Loading...
HomeMy WebLinkAbout47877-Z o��gtlFFOLK�oG Town of Southold 8/4/2022 y� P.O.Bog 1179 0 o • >� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43308 Date: 8/4/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 2240 Ruth Rd.,Mattituck SCTM#: 473889 SecBlock/Lot: 106.4-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/25/2022 pursuant to which Building Permit No. 47877 dated 5/31/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to DiPippo,Philip&Irene of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. - 47877 6/14/2022 PLUMBERS CERTIFICATION DATED A o iz gnature g�Ff TOWN OF SOUTHOLD BUILDING DEPARTMENT C, z TOWN CLERK'S OFFICE "o • � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47877 Date: 5/31/2022 Permission is hereby granted to: DiPippo, Philip 2240 Ruth Rd Mattituck, NY 11952 To: install generator as applied for. Must maintain a minimum of 25 feet from side yard lot line. At premises located at: 2240 Ruth Rd., Mattituck SCTM #473889 Sec/Block/Lot# 106.-1-5 Pursuant to application dated 4/25/2022 and approved by the Building Inspector. To expire on 11/30/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building Inspector pF SOU�yol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 , �Q sean.deviina—town.southold.ny.us Southold,NY 11971-0959 Q�yCOUNTV BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Philip DiPippo Address: 2240 Ruth Rd City:Mattituck St: NY zip: 11952 Building Permit#: 47$77 Section: 106 Block: 1 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Platinum East Electric License No: 34091 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Generator X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect 200A Switches 4'LED Exit Fixtures Pump Other Equipment: 22kW Generac Generator w/200A Transfer Switch Notes: Generator Inspector Signature: Date: June 14, 2022 S.Devlin-Cert Electrical Compliance Form 77 OFSOUTyolo V — —- 2, Z L -- * * TOWN OF SOUTHOLD BUILDING DEPT. `ycourm,N�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE 2 INSPECTOR �-�� FIELD INSPECTION REPORT DATE COMMENTS ,j b FOUNDATION(1ST) y ------------------------------------ ("d r� FOUNDATION (2ND) lv� Q ROUGH FRAMING& rz]y PLUMBING G' r(p v I Q INSULATION PER N.Y. STATE ENERGY CODE n FINAL - ADDITIONAL COMMENTS -1 - o0 Z S� r V Q' O H b H TOWN OF SOUTHOLD—BUILDING DEPARTMENT o� y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 htt-ps://www.southoldto=.gov Date Received APPLICATION FOR BUILDING PE MIT For Office Use Only ® E C� — � � E PERMIT N0. 47671 Building Inspector: APR 2.5 2022 Applications and forms must be filled out in their entirety. Incomplete BUILDING DEPT. applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: L� \�j 'z 'q 9 OWNER(S)6F PROPERTY: Name: M D Fo �ea C \ "� o SCTM # 1000- 10 _ Project Address: Q_A0 � 5Q Phone#: 5 W_ Email: Mailing Address: ()C/; �� I� CONTACT PERSON: Name: '& Mailing Address. 1 (w > d 1 Phone#: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name. Mailing Address: Phone#: Email: l C DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure [Addition ❑Alteration ❑Repair ❑Demolition Estimated Cast of Project: ❑Otherc� CX a kc—la Will the lot be re-graded? ❑Yes P(No Will excess fill be removed from premises? ❑Yes „<No 1 PROPERTY INFORMATION Existing use of property: �l r - 1`/1 t ` Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes,,WNo IF YES, PROVIDE A COPY. ,Ill Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by A.pter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing�ontract) above named, �k (S)he is the �� I�i��1 11 h'i�'l� '� 1 �,�� (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this itday of A0;I I ,20 ' ,2 � Notary Public Regina I..Cartselos Notary Pul-licr State of New York rao, ci.,CA6198908 PROPERTY OWNER AUTHORIZATION Qualified.in Suffolk County MyCOmmiti:iun CXpiresJanuary 5,2025(Where the applicant is not the owner) I, N�Y �t r'0 residing at O?d71"o kV-A( 6Q, do hereby authorize �, ( VGy to apply on my behalf to the Town of Southold Building Department for approval as described herein. v �� a-- ner's Signature Date / P N&& Print Owner's Name 2 rro��gVF UILDING DEPARTMENT- Electrical Inspector o54375 Main Road - PO Box 1179 WN OF SOUTHOLD own HallSouthold, New York 11971-0959 ® woo o Telephone (631) 765-1802 - FAX (631) 765-9502 1 ' -f rogerr(aDsoutholdtownny.gov — seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: L1 �t) Is Coo Company Name: V\A0U\n Ukd6w Electrician's Name: `&lh License No.: �40� `_m Elec. email: Elec. Phone No:(o - �5- �� ZI request dn email copy of �rtificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: P ` \ vh\fefvL k D Address: ('K— Cross Street: p Phone No.: 51L _ Bldg.Permit#: email: OCA Ol ( G \ l 1 M Tax Map District: 1000 Section: 0(-o Block: J Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): as�-� CLV- cC)CA(V " 2L&kC&V, Ty r-Sq-uare Footage: Circle All That Apply: Is job ready for inspection?: 1�5 YES ❑ NO ❑Rough In 21 Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION UILDING DEPARTMENT Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 r ev��ot�s0Ti1A'..`''' Southold, New York 11971-0959 °� Telephone (631) 765-1802 - FAX (631) 765-9502 "a,� r��i�r✓ rogerr&southoldtownny.gov seandCa�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: L1 l`j &-gq Company Name: `A\�A\).YY\ � ;� C )EA C 6 0 .\0 t I Electrician's Name: {�';�� License No.: �,��(` � ,-1��1 Elec. email: �� �� i1 u vd-�L�, L G , Elec. Phone No: �<<�qL0,1 request do email copy of C ;rtificate of Compliance Elec. Address.: JOB SITE INFORMA TION (All Information Required) Name: �t V` iD Address: C1� Cross Street: �.�> Phone No.: Bldg.Permit#: 14 -7 Pi-7 7 email: Tax Map District: 1000 Section: Block: ' t 'J Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): C -Nu, cuc- Cllb- , C60 Square,Footage: J� " Circle All That Apply: Is job ready for inspection?: tt YES ❑ NO ❑Rough In � Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size F11 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame R Pole Work done on Service? D Y F1N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT # Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven WAD Smokes DW Mini Carbon Micro Generator Combo Cookto p Transfer AC AH Hood Service Amps Have Used Special: f Comments. "- HEIDECNER LANG SNRVE1tNG c'O / ® E C F q IV/ E J a 5 ry° APR 2''.5 2119 c,0 i moo. P o� BUILDING DEP TOWN OFSOUTHOLE3 y6 ' \ Z ?2 DISTRICT 1000-SECTION 106.00 \ BLOCK 01.00-TAX LOT 005.000 / oo\ N/F PHILIP IRENE 0 \ LIBER 13077 6790-PAGE 679 \ AREA= 227,852 SQ.FT. \ OR 5.231 ACRES \ 9 \ �� O \ DxEPu¢ e�,s �FaE. Dru \ Ya¢EOuv��T [\IC CT9L—�^ WMGE cpv u. 0 04.x\ ua 01 \ \ \ \ ® \ �0 �w _.� S CEFffIFK.ATION ®�ummp0•m ry m00:�• / / wxxo.oxo wo m ' e 10 6o METERSPHILIP & IRENE DIPIPPO FFEEr "" «Po,"''n.,E"'° "`E°>o"° OMD AS—BUILT SURVEY'" sscnDN Loe-H10C%L-wr aGRAPHIC SCALE 1'=a0' "sem. my..r•i D3210 100-BLD I- �q�}m-ew YATITEGCC-SORT OP SOGIDIDID Pte • 0CoUNTY,NEW YORK PR VED AS NOTEED DATERAP � B:P:# l�� FEE: BY: NOTIFY BUILDING DEPARTMENT-,..AT 765-1802.8 _AM TO 4 PM FOR THE FOLLOWING INSPECTIONS:, 1. FOUNDATION - .TWO REQUIRED FOR POURED CONCRETE.. . - - rna(o 0 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONC.Tl:7!1''7'--')N MUST 1 r n BE COMPLETE.".�c.. _,. . ALL CONSTRUCT!:-.N. 'r--,ALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTH,.!. i QARD SoUrROLD-MV I USTEES OCCUPANCY-OR USE, IS UNLAWFUL WITHOUT CERTIFY OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED GENERAC° - �� GUARDIAN® SERIES _ 2®r22' / �4 kW Residential Standby Generators Air-Cooled Gas Engine OEM- Standby Power Rating INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power' Electrical Technology G007042-10,G007042-11,G007043-10,G007043-1 1(Aluminum-Bisque)-22 kW 60 Hz gy G007209-10,G007210-10(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution"con (English/Spanish/French/Portuguese) lln IK II ty/ �C • 200 amp service rated transfer switch available APR 2 .5 2022 • Electronic governor H f • Standard Wi-Fi°connectivity BUILDING DEPT. • System status&maintenance interval LED indicators TOWN OF SOUTHOLD • Sound attenuated enclosure' • Flexible fuel line connector • Natural gas or LP gas operation GENERAC — • 5 Year limited warranty • Listed and labeled for installation as close as 18 in(457 mm)to a structure.* *Must be located away from doors,windows,and fresh air intakes and in Produce shown with optional fascia we accordance with local codes. .1001 - -s or CUSTLED US �X UI � ""'�,. Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at tI%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. �IPROMISE �� `�' GENERAC® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications(excluding 20 kW units). • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 20/22/24 kW Features and Benefits Installation System _ • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(VVI-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Specifications Generator Model G007038-1 G007042-10 G007038-3 G007042-11 G007209-10 G007039-1 G007043-10 G007039-3 G007043-11 G007210-10 (20 kW) (22 KW) _ (20 k" (22 kW) - (24 kW) Rated maximum continuous power.capacity(LP) _ - - 20,000 Watts` --22,000 Watts" 20,000 Watts"-_ 22,000 Watts*-- 24,000 Watts'_ Rated maximum continuous power capacity-(NG) - -- 18,000 Watts` 19,500 Watts' 18,000 Watts' 19,500 Watts' 21,000 Watts' �Ratedvoltage ------- _ _ - - - -- --- ---- - ------------------ 240 _ i� Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 _Total Harmonic Distortion Main line circuit breaker - 90 amp 100 amp 90 amp 100 amp 100 amp Phase Number of rotor poles 2 -------------------- - Rated AC fiequency ----- -- --------- ------------ ------ - J Power factor - -- ---- 1.0 - - Battery requirement(not included) __ - __ - __ 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) - - - - 448/203 466/211 436/198 445/202 455/206 ,Dimens'iions(LXWXH)in/cm _-_- ' --__-- - -_-- - -_ _- --_-_ __--'_--- 48x25x29/121.9x63.5x73`7--___- -� Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" - - 67 - - 67 67 67 67 Sound out ut in dB(A)it 23 ft-(7 m)with enerator i_n Quiet-Test'"low-s eed exercise mode" - 55 - 57 - -55' - - 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Numbe r of cylinders - -__- -__---___ -_ - - _-J -- ------- - ---------------------------- - - Displacement 999 cc Cylinder block_ _ -__ _- -- - - - -�_- _Aluminum w/cast iron sleeve - ----- - Valve arrangement Overhead valve - -- - Ignition system Solid-state w(magneto - Governor system Electronic Compression ratio 9.5:1__ --- _ Starter - - 12 VDC Oil capacity including filter - -_ - --- _ - Approx.l.9 - - --- ---- --------- Operating rpm 'Fuel consumption- - - ---- ------ - - - -- --- - - --- ---- ------ -- ------------- - 3,600 Natural gas ft3/h1(2Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) 1/2 Load f Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane 113/hr(gal/hr)[Uhr] 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57] 1/2 Load l Full Load 130(3.56)[13.48] 142(3.90)[14.77] 136(3.74)[14.15] 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply 113/hr x 2500(LP)or 0/hr x 1000(NG).For Mega]oule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO _ _ T_ __ _- ---__ -- - -Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser., _--1 MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. - - - -- --- -- - - eT- - - - -- __- OFF - Stops unit.Power is removed.Control and charger still operate. - -_-; Ready to Run/Maintenance messages Standard - ----ndi6 -- -- -- - - ---- ------ ----- --------- ----------- �Engine run hours indication - - Standard _� -._-J --- --- -- e- --------- - - ----- ----- - - _-- -- - - --- - Programmable startdelay between 2-1500 seconds Standard(programmable by dealer only) _UtilityVoltage Loss/Return to Utility_adjustable(brownout setting)_ �__ ____- _ From T 40-171 V71-9-641-6 V --� Future Set Capable Exerciser/ cise Set Error warning - Standard i_R_k/harrWainten_ance-logs ___- - _ - - _--- 50 events each - - Engine start sequence - Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out - _ - Starter cannot re-engage until 5 sec after engine has stopped. l Smart BatteryCharger Standard I Charger Fault%Missing AC warning Low Battery/Battery Problem Protection and Battery Condition indication Standard 'Automatic Voltage Regulation with Over and Under VoltageProtectio_n _ J_ Standard Under-Frequency/Overload/Slepper Overcurrent Protection - Standard Safety Fused%Fuse Problem Protection Aut __ -__ ___ omatic Low Oil Pressure/High Oil Temperature Shutdown Standard i Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown High Engine Temperature Shutdown - - — Standard Internal Fault/Incorrect Wiring protection Common external fault capability Standard - Field upgradable firmware _ _ ___ _ ___ Standard ] Rating definitions-Optional Standby:Applicable for supplying backup power For duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating. (All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271). Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C). "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. GENERAC' 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features G007039-1,G007039.3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model G007043-10,G007043-11(22 kW) _ G007210-10(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles with Smart Management Modules(SMMs). Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. Voltage rating(VAC) 120/240,10 • Main breakers are rated for 80%continuous load. utility voltage monitor(fixed)* -Pick-up 80% • 2-pole,250 VAC contactors. -Dropout 65% • Service equipment rated,dual coil design. JReturnto Utility* Approx.13 sec ETL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. fLug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W, 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 1 "2 "' Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 DEPT" I--w2-� GENERAC' 20/22/24 kW Available Accessories Model# Product'T T Description !—^_----�--_-- --- ^'Y —_��- - jG007101-0 'Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 OF(-18°C).(Not nec- essary for use with AGM-style batteries). IfGO07102-0 ;Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF(-18°C). IG007103 1 '----IBreather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. �G005621 0 'Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be JContact Kit needed.Not compatible with 50 amp pre-wired switches. 6007027-0-Bisque Fascia Base Wrap Kit IThe fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured ! lappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. (6005703 0 Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. s The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. ;6006485 0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a i Generac automatic standby generator(oil not included). 1G007005 0 FWi Fj LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the I Monitor ILPtanlesfuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- p Itus alerts are available through a free application to notify users when the LP tank is in need of a refill. ;6007000-0(50 amp) Smart Management Module ISmart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- I13007006-0 I tncal loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce ;(100 amp) Ithe overall size and cost of the system. ;6007169-0-4G LTE 1iile Linker W Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using IG007170-0-Wi-FV ?Accessories fa smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Lls- flhemet lers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. jG067220-0-Bisque (Base Plug Kit 113ase plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured I i appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit 9 contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC 637.6 mm 1218.. [25.1 in] [48.01n1 G007038 696471074185 G007039 696471074192 O G607042 696471074208 G007043 696471074215 G007209 696471071511 7[28.6 Ini 6007210 696471084801 o a Jo 0 648 mm 1232 mm [25.5 In] [48.5 In, LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0000937814 Rev.E 03/15/2022