Loading...
HomeMy WebLinkAbout48434-Z ' TOWN OF SOUTHOLD rfat " � BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 48434 Date: 10/27/2022 Permission is hereby granted to:. Mattituck Plaza LLC PO BOX 77 Mattituck, NY 11952 To: Construct interior alterations to existing Unit#13, Nofo Optical, as applied for. At premises located at: 10095 Route 25, Mattituck SCTM # 473889 Sec/Block/Lot# 142.-1-26 Pursuant to application dated 8/5/2022 and approved by the Building Inspector. To expire on 4/27/2024. Fees: COMMERCIAL ADDITION/ALTERATION $721.20 CO-COMMERCIAL $50.00 Total: $771.20 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT F Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ' Telephone (631) 765-1802 Fax(631) 765-9502 https://www.soudioldtowlil-tv.p-ov b Date Received APPLICATION FOR BUILDING PERMIT Y For Office Use Only '^ PERMIT NO. 5 Building Inspector; AUG 0 202 Applications and forms must be filled out in their entirety. Incomplete BUILDING DEP applications will not be accepted. Where the Applicant is not the owner,an i<VN OF(.�rJUTHOLD Owner's Authorization form(Page 2)shall be completed. Date:8/5/2022 OWNER(S)OF PROPERTY: Name:Cardinale Management SCTM#1000-1000-142-1-26 Project Address: 10095 Main Road, unit 13, Mattituck Phone#:631-298-8494 Email:alanjr@cardinalemanagement.com Mailing Address: 10095 Main Road, Mattituck, NY 11952 CONTACT PERSON: Name:Michael Hand Mailing Address:PO 1256, Mattituck, NY 11952 Phone#:631-965-1947 Email:michael@mchdesignservices.com DESIGN PROFESSIONAL INFORMATION: Name:James Deerkoski, PE Mailing Address: Y 11952 260 Deer Drive, Mattituck, N Phone#:631-774-7355 =maiI-jdeerkoski@yahoo.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition MAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $15,000.00 Will the lot be re-graded? ❑Yes igNo Will excess fill be removed from premises? ❑Yes R No 1 PROPERTY INFORMATION Existing use of property:Business Intended use of property:Business Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to B this property? ❑Yes B No IF YES, PROVIDE A COPY. ❑ Check Box After Read!r1g: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Autl�oried Agent ❑Owner Signature of Applicant: Date: ` STATE OF NEW YORK) SS: COUNTY OF 3LIHOV44 Aviv,f-�fy SG N����It being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Ar U4-0 I (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of f+U&V 51 ,20 �y rY Public DAVID C.BARCZAK tiotery Public,State of NewYofk PROPERTY OWNER ' .T J R)ZAP I No.01 BA5023957 (Where the applicant is not the owner) Qualified InSuffolk County WMil *m Dow FoU 29. I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 guilding Department Application AUTHORIZATION (Where the Applkant is not the Owner) I A residing at MQ r) u � (Print property owner's name) (Mailing Address) a � ►`' P, do hereby authorize 1) 0) (Agent) ,..� , . (/l M 0 to apply on my behalf to the Southold Building Department. S-S-2022 �taers Signature} (Date) ,.-Pjan .r : -�-- (Print Owner's Name) r 161R. — / Cz X5255 0�--S 101A7/,Ax 3L Design Services It 11 . }` www.mchdesignservices.com >F phone: (631)298-2250 email: michael@mchdesignservices.com ----------------- 5'-0min. CABINET o m .-I "' RECEPTION ;E � C? 6'-9%" `° 7'-0" �" 10'-6" 6'-0" 10'-0" ; !: - - — 75' STORAGE TESTINGc� EXAM ROOM c � 4 OFFICE ROOM 00 O0 CONTACT ' LENS 15'-0"rA �\o ti N � T-0"` 10 - HALL - - - - - - - - - - - - - - - - \ - -- - - - - - - - - - - - _ - - - - - - - O SIDE WALK .�,.. ' I C0 HC CNTR HT _di _ �, I t PER CODE cY 1.j0 COUNTER WAITING i BATH BATH\ (HINGED) N2'-6" r _ o - 12'-0" 29'-2'/<" 6'-1%x" ~j O z, - /'� H LAB DISPLAY AREA O1 c ` 1 � Ld lr I CLOSET Cn I � � ^ O I T-5" ® hoz P Uzi EMERGENCY 1.NO STRUCTURAL CHANGES TO BE MADE EXISTING FIRE TO EXISTING BUSINESS SPACE(ALTERATIONS LIGHT SPRINKLER ONLY). Q E H OCCUPANCYOR 2.1HOUR FIRE RATED WALLS TOBEDBL5/8"TYPE-X Ln L PP OVED AS NOTED USE IS UNLAWFUL AREA TOTAL EXIT ® EXTINFIRE GUISHERNo GYPSUM WALLBOARD.(UL DES U305,U314 �1 r 1262.6 SQ. FT. SIGN 3.EXISTING SPRINKLER HEAD LOCATIONS TO COMPLY O DATE ,e. -�-�.P.# WITHOUT CERTIFICATE WITH NFPA REQUIREMENTS. 0 FEEIP BY: OF OCCUPANCY TRAVEL 4.INSTALL AND ALTER LIGHTING AND OUTLETS PER — - — SMOKE O NOTI Y BU LDING DEPARTMENT AT PATH DETECTOR O CODE AND OWNER SPECIFICATIONS FOR MEDICAL PROPOSED F LO 0 R PLAN 631-765-1802 8AM TO 4PM FOR THE AND OFFICE EQUIPMENT. FOLLOWING INSPECTIONS: SCALE: 1/4" = 1'-0" 1. FOUNDATION-TINO REQUIRED FIRE '��71 RCO 6.SMOKE AND CO DETECTORS TO 7. INSTALLED AND ECTIION CARBON MONIXIDE REPLACED PER TING OF ICC ASRE 2009 CODE.FOR POURED CONCRETE IRE(�,UIRE� DETECTOR INSTALL FIRE EXTINGUISHERS AS REQUIRED. 2, ROUGH-FRAMING&PLUMBING �EF�RE 7.EMERGENCY LILTING AND LIGHTED EXIT SIGNS TO A ' 3. INSULATION OPENING BE INSTALLED AS REQUIRED. 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. 8.OWNER TO NOTIFY SCHD FOR PROPOSED WORK. ALL CONSTRUCTION $HyA,LL MEET THE REQUIREMENTS OFTHE LODES OF NEW INSTALL JOINT PROTECTION AT INTERSECTION YORK STATE NOT RESPONSIBLE FOR EXISTING ROOF DECK TH ROOF/WALL PER 707.8,71S DESIGN OR CONSTRUCTON ERRORS �'�`"' P�Ql1:RED CONCRETE OVER B-LOK STEEL DECKING FIRE-RESISTANT JOINT SYSTEM 9 r ( � EXISTING STEEL WEB ROOF JOISTS EXISTING DROP CEILING A' L. CCU�S OF (PATCH/REPAIR AS REQ.) ( DRAWN BY: MH FC7W YURK&ATE & TOWN CODES 1, A5 NE:QUIF(E:D AND CONDITIONS OF Additional , �pF NEpi,y SOUTHOLDTOWN ZBA Certification C-:) N, DEER 10/07/2022 SOUTHOLD TOWN PLANNING BOARD May Be Required. g°s� NYS 721,NON-BEARING WALL :'; ,. y�� W SCALE: SEE PLAN 3 HOUR,721.1(2) L ,I SOUTHOLO TOWN TRUSTEES 1D"CMU,UNFINISHED 01 R� 4 w REINFORCE WITH 7- ^,+��II % 2 HORIZONTAL ER ' ^ AT COURSES,MORDTAR �`Q •v0 (13 v.i.�.DEC �, V ATALLJOINTS A �'°CESS NP SHEET NO: PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE EXISTING CONCRETE SLAB CERTIFICATE OF OCCUPANCY 24"SOLDER USED IN WATER w/(/(X3)#)# `4 COONT.NTFTG BAR SUPPLY SYSTEM CANNOT A 1 EXCEED 2110 OF 1% LEAD. M C H- Design Services www.mchdesi-qnservices.com phone: (631)298-2250 email: michael@mchdesignservices.com V Z 53'_6," O �- Cn < .0!� r.-, �4 NF-1 p4 a azo� W A a SIDE WALK w V � � T REMOVE 1� o F, �-' Cly o 0 6'-6'/." SS'-2" O EXISTING FLOOR PLAN SCALE: 3/16" = V-0" DRAWN BY: MH F OF NEI,k 10/07/2022 �P �, DEEB O,f' CO ` - �o *N�/ SCALE: SEE PLAN Ld mil ttRRy� 4 IAJ K� ° SHEET NO: AROFESSI NP M C H Design Services 803.13 Interior Finish Requirements Based on Occupancy 1 HOUR FIRE WALL REQUIREMENTS Interior wall and ceilingfinish shall have aflame spread index not greater than that specified in Table 803.13 for the group and location CLIMATIC & GEOGRAPHIC DESIGN CRITERIA designated.Interior wall and ceiling finish materials tested in accordance with NFPA 286 and meeting the acceptance criteria of wt.7 •5/8"SgErRoac FtEm Core panels,or UL Des 0305, 32 RAL-TL11-129 A-59 GROUND WIND SEISMIC FROST WINTER ICESHIELD FLOOD 5/8"SHEET=UtraLight panels FREm X U314 Based on 5/8"SiiiE mcK FFEcocE core www.mchdesignservices.com Section 803.1.1.1,shall be permitted to be used where a Class A classification in accordance with ASTM E84 or UL 723 is required. T' '' ''- - show SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT - g ' or 5/8"Feam panels panels,no sound bat LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED HAZARDS TABLE 803.13 44 —2 X 4 wood stud 16"or 24"O.C. phone: k —optional insulation 33 RAL-TL11-172 20 LBS. 120 B SEVERE 3 Fr MODERATE SLIGHT TO 11 NONE (631)298-2250 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY < Based on 5/8"SHE Rom UltraLtht Panels TO HEAVY MODERATE SPRINKLEREDI NONSPRINKLERED FIrecode X,no sound bat email: ........................................... ....................... Corridors and Corridors and 34 RAL-TL11-173,RAL-TL11-130 michael@mchdesignservices.com GROUP Interior exit stairways Rooms and Interior exit stairways and Rooms and Based on 5/8"SHaTwcK FvFm core s and exit enclosure for exit enclosed ramps and exit enclosure for exit enclosed DESIGN CRITERIA BLDG. GORE NYS 2020 IBC and ramps access stairways P access stairways panels IN 518"SHEETI�dC UtnaLlght Panels passageways°•b and ramps spacesc passageways'-b and ramps spacesc FRr wr X with R-11 fiberglass sound bat FRAMING ELEMENTS AS PFER FLOOR PLANS.CROSS SECTION AND GENERAL NOTES ......................I.................................................. EXT.BALCONIES 100 37 RAL-TL11-081,RAL-TLI1-084 A-1&A•2 B e c A Ad Be Based on double layer one side 5/8" DESIGN LOAD CALCULATIONS DECKS I00 ROOF (GROUND SNOW LOAD) 45 SHrmm FfFm core panels or 5/8" (LIVE LOADS PSF) ALL FLOOR LOADS 100 A-3f,A-4,A-5 8 B C A Ad C SHEUMCK UltraWl't Panels FrwoDE X with R-11 fiberglass sound bat STAIRS loo GAURDRAILS(ANY DIRECTION) 200 B.E,M,R-1 B C'" C A B C EXPOSURE CATAGO Y L LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION R-4 B C C A B 8 (ROOF-FOUNDATION) DETAIL PAGE t GENERAL NOTE PAGE Vol NAILING SCHEDULE SEE GENERAL NOTE AGE V+ F C C C B C C EGRESS S FLOOR ANS AND WINDOW SCHEDULE H 8 B FIRE PROTECTION B CB A A �m SEE FLOOR PLANS (SMOKEt 02 GTO S) TRUSS DESIGN N/A-STEEL TRUSS CONSTRUCTION I-1 B C C A 8 B O ENERGY CALCULATIONS COMCHECK 1-2 B B 13h,1 A A B BATHROOM SPECIFICATIONS N.T.S. ^� I-3 A 141 C A A B INTERIOR WALLS AND CEILING PER TABLE 803.13 NYS CODE VERTICLE EXITS AND EXIT ACCESS CORRIDORS ROOMS AND M 1-4 B B Bh'I A A B All work to be compliant to ICC/ANSI 2009 60"MIN. EXIT PASSAGEWAYS AND OTHER EXITWAYS ENCLOSED PASSAGEWAYS I�il w R-2 C C C B B C Water Supply and drain pipes under lavatories 24- 2"d sinkshll binsulated or otherwise M B C N ansae nsue36"GRAB BAR J O R•3 C C C C C C ® (33-36"ABOVE FLOOR) configured to protect against contact. There S c C c B Bshall be no sharp or abrasive surfaces under 6-Is BUILDING TYPE PER NYS 602 MEANS OF EGRESS OER NYS 1003 lavatories and sinks. ALTERATION LEVEL PER 803.5 EXITS PER NYS 1005 Ed U No restrictions No restrictions Accesible lavatories and sinks are to comply Fri F-1 a.Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 with Section 606 . FRONT ELEVATION �wj square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or A clear floor or ground space complying O H 3 p over furring strips applied to a noncombustible base and fireblocked as required by Section 803.15.1. with Section 305. ositioned for foward r , W approach,shall be provided. Knee and toe VERT. clearance compling with Section 306 2"MAX BAR Z b.In other than Group 1-3 occupancies in buildings less than three stories above grade plane,Class B interior 42•MIN. finish for nonsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted In shall provided. . SITE DATA & ZONING INFO ~ The frroo nt of lavatories and sinks are to be ® H interior exit stairways and ramps. Q 34 inches maximum above the floor or [� c.Requirements for rooms and enclosed spaces shall be based on spaces enclosed by partitions.Where afire- ground, measured to the higher of the OCCUPANCY CALCULATIONS (TABLE 1004,1,2)fixture rim or counter surface. U F-1r j Ln resistance rating is required for structural elements,the enclosing partitions shall extend from the floor to Faucets shall comply with Section 309. UO g comply g P Hand-operated,self-closing faucets shall SIDE ELEVATION BUILDING AREA: 1262.6 SQ. FT. the ceiling. that do not com I with this shall be considered to be enclosing spaces and the rooms VolO or spaces on both sides shall be considered to be one room or space.In determining the applicable remain open for 10 seconds minimum. OCCUPANCY: BUSINESS GROUP B o 'r") requirements for rooms and enclosed spaces,the specitic occupancy thereot shall be the governing tactor Sinks are to be a maximum 6-1/2"deep. regardless of the group classification of the building or structure. Multiple compartment sinks shall have O at least one compartment complying with —1 OCCUPANCY LOADS: 1262.6 SF / 1/150 = 8 d. Lobby areas in Group A-1,A-2 and A-3 occupancies shall be not less than Class B materials. the requirement. - 34" MAX TYPE OF CONSTRUCTION: TYPE 3 e.Class C interior finish materials shall be permitted in places of assembly with an occupant load of 300 � O persons or less. ALTERATION LEVEL: 2 HEIGHT OF LAVATORIES AND SINKS f.For places of religious worship,wood used for ornamental purposes,trusses,paneling or chancel furnishing shall be permitted. a g.Class B material is required where the building exceeds two stories. LEGEND h.Class C interior finish materials shall be permitted in administrative spaces. WATER WATER EMERGENCY EXISTING FIRE CLOSET CLOSET SINK SINK LIGHT SPRINKLER I.Class C interior finish materials shall be permitted in rooms with a capacity of four persons or less. LAVATORY LAVATORY F.A.I. IRE p�] .A. EXIT 1�{� I�Q�/J j.Class B materials shall be permitted as wainscotting extending not more than 48 inches above the finished SIGN �u EXTINGUISHER floor in corridors and exit access stairways and ramps. 1jL4 _e,2 4 2 2 2 1 CO SOKE DRAWN BY: MH k. Finish materials as provided for in other sections of this code. 4 4 TRAVEL DETECTOR S O 1.Applies when protected by an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 4 T �� CARBON MONIXIDE 10/07/2022 903.3.1.2. lJ TO APROVED DETECTOR C� 4"C.I. SEWER m.Corridors in ambulatory care facilities shall be provided with Class A or B materials. TRAP HOUSE F OF NEWSCALE: SEE PLAN DEFR yO,Q O SHEET NO. rnz �p 4'0c3c) �� A�OFESSI NPS