Loading...
HomeMy WebLinkAbout2006 3rd Qtr r U2AC-7ROUP ACE A EF SUPPOF7TII G EXC�L[sENCEdN.ENG�N.EERING Holzmacher, McLendon &Murrell, P.C. ►1-112M Associates, Inc. 1-12M Labs, Inc. ► 1-112M Architects&Engineers, Inc. September 25,2006 575 Broad Hollow Road, Melville, New York 11747 631.756.8000, Fax:631.694.4122 www.h2m.com James Bunchuck Fa n .01 Southold Solid Waste Coordinator �VfPO Box 962 Cutchogue,New York 11935-0962 2 6 2006 Re:. Cutchogue Landfill Gas Well Monitoring Program DEPT. OFSOtU H0-L—D SOHT 06-01WASTE Dear 1Ntn Bi-ir'h2jok: As detailed in our letter proposal dated May 23, 2006 our office conducted a round of monitoring for the methane gas well monitoring program for the Town of Southold Sanitary Landfill located on Middle Road (CR 48) in Cutchogue. The monitoring program was conducted on September 12, 2006 for the fifteen(15) gas monitoring wells at the southwest, south and southeast perimeter of the landfill. Figure 1 is provided which indicates the location of the gas monitoring wells at the landfill. The field program included the measurement of oxygen and combustible gases for each of the wells as required by NYSDEC. The H2M personnel utilized an MSA Orion Multi-gas Detector to monitor for oxygen and.combustible gas (percent of lower-explosive limit'[LEL]) from the sampling ports of the gas monitoring wells.- The following table summarizes the findings of the September 12,2006 gas monitoring program: Percent Gas Probe LEL Percent Oxygen GMW-1 0 19.5 GMW-2 0 20.5 GMW-3 0 19.6 GMW-4 0 20.1 GMW-5 4 11.3 GMW-6 98 11.9 MI's'-' ;; 5.3 GMW-8 0 15.3 GMW-9 0 19.2 GMW-10 3 14.4 GMW-11 >100 0.4 GMW-12 0 17.4 GMW-13 0 17.5 GMW-T4 0 18.0 GMW-15 0 18.4 The results indicate that there`is-currently a threat of combustible gas migrating beyond the boundary.,of the landfill mi ""fie!vicinity of GMW-6 and GMW-11 located in the northeast and east portions of the ENGINEERS ► ARCHITECTS I\ SCIENTISTS \ PLANNERS \ SURVEYORS `• U2A(;ROUP James Bunchuck September 25,2006 Page 2 landfill. The test results in the June 2006 round of monitoring were consistent with these results for all the gas monitoring wells. I recoinmend that the Town consider an'off-site gas monitoring program for those properties in the vicinity of GMW-6 and GMW-11. Our office is available to discuss the options with the Town for the off-site monitoring. The next quarterly round of monitoring is expected to be conducted during December 2006. If any questions arise concerning the gas monitoring program, please contact our office at(631)756-8000 Ext. 1610. Very truly yours, HOLZMACHER,MCLENDON&MURRELL,P.C. George W.Desmarais,P.E. GWD:gjc cc: Town Board Patricia A. Finnegan, Esq. XASOHT(Town of Southold)\2006\Gas Well Monitoring Program 9-25-06.DOC