Permit#: 48464 Date: 11/9/2022
Permission is hereby granted to:
Corcoran EP 20yr FI APRT
30 Fifth Ave #4D
New York,IT.... .1..... .... .................. . .....
NY 0011
To: Construct additions and alterations to an existing single family dwelling as applied for.
At premises located at:
Crescent Ave., Fishers Island
SCTM # 473889
Sec/Block/Lot# 6.-2-10
Pursuant to a
pplication dated 8/30........_.._../2022 and approved by the Building Inspector.
To expire on 5/10/2024.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $1,641.60
CERTIFICATE OF OCCUPANCY $50.00
....
Total: $1,691.60
.... ..w...... ..........................
Building Inspector
,!y'N7a
Wit
„� TOWN OF SOUTHOLD—BUILDING DEPARTMENT
" Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
° Telephone (631) 765-1802 Fax (631) 765-9502 17i41 ..P�www. ttltal�ltrwta . ar '
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
y
PERMIT NO. Building Inspector: If
Applications and forms must be filled out in their entirety. Incomplete „HU+H,:Crel 1
applications will not be accepted. Where the Applicant is not the owner,an u i
Owner's Authorization form(Page 2)shall be completed.
Date:8/12/2022
OWNER(S)OF PROPERTY:
Name:EloisePatterson/Rob Walls SCTM#1000-6-2-10
Project Address:45 Avenue B Fishers Island NY 06390
Phone#:631-788-7143 EEII.:Shawn@bdrrusa.com
Mailing Address:PO Box 447 The Gloaming Fishers Island NY 06390
CONTACT PERSON:
Name:Shawn Pierce Bd Remodeling
Mailing Address:PO Box 447 The Gloaming Fishers Island NY 06390
Phone#:631-788-7919 IEail.Shawn@bdrrusa.com
DESIGN PROFESSIONAL INFORMATION:
Name:McBride Architects/ Grant Scott
Mailing Address:37 West 28th Street 11th floor New York ,NY 10001
Phone#:212-941-0818 =Em�il:jgskmcbride-architects.com
CONTRACTOR INFORMATION:
Name:BD Remodeling
Mailing Address:PO Box 447 The Gloaming Fishers Island NY 06390
Phone#:631-788-7919 IE,'-:s:hawn@bdrrusa.com
DESCRIPTION OF PROPOSED CONSTRUCTION
New Structure ❑Addition iRAlteration LJRepair ❑Demolition Estimated Cost of Project:
❑Other Interior renovations new exterior windows and doors $650,000
Will the lot be re-graded? ❑Yes 5iNo Will excess fill be removed from premises? Dyes RNo
1
PROPERTY INFORMATION
Existing use of property:Single family Intended use of property:
single family
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R_80 this property? ❑Yes *— No IF YES, PROVIDE A COPY.
R Check BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law.
Application Submitted By(print n e): �� ,-� Authorized Agent ❑Owner
Signature of Applicant: Date: l
STATE OF NEW YORK)
SS�Sh:
1�C
COUNTY OF Tadwo )
(- -. being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
I
(S)he is the CL4 i42Lka�
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
/���j ....... syM#*111/1//�Ir
L r yAd Z-1
as
�- .�
AL, ..7
PROPERTY AUTHORIZATION � 0
(Where the applicant is not the owner)
N, residing at � f
do hereby authorize to apply on
my behalf to t Tow Southold Building Department for approval as described herein.
t;s Signature Date
r) r
Print Owner's Name
2
Generated by REScheck-Web Software
Compliance Certificate
Project Patterson Walls House
Energy Code: 2018 IECC
Location: Southold, New York
Construction Type: Single-family
Project Type: Alteration
Orientation: Bldg. faces 90 deg. from North
Climate Zone: 4 (5572 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
45 Avenue B Eloise Corcoran Grant Scott
Fishers Island, NY 06390 45 Avenue B McBride Architects
Fishers Island, NY 06390 37 W28th St
11th Floor
New York, NY 10001
617 9096603
jgs@mcbride-architects.com
Slab-oin girade tradeoffs acre no Iloirkger coinsudeired in the 9..YA oir performance cos 1pIlliairu::e IryatV"ti In RESclheck. Each sllald on-grade
asseirnlrnlly ilin tlhie specutued clllimate Zone must meet the r1lMirnuirn ermergy code insu lladon IIS-value and depth reguliueimmernts.
Envelope Asset"R"flblme
Prop.Gross Area Cavity Cont. III Prop.
Perimeter
Dining: Flat Ceiling or Scissor Truss 306 40.2 10.5 0.022 0.026 7 8
Pantry and Laundry: Flat Ceiling or Scissor Truss 136 49.0 0.0 0.026 0.026 4 4
Powder and Closet: Flat Ceiling or Scissor Truss 61 49.0 0.0 0.026 0.026 2 2
WIC: Flat Ceiling or Scissor Truss 51 49.0 0.0 0.026 0.026 1 1
Bedroom Wing: Cathedral Ceiling 957 49.0 0.0 0.022 0.026 20 24
Skylight 1:Wood Frame:Double Pane with Low-E 14 0.430 0.550 6 8
SHGC: 0.22
Skylight 2:Wood Frame:Double Pane with Low-E 8 0.430 0.550 3 4
SHGC: 0.22
Skylight 3:Wood Frame:Double Pane with Low-E 8 0.430 0.550 3 4
SHGC: 0.22
Living Wing:Cathedral Ceiling 710 49.0 0.0 0.022 0.026 15 17
Skylight 4:Wood Frame:Double Pane with Low-E 38 0.430 0.550 16 21
SHGC: 0.22
TV and Bath 2: Cathedral Ceiling 186 49.0 0.0 0.022 0.026 4 5
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 1 ofll
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Perimeter
North Facing Gross: Wood Frame, 16" o.c. 722 25.9 0.0 0.052 0.060 13 15
Orientation: Right side
LR window:Wood Frame:Double Pane with Low-E
SHGC: 0.36 35 0.260 0.320 9 11
Orientation: Right side
LR window:Wood Frame:Double Pane with Low-E
SHGC: 0.36 87 0.260 0.320 23 28
Orientation: Right side
LR window:Wood Frame:Double Pane with Low-E
SHGC: 0.36 35 0.260 0.320 9 11
Orientation: Right side
DR window: Wood Frame:Double Pane with Low-E
SHGC: 0.30 138 0.360 0.320 50 44
Orientation: Right side
BR4 window: Wood Frame:Double Pane with Low-E
SHGC: 0.27 40 0.270 0.320 11 13
Orientation: Right side
BR3 window: Wood Frame:Double Pane with Low-E
SHGC: 0.27 40 0.270 0.320 11 13
Orientation: Right side
BR2 window:Wood Frame:Double Pane with Low-E
SHGC: 0.27 40 0.270 0.320 11 13
Orientation: Right side
BR1 window: Wood Frame:Double Pane with Low-E
SHGC: 0.27 62 0.270 0.320 17 20
Orientation: Right side
East Facing Gross: Wood Frame, 16"o.c. 396 25.9 0.0 0.052 0.060 14 17
Orientation: Front
Door 1: Solid 21 0.260 0.320 5 7
Orientation: Front
Window 1: Wood Frame:Double Pane with Low-E
SHGC: 0.31 31 0.260 0.320 8 10
Orientation: Front
Window 2: Wood Frame:Double Pane with Low-E
SHGC: 0.31 51 0.260 0.320 13 16
Orientation: Front
Window 3: Wood Frame:Double Pane with Low-E
SHGC: 0.31 15 0.260 0.320 4 5
Orientation: Front
South Facing Gross: Wood Frame, 16" o.c. 722 25.9 0.0 0.052 0.060 24 27
Orientation: Left side
Window 12:Wood Frame:Double Pane with Low-E
SHGC: 0.36 34 0.260 0.320 9 11
Orientation: Left side
Window 13:Wood Frame:Double Pane with Low-E
SHGC: 0.30 138 0.360 0.320 50 44
Orientation: Left side
Window 14: Wood Frame:Double Pane with Low-E
SHGC: 0.36 31 0.260 0.320 8 10
Orientation: Left side
Window 15:Wood Frame:Double Pane with Low-E
SHGC: 0.36 31 0.260 0.320 8 10
Orientation: Left side
Window 16• Wood Frame:Double Pane with Lo..-E
SHGC: 0.36 31 0.260 0.320 8 10
Orientation: Left side
West Facing:Wood Frame, 16"o.c. 466 25.9 0.0 0.052 0.060 10 12
Orientation: Back
Window 17:Wood Frame:Double Pane with Low-E
SHGC: 0.36 50 0.260 0.320 13 16
Orientation: Back
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 2 of 11
Gross Area Cavity Cont. Prop. Req. Prop. Req,
Perimeter
Window 18: Wood Frame:Double Pane with Low-E
SHGC: 0.36 24 0.260 0.320 6 8
Orientation: Back
Window 19: Wood Frame:Double Pane with Low-E
SHGC: 0.36 21 0.260 0.320 5 7
Orientation: Back
Window 20:Wood Frame:Double Pane with Low-E
SHGC: 0.36 55 0.260 0.320 14 18
Orientation: Back
Window 21: Wood Frame:Double Pane with Low-E
SHGC: 0.36 88 0.260 0.320 23 28
Orientation: Back
Window 22: Wood Frame:Double Pane with Low-E
SHGC: 0.36 30 0.260 0.320 8 10
Orientation: Back
Floor 1:All-Wood Joist/Truss:Over Unconditioned 1,158 0.0 22.2 0.038 0.047 44 54
Space
Floor 2: Slab-On-Grade:Unheated 171 10.0 0.730 0.730 0 0
Insulation depth: 6.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 3 ofll
REScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID _ _ _
L--
103.2do
, :Construction s and
gp Re q uirem drawings � �7- L��� m ❑❑Does Not t...
Requirement will be met.
mentation demonstrate
[PR1]1 energy code compliance for the
'building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ,❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating:-�� Heating.
:❑Complies
403.7 'sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling Cooling ❑Not Observable
'Manual J or other methods Btu/hrBtu/hr
approved by the code official ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 4 ofll
Section flans'Verified Field Verified
Foundation Inspection 'Value "Value Complies? Co ments/ ssumptions
& fte anti
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values.
❑ Heated ❑ Heated ❑Not Observable
❑Not Applicable
402.1.2 Slab edge insulation ft ft ❑Complies see the Envelope Assemblies
[F0311 depth/length. ❑Does Not table for values.
❑Not Observable
❑Not Applicable
012.1 A protective covering is installed flCompllies
[F01112 to protect exposed exterior Zboes Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 ;Snow-and ice-melting system `❑Complies
IF01.212 controls installed. `❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
[11 High Impact(Tiler 1) L2�Medium Impact(Tier 2) 3 Low Impact(Tier 3}
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 5 ofll
Section
Plans Verlue fied Field Verified Complies? Comments/Assumptions
& Re ID
�— ugh-In Inspectioi___
Comp ies.
# Framing /Rough-in
Valu e
....-. _ �...-- ....
402.1.1, Door U-factor. U- U- '❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- j❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
❑
402.5 Not Observable
[FR2]1 ❑Not Applicable
303.1.3 IU-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. [-]Not Observable
❑Not Applicable
402.1.1, Skylight U-factor. U- U- I❑Complies See the Envelope Assemblies
402.3.3, ❑Does Not table for values.
402.3.6,
402.5 ❑Not Observable
[FR5]1 ❑Not Applicable
402.4.1.1 (Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
V11 ❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
❑Not Observable
or has infiltration rates per NFRC .-
:400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
;and labeled to indicate :52.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.3.1 ;Supply and return ducts in attics ❑Complies
[FR12]1 !insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >—AO) ❑Not Observable
R-6 where < 3 inches.Supply and
return ducts in other portions of ❑Not Applicable
:the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.2 Ducts, air handlers and filter .❑Complies
[FR13]1 'boxes are sealed with ❑Does Not
joints/seams compliant with
International Mechanical Code or ❑Not Observable
International Residential Code, as ❑Not Applicable
applicable.
403.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R _..... ... _mw_ R-_ ElComplies
[FR17]2 above 105°F or chilled fluids ❑Does Not
below 55 °F are insulated to >—R
❑Not Observable
3
❑Not Applicable
1 'High Impact(Tier 1) 2 (Medium Impact(Tier 2) 3 Low Impact(Tier 3) p
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 6 of 11
f sectl�n
�.�..�._..�.....�..-a..�...�...._._.... p_..l..an�saVerifiede.dw �Field VerifiedFraming Rough-In Inspection Value Value ..� Co..ap.l���.s. ..,. �rn
.�Neo_.-t..s.._/A.._s..suraticns
lRel
403.4.1 Protection of insulation on HVAC ElComplies
[FR24]1 piping. 'nDoes Not
®Not Observable
[]Not Applicable
403,5.3 Hot water pipes are insulated to R- - -
' R- ,®Con'rpies
[FR1812 >_R-3. ElDoes Not
ONot Observable
Neat applicable
403.6 Automatic or gravity dampers are' ICzanplies
)FR1912 installed on all outdoor air Does Not
intakes and exhausts.
Not Observable '
0Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 7 ofll
section Plans VerifiedField Verified
Value
Value
-_�...�.._........ , ry ry Comments/Assumptions ts/Rssumptions
303.1INS All mlasulatioal�ns �ttion ,�. , ,,� Complies? Commen .��.._...._..,._w..y
stalled insulation is labeled ❑Complies
JIN1312 ;or the installed R-values ❑Does Not
provided. ❑Not Observable
'❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel ;❑Not Observable
*,
❑Not Applicable
303.2, Floor insulation installed per ❑Ccaaplies
402.2.8 manufacturer's instructions and ❑Does Not
[
IN2]1 in substantial contact with the
underside of the subfloor,or floor ❑Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
a
i extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
t]i requirement applies(FR10). ❑ Steel ❑ Steel []Not Applicable
303.2 Wall
is
instructions.per 'CoNie
[IN4] manufacturesEDoes Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High impact(Tier 1) 11 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 8 of 11
i Section Value Value . Complies?_. t
p Plans Verified Field Verified /Assumptions
& Re ID
402..1, Ceiling tion R-value.
R R- '❑ComiesSee
etoWe _�m����W-
g p p Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel []Not Observable
402.2.6
❑
[FI111 Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ;❑Complies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[F[17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
'leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
;occur during Framing Inspection.
403.3.2.1 ;Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1... ._
1 Programmable thermostats '❑Complies
[Fl 9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications, ❑Not Applicable
403.1.2 'Heat pump thermostat installed ❑Complies
[Fl 10]2 on heat pumps. " % ❑Does Not
❑Not Observable
CJNot Applicable
403.5.1 :Circulating service hot water ' ,❑Complies
[Fl 11]2 systems have automatic or ❑Does Not
accessible manual controls. "` ~'"
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 IMedium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 9 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Re .ID
403.6.1 All mechanical ventilation system ❑Complies
[17125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits per Table ❑Not Observable
❑
R403.6.1. Not Applicable
403.2 Hot water boilers supplying heat `❑Complies
[F126]2 through one-or two-pipe heating %❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
'temperature based on outdoor ,❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems " " ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the '
'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F12 9]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the
❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Demand recirculationwater ❑Complies
[F130]2 systems have controls that ❑Does Not
manage operation of the pump
and limit the temperature of the ❑Not Observable
water entering the cold water ❑Not Applicable
piping to <= 1049F,
403.5.4 Drain water heat recovery units ❑Complies
[F13 1]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 90%or more of permanent ❑Complies
[F16]1 fixtures have high efficacy lamps." ❑Does Not
❑Not Observable
❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. �' ��❑Does Not
❑Not Observable
" ;
section,
_ ,... Plansvalueverified lel Value'Verifiedw.,,,, 1p .
.. ... .. . �,,..,.,. ', ......._..... ........ i.... ...,..,,,... .��...,.... ..... Tr�S
1n1 lras etlara Prvisrans complies? rnrnentspAssarrr two
,1
Req.11)
3013,3 Manufacturer manuals for ElCom lies
[FI1813 mechanical and water heating ElDoes Not
systems have been provided.
E]Not observable
CNot Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: Patterson Walls House Report date: 11/07/22
Data filename: Page 11 of11
2018 IECC Energy
Effidency Certificate
Above-Grade Wall 25.90
Below-Grade Wall 0.00
Floor 22.20
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Window 0.36 0.30
Door 0.26
Skylight 0.43 0.22
Heating System•
Cooling System:
Water Heater:
Name: Date•
Comments