Loading...
HomeMy WebLinkAbout46645-Z rra Town of Southold 8/14/2022 o P.O.Box 1179 o _ 53095 Main Rd 4 foo rJ Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43330 Date: 8/14/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 380 Madison St.,Greenport SCTM#: 473889 Sec/Block/Lot: 40.-5-18 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/23/2021 pursuant to which Building Permit No. 46645 dated 8/2/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Catalan,Zenaida of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46645 7/19/2022 PLUMBERS CERTIFICATION DATED ut o ze Signature fat , TOWN OF SOUTHOLD BUILDING DEPARTMENT C2 x TOWN CLERK'S OFFICE oy • � , SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46645 Date: 8/2/2021 Permission is hereby granted to: Catalan, Zenaida 15 Madison St Greenport, NY 11944 To: Install roof mount solar panels to existing single family dwelling as applied for. At premises located at: 380 Madison St., Greenport SCTM # 473889 Sec/Block/Lot#40.-5-18 Pursuant to application dated 7/23/2021 and approved by the Building Inspector. To expire on 2/1/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ADDITION TO DWELLING $50.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL. 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 7/22/2021 New Construction: Old or Pre-existing Building: x (check one) Location of Property: 15 Madison Street, Greenport, NY 11944 House No. Street Hamlet Owner or Owners of Property: Zenaida Hernandez Suffolk County Tax Map No 1000, Section 040.00 Block 05.00 Lot 018.000 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Sung Lee Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 100.00 Applicant Signature pF SOUryOI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q �► • �o sean.deviin(,Stown.southold.ny.us Southold,NY 11971-0959 Q�yCOU�'�^�\ BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Zenaida Catalan Address: 380 Madison St A.K.A. 15 city:Greenport st: NY zip: 11944 Building Permit* 46645 Section: 40 Block: 5 Lot: 18 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Island Electrical Corp License No: 37608ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor. X Pool New X 2nd,Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 17.86 kW Roof Mounted PV Solar Energy System w/47 Hanwha 40OW Modules, IQ3 Combiner w/230x4 215x1, 80A Fused AC Disconnect Notes: Solar Inspector Signature: Date: July 19, 2022 S.Devlin-Cert Electrical Compliance Form n�1� Building Department Application JUL Z 3 2021 AUTHORIZATION B�D,�G DE,pT. (Where the Applicant is not the Owner) 'T0WT4,OIq rWT'a0LD 1� Zenaida Hernandez residing at 15 Madison Street, Greenport, NY 11944 (Print property owner's name) (Mailing Address) do hereby authorize Sung Lee (Agent) to apply on my behalf to the Southold Building Department. 7/22/2021 (Owner's Signature) (Date) Zenaida Hernandez (Print Owner's Name) SOUTyolo �� �� Mz� f TOWN-OF SOUTHOLD BUILDING DEPT. . 765-1802 INSPECTIO-N [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: % f AAS W " G Q .fq ol'oes- 00, lu, LAC/11 d .LOQ W V NC `5 . o DATE ' SA& INSPECTOR OE SOUTyO� --- - V # # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL EOIRVOI-11 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: A6461 < < F DATE Y INSPECTOR so(/j�O # TOWN OF SOUTHOLD BUILDING DEPT. °`ycou631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ . ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: o No 6uz, -- DATE DATE lel < INSPECTOR FSO u► o uTyolo # TOWN OF SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: n nn l �<< (( �i� Vi� �✓ it� 1 lh�--S � �� yt7 DATE 1/ INSPECTOR FIELD:INSPECTION REPORT DATE " CC3NIIVIN FS FOUNDATION (IST) ;...':: ::::; .. . :. ..:... .''. rA FOUNDATION (2ND.) .. ... ........ ' ROUGH FRAMING: PLUMBING: INSULATION.PER N.Y. STATE ENDRGY CODS FINAL'. .. Vli l � A;DDZTI. iN 16pk. off'. 777777 �A, Z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX: 631 765-9502 f�/ (/ Surve Southoldt wnny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 r (� �; Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 -J w J U L 2 3 202 Mail to: Disapproved a/c ` Phone: Expiration 20 � J lf`>J� Building Inspector APPLICATION FOR BUILDING PERMIT Date 7/22 20 21 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 45 Fairchild Ave.Suite B.Plainview,NY 11803 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Cnntrartnr Name of owner of premises Zenaida Hernandez (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 37608-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 15 Madison Street,Greenport House Number Street Hamlet County Tax Map No. 1000 Section 040.00 Block 05.00 Lot 018.000 r r Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single Family Residence b. Intended use and occupancy Single Family Residence 3. Nature of work(check which applicable):New Building Addition Alteration x Repair Removal Demolition Other Work Solar Panels (Description) 4. Estimated Cost $50,543.80 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO x 13.Will lot be re-graded?YES_NO Will excess fill be removed from premises?YES_NO 14.Names of Owner of premises Address Phone No. Name of Architect SAMUEL DEKYEM Address Phone No Name of Contractor Sung Lee Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO x *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: .1� �+ COUNTY OF A o Z.cri Co=$ Sung Lee being duly sworn,deposes and says that(s)he is the applicant g Z mcg 8 (Name of individual signing contract)above named, m W(00 u3 N 0 (S)He is the Contractor 3 3: Co ow Z a) (Contractor,Agent,Corporate Officer,etc.) t OC> C.. 3 Z 0 of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; a (D ro o that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be d.1 performed in the manner set forth in the application filed therewith. o E Sworn Zto before me this Jul 27 ay of y 20 Notary Public Signature of Applicant �. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o t Town Hall Annex - 54375 Main Road - PO Box 1179 ; o :} Southold, New York 11971-0959 ;t ao Telephone (631) 765-1802 - FAX (631) 765-9502 roger-4-southoldtownny.gov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Island Electric corp. Name: Jeffrey Marinello License No.: ME-37608 email: permitsli@momentumsolar.com Address: 76 Kerrigan Street, Long Beach NY 11561 Phone No.: 516-218-5824 JOB SITE INFORMATION (All Information Required) Name: Zenaida Hernandez Address: 15 Madison Street 5yu MCLA,S V%, Cross Street: North Rd Phone No.: 6314804157 Bldg.Permit#: qCc Co 4 email: zpalencia294@gmail.com Tax Map District: 1000 Section: 040.00 Block: 05.00 Lot: 018.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of Solar Panels; Rooftop, Rail less, Grid tied,47 MODULES, 17.86 KW Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals I � 1 � ���' v Ali BUILDING DEPARTMENT- Electrical Inspector (C Gam'•,: TOWN OF SOUTHOLD ' Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 .� rogerr a@southoldtownny.gov - seand(a southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Island Electric corp. Name: Jeffrey Marinello License No.: ME-37608 email: permitsli@momentumsolar.com Address: 76 Kerrigan Street,Long Beach NY 11561 Phone No. 516-218-5824 JOB SITE INFORMATION (All Information Required) Name: Zenaida Hernandez Address: 15 Madison Street g V--'- Cross Street: North Rd Phone No.: 6314804157 small: zpalencia294@gmail.com Bldg.Permit#: `-((r to Tax Map District: 1000 Section: 040.00 Block: 05.00 Lot: 018.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of Solar Panels; Rooftop, Rail less, Grid tied,47 MODULES, 17.86 KW Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect - Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments Vi Suffolk ,County Dept. of Labor, LicensingConsumer Affairs HOME IMPROVEMENT LICENSE. Name n SUNG LEE R i . Bus nes - 'Name- Thi.c rckrfifioaz fh�tf fhe . . ..Mdul Licensed PRO CUSTOM'! SOLAR''L' LO B bearer is Y by tbei County or s offal License Number: H-575,7 Rosalte rago Issued,.: i -G/06120. 6 C m,mi'ssianer Expire, 10/0412022 pta, Of - * Lte-ens' C i _ i ne-s.. ,,.s ma.- r LO ND T the- Cou 1!� of' ' �a �' ��, ! � ► 12 -2 Issued.-M,- _ _ _ YORK workers'Compensation CERTIFICATE OF INSURANCE COVERAGE STATE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured PRO CUSTOM SOLAR LLC DBA MOMENTUM SOLAR 3096 HAMILTON BOULEVARD (732) 902-6224 SOUTH PLAINFIELD,NJ 07080 Work Location of Insured(only required if coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 27-1242539 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) First Unum Life Insurance Company TOWN OF SOUTHOLD 54375 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" SOUTHOLD , NY 11971 955431 3c.Policy effective period 11/01/2020 to 11/01/2021 4. Policy provides the following benefits: R A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: X❑ A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. 10/29/2020 °""==' Date SignedBy Kasey Brady M (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 207-575-1519 Name and Title DBL Specialist IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) ILII III IIII�IIIII��IIII�I�I�IIII��I�III�I�I�I�IIIIII III DB 120.1 (10-17) Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box"1 a"for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law. The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first, two thousand and twenty-one,the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (10-17)Reverse �Nzswg, Workers' CERTIFICATE OF 4sTATk Umperis;Won B6ard NYS WORKERS' COMPENSATION INSURANCE COVERAGE 'tat—Loul Name&Ad6ess 61 Ingured(usu sircut address only) ob.Business T cYzpkcnc Number of Insureo Pm Pu-,.16m Solar LLC: ?32-1.1102-6224 dba Nomeriturh SbIq 303DS Hamilton[XVd, -1c.NYS Unemp)?yrnent insurance EmpfoyarRoIstTatbri Nunfti ul south Plairiii0d,NJ WOE0, Work Lac tion of ln:Lorql d is wcXally hiti4ed co Id.Foral Ewaoyw Identiliedtion-Number..3f Insured ciSooial Secully "re qelv YOA&we'.le;.a 108P-up Ptwcy) Number 2.Name ane AcIdresr i�fShfdy'Requo�-,'ingoroo,,W C-6y0w qu 3 a.Ne"of In Kurverp-jO a rrinrl (Entry Being.L,IsM as.tI1a-Ger1Irj'cate-Zd,,) 7urich'Amodw--i,.Imurando Co. Tomof Southold 13b,Pcl�q f1um5,r pl EnIII,Llslad In Box'In' ' 53095 Middle Road PIC-44 79937-0 Southold, NY 11971 ii So,Clollpy 09ove faeflplt to I&*P Prnpfiernr,Patiriers ar ExeYxUe Cfimqrsare In-Juded,lonly cf=%tcxil all excluded or oertaln Nrine.m1officersexcludEd. This 69kiiijes Ihat thi insurance carrier indicated above in box"3"Insurps.thp Nisiness r6forenced afiove-ib box"Ia'to.r wo.7kers' compc nsa-U.bn under.tho NeV;York State Workers'Compensation. Law,(To use th.1.sform,New York(NY)must be lishid o6der RORY)3A on the,INFORMATION PACE of the workers'compensation insurance policy). The In!3urarme Carrier or Its licensed ap-nt will so,Id (his,Certilicato.ol insurance to,qhe entity listed above as the oertifcate.holder in box'2'- Wil;the carrier notif�vj�e certificate holder within,10 days of a polf b6idg-cancelled for nori-ppynientof premium oruethih 31)nays if tcy cancelled for any otti&reason or if the insured is omemyls e eliminated from the coverage Indicated on this certificate prior to the ervj c-F ,he policy effective period? DYES ENO This clerlifir-ato Is Issuod as a matter of information only and confers no right-upon the;certificate holder.This cerlifi6ate-dbes not amend, extepd ora-.tartho'cove,age afforded by1fie polfcylisted,nordoes,lt.conrerany tigntsor 6aspDrislWhIes bo'yond those ccrithined in the referenced pol cy. This certificate may be used as.*Vidonrie of nWorknrs'Compensation contract of insurance only while lhe-undedying pbllcyis til effect, Please Note:Upon cancellation of-the workers'compensation policy indicated on this form,if the business,continuos to be named on a,ptirrnit,.Iicense or contract issued by a c6rdetento holder,iho business must provide that ceitifficate holderWitb a now Certificbte of Workers'Compensation Coverage or other authorized proof.that the business;,ft-,complying with the mandatory coverage requirements of the Now York State Workers'Compensation Law; tinder penalty of perjury,I certify that I am an authafized.reprosentative or licensed agent 0 the insurance carrier referenced above and that the named insured has the'uovurdqu as depicted on this form. Aplirove8 by: I-IsD Ma-:Donald (Frira rvurne,or abi"n iz&J raWesa,18M or lar"saj agEnt or msur5nce carrorl AW,;!L-VVd by: 4/8/2021 (ssdn3t-jret (W I u) T!11!3:.ALCU un L ExeL UtlVe Telephoto Number of auttr-rized representative at licensed ager[of Insurance cartler, 732-504-2001 Please Note.,Only insurance carriers and their licensed agents are authorized to Issue Form C-105:2.Insurance brokers are ND authorized to issue it- C-'105.2 t- C-105.2(9-15) w.vvi.Sycb.ny,g ov 1 Workers' Compensation Law Section 57. Rostr'iction on issue,of permits and the entering Inta'contracts unless compensation Is secured. 1. A-he head of a state ar municipal department,board, cammis�iun or orlice authorized or required by law tc issue any permit for or'in connection with any work involving,the emp'oyment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duty subscribed by an insurance carrier is produced In.a form satlsfacion+to the chair. that compensation for all employees has been secured as provided by this chapter_ 14othing herein, however, shall be construed as creating any Ilabilib, �on the part of such state or municipal department„ hoard, commission or office to pay,any corfipensation to any such employee if so employed_ 2. The head of a state or municipal department, board, commission or pf ice authorized or required by law to enter into any contract,fpr or in connection v,1ith any work Involving the:employment of ernpluyees in a hazardous employment defined by tats chapter,notvAthstanding any general erspe:ial statute requiring oi"authorizing any such contract, shall not enter Into any such contrat:t uriless proof duly subscribed by an Insurance carrier is produced in a form sakisfoctory to the chair,that compensation for all employees has been secured as provided by ibis chapter. I i I E a I f i l f I I 0 1 I 7 E I I C-105.2 (9-15) REVERSE Ac® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYY1) `� 1 04/15/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald AAI CISR NAME: Brown&Brown Insurance of Delaware Valley PHONE (732)504-2001 FAX (732)504-2011 A/C No Ext: A1C No 2000 Midlantic Or,Suite 440 E-MAIL Imacdonald@bbdvins.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Mt Laurel NJ 08054 INSURERA: Colony Insurance Company 39993 INSURED Zurich American Insurance Company 16535 INSURER B: P y Pro Custom Solar LLC dba Momentum Solar INSURER C: Evanston Insurance Company 35378 Momentum Home Services Holdings LLC dba Momentum Home INSURER D: 45 Fairchild Ave,Suite B INSURER E: Plainview NY 11803 INSURER F: COVERAGES CERTIFICATE NUMBER: 21-22 NY Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLSUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMIDD MM/DD LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 F;�7� DAMAGE TO RENTE CLAIMS-MADE OCCUR PREMISES Ea occurrence $ 250,000 MED EXP(Any one person) $ 10,000 A PACES4257993 04/21/2021 04/21/2022 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY [g PRO 2,000,000 JECT LOC PRODUCTS $ OTHER: Professional Liability $ 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 2,000,000 Ea accident X ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED BAP 1873088-02 04/21/2021 04/21/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLALIAB I X OCCUR EACH OCCURRENCE $ 5,000,000 C X EXCESS LIAB CLAIMS-MADE MKLV4EFX102983 04/21/2021 04/21/2022 AGGREGATE $ 5,000,000 DED RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNERIEXECUTIVEF-1N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Excess Limits Clarification CGL$5M xs$1M C MKLV4EFX102983 04/21/2021 04/21/2022 Auto$4M xs$2M DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Middle Road AUTHORIZED REPRESENTATIVE Southold NY 11971 -- �- 01988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Additional Named Insureds Other Named Insureds Momentum Power Services LLC Momentum Roofing and Solar, LLC Momentum Roofing LLC OFAPPINF(02/2007) COPYRIGHT 2007,AMS SERVICES INC 1222 � ao�o SOW N SURVEY OF PROPERTY A T GREENPOR T �t�= TOWN OF SOU THOLD Nro PAS ' 1zgg� SUFFOLK COUNTY , N. Y. 1000-40-05-16 N 16'0►�.. E v SCALE : 1' - ZO' r~ N OCTOBER 6. 1Y96 SPE Z SEPT. 25,2002?oinoC lndhL 1 I.j T t0 I t �. zan' ) • CIL 9110, 37 to 1 rn -• O r' ' t^ l/1 CERTIFIED TO' N GARY BLASKO 6 �• �{ CARLA BLASKO COpITNENTAL CAPITAL CORP. '3 -4FCd:LltY TITLE INSURANCE COMPANY OF NEW YORK 2W TITLE NO. FNT 98IT50I i LOT NUMBERS REFER TO 'MAP OF FLEETFIELD" FILED °• IN THE SUFFOLK COUNTY Y CLERKS OFFICE AS MAP f NO. 1351. _ 0` NEW upt +Z� AREA 15,166 sq..ft. wZ50, An AL TE .'_« OR ADDIFION T7 TNI$ SURVEY fS A •1.JL 4Y1014 OF ¢sCr,.' '209 Or 7NE NEW •JRx 57ArE ED..fAr10N;aH ;TclM•.= jv r'_;Fc. F•v Ex:r=•T .:P SECTION 72D9-SL!BDIYISION 2. ALL CER7,F:CA7IONS 063( 7 7t5 •- 7.2i FAX(631) 70-5020 NE=E W., A-,FD FGP 7x7S.VAP AND COPIES THER£Cr ONLY IF 0. C. a^r 909 SA'i NAF CCP'ES BEAR THE IMPRESSES SEAL OF '-NE 51<RaE'JR 1230 T'PAiELEI'• >TREET Wr''E S •',A'JRE APPEARS NEREON 5L ''H'�L aJ. 11.'i "97' 98'33 47 HANWHA Q.PEAK DUO BLK ML-G10+40040OW MODULES PAIRED WITH momentum 47 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS SOLAR BRANCH CIRCUIT A ME MM EXISTING SQUARED 200A 13 MICRO-INVERTERS ENPHASE 80A AC PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B COMBINER BOX MAIN SERVICE PANEL 240 V 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 12 MICRO-INVERTERS W/ENVOY IQ STRUCTURA24,MOMENTUMS01-AR.COM L ENGINEERING BRANCH CIRCUIT C MAIN BREAKER:200A 12 MICRO-INVERTERS BRANCH CIRCUIT D CT =.w. NE SIDE 10 MICRO-INVERTERS + - + - + - HOT TAP !!OF NEW 89L AC DISCONNECT 200A �P�v vel DC: yO f 8 SQUARE-D SOLAR AC GRID 8 DISCONNECT E 80A 1 m LU ROOF 10A BREAKER POWER UTILITY JUNCTION (COMMUNICATION) 80AOCPD ?GROUND METER �� 093431 TERMINATION CAP 1 BOX 2A-D 20A BREAKER(A)(PV) 3 4 'OR INSTALLED ON 20A BREAKER(B)(PV) SSIDN 20A BREAKER(C)(PV) END OF CABLE 20A BREAKER(D)(PV) 30968 HAMILTON B vDSOUTH IkAl,U.,Cil 0)080 ENGINEERING LETTER ATTACHED HAS EFECIFICATONS FOR WIND AND LOAD GLNLATIONS FOR SOLAR INSTAlL1TON SPANS 8 ATTACHMENTS TO H LOCAL AND STATE BUILDING CODE COMPLIANCE WARNING THAT IT IS A VIOLATION OF THE IAW FOR Y PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED u NSeDARCHTrecT,TOALTERANNfMINANYwnY. 1.ALL CALCULATIONS FOR VOC,VMAX,IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75RC UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7.INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. -CUSTOM S0 DSAMOMEN JMEOIA 224 ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 3096 MAN LTON BL IIIJILDING 8,SONM PWNFIELD,M 07080 2.THE ENTIRE ARRAY IS BONDED ACCORDING TO(NEC 690.46-250.120 B.GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC INFORMATION 3.BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM.NO DC MODULES SHALL COMPLY WITH 250.64. BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT,COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS ZENAIDA HERNANDEZ-MS76546 DESIGN CURRENT THAN THE ONE SHOWN. BOX,DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. 15 MADISON STREET 4.THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE,INTERCONNECTION SHALL COMPLY WITH GREENPORT,NY 11944 89L LESS THAN lOFTTO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) 6314804157 JURISTICTION:SUFFOLK UTILITY:PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM Wire Tag Conduit Wire Qty Wire Wire Type Temp. Wire Temp. Conduit Derated Inverter NOC(A) NEC Design Ground Ground Wire INFORMATION Gauge Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty Correction Current(A) Size Type SYSTEM SIZE(DC):18.8 KW 1 OPEN AIR 2 12 AWG Trunk Cable 90"C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable SYSTEM SIZE(AC):13.63 KVA 47 MODULES:HANWHA Q.PEAK DUO BLK 2A 3/4-PVC 2 10 AWG THWN-2 90'C 40 0.96 0.7 26.88 13 1.21 1.25 19.66 08 AWG THWN-2400 71NVERTERS:ENPHASE IQ7PLUS-72-2-US 2B 3/4"PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 2C 3/4-PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 PROJECT INFORMATION 2D 3/4-PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 INITIAL DATE:7/22/3021DESIGNER:M REV: DATE: DESIGNER: 3 3/4-PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 REV: DATE: DESIGNER: 4 3/4-PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 ELECTRICAL PV-3 JUN 01 2022 � BUILDING DEPT TOWN OF SONUTHOLD OCCUPANCY OR USE IS UNLAWFUL APPROVED AS NOTED WITHOUT CERTIFICATE DATE: E_• -7-21 -B.P. S OF OCCUPANCY FEE: `� mej, BY: NOTIFY BUILDING DEPARTMENT AT 765-1802: 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION -.-TWO REQUIRED FOR POURED CONCRETE- 2. ROUGH - FRAMING & PLUMBING �.�L! W� I,_,lld r, AL; 3. INSULATION } O CON,. � 4. FINAL - CONSTRUCTION ;MUST NEW YORK STAT` & TQ'J,�� CODES BE COMPLETE FOR C.O. AS REQUIRED AND CONDITIONS OF ALL CONSTRUCTION SHALL MEET THE SOUTHOLD TOWN ZBA REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR SOUTHOLD TOWN PLANNING BOARD DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD TOWN TRUSTEES N.Y.S.DEC a MM alquMW RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE, 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP.ROOFS m ® d CONSIDERED FROM AN ANGLE OF MIN. 9.5' (12)TO MAX.45° (1Z)NOT TO EXCEED ° ° a e e momentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE Installation Item&Part Number MANUFACTURER. _ SOLAR 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE a ® � ® � e e Install Base and End clamp Slide In Mounting RT-APEX Base(RT3-00-AXBK) At— MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE �• � � PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR MANUFACTURER. `� " �`' ' •' ., ?, __,y. "�C.�"•D =� \��:� 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511h '' - 1�+ ,.s:�-�;%.��.'-=-„mac;>.! ;. RT-Apex Base;24 ea. (732)902-6224,MOMENTUMSOLAR.COM ��-w �`.� '.-1_ . SDS-60 Screws:48 ea. i fcy Atltlitp 60 RT-Butyl; e. 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH -- _-. _ STRUCTURAL ENGINEERING y :r_ -µ Middle clamp MANUFACTURERS PRINTED INSTRUCTIONS. :.„ ; �:; Mddle Clamp(RT3-02-UM-BK) f .j-'-�.FLiAZ.,[ r __ �� Midddl Floating Splice .�y � ,- ,� oa ng (RT3-02-UMFSBK) O � M'Wdle Clamp Splice(RT3-02-UMSBK) _1 i1NEW y � �� ., .:io'T�.�z^4•{':rJr. - •«a'+c�`a r ' ' •'^�.., � Middle clam 12 ea. .`tr_-.”"`_.,.%5. "".:•r•v'`'1 ` 1 End Clamp l (R13-02-UEF l - End [Clamp Splice(RT3-02-UESBK) ��_ - End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp r W PErr•1 W o`�� ��~^- End Clamp:12 ea. ,�°J' - • RT-APEX Skirt(RT3-03-SK80BL) rn Universal Clamping / Slide In Mounting SOA 09343 One Step Leveling / Integrated Flexible Flashing One step leveling ! '40F 1ONP\' RT-Apex Skirt 80inch;8 ea. ESSIO 4 114" Proven PV mounting since 1994 3" (108mm) Material0escn nen ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS psmm) —�� SAMUEL DEKYEM,P.E.NY LICENSE#093431(732)-902-6224 ICC G CSkins Anpolzed aluminum 3096B HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 AS PER ASCE 07-16. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C,&D AND ROOF �� eONas ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND �.'1 a j 3�Cr :J �^t I Hardware I Stand—steel WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, - ' ICC ESR 3595 I %� j Flexible Flashing RT Butyl(ICC ESR 35751 AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& Intertek --'` zs Year Umited warranty ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE RIDGE, OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. PAT PENDING COMPLIANCE.WARNING THAT IS HE OF THE LAW FOR 3 1!2" (90mm ANY PERSON,UNLESS ACTING UUNDERRTHE DIRERECTION OF A R0x ® LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. Ra 8 GUTTER GUTTER - e. o st b 2a oa° 0 © © YW CUSTOMER INFORMATION ® 2 ® RIDGE RIDGE ZENAIDA HERNANDEZ-MS76546 15 MADISON STREET GREENPORT, NY 11944 LU 6314804157 ® O 0 1URISTICTION:SUFFOLK UTILITY: PSEGLI 3i © GUTTER © GUTTER © STRUCTURAL STATEMENT: UTILITY ACCT#: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE UTILITY METER#: ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM PV SYSTEM ROOF ZONES 2 &3 ARE 48"FROM OUTTER ROOF EDGES, INCLUDING UPLIFT&SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC): 17.86 KW TABLE R301.2(1) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW SYSTEM SIZE(AC): 13.865 KVA YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERIA 47 MODULES: HANWHA Q.PEAK DUO BLK GROUND SNOW LOAD(LBS/SF) 25 OF THE TOWN. ML-G9+380 47 INVERTERS: ENPHASE IQ7PLUS-72-2-US SPEED (MPH) 130 TOPOGRAPHIC EFFECTS B PROJECT INFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 1966.95 LBS SPECIAL WIND REGION NO INITIAL DATE:7/22/2021 DESIGNER:RA TOTAL NUMBER OF ATTACHMENT POINTS 146 WIND BORNE DEBRIS ZONE 2 REV: DATE: DESIGNER: EIGHT PER ATTACHMENT POINT SEISMIC DESIGN CATEGORY C HANWHA Q.PEAK DUO BLK ML-G9+ 380 REV: DATE: DESIGNER: 380 WATT MODULE TOTAL SURFACE AREA OF PV MODULES 852.58 SQFT CLIMATE ZONE 4A 72�S4E D4TASHEETJ6tl COVER PAGE ISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT WIND EXPOSURE CATEGORY B PV- 1 ( 2) Z SCALE: 3/32 ' e V-0-1 ROOF MODULE COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN PORTRAITMAXSPAN ROOF AREA 1/2/3) (ROOF AREA 1/2/3) R1 19 31° 246° 84% 63/63/63 37/37/37 R2 9 31° 156° 85% momentum 63/63/63 37/37/37 R3 9 31° 336° 89% SOLAR 63/63/63 37/37/37 R4 10 31° 66° 1 76% 63/63/1, 37_/07 37 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ cu, R=_---\,\ r i STI�UCTUzR�►LDENGINEERING NEW y j 03 \ I ®1�-11 I co WALKWAY 03 omx Lij I ! I W Or / I I I �4A 09343 R2 // F �I I I R0FESSIo'�lP GUTTER-__ I I I I I ELECTRICAL EQUIPMENT SAMUELD KYEM,P.E.NY LICENSE#093431 732-902-6224 30968 HAMILTON BLVDSOUFH PLAINFIELD,N7 07080 I 1 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND 1'-3" I I I i /I I I MSP OM AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& I I I I I I ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE _ COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR I i I I I 1 1. ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A I 9 I I pLICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. I I1 I �l I nn x 0 0 Wi i ii p p CUSTOMER INFORMATION I I 1 IC/ ZENAIDA HERNANDEZ-MS76546 rn z 15 MADISON STREET GREENPORT, NY 11944 1'-3" —I' p 6314804157 GROUND ACCESS I I f Ir/ z I SYMBOL LEGEND (NP) m JURISTICTION:SUFFOLK UTILITY: PSEGLI / MSP MAIN SERVICE PANEL CHIMNEY UTILITY ACCT#: // //� UTILITY METER#: �tSP SUB-PANEL SKYLIGHT PV SYSTEM IIv^1I INFORMATION FIRE SETBACK OM UTILITY METER V� VENT �y SYSTEM SIZE DC : 17.86 KW 36" ROOF ACCESS) DISCONNECT (AC): (18" VENTILATION, - DRIVEWAY CB Ac COMBINER BOX/AC O PIPE VENT SYSTEM SIZE13.865 KVA DISC (TYP) 47 MODULES: HANWHA Q.PEAK DUO BLK UDC UTILITY DISCONNECT FAN ML-G9+380 ® 47 INVERTERS: ENPHASE IQ7PLUS-72-2-US LC LOAD CENTER SATELLITE DISH Id PROJECT INFORMATION N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS INITIAL DATE:7/22/2021 DESIGNER:RA REV: DATE: DESIGNER: _ CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: I' PF PERFORMANCE METER —• PITCH DIRECTION PANEL LAYOUT MODULE PV-2 47 HANWHA Q.PEAK DUO BLK ML-G9+380 38OW MODULES PAIRED WITH 47 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUIT 13 MICRO-INVERTERS ENPHASE 80A AC EXISTING SQUARE D 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B COMBINER BOX MAIN SERVICE PANEL 240 V 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ 12 MICRO-INVERTERS W/ENVOY IQ (732)902-6224,MOMENTUMSOLAR.COM BRANCH CIRCUIT C MAIN BREAKER:200A 12 MICRO-INVERTERS STRUCTURAL ENGINEERING BRANCH CIRCUIT D I CT Ea,a -LINE SIDE 10 MICRO-INVERTERS HOT TAP 89L AC DISCONNECT 200A g SQUARE-D SOLAR AC GRID CO Q '� g DISCONNECT 80A - W C7 ` i W f ISN GN - GNRBSl7S 2 ' r�u� ROOF 10A BREAKER _LPOWER UTILITY C7 JUNCTION (COMMUNICATION) 80A OCPD 'GROUND METER X9343 20A BREAKER(B)(PV) BOX 20A BREAKER(A)(PV) A TERMINATION CAP 1 2A-D 3 4 RQ C1Q� INSTALLED ON 20A BREAKER(C)(PV) FESS�� END OF CABLE 20A BREAKER(D)(PV) SAMUEL DEKYEM,P.E.NY LICENSE#09 431 732-902-6224 30968 HAMILTON BLVDSOUTH PLAINFIELD,N]07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOLAR DBA MOMENTUM SOLAR MARINELLO, 902-6224 ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 30 6REY HAMILTON BLVVD.732)BUILDING B,SOUTH PLAINFIELD,NJ 07080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER PARAGRAPH Q. THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC INFORMATION 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS ZENAIDA HERNANDEZ-MS76546 DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6, 690.17. 15 MADISON STREET 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH GREENPORT, NY 11944 89L LESS THAN 10FT TO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) 6314804157 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire INFORMATION Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC (A) Correction Current(A) Size Type SYSTEM SIZE(DC): 17.86 KW 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable SYSTEM SIZE(AC): 13.865 KVA 47 MODULES: HANWHA Q.PEAK DUO BLK 2A 1" PVC 2 10 AWG THWN-2 901C 40 0.96 0.7 26.88 13 1.21 1.25 19.66 08 AWG THWN-2 ML-G9+380 7 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2B 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 2C 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 PROJECT INFORMATION 2D 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 INITIAL DATE:7/22/2021 DESIGNER:RA REV: DATE: DESIGNER: 3 1" PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 REV: DATE: DESIGNER: 4 1" PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 ELECTRICAL PV-3 Samuel Dekyem Engineer-PE Samuel Dekyem Engineer-PE Pro Custom Solar LLC 732-902-6224 Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd July 8,2021 3096B Hamilton Blvd July 8,2021 South Plainfield,NJ 07080 South Plainfield,NJ 07080 Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria Zenaida Hernandez Structural Design Loads per ASCE 7-16 15 MADISON STREET GREENPORT,NY 11944 Dead Loads=10 psf+2.6 psf(new solar panels)=12.6 psf Roof Live Load=20 psf Dear Plan Reviewer: Ground Snow Load/Live Load=25 psf Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation Wind Load Calculation Criteria when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-16,Ch.30.4 Regarding the solar panel array installation on the above referenced project please note that an inspection was Design wind pressure determined by Eq.29.4-7: performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was Zone 1=-23.6 psf Roof Slope=31 degrees Roof Mean Height=15 ft conducted.There is adequate structural capacity for the installation of the array with the following recommendations: Zone 2=-30.7 psf Basic Wind Speed=130 mph 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x8"wood rafters @16"o.c. Zone 3=-34.6 psf Exposure=B spanning 127"with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf. overall to the roof.The existing structure is sufficient to support the new loads associated with the additional weight& Per section 2.4.1,ASD combo=D+0.6W: wind resistance.No additional structural support is required for the roof structure. Zone 1=2.6 psf+0.6(-23.6 psf)_-11.6 psf -- - Zone 2=2.6 psf+0.6(-30.7 pst)_-15.8 psf 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed Zone 3=2.6 psf+0.6(-34.6 psf)_-18.2 psf instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as Check Attachment to Wood Rafter specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter summary table below: Lag Screw Spacing: Lag Screw Tributary Area: Roof Type: Shingle Fastener Max Spacing(in.) Zone 1= 48"o.c.max Zone 1=(48"o.c.max)^2/144=16 SF Attachment System: "Ecofasten Solar"'Rock-Ii~'® Wind Zone I Wind Zone 2 Wind Zone 3 Zone 2= 32"o.c.max Zone 2=(32"o.c.max)^2/144=7.11 SF Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 32 32 Zone 3= 32"o.c.max Zone 3=(32"o.c.max)^2/144=7.11 SF embedment of 3"into the rafters 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. Lag Screw Forces: W=266lb/in(Table 12.2A,2015 NDS) 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Zone 1=11.6 psf x 16 SF=186 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) 5.All aspects of the installation shall comply with the 2020 Residential Code of New York State,ASCE-7-16,2017 Zone 2=15.8 psf x 7.11 SF=112 lb < W', OK Ct=1(Table 2.3.3,2015 NDS) National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 3=18.2 psf x 7.11 SF=129 lb < W', OK W'=W x embed x Cd x Ct law. W'=266 lb/in x 3 in.x 1.6 x 1=1276.8 lb 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. Digitally signed by Samuel Dekyem ( OL EQ y0 DN:cn=Samuel D E kyr q� Dekyem, o=Momentum Solar, Samuel Dekyem,P.E. 4 I w ou=Engineering, I UJ NY.Lie.No.0934312 email=sdekyem@mo s�o 09343 �� mentumhome.com, A9ope IO�P� C=US Date:2021.07.08 04:25:56-04'00' PLAN KEY SYSTEM INFORMATION THE RESPONSIBLE LICENSED DESIGN PROFESSIONAL SHALL PROVIDE A SIGNED AND SEALED LETTER CERTIFYING THE PV-1 COVER PAGE MODULE HANWHA Q.PEAK DUO BLK ML-G9+ 380 INSTALLATION WAS INSPECTED AND CONFORMS TO THE momentum PLANS AND REQUIREMENTS OF THE 2020 NYS BUILDING PV-1(2) COVER PAGE CONT. INVERTER ENPHASE IQ7PLUS-72-2-US CODE AND 2020'NYS RESIDENTIAL CODE. THIS INSPECTION SOLAR PV-2 PANEL LAYOUT AND CERTIFICATION LETTER SHALL BE PERFORMED AFTER RACKING ROOFTECH RT-APEX INSTALLATIONS ARE COMPLETED AND SHALL BE SUBMITTED PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-3 ELECTRICAL SYSTEM SIZE DC 17.86 KW TO THE BUILDING DEPARTMENT PRIOR TO SCHEDULING OF 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ PV-4 EQUIPMENT LABELS � FINAL INSPECTION. STRUCTURA24,MOMENTUMSOLAR.COM L ENGINEERING LOCATION 41.1119436,-72.3703525 THE UL CERTIFICATE OF ELECTRICAL INSPECTIONS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO QV- NE GENERAL NOTES: SCHEDULING OF FINAL INSPECTION. .<<C. y- '`Q. vel✓ D,, 1, 0 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS CIO FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 2020 NYS BUILDING CODE AND 2020 NYS RESIDENTIAL CODE, NEC 2017 AND ALL LOCAL CODES & r- ORDINANCES. o .W Z AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ON BOTH SIDES OF ZN � THE ROOF. NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36 INCHES (914 MM) WIDE, �� 09343 PROVIDEDSHALL BE LBUILDINGS. ONE PATHWAY PROVIDED ON THE STREET TOR DRIVEWAY SIDE F THE ROOF. FOR EACH PLANE A9�FESSIC) WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES WIDE (914 MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME SAMUEL DEKYEM,P.E.NY LICENSE#093431 732-902-6224 3096B BLVDSOUTHROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR ENGINEERING HAMILTONLETTER ATTACHED HIAS SPE,N3 07080 CIFICATIONS FOR WIND STRADDLING THE SAME AND ADJACENT ROOF PLANES. AND LOAD CALCULATIONS FOSOLAR INSTALLATION SPANS& - R ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. CUSTOMER WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR INFORMATION PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER BILL OF MATERIALS SYSTEMS. ZENAIDA HERNANDEZ-MS76546 MODULES 47 15 MADISON STREET ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENTINVERTERS 47 GREENPORT, NY 11944 INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A 6314804157 PLUMBING PERMIT AND INSPECTION. ROOFTECH BASE 159 JURISTICTION:SUFFOLK INVERTER PLACEMENT: MID CLAMP 91 UTILITY:PSEGLI END CLAMP 55 UTILITY ACCT#: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROLEND SPLICE 13 UTILITY METER#: LOCATED ON THE BACK SIDE OF EACH MODULE. END FLOATING SPLICE 14 PV SYSTEM BUILDING REVIEW NOTE: MID FLOATING SPLICE 26 INFORMATION TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR SKIRTS 16 SYSTEM SIZE(DC): 17.86 KW SYSTEM SIZE(AC): 13.865 KVA MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED ENPHASE COMBINER BOX 1 IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. 47 MODULES:HANWHA Q.PEAK DUO BLK THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT SOLAR AC DISCONNECT 1 ML-G9+380 47 INVERTERS:ENPHASE IQ7PLUS-72-2-US RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE 80A OCPD 1 HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S 125A LINE TAPS 2 PROJECT INFORMATION BELIEF AND INFORMATION, THE WORK IN DOCUMENT IS: INITIAL DATE:7/22/2021 DESIGNER:RA 1. ACCURATE REV: DATE: DESIGNER: 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE REV: DATE: DESIGNER: SUBMISSION. 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO COVER PAGE THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. PV_ 1 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP ROOFS CONSIDERED FROM AN ANGLE OF MIN. 9.5°(12)TO MAX.45°(12)NOT TO EXCEED _ eomomentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE MANUFACTURER. _ _ Installation Item&Part Number SOLAR 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE ® s ' ysieRT-APEX Base(RT3-00-AXBK) Install Base and End clamp Slide In Mounting _ MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THE �"I�\'!� � _ ,. ; MANUFACTURER. -'-''^.1'--r ,„ £ - _ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR '� � "� �� 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N] 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 - RT-Apex Base;24 ea. (732)902-6224,MOMENTUMSOLAR.COM I SD5-60 nalRT-wtyl;1248 ea. STRUCTURAL ENGINEERING 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH m`���� '._.�' ��,, �`--. Admtonal Rr-BuIyl;Iz ea. MANUFACTURERS PRINTED INSTRUCTIONS. Middle clamp S, =Q ddle C amp(RT3-02-UWBK) Middle IFloatiing Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) GO� NEFp L 'A Middle clamp;12 ea. End Clamp Splice (RT2-02-UEF 1 End Floaeng Splice(RT3-02-UEFSBK) R RI End Clamp Splice(RT3-02_UESBK) I Skirt and End Splice Skirt and End clamp _ r LU EX End Clamp;12 ea. m z RT-APEX Skirt_(RT3-03-SK800L) N Universal Clamping /Slide In Mounting OA 09343 One Step Leveling / Integrated Flexible Flashing One step leveling ! -Top ESSIONP� RT-Apex Skirt 801nch;8 ea. Proven PV mounting since 1994 3" (1oSmm) Material0escri non ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS (75mm) Base SAMUEL HAMILTON BL NYLICENSEI FIELD, 732 802-6224 ICC Clamps Anodized aluminum 3096B AS PER ASCE 07-16. RISK CATEGORY 11 TOPOGRAPHIC EFFECTS B,C,&D AND ROOF �I ` Ep� Skirt ENGIN HAMILTON TER ATTACHED D HASIELD,NF a�os6 c us a o o ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND Hardware Stainless steel AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, ICC ESR 3575 Intertek __ _ Flezlble Flashlne RT Butyl([CC ESR 35751 ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE RIDGE,OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. 25 Year Umi dWarrenty COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR 3 1/2" 90mm ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A " LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. • ® G GUTTER GUTTER .•• .. . . .. > o. o e •. 3 © 1 ® . d neY.m m Lij CUSTOMER ® T 0 w ��Q p j INFORMATION © 2 ® RIDGE RIDGE ® ® C7 ZENAIDA HERNANDEZ-MS76546 O3 ® ® Q©y T ® 15 MADISON STREET GREENPORT, NY 11944 W 6314804157 ® © O JURISTICTION:SUFFOLK UTILITY:PSEGLI 31 ® GUTTER ® GUTTER ® UTILITY ACCT#: STRUCTURAL STATEMENT: UTILITY METER#: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM PV SYSTEM ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, INCLUDING UPLIFT &SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC): 17.86 KW TABLE R301.2(1) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW SYSTEM SIZE(AC): 13.865 KVA YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERIA 47 MODULES: HANWHA Q.PEAK DUO BLK GROUND SNOW LOAD(LBS/SF) 25 OF THE TOWN. ML-G9+380 47 INVERTERS: ENPHASE IQ7PLUS-72-2-US SPEED (MPH) 130 TOPOGRAPHIC EFFECTS B PROJECT INFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 1966.95 LBS SPECIAL WIND REGION NO INITIAL DATE:7/22/2021 DESIGNER:RA TOTAL NUMBER OF ATTACHMENT POINTS 146 WIND BORNE DEBRIS ZONE 2 REV: DATE: DESIGNER: EIGHT PER ATTACHMENT POINT 13.47ZZbUZ73972SEISMIC DESIGN CATEGORY C HANWHA Q.PEAK DUO BLK ML-G9+ 380 REV: DATE: DESIGNER: 380 WATT MODULE TOTAL SURFACE AREA OF PV MODULES 852.58 SQFT CLIMATE ZONE 4A 72�SEE DATASHEETJ611 COVER PAGE ISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT WIND EXPOSURE CATEGORY B PV- 1 ( 2) V® 1 ( 2 SCALE: V-®" ROOF MODULE COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN PORTRAIT MAX SPAN ROOF AREA 1/2/3) (ROOF AREA 1/2/3) R1 19 31° 246° 84% 63/63/63 37/37/37 R2 9 31° 156° 85% 63/63/63 37/37/37 momentum R3 9 31° 336° 89% SOLAR 63/63/63 37/37/37 1'-1" R4 10 31° 66° 76% 63/63/6 37 37 t17 PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR R .l—R d ! !I __ 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 732 902-6224,MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING 3'-71" L DE,�yO,p COWALKWAY 171171 R4 W' i m ! W 2cs� 4'-0., —— -----I— •. 4___. II it CS , R 09343 QR2 � pFESS10� NP� ! L D ---- a! '�GU �'(... -.._I, ._-,I _.z.._„=.I .I__� .I„ _ -_I .• ELECTRICAL EQUIPMENT AM EL DEKT M, .E.NYO CE SE#F934 1NI 32-9 -6 4 S[EA i 1!�.f 30968 HAMIL ON BLVDS UTH PLAINFIELD, 07080 L _� _ I_ - ___I„ __ ___I ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND 1'-3” I -L. . ,_-I- I .I_ . _ _L __ I MSP OM AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE I �_ _ -_ I Q n COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR I, I m ANY PERSON,UNLESS ACTING UNDER THE DIRECRON OF A 3 D LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY.=1 -_.I _I-- I �n m M p �I CUSTOMER Iw).__. INFORMATION D O g ZENAIDA HERNANDEZ-MS76546 0 15 MADISON STREET M z GREENPORT, NY 11944 ,I-- GROUND ACCESS I:I__, ?.I�� .^I 6314804157 V-3-1 z SYMBOL LEGEND (TYP) n JURISTICTION:SUFFOLK % UTILITY: PSEGLI _�I� MSP MAIN SERVICE PANEL ® CHIMNEY UTILITY ACCT#: UTILITY METER#: ` SP SUB-PANEL Z SKYLIGHT PV SYSTEM FIRE SETBACK O UTILITY METER z VENT INFORMATION (18" VENTILATION, Q DRIVEWAY SYSTEM SIZE(DC): 17.86 KW 36" ROOF ACCESS (AC):Q DISCONNECT c6 Ac COMBINER BOX/AC O PIPE VENT SYSTEM SIZE 13.865 KVA • DISC (T'P) a Q 47 MODULES: HANWHA Q.PEAK DUO BLK UDC UTILITY DISCONNECT FAN ML-G9+380 r7 Q 4 Q 47 INVERTERS: ENPHASE IQ7PLUS-72-2-US G� d LC LOAD CENTER SATELLITE DISH U Q PROJECT INFORMATION Q QINITIAL DATE:7/22/2021 DESIGNER:RA NEMA 3R BOX W N3R /ENVOY-S ® FIRE SETBACKS • Q REV: DATE: DESIGNER: 4 , Q Q Q CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: L1 4 Q PF PERFORMANCE METER —. PITCH DIRECTION PANEL LAYOUT Q. E3 MODULE PV- 2 -- 47 HANWHA Q.PEAK DUO BLK ML-G9+380 38OW MODULES PAIRED WITH } 47 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS momentum SOLAR BRANCH CIRCUIT A EXISTING SQUARED 200A 13 MICRO-INVERTERS ENPHASE 80A AC PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR BRANCH CIRCUIT B COMBINER BOX MAIN SERVICE PANEL 240 V 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ 12 MICRO-INVERTERS W/ENVOY IQ (732)902-6224,MOMENTUMSOLAR.COM BRANCH CIRCUIT C MAIN BREAKER:200A STRUCTURAL ENGINEERING 12 MICRO-INVERTERS BRANCH CIRCUIT D CT E�o.,o INE SIDE 10 MICRO-INVERTERS HOT TAP OF NE 89L AC DISCONNECT 200A � veL �F►kV yy0� f L�� NIP - :0 S SQUARE-D SOLAR AC GRID *CO �Q� _T g DISCONNECT r CC 8OA m Lu W ROOF 10A BREAKERZN C? 1POWER UTILITY JUNCTION (COMMUNICATION) 80A OCPD 0A BREAKER(A) _y =GROUND METER �� �9343N TERMINATION CAP 1 BOX 2A-D ZOA BREAKER(B)(PV) 3 4 10 09343\ INSTALLED ON 20A BREAKER(C)(PV) END OF CABLE 20A BREAKER(D)(PV) SAMUEL DEKYEM,P.E.NY LICENSE#093431 732-902-6224 30960 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ' ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED 1.ALL CALCULATIONS.FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOLAR DBA MOMENTUM SOLAR JEFFREY MARINELLO,(732)92-6224 ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 3096 HAMILTON BLVD.BUILDING B,SOUTH PLAINFIELD,NJ 07080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC INFORMATION 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS ZENAIDA HERNANDEZ-MS76546 DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. 15 MADISON STREET 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH GREENPORT, NY 11944 89L LESS THAN 10FTTO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(B)AS PERMITTED BY 230.82(6) 6314804157 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire INFORMATION Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type SYSTEM SIZE(DC): 17.86 KW 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable SYSTEM SIZE(AC): 13.865 KVA 47 MODULES: HANWHA Q.PEAK DUO BILK 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 13 1.21 1.25 19.66 08 AWG THWN-2 ML-G9+380 7 INVERTERS: ENPHASE IQ7PLUS-72-2-US 26 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 2C 117 PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 12 1.21 1.25 18.15 08 AWG THWN-2 PROJECT INFORMATION 2D 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 INITIAL DATE:7/22/2021 DESIGNER:RA REV: DATE: DESIGNER: 3 1" PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 REV: DATE: DESIGNER: 4 1" PVC 3 04 AWG THWN-2 75°C 85 0.96 1 81.60 47 1.21 1.25 71.09 08 AWG THWN-2 ELECTRICAL PV-3 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY 0 • • e 12 AC CONDUITS ENCLOSURES/WALLS/ T_ - PARTITIONS/CEILINGS/FLOORS ` _ _ �=' " '4•-•'ri .. r' momentum OR NO MORE THAN 10' E "�.;r�`�_ +.� •�.�..•�-�• �,ci .`,,''Y�. ��,+a`� °�sst�ru• - :� SOLAR P14© • • • WARNING EQUI•RAPIDSHUTDOWN . - iIiiIS` •® 1 COMBINER BOX 1 AT ANY COMBINER BOX "� S ,' i e PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR +a.m- --^^" Qz_` r?• piz> 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,NJ • • • '• • ,- ?' ' fie.yam I (732)902-6224,MOMENTUMSOLAR.COM r '� � •r, ENGINEERING STRUCTURAL ENGIN X9.1 OF NES AWARNING.,� , , .,:Y,=�. I -� � - 1- C ELECTRICAL SHOCK HAZARD ~ TERMINALS ON BOTH LINE AND1 JUNCTION BOX 1 AT ANY JUNCTION BOX LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION lam; LU PV SYSTEM AC DISCONNECT WRATED AC ARN I N ; G • f ( p �r0 09343 ELECTRICAL SHOCK HAZARD ", r .- I a 90NP NOMINAL®' F TERMINALS ON BOTH LINE AND =-^ — ES SIO VOLTAGEAc LOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITION •„ - I i _—_ _ SAMUEL DEKYEM,P. .NY LLC NS # 431 73 - Z-6224 O 1 OF EACH AT FUSED AC '" �I'`` PI" - _—- -' 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 1 tY �� ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND ,&CAUTI ® DISCONNECT 1 AC DISCONNECT COMPLETE VOLTAGE AND - :J AND LOAD CALCULATIONS FOR SOLAR ATE BUILDING SPANS& .-::J I ATTACHMENTS U MEET LOCAL AND STATE BUILDING CODE _ COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR CURRENT VALUES ON z c� ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A POWERTO THIS SERVICE IS DISCONNECT LABEL LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ALSO SUPPLIED FROM e eF §OLARGENERATION AC SYSTEM DISCONNECT FOR SOLAR PVSYS.,TEM CUSTOMER O __E 1 PV METER 1 AT PV METER SOCKET AND _� g INFORMATION SOCKET ONE DIRECTORY PLACARD , ZENAIDA HERNANDEZ-MS76546 15 MADISON STREET , ,INzIll GREENPORT, NY 11944 1 UTILITY METER `i 6314804157 O �'DUAL POWER SOURCE� : � =- 1 AT UTILITY METER AND ONE a-��'-2 613 2' -�Ji JURISTICTION:SUFFOLK SECOND SOURCE IS, a .,�.^..�.'.. PHOTOVOLTAIC SYSTEMS DIRECTORY PLACARD UTILITY: PSEGLI UTILITY ACCT#: SOLAR PV SYSTEM EQUIPPED ' UTILITY METER#: WITH RAPID SHUTDOWN AWARN I-1 V G- ::. PV SYSTEM TURN RAPIDSHUTO 'DUAL POEROURCE; a 1 INTERCONNECTION YNFORMATIONSWITCHTOTHE•OFF PPOINT osmoN To SHUTDOWN W PV SYSTEM MDR DUCE ,;i, SECOND�;,SOURCE I$ ,�: , d _ SHOCKHAZARDINARRAY e F —. O--- --.—.--, SYSTEM SIZE(DC): 17.86 KW PHOTOVOLTAIC6SYSTEM'`_ - © 1 OF EACH AT BUILDING SYSTEM SIZE(AC): 13.865 KVA INTERCONNECTION POINT AND �- - f 47 MODULES: HANWHA Q.PEAK DUO BLK ONE DIRECTORY PLACARD ML-G9+380 WARNING INVERTEROUTPUTCONNECTION:, f 47 INVERTERS: ENPHASE IQ7PLUS-72-2-US s, .-.�. ,. -' 1 BACKFEED PANEL f_- DO NOTE RELQCATEvrTHISmoi,, aµ- 1 OVERCl7RRENT>DEVICE PROJECT INFORMATION INITIAL DATE:7/22/2021 DESIGNER:RA NOMINAL OPERATING AC VOLT'AGE-:240V -` REV: DATE: DESIGNER: NOMINALOPERATING AC FREQ60HZ O MAXIMUM '•WER:2 1 30VA REV: DATE: DESIGNER: MAXIMUM AC CURRENT:99 • _ &P 1 AC CURRENT PV MODULEAC PROTECTIONMODULES EQUIPMENT LABELS © BACKFEED PV-4 RT- PI : EX The most advanced . : . • PV Mounting System �� (, �..:Z:� •j-'..S �� �_r''"1": -- �_-- _=•-6.- _ - 'fir I },'�:U,2�r'3'i�r -.-�, .�t� '°cam ,;_.,;\'s'�:`r;--•`h-_r. .5, ,.;�. fg ti+ .`�v'y''''y'"'."�.�^,,.1 � t �1,.� .2: q�S 1.1r..`�.t`,v'•�,u`:�,34 F` �fr� ,}y}:i �.�rs.�.A ��'.',r_ a ..+cu'J'• -BT.�`�''�"A'�;>"�rr:F:')..;,r:'",�'^ RT- Universal Clamping / Slide In Mounting One Step Leveling / Integrated Flexible Flashing Proven PV mounting since 1994 ►►•: w, icc ljb- l/` c Us nceMeen ® � / ` 4srEo 7� ICC ESR 3575 Intertek Roof Tech The •. • for Waterproof • • Since 1994 RT-APEX The standard • rail-less PV • - Installation Item & Part Number Install Base and End clamp Slide In Mounting RT-APEX Base(RT3-00-AXBK) l RT-Apex Base;24 ea. SD5-60 Screws;48 ea. Additonal RT-Butyl; 12 ea. Middle clamp Middle Clamp(RT3-02-UM-BK) Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) i Middle clamp; 12 ea. End Clamp(RT3-02-UE-BK) `7, End Floating Splice(RT3-02-UEFSBK) = End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp s End Clamp; 12 ea. ® o RT-APEX Skirt(RT3-03-SK80BL) One step leveling ! RT-Apex Skirt 80inch;8 ea. 4 1/4" 311 �(108mm) Material Description Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235W-350W+ 235W-440-W,+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16V-48V 16V-60V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A. fl��� The high-powered smart grid-ready Overvoltageclass DCport II II DC part backfeed current 0 A 0 A Enphase IQ 7 Micro and Enphase IQ 7+Micro PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; IQ 7 and + dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V% 9 p 211-264 V 183-229V 211-264 V 183-229 V IQ Envoy",Enphase IQ Battery'",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'""monitoring and analysis software. Nominal frequency 47 6 60 6 Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 64 Power factor setting enabling Enphase to provide an industry-leading 1.0 1.0 Power factor(adjustable) 0.85leading...0.85lagging 0.85leading...0.85lagging warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V@208 V Peak efficiency 97.6% 97.6% 97.5% 9 7.3% PEC weighted efficiency 97.0% 97.0°i 97.0% 67.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(W%HXD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38 lbs) / l Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans /1 Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations _ Yes J Pollution degree PD3 +- Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor ---- — Optimized for high powered 60-cell and 72-cell*modules FEATURES o Communication Power Line Communication PLC • More than a million hours of testing _ (PLC) Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 0 disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21(UL 1741-SA) Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and wt frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. 1.U` No enforced DC/AC ratio.See the compatibility calculator at httos-Henphase.com/en-us/supoort/module-comr)atibility.2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.com EPHA$E. E P A$E ©2019 En hase Ener All rights reserved.All trademarks or brands used are the property of Enphase Ener Inc. P 9Y� 9 P P Y P 9Y. 2019-3-26 o :}. _ LG N@ N®2 ® 7 r LG345N1C-V5 I LG35ON1C-VS 6. >-_...-... _-. General Data Electrical Properties(STC*) LG345N1C-V5 LG350N1C-V5 Cell Praperties(MateriaVType) Monocrystalline/N-type Model LG345N1C-VS LG35ON1C-VS Cell Maker LG Maximum Power(Pmax) IWC 345 350 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) IV] 34.9 35.3 Numberof Busbbrs 12EA MPP Current(Impp) [A] 9.89 9.92 3 4 5 W 13 5 0 VU Module Dimensions(Lx W x H) 1,686mm x 1.016mm x 40 mra Open Circuit Voltage(Vac!S%) [v] 41.2 41.3 Weight _ 17.1 kg Short Circuit Current Qsc,±5%)- [A] 10.57 10.61 Glass(Material) _ Tempered Glass with AR Coating Module Efficiency [%] 20.1 20.4 The LG NeONO 2 is LG's best selling solar module,and is one of the mo Batksheac(Color) White Power Tolerance [%j 0-«3 powerful and versatile modules on the market today.Featuring LG's Ce Fmme(Material) Anodized Aluminium 'STC(Suerdard Test Conduxm):Irradiance 1000 W/m',cell temperature 25 T,AM 1.5 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes -Meas mra-tT lerance:!3% Technology,the LG NeONO 2 increases power output.New updates int Junction 1,000mm x 2EA an extended performance warranty to 90.08%to give customers high( eonnectar(Type/Maker) MC4/MC performance and reliability. Operating Conditions _ Certifications and Warranty Operati,97emperatum [°C] -40-+90 V wIEC 61215-1/-1-1/22 [V]016,IEC 61730-1/22016. Maximum System Voltage 1.000 D E G uL pg ` � \�ra \\/- UL 1703 Maximum Series Fuse Rating [A] 20 Cenifications ISO 9001.1SO 14001.ISO 50001 Mechanical Test I oad(Fmn,) [Pa/psf] 5,400/113 O01:2 12 Se Mechanical Testad S,40ear) [aced an 4.000/83.5 ® Salt Mist Corrosion Test IEC 6IEC 62 1 2 Severity 6 -MecTest L a d-Test,Lczd,S fety 000Pa based°n IEC 61215-2:2016 '! Test toad-Design load x Safety Factor(1.5) ® Ammonia Corrasion Test® TypeI(L1703)r Module Fre Performance Type NL Fire Rating Class C(UL 790,ULUORDORD C 1703) to Solar Module Product Warranty zs r Packaging Configuration Solar Module Output Warranty LinearWar2nty Numberof Modulesper pallet [EA) 25 r 'Improved:l st year 98%,from 2-24th year:0.33%/year down,after 25th year 90.08% Number of Modules per 40ft HQ Container (EA) 650 - - Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221 Temperature Characteristics Packaging Box Gross Weight [kg] 464 �• NMOT• ['c] 4233 Pmax [%/°C] -0.36 Vac [%/°C] -0.26 1. [%rc] 11D3 Dimensions(mm/inch) -NMOT(Nominal Module Operating Temperature),Irradiance 800 W/O,Ambient temperature 20-C, Wind speed 1 m/s,Spectrum AM 1.5 Features - _ Electrical Properties(NMOT) a ttbr.m�✓w,t Model LG345N1C-V5 LG35ON1C-VS - j Enhanced Performance Warranty Enhanced Product Warranty Maximum Power(Pmax) [w] 259 262 MPP Va[.go(Vmpp) M 32.8 33.2 s, LG NeON®2 has an enhanced LG has extended the warranty of the MPP Cument(Impp) [A] 7.89 7.91 _ performance warranty.After 25 f�444PPP__� NeONO 2 to 25 years including labor, Open Ci-it Voltage(Vac) [V] 36.8 38.9 years,LG NeONO 2 is guaranteed at I which is top level in the industry. shancinaitCurrent(I:t) [A] &49 e.52 least 90.08%of initial performance. I-V Curves 12.0 of - _ Better Performance on a Sunny Day '+`- Roof Aesthetics 10.0 6 s_1 `` n20.M LG NeON®2 now performs better onLG NeON°2 has been designed with Q aD sunny days,thanks to its improved �_.__ aesthetics in mind using thinner wires6otemperature coefficient. that appear all black at a distance.The LG NeON°2 can increase the aesthetic value 4.0of your home with a more modern design. 20 0.0 e a - - - - - - ------ -- --- - - - -- - - - - - - - - -- - - --- -- - 0.0 10.0 20.0 300 4010 � 6 When you go solar,ask for the brand you can trust: LG Solar voltage(V) About LG Electronics LGEleamnit:In Produttspeafiatiansaresubjecttochangewithoutnat,- ❑� '❑� �� Solar Business Division LG345-35ONiC-V5.pdf LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy sand n systems The company first embarked on s solar �� ®� 2000 Millbrook Drive energy source research program in 1985,supported by is Gr awd,ast experience in the semi-conductor,LCD.M.n.X ry and materials 2.NcON-2 2010,LG Solar successfully Lincolnshire,IL 60069 •� released us first Mono X°serves to the market,which is now dersh,le in i.countries The NeON°(previous MonoX°NeON),Ne0Nm2,NeON°2 BiFacial won the-IntersoUr AWARD"in 2013,2015 and 2016,which demonsVates LG's leadershp and innovation in the solar industry. Life's Good www.lg-5alarcom ©2019 LG Electronlrs.All rights reserved. J