Loading...
HomeMy WebLinkAbout48185-Z Y/l7h CAMOIA D E C E � � E RESIDENCE JUL — 6 2022 60 MAJORS PATH SOUTHOLD,NY 11971 BUILDING DEPT. 60 MAJORS PATI I TOWN OF SOUTHOLD SOUTHOLD, NY DRAWING LIST T® o NORTH SCTM#-1000-54.-2-12 A1.00 DRAWING LIST, ABBREVIATIONS, SYMBOLS, & NOTES A2.00 NOTES &ENERGY CODE COMPLIANCE A3.00 EXISTING FLOOR PLAN O A4.00 PARTIAL DEMOLITION PLAN &ELEVATION NORTH PROJECT ` A5.00 PARTIAL PROPOSED PLAN & ELEVATION A6.00 DETAILS & RISER DIAGRAM TAX MAP NO.1000-54.-2-12 NOTE: DO NOT SCALE FROM DRAWINGS. # ISSUE/REVISION DATE .00 FILING SET 06.24.2022 SYMBOLS REGULATORY NOTES 'A' ABBREVIATIONS 1. THIS APPLICATION FOR CERTIFICATE OF OCCUPANCY IS FILED A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD LEVEL WITH THE TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE DRAWN BY:J.LACHAPELLE O THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL CHECKED BY:J.LACHAPELLE WIA NDOW EL. +31'-3" HT HEIGHT ELEVATION ABOVE U-0" 2. THE CONTROLLING CODE IS THE 2020 BUILDING-.CODE OF NEW B.O. BY OTHER HW HOT WATER NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE 2O DOOR YORK.STATE AND THE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL CLG CEILING MTL METAL LaChapelle Architecture PLLC O PARTITION TYPE 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT P.O.Box 1251 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED Mattituck,NY 11952 CONT. CONTINUOUS (646)251-5058 jake@lachapellearchitecture.com 1 1 DETAIL NUMBER 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 A4 SHEET NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. D.H. DOUBLE HUNG O.C. ON CENTER 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DIM. DIMENSION ��RED qR (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. DIA. DIAMETER SIM. SIMILAR ��5 �ACyq cy� DISC. DISCONTINUOUS S.S. STAINLESS STEEL 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DWG DRAWING STL. STEEL JHEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES, w AND REGULATIONS. ELEC. ELECTRIC TYP. TYPICAL n STAIR DIRECTION LABELS ENG. ENGINEER EQ. EQUAL V.I.F. VERIFY IN FIELD ��F 03393 0 00 UP DN INSPECTIONS EXIST. EXISTING W/ WITH OFNEW FL FLOOR WD. WOOD Kcc SEALANT AND BOND SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE BREAKER TAPE REQUIREMENTS OF BCNYS 1704&1705. SCOPE OF WORK occ( SEALANT AND BACKER ROD FRAMING, TIE-DOWN/STRAPPING AND PLUMBING DRAWING LIST, ABBREVIATIONS, PERIMETER INSULATION SYMBOLS, & NOTES ® MATCH LINE ROUGH ELECTRIC THE GENERAL INTENT OF THE WORK IS TO EXTEND THE MASTER CENTER LINE INSULATION AND CAULKING BATHROOM AND MASTER BEDROOM FOR AN ADDITIONAL 38 SF,AND ENERGY CODE COMPLIANCE PERFORM MINOR ALTERATIONS IN THE SECONDARY BATHROOM. NO SHEET NO: BREAK LINE FINAL CHANGE OF USE OR OCCUPANCY IS PROPOSED. Al SHEET 1 OF 6 GENERAL NOTES REGULATORY NOTES ' B' REGULATORY NOTES 'C' CAMOIA RESIDENCE 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 1. THE STRUCTURAL MODIFICATIONS INCLUDED HEREIN MAKE THIS 1. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF A LEVEL 2 ALTERATION UNDER EXISTING BUILDING CODE (EBC) FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND 60 MAJORS PATH DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL CHAPTER 6. REQUIREMENTS OF BC CHAPTER 7 AND 8 APPLY AS A EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE SOUTHOLD,NY 11971 WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A RESULT. INSPECTOR. SYSTEMATIC MANNER. 2. THE PROPOSED STRUCTURAL MODIFICATION WILL BE PERFORMED 2. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE IN CONFORMANCE WITH THE REQUIREMENTS OF 'EXISTING RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND BUILDING CODES,ALL WORK MUST CONFORM TO FIRE BUILDING CODE' SECTION 806 FOR ALTERATIONS LEVEL 2. INSURANCE REQUIREMENTS. TRUE ,.. DEPARTMENT REGULATIONS, UTILITY COMPANY STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.6 NORTH REQUIREMENTS, AND BEST TRADE PRACTICES. BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK 3. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE CATEGORIES AND NOT A HIGH-RISE BUILDING. BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE 3. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH OWNER AND RECEIPT OF WRITTEN CONSENT. PROJECT THE DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL 3. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. NORTH 53°) PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD TAX MAP N0.100054:2-12 INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW 450. n ISSUE/REVISION DATE 4. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY OCCUPANCY R-3. .00 FILING SET 06.24.2022 DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. 4. INTERCONNECTED SMOKE AND CARBON MONOXIDE DETECTION EQUIPMENT MUST BE ADDED IN CONFORMANCE WITH 'EXISTING 5. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT BUILDING CODE' SECTION 804, IF NOT ALREADY PRESENT IN THE NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE BUILDING. WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. 5. THE WORK PROPOSED HERE MUST CONFORM TO ECCNYS R503 REQUIREMENTS FOR ALTERATIONS. DRAWN BY:J.LACHAPELLE 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES CHECKED BY:J.LACHAPELLE WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING 6. AS REQUIRED BY ECCNYS TABLE R402.1.2 THE NEW PERIMETER MANAGEMENT. WALL ASSEMBLY MUST ACHIEVE R-29. SIMILARLY THE NEW NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE CANTILEVERED FLOOR 1 ASSEMBLY MUST ACHIEVE R-19.THE 7. ALL PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY PROPOSED ASSEMBLIES EXCEED THIS. PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE LaChapelle Architecture PLLC FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. 7. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS MUST P.O.Box 1251 CONFORM TO SECTION R404.1: ALL NEW FIXTURES WILL CONTAIN Mattituck,NY 11952 HIGH-EFFICIENCY LAMPS. (646)251-5058 jake@lachapellearchitecture.com INTERIOR DOOR SCHEDULE PLUMBING RISER DIAGRAM RED qR ID TYPE NOTES DIMENSIONS HARDWARE �_ACyq c,S, 1 MASTER BATH DOOR LHR, SOLID CORE WOOD 30"x 80" PRIVACY HALL BATH MASTER BATH ------------ ---------- --------------------------------- 2 LINEN CLOSET DOOR LHR, SOLID CORE WOOD 24"x 80" PASSAGE 1 3 BI-PASS CLOSET DOORS EXIST. EXIST. EXIST. LAV TOILET BATHTUB SHOWER TOILET LAV ; ��� 03393 OQL� 4 HALL BATH DOOR LH, EXIST.TO REMAIN EXIST. EXIST. OF NEW ENERGY CODE COMPLIANCE U-FACTOR/R-VALUE SHGC NOTES & ENERGY CODE COMPLIANCE ID ASSEMBLY MAKE/MODEL NOTES QTY ECCNYS PROPOSED ECCNYS PROPOSED A B DOUBLE HUNG WINDOW ANDERSON 400 LOW-E4 - 1 0.32 0.34(PASS) 0.40 0.31 (PASS) TO HOUSE TRAP SHEET N0: 1 EXTERIOR PARTITION N/A - - 20 29(PASS) N/A N/A 2 �2 CANTILEVERED FLOOR N/A - - 19 30(PASS) N/A N!A SHEET 2 OF 6 CAM OIA RESIDENCE 60 MAJORS PATH SOUTHOLD,NY 11971 ® O s TRUE NORTH FRONT ENTRY PROJECT O NORTH (12.53°) ------------------ - TAX MAP NO.1000-54:2-12 I I DN ------- PORCH ----------------------------------- # ISSUE/REVISION DATE BALCONY / I .00 FILING SET 06,24.2022 I � I I I I - I � I I I I I I I _ DN DINING ROOM BEDROOM BEDROOM I � DRAWN BY:J.LACHAPELLE I I I I CHECKED BY:J.LACHAPELLE I I FAMILY ROOM ............................ - i , NOTE:DRAWING MAY 8E PRINTED AT REDUCED SCALE DN LaChapelle Architecture PLLC ' 00 ; P.O.Box 1251 I Q BEDROOM ; 1 Mattituck,NY 11952 KITCHEN (646)251-5058 jake@lachapellearchitecture.com RE I i ±Hii I ! ------- ;r------ i T I ; I 1 ' D Ay L- ------ - --------- -- --------- ------------------------------------------- --;------------------------------------------------� ! �5 LAC H,qp 01 7'-6" C� F DECK AREA OF WORK REAR PATIO • 03393 QQ� F OF NE`N EXISTING FLOOR PLAN FIRST FLOOR Q Q 1 TRUE PROJECT SHEET NO: SCALE: 1/811 = 11-0" NORTH NORTH (12.53°) A3 SHEET 3 OF 6 I 4'-114" i CAM®IA ---------- PROTECT SINK&CABINET O I RESIDENCE I TRUE PROJECT 60 MAJORS PATH NORTH NORTH SOUTHOLD,NY 11971 DNBATH PROTECT BATHROOM DOOR I (12.53°) PROTECT BASEBOARD HEATER DEMOLISH TILE REMOVE TOILET T® t ------ REMOVE TUB I NORTH REFR. Q RANGE I PROJECT O KITCHEN REMOVE AND PROTECT EXIST. I NORTH CLOSET DOORS ,TRIM, HARDWARE I DEMOLISH WALL I TAX MAP NO.1000.54:2-12 I r IN l # ISSUE/REVISION DATE r DW CM I ------1, ------------- I .00 FILING SET 06.24.2022 ! I LEGEND I l 1 I D EXISTING WALL TO REMAIN 20'-2" l J - I DEMOLISH WALL --------- ----------------------- -- ------ ------------------------ DRAWN BY:J.LACHAPELLE SHORE PRIOR TO DEMOLITION OF WALL REMOVE BASEBOARD HEATER UNDER SINK CHECKED BY:J.LACHAPELLE REMOVE AND DISCARD FIXTURES DEMOLISH DOOR NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE DEMOLISH TILE REMOVE WINDOW LaChapelle Architecture PLLC OFIRST FLOOR - DEMOLITION P.O.Box 1251 1 SCALE: 1/4" = 1'-0" Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture,com ��VED ARC, AREA OF REMOVALS ��ti0. 03393 ® OF NEVI I I PARTIAL DEMOLITION PLAN & ELEVATION l FIRST FLOOR SHEET NO: OELEVATION - EXISTING A4 SCALE: 1/4" = T-0" SHEET 4 OF 6 3 - - CANT®IA 4-1111 4-0 RESIDENCE ---------- :. . I —————————— I 60 MAJORS PATH TRUE PROJECT NORTH NORTH SOUTHOLD,NY 11971 I DN El (12.53°) BATH RE-PLUMB AND INSTALL NEW j TOILET WITH GREATER I CLEARANCE o3 I TRUE ----- NEW TUB, MIXER, FITTINGS I NORTHREFRj__ BEDROOM ® °°� KITCHEN RANGE o NORTH PROJECT MODIFY CLOSET FRAMING AS I O D NECESSARY; REINSTALL DOORS,TRIM, HARDWARE i TAX MAP NO.1000-54.-2-12 NEW SHOWER CONTROLS, 2 ; MIXER, FITTINGS - _ REMOVE EXISTING WOOD a ISSUE/REVISION DATE ----- FLOOR AS NECESSARY TO ----------_�iEll 1--------- O BLEND NEW FLOOR; REFINISH I .00 FILING SET 06.24.2022 1 1 11 BEDROOM I LEGEND - D EXISTING WALL TO REMAIN I - I �- --------- ---------------------- ------- _________ NEWWALL MASTER BATH DRAWN BY:J.LACHAPELLE 8'-3" O O CHECKED BY:J.LACHAPELLE 21'-3" PROVIDE NEW DOOR NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE NOTE: PROVIDE PLYWOOD CONSTRUCT NEW WALLS BLOCKING IN BOTH SHOWER PROVIDE NEW LINEN CLOSET, DOOR,SHELVES LaChapelle Architecture PLLC AND TUB AND AT BOTH TOILETS PROVIDE NEW FIXTURES, INCLUDING TOWEL RODS,TOILET PAPER HOLDERS, ETC. P.O.Box 1251 OFIRST FLOOR - PROPOSED FOR FUTURE ADA GRAB BARS 1 SCALE: 1/4" = 1�-011 PROVIDE NEW SURFACE-MOUNT MIRROR Mattituck,NY 11952 PROVIDE NEW PORCELAIN TILE IN BOTH BATHROOMS AS SELECTED BY OWNER (646)251-5058 fake@lachapellearchitecture.com -FRED A6 t ACy� ALIGN ALIGN < R, ROOF TO REMAIN m ..z PTD. CEDAR SHINGLES TO MATCH EXIST. ® FF RETURN SHINGLES AT ENDS OF ADDITION AND ti �� 0339313 FINGER INTO EXIST. F NEIN _j Ltd- 7F] PARTIAL PROPOSED PLAN & ELEVATION FIRST FLOOR SHEET NO: OELEVATION - PROPOSED llffffffEL, EL. +0'-0" A5 SCALE: 1/4" = T-0" SHEET 5 OF 6 NEW PLYWOOD CAM®I/4 GUSSETS AT TRUSSES; SEE 2 PLYWOOD RESIDENCE STRUCTURAL �� 1 EXIST.2x4 TRUSS EXISTING TRUSS(2x4 60 MAJORS PATH DIAGRAM FOR INFO GLUE LAYER CHORDS, ETC.) SOUTHOLD,NY 11971 �? a VERIFY EXIST. I SUPPORT POST EXIST. AOR APPROVED OVERHANG X _ TRUE C—D BUILDING WRAP W/ I I 2'-0" NORTH a VAPOR I I END VIEW ¢ PERMEANCE BTWN 6.5 AND 30 PERMS; I I PROJECTNORTH O ALSO USE i MINI 41-0" — NEW""PLYWOOD GUSSET BOTH c125a^> NARROW CAVITY I I c=n 2 I z_ SIDES OF TRUSS; TAX MAP NO.1000-54.-2-12 DRAINAGE PLANE • GLUE TO 2x4 TRUSS MEMBERS- SUCH AS SLICKER I I U- I 1 ALL SURFACE AREAS # ISSUE/REVISION DATE o BY OBDYKE REAR OF HOUSE I I 0o • SCREW W/WOOD SCREWS @ 12" G I 0 I I 0 X O.C.TO ALL MEMBERS .00 FILING SET 06.24.2022 LU j I ALL TRUSSES EXPOSED BY NEW JAMB I I z PORCELAIN I I a OPENING TO BE GUSSETTED I I TILE PER NEW EXTERIOR PARTITION J SHORE BUILDING PRIOR TO I OWNER IN I 1 DEMOLITION OF EXISTING WALL BATHROOM I I ON CEMENT 2x6 STUD PTD. EXTENSION AT c=i� BACKER DRAWN BY:J.LACHAPELLE FRAMING,TYP. WINDOWS, PROVIDE I I p BOARD OVER APPROX.GRADE PROVIDE NEW 2x10 SISTERED JOIST TRIM TO MATCH EXIST. 3'-0" CHECKED BY:J.LACHAPELLE 2"CLOSED-CELL o = w PLYWOOD EXTENSION AT EACH EXISTING 2x8 SPRAY FOAM SQ10 SUBFLOOR JOIST;ALIGN TOP SURFACES AND INSULATION(R-14) @ 2 3i OAK NOTCH OVER SILL PLATE NOTE:DRAWING MAY BE PRINTED AT REDUCED SCALE PLUS 3 2'BATT p I I FLOORING TO FASTEN w/2'DIA. BOLTS @ 12"O.C. MINERAL WOOL w I I MATCH EXISTING STAGGERED, MIN. 1Z'FROM EDGE OF LaChapelle Architecture PLLC LLJINSULATION(R-15) z I I IN BEDROOM, EXIST.JOIST P.O.Box 1251 FOR WHOLE ASS'YI I PROVIDE SOUND- Mattituck,NY 11952 MIN. R-29 LU HOLD I DAMPENING 2 STRUCTURAL DIAGRAM (646)251-5058 jake@lachapellearchitecture.com UNDERLAYED O SCALE: 1/4" = T-0" PTD. CEDAR SHINGLE SIDING 4"PLYWOOD TO MATCH EXIST. 1 PTD.WOOD I I SUBFLOOR �E42ED q BASE TRIM TO I I GLUED& �c, LACY Rc 7"MINERAL WOOL MATCH EXIST. I I SCREWED TO JO INSULATION(R-30) I>. ®�> >i �I♦> �w�a row» �t® >■ ®a�,�>.rr� �R,r, STS 4'PLYWOOD - - - - - - - -- - r Na SHEATHING;GLUE @ &SCREW NEW 2x10 RIM 0033933 NO " JOIST @ N 2 - CEMENT BACKER �`�,�� ----- -- -------------------------------------- BOARD BY JAMES t HARDI;GLUE& ® ® 3'-0" SCREW TO JOISTS -® APPROX. 5'-6" DETAILS & RISER 2 1x4 PVC TRIM NEW SISTERED 2x10 JOIST EXIST.2x8 FLOOR JOISTS DIAGRAM EXTENSION; SEE STRUCTURAL REPLACE EXIST. RIM JOIST WITH BLOCKING BTWN. NEW JOISTS EXIST. PAVERS DIAGRAM FOR INFO PROVIDE BLOCKING FOR SHEET NO: ATTACHMENT OF NEW SUBFLOOR CELLAR OTYPICAL SECTION DETAILS EXIST.CMU CELLAR WALL A6 SCALE: 1z" = 1�-� SHEET 6 OF 6