Loading...
HomeMy WebLinkAbout47996-Z r�r1Z �SUfFOI,� Town of Southold 8/16/2022 P.O.Box 1179 N z 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43337 Date: 8/16/2022 THIS CERTIFIES that the building HVAC Location of Property: 16495 CR 48, Cutchogue SCTM#: 473889 Sec/Block/Lot: 101.-1-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/23/2022 pursuant to which Building Permit No. 47996 dated 6/24/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as-built"HVAC system and water heater replacement to existing single family dwelling as applied for. The certificate is issued to Fliss,Amy&Corey of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47996 7/29/2022 PLUMBERS CERTIFICATION DATED 7/29/2022 rad Piecith ho ed Signature TOWN OF SOUTHOLD �SOEFacq�oG$ moo BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE SOUTHOLD', NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47996 Date: 6/24/2022 Permission is hereby granted to: Fliss, Amy 16495 CR 48 Cutchogue, NY 11935 To: ' Legalize as-built HVAC system and water heater replacement at existing single family dwelling as applied for. Additional certification may be required. At premises located at: 16495 CR 48, Cutchogue SCTM #473889 Sec/Block/Lot# 101.4-17 Pursuant to application dated 6/24/2022 and approved by the Building Inspector. To expire on 12/24/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector Of SO!/r,�ol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G sean.devlin()town.southold.ny.us Southold,NY 11971-0959 OIyCQUN���� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Amy FIISS Address: 16495 CR 48 City,Cutchogue St: NY zip: 11935 Building Permit* 47996 section: 101 Block: 1 Lot: 11935 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Owner License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures 1 Bath Exhaust Fan Service 3 ph Hot Water Gas GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt 1 Recessed Fixtures CO2 Detectors Sub Panel 100A A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4 4'LED Exit Fixtures 11 Pump Other Equipment: Car Charger Outlet, 100A Sub Panel 24 Circuit/ 5 Used Notes: " AS BUILT NO VISUAL DEFECTS " HVAC, HW and Sub Panel Inspector Signature: Date: July 29, 2022 S.Devlin-Cert Electrical Compliance Form oho sDU��Q� Town Etat!AnnexTateptioae(631)765-1 54375 Main hoard � + , Fax(631)765-9502 P.0_Sox 1179 Southold,NY 11471-0959 :r< of s DD , 7 _ D i A U G 1 1 2022 BUILDING DEPT. TOWN OF SOUTHOLD TOWN OF 5O'""OLD Building Permit No. 4—f / Ovmer: I ss - (Flease print) I Certify that the solder used in the water supply system contains less than 2110 o€1% lead. r Iut bens Signafi e) Swom to before me this dayfll` tSZ� .20 � gu�gN A-fi= yPubliie,Std .ot-Newlfask Qudfiedjn SoffbIk', urd1► �� Notary Public, _ __. trOuillY , ho`L�aOF SOOI,��� TOWN OF SOUTHOLD BUILDING DEPT. `yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [V1 FINALf�VW [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL R ARKS: t - DATE �I y0'l•?i INSPECTOR OF SOUTyO� - # # TOWN OF SOUTHOLD BUILDING DEPT. coutom 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: ,A- v 4r DATE INSPECTOR } 5 3M1 rr `M 1 • r t .s + � ! r Vim► r z' -� �� / � � V � • I I , � � �� '_� � I � � j �� !� '.�... •..... » �;�. ,,_ 1 ,� �� , i �+• t� � �� i/� 3 1 � `� V i ! + 1 � � f f. y �{,� � __ FIELD INSPECTION REPORT DATE COMMENTS \ �!b FOUNDATION (1ST) 30 �3 -------------------------------------- FOUNDATION (2ND) z 0 N ROUGH FRAMING& PLUMBING r INSULATION PER N.Y. y STATE ENERGY CODE b 1lot �vw st FINAL • AD ITIONAL COMMENTS Z h 0 z rn � b �O x tyy� t" x e b H Ojos co TOWN OF SOUTHOLD—BUILDING DEPARTMENT y t� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownnv_.vov Date Received APPLICATION FOR BUILDING PERMIT Far Office Use Only E PERMIT N0. Building Inspector: ® JUN 2 3)L122 Applications'and forms must be filled out in their entirety.Incomplete LID applications will not be accepted. Where the Appli.ca'nt is not the owner;.art BUILDING DEPT: Owner's Authorization form(Page 2)shall'be completed: " "a TOWN OF SOUTHOLD Date: 6 -,L ..OWNER( OF PROPERTY: Name: # 1000- SCTM R� .__ Project Address: Phone#: Email: Mailing Address: / �� .....('2 . -•__.._.._. _..__..._.. CONTACT PERSON:. Name: Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION•. ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: IjQOther 144' rC , bAW 4 044-,M i5/&R'ca-/ tvog< $ Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes ❑No PROPERTY INFORMATION Existing use of property: ', Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes k,No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by;1054 Chapter236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the,issuance of a Building Permit pursuant to•the Building Zone Ordinance of the Town of Southold,Suffolk,County,New,York and other applicable Laws,Ordinances or Regulations,for the.construction of buildings,- additions,alterations or for removal or demolition as herein'described,,The applicant'agrees to comply with all applicable laws;.ordinances;building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section`210.45 of the New York State Penal Law. Application Submitted By((pnt me): S ❑Authorized Agent Nowner Signature of Applicant: Date: STATE OF NEW YORK) SS: COU TYOF SUFE=nI Q, f�!-1 ;S,5 being duly sworn, deposes and says that(s)he is the applicant (Name of indi idual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1 day of e\t_ 20 d a Notary Public PROPERTY OWNER AUTHORIZATION Notary Publli Diane Wilhelm c State of NY (Where the applicant is not the owner) No.otwi6209496,County ofS one Commission Expires Juty27, � I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 �c�UFtt#� C BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD A Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger-6a southoldtownny.gov – seand(cD.southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: e-Vt, Electrician's Name: License No.: Elec. email: Elec. Phone No ' -,� NZI request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) e. Name: 0azC'yFl is S Address: Cross Street: ryI fA h Phone No.: 6 / BIdg.Permit#: q3 Gj 9(P email: F I i SS Cprorr I;re,, A67 - Tax Map District: 1000 Section: I o l Block: I Lot: I BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): �2tr+eve. �XiS�ivuj Ia b4c `FravK "D"Dep/►ice. („r f On4�e�r,�av, 5ystern� " v�srr� tl /V`w r`-Jots Pr Sug-PAV)d rv� �rAR.4�_ Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size 1-11 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: ® PAYMENT DUE WITH APPLICATION fyr'�Vf otA- BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD { Town Hall Annex - 54375 Main Road - PO Box 1179 r CA) �o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roaerr(c southoldtownny.gov seand(a�southoldtownny.aov �;. APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: C Electrician's Name: License No.: Elec. email: Elec. Phone No _� ! 0 N�I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Rc'q is S Address: Cross Street: Phone No.: (� BIdg.Permit#: '� G�9 email: cpron (;v,`.., Af;, Tax Map District: 1000 Section: 0 Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): - vi s t to I/ New, ICO A PHv►c.( r o\ tZ Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ 'YES K-NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES QNO Issued On Temp Information: (All information required) Service Size 1-11 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[—]Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's .� I ttt \ Surface I Sconces ` H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon . Micro Generator: Combo Cooktop Transfer AC AH Mini Special: CO.%r Comments: % c i 4 � OCCUPANCY OR : APPR VED as NOTED USE IS UNLAWFUL � FATS o # WITHOUT CERTIFICATE' [NOTIFY EVIL®I�I �Y.C DEPARTMENT AT OF OCCUPANCY 765-1802 9 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. F()UN AT1ON - Tu' REOUIPED 2 s. 1K,SUL AI'40r1 4. FINAL - CONSTRUCTION MUST 13E COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIIIEME14TS OF THE N.Y. STATE CONSTRUCTION 8L ENERGY COMPLY WITH ALL CODES OF CODES. NOT FOR NEW YORK STATE & TOWN CODES DESS GIN OR CONSTRUCTION ERRORS AS REQUIRED AND CONDITIONS OF SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN,TRUSTEES NN.S.DEC Additional Certification May Be Required. RWMC&Stam REQUIRE® i:. NaVIeN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI 221.10.3-CSA 4.3-2015 standards for both indoor or outdoor installations(with , t: optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of 24 ft* W (*see Installation Manual foradditional information) •Compatible with 2"PVC vent up to 60 ft**and 150 ft** using 3"PVC vent(**with'no elbows) - •Gas Input Ranges ;} NPE-150-120,000 to 18,000 BTUh a Diagnostics Up NPE-160;150,0.0.0_to 15,000 BTUh._�. { NPE-210-180,000 to 19,9.00.BTUh-- Information O Down NPE-240-199,900 to 19,900 BTUhz''- °1 _ ,--.-,�y� Beset PowerON/OFF •Hot Water Flow Rate Capacity(*based on 35°F temperature rise) NPE-150-6.8 GPM NPE-180-8.4 GPM �. : ;.,=g :<} .-y.i`i ----,, � �Y •,��;�, == Built-In Control Panel [NP_E-210-10.1 GPM NPE-240-11.2 GPM with Diagnostics Sleek Design-Compatible with •Dual Primary and Secondary Stainless Steel Heat 2"PVC Vent and 112"Gas Pipe Exchangers for optimum efficiency and durability •Built-in Control Panel-allows adjustment of temperature settings and displays the operating status and error codes t Indoor and Outdoor o o • p(,FloVi -Technology-"A"models come included with Venting Options built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide rHake cap maximum comfort rCoupiing- 2,Pipe Outdoor •INTELLIGENT Preheating-recognizes hot water usage patterns Ventrap to intelligently provide hot water when needed(Optional tor"s*models) •Temperature Options -available temperature settings for , Residential applications range from 98"17 up to 140C17 with high i temperature Commercial mode capable of up to 182CF •Ready-Link Cascade Compatible for up to 16 units for increased hot water production Non-Direct Vent(Indoor) Non-Direct Vent(Outdoor) •Common Vent Compatible-allows for cascade systems to use a Direct vent(Indoor) single exhaust and/or intake pipe for up to 8 units with the use of the Common Vent Backflow Damper Collar Kit(#30014367A) %a •Compatible with NaVifihk Wi-Fi Control(uPBCM-A5-001) �Esto" •Freeze Protection-maintains normal operation during freezing ambient temperatures down to-5"F(standard on all models) `Far1Ft`°® CERTIFIED •Uniform Energy Factor Ratings for NG and LP units NPE-180A/210A/240A-0.96 UEF (0.97 EF for Canada) AL ILJDF , NPE-150S-0.96 UEF (0.97 EF for Canada) rw swam NPE-180S/210S/240S-0.97 UEF (0.99 EF for Canada) •Compatible with Natural Gas(NG)and Propane(LPG)*** (**•requires installation of Included Field Conversion Kit by a qualified gas servicer) job Name: •Approved for Installations on Mobile/Manufactured Homes Location: •Certified by CSA,MSF 5,AHRL AB1953 CA Low Lead,SCAQMD Engineer: (Rule 1146.2 Type 1-Complies with 14 rig/J or 20 ppm NOx @ 3%02) Wholesaler. •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential)**** Contractor. 8-Year Heat Exchanger and 5-Year Parts Warranty(Commercial)**** Model No.: (****see Navlen limited Warranty) Submitted to: •Optional accessories are available(see below) r 4L®®o CondensateNeutrabzer- RetnoteController Plum6tasyValveSet(3/4") Ready Link - 3 VentTerminatiorc (GXXX001322-SmgleUnit)= Outdoor VentKit� -External PumpWtre NR-20DU (30009323A Lead Free) {G10IX001324'-Upto6Units). CottununlgUontable (30010604A),' (GXXX001319) Capsand Will Flanges (300 09757A}- (30012581A-for Pipe Cover) .(GXXX001325-llptol6UMt;) iGXXX000596)_ (GXXX3873B) _ amaviem NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater Dimensions Specilications Erl 0 Pi.-I 6S, NPE-1805 kP NPE-240A; NPE 2405`, ,�' 'j, I -I , Heat 18,000- 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H -7L.0 Natural Gas Capacity 120,000 11 (input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H E Efficiency UEF(for NG&LP) 0.96 0.96 10.97 0.96 1 0.97 0.96 0.97 Ratings EF(Canada)(for NG&LP) 0.97 0.97 10.99 0.97 10.99 0.97 0.99 35*F(19*QTemp Rise 6.8 GPM 8AGPM(32Um) 10.1 GPM(38 Urn) 112 GPM(42 Urn) (26 Urn) Flow Rate 45,F(25*C)Temp Rise 5.3 GPM 6.5 GPM(25 Urn) 7.8 GPM(30 Urn) 8.7 GPM(33 Um) connection Size (DHW) (20 Urn) Alrintake (D 2' 67*F(36'0 Temp Rise 3.2 GPM 43 GPM 4.2 GPM 5.0 GPM 1 5.2 GPM 5.6 GPM 5.7 GPM (D ExhaustGasvent 2' 1 02 Urn) 06 Urn) 06 Urn) 09 Urn) (20 Urn) (21 Urn) (22 Urn) FR FIR Dimensions 17.3"(W)x 27.4"(H)x 13.2"(D) Weight 55 lbs 75 Ib5 67 lbs 82 lbs 75 lbs 82 lbs 75 lbs (25kg) (34kg) (30 (37 kg) (34kg) (37 kg) (34kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure 3.5 in WC-10.5 in WC (from source) Propane Gas Supply Pressure 8inWC-13inWC (from source) Natural Gas Manifold Pressure -0.04 in WC- -0.04 in WC--0.84 in WC -0.05 in WC--0.36 in WC -0.05 in WC--0.58 in WC (min-max) -038 In WC Propane Gas Manifold Pressure -0.04 in WC- 111� (min-max) -0.42 in WC -0.05 in WC--0.50 in WC -0.10 in WC--0.66 in WC -0.10!nWC--0.78!nWC 0 in Flow Rate 0.5 GPM(1.9 Urn),<0.01 GPM(0.04 Urn)option for"A"models* Cold Water Inlet 3/4 in NPT Connection Hot Water Outlet 3/4 in NPT Sizes Gas Inlet 3/4 in NPT Main Supply 120V AC,60Hz ov Power Supply Maximum Power 200W(max 2A),350W(max 4A)with external pump connected I Consumption Casing Cold Rolled Carbon Steel Materials Primary Heat Exchanger.Stainless Steel 2XW 77.rW 1'(3r (2 2..) Heat Exchangers W. Secondary Heat Exchanger:Stainless Steel 17TWRI.0 2"or 3"PVC,CPVC,Polypropylene Connection Size Exhaust 2.or 3"Special Gas VentType BH(Class 11,A/B/Q @O Hot Water Outlet (D 3/4"Coldwaterinlet 0 3/4" Venting 2.1 or 3"PVC,CPVC,Polypropylene Recirculation Inlet- (D 3/4" Intake 2"ora"Special Gas Vent Type 8H(Class 11,A/B/Q 1 .0 Gas Inlet (1)3/4" Vent Clearances 1 0"to combustibles Condensate outlet 01/2• Safety Flame Rod,APS,Ignition Operation Detector,WaterTemperature High Limit Switch,Exhaust Temperature High Limit Sensor, •Wmodefsordy Devices Power Surge Fuse *Avallable for"A'models configured In an optional Cornfartilowreckulation mode.Additional energy use willoccur when using recirculation. Gas-fired,tankless,condensing,wall-mounted water heater(s)shall he direct vent NPE Series models as manufactured by Navien,Inc.and are certified by CSA Group to the latest edition ofANSI standard Z21.1 0.31CSA 4.3.Water heater(s)shall have a 15 year limited Heat Exchanger warranty and 5-year limited Parts warranty(8yearHeat Exchanger and 5-year Parts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed.Water heater(s)shall have a nominal flow rate capacity of GPM1GPH at *F rise with rated input of B7Vlhr.Water heater(s)shall be vented with 2"PVC/CPVC vent pipe at a distance not to exceed 60'(or equivalent)with each elbow equal to 8'oftipe length or 3"PVCICPVC vent pipe at a distance of150'(or equivalent)with each elbow equal to 5'ofpipe length.Water heater(s)is rated for 150 PSI working water pressure and 300 PSI test pressure Gas supply pressure shall be 3.5"to 10.5"WC for naturalgas and 8.0"to 13.0"WCfor propane.Unit(s)shall have a steel case,dual stainless steel heat exchangers,eco premixed burner, negative pressure gas valve,dual venturi,314"inletgas connection,314"brass inlet/outlet water connections,water holding capacity of 0.6 gallons for the NPE-150S,1.0 gallon for the NPE-180A model CO.7gallonsfor NPE-1805 model),1.2 gallons for the NPE-210A/NPE-240A models(0.7 and 0.9 gallons for NPE-2105 and NPE-2405 models respectively),and a condensate collector.The NPE-1505 model weighs 55 lbs,the NPE-180A model weighs 75 His(NPE-1805 weighs 67 lbs),and the NPE-210A/NPE-240A models weigh 82 lbs(NPE-2105 and NPE-2405 weigh 75 lbs).Unit(s)shall include features such as an adjustment for installations at high elevation,temperature lockout and temperature optionsfrom98-120'Fin 17intervals and 125-140'Fin 5Fintervals.The unit(s)shaft include additional temperature options af150-180'Fin 107intervals, and 182"Fforhigh temperature commercial applications.All NPE A"models shall include an internal circulation pump and 0.5gallon buffer tank The waterheater(s)shall be controlled by an Internal circuit board that monitors the Inlet and outlet temperatures with installed thermistors,sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain th ennal combustion efficiency.Units)shall include safety features such as flame sensor system,high limit sensors,overheat prevention device,freezeprotection mode,and fan motor rotation detector.Multi-system(cascade)applications that require 2 to 16 units shall be installed by connecting the units using cable-only connections(Ready-Link).Cascade systems can be common vented with up to 8 units when a Common Vent Backflow Damper Collar Kit is installed.The water hea ter(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCA QMD rule 1146.2(Type 1)for Low NOx that complies with 14 nglj or 20 ppm NOx requirements @ 3%02. %avien reserves the right to change specifications at any time withoutpriornotice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 www.NavierLcom Rev.11/16 rRavE® moft Systam Cood'ohg Produj a3", XR 13 4TTR301&060 1'h—5 Tons PUB. NO. 22-1790-02-2607 (EN) TRINE® Features and Benefits • ClimatufP compressor • Tarpaulin gray cabinet with anthracite • Efficiency up to 14.00 SEER gray badge&cap • All aluminum Spine FinTM coil • High pressure switch • WeatherGuardTM fasteners • R-41 OA refrigerant • Quick-SessTM cabinet, easy service • 10 year limited warranty on access and refrigerant connections compressor,coil,5 years on parts with full coil protection (Residential Use) • DuraTuffTM base,fast complete drain, • 5 year limited warranty on weather proof compressor,coil,l year on parts �� "TM (Commercial Use) • Comfort R mode approved . Extended warranties available • Glossy corrosion resistant finish . S.E.ET.design testing • Internal high/low pressure and temperature protection • 100%line run test • 018,024,030 and 060 ship with start kit • Low ambient cooling to 55°F as shipped • Liquid line filter-drier • Low ambient cooling to 30°F with AY28X079 • Low ambient cooling to 0°F with BAYLOAM103 ©2007 American Standard Inc. All Rights Reserved 2 22-1790-02-2607(EN) rRavE® Contents Features and Benefits 0 General Data Product Specifications 4 A-weighted Sound Power Level [dB(A)] Accessory Description and Usage =5] ARI Standard Capacity Rating Conditions =5 Model Nomenclature Electrical Data L Dimensions F1--01 Mechanical Specification Options 11 22-1790-02-2607(EN) 3 7NME® General Data Product Specifications Model No.O 4TTR3018A1 4TTR3024A1 4TTR3030A1 4TTR3036 Electrical Data V/Ph/Hz O 200123011/60 200/23011/60 200/230/1/60 2081230/1/60 Min CirAmpac'Ity 9 12 15 20 Max Fuse Size(Amps) 15 20 25 35 Compressor CLIMATUFFO CLIMATUFP CLIMATUFFO CLIMATUFP-SCROLL RL Amps-LR Amps 6.4-38.6 8.8-57.8 11.1-63 15.4-83 Outdoor Fan FL Amps 0.7 0.7 0.7 0.7 Fan HP 1/8 1/8 1/8 1/8 Fan Dia(inches) 23.0 23.0 23.0 23.0 Coil Spine FnTm Spine FnTm Spine FnTm Spine FnTm Refrigerant R-410A 5/04-LB/OZ 5110-LB/OZ 5111-LB/OZ 6107-LB/OZ Line Size-(in.)O.D.Gas O 1/2 518 3/4 3/4 Line Size-(in.)O.D.Liquid O 114 5/16 5116 3/8 Charge Spec.Subcooling 100 100 100 10° Dimensions H x W x D(Crated) 38 x 30.1 x 33 38 x 30.1 x 33 38 x 30.1 x 33 42 x 30.1 x 33 Weight-Shipping 223 224 224 238 Weight-Net 195 197 197 209 Start Components YES YES YES NO Sound Enclosure YES YES YES NO Compressor Sump Heat NO NO NO NO Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Start Kit BAYKSKT260 Crankcase Heater Kit BAYCCHT300 BAYCCHT300 BAYCCHT300< BAYCCHT301 Seacoast lit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient tit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset© TAYREFLN5` TAYREFLN6' TAYREFLN2' TAYREFLN7' O Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on ARI Standard 210/240. O Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. O Standard line lengths-60'.Standard lift-60'Suction and Liquid line. For Greater lengths and rifts refer to refrigerant piping software Pub#32-3312-0t.(tdenotes latest revision) ®For accessory description and usage,see page 5. O'=15,20,25,30,40 and 50 foot lineset available. A-wei hied Sound Power Level d MODEL LEVEL d AME11GHTED FULL.OCTAVE SOUND POWER dB- 63 125 250 500 1000 2000 4000 8000 4TTR301RA1 76 47.5 60.4 63 70.3 69.8 69.3 59.3 50.9 4TTR3024A1 76 47.2 61.1 64.8 70.6 70.7 68A 57.9 50.6 4TTR3030Ai 76 49.3 61.1 66.2 70.3 70 67A 58 51.6 5.5 58.7 69.7 70 68.1 5 49.8 4TTR3042A1 76 54.9 58.7 1 61.6 67.2 69 1 87.7 50.4 537 4TTR3048A1 76 55.8 57 62A 67.5 70.2 1 87.4 1 81.1 54.2 4TTR3060B1 1 76 51.8 55 64 67.7 73.5 1 65.5 1 60.2 52.3 Note:Tested in accordance with ARI Standard 270.95.(Riot listed with ARI) 4 22-1790-02-2607(EN) TRANS® General Data Product Specifications Model No.O 4TTR3042A1 41TR3048A1 4TTR306091 Electrical Data V/Ph/Hz® 208 230/1/60 20800111M 208/230/1/60 Min Cir Ampacity 25 27 34 Max Fuse Size(Amps) 40 45 60 Compressor CLIMATUFF°-SCROLL CLIMATUFF®-SCROLL CUMATUFF0-SCROLL RL Amps-LR Amps 18.6-105 20.5-109 27.6-135 Outdoor Fan FL Amps 1.3 1.3 1.3 Fan HP 1/4 114 1/4 Fan Dia(inches) 27.6 27.6 27.6 Coil Spine Rnrm Spine FnTm Spine FnTm Refrigerant R-41 OA 7/00-LB/OZ 7/04-LBIOZ 8106-LB/OZ Line Size-(in.)O.D.Gas O 3(4 7/8 7/8 Line Size-(in.)O.D.Liquid O 318 318 318 Charge Spec.Subcooling 130 100 10° Dimensions H x W x D(Crated) 38.4 x 35.1 x 38.7 38.4 x 35.1 x 38.7 46A x 35.1 x 38.7 Weight-Shipping 258 261 287 Weight-Net 225 227 251 Start Components NO NO YES Sound Enclosure NO NO NO Compressor Sump Heat NO NO YES Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting tit BAYECMT001 BAYECMT001 BAYECMT001 Start Kit BAYKSKT260 BAYKSKT260 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 Seacoast lit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset© TAYREFW7' TAYREFLN3' TAYREFW3' Accessory Description and Usage ARI Standard Capacity Rating Conditions Anti-Short Cycle Timer—Solid state timing device that ARI STANDARD 210/240 RATING CONDITIONS— prevents compressor recycling until five(5)minutes have (A) Cooling 80°F DB,67°F WB air entering indoor coil,95°F DB elapsed after satisfying call or power interruptions.Use in area air entering outdoor coil. with questionable power delivery,commercial applications,long (B) High Temperature Heating 47°F DB,43°F WB air entering lineset,etc. outdoor coil,70°F DB air entering indoor coil. Evaporator Defrost Control—SPST Temperature actuated (C) Low Temperature Heating 17°F DB, 15'F WB air entering switch that cycles the condenser off as indoor coil reaches outdoor coil,70°F DB air entering indoor coil. freeze-up conditions. Used for low ambient cooling to 30°F (D) Rated indoor airflow for heating is the same as for cooling. with TXV. ARI STANDARD 270 RATING CONDITIONS—(Noise rating Rubber Isolators—Five(5)large rubber donuts to isolate numbers are determined with the unit in cooling operation.) condensing unit from transmitting energy into mounting frame Standard Noise Rating number is at 95°F outdoor air. or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit—Start capacitor and relay to assist compressor motor startup.Use in areas with marginal power supply,on longED- O �� linesets,low ambient conditions,etc. Extreme Condition Mount Kit—Bracket kits to securely mount condensing unit to a frame or pad without removing any ARI Standard panels.Use in areas with high winds,or on commercial roof 210/240 UAC tops,etc. 22-1790-02-2607(EN) 5 TRANE® Model Nomenclature Outdoor Units 4 T T R 3 0 3 6 A 1 0 0 0 A A High Efficiency T U D 1 B 0 8 0 A 9 H 3 1 A A Furnaces RefrigerantType Furnace Configuration 2=R-22 TU=Upflow/Horizontal 4=RA10A TO=Downflow/Horizontal Type 80%Premium ProductType X=90%Premium W=Split Heat Pump Number of Heating Stages T=Split Cooling 1=Single Stage Product Family 2=Two Stage Z=Leadership-Two Stage 3=Three Stage X=Leadership Cabinet Width R=Replacement/Retail A=114.5'Cabinet Width F-1 --�7 Family SEER B=Basic B=210 Cabinet Width (��) A=Light Commercial C=21.0'CaF-1binet Width D=24.5 Cabinet Width 0=10 3=13 6=16 Heating Input 1=11 4='14 8=18 080=80,000 BTUH 2=12 5=15 9=19 Major Design Change Split System Connections 1.6 Tons Power Supply/Fuel 0=Brazed 9=115 Vo Is/Natural Gas F=115 Volts/Natural Gas with Integrated IID Filter Nominal Capacity in 000s of BTUs Airflow Capacity for Cooling Major Design Modifications 36=3Ton Standard PSC Motor H3=3 Ton High Efficiency Motor Power Supply V3=3Ton Variable Speed Motor 1=200-23011/60 or 208-230/l/60 Draft Inducer Speeds 3=200-23013/60 1=Single Speed 4=460/3/60 2=Two Speed r Secondary Function V=Variable Speed Minor Design Modifications Minor Design Change Unit Parts Identifier Service Digit-Not Orderable Air Handlers— 4 T E E 3 F 3 6 A 1 0 0 0 A A Heat Pump/ 2 T X C B 0 3 6 A C 3 H C A A Residential Cooling Coils RefrigerantType RefrigerantType 4=R-410A 2=R-22 4=R-410A 2=R-22 Product Family Application T=Premium(Heat Pump or Convertible Coil) TE=Fully Convertible C=Standard(Cooling Only) TG=Semi Convertible Coil Design TF=Front Return X=Direct Expansion Evaporator Coil TV=Vertical Product Family Product Family C=Cased A Coil E=Leadership-Variable Speed A=Uncased A Coil P=Leadership F=Cased Horizontal Flat Coil C=ReplacemenURetail B=Basic Coil Width(Cased/Uncased) A=14.5'/13.3' C=21.0°/19.8' H=10.5' Flow Control B=17.5'116.3' D=24.5°/23.3' 3= ed TXV FCCV' Refrigerant Line Cou ling 4=FCCVrP 0=Brazed Feature Identifier 0=Standard Unit Nominal Capacity in 000s of BTUs F=Air-TiteTM Major Design Change Nominal Capacity in 000s of BTUs Efficiency Major Design Modifications C=Standard S=Hi Efficiency Power Supply Refrigerant Control 1=Single Phase 3=TXV-Non-Bleed Electrical Connection Coil Circuitry 0=Pig Tails H=Heat Pump B=Circuit Breaker C=Cooling Only D=Pull Disconnect Airflow Configuration Future Option-Factory Installed Heater Nominal KW Value A=Upflow Only Minor Design Modifications U=Upflow/Downflow 9 H=Horizontal Only Unit Parts Identifier C=Convertible-Upflow,Downflow,Left Airflow NOTE:There will be a phase-in of new model numbers for new M=Convertible-Upflow,Downflow,Left or Right Airflow air handlers over next 2 years. Minor Design Change 'Shipped with R-22 FCCV Unit Parts Identifier 6 22-1790-02-2607(EN) TRINE® Electrical Data SCHEMATIC DIAGRAMS (SEE LEGEND) 47TR3018,024,030A1 (: 4TTR:3036,042A042A TO POfER SUPPLY PER UNIT NAMEPLATE ARD LOCAL CODES TO POSER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES n Ir-----J 1---- E -----J L-----a _l START NIT BAYRSNT2G0 zMS-I /--\ MS-2m s MMS-1 I CS I MS-2m y 1CSR-I CSR /�^"�1 CSR- CSR 1 d I -RDr7-v-RAI z s 111BL �I--p�=—Np —6—�1 �eY L. 2.. S: N-BNfBt—I RD CAPACITOR OR CA�(TOR s c - .. D—x �..—..--- Rr•±CCPR' —'c oR DN1RL IUD enONN —I OR eN/RL S'`MTR C H R CPR la _� MTH F C H B I� 111111``"""'""'''"' 11J1111``"�''"'''"' \¥ PURPLE RB ..—..—..____j J `Ii PORPLE RB i LMLACM I `OLACN i 11!THERMALLY NL THERMALLY PROTLCI, PROTECTED INTERMALLY TYPINTEGRALLY I— AIRIXAYDLER I CA TIPITRERHOSTAi q I— 1TIIYICNAGDLER I IYPICALRIgSTAT�� MS HPCO T @ : MS HPCO ELLONIRDiEILOSIRD-0- TFLLOf/BDIELLOS/RD-0- 1 MOSES Iu _ 'RENTER I I I NOTES 112 r ODT-B tOPi IONALI __ _ HEATER IRENOTEI Q COMIDOLS ODT-O o-1T10T 11 N�____ _ fl COMTROLS CHN EN BILf1-r AL___ (R[MOT[I 1 12 _W___r_�__� L — "L' 0- I ODT-A (OPT10RAL) Q ___���__ J ODT•A/TOP TIONALI I I x BM 1 I G --�} --� IELD I N r BN N O I -T -v eDD DDEDUMPER OER OL--OG___ B I I I BL ____t___ B TMs 24 vi I---� I i - rM� M -I Q TO PoNR SUPPLY{��77- i0 POKER SUPPLT I� PER LOCAL CODES ��..—..J I ._—_-J PER LOCAL CODES t�H..__ • . NOTES: NOTES: I. IF ODT-B IS NOT USED, ADD JUMPER BETWEEN W2 d W3 1. IF ODT-B IS NOT USED, ADD JUMPER BETWEEN W2 d W3 AT AIR HANDLER. AT AIR HANDLER. IF USED, DDT•B MUST BE MOUNTED REMOTE OF CONTROL IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT.A IS NOT USED, ADD JUMPER BETWEEN WI d W2 2. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN WI d W2 AT AIR HANDLER. AT AIR HANDLER. 3. LOW VOLTAGE (24 V.) FIELD WIRING MUST BE 18 AWG MIN. 3. LOW VOLTAGE (24 V.) FIELD WIRING MUST HE 18 AWG MIN. ©WARNING ©CAUTION ©WARNING A CAUTION HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF BEFORE SERVICING. CONDUCTORS. BEFORE SERVICING. CONDUCTORS. FAILURE TO DISCONNECT POWER FAILURE TO DO SO MAY CAUSE FAILURE TO DISCONNECT POWER FAILURE TO DO SO MAY CAUSE BEFORE SERVICING CAN CAUSE DAMAGE TO THE EQUIPMENT! BEFORE SERVICING CAN CAUSE DAMAGE TO THE EOUIPMENTI SEVERE PERSONAL INJURY OR DEATH, SEVERE PERSONAL INJURY OR DEATH! FOR CANADIAN INSTALLATIONS FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ONCAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND. SYSTEMS EXCEEDING 150V-TO-GROUND. ATTENTION: NE CONVIENT PAS AUX ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A INSTALLATIONS DE PLUS DE 150 V A LA TERRE. LA TERRE. PRINTED FROM D154861 POI REV00 PRINTED FROM D154862POI REV00 22-1790-02-2607(EN) 7 Electrical Data SCHEMATIC DIAGRAMS (SEE LEGEND) 4TTR3048A1 4TTR3060131 TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES TO POWER SUPPLY PER UNIT NAMEPLATE ADD LOCAL CODES F f-----J L------ I r----- SUMP HTR E I —.. IDL START KIT I L BLACK-+O�f/VV+—BLACK�PURPLEIWN—O-�F—POAPLC/WH J r m _ BAYHSNT280 � s --Z�-J aM5 I CS MS-2M s 6MS-1 CS MS 2m CSR-I CSR I / CSR-! CSR 1 l b I�6—%ARD % f -BR 1 t S: %—OX/Bl—% � ADCSBR I 2 5 BR/8L I v RD _ _ OR _ _ _ CANTOR DR %— — - C FS -t I ' C L7 D�BROWR� OA BX IBL D`BRORN OR B%IBL FAN 1 L` C H CPR la JI AF7TR J CF R CPR IOL -- — �WE L–PURPLE�RD RD J 'O �C�M!R PURPLE RD +IL THERMALLY J H!P THERMALLY i PROTCCIt I PROTECTED C INTERNALLY I IH7ERNALLT HI-TEMP HI-TEMP HPCO S1. HPCO SW. LPCO TIDIGL TTPICAL NEAT/COOL TYPICAL TYPICAL NEAP/COOL I— AIR HANDLER I I-THERMOSTAT I W I— AIR HANDLER I-THERMOSTAT I NOTES I92 - NOTES I92 – ODi-W ItN[IOOiC l f"– [OWTRO 51 I I I r ODT-8 IOPi IONAL I : }- CONTROeS 12 –_ (REMOTE) ----I UK L - BN i % Ir 11 – 11 ODT-A IODT IONALJ J 1 I ODT-A (OPTIORALI I – C1—x—Bx—% ' rO�C1—x—BR % MELD I O I I w�ED I MELD ADDED Q I I JUMPER W ULA--_–I IRS R TO POWER SUPPLY PER LOCAL CODES l Zb..—.-J I—.-__-_J TO POWER SUPPLY __ NOTES: NOTES: PER LOCAL CODES ----t=:O -_..J I_.._..J I. IF ODT-B IS NOT USED, ADD JUMPER BETWEEN W2 d W3 1. IF ODT-8 IS NOT USED,ADD JUMPER BETWEEN W2 S W3 AT AIR HANDLER- AT AIR HANDLER. IF USED,0111-11 MUST BE HUNTED REMOTE OF CONTROL IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL 801 IN AN APPROVED WEATHER PROOF ENCLOSURE. BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. z. IF 0DT-A IS NOT USED,ADD JUMPER BETWEEN WI a W2 AT AIR 2. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN WI 8 W2 3. LON VOLTAGEL HANDER.24 V.)FIELD WIRING MUST BE 18 AWG HIM. AT AIR HANDLER. 3. LOW VOLTAGE 124 V.) FIELD WIRING MUST BE 18 AWG MIN. AVARNING 0 CAUTION HAZARDOUS VOLTAGE) USE COPPER CONDUCTORS ONLYI ©WARNING © CAUTION DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED INCLUDING RCM07E DISCONNECTS i0 ACCEPT OTHER TYPES Of HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! BEFORE SERVICING. CONDUCTORS. DISCONNECT ALL ELECTRIC POWER UNIT TERMINALS ARE NOT DESIGNED FAILURE TO DISCONNECT POWER FAILURE TO Do SO MAY CAUSE INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF: BEFORE SERVICING CAN CAUSE DAMAGE TO THE EOUIPMENTI BEFORE SERVICING. CONDUCTORS. SEVERE PERSONAL INJURY OR DEATH! FAILURE To DISCONNECT POWER FAILURE TO DO SO MAY CAUSE BEFORE SERVICING CAN CAUSE DAMAGE TO THE EOUIPMENTI FOR CANADIAN INSTALLATIONS SEVERE PERSONAL INJURY OR DEATH! POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON FOR CANADIAN INSTALLATIONS SYSTEMS EXCEEDING ISOV-TO-GROUND. POUR INSTALLATIONS CANADIENNES ATTENTION: NE CONVIENT PAS AUX 7LATERRE. ON: NOT SUITABLE FOR USE ON INSTALLATIONS DE PLUS DE 150 V A MS EXCEEDING 150V-TO-GROUND. TION: NE CONVIENT PAS AUX LLATIONS DE PLUS DE 150 V A PRINTED FROM D154863POI REV00 PRINTED FROM D155205POl REV00 8 22-1790-02-2607(EN) TANME® Electrical Data SCHEMATIC DIAGRAMS LEGEND COLOR OF WIRE BK/BL BLACK WIRE WITH BLUE MARKER 'L-COLOR OF MARKER BK BLACK OR ORANGE YL YELLOW BL BLUE RD RED GR GREEN BR BROWN WH WHITE PR PURPLE SYMBOLS 24 V. FACTORY WIRING LINE V. - - - 24 V. FIELD WIRING LINE V. —X— FIELD INSTALLED FACTORY WIRING GROUND ® JUNCTION Q WIRE NUT OR CONNECTOR COIL -��- CAPACITOR --�F- RELAY CONTACT (N.0. ) RELAY CONTACT (N.C. ) THERMISTOR T 6a INTERNAL OVERLOAD PROTECTOR PRESSURE ACTUATED SWITCH TEMP. ACTUATED SWITCH 2 3 POL. PLUG FEMALE HOUSING W W W (MALE TERM. ) Y Y Y POL. PLUG MALE HOUSING I 2 s (FEMALE TERM. ) -/\/\/` RESISTOR OR HEATING ELEMENT 0----o MOTOR WINDING 0 TERMINAL CA COOLING ANTICIPATOR LPCO LOW PRESSURE CUTOUT SW. CBS COIL BOTTOM SENSOR MS COMPRESSOR MOTOR CONTACTOR CF FAN CAPACITOR ODA OUTDOOR ANTICIPATOR CN WIRE CONNECTOR OFT OUTDOOR FAN THERMOSTAT CPR COMPRESSOR ODS OUTDOOR TEMPERATURE SENSOR CR RUN CAPACITOR ODT OUTDOOR THERMOSTAT CS STARTING CAPACITOR RHS RESISTANCE HEAT SWITCH CSR CAPACITOR SWITCHING RELAY SC SWITCHOVER VALVE SOLENOID DFC DEFROST CONTROL SM SYSTEM "ON-OFF" SWITCH F INDOOR FAN RELAY TDL DISCHARGE LINE THERMOSTAT HA HEATING ANTICIPATOR TNS TRANSFORMER HPCO HIGH PRESSURE CUTOUT SW. TS HEATING-COOLING THERMOSTAT IOL INTERNAL OVERLOAD PROTECTOR TSH HEATING THERMOSTAT 22-1790-02-2607(EN) 9 TAWE® Dimensions 4TTR3 OUTLINE DRAWING NOTE:ALL DIMENSIONS ARE IN MM(INCHES) B C SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES d PER PREVAILING CODES. il i TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 IS FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT. AND SHOULD BE AT LEAST 305 (12') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. K ELECTRICAL SERVICE PANEL 25 111 A 22.2 (718) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. H.O. WIT 22.2 (718) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, 'E' I. 4-1 D. FEMALE BRAZE CONNECTION WITH I/4' SAE H FLARE PRESSURE TAP FITTINGS. F FlG. 1 J .0. FOR ALTERNATE ELECTRICAL ROUTING G AS LINE 1/4 TURN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTING, r MODELS BASE FIG. A B C D E F G H J K 4TTR3018A 3 1 832(32-3/4) 829(32-5/8) 756(29-3/4) 1/2 1/4 143(5-5/8) 92(3-5/8) 210(8-1/4) 79(3-1/8) 508(20) 4TTR3024A 3 1 832(32-3/4) 829(32-5/8) 756(29-3/4) 5/8 5/16 143(6-5/8) 92(3-5/8) 210(8-1/4) 79(3-1/8) 508(20) al 41TR3030 3 1 832(32,V4) 829(32-5/8) 756(29-3/4) 3/4 5/16 143(5-5/8) 92(3-5/8) 210(8-1/4) 79(3-1/8) 508(20) p 36A 3 1 933(36-3/4) 829(32-5/8) 756(29-3/4) 3/4 3/8 143(5-5/8) 92(3-5/8) 210(8-1/4) 79(3-1/8) 508(20) N cz 1 2A 4 1 841(33-1/8) 946(37-1/4) 870(341/4) 3/4 3/8 152(6) 98(3-718) 219(8-5/8) 86(3-3/8) 508(20) a 4TTR3048A 4 1 841 (33-1/8) 946(37-1/4) 870(341/4) 7/8 3/8 152(6) 96(3-7/8) 219(8-518) 86(3-3/8) 508(20) E 4TTR3060B 4 1 1045 41-1/8 948 37-1/4 870 341/4 7/8 1 3/8 152.6 98(3-7/8) 219 8-5/8 86(3-3/8) 508 20 LL 10 22-1790-02-2607(EN) TRAME® Mechanical Specification Options General Condenser Coil The 4TTR3 shall be fully charged from The Spine FinTM coil shall be continu- the factory for matched indoor section ously wrapped,corrosion resistant all and up to 15 feet of piping.This unit must aluminum with minimum brazed joints. be designed to operate at outdoor This coil is 3/8 inch O.D.seamless ambient temperatures as high as 11 FF. aluminum glued to a continuous alumi- Cooling capacities shall be matched with num fin.Coils are lab tested to withstand a wide selection of air handlers and 2,000 pounds of pressure per square furnace coils that are ARI certified.The inch.The outdoor coil provides low unit shall be UL listed.Exterior must be airflow resistance and efficient heat designed for outdoor application. transfer.The coil is protected on all four Casing sides by louvered panels and has a Unit casing is constructed of heavy 10 year limited warranty. gauge,galvanized steel and painted with Low Ambient Cooling a weather-resistant powder paint. As manufactured,this unit has a cooling Corrosion and weatherproof CMBP-G30 capability to 55°F.The addition of an DuraTuffTm base. evaporator defrost control permits Refrigerant Controls operation to 30°F.The addition of a low Refrigeration system controls include ambient kit with TXV permits low ambient condenser fan and compressor cooling to 0°F. contactor.High and low pressure controls Accessories are inherent to the compressor.Another Thermostats—Heating/Cooling standard feature is the liquid line dryer. (manual and automatic changeover). Compressor Sub-base to match thermostat and The Climatuff®compressor features locking thermostat cover. internal over temperature and pressure Evaporator Defrost Control—See Low protector,total dipped hermetic motor Ambient Cooling. and thermostatically controlled sump Outdoor Thermostat—Supplemental heater.Other features include:roto lock heat outdoor ambient lockout from suction and discharge refrigeration 46 to–10°F. connections,centrifugal oil pump,and low vibration and noise.The ClimatuffO compressor is standard with a 10 year limited warranty. 22-1790.02-2607(EN) 11 IU C U@ L US TM ARI Standard 210/240 UAC P.I. TRME® Trane Abuslnessof American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change www.VRW.Com design and specifications without notice. TRAAFE LzI, 4TEC3F24B1OOOA 14,10TRE-5073 3�6RIJ-0,00fi3 4TEC3F42C1OOOA 4TEC3F48B1OOOA 4TEC3F60B1OOOA 2 — 5 Ton IiUlllllllll no PUB. NO. 22-1774-18 7XWF® Features and Benefits 13.0 SEER ° Superior condensate performance • Low voltage wire nut connections • Ships vertical — converts to hori- a Factory installed non-bleed TXV • Insulated cabinet zontal by laying unit on its side. ° Easy Air-TiteTM access to coil • Uses 1400 series heaters • Six-way convertibility – horizontal © Meets or exceeds Florida 2% leak- • External access to heater circuit (left & right), front and rear access; age criteria breakers upflow, downflow Enhanced internally finned coil a Polarized plugs for making electri- • "1-man"installation opportunity tubes cal connections from air handler Electrical, refrigerant, condensate . Multi-speed, Direct drive motor control box to heaters & blower access convertible to ei- • Approved for modular or manufac- ther side Versatile duct flange - allows flush fit.3/4", 1" or 1.5"duct insulation tured homes Compact 21" depth for easy instal- lation ° Filter panel stamped with word "fil- ter" • Corrosion resistant galvanized met- al with attractive finish ° 200/230 volt primary & 24 volt sec- ondary transformer Selecti®n Procedure Model Number Nomenclature 1 2 3 4 5 6 7 3 9 10 11 12-13 14 15 4 T E C 3 F 2 4 B 1 0 00 A A SYSTEM TYP 2=R-22 4=R-410 APPLICATION TE =Fully Convertible UNIT PARTS TG =Semi Convertible IDENTIFIER TF=Front Return TV =Vertical MINOR DESIGN PRODUCT FAMILY MODIFICATION E=Leadership-Variable Speed FUTURE'OPTION-Factory P=Leadership C=Replacement/Retail Inst Nominal Valueeater KW Value B=Basic FLOW CONTROL ELECTRICAL CONNECTION 0 = Pig Tails 3 = Non-Bleed TXV B=Circuit Breaker 4 = FCCV D=Pull Disconnect FEATURE IDENTIFIER 0 =Standard Unit POWER SUPPLY F =Air-Tite 1=Single Phase NOMINAL NET COOLING CAPACITY(MBTUH) MAJOR DESIGN MODIFICATION ©2012 Trane 2 22-1774-18 7RWE® Contents Features and Benefits 2 Selection Procedure - 2 Model Number Nomenclature 2 General Data 4 4TEC3F24131000A 4 4TEC3F3661000A 4 4TEC3F42C1000A 4 4TEC3F4861000A 4 4TEC3F60131000A 4 Performance Data 6 Electrical Data 12 Field Wiring is 4TEC3F24-60B Convertibility 2® Dimensions 21 Mechanical Specification Options 22 22-1774-18 3 7E® General Data MODEL 4TEC31F24131000A 4TEC3F36B1000A 4TEC3F42C1000A RATED VOLTS/PH/HZ. 208-230/1/60 200-230/1/60 200-230/1/60 RATINGS O See O.D.Specifications See O.D.Specifications See O.D.Specifications INDOOR COIL—Type Plate Fin Plate Fin Plate Fn Rows—F.P.I. 3-14 3-14.0 3-14 Face Area(sq.ft.) 3.21 3.67 5.04 Tube Size(in.) 3/8-Copper 3/8-Copper 3/8-Copper Refrigerant Control TXV-NB TXV-NB TXV-NB Drain Conn.Size(in.)O 3/4 NPT 3/4 NPT 3/4 NPT INDOOR FAN—Type Centrifugal Centrifugal Centrifugal Diameter-Width(in.) 9 X 8 10 x 7 10 x 10 No.Used 1 1 1 Drive-No.Speeds Direct-3 Direct-3 Direct-4 CFM vs.in w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table No.Motors—H.P. 1-1/3 1—1/3 1-1/2 Motor Speed R.P.M. 1075 1080 1075 Volts/Ph/Hz 200-230/1/60 200-230/1/60 200-230/1/60 F.L.Amps-L.R.Amps 1.55-2.6 2.2-5.3 3.3-6.9 FILTER Vertical Applications Filter Furnished? Yes Yes Yes Type Recommended Throwaway Throwaway Throwaway No.-Size-Thickness 1-20 X 20 x 1 in. 1-20 x 20 x 1 in. 1-20 x 20 x 1 in. Horizontal Applications Filter Furnished? No No No Recommended Size O See Note O See Note® See Note O REFRIGERANT R-41 OA R-410A R-41 OA Ref.Line Connections Brazed Brazed Brazed Coupling or Conn.Size—in.Gas 5/8 3/4 3/4 Coupling or Conn.Size—in Liq. 5/16 3/8 3/8 DIMENSIONS HxWxD HxWxD HxWxD Crated(in.) 44 1/2 x 24 x 23-1/2 46-1/2 x 24 x 23-1/2 53-1/4 x 26 x 23-1/2 Uncrated See Outline Drawing See Outline Drawing See Outline Drawing WEIGHT Shipping(Lbs.)/Net(Lbs.) 121/111 135/125 165/150 MODEL 4TEC3F48B1000A 4TEC3F60B10001 OO These Air Handlers are A.R.I. RATED VOLTS/PH/HZ. 200-230/1/60 200-230/1/60 certified with various Split System RATINGS O See O.D.Specifications See O.D. Air Conditioners and Heat Pumps PSpecifications— (ARI STANDARD 210/240). Refer to INDOOR COIL—Type Plate Fin Plate Fin the Split System Outdoor Unit Product Rows—F.P.I. 3-14(3-16,4TEC) 3—14(3-16,4TEC) Data Guides for performance data. Face Area(sq.ft.) 6.19 6.19 03/4"Male Plastic Pipe(Ref.: ASTM 1785- Tube Size(in.) 3/8-Copper 3/8-Copper 76) Refrigerant Control TXV-NB TXV-NB @ Minimum fitter size for horizontal applica- Drain Conn.Size(in.)0 3/4 NPT 3/4 NPT tions will be based on airflow,selection INDOOR FAN—Type Centrifugal Centrifugal and will be calculated as follows: Diameter-Width(in.) 11 x 10 11 x 10 Low Velocity Filter: No.Used 1 1 Face area(Sq.Ft.) = CFM/300 Drive-No.Speeds Direct-3 Direct-4 High velocity Filter: CFM vs.in w.g. See Fan Performance Table See Fan Performance Table Face area(Sq.Ft.) =CFM/500 No.Motors—H.P. 1-1/2 1—1 Motor Speed R.P.M. 1000 1050 Volts/Ph/Hz 200-230/1/60 200-230/1/60 F.L.Amps-L.R.Amps 2.7-4.5 7.6 FILTER Vertical Applications Filter Furnished? Yes Yes C lis Type Recommended Throwaway Throwaway «arEv No.-Size-Thickness 1-20 x 20 x 1 in. 1-20 x 22 x 1 in. Horizontal Applications Intertek Filter Furnished? No No Recommended Size(D See Note O See Note O REFRIGERANT R-41 OA R-410A Ref.Line Connections Brazed Brazed Coupling or Conn.Size—in.Gas 7/8 7/8 Coupling or Conn.Size—in Liq. 3/8 3/8 DIMENSIONS HxWxD HxWxD Crated(in.) 53-1/2 x 26 x 23-1/2 59-1/2 x 26 x 23-1/2 Uncrated See Outline Drawing See Outline Drawing WEIGHT Shipping(Lbs.)/Net(Lbs.) 166/151 170/155 4 22-1774-18 General Data PRESSURE DROP FOR ELECTRIC HEATERS IN AIR HANDLER MODELS HEATER RACKSNUMBER OF RACKS 1 2 T 3 1 4 1 5 HEATER NO.OF AIRFLOW AIR PRESSURE DROP MODEL NO. RACKS CFM INCHES W.G. 600 0.01 0.02 0.02 BAYHTR1405 1 700 0.01 0.02 0.02 - BAYHTR1408 2 800 0.02 0.03 0.03 0.04 900 0.03 0.03 0.04 0.05 BAYHTR1410 2 1000 0.04 0.04 0.05 0.06 1100 0.04 0.05 0.06 0.07 1 0.08 BAYHTR3410 2 1200 0.05 0.06 0.07 0.08 0.09 1300 0.06 0.07 0.08 0.09 0.11 BAYHTR1415 3 1400 0.07 0.08 0.10 0.11 0.13 1500 0.08 0.09 0.11 0.13 0.15 BAYHTR3415 3 1600 0.09 0.10 0.12 0.15 0.17 BAYHTR1419 4 1700 0.10 0.11 0.14 0.17 0.19 1800 0.11 0.13 0.16 0.19 0.21 BAYHTR1425 5 1900 0.13 0.15 0.18 0.21 0.23 2000 0.14 0.17 0.20 0.23 0.26 NOTES: 1.See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters 2.Heater model numbers may have additional suffix digits. 22-1774-18 5 Performance Data Airflow Performance 4TEC3F24B:Wet coil, No Heaters AIRFLOW(CFM) EXTERNAL VERTICAL HORIZONTAL STATIC PRESSURE (in.w.g.) 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED LO HI MED LO HI MED LO HI MED LO 0 1134 876 818 1093 781 723 1083 870 813 1050 780 739 0.1 1102 839 789 1073 751 696 1051 831 783 1020 745 697 0.2 1048 798 751 1020 713 661 996 783 739 967 703 657 0.3 984 750 705 953 668 618 930 728 687 903 655 614 0.4 912 694 649 880 614 567 858 667 628 833 600 563 0.5 833 622 581 802 548 504 782 597 561 758 533 499 0.6 738 532 496 714 465 425 693 512 479 669 452 417 0.7 614 416 385 599 358 321 579 406 375 554 349 313 0.8 442 268 240 434 216 184 418 266 236 391 217 182 0.9 197 - - j 187 - - 184 - 156 - - With filter,no horizontal drip tray NOTES: Small apex baffle As shipped except without filter Subtract 0.06"W.G.for downflow Subtract 0.05""W.G.for horizontal left 6 22-1774-18 Performance Data Airflow Performance 4TEC3F36B:Wet coil,No Heaters EXTERNAL AIRFLOW(CFM) STATIC PRESSURE (in.w.g.) VERTICAL HORIZONTAL 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED LO HI MED LO HI MED LO HI MED LO 0 1484 1282 1077 1402 1200 963 1402 1265 1069 1349 1165 947 0.1 1412 1268 1082 1352 1166 948 1350 1228 1048 1298 1131 915 0.2 1344 1226 1055 1292 1130 924 1289 1180 1015 1243 1090 890 0.3 1277 1171 1013 1227 1089 893 1225 1127 976 1185 1047 866 0.4 1209 1110 965 1163 1040 856 1163 1073 933 1127 1001 836 0.5 1139 1049 915 1098 982 814 1104 1019 887 1066 953 795 0.6 1065 987 862 1031 915 764 1043 962 835 1001 898 743 0.7 988 916 799 957 839 703 977 897 771 929 829 677 0.8 907 827 713 870 757 624 894 815 689 846 736 599 0.9 823 702 584 760 671 521 783 707 579 745 609 513 NOTES: With filter,no horizontal drip tray As shipped except without filter Small apex baffle Subtract 0.05""W.G.for horizontal left Subtract 0.06"W.G.for downflow 22-1774-18 7 rA4ME® Performance Data Airflow Performance 4TEC3F42C:Wet coil, No Heaters EXTERNAL AIRFLOW(CFM) STATIC PRESSURE VERTICAL HORIZONTAL (in.w.g.) 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED LO HI MED LO HI MED LO HI MED LO 0 1869 1690 1435 1723 1435 1100 1793 1533 1309 1721 1400 1100 0.1 1715 1542 1316 1640 ' 1367 1079 1721 1522 1277 1665 1389 1095 0.2 1609 1449 1237 1561 1317 1060 1651 1471 1237 1600 1350 1068 0.3 1529 1380 1177 1485 1274 1032 1578 1400 1190 1527 1294 1030 0.4 1458 1314 1123 1409 1227 991 1500 1322 1139 1449 1231 987 0.5 1385 1240 1064 1332 1170 939 1417 1245 1085 1367 1164 940 0.6 1303 1158 1000 1251 1099 884 1329 1170 1026 1284 1094 889 0.7 1210 1078 932 1165 1015 838 1237 1092 963 1200 1019 826 0.8 1109 1018 870 1071 921 820 1145 1000 895 1117 931 740 0.9 1009 1010 829 968 825 854 1057 878 819 1034 820 617 NOTES: With filter,no horizontal drip tray As shipped except without filter Small apex baffle Subtract 0.05""W.G.for horizontal left Subtract 0.06""W.G.for downflow 8 22-1774-18 Performance Data Airflow Performance 4TEC3F48B:Wet coil, No Heaters AIRFLOW(CFM) EXTERNAL VERTICAL HORIZONTAL STATIC PRESSURE 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI I MED LO HI MED LO HI MED LO HI MED LO 0 1945 1768 1617 1810 1618 1478 1959 1745 1582 1768 1562 1440 0.1 1880 1712 1583 1762 1574 1428 1910 1722 1612 j 1750 1606 1430 0.2 1824 1659 1532 1710 j 1526 1382 1860 1683 1582 1714 1577 1390 0.3 1770 1606 1474 1654 1476 1333 1810 1636 1524 1664 1511 1336 0.4 1712 1551 1415 1595 1421 1278 1758 1584 1457 1606 1436 1275 0.5 1647 1490 1358 1532 1360 1212 1700 1529 1394 1542 1365 1213 0.6 1571 j 1419 1296 1462 1290 1134 1636 1470 1336 1471 1300 1146 0.7 1485 1337 1219 1383 1206 1044 1561 1402 1274 1392 1228 1068 0.8 1391 1238 1113 1291 1101 945 1471 1319 1190 1300 1127 966 0.9 1293 1120 955 1180 970 840 1363 1212 1056 1190- 959 1 821 NOTES: With filter, no horizontal drip tray As shipped except without filter Small apex baffle Subtract 0.05""W.G.for horizontal left Subtract 0.06""'W.G.for downflow 22-177418 9 7RWE® Performance Data Airflow Performance 4TEC3F60B:Wet coil,No Heaters EXTERNAL AIRFLOW(CFM) STATIC PRESSURE VERTICAL HORIZONTAL 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS HI MED-H M-LO Low HI MED-H M-LO Low HI MED-H M-LO Low HI MED-H M-LO Low 0 2163 2018 1901 1831 2129 1988 1893 1820 2107 1963 1840 1774 2085 1956 1837 1777 0.1 2132 1974 1852 1796 2091 1954 1833 1769 2063 1927 1810 1743 2049 1912 1797 1729 0.2 2088 1936 1811 1754 2049 1915 1790 1722 2028 1889 1773 1706 2011 1870 1756 1683 0.3 2044 1901 1775 1709 2008 1874 1756 1678 1995 1851 1735 1663 1973 1830 1716 1638 0.4 2004 1867 1741 1663 1970 1835 1723 1634 1962 1814 1698 1617 1934 1793 1678 1593 0.5 1972 1832 1707 1617 1935 1797 1687 1590 1925 1778 1662 1569 1896 1757 1641 1548 0.6 1941 1797 1672 1572 1899 1761 1646 1542 1883 1743 1628 1520 1855 1721 1606 1501 0.7 1902 1760 1635 1526 1858 1725 1602 1489 1834 1710 1595 1473 1812 1685 1570 1450 0.8 1841 1721 1594 1475 1803 1684 1556 1427 1779 1678 1559 1429 1761 1648 1531 1392 0.9 1735 1683 1 1549 1416 1722 1636 1516 1354 1719 1648 1518 1389 1699 1606 1484 1326 NOTES: With filter,no horizontal drip tray As shipped except without filter Small apex baffle Subtract 0.05"W.G.for horizontal left Subtract 0.06"W.G.for downflow 10 22-1774-18 77MM" Performance Data Air Handier/Fan Speed Heater Matrix HEATER MODEL NUMBER EAYHTR Air Handler Unit 1405 1408 *410 *415 1419 1425 *=1 or 3 Model Position Application 4.80KW 7.68Kw 9.60Kw 15.36KW 19.20KW 24.96KW Vertical A/C or Elec.Furnace L L L L — — UpflowHeat Pum L L L M — — Vertical or ec.Furnace L L L L — — 4TEC3F24B Downflow Heat PL L L M — — Horizontal or Me..Furnace L L L L — — Left Heat Pump L L L M — — Horizontal or Elec.Furnace— L L L — — Right Heat Pump L L L M — — Vertical A/C or Elec.Furnace L L L L L — Upflow Heat Pump L L L H — Vertical or Elec.Furnace L L L L L — 4TEC3F36B Downflow Heat Pump — Horizontal or bec.Furnace L L L L L — Lefteat Pum L — Horizontal or ec.Furnace L F L L L — Right Heat Pump L L L H H — Vertical A/C or Elec.Furnace ML ML ML ML ML — Upflow eat um — Vertical or ec.Furnace ML ML ML ML ML ML 4TEC3F42C Downflow Heat Pump WE MML ML H — Horizontal or Elec.Furnace ME ML ML ML ML — LeftHeat Pum ML ML ML H H — Horizontal or ec.Furnace ML — Right Heat Pump ML IVIL ML H H — Vertical A/C or Elec.Furnace L L L L L — Upflow Heat Pump L L L M — Vertical or Elec.Furnace — 4TEC3F488 Downfloweat um — Horizontal or ec.F u r n a c e L L L L L — Left FFeat Pump L L L L L — Horizontal or Elec.Furnace L L L L L — Right Heat Pump L L L L L — Vertical A/C or Elec.Furnace L L L L L — UpflowHeat Pum L L L L ML — Vertical or ec. urnace L L L — 4TEC3F606 DownflowHeat Pum L L M M — Horizontal or Pec.Furnace LL L — Left Heat Pump L L L ML M — Horizontal C or Elec.Furnace L L L L L — Right Heat Pump L L L ML L — 22-1774-18 11 Electrical TAWF11 Data 4TEC3F24B WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Num- 240 VOLT 208 VOLT Heater ber of Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Model No. Circuits/ Amps per Circuit Overload Amps per Circuit Overload Phase KW BTUH Circuit Ampacity Protection KW BTUH Circuit Ampacity Protection NONE 1/1 N/A N/A N/A 2 15 N/A I N/A N/A 2 15 BAYHTR1405+++ 1/1 4.80 16400 20 27 30 3.60 12300 17.3 24 25 BAYHTR1408+++ 1/1 7.68 26200 32 42 45 5.76 19700 27.7 37 40 BAYHTR1410+++ 1/1 9.60 32800 40 52 60 7.20 24600 34.6 45 45 BAYHTR3410 000 1/3 9.60 32800 34.6 43 45 7.20 24600 30 37 40 BAYHTR1415 BRK 2/1 15.36 52400 40/24 52*/30 60*/30 11.53 39300 34.6/20.8 45*/26 45*/30 BAYHTR1415 BRK with Single Circuit 1/1 15.36 52400 64 90 90 11.53 39300 55.4 79 80 Power Source Kit BAYSPEK140B BAYHTR3415 000 1/3 15.36 52400 39.5 49 50 11.53 39300 34.4 43 45 NOTES: 'Circuit 1/Circuit 2(Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amps) +++=000,BRK,PDC 000=pigtails,BRK=contains circuit breakers,PDC=contains pull disconnect IMPORTANT:Any power supply and/or combination power supply,circuit or circuits must be wired and protected in accordance with local Electrical Codes. 4TEC3F36B WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) Number 240 VOLT 208 VOLT Heater of Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Model No. Circuits/ Amps per Circuit Overload Amps per Circuit Overload Phase KW BTUH Circuit Ampacity Protection KW BTUH Circuit Ampacity Protection NONE 1/1 N/A N/A N/A 3 15 N/A N/A N/A 3 15 BAYHTR1405+++ 1/1 4.80 16400 20 28 30 3.60 12300 17.3 24 25 BAYHTR1408+++ 1/1 7.68 26200 32 43 45 5.76 19700 27.7 37 40 BAYHTR1410+++ 1/1 9.60 32800 40 53 60 7.20 24600 34.6 46 50 BAYHTR3410 000 1/3 9.60 32800 34.6 43 45 7.20 24600 30 37 40 BAYHTR1415 BRK 2/1 15.36 52400 40/24 53*/30 60*/30 11.53 39300 34.6/20.8 46*/26 50*/30 BAYHTR1415 BRK with Single Circuit 1/1 15.36 52400 64 90 90 11.53 39300 55.4 79 80 Power Source Kit BAYSPEK140B BAYHTR3415 000 1/3 15.36 52400 40 50 50 11.53 39300 34.9 44 45 BAYHTR1419 BRK 2/1 19.20 65500 32/48 43*/60 45*/60 14.42 49200 27.7/41.6 37*/52 40*/60 BAYHTR1419 BRK with Single Circuit 1/1 19.2 65500 80 110 110 14,42 49200 69.3 96 100 Power Source Kit BAYSPEK140B NOTES: 'Circuit 1/Circuit 2(Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amps) ...=000,BRK,PDC 000=pigtails,BRK=contains circuit breakers,PDC=contains pull disconnect IMPORTANT:An 2ower suRply and/or combination power supply,circuit or circuits must be wired and Rrotected in accordance with local Electrical Codes. 12 22-1774-18 Electrical Data 7NMEO 4TEC3F42C WIRING DATA (Indoor Blower Motor Powered from Heater Circuit 1) 240 VOLT 208 VOLT Heater Number of Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Model No. phase Amps per Circuit Overload Amps per Circuit Overload KW BTUH Circuit Ampacity Protection KW BTUH Circuit Ampacity Protection NONE 1/1 WA N/A N/A 4.1 15 N/A I N/A N/A 4.1 15 BAYHTR1405+++ 1/1 4.80 16400 20 29 30 3.60 12300 17.3 26 30 BAYHTR1408+++ 1/1 7.68 26200 32 44 45 5.76 19700 27.7 39 40 BAYHTR1410+++ 1/1 9.60 32800 40 54 60 7.20 24600 34.6 47 50 BAYHTR3410 000 1/3 9.60 32800 34.6 43 45 7.20 24600 30 37 40 BAYHTR1415 BRK 2/1 15.36 52400 40/24 53*/30 60*/30 11.531 39300 34.6/20.8 47*/26 50*/30 BAYHTR1415 BRK with Single Circuit 1/1 15.36 52400 64 90 90 11.53 39300 55.4 79 80 Power Source Kit BAYSPEK140B BAYHTR3415 000 1/3 15.36 52400 41 51 60 11.53 39300 35.9 45 45 BAYHTR1419 BRK 2/1 19.20 65500 32/48 44*/60 45*/60 14.42 49200 27.7/41.6 39*/52 40*/60 BAYHTR1419 BRK with Single Circuit 1/1 19.2 65500 80 110 110 14.42 49200 69.3 96 100 Power Source Kit BAYSPEK140B NOTES: *Circuit 1/Circuit 2(Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amps) ++1=000,BRK,PDC 000=pigtails,BRK=contains circuit breakers,PDC=contains pull disconnect IMPORTANT:Any power supply and/or combination power supply,circuit or circuits must be wired and protected in accordance with local Electrical Codes. 4TEC3F48B WIRING DATA (Indoor Blower Motor Powered from Heater Circuit*) 240 VOLT 208 VOLT Number Capacity Maxi- Capacity Heater of Heater Minimum mum Heater Minimum Maximum Model No. Circuits/ Amps Circuit Overload Amps per Circuit Overload PhaseKt� BTUH Circuit Ampacity Protec- KW BTUH Circuit Ampacity Protection tion NONE 1/1 N/A N/A N/A 3.4 15 N/A N/A N/A 3.4 15 BAYHTR1405+++ 1/1 4.80 16400 20 28 30 3.60 12300 17.3 25 25 BAYHTR1408+++ 1/1 7.68 26200 32 43 45 5.76 19700 27.7 38 40 BAYHTR1410+++ 1/1 9.60 32800 40 53 60 7.20 24600 34.6 47 50 BAYHTR1415 BRK 2/1 15.36 52400 40/24 53*/30 60*/30 11.53 39300 34.6/20.8 47*/26 50'/30 BAYHTR1415 BRK with Single Circuit 1/1 15.36 52400 64 90 90 11.53 39300 55.4 79 80 Power Source Kit BAYSPEK140B BAYHTR3410 000 1/3 9.60 32800 34.6 43 45 7.20 24600 30.0 37 40 BAYHTR3415 000 1/3 15.36 52400 38.2 51 60 11.53 39300 33.1 44 45 BAYHTR1419 BRK 2/1 19.20 65500 32/48 43*/60 45*/60 14.42 49200 27.7/41.6 38*/52 40*/60 BAYHTR1419 BRK with Single Circuit 1/1 19.2 65500 80 110 110 14.42 49200 69.3 96 100 Power Source Kit BAYSPEK140B NOTES: 'Circuit 1/Circuit 2(Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amps) +++=000,BRK,PDC 000=pigtails,BRK=contains circuit breakers,PDC=contains pull disconnect IMPORTANT:Any power supply and/or combination power supply,circuit or circuits must be wired and protected in accordance with local Electrical Codes. 22-1774-18 13 Electrical Data 4TEC3F60B WIRING DATA (Indoor Blower Motor Powered from Heater Circuit*) Num- 240 VOLT 208 VOLT Maximum Model No. Cir- Heater ber of Capacity Heater Minimum Maximum Capacity Heater Minimum Overload cuits/ Amps per Circuit Overload Amps per Circuit protection Phase KW BTUH Circuit Ampacity Protection KW BTUH Circuit Ampacity NONE 1/1 N/A N/A N/A 9.5 15 N/A N/A NIA 9.5 15 BAYHTR1405+++ 1/1 4.80 16400 20 35 35 3.60 12300 17.3 31 35 BAYHTR1408+++ 1/1 7.68 26200 32 50 50 5.76 19700 27.7 44 45 BAYHTR1410+++ 1/1 9.60 32800 40 60 60 1 7.20 24600 34.6 53 60 BAYHTR1415 BRK 2/1 15.36 52400 40/24 60*/30 60*/30 11.53 39300 34.6/20.8 53*/26 60*/30 BAYHTR1415 BRK with Single Circuit 1/1 15.36 52400 64 90 90 11.53 39300 55.4 79 80 Power Source Kit BAYSPEK140B BAYHTR3410 000 1/3 9.60 32800 34.6 43 45 7.20 246061 30.0 37 40 BAYHTR3415 000 1/3 15.36 52400 44.7 56 60 11.53 39300 39.7 50 50 BAYHTR1419 BRK 2/1 19.20 65500 32/48 50*/60 50*/60 14.42 49200 27.7/41.6 44*/52 45*/60 BAYHTR1419 BRK with Single Circuit 1/1 19.2 65500 80 110 110 14.42 49200 69.3 96 100 Power Source Kit BAYSPEK140B NOTES: Circuit 1/Circuit 2(Minimum Circuit Ampacity for Circuit 1 includes Blower Motor Amps) ++i =000,BRK,PDC 000=pigtails,BRK=contains circuit breakers,PDC=contains pull disconnect IMPORTANT:Any power supply and/or combination power supply,circuit or circuits must be wired and protected in accordance with local Electrical Codes. 14 22-1774-18 TAANE® Electrical Data Unit Waring Diagram 4TEC3F24-36B1000A WARNING C A U T I ON AIA FLOW SELECTIONTERM SPEED HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! A LOW DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER B MED DISCONNECTS BEFORE SERVICING. TYPES OF CONDUCTORS. c HIGH Failure to disconnect power before servicing can Failure to do so may cause damage to the equipment. cause severe personal injury or death. L E G E N D BLAC THERMALLY 24 V. CFCK FAN B PROTECTED LINE V. MTR INTERNALLY A GROUND 2001230 V. PH-60 HZ. YELLOW ® JUNCTION POWER SUPPLY PER — .—..— — — — ---_--- -- - ---- CAPACITOR LOCAL CODES BK p WIRE CONNECTOR CN-I BK RD GR RD/] o I O TERMINAL o NOTE 1I l J TRANSFORMER _ _ �f FUSE LINE VOLTAGE RD 6{' RDII I r o of I I 3 WIRING BK 5 BK/l I� F RELAY CONTACT NO ------------ a{�-- — — ------------- --------I-------- ————-I MAGNETIC COIL LOW VOLTAGE ---�--WHIJ QI 6 I FEMALEWIRING 3_ WH/3 (MALE TERMINALS ) 2 WH/2 WH/I TNS m I Y Y Y POL. PLUG MALE (FELFAN I _ I CNI WIRE 3CON CONNECTOR TERMINALS) J . a � I m B A ` I (NOTE 2) -J FF FAN CAPACITOR NOTE 3 OA _ �FU I FU FUSE PCB PRINTED CIRCUIT BOARD RD PF POLARIZED PLUG (FEMALE HOUSING) PM POLAR;ZED PLUG (MALE HOUSING) i L- —-- i TNS TRANSFORMER a�COLOR OF WIRE BKIBL BLACK WINE WITH BLUE MARKER COLOR OF MARKER MODELS BK BLACK RD RED OR ORANGE BL BLUE WH WHITE GA GREEN TWE P L" — '— — —"—.'—`— '—' BR BROWN YL YELLOW PR PURPLE 2/4TEP- NOTES: 2/4TEC3F18-36 IPF I PM Y Y Y Y Y Y I. FOR 200V OPERATION SWAP RED TRANSFORMER LEAD AND INSULATED CAP 2 T G B 3 F 1 8-3 6 `1 2 3 4 5 6) ON 200V CENTER TRANSFORMER TERMINAL . T WG 0 1 8-3 6 � 2. WHEN HEATERS ARE USED, DISCARD I-PM WITH ATTACHED LEADS AND CONNECT I-PF TO THE MATING PLUG IN THE HEATER CONTROL BOX. I I I I I I 3. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS LOW VOLTAGE FIELD CONNECTION PRINTED FROM C800722PO I REV 1 1 22-1774-18 15 TAAME® Electrical Data Unit Wiring Diagram 4TEC3F42CI OOOA ® WARNING I I ® CAUTION LEGEND HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! 24 V. DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER LINE V. DISCONNECTS BEFORE SERVICING. TYPES OF CONDUCTORS. L GROUND Failure to disconnect power before servicing can Failure to do so may cause damage to the equipment. a JUNCTION cause severe personal injury or death. �f— CAPACITOR D C p WIRE CONNECTOR BLACK ( p tB —CF FAN O TERMINAL MSR THERMALLY TRANSFORMER 200/230 V. I PH.,60 HZ. YELLOW PROTECTED M'"1 POWER SUPPLY PER — INTERNALLY -r)_r FUSE LOCAL CODES F— 8K I RELAY CONTACT NO _ B RK D I CN t I GR RDII MAGNETIC COIL ' — PMALE TE FEMALE Ji NOTE 1 I WW (MALE TERMINALS) POL. PLUG MALE LINE o gl �I — I 1 2 3 (FEMALE TERMINALS) VOLTAGE RD a{F RDII �, ---F--3 I--- — : CN MIRE CONNECTOR WIRING BR 5{ BK/I IN � I I CF FAN CAPACITOR ---------- -------- LOW VOLTAGE 46 WHIJ F FAN RELAY WIRING ?_� WH/3 I I F I '� 6 I FU FUSE I 2 WH/2 = _ m m I PCB PRINTED CIRCUIT BOARD m4 I WHIZ TNS I PF POLARIZED PLUG(FEMALE HOUSING) PM POLARIZED PLUG (MALE HOUSING) TNS TRANSFORMER a I m B A I o�COLOR OF MIRE (NOTE 2) I NOTE ' '• BK/BL BLACK WIRE WITH BLUE MARKER m `---COLOR OF MARKER �Fp L " I BK BLACK RD RED OR ORANGE 2/4TEC3F42 I F I BL BLUE WH HITE GR GREEN AIR FLOW SELECTOR BR BROWN YL YELLOW PR PURPLE �m TERMINAL SPEED L. I ��—••r I ROTES: A LOW I. ON 200V OPERATION SWAP RED TRANSFORMER 8 MED-LOW I I LEAD AND INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL . C MED-NI D HIGH L .� 2. ATTACHEDTERS LEADSRE AND CONNECTUSED. RDI-PFPTONITH THE W ENHATING PLUG IN THE HEATER CONTROL BOM. z v 2/4TEC3F48-55 3 $ " m 3. FOR REPLACEMENT FUSE, USE LITTLEFUSE LMF TGB42-48 I-PF 3-2/10 OR HUSSMAN GNO 3.2110 FOR ALL MODELS. AIR FLOW SELECTOR I-PH 2\ TERMINAL SPEED 1�--�'-I-�•I-`-I-� A LOW I I I I II I MODELS B MEDIUM 1 1 1 1 1 1 2/4TEC3F42-55 C HIGH LOW VOLTAGE PRINTED FROM D802442P01 REV01 FIELD CONNECTION NOTE: Motor Speed Tap#5 must be selected if a time delay function is required. 16 22-1774-18 TAME® Electrical Data Unit Wiring Diagram 4TEC3F60E9000A AIR FLOW SELECTION ® WARNING ® C A U T I ON TERM SPEED I LGN HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! 2 NED-LO DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER T MED-HI DISCONNECTS BEFORE SERVICING. , TYPES OF CONDUCTORS. 4 HIGH Failure to disconnect power before servicing can Failure to do so may cause damage to the equipment. 5 NOTE cause severe personal injury or death. . BLACK GN FIA NS 43THERMALLY L E G E N D NOTE 5 L MTR 2 PROTECTED — 24 V. c 1 INTERNALLY LINE V. 2001230 V. I PH.,60 HZ. - C —L— GROUND POWER SUPPLY PER — LOCAL CODES (- CN-3 u JUNCTION BH—to^[�--01-81( CAPACITOR BR RD GR I — I Q WIRE CONNECTOR — CH-1 flDll O TERMINAL I g. __ _� TRANSFORMER NE VOLTAGE RD a{« RD/I I -2 f I CN m I V I-0 I m I -r-,,j FUSE WIRING BH s{ BH/l I� NOTE I FI ------------ c— WH/J— ------------- ——————— — ------_--____ RELAY CONTACT NO LOW VOLTAGE --« WIRING 3 WH/3 I 4 I I 4 6 I MAGNETIC COIL 2 WH/2 — I I t s POL.PLUG FEMALE TNS (MALE TERMINALS) & I Y Y Y POL. PLUG MALE m B A I 1 2 3 (FEMALE TERMINALS) (NOTE 2) NOTE 3 -• CH WIRE CONNECTOR m z I CF FAN CAPACITOR F FAN RELAY FU FUSE PCB PRINTED CIRCUIT BOARD L PF POLARIZED PLUG (FEMALE HOUSING) PN POLARIZED PLUG (MALE HOUSING) TNS TRANSFORMER i LC LINE CHOKE ®COLOR OF WIRE MODEL BK/B. BLACK WIRE WITH BLUE MARKER 2/4 T EC 3 F 6 0 L _ N — — — — — — — — J BK BLACK COLOR DF RED OR OA ORANGE a $ s m NOTES: BL BLUE WH WHITE GR GREEN PF BR BROWM YL YELLOW PR PURPLE I. FOR 2009 OERATION SWAP RED TRANSFORMER LEAD AND INSULATED CAP ( I-PM �Y�Y�YiY�Y�Y. ON 2001 CENPTER TRANSFORMER TERMINAL . l''N ?�°4T;4J 2. WHEN HEATERS ARE USED, DISCARD I-PM WITH ATTACHED LEADS AND CONNECT I-PF TO THE MATING PLUG IN THE HEATER CONTROL BOR. m 3. FOR REPLACEMENT FUSE, USE LITTLEFUSE LNF 3.2110 OR BUSSMAN GMO 3.2/10 FOR ALL MODELS. PRINTED A FROM LOW VOLTAGE 4. MED-LOW SPEED TAP, WITH A 90 SECOND OFF TIME DELAY. D 8 0 15 4 0 P O I R E V 0 9 FIELD CONNECTION 5. G TERMINATION NOT USED IN PLUG. 22-1774-18 17 TRWE" Field Wiring Air Handler with Single Speed Cooling Unit, 2 Stage beat T'STAT COOLING 2-STAGE HEAT/ 0.D. SECTION I-STAGE COOL AIR HANDLER (SINGLE SPEED) NOTE 3 R :R � ---- NOTES: FIELD I. LOW VOLTAGE WIRING TO BE N0. ADDED 18 A.W.G. MINIMUM CONDUCTOR. JUMPER Y y _y 2. WHEN FIELD-INSTALLED HEATERS ARE USED. DISCARD POWER LEADS G WITH POLARIZED PLUG PM-A AND G --_- CONNECT I-PF TO MATING PLUG IN THE HEATER WI CONTROL BOX AS SHOWN. WI 3. SEE HEATER WIRING DIAGRAM �2 FOR HEATING ANTICIPATOR SETTING. B B 8 INTER-COMPONENT MIRING ---- -————-24 Y. jjFACTORY SEE ROTE 2 -————-LINE Y.IWIRIUG ELD 1 PF -A LIDS Y.)WIRING SUPPL.PTR. CONTROL BOX REO. FOR FN1-1 Ul TO POSER SUPPLY TO POWER SUPPLY PER LOCAL CODES 1 PER LOCAL CODES a From[rvg,8801081 Reu1 AS DEFINED IN F IE ED RINI MG TABLE Rio° Handlers with Single Speed Cooling Unit, I Stage Heat COOLING T'STAT AIR HANDLER O.D. SECTION TOTE 4 (SINGLE SPEED) A R --- Y1.L011 VOLTAGE WIRING TO BE MO. Y `'-Y 18 A.tl.G.NI NI NUN CONDUCTOR. 2.WHEN FIELD-INSTALLED HEATERS ARE USED,DISCARD POWER LEADS WITH POLARIZED PLUG PM-A AND CONNECT G I-PF TO MATING PLUG IN THE HEATER G ---_ CONTROL BOA AS SHOWN. 3. IF OUTDOOR THERMOSTAT(ODTI IS W NOT USED,CONNECT WI TO W2 TD W3. L--�) 4. SEE HEATER WIRING DIAGRAM FOR HEATING ANTICIPATOR SETTING. NOTE 3 INTFR-COHPONFITT WIRING FACTOR, -LINE IRIN --� LIRE z1 Y. FIELD v.I0101 R9 ft.Dwg.M3DIMR .2 PI@PL.RIP. CPi9pL 901 TO POSER SUPILI I/ FO PW[R 5[mEf i YP EF LO[.Yu.1 - IS OL"ILEO IR LLL fl[ID RiPIRO Y,et[ s 18 22-1774-18 TAME® Field Wiring Field Wiring Diagrams for Air Handlers with Heat Pump HEAT PUMP T'STAT AIR HANDLER O.D. SECTION NOTE 5 (SINGLE SPEED) R 0 G NOTES: G '-- 1. LOW VOLTAGE WIfl ING TO BE NO. IB A.W.G.NI NINUM CONDUCTORS. 2.WHEN FIELD-INSTALLED HEATERS ARE USED, DISCARD POWER LEADS WITH BR/%2 POLAAI2ED PLUG I-PM ANO CONNECT OR HN I_PF TO MATING PLUG IN THE HEATER CONTROL BOY AS SHOWN. %Z 3. IF OUTDOOR THERMOSTAT(ODTI IS NOT USED,CONNECT WI TO W2 TO 13. ---Y13 4.CONNECT IH THIS MANNER IF O.D.UNIT NAS'F'CONNECTION. 9 5.SEE HEATER WIRING DIAGRAM FOR R G HEATING ANTICIPATOR SETTINGS. T INTER-CONPONEWT WIRING T 9H1T1 __=iiN[r.lnR1.5 F NOTE 4 •--F :f Y.Y.II LnELDEIR L ISE IMO LR DDR L I-If mrtt.en. 7 BDi RFD. From Owg.BS01082 Revl If 10 fDNO PERI POO- 1.110 ;ICQuSWVIs ILB LRLL fWCS IMO Ir Air Handler Subbase REAR FLANGE JOISTS JOIST HEADER f ONE INCH DUCT SPACERS— B FIG.1 FRONT A UNIT SUBBASE APPROX.3/4'FLANGES ON FIELD HEADER FABRICATED DUCT OR PLENUM. JOIST JOISTS NAILS rFLOOR FL®®B OPENING -SIZE MODEL N®. A BF�G.2 TAYBASE100 23-3/4 14-13/16HEADEp ER TAYBASE 101 21-3/4 14-13/16L MIN.SPACING TO ANY COMB TAYBASE102 26-3/4 14-13/16 FIG.3 MATERIIALUSTIBLE 22-1774-18 19 TAiME® 4T EC3 F24-6® Convertibility Six (6)Way Convertibility One Unit-4 Applications Easy Conversion to Opposite Side Access (Conversions 1-4) (Conversions 5&6) Horizontal Right Unit is shipped as (as shipped) ReNgerantConn ections 1 Horizontal right 0 Primary Condensate ® o o o 0 O Airflow °o 0 Airflow ° o Horizontal Drain pan Coil Supports Airflow ZPull coil out and Vertical Upfl®w r rotate the coil 180° (as shipped) One-step Conversion m °o Airflow Stand unit on end 0 0 3 Slide coil back in on supports and roll unit ConC Horizontal LoLeft (so primary \ condensate is dorm) Rotate Coil Airflow \ S Airflow 00 1 Bo Note connections ;i --�; and access are now Vertical®® ®w on back side of unit One-step Conversion from Horizontal left 6 CONVERSION APPLICATIONS ' 0o 0 0Airflow 1.Horizontal Right-(Front Access) Airflow 2.Vertical Upflow 3.Horizontal Left-(Front Access) 4.Vertical Downflow 5.Horizontal Right-(Rear Access) 6.Horizontal Left-(Rear Access) 20 22-1774-18 N N 21.00 V 1.14-1 1.14 m-J 1.64 1,64 .p DISCHARGE OPENING m ISEE FIG.( a b F IG.21 AGLOW a HEATER K.O. t B C I RCU I T A lA90E K a DISCK � BREAKER �� tPBd63 TOPVEW . 1.14 1.61 J GAS LINE SEE TABLE 1.38 BB LIQUID LINE SEE TABLE .B8° N 1.36• F10• I FO. 2 DUCT FLANGES 2.81 ISEE FIG. I HEATEfl ' A FIGEVE SI 314.14 TAPERED REVERSIBLE \ PIPE THREAD G O DT-AA FKL I FED,2 Ilm ND, J M J I K �■ 3.48 5.23 2TEE3F31A, 4TEE3F318 2TEC3F188, 248, 308, 361 ZJ _ F 4TEC3F188. 248, 308, 36B 19.22 18.22 TWE030CA R FILTER E 2TEE3F3TA, 4TEE3F318 ACCESS 4TEC3F428, 488,480 608 608 12.02 21.22 11.02 20.22 TMED40CA, 50CA CAL �� 21EE3F41A: 49A, 65A Iw N A III 3F408, 498, 658 2TEC3F558 23 71 22.12 rI ITEC3i558 0 SIM vm W MINIMUM UNIT CLEARANCE TABLE I.00 j r 18.07-1 r2.01 TO COMBUSTIBLE SERVICE 441 1.00 IAL CLEARANCE a (REOUMATERIREDI (RECOMMENDED) 0) SIDES 0' FRONT 0' 21' BACK 0' 0• FLOW GAS LINE LIQ LINE INLET DUCT 0• 1• RETtffi MODEL NO. A B C D E F G OUi'ET EFOR UTHE FIRST03 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALLED 4TEC3F24B 43 21.50 19.50 15.66 3.62 1.89 N/A TXV/NB 5/8 5/16 EXCEPT MODELS BAYHTR1405. 1408, AND 1410 ARE APPROVED FOR 0' PLENUM AND DUCT 4TEC3F36B 45 21.50 19.50 17.66 3.62 1.89 N/A TXV/NB 3/4 3/8 CLEARANCE IN THE UPFLOM CONFIGURATION ONLY ON TWE•P MODELS. 1.00 4TEC3F42B 51.75 23.50 21.50 22.41 1 3.62 1.89 N/A I TXWNB 1 3/4 1 3/8 BOTTOM VIEW 4TEC3F48B 57.90 23.50 21.50 1 27.57 1 3.62 11.89 1 32.39 1 TXV/NB 1 7/8 3/8 4TEC3F60B 9 wo Mechanical Specification Options General Casing Filters Blower coil units shall be completely Units shall have a rugged sheet met- Filters shall be included as standard, factory assembled including coil, con- al and steel frame construction and one-inch low velocity semi-perma- densate drain pan, fan, motor, filters shall be painted with an enamel fin- nent type (except 5-ton - washable and controls in an insulated casing ish. Casing shall be insulated and filter). that can be applied in horizontal or knockouts for electrical power and Accessories vertical configuration. The "F" model . control wiring. Electric Heaters — Shall be avail- indicates an "Air-TiteTM" model with Refrigerant Circuits able in a wide range of capacities 4.2 "R"value insulation and addition- The 4TEC3F units .have a single and voltages with various staging al sealing systems. refrigerant circuit. 4TEC3F24-60 re- options, and plug-in control wiring. This line of 4TEC3F Air Handlers frigerant circuit shall be controlled by Heaters shall fit inside the internal provides exclusive compact size com- a factory-installed non-bleed thermal compartment. bined with simple 6-way convertibility expansion valve. in sizes up to 5 Tons.The unit ships in Coil the vertical upflow configuration and ,aluminum fin surface shall be me- converts to horizontal right just by chanically bonded to 3/8-inch OD laying the unit on its side. No tools re- copper tubing. Coils are factory pres- quired. Simple coil rotation provides sure and leak tested. downflow and horizontal left applica- tions. Fan Forward curved, dynamically bal- The 6-way convertibility provides you anced and statically balanced with inventory benefits and service/instal- 3-speed direct drive shall be stan- lation flexibility.The simple conversion dard, fan.motor bearing shall be per- provides opposite side access for in- manently lubricated. stallation and service. c Controls These Air Handlers enjoy the best Low voltage pig tails, fan contactor, us reputation in the industry.Superior air- and plug-in module for accessory ' flow, great sound level, reliability and electric heat control shall be includ- Intertek performance are responsible for the ed. industry leadership.We are not about to give up such top performance. Units shall be certified to UL 1995. 06/12 T E® Trane 6200 Troup Highway The manufacturer has a policy of continuous product and product data improvement and it reserves the right Tyler,TX 75707 wwrw.trane.com to change design and specifications without notice.