Loading...
HomeMy WebLinkAbout47088-Z �o�OSutF� p_ Town of Southold 8/14/2022 a y� P.O.Box 1179 0 53095 Main Rd goy o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43323 Date: 8/14/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 1300 Stars Rd.,East Marion SCTM#: 473889 Sec/Block/Lot: 31.4-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/25/2021 pursuant to which Building Permit No. 47088 dated 11/8/2021 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Golisz,Catherine i of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47088 1/20/2022 PLUMBERS CERTIFICATION DATED th ri Signature �ao�gUFFQ�,�coGy TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "oy • o��, SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47088 Date: 11/8/2021 Permission is hereby granted to: Golisz, Catherine 1300 Stars Rd East Marion, NY� 11939 To: install generator as applied for. At premises located at: 1300 Stars Rd., East Marion SCTM #473889 Sec/Block/Lot# 31.-4-1 Pursuant to application dated 10/25/2021 and approved by the Building Inspector. To expire on 5/10/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 Building or pF SOUryol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 0 • �o� sean.devlin(d-)town.southold.ny.us MUM BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Catherine Golisz Address: 1300 Stars Rd city:East Marion st: NY zip: 11939 Building Permit#: 47088 Section: 31 Block: 4 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement Generator X Commerical Outdoor X 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect El Switches 4'LED Exit Fixtures Pump Other Equipment: 14kW Generac Generator w/ 100A Whole House Transfer Switch Notes: Generator Inspector Signature: - Date: January 20, 2022 S.Devlin-Cert Electrical Compliance Form Of SOUIyOIo Li-7 0&&/- TOWN &&/.TOWN OF-SOUTHOLD BUILDING DEPT. 765-1802 a - INSPECTION [ ] FOUNDATION IST [ ] ROUGH'PLBG. [ ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 1� 'moi N'prt� �itf"�:�"te l L -- O /•� DATE INSPECTOR �o �aOF SOGTyo # # TOWN OF SOUTHOLD.BUILDING DEPT. `ycou765-1802 INSPECTION = [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ rSLATION/CAULKING U FRAMING /STRAPPING [ NAL **V_*+� [ -]--FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL.(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: IL �a ( ooyom,��D- &:IA- ra S�w ` t zm K 9A DATE °�� fib. I�a"� INSPECTOR $9/ SOUTyo� # # TOWN OF-SOUTHOLD BUILDING DEPT. cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL � �j�, ✓� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR FIELD:INSPECTION'R-PORT. 'DATE. COMMENTS CIQ FOUNDATION-(1ST) H FOUNDATION'(2ND). �. ROUGH FRAMING;& y '� PLUM I NG 1 INSULATION.PER N.Y. �7. STATE ENERGY CODE 16AA, 15 4b 40 FINAL ADDITIONAL COMIYIENTS 0 r fFat��oGy r -��rFOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 o a�� Telephone(631)765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: D E ((a � � W E Applications and forms,must.be filled out'in their entirety.Incomplete OCT Z 5 ZOZ1 applications will not be accepted, Where the Applicant is not the owner,an.; Owner's Authorization form(Page 2)shall be completed. BUILDING DEPT. TOWN OF SOUTHOLD Date: OWNER(S)OF PROPERTY: Name: SCTM#loon- G�i--{iA-,.r-I e- Go 1.esz, _ 3 i L4- 1 Project Address: pp S LIST- MQ-I'1: Phone#: I �P L/-9 a- I Email: �O 1`2eMrAA4� Q� � &14-f.01161 Mailing Address: CONTACT PERSON: Name: 1 MailingAddress: Phone#: 1 C1_ 7 C( ( Emal �y DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR'I N FORMATION e Name: Mailing Address: ® Phone#: : mailS S SIG- 12— ( - �e 6 LJ DESCRIPTION OF PROPOSED•CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: tether I y A(iy CO en e rC 4 / $ Joe Will the lot be re-graded? ❑Yes EAo- Will excess fill be removed from premises? ❑Yes M44-0-- 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ONO IF YES, PROVIDE A COPY. Check Box After Reading:,The owner/contractor/design professional is responsible for all drainage and storm water'issues as provided by ' Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone` Ordinance of the Town of Southold,Suffolk,County,New York and other applicable.Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section.210.45 of the New York State Penal,Law. _ Application Submitted By(pri ame): �o s ^�'`i ` l�uthorized Agent ❑Owner Signature of Applicant: ate: Mafia E.Thomas NOTARY PUTijL1r,STATE OF NEW YORK STATE OF NEW YORK) Registrawri No OITH615682 'eftc.•'t:County I COUNTY OF w �O I'`) Cornmissioa BXj,IIes Decemb0r 4,200 J7*,.e,,L being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Con (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Aday of 201 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, CAJ(A-e-(-tile- Go ck's Z- residing at Boo Cv+arS P-oa.C(l C4+ Mwiy, �,q do hereby authorize �r,�.er 4' S"kL) UL to apply on my behalf to the Town of Southold Building Department for approval as described herein. t , �o a Owner's Signature bate Print Owner's Name, 2 ®SUFFQ(�.c® BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ® Town Hall Annex- 54375 Main Road - PO Box 1179 az Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cDsoutholdtownny.gov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 10/25/21 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191 ❑I request an email copy of Certificate of Compliance Elec. Address.: PO Box 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: Catherine Golisz Address: 1300 Stars Road East Marion Cross Street: Phone No.: 516-459-1721 Bldg.Permit#: email: noreenmyers1012@gmail.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 14KW Generac generator with 100 amp service rated transfer switch Square Footage: Circle All That Apply: Is job ready for inspection?: YES E] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES FV-] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION pvl �('I G �0 1 �FF04 BUILDING DEPARTMENT- Electrical Inspector ® G� TOWN OF SOUTHOLD c, Town Hall Annex- 54375 Main Road - PO Box 1179 ,� 'p►° Southold, New York 11971-0959 $ ': Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov •- sea ndasoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail information Required) Date: 10/25/21 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191 ❑I request an email copy of Certificate of Compliance Elec. Address.: PO Box 512.Cutchogue NY 11935 JOB SITE INFORMATION (AII Information Required) Name: Catherine Golisz Address: 1300 Stars Road East Marion Cross Street: Phone No.: 516-459-1721' Bldg.Permit#: O email: noreenmyers101,2@gmaii.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 14KW Generac generator with 100 amp service rated transfer switch Square Footage: Circle All That Apply: Is job ready for inspection?: YES❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES FV-�NO Issued On Temp Information: (All information required) Service Size❑1 PhF-]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 n2 F1 H Frame D Pole Work done on Service? OY nN Additional Information: PAYMENT DUE WITH APPLICATION G J IV vi DATE(MMIDD/YYYY) ACOR& CERTIFICATE OF LIABILITY INSURANCEF L.� 06/21/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME CT Josh Mitchell Freedom Coverage Corp PHONE fAIC.No. 631)709-2777 a Ne: 80 Orville Dr Suite 100 EMINOARESS: Josh@FreedomCoverageNY.com Bohemia,NY 11716 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: Midvale Indemilly Company 27138 INSURED INSURERS: Employers insurance 11512 Peconic Power Systems LLC INSURERC: 315 Commerce Rd INSURER D: Cutchogue,NY 11935 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166-77552 REVISION NUMBER: 4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL 9UBR POLICY NUMBER M�oY EFF M�Dr EXP LIMITS LTR A X COMMERCIAL GENERAL LIABILITY GLP1092481 05128/2021 05/28/2022 EACH OCCURRENCE $ 110 0000 CLAIMS-MADE FRI OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person $ 5,000 PERSONAL 8 ADV INJURY $ 11000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 1,000,000 X POLICY E JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per,person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA UAB OCCUR EACH OCCURRENCE $ EXCESS LIAR HCLAIMS-MADE AGGREGATE $ DED I I RETENTION $ B WORKERS COMPENSATIONEIG4706645 0210312021 02103/2022 STATUTE X ETM AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETORIPARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED4 N f A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION Town of Southhold- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Annex 54375 Main Road P.O. BOX 1179 AUTHORIZED REPRESENTATIVE Southold,NY 11971 AL2 JCM ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Printed by JCM on June 21,2021 at 09:01AM -'� - - - r-.�_ . ,�':,.' - - �,S �--. C. - _ . . ,. ,. ,. . . .'' • _ :` a, ;_ ! : . , 4 < `, 6 - .. 3 _ _ } t q ! $$ P '. f S . _ . .� _ y* ^( ] j '♦ _ - x ' N, r - - - - I� Y •. , ' �i ... t,':" ` . . ., , -, . ., z ;. -' $>, . 4. s� 'i E x ]..�' ..q_ ��s. . "'7 4.� .. ,'� �] moi. ..•` � „;- + - La+,s - .. , 1' '.'' '::�4 e , - - - - . " . i , ,.` < . W {L .+ qq lel{°4'.- -. - '1 '.�� RJ i ., °ms t b �', �. - T . ?k �• r t. `: 4 p® l 'f! -I - '^ R! r:: y�r �1 1 r^ t i ��y4.4 �s/� -`1 'c �/� - - c #• r f e '4 - _ 1'� , V 8T 3 /'��: .� c .'i d 1 ' Y'-"yam" - �'�(' Y j \. l,/c �'rt+:,, rN '� Ay y :� q `.' T x ` k �. = } Aa A. .- - - , - w rYs ti _ t X911 irr I `y II +'i♦',^ T M Y 8� a - - te. 1<. �4ai ' ll33 s' ^1: ,k 4 rtWt' f# .. i ,.i. - - v, n. _ - S . I• f : . . ti . 'i a'. ::i, wy�� %a j�A ..'^ d4 1' v ,� p { S - `r S- i G _ F` •r' `�. . ~' J " V i£'- 1 �;: M J } f i..A Y• kY - e{' 11' �a a , •:2'r '4 �':SY.i f '-4~ , - �': C fi fi a } M, 4 i J gyp, ♦,.av - `a , _ _ $g 3' ' �-s of - <. ;'{ .' 4 L �Y�' R x r� -"L,� /9k _ a; f + _ f' <'e` , R ' ..,+ F - , 4.;: k `r» 9S - i?: est" x h�. t:; J�:'i< �fr.. �w. M e J': _ ,. _ Yrsry j.e _ -n _ t .Y - Y• - 'a?V A -T ''f< .ry l Y! �&.5 Y .43 r'P'> ,_ t ;, /`' `1 ` v � �f •'... .a, 'Y' •4e - - gid""'' r, :Wa,. .N /+l�J1V. l "$ ' l• i, S Ay 4« y :?r« i. 3w f 4' +`` < .. ., - _ .. . e .-. ,.. , :v }- F+.fit- 'at I ire j - .},Ia., y'.'' '� 1 .1.� M1' �: 'y t a •:*� 'At� 3,� '. Y f, l vim, 4`.,F r�1 :t 1• if fK , x. y. a - ,. aS .I - .^ , .I` - '1 V- J. , A" - .A 4.' ,,� Pd + � ( 9�' Ii. i< ', ds yamy[ tl _ W m d £" l -�t �J J - :' s-' -1. v V X � YCt��y; ;J y� J. 1 4 Y > t. i a - 3 'j {r { U1 5 „a.. J.' c >'. moi' l-'` 1 `�,y ��Y.M1 _ - .aa. - r fila, r,� �C �i, } - .. =St • , :"'is W) La. . t',frM1.r- - Vd tin 3.. y e �J{w'' 7 r1 �i -, r .5.:J w cT ....r .: 1•x'. M1_ . x a: J Y• i'"� i`. yr�q,�t, rT'''' k 'i- t - . ' ti t .H �i "ur �r�+'� g u` 7 - ., .. Y ;n .1: - - - . }�, . - .ate , y T , vj u _ .1. - - - - %r fi .II. i {. - i k\. �• - x •, '' _ , F ,t�6:'1'!rt f'. ",=s-.:,.: xx�aw+.ti�'Y •saa":_+r+Rt:�ta6 `s z L 'r- Ji = - •�'� i , f" -. ro ie%f �*� l ,1. ty �. i. [ - - •kay l� .. 4 aJp - i`S` is 4` (`' x"1 9 ♦' >-F`' Y r,. •r #/' - _^;' '� i+ Y Y + 3ot.N ' T '' `" l• x' <' s. r _ .' f� '], -�1,e - - ( i` l: (r t ^+Lwmsaumr_ t' , .e♦.-fir 1 - +,ryww+ , {L//, n,,S,C +YMwnym.Ipeae.ps A 'd" 'dt - Y. t`5 - \ .1' 'd �I _ - =�i i b 1 :F `! 1t '4' X a L., Y, r rr`. 'xC �; 5 - > r' ♦,� s =J. :,' � �q ee t 1 4 I'uu�+ .td' Y" '`4'' �,ea AL 5 ?il•6!f' :a� i 4.Pt 1i Le�y,T c] V U - mill+ ,_ _ _� - _ - , r' ,c' _ �y :t p li M. '• .@i ,'i _ �1�r+ d x v� E 'hr , L' �'n - w' S y - ,1 S C , - _ - - - 'y h (t A 8 d+ L 'M`t 1. j( .. ,, AM^ },' >. '1� /e:� r saw'+-d1• - -� ` MY_' west - �,ice '1, t"7°,` web&. ndeRr'e'a'n--..w'% ':.Y-,.' ��} •�`�.' ,. .N' .1 d``r""is..»_+,.,r+vciw..<✓ �,�..-�,�.•,y^ ,`L- enw+-�::++ls„a.� V C't - ;} !! /��r C �, pr. ' . P Y^r e K= 1�'t'�J Ww Sd P SA tAY _ �,~.. x t� y +. f- 7lrt_ lY TL2 Q 1;� . £1? 52 O �,a.t S � R ih�C �. t'� 4 �+ At m '�r 1, l t' i a �': :',' #; j EOSS: .RC S`tAl�'Vfilt1� , .CC i� _4iEd3 /�ww�y a�k r p�� t W�/' la " �' 2;+ ". " `." ,firms . A ., n`' . n' r . _. r3 3 r - i h 4 , l 4t41 -€£ C P bt. .� L� i ��C �Rf- tL'�R S t £ € �: t N 4� {1 ,IY, p„ �, r E'Y f" `r.a# {.. A. ` { �- j. C1i1 Tt1 TNS C1 fftJfi 'ifit t=T1{E`5�1r f7' '�" y_ .a _ 4 PkgtAC! h.[II_ 3 ,�15'E$WrCT 'H w�� � � II - -a - ' -.. 'IL ati y�cu 'QIP _ - j','' - _ _ y f` c i : � .- , y" >� S + y - # 1 .,X ` " '14 _ _ E h G t~' i �JTiQ1P i.1 TEG hR.�a¢Ct1i,,MTaLi - � S '4s}. S" lL e F- , 7 ` F F.. to� - ..t.i�. �� ��\� - <X' }i j .t' 'i yep; `Yq e'd r�itc+�Yxa5 Ff M14': ' fx,,, .. 3, 'ca,T�4s, , IS i 3♦, # e " '; « - ? rig,'.,, a '"^'''T2'r, Me 7't'b�lhslckL - 'i'1 f{' -r ~T l�'a`�. 3IC. �.`i 'l '. _ ¢�� w�r :r p.7A �• .ge �, „pN'"l� '•d r Jvv', .aY' 1 ' '' =. `*W: _ -.I <.Y' •i.we.- - , - t ,4J :� .. lII ., ix Y "y�.i-!";" Why," <; - Y*A t VED AS NOTED ENERAC° DATE:APPRB P.# .e FEE:-. � 60 BY: GUARDIAN° SERIES 105h8WNOTIFY :BUILDING DEPARTMENT 765-1802,,.'8'AM TO 4 PM FOR Jesidential Standby Generators FOLLOWING INSPECTIONS: Air-Cooled Gas Engine 1- FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH ' 3. INSULATION Standby Power Rating INCLUDES: 4. FINAL - CONSTRUCTION MUSTG007171-0,G007172-0(Aluminum-Bisque)—10 kW 60 Hz • True Power'"' Electrical Technology a I'IBE COMPLETE FOR 13®7223-0,G007224-0,G007225-0(Aluminum-Bisque)—14 kW 60 Hz • Two-line multilingual digital LCD Evo&Q n1GQM;9 1CTION SHALL MEEfO?T@6-0,G007228-0(Aluminum-Bisque)—18 kW 60 Hz (English/Spanish/French/PortuguesepEQUIREMENTS OF THE CODES OF NEW • Two transfer switch options availableYORK STATE. NOT RESPONSIBLE FOR 100 amp 16 circuit switch or DESIGN OR CONSTRUCTION ERRORS. 200 amp service rated smart switch • Electronic governor Standard Wi-F16 connectivity n tc"'U ANCY 0 .:. • System status&maintenance interval LED ia 1i • Sound attenuated enclosure USE IS 1 UNLAIN llLa34 V • Flexible fuel line connector f r ` • Natural gas or LP gas operation WITHOUT CER 1Ff GENERAL • 5 Year limited warranty OF OCCU PAN • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a T'G structure.* e E I Y us or c ST us QU' n L� *Must be located away from doors, windows,and fresh air ria intakes and in accordance with local codes. ,. LISTED "s Note:CEfL or CUL certification only applies to unbundled units and units packaged with limited Constructionlndustryl973—DoC-204-13204-01-01—Rev9.pdf circuit switches.Units packaged with the Smart Switch are ErL or UL certified in the USA only. * Il tl l uS� fYlar Aa-frt 1414nQ LLIL �be' FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most.The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation at±1%. O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAL ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®WI-FI CONNECTIVITY:FREE with select Guardian Series home COMPLY WITH ALL CODES OF standby generators, Mobile Link Wi-Fi allows users to monitor the status of the NEW YORK STATE & TOWN CODES generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. AS REQUIRED AND CONDITIONS OF Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. NG BOARD RUSTEESE6ECTRICAL wGENERAC OLD TOWN DEINSPECTION REQUIRED PROMISE \w GENERAC® 10/14/18 kW Features and Benefits Engine CD • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution- Controls • AUTO/MANUAUOFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 10/14/18 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 10/14/18 kW Specifications Generator Model G007171.0,6007172-0 6007223.0,6007224.0, G007226.0,G007228-0 (10 kW) 6007225.0(14 kW) (18 kW) Rated maximum continuous power capacity(LP) 10,6do Watts' 14,000 Wats" 18,000 Watts" Rated maximum continuous power capacity(NG) 9,000 Watts' 14,000 Watts' 17,000 Watts" Rated voltage _.. _. ._ 240 _ Rated maximum continuous load current-240 volts(LP/NG) 41.7/37.5 58.3/58.3 ,TotalHarmonlcoistdtticn _.. ._ -__.... _. ._. . _._ .. Lessthan5% Main iine circuit breaker45 Amp 60 Amp 80 Amp Phase 71, Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery,requiremenf(nofincludedj_ V 12 Volts,Group.25R 540 CCA Minimum or Group 35_AGM 65.0 CCA_-Minimum _- - Unit weight(lb/kg) 338/153 385/175 420/191 Dimensions(L x W x Hj iri/cm 48 x 25 x 29/121.9 z 63_.5 x 73.7 - Sound output in dB(A)at 23 it(7 m)with generator operating at normal'load*'* 61 65 65 Sound outpuf lh'dB,(A)at 23 it(7 m)with genera_tar in Quiet-Test"low-speed exerclse mode"- 5755 55 Exercise duratlon 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Number of cylinders.. . 1 2 Displacement 46.0 cc 816 cc Cylinder block V Numinum w/cast Iran sleeve Valve arrangement Overhead vatve Litter type - "Solid - - - Hydraulic Ignition system Solid-state w/magneto _ Governor system Electronic Compression ratio 9.5:1 Starter-_ ......, _. ....... . `12 VDC Oil capacity including filter Approx.1.1 qt/1.0 L Approx.2.2 qt/2.1 L Operating rpm _ ._ 3,600 Fuel consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 101(2.86) 195(5.52) 169(4.79) Full Load 127(3.60) 256(7.25) 247(6.99) Liquid Propane ft3/hr(gal/hr)[L/hr] 1/2 Load 36(0.97)[3.66] 65(1.81)[6.87] 62(1.70)[6.45] Full Load 54(1.48)[5.62] 112(3.07)[11.61] 110(3.02)[11.44] Note:Fuel pipe must be stied for 611 16d.Required fuel pressure to generator fuel inlet at all load ranges-8.5-TO idw,ater column(0.87-1,74 kPa)forNG,10-12 in water column(2.49-2.99 kPa)for LP 'gas.For BTU content,multiply tt3/hr x 2,500(LP)or ft3/hr x 1,000(NG).For Megajoule content,mulOply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain[ext multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops_unit.Power is removed.Control and charger still operate_. fReady_ta RuNMaintenance mes§ages Standard Engine run hours indication Standard Programmable startdelay between 2-1500 seconds Standard(programmable by dealer only) - Utility voltage loss/Return to utility adjustable(brownout setting) From 140-171 V/190-216 V Future set capable exerciser/Exercise set error warning _-- ""- - _. __.__._ __.._. Standard ten -- -- Rurmarm/Mainance logs 50 events each Enginestart sequence Cyclic cranking:16 sec on,7 sec rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery charger - - - - _ - - Standard Charger Fault/Missing AC Warning Standard Law Battery/Battery Problem Profection and Baltery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown J Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal-Fault/Incorrect Wlring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability Is available for this rating.(AEI ratings in accordance with BS5514,IS03046,UL2200,and DIN6271). "Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level and approximately 1%for each 10'F(6°C)above 60°F(16°C).'"Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. GENERAC" 10/14/18 kW Switch Options Limited Circuits Switch Features Model 0007172-0 0007224-0 (10 kW) (14 kW) • 16 space,24 circuit.Breakers not included. No.of poles 2 • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) 100 • Rated for all classes of load,100%equipment rated,both inductive and ;Voltage ratirig(VAC) - " ' 120 GENERAC 10/14/18 kW Available Accessories ------------ -—-—-- Model# Product Description ;Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell bat� G005819-0 26R Wet Cell Battery tery for use with all air-cooled standby product(excluding PowerPacto). G0071011-0 Battery Pad Warmer }The pad warmer rests under the battery.Recommended for use If the temperature regularly falls below 0*F(-18 I *C).(Not necessary for use with AGM-style batteries). 13007102-0 ;Oil Warmer 011 warmer slips`directly 6Wr_fWoil iiiii-Recommended for use if the temperature regularly falls below-0­_*_F_(-_1_8'°C). ,6 of 6 G007103-1 Breather Warmer The breather warmer is for use In extreme cold weather applications.For use with Evolution controllers only in I I climates where heavy icing occurs. Auxiliary Transfer Switch The--auxiliary— -i—ra,ns'ie"i's"wit-c h--contact kit-allows--the transfer switch-- 'to lock out—i single large-electrical load you—may" `;GO05621-0 Contact Kit i not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled'generators.This offers asleek,con-� G007027-0-Bisque =Fascia Base Wrap Kit ';toured appearance as well as offering protection from rodents and Insects by covering the lifting holes located in the base. ........... ------- If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future, G005703-0-Bisque x Touch-Up Paint Kit j corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator en- closure. 13006482-0 Generac's scheduled maintenance kits provide all the hems necessary to perform complete routine maintenance --'fd A )Scheduled Maintenance Kit i ,, G007216-0—14 18 kW on a Generac automatic standby generator(oil not included). 'The Wi-Fii enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring 13007005-0 �'Wi-Fl LP Fuel Level Monitor }the LP tank's fuel level is an Important step In verifying the generator is ready to run during an unexpected powerl failure.Status alerts are available through a free application to nofdy users when the LP tank is in need of a refill. 13007000-0(50 amps) ` Smart Management Modules(SMM)are used to optimize the performance of a standby generator.it manages G007006-0(1100 amps) 1 Smart Management Module large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using! i SMM's can reduce the overall size and cost of the system. 'The Mobile Link family of Cellular Accessories allow users to monitor the status of the generator from anywhere 13007170-0(WI-FUEther- Mobile G007169-0(413 LTE) Link O Cellular in the world,using a smarlphone,tablet,or PC.Easily access information such as the current operating status and I iAccessories maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proacj net) Aive service.With Mobile Link,users are taken care of before the next power outage. Dimensions & UPCs 1218 man 637 [25.1 148.0 In) Model UPC C2511 In] G007171-0 696471074680 0 G007172-0 696471074673 G007223-0 696471082548 727.2 mm 99�� [21.6 In] 11519�� G007224-0 696471082555 NE9 11619�� - G007225-0 696471082562 G007226-0 696471082579 u o 0 0 G007228-0 696471082586 L 648 rn. r1232 mm 25.6 In] [48.5 In] LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See Installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC® Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,WI 53189 - generac.com N - @2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000973374 Rev.A 10/22/2020