Loading...
HomeMy WebLinkAbout2013 4th Qtr DVIRKA AND M-BARTILUCCI CONSULTING ENGINEERS A DIVISION OF D&B ENGINEERS AND ARCHITECTS,P.C. 330 Crossways Park Drive,Woodbury,New York 11797-2015 516-364-9890.•718-460-3634•Fax:516-364-9045•www.dvirkaandbartilucci.com Board of Directors Henry J.Chlupsa,P.E.,BCEE President&Chairman Steven A.Fangmann,P.E.,BCEE December 19 2013 Executive Vice President , Robert L Raab,P.E.,BCEE Vice President. James'Bunchuck, Vice Presidents Richard M.Walka Solid Waste Coordinator _ Senior Vice President Town of Southold D.SW Joseph H.Marturano :Senior Vice President P.O.Box 962 Dennis F.Koehler,P.E. CutChogue, NY. 1193 5 " Senior Vice President Garrett M.Byrnes,P.E. Vice President Re: Town of Southold Landfill RobJ.DeGiorgio,RE.,CPESC Vice President Landfill Gas Monitoring.Program, Fourth Quarter 2013 Stephen M.Dudar,P.E. Vice President D&B No. 3175 Thomas P.Fox,P.G. Vice President William D.Merklin,P.E. Dear Mr. Bunchuck: Vice President Michael Neuberger,P.E. Vice President On November 23, 2013, Dvirka and Bartilucci Consulting Engineers (D&B) Ken-Vice President P.E. completed the Fourth Quarter 2013 landfill gas monitoring event for the Town of . "Vice President Theodore S.Pytlar,Jr. Southold Landfill located on Middle Road(CR 48) in Cutchogue, New York. The Vice President Brian M.Veith,P.E. landfill;gas..,monitoring was.,conducted utilizing a GEM 2000 Plus Landfill Gas Vice President Surveyor at.the.existing,15.gas monitoring wells (GMW-L,to,1,5.jocated along the. Charles J:Wachsmuth,P.E. 'Vice President southern, eastern.-and northern boundary. of,the landfill,. waste mass). .Weather Dir.of Architecture conditions on.November 23, 201.3',--were observed.to be clear-and approximately . Andre H.Keel,R.A. 43 deees Fahrenheit with light-winds heading.east. Senior Associates Steven M.Cabrera Christopher M.Clement Enclosed with: this letter are Figure 1 and Table 1. Figure 1 shows the Ellen R.DeOrsay approximate locations of the gas monitoring wells-, and Table 1 lists .the gas Matthew R DeVinney,P.E. monitoring wells and their corresponding temperature and d levels of o)(ygen; Frank DeVita Joseph A.Fioraliso,P.E. carbon,monoxide, lower explosive limit (LEL) for methane and hydrogen sulfide Michael R.Hofgren 'as measured on November: 23, 2013. As indicated in Table .1, there 'was a Christopher M.LeHanka detection of methane eater than 100%of the LEL'at as:irionitorin well GMW- Richard W.Lenz,P.E. gr g g Olga Mubarak)aramillo 6, located along the eastern boundary of the waste mass.'GMW-6 has exhibited a . Philip R.Sachs,P.E. trend of•elevated LEL detections-for methane, often" over 100%, suggesting that Daniel Shabat,P.E. gas migration is occurring beyond the boundary of the waste mass in this area. It. Associates should be noted however, that GMW-6 is not located at the property boundary, Rudolph F.Cannavale � � 1� h y Y,. Christopher W.Francis which is approximately 250 feet to the north and 350 feet to the east of GMW-6. Christopher Koegel,P.E. In addition, methane was not detected at.GMW=7,,located to the north-of GMW-6 James J.Magda Michele Mastrangelo at the .northern ,property boundary,.,- or-:,within,. the: :scale , house, located Roger W.Owens approximately,100 feet,to the.south o.f.GMW-6. The scale house is,the closest on- Robbin A.Perrella site structure to-GMW-6, and'methane was,not:detected within•the�brawl s ace or Edward J.Reilly . . - .. . - ... , �p. stephenTauss occupied-area of the structure., Jason R Tonne ; DVIRKA AND BARTILUCCI CONSULTING ENGINEERS James Bunchuck, Solid Waste Coordinator Page Two Town of Southold DSW December 19, 2013 In an attempt to mitigate the elevated methane levels detected in GMW-6, the Town installed wind-driven turbine exhaust fans on the three landfill gas vents located nearest to GMW-6 and within the landfill mass. The turbines were installed in September 2012, following the third quarter 2012 landfill gas monitoring event. In order to determine the effectiveness of this remedial measure, D&B has been measuring both the LEL and percent gas levels for methane at GMW-6 since the third quarter of 2012. The current percent gas level in GMW-6 is 13.0%, which is lower than last quarter's 13.9% and significantly lower than the 22.7% measured in the third quarter of 2012 prior to the installation of the turbines. D&B will continue to monitor the LEL and percent gas levels for methane at GMW-6. Consistent with recent monitoring events, the remaining gas monitoring wells did not exhibit LEL detections for methane. Carbon monoxide and hydrogen sulfide were not detected in any of the gas monitoring wells, and oxygen levels were detected at and below typical atmospheric levels. The next quarterly round of monitoring is expected to be conducted during the First Quarter of 2014. If you have any questions,please contact me at(516) 364-9890, Ext. 3091. Very yours truly, a.4 1..�, Anthony Caniano Project Manager AMC/PBt/cf, nc Enclosures cc: T. Fox (D&B) P. Barusich(D&B) 43175\AMC 13 Undoc-08 t r � ���l�it�'U 11,,,rll�'+ jl,Its l ���"�'��`"'t�-��--`�_�-•ir:--'--.�.� �. as..�____��t�'� �jk tf. ,r- .:rte^- "��--�`�''���`�-`�_�-•=.--� -�`- . ��t ilk DONE '�. �_-_.����`r r r �r �t+� "�`-• -^��.�`���.•�„``-"�\�_ `_-•< r-,--� -moi,:,.-7�.�, SROh, E +'����/r�y /rd A j a' z".5�,�, �x3:,f/•'\y .r r ,rl ft 7 � b `i�. _I r ,,.� i ' My.r4� II' f�!'f rillf� 11111i I till BONN IN � v a nl19 � 1 - MR Im AX �-� iC�ActtNK r�i-arai++c�cc-Ci -:+[.?�r•�ry,��•�� �`'' e r >>is��. ,.��-"--� '�'•c"'�t,.r►-'+mac �' r��� ? ` _.••`�'r.""air fri� �3:n 1 1 / r—� SOLItHOLD LANDFILL Dvirka CLITCHOGUE,NEW YORK • 'd • 'Bartilucci LAN DFIL L GAS MONITORING D10.106 irneem and Architects,P.C. •LOCATIN.MAP- TABLE'1 TOWN OF SOUTHOLD LANDFILL LANDFILL GAS MONITORING PROGRAM FOURTH QUARTER 2013 MONITORING EVENT Sampling Date: November 23,2013 Parameter Unit GMW-1TO GMW-3 .GMW-4 GMW-5 GMW-6 GMW-7 GMW-8 GMW-9 GMW-10 GMW-11 GMW-12 GMW-13 GMW-14 GMW-15 Temperature °C 7.2 7.2 6.6 7.2 7.2 5.6 6.1 6.1 6.6 7.2 7.2 7.2 6.6 6.6 Oxygen % 19.9 21.1 21.2 13.5 1.5 19.1 20.7 21.3 21.7. 14.9 18.0 17.1 18.0 20.0 Carbon Monoxide m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Lower Explosive Limit-Methanej% 0 0 0 0 >100* 0 0 0 0 0 0 0 0 0 H dro en Sulfide m 0 0 0 0 0 0 0 0 •0 0 0 0 0 0 NOTES: *: Measured at 13.0%gas. Typical atmospheric levels of oxygen range between 19.5%and 23.5% °C =Degrees.Celsius %=Percent ppm=Parts Per Million \\Dbfs1yobs\..•HazWaste\3175(Southold Land011)\4th Quarter 2013\Southold Landfill-Landfill gas monitoring Q42013 Page 1 of 1 12/6/2013