PLUMBING c �► r INSULATION PER N.Y. y STATE ENERGY CODE 5 A < L �� IL FINAL ADDITIONAL COMMENTS m c- X b � O a H d �J ro H to 40. TOWN OF SOUTHOLD—BUILDING DEPARTMENT. Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 y�o• ��04 ' Telephone(631)765-1802 Fax(631)765-9502 hups://www.southoldtownnv.Qov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. - 7 oo—q ll Building Inspector:_�� JUN 7 2 029 Applications and forms must be filled out in their entirety.Incomplete BUILDING DEPT. applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: 6/16/2022 OWNER(S)OF PROPERTY: Thomas Murray Name: Thomas M rra )O� SCTM#1000- 017.00-03.00-006:001 Project Add 5s: 075 MAIN R , Phone#: 6313233864 Email: tu2316a@gmail.com Mailing Address: 20075 MAIN RD,ORIENT, NY 11957 CONTACT PERSON: Sung Lee Name: Momentum Solar Mailing Address: 45 Fairchild Avenue, Plainview NY 11803 Phone#: 5162185824 Email:permitsli@momentumsolar.com DESIGN PROFESSIONAL INFORMATION: Name: Mina A.Maker Mailing Address: 3096B Hamilton BLVD,South Plainfield NJ 07080 Phone#: 7329026224 Email: mmakar@momentumsolar.com CONTRACTOR INFORMATION: Name: Momentum Solar(Sung Lee) Mailing Address: 45 Fairchild Avenue,Plainview NY 11803 Phone#: 5162185824 Email: permitsli@momentumsolar.com DESCRIPTION OF PROPOSED CONSTRUCTION []NewStructure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ®Other Solar Panels $ 16,000 Will the lot be re-graded? "❑Yes ❑No Will excess fill be removed from premises? []Yes El No 1 PROPERTY INFORMATION Existing use of property: Single Family Residence Intended use of property:Single Family Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes I]NO IF YES, PROVIDE A COPY. ❑ Check Box After Reading:-The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): �� C'� 112Authorized Agent, ❑Owner Signature of Applicant: Date: Katherine Welsburg STATE OF NEW YORK Notary Publlo,State of Now York Rog,No.01WE6303986 SS: Qualified In Nassau County COUNTY OF Nassau ) Commission Expires December 3,2022 Sung Lee being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor;Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application-are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth-in-the application file therewith. Sworn before me this I day of� 20 Notary Public PROPERTY OWNER-AUTHORIZATION (Where the applicant is not the owner) I, Thomas Murray residing at 20075 MAIN RD,ORIENT,NY 11957 do hereby authorize Sung Lee to apply on my behalf to the T wn of Southold Building Department for approval as described herein. ` 6/16/2022 Owner's Signature Date Thomas Murray Print Owner's Name 2 ILDING DEPARTMENT-Electrical Inspector .1; %o TOWN OF SOUTHOLD o et�oQ�K &n Hall Annex- 54375-Main Road - PO Box 1179 rrs gu G� Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro-gerr@southoldtownnv:gov seandCa�southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/16/2022 Company Name: ISLAND ELECTRIC CORP Name: JEFFREY MARINELLO License No.: ME-37608 email: PERMITSLI@MOMENTUMSOLAR.COM. Address: 76 KERRIGAN,STREET,LONG BEACH, NY 11561 Phone No.: 516-218-5824 JOS SITE INFORMATION (All Information Required) Name: Thomas Murray Address:20075 MAIN RD,ORIENT, NY 11957 Cross Street: MAPLE LN Phone No.: 6313233864 Bldg.Perrnit#:_ '-7 email: tu2316a@gmail.com Tax Map District: 1000 Section: 017.00 Block: 03.00 Lot: 006.001 BRIEF DESCRIPTION OF WORK (Please Print Clearly) INSTALLATION OF SOLAR PANELS; ROOFTOP RAILLESS GRID TIED,XMODULES QkMrj�)J era +o 7 J`l w - Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued-On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A. #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected- Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals 1 voRK Workers' CERTIFICATE OF ST Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Momentum Solar,LLC 732-902-622.4 45 Fairchild Ave Plainview,NY 11803 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 271242539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Zurich American Insurance Co 3b.Policy Number of Entity Listed in Box"1 a" Town of Southold WC 4479937-01 53095 Middle Road Southold,NY 11971 3c.Policy effective period 03/14/2022 to 07/21/2022 3d.The Proprietor,Partners or Executive Officers are Qx included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"'I a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? DYES xZNO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,If the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Lisa MacDonald rt �.%%n�orfyauthorized representative or licensed agent of insurance carrier) Approved by: L ) �tSa 4/19/2022 (Date) Title:Account Executive Telephone Number of authorized representative or licensed agent of insurance carrier: 732-504-2001 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to Issue it. C-105.2(9-15) www.wcb.ny.gov Workers' Compensation Law Section 57. Restriction on issue of permits and the entering into contracts unless compensation is secured. 1. The head of a state-or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute,requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by-an insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(9-15)REVERSE ,acoR�® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDNYYY) 04/19/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald AAI CISR NAME: Brown 8 Brown Metro,LLC (AIH NEO Ixt: (732)504-2001 ac No): (732)504-2011 2000 Midlantic Dr,Suite 440 E-MAIL SS: Lisa.MacDonald@bbrown.com DDRE INSURER(S)AFFORDING COVERAGE NAIC# Mt Laurel NJ 08054 INSURERA: Colony Insurance Company 39993 INSURED Zurich American Insurance Company 16535 INSURER B: P Y Momentum Solar LLC INSURER C: Evanston Insurance Company 35378 (formerly known as Pro Custom Solar LLC) INSURER D: 45 Fairchild Ave,Suite B INSURER E: Plainview NY 11803 INSURER F: COVERAGES CERTIFICATE NUMBER: 22-23 NY Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD MMIDD LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE ❑X OCCUR DAMAGE T RENTED 250,000 PREMISES Ea occurrence $ X Pollution$1,000,000(claims made) MED EXP(Anyone person) $ 10,000 A X Professional$1M(claims made) PACES4257993 04/21/2022 04/21/2023 PERSONAL BADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY II PRO ❑ 2,000,000 JECT LOC PRODUCTS-COMP/OPAGG $ POTHER: Per Proj Agg Cap$5M Deductible $ 50,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 2,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED BAP 1873088-02 04/21/2021 07/21/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED �/ NON-OWNED PROPERTY DAMAGE AUTOS ONLY /� AUTOS ONLY Per accident $ UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5,000,000 C X EXCESS LIAB CLAIMS-MADE MKLV4EFX103881 04/21/2022 04/21/2023 AGGREGATE $ 5,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICERIMEMBER EXCLUDED?and ❑ If yes,describe undN/A E.L.EACH ACCIDENT $ (Mandatory in E.L.DISEASE-EA EMPLOYEE $ er DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Excess Limits Clarification CGL$5M xs$1M C MKLV4EFX103881 04/21/2022 04/21/2023 Auto$4M xs$2M DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Middle Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Additional Named Insureds Other Named Insureds Momentum Solar Energy Services LLC Momentum Home Services Holdings Company LLC Momentum Roofing and Solar LLC OFAPPINF(02/2007) COPYRIGHT 2007,AMS SERVICES INC YORK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Board PART 1. To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier la. Legal Name&Address of Insured(use street address only) Sb.Business Telephone Number of Insured Pro Custom Solar LLC 732-902-6224 DBA Momentum Solar 3096 Hamilton Boulevard 1c.Federal Employer Identification Number of Insured South Plainfield, NJ 07080 or Social Security Number Work Location of Insured (Only required if coverage is specifically 27-1242539 limited to certain locations in New York State,f.e.,a Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Metropolitan Life Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"la" 54375 Route 25 234439 Southhold, NY 11971 3c.Policy effective period: October 1,2021 to September 30,2022 4.Policy provides the following benefits: ® A. Both disability and paid family leave benefits. ❑ B. Disability benefits only. ❑ C. Paid family leave benefits only. 5.Policy covers: ® A. All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B. Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits and/or Paid Family Leave Insurance coverage as described above. p Date Signed: September 21,2021 By: (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number: 678-319-1603 Name and Title: Suzy Davis,State Plan Consultant IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail It directly to the certificate holder. If Box 413,4C or 58 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2. To be completed by NYS Workers'Compensation Board(Only if box 4C or SB of Part 1 has been checked State of New York Workers'Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied With the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed: By: (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number: Title: Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fon»DB-120.1. Insurance brokers are NOT authorized to Issue this form. DB-120.1 (10-17) Additional Instructions for Form DB-120.1 By signing this form,the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"1 a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law.The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box.2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a)The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1(10-17)Reverse ► ;' , I Labor, :Li n o � �� �r 4 MAS 11 TEEL E C-.- T . C:.,A;I-, I. .E ' E. �.� ,n . Thiscert-f. fit .t I b the ���� ;� � s U,fflk. eat0:5/24/2005, �.:.,. Suffolk County Dept. of Labor, Licensing & consumer Affairs 5'.ry HOME IMPROVEMENT LICENSE Name SUNG LEE Business Name Thic rQrtifiAc that thin bearer is duly licensed PRO CUSTOM SOLAR LLC D BA by the County of suffolk License Number: H-57578 Rosalie D rago Issued: 10/06/2016 Commissioner Expires: 10/01 /2022 Fa• iECEHE SEP 2 3 2022 _- t IJILDIK" `t-. ....CC Mina Makar Engineer-PE Mina Makar Engineer-PE Pro Custom Solar LLC 732-902-6224 Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd June 1,2022 3096B Hamilton Blvd June 1,2022 South Plainfield,NJ 07080 South Plainfield,NJ 07080 Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria Thomas Murray Structural Design Loads per ASCE 7-16 20075 MAIN RD ORIENT,NY 11957 Dead Loads=10 psf+2.6 psf(new solar panels)=12.6 psf Roof Live Load=20 psf Dear Plan Reviewer: Ground Snow Load/Live Load=30 psf Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation Wind Load Calculation Criteria when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-16,Ch.30.4 Regarding the solar panel array installation on the above referenced project please note that an inspection was Design wind pressure determined by Eq.29.4-7: performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was Zone I=-40 psf Roof Slope=23 degrees Roof Mean Height=15 ft conducted.There is adequate structural capacity for the installation of the array with the following recommendations: Zone 2=-51.9 psf Basic Wind Speed=120 mph Zone 3=-59.9 psf Exposure=C 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x8"wood rafters @16"o.c. spanning 8'4"with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf.overall to the roof.The existing structure is sufficient to support the new loads associated With the additional weight&wind Per section 2.4.1,ASD combo=D+0.6W: resistance.No additional structural support is required for the roof structure. Zone 1=2.6 psf+0.6(-40 psf)=-21.4 psf Zone 2=2.6 psf+0.6(-51.9 psf)=-28.5 psf 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed Zone 3=2.6 psf+0.6(-59.9 psf)=-33.3 psf instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as Check Attachment to Wood Rafter specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter summary table below: Lag Screw Spacing: Lag Screw Tributary Area: Roof Type: Shingle Fastener Max Spacing(in.) Zone 1= 48"o.c.max Zone 1=(48"o.c.max)^2/144=16 SF Attachment System: "ROOFrECH^®RT-APEX Wind Zone 1 Wind Zone 2 Wind Zone 3 Zone 2= 32"o.c.max Zone 2=(32"o.c.max)^2/144=7.11 SF Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 32 32 Zone 3= 32"o.c.max Zone 3=(32"o.c.max)^2/144=7.11 SF embedment of 3"into the rafters 3.Solar Modules shall be UL,1703 rated.Refer to manufacturers specifications sheets. Lag Screw Forces: W=2661b/in(Table 12.2A,2015 NDS) 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Zone 1=21.4 psf x 16 SF=342 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) 5.All aspects of the installation shall comply with the 2020 Residential Code of New York State,ASCE-7-16,2017 Zone 2=28.5 psf x 7.11 SF=203 lb < W', OK Ct=1(Table 2.3.3,2015 NDS) National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 3=33.3 psf x 7.11 SF=237 lb < W', OK W'=W x embed x Cd x Ct law. W'=266 lb/in x 3 in.x1.6 x 1=1276.8 lb 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. ,-,-OF NEw G.) Ay P����P ' Mgd"q�1O 42L r CLI Mina Makar,P.E. C) c� NY.Lic.No.104468 = 2S�O 104468 A'�OFESSION�� L PLAN KEY SYSTEM INFORMATION THE RESPONSIBLE'LICENSED DESIGN PROFESSIONAL SHALL PV-1 . COVER PAGE MODULE HANWHA Q.PEAK DUO BLK ML=G10+'400 . PROVIDE A SIGNED'AND SEALED LETTER-CERTIFYING THE PV-1(2) COVER PAGE.CONT. _ _ _ INSTALLATION WAS INSPECTED ANDCONFORMSTO THE m INVERTER ENPHASE IQ7PLUS:72 2 US .. mOmentU PV=2: .. ;;•PANEL LAYOUT • : OF THE 2020 NY ULD RACKING >;-:ROOFTECH RT=APEX SIDENTIAL.CODE::'[HIS,INSPECTION SOLAR PLANS'AND REQUIREMENTS CODE AND NYS RE ELECTRICAL AND CERTIFICATION LETTER BE PERFORMED AFTER PV-3 SYSTEM SIZE(DC) 10.8 KW INSTALLATIONS ARE COMPLETED AND SHALL.BE SUBMITTEDPRD CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-4 EQUIPMENT LABELS TO THE BUILDING-DEPARTMENT PRIORTO SCHEDULING'OF 3096 HAMILTON BLVD.BUILDING 8,S.PLAINFIELD,N3 LOCATION . .41.1438098;:72.3117572 FINAL INSPECTION: (732)902-6224,MOMENTUMSOLAR.COM. .PROFESSIONAL ENGINEERING .THE UL-CERTIFICATE OF•ELECTRICAL INSPECTIONS SHALL • BE SUBMITTED TO THE BUILDING:DEPARTMENT PRIOR TO', C O f NEN/' GENERAL NOTES: SCHEDULING OF FINAL INSPECTION.` ` A• �'O . THIS PV SYSTEM HAS.BEEN DESIGNED TO MEET.THE,MINIMUM DESIGN STANDARDS FOR,BUILDING'AND OTHER.STRUCTUJRES OF THE ASCE 7-16,:2020 NYS BUILDING CODE AND 2020 NYS RESIDENTIAL CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCESce n. . AN 18" WIDE (FREE OF SOLAR EQUIPMENT)SHALL BE PROVIDED ON BOTH SIDES OF THE ROOF. NOT FEWER THAN TWO PATHWAYS; ON SEPARATE ROOF.PLANES FROM ul LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36 INCHES.(914 MM):WIDE; FO 04468 SHAL(BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN SHALL-BE PROVIDED ON THE E S REET OR DRIVEWAY SIDE OF THE ROOF.-F. FOR EA HAROOF PLANE p�O *E..sl P� WITH APHOTOVOLTAIC.ARRAY,A PATHWAY NOT LESS THAN 36 INCHES WIDE (914 MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME MINA A.M6224 30968 HAMILTON BLVDSOUTH,PWNFIELD,NI07080 ROOF PLANE'AS THE PHOTOVOLTAICARRAY, ON AN ADJACENT ROOF PLANE, OR ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND STRADDLING THE SAME AND ADJACENT ROOF PLANES. ALLATON SPAN TTTA LOAD CALCULATIONS TO MEET LOCAL AND"A`STATEBUILDING CODES& OES& COMPLIANCE.WARNING.THAT IT IS A VIOLATION OF.THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. . SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL.TO AND NO MORE THAN 67INCHES ABOVE THE SURFACE OF THE'ROOF. BILL OF MATERIALS . CUSTOMER INFORMATION WEIGHT OF.THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR MODULES 27 THOMAS HURRAY-MS101318 PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL• SOLAR HOT WATER INVERTERS 27 ' SYSTEMS. 20075 MAIN RD ROOFTECH BASE. 92 ORIENT,NY 11957 ANY PLUMBING VENTS ARE NOT-TO BE CUT OR:COVERED.FOR SOLAR EQUIPMENT 6313233864 INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A ' MID CLAMP 46 JURISTICTION:SUFFOLK PLUMBING PERMIT AND INSPECTION. END CLAMP : 38 UTILITY:PSEGLI UTILITY ACCT#: INVERTER PLACEMENT: END SPLICE, 8 UTILITY METER#: END FLOATING.SPLICE , . . 8 SYSTEM UTILIZES "EN PHASE".MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE: MID.FLOATING SPLICE _. 14.' PV SYSTEM BUILDING•REVIEW NOTE: SKIRTS 11 INFORMATION .'.ENPHASE COMBINER BOX 1 SYSTEM SIZE(DC):10.8 KW TOWN BUILDING PLANS:EXAMINER HAS.RECEIVED THE ENCLOSED DOCUMENT FOR SOLAR AC DISCONNECT 1 YSTEMSIZE.(AC.):7.83 KVA MINIMUM ACCEPTABLE PLAN SUBMITTAL'REQUIREMENTS OF THE TOWN AS SPECIFIED MODHANWHA Q.PEAK DUO BLK IN THE BUILDING AND/OR RESIDENTIAL.CODE.OF THE STATE OF NEW 7 ULES:_ 50A OCPD,YORK. . 1 LMOD A +400.-. THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE.THAT 125A LINE TAPS Z . SAFE HARBOR MODULES:0) RESPONSIBILITY IS GUARANTEED,UNDER THE SEAL AND SIGNATURE OF THE NEW. 7 INVERTERS:ENPHASE IQ7PLUS-72-2-US - YORK LICENSED DESIGN PROFESSIONAL OF RECORD.THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS.AN ATTESTATION THAT,TO THE BEST OF THE LICENSEE'S PR03ECTINFORMATION. . . BELIEF AND INFORMATION,THE WORK IN, DOCUMENT IS: INITIAL DATE:,6/2/2022 DESIGNER:NIA 1. ACCURATE REV: DATE: DESIGNER• 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE REV'' DATE:. DESIGNER: SUBMISSION. . . 3. CONFORMS WITH REASONABLE.STANDARDS OF PRACTICE AND WITH VIEW TO. COVER PAGE THE'SAFEGUARDING OF LIFE,.HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE: . Phi- 1 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP ROOFS Rl�o RT-APEX CONSIDERED FROM AN ANGLE OF MIN.9.5°(j)TO MAX.45' (jj)NOT TO EXCEED The standard for rail-less PV momentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THEPEX mounting MANUFACTURER. The most Rail-less&Self-flashing _ Installation Item&Part Number SOLAR 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE advanced Mounting kslaNBnapgEradrnp swdx,kauRwp �trAVExsa�(RT3oo-veK) MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE MANUFACTURER. ♦ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR ` >.. � 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N3 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 '' a •-_- - RT-Apex Base 24 ea (732)902-6224,MOMENTUMSOLAR.COM 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH ``_„��+.r 48 el PROFESSIONAL ENGINEERING MANUFACTURERS PRINTED INSTRUCTIONS. �—- airy zea MdOS O-w(RT3-02-UM-BK) MMe Nn6p Spice(RT3-02-UMFSBK) r�CMM Spica(RT3-02-UMSBK) 0[ NE 1,- � L40NMa tldnp:12 wfiwMST3-Q2_ 7A I NYdM Nrb(RT3-0211ESBK)) APEX EUNo (RT3-02-UESBK)SkM end End Splice Skirl arW End Gamp End Clam,12 N. 2v1 RT-APEX Skirt(RT7-03-SKWBL) Universal Clamping/Slide In Mounting FO 104,468 One Step Leveling/ Integrated Flexible Flashing One step leveling ! p��FESSIONP� mounting since RT-Apex Skin ftncn:N ea. Proven PV tin si1994 "M _ 3• ����) Mme•a_i oexripno. ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS �� (75rnm) ala P A , , m MINA AS PER ASCE 07-16. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C,&D AND ROOF rd, 3096E HAMILTON TER ATTACH D HASIELD,N]070IO c u, •� --- --- -- ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND Hard.— St �eei AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, CCES—l' Fnt"-tek -Fl„mk5we knked Aa,. ESR 3slsi AT TO MEET LOCAL AND STATE BUILDING CODE RIDGE,OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. nr'PA""*ed """ COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 3 t� T PFNN� ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A _ LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAV, chRoof Tech Inc. GUTTER GUTTER • •• • ° •• - wwv.ioof-tech.us info@roof-tech 10620 Treena St.suite 230,San Diego,CA 92131 ® © 10 w CUSTOMER INFORMATION THOMAS MURRAY-MS101318 ® 2 ® RIDGE RIDGE ® ® ® O ® 20075 MAIN RD ® ® ® ® ORIENT, NY 11957 y6o 6313233864 w Y JURISTICTION:SUFFOLK 90 © UTILITY: PSEGLI UTILITY ACCT#: © ® GUTTER ® GUTTER © UTILITY METER#: STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEN PV SYSTEM ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-JOIST SPANS. SYSTEM SIZE(DC): 10.8 KW TABLE R301.2(l) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW SYSTEM SIZE(AC):7.83 KVA 7 MODULES: HANWHA Q.PEAK DUO BLK YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERI L-G10+400 GROUND SNOW LOAD(LBS/SF) 25 OF THE TOWN. SAFE HARBOR MODULES:0) SPEED (MPH) 130 27 INVERTERS: ENPHASE IQ7PLUS-72-2-US TOPOGRAPHIC EFFECTS B PROJECT INFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 1129.95 LBS SPECIAL WIND REGION NO INITIAL DATE:6/2/2022 DESIGNER:MA TOTAL NUMBER OF ATTACHMENT POINTS 84 WIND BORNE DEBRIS ZONE 2 REV: DATE: DESIGNER: EIGHT PER ATTACHMENT POINT 13.451785714285SEISMIC DESIGN CATEGORY C HANWHA Q.PEAK DUO BLK ML-G10+ 400 REV: DATE: DESIGNER: 7 LBS 400 WATT MODULE TOTAL SURFACE AREA OF PV MODULES 489.78 SQFT CLIMATE ZONE 4A 74" X 41.1" X 1.2C" COVER PAGE I F WIND EXPOSURE CATEGORY B (SEE DATASHEET ISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT PV— SCALE' 1/16" = 1�-0" ROOF MODULE COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN PORTRAIT MAX SPAN ' ROOF AREA 1/2/3) (ROOF AREA 12 3 R1 14 23' 171' 80% 67/67/67 39/39/39 R2 13 23' 351' 73% momentum 67/67/67 39/39/39 SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING P,,t pf NEw yo MA�q��� GROUND ACCESS (TYP) ac r DRIVEWAY FIRE SETBACK W 0� �� (18" VENTILATION, Z a _ 36" ROOF ACCESS) ��FO 104468 P, (NP) � a a ! 47 . MIN RoFESSIA. - 3096B HAMILTON SLVDSOUTH PLAINFIELD,N)07080 / ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& V-6" / I , , ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. C�JTTER / CUSTOMER INFORMATION 3'-0" THOMAS MURRAY-M5101318 20075 MAIN RD U ORIENT, NY 11957 z (J Ars EXTERIOR 6313233864 W ce Ac sP ❑ 1URISTICTION:SUFFOLK W DISC SYMBOL LEGEND UTILITY: PSEGLI Z Q EXTERIOR INTERIOR 0 UTILITY ACCT#: LL ❑ I0 MSP MAIN SERVICE PANEL 5 1 � CHIMNEY UTILITY METER#: z ELECTRICAL EQUIPMENT J� Of SP SUB-PANEL j SKYLIGHT \�f PV SYSTEM OMUTILITY METER X I VENT INFORMATION ❑ „// V —SYSTEM SIZE(DC): 10.8 KW CB AC COMBINER BOX/AC p PIPE VENT SYSTEM SIZE(AC):7.83 KVA Dlsc DISCONNECT 7 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+400 uDC UTILITY DISCONNECT FAN SAFE HARBOR MODULES:0) 7 INVERTERS: ENPHASE IQ7PLUS-72-2-US LC LOAD CENTER _ d/ SATELLITE DISH =� PROJECT INFORMATION N3R NEMA 3R BOX W/ENVOY-S FIRE SETBACKS INITIAL DATE:6/2/2022 DESIGNER:MA REV: DATE: DESIGNER: H_ B COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: PF PERFORMANCE METER PITCH DIRECTION PANEL LAYOUT MODULE PV-2 27 HANWHA Q.PEAK DUO BLK ML-G10+400 40OW MODULES PAIRED WITH 27 ENPHASE IQ7PLU5-72-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUIT A 13 MICRO-INVERTERS EXISTING MURRAY 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B UTILITY SUB PANEL 240 V 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 7 MICRO-INVERTERS METER (732)902-6224,MOMENTUMSOLAR.COM BRANCH CIRCUIT C MAIN BREAKER:200A 7 MICRO-INVERTERS ENPHASE 80A AC GRID PROFESSIONAL ENGINEERING +B _ +B _ +B _ COMBINER BOX N F.��oEW W/ENVOY IQ r ISI ■ ■ . _ ©�- 89L AC DISCONNECT 200A P A• M,4 P , O LINE SIDE $ HOT TAP $ A n W ROOF10A/15A BREAKER POWER Z JUNCTION (MANUFACTURER SUPPLIED 50A OCPDGROUND 104468 FOR ENVOY) TO O V TERMINATION CAP 1 BOX 2A-C (COMMUNICATION) 3 4 GENERATOR A, GENERATOR INSTALLED ON 20A BREAKER(A)(PV) �P�FESS1 END OF CABLE 20A BREAKER(B)(PV) TRANSFER 20A BREAKER(C)(PV) SWITCH MINA A.MAK, 30968 HAMILTON BLVDSOUTH PIAINFIELEL D,N]07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC (NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOLAR DBA MOMENTUM SOLAR MARINELLO, 902-6224 ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 3096REY HAMILTON BLVVD.732)BUILDING 0,SOUTH PLAINFIELD,NJ 07080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8.GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER INFORMATION PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. THOMAS MURRAY- MS101318 BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS 20075 MAIN RD DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. ORIENT, NY 11957 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH 6313233864 89L LESS THAN 10FT TO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM INFORMATION Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire SYSTEM SIZE (DC): 10.8 KW Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type SYSTEM SIZE (AC):7.83 KVA 7 MODULES: HANWHA Q.PEAK DUO BILK 1 OPEN AIR 2 12 AWG Trunk Cable 90"C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable VII L-G10+400 SAFE HARBOR MODULES:0) 2A 3/4" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 27 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2B 3/4" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 7 1.21 1.25 10.59 08 AWG THWN-2 PROJECT INFORMATION 2C 3/4" PVC 2 10 AWG THWN-2 90"C 40 0.96 0.8 30.72 7 1.21 1.25 10.59 08 AWG THWN-2 INITIAL DATE:6/2/2022 DESIGNER:MA REV: DATE: DESIGNER: 3 3/4" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 27 1.21 1.25 40.84 08 AWG THWN-2 REV: DATE: DESIGNER: 4 3/4" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 27 1.21 1.25 40.84 08 AWG THWN-2 ELECTRICAL PV-3 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY OCAUTION:AC SOLAR VOLTAGE 12 AC CONDUITS ENCLOSURES/WALLS/ PARTITIONS/CEILINGS/FLOORS momentum OR NO MORE THAN 10' t''�°u F r..-a- b. E SOLAR © • 1 COMBINER BOX 1 AT ANY COMBINER BOX . PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR • • • • •�.. • - - - 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N) (732)902-6224,MOMENTUM SOLAR.COM PROFESSIONAL ENGINEERING AWARNING �oF NEW �P A. © ELECTRICAL SHOCK HAZARD f.� p. Mq TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX © LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION r � PV SYSTEM AC DISCONNECT4! AWARNING = RATED AC A _ - �` 104468 A ELECTRICAL SHOCK HAZARD --;==_ •OUTPUT OPERATING , TERMINALS ON BOTH LINE AND =`� _-_=- SSIONP AC VOLTAGE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION O CAUTION 1 OF EACH AT FUSED AC 30968 HAMILTON BLVDSOUTH PLAINFIELD,N]07080 A DISCONNECT -1. ,. ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND w. AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 1 AC DISCONNECT COMPLETE VOLTAGE AND w ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR CURRENT VALUES ON ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A POWER •THIS • DISCONNECT LABEL LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. ALSO • • SOLARGENERATION DISCONNECTOL_AC SYSTEM FOR SOLAR CUSTOMER INFORMATION O 1 PV METER 1 AT PV METER SOCKET AND =_. I�`- THOMAS MURRAY-MS101318 SOCKET ONE DIRECTORY PLACARD 20075 MAIN RD ORIENT, NY 11957 AWARNING 6313233864 O 1 UTILITY METER 1URISTICTION:SUFFOLK DUAL POWER SOURCE SECOND SOURCE IS 1 AT UTILITY METER AND ONE �.,>�,r UTILITY: PSEGLI PHOTOVOLTAIC SYSTEM DIRECTORY PLACARD �== -•- UTILITY ACCT#: '1RW - UTILITY METER#: SOLAR PV SYSTEM EQUIPPED AWARNING-WITH RAPID SHUTDOWN TURN STDDwNPV SYSTEM 1 INTERCONNECTION SwrtCNCN T THUO THDUAL POWER SOURCE POINT I N FO R MATIO N POSRNJN TO SHuTDOUTDOYM PV SYSTEU AND REDOCE SECOND SOURCE IS SHOCK HAZARD IN ARRAY PHOTOVOLTAIC SYSTEM SYSTEM SIZE(DC): 10.8 KW _ SYSTEM SIZE(AC):7.83 KVA © 1 OF EACH AT BUILDING 27 MODULES: HANWHA Q.PEAK DUO BLK INTERCONNECTION POINT ANDML-G10+400 WARNING:INVERTER OUTPUT CONNECTION ONE DIRECTORY PLACARD SAFE HARBOR MODULES:0) DO NOT RELOCATE THIS 1 BACKFEED PANEL 7 INVERTERS: ENPHASE IQ7PLUS-72-2-US OVERCURRENT DEVICE PROJECT INFORMATION INITIAL DATE:6/2/2022 DESIGNER:MA NOMINALOPERATING AC VOLTAGE: •0NOMINAL OPERATING AC FREQUENCY:60HZ REV: DATE: DESIGNER: MAXIMUM O •• '• GI ......i..H ' REV: DATE: DESIGNER: MAXIMUM AC CURRENT: A • • 1 AC CURRENT PV • • MODULE PROTECTION:20 MODULES EQUIPMENT LABELS © BACKFEED PV-4 RT- 1 * EX The standard for rail-less PV mounting Installation Item & Part Number The most advanced Rail-less & Self-flashing PV Mounting System Install Base and End clamp Slide In Mounting RT-APEX Base(RT3-00-AX13K) - w RT-Apex Base;24 ea. S135-60 Screws;48 ea. y — Additonal RT-Butyl ; 12 ea. y•- = i Middle damp Middle Clamp(RT3-02-UM-BK) Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) ., Middle damp; 12 ea. a End Clamp(RT3-02-UE-BK) RT- � End Floating Splice(RT3-02-UEFSBK) End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp X � End Camp; 12 ea. RT-APEX Skirt(RT3-03-SK80BL) Universal Clamping / Slide In Mounting One Step Leveling / Integrated Flexible Flashing One step leveling RT-Apex Skirt 80inch;8 ea. / Proven PV mounting since 1994 3 (108mm) Material Description (75mm) Base I ICC Clams Anodized aluminum ��� Skirt c us r•aa G G Hardware Stainless steel ICC ESR 3575 Intertek Flexible Flashing RT Butyl(ICC ESR 3575) 25 Year Limited Warranty i1/2" (90mm) PAT PENDING . • • _A Roof Tech ch Inc. The Standard for Waterproof Flexible Flashing Since 1994 •• • roof-tech.us www.roof-tech.us info@ roof-tech.us 10620 Treena St. Suite 230, San Diego, CA 92131 • •1 •4 ` Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-us IQ7PLUS-72-2-US Region:AMERICAS ---- —- ------- - --. ---- — -- Commonly used module pairings' 235W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15 A Enphase The high-powered smart grid-ready Overvoltage class DC port II II Enphase IQ 7 Micro-and Enphase IQ 7+Micro' DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array.No additional DC side protection required, Q7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208V/ IQ 7+Microinverters integrate with the Enphase 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy-,Enphase IQ Battery'",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 60 Enlighten'"monitoring and analysis software. Extended frequency range 47-6 68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading 0.85 lagging 0.85 leading 0.85 lagging warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 w 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA - Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38 lbs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes Pollution degree PD3 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication Power Line Communication(PLC) Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options Both options require installation of an Enphase IQ Envoy. UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21(UL 1741-SA) Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO 1071-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) The IQ 7+Micro is required to support 72-cell modules. U� 1 No enforced DC/AC ratio.See the compatibility calculator at hupr/_ /enohase com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. E N P H A S E To learn more about Enphase offerings,visit enphase.com E N P H A S E To learn more about Enphase offerings,visit enphase.COm `J J 2019 Enphase Energy.All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2019326 powered by t MECHANICAL SPECIFICATION DUO © Format 74.0inx41.1Inx1.26in(Indiogtrame) du (1879mm x 1045mm x 32mm) _ __.___..__.. wr aare,.r urnw•..w Weight 48.5lbs(22.0kp) Front Cover 0.13,,(3.2 mm)thermally pre-stressed glass with 4 p160inry :wr anti-rellection technology Back Cover Composite film ,•r ,�,� Frame Bleck anodaed aluminum Cell 6 x 22 monocrystalline Q.ANTUM solar half calls C3 Junction Box 2.094.98inx 1.26-2.36inx 0.59-0.71in (53-101mmx 32-60mmx15-18mm),IP67,with bypass diodes Cable 4mm2 Solar cabi(+)z49.2in(1250mm),(-)z49.2in(1250 mm) •.o.�,.�. Connector Sth"MC4;IP68 -�f-..x in..n nava•a.•*�fr . • , ELECTRICAL CHARACTERISTICS POY CLAN 388 380 388 400 408 • 4 , MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC"(POWER TOLERANCE+5 W/-0W) Power at MPP' Pre. lW[ 385 390 395 400 405 0 E Short Circuit Current' lac [A) 11.04 1107 11.10 11.14 _ 11.17 0. YRE Open Circuit Voltage' Voc IVI 45.19 45.23 45.27 45.30 45.34 ® C2 c Current at MPP I_ JAI 10.59 10.65 10.71 10.77 ..10.83 TOP BRAND PV / ' Voltage at MPP V_ IV] 38.36 36.82 36.88 37.13 3739 ' Efficiency' 4 (%j z19.6 119.9 x20.1 z20.4 x20.6 \ 2021 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Warranty OCn" Power at MPP Pre. [W] 288.8 292.6 296.3 300.1 303.8 wad s.,curlty E Short Circuit Current Iso (A] 8.90 8.92 8.95 8.97 9.00 Open Circuit Voltage V. [V] 42.62 42.65 42.89 42.72 42.78 �f1 3REAKI NG THE 20%EFFICIENCY BARRIER E Current at MPP I_ [A) 8.35 8.41 8.46 8.51 8.57 nl i!I Q.ANTUM DUO Z Technology with baro gap cell layout Voltage at MPP V_ M 34.59 34.81 35.03 35.26 35.46 ��luullWl boosts module efficiency up to 20.9%. 'Mewume nttderwcesP„Poi3%;Iu.Va15%at STCl000W/m',25x2'C,AM15wcwdngtolEC60904-3.2800W/m',NMOT,specur AM15 O CELLS PERFORMANCE WARRANTY PEIIFORMANCE AT LOW MRADIANCE THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY �x'� _•� At least 98%of nominal power during =� -----r-----r -- Q CELLS is the first solar module manufacturer to ass the most com ehen- 3 a -^'�^s 4' g P W _. w firstyear Thereaftermax 05% u r , z ' Q sive quality programme in the industry:The new"Quality Controlled PV'of °g degradation per year At least 93 5% W ' of nominal power up to 10 years.At the independent certification institute TUV Rheinland. > least 86%of nominal power up to f ----------- 25 yeah. ' s°z INNOVATIVE ALL-WEATHER TECHNOLOGY ° _ 4 AN data wrtnrn measurement tderanc- � .; Optimal yields,whatever the weather with excellent '� as Full warranties in accordance with the warranty terms of the O CELLS w r nano w w �-J low-light and temperature behavior. o salesorgan,senonofyourrespectve u . country. R. w.....+d.......,.ro«m•... mans Typical module performance under low irradiance conditions In ENDURING HIGH PERFORMANCE ' comparison to STC conditions(250C,1000W/mi [v 1 Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENT/ o v Techralogy',Hot-Spot Protect and Traceable Quality Tra.QTM. - 0 r<inper„l ure Cunl Lcient of l« a [%/K] +0.04 Temperature Coefficient of V,, / [%/K] -0.27 EXTREME WEATHER RATING Temperature Coefficient of P,,,, If [%/K] -0.34 Nominal Module Operating Temperature NMOT ['FI 109i5.4(43i3'C) High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN high snow(5400 Pa)and wind bads(4000 Pa). Maximum System Voltage V,,; (VI 1000(IEC)/1000(UW PV module classification Claes II 3d O Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 A RELIABLE INVESTMENT ------ (1_.a..�� Inclusive 25-year product warrant and 25-year Max.Design Load,Push/Pull' (lbs/ft2l 75(3600Pa)/55(266OPe) Permitted Module Temperature -40'F upt0+185'F •)\-4 y y y --------- e Z Max.Teat Load,Push/Pull' (lbs/fY) 113(5400Pa)/84(4000 Pe) on Continuous Duty (-40'C up to+851C) linear performance warranty. 'SwMtstMetlonMa�al APT test conditionrew ffurther information. according to info/TS 62804-1.2015,method A(-1500 V,96h) Sae date Sheet on rear fQUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ' UL a1730,CE-cen,plwx. ti9•Ib COr,aue•u PV-TW Rn•ir/rq, � IEC 61215:2016,IEC 917302019, THE IDEAL SOLUTION FOR: US Pei No 9,893,216(soler coW. C E n•...:r Horizontal 76.4in 43.3in 48.Oin 1656Ru 24 24 32 oCPvicerslKewovn9oia9. .94 . packaging 1940mm 1100mm 1220mm 751kg pellets pallets modules Rooftop arrays on - ,num a mrmr residential buildings Note:Installation instructions nvm be followed.See the installation and operating manual Or contact our technical service department for further Information on approved installation and use of this product OCELLS 4e 0 CRL3werle Aa Me. Engineered in Germany 40000 Spectrum Center Drive,Suite 1400.Irvine.CA 92819.USA I TEL+1949 748 59961`EMAIL inquky0us.q-cela.com I WEB www.q-cells us Mina Makar Engineer-PE Mina Makar Engineer-PE Pro Custom Solar LLC 732-902-6224 Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd June 1,2022 3096B Hamilton Blvd June 1,2022 South Plainfield,NJ 07080 South Plainfield,NJ 07080 Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria Thomas Murray Structural Design Loads per ASCE 7-16 APPROVED AS NOTED 20075 MAIN RD ORIENT,NY 11957 Dead Loads=10 psf+2.6 psf(new solar panels)= 12.6 psf DATE-,A a a,B.P. # L4vQ C)9 Roof Live Load=20 psf $ Dear Plan Reviewer: Ground Snow Load/Live Load=30 psf FEE �� 06 B Y Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project NOTIFY BUILDING DEPARTMENT AT and I certify that the products are capable of supporting the code required loads and are suitable for this installation Wind Load Calculation Criteria 765-1802 8 AM TO 4 PM FOR THE when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-16,Ch.30.4 FOLLOWING INSPECTIONS: Regarding the solar panel array installation on the above referenced project please note that an inspection was Design wind pressure determined by Eq.29.4-7: 1. FOUNDATION -TWO REQUIRED performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was Zone I=-40 psf Roof Slope=23 degrees Roof Mean Height-15 ft FOR POURED CONCRETE conducted.There is adequate structural capacity for the installation of the array with the following recommendations: Zone 2=-51.9 psf Basic Wind Speed=120 mph 2. ROUGH-FRAMING.PLUMBING, 1.The array will be installed on the existing roof.The roof framing 3=-59.9 psf Exposure=C STRAPPING, ELECTRICAL&CAULKINGarcing is constructed of 2"x8"wood rafters @16"o.c. 3. INSULATION spanning 8'4"with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf.overall to the roof.The existing structure is sufficient to support the new loads associated with the additional weight&wind + Per section 2.4.1,ASD combo=D+0.6W: 4. FINAL-CONSTRUCTION$ELECTRICAL resistance.No additional structural support is required for the roof structure. Zone 1=2.6 psf+0.6(40 psf)=-21.4 psf MUST BE COMPLETE FOR C.O. Zone 2=2.6 psf+0.6(-51.9 psf)=-28.5 psf ALL CONSTRUCTION SHALL MEET THE 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed Zone 3=2.6 psf+0.6(-59.9 psf)=-33.3 psf REQUIREMENTS OF THE CC E:S OF NEW instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between YORK STATE NOI RESPOV - F FOR dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as Check Attachment to Wood Rafter DESIGN OR CONSTRUCTION ERRORS specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter summary table below: Lag Screw Spacing: Lag Screw Tributary Area: ♦�� Roof T /ILL Shingle Fastener Max Spacing(in.) Zone I= 48"o.c.max Zone 1=(48"o.c.max)^2/144=16 SF CONST�RUCTM SKkL Attachment System: "ROOFMCH"®RT-APEX Wind Zone 1 Wind Zone 2 Wind Zone 3 Zone 2= 32"o.c.max Zone 2=(32"o.c.max)^2/144=7.11 SF MEET THE REVUIRE1�i1��S OF TNE Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 32 32 Zone 3= 32"o.c.max Zone 3=(32"O.C.max)^2/144=7.11 SF COM OF itv�X YM M embedment of 3"into the rafters WVW Y► �wi A[G 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. Lag Screw Forces: W=2661b/in(Table 12.2A,2015 NDS) 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Zone 1=21.4 psf x 16 SF=342 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) G J CO ntnpC� m U51 5.All aspects of the installation shall comply with the 2020 Residential Code of New York State,ASCE-7-16,2017 Zone 2=28.5 psf x 7.11 SF=203 lb < W', OK Ct=1(Table 2.3.3,2015 NDS) �l� T National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 3=33.3 psf x 7.11 SF=237 lb < W, OK W'=W x embed x Cd x Ct D['G` "Cel. O W-51de Ctbe lee law. W=266 lb/in x 3 in.x1.6 x 1=1276.8 lb e r{o-dy a cce ss i lole, . 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. ELECTRICAL INSPECTION REO(M90 Of NEW,, f. COMPLY Wr M ALL CODES OF NEW YORK STATE &TOWN CODES dW -d AS REQW D AND CONDITIONS OF Mina Makar,P.E. c> W NY.Lic.No.104468 � 2 s�oA 104468 R�FESSIONP�" SOUTHOLD TOWN RAM l 2 � DDn IC Iln � II SOUTHOLD TOWN TRUSTEM D N.Y.S.DEC JUN 1 902 BUILDING DEPT TOWN OF SOUTHOLD PLAN KEY SYSTEM INFORMATION THE RESPONSIBLE LICENSED DESIGN PROFESSIONAL SHALL PV-1 COVER PAGE MODULE HANWHA Q.PEAK DUO BLK ML-G10+ 400 PROVIDE A SIGNED AND SEALED LETTER CERTIFYING THE PV-1(2) COVER PAGE CONT. INVERTER ENPHASE IQ7PLUS-72-2-US INSTALLATION WAS INSPECTED AND CONFORMS TO THE momentum PV-2 PANEL LAYOUTPLANS AND REQUIREMENTS OF THE 2020 NYS BUILDING RACKING ROOFTECH RT-APEX CODE AND 2020 NYS RESIDENTIAL CODE. THIS INSPECTION SOLAR PV-3 ELECTRICAL AND CERTIFICATION LETTER SHALL BE PERFORMED AFTER SYSTEM SIZE (DC) 8 KW INSTALLATIONS ARE COMPLETED AND SHALL BE SUBMITTED PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-4 EQUIPMENT LABELS TO THE BUILDING DEPARTMENT PRIOR TO SCHEDULING OF 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ LOCATION 41.1438098,-72.3117572 FINAL INSPECTION. (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING THE UL CERTIFICATE OF ELECTRICAL INSPECTIONS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO �OF NEW GENERAL NOTES: SCHEDULING OF FINAL INSPECTION. �'`V\ A• Mqy��P,� THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 2020 NYS BUILDING CODE AND 2020 NYS RESIDENTIAL CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. C7 AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ON BOTH SIDES OF Z THE ROOF. NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM ��`O 104468 LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36 INCHES (914 MM) WIDE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE p��FESSIONP�' PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES WIDE (914 MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME MINA A.MAKAR, 224 30968 HAMILTON BLVDSOUTH PLAINFIELD,N)07080 ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND TION SPANS STRADDLING THE SAME AND ADJACENT ROOF PLANES. AT°ACHHMENTS To EEOT LOCAL AND STATE BUNS FOR SOLAR ILDING CODE � COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. BILL OF MATERIALS CUSTOMER INFORMATION WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR MODULES 20 THOMAS MURRAY-MS101318 PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER INVERTERS 20 SYSTEMS. 20075 MAIN RD ROOFTECH BASE 67 ORIENT, NY 11957 ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT 6313233864 INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VE-.NT REQUIRES A MID CLAMP 31 1URISTICTION:SUFFOLK PLUMBING PERMIT AND INSPECTION. END CLAMP 31 UTILITY: PSEGLI UTILITY ACCT#: INVERTER PLACEMENT: END SPLICE 5 UTILITY METER#: END FLOATING SPLICE 5 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. MID FLOATING SPLICE 10 PV SYSTEM BUILDING REVIEW NOTE: SKIRTS 9 INFORMATION ENPHASE COMBINER BOX 1 SYSTEM SIZE (DC):8 KW TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR SOLAR AC DISCONNECT 1 SYSTEM SIZE(AC):5.8 KVA MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED 20 MODULES: HANWHA Q.PEAK DUO BLK IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. 40A OCPD 1ML-G10+400 THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE:. THATSAFE HARBOR MODULES:0) RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW 125A LINE TAPS 2 0 INVERTERS: ENPHASE IQ7PLUS-72-2-US YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S PR03ECT INFORMATION BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: INITIAL DATE:6/2/2022 DESIGNER:MA 1. ACCURATE REV: DATE: DESIGNER: 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE REV: DATE: DESIGNER: SUBMISSION. 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO COVER PAGE THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. PV- 1 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP ROOFS RT- RT-APEX CONSIDERED FROM AN ANGLE OF MIN.9.5° (J)TO MAX.45- (12)NOT TO EXCEED The ..stanr. . momentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE PEX MANUFACTURER. advancedThe most Installation Item&Part Number SOLA R 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE Install Base and EnO drrV 9Yd•In Motx•IFq RTr1PEx aua(RT3 OO A%BK) MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE �` _ / PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR MANUFACTURER. /'" 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 RT-Ape.Base 24 ea (732)902-6224,MOMENTUMSOLAR.COM 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH pr _ Asa onaoRreBuyl;12. PROFESSIONAL ENGINEERING la7 Middle clamp-- amp MANUFACTURERS PRINTED INSTRUCTIONS. ^,' Mddle Clamp(RT3.0$4JM.•K) Middle Fkreung Splice(RT3-02-UMFSBNI M.1dleClampSO—(RT3-02-UMSBK) NEW y Middle camp.12 ea EM Cbmp IRT3-02 UE BKI 1 EM Fwaorq Sprrl(RT3-02-VEFSBK) RTEnd CWmp Splice(RT3D2 UESBKI Skirt and End Splice Skirt and End damp ^ r 2 � PEX Clamp, End 12 ea. ` '_ RT-APEX Skirt(147103-9K808L) Universal Clamping / Slide In Mounting �(��A 104468 One Step Leveling / Integrated Flexible Flashing One step leveling ! SSIONP�' RT-Apex Skin 80irch 8 ea Proven PV mounting since 1994 3• (;Damm) ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS (��^t^1 MINA .MAKAR,P.E.NY LI « 44 8 7 - 4 p�. Camp. Anodised aluminum 30968 HAMILTON SLVDSOUTH PLAINFIELD,NJ 07080 AS PER ASCE 07-16. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C, &D AND ROOF ICC c7� Ci'►°p� Hard Stai 1e3fstee1-- ENG NEER LETTER ATTACHED HAS SPECIFICATIONS FOR WIND WIND ZONES 1,2,&3. ROOF ZONES 2& 3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, -'•' CC Esa: '� fkdaef asrdgAr twiv(i«Esp 3575) AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS Inttrtek FI-W --- - ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE RIDGE, OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. �-._--- 25 Year Limited Warnntr COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 3 Ur 90mm PAT PENOINC, ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. A Roof Tech Roof Tech Inc. GUTTER GUTTER " 0. •Treena St.Suite 230,San Diego, 858.935.6064 Y 9('3) CUSTOMER INFORMATION � ® O Q� THOMAS MURRAY-MS101318 (D 20075© ® RIDGE RIDGE 02) © ® ® ©® ORIEENT, NA1119D57 'S6313233864 Y JURISTICTION:SUFFOLK < ® © UTILITY: PSEGLI UTILITY ACCT#: © ® GUTTER ® GUTTER UTILITY METER#: STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEry PV SYSTEM ROOF ZONES 2&3 ARE 48"FROM CUTTER ROOF EDGES, INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES, AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-JOIST SPANS. SYSTEM SIZE (DC): 8 KW SYSTEM SIZE(AC): 5.8 KVA TABLE R301.2(1) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW 0 MODULES: HANWHA Q.PEAK DUO BLK YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERI AL-G10+400 GROUND SNOW LOAD(LBS/SF) 2S OF THE TOWN. SAFE HARBOR MODULES:0) SPEED (MPH) 130 2O INVERTERS: ENPHASE IQ7PLUS-72-2-US TOPOGRAPHIC EFFECTS B PROJECT INFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 837 LBS SPECIAL WIND REGION NO INITIAL DATE:6/2/2022 DESIGNER:MA TOTAL NUMBER OF ATTACHMENT POINTS 62 WIND BORNE DEBRIS ZONE 2 REV: DATE: DESIGNER: EIGHT PER ATTACHMENT POINT 13.5 LBS SEISMIC DESIGN CATEGORY C HANWHA Q.PEAK DUO BILK ML-G10+ 400 REV: DATE: DESIGNER: 400 WATT MODULE TOTAL SURFACE AREA OF PV MODULES 362.8 SQFT CLIMATE ZONE 4A 7411 X 41.111 X 1.26" COVER PAGE (SEE DATASHEET DISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT WIND EXPOSURE CATEGORY B PVA 1 ( 2) LANDSCAPE SCALE' 1�16" = V-101" ROOF MODULE COUNT TILT AZIMUTH SHADING XN PORTRAIT ROOF AREA 12 3 ROOF AREA 1 2P3N • R1 14 20° 171° 80% 72/72/71 44/44 42 R2 6 20° 351° 81% 72/72/71 44/44/42 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING NEw y GROUND ACCESS (NP) r � DRIVEWAY FIRE SETBACK W 0'-62" (18" VENTILATION, _ -------- ----------GUTTER 36" ROOF ACCESS) FO 104468 ---- ---- i t (nP) A��FESSIONP� ii R2------- Jj I j 1 j MINA A.MAKA 14 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE -- COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY, CUSTOMER INFORMATION 3'-0" THOMAS MURRAY- MS101318 20075 MAIN RD U ORIENT, NY 11957 w O ATS EXTERIOR 6313233864 o JURISTICTION:SUFFOLK 2 � c6 DAsc sP UTILITY: PSEGLI SYMBOL LEGEND ZQ EXTERIOR INTERIOR O UTILITY ACCT#: O UTILITY METER#: MSP MAIN SERVICE PANEL CHIMNEY F_ ELECTRICAL EQUIPMENT O U_ SP SUB-PANEL z SKYLIGHT PV SYSTEM MO UTILITY METER ® VENT INFORMATION SYSTEM SIZE(DC):8 KW CB AC COMBINER BOX/AC PIPE VENT SYSTEM SIZE(AC): 5.8 KVA DISC DISCONNECT 0 MODULES: HANWHA Q.PEAK DUO BLK L-G 10+400 uoc UTILITY DISCONNECT FAN SAFE HARBOR MODULES:0) 0 INVERTERS: ENPHASE IQ7PLUS-72-2-US LC LOAD CENTER 4 SATELLITE DISH PROJECT INFORMATION N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS INITIAL DATE:6/2/2022 DESIGNER:MA REV: DATE: DESIGNER: CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: LEI F PERFORMANCE METER PITCH DIRECTION PANEL LAYOUT EAMODULE PV-2 20 HANWHA Q.PEAK DUO BLK ML-G10+400 40OW MODULES PAIRED WITH 20 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUIT A 13 MICRO-INVERTERS EXISTING MURRAY 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B UTILITY SUB PANEL 240 V 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N] 7 MICRO-INVERTERS METER (732)902-6224,MOMENTUMSOLAR.COM GRID MAIN BREAKER:200A PROFESSIONAL ENGINEERING +B - +8 - +B - ENPHASE 80AAC f OF NEN/ COMBINER BOX 89L AC DISCONNECT 200A `P�P A• Mqy��,� _ _ = W!ENVOY IQ �\ g LINE SIDE ®-�- HOT TAP T 1 - 1 8 40A 1 200 1 r ROOF 10A/15A BREAKER JUNCTION (MANUFACTURER 40A OCPD =GROUND n SUPPLIED FOR ENVOY) TO POWER vFO 104468 TERMINATION CAP 1 BOX 2A-B (COMMUNICATION) 3 4 GENERATOR INSTALLED ON 20A BREAKER(A)(PV) GENERATOR A��FESSIONP� END OF CABLE 20A BREAKER(B)(PV) TRANSFER SWITCH MINA A.MAKAR,P.E.NY LICENSE# 0446 (732)-902-6224 3096B HAMILTON BLVDSOUTH PLAINFIELD,N)07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOUR DBA MOMENTUM SOLAR 902-6224 ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 3096 HAMILTON BLVVD.732)BUILDING B,SOUTH PLAINFIELD,N307080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER INFORMATION PARAGRAPH Q. THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. THOMAS MURRAY- MS101318 BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS 20075 MAIN RD DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6, 690.17. ORIENT, NY 11957 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH 6313233864 89L LESS THAN 10FT TO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM INFORMATION SYSTEM SIZE(DC):8 KW SYSTEM SIZE(AC):5.8 KVA Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 0 MODULES: HANWHA Q.PEAK DUO BLK Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current (A) Size Type L-G10+400 SAFE HARBOR MODULES:0) 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable 20 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2A 3/4" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 PR03ECT INFORMATION 26 3/4" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 7 1.21 1.25 10.59 08 AWG THWN-2 INITIAL DATE:6/2/2022 DESIGNER:MA REV: DATE: DESIGNER: 3 3/4" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 20 1.21 1.25 30.25 08 AWG THWN-2 REV: DATE: DESIGNER: 4 3/4" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 20 1.21 1.25 30.25 08 AWG THWN-2 ELECTRICAL I I I I I 1 -1: PV-3 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY O CAUTION: SOLAR VOLTAGE12 AC CONDUITS ENCLOSURES/WALLS/ PARTITIONS/CEILINGS/FLOORS =-- momentum OR NO MORE THAN 10' - `y 7t- : SOLAR © • 1 COMBINER BOX 1 AT ANY COMBINER BOX PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N) (732)902-6224,MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING AWARNT" of NEW © ELECTRICAL SHOCK HAZARD Gj ��P• A k4,�q .� TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX © 'P LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LAJ s r � PV SYSTEM AC • 0,21 AWARNING RATED SF O ,oa4ss OUTPUT o ELECTRICAL SHOCK HAZARD NOMINALOPERATINGTERMINALS ON BOTH LINE AND AC ESSIO VOLTAGELOAD SIDES MAY BE ENERGIZED �y IN THE OPEN POSITION h a MINA A.MAKAR, LICENSE#104468 - 0 - 4 A CAUTION 1 OF EACH AT FUSED AC I 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 DISCONNECT •- ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 1 AC DISCONNECT COMPLETE VOLTAGE AND ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE CURRENT VALUES ON COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A POWER • DISCONNECT LABEL LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY. •SUPPLIED FROM ON-SITE SOLAR • - • SHUTDOWN O O .NNECT •- SOLAR L AC SYSTEM DISCCUSTOMER INFORMATION 1 PV METER 1 AT PV METER SOCKET AND THOMAS MURRAY-MS101318 SOCKET ONE DIRECTORY PLACARD 20075 MAIN RD AWARNING ORIENT, NY 11957 631323386464 O 1 UTILITY METER 1URISTICTION:SUFFOLK DUAL POWER SOURCE 1 AT UTILITY METER AND ONE no.:o::. ':.s„s,en UTILITY: PSEGLI SECOND SOURCE IS o _. DIRECTORY PLACARD UTILITY ACCT#: PHOTOVOLTAIC SYSTEM 0'°!;al' - UTILITY METER#: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7Z'WARNI'NG PV SYSTEM TURN RAPID SHUTDOWN 1 INTERCONNECTION SWITCH TO HUTDO DUAL POWER SOURCE POINT S = POSITION TO SHUTDOWN INFORMATION PV SYSTEM AND REDUCE SECOND SOURCE IS O SNOCR HAZARD IN ARRAY PHOTOVOLTAIC SYSTEM SYSTEM SIZE(DC): 8 KW © SYSTEM SIZE(AC):5.8 KVA 1 OF EACH AT BUILDING 20 MODULES: HANWHA Q.PEAK DUO BILK INTERCONNECTION POINT AND M L-G 10+400 LDO NVERTER OUTPUT CONNECTION ONE DIRECTORY PLACARC SAFE HARBOR MODULES:0) NOT RELOCATE THIS BACKFEED PANEL 0 INVERTERS: ENPHASE IQ7PLUS-72-2-US VERCURRENT DEVICE PROJECT INFORMATION INITIAL DATE:6/2/2022 DESIGNER:MA OPOFFING AC VOLlV4MVWWW— _ • I MAXIMUMHZ MINAL .OPERATING _EQUENCY: �, REV: DATE: DESIGNER: OAC • REV: DATE: DESIGNER: -URRENT: A 1 AC CURRENT PV AC PROTECTION: MODULES EQUIPMENT LABELS MODULE © BACKFEED PV-4 RT-APEX The APEX • . • for rail-less PV mounting Installation Item & Part Number The most advanced Rail-less & Self-flashing PV Mounting System Install Base and End clamp Slide In Mounting RT-APEX Base(RT3-00-AXBK) RT-Apex Base ; 24 ea. _ SD5-60 Screws ; 48 ea. Additonal RT-Butyl ; 12 ea. Middle clamp Middle Clamp(RT3-02-UM-BK) Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) f' y.y , y Middle clamp; 12 ea. - Y4 '��Y'S•'6'.qtr_xl?fF 1:.'F.;L.".9 t�..M.-'... End Clamp(RT3-02-UE-BK) RT_ End Floating Splice(RT3-02-UEFSBK) End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp ,- End Clamp; 12 ea. RT-APEX Skirt(RT3-03-SK80BL) Universal Clamping / Slide In Mounting - One Step Leveling / Integrated Flexible Flashing One step leveling ! RT-Apex Skirt 80inch ; 8 ea. Proven PV mounting since 1994 4 1/4" 3„ (108mm) Material Des cri tion (75mm) Base ICC Clamps Anodized aluminum Skirt � Amo ��,■ G Hardware Stainless steel ICC ESR 3575 Intertek Flexible Flashing RT Butyl(ICC ESR 3575) 25 Year Limited Warranty 3 1/2" (90mm) PAT PENDING Roof Tech Roof Tech Inc. The Standard for Waterproof Flexible •• • • '•• 10620 1 Diego, 92131 www.r858.935.6064 ` Enphase IQ 7 and IQ 7+ Microinverters Enphase frlicn:invarters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Enphase The high-powered smart grid-ready Overvoltage class DC port 11 11 ,, Enphase IQ 7 Micro and Enphase IQ 7+Micro- DC port backfeed current 0 A 0 A" Q 7 a n d I Q 7 y simplify PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; ♦ dramaticall sim li the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters - - ----- ---______25_0 _ - Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208V/ 240 V/ 208V/ 9 P 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy-,Enphase IQ Battery',and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Enlighten-monitoring and analysis software. -6 60-6 Extended frequency range 47 68 Hz 47 68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuity 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port 111 111 undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 56 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40*C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38 lbs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes Pollution degree PD3 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication Power Line Communication(PLC) Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 4l disconnect required by NEC 690. h Smart Grid Read Compliance CA Rule 21(UL 1741-SA) r - y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) U 'The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httpa,//enohase.com/en-us/support/module-comp tia bility. ` 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com �/ EN PHAS E To learn more about Enphase offerings,visit enphase.com EN PHAS E. J 2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2019.3-26 Pointered M MECHANICAL SPECIFICATION ov !t U Q 74.0 in x 41.1 in x 1.26 in(including frame) (1879mm x 1045mm x 32mm) 48.5lbs(22.01,g) 0.13in(3.2mm)thermally pre-stressegk dss with } + anti-reflection technology - - I�~ Composite film s.raw�l Black anodized aluminum 6 x 22 monocrystalline Q.ANTUM solar hall cells O urpo«,n. 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm).IP67,with bypass diodes =w r 4mm2 Solar cable.(,)z49.2in(1250mm),(-)a49.2in(1250mm) •°ar".wn°I. ._......................... -_.... -........ + t.Nww.,NNptTaL4 i Staubli MC4;IP68 r III ooe mt.-a IflIo>.•n.� . . , ELECTRICAL CHARACTERISTICS POWERCLASS 385 390 395 400 405 V 7-1, F-"'RMAfJCEAT STAMD.SRDTEST -� .S V! Pcwerat MPP' P [WI 385 390 395 400 405 Short Circuit Currr-.nt' Isc [A] 11.04 1107 11.10 11.14 11.17 YR u Open Circuit Voft sqcV c IV] 45.19 4523 45.27 45.30 45.34 •' c Current et MPP [A[ 10.59 1065 1071 10.77 10.83 TOP BRAND PVlee Voltage at MPP - V,,,, (V) 36.36 3662 36.88 3713 3239_ ' Effrawncy 9 [%[ >_19.6 >_19.9 >_20.1 >_20.4 220.6 2 2 MINIMUM PERFORMANCE AT NORMAL OPERA"1 Warranty QCELLS Power at MPP P„,e [W] 288.8 292.6 296.3 3001 303.8 Y.Ad Sacur,tY - -._... .__ E Short Circuit Currant Isc (A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage V. IV] 42.62 42.65 42.69 42.72 42.76 E ._ _....�.. BREAKING THE 20%EFFICIENCY BARRIER f Current at MPP 11.11 [A] 8.35 8.41 8.46 8.51 8.57 Q.ANTUM DUO Z Technology with zero gap cell layout vu,° [V] 3459 34.81 3503 3525 35.46- bOOstsmodUleefflCiencyupt020.9%. Measurement tolerances P,,,33%.Is,:.V:.,z5%at STC 1000W/m2.25m2aC.AM 15 according to IEC 60904-3.'800W/,,2,NMOT,spectrum AM 15 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY " _oma« At least 98%of nominal power during T-_---r r , - Q CELLS is the first solar module manufacturer to pass the most comprehen- first year.Thereafter max.0.5% + I Q sive quality programme in the industry:The new"Quality Controlled PV*of ----------------------------- degradation per yearpower least 93 5% .. --- v r of nominal power up to 10 yeah.At the independent certification institute TUV Rheinland. least 86%or nominal oweru9to + I I I + " -.-.. _ _______ 25 years. '°---r­----------------4------u i INNOVATIVE ALL-WEATHER TECHNOLOGY All data-thin measurement tolerant- q �•a�� " ----- ------------------ es.Full warranties in accordance with ffi Cmc Optimal yields,whatever the weather with excellent the warranty terms of the 0 CELLS low-light and temperature behavior. sales organisation of your respective 0 u " . country. " Typical nodule performance under low irradiance conditions in ENDURING lPERFORMANCE ,. ^ comparison to STC conditions(254C,1000 W/ms) Long-term yield securitywith Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS Technology',Hot-Spot Protectd Traceable alit Tra.Q md Temperature Coefficient of l a [%/K] +0.04 Temperature Coefficient of V„c 0 [%/KI -027 Temperature Coefficient of P.,,, y [%/K] -0.34 Nomi V,i i3O .:,,,i Temperature NMOT [°F] 109154(43±3°C) " EXTREME WEATHER RATING _. _ -__-- a High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN high snow(5400 Pa)and wind loads(4000 Pa). Maximum System Voltage V. IV] 1000(1 EC)/1000(UL) Class 11 Q Maximum Series Fuse Rating [A DC[ 20 Firs,Rating based on ANSI/UL 61730 TYPE 2 A RELIABLE INVESTMENT - ----- - ---- Max.DesignLoad.Push/Pu1P [lbs/W] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F o �....�/f Inclusive performance product warranty and 25-year _- on Continuous Duty (-40'C up to+85*C) o ��l„[�( linear performance warranty'. Max-Test!.oad.Push/Puu' [lbs/ft'] 113(5400 Pa)/84(4000Pa) ,See Installation Manuel -.._ _._.__.._...._... 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V.96h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION 'See data sheet on rear for further information. UL auxily 0,CE-c0.rrPV-T N11 Ib M=0- 1 $ 1. ,,106.EC 61730 20.irirM- [� L�`llaa////JJ �I O-O ibhe IEC 811152016.IEC 81730'2018. e .._..... ...._ THE IDEAL SOLUTION FOR: is Fel."No9.993.21a(,Awcots). SP® C E or m,l 76.4 in 43.3in 48.0in 16561bs 24 24 32 oCPV cornfloeaon ongo,,v C 0Us ,vy�° packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules z revdentral buddmgs avn Noto:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product OCELLS 400SpeGCBLLSAmadoa Suit Engineered in Germany 400 Spectrum Center Drive Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 961 EMAIL Inqu,ry@us it-cells tom I WEB wwwq-cells.us