HomeMy WebLinkAbout47106-Z � g11Ef0i G� Town of Southold 6/11/2022
a yes?? P.O.Box 1179
y 1} 53095 Main Rd
T•
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43143 Date: 6/11/2022
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 1300 Lake Dr., Southold
SCTM#: 473889 Sec/Block/Lot: 59.-1-21.9
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
10/29/2021 pursuant to which Building Permit No. 47106 dated 11/10/2021
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof-mounted solar panels on existing single-family dwelling as applied for.
The certificate is issued to Mazzanobile,Gregory&Beatrice
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 47106 5/25/2022
PLUMBERS CERTIFICATION DATED
Ohod Signature
TOWN OF SOUTHOLD
��o�SUFFnt��oG
y BUILDING DEPARTMENT
H z TOWN CLERK'S OFFICE
"oy .
A?� SOUTHOLD, NY
ISO
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 47106 Date: 11/10/2021
Permission is hereby granted to:
' Mazzanobile, Gregory
184 Warren St Apt 2
Brooklyn, NY 11201
To: install roof-mounted solar panels on existing single-family dwelling as applied for with.
flood permit.
At premises located at:
1300 Lake Dr., Southold
SCTM #473889
Sec/Block/Lot# 59.4-21.9
Pursuant to application dated 10/29/2021 and approved by the Building Inspector.
To expire on 5/12/2023.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO-ALTERATION TO DWELLING $50.00
Flood Permit $100.00
Total: $300.00
Building Inspector
oF so�ryol
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 A Q sean.devlin(-town.southold.ny.us
Southold,NY 11971-0959
�yCOUNTV,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Gregory Mazzanobile
Address: 1300 Lake Dr city:Southold st: NY zip: 11971
Building Permit#: 47106 Section: 59 Block: 1 Lot: 21.9
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Harvest Power LLC License No: 54016ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Solar X
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks
Disconnect L�l Switches 4'LED Exit Fixtures Pump
Other Equipment: 7.4kW Roof Mounted PV Solar Energy System w/ (20) REC370AA Modules,
IQ3 Combiner w/220x2 210x1, 40A Fused AC Disconnect
Notes: Solar
Inspector Signature: Date: May 25, 2022
S. Devlin-Cert Electrical Compliance Form
Isf s L) -7 ' (9( r3 d L-eike T,.--
TOWN
OF SOUTHOLD BUILDINGDEPT.
ao _
765-1802
INSPECTION
[ ] FOUNDATION 1ST- [ ] ROUGH PLBG.
[ ] FOUNDATION.2ND ` [ _ ] . INSULATIOWCAULKING
[ ] FRAMING/STRAPPING [ ] FINAL ,
[
]-- FIREPLACE &-CHIMNEY` [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) NA ELECTRICAL (FINAL)
[ ] CODE VIOLATION _[ ]' PRE C/O
REMARKS:400000ae
v�r
J4
nn �.
&;,Vep
0?�OVAJ
DATE Z Z?i INSPECTOR
�o�*Of SOUT,yo�
; jou # # TOWWOF: SOUTHOLD BUILDING DEPT.
`yc0urm��'
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ : ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL S®�
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
REMARKS
TN-x/ C> /C. Fcr_ 0
DATE q—1INSPECTOR _�-- -
Graham Associates 256 Orinco Drive, Brightwaters,NY 11718
Building Consultants& Expeditors (516)665-9619 Fax(516)969-0115
March 1,2022
Town of Southold t ' U V is
Building Department
Town Hall Annex ( J
P.O. Box 1179 MAR - 3 2022 l�/
Southold, NY 11971
esti `11-
Re: Mazzanobile Residence—1300 Lake Drive,Southold, NY 11971
SCTM#1000-59.-1-21.9
Permit No.47106—7.4 kW Rooftop Solar Photovoltaic System
To Whom It May Concern,
Please be advised that I have inspected the solar roof array at 1300 Lake Drive,Southold, NY 11971
and have determined that it has been performed in accordance with the manufacturer's
recommendations, and the approved building permit.The installation meets the 2020 NYS Building
Code,2018 International Code, and ASCE 7-16.
If you have any further questions, do not hesitate to call.
Si � � @�
��\�\GNp E L pjtC�
Mazzanobile Residence— Permit#47106
1300 Lake Dr, Southold, NY 11971
SCTM# 1000-059-01-021.9
Electrical Work Correction Photos:
�, rr
III
tJg-
'Yx
TR40R �.
Y1027063
250V AG
acu,Y T �
40A
Z5OV Ac
t
fl�Nl�
u
j
w
srA°,
sf
FIELD:INSPECTION REPORT. DATE. . COMMENTS
FOUNDATION.(1ST):
FOUNDATION(2ND.),.
�z
�O
y V
ROUGH FRAMING:
PLUMBING: .
r
INSULATION.PER.N.Y.
STATE ENERGY CODE
FINAL
ADDITIONAL CO ENTS
I'C'J+ i I 01 'W
x
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone(631) 765-1802 Fax(631)765-9502 fts://,w.ww.sotiiholdi6mi,6�jgov;
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only D EC EH E
PERMIT NO. Building Inspector: OCT 2 9 2021
Applications and forms must be filled out in their entirety.Incomplete. BUILDING DEPT
applications will not be accepted.
ptpd. Where the Applicant Is not the owner,an TOWN OF SOUTHOLD
Owner's Authorization form(Page 2)shallbe completed.
Date:
/L
OWN-tR(S)OF iROP16111TY.-
Name:GWCA VAIIZ.Zannb.k, SCTM#1000- al . Ct
Project Address: t500
Phone#: 6D
rl•Cl
Mailing Address:k 0 0 L
CONTACT PERSON:
Name: Mat---
Mailing Address: 2941 Sunrise Hwy, -Islip Terrace, NY 11752
Phone#: (631) 647-3402
DESIGN PROFESSIONAL INFORMATION:
Name: Michael Dunn, R.A.
Mailing Address: 1981 Union Blvd, Bay Shore, NY 11706
Phone#: (631) 665-9619 Email: Bayblueprint@aol .com
CONTRACTOR INFORMATION:
Name: Harvest Power LLC
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email-.'
DESCRIPTION OF PROPOSED CONSTRUCTION,
[INewStructure ElAddition ®Alteration EIRepair ElDernolit ion Estimated Cost of Project:
;Kother�C&.,r 000 CQ
Will the lot be re-graded? CYes ®No Will excess fill be removed from premises? E]Yes El NO
PROPERTY INFORMATION
Existing use of property: Residence Intended use of property: (no change)
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
�1.eSick'.o.� this property? ❑Yes ®No IF YES, PROVIDE A COPY.
Cheek Box After Reading: The owner/contractor/desien professional is responsible for all;drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with Al applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law,
Application Submitted By(print name): [Authorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTYOF
being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief-and
that the work will be performed in the manner set forth in the application file therewith. NICHOLAS P CAPUANO
NOTARY PUBLIC-STATE OF NEW YOR
Sworn before me this Ne.01CAS367793
Qualified in Suffolk County
13 day of 0--t ber ..20 ,1 P(Jwy Commission Expires 11-27-2021
Notary Public
P_,RO.PERT__Y_.OWNER-AUTHORIZA T-IOIV_-
- ere a-app Ivan is no e-owner — -- —
I, C- -?A N�AZZC3�hbb��C residing at ACD Ldte`7U-. SaukYvA6
do hereby authorize Mmemix wke al I I��k 4C10or to apply on
my behalf to th wn of Southold Building Department for approval as descr'bed herein.
o �3 2 1
Qui:,,i� ' u, r t
C Q �-- V` U
2
I.
i
P
E
y�
{ Building Department Annlication
4 A,UTHOMATI®N
(Where the Applicant is not the Owner)
1, 27,Qm\2 \g, residing at NaS-X�) LQY K:
(Prih4roperly owner's nanie) (Mailing Address)
do hereby authorize 7Cbp W Ce
(Agent)
Harvest Power LLC to apply on my behalf to the.
Southold Building Department.
{
CONSENT TO INSPECTION
s
i
4
i
f
{ Ars' `�0►'ZZQ�CIO���� ,the undersigned,do(es)hereby state:
Owner(s)Name(s)
That the undersigned(is)(are)the owner(s)of the premises in the Town of
Southold, located at LI&Ch !_ 1Le_ `7'C S G`1W1G kd
{ which is shown and designated on the Suffolk County Tax Map as District 1000,
i Section 5 ct , Block�_, Lot 2,�• Q
That the undersigned (has)(have)filed, or cause to be filed,an application in the
Southold Town Building Inspector's Office for the following:
j
W1240 CECS770 PAR QuS k!` a)Akd 9gkkz
{ That the undersigned do(es)hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon,to conduct such inspections as they may deem necessary with
respect to the aforesaid application, including inspections to determine that said premises
comply with all of the laws,ordinances,rules and regulations of the Town of Southold.
The undersigned, in consenting to such inspections;do(es)so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws, ordinances, rules or
regulations of the Town of Southold_
Ck
r_igrtature)�
o911 R N
d�o�°S°fFoi��o TOWN OF SOUTHOLD—BUILDING DEPARTMEN ® H E H
o G Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 1 095ROv 1 8 2021
Telephone (631) 765-1802 https://www.southoldtownny.ao
' BUILDING DEPT.
TOWN OF SOUTHOLD
Floodplain Development Permit Application
-[ -PROPERTY INFORMATION: Flood Zone: �� XFIRM Panel: STM
#1000- 5-9, ' Z(.
Address: tion L-A VG L>r- q
City: 0-L'4 f'rl r) Zip: 1 1
CONTACT,PERSON: Name: fo all I j Jil f TPhone#: �"61 -b q'7..
Mailing Address: Zq 4) SLA-4-NAw-i,
PROJECT DESCRIPTION: -ih5+'U Pr 1,40 p\I
(1Z 3-1 DAF, FO69DP fV0A,f o. kkS .
SECTI'OWA:STRUCTURAL DEVELOPMENT(.CHECK ALL THAT APPLY');
Type of Structure Type of Structural,Activity
Residential(1 to 4 families) ❑New structure
❑ Residential(more than 4 families) ❑ Demolition of existing structure
❑ Combined use ❑Replacement of existing structure
❑Non-residential ❑Relocation of existing structure
❑ Elevated 9 Addition to existing structure
❑ Flood proofed(attach certification) ❑Alteration to existing structure
❑ Manufactured Home ❑ Other:
❑ Located on individual lot
❑ Located in manufactured home park
SECTION.B:.OTH ER DEVELOPMENT(CHECK ALL THAT APPLY)
❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging
'0 Connection to public utilities or services ❑ Paving ❑ Placement of fill material
❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction
❑ Fence or wall construction ❑ Watercourse alteration (attach description)
❑ Excavation (not related to a structured development) ❑Other development not listed (specify):
By signing below Ii agree to the terms and,conditions of this permit and certify to the best of my knowledge the information contained,
in this application is true,and accurate:'I,understand that no work.may start until a permit is issued.The permit may be revokedif any
false statements are made herein.If revoked,all work must cease:until permit is re-issued. Development shall not be used or occupied
'until'a Cert.of.Compliance is issued.The permit will expire.if nomork is commenced within one year of issuance.Other permits may be
required to fulfill:regulatory requirements.Applicant gives consent to.focal'authority or representative to make reasonable inspections
to verify compliance.,
Application Submitted By(print name):
Signature of Applicant----'—' Date:
f
I
I
I
I WING DEPARTMENT- Electrical Inspector
LjIAnnex
TOWN OF SOUTHOLD
OCT 2 9 20T7own - 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
• BUILDING DEPT.
o� TOWN of souTHoTjplephone (631) 765-1802 - FAX (631) 765-9502
rogerr(c southofdtownny.gov — seandAsoutholdtownny.gov
i
APPLICATION FOR ELECTRICAL INSPECTION
i
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: Harvest Power LLC
Name: John D'Aries/Fulton Electric Inc .
License No.: 54016-ME email: kfriend@harvestpower.net
Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone No.: (631) 647-3402
JOB SITE INFORMATION (All Information Required)
Name: M 2Z
Address: %Sc)& LgtC r'
Cross Street:
Phone No.:
Bldg.Permit#: �� b email:
Tax Map, District: 1000 Section: Sq,' Block: \ Lot.
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Installation of a3kW Solar PV System w/ (20) &/7-- IMA—
Installation
Panels
Circle All That Apply:
Is job ready for inspection?: Y9 NO Rough In Final
Do you need a Temp Certificate?: (2ESl NO Issued On
Temp Information' (All information required)
�e
Sizt1y 3 Ph Size:. 15'ZI A #Meters�_ Old Meter#
New Service)Fire Reconnect- Flood Reconnect- Service Reconnected - Underground) �Overhea
, nderground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
Request for Inspection Form.xls
111 \
f
�DSu�FpC�.�O BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
o Town Hall Annex - 54375 Main Road - PO Box 1179
y - Southold, New York 11971-0959
%S5
�bp��. Telephone (631) 765-1802 FAX (631) 765-9502
rogerr(aD-southoldtownny.gov sea nd(cDsoutholdtownny.ciov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: TTZ67r2i1__
Company Name: Harvest Power LLC
Name: John D'Aries/Fulton Electric Inc.
License No.: 54016-ME email: kfriend@harvestpower.net
Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone No.: (631) 647-3402
JOB SITE INFORMATION (All Information Required)
Name: Gregory Mazzanobile
Address: 1300 Lake Drive Southold NY 11971
Cross Street: West Drive
Phone No.: 347 306-7851
Bldg.Permit#: 47106 email: gregmazzanobile@gmail.com
Tax Map District: 1000 Section: 059 Block: o1 Lot 021.009
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Installation of. a 7 . 4 kW Solar PV System w/ (20) REC370AA
Roof-Mounted Panels
Circle All That Apply:
Is job ready for inspection?: YE NO Rough In- Finaf
Do you need a Temp Certificate?: YES LN Issued On
Temp Information: (All information required),
Service Siz 1 Ph 3 Ph Size: 150 A #Meters 1 Old Meter#
ew Servic Ire Re onnect- Flood Reconnect- Service Reconnected - Underground - Overhead
derground Laterals 1 2 H Frame Pole Work.done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
Request for Inspection Form.xls
PERMIT # Address:
Switches
Outlets
G F I's
Surface
Sconces
H H's
UC Lts
Fans Fridge HW
Exhaust Oven W/D
Smokes DW Mini
Carbon Micro Generator
Combo Cooktop Transfer
AC AH Hood Service
Amps Have Used
Special:
Comments `'�- D G/a- • '�
Q
1
HARVESTH3
POWE R
Harvest Power LLC 1 2941 Sunrise Hwy., Islip Terrace, NY 11752 1 Office: 631-647-3402 1 Fax: 631-647-3404
March 2,2022 ® E C F U y 2
MAS n. ,� A22Town of Southold
Building Department TOWN"WIDING DEPT.
P.O. Box 1179 UTHOLD
Southold,NY 11971
Re: Engineer's Post-Install Letter&Final Electrical Inspection Application
Mazzanobile Residence— 1300 Lake Drive, Southold—BP#47106
Dear Town of Southold Building Department:
Enclosed,please find the Engineer's post-install letter and electrical inspection
application for the PV solar installation completed at the above referenced residence.
The homeowner will follow up to schedule the final electrical and building inspections.
Thank you for your attention to this matter. If you need any further information, please
contact me at(631)647-3402 or via email at.jott@harveStDower.net.
Very truly yours,
J ie Ott
Licensed, insured & bonded I License # Nassau County: H0811250000 1 License # Suffolk County: 48165-H
Bunch, Connie
From: syarbrough@harvestpower.net
Sent: Wednesday, May 25, 2022 4:39 PM
To: Bunch, Connie
Cc: 'Julie Ott'
Subject: Mazzanobile Inspection Correction Photos
Attachments: Mazzanobile Wire Correction Photos FINAL_5.25.22.pdf
Please see attached photosheet for 1300 Lake Dr,Southold, BP#47106
Mr. Mazzanobile's install failed the final electrical inspection due to several electrical issues on 3/29/22. We completed
the service to correct the issues listed on the inspection report& have photos of the corrections.
Thanks,
s6waly
Sarah Yarbrough
Permit Coordinator
syarbrough @ harvestpower.net
harvestpowersolar.corn
office: 631-647-3402 1 fax: 631-647-3404
Ext. 304
2941 Sunrise Highway
1. Islip Terrace, NY 11752
This email is confidential and may contain legally privileged information. If you are not an intended addressee,you must not disclose,copy,distribute or take any
action in reliance upon this email. Any calculated cost,benefit,economic,and performance data in this email are estimated values for illustration only and do not
represent a guarantee by or contract with Harvest Power LLC
ATTENTION: This email came from an external source. Do not open attachments or click on links from
unknown senders or unexpected emails.
i
R Suffolk County Dept of
'a a. Labor, Licensing&Consumer Affair
HOME IMPROVEMENT LICENSE }
Name fI
CARLOS LANZA
Business Name
This certifies that the I.
bearer is duly licensed Harvest power LLC
by the County of suffolk
License Number:H-48165
Rosalie Drago Issued: 11/18/2010
Commissioner Expires: 11/01/2022
Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706
Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115
October 17, 2021
Town of Southold
Building Department
54375 Rt. 25
Southold, NY 11971
Re: Mazzanobile Residence
1300 Lake Drive
Southold, NY 11971
7.40 kWDC, 5.80 kWAC Rooftop Solar Photovoltaic Systems
To Whom It May Concern,
Please be advised that I have analyzed the existing roof structure at the
above-mentioned premises and have determined that it is adequate to
support the additional load of the solar panels and a 140 mph wind load
without overstress, in accordance with the following:
The 2020 New York State Uniform Fire Prevention and Residential Building
Code; Town of Southold Local Code, Long Island Unified Solar Permit
Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020
National Electric Code including ASCE7-10
If you have any further questions, do not hesitate to call.
C H
DUNK
Cj
Michael unn, RA
�y f;
Y
k �
r
MOST"TRUSTED `
PA
'ti•�Ft�T �
y
d
1 Y " `t751
yy1[<M1 �ry q4
Y.w
PRiJorcr EXPERIENCE
375
�Y y
D 25 YEAR �s,
WP
POWER
ELIGIBLE FOR PERFORMANCE
-,MEN
1 721+2.5[67.75±0.11
,213[1.1] 802[31.S] 455[17.9] CERTIFICATIONS
IEC 61215:2016,IEC 61730:2016,UL 1703,UL 61730
❑ + I IEC 62804 PID.
1000(391 IEC 61701 S a I tMIst
IEC 15,2716 .Ammonia.Resistance
- . .
1SO11925-2 Ignitability(Class E)
..........
IEC,62782 Dynamic'Mechanicat Load,
o +1 IEC 61215-2:2016 -Hailstone(35mm)
+1 i
AS4040.2 NCC 2016 Cyclic Wind Load
+1 .......
ISO 14001:2004,ISO 9001:201S,OHSAS 18001:2007,IEC 62941
_H
+1
11±0.2 take0way
6 1.,.,
t,kyWEEE,p[i
Iq _yclinp&
[0.43±0.81, w1A® C E EO
7 1!WARRANTY*
[0.78±0.08]17) 12001471 Standard REC ProTrust
Installed by an REC Certified I
's
Solar Professional Nor Yes. Ye
621 System Size All 425kW 25-500 kW
45[1.S] 22.5[0.91 --'±3[24.5±0.121 ................
7 Product Warranty(yrs) 20. 25 25
AL
30[1.18] -
Power uw'el Warranty rsd) 2..............<..,._--._,S 2S 2 5..
Measurements in mm tin) _............_....._.:_:__.....I
Labor Warranty(yrs) 0 2S 10
GENERALDATA Power in Year 1 98% 98% 98%
-------------................
120 haif-cut cells with REC iAnnual Degradation 0.259/6 0:25% 025%
St5ubIiMC4 PVKBT4/KST4(4mni i
Celitype: heterojuncticin cell technology Connectors: in accordance with IEC 62852 t Power in Year 25 92%' 92% 92%
6stfings cf20 cells in series j IP68 only when connected i See warranty docu nent-s f-o-ri-d'e-t--ai-is.-C-onditions-a-pi
......... ...............
----------
3.2 mm solar glass,with' . 4ri
Glass: ) Cable: solar cable,1.0 ri
anti-refleittion surface treatment j inaccordance,wtthENS0618 ?MAXIMUMRATINGS
_...............
........ ....... ..................
Operational temperature: 40...+85°C
Highly resistant
Backsheet: Dimensions: 1721x1016xkmm(1.75m1) .........................................
polymericc6irstruction(bla&)'i Maximum system voltage: 1000V
................ ..................... ........
F rame: 'Design load(+):,snow 4.666Pa(47Skg/m2)'I
Arad lied atuminurn(black)-I Weight: 19.15 kg
.................. Maximum test load(+): 7000Pa(713kg/m')*
Junction box: 3-piart,3 bypass diodes,IP67rated I
inaccordancewith IEC62790: Origin: Made in Singapore Design load(-):wind 2666 Pa(272 kg/ri
Maximum test load'(-): 4000 Pa(407 kg/ri
ELECTRICAL DATA Product Code*:RECxxxAA Black MaxseriesTuse rating: 2SA.,;
.......... .......
Maxreverse c4rent: 25A
Power 0UtPUt_�mA-,(WP) 355 360 365 370 375, _�uslng"safet-ifactoroh.5
......- -...... . ...................... . .......... acuate te a
Watt Class Sorting-(W) -0/+S -0/+S -0/+5 -O/t5 -0/+5 'See installationcmaanual for mounting instructions
.............. ......
Nominal PowerVoltage-Vi,,(V) 36.4 36:7 373� 37.4 7.8
.................... ....................... .......... 41 TEMPERATURE RATINGS-
U Nominal Power Current-1 (A) 9.77 9.82 9.8S 9.9. 9.94
I.. .................
Ln ........... _....MPP......................-...... ..................................... ........................... Nominal Module OperatingTemperature: 44'C(±2'C)
Open Circuit Voltage-Vcc(V) 416 43.9 44.0 44.1 442 ......... .......
........... .................................. ................................ ............. ..........�1.+_n IiA
Temperature coefficient ofP,,,: -0.26%/'C
Short Circuit Current-l5c(A) 10.47 10.49 10.52 10.55 10,58 -------- .2
.................-............ ........... .......... ............. Temperature coefficient ofVoc: • -0.24%/.-C Y
Power Density(W/ni 202.85 205.71 208.57 211.42 21428
.................... ............... ........... .......... - Temperature coefficient of Isc: 0.04%/0C iK
Panel Efficiency(%) 20.3 20.6 20.9 212 21.4 'The temperature coefficients stated are linear values
Power 0.u t p u.t..--P (W.p) 271 274- ... ... 2.78 282, 286 LOW LIGHT BEHAVIOUR
Nominal Power Voltage-V,(V) 34.3 34.6 3S.0 35.2 35-6 Typical low irradiance performance ofmodule atSTC:
0 ....................... ................... I I
2 Nominal Power Current.)MPP Impi,(A) 7,.89 7.93 7.96 &00 8.03 _e-_--------- I t
---------
Z ............ ................ ...........
Open Circuit Voltage-Voc(V) 413 414 41.5 4Z6 416 of
........... .......... .2
Short Circuit Current-Isc(A) 8.46 8.47 8.50 8:52 8.55 w
-------------
Values at standard test conditions(STC:air mass AM I.S,irradiance 1000 W/ri temperature 25'Q,based an a production spread with
a tolerance ofP_,V,,&1,,i3%within onewait class.Nominal module operating Lempera Lure(NMOT:air mass AM 1.5,irradiance
800 W/ri temperature 20'C,windspeed I m/s).*Where xxx indicates the nominal power class(Pi at STC above. m irradirradiance(W/m')'
solar ene,., &-ated to empowering
energy,transition,
swish,leading high quality,
I e ed in'Norway in 1996,r
41STR pa el s p oily of 1 W�WIW6
'a
!14;
i5
rata Sheet
Enphase Microinverters
Region:US
Enphase The high-powered smart grid-ready
p Enphase IQ 7 MicroTM and Enphase IQ 7+ MicroTM
IQ7 and �Q 7+ dramatically simplify the installation'processwhile
�{ �{ achieving the highest system efficiency.
M icroi everters Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate seamlessly with
the Enphase IQ EnvoyTM, Enphase Q Aggregator TM,
Enphase IQ BatteryT", and the Enphase Enlighten TI
monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
• Lightweight and simple
• Faster installation with improved,lighter two-wire cabling
• Built-in rapid shutdown compliant(NEC 2014&2017)
1 Productive and Reliable
• Optimized for high powered 60-cell and 72-cell*modules
• More than a million hours of testing
• Class II double-insulated enclosure
• UL listed
0
Smart Grid Ready
• Complies with advanced grid support,voltage and
frequency ride-through requirements
" Remotely updates to respond to changing
grid requirements
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
U *The IQ 7+Micro is required to support 72-cell modules.
L -
ENPH
AS E°
To learn more about Enphase offerings,visit enphase.com V
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235W-350W+ 235W-440 W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48V 60 V
Peak power tracking voltage 27V-37V 27V-45V
Operating range 16V-4 8 V 16 V-60 V
Min/Max start voltage 22V/48V 22 V/60 V
Max DC short circuit current(module Isc) 15 A -15A
Overvoltage class DC port II II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L Q voltage/rangez 240 V/ 208 V/ 240 v/ 208 V/
211-264 V 183-229V 211-264 V 183-229 V
Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
-- -- - -- - ---- -- - ----- - ---- --- - - — -- -- - -5.8-Arms
-- — -- - -- - -- - - -- - -
AC short circuit fault current over 3 cycles 5.8 Arms
Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(240 VAC)
13(208 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed current 0 A 0 A
- -- - - - ----- - - - -- - - --- - -- - - - -- - - -- -- - -- - - - - -- --
Power factor Setting 1.0 1.0
Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak CEC efficiency 97.6% 97.6%_ 97.5% 97.3%
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
MECHANICAL DATA IQ 7 Microinverter
Ambient temperature range -40°C to+65°C
Relative humidity range 40%to 100%(condensing)
Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08 kg(2.38 lbs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at https://enphaEe.com/en-us/support/module-compatibility.
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com E N P H AS E
:�2018 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc
2018-02-08
` r
a
T d
PHOTOVOLTAIC ' ROOF MOUNT SYSTEM
20 MODULES-ROOF MOUNTED - 7.40 kWDC, 5.80 kWAC
1300 LAKE DR, SOUTHOLD, NY 11971 USA HARVESTP(D E
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
SYSTEM SUMMARY: SHEET INDEX TERRACE,NY 11752
GOVERNING CODES: TEL:(801)989-3585
(N)20-REC SOLAR REC370AA(370W)MODULES 2017 NATIONAL ELECTRICAL CODE(NEC) PV-0 COVER SHEET website_ owernet
2020 NEWYORK STATE UNIFORM PV_1 SITE PLAN WITH
(N)20-ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS 2020 NEW YORK STATE RESIDENTIAOL DE CODE PV-2 ATTACHMENT DETAIOLSP�N G 10K!Dv, l
(N)JUNCTION BOX
(E)150A MAIN SERVICE PANEL WITH(E) 150A MAIN BREAKER PV-3 SINGLE LINE DIAGRAM �v 4 ,� T
(N)60A FUSED AC DISCONNECT PV-4 PLACARDS&WARNING LABELS
(N)ENPHASE IQ COMBINER BOX PV-5 ADDITIONAL NOTES
e,.
PV-6+ SPEC SHEETS = ,t "
DESIGN CRITERIA:
ROOF TYPE:-ASPHALT SHINGLE O
VELZST£i
NUMBER OF LAYERS:-1 , DE '�i7) `, REV.
ROOF CONDITION:GOOD J
ROOF FRAME:-2"X10" RAFTERS @16"O.C. BLDG.PER /2021 0
STORY:-TWO STORY OCT 2 9 2021 ID
SNOW LOAD:-25 PSF
WIND SPEED:-130 MPH BUILDING DEPT.
WIND EXPOSURE:-B TOWN OF SOUTHOLD
GENERAL NOTES: �g
1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS. ARRAY L CATIONS :" W, 4` - M_ I �� 6d'+ 4
2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION 0 ro• = _ « "
,i PROJECT SITE ,
AND CERTIFY COMPLIANCE. ~s w ;} lit-
3.
PROJECT TO BE INSTALLED WITH CODE COMPLIANT
RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT PROJECT NAME
SYSTEM. -
4.
YSTEM.4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN.
r
5. HARVEST POWER, LLC.,THE SOLAR INSTALLATION �_ Win
Aq.
CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL �r � �r W
RELATED REQUIREMENTS OF THE GOVERNING r _ I if�f^ I! ~ O
MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY (' J F_
AHJ'S. O
6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC ` s•
K � p W � O
. s" '4f- ,` ..ks - ""gd 4"'xr>, . :k` ' r W 0
cl) CD
REQUIREMENTS INCLUDING ARTICLE 690 SOLAR � � ` `' �' ''' ;'. ' Y Z O
lla
PHOTOVOLTAIC PV SYSTEMS. F >k;„ ,, r; ;rt" ._ O LL.
o
7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER ,r _ 1 ` I`t-" " ;: 4fi ' s J J O O
OF ROOF COVERING IN ADDITION TO THE SOLAR ;
EQUIPMENT. x '. T Q p = O
F .� O J
8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL � As vin = ,* , ., N r- O �.
TO AND NO MORE THAN 6.5"ABOVE ROOF - '' r _ Lt'=•;. t = r F-
9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE
" { t � (�
AND ATONE GABLE EAVE. sem:_..; �' : ," Z 9N =
10. THIS DESIGN COMPLIES WITH 130 MPH WIND "" '
REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S .I�
�� a mer_: b f 4
AND ASCE 7-16. wk -r,,... `'* `Nin
11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH ' ' ,� 9° ], ` '
ACCESS AND VENTILATION REQUIREMENTS OF THE �� �;"' "' inn F a SHEET NAME
UNIFORM CODE, HARVEST POWER PROPOSES THAT
ALTERNATIVE VENTILATION METHODS WILL BE COVER SHEET
EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE a6 = --
,-E , r� SHEET SIZE
DISCRETION OF THE MUNICIPALITY IN WHICH THIS :�^ -� �` '� '. '
DOCUMENT HAS BEEN FILED. _ _ , )L _ r �' " ANSI B
r � _ . s . 'mss,_.__________.___ _. �__...__J
12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW
YORK STATE UNIFORM FIRE PREVENTION AND 11" X 17"
RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP
SHEET NUMBER
PV-0 SCALE:NTS PV-0 SCALE:NTS �r PV_O
MODULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA:
NUMBER OF MODULES=20 MODULESSHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND �.
MODULE TYPE=REC SOLAR REC370AA(370W)MODULES `\ OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF
MODULE WEIGHT=43 LBS/19.5 KG. / \ BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT i
MODULE DIMENSIONS= 67.8"X 40.0"= 18.83 SF CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS.
UNIT WEIGHT OF ARRAY=2.28 PSF
`\-, HARVESTPOER
(E) CHIMNEY A VEST POWER LLC
� _-
\ ROOF#1 HIGHWAY ISLIP
(10) REC370AA(370W) 6�_ 11752
RAFTERS=2"X10"@16"O.0 Gj� 4``ebsi e. 6�r efc� 5wernet
/ 97O' 111'AZIMUTH, 30°TILT
cc s \ O V
gRfq `�\'°ROPER VERSION
DESCRIPTION DATE REV.
BLDG.PERMIT 10/15/2021 0
10
/
, ✓B PROJECT NAME
o
QO RO �c V �/ v LL r O b Z)
♦ r p }. o
OF
P\ gREgss ♦ ♦ `p u S J W Z OO U) O
OAF\�` ♦ ♦ a M m p LL
F \ ♦ / (N)JUNCTION BOX Z O 0 O Z>
/ O 2 O J
(N) 3/4"EMT CONDUIT =) O ? 0
/ RUN 1/2"ABOVE ROOF I_—
\ \ �1gROOS (E) 150A MAIN SERVICE PANEL Z =
/ WITH (E) 150A MAIN BREAKER Q
(INSIDE)
ROOF#2 / 3 (E) UTILITY METER
(10) REC370AA(370W) \ C)
RAFTERS=2"X10"@16"O.0 (N)60A FUSED AC DISCONNECT SHEET NAME
201°AZIMUTH, 30°TILT (20) ENPHASE \� / (N) ENPHASE IQ COMBINER BOX
IQ7PLUS-72-2-US \ ROOF PLAN
MICRO-INVERTERS \ SHEET SIZE
ANSI B
11" X 17"
SITE PLAN WITH ROOF PLAN ^ `��
1 SHEET NUMBER
pv_1
l �
(20) REC SOLAR REC370AA(370W) MODULES BILL OF MATERIALS
(20) ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION .
(02) BRANCHES OF 10 MODULES CONNECTED IN PARALLEL PER BRANCH SOLAR PV MODULE 20 REC SOLAR REC370AA(3701N)MODULES T `
INVERTER 20 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS H�
COMBINER BOX 1 ENPHASE IQ COMBINER BOX /f
SYSTEM SIZE:-20 x 370W=7.40 kWDC HARVESTPO FE[�
20 x 290VA=5.80 kWAC JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVEST POWER LLC
AC DISCONNECT 1 AC DISCONNECT 60A FUSED,WITH 40Al2P FUSES,240V NEMA 3R,UL LISTED 2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
TEL:(801)989-3585
harves owernet
K.
BI-DIRECTIONAL 2 n
UTILITY METER <
1-PHASE,3-W,120V/240V,60Hz tri sR:%FLu �-
!i- 02W O
�D IPI 1$L TE REV.
t 10/1512021 0
10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 L t
Ell I
SUPPLY TAP WITH
• • • JUNCTION TAP BOX
3/4"EMT CONDUIT RUN (N)12X12X6
(4)#10 AWG THWN-2 JUNCTION
(1)#8 AWG THWN-2 GND TAP BOX
(N)ENPHASE IQ 150A (E)150A MAIN
COMBINER BOX SERVICE PANEL
W/(E)150A
10 MICRO-INVERTERS IN BRANCH CIRCUIT#2 ENVOY MAIN BREAKER
j (N)JUNCTION BOX °° (N)AC DISCONNECT: (TOP FED) PROJECT NAME
60A FUSED,WITH 40A/2P
FUSES,240V NEMA-SR, r.
10A UL LISTED, '^ O Q
40Al2P FUSE W c:)
J
. • • O TV _ O
� 20A L ^ �
j 2 A
-------------
O W
-I--------- I-------------- I------� --- --- -- -C -- -- ---- ------{G� ------ ----- ------ — G ----------- - I w W zO Cp U)
LL
--------J m < p o
p _j -10) o
(3)#8 AWG THWN (3)#6 AWG THWN '�- Z C:) Lr) Z
(2)Q-CABLE (1)#8 AWG THWN GND (1)#8 AWG THWN GND EXISTING Q O = O J
(1)#6 BARE COPPER GND IN 3/4"EMT CONDUIT RUN IN 3/4"EMT CONDUIT RUN G SOUNDI G N , o j O
(20)ENPHASE IQ7PLUS-72-2-US I�
MICRO-INVERTERS a 0
Z =
TERMINATOR CAP ON LAST CABLE Q Q
CONNECTOR AC TRUNK CABLE(TYP)
SHEET NAME
SINGLE LINE
DIAGRAM
SHEET SIZE
ANSI B
11" X 17"
1 sINGLE LINE DIAGRAM SHEET NUMBER
SCALE: NTS PV-3
1
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED
COMBINER PANEL :LWITH RAPID SHUTDOWN
TERMINALS ON LINE AND LOAD DO NOT ADD LOADS HARVESTPO ER
SIDES MAY BE ENERGIZED IN _.___. _ HARVEST POWER LLC
THE OPEN POSITION LABEL LOCATION: 2941 SUNRISE HIGHWAY ISLIP
PHOTOVOLTAIC AC COMBINER(IF --- RACE,NY 11752
APPLICABLE). f 989-3585
LABEL LOCATION:
j Visite. f est owernef
INVERTER(S),AC DISCONNECT(S),AC 3" TURN RAPID SHUTDOWNI ��
COMBINER PANEL(IF APPLICABLE). SWITCH TO THE"OFF"
SOLAR ELECTRIC'
PV PANELS [�
POSMON TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY. " �� •3-L4&1. �.
p �1 0
• 29a -1
SION
SOLARFOR PV SYSTEM
DESCRIPTION DATE REV.
LABEL LOCATION: BLDG.PERMIT 1or15i2021 o
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED.
DISCONNECT IF REQUIRED BY LOCAL AHJ,OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
r AWARNI;NG
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
PROJECT NAME
OVERCURRENT DEVICE
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS w r o O
OCPD(IF APPLICABLE). N =
BUILDING SUPPLIED BY UTILITY CDCD
J
GRID AND PHOTOVOLTAIC i w z o U)ui o)
SYSTEM m Q o o ° LL
-
a � • • • ' p � .� rn O
ZoOo � z
-POWERSOURCE Q o = o
N MI- o � �
LABEL LOCATION: o ^J ::) O 0
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, (N)PV MODULES C) d Q
AT EACH TURN,ABOVE AND BELOW PENETRATIONS, C� Z
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. m D_ _
� Q
• . DISCONNECT
• (E)MAIN SERVICE PANEL
(INSIDE) SHEET NAME
MAXIMUM AC OPERATING AMPS' (E)UTILITY METER PLACARD &
NOMINAL VOLTAGE: , VAC (N)AC DISCONNECT WARNING LABELS
(N)ENPHASEIQ
COMBINER BOX SHEET SIZE
LABEL LOCATION:
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ANSI B
INTERCONNECTION. 11" X 17"
LABEL LOCATION: SHEET NUMBER
POINT OF INTERCONNECTION `/
(PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) P�/-4
' �la
1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER ff
MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND
METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVESTPOER
ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL 4suNRISEHIGHWAY ISLIP
GROUNDING ELECTRODE.
�� E NY 11752
�� ite, 89-3585
E�eksie.w vh8n� t ower.net
Q/
2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL
ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR
MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL
BE UV RESISTANT IF EXPOSED TO SUNLIGHT. IA
3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC "'- ERSION
CIRCUIT" OR EQUIV. EVERY 5 FT. DESCRIPTION DATE REV.
BLDG.PERMIT 10/15/2021 0
4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT
SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
VOLTAGE OPERATIONAL RANGE.
6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
PROJECT NAME
7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND
ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. W o
M N _ 2
8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL U o Ci
MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED u1 w O
SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE -� Y z o a �
ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 M < rn O
zC) 0= o z
9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT M � o - 3:
SUFFICE. O o O
U =
Q Q
SHEET NAME
ADDITIONAL NOTES
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-5
t
t
® HL.
HARVESTPP-0', fER
HARVEST POWER LLC
c c�c1 / . , y ` - �, ,• • 2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
C�CERTIFlCATIONS _y TEL:(801)989-3585
IEC 61215:2(116,IEC 61730:2016.UL 1708 UL 61730
website:www.harvestpower net
aj
v27t25(67.75±0.11 IEC 62804 PID _
w_r28[1.1] 802[315) 455(17.91
IEC61701
+ EC 62716 AmmoniaRes(stance / ti a NEL k.
❑ 1000[391 UL1703 Fire TypeClass2 �J
+ _ IEC62782 Dynamic Wchanical Load /
EC61215-2:2015 Hailstone(35mm)
_ -_- A540402NCC2016 Cyc(icWindLoad �
e-�a�•-�-6`]�mo7i�)
60]40012004,1509001:20I5,OHSA518001:2007,EC 629,11 tj ,__ ./.✓'t' i+
ire r ,
d e us 1.-
( ltoa (,1WARRANTY r�'�q R1f?�10tV 7E REV.
+ ,q[0.43:8D Q�.�....-.�^.�..�.-'-._�-- ____. ______-___
.�7r Standardi 'RECProTtust \ D r�tMJ 12021 0
1 1
htita!(edhyanRECCeltfied' r
F 205305 1 SolazProf oral No I Yes Yes
1200[471 - Sy'stemSae All f c25kW 25-506_kW
♦ ____ ProductWarrarrty(yrs) 20 1 25 25
22.5[0.9) 621x3 4.5x0.12) 'Power Warranty(yrs) 25 1 25 25
45[13] Labor Warrarity(yrs) 0 1 25 10
30[1.181 Power(nYearl 98% -98% 98%
Measurementsln mm(In)
GENERAL DATA - - _ Annual Degradation ' 025% 1 0.25% 0.25%
120 half-cutcellswithREC 5t5ub1iMC4PV-KBT4/K5T4,12AWG(4mm� PowerinYear25 92% I 92% 92%
Cell type heterojunct(oncell technology Connectors: tnaaordaricevAthIEC52852 5eewarrantydocumentsiordetailsConditlonsapply.
6itringsof20celi5flnseries IP58onlywheneonnected 'MAXIMUMRATINGS
0.13in(32mm)solarglasswith 12AWG(4mm°)PVwim,39+47in(1+12m)
Glass Cable Operationaltemperahae 40...+85'C
• ... _ r - - �
anti-reflection surface treatment aaardancevAed
th50618 _
- Highlyreslstant 678x40x1.2in(1721x1016x30mm)
Maximum system voltage: 1000V
Backsheet: construction Dimensions: .18.8.9 ft(1.75 ml) Design * snow - 4666Pa 97-Slbs s ft
polymeric_ _ _q (•_) g l k ( /q )' PROJECT NAME
Max)mum test io ad(+): 7000Pa 046 ms/sq ft)'
Frame: Anodized aluminum(black) Weight: - W-�----43lbs(195kg)
Design laad(-j:wind -- 2666 Pa(55.516s/sgft)'
CBJJunctlonbox:, - 3-part3_bypas-sdi�odes,IP67rat`ed__•� -__-: ~ Maximum test�test.._lo-a-.d_.._._-._.--_,..,..4.-_00P.^a_.8-35-T.h-s_.-ft)
Natcardan cewithlEC6250 Ori in MadeinSir$a ore
_$ 0 O
J
'Max series fuse rating: 25A W r O 0ELECTRICALDATA Product
Po•werOutpuP.a.(WMax reverse current: 25A r- N
360 365 _ -- • Calculated usingasafetytactorGf 5 VrC
'SeeinstallationmnualfoWatt Class Sorting-(W) -0/+S -0/+5 -0/+5 -0/+5 -0/+5 r mountm +nsWcian
r O
') REE
Nominal Power Voltage-Vr (V) 36.7 37.1 37.4 37.8 38.1 'tjEMPERATURERATINGS' W r w 0 ALPH (X
u Nominal Power Current-1,(A) 9.82 9.85 9.9 9.94 9.98 Nominal ModuleOperatingTemperature: 44'C(x2'C) � J Y Z O (/) U)
Open Circuit Voltage-Vec(V) 43.9 44.0 44.1 44.2 443 TempieraturecoefficientofP,,,,,t: -0-25%/'CLL
�- LL
ShortCircuitCurrem-4c(A) T 10.49 1052 1055 10.58-~-10.61 TemperaturecoefficiettofVQ;. 024%/°C 0 ...I 0
t
Power Density(W/sq ft) 19_.15 19.41 19.68 19.94 2021 Temperaturecoefficientof., 0.04%/°C g z O 0 U-)
Z
'�'%4 �' --'--�'--- __^----- -'T- The temperaturecoefficients stated are hnearvalues
-ERIE
a „mi Panel Efficiency(%) 20.6 20.9 21.2 21.4 21.7 Q C:)
J
O =
: , . . „ . CO F-- O
P ., (WP) 274 278 282 286 289 r LOW LIGHTBEHAVIOUR N
Power Dut ut-P ES =._ .__- ` -- - � 0
f- NomnalPowerVoha Voltage- TypicallowirradianceperformanceofmoduleatSTC: r' D
g ,.(V) 34.6 35.0 35.2 35.6 35.9 9 0
g Nominal Power Current-I,(A) 7.93 7.96 8.00 803 8.06 �
y
solar
Z
Open Circuit Voltage-Ve,M 414 41.5 41.6 41.6 41.7
inter ShortCircuitCurrent-IEXPERIENCEc(A) 8.47 8.50 8.52 8.55 8.57
s
ValuesatstandardtestmldniDns(SfCalrmAMTS,irradance1075W/sgft(ODOW/matmperaWm77F(2SCibasedonapmduUmn -
�
REE � spreAWthatol&wxeofPH,Va&L,±3)61NtNnmvettcl3s Nwdrendieopatgtepmwm(NMGTarmsAMl5.rAm - - - e - - -
• • d 8MWftnl.tenp-' 6TFFYvibdspeed33fts(m/s)'WhereaIndrtestbrar*Wpmeda (PSTCbw _ irae(W/W) V
• SHEET NAME3 . 0 P1RoT--,-r7r
-REC Group Is an International pioneering solarenergy company dedicated to empowering
consumers with dean,affordable solar power in order to facilitate global energy transitions. :;r RCC SPEC SHEET
WP 2020
l l Committed to quality and innovation.REC offers photovoltaic modules with leading high quality.
backed byanexcepttorallowwaranty claims rate ofiessthan 100ppm.Founded inNorwayin1996, wwwrecgroup,co
POWER WINNER ; REC employs.2000 people and has an annual solar panel rapacity of 18 GW.With over 10 GW 0 •0 SHEET SIZE
��. Instal worldwide,REC's empowering mare than 16 million people with clean solar energy REC'SIBLE
PERFORMANCE
_. . r ` `.j ' Group is a Bluestar Elkem company YAth headquarters in Norway,operational headquarters in ;_` �c a ANSI B
1 t ; Singapore,andregianalbases)nNorthAmenca,Etao e,amxiAsla-PaOc.
SHEET NUMBER
PV-6
f
1
1 SoLARMOUNT .. UNIRACSUNRISETERRACE,NY 11752
-
1
/ , ,• •1 1, I 1 •. I• •I I I I I
OPTIMIZED COMPONENTS t
I I ' III I I "'• ' ' ' '' I '' ' INTEGRATED BONDING&PRE-ASSEMBLED PARTS
• 1 • •i ,. , 1 • , 1 ,• •, 1 I Componrints are pie-assembled and optimized to reduce installation steps and save �3-
labortime,Ournow grounding&bonding process eliminates copper wire and grounding INTEGRATED BONDING
1 I• 1 .' I. 1 I I• `. •I ', '1 1 •1 1 .I 1•, straps or'bondingjumpers to reduce costs.Utilize the microinverter mount witha wile MIDCLAMP
management clip for an easier installation.
I I• . I , •I •I I , . I VERSATILITY
END
;, cAPs ONE PRODUCT-MANY APPLICATIONS �0
orient tibmt modules flush to the roof a at a desired tilt angle. Change module INTEGRATED BONDING ===
orientationto portrait or landscape while securing a large variety of framed modules on SPLICE BAR
flat,lova
.1 SPLICE
steep pitched roofs.Available in mill,clearand daikanodi ed rinishes --_
to outperform your projects financial and aesthetic aspirations.
AUITOMATED DESIGN TOOL
®I DESIGN PLATFORM AT YOUR SERVICE
Creating It bill of materials is just a few clicks away with U-Builder,a powerful online e INTEGRATED BONDING
j too[that hreamlinesthe process ofdesigningacode compliant solar mountjngsyskem, 0 L-FOOTW/T-BOLT
Save limn{by creatinga user profile,and recall preferences and projects automatically t
when yo
Login:Youwillenjoytheabifilytoshareprojectswill]customers;there"sno
need to.p1,ipt results and send to a distributor,just click and share.
PROJECT
1 4
FRONT ' INTEGRATED BONDING
TRIM " MICROINVERTER MOUNT w/
1 ' • x. WIRE MANAGEMENT •
•
011UL2703SYSTEM
BONDING&GROUNDING •MECNANICALLOADING •
ORECtASSIADATION
S
/ ®fesa.w; d
C:
1 1. UNIOAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT _ . _ •
r.:
. . r„�' �-�� �If;jay �. t.�.� —
-_ r_ ,� a � •
R - •
1 1 . I 11M N411 I.M11112I UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT
I I I I I I I I II, I I I I EXPERIENCE QUALITY EXCELLENCE i9ARRANTY TOOLS DOCUMENTACON
TECHNIEAL SUPPORT CERTIFIED QUALITY PROVIDER. BANKABLE WARRANTY
Ur irac's td6nical support team is dedicated to answering Uniiac is the only PV mounting vendor with ISO certifications Dori t leave your project.to chance,Unirac has the financial SHEET NAME
questions I& addressing issues in real lime- An online. for 90019015 14001:2Q15 and OHSAS 180012007, strength to Irack our products and reduce your risk Have peace
library. of documents including engineering reports, which means we deliver the highest standards for)it, of mind knowing you are receiving products of exceptional SPEC SHEET
FAST INSTALLATION. SUPERIOR AESTHETICS stamped T4etters and technical data sheets greatly form, and function,These certifications demonstrate our quality.$OLARMOUNT is covered by a twenty five(25)yearsimplifies your permitting and project planning process. excellence and commitment to first class business practices. limited p{oductwananlyandafrre(5)yearlimitedfinishwarranty.
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIItI1111111111IIIIIIIIIIIIIIII111111tiIIIlIIIII11IlII1111111111111111111111III11111111111111111111111111IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII .
NSI B
OPTIMIZED COMPONENTS VERSATILITY DESIGN TOOLS • QUALITY PROVIDER PROTECti YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLQICF AND A SUPERIOR SUPPLY CHAIN
SHEET NUMBER
a
HL
Pz.
I-IARVESTE� ER o Pz
HARVEST POWER LLC
stru ctural structuraI 2941 SUNRISE HIGHWAY ISLIP
ENGINEERS ENGINEERS TERRACE,NY 11752
TEL:(801)989-3585
June 6,2020 Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. —nebsf .harvest owernet
Landscape-PV Panel long dimension is parallel to ridge/eave line of roof and the PV
Unirac panel is mounted on the long side.
1411 Broadway Blvd.NE Portrait-PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel : �0
Albuquerque,NM 87102
is mounted on the short side. : .,
Attn.:Unirac-Engineering Department
Components and Cladding Roof Zones:
Re:Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail The Components and Cladding Roof Zones shall be determined based on ASCE 7-05,ASCE 7-10&7-16 Component and --;7
v sCd
Cladding design.
DESCRIPTIO E REV.
PZSE,Inc.-Structural Engineers has reviewed the Unirac SOLARMOUNT rails,proprietary mounting system constructed s' 1a1512021 0
Notes: 1)U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not
from modular parts which is intended for rooftop installation of solar photovoltaic(PV)panels;and has reviewed the U- include roof capacity check,
builder Online tool.This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail,SOLARMOUNT 2)Risk"Category II per ASCE 7-16.
STANDARD rail,and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information,data and
3)Topographic factor,kzt i5 1.0.
analysis contained within are based on,and comply with the following codes and typical specifications: 4)Array Edge.Factor Ye=1.5
1. Minimum Design Loads for Buildings and.other Structures,ASCE/SEI 7-05,ASCE/5EI 7-10,ASCE/SEI 7-16 5).Average parapet height is 0.0 ft.
2. 2006-2020 New York State Building Code,by International Code Council,Inc and New York State Department of 6)Wind speeds are LRFD values.
State. 7)Attachment spacing(s)apply to a seismic design category E;or less.
3. 2006-2020 New York State Residential Code,by International Code Council,Inc and New York State Department
of State. Design Responsibility:
4. 2006-2018 International Building Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 2017. The U-Builder design software is intended to be used under the responsible charge of a registered design professional
S. 2006-2018 International Residential Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 where required by the authority having jurisdiction.In all cases,this U-builder software should be used under the PROJECT NAME
2017. direction.of a design professional with sufficient structural engineering knowledge and experience to be able to:
6. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels,NovemberEvaluate whether the U=Builder Software is applicable to the project,and (� p0
1,2012 by,ICC-ES. O
r
® J
Understand and determine the appropriate values for all`input parameters of the U-Builder software. W 0
7. 2015 Aluminum Design Manual,by The Aluminum Association,2015 N =
r O J �_
Followingare p This letter certifies that the Unirac SM SOLARMOUNT Rails Flush,when installed according to the U-Builder engineering r O
typical specifications to meet the above code requirements: O
report and the manufacture specifications,is in compliance with the above codes and loading criteria. W } -- W 0
Design Criteria: Ground Snow Load=0-100(psf) J W Z O 07 (A
Basic Wind Speed=85=190(mph) This certification excludes evaluation of the following components: m < 0 O
V-
Roof Mean Height=0-60(ft) 1) The structure to support the loads imposed on the building by the array;including,but not limited to:strength 0 _J J Cn 0
Roof Pitch=0-45(degrees) and deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects Z O 0 O Z
Exposure Category B C&D O = O J ?�
P g rY= of snow accumulation on the structure. M O
2) The attachment of the SM SOLARMOUNT Rails to the existing structure. `— 0
Attachment Spacing: Per U-builder Engineering report. O O
3) The capacity of the solar module frame to resist the loads.
Cantilever: Maximum cantilever length is L/3,where"L"is the span noted in the U-Builder online Z =
tool. This requires additional knowledge of the building and is outside the scope of thecertification of this racking system. Q Q
Clearance: 2"to 10"clear from top of roof to top of PV panel. OF N��,
If you have any questions on the above,do not hesitate to call. FZq y0
Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation. 0,
CD F�`� SHEET NAME
Prepared by:
PZSE,Inc.—Structural Engineers r= w SPEC SHEET
Roseville,CA Z
� PO �31 aPZ SHEET SIZE
1369'
1478 Stone Point Drive,Suite 190, Roseville,CA 95661 1478 Stone Point Drive,Suite 190, Roseville,CA 95661 AROFESSIONP� ANSI B
T 916.961.3960 F 916.961.3965 W www.pzse.com T 916.961.3960 F 916.961.3965 W www.pzse.com " "
Experience Integrity Empowerment
11 X 17
Experience i Integrity I Empowerment p l g•fi' � p
SHEET NUMBER
PV-8