HomeMy WebLinkAbout48266-Z ` TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 48266 Date: 9/7/2022
Permission is hereby granted to:
Goggins, William
PO BOX 65
Mattituck, NY 11952
To: legalize "as built" windows to existing cottage as applied for.
At premises located at:
2000 Jackson St., New Suffolk
SCTM # 473889
Sec/Block/Lot# 117.-10-17
Pursuant to application dated 7/27/2022 and approved by the Building Inspector.
To expire on 3/8/2024.
Fees:
ELECTRIC $170.00
AS BUILT-ACCESSORY $200.00
CERTIFICATE OF OCCUPANCY $50.00
Total: $420.00
4—
Building Inspector
ria TOWN OF SOUTHOLD—BUILDING DEPARTMENT
9 Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 lett')S://kvvviv.soutlioldtowllny.gov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only n ry
ilr
PERMIT NO. Building Inspectors
Jul
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,ant4:�:
Owner's Authorization form(Page 2)shall be completed.
Date:.
OWNER(S)OF PROPERTY:
Name: Goggins, William and Donna SCTM# l000- 117-107-17
Project Address: 2000 Jackson Street, New Suffolk
Phone#: 631 .905.4494 Email:
Mailing Address: PO Box 65, Mattituck, New York. 11952
CONTACT PERSON:
Name: William Goggins
Mailing Address:
Phone#:
Tim
DESIGN PROFESSIONAL INFORMATION:
Name: Nygel,Williamson
Mailing Address:
Phone#: TE
CONTRACTOR INFORMATION:
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
D Other as built window replacements in cottage; $
Will the lot be re-graded? ❑Yes iRNo Will excess fill be removed from premises? ❑Yes igNo
* fourteen (14) replacement double hung windows made by Weathershield. Specifications
attached hereto. Electric Panel Cottage. Electric Pane' House. A ,
1
PROPERTY INFORMATION
Existing use of property: Residential Intended use of property: Residential
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? ❑Yes i@ No IF YES, PROVIDE A COPY.
❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print a ❑Authorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF SUFFOLK
William Goggins
being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
OWNER
(S)he is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of 20
Notary
L7�I
7No.
�i.NOTARY PUOF NEW YO 'KRegistrA6052585
QualCounPROP RT N R UTA Ilfli TI N ty
Commissionruary 13,
(Where the applicant is not the owner)
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
" I DING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
12
ow I Annex - 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
�7 9,6, yon Tdlephone (631) 765-1802 - FAX (631) 765-9502
ro err southoldtownn ov — sea nd so utholdtown ny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name:
Electrician's Name:
License No.: Elec. email:
Elec. Phone No [:]I request an email copy of Certificate of Compliance
Elec. Address.:.
JOB SITE INFORMATION (All Information Required)
Name: Goggins, William and Donna
Address: 2000 Jackson Street, New Suffolk
Cross Street: Fourth Street
Phone No.: 631.905.4493
Bldg.Permit#: email: gogginslaw@gmail.com
Tax Map District: 1000 Section: 117 Block: 10 Lot: 17
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Panel in basement of Cottage
Square Footage:
Circle All That Apply:
Is job ready for inspection?: R YES E] NO F�Rough In Final
Do you need a Temp Certificate?: YES r---' NO Issued On
Temp Information: (All information required)
Service Size 1:11 Ph 03 Ph Size: A # Meters Old Meter#
❑New Service[—]Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground[_—]Overhead
Underground Laterals 1 M2 H Frame Pole Work done on Service? Y N
Additional Information: Pre-CO Inspection determined panels need electrical inspection
PAYMENT DUE WITH APPLICATION
911vla�
*7 1A-X, A6Y'_�%s�f
SECTION 08 52 13.03 �g�6
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
1660- //7. --10 -17 _
MANUFACTURER �� Ft C
Weather Shield Mfg., Inc. .
One Weather Shield Plaza " JUL 2 7 2,02
P.O. Box 309
Medford, WI 54451-0309 BUILDING DEPT
Phone: 1-800-538-8836 -T0VJN OF:,oti T�a<
Fax: 1-800-390-1225
Web site: www.weathershield.com
E-mail: archservices(a�weathershield.com
CSI PRODUCT SPECIFICATION
Specifier note: This CSI product specification is written using the Construction Specifications Institute
(CSI) Manual of Practice (Fifth Edition), including MasterFormatTM, SectionFormatTm and PageFormatTM.
Edit all sections to suit project requirements.
Specifier note: Information contained in this CSI product specification is accurate as of December 2021.
Due to ongoing product changes, this information is subject to change. Consult manufacturer for
complete product details.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Aluminum Clad Exterior/Wood Interior Double-Hung Windows with Hardware.
B. Glazing.
C. Accessories.
1.2 RELATED SECTIONS
A. Section 01 33 00 -Submittal Procedures.
B. Section 01 65 00- Product Delivery Requirements.
C. Section 01 66 00-Product Storage and Handling Requirements.
D. Section 06 10 00 - Rough Carpentry.
E. Section 06 20 00 - Finish Carpentry.
F. Section 07 90 00-Joint Protection.
G. Section 08 80 00 -Glazing.
H. Section 09 90 00-Painting and Coating.
1.3 REFERENCES
A. American Society for Testing and Materials (ASTM):
1. ASTM C1036-Standard Specification for Flat Glass.
2. ASTM C1048 -Standard Specification for Heat-Treated Flat Glass—Kind HS, Kind FT
Coated and Uncoated Glass.
3. ASTM D3656—Standard Specification for Insect Screening and Louver Cloth Woven From
Vinyl-Coated Glass Yarns.
4. ASTM E283- Standard Test Method for Determining Rate of Air Leakage Through Exterior
Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the
Specimen.
5. ASTM E330-Standard Test Method for Structural Performance of Exterior Windows,
Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.
Weather Shield Windows & Doors Page 1 of 7 12/21
SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
6. ASTM E547-Standard Test Method for Water Penetration of Exterior Windows, Skylights,
Doors and Curtain Walls by Cyclic Static Air Pressure Difference.
7. ASTM E2190 - Standard Specification for Insulating Glass Unit Performance and
Evaluation.
8. , ASTM F588 - Standard Test Methods for Measuring the Forced Entry Resistance of
Window Assemblies, Excluding Glazing Impact.
B. American Architectural Manufacturers Association/Window and Door Manufacturers
Association/Canadian Standards Association (AAMA/WDMA/CSA):
1. AAMA/WDMA/CSA 101/I.S.2/A440-11/NAFS—North American Fenestration
Standard/Specification for Windows, Doors and Skylights.
C. American Architectural Manufacturers Association/Window and Door Manufacturers
Association/Canadian Standards Association (AAMA/WDMA/CSA):
1. AAMA/WDMA/CSA 101/I.S.2/A440-08/ NAFS—North American Fenestration
Standard/Specification for Windows, Doors and Skylights.
D. Window and Door Manufacturers Association (WDMA):
1. WDMA I.S.2—Hallmark Certification Program.
2. WDMA 4-05 - Industry Standard for Water Repellent Preservative Non-Pressure Treatment
for Millwork.
E. American Architectural Manufacturers Association (AAMA):
1. AAMA 450—Voluntary Performance Rating Method for Mulled Fenestration Assemblies.
2. AAMA 611 —Voluntary Specification for Anodized Architectural Aluminum.
3. AAMA 2604-Voluntary Specification, Performance Requirements and Test Procedures for
High.Performance Organic Coatings on Aluminum Extrusions and Panels.
4. AAMA 2605—Voluntary Specification, Performance Requirements and Test Procedures for
Superior Performing Organic Coatings on Aluminum Extrusions and Panels..
F. National Fenestration Rating Council (NFRC):
1. NFRC 102 - Procedure for Measuring the Steady-State Thermal Transmittance of
Fenestration Systems.
2. NFRC 200 - Procedure for Determining Fenestration Product Solar Heat Gain Coefficient
and Visible Transmittance at Normal Incidence.
3. NFRC 500 - Procedure for Determining Fenestration Product Condensation Resistance
Values.
4. ENERGY STAR®Compliant Models available.
G. Insulating Glass Certification Council (IGCC).
H. Safety glass tested in accordance with ANSI Z97.1.
I. Screen Manufacturers Association (SMA):
1. SMA-1201-2013—Specifications for Insect Screens for Windows, Sliding Doors and
Swinging Doors.
J. Forest Stewardship Council®(FSC°):
1. FSC-STD-40-003 V1-0—Standard for Multi-site Certification of Chain of Custody
Operations.
2. FSC-STD-40-004 V2-1 —Standard for Chain of Custody Certification.
1.4 PERFORMANCE REQUIREMENTS
Weather Shield Windows &Doors Page 2 of 7 12/21
SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
Specifier note: Product performance is dependent upon size and style. For further information see
www.weathershield.com or contact your Weather Shield territory manager.
A. Design and performance requirements:
1. Double-hung tilt windows shall be Hallmark certified in compliance with [AAMA/WDMA/CSA
101/I.S.2/A440-1 1] [ANSI/AAMA/NWWDA 101/I.S.2/A440-08]:
[LC-PG50-H]
[CW-PG35-H]
2. Vertical mull, mulled and applied rating: LC50.
3. Air infiltration shall not exceed 0.30 cfm/ft2 (1.5 L/s•m2)when tested at 1.57 psf[75 Pa]
according to ASTM E283.
4. No water penetration when tested at the following pressure according to ASTM E547:
[LC-PG50-H —7.50 psf(360 Pa)]
[CW-PG35-H —5.25 psf(251 Pa)]
5. Double-hung tilt windows must withstand the following positive/negative structural test
pressure without damage when tested according to ASTM E330:
[LC-PG50-H —+/-75.0 psf(3600 Pa)]
[CW-PG35-H - +/-52.5 psf(2510 Pa)]
6. Double-hung tilt windows must pass a forced entry resistance test of at least Grade 10 to
meet requirements set forth in ASTM F588.
1.5 SUBMITTAL PROCEDURES
A. Shop drawings: submit shop drawings according to Section 01 33 23—Shop Drawings,
Product Data and Samples.
B. Product data: submit manufacturer's product catalog data and installation guides.
C. Samples: submit samples including the following:
1. Corner cutaway: submit corner cutaway, including glazing system, quality of construction
and specified exterior/interior finishes.
2. Exterior: submit color samples of exterior color finishes.
3. Hardware: submit samples indicating typical hardware finishes.
D. Quality control reporting: submit manufacturer's test results reported by independent laboratory
indicating compliance with specified performance and design requirements, as listed in 1.4
Performance Requirements, according to Section 01 33 26—Source Quality Control Reporting.
1.6 QUALITY ASSURANCE
A. Single source responsibility: except for hardware mechanisms, weather strip, insulated glass
and aluminum extrusions, the window manufacturer is responsible for fabrication of all
components and materials including treatment of wood with acceptable wood preservatives,
millwork of sash and frame members and manufacture of all sash and frames.
B. Regulatory requirements:
1. Emergency escape and rescue: comply with requirements for sleeping units o
[IBC International Building Code] [IRC International Residential Code]
1.7 PRODUCT DELIVERY REQUIREMENTS
A. Comply with the product delivery requirements specified in Section 01 65 00 - Product Delivery
Requirements.
Weather Shield Windows & Doors Page 3 of 7 12/21
SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
1.8 PRODUCT STORAGE AND HANDLING REQUIREMENTS
A. Comply with the requirements for storage and handling of products as specified in
Section 01 66 00—Product Storage and Handling Requirements.
B. Store units in a dry location, off the ground, under cover, protected from weather and
construction activities.
1.9 WARRANTIES
A. Workmanship and materials: 20-year limited warranty.
B. Wood rot: 30-year warranty.
C. Insulating glass: 20-year warranty.
PART 2 PRODUCTS
2.1 MANUFACTURED UNITS
A. Weather Shield Premium SeriesTm 8120 Aluminum Clad Exterior/Wood Interior Double-Hung
Windows as manufactured by Weather Shield Mfg., Inc. of Medford, Wisconsin.
2.2 ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOW MATERIALS
A. Frame:
1. Exterior frame members milled from pine, kiln dried to a moisture content of 6-12% at the
time of fabrication and treated with a water-repellent preservative. Frame corners shall be
square cut, rabbeted at head, dadoed at sill, chemically and mechanically fastened.
2. Frame is clad with .050" [1.3mm] extruded aluminum, with an integral extruded nailing fin.
Top corners shall be mitered, include internal aluminum corner keys, and be chemically
and mechanically fastened. Sill shall include a vinyl thermal break sill riser that interlocks
into extruded aluminum sill cover.
3. Interior frame materials to be milled from [pine (standard)] [oak] [cherry] [maple]
[mahogany] [vertical grain fir][mixed grain fir] [white oak] [character alder] [FSC®-certified
FSC-C095408 (specify species)], kiln dried to a moisture content of 6-12% at the time of
fabrication and treated with a water-repellent preservative.
4. Frame shall have standard 5-3/16" [148mm] overall jamb depth with 4-9/16" [116mm] from
backside of nailing fin to interior of window.
5. Options:
a. [Frame provided with [factory applied (standard)] [shipped loose]jamb extensions for
wall depth]. Jamb extensions match interior frame finish.
b. [Interior saw kerf].
B. Sash:
1. Sash shall be composed of two materials, an extruded aluminum exterior of.050" [1.3mm]
thickness, butt joined at corners, chemically and mechanically bonded to the interior wood
substrate. Interior sash corners shall be mortised, tenoned and mechanically fastened.
2. Interior sash materials to be milled from [pine (standard)] [oak] [cherry] [maple] [mahogany]
[vertical grain fir] [mixed grain fir] [white oak] [character alder] [FSC®-certified FSC-
0095408 (specify species)], kiln dried to a moisture content of 6-12% at the time of
fabrication and treated with a water-repellent preservative.
3. Bottom rail shall be 3-1/2" [89mm] tall. Top sash top rail shall be 2-3/4" [70mm]tall; stiles
for both sash shall be 1-1/2" [38mm]wide.
Weather Shield Windows &Doors Page 4 of 7 12/21
SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
4. Both top and bottom sash shall interlock together using extruded aluminum interlocking
cladding at the meeting rail.
5. Top and bottom sash must tilt in from the inside for cleaning purposes without removal of
screens (standard). Top sash stationary with non-tilting bottom sash with extended side
sash stops when Class 5 balances are required.
C. Finish:
1. Exterior aluminum finish: silicone-modified polyester topcoat over high performance primer
meets AAMA 2604 requirements. Colors: [to be selected from one of the manufactures
standard colors] [custom color as selected by the Architect].
2. Exterior aluminum finish: fluoropolymer-modified acrylic topcoat over fluoropolymer primer
meets AAMA 2605 requirements. Colors: [to be selected from one of the manufactures
standard colors] [custom color as selected by the Architect].
3. Exterior anodized aluminum finish: electrolytic two-step coloring method meets AAMA 611
Class I requirements. Finishes: to be selected from one of the manufactures standard
finishes.
4. Interior finish: [clear treated wood (standard)] [primed [white] [black]] [prefinished [white]
[black] latex] [polyurethane painted with color selected from one of the manufactures
standard colors] [stained and sealed with color selected from one of the manufactures
standard colors].
Specifier note: Copy this section for as many glass types that are required. Product thermal
performance is dependent upon glass type. For further information see www.weathershield.com or
contact your Weather Shield territory manager.
D. Glazing: select quality complying with ASTM C1036. Insulating glass IGCC certified to
performance level CBA when tested in accordance with ASTM E2190.
1. Glass type:
a. Insulated glass consisting of two lites of clear [annealed (standard)] [tempered] glass.
2. Thermal performance:
U-value-total, NFRC 100
Solar Heat Gain Coefficient (SHGC), NFRC 200
Visible Light Transmittance (VLT), NFRC 200 r
Condensation Resistance Rating (CRR), NFRC 500
3. Insulated glass airspace:
a. Insulated glass shall be sealed with a [black (standard)] [silver] spacer system to meet
thermal performance.
4. Glass shall be silicone glazed at exterior to allow reglazing from the interior with [colonial
(standard)] [putty] [square] glazing bead. Back side of glazing bead to be finished black.
E. Hardware:
1. Sash counter-balance system to be comprised of an inverted, constant-force, stainless
steel coil system (standard)that is contained in pivot, locking shoe. Balance system must
meet AAMA 902-07 Class 3 requirements. Jamb liner shall be [wood-wrapped] [tan] [white]
vinyl extruded by window manufacturer.
2. Class 5 spiral rod balances with extended side sash stops and non-tilt bottom sash for
heavier sash applications. Jamb liner shall be [wood-wrapped] [tan] [white] vinyl extruded
by window manufacturer with exterior aluminum jamb liner cover.
3. Locking mechanism is concealed tilt-release latch hardware with nylon tilt pins. Upper sash
has two tan zinc die-cast flush-mounted tilt latches factory applied.
4. Sash locks [contemporary] [historical] shall be zinc die cast, recessed mounted at bottom
sash check rail and factory applied. Sash lock/keeper finishes: [tan (standard)] [white]
[rustic bronze] [brushed nickel] [bright brass] [black].
5. Options: Sash lifts [no applied lift hardware (standard)] [field-applied [contemporary]
[historic] sash lift] [Window Opening Control Device (WOCD)].
Weather Shield Windows & Doors Page 5 of 7 12/21
SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
F. Weather stripping:
1. Flexible vinyl weather strip shall have contact to the frame around each sash.
G. Screens:
1. [Full] [Half] screen consisting of.019" [0.5mm] thick formed aluminum frame with baked-on
acrylic coating with injection molded vinyl corner keys, [20x20 high-visibility vinyl-coated
charcoal fiberglass (standard)] [18x16 black aluminum non-glare] mesh.
2. Frame finish: matches exterior frame/sash.
Optignalaccessores PEdjt as required
H. Interior removable grilles:
1. Full perimeter 7/8" (23mm) colonial profile wood grilles with no exposed fastening devices
[factory applied (standard)] [shipped loose].
2. Pattern: [custom configuration as noted on drawings (lite cut subject to approval of Weather
Shield)].
3. Finish: to match sash interior.
I. Grilles-between-glass:
1. Aluminum grilles in sealed airspace: [5/8" (16mm)flat] [11/16" (18mm)sculptured]
2. Pattern: [custom configuration as noted on drawings (lite cut subject to approval of Weather
Shield)].
3. Color: to be selected from one of the manufactures standard colors.
J. Simulated divided lites:
1. Exterior aluminum and interior wood muntins adhered to glass with double-coated acrylic
foam tape:
a. Putty profile exterior simulated divided lite bar options: [5/8" (16mm)] [7/8" (22mm)]
[1-1/8" (29mm)] [2" (51mm)].
b. [Colonial (standard)] [putty] [square] profile interior simulated divided lite bar options:
[5/8" (16mm)] [7/8" (22mm)] [1-1/8" (29mm)] [2" (51mm)].
2. [Adobe aluminum grilles-between-the-glass] [no grilles-between-the-glass].
3. Pattern: [custom configuration as noted on drawings (lite cut subject to approval of Weather
Shield)].
4. Finish: matches exterior/interior sash finish.
2.3 ACCESSORIES AND TRIM
A. Interior installation clips [shipped loose] [factory applied (standard)]: [5-1/2" (140mm)]
[11" (279mm)].
B. Aluminum drip cap: [factory applied (factory-mulled units only)] [shipped loose]. Color to match
exterior frame.
C. Exterior aluminum casings [factory applied (standard)] [shipped loose]: [size and profile from
manufactures standard catalog]. Color to match exterior frame.
D. Interior trim style: [size and profile from manufactures standard catalog]. Wood species:
[match interior frame] [to be selected from one of the manufactures standard]. Finish: [clear
pine] [primed [white] [black]] [prefinished [white] [black] latex] [stained and sealed with color
selected from one of the manufactures standard colors].
Weather Shield Windows & Doors Page 6 of 7 12/21
` SECTION 08 52 13.03
ALUMINUM CLAD EXTERIOR/WOOD INTERIOR DOUBLE-HUNG WINDOWS
E. Wood rosettes: [2-1/2"x2-1/2"x5/8" (64mmx64mmx16mm)] [3-5/8"x3-5/8"x5/8"
(92mmx92mmx16mm)]. Wood species: [match interior frame] [to be selected from one of the
manufactures standard]. Finish: [clear pine] [primed [white] [black]] [prefinished [white] [black]
latex] [stained and sealed with color selected from one of the manufactures standard colors].
PART 3 EXECUTION
3.1 INSTALLATION
A. Install windows according to manufacturer's instructions and reviewed shop drawings to ensure
proper installation and operation.
B. Install window unit plumb, level and square with no distortion of frame members.
C. Fill perimeter frame to wall opening cavity per manufacture's installation instructions.
D. Apply approved sealant in accordance with Section 07 90 00—Joint Protection.
E. Do not puncture aluminum cladding.
3.2 ADJUSTING AND CLEANING
A. Adjust operating sash and hardware to provide tight fit at contact points and at the weather
stripping for smooth operation.
B. Remove excess sealant materials and visible labels from glass. Clean glass surfaces promptly
after installation.
C. Initiate and maintain all protection and other precautions required to ensure windows are in
acceptable condition at time of substantial completion.
END OF SECTION
4
Weather Shield Windows & Doors Page 7 of 7 12/21