Loading...
HomeMy WebLinkAbout45903-Z �OSUEFOZ L cots Town of Southold 7/14/2022 � j P.O.Box 1179 o _ 53095 Main Rd y� ao�A Southold,New York 11971 4 CERTIFICATE OF OCCUPANCY No: 43248 Date: 7/14/2022 THIS CERTIFIES that the building FARM STAND Location of Property: 36450 CR 48,Peconic i SCTM#: 473889 See/Block/Lot: 69.-4-8.7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/24/2021 pursuant to which Building Permit No. 45903 dated 3/10/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: new farm stand as applied for. The certificate is issued to Wesnofske Jr,Eugene i of the aforesaid building. I SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45903 ;47/2022 PLUMBERS CERTIFICATION DATED Au o ize S gnature i I TOWN OF SOUTHOLD Gy BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE o • SOUTHOLD, NY � BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES j WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) I Permit#: 45903 Date: 3/10/2021 I Permission is hereby granted to: Wesnofske Jr, Eugene 36450 CR 48 Peconic, NY 11958 j i To: demolish existing farm stand and construct new farm stand as applied for. i �I II I �I At premises located at: 36450 CR 48, Peconic SCTM #473889 Sec/Block/Lot# 69.-4-8.7 Pursuant to application dated 2/24/2021 and approved by the Building Inspector. To expire on 9/9/2022. I Fees: FARM BUILDING-NEW $150.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00' i i i I Bui g Inspector o��oF so�ryQl � o Town Hall Annex Telephone(631)765-1802, 54375 Main Road P.O.Box 1179 G Q �o sean.deviin(.a-)town.southold.ny.us Southold,NY 11971-0959 Q�yCOU %�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Wesnofske EL Jr Irry Trt Address: 36450 CR 48 city:Peconic st: NY zip: 11958 Building Permit#: 45903 Section: 69 Block: 4 Lot: 8.7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Owner License No: SITE DETAILS Office Use Only Residential Indoor X Basement Service Commerical X Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 17 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 3 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 100A A/C Blower Range Recpt Ceiling Fan 2 Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 3 4'LED 1 Q Exit Fixtures Pump Other Equipment: 100A Sub Pane 24 Circuit/6 Used Notes: Farm Stand i Inspector Signature: Date: July 7, 2022 S.Devlin-Cert Electrical Compliance Form O� *OF SOUTH° -- - - - - - - - - -- '.Y # �# TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 I N:SPECTION [ ""FOUNDATION 1-S [ ] ROUGH PLBG. [ ] FOUNDATION 2N [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL J : ] 'FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: .- DATE 03 / INSPECTOR �a0f 50UlyO - .TOWN OF SOUTHOLD, BUILDING DEPT. 765-1802 . . . INSPECTION [ ] FOUNDATION 1ST [YY] RO GH PL13G.OUNDATION 2ND [ LATION/CAULKING FRAMING/STRAPPING [ L [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ( ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/ ..REMARKS: 64/_ DATE INSPECTOR Lf 5D / sf SOUIyo� * # TOWN OF SOUTHOLD BUILDING DEPT. co 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ `] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION" [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATI N [ ] PRE C/O REMARKS: DATE 050Z2- INSPECTOR 0 0�/ - --- ------ .`oqjF sollt, H " 04- - --- —- - -! - — - ---- # # TOWN OF SOUTHOLD BUILDING DEPT. °ycourmN�' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] .ROUGH PLBG. ( ] FOUNDATION 2ND = . [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: �/'/I� e e7 oi r c �r 010 14-- f 0i L4 jr- 11 _ c4-,, a / o vVer DATE ! ZZ INSPECTOR — o�A&I SOUjyO 1 5 G f # TOWN OF SOUTHOLD BUILDING .DEPT. 631-765-1802 INSPECTION ' [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) �LAELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: OK DATE 1i INSPECTOR ��`' j i r '� t iy._... + .. �,.ff *• x Ili; I _ 7 i� �x�' t.�' � ..- - ..a:...,_ _ .."o'Via•....+ 'ir='t.....r"'"ay_ 1►� w ••v.�r• .!'JF1/.gL4K.J4iY.Y'G65. 4,a,`-~. � •_.i �r ... -•.... .... vtJ9i'fi'�M•'J+StI� Y• � !a J� :jy/11 r`� .%/ > '� ._-. .T •. �� ✓+'{'F ,.. xY"'Yr�,�'" x ♦.�'`�'f'az y: s.�.iti%i i'�� .'; k d'�'�ri�.�°✓�'(v. .ice'r,�� .+;:2' �i. �"'. 1!.%,,ti J � h.r,/"G-ed Y„jrt J/q i �•� � �ry:;'•�'t �}ar. ...�`y! ar i` a ; + Y(.� y', ori y� .r : // n "` b.t,. x+y N �•'t ,f t p 1 �,*. Jy .. � r �•�-?+ f (-r:! r.t r Z_� �, �.r,�fi�+l'' �+�•J M'k \1� •`.., + iv.. i7 j. eS �` i IP IN • \k. ._ ♦ ,�« � ,_ t a. �'" =Z = ,� ,�� �� of`�#"� p,Y;aS b . # FF ��., Jf � �+f�,L� 3. �•s;<�t��t Y't � _!-�. F,�� 'y&'. ` !+ " r +• r� �.' 1 �' �� 7-0�;\C*\�.w.�t � "mak, ,F ro' � t-. I. r ,3 � ' `eu;•;,,v C �,,ea d ,; 5 -y ..vim .. ..� �-/+'- Y'I.Na ..•�'••"{�2�C^�+ +�, a-i11e} ,. a �� &+�, ! _ PJM t �•� � = y t s z w' :. Sim • 3Y^y Z t yf s.1. a`� 9 " , f >r ,. �e' � � j° _ .-•--•' .'a � � ''.•i�'— .`ti�.+,� *' ice,-- ..- it W2 .�Y. �: a rte._••--�`"-- �'x '+" :, "°. ..�.,y�' ,� - ♦' n i ter. . •'rr�C' 'rn`' ,a �.� yam,� �. �' w,- iI �.;_.. Ts i t `Y. x e`i �` `"-'�' • G- '` .`e. to .'� �.'�- .� �. ^��• "\ � ~ Y• Tom' ��.:. ,.�- ! ;�' r.T.E� +. k.`1^ - - Al M T P^ ,,., x +_ '_—,-_-�-• - - Ate'-�.. � .�N.i: a A 41 �Y' 'i,/�+ �,a �•' e Y it(..`i;•3 �. ; .. -r'�'„'fw-:1_..jd�� : j.���' tit.i�♦' r�y' @x a d d4 � 7 4 31 Q 3 y } y' wr n t. �I w a. + ° - r r a ,x R, «�- - I�« � "+R" "�� ;1+R�t!lir ♦4 h i'Y # }, y , f'I S FIELD INSPECTION RFPORi DATE COMMENTS b *KION(1ST) G H V] ---------------------------------- ci 'FOUNDATION (2ND) _ z W O ROUGH FRAMING& C trJ PLUMBING t INSULATION PER N.Y: H STATE ENERGY CODE rV oe 041, FINAL ADDITIONAL C ,MMENTS C Z D t 1 r Grn -77P q rk \H O z d TOWN OF SOUTHOLD—BUILDING DEPARTMENT C31 Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631)765-9502 hqps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING P RMIT v 1 , r Office Use Only idi PERMIT NO. Building Inspector: 2021 -forms must be filled out'in their entirety..Ificomplete' -7, -4-�6pplic"6fi6n' s will,'noi:be accepted. Where theApplicant is,not the owner,an OwneesAuthorization form(Page 2)sha 1111be'completed. Date gel OWNER(S)OF PROPERTY: Name:__C,V SCTM#1000-6-yf C/ KI Project Address:-3-E— -T Phone#: Email: Mailing Address: tONTACT PERSON: Name. Mailing Address Phone#: -7- c Email: 'DESIGN PROFESSIONAL'INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: -Name: Mailing Address- Phone#: Email: DESCRIPTION OF PROPOSED-CONSTRUCTION AfNewStructure OAddition CAlteration []Repair ODemolition Estimated Cost of Project: DOther 000 W I the lot be re-graded? E]Yes EVNo Will excess fill be removed from premises? E]Yes/IgNo il 11"�Q 6�' OS�FFp��.l' BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD ® Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cDsoutholdtownny.gov - seandasoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: f Company Name: Electrician's Name: C Gej a W 6t Ao&),Ir,ai License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: hFV 4�e,,j c WNX sIG Z Address: -gt./.to ` Aovfv ,too Ab � f Cross Street: e �;�� lib Phone No.: g:/ Bldg.Permit#: email: Tax Map District: 1000 Section: (o Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO -]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service? MY RN Additional Information: PAYMENT DUE WITH APPLICATION /r BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 "O ^ Southold, New York 11971-0959. ® Telephone (631) 765-1802 - FAX (631)765-9502 ' r rogerrasoutholdtownny.gov - seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date:J-l—.rz2.;t— Company Name: Electrician's Name: 5 G> a 6,(AAffi/ 6 License No.: Elec. email: Elec. Phone No: El I'request an email.copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: &v i --e,,✓ c W#, v01 11-.r Address: VSgirla /lo,rfor favAll 4 ZZf Cross Street: pge „/14a Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: ro Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size Ell PhF-13 Ph Size: A # Meters Old Meter# F]New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect[—]Underground❑Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION /�� G9 PERMIT# Address: Switches 1 Outlets GFI's I Surface Sconces H H's Q� UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments 51TUATE150UT1q0LD / TPW � 50U'THOLD 5UFF0 GOUNTY.NY. Lk / �Id�FT2Di'.IA.Y,7B.;•7.0',O_'9;•�:�;�.::;.::�::'"•:•::f.�:' ..,�:� -�Qr fr+ :,I;.; :;,IGao,r64,::.4;:�@il';`•::.j::;;":.i+ir �i::.;S:''';:;:::::':C' `�� / ,y' ,i.'Q,,,`:.'�,:' . L�t'III%� 10!` J•. r.:. .WoaaLla,• w l•.' / c.r 'roan BomLotds t:S!:'. f fra�•eo• b .. .. ..,.r.. .,. .:....... ......., �.,,•.._..: •. ......•:�is:. '''•l*:�� •�:'i', 5y nr. L f r t r ....r:}r, Ili ,. .........r.::.. Y•�' t J / .ir�:�:i:;.+:, ;%'(• 4 r n:•• �p a p.r V: a. r. M 1 N.t` ,/ 'vA:`.". .rtl::.�Jr' Fii� r'�d✓ 1 ♦ ydL r�"1 ,.• �0� ,�,`::. 'F.iia...... �• dJ 1 mom AV oe .1 r A / h 1 7Q r ti ,Ori Grp �',`:;:1 i::::::Y• 1r' - 1 / / �� ✓/ � I ::•' ;,r::,Jr�'';`':fin?,.:'1`',;{r•9 1 / r aE x :r• r. r r J ss Y /r t / / rid•, I / / !,r / I Y A%'fir ✓• J J' , I \ / / r 1 / / / c.t•I'y S ��/. :.k•r y 1 r Q D / y:' J r S' r .R / 1 / r / 1 / r / •�I r / 1 +•h4 1.. / w. ti'•' I ✓ ,a5!'It r:•.: ltd :iiEWA r 4: 1 1 N r, !;��ili•'•::'t+'):::iii;,;;,.,t�i:.`::�+:` ,,�r. .z I sr 1 !R' ,i f ,t i• i!�(Iii:,.• y`r.r fj :hsy. fr,r. 9 /., � NOW 55 f 'S, fir ,k.;';• I "„r:..{r, raj•:' "a Ms.;:f'......... I J u•, v ,,,. { YP V a r.. .. r. , v. .. ... +., .. .r }•...,.... ...i.:.... :..:':` ::;,i• :..,fir. r. . " r.1 r... 1, ..,.,... �. .. r.. f..r t }✓ i. / r! fIsm11m Emu 9 ".r. ......:... .... ....... .. .. .,; r.: .., rr...e,. t. Ir m 1 tG f.r r, •3 r 1.. .r. f . ✓ 'O r.. r<, ,rn? nr 1 / a a,< 0 NPiE ;•: it. ;.1. 6 :fix, M 'f G SCALEJ � •a ) rJDI q' R POtMD r • T'1 r 1. 1 .: .. .. ... .. ....,r_ ..... .,... .. Q... •: dr. ., .... ..... ..� .., ,...• .... .. r ... .. ... ...., r...yr v. •� �� , ..... ... ........ .....a .. .".:.::..r.v':I:,.:.•,u,�rv,,,..:.. .. ... , r r.. rl A k '_< •h F, ,+ ._q.. _ Irl - ,Y^ ........... s A A22PPR VED AS NOTED D- I B.P.# J b-3 FEE:-44L. BY: NOTIFY BUILDING DEPARTMENT AT OCCUPANCY OR 765-1802 ' SAM TO 4P FOR THE USE IS UNLAWFUL FOLLOWING INSPECTIONS: 1 FORNDATION - TWOPOURED CONCRETE REQUIRED FOR WITHOUT CERTIFICATE 2.3. NOSULATION FRAMING & PLUMBING lJ OF OCCUPANCY 4. FINAL - CONSTRUCTION MUST r V BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. a rpn 4a rig COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF � toC minimum 56 1 414p r.701 Nj Rl ANNING BOARD S4 'HOI n TOWN TRUSTEES4I Q fel Vel 6n V �- BUILDER u 34 8' 8' 8' -I 8'- 1 '—DO IN I c a 2-2X10 MSR SYP N oLL TRUSS CARRIERS ❑� o ��� NEW BUILDING SPECIFICATIONS Z" 30' X 34' X 12'4" POST & FRAME GARAGE phi W/1-12'X34' OPEN LEAN-TO DID 0-18- X 8" CONCRETE FOOTINGS (TYP) DESIGN (5301 LB CAP; 5120 LB COLUMN WT) POST SAVER PATENTED UPLIFT NOTCHED POST W/12" o o 0. 0CONCRETE COLLAR I` Q) rn •o 3-3'0" X 6'8" 9-LITE FIBERGLASS ENTRY DOORS o Q - E 00 2 -8' X 9' SINGLE SLIDING DOORS 00 c a < a 3 3-36" X 44" THERMALPANE SINGLEHUNG WINDOWS o 0 Enr Y _J c m ® 3 PLY 2X6 GLULAM POSTS W/POST SAVER POST Q o O PROTECTION 8' OC (TYP) CE 0 o E Y f� 2X6 TREATED GROUND CONTACT SKIRT BOARD E M 0 3: w 0 2X4 SPRUCE WALL GIRTS & ROOF PERLINS 24" OC OWNER 2-2X10 MSR SYP TRUSS CARRIERS ®8' SPANS W 00 (991 PLF CAP; 640 PLF ROOF LOAD) 00 Y00 ALL GABLE POSTS TRUSS CARRIER TO POST= &"X4' GRK STRUCTURAL SCREWS V) 00 Lc) EXTEND TO TOP 8 ®EA.POST (2 PER SPLICE MIN) 2664 SHEAR RATING LL d OF ROOF TRUSS PRE-ENGINEERED ROOF TRUSSES- O W 4/12 PITCH, 48" OC, 30-5-5 LOADING Z I- 5 ROWS 2X4 BOTTOM CHORD TIES (57.28" OC.) V) _3 Z O 1080 LB UPLIFT; H-10A HURRICANE TIES=1340 LB W Q 12' EAVE OVERHANG W/VENTED SOFFIT & FLUSH GABLES () W/ 6" PAINTED STEEL RAKE TRIM 29 GA G-100 PAINTED STEEL ROOFING & SIDING 12" PAINTED STEEL VENTED RIDGECAP Iq Z O 2 2-2X10 MSR SYP 2 O (9 M W TRUSS CARRIERS O D IL W ALL INFORMATION SHOPN i �I i ON THIS ORANING IS THE 8 5 —7 8 ~I 3 —/" I~—U' �— PROPERTY OF SHIRK BUILDINGS LLC. 2-2X12 #1 SYP 3 4' THISEDRAWNG MAY NOT 5" BE REPRODUCEDWTHOUT TRUSS CARRIERSPERMISSION.BUILDER AND '`,ij1�901/dP1t/QtL OMER ARE RESPONSEI.E �,rV ,`y•r•'/�/' VERIFY CONSTRUCAIL OIMEN9ONSTION ' BEFORETO N 2X10 MSR SYP O ®e oRAvr+ev ALS RAFTERS 4' ON CENTER `��:'� �+f.=g`S REVISIONS: FLOOR PLANT ¢ y m 2-2X10 #1 SYP c') �c = DATE: 2/15/21 SCALE: 11 64" = 1'O" SITE:WESNOFSKE TRUSS CARRIERS / :2�,• s ••.077142A . I `` FLOOR PLAN �- 1 1'-4"— 1 1'-4" �- 1 1'-4" -� FESS101yA�.•��• ��i1/f lllllllll��' T 12 29 GA. PAINTED 4 STEEL 3 X 3 HEMMED L TRIM 36'x 44' 36'x 44' THERMAL PANE J'0'X 6'B' THERMAL PANE 3'0'TRY X 6'6' WINDOW y LITE WINDOW 9 LITE DOOR �/ D29 GA. OOR N ED STEEL �N N 11 11 1 29 GA. PAINTED BASEII In ., PIT .� STEEL ANGLE �o 6- CORNER TRIM BACK SIDEWALL LEFT ENDWALL SCALE: 1/8" = 1'0" SCALE: 1/8" = 1'0" 29 GA. PAINTED STEEL 29 GA 6" PAINTED 12" RIDGECAP(VENTED) STEEL RAKE TRIM 29 GA. PAINTED STEEL T 4 SCREWDOWN ROOF PANELS LIT 12 2� 36'x 44' THERMALOWPANE 3 9 X�6' ENTRY 7/ DOOR 8 X9 8 x9 N -IN SLIDING DOOR SLIDING DOOR CA 7 m FRONT SIDEWALL RIGHT ENDWALL �a�`+``a`� .�'O•••e•••y'y 'vo SCALE: 1/8" = 1'0" SCALE: 1/8" = 1'0" m ULU ELEVATIONS DRAWN BY: ALS ALL INFORMATION SHOWN 0 rT ON THIS DRAWNG IS THE c �INQ �u - REVIS ONS: PORE BUILD NGS SHIRK C. EUGENE WESNOFSKE James A. Koppenhaver, P.E.Zt;H E eU� THIS DRAWN MAY NOT 36450 ROUTE 48 304 Logan Ave BE REPRODUCED N7R AND Wyomissing, PA 19 610 ' PERMISSION.BUILDER AND DATE: 2/15/21 OWNER PECONIC NY 11958 Email; ko enhaver e@ mail.com PP P 9 807READINGROAD EA51"EARL PA17519 LLC SITE:WESNOFSKE BEFORE ALLCONSTRUCTION 717-445-6888 FAX 717-445-3001 _ • BUILDER u J 28 Gk STEEL R00 B NAILS 2%4 ROOF PLAUN 29 GA. PAINTED �a ROOF TRUSS PER TRUSS ROOF STEEL ROOFING 28 GA S RUCIURAL rT.RUSSI rMRERIP AINTED STEEL 'X.120 2%4 ROOF RDDF METAL WFATERTIIEK COVER STIR ROOF 2%4 GIRT OR PETNUN CNVNABS PURUN TRU 'DINGJTR WS24.ON CENTER 'GRK W�POST TBRAC ETSSIRUCIUR PlA �31-%�1Y05 PUCE 'NO PoH WS KROM / O X BUTRACK ILDINGLI ELR I WffATERTRE Z.o ODER GRAKE 1PoM9'ON CENTERSTRUCTURAL TALPAINTED SCREWSWALL POST METAL SDOORING q K POST SIOIN6 ORK STRUCTURAL YETALSIDING R ROOF PURLIN TRUSS SCREW TO POST SLIDINO DOOR RAKE TRIY ROOFING FASTENERS FASTENI� DETAIL DETAIL DETAIL WAUD CARtOER FASTENER DETAIL SCALE: 1/2-- 1'0- SCALE 1/2"- 1.O' SCALE: 1/2'- 1.0' SCALE: 1'- 1'0' SCALE: 1/2'- 1.0' DESIGN W O O a — U WALL POST PAINTED STEEL N 1p .o Wim-POST 2X4 WALL . � 2X4 ROOF PERUN DOOR JAMB POST2X.FACE BOARD � Q - E GALV.NAILS / p PER TRUSS R „• C- TR \ 2�'CALVAMZED CL \ DECK SCREWS FASCIA N O 0 CALV.NAILS CE 4 NAILS PER 28 GA.PAINTED STEEL I SOF TRU SOFFIT Y J C EACH SIDE CHANNEL F&J TRIM POSTTRUSS W CL Q 4 U1 a 2x8 n CARRIER METAL SIDING O '� 0 SIDEWALL DIRT BLOCK TRUSS TO TIE BLOCK ENTRY DOOR 12'EAVE OVERHANG CNC O FASTENING DETAIL FASTENER DETAIL JAY. DETAIL DETAIL L T'O SCALE: 1/2•- 1'0' SCALE: 1/2•- ID' SCALE 1/2'- 1'0- SCALE: 1/2•- 1.0- 2' W OWNER 2 ROOFING P NSTEILLLED W/ W PERMANENT OM CHORD SCREWS g WASHERSco TERAL BRACING(SENTEETRUSSv� co WG FOR SPACING) LL - 2X8 SPF 2%4 ROOF FACE BOARD Q LLJ r NS 24'OC. PAINTED 11 FROM 2X4 SPR��TO.1 MONAL E Z F.. FASCIA ROOF TRUSSES D N = Z VENTED 48'OC. WS N PRE-ENGINEEREDZFH-IGA HURRICANE CU PANELS 7 I.L. V TRUSSES 48.OC. STEEL W Q Z 2-2%10 MSR SW TRUSS CARRI IKUSS NOTCHED-F�TRIM Z Q }1 SYP TRUSS CARRIERS INTO POST W M 11 a W 3 PLY 2X6 GLU-LAM 2X4 SPF SIDEWALL GUM 24'OC. _ a. N Posrs e• OC. TYp. W r' WALL BRACING REGUTAL ENTS:STEL ALL INFORMATION SHOWN LS NS STRUCTURAL STEEL ON THS DRAWNG IS THE WALL BRACING PANELS INSTALLED IT EXTERIOR AWPA U1 TREATED POSTS 8'OC.TYP. PROPERTY OF SHIRK RECUIREMENTS: OF WALL PURLINS WITH SCREWS 2BGA STRIICIUIUIL POLE BUILDINGS LLC. STEEL SIDING THIS DRAWN.MAY NOT 2X4 SPF WALL CARTS 24'OC PANGS l6TAUID BE REPRODUCED WlHOUT WITH SCREWS PERMISSION.BUILDER AND GRADE GRADE IIIIIINIIifPI� RESPONSBUE TO VERIOWNER FY DIMENSIONS _- 4'-4000 PSI SYP SKIRT OARD PRESSURE TREATED `� OIC N ��y GRADE(BOTTOM RDOR SYP GROUND CONTACT �� i- rYC O BEFORE CONSTRUCTION OF ) ppryDNy,) 2%8 SKIRT BOARD �� ••• 00.04... �.rO�sDRAWN BY: ALS REVIEW: 3/4" ONE 8 •••• COMPACTED / \ \ \ �Y \ \ \ \ \ a� (' �/�i���I REVISIONS: / (OPnONJAL SOIL BAOOILL POST SAVER PATENTED UPLIFT NOTCHED Pasr w/12'OON�TE 30DD Pg.CONCIRFTE. POST W/12-CONCRETE I Y �;l/:Yi:Yi,%i FOOnNG(SEE SIZE\ / .� =r Q i' 3000 PSI.CONCRETE FOOD M y •I: �:: x�0000 PS F 501 �. ON FLOOR PLAN) /\ •., ,�� u 1 DATE: 2/15/21 (SEE SIZE ON FLOOR PLAN) '.. �,� ` •�:•`� /\� / I \ \ \\ \\ y \/\ \ \\ \ f'�"•.,: \/\ \/\/\ /\ '•,: � >r � ;(4/.` SITE:WESNOFSKE TYPICAL FRAME y \ \ �\/�`� \� /\\/\\\ ���1� SECTIONS SECTION / � ✓,\7 TYPICAL FRAME •. OT714`L (ENDWALL VIEW) a \ \\� \ SECTION •,. .•'•� �� SCALE: 1/4"L I 1'0" (SIDEWALL VIEW) 1 ,RO�ESSIO�A��•���` 3 SCALE: 1/4" = 1'0" ���itrerLnnlN`���� A . BUILDER J � J BUILDING DESIGN NOTES AND DETAILS A4.8 CONCRETE FLOOR(OPTIONAL) FIBER REINFORCED 4000 PSI CONCRETE SLAB ON GRADE OVER COMPACTED BASE. ^° A4.1 GRADING & EXCAVATION SLAB WILL BE POURED AGAINST SKIRTBOARD WITH NO TURN DOWN. z it I FINISHED GRADE SHALL BE BELOW FLOOR LEVEL WITH ADEQUATE FALL TO CARRY a SURFACE WATER AWAY FROM BUILDING. FOOTINGS SHALL BE CIRCULAR (UNLESS A4.9 STRUCTURAL DESIGN PARAMETERS NOTED OTHERWISE) AUGERED TO THE DEPTH AND DIAMETER SPECIFIED, WITH ALL BUILDING USE= STORAGE USE GROUP=U m Q mZ LOOSE FILL REMOVED BEFORE CONCRETE FOOTING MATERIAL IS PLACED. A RISK CATEGORY I o A4.2 FOOTINGS EXPOSURE CATEGORY= C d STANDARD DEPTH FOR FOOTING EXCAVATION IS 44" FROM FINSIH FLOOR HEIGHT HEIGHT & AREA LIMITATIONS=5B UNPROTECTED o a FOOTINGS SHALL BE A MINIMUM OF 36" DEPTH FOR FROST PROTECTION OR; OCCUPANCY LOAD=AS PER DESIGN LOCAL BUILDING CODE DEPTH REQUIREMENTS FOR FROST PROTECTION WILL BE TOTAL NUMBER OF FLOORS= 1 m FOLLOWED. DRY,MIX CONCRETE HYDRATED IN-SITU WILL BE USED UNLESS TOTAL FLOOR AREA (SQ FT)=1020 OTHERWISE SPECIFIED. BUILDING VOLUME (CU FT)=14,900 DESIGN A4.3 FRAMING LLJ E LUMBER FOR SIDEWALL GIRTS AND PERLINS SHALL BE #2 SPRUCE OR COMPARABLE. STRUCTURE IS DESIGNED FOR ASCE 7-10 ULTIMATE WIND SPEED, VULT=130 MPH O o (3 SECOND GUST) AND NOMINAL DESIGN WIND SPEED VASD=103 MPH. LD - LUMBER FOR SKIRTBOARD, POSTS AND BEAMS SHALL BE #2 OR BETTER SOUTHERN L Q) 0) 0 a> E YELLOW PINE. TIMBERVALUES FOR 3 PLY 2X6 GLU-LAM :FB=2150, FC=2050. LUMBER SOIL BEARING CALCULATIONS ARE BASED ON SOIL BASE CONDITION 3000 PSF > - > Q rn FOR TRUSS CARRIERS SHALL BE #1 OR BETTER SOUTHERN YELLOW PINE. ALL GROUND @48" BELOW GRADE UNLESS NOTED OTHERWISE. 0 CONTACT LUMBER SHALL BE TREATED TO AWPA U1-09 (COMMODITY SPECIFICATION A, 30 PSF(LIVE) MIN.SNOW; 5 PSF TOP CHORD & 5 PSF BOTTOM CHORD LOADS. c o a USE CATEGORY 4B AND SECTION 5.2) AND ASAE(ASABE)EP559, .60 CCA MINIMUM AND A4.10 APPLICABLE BUILDING CODES o- o ° SHALL BEAR AN ACCREDITED LABEL USING #1 OR BETTER SYP. Y J A4.4 ROOF TRUSSES THESE PLANS ARE DESIGNED IN ACCORDANCE WITH THE FOLLOWING BUILDING CODES: a 2020 BUILDING CODE OF NEW YORK STATE AND ASCE 7-10 ROOF TRUSSES SHALL BE PRE-ENGINEERED. GROUND SNOW LOAD, DRIFT LOAD, O $ COLLATERAL LOAD, AND WIND LOAD ARE TO BE IN ACCORDANCE WITH BUILDING CODE. A4.11 DESIGN REFERENCES: Q) "' 0 TRUSS ERECTION AND BRACING SHALL BE PROVIDED ACCORDING TO MANUFACTURERS E -6 NFBA GUIDLINES FOR POST & FRAME CONSTRUCTION 0 3: E SPECIFICATIONS. BOTTOM CHORD OF TRUSS SHALL HAVE PERMANENT LATERAL BRACINGw AMERICAN WOOD COUNCIL 2018 NDS & WFCM 2018 FOR WOOD CONSTRUCTION OF 120" OC. OR AS REQUIRED PER ROOF TRUSS DESIGN. THE DESIGN PROFESSIONAL OF SOUTHERN PINE COUNCIL (JOISTS & RAFTERS/ HEADERS & BEAMS) OWNER RECORD HAS REVIEWED THE PRE-ENGINEERED ROOF TRUSS DRAWINGS AS PER R502.11.1 w AMERICAN NATIONAL STANDARDS (ANSI 117-2010) & IBC 107.3.4.1 AND THEY COMPLY WITH THE STRUCTURAL DESIGN REQUIREMENTS. H SOUTERN BUILDING CODE CONGRESS (SSTD10) � co 00 Lo A4.5 ROOF TRUSS UPLIFT AND LATERAL CONNECTIONS ASCE MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES co07 PRIMARY ROOF TRUSSES SHALL BE CONNECTED TO THE SIDE OF THE STRUCTURAL POSTS GEORGIA PACIFIC ENGINEERED LUMBER (EDITION 10) LL AND INTERMEDIATE ROOF TRUSSES SHALL BE CONNECTED TO THE STRUCTURAL HEADER O Lu r WITH UPLIFT BLOCKS WITH A SUFFICIENT NUMBER OF FACE NAILS TO OFFSET THE WIND A4.12 WARRANTY NOTES Z F- >. UPLIFT FACTOR AND LATERAL LOADS NOTED ON THE ROOF TRUSS DRAWING IN U) = Z ACCORDANCE WITH IBC SECTION 2304.9.1, 2308.10.1, AND 2308.10.6 ANY DESIGN MODIFICATION OR ANY STRUCTURAL MODIFICATION BEFORE, DURING, OR W 0 A4.6 FASTENERS AND FRAMING CONNECTIONS STRUCTURE COMPLIES WITH ASAE(ASABE) AFTER CONSTRUCTION TO BUILDING BY ANY PERSON(S) OR COMPANY OTHER THAN V EP484 DIAPHRAM DESIGNS& ACTIONS FOR METALCLAD BUILDINGS, IBC WIND BRACING WORK PERFORMED OR APPROVED BY SHIRK POLE BUILDINGS LLC WILL VOID ANY AND REQUIREMENTS, IBC CONSTRAINED/ UNCONSTRAINED POST REQUIREMENTS& POST TO ALL WARRANTIES PROVIDED BY MANUFACTURERS AND/OR SHIRK POLE BUILDINGS LLC. Z Lo 0 FOOTING CONNECTION. ALL FRAMING CONNECTIONS SHALL BE OF A SIZE AND DESIGN SUCH DESIGN MODIFICATIONS AND/OR STRUCTURAL MODIFICATIONS INCLUDE: I V TO MEET DESIGN LOADS SPECIFIED, NAILS USED IN .60 ACQ/CCA TREATED WOOD DRILLING, REMOVING, CUTTING, SAWING, SPLINTERING OR DAMAGING ANY w M W SHALL BE 12D HOT DIPPED GALVANIZED; ASTM A 153 PLATED 1.2 MIL SCREWS, AND A STRUCTURAL MEMBERS INCLUDING FOOTINGS, POSTS, GIRTS, BEAMS, TRUSSES, w 65 CLASS G 185 HARDWARE. THE MINIMUM AMOUNT OF 12D NAILS IN 2X4 ROOF PERLINS, PANELS, WINDOWS, DOORS, NAILS, SCREWS, AND BOLTS. PERLINS IS 2. THE MINIMUM AMOUNT OF 12D NAILS IN 2X4 WALL GIRTS IS 3. THE SUCH DESIGN MODIFICATIONS AND/OR STRUCTURAL MODIFICATIONS ALSO INCLUDE: W MINIMUM # OF 12D NAILS IN 1i" STRUCTURAL TIMBER IS 1 PER J" BOARD WIDTH. ADDING ADDITIONS, SNOW DRIFT LOAD FROM ADDITIONS, LEAN-TO'S, ATTIC ALL INFORMATION SHONN STORAGE, CHAIN HOISTS, OPENINGS, SKYLIGHTS, ROOF VENTS, AND LOUVERS. ON THS DRAWNG IS THE TRUSS CARRIER CONNECTION TO POST: "x4" GRK RSS STRUCTURAL SCREWS. SCREW PROPERTY OF SHIRK VALUES; LATERAL DESIGN VALUE=333 LB, TENSILE STRENGTH=139,000 PSI, SHIRK POLE BUILDINGS LLC WILL NOT BE LIABLE FOR ANY FAILURES RESULTING POLE BUILDINGS LLC, FROM THOSE MODIFICATIONS LISTED ABOVE, OR FROM ANY OTHER MODIFICATIONS THIS DRANINO MAY NOT PULLOUT=2644 LBS, HEAD PULL THROUGH=825 LBS, MIN. BENDING ANGLE=35' DE REPRODUCED NITHOUT NOT APPROVED BY A CERTIFIED ENGINEER. 1131911141#/ PERMISSION.BUILDER AND A4.7 METAL SIDING AND ROOFING METAL SIDING AND ROOFING SHALL BE INSTALLED ��! 14F, OWNER ARE RESPONSIBLE WITH #9 WOODGRIP, J" HEX HEAD, METAL AND RUBBER WASHERED GALVANIZED `fit®off or,Np *0v.' 13EFORII�CONSTRUCTION COLOR MATCHING SCREWS. FASTENERS SHALL COMPLY WITH THE ROOFING & SIDING `tio' ��• •.o 10 .1� DRAWN BY: ALS MFG'S REQUIREMENTS, METAL SIDING AND ROOFING SHALL BE WARRANTED a ,' �';9 REVIEW: #1 GRADE 80,000 PSI MIN. TENSILE STRENGTH CORRUGATED 28 GAUGE PAINTED (V� 'S';� '�, REVISIONS: ABM STEEL PANELS GALVANIZED TO A MINIMUM OF G-100. c1` �G„ p METAL SIDING AND ROOFING SHALL BE TRIMMED WITH CORRECT FLASHINGS AT = Q d Rigcc EXPOSED EDGES, ROOF ENDS, CORNERS, DOORS, WINDOWS AND RIDGES, EXCEPT; "�n �: LU BOTTOM EDGE OF STANDARD ROOFING MATERIALS. In =W DATE: 2/15 21 `' SITE:WESNOFSKE 4�CAO --.077142- �.• ,� DETAILS k4 '� Mfr sst BUILDER u J O p �a ROOF TRUS m X 2X10 MSR SYP 2X12 #1 SYP ¢LL TRUSS CARRIER RAFTER PLATE XUZ Z� o� �^ • DESIGN W o0 a_ �- U 34"X.120 GALV. 2-A"X4" GRK STRUCTURAL > NAILS SPACED SCREWS INTO EACH 6"OC. BETWEEN TRUSS HEEL a a TRUSSES 0oJ d 'co a o 'E $ o _ T'o E w OWNER W Y o Lo u. � � O w r- I-- WALL POST W O= Z 3'. wU Lu 0 Z It* Lu to 0 C7 M w � a w ALL INFORMATION SHOWN ON THIS DRAHING IS THE PROPERTY OF SHIRK POLE BUILDINGS LLC. THIS DRAWING MAY NOT BE REPRODUCED WTHOUT PERMISSION.BUILDER AND OVMER ARE RES'CNSIB E TO VERIFY ALL DIMENSONS offl BEFORE CONSTRUCTION `�� ' ��••••••• ti �,�sj� DRAWN BY: ALS LEAN - TO RAFTER ��•, .,09 REVIEW: ` �/� .� REVISIONS: PLATE TO BUILDING CONNECTION =m :¢ DATE: 2/15/21 LU SITE:WESNOFSKE SCALE: 3/8" = 1 '0" _` RAMING DETAILS ••.0Tj142:•'4. �� ''��� i��fiEsslot, ������� Job Truss Tmss Type Qty Ply . 21021521 B T30 COMMON 1 1 Job Reference(optional) UFP,UFP 20/20 Run:8.410 s Jun 25 2020 Print:8.410 s Jun 25 2020 MiTek Industries,Inc. Mon Feb 15 16:10:05 2021 Page-1 ID:4CNMpKig E7rU7vsl4EhaQ2zks9Z-1 s1 YogxblyEovgpxhjW 1 h2BZ8p1 ZGkBvEk6k3czks9G �0-10-$ 7-10-14 15-0-0 22-1-2 30-0-0 1-10— 7-1-2 7-1-2 7-10-14 Sale-1:48.5 4.00 72 8x6= 5.8 4 18 9 2X3\\ 2)0// 3 17 1 2 7 10 9 8 4x4= 012 MT20H5= 4x4= 4x8= 4x8= 10-3-4 19-8-12 30-0-0 10-3-4 9-5-8 10-3-4 Plate Offsets X Y-- [5:0-3-0,0-3-81,[8:0-1-8,0-1-121, 10:0-1-8,0-1-12 LOADING(psf) SPACING- 4-0-0 CSI. DEFL. in floc) Vdefl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.15 TC 0.61 Vert(LL) -0.33 8-10 >999 240 MT20 197/144 (Roof Snow=30.0) Lumber DOL 1.15 BC 0.80 Vert(CT) -0.51 8-10 >711 180 MT20HS 148/108 TCLL 5.0 Rep Stress Incr NO WB 0.57 Horz(CT) 0.16 7 n/a n/a BCLL 0.0 Code IBC20181TPI2014 Matrix-MS Weight:134 Ib FT=20% BCDL 5.0 g LUMBER- BRACING- TOP CHORD 2x6 SP 240OF 2.0E TOP CHORD 2-0-0 oc purlins(3-11-0 max.). BOT CHORD 2x4 SPF 210OF 1.8E BOT CHORD Rigid ceiling directly applied or 4-9-5 oc bracing. WEBS 2x4 SPF No.2 REACTIONS. (Ib/size) 2=2492/0-8-8,7=2399/0-8-8 Max Horz2=233(LC 12) Max Uplift2=-1080(LC 8),7=-1000(LC 9) FORCES. (lb)-Maximum Compression/Maximum Tension TOP CHORD 1-2=0/29,2-17=-5737/2892,3-17=-5614/2909,3-4=-4928/2584,4-18=-4783/2586,5-18=-4758/2601,5-19=-4762/2619,6-19=-4933/2604,6-20=-5605/2936, 7-20=-5715/2920 BOT CHORD 2-10=-2587/5326,9-10=-1611/3568,8-9=-1611/3568,7-8=-2617/5335 WEBS 3-10=-1 449/817,5-10=-659/1697,5-8=-663/1703,6-8=-1454/820 NOTES- 1)Wind:ASCE 7-16;Vult=130mph(3-second gust)Vasd=103mph;TCDL=3.Opsf;BCDL=3.Opsf;h=20ft;Cat.II;Exp C;Enclosed;MWFRS(envelope)gable end zone and C-C Exterior(2E)-0-7-13 to 3-4-3,Interior(1)3-4-3 to 11-0-0,Exterior(2R)11-0-0 to 19-0-0,Interior(1)19-0-0 to 26-0-0,Exterior(2E)26-0-0 to 30-0-0 zone;C-C for members and forces &MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL:ASCE 7-16;Pf=30.0 psf(Lum DOL=1.15 Plate DOL=1.15);Is=1.0;Rough Cat C;Partially Exp.;Ce=1.0;Cs=1.00;Ct=1.20 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 5)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf(or less)is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load. 6)All plates are MT20 plates unless otherwise indicated. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1080 Ib uplift at joint 2 and 1000 Ib uplift at joint 7. 9)This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 10)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable,or consult qualified building �F NE designer. �f/r 11)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard COq2. C) 1 rQ135. 9�F�SsioNP.'- 02/15/2021 3 4' BUILDER J 8'�� 8' 8'--I�I �� 8'— i6 0 6 -1 - - 4r:: 1 + z �a a 2-2X10 MSR SYP-// ['M m X TRUSS CARRIERS ON� //ILr\^/lJI )` ° NEW BUILDING SPECIFICATIONS ^�� z y `� y lK 30' X 34' X 12'4" POST & FRAME GARAGE A W/1-12'X34' OPEN LEAN-TO a0 APR 1 2 2021 0-18" X 8" CONCRETE FOOTINGS (TYP) DESIGN (5301 LB CAP; 5120 LB COLUMN WT) y LLI POST SAVER PATENTED UPLIFT NOTCHED POST W/12" CL: o CONCRETE COLLAR ` ;?-` '" '' '� t- a� CO 02-3'0" X 6'8" 9-LITE FIBERGLASS ENTRY DOORS `' "' "' i'`ate" ' �I''' °� E 9 1'. �.._ .... .... ._ ri..: > Q rn 002 -8' X 9' SINGLE SLIDING DOORS CC) a o n 3 5. 3 -36" X 44" THERMALPANE SINGLEHUNG WINDOWS rn a ® 3 PLY 2X6 GLULAM POSTS W/POST SAVER POST O PROTECTION 8' OC (TYP) o E 2X6 TREATED GROUND CONTACT SKIRT BOARD 0>,-6 2X4 SPRUCE WALL GIRTS & ROOF PERLINS 24" OC ,g ® o � 2-2X10 MSR SYP TRUSS CARRIERS 08' SPANS — 1//�/� -D w (991 PLF CAP; 640 PLF ROOF LOAD) OWNER TRUSS CARRIER TO POST= &"X4" GRK STRUCTURAL SCREWS W 8 OEA.POST (2 PER SPLICE MIN) 2664 SHEAR RATING Y 00 ALL GABLE POSTS PRE-ENGINEERED ROOF TRUSSES- f LL. 00 EXTEND TO TOP 4/12 PITCH, 48" OC, 30-5-5 LOADING r O W OF ROOF TRUSS 5 ROWS 2X4 BOTTOM CHORD TIES (57.28" OC.) Z 1080 LB UPLIFT; H-10A HURRICANE TIES=1340 LB 12" EAVE OVERHANG W/VENTED SOFFIT & FLUSH GABLESCCE U) M Z W/ 6" PAINTED STEEL RAKE TRIM W O 29 GA G-100 PAINTED STEEL ROOFING & SIDING j w V 4'WAINSCOT BASE COLOR W p z 12" PAINTED STEEL VENTED RIDGECAP Z Lf) O i� 29 GAUGE PAINTED STEEL CEILING IN LEAN-TO W V 0X10 MSR SYP 0 M W TRUSS 5SS CARRIERS O. W ALL INFORMATION SHOWN 5'—7" 8'— 3'—7" I 8'~ ON THIS DRAWING IS THE PROPERTY OF SHIRK POLE BUILDINGS LLC. 2-2X12 #1 SYP 34' PETHIS OR�ODNG MAY NOT 5" " PERMISSIOONU�ER AAND TRUSS CARRIERS OWNER ARE RESPONSIBLE 010111111111#11 TO VERIFY ALL DIMENSIONS `\Niv, BEFORE ALL \ OF 2X10 MSR SYP NF�� o \\ •.w..,, r Imo' DRAWN BY: ALS N N �� \�\ .• '•.� �i RAFTERS 4' REVIEW:ON CENTER �;c, 'Gy:?'��= REVISIONS: FLOOR PLAN =r- ¢ M.- 2-2X10 .-2-2X10 #1 SYP DATE: 2/15/21 TRUSS CARRIERS SCALE: 11/64" = 1'0" 'ZiP'• _: SITE:WESNOFSKE '��O •, 771 AZ .•' FLOOR PLAN ---- A . 1 --- 11'-4" 11'-4" 11'-4"�I T 12 29 GA. PAINTED 4 STEEL 3 X 3 HEMMED L TRIM 29 GA. PAINTED STEEL THERMAL PANE THERMAL PANE WINDOW 3'9"x 6'• WALL PANELS wlNDow ENTRY ° DOOR N SIN I 29 GA. PAINTED BASE O STEEL ANGLE 6" CORNER TRIM BACK SIDEWALL LEFT ENDWALL SCALE: 1/8" = 1'0" SCALE: 1/8" = 1'0" 29 GA. PAINTED STEEL 29 GA 6" PAINTED 12" RIDGECAP(VENTED) STEEL RAKE TRIM 29 GA. PAINTED STEEL .r 4 SCREWDOWNROOF11 11 11 11 11 11 PANELS 11 11 11 11 11 1 to 12 gift, 2� 36'x 44' THE�MADL SANE 3 9 LITE ENTRY DOOR 8 x 98 x 9 ivIN SLIDING ��SLUN, 0 ��' m D 1111 EM 0 °Q OF jai �U; ", FRONT SIDEWALL ���� • �YDi� RIGHT ENDWALL SCALE: 1/8" = 110" ` � �• tiy����% SCALE: 1/13" = 1'0" .r ¢ s m•Q = �'�,�� '. 7714?:�•� �: ELEVATIONS DRAWTJ BY: ALS ALL INFORMATION SHOWN O TT ED REVIEW:- PROPEON THIS DRAVr1NGIS THEHIRK EUGENE WESNOFSKE m James A. Koppenhaver, P.E.Z9H11WKLL;Cu Po,,Ee�,�p o PROPERTY OF SHIRK r REVISIONS: POLE BUILDINGS LLC. � L� THIS DRAWING MAY NOT 36450 ROUTE 48 304 Logan Ave cs A <1 2BE REPRODUCED YER AND Wyomissing PA 19 610PERMISSION.BUILDER AND �DATE: 2 15 21 TO ER ARE L DIMENSIONS PECONIC NY 11958 Email; ko enhaver e@ mail.com To VERIFY ALL DIMENSIONS � P P P 9 807 READING ROAD EAST"EARL,PA 17519 SITE:WESNOFSKE BEFORE CONSTRUCTION 717-445-6888 FAX 717-445-3001 BUILDER J 28 GA.PAINED o STEEL ROOFING 2X4 ROOF PEITLIN N o PER TRUSS ROOF 28 CA PAINTED d'^ ROOF TRUSS m••1-1e-c-�\ STFEI.ROOFING i RING 28 GA STRUCTURAL 3-3j-X.120 2X4 ROOF ` ROOjFk& WEAIERRIE ROOF E STRIP 2X4 TINT DRSPE ELLIN GALV.NAILS PURUN P SCREWS SCREWS 24.ON CENTER �'X4-GPof WALL POSTTRACKX6 C ETS �VERTRACK m x PlA Lf'o, E IMO PED TRUSS STRucnxK 2 BACK / O BUDDING •IST F1AN 1'WEATERTITE RAKE TRIM TRACK dX, G� PAINTED SCREWS GABLE IN CHANNEL B.ON CENTER STRUCTURAL SLIDING METALoWALLGA PAINTED POST ME DOOR SIDINGPOST STEEL SIDING SIDINat YETAL SIOINO ! ROOF PURLIN DIRK STRUCTURAL SLIDING DOOR RAKE TRIP LEANTO DETAIL TRUSS SCREW TO POST ROOFING FASTENERS FASTEN DETAIL 1 CARSYPRIER DETAIL DETAIL n SMALF.r +,0, CARRIER FASTENER DETAIL SCALE. 1/2-- 1'0• SCALE 1/2'- 1'0' SCALE: 1/2'- 1'0• SCALE: 1•- 1'0• SCALE: 1/2"- 1'D• DESIGN W O O T1. r U WALL POST PAINTED STEEL (c)ROOFING Q) .o WMT.POST 2X4 ROOF PERLIN DOOR JAMB 2X8 FACE BOARD Q GALV.NAILS / GIRi� PER �TRUSS R r CEJ •.C 1R PANTED -r- EACH \ \i ECK SCREWS FASCIA p GALV.""" •• CE 4 NAILS PER T8 GA.PAINTED SIM L R00F TR Y.pCD C �TRUSSE POST FA:J 7PoM 2X6 71 CARRIER METAL SIDING O s SIDEWALL GIRT co rl) BLOC( TROSS T%TIE BLOCK ENTRY DOOR 12'EAVE�VERHANG O FASTENING DETAIL FASTENER DETAIL JAMB DETAIL DETAIL E T.O SCALE: 1/2-- 1.0' SCALE: 1 2•- 1'0' SCALE: 1 2•- 1.0- SCALE: 1 2•- 1'0' O � E w 28 GA. AINTED STEEL SCCREEWSP&INSTALLED RS OWR 2X4 BOTTOM CHORD Y� co PERMANENT LATERAL BRACING (SEE TRUSS vI co Lo IN FOR SPACING)AL 2%8 SPF 2X4 ROOF FACE BOARD O W r URUNS 24.OC. PAINTED If 2X4 SPF DIAGONAL BRACE Z FROM RIDGE IE TO EEIM FAM '^ FASCIA ROOF TR TRUSSESU)D v+ Z VENTED 48 OC. W O ER LAM PRE-ENGINEEREDZFH-IGIA HURRICANE CUPS PANELS U TRUSSES 48.OC. STEEL W Z 2-2X10 MSR Sr TRUSS CARRI FhJ TRIM Z Lo o TRUSS NOTCHED— I* /1 SYP TRUSS CARRIERS--- INTO POST W to I� BMW 3 PLY 2X8 GLU-LAM 2X4 SPF SIDEWALL CIRTS 24.OC. _ EL N POSTS B' OC. TYP. W WALL BRACING REGIU EMM-. . 29 GA'STRUCTURAL STEEL ALL INFORMATION SHOWY WALL BRACING PANS INSTALLED TO EKIERIOR AWPA U1 TREATED POSTS W OC.TYP. ON THIS DRAWING IS THE REGUIREMEN75: OF WALT.PURLINS WITH SCREWS PROPERTY OF SHIRK 28GA SiRUCIUWY. POLE BUILDINGS LLC. STEEL SIDING THIS DRAIMNG MAY NOT 2X4 SPF WALL GIRTS 24.OC PANES IS um BE REPRODUCED WITH. WITH SCREWS PERMISSION.BUILDER AND GRADE GRADE OKNER ARE RESPCN9BIE ro VERIFY ALL DIMENSION 2X8 PRESSURE TREATED PRESSURE TREATED ``��00111 1111#1 � BEFORE CONSTRUCTION S GRADE(BOTTOM 4•-4000 PSI SYP SKIRT BOARD f� �I DRAW)BY: ALS OF ) Ej p ) 2X8 SKIRT BOARD `��� ...•• .."� P. /� ..... `��� • ~• ���� REVIEW: 3/4•STONE flfl.�S� 'COMPACTED \ \\/\ \/\ \/\ \/\��\\ /\//\\/\ \ \//\ y;�� '�•• = REVISIONS: (OPTIOWIL) I. SOIL BACK•ILL e \ /�\/ GO 00 5A PA 3000 PSL CONCREIE� / \ - S L:1'� POST SAVER PATENTED UPLIFT NOfgfD P06T POST w/1z•CONCRETE W/12•MY MIX CONCRETE OOl1AR I Y �• Y/?Y/:Y/?%/2Y Y FOOTING (SEE SIZE+ �:W r•c / / /��; r.. ? M ..� �\3000 PSF SOIL / �!: i ON FLOOR PLAN) / Stn DATE: 2/15/21 3000 PSI.DRY MIX CONCRETE Y/\ 'I: �/ y/Y/� \ s:: /�/ / / 1: c:: _`. FOOTING SEE SIZE ON FLOOR PLAN ( •x;,::•f \ 'i \ / / SITE:WESNOFSKE ( ) v \\� Y\�\\\ \ t::; \y\ \y yam\ \ \ \\ 'y'0' �'+•, i�O •.OT7....".0 SECTIONS TYPICAL FRAME /\ T / TYPICAL FRAME //\\//\/ ''r� 1++.•"•••••' �� (ENDWALLSECTIOVIEW) a \ \ \ \ \i�\ SECTION \\7\\i� pr,OFESSIO�`����� (SIDEWALL VIEW) +++++1111ii111 SCALE: 1/4" = 1'0" SCALE: 1/4" = 1'0" o ' BUILDER BUILDING DESIGN. NOTES AND DETAILS A4.8 CONCRETE FLOOR(OPTIONAL) J FIBER REINFORCED 4000 PSI CONCRETE SLAB ON GRADE OVER COMPACTED BASE. ^° A4.1 GRADING & EXCAVATIONS LAB WILL BE POURED AGAINST SKIRTBOARD WITH NO TURN DOWN. FINISHED GRADE SHALL BE BELOW FLOOR LEVEL WITH ADEQUATE FALL TO CARRY SURFACE WATER AWAY FROM BUILDING. FOOTINGS SHALL BE CIRCULAR (UNLESS A4'9 STRUCTURAL DESIGN PARAMETERS 9 NOTED OTHERWISE) AUGERED TO THE DEPTH AND DIAMETER SPECIFIED, WITH ALL BUILDING USE= STORAGE m o� LOOSE FILL REMOVED BEFORE CONCRETE FOOTING MATERIAL IS PLACED. USE GROUP=U , RISK CATEGORY I o A4.2 FOOTINGS EXPOSURE CATEGORY= C STANDARD DEPTH FOR FOOTING EXCAVATION IS 44" FROM FINSIH FLOOR HEIGHT HEIGHT & AREA LIMITATIONS=5B UNPROTECTED a FOOTINGS SHALL BE A MINIMUM OF 36" DEPTH FOR FROST PROTECTION OR; OCCUPANCY LOAD=AS PER DESIGN LOCAL BUILDING CODE DEPTH REQUIREMENTS FOR FROST PROTECTION WILL BE TOTAL NUMBER OF FLOORS= 1 ^ FOLLOWED. DRY MIX CONCRETE WILL BE USED UNLESS OTHERWISE SPECIFIED. TOTAL FLOOR AREA (SQ FT)=1020 BUILDING VOLUME (CU FT)=14,900 DESIGN A4.3 FRAMING L STRUCTURE IS DESIGNED FOR ASCE 7-10 ULTIMATE WIND SPEED, VULT=130 MPH d O o LUMBER FOR SIDEWALL GIRTHS AND PERLINS SHALL BE #2 SPRUCE OR COMPARABLE. (3 SECOND GUST) AND NOMINAL DESIGN WIND SPEED VASD=103 MPH. UD LUMBER FOR SKIRTBOARD, POSTS AND BEAMS SHALL BE #2 OR BETTER SOUTHERN i Q) M ° YELLOW PINE. TIMBERVALUES FOR 3 PLY 2X6 GLU-LAM :F6=2150, FC=2050. LUMBER SOIL BEARING CALCULATIONS ARE BASED ON SOIL BASE CONDITION 3000 PSF a> > ,- E > Q rn FOR TRUSS CARRIERS SHALL BE #1 OR BETTER SOUTHERN YELLOW PINE. ALL GROUND ®48" BELOW GRADE UNLESS NOTED OTHERWISE. s c 30 PSF(LIVE) MIN.SNOW; 5 PSF TOP CHORD & 5 PSF BOTTOM CHORD LOADS. c Q a CONTACT LUMBER SHALL BE TREATED TO AWPA U1-09 (COMMODITY SPECIFICATION A, a) o O_ USE CATEGORY 4B AND SECTION 5.2) AND ASAE(ASABE)EP559, .60 CCA MINIMUM AND A4.10 APPLICABLE BUILDING CODES CD- o ° SHALL BEAR AN ACCREDITED LABEL USING #1 OR BETTER SYP. Y J c WIT A4.4 ROOF TRUSSES THESE PLANS ARE DESIGNED IN ACCORDANCE THE FOLLOWING BUILDING CODES: 2020 BUILDING CODE OF NEW YORK STATE AND ASCE 7-10 d ,� ° ROOF TRUSSES SHALL BE PRE-ENGINEERED. GROUND SNOW LOAD, DRIFT LOAD, O 0 COLLATERAL LOAD, AND WIND LOAD ARE TO BE IN ACCORDANCE WITH BUILDING CODE. A4.11 DESIGN REFERENCES: ° TRUSS ERECTION AND BRACING SHALL BE PROVIDED ACCORDING TO MANUFACTURERS T° NFBA GUIDLINES FOR POST & FRAME CONSTRUCTION o E SPECIFICATIONS. BOTTOM CHORD OF TRUSS SHALL HAVE PERMANENT LATERAL BRACING AMERICAN WOOD COUNCIL 2018 NDS & WFCM 2018 FOR WOOD CONSTRUCTION — w OF 120" OC. OR AS REQUIRED PER ROOF TRUSS DESIGN. THE DESIGN PROFESSIONAL OF SOUTHERN PINE COUNCIL (JOISTS & RAFTERS/ HEADERS & BEAMS) OWNER RECORD HAS REVIEWED THE PRE-ENGINEERED ROOF TRUSS DRAWINGS AS PER R502.11.1 uu AMERICAN NATIONAL STANDARDS (ANSI 117-2010) & IBC 107.3.4.1 AND THEY COMPLY WITH THE STRUCTURAL DESIGN REQUIREMENTS, Y 10 A4.5 ROOF TRUSS UPLIFT AND LATERAL CONNECTIONS SOUTHERN BUILDING CODE CONGRESS (SSTD10) U) 00 Ln PRIMARY ROOF TRUSSES SHALL BE CONNECTED TO THE SIDE OF THE STRUCTURAL POSTS ASCE MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES LL q AND INTERMEDIATE ROOF TRUSSES SHALL BE CONNECTED TO THE STRUCTURAL HEADER GEORGIA PACIFIC ENGINEERED LUMBER (EDITION 10) O W r WITH UPLIFT BLOCKS WITH A SUFFICIENT NUMBER OF FACE NAILS TO OFFSET THE WIND Z (— UPLIFT FACTOR AND LATERAL LOADS NOTED ON THE ROOF TRUSS DRAWING IN A4.12 WARRANTY NOTES (/) D Z ACCORDANCE WITH IBC SECTION 2304.9.1, 2308.10.1, AND 2308.10.6 ANY DESIGN MODIFICATION OR ANY STRUCTURAL MODIFICATION BEFORE, DURING, OR Lu O A4.6 FASTENERS AND FRAMING CONNECTIONS STRUCTURE COMPLIES WITH ASAE(ASABE) AFTER CONSTRUCTION TO BUILDING BY ANY PERSON(S) OR COMPANY OTHER THAN V EP484 DIAPHRAM DESIGNS& ACTIONS FOR METALCLAD BUILDINGS, IBC WIND BRACING WORK PERFORMED OR APPROVED BY SHIRK POLE BUILDINGS LLC WILL VOID ANY ANDW C Z REQUIREMENTS, IBC CONSTRAINED/ UNCONSTRAINED POST REQUIREMENTS& POST TO ALL WARRANTIES PROVIDED BY MANUFACTURERS AND/OR SHIRK POLE BUILDINGS LLC. L() FOOTING CONNECTION. ALL FRAMING CONNECTIONS SHALL BE OF A SIZE AND DESIGN SUCH DESIGN MODIFICATIONS AND/OR STRUCTURAL MODIFICATIONS INCLUDE: LLu t TO MEET DESIGN LOADS SPECIFIED. NAILS USED IN .60 ACQ/CCA TREATED WOOD DRILLING, REMOVING, CUTTING, SAWING, SPLINTERING OR DAMAGING ANY 0 M Lu SHALL BE 12D HOT DIPPED GALVANIZED; ASTM A 153 PLATED 1.2 MIL SCREWS, AND A STRUCTURAL MEMBERS INCLUDING FOOTINGS, POSTS, GIRTS, BEAMS, TRUSSES, = a 65 CLASS G 185 HARDWARE. THE MINIMUM AMOUNT OF 12D NAILS IN 2X4 ROOF PERLINS, PANELS, WINDOWS, DOORS, NAILS, SCREWS, AND BOLTS. Lj PERLINS IS 2. THE MINIMUM AMOUNT OF 12D NAILS IN 2X4 WALL GIRTS IS 3. THE SUCH DESIGN MODIFICATIONS AND/OR STRUCTURAL MODIFICATIONS ALSO INCLUDE: MINIMUM # OF 12D NAILS IN 14" STRUCTURAL TIMBER IS 1 PER J" BOARD WIDTH. ADDING ADDITONS, SNOW DRIFT LOAD FROM ADDITIONS, LEAN-TO'S, ATTIC ALL INFORMATION SHom STORAGE, CHAIN HOISTS, OPENINGS, SKYLIGHTS, ROOF VENTS, AND LOUVERS. ON THIS DRAWING IS THE TRUSS CARRIER CONNECTION TO POST: J"x4" GRK RSS STRUCTURAL SCREWS, SCREW PROPERTY OF SHIRK SHIRK POLE BUILDINGS LLC WILL NOT BE LIABLE FOR ANY FAILURES RESULTING POLE BUILDINGS LLC. VALUES; LATERAL DESIGN VALUE=333 LB, TENSILE STRENGTH=139,000 PSI, FROM THOSE MODIFICATIONS LISTED ABOVEOR FROM ANY OTHER MODIFICATIONS THIS NWOUCE MAY NOT , PULLOUT=2644 LBS, HEAD PULL THROUGH=825 LBS, MIN. BENDING ANGLE=35' �REPRooucm unmoor NOT APPROVED BY A CERTIFIED ENGINEER. PERMISSION.BUILDER AND A4.7 METAL SIDING AND ROOFING METAL SIDING AND ROOFING SHALL BE INSTALLED OMER ARE RESPONSIBLE TO VTRIFY ALL DIMENSIONS WITH #9 AL AND ER HERED COLOR MATCHING SCREWSXFA FASTENERS SHALL COMPLY WITH THE THE ROOFINGN&ESIIDING ���� of: New10//�e DRAWN BY: ATLRSCTION MFG'S REQUIREMENTS. METAL SIDING AND ROOFING SHALL BE WARRANTED `�� YD��i' REVIEW: #1 GRADE 80,000 PSI MIN. TENSILE STRENGTH CORRUGATED 28 GAUGE PAINTED ��Gj��• �jy •F REVISIONS: ABM STEEL PANELS GALVANIZED TO A MINIMUM OF G-100. METAL SIDING AND ROOFING SHALL BE TRIMMED WITH CORRECT FLASHINGS AT =C ¢ �• m: EXPOSED EDGES, ROOF ENDS, CORNERS, DOORS, WINDOWS AND RIDGES, EXCEPT; 's n ZD DATE: 2/15/21 BOTTOM EDGE OF STANDARD ROOFING MATERIALS. s m 2 SITE:WESNOFSKE ; DETAILS Job Truss Truss Type Qty Ply 21021521 B T30 COMMON 1 1 , Job Reference(optional) UFP,UFP 20/20 Run:8.410 s Jun 25 2020 Print:BA10 s Jun 25 2020 MTek Industries,Inc. Mon Feb 1516:10:05 2021 Page 1 ID:4CN MplCg E7rU7vsl4EhaQ2zks9Z-1 s 1 YogxbiyEovgpxh-W 7 h2BZ8p1 ZGkBvEk6k3czks9G X010-8 7-10.14 15.0-0 22-12 30.0-0 , 10 7-10.14 7-1-2 7-1-2 7-10-14 Salo.1:00.5 4.00 1z _ sxe s 4- 17 17 1 2 7 f0 9 8 4x4= 4x12Mr20H5= 4x0= 4x0= 10-3-4 19.8-12 30-0-0 _ 10-3.4 9-5-8 10-3.4 Plate Offsets(KY)- [5:0-3-0,0-3-81,[8:0-1-8,0-1-121,[10:0-1-8,0-1-121 LOADING(psf) SPACING- 4-M CSI. DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 30.0 5.0 Plate Grip DOL 1.15 TO 0.61 Vert(LL) -0.33 5-10 >999 240 MT20 197/144 (Roof Snow-30.0) Lumber DOL 1.15 - BC 0.80 Vert(CT) -0.51 8-10 >711 180 MT20HS 148/108 BCDL 5.0 Rep Stress Incr NO WB 0.57 Horz(CT) 0.16 7 n/a n/a BOLL 0.0 BCDL 5.0 Code IBC2018/TPI2014 Matrix-MS Weight:134 Ib FT=20% LUMBER- BRACING- TOP CHORD 2x6 SP 240OF 2.0E TOP CHORD 2-0-0 oc purlins(3-11-0 max.). BOT CHORD 2x4 SPF 2100F 1.8E BOT CHORD Rigid ceiling directly applied or 4-9-5 oc bracing. WEBS 2x4 SPF No.2 REACTIONS. (lb/size) 2=2492/0-8-8,7=2399/0-8-8 Max Horz 2=233(LC 12) Max Uplift2-1080(LC 8),7=4000(LC 9) FORCES. (ib)-Maximum Compression/Maximum Tension TOP CHORD 1-2.0/29,2-17=-5737/2892,3-17=-5614!2909,3-4=4928/2584,4-18=4783/2586,5-18=4758/2601,5-19=-4762/2619,6 19=4933/2604,6-20=-5605/2936, 7-20=5715/2920 BOT CHORD 2-10--2587/5326,9-10=-1611/3568.8-9=-1611/3568,7-8=-2617/5335 WEBS 3-10_1449/817,5-10--659/1697,5-8=-663/1703,6-8--1454/820 NOTES- 1)Wind:ASCE 7-16;Vult=130mph(3-second gust)Vasd=103mph;TCDL=3.Opsf;BCDL-3.Opsf;h-20ft;Cat.11;Exp C;Enclosed;MWFRS(envelope)gable end zone and C-C Extedor(2E)-0-7-13 to 3-4-3,Intedor(1)3-4-3 to 11-0-0,Exterior(2R)11-0-0 to 19-0-0,Intedor(1)19-0-0 to 26-0-0,Extedor(2E)26-0-0 to 30-D-0 zone;C-C for members and forces &MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL-1.60 2)TOLL:ASCE 7-16;Pf=30.0 psf(Lum DOL=1.15 Plate DOL-1.15);Is=1.0;Rough Cat C;Partially Exp.;Ce=1.0;Cs=1.00;Ct=120 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 30.0 psf on overhangs non-concurrent -with other live loads. 5)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf(or less)Is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load. 6)All plates are MT20 plates unless otherwise Indicated. 7)This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1080 Ib uplift at joint 2 and 1000 Ib uplift at joint 7. 9)This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSVTPI 1. 10)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable,or consult qualified building designer. Or- NE Y 11)Graphical pudin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10A CAP, LOAD CASE(S) Standard GJ r Ci I �O 701355 v S S10�P 02/15/2021