Loading...
HomeMy WebLinkAbout47856-Z © vat FO(k-oGy Town of Southold 6/30/2022 o P.O.Box"1179 o • 53095 Main Rd 4,1 dao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43207 Date: 6/30/2022 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 615 Hummel Ave., Southold SCTM#: 473889 Sec/Block/Lot: 63.-2-19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application.for Building Permit heretofore filed in this office dated 3/16/2022 pursuant to which Building Permit No. 47856 dated 5/26/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as-built"front porch altered to habitable space to existing two family dwelling as applied for. The,certificate is issued to Wickham,Gekee&Thomas of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47856 6/28/2022 PLUMBERS CERTIFICATION DATED Au ori ed ature TOWN OF SOUTHOLD �o�sUFFotK�oa y BUILDING DEPARTMENT C, x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47856 Date: 5/26/2022 Permission is hereby granted to: Wickham, Gekee 1230 W Creek Ave PO BOX 1122 Cutchogue, NY 11935 To: Legalize as-built front porch enclosure and conversion into habitable space. Additional certification may be required. At premises located at: 615 Hummel Ave., Southold SCTM #473889 Sec/Block/Lot# 63.-2-19 Pursuant to application dated 3/16/2022 and approved by the Building Inspector. To expire on 11/25/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $560.00 CO-ALTERATION TO DWELLING $50.00 Total: $610.00 Building Inspector Of SOUryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin GG.town.southold.ny.us Southold,NY 11971-0959 c4UNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Gekee Wickham Address: 615 Hummel Ave city:Southold st: NY zip: 11971 Building Permit#: 47856 Section: 63 Block: 2 Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1 st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 4 Ceiling Fixtures 3 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures 3 Smoke Detectors 1 Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 7 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Front Porch Converted to Living Space Inspector Signature: Date: July 1, 2022 S.Devlin-Cert Electrical Compliance Form OF SOUI - - -� W 15- Pf p I l,M cd f # TOWN OF SOUTHOLD BUILDING DEPT. ourm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING 1 STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) (' ELECTRICAL (FINAL) [ ] CODE VIOLATION [ /] PRE C/O [ ] RENTAL REMARKS: I ' c or DATE 2I ZZ INSPECTOR pf 50Gj TOWN OF SOUTHOLD BUILDING DEPT. `ycn631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 0 r"e,(&- DATE INSPECTOR sigh- 7 !' 1 � ( C mad �F S0Lk I �c->o�S i i 5 - - I I--------- - ------ yv � v 7 i 5� s I F FIELD INSPECTION REPORT DATE COMMENTS, FOUNDATION(IST) -------------------------------------- FOUNDATION(2ND) 01 . - � H ROUGH FRAMING& . PLUMBING H r- r INSULATION PER N.Y. (� y STATE ENERGY CODE (� FINAL ` v- ADDITION4 C .MMENTS . -l3-aa I t 100-00" t v C�21 0 Z rn e� N p cN z . d r� b H t S ff01 �4�0 CSG TOWN OF SOUTHOLD = BU I LD I NG-DEPARTMENT H Z Town Hall Annex 54375 Main Road P. 0.. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT N0. t!/ Building Inspector: ® E C E :. F, r w MAR 1 6 2n?2 Applications'and'form's,must,be"filled outJn their';entirety..Irn;o"mplete""";'.a; :applications'will not be_.accepted..Where the Applicant:is notch"e'owner,6rt-,' BUILDING DEPT. 'Owner's`'-Autfio"riation.form'.(Page 2)'shall,be completed..;"; TOWN OFSOUTHOLD Date: O' ER S N ;OF PROPER ,W � .� TY:g Name:Gekee Wickham scTM#1000-63-2-19 Project Address: 615Hummel Ave 971 11971_....-.._ ._.... .....___......_...-m..... .. . _...,.... _......._...._.. Phone#: 631-255-6667 Email:gek2@,vaho0_.coCll -_.-... .__._.._ ...._ _ MailingAddress: PO Box 1122 CutChogue, .NY_11935--____._._..___.__......_ C0 PE NTA' T RSON': Name:Gekee Wickham Mailing Address: PO BOX 1122 CutChogue", NY 11935 . Phone#:63.1_-255-6667_... . .... _....................... ......__.__.._.. _._._ Email:g.e.k2@vaho.o.com_ DESIGN,;PROFESSIONAL".IN' 6-"' ATION: i•" NameDaniel Karpen MailingAddress.3 Harbor"Hill mDrive,..Hu-ntington, NY. 1v1.743._ _.-_. ._-._._.._.__...._ _... __..µ._._......_...__. Phone#:6317427-0723 Email: - 'r R,; C,ONTRACTOR:INF,ORMATION: Name:Juan A Monzon Mailing Address: PO .BOX}203.._CutChog_ue,._NY_1.1.935. .._. ..._._ .... .._...._...._........._.. ... _._.......... _... ..__ Phone#:631 -276-4733 Email: DESCRI PTION,OF'PROPOSED:C0 NSTRUCTION ... . ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Eil Other Porch to habitable part of house $5,000 F\Arill the lot be re-graded? ❑Yes 8No Will excess fill be removed from premises? ❑Yes ®No 1 " PROPERTY INFORMATION Existing use of property: Intended use of property: .. ., Residential _ . . . Rest -entia _-_~ _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ®No IF YES, PROVIDE A COPY. ® Check Bax"After"Reading: The owner%contracto'Jl 'Osign professional is responsible for,all,drainage,anId storm water issues as provided by Chapter 236 of;the Town Code.-APPLICATION IS HEREBY MADE to the Building Department for thel ssuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk ,County,New York and other applicable Laws,Ordinances or.Regulations,for the construction'of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with ail•applicable laws,ordinances;"building code, housing code and regulations and tc admit authorized inspectors on.premises and in buildings)for necessary inspections.False statements made herein are ` punishable as a Class A misdemeanor pursuant to Section 210.45•of the New York State Penal Law. .' Application Submitted By(print name):Gekee Wickham ❑Authorized Agent gOWner Signature of Applicant: , Date: March 16, 2022 STATE OF NEW YORK) ,,'' ��rr �/SS: COUNTY OFSuTT6I`� ) l-i c, ee— W i a being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the ChOnCk. (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this h f day of (rC ,202-2— otaryf �Y HA-c L. MYER NOTARY PUBLIC,STATE OF NEW YORK NO.01 Dw6306900 PROPERTY OWNER AUTHORIZATION- QUALIFIED IN SUFFOLK COUNTY (Where the applicant is not the owner) OMISSION EXPIRES JUNE 30,2-02a I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 S�ff01,� BUILDING DEPARTMENT- Electrical Inspector �0� COGy:'c TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 ytj0. app Telephone (631) 765-1802 - FAX (631) 765-9502 1 " rogerr(D-southoldtownny.gov - seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFO TION (All information Required) Date: ep-/3•i.2, Company Name: 6 Electrician's Name: ��•Q,�' .e License No.: 4/0,:2 -MLZ Elec. email: eG�r;c O dh ih4e Elec. Phone No: S-/d3o l�I request an email copy of Certificate of Compliance Elec. Address.: 97S S Ll e JOB SITE INFORMATION (All Information Required) Name: aj -akee Q y t Address: S a w e Cross Street: p u !? S Phone No.: Bldg.-Permit#: - 41-7eS email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): arm ��y "11D U u/ P- /`�G 7 G Squgke F tage: Circle All That Apply: Is job ready for inspection?: KI YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES�O Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 02 0 H Frame Pole Work done on Service? Y ON Additional Information: PAYMENT DUE WITH-APPLICATION ,�`v �2 jog \0 b CP SOFot� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C2 - Town Hall Annex- 54375 Main Road- PO Box 1179 Southold, New York 11971-0959 y p� Telephone (631) 765-1802 - FAX (631.) 765-9502 rogerr(D-southoldtownny.gov — seandOa southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION . ELECTRICIAN INFO TION (All Information Required) Daat�e: zp-/.3.1.2 P Com any Name: �-P�S'-PYA e l')G C & • Electrician's Name: 0- � er- -e License No.: 4/Q; Ind::- Elec. email: eG�I"iG O dij? h e Elec. Phone Nob r� , -IX3 IBJ I request an email copy of Certificate of Compliance Elec. Address.: &'S S;Lr/ e JOB SITE INFORMATION (All Information Required) Name: a o-k e e 6Ut'e— Aa w Address: Cross Street: p u h S Phone No.: �p Bldg.Permit#: ?of,S email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly: p,(DrCh � k� I ; V'l /19 5 u! /741- e, -/r; c�- Squake F . tage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES O Issued On Temp Information: (All information required) Service Size F11 PhF]3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground[]Overhead # Underground LateralsF11 2 H Frame Pole Work done on Service? 0 Y FIN Additional Information: PAYMENT DUE WITH APPLICATION \off' b � PERMIT # Address: Switches Outlets' GFI's I Surface Sconces M H H's UC Lts Fans Fridge HW Exhaust Oven WAD Smokes DW Mini Carbon Micro Generator Combo Coo ktop Transfer AC AH Hood Service Amps Have Used Special: Comments ACCOR" CERTIFICATE OF LIABILITY INSURANCE DATE 03//15/2015120YYYY) 22 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: CHRISTOPHER MANFREDI PHONE FAX A C No Ext): 'AIC No PO BOX 1345 E-MAIL ADDRESS: SOUTHOLD NY 11971 INSURERS AFFORDING COVERAGE NAIC# INSURERA: UTICA FIRST INSURED INSURER B: MONZON HOME IMPROVEMENTS INSURER C: JUAN ANTONIO MONZON LOPEZ INSURER D: PO BOX 203 INSURER E: CUTCHOGUE NY 11935 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM DI POLIC LTR DY EFF MM DD EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE Fx_]OCCUR PREMISES Ea occurrence) $ 50,000 MED EXP(Any one person) $ 5,000 A ART5078813 12/01/2021 12/01/2022 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY❑JjECT LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PeOPERT accident) $ HIRED AUTOS AUTOS $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED RETENTION$ $ T H- WORKERS COMPENSATION AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS 1 VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN TOWN OF SOUTHOLD ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 AUTHORIZED REPRESENTATIVE PO BOX 1179 /��_ � 7-fA SOUTHOLD NY 11971 ©1988-2014 ACORD CORPORATI . All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Suffolk County Dept.of Labor,Licensing&Consumer Affairs . HOME IMPROVEMENT LICENSE Name JUAN A MONZON Business Name >certifies that the irer is duly licensed MONZON HOME IMPROVEMENT be County of suffolk License Number:H-56432 Rosalie Drago Issued: 02/04/2016 Commissioner Expires: 2/1/2024 i" 4 Dwyer, Nancy From: Dwyer, Nancy Sent: Tuesday,April 19, 2022 3:07 PM To: gek2 Wickh' Subject: RE: 615 Hummel We still need that basic info added to the drawings. We also need it indicated on the survey as to which portion of the house this work is taking place. From:gek2 Wickh<gek2@yahoo.com> Sent:Tuesday,April 19, 2022 3:06 PM To: Dwyer, Nancy<nancy:dwyer@town.southold.ny.us> Subject: Re: 615 Hummel This is an existing porch that was built a long time ago, even before I bought the house. Sent from my iPhone On Apr 19, 2022, at 2:48 PM, Dwyer, Nancy<nancy.dwyer@town.southold.ny.us>wrote: Good afternoon Gekee, I am looking at your application for the porch at Hummel Avenue. Please note the plans provided are very vague. There is no structural information given regarding the floor construction,walls, ceiling, roof,foundation etc. What kind of habitable space is this.. how is it being used? This info is required, as well as a building section showing depth and heights. Additionally,where on the house is this being proposed? Your design professional should draw a site plan showing this area, if not, at the very least, mark on the property survey where this work is taking place. I can not issue a building permit based on what is provided. If you or your design professional have any questions regarding the additionally requested info, please feel free to reach out to the building department. Thank you, ✓111ayccy D7vye,- Building Permits Examiner Town of Southold Building Department Annex Building 54375 Main Road Southold,NY 11971 (631) 765-1802 i Dwyer, Nancy From: gek2 Wickh <gek2@yahoo.com> Sent: Friday, May 13, 2022 12:44 PM To: Dwyer, Nancy Subject: 615 Hummel Ave ny 11971 Hello Nancy Just an FYI that I am selling the property and it will be owner occupied, so the rental permit is no longer needed. Thanks for your time and patience. Gekee Wickham Sent from my iPhone ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 DANIEL KARPEN PROFESSIONAL ENGINEER &CONSULTANT, P.C. 3 HARBOR HILL DRIVE HUNTINGTON,NEW YORK 11743 (631)427-0723 www.danielkarpen.com March 5, 2022 Gekee Wickham P. O. Box 1122 Cutchoque, New York Dear Gekee: RE: 615 Hummel Avenue, Southold Please find enclosed 7 sets of design drawings, which include detailed energy notes. Please note that after my inspection, I determined by reading the present energy code, that you will have to install a new weatherstripped door between the basement and the crawl space. It has been a pleasure to serve you. Please call me at the above number if you have any questions. Respectfully submitt d, Daniel Karpe Paramount Fabrication 6 Teak Court Lake Grove,NY 11755 INVOICE# Phone(631)492-0214 Fax(631)467-2313. DATE.)UNE 9,2022 TO: Geekee Wickham SAME 615 Hummel Ave Southood,NY DESCRIPTION AMOUNT Insulation Workscope: Supply and install dense pack blown Cellulose insulation in(3)front exterior walls. Remove and replace vinyl siding as needed. Newly installed insulation has a total of R15 @ 4". Supply and install blown Cellulose insulation in front roof cavity. Newly installed insulation has a total R38 @ 10". Greenfiber"Sancuatary"brand Celkulose insulation was used in both areas. MSDS is included on separate document. D DD J U N 2 7 2022 BUILDING /�yg���� L��B.%ppJ.1g 1. OF TOTAL M®NZON HOME IMPROVEMENTS PREMISES: 615 Hummel Ave Southold,NY 11971 June 25, 2022 Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of/4"plywood. Contractor: Monzon Home Improvements Antonio Monzon ; Licensed and Insured 631-276-4733 r D JUN 2 7 2022 BUILDRiG DEPT. TOWN OF SOUTHOLD SUIS -LY OF ROPERTY 51TUATE: 5OUT -LI? N TOM 5OUTHOLD SUFFOLK OOUNTY, :11'i' SURVEYED 06-30-2004 SUFFOLK COUNTY TAX # 1000-63-2-Iq CHR'IIM71M TO: Ockee Wickh m \ 0� Stewart Title Insurance Company �o('��Q \ko 0'ca 0'f\ lei 46 O/e�om 5r dam. / o 4\ O `dm O QQ y N 0 O O \ c O O ��o \O \ O O o �o o k" \ \ �oPP�oe . 0 9� � • 9 �' ddey- 91 979- 2 Od`' L C\AOvG�� r F oe 0° O zy c m 0 �' c6 lO � cc \X WD 563 �3� me�ti S 0 �• p��.,�" •.�er, C. p-- S-�, �Q �L4autharl[ed a¢eroNon or addition t o Survey map bear4lg a licensed land zurveyar's seal Is o vloiatinn of section'1209,sub-tllvion 2,of the Nen York isState EWLOLIan Lor" �( •only coplez from the origki,l of this—,j -ked nith an original of the land surveyor's `.'° stomped seal shall ae aonsldered to t,valitl true °Lertifications Indlcoted hereon slg,nify,that lhlf NOTES: rvey ea=prepared 0 accordance nIth the e.- _ ,a(\ istlny Gode Pr, for Lwd Surveys adopted PIPE FOUND' 1 ^ Q/�9T by the New York 5tat Associptlon of Professlowl O �y7" Lt!ne persfz.la�rhom thecsutrvey prepared nlz behalf!o the title yov �AN® � eal agency and lending InztnvN-on-lKt—ea herean,ra�a to the assignees of the lending Institution, LertiNca- Hong are not tronsferable to odd1LWn 1 tr tlWtl- AREA = 12,260 9f or 0.28 or-res JOHN C. E LERS LAND SURVEYOR 6,EAST MAIN STREET N.Y.S.LIC.NO. 50202 GRAPHIG SCALE I 20' RIVERHEAD,N.Y. 11901 369-8288 Fax 369-8287 REF.\�Hp server\d\PROS\04-231.pro 1/1] 9,99.IlPM rvuwx+a�i�d-]31 0 I un Additional �-� = IS UNLAWFUL APPROVED AS NOTED Certification a-10UT CERT1F!r,a"_7r DATE: 5a_ B•P• May q Ma Be Required. FEE$- BY: ® �� �,�. . :..- OCCUPANCY, NOTIFY BUILDING DEPARTMENT AT ," , I L�� 765-1802 8 AM TO 4 PM FOR THE ���/ �f 11 b/STS I ���� EXISTING HOUSE N(ao r�l;�C` L GO�3f<S OF FOLLOWING INSPECTIONS:1. FOUNDATION • TWO RFO� IRED !l ty 7- 022 1 NEW YORK STATE & TOWN CODES FOR POURED CONCRF "= L 6U'LUjrvG DS AS REQUIRED ND CONDITIONS OF 2. ROUGH -. FRAMING & PL:...;MBING TO 6.0 .OF,SO . INSULATION Hod_D 3 SOUTHOLDTOWN ZBA 4. FINAL = ENERGY NOTES Work to be done: Insulate attic, walls, floor, and install new door'to crawl space. Insulate attic by drilling holes in ceiling every 16 inches between rafters, blow in fiberglass insulation to achieve R-49 required by Table R-402.1.2 of NYS Energy Conservation Construction 'UA as designed: For walls, the total R value is the total of the sum of the various wall components: Outside air film (R= .17), wood sheathing (R = 1.0), insulation (R = 14), gypsum Code (climate zone 4). Spackle holes, repaint as necessary to match existing paint. board (R = .6), and inside air film (R = .68). Total R value is 16.45. U = .061. UA = 16.77. Insulate walls from inside by drilling holes every 16 inches between studs, blow in fiberglass Sum of the designed UA is 5.83 plus 16.77 or a total of 22.60, compared with a total required insulation to achieve R-14 in stud cavity, fiberglass blown in insulation R-4 to the inch, 3.5 inch UA value of 21.64. cavity. Spackle holes, repaint as necessary to match existing paint. Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly CONCLUSION : Code requirements are met by the designed insulation with UA values close between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation enough for compliance. in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of 3/ inch plywood or similar material. New door shall be weatherstripped according to R-402.2.4 of NYS Energy Conservation Construction Code. Table R-402.1.2 of NYS Energy Conservation Construction Code requires R-20 or 13+5. What this means is R-13 cavity insulation and R-5 continuous insulation. Table R-402.1.2 requires R- 19 floor insulation in crawl spaces. Because the code can not be met just by insulation of the stud cavities, a trade off will be largely met by installing more insulation under the floor to offset the inadequacy of the blown v�✓Ya in stud intsulation. '� ,� v Area of floor from Sheet A-101 is 188 square feet. Area of walls from Sheet A-101 is 275 square feet after subtracting the area of windows and a�..X doors. UA is the product of the u value (1/R) and the area of the walls or floors. w UA required by code: To simplify calculations, units will be left out of final calculations. Floors: 1/19 BTU/hr-deg x 188 square feet = 9.89 - Walls: 1/20 BTU/hr-deg x 275 square feet = 13.75 la04 1?&s<4�Z,5' DANIEL KARPEN Total UA value is 21.64 5— M eI PROFESSIONAL Eh1�GINEER&Ce:;NSZTLl'AN-1%1 p "' u � �� •Building Inspections �� 7 ��y' •Energy Conservation Consulting UA as designed: For floors, the total R value is the sum of the various floor components: oak 1 [ / / •Full Spectrum Polarized Lighting i flooring (R = .70), pine subfloor (R = 1.0), insulation (R= 30), and gypsum board (R = .6). Total R �� moo�6� - 1 90ironmental Conservation •Expert Testimony value is 32.3. U = .031. UA = .031 x 188 = 5.83. •Patents and Inventions Y �0�� 3 Harbor Hill Drive•Huntington,New York 11743 i www.danielkarpen.com (631) 427-0723 SURVEY OF PROPER—TY SITUATE: SOUTHOLD TOWN: SOUTHOLD N SUFFOLK COUNTY, NY W e f E SURVEYED 06-30-2004 SUFFOLK COUNTY TAX # 1000-63-2-1 G CERTHqEiD TO: Cuekee Wickham of Stewart Tide Insurance Company � �p g��y \`SOV`�'�'���� / •,�O'ON V0., Ocj� 0q�5'3� Fid 5 %d NIMAY, ZgHi \ 4\ a. O y- 5 Ft�J \ O \.0W \ o o\ t \ \ o 6.9 LAO pot \� o O c Oil �!\ \ O pOt\p\;\OP O (�I' p \ \ - - - � + WOOa eQy 9. o 7 N `cr 7 o \ N, \Aov� o •�� J ° y o FE z5 � L/ d$ J � �r J a S \ \ \ 0015�20 e�e�� o Q i E;. fir// �C•[�'�rt v,mmoriznd a¢erauon or odartlon Lo n su-.oy Sf �'.J � "gyp s mop mashy a Ilcensed 0%surveyor's sent I.a l7ff) vblatbn of section 1 t,t,E slon 2,of ILI— I,— ' York State En�caLion Lar' If SM1 'Only copies from LM Al lrlk3 al of 115 wrvcy t rn nill,an or'ngFvl or!M Imd surveyor's stamped -seal soon ne cnnsbared to Ise vnnd wa :..'� 1 •_ r��ti``U abayne enon llalsFpicnae[sann laVlrtllnceMotmeatl r lLwreon sign ly LMl oIN, NOTES: cweMp"ed the Nn York 5.1 1r a- y l SrvyoSold 11—1 tM wy 1,Fepad.O PIPE FOUND rMf to uu;l¢le compmy govern�Wr /;]'�„'� /T' Lai agercy a,tl Inndhy Instlwlbn Ilsled Mrroh ane '' __ �-....•-.�'r u,a asskjnees nr tna Inn<n.g wsutuuon.eeruraa- , � --” L flans are ml transrcrrhile to addl[law.l_InsLitutbns AREA = 12,260 5f or 0.28 acres JOHN Ca EHL ERS LAND SURVEYOR 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 GRAPHI SGALE 120' RIVERHEAD,N.Y. 11901 !1 �— 369-8288 Fax 369-8287 REF.\\Hp server\d\PROS\04-231.pro o .y EXISTING HOUSE NO CHANGES CLOSET CLOSET E C Eo V MAR 16 2022 BUILDING 1 V-6" —121—51 2," TOWN OF SOUDTHOLD EPT co C) _ tit. / PORCH CONVERTED TO HABITABLE SPACE ti X - \ X Fes '+ Ft W co c/) B W �S M e a DANIEL ARP-.PN �i� � � kv PLAN _- .� •Building'Inspections e _ ./7 U)� •Energy Conservation Consulting / 2 — 11 - 011 1 `'! ®Full Spectrum Polarized Lighting .1;n�ironmental Conservation •Expert Testimony T / --�3-2.-1 •Patents and Inventions 3 Harbor Hill Drive-Huntington,New York 11.743 /) r . _ J 191www.danielkarpen.com (631)427-0723 ENERGY NOTES Work to be done: Insulate attic, walls, floor, and install-new door'to crawl space. Insulate attic by drilling holes in ceiling every 16 inches between rafters, blow in fiberglass insulation to achieve R-49 required by Table R-402.1.2 of NYS Energy Conservation Construction 'UA as designed: For walls, the total R value is the total of the sum of the various wall components: Outside air film (R= .17), wood sheathing (R = 1.0), insulation (R = 14), gypsum Code (climate zone 4). Spackle holes, repaint as necessary to match existing paint. board (R = .6), and inside air film (R = .68). Total R value is 16.45. U = .061. UA = 16.77. Insulate walls from inside by drilling holes every 16 inches between studs, blow in fiberglass insulation to achieve R-14 in stud cavity, fiberglass blown in insulation R-4 to the inch, 3.5 inch Sum of the designed UA is 5.83 plus 16.77 or a total of 22.60, compared with a total required cavity. Spackle holes, repaint as necessary to match existing paint. UA value of 21.64. I z CONCLUSION : Code requirements are met by the designed insulation with UA values close Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation enough for compliance. } in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of% inch plywood or similar material. New door shall be weatherstripped according to R-402.2.4 of NYS Energy Conservation Construction Code. Table R-402.1.2 of NYS Energy Conservation Construction Code requires R-20 or 13+5. What this means is R-13 cavity insulation and R-5 continuous insulation. Table R-402.1.2 requires R- 19 floor insulation in crawl spaces. Because the code can not be met just by insulation of the stud cavities, a trade off will be largely met by installing more insulation under the floor to offset the inadequacy of the blown OF �y T in stud insulation. Area of floor from Sheet A-101 is 188 square feet. Area of walls from Sheet A-101 is 275 square feet after subtracting the area of windows and . E C EMgr doors. G MAR 4 ,•�~ g,�.7 a� UA is the product of the u value (1/R) and the area of the walls or floors. BUILDING DEPT. TOWN OF SOUTFiOLD ` UA required by code: To simplify calculations, units will be left out of final calculations. 6 Floors: 1/19 BTU/hr-deg x 188 square feet = 9.89 Walls: 1/20 BTU/hr-deg x 275 square feet = 13.75 DANIEL, KARPEN l �� 4LI PROFESSIONAL EP•IOI1�EER&CON;ZFANT,?'+ Total UA value is 21.64 � V M VU •Building Inspections 7.�/ / y •Energy Conservation Consulting UA as designed: For floors,the total R value is the sum of the various floor components: oak �(�Gc/ I G [� /� / •Full Spectrum Polarized Lighting a flooring (R = .70), pine subfloor (R = 1.0), insulation (R= 30), and gypsum board (R = .6). Total R rc_7 1;00 �_Z 1 c� 9 ironmental Conservation I •Expert Testimony value is 32.3. U = .031. UA = .031 x 188 = 5.83. •Patents and Inventions if�y //�O 3 Harbor Hill Drive•Huntington,New Fork 11743 www.danielkarpen.com (631) 427-0723 EXISTING HOUSE NO CHANGES ® E C E YE O, CLOSET CLOSET MAS 1 6 222 ' TOM OF MW .. 1 1,-6" 12'-52" , 0o I v OF L it PORCH CONVERTED TO HABITABLE SPACE _ o z � 1 I..n. c1 ., w.��`v`•y .d� M• X � Lf) x 10F� �64. ,, U) _ W Co X t$SI 1�AL 11 �_6�, wr) 1�: wH(-.�...M1 J HT MA4A- v�II�JVi IH: r.V. PLAN •Building Inspections r r _ r r r l °Energy Conservation Consulting / 2 — — O �c,14 O b0 �` °Full Spectrum Polarized Lighting lrivironmental Conservation F •Expert Testimony Tb`J -.Patents and Inventions 3 Harbor Hill Drive°Huntington,New York 11743 www.danielkarpen.com (631)427-0723 ENERGY NOTES Work to be done: Insulate attic, walls, floor, and install new door•to crawl space. Insulate attic by drilling holes in ceiling every 16 inches between rafters, blow in fiberglass insulation to achieve R-49 required by Table R-402.1.2 of NYS Energy Conservation Construction 'UA as designed: For walls, the total R value is the total of the sum of the various wall components: Outside air film (R= .17), wood sheathing (R = 1.0), insulation (R = 14), gypsum Code (climate zone 4). Spackle holes, repaint as necessary to match existing paint. board (R = .6), and inside air film (R = .68). Total R value is 16.45. U = .061. UA = 16.77. Insulate walls from inside by drilling holes every 16inches between studs, blow in fiberglass insulation to achieve R-14 in stud cavity, fiberglass blown in insulation R-4 to the inch, 3.5 inch Sum of the designed UA is 5.83 plus 16.77 or a total of 22.60, compared with a total required cavity. Spackle holes, repaint as necessary to match existing paint. UA value of 21.64. Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly CONCLUSION : Code requirements are met by the designed insulation with UA values close between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation enough for compliance. in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of% inch plywood or similar material. New door shall be weatherstripped according to R-402.2.4 of NYS Energy Conservation Construction Code. Table R-402.1.2 of NYS Energy Conservation Construction Code requires R-20 or 13+5. What this means is R-13 cavity insulation and R-5 continuous insulation. Table R-402.1.2 requires R- 19 floor insulation in crawl spaces. Because the code can not be met just by insulation of the stud cavities, a trade off will be -- largely met by installing more insulation under the floor to offset the inadequacy of the blown � � y in stud insulation. qac. Area of floor from Sheet A-101 is 188 square feet. Area of walls from Sheet A-101 is 275 square feet after subtracting the area of windows and , doors. c4e�i�" UA is the product of the u value (1/11) and the area of the walls or floors. UA required by code: To simplify calculations, units will be left out of final calculations. Floors: 1/19 BTU/hr-deg x 188 square feet = 9.89 Walls: 1/20 BTU/hr-deg x 275 square feet = 13.75 DANEEL KARPEN = /� / �� TROFESSIONA?�NG;i SER i PVS uL I'Al�i,'?' Total UA value is 21.64 17(�` oM / •Building Inspections UA as designed: For floors the total R value is the sum of the various floor components: oak �(>/,d ( !� ��-/ i Energy Conservation Consulting ; g p Full Spectrum Polarized Lighting J flooring (R = .70), pine subfloor (R = 1.0), insulation (R= 30), and gypsum board (R = .6). Total R -6� Z �1 Environmental Conservation •Expert Testimony value is 32.3. U = .031. UA= .031 x 188 = 5.83. SIA Patents and Inventions (�Y /N 0�- 3 harbor Hill Drive•Huntington,New pork 11743 ; www.danielkarpen.com (631) 427-0723 EXISTING HOUSE NO CHANGES o. CLOSET CLOSET MAR 1 6 2n7 BUILDING DF-PT 1 1'-6 12'-5-, -rowwN OF SOUVaLD Z _ °0 -� OF E_4 PORCH CONVERTED TO .HABITABLE -SPACE � x AA LU cn Z a i"1 � l G�— DANiEZ, KARPFN L A N f V e -"�SSivi\?t �i� �(�Wl WL� �- •Building Inspections �• S 1 ®Energy Conservation Consulting 2 _ ® �(/Z��"�U�� ""` •Full Spectrum Polarized Lighting ) nviro! tal Conservation •Expert Testimony Tl� /G —6 3—2—1 ; •Patents and Inventions . 3 Harbor Hill Drive•Huntington,New York 11.743 www.danielkarpen.com (631) 427-0723 ENERGY NOTES Work to be done: Insulate attic, walls, floor, and install new door:to crawl space. Insulate attic by drilling holes in ceiling every 16 inches between rafters, blow in fiberglass insulation to achieve R-49 required by Table R-402.1.2 of NYS Energy Conservation Construction 'UA as designed: For walls, the total R value is the total of the sum of the various wall Code (climate zone 4). Spackle holes, repaint as necessary to match existing paint. components: Outside air film (R= .17), wood sheathing (R = 1.0), insulation (R = 14), gypsum board (R = .6), and inside air film (R = .68). Total R value is 16.45. U = .061. UA= 16.77. Insulate walls from inside by drilling holes every 16 inches between studs, blow in fiberglass insulation to achieve R-14 in stud cavity, fiberglass blown in insulation R-4 to the inch, 3.5 inch Sum of the designed UA is 5.83 plus 16.77 or a total of 22.60, compared with a total required UA value of 21.64. cavity. Spackle holes, repaint as necessary to match existing paint. Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly CONCLUSION : Code requirements are met by the designed insulation with UA values close between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation enough for compliance. in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of% inch plywood or similar material. New door shall be weatherstripped according to R-402.2.4 of NYS Energy Conservation Construction Code. Table R-402.1.2 of NYS Energy Conservation Construction Code requires R-20 or 13+5. What this means is R-13 cavity insulation and R-5 continuous insulation. Table R-402.1.2 requires R- 19 floor insulation in crawl spaces. Because the code can not be met just by insulation of the stud cavities, a trade off will be largely met by installing more insulation under the floor to offset the inadequacy of the blown in stud insulation. ✓r Area of floor from Sheet A-101 is 188 square feet. Area of walls from Sheet A-101 is 275 square feet after subtracting the area of windows and doors. �w UA is the product of the u value (1/R) and the area of the walls or floors. SSS UA required by code: To simplify calculations, units will be left out of final calculations. 3 f Floors: 1/19 BTU/hr-deg x 188 square feet = 9.89 _ Walls: 1/20 BTU/hr-deg x 275 square feet = 13.75 DANIEL, KARPEN Total UA value is 21.64 � n 1� �V m b111�� L�j 1/e PROFESSIONAL ENG:NIZER oz CtsINSuL:I'A1v T,R. I Building Inspections 7% • UA as designed: For floors the total R value is the sum of the various floor components: oak �C�GdG //�-�' Energy Conservation Consulting g P •Full Spectrum Polarized Lighting j flooring (R = .70), pine subfloor (R = 1.0), insulation (R= 30), and gypsum board (R = .6). Total R �j'� l�jb��� _Z �1 c� Environmental Conservation •Expert Testimony value is 32.3. U = .031. UA = .031 x 188 = 5.83. Patents and Inventions 3 Harbor Hill Drive•Huntington,New York 11743 (�Y ; www.danielkarpen.com (631)427-0723 EXISTING HOUSE NO CHANGES _ CLOSET CLOSET o, OR 11,_6„ 12 -52„ CO OF PORCH CONVERTED TO HABITABLE SPACE C� u0. F— X � r L z 1 W co \ x � UJ k a" R4 �C_a_ DANIEL KA"PEN PLAN M.Jt 0 � �V a RAO ______ S : S �t+_� ° Building Inspections r o o -�'f f� ® Energy Conservation Consulting / 2 - — ® ����"�U L ' °all Spectrum Polarized Lighting j2. °i✓iiv,ronmental Conservation d y / -6 3"��'1 °Expert Testimony T I ° Patents and Inventions 3 Harbor Hill Drive°Huntington,New York 11.743 JF www.danielk en.com �J arp (631) 427-0723 ENERGY NOTES Work to be done: Insulate attic, walls, floor, and install new door'to crawl space. Insulate attic by drilling holes in ceiling every 16 inches between rafters, blow in fiberglass insulation to achieve R-49 required by Table R-402.1.2 of NYS Energy Conservation Construction 'UA as designed: For walls, the total R value is the total of the sum of the various wall . components: Outside air film (R= .17), wood sheathing (R = 1.0), insulation (R = 14), gypsum Code (climate zone 4). Spackle holes, repaint as necessary to match existing paint. board (R = .6), and inside air film (R = .68). Total R value is 16.45. U = .061. UA = 16.77. Insulate walls from inside by drilling holes every 16'inches between studs, blow in fiberglass insulation to achieve R-14 in stud cavity, fiberglass blown in insulation R-4 to the inch, 3.5 inch Sum of the designed UA is 5.83 plus 16.77 or a total of 22.60, compared with a total required cavity. Spackle holes, repaint as necessary to match existing paint. UA value of 21.64. Insulate crawl space by installing 6 inch thick blue Styrofoam insulation cut to fit snugly CONCLUSION : Code requirements are met by the designed insulation with UA values close between floor beams against bottom of subfloor. R value of insulation is R-30. Hold insulation enough for compliance. in place with caulking along bottom edge of insulation against floor beams. Protect insulation by installing mold resistant gypsum board against bottom of floor beams. Install new door to crawl space of% inch plywood or similar material. New door shall be weatherstripped according to R-402.2.4 of NYS Energy Conservation Construction Code. Table R-402.1.2 of NYS Energy Conservation Construction Code requires R-20 or 13+5. What this means is R-13 cavity insulation and R-5 continuous insulation. Table R-402.1.2 requires R- 19 floor insulation in crawl spaces. Because the code can not be met just by insulation of the stud cavities, a trade off will be largely met by installing more insulation under the floor to offset the inadequacy of the blown .P...® in stud insulation. OF C3�p'� �• Area of floor from Sheet A-101 is 188 square feet. Area of walls from Sheet A-101 is 275 square feet after subtracting the area of windows and doors. UA is the product of the u value (1/11) and the area of the walls or floors. ' ..,cgs UA required by code: To simplify calculations, units will be left out of final calculations. Floors: 1/19 BTU/hr-deg x 188 square feet =9.89 Walls: 1/20 BTU/hr-deg x 275 square feet = 13.75 a-M4 DANIEL KAIPEN Total UA value is 21.64 (J1 ��M d�L,1 PROFESSIONAL NGEEx %t IlSut I'A1Vi',I? .. . •Building Inspections UA as designed: For floors the total R value is the sum of the various floor components: oak �(�GJjG [� / •Energy Conservation Consulting g � P / � •Full Spectrum Polarized Lighting - flooring (R = .70), pine subfloor (R = 1.0), insulation (R= 30), and gypsum board (R = .6). Total R �'C l�b,®6� d Z 1 g Environmental Conservation ®Expert Testimony value is 32.3. U = .031. UA = .031 x 188 = 5.83. -Patents and Inventions 3 Harbor Hill Drive•Huntington,New York 11743 Y ; www.danielkarpen.com (631) 427-0723