Loading...
HomeMy WebLinkAbout47960-Z „Jfg11FF0i�- ro�O 1pG,, Town of Southold 8/23/2022 y� P.O.Box 1179 y 2 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43356 Date: 8/23/2022 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 1260 Fairway Dr., Cutchogue SCTM#: 473889 Sec/Block/Lot: 109.-5-14.7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/16/2022 pursuant to which Building Permit No. 47960 dated 6/15/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built”air conditioning system as applied for. The certificate is issued to Kohart,Christopher&Therese of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47960 8/16/2022 PLUMBERS CERTIFICATION DATED A riz 9dignature SUFFDd� TOWN OF SOUTHOLD �o`p °oy BUILDING DEPARTMENT TOWN CLERK'S OFFICE Ca • �:;� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47960 Date: 6/15/2022 Permission is hereby granted to: Kohart, Christopher 18 Gilbert St Ridgefield, CT 06877 To: legalize "as built" AC system as applied for. At premises located at: 1260 Fairway Dr., Cutchogue SCTM #473889 Sec/Block/Lot# 109.-5-14.7 Pursuant to application dated 5/16/2022 and approved by the Building Inspector. To expire on 12/15/2023. - Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector pF SOUryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �� • �o sean.devlinCa)town.southold.ny.us �yC0UN1`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Christopher Kohart Address: 1260 Fairway Dr city:Cutchogue st; NY zip: 11935 Building Permit* 47960 Section: 109 Block: 5 Lot: 14.7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 1 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixturesTime Clocks Disconnect 2 Switches 4'LED Exit Fixtures Pump Other Equipment: one mini split w/one blower head and one AC w/ one AH Notes: " AS BUILT NO VISUAL DEFECTS " HVAC August 16, 2022 Inspector Signature: t> Date: S.Devlin-Cert Electrical Compliance Form o�aOF SOUIyo 7q &0 - - 12 V V .-j"l �� # # T. TOWN OF SOUTHOLD BUILDING DEP courm,��'` 631-7.65-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ /] RENTAL REMARKS: WALS ft-,t,,C-e z c e G DATE 2 2i INSPECTOR Q OF SOUT,�°� # TOWN OF SOUTHOLD BUILDING DEPT.. °`ycou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ rSULATION/CAULKINGFRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ . ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: b-eA&4v 6mvivo v DATE y INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS j FOUNDATION(IST) O y -------------------------------------- FOUNDATION(2ND) • �z H t ROUGH FRAMING& PLUMBING 9 � INSULATION PER N.Y. STATE ENERGY CODE l ' C T FINAL ADDITIONAL COMMENTS TZ O o v � �z rn N N � ~O _ � z H d t�J • b H f o�SufFotq�oG a TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.Roov. Date Received APPLICATION FOR BUILDING PERMIT In For Office Use Only PERMIT N0. �l Building Inspector: MAY " wE 6 LULL BUILDING DEPT. Applications and forms must be filled out in their entirety. Incomplete TOWN OF SOUTHOLD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: May 13, 2022 OWNER(S)OF PROPERTY: Name:Christopher & Therese Kohart SCTM#1000-109.-5-14.7 Project Address:1260 Fairway Drive, Cutchogue 11935 Phone#:203.300.7394 Email:chris.kohart@gmail.com Mailing Address:18 Gilbert Street, Ridgefield CT 06877 CONTACT PERSON: Name:Christopher Kohart Mailing Address:18 Gilbert Street, Ridgefield CT 06877 Phone#:203.300.7394 Email:chris.kohart@gmail.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTORINFORMATION: Name:Kolb Heating & Coolint Mailing Address:11500 Sound Avenue, Mattituck NY 11952 Phone#:631.298.5527 Email:jurawski@kolbmechanical.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: I]Other To legalize split A/C unit installed by previous owner in 2018 $4500 actual Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo I 1 PROPERTY INFORMATION Existing use of property:one family home Intended use of property:one family home _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to residential this property? ®Yes 0 N IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for'the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,'for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By f ri a _ er A. Kohart ❑Authorized Agent BOwner Signature of Applicant-^-� Date: May 13, 2022 �Kv- STATE OF RJ EiAhF9W SS: COUNTY OF being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1 day of ��7 ,20 gq-2- ry Public CHIP KEATING NOTARY PUBLIC-CONNECTICAROPERTY OWNER AUTHORIZATION MY COMM.EXPIRES 12/31/20c^ (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 I i 1= � BUILDING DEPARTMENT- Electrical Inspector �^ ��✓ TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 , ► Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogerr(ob-southoldtownny.gov — sea nd(aD-southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: i JOB SITE INFORMATION (All Information Required) Name: K Ov- Address: ��(�� Va I i(fit7 gin) '�,✓�. �,c� f1 (,t Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: ( 0 Block: Lot: f BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): �- C Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# F1 New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y MN Additional Information: PAYMENT DUE WITH APPLICATION n IM,�� i I ��✓�¢� / � � � � CHRISTOPHER A. KOHART 18 GILBERT STREET RIDGEFIELD CT 06877 +1 203.300.7394 chris.kohart()amail.com June 16, 2022 R ltn I� II r' JUN 2 1' 9A99 Southold Town Building Department BUILDING DEPT. PO Box 1179 TOWN OF SOUTHOLD Southold NY 11971 Attention: Caitlin Westermann Subject: 1260 Fairway Drive—Split A/C permit Dear Caitlin, Per our email correspondence yesterday,enclosed please find check 3206 representing the permit fee. Please forward the documentation to me at the above address. Thanks again for your assistance in this matter! Sincerel , risto r A. Kohart Inv CHARLES R.CUDDY ATTORNEY AT LAW fn `�' GL 445 GRIFFING AVENUE RIVERHEAD,NEW YORK Mailing Address: TEL: (631)369-8200 P.O.Box 1547 July 12, 2022 FAX: (631)369-9080 Riverhead,NY 11901 E-mail: charlescuddy@optonline.net Town of Southold- Building Department Town Hall Annex 54375 Main Road Southold, New York 11971 Re: Permit No. 47960 Premises : 1260 Fairway Drive, Cutchogue, New York To Whom it may concern: Enclosed please find the following in connection with the Permit No. 47960 : 1 . Application for Building Permit signed by the owner, Robert C. Farley. 2 . Building Permit 3 . Southold Approval Notice It is our understanding that upon receipt of the attached documents a final inspection can be scheduled and Certificate of Occupancy issued thereafter. Very truly yours . C/�v� / Charles R. Cuddy CRC: Dmc Enclosures En JUL ( 4 2022 =i BUILDING DEFT: TOWN OF SOUTHOLD S.C.T.M. NO. DISTRICT: 1000 SECTION:709 BLOCK:5 LOT(S):74.34 TEE LANE ryhOry'1 v N 0 LOT 6 M N. N88e59'20"W 218.63' MON. CAN Iv ' PIPE p] -p Q 76.6' •8'1 FC x X 4'ESTATE FENCE 9�X X X �� 24.6' n ' CO 0.5'E • ti GARAGE N 0.5PH41.T DRNEWAY GVa 4 ••z i c+ BE�O 9� O c 0' N! 9.3, O • O MCR PATIO CO REO m EN O 0 106.5• D.s' 2.9 Cil a w• 1 STY FIRM. ; • maNy DWELLING >< W f w 11260 R EE LOT 7 L.2 BRIC m STOP 0p W.M. 3. = 11.1' 4 o• •aw aF•�•1 • O 2.5' 19.8' . 0-4O m ~ O m tiNC'I6RICN FA•V O Sf00P 1•.. �• DO W I o n � of o • FC � •� 1.4'E 'X w 2.1'N4'ESTATE FENCE FC, N 1.6's C441 LIN-FENCE MON. x0.4'5 2.65 220.00' I11.5'E S88"59'20"E x Lor a ® E 11-17 I" V E MAY 1 6 na 1 .3D BUILDING DEPT TOWN OF SOUTHOLD UPDATE 11-03-21 AREA:40,673.73 SQ.FT. or 0.93 ACRES ELEVA 77ON DATUM: ------------------------- UNAUTHORIZED ALTERAT70N OR ADD1770M TO THIS SURVEY IS A WOLA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TIRE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU77ON LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE S7RUMRES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: LOT 7 '(E0FNEtr CERTIFIED TO: CHRISTOPHER A. KOHART; MAP OF: FAIRWAY FARMSp H M w0 o THERESE L. KOHART; FILED: FEBUARY 15, 1974 AS #6066 `2lS }°y�� FREEDOM LAND TITLE AGENCY; SITUATED AT: CUTC i OGUE 4 x FIDELITY TITLE INSURANCE COMPANY OF NEW YORK; TOWN OF: SOUTHOLD F JIv KENNETH M. WOYCHUK L.S. SUFFOLK COUNTY, NEW YORK 2'p 050882 v< Land Surveying and Design N P.O. Box 3, Mattituck, New York 11952 FILE () 14-126 SCALE: 1"=30' DATE: AUG. 28, 2014 PHONE (631) 298-1588 FAX (631) 298-1588 N.Y.S.OC N0.50227 .inteining the record.of Rebert J.H..—..y C rod t 1 APPROVED AS NOTED DATE: B.P.# FEE: (� BY: NOTIFY.-BUILDING D'PARTMENT AT 765-'1802- 8 AM "IO 14 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION -:TWO REQUIRED FOR POURED CONCRETE .2. ROUGH - FRAMING & PLUMBING 3. INSULATION 11 4. FINAL - CON,--,TRU-l'Ti^N MUST BE COMPLETE ALL CONSTRUCT IOP� SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF G BOARD S '•T ' VVhI-TRUSTEES kyi_.DEc__ -.�uUPANCY OR USE IS UNLAWFUL. WITHOUT CERTIFICAT" OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED 1 AAMITSUBISHI k ELECTRIC Heating and Cooling Job Name: Engineer: Purchaser: Location: Submitted To: For: Reference Approval Construction Submitted By: Unit Designation: Schedule No. FS N1 Capacities: Cooling Rated(Max.-Min)Btu I hr ..........................12,000(13,600-2500) Cooling Rated Power(Max.-Min)Watts...........................870(1,150-170) S SEER/EER .................i...................................................26.1 /13.8 # Sensible Heat Ratio........i......................................................................0.830 i. Moisture Removal Pints/hr........................................................................1.9 Heating @47F:Rated(Max:Min.)Btu/hr.............13,600(21,000-3,700) Heating @47F:Rated Power(Max.-Min)Watts...............950(2,300-280) „a Heating @17F:Rated(Max.)Btu/hr.....................................8,000'(13,600) Heating @17F:Power(Max.Power)Watts.................................720(1,900) HSPF IV NA(NAH)/COP @ 47F....................................12.5(11.5)/4.20 Heating @5F:Rated(Max.)Btu/hr....................................................13,600 - Indoor Unit Specification: ®�=� Power Supply''............................................................208/230Vac 14)60Hz .,,.,...,. Indoor-Outdoor Power Connection MCA...........................................................................................................1A Iboortsrmimtbmk Weight.................................................................................29 lbs(13.15 Kg) Ws 83(D Sound(quiet-L-M-H super H).........................cooling 21-24-29-36-41 dB(A) -- Sound(quiet-L-M-H-super H..........................heating 21-24-29-36-42 dB(A) Airflow(quiet-L-M-H super H).......................Dry CFM 137-167-221-304-398 i i - h(doodoumoor Airflow(quiet-L-M-H super H)......................Wet CFM 117-143-190-261-342 Airflow(quiet-L-M-H super H)..............Heat Dry CFM 140-167-225-325-454 tlod( Moisture removal...............................................................................1.9 pt./h sts ss 1 L1 S fa�oort Refrigerant Piping: 9mdr= -=--� Liquid.....................................................................:...............................1/4"(6.35mm) ftwmppy Gas.......................................................................................................318"(9.52mm) Connection method..............................................................................................flared Electrical Wiring:*1 Indoor unit Power is supplied by the outdoor unit on terminals S1,S2 Condensate drain Connection OD..............................................................518(15.88) Main Input power on terminal L1 and L2 Operating Range Standard Features: Mode I Indoor Intake Air Temp. Outdoor Intake Air Temp. Highly energy-efficient system with quiet operation Max. 90°F/32°C D.B. 73°F123°C W.B. 115°F146°C D.B. 0Energy Star rated Cooling "Powerful Mode"function permits system to temporarily run at a Min. 67°F/19°C D.B. 57°F/14°C W.B 14°FI-10°C D.B. lower/higher temperature with an increase( fan speed,which quickly Heating Max. 80°F127°C D.B. 67°F/19°C W.B. 75°F124°C D.B. 65°F/18°C W.B. brings the room to the optimum comfort level Min. 70°F/21°C D.B. 607/15°C W.B -13°F/-25°C D.B.-14°F-22.5°C W.B Pre-charged Refrigerant(up to 25ft./7.6M of piping one way) Controller Options : 5 year parts,7 years compressor warranty • Wireless Wall-mounted Remote Controller Kit(MHK1)* • Base Heater(MAC-640BH-U)included in MUZ-FH12NAH • Portable Central Controller(MCCH1)* Easy maintenance with self-diagnostic feature • Outdoor Air Sensor(MOS1)* Nano Platinum airuri n filter • Wired Wall-mounted Controller(PAR-31 MAA requires MAC-3331F)* p 9 • Simple NSA Remote Controller(PAC-YT53CRAU requires MAC-3331F)* Variable compressor speed inverter technology • Control Interface(MAC-3331F)(Remote ON/OFF)(Remote errodoperation display) a Low ambient cooling(14°FI-10°C) • Auxiliary HEAT output signal on CN24 requires optional cable MAC-1710RA-U 0 Auto change-over between heating and cooling modes. • M-NET using NAC-3331F 0 Low ambient heating cut-out/restart temp. (-18°FI-27°C)(-14°FI-25'C) *See Submittal for information on each option. • 3D i-see sensor Above capacity based on AHRI 210/240 test condition 0 Split vanes Specification subjectto change without notice 0 MUZ-FH12NAH-1-Outdoor unit blue fin coated coil SB_MSZ-FH1 2NA_&_MUZ-FH1 2NAH(-1)_20191 0 page 1 of 4 ©Mitsubishi Electric Sales Canada Inc.2016 I 1. SU13MJTTAL DATA: MSZ-FH,12NA MUZ_F1FI`I2NA(H)- Outdoor Unit Specification: Power Supply*'. ..........................................................208/230Vac 10 60Hz MCA......(*)................................................................................................11A Breakersize.............................................................................................15A Weight............................................................................. .....83 lbs(37.6Kg) Sound(cooling).................................................................................51 dB(A) K- Sound(Heating)................................................................................55 dB(A) Refrigerant Piping: Liquid.......................................................................................1/4"(6.35mm) Gas..........................................................................................3/8"(9.52mm) Max.height difference..............................................................40 ft.(12.5m) Max.length...............................................................................65 ft.(19.8m ConnectionMethod................................................................................flared 0 Windscreens(ME-FR-15-17) OWN O Specification subject to change without notice Dimension inch(mm) Notes: SB—MSZ-FH12NA—&—MUZ-FH12NAH(-1).201910 page 2 of 4 @ Mitsubishi Electric Sales Canada Inc.2016 • i 1 • MSZ-FH06NA MSZ-FH12NA MSZ-FH15NA Unit: inch N16- 1.1116 Oblong We 7116*1 V1 6 Obow hoe lnuapayon-vla�c.> 36-7116 33.518 318 64-4 s n s tn44a1_a1y1__� 2.616 15.51113 114-1111133•D;s6 Air In !`t¢lall hate 03 —3116 ! I �lnstanallon Hate ui � I y 1� ��•0116 � 11'-x- `° Drain hale -! s - Ny +•318 1� 27•Ii1s4 { 4• 1B 3 w x•318 _,__,L_ F-i �rut.a..e. 5 9 r"_, (� - 4 .•SaF] 1116 y, ""�-ii T"_' MSZ•FH0911 (MSZ•FH 1 SNA) ,Lz.l �sullsn J1.7t1f P.0 gl-� k71's 1,A3F n�asnnaganCl $ _Qt41li364Rarmdtonnscsant]I'sy� Qb4lllfarcicannrsObB DfainVi'. IFlltalonaI."R%.om-i'm alaso0.0 N:IranQl•1,dCr-r1lca�lcsll.^3800 W .y i SB_MSZ-FH12NA_&_MUZ-FH12NAH(-1)_201910 page 3 of ©Mitsubishi Electric Sales Canada Inc.2016 t MUZ-FH09NA MUZ-FH09NAH MUZ-FH12NA MUZ-FHI2NAH unit:inch REQUIRED SPACE _ •t 4 in. (100 mm)or more vihon� _ front and sides of the unit are tlear ti At tl rn�r x r ct I1t3?lPfl$ 1U?L11 fiah�r,:.ft.571?�IE'.0td-FH7�/Tr'FIAH1 �:1.'. ME 74 Ck- CA -2 When any,2 sides of left. fight =rte s and rear.of the unit are clear �7.holes3r5MPJL tirnh�;nr-1 , ft y r ei Liquid refrapdtard pipe joins { Remt�p-rant pMe(nbred)0 IA ,—_ Gas refrigamm p1pa joint �le'� Retrgerant pipe ltlareo 03�b G -ii7iRtch'o i�iti151G, 'N NOTE: Mount unit 12 inches above local snow height N O di L I�a�t X W L: `N ® MITSUBISHI /®ELECTRIC Chraaarges for the Better SB_MSZ-FH12NA_&_MUZ-FH12NAH(-1)_201910 page 4 of ©Mitsubishi Electric Sales Canada Inc.2016 1 2 Page No. of Pages KOLB MECHANICAL CORP. Heating and Air Conditioning 11500 Sound Ave, P.O.Box 106 Mattituck, NY 11952 (631)298-5527/Fax(631)298-5534 PF'WRRLTBWp TQ P'�gS 1) 987-6867 1"TTay 10, 2018 STIEb Box 1248 JOS." 6 Fairway Drive c'T6 ® , NY 11935 JOtlfftflftue, NY 11935 EMjftQjMonAnn13 gmail.com CE9LZ)VgE We he, supmit spec'kation ar� estimate f t F'roviCie p ins al� new Witsubishi ductless H2i Hyper Heat high efficiency heat pump heating and air conditioning system for the Sunroom to consist of the following: • One (1) Mitsubishi, model #MSZ-FH12NA, 12,000 BTU, ductless H2i high efficiency wall fan coil unit to be installed in the Sunroom, exact location to be determined. • One (1) Mitsubishi, model #MUZ-FH12NA, 12,000 BTU, H2i Hyper Heat high efficiency outdoor heat pump condensing unit to be installed at the residence exterior, exact location to be determined. Unit shall be set on a pre-cast slab. Includes: • One (1) Mitsubishi remote thermostat controller. • Schedule 40 PVC condensate drain. • Pre-cast condenser slab. • Armaflex insulated type "L" nitrogenized refrigeration piping. • R410a environmentally compliant refrigerant. • Low voltage HVAC control wiring. • All necessary materials, labor, installation and start-up. • Line voltage power wiring, by Electrician. • Cutting, patching, painting, and/or framing of sheetrock and carpentry for HVAC, if required. • Any applicable permits, certificates, or associated fees, if required. *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,until fully paid All past due accounts shall be charged interest of 1.5%per month. All payments Due Upon Receipt. Ze VtIDP000 hereby to furnish material and labor—complete in accordance with above specifications,for the sum of: Base Total Options Total Grand Total Payment to be made as follows: y All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra Authorized costs will be executed only upon written orders,and will become an extra charge over and above the Signature estimate. All agreements contingent upon strikes,accidents or delays beyond our control. Owner to may Note:This project be carry fire,tomado and other necessary insurance. Our workers are fully covered by Workman's 1 y Compensation Insurance. withdrawn by us if not accepted within 16 days 2ACtept anc¢ of 'WIn>COPO011111 The above prices,specifications and 4nn ,;: �, r. conditions are satisfactory and are hereby accepted. You are authorized to Print Name do the work as specified. Payment will be made as outlined above. Date of Acceptance X Signature Page No. 2 of ? Pages KOLB MECHANICAL CORP. Heating and Air Conditioning 11500 Sound Ave, P.O.Box 106 Mattituck, IVY 11952 (631)298-5527/Fax(631)298-5534 PR POSA UBMITTEDTO P'e6l) 987-6867 "'Pay 10, 2018 °Ann ompson '7 56 Box 1248 JOS° � Fairway Drive C1'rt6TR6Rff, NY 11935 'Otffffi8bue, NY 11935 EMT6Wffi%onAnn13@gmail.c_om CE�IZPf yE '',k� I ,yy We hereby submit specifications and estimates for: Warranty: • All work to be done in a professional manner by trained installers and service personnel: • One year parts & labor service during normal business hours on above system. • Exclusive Mitsubishi Elite Diamond Dealer Twelve year parts and compressor warranty. • All factory warranties honored. I Total Investment: $ 4,500.00 *Upon acceptance,please date,sign by the"X"and return yellow copy with your deposit. KOLB MECHANICAL HEATING&AIR CONDITIONING In the event this account is forwarded to counsel for collection the purchaser shall be liable for all reasonable fees of Kolb Mechanical Corp., It is the responsibility of the Homeowner to have qualified Service Mechanics maintain heating and air conditioning equipment as required by man- ufacturer in order to preserve warranties. All equipment shall remain property of Kolb Mechanical Corp.,until fully paid All past due accounts shall be charged interest of 1.5%per month. All payments Due Upon Receipt. �(1Q`�COpO�e hereby to furnish material and labor-complete in accordance with above specifications,for the sum of: Base Total Options Total Four Thousand Five Hundred Dollars and xx/00 - - - - - - - - - $4,500.00 Grand Total Payment to be made as follows: , 50% Deposit; 50% Balance Due Upon Completion & Start-up All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra Author ed f ' costs will be executed only upon written orders,and will become an extra charge over and above the Signa re estimate. All agreements contingent upon strikes,accidents or delays beyond our control. Owner to c may b carry fire,tomado and other necessary insurance. Our workers are fully covered by Workman's withdrawn by us if not accepted within 16 days Compensation Insurance. 21captante of 'TWOpO OOT The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authorized to Print Nam do the work as specified. Payment will be made as outlined above. Date of Acceptance a X Signature