HomeMy WebLinkAbout48074-Z Town of Southold 7/18/2022 P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43274 Date: 7/18/2022 THIS CERTIFIES that the building ALTERATION Location of Property: 770 Elijahs Ln.,Mattituck SCTM#: 473889 Sec/Block/Lot: 108.-3-5.9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/15/2022 pursuant to which Building Permit No. 48074 dated 7/15/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Bathroom atleration to an existing one family dwelling as applied for The certificate is issued to Burns,William&Patricia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 40348 7-18-2022 PLUMBERS CERTIFICATION DATED 6-29-2022 Ch ' ian Bu th r d ignature �ooSUFF01 TOWN OF SOUTHOLD BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE o . Eft+� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48074 Date: 7/15/2022 Permission is hereby granted to: Burns, William 24975 Main Rd Cutchogue, NY 11935 To: Replace an existing bathroom window as applied for. Replaces BP# 40348. At premises located at: 770 Elijahs Ln., Mattituck SCTM # 473889 Sec/Block/Lot# 108.-3-5.9 Pursuant to application dated 7/15/2022 and approved by the Building Inspector. To expire on 1/14/2024. Fees: PERMIT RENEWAL $125.00 Total: $125.00 Building Inspector SSU �c TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE co o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 40348 Date: 12/15/2015 Permission is hereby granted to: Burns, William & Patricia PO BOX 987 Mattituck, NY 11952 To: replace an existing bathroom window as applied for. At premises located at: 770 Elijahs Ln, Mattituck SCTM # 473889 Sec/Block/Lot# 108.-3-5.9 Pursuant to application dated 12/13/2015 and approved by the Building Inspector. To expire on 6/15/2017. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 $250.00 1 Building lnsp 0 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 Date. /L��2a l� New Construction: -7 Old or Pre-existing Building: (check one) Location of Property: < . � S House No. Street Hamlet Owner or Owners of Property:G�i�s�c� ,Ul�rszs Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ so Ap Y scant Signature pF SOUryo! 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ sean.deviin(aD-town.southold.ny.us Southold,NY 11971-0959 Q�y�DUNT`I,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: William Burris Address: 770 Elijahs Ln city:Mattituck st: NY zip: 11952 Building Permit#: 40348 Section: 108 Block: 3 Lot: 5,9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor 1st Floor Pool New Renovation X 2nd Floor X Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures 1 Bath Exhaust Fan 1 Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO t4 Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 2 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Bathroom Renovation Second Floor l Inspector Signature: Date: July 18, 2022 S.Devlin-Cert Electrical Compliance Form Town Hall Annex ( Telephone(631)765-1802 54375 Main Road "r Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ' BUILDING DEPARTMENT J�� ��22 TOWN OF SOUTHOLD BUILDING DEPT. TOWN OF SOUTHOLD 1AR•T_IFICA.TLQN Dater Building Permit No.- Owner:- (Please o.Owner- (Please print) Plumber:.- (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. ,..rinbers Signature) Swom to before me this e� day of �, i OE, 20,�- Notary Public, 5AAALIk. �y TRACEY L. DWYER NOTARY PUBLIC,STATE6900 EW YORK QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2©� OF SO(/l�,°� # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 _ INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE ARKS: /'"�( tnctv&, dL DATECOIVI&16e� INSPECTOR - - --------- ,flat ---Uf SOUly�lo )AAS * * TOWN OF SOUTHOLD BUILDING DEPT. courm,��' 631-765-1802 INSPECTION ' [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: �� � s 01- �f 0&�� DATE INSPECTOR 1i 1 I 9 • " '' "� M 1 Ia f_ s� Uv 3� a • • Ii I ` o iNaUL,ATION. STATE ENE-ROY cbx)z • e i a ��e r R �� r,/I SSI ��• � , ♦ _.._ __ \ i I / �� • ' ' � 0 W � �� TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST $UILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Survey SoutholdTown.NorthFork.net PERMIT NO. S40K& Check Septic Form ' res N.Y.S.D.E.C. CC��:'i"'(_ ° _"l, , :��? CODES OF Trustees NEV i!�`. 5-1. .'; �� & TOWN CODES C.O.Application AS REQUIRED-AND CONDITION FloodPermit Examined ,20 Single&Separate ( Qp •Storm-Water Assessment Form iv ' on'taDt1 I ) . Approved 120 a " S��t IC}. ,r,''�TRlS ttS Mail to: Disapproved a/c --��` «- - N•Y,S.�)�� Phon6PPROVED AS NOTED Expiration �j ,20 DATE: B.P. 1 U( ! �, FEE: �Y:6 I Building I�spe r NOTVY Y BUILDING DEPARTIMIEN AT _ II� 65-1862 8 AM TO 4 PM FOR THE (� DEC 7 2015 APL CATION FOR BUILDING PERMfi'LLOWING INSPECTIONS: I. IF ATI N - TWO REQUIRED J a FOR�F CONCRETE D'G.t " i_ n n 4ihlr o C11 �,. �IJO U INSTRUCTIONS 3. INSULATION v 4. FINAL - CON`TRUCTION MUST a. This application MUST be completely filled in by typewriter or in ink and subAtLe�tNlil he BLlilcjP.gdr�§pector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. ALL CONSTRUCTION .SHALL MEET THE b. Plot plan showing location of lot and of buildings on premises, relationship tatjg;rl�ng,B�3 �Ufo}rbb�Stt � areas, and waterways. YORK STATE. NOT FiESPONSIBLE FOR c. The work covered by this application may not be commenced before issuance'�,Btljldit ft0ftRUCTION ERRORS. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, an regulations, and to admit authorized inspectors on premises and in building for necessary inspections. OCCUPAI�CYOR USEIS UNLAWFUL ignatu of applicant or name,if a corporation) WITHOUT CERTIFICATE OF OCCUPANCY ( ailing address of applic nt) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises_ ll s���-_! Gc-i✓i (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. �� f� G� Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on whic ,proposed work will be done: House Number` Street Hamlet County Tax Map No. 1000 Section �. Block Lot S r ] Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work W,9�= / ��rn �a✓�al � o�I (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units 41 `z Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO / Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Cjo s�-,I Address 7�) 4&i Phone Nook. PO z - F4s' Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below;must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this properfy? * YES,NO . * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF3u—�— being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the �j0� CA, ;(. (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the appfication filed therewith. Sworn to be,ore me thi E'R'eistration RY KAISER ic, state of New York day oma(/ 20 #01 KA4693464 in Suffolk County Expires Mar. 13z ld 1 tary Public Signature of Applicant Wt/`;O BUILDING DEPARTMENT- Electrical Inspector �y0 Gy TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 '* Southold, New York 11971-0959 oyfj0� �aO�Y� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-)southoldtownny.gov - seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMAT All Information Required) Date: Company Nam Electrician's me: ui License c. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: W L I I V�M g Ur-.,J S Address: -1-7v EL,J, W5 LA jC �AA' l—TUcv, NY Masa Cross Street: G-A&Z le LA Cp v r Phone No.: Bldg.Permit#: D3`f0 email: USGSy S� MA C. Tax Map District: 1000 Section: lC� `' Block: Lot: S• BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):, 20—PLACED Bflflnrua M O ui Le l t G F S Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION a N %X/P BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 ® ®'� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(absoutholdtownny.gov seand a(Dsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMAT All Information Required) Date: Company Nam Electrician's me: LSI License c. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: W hR to g vr1%J 5 Address: -1-76 ELt. W5 LAi c kA1i i7uc4 Iv'i H95a Cross Street: (.2 L„ C Q u r Phone No.: -,3t 575 3o 5 S' Bldg.Permit#: D3 TQ email: v5G5L45-e MAI CB Tax Map District: 1000 Section: tU `� Block: 3 Lot: S. BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 2a PLAcJ�o QO(,1 Iz i j C F1 Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# E]New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION qp� � V �o�e wr �l V 4 ��� ���-� PERMIT# Address: Switches l Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments.- .r ALEXANDER HOLDINGS LLC 55 ALBANY AVENUE AMITYVILLE, NY 11701 (631) 842-4057 wln.� December 7, 2015 To Whom It May Concern. We are requesting a permit to remove and reinstall a window for a bathroom remodel project at a home located at 770 Elijah's Lane, Mattituck, NY 11952. The current size of the window is 21x36 and we would be installing ONE larger window 24x36. The replacement window is a 3580 Horizontal Single Slider Window- MI • Vinyl frame • Insulated , glass tint-Clear —Low E, Argon Gas, Glass Strength —SSB • Energy Star rated- see attached If you have any questions please call Mona from my office at (631) 300-8938. We will be paying the permit fee at the time we apply for the application and would Appreciate the permit being mailed to our office at the above address when approved. Thank you. Sin7umkin, yours, Ira owner Alexander Holdings LLC Quote Date: 12/7/2015 ®® "RI N A Seeing You Through. Seeing You Through. 'ustomer Name: Project Name: Unassigned Project kddress: Quote Name: KELCO/72 PLUS Quote Number: 1168296 phone: Order Date: Quote Not Ordered 'ax: PO Number: 'ustomer Information: Comments: RO size for Flange is for standard 1 x buck with precast sill. Please contact your supplier for other Flange opening RO's. _. . ....... ..........;......_....................,.p......,_...._,................ _, .... ...... .......... TEM:&SIZES `� 'LQCA710N/=TAG:PRODUCT;DESCRIP7IQN ,.._;:. UIdIT.PRICE.I EXTENDED PRICE,'; -ine Item: 100-1 72 PLUS -- 72 ***PRODUCT*** quantity: 1 PLUS -- 72 Row 1 3580 2 Lite Single Slider-XO-1 Units-54W x 41 H PLUS -- 72 ***DIMENSIONS*** t0 Size: 54.5"X 41.5" 54W x 41 H Jnit Size: 54"X 41" PLUS -- 72 ***FRAME*** PLUS -- 72 Vinyl, Frame Type-Fin, Exterior Color-White PLUS -- **'GLASS***. Glazing Type-Insulated, Glass Tint-Clear, Low-E,Argon Gas, Glass Strength-SSB ***SCREEN**' Screen-Rollform Half,Screen Mesh Type-Charcoal Fiber,Screens Packed Separately-No ***WRAPPING*** Extension Jambs-None,J-Channel-None ***NFRC*** Series 3580::SingleSlider, U-Factor::0.29,SHGC::0.32,VT::0.58 Unit Price: $128.63 6580 2 Lite Single Slider-XO-CustomCustom Extended Price: $128.63 )uoted by: John Eusania Quote Number: 1168296 Pages: 1 of 2 Print Date: 12/7/2015 1:28:12 PM Century Building Materials . - La MI WINDOWS AND DOOMS 650 WEST MARKET S'T'REET • 6RATZ, PA • 17030-0370 SPECIFICATIONS SERIES 3580 NEW CONSTRUCTION HORIZONTAL SINGLE SLIDER WINDOW MAIN FRAME — Shall be made from rigid polyvinylchloride (PVC) multi-hollow extrusions which have a minimum wall thickness of.050". Main frame shall be welded together at the corners. Overall frame depth is 3-1/4". MOVEABLE SASH — Shall be made from rigid polyvinylchloride (PVC) extrusions which have a minimum wall thickness of.062". Sash to be of welded corner construction. Sash to have metal reinforcement in vertical members. FIXED MEETING RAIL — Shall be made from a rigid PVC extrusion with a .050" wall thickness. Meeting rail shall be secured to the main frame with three screw fasteners through injection molded end caps attached to the meeting rail with two screws. Bottom of main frame to have foam bulb to seal against the moveable sash. ROLLER TRACK SNAP-IN — Shall be made from rigid PVC with a wall thickness of .050". It shall "snap-fit" into the main frame sill. GLAZING — Fixed glass panel shall consist of 3/4" thick insulated glass. Glass to be held securely in place by the use of silicone based glazing at the exterior and a rigid PVC glazing bead at the interior. Moveable sash to be drop-in glazed using 3/4"thick insulated glass with rigid, extruded, vinyl, interior glazing bead. WEATHERSTRIPPING — Moveable sash shall have strips of center fin weatherstripping on each stile and on the top and bottom rails. Vent stile of moving sash to contain strip of foam filled bulb. HARDWARE -Two metal cam-type sweep locks to be located equidistant from each end of the vertical sash rail. Two sweep lock keepers to be fastened to the fixed meeting rail. All screws, clips, and other fasteners shall be made of non-corrosive materials compatible with aluminum/steel. SCREEN - Half screen shall be standard. Screen to be made from roll-formed aluminum, 5/16" x 3/4" with a .020"wall thickness. Screen cloth to be made from 18x16 fiberglass mesh and held securely by flexible, vinyl spline. Screens shall meet ANSI/SMA standard 1004-87. (NOTE: Insect screens are intended only to provide reasonable insect control. They are not intended to prevent people or objects from exiting the window or to provide security against forced entry.) INSTALLATION -To be done by others. Frame must be installed straight, plumb and level, without twisting, bowing or springing. Manufacturer's recommended installation procedures are to be used. Installer should make final adjustments to ensure proper sash operation and window performance. NOTE: MI WINDOWS AND DOORS' designs and manufacturing methods are continually being improved. Individual products may be subject to a variation in performance. Due to this and other factors, we reserve the right to change specifications without notice. It is the sole responsibility of the purchaser/installer to be sure that the intended use of this product complies with any and all applicable buildings codes (i.e. egress, safety glass near doorways,etc.). If you require further technical information regarding this product please contact your retailer/salesman. Rev.6/30/11 3580 Vinyl Horizontal Slider NH Windows and Doors Page I of 2 Change State:NY Dealer Login Search rr CertaInTeed Homeowners Professionals Resources Support About Us ..................................... New Search ................ 3580 Horizontal Slider 1 19,01-01 Update Search 3500 Series Application All The MI Windows and Doors 3500 Series is a new construction line of vinyl New Construction windows that offers superior value to builders and contractors. Replacement FEATURES Style All 0 Removable fixed glass panel is drop-in tape glazed in sash frame Awning 0 Brass Roller System Casement 0 Envirosealed Spacer System i.'.J Single-Hung 0 Integral J-channel LW Tilt Single.-Hung Double-Hung SPECIFICATIONS Horizontal Slider -1,01%............. .. El, Double-Slider - 2-7/8"frame depth E Picture Window 3/4"Insulated Glass Architectural Shape Bay Available in 1/4"size increments Bow Ej Garden ENERGY STAR ZONES 0 Basement Northern C. Patio Door r7* Specialty Shapes North-Central • South-Central Material • Southern R All Aluminum OPTIONS Composite Vinyl 4-9/16"or 6-9/16"Cellular or Wood Extension Jambs available ENERGY STAR Zone Mounting Fin All GLASS OPTIONS Northern COLOR OPTIONS North-Central Low E C' South-Central HP Low E White Lj Southem • Tempered Almond ..................... TechnicalDoes • Obscure HARDWARE COLOR OPTIONS ,, ,al Ratings I I Argon Gas Enhanced Therm - Color Match ............ GRID OPTIONS - 5/8"Flat CONFIGURATIONS Locate an MlWD Dealer • 7/8"Flat Y. MIWD 3580 Product Information Sheet Solar Energy Reflection Information r7—�I r- - Statement Ml Windows and Doors Limited Lifetime Customer 9 3580 Horizontal Slider Spec Sheet FE Assurance Warranty ELd Fj3580 Size Guide I 3580 Gross Section Drawing Its Subscribe to our gO% Become a Fan an Follow us on YouTube Channel Facebook Twitter hftp://www.miwd.com/individual-product-display/1043913-3580 12/7/2015 �You7hrcx�ix WindowVisible Light Complian:" • Below) Clear IG 0.48 2.08 0.64 0.67 N/A Low-E IG 0.34 2.94 0.32 0.57 N/A Low-E/Argon IG 0.30 3.33 0.31 0.57 HP-Low E 0.34 2.94 0.23 0.44 HP Low-E/Argon 0.30 3.33 0.22 0.44 MMMW- 3500 Single Hung Clear IG w/Grids 0.48' 2.08 0.57 0.59 N/A Low-E IG w/Grids 0.34 2.94 0.29 0.51 Low-E/Argon IG w/Grids 0.30 3.33 0.28 0.51 HP-Low E w/Grids 0.34 2.94 0.21 0.39 HP-Low E and Argon w/Grids 0.30 3.33 0.20 0.39 Clear IG 0.47 2.13 0.68 0.71 N/A Low-E IG 0.32 3.13 0.34 0.61 Low-E/Argon IG 0.28 3.57 0.33 0.61 HP-Low E 0.32 3.13 0.24 0.47 HP Low-E/Argon 0.28 3.57 0.24 0.47 OMMM 3500 Picture Window Clear IG w/Grids 0.47 2.13 0.61 0.64 N/A Low-E IG w/Grids 0.32 3.13 0.31 0.55 Low-E/Argon IG w/Grids 0.28 3.57 0.30 0.55 HP-Low E w/Grids 0.32 3.13 0.22 0.42 HP-Low E and Argon w/Grids 0.28 3.57 0.22 0.42 MMMM Clear IG 0.48 2.08 0.63 0.66 N/A Low-E IG 0.34 2.94 0.31 0.56 N/A Low-E/Argon IG 0.30 3.33 0.31 0.56 Thermal Performance Glass 0.29 3.45 0.31 0.56 HP Low-E 0.34 2.94 0.22 0.43 4300 Single Hung HP Low-E/Argon 0.31 3.23 0.22 0.43 Clear IG 0.48 2.08 0.56 0.59 N/A Low-E IG w/Grids 0.34 2.94 0.28 0.50 Low-E/Argon IG w/Grids 0.30 3.33 0.28 0.50 Thermal Perf.w/Grids 0.29 3.45 0.28 0.5 HP Low-E w/Grids 0.34 2.94 0.20 0.39 Eau HP Low-E/Argon w/grids 0.31 3.23 0.20 0.39 Iffun Clear IG 0.47 2.13 0.58 0.61 N/A Low-E IG 0.34 2.94 0.29 0.52 Low-E/Argon IG 0.31 3.23 0.29 0.52 HP Low-E 0.34 2.94 0.21 0.40 30/30 Glass 0.29 3.45 0.29 0.52 9555 Double Hung Clear IG w/Grids 0.47 2.13 0.52 0.54 N/A Low-E IG w/Grids 0.34 2.94 0.26 0.46 MIM Low-E/Argon IG w/Grids 0.31 3.23 0.26 0.46 MMM HP Low-E w/Grids 0.34 2.94 0.19 0.36 30/30 Glass w/Grids 0.29 3.45 0.26 0.46 Clear IG 0.38 2.63 0.49 0.52 N/A Low-E IG 0.27 3.70 0.25 0.44 Low-E/Argon IG 0.24 4.17 0.25 0.44 HP-Low E 0.27 3.70 0.18 0.34 9660 Awning Clear IG w/Grids 0.38 2.63 0.45 0.46 N/A Low-E IG w/Grids 0.27 3.70 0.23 0.40 MMMEF- Low-E/Argon IG w/Grids 0.24 4.17 0.23 0.40 HP-Low E w/Grids 0.27 3.70 0.17 0.31 MMEMM Clear IG 0.38 2.63 0.49 0.52 N/A Low-E IG 0.27 3.70 0.25 0.44 --j3rjM 291M Low-E/Argon IG 0.24 4.17 0.25 1 0.44 MMMM 8/6/2013 r C6 1 , Y 1 HP Low-e 0.27 3.70 0.18 0.34 MMMM 9770 Cassahf Clear IG w/Grids 0.38 2.63 0.45 0.46 N/A Low-E IG w/Grids 0.27 3.70 0.23 0.40 Low-E/Argon IG w/Grids 0.24 4.17 0.23 0.40 HP Low-E w/Grids 0.27 3.70 0.17 0.31 Clear IG 0.48 2.08 0.65 0.68 N/A Low-E IG 0.33 3.03 0.32 0.58 N/A Low-E/Argon IG 0.30 3.33 0.32 0.58 EM M 3580 Slider HP Low-E 0.33 3.03 0.23 0.45 3580�Srlder Clear IG w/Grids 0.48 2.08 0.58 0.61 N/A Low-E IG w/Grids 0.33 3.03 0.29 0.52 Low-E/Argon IG w/Grids 0.30 3.33 0.29 0.52 HP Low-E w/Grids 0.33 3.03 0.21 0.40 Clear IG 0.47 2.13 0.57 0.60 N/A Low-E IG 0.34 2.94 0.29 0.51 Es Low-E/Argon IG 0.31 3.23 0.28 0.51 9880 Slider HP Low-E 0.34 2.94 0.21 0.39 Mn Clear IG w/Grids 0.47 2.13 0.51 0.53 N/A Low-E IG w/Grids 0.34 2.94 0.26 0.45 Low-E/Argon IG w/Grids 0.31 3.23 0.26 0.45 HP Low-E w/Grids 0.34 2.94 0.19 0.35 Clear IG 0.47 2.13 0.64 0.68 N/A Low-E IG 0.32 3.13 0.32 0.59 Low-E/Argon IG 0.28 3.57 0.32 0.59 910 Slider HP Low-E 0.32 3.13 0.23 0.45 MMU Clear IG w/Grids 0.47 2.13 0.57 0.60 N/A Low-E IG w/Grids 0.32 3.13 0.29 1 0.51 Low-E/Argon IG w/Grids 0.28 3.57 0.29 0.51 HP Low-E w/Grids 0.32 3.13 0.21 0.40 *All ratings for grids reflect flat grid options *Above values can vary depending on use of flat grids or sculptured grids and optional glass thicknesses upgrades such as 3/16",1/4"laminated,1/8"tempered,3/16"decorative glass etc...Please visit our website at www.miwd.com for more Definitions HP Low E-High Performance Low-emissivity glass with a transparent coating which acts as a thermal mirror-used to Low E-Low-emissivity glass with a transparent coating which acts as a thermal mirror-used to increase a window's Argon-An inert,colorless,and harmless gas used instead of air in sealed spaces between panes of glass in insulating glass Grids-Decorative inserts for windows or door glazing that adds a traditional touch-available in flat and sculptured. U-Value-U-Value measures the rate of heat transfer and tells you how well the window insulates.The lower the U-Factor, SHGC(Solar Heat Gain Coefficient)-measures the fraction of solar energy admitted and tells you how well the product blocks VLT(Visible Light Transmittance)-measures the amount of light the window lets through.The higher the VT,the more light R-Value-R-Value measures the thermal resistance of a window. Energy Star Compliance �• ® Northern North-Central South-Central f Southern Wt, ,w 8/6/2013