Loading...
HomeMy WebLinkAbout46389-Z SUffet,�p Town of Southold 7/17/2022 aO Gym S P.O.Box 1179 C= 53095 Main Rd y�,0� Laos Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43261 Date: 7/17/2022 THIS CERTIFIES that the building RESIDENTIAL ADDITION Location of Property: 4510 Rocky Point Rd.,East Marion SCTM#: 473889 Sec/Block/Lot: 21.-3-26.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/12/2021 pursuant to which Building Permit No. 46389 dated 6/9/2021 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions, including outdoor shower and deck addition with hot tub,to existing single-family dwelling as applied for. The certificate is issued to Gans,Allison&Wolfe,Erin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46389 12/21/2021 PLUMBERS CERTIFICATION DATED 6/9/2022 6 j-\Drykel Perg e o th ri e Signature �o�SUFFQtp.o. TOWN OF SOUTHOLD gay BUILDING DEPARTMENT N s ' TOWN CLERK'S OFFICE "oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46389 Date: 6/9/2021 Permission is hereby granted to: Gans, Allison 584 Pacific St#2 Brooklyn, NY 11217 To: construct outdoor shower and deck addition with hot tub to existing single-family dwelling as applied for. At premises located at: 4510 Rocky Point Rd., East Marion SCTM #473889 Sec/Block/Lot# 21.-3-26.1 Pursuant to application dated 5/12/2021 and approved by the Building Inspector. To expire on 12/9/2022. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $316.00 SWIMMING POOLS-ABOVE-GROUND WITH REQUIRED FENCING $250.00 CO-ADDITION TO DWELLING $50.00 Total: $616.00 uil1 spector OF SO(/l�,ol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Q sean.devlin(W-town.South old.ny.us Southold,NY 11971-0959 .�` • �� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Allison Gans Address: 4510 Rocky Point Rd City:East Marion st: NY zip: 11939 Building Permit* 46389 Section: 21 Block: 3 Lot: 26.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Northshore Electrical License No: 57212ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1 st Floor Deck X New X Renovation 2nd Floor Hot Tub X Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 50A Switches 2 4'LED Exit Fixtures Pump Other Equipment: 250GFI Disconnect, (23) Step Lights Notes: Rear Deck Lighting& Hot Tub Inspector Signature: Date: December 21, 2021 p 9 S.Devlin-Cert Electrical Compliance Form Town Hall Annex Telephone(631)765-1802 54375 Main Road � � Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 Q B D—ILDING DEPHRTt'ViENT TOWN OF SOUTHOLD ® JUIN 2 4 2022 IDJ BUILDING DEP7.- TOWN OF SOU7-HOLD LD CERTIFICATION l Date: 94 Building Permit No. Owner: _ eev'-t /l (Please print) Plumber: (Please p int) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. . agnature) Sworn to before me this day of C20_Q,� ,aV' FSP PEGQF ti �•PY PU•Rp NEW),C•'•• NotaPublic, 1 n y Cy Public, OLillty :J NIPE5039824 LK •• ��40nic`(P\AF +►��gq If SOGTyO� - - 1 TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 . IN SPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ]. FRAMING /STRAPPING [ FINALor, S"ut, wl Tt* 9 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ eARKS:E VIO TION [ ] PRE C/O [ ] RENTAL Rftl - DATE h tc2INSPECTOR SOF 50UTy * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND, [ INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL, �i'CIMJ?1 ` SQ or [ ] FIREPLACE & CHIMNEY [' ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] =FIRE RESISTANT PENETRATION [ ' ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ PRE C/O REMARKS: i u G��- . A� y iQ $06&y v O DATE INSPECTOR oF suaryolo l �( 0 L SOUTHOLD BUILDING DEPT. ' °`yrouxn,� 65-1802 1 PECTION [ ] FOUNDATION 1ST :' Yom[ ] ROUGH PLBG. [ ] FOUNDATION2ND [ ] INSULATIOWCAULKING [ ] FRAMING %STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: DATE INSPECTOR _ -- a SOGlyolo \ J 10 * # TOW9 OF SOUTHOLD BUILDING DEPT. co 765-1802 �2 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY,INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL.(FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: 'law It'j';l -- /6 DATE INSPECTOR SOF so '�V `� � vL✓ * # TOWN OF-SOUTHOLDBUILDING DEPT A( cou765-1802 - 1 NSPECTION = [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ' [ ]--"INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE`& CHIMNEY `[ ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION- ( ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION /[ ' PRE C/O REMARKS: DATE 1 INSPECTOR - FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) H -------------------------------- FOUNDATION(2ND) O L ROUGH FRAMING& tl7 PLUMBING C INSULATION.PER N.Y. STATE ENERGY CODE GS FINAL ADDITIONAL COMMENTS (� Nb , H H � C b H ����Serotx o 1 TOWN OF SOUTHOLD—BUILDING DEPARTMENT in Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtonmu..gov ra� Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: MAY 1 2 2021 Applications and forms must be filled out,in their entirety. Incomplete. applications will not be accepted...Where the:Applicant is not the owner,an Owner's Authorization'form(Paget)shall be'completed. Date: OWNER(S)OF PROPERTY:', Name: , ,� SCTM # 1000- '�, -- m wn C, . . .,. :.. _ w...._w,...• 1. Project Address: Phone#: _ Email: � r �v 2-4—Ata�_C CoW►.. _.. Mailing Address: CONTACT.PERSON: Name: Mailing Address: Phone#: !o j.' ©.�� Q pia � Email: MMLARt DESIGN;PROFESSIONAL`"INFORMATION: I _ Name: Mailing Address: Phone#: Email' CZ CONTRACTOR'I N ORM Name:Name: Mailing Address: Phone#: Email: •DESCRIPTION OF;PROPOSED•'CONSTRUCTION= <.,, ;.r. ❑New Structure ❑Addition ❑Alteratio��n// ❑Repair ❑Demolition Estimated Cost of Project: Other b e (C e4— G pv� Glp�ve $ l s d©b LWill the lot be re-graded? ❑Yes KNo Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: f2 e j!� �' 4--G Intended use of property: Zone or use district in which premises is situated: Are there any covenants and(restrictions with respect to this property? ❑Yes lkNO IF YES, PROVIDE A COPY. 11 Check Box After Pleading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.' Application Submitted By(grin name): btsi-?/ f '� ��Vj—/D S�Authorized Agent ❑Owner Signature of Applicant: s Date: STATE OF NEW YORK) SS: COUNTY OUNTY being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this VO%of q, �-M L9Q��- . Notary Public MARIE DYKAS LPub lic,ttate of New York PROPERTY' O�� NER AUTHORIZATIO lified In Suffolk County(Where the applicant is not the owner) sion Expiresoec.13,2024 residing at r—.; /a �GG� i9Ce�! aJ 11141(2 do hereby authorize t i/) 1-e— to apply on my behalf to the To�w'nI of Southold Building Department for approval as described herein. Owner's Signwature Date Print Owner's Name 2 �ogUFFO�,� IUMING DEPARTMENT-Electrical Inspector E C E � 1°rTOWN OF SOUTHOLD o HIP a nnex- 54375 Main Road - PO Box 1179 o DEC 2 20 ! outhold, New York 11971-0959 • y'�O! WILDING DEPTTelephone (631) 765-1802 - FAX (631) 765-9502 TOWN OF 90-southoldtownny.ciov- seando_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2 Z Z) Company Name: Nps S e_ e- cckC Electrician's Name: ;� License No.: 5-7 21 Z _ME- Elec. email: i JR- eMc+ ' o►S4rck i oryl Elec. Phone No: ( S j) Z35= 6 pZ -F-11 request an email copy of Certificate of Compliance Elec. Address.: Q24L kNJ 11-1? S JOB SITE INFORMATION (All Information Required) Name: S ` so Address: Cross Street: Phone No.: Bldg.Permit#: 1-1(o�)-16 O� email: Tax Map District: 1000 Section: 2 Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph F-13 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect[—]service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? 7Y N Additional Information: PAYMENT DUE WITH APPLICATION ( C" cm Dwyer, Tracey From: Dwyer,Tracey Sent: Friday, May 06, 2022 3:42 PM To: erinhwolfe@gmail.com' Subject: 4510 Rocky Point Rd. building dept The following items are required before co's can be issued: 46389-deck/hot tub -Plumbers Lead Solder Certificate -Pictures of Framing& Footings or a letter of certification from an architect or engineer for the framing&footings 47727-generator -schedule an electric inspection to get a certificate of compliance -schedule a final inspection with the building inspector 45917- pool -latch release handle on gate to pool must be poolside of the barrier. s From: Danny Peguero dtpeguero@yahoo.com Subject: J385.pdf Date: May 26, 2021 at 6:35:16 PM To: Cp pegucj18@gmail.com JUN - 4 2021 Dimensions TOP VIEW FRONTIBACK VIEW To5erance;t 0.5'(1.27 cm) £hal �,,. blas• • • � �� ` � .a..�..sa,>.�_ arra, S(p'' z i �` ;• LEFT SIDE VIEW w * "Af : srf- Tolerance-t 0..5(1.27 cm) . �. �aada'(SSTcril FRONT - ' Egtlmmlt BayJPtlmy Aocc ss jiala cit CLEARRAY.100bra @LUEMAYS. Wooplartsenta..4mmadda _ air 1`r:'srsiHi�xi GaY.ltds-ihipaa:ks t5 s+^'t Wr , 475.2 rn# 7MPORTAN71 Always measure each hot tub. . forlexact dimensions BEFORE designing its foundational support andlor decking. 915?jY�9L5tu,1#B°:l . - +- —at'Srzdasari�eBent�i _ - aa�fzi3ar - ?+�R%f#tcnl > Im.12artalnt panel Details NOTE-bver.fime the panel(s)rnay.liow, TOP VIEW this is consWred normal.The panels will straighten out when reinstalled into the t r mounting channel.Place one end of the Tolerant±0.W(1.27 cm) panel into the channel first then flatten 42;!& ltm+i the panel and insert the other end. From,the edge of fig- A@S pan I 1wr Ct I Bay J L::EquLlpment x$Nnsaiil � y—* ° O sl I r C J-300 Figure C Equipment Area lift GO.LI . 1 do e 1 Note:Equipment location(such as pumps,CLEARRAY system, drain, heat- er etc.)varies by model.. 1. Control Box 9. Control Panel 2. Power Supply Entrances) 10. CLEARRAYO(Ultraviolet)1Nater 3. 1-Speed Jets Pump Purification System 4. Heater 11: OptionalSmartTub"A System 5. Spa Drain Valve,. 12.: Bridge(Optional for SmartTub 6. -Pump Drain Plugs(s) System) 7.. 1-=Speed Jets Pump 13: CLEARRAYO PR03TECTTM 8. Circulation Pump Figure D Control Box Figure E Connections (J335�1385,J3.15 and J325 3-Wire 240 VAC 60-Hz Models). am b � 1 i � 1 1 O 1 _ ;' oo Re e�• d ck,j: 1. Main Terminal 1 0 a®.� ".2. Bonding Lug/Grounding Terminal ;fe3 TB1 1 & Power wires entr=66-.(electrical fitting and conduit must be installed) --------------------- . 17 4 J-300 1201240 Volt Convertible Models A spa connected to a 120 VAC electrical service must be located close enough to a grounded, grounding-type electrical outlet so that the included 10 feet(3m) power cord can be plugged directly into it. DO NOT USE AN EXTENSION CORD as this could cause damage to the spa's equipment due to insufficient voltage.The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit. 6.0 Power Requirements Jacuzzi spas are designed to provide optimum performance . and flexibility of use when connected to the maximum electrical service listed below. Minor circuit board modifications can be performed,to allow-your new spa to accept an electrical service other than the factory operation setting. Note: Refer to pages 57-59 for circuit board configuration details or contact your authorized Jacuzzi dealer._ 6.1_ 2-Pump 240V Power Requirements- North American J-335,J-345,J-355, J-365,J-375 and J-385 Models .0 240V/50A " 240V/60A' * Circuit Breaker(2-Pole): 40A 50A 60A Number:of Wires: 3 3 3 Frequency: 60 Hz 60 Hz 60 Hz Current Draw: 26A 37A 48A- In 8AIn 40A configuration,.the heater MdII not operate while either.jets .pump is running. +t+. In 50A configuration, the-heater will not.operate while both jets pumps are running. This is the factorysetdn In 60A configuration the heater will oaerate while both jets pumps are running. 13 WOLFE GANS RESV" 4'CE i 4510 P oint Road Ec v."1, New York marshall poetzel LANDSCAPE ARCHITECTURE 5175 Route 48 Mattituck,NY 11952 phone: (631) 209-2410 fax: (631)315-5000 t30'-4" email: mail@mplastudio.com BF28'BIG FOOT FOOTING' 6-2 T-7" 16-7"WIDE STEPS SURVEYOR: -SEE DETAIL 3 Kenneth Woychuk LS 5'-521"O.C. - 2x8 ACQ BASE N.P.O.YS. Li ensed Land Surveyor 153 HEADER Aquebogue, NY 11931 , :F 1 (12)2x12 ACQ STAIR STRINGERS @ 162'O.C. (TYP.)TO LAND ON 12"x3g"CONCRETE PAD (631) 298-1588 2x10 ACQ RIMPOURED TO FROST DEPTH JOIST(TYP.) /d PROPOSED 6"SLAB FOR (2)2x10 ACQ P.T.LEDGER SECURED W/.022 x 5 d FUTURE JACUZZI GIRDERS — SIMPSON SDWS SCREWS @ 1 O.C. — — — — — — — — — — — — — — — -FLASHING AS REQUIRED �— SIMPSON DTT2Z W/Z'GALV. a x 6 KEBONY CLEAR DECKING THREADED ROD W/NUTS+WASHERS N + 2 x 10 DECK GIRDER LUS210 JOIST HANGER 1 5'71" U O OF W O AT EACH DECK JOIST 6'-02"y 4 V p io p Q 2x10 ACQ RIM JOIST LU O-C. O O w m w O.C. _ � (NP) riiv U w it U)Z EXISTING BILCO zo o F_0 0 0= DOOR EXISTING HOUSE FOUNDATION N O w w EXISTING 6x6 P.T.POST W.PC6X POST CAP+ABU66 POST BASE o 2x8 ACQ BASE HEADER (4)2x12 ACQ STAIR STRINGERS @ 18"O.C.(TYP.)TO LAND ON 2x10 ACQ LEDGER BOARD TO BE 4'HT.PARTITION WALL BF28'BIG FOOT FOOTING' SITE DATA: 12"x63"CONCRETE PAD POURED TO FROST DEPTH AC FASTENED TO BUILDING WITH(2)z'LAG SEE DETAIL 3 FOR SCREWS @ 16"O.C.WITH COMPOSITE SPACERS BETWEEN LEDGER+HOUSE SCTM# 1000-21-3-26.1 Lot Area: 98,725.07 SF (or 2.27 acres) 2 TYPICAL DECK FRAMING DETAIL Detail Not to Scale NOTES: 1. Existing conditions based on survey prepared by Kenneth Woychuk Land EXISTING RESIDENCE Surveying dated 09.25.2020. 2. This drawing is for the purpose of obtaining permits only. NOT FOR CONSTRUCTION. 3. Unauthorized alteration of this plan is a violation of NYS Education Law. POST-SEE DETAIL 2 REVISIONS DATE DESCRIPTION SIMPSON CPT66Z POST BASE (2)2'ANCHOR BOLTS ADHESIVELY EMBEDED 5"W/ ) SIMPSON SET XP EPDXY 12"DIA.SONOTUBE ® (3)#5 DOWELS @ 8"O.C.W/HOOK 1 BF28'BIG FOOT FOOTING' s e a 1 EXISTING N CA'�F G3PDetoil 8'BIG FOOT FOOTING' z"�'.;' ,� — n1 DECK PLAN Not to scale Plan SCALE:1/4"=1'-0" 0` 027A O OF NENy TITLE: DECK SITE PLAN DECK CONSTRUCTION NOTES: - DECK FRAMING LUMBER (POSTS, BEAMS, JOISTS, LEDGERS, BLOCKING, ETC.)SHALL BE SOUTHERN PINE, GRADE#2 OR BETTER AND SHALL BE PRESSURE TREATED ACQ. -ALL JOISTS TO BE SUPPORTED WITH HANGERS AND ANCHORS, AND EACH JOIST SHALL ALSO BE ANCHORED TO GIRDER(S). �^ 5919 -GIRDERS FOR DECK JOISTS TO BE BOLTED TO EACH POST WITH WASHERS AND NUTS. 4D - POSTS SUPPORTING GIRDERS SHALL BE ANCHORED TO A 12" DIAMETER CONCRETE PIER WITH SIMPSON CPT66Z POST BASE SECURED WITH (2) '/2"X 8" BOLTS WITH WASHERS & NUTS. -CONCRETE FOOTING TO BE A MINIMUM OF 36" BELOW GRADE,AND CONCRETE PIERS ON FOOTING SHALL BE A MINIMUM OF 6" ABOVE GRADE. 0 2 4 -ALL HARDWARE AND FASTENERS (JOIST HANGERS, POST ANCHORS, MECHANICAL FASTENERS, NAILS,SCREWS, BOLTS,ETC.) SHALL BE GALVANIZED WITH G-185 COATING OR BE STAINLESS STEEL. -ALL DECKING MATERIAL SHALL BE 5/4 CLEAR KEBONY DECK BOARDS ATTACHED TO EACH JOIST WITH A MINIMUM OF (2) RING SHANK 8D NAILS OR 2-1/2"SCREWS. - INSTALL 2X10 ACQ BLOCKING BETWEEN JOISTS AT MID-SPAN,AND ADDITIONALLY AT N-0" OC ALONG THE LENGTH OF THE RIM JOIST. - INSTALL A STRIP OF METAL STRAP TIE SWAY BRACING DIAGONALLY ACROSS THE TOP OF DECK FRAMING BEFORE INSTALLING THE DECK BOARDS. APA 2 9 2021 Scalel/4"=1'-0" -INSTALL LATERAL LOAD CONNECTION DEVICES, METAL HOLD DOWN STRAPPING AND HURRICANE CLIPS TO MEET CURRENT BUILDING CODES. DRAWN BY: - INSTALL GUARD RAILS AND HANDRAILS TO MEET CODE AND ADD ADDITIONAL BRACING FOR STIFFNESS. N.COLLINS CHECKED BY: S P 1 J.PAETZEL,RLA DATE:2021.03.30 REVISED: SHEET 1 OF 1 I �6 s WOLFE GANS _PROPOSED- _, aPPR VEDAS NO D RESIDENCE DECK - DATE: B.P.# 4510 Rocky Point Road FEE: �� BY: East Marion, New York PROPOSED PROPOSED I NOTIFY BUILDING DEPARTMENT AT PATIO 765-1802 8 AM TO 4 PM FOR THE SWIMMING POOL (NP) FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED PROPOSED 4'H.NYS POOL CODE FOR POURED CONCRETE COMPLIANT DOUBLE GATE+FENCE I 2. ROUGH - FRAMING & PLUMBING G 3. INSULATION I' I 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOP C.Q. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW �— YORK STATE. NOT RESPONSIBLE FOR I � DESIGN OR CONSTRUCTION ER marshal) poetel I � I EXISTING STOOP i it I i ROBS. I TO REMAIN I LANDSCAPE ARCHITECTURE EXISTING EMAIN EXISTING TOREMA° J COMPLY WITH ALL CODES OF m NEW YORK STATE & TOWN CODES 5175 Route 48 SHED TO REMAIN � � 1, � I' Mattituck,NY 11952 EXISTING AS REQUIRED AND CONDITIONS OF I � STEPS TO REMAIN I PROPOSED OUTDOOR SHOWER �'�/ �, ' �rF r 7Re phone: (631) 209-2410 -SEE DETAILS 1+2 I I..L fax: (631)315-5000 = PROPOSED 4'H.NYS POOL CODE 1,e © I LL.I w' r I BOARD email: mail@mplastudio.com a COMPLIANT GATE+FENCE _ � ' USTEES Ly EXISTING RESIDENCE i N y c nuc SURVEYOR: EXISTING PROPANE---moo Kenneth Woychuk LS TANK CAP N.Y.S. Licensed Land Surveyor O P.O. Box 153 I I J , , I Aquebogue, NY 11931 EXISTING STOOP �I OCCUPANCY R (631) 298-1588 PROPOSED PROPOSED 4 TO REMAIN 0 I I I 'H.NYS POOL CODE DRIVEWAY COMPLIANT GATE+FENCE USE IS UNLAWFUL Q ! ' EXISTING DRIVEWAY WITHOUT CERTIFICATE TO BE REMOVED 3 I0 I OF OCCUPANCY co Ico to j I j RETAIN STORM WATER RUNOFF PURSUANT TO OF THE TOWN CODE�ER 236 I��ir H��`�EL ENCLOSE POOL TO CODE COMPLETION BEFORE"WATER" I � W I i ELECTRICAL i INSPECTION REQUIRED co ZI I I SITE DATA: 1 SCTM# 1000-21-3-26.1 EXISTING GATE Lot Area: 98,725.07 SF (or 2.27 acres) -+� — — 385.29' N 07-os 20 w — — — — — — — — — — — — — — — — — — - 1 EXISTING UTILITY POLE(TYP.) EXISTING DRAIN NOTES: ROCKY POINT ROAD 1. Existing conditions based on survey prepared by Kenneth Woychuk Land EDGE OF PAVEMENT(TYP.) Surveying dated 09.25.2020. 2. This drawing is for the purpose of obtaining permits only. NOT FOR CONSTRUCTION. 3. Unauthorized alteration of this plan is a violation of NYS Education Law. PROPOSED DECK STEPS REVISIONS DATE DESCRIPTION 2x4 PRESSURE TREATED INTERNAL DOOR FRAME PAINTED BLACK EDGE OF EXISTING RESIDENCE SELF CLOSING STAINLESS 1 4 x 6 KEBONY CLEAR CAP L STEEL BUTT HINGES 2:1 3'-51"� 2'4" S e a I T r 4 x 6 KEBONY CLEAR BOARD `-,F.% SC SECURED WITH STAINLESS ��`;�..•��. _.�� �, . 4x4 PRESSURE TREATED POST 4CLOSED POSITION X STEEL TRIM SCREWS(TYP.)PAINTED BLACK(TYP.) " '' /•'- > LATCH TBD V-6' WRAP INTERNAL PRESSURE TREATED FRAME WITH NON WOVEN BLACK 4 x 6 KEBONY CLEAR CLADDING WRAP PRESSURE TREATED FILTER FABRIC ON WALLS+GATE SECURED TO FRAME W/ o STAINLESS STEEL TRIM SCREWS BENCH FRAME IN KEBONY f,� �_ rf CLEAR DECKING INTERNAL PRESSURE TREATED BENCH FRAME TO BE WRAPPED IN 4 x 6 KEBONY CLEAR DECKING WRAP INTERNAL PRESSURE TREATED PROVIDE VENTILATION @ BOTTOM FRAME WITH NON WOVEN BLACK EXISTING RESIDENCE OF FRAMING PLATE FILTER FABRIC ON WALLS+GATE � TITLE: C? x WRAP 4x 6 KEBONY CLEAR AROUND °0 PRESSURE TREATED POST w/MITERED .fir CORNERS(TYP.) 2x4 NAILER INSIDE SHOWER FIXTURE TBD SIDE FACING STREET TO HAVE I OUTDOOR FRAME PAINTED BLACK CLADDING DOWN TO FINISHED GRADE 4x4 PRESSURE TREATED POST- ° - 1 j J a `- � a - i � I i' SHOWER PAINT BLACK PRIOR TO - SITE PLAN INSTALLATION(SEE PLAN VIEW - FOR LOCATIONS) PROPOSED FENCE TBD ° -I I ° - PREPARED !_' CONCRETE SURROUNDING POST aD SUBGRADE _ !' -11 4'CRUSHED STONE BASE O 10 20 THIS SIDE TO HAVE CLADDING DOWN -0 _ TO FINISHED GRADE TO ACT AS r ' `" 1 PORTION OF POOL CODE V/ COMPLIANT ENCLOSURE _ ,I r Scale 1"=20'—O" MAY 1 2 2021 DRAWN BY: N.COLLINS SP OUTDOOR SHOWER PLAN OUTDOOR SHOWER SECTION t 0.- , -.14 . �,��,�. CHECKED BY: S.PAETZEL,RLA (D= �r� ' ' DATE:2021.05.10 Plan 1/Z, 1'-0" Section 1/2"= 1'-0" REVISED: SHEET 1 OF 1 WOLFE GANS RESIDENCE 4510 Rocky Point Road East Marion, New York marshall poetzel LANDSCAPE ARCHITECTURE 5175 Route 48 Mattituck,NY 11952 phone: (631) 209-2410 fax: (631)315-5000 t30'-4" email: mail@mplastudio.com BF28'BIG FOOT FOOTING' —6'-2"� 7-7 16'-7"WIDE STEPS -SEE DETAIL 3 SURVEYOR: Kenneth Woychuk LS 5'-5�"O.C.__ P.OSBoIx 153ed Land Surveyor 2 2x8 ACQ BASE HEADER 1 (12)2x12 ACQ STAIR STRINGERS @ 162"O.C. Aquebogue, NY 11931 (TYP.)TO LAND ON 12"x39"CONCRETE PAD (631) 298-1588 2x10 ACQ RIM / POURED TO FROST DEPTH P.T.LEDGER SECURED W/.022 x 5 JOIST(TYP.) PROPOSED 6"SLAB FOR (2)2x10 ACQ SIMPSON SOWS SCREWS @ 16"O.C. U p FUTURE JACUZZI — — — — —GIRDERS _ — — — — -FLASHING AS REQUIRED 0 t I SIMPSON DTT2Z W/2'GALV. a x 6 KEBONY CLEAR DECKING THREADED ROD W/NUTS+WASHERS I N + F- 2 x 10 DECK GIRDER x U V LUS210 JOIST HANGER 1 5,71„ U O Op-W O AT EACH DECK JOIST d t"!: I I 6'-02° O.C. O �LU �w0i� w O.C. _ a Z m F c7 2x10 ACQ RIM JOIST (TYP-) r>iv U @ w U Z EXISTING BILCO FD C)Cnn 0 DOOR EXISTING HOUSE FOUNDATION N O w EXISTING 6x6 P.T.POST W.PC6X POST CAP+ABU66 POST BASE o 2x8 ACQ BASE HEADER (4)2x12 ACQ STAIR STRINGERS @ 18"O.C.(TYP.)TO LAND ON 2x10 ACQ LEDGER BOARD TO BE 4'HT.PARTITION WALL BF28'BIG FOOT FOOTING' SITE DATA: 12"x63"CONCRETE PAD POURED TO FROST DEPTH � FASTENED TO BUILDING WITH(2)2'LAG AC SEE DETAIL 3 FOR SCREWS @ 16"O.C.WITH COMPOSITE SPACERS BETWEEN LEDGER+HOUSE SCTM# 1000-21-3-26.1 Lot Area: 98,725.07 SF (or 2.27 acres) 2 TYPICAL DECK FRAMING DETAIL Detail Not to Scale NOTES: 1. Existing conditions based on survey prepared by Kenneth Woychuk Land EXISTING RESIDENCE Surveying dated 09.25.2020. 2. This drawing is for the purpose of obtaining permits only. NOT FOR CONSTRUCTION. 3. Unauthorized alteration of this plan is a violation of NYS Education Law. POST-SEE DETAIL 2 REVISIONS DATE DESCRIPTION SIMPSON CPT66Z POST BASE (2)2"ANCHOR BOLTS ADHESIVELY EMBEDED 5"W/ SIMPSON SET XP EPDXY 12"DIA.SONOTUBE ® (3)#5 DOWELS @ 8"O.C.W/HOOK BF28'BIG FOOT FOOTING' S e a 1 I _._. EXISTING 1. 09eta! 8' IG FOOT FOOTING' Y ( I c C�D�EPLAN Not to Scale ' CK PlanSCALE:1/4"=1'-0" rr TITLE: DECK SITE PLAN DECK CONSTRUCTION NOTES: - DECK FRAMING LUMBER (POSTS, BEAMS, JOISTS, LEDGERS, BLOCKING, ETC.)SHALL BE SOUTHERN PINE, GRADE#2 OR BETTER AND SHALL BE PRESSURE TREATED ACQ. -ALL JOISTS TO BE SUPPORTED WITH HANGERS AND ANCHORS, AND EACH JOIST SHALL ALSO BE ANCHORED TO GIRDER(S). -GIRDERS FOR DECK JOISTS TO BE BOLTED TO EACH POST WITH WASHERS AND NUTS. - POSTS SUPPORTING GIRDERS SHALL BE ANCHORED TO A 12" DIAMETER CONCRETE PIER WITH SIMPSON CPT66Z POST BASE SECURED WITH (2) '/2"X 8" BOLTS WITH WASHERS &NUTS. -CONCRETE FOOTING TO BE A MINIMUM OF 36" BELOW GRADE,AND CONCRETE PIERS ON FOOTING SHALL BE A MINIMUM OF 6" ABOVE GRADE. 0 2 4 -ALL HARDWARE AND FASTENERS (JOIST HANGERS, POST ANCHORS, MECHANICAL FASTENERS, NAILS,SCREWS, BOLTS, ETC.) SHALL BE GALVANIZED WITH G-185 COATING OR BE STAINLESS STEEL. -ALL DECKING MATERIAL SHALL BE 5/4 CLEAR KEBONY DECK BOARDS ATTACHED TO EACH JOIST WITH A MINIMUM OF (2) RING SHANK 8D NAILS OR 2-1/2' SCREWS. - ' - - INSTALL 2X10 ACQ BLOCKING BETWEEN JOISTS AT MID-SPAN,AND ADDITIONALLY AT 4'-0" OC ALONG THE LENGTH OF THE RIM JOIST. - INSTALL A STRIP OF METAL STRAP TIE SWAY BRACING DIAGONALLY ACROSS THE TOP OF DECK FRAMING BEFORE INSTALLING THE DECK BOARDS. JUN ?OZ1 Scale /4"=j'_0" - INSTALL LATERAL LOAD CONNECTION DEVICES, METAL HOLD DOWN STRAPPING AND HURRICANE CLIPS TO MEET CURRENT BUILDING CODES. DRAWN BY: - INSTALL GUARD RAILS AND HANDRAILS TO MEET CODE AND ADD ADDITIONAL BRACING FOR STIFFNESS. N.COLLINS ES P 1 CHECKED BY: J.PAETZEL,RLA DATE:2021.05.27 REVISED: SHEET 1 OF 1