HomeMy WebLinkAbout48298-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 48298 Date: 9/16/2022
Permission is hereby granted to:
TWILLIAMS/BTSIEN LLC
222 Central Park S
New York, NY 10019
To: construct an accessory structure enclosing an in-ground swimming pool as applied for.
At premises located at:
Greenwood Rd., Fishers Island
SCTM # 473889
Sec/Block/Lot# 12.-1-19
Pursuant to application dated 5/18/2022 and approved by the Building Inspector.
To expire on 3/17/2024.
Fees:
ACCESSORY $184.00
SWIMMING POOLS -ABOVE-GROUND WITH REQUIRED FENCING $250.00
CERTIFICATE OF OCCUPANCY $50.00
Total: $484.00
BuYJ= �cSpector
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959
t Telephone (631) 765-1802 Fax (631) 765-9502 lett) :// Wv,Vv. oLrtlloldtow iiii ,, o°
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
Il PII LII.�II .I �
PERMIT NO,
Building Inspector;. I$
MAY 1 8 2022 `
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,anl:tUrh.q.."lq�lING DEPT
Owner's Authorization form(Page 2)shall be completed. 10OF`O iTHOLD
Date:JANUARY 24, 2022
OWNER(S)OF PROPERTY:
Name:TWILLIAMS/BTSIEN LLC =SCTM # 1000-12.-1-19 /473889
Project Address:GREENWOOD ROAD, FISHERS ISLAND
Phone#:212.582.2385 Email:AKRUHLY@a TWBTA.COM
Mailing Address:222 CENTRAL PARK SOUTH / NEW YORK, NY 10019
CONTACT PERSON:
Name:ALEX KRUHLY
Mailing Address:222 CENTRAL PARK SOUTH / NEW YORK, NY 10019
Phone#:212.582.2385 Email:AKRUHLYQa TWBTA.COM
DESIGN PROFESSIONAL INFORMATION:
Name:ALEX KRUHLY
Mailing Address:222 CENTRAL PARK SOUTH / NEW YORK, NY 10019
Phone#:212.582.2385 Email:AKRUHLYC TWBTA.COM
CONTRACTOR INFORMATION:
Name:MARK RICHARDS - BD REMODELING & RESTORATION
Mailing Address: 1420 THE GLOAMING #447 / FISHERS ISLAND, NY 06390
Phone#:860.912.9537 Email:MARK@BDRRUSA.COM
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
DOther POOL $100,000
Will the lot be re-graded? iRYes !rJNo Will excess fill be removed from premises? iiYes ®No
1
PROPERTY INFORMATION
Existing use of property: RESIDENTIAL Intended use of property: RESIDENTIAL
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
B this property? ❑Yes RNo IF YES, PROVIDE A COPY.
W Check Box After Beading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name):ALEXANDER KRUHLY BAuthorized Agent ❑owner
Signature of Applicant: Date: JANUARY 24, 2022
STATE OF NEW YORK)
SS:
COUNTY OF NEW YORK )
ALEXANDER KRUHLY being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the AGENT
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application; that all statements contained in this application are true to the best of his/her knowledge of-f; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of 20 Z
ENotary
,:
AVA FALIN
c-State of New York01FA6352784
PROPERTY R T II 1Id in Kings County
n Expires Jan 3,2025
(Where the applicant is not the owner)
I� TOD WILLIAMS residing at GREENWOOD ROAD, FISHERS ISLAND
do hereby authorize ALEXANDER KRUHLY to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
�J JANUARY 24, 2022
Owner's Signature Date
TOD WILLIAMS
Print Owner's Name
2
OWNER TWILLIAMS-BTSIEN LLC ZONING DISTRICT B - GENERAL BUSINESS
222 CENTRAL PARK SOUTH
'NEW YORK, NY 10019 LOT SIZE 17,587 SF
ADDRESS .. WILLIAMS TSIEN RESIDENCE ALLOWABLE LOT COVERAGE 30% f
GREENWOOD ROAD /
FISHERS ISLAND, NY 06390 EXISTING LOT COVERAGE 4,565 SF BUILDING = 26% L
PARCEL SCTM 473889 PROPOSED LOT COVERAGE 277 SF POOL + 4,565 SF BUILDING
1000-12-1-19 4,842 TOTAL COVERAGE = 27.5%
ACCESSORY STRUCTURE
,S S'e .5�1 _____-��- SETBACK
_ _ _ - 40 GALLON DRYWELL FOR
D <p _ _� ___-- '- STORMWATER RUNOFF.
Q` ��i �� � � _ _ 6 LOCATION TO BE
S E P 1 2 2022 (.� �o — _— — \
_ 18�. DETERMINED IN THE FIELD
NEW STONE DECK
BUILDING DEPT. � - - - - � \\ \ AND BENCH
TOWN OF SOUTHOLD NEW PRECAST PLUNGE POOL
13'-11' 14'-9" PER SOAKE SPECS
�EXISTING TERRACE TO BE S
ENCLOSURE WITH PER t/
_ REGRADED TO CREATE I �� AND CANOPY ABOVE
--- - NATURAL LANDSCAPE BERM
- -
TCHING
I _
CUSTOM METAL DOOR
NEW STONE BRIDGE
o N REAR YARD \ � FROM BERM TO POOL
M J LO
POOL EQUIPMENT TO BE
LOCATED IN BASEMENT
IZ L------------------- — \
_... ——————— — — AND INSTALLED PER
\ MANUFACTURER'S SPECS
. I
\,n
FISHERS ISLANDI00
\'
CORPORATION I ' EXISTING �\ TOWN OF SOUTHOLD
BUILDING o 1000-12-1-4.4
1000-12-1-5.1 i o,
I q p p M p p p p (A
- - - - - - - - - - _ 223.04' - - - - - - - - - - - -
O S 49'44`04° W
RIGHT OF WAY
(HOUND LANE)
TOD WILLIAMS BILLIE TSIEN Architects PartnersD'�� FISHERS ISLAND WAREHOUSE RENOVATION
WILL Y,Jdp,
MrLDate 09.06.2022
..A .r Issue for Pool Permit SITE PLAN
222 Central Park South 212.582.2385 Hound Lane Scale 1/16"=V-0"
■
New York,NY 10019 akruhly@twbta.com 9�o01155
N�J,ioe Fishers Island,NY 06390 AO- 0
I
E-_
- ` -
1-T-7-1
STAINLESS STEEL CHANNEL,
CONTINUOUS CORNERS
,
...:. ' TEMPERED GLASS PANELS_ 3/4
T ........-,_-
-- --�- -1_w - -i ..
L IT- j
'-
= -•- i- - �- - j
--- �----�---;—j - =---- -- EXISTING TERRACE TO BE REGRADED
-1- �- - 1-T- j _.
-----L,--�-T---Tr--- . TO CREATE NATURAL LANDSCAPE BERM
� -
- -
- - - _ - -
--- - i
+ i i i ! }. �� `�_�•• \` / / �-1���,� � .. � / Jig �, I
IV
I T i _ I -- /i�,\i'� - �r �• /, `�/ ,, . � \�.�\` ,i i'-'tel/:
v
___ '� r•
--.L _j
F.
-T_ 1
STAINLESS STEEL GLASS ANCHOR
CAST—IN—PLACE CONCRETE RETAINING WALL
I
I
I
I
I
TOD WILLIAMS BILLIE TSIEN Architects I Partners W?AFISHERS ISLAND WAREHOUSE RENOVATION
Date 09.06.2022 EAST ELEVATION
Issue for Pool Permit TYPICAL
b Scale 3116"=1'-0" )
222 Central Park South 212.582.2385 �; :�� Hound Lane
A200
New York,NY 10019 akruhly@twbta.com q� 7755+ �o� Fishers Island,NY 06390
OF NvdJ
,
^
/
STAINLESS SEEL PERGOLA,
RETRACTABLE SHADE CANOPY BELOW
f OP
3J4 TEMPERED GLASS PANELS
L I—
STAINLESS STEEL TOWEL BAR BEYOND V
JIL
STAIRS AT EXISTING BUILDING
STAINLESS STEEL GLASS ANCHOR
EXISTING CONCRETE RETAINING WALL BEYOND
FO 0
PRECAST SOAKE PWNGE POOL,
CUSTOM TILE CLADDING STONE SLAB BRIDGE AND EXISTING TERRACE TO BE REGRADED
CONCRETE FOUNDATION BEYOND TO CREATE NATURAL LANDSCAPE BERM
2' RIGID INSULATION PER SOAKE SPECS
CAST—IN—PLACE CONCRETE RETAINING WALL CUSTOM METAL DOOR BEYOND. SELF—LATCHING
AND SELF—CLOSING PER CODE REQUIREMENTS
4" SCHEDULE 40 PERF ------- 30 STONE BENCH TO MATCH PAVERS
PIPE PER SOAKE SPECS
LT
`
TOD WILLIAMS B|LL|E TS|EN Architects Partners FISHERS ISLAND WAREHOUSE RENOVATION
Date 09.082022
CROSS SECTION
Issue for Pou Pann�
222 Central Park South 212.582.2385 Hound Lona — Scale 30^=11-01, FACING SOUTH
New York, akmh|y�bwb��xn � ~ | Fishers NY
A201
| | | | |
a
CD
N O
0
O CD v
� C `i
R � G
y
< m r
o D
Oi c
CO C CY)
W -
r
r
m
m
z
D
m
m n
N 1 3/8"
l< ;
Cel N m N
N = 3/16" STAINLESS
o W CD STEEL STRUT
s80,
3/16" STAINLESS
STEEL STRUT HANGER
` 3/16" STAINLESS
A' ("STEEL U–CHANNEL
s
°� SILICONE SEALANT
a RETRACTABLE SHADE
CANOPY
3/4" TEMPERED GLASS
SECTION DETAIL ENCLOSURE HEAD
T 0 T 2
o_ m
1 3/8"
CL CD cn 3'-0"
3/4"
z cn
CD m a
w z
o77v
a
_ / / 3" STONE SLAB / 3" STONE PAVER
r / 1/2" CONTINUOUS 3/4" SETTING BED
m STAINLESS STEEL T o
3/4" CRUSHED STONE
m STAINLESS STEEL °
z FASTENERS 3/4" TEMPERED GLASS
O o 0
n d - I a I I d STAINLESS STEEL PINS, _ X3/8" ANCHOR BOLT;
4 1/2" MIN EMBED
o I I I I CUSTOM STAINLESS STEEL _ °
Z 5 T–CONNECTOR; ANCHOR _:– 3/16" STAINLESS STEEL
BOLT EMBEDS — I L–ANGLE
Ci 10" CAST–IN–PLACE _ a SILICONE SEALANT
CONCRETE PIER –III a 6" CAST–IN–PLACE
I= CONCRETE RETAINING WALL
—IIII
° .
a d G
d —III d a
— a°
_I —_ _ I . III— I—
I—
SECTION DETAIL BRIDGE—PIER CONNECTION SECTION DETAIL ENCLOSURE BASE
cn v
B m
10" 6"
O
i
N O
O
N III—III— d a d —III—IIII —I I I III
10" CAST–IN–PLACE =III - I I=I
d d = 1=1 I - CONCRETE PIER =—=I = _
—I I —I — d a: —III— I
III—III- I I—I 1I
6" CAST–IN–PLACE
=III—III a a I —III- — CONCRETE RETAINING WALL
IIIc' d ° da III a _ 6"x12" CONTINUOUS
a d a . — CONCRETE FOOTING
_ a d d a - 20 BELL FOOTING = d = (2) #4 REBAR
OMPACTED SUBGRADE OMPACTED SUBGRADE
1t-8" 1$-o"
SECTION DETAIL BRIDGE PIER FOOTING SECTION DETAIL• RETAINING WALL FOOTING
® " 1 1/2" = 1'–O" 1 1/2" = 1'-0"
e
J
Exhibit C: Product Instructions
Please provide a copy of this instruction guide to all subcontractors working on the project.
Excavation, Site Prep, and Exterior Finish Work
Follow instructions(Diagram A on next page)for Do not use a vibratory plate compactor near the pool
preparing site,but modify as needed for specific wall.Hand tamp only.Vibratory compactors increase
location,taking into account the desired finished the risk of hitting/cracking pool wall or sending flying
elevation,geo-technical data and water table.We . debris that can chip the tiles.
recommend 12"-18"crushed stone beneath pool with
drainage to natural light as specified in Diagram A.We Excavate approximately two feet,(but not more than
recommend 3/d'crushed stone as backfill except around two feet) beyond outside dimensions of the pool on all
PVC,where 6"sand above and below is preferred. four sides.This is important if a boom truck is delivering
Excavator should laser-level the prepared area. so that crane can reach center of pool during delivery.
If overdig is too wide,boom truck may not be able to
place pool in desired location as the crane's reach is
limited to 15'-1 Tclepending on pool weight.
soakepools,corn 603.749.o66,5
Diagram A: Raised Installation
NOTE:DO NOT DRILL INTO POOL
STONE COPING STRUCTURE FOR ANY REASON
OR ATTACH WALL VENEER
ANCHORS TO POOL STRUCTURE.
STONE VENEER EXAMPLE
PATIO/DECK CAULK AT PATIO/COPING EXAMPLE E
MATERIAL INTERSECTION
PATIO/DECK _
SETTING BED
MIN.1 4"PER FOOT PATIO SLOPE
FINISH GRADE _ AWAY FROM POOL STRUCTURE
(TYPICAL AT ALL SIDES)
In
(.•,', - .�f u Y O_!"' -POOL INTERIOR
COMPACTED - Is 'Q• �1' COMPACTE
C D'
i-. PATIO SUBSTRATE o ! a PATIO
SU_BSTRATE .
314'CRUSHED ._ �_7 3J4"CRUSHED
FILTER FABRIC STONE BACKFILL o_ O - STONE BACKFILL FILTE—WEA-ac--I
•t' �
E--TRENCH TO EQU.AREA -.� _ ' ,e• ,.
AT SETTING BED ELEVATION .r'rT.O.:5E7TINGBED _
FILTER FABRIC /''4'SCHEDULE 40 PERFORATED PIPE
,..,/ DRAINING IC L ENGINEER
S �^ "' - `•'
----�- i LJ GEOTECHNICAL ENGINEER SPEC'S v
LEVEIEb�&GOMPACTEb- ri
h 3/4"'CRUSHED STONE• - ^. -,-- •- - "-- -- _
,�SETTING.BED - _ .__' -.z~ -._ _ : _• ,
MIN." MIN-77,-7,, :• '-��
GRAPHIC SCALE: NOTE:Methods described for backfill and compaction are
0 6" V 2' 4- B, not guaranteed to be Ideal for all sites.To be certain
ofwhat method you should use,consult a licensed
geotechnical engineer&structural engineer In your state
Backfill plumbing trench with a bed of sand.In Masonry
freezing climates in addition to the sand,we
recommend the pipes be placed on rigid foam board Exterior build-out
and spray foamed on top once pressure test has'been
completed.This keeps the heat loss to a minimum. Pool walls are 4"thick.The Skimmer protrudes
approximately 11"beyond pool wall on one end of
Use 2"rigid foam around all sides of pool wall before pool.See Diagram C and Exhibit A-1 for dimensions.If
finish work is applied.When rigid foam is being used, you need to build out the pool wall to accommodate
excavator will apply the foam to exterior of the pool coping,you may use concrete block,poured concrete
with construction adhesive before backfilling.This or other method you choose.You will need to allow
foam increases heat loss protection:(Foam provided-by- access to-the top-of skimmer(for cleanout of basket).
Soake unless otherwise specified).Final grade will be Below are some examples of removable coping over
determined.by excavator and mason (or project GC). skimmer and photos of skimmer protruding from
pool.We highly recommend a Hide Skimmer Lid if
Excavator is required to be,present when pool is removable coping piece is being used.
delivered to help guide pool into position,verify pool
is in specified location,and be on hand to help should - I, - - -
there be any final leveling adjustments.
'�•,� '- q,
- 't
Note: ---
If an autocover is beinginstalled,be sure to account '
Tr
for the height of the autocover tracks.Tracks are either !
1 1/16"or 1 5/8"depending on design...please check - - - .
with Soake for your track dimensions.
2
Oo not drill or shoot anything into outside of pool wall While applying coping with mortar or other similar
including wall veneer anchors. products,cover the pool tile with a drop cloth so that
mortar does not fall onto and adhere to tile.
For best insulation,especially in freeze climates,use 2" ;
rigid foam around all sides of pool wall before finish Examples of typical exterior finishes:
work is applied.
• Coping: Depending on coping width,wall may
Protecting pool during need to be built out to accommodate it.Methods
construction of widening pool wall include
Skimmer Dimensions pouring a concrete"apron"around
While working on exterior of pool, 15 ins` - —1-3/8" to 3.1/8° pool,building with blocks,and
cover pool opening with plywood
Adj.Collar building free-standing ftdin stone wall.
-4-+�/16'ti'' • —
or similar material to avoid dropping _ -5-3/+67-- + When possible,include rigid foam in
tools into pool and to keep dirt and 7.3/8'I the build-out,sandwiched between
debris out during construction.Tile I5-5/32" 00l and concrete apron.
p p
may crack if a tool is dropped into - oam;;° 19.7/8.
1 1-11 '° • Wood decks butted to pool edge
opening.If pool is left unfinished
during winter months.or freezing can be built without building out
temps,.pool should be covered and - ;2-3/8i pool wall in most cases.
tarped so that no water gets in. '
I.--Tara°- ---4°--I
Before After
�..
.�''.'�'.i=�a...._r,�.� - n,.,•.• . r.�.�.f{ ,vim.
3
Electrical specified. Panel is prewired for 100'cord and would
need to be modified if a longer cord is used.
All electrical work must be performed by a licensed Note: You must use both the primer and pool glue for
electrician.We cannot warranty electrical work.Follow all connections.
manufacturer's specifications in 1/0 manuals for
electrical voltage and amp requirements.Below is a Follow instructions in light manual for location of
summary and is not meant to replace manuals.Follow Junction box in relation to water level.
all local and national electrical codes. Install light
Summary You will need to thread the light unit into fitting
Flo Pro VS Pum 230v(15 A) provided.Light must be installed and run through
Pump conduit before pool can be filled with water.Please be
JXI 260 BTU Heater......120/240 v(5A) sure light is securely threaded into fitting.
Automation ................... 120 v(3A)
*Sanitizes(if salt)..........included in power center Bonding
........................................ 120/240v (3A power center) Bond pool with 8G bare copper wire at all bonding
Light..................................115v(less than 1 A) wire leads,and at the zinc water bond anode. Run the
wire back to pool equipment and bond as required
• Light is low voltage underwater light and uses by local and national electrical codes.Follow bonding
light transformer. visual aid (attached as Diagram B). Please note that
• Light must receive exactly 12 volts from transformer MA now requires a copper mesh around pool in
* If mineral/chlorine sanitizer is used, no power is addition to the bare copper wire loop.Our pools
required for this component. have an ETL listing for bonding wire.The ETL sticker is
Bold indicates that this is the factory setting. found on the exterior of the pool.
In most cases we will be supplying an automation Air temperature sensor installation
panel that has its own subpanel,and all breakers A sensor marked"air"coming out of the control panel
will be pre-installed. Electrician will simply need to � measures the air temperature.It can be mounted near
connect the power supply to the subpanel. the panel,outside of the panel box and protected
In cases where we are not pre-installing breakers, from the weather.
please follow the guidelines below:
Communication Connections
Pool Pump:Use Siemens QF220P 20 amp breaker or
Pentair PA220 GF 20 amp breaker. Pump:There is a four-wire cable labeled"pump"that
should be run and terminated at the four-pin
Breakers for other equipment compatible with power connecter inside the rear of the pump. 1-2-3-4,Red,
center sub-panel:Cutler-Hammer,Murray,Siemens, Black,Yellow,Green.
Square D,and Thomas&Betts.
Heater:There is two-wire cabled labeled"heater"that
Note: Equipment has been pre-wired to automation. should be run and terminated at the blue three-pin
Do not move or re-wire relays or communication block inside the heater(J6).Connect to pool and
cables. common (not to spa).Wire colors are interchangable.
Niche-less light:
Connect a 1"conduit to the 2"-1"reducer provided.
Run the 1"conduit from reducer to light transformer
at equipment pad.
We provide a light with 100'cord unless otherwise
4
r
Diagram B: Bonding Visual Aid
Important note for Massachusetts electricians:The 680.26(B)(2)(b)"copper ring"perimeter deck
bond for ingrOUnd pools is not permitted under 2020 Massachusetts Code Amendment. Perimeter
bonding must be done per 680.26(B)(2)(a)or 680.26(B)(2)(c)reinforcing steel or copper grid.
LISTED'PRESSURE CONNECTORS
OR OTHER MEANS OF CONNECTION ALL METAL WITHI7E..E AS LI57ED PER N.E.C. S'OF THE WATER'
TO BE BONDED
8 AWG BARE SOLID COPPER BONDING '
CONDUCTOR CONTINUOUS AROUND POOL
PERIMETER 4-6"BELOW DECKING SUBGRADE LADDER ANCHOR BONDING LUGS
18"TO 24"FROM WATER'S EDGE PER N.E.C. - �^ SEE LADDER MANUFACTURER'S SPECIFICATONS
FOR BONDING LUG LOCATION
EXTERIOR BONDING LUG AT
ALL BOTTOM CORNERS OF POOL TANK. z:a
NOTE:APPROVED LUG FOR DIRECT BURIAL f g
MIN.18" c
MAX 24" -.SKIMMER LADDER-7j-
To
ADDER
CONTINUOUS BOND � e
TO POOL EQUIPMENT - EXTERIOR BONDING LUG.,'
'LOW VOLTAGE -AT ALL BOTTOM CORNERS-
OFPOOLTANK.
Alternative when needed: - NICHE-LESS LIGHT, METAL
"BOND SAFE 680"WATER - NOTE:APPROVED WG
BOND PLATE INSTALLED AT - FOR:DIRECT BURIAL, MIN.18"_ FENCING•_\
SKIMMER SEE INSTALLATION - POOL MAX 24"
MANUAL FOR DETAILS
PHONE:(781)760-6320 -
_ EXTERf6R BONDING,LUG'
' •AT ALL BOTTOM CORNERS'
PREFERRED: 5= oFPooerANK . " 5—
NOTE:APPROVED LUG
WATER BOND IS AT FOR DIRECT BURIAL
ZINC ANODE...IN
THIS CASE NO
SKIMMER PLATE
WILL BE INSTALLED
EXTERIOR BONDING LUG AT "��`+ CONTINUOUS WELDED WIRE MEjj�
F'4 IL
ALL BOTTOM CORNERS OF POOL TANK. z CAST IN CONCRETE SHELL
NOTE:APPROVED LUG FOR DIRECT BURIAL
NOTE:Methods described for backfill and compaction are not guaranteed to be ideal for all sites. To be certain
of what meethod you should use,consult a licensed geotechnical engineer&structural engineer In your state
5
Plumbing and Gas Fitting creating an airlock.Do not run pipes up in elevation
from pool and then back down again.
The pool fittings are pre-installed to enable a quick We recommend rigid 2"schedule 40 PVC for all
and simple installation process.We cannot warranty underground plumbing.In freeze climates,or to
plumbing connections.For all plumbing connections, minimize heat loss, insulate pipes according to best
use the both primer AND PVC pool glue.We will practice for area.We provide a closed-cell foam spray
provide the glue and primer or recommend one for insulation in most cases (see excavation instructions).
your project.
The plumbing components that require installation are: Equipment connections
Follow manufacturer's instructions for all plumbing
Skimmer connections to equipment.Flow diagram attached.
Manuals are provided and will arrive with equipment.
The skimmer has a 2"PVC slip connection.We We can supply manuals prior to equipment delivery if
recommend plugging the port closest to the pool requested.
wall,and plumbing the outer port.Connect skimmer
line to pump at equipment pad . Water temperature sensor installation:A sensor
marked"water"coming out of the control panel is
Returns installed in the water flow path between the pump
The returns have 2"PVC slip connections.Run one line and the filter.To install this,drill a 3/8"hole on one
from salt chlorine generator to pool and split the line side of the PVC piping between the filter and pump
to the 2 return fittings at pool. (Alternatively,line can and insert the sensor into the hole,then use provided
be split at equipment pad and two return lines can be piping clamp and tighten.The sensor includes a
run to the pool.) gasket to seal against the outer wall of the piping.
Underground plumbing Gas connections
Follow plumbing diagram (Diagram D).We recommend All propane or natural gas connections must be done
running a single 2"schedule 40 PVC pipe for the returns by a licensed gas fitter.This includes connections
with a T-connection near to the pool.Take care to avoid from fuel supply to heater and heater venting.We will
supply a pressure relief valve for heater,and gas fitter
must install according to local codes.Important:Verify
Pool Equipment Layout Pump with your local natural gas company that your current
Heater meter will support the additional 260,000 BTU load that
Zinc anode- the heater will need.Gas fitter should verify that gas
�\ , 1 supply has capacity to meet PSI requirements well in
® y advance of your pool delivery and make any changes as
Filter iW
required.Gas fitter should also verify that your desired
Check valve heater location meets local codes.
Check valve
Salt cell Optional:can install
r
when equipment is `
above water line
Pool return
2-way valve
From skimmer v x=_.<:_.
6